View Bid Results For Electronic Communication Measuring And Testing Instrument Tenders

We found 81 Bid Results related to electronic communication measuring and testing instrument tenders. You can find Contractor details who won electronic communication measuring and testing instrument tenders along with contract details in Bid awards announcements section.

Filters
Stage
51
19
11
Tender Publishing Platform
2
79
State / UT
21
14
13
10
7
5
5
4
3
3
3
2
2
2
1
1
1
1
1
1
1
1
Contract Value
32
9
19
21
Publish Date
1
0
0
0
0
Sector
13
22
11
10
7
6
6
5
5
3
2
2
1
1
Ownership
4
48
13
10
10
Within keyword
Active filters:
Showing 1–2 of 81 tenders matching your filters
1.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
2.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
3.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
4.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
5.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
6.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
7.
Educational and Research Institute #10680797 Price Bid
supply of tool machinery goods- 1 Connecting screw driver 2 Neon tester 3 Insulated combination pliers 4 Electrician knife 5 Soldering Iron Changeable bits 6 De- soldering pump 7 Soldering Iron 8 Optical Drives 9 Post error debugging card 10 PCI slot Testing tool 11 Network Management Software 12 Wireless Network Adapter 13 Router 14 LAN Cards 15 WI-FI LAN Card 16 Power Meter 17 Media Convertor 18 24 port UTP jack panel 19 NVR 20 POE adapters kit 21 IP Camera Outdoor 22 Analog camera with dvr 23 SMPS 24 Blu-Ray driveand player Dell/ hp/ toshiba 25 Digital Camera 26 Network storage 27 Card Reader 28 SMPS Trainer kit 29 Foot rule steel tape 30 Steel Measuring Scale 31 MARKING KNIFE 32 Try Square 33 Bevel Square 34 Carpenter marking gauge 35 Carpenter mortise gauge 36 Hand Saw 37 Metal smoothing plane Anant 38 Screw driver 39 Contraction measuring scale 40 Wi Fi Router 41 Switch 42 DVD or Blu-Ray Writer 43 Network Rack 44 Screw Driver Set 45 Mini Dongle for Bluetooth devicesConnection 46 Patch Panel 47 Punching Tool 48 Tally 49 Box drawing instrument 50 Protractor celluloid 51 Scales plotting box wood 6 metric scales 52 Set square transparent 53 Set square celluloid 54 T-Square 55 Template- Architects and builders 56 Telescopic Alidade 57 Levelling staff straight pieces 58 Transit Theodolite with stand with all accessories 59 Digital theodolite 60 Instrument for total station 61 DLP projector 62 First aid box 63 Screen for projector 64 Air conditioner 65 Document Camera Visualiser 66 Smart board-inter active board 67 Measuring Steel Tape 68 Combination Plier Insulated 69 Screw Driver Insulated 6mm X 150 mm 70 Electrician screw driver thin stem insulated handle 4mm X 100 mm 71 Heavy Duty Screw Driver insulated 72 Electrician Screw Driver thin stem insulated handle 73 Punch Centre 74 Knife Double Bladed Electrician 75 Neon Tester 76 Steel Rule Graduated both in Metric and English Unit 77 Hammer cross peen with handle 78 Connecting screwdriver 79 Neon tester 500 V. 80 Screw Driver Set 81 Soldering iron 82 Electrician knife 83 Tweezers 84 Digital Multimeter 85 Soldering Iron Changeable bits 86 De- soldering pump electrical heated manual operators 87 Precision set of screw drivers 88 Precision set of screw drivers 89 Precision set of screw drivers 90 Tweezers Bend tip 91 Steel measuring tape 92 Tools maker vice 93 Crimping tool pliers 94 Magneto spanner set 95 File flat second cut 96 File flat smooth 97 Plier - Flat Nose 98 Round Nose pliers 99 Hammer ball pen 100 Allen key set Hexagonal set of9 101 Tubular box spanner set of 6Nos 102 Magnifying lenses 103 Continuity tester 104 Hacksaw frame adjustable 105 Chisel Cold Flat 106 Hand Drill Machine Electric with Hammer Action 107 Bench Vice 108 Bench Vice 50 mm 109 DC Regulated Variable Programmable DC Power Supply 110 LCR meter Digital Handheld 111 Analog multimeter 112 Clamp meter 113 Dimmer starter 114 Autotransformer 115 Milli Ammeter AC 116 Op Amp trainer 117 Digital IC Trainer 118 Digital IC Tester 119 Digital and Analog Bread Board Trainer 120 POWER ELECTRONICS TRAINER with at least 6 nos of onboard applications 121 Electronic circuit simulation software with 6 user licenses 122 Different types of electronic and electrical cables connectors sockets terminations. 123 DSO colour 124 PAM PPM PWM trainer kit 125 AMFM Commercial radio receivers 126 Sensor trainer kit containing Various sensors like Thermocouple RTD Thermocouple  load cell strain gauge LVDT smoke sensors speed sensor Limit Switch Photo sensors Optocouplor Proximity Sensor 127 Fiber optic communication trainer 128 Seven segment DPM 129 LCD based DPM 130 SMPS of different make 131 UPS trainer 132 Mobile phone Trainer 133 Cell phone power source with charger chords for different cell phones 134 LCD TV Trainer kit 135 LCD TV 136 LED TV Trainer kit 137 LED TV 138 Home theatre system 139 Solar Training Kit Simulator 140 LED lighting system 141 Trammel 142 Steel Rule with metric British graduation 143 Compressor unit 144 Try Square 145 Pocker. 146 Caliper inside spring type 147 Mallet. 148 Caliper hermaphrodite spring type 149 Carrier for mounting components such as PB relay boxes. 150 Caliper outside spring type 151 Aviation Snips straight Cut 152 Cut section model for pneumatic components 153 Divider spring type 154 Planishing hammer. 155 Scriber 156 Centre Punch 157 Screw driver 158 Depthmicrometer. 0-25 mm 159 Stake grooving. 160 Hammer ball peen With handle 161 Comparators Gauge - Dial Indication with Stand and Bracket 162 Hammer ball peen With handle. 163 File flat - second cut 164 Engineer s try square knife- edge 165 File flat smooth 166 File half round second cut 150 mm 167 Vernier Bevel protector 168 Carbide Wear Block 169 Carbide Wear Block 170 Dot punch 171 Spirit Level metal Type - 2 172 Arm strong type tool bit holder 173 Combination Set 174 Arm strong type tool bit holder 175 Arm strong type tool bit holder 176 Stillson wrenches 177 Micrometer inside with extension rods 178 Vernier caliper 179 Adjustable pipe chain tonge to take pipes 180 Adjustable spanner 181 Screw pitch gauge Metric 182 Surface plateC.IGranite with Stand and Cover 183 Marking table Mild steel 184 Universal scribing block 185 V-Block pair with clamps 186 Punch letter set 187 Portable hand drill Electric 188 File knife edge smooth 189 File feather edge smooth 190 File triangular smooth 191 File round second cut 192 File square second cut 193 File flat second cut safe edge 194 File half round second cut 195 File round bastard. 196 File hand second cut 197 File card 198 Oil Can 199 Wooden handle forged Soldering Iron copper bit 200 Blow Lamp 0.50 liters. 201 Spanner adjustable 202 Double Ended tubular Box spanner set with Tommy bar 203 Glass magnifying 204 Clamp C 205 Hand Reamer set Tapar pin straight flute 206 Machine Reamer parallel Helical flute 207 Scraper flat 208 Scraper triangular 209 Scraper half round 210 Pipe wrench 211 Adjustable pipe die set BSP 212 Machine vice - Swivel Base 213 Machine vice - Swivel Base. 214 Sleeve drill Morse 215 Vice bench 216 Wing compass 217 Power tools for fastening 218 Different Profile gauges Plate type - For demonstration 219 Knurling tool Diamond 220 Knurling tool straight 221 Knurling tool Diagonal 222 Indexable boring bar with inserts 223 Machine maintenance mannual for Lathe Pedestal grinder Drill machine Power saw 224 Temperature gauge 225 Dowel pin straight 226 Standard Tap screws 227 Lapping plate 228 Caps screws 229 Drill gauges 230 Cast Iron Globe Valve Flanged type 231 C.I. Sluice Gate valve flanged type 232 Stop cock 233 Slip-on Forged steel Flange 234 Pipe threading die with handle 235 Pulleys for V-belt or Flat belt 236 V-belt and Flat belt 237 Packing gasket 238 Washer clutch keys jib cotter circlip 239 Bearing different types 240 Lifting sling 241 Bearing extractor 242 Pulley extractor 243 File half round bastard 244 REFRIGERATOR ( 365 LTR ) DOUBLE DOOR 245 GAS TANDOOR WITH SKEWER ROTI SET ( 12 SKEWERS ) COMMERCIAL 246 BAIN MARIE 2 PAN WELL 55.5 X 70 X 20 CM 247 CHINESE GAS BURNER DURA STEEL 60 X 24 X 30 248 SALAMANDER AVON REFRIGERATION 600 X 510 X 550 MM 249 ELECTRONIC GEYSER 25 LTR( HAVELLS, ADONIA )DIGITAL TYPE 250 DOUGH KNEADING MACHINE ( 5KG CAP )1000 WATT, STAND MIXER 251 WATER BOILER ( ELECTRICAL 15 LTR)2000 WATTS 252 MIXER CUM GRINDER FOOD PROCESSOR 1 NOX 1000 WATT,WITH 7 ACCESSORIES 253 WOK CHINESE KADAI 16 DIA METER 254 PRESSURE COOKER ( 5 LTR ) CAP 255 EGG CUTTER STAINLESS STEEL 256 STEAK HAMMER ALUMINUM 257 MS CUPBOARD INTERIO 2 DOOR WITH 3 SELVES 7 X 3 X 3 258 HAND BLENDER 250 WATT 259 SIZZLER PLATES ( 17-18 DIA) HEAVY FINE QUALITY 260 COFFEE URNS , ( 40 CUP CAPACITY) 261 CHINESE CHOPPER 262 MS CHOPPER 600WATT 263 KITCHEN KNIFE, BIG CARTINI 8 BLADE 264 VEGETABLE KNIFE 13 CM BLADE, MEYER CERAMIC KNIFE 265 BREAD KNIFE 8 BLADE 266 PASTA MACHINE , 150 WATT 267 WATER PURIFIER REVERSE OSMOSIS 6.5 LTS UV + UF 268 SODA MAKER MACHINE HEAVY DUTY INDUSTRIAL MODEL KVR - 8 FLAVOR 269 ESPRESSO MACHINE COFFEE GRINDER 1300 WATT 270 MINIBAR FRIDGE 271 LED 42” HD DISPLAY 272 MUSIC SYSTEM WITH DVD PLAYERS CONCEALED SPEAKER, 5.1 CHANNEL 273 ELECTRIC OVEN 20 LTRS (IFB, WONDER CHEF,HAVELLS) 274 DISPLAY FOOD CABINET OSHAM SLIDING DOOR ,814X 641 X 831 MM W X D X H 275 ROOM SERVICE TROLLEY HOME CENTRE MONTOYA TYPE 276 CARAFE BOROSIL SMALL WITH STRAINERS, 350 ML 277 CARAFE BOROSIL LARGE WITH STRAINERS , 700ML 278 SOUP FLASK TERMOSTEEL ( 500 ML ) 279 WATER FLASK THERMOSTEEL FLIP LID FLASK 1000ML SILVER 280 PASTA TROLLEY GOLDEN LINE 4 CASTOR WHEEL 281 EPABX SYSTEM + AVS MACHINE S- TECH CS432, 4 MAIN TRUNK LINES & 32 EXTENSION 282 SAFE DEPOSIT LOCKER / FORTE 40 BIOMETRIC SAFE 283 UMBRELLAS , CITIZEN 3 FOLD 284 STEEL CUPBOARD WITH UNBREAKABLE GLASS , INTERIO 4 SHELVES 7.5 X 3 X 2.5 285 FRIDGE WITH CABINET 275 LTR 286 VACUUM CLEANER WET & DRY 287 WASHING MACHINE 8KG FULLY AUTOMATIC 5 X 1400 RPM , INBUILT HEATER 288 WATER HEATER 25 LTRS HSE-SES , 2000 WATT 289 CARPET EXTRACTOR, CARPET CLEANER MACHINE 1100 , W PRO E X 25 290 HIGH PRESSURE JET CLEANER , KK PWIN 165 1800 WATT , 165 BAR 291 LUGGAGE RACK MINT WOOD H 27.5 X W 28.5 X D 12.8 292 HEAVY BOTTOM PAN 10 LTR NON STICK CANEROLI 40 CM 293 COOKER ( 2 LTR ) CLASSICS 2L ALUMINUM 294 MANDOLIN GRATER ADJUSTABLE SS 4 BLADES WITH HANDLE 295 PROBE THERMOMETER ( 75 - 100 DEGREE CELCIUS ) ST 9283B LCD , DIGITAL MULTISTEM THERMOMETER 296 CAKE STAND ( SS ) 13 TOP 297 HEAT PROOF GLOVES GRIPWELL KELVES PALM LEATHER HEAT RESISTANT GLOVES 298 GRINDING STONE FINE GRINDER STONE 10 299 PIZZA CUTTER STAINLESS STEEL 300 COOKIE CUTTER ( 5 SHAPES ) ALLAMWAR 12 PCS STAINLESS STEEL CUTTER SET 301 SANDWICH GRILLER / TOASTER SW X 400 700 WATT ( 302 JUICER MACHINE PHILIPS HR 1863/20 , 2 LTR 303 ROLLING BASE WOODEN 10 304 FRYING PAN NON STICK GRANITE FRY PAN ( 280 MM) BLACK 305 FRYING PAN LARGE NON STICK FRY PAN 240 MM0 306 CLEVER STAINLESS STEEL 2 IN 1 VEGETABLE SCISSORS 307 Steel rule 308 Outside spring caliper 309 Inside spring caliper 310 Hermaphrodite caliper 311 Divider spring 312 Centre Punch 313 Hammer 314 Cold chisel flat 315 File flat bastard 316 File flat 317 File flat smooth 318 Screw Driver 319 Scribing blockuniversal 320 Screw driver heavy duty 321 Spindle blade screw driver 322 Solid parallels in pairs different sizes in Metric 323 Oil stone 324 Punch letter set 325 Punch number set 326 Drill Chuck 327 File Half round 328 File triangular smooth 329 Reamer 330 Reamer adjustable 331 Tool bits holder Armstrong R.H. 332 Table chuck 333 Machine vice 334 Compound angle vice standard sine 335 Universal Machine Vice 336 Shaper tool holder turret type to suit the machine 337 Base chuck forslotter to suit the machine 338 Milling Cutter Side and face cutter 339 Milling Cutter Side and face cutter Adison 340 Milling Cutter Adison 341 Milling Cutter -Side and face cutter adison 342 Milling Cutter - Double Angle Unequal. adison 343 Milling Cutter - Double Angle Unequal. adison 344 Milling Cutter - Single Angle.. adison 345 Milling Cutter - Slitting Saw Cutter adison 346 Milling Cutter - Slitting Saw Cutter. adison 347 Milling Cutter - Shell End Mill.Parallel Shank end mills adison 348 Milling Cutter - Parallel Shank end mills. adison 349 Milling Cutter -mills. Parallel Shank end mills.. adison 350 Milling Cutter - Parallel Shank end mills… adison 351 Milling Cutter - Parallel Shank end mills.... adison 352 Milling Cutter - T Slot Cutter with Parallel Shank adison 353 Micrometer outside. 354 Micrometer depth gauge 355 Digital micrometer 356 Vernier Caliper 357 Direct reading vernier caliper 358 Combination set 359 Vernier bevel protractor 360 Telescopic gauge 361 Centre punch 362 Divider spring joint 363 Caliper odd leg spring joint 364 Wrench adjustable 365 Spanner double ended 366 Pipe wrench 367 Plumbing hammer weight 368 Four way reversible valve 369 Tape measuringgraduation in mm 370 Voltmeter ACDC portable precision grade Digital Panel board type 371 Rule steel 372 Drawing Board 373 Easel a Type stand 374 Hack Saw with Frame 375 Chisel Knife 376 Chisel Knife- 8mm 377 Chisel Knife- 10mm 378 Chisel Knife 20mm 379 Chisel Knife- 30mm 380 Diamond Glazier Knife 381 Paint Tin Opener 382 Shave Huck Knife 383 Glider Knife 384 Paint Burner Acetylene Gas 385 Screw Driver 386 Mild Steel Panels 387 Sink Stainless steel 388 Suction feed spray gun with accessories 389 Infra red lamp 390 Pneumatic Polishing Machine with Pads 391 Pipe vice 392 Pipe wranch 10 393 Pipe wranch 16 394 flat file- smooth finish 395 Circuler cut file 396 Raft cut 397 Pipe dai set metric Inches 398 Gun Spray with Gravity Feed Cup with Complete accessories with Complete accessories 13ltr 399 Gun Spray with Gravity Feed Cup with Complete accessories.. 400 Conventional Spray Gun For Pressure Feed 401 Pencil Hardness Tester 402 Air Compressor single Phase 1 HP 403 File - Flat - Bastard 404 File - Flat - Safe Edge 405 Cooling tower 406 File flat roughdouble cut 407 File half round fine double cut 408 File round finedouble cut 409 File flat fine double cut 410 File square finedouble cut 411 File triangular fine double cut 412 Try square 413 Divider spring joint 414 Caliper spring joint in side 415 Caliper odd legspring joint 416 Hammer ball pane 417 Cold Chisel flat and cross cut 418 Engineers rule 419 Tape measuring 420 Pliers flat nose 421 Line tester 422 Tweezers 423 Oil can 424 Surface Gauge universal 425 Bench vice 426 Hack saw tubular metal frame adjustable 427 Snip sheet metal straight nose 428 Snip sheet metal curved nose 429 Wooden mallet Nylon mallet 430 Round Punch 6mm 431 Round Punch 432 Round Punch 4mm 433 Screw driver plastic handle 434 Screw driver plastic handle Flat tip 435 Philips screw driver 436 Soldering ironexchangeable copper tip 437 Knife foldedstainless steel - 438 Tenon saw 439 Firmer chisel 440 Fire buckets 441 Quick couplesprocess tube adopter 442 Flaring tool set single type for tube. 443 Swaging tool punch type set of size for tube. external type for copper tube 444 Pipe cutter miniature for copper tube 445 Pinch of tool for copper tube 446 Ratchet spanner 447 Capillary plug gauge 448 Piercing pliers 449 Spanner double ended 450 Wrench adjustable 451 Wrench adjustable length 250mm 452 Valve key handleTreated as consumable 453 Hollo Punch hole for cutting gasket 454 Scissor gasketcutting stainless steel 455 L-Allen key 456 T-Allen key set 457 Pipe cutter withbuilt in reamer and space cutter for copper tube 458 Lapping plate 459 Hammer ball peen 460 Tap set withmatching drills 461 Tap set withmatching drills V to 462 Piercing Valve 463 Feeler gauge 464 Tape measuringgraduation in mm 465 Ammeter ACDCportable precision grade Digital Panel board type 466 Multi meter digital type 467 C.R.O Single beam 468 C.R.O Dual trace Double beam 469 A.F.O Oscillators 470 Pressure gauge 471 Compound gauge Digital type 472 Electronic leak detector 473 Sling psychro meter mounted on aluminum back 474 Stop watch 475 Multi meter 476 Sensor thermometer digital 477 filler guage 478 Wire gauge 479 Dial thermometer 480 Compressors testers for small hermetic compressors 481 Precision set of T5 T6 T7 screwdrivers- 482 Jacket stripper Coring tool for 500 series cable 483 Center conductor cleaner 484 Universal drop trimmer for RG 6/11 cables 485 F - connector tool for RG 6/11 cables 486 F connector compression tool for RG 6/11 cables 487 Solar Training Kit Simulator With built in meters for DCV DCA AC Multifunction Meter for ACI ACV Power Frequency Protection Circuits BS-10 terminals formaking the connection Single Dual axis tracking system Charge Controller PWM based MPPT Charging Stage Bulk Absorptions and Float 488 LED lighting system Measurement of Power Voltage Current Power Factor and Light output performance of different lighting products like LED CFL at variable inputvoltages 0 to 245V variable AC 489 PLC Systems with digital IP OP modules and software 6 Digital Inputs 24V DC. 4 Digital Outputs 24V DC 2K Words of memory 256 words of register. Powerful features like built in Floating Point Sub Routines etc.One RS232 C communication facility for PC interface. Three channels can be configured as follows Pulse width modulation output or Pulse train outputor High speed counter input. 490 Electronic Pneumatics Trainer kit 491 CRO dual trace 20 MHZ ( Component testing facilities ) 492 Steel wire Brush 50mmx150mm 493 carborundum 15 x 5 x 4 cm smooth 494 Straight edge gauge 2 ft. 495 Straight edge gauge 4 ft. 496 Surface gauge with dial test indicator plunger type i.e. 0.01 mm 497 Tachometer Counting type 498 Taps and Dies complete sets 5 types 499 Taps and wrenches - Metric 500 Temperature gauge 0- 100 deg c 501 Thread pitch gauge metric BSW 502 Timing lighter 503 Universal puller for removing pulleys bearings 504 V Block 75 x 38 mm pair with Clamps 505 Vacuum gauge to read 0 to 760 mm of Hg 506 Valve Lifter 507 Valve spring compressor universal 508 vernier caliper 0-300 mm with least count 0.02mm 509 Vice grip pliers 510 Voltmeter 50VDC 511 Hand Shear Universal 250mm 512 Solid Parallels in pairs Different size in Metric 513 Spanner Clyburn 15 514 Spanner T. flocks for 515 Spark lighter 516 Spark plug spanner 14mm x 18mm x Size 517 Spirit level 2V 250 05 518 Spring tension tester 519 Stake grooving. 520 Spanners socket with speed handle T-bar ratchet and universal upto 32 mm set of 28 pieces with box 521 Steel tool box with lock and key folding type 400x200x150 mm 522 Wire cutter and stripper 523 Car Jet washer with standard accessories 524 Chaser hard WV 9 to 40 T.P.I. set of 11 external. 525 Chaser hand WW 9 to 40 T.P.I. set of 11 internal. 526 Chisel 10 cm flat 527 Chisels cross cut 200 mm X 6mm 528 Circlip pliers Expanding and contracting type 15cm and 20cm each 529 Clamps C 100mm 530 Clamps C 150mm 531 Clamps C 200mm 532 Compression testing gauge suitable for diesel Engine 533 Connecting rod alignment fixture 534 Copper bit soldering iron 0.25 Kg 535 Cylinder bore gauge capacity 20 to 160 mm 536 DC Ohmmeter 0 to 300 Ohms mid scales at 20 Ohms 537 Depth micrometer 0- 25mm 538 Dial gauge type 1 Gr. A complete with clamping devices and stand 539 Dividers 15 cm Spring 540 Drift Punch Copper 15 Cm 541 Drift copper 10 x 15 12 mm 542 Drill point angle gauge 543 Drill twist 1.5 mm to 15 mm various sizes by 0.5 mm 544 230 V 25 watts Electric Soldering Iron 230 V 60 watts 545 Electric testing screw driver 546 Engineers square 15 cm. Blade 547 Engineers stethoscope 548 Equipment puncture in box 549 File flat 20 cm bastard 550 File half round 20 cm second cut 551 File Square 20 cm second cut 552 Files assorted sizes and types including safe edge file 20 Nos 553 Glow plug tester 554 Granite surface plate 1600 x 1000 with stand and cover 555 Grease Gun 556 Grover- 34mm. 557 6mm Grover 558 Growler 559 Hacksaw frame adjustable 20-30 cm 560 Hammer Chipping 0.25 Kg 561 Hammer copper 1 Kg with handle 562 Hammer Mallet 563 Hammer Plastic 564 Hand operated crimping tool i for crimping up to 4mm and ii for crimping up to 10mm 565 Hand reamers adjustable 10.5 to 11.25 mm 11.25 to 12.75 mm 12.75 to 14.25 mm and 14.25 to 15.75 mm 566 Hand vice 37 mm 567 High rate discharge tester cell tester 568 Left cut snips 250mm 569 Magneto spanner set with 8 spanners 570 Magnifying glass 75mm 571 Marking out table 90X60X90 cm 572 Multi Scan Tool 573 Multimeter digital 574 Oil Stone 15 cm x 5 cm x 2.5 cm 575 Oscilloscope 20MHz 576 Outside micrometer 0 to 25 mm 577 Outside micrometer 25 to 50 mm 578 Pat melting 579 Philips Screw Driver set of 5 pieces 100 mm to 300 mm 580 Pipe cutting tool 581 Pipe flaring tool 582 Piston Ring groove cleaner 583 Pliers side cutting 15 cm 584 Poker 585 Portable oil monitoring Indicator 586 Power Supply 0-12 v lamp 587 Radiator pressure cap 588 Rear axle assembly- gear box steering box assembly of the diesel engine 589 Right cut snips 250mm 590 Rivet sets snap and Dolly combined 3mm 4mm 6mm 591 Scriber 15 cm 592 Scriber with scribing black universal 593 Set of stock and dies - UNC UNF and metric 594 Shear Tin Mans 450 mm x 600mm 595 Sheet Metal Gauge 596 Soldering Copper Hatchet type 500gms 597 Sher Tinmans 300mm 598 Shovel 599 Ammeter 300A 60A DC with external shunt 600 Angle plate adjustable 250x150x175 601 Angle plate size 200x100x200mm 602 Arbor press hand operated 2 ton capacity 603 Auto Electrical test bench 604 Battery charger 605 Belt Tensioner gauge 606 Spanner ring set of 12 metric sizes 6 to 32 mm. 607 Blow Lamp 1 litre 608 AC alternator slip ring puller 609 Allen Key set of 12 2mm to 14mm pieces 610 Air blow gun with standard accessories 611 Alternator for tractor different type Mico , Bosch, tux 612 Hands file 20 cm. Second cut flat 613 Caliper outside spring joint 614 Caliper inside spring joint 615 Caliper odd-leg firm joint 616 Steel Rule 617 Scriber 618 Hammer ball peen 619 Centre punch 620 Prick punch 621 Divider spring joint 622 Safety goggles clear glass Good quality 623 Marking table CI 624 Bench vice 125 mm jaw 625 V - Block 626 Pliers flat nose 627 Micrometer Outside 628 Micrometer Inside 629 Vernier Bevel Protractor 630 Vernier Micrometer 631 Universal Dial Test Indicator - Plunger Type 632 Vernier Height Gauge 633 Plain Ring and Plug Gauge 634 Drill Twist Set 635 Reamer machine 636 Combination Drill Centre Drill 637 Tool Bit assorted sizes on holder 638 Chalk Board on mobile stand 639 Desk 640 Hand Chaser 641 Hand Chaser 642 Revolving Centrer to suit Lathe tailstock 643 Tool Cemented carbide assorted shaped External for steel turning 644 Machine Chase 645 Coventry Die head 646 Lathe Mandrels Diff. Types 647 Coventry Type Die Head Self opening 648 Stainless steel rule 649 Hack saw frame 650 File half round 651 File flat 652 Try square 653 Earth clamp 654 Electrode holder ESAB 655 Oxygen Gas Pressure regulator double stage ESAB 656 Acetylene Gas Pressure ESAB 657 CO2 Gas pressure regulator with flow meter ESAB 658 Argon Gas pressure regulator ESAB 659 First Aid box ESAB 660 Flash back arrester torch mounted ESAB 661 Flash back arrester cylinder mounted ESAB 662 Screw Driver 663 Screw Driver 664 Terminal screw Driver 665 Hammer Ball peen 666 Neon tester pencil bit type 667 Small crimping tools assorted 668 Spanner set DE 669 Screw driver set set of 5 670 File half round 2nd cut 671 File round 2nd cut 672 Soldering iron TONY 673 Neon tester 674 Spade 675 Sickle 676 Khurpa 677 Kasola 678 Trifali 679 Zindra 680 Dori (Nylon rope) 681 Wheel hand hoe 682 pH meter 683 Electrical conductivity meter 684 Flame photometer 685 Spectrophotometer 686 Atomic absorption spectrophotometer 687 Shaking apparatus 688 Distillation unit 689 Ammonia distillation unit (with heaters) 690 Gas connection 691 Sampling tools (augers) 692 Refrigerator 693 Gas cylinders with regulators 694 Gas cylinders with regulators 695 Gas cylinders with regulators 696 Incubator (with temperature control) 697 Infrared soil moisture estimation unit 698 Electric oven 699 Soil cores 700 Soil infiltratormeter 701 GPS system with mobile phone 702 Table top centrifuge 703 Auto Titrator 704 Battery charger
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
8.
Drinking Water Supply and Sanitation #10523073 Price Bid
Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities 2 Design, Construction, Supply of all materials, Erection and Commissioning of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities with all the civil,LT/HT panel room, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.6m wide, area approx 2000sqm),fiiling of earth if required]fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned)., staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement,sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost is inclusive of (Peak flow 24.11 MLD) (civil works). 3 INTERCEPTOR SEWERExcavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in manhole and SCC) 4 (a)0.00 to 1.50 m 5 (b) 01.50 to 03.00 m 6 (c) 03.00 to 04.50 m 7 Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete 8 (a)1.5 to 3 m 9 (b) 03.00 to 06.00 m 10 Same as item No. 3 but for open timbering (No timbering for depth <1.50m) 11 (a) 1.50 to 03.00 m 12 Timbering left in trenches (No timbering for depth <1.50m) 13 Open Timbering left in trenches (used timbering) 0-3m depth 14 Closed Timbering left in trenches(used timbering)0-3m depth 15 Closed Timbering left in trenches(used timbering)3-6m depth 16 Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 17 600 mm dia 18 700 mm dia 19 Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment600 mm dia pipe 20 01.50 - 0 3.00 m 21 03.00 - 04.50 m 22 700 mm dia pipe 23 01.50 - 0 3.00 m 24 Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. 25 (c) 03.00 to 04.50 m 26 Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. 27 (b) 01.50 to 03.00 m 28 Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) 29 Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement. 30 1200mm internal dia., 3.30m deep 31 1500mm internal dia., 4.95m deep 32 Extra for every additional depth of 1 m or part there of in following size of circular manholes. 33 1200mm internal dia., 3.30m deep 34 1500mm internal dia., 4.95m deep 35 Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge. 36 Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge. 37 Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. 38 Disposal of Surplus Earth as per direction of Engineer Incharge. 39 Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site 40 MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller) 41 Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge 42 Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge. 43 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) 44 Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329- 400 mm 45 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm) 46 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm 47 Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 48 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing 49 Sluice valve, Air valve chambers 50 Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 51 Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 52 Interception and diversion (I&D) Structure works 53 Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge 54 Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river) 55 Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.0.0 to 1.5 mtr. Depth do - in all kindes of soil 56 Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329- 400 mm 57 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia) 58 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work150 mm 59 Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 60 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing. 61 Sluice valve, Air valve chambers 62 Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 63 Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 64 E/M WORKS 65 STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) 66 A. Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.B. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (3 KL/H) with double cylinder having VFD for its operation , 1000 Lit. PVC tank for washing screw press machine. all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) 67 E./M. Works at MPS 68 Electrical Works 69 H.T.Panel( Comprising with 1 -I/C and 2 -O/G. (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 70 SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 71 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. (1set, included in STP costing) 72 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) (2 sets, included in STP costing) 73 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. (included in STP costing)3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) -60 metersTrench making and covering of trench in all respect.- 60 metersSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 sets11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 SqmTransformer:Suitable capacitywith Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (included in STP costing) -- 2 Nos. 74 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 75 LT Cable laying and jointing 76 Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 77 Earthing 78 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 79 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 80 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 81 Charges of Electrical safety Clearance 82 Expenditure on B&L Form, Challan etc. 83 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 84 STARTER PANEL 85 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 86 Mechanical Works 87 PumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 3110 lpmTotal Head= 16 M or as per designSpeed=980Quantity of pumps. 88 Guid Rail System 89 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set.(6 Sets, included in item no. 51.01) 90 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (6 Sets, included in item no. 51.01) 91 Main piping and Valves.Main piping and valves 200 mm dia delivery, 350 mm diacommon header line. 92 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 93 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 94 Motor Operated Sluice Valves 95 Sluice Valve 200 mm dia 96 Sluice Valve 350 mm dia 97 Reflux Valve 98 Reflux valve 200 mm dia N.B. 99 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . 100 200 mm, K9 delivery pipes for all six pumping plant 101 350 mm, K9 common header pipes 102 Specials like bend, tee, D Joint etc. 103 Nut Bolt, Washer Rubber packing etc 104 INSTALLATION, TESTING & COMMISSIONING 105 Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above. 106 Level Transmitter (For Hi-Lo cut-off & alarms) 107 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 108 Electro magnetic flow meter 109 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 110 E.O.T. Crane 111 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 112 Chequerred plate and guards 113 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 114 PAINTING 115 Painting of all pumps piping and valves with two coat enamel paint. 116 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 117 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 118 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 119 IPS Campus with Solar Panel and LED Light of 3 sets. 120 D.G. SET AND ACCESSORIES 121 SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developingat 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. (1 set, included in stp costing) 122 SITC of PLC Based Auto main failure (AMF) Panel forDG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.(1 Set, included in stp costing) 123 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.(2 Job, included in stp costing) 124 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. (2 Jobincluded in stp costing) 125 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. (1 Job, included in stp costing) 126 Providing and Laying cable for DG Set to Panel ( armored aluminium )-(1 Job, included in stp costing) 127 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. (4 Jobs, included in stp costing) 128 SCREENS AND GATES: 129 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 130 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at mid year peak discharge (1w+ 1s) 131 Packing and Frieght 132 Installation, Testing and Commissioning 133 AUTOMATION OF MPS 134 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 135 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 136 CE/UL certified intellignet Smart Energy Meter 137 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 138 160 AMP rating 139 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 140 CE/UL Certified Surge protector for control panel. 141 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. 142 Security Survillance IP Camera with recorder 143 Installation, commissiong & testing of above automation work 144 Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period 145 E./M. Works at IPS Dhampur 146 Electrical Works 147 H.T.Panel( Comprising with 1 -I/C and 2 -O/G .(panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 148 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 149 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) 150 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 151 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) 152 SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) 153 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV 154 Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. 155 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 156 SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 157 LT Cable laying and jointing 158 Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 159 Earthing 160 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 161 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 162 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 163 Charges of Electrical safety Clearance 164 Expenditure on B&L Form, Challan etc. 165 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 166 STARTER PANEL 167 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel) 168 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 169 Mechanical Works 170 Large PumpsThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 5750 lpmTotal Head= 40 M or as per designSpeed=980Quantity of pumps. 171 Guid Rail System 172 Guide rail system (Automatic coupling system) for 90 HP submersible pump setscomplete for above pump set.(3 Sets, included in item no. 94.01) 173 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (3 Sets, included in item no. 94.01) 174 Small Pumps 175 Thesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump=2500 lpmTotal Head= 17 MSpeed=980Quantity of pumps. 176 Guid Rail System 177 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. (2 Sets, included in item no. 98.01) 178 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (2 Sets, included in item no.98.01) 179 Main piping and Valves. 180 200 mm dia delivery for small pumps and250 mm dia delivery for large pumps, 350 mm diacommon header line. 181 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 182 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 183 Motor Operated Sluice Valves 184 Sluice Valve 200 mm dia 185 Sluice Valve 250 mm dia 186 Sluice Valve 350 mm dia 187 Reflux Valve 188 Reflux valve 200 mm dia N.B. 189 Reflux valve 250 mm dia N.B. 190 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing . 191 200 mm, K9 delivery pipes for small pumping plants 192 250 mm, K9 delivery pipes for large pumping plants 193 350 mm, K9 common header pipes 194 Specials like bend, tee, D Joint etc. 195 Nut Bolt, Washer Rubber packing etc 196 INSTALLATION, TESTING & COMMISSIONING 197 Installation & Commissioning of allPump set,Piping & Valves as mentioned in above @5% of supplied items. 198 Level Transmitter (For Hi-Lo cut-off & alarms) 199 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 200 Electro magnetic flow meter 201 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 202 E.O.T. Crane 203 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 204 Chequerred plate and guards 205 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 206 PAINTING 207 Painting of all pumps piping and valves with two coat enamel paint. 208 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 209 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 210 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 211 IPS Campus with Solar Panel and LED Light of 3 sets. 212 D.G. SET AND ACCESSORIES 213 SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. 214 SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. 215 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. 216 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 217 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. 218 Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ). 219 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm. 220 SCREENS AND GATES: 221 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 222 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge (working) 223 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge( standby) 224 Packing and Frieght 225 Installation, Testing and Commissioning 226 AUTOMATION OF IPS 227 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 228 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 229 CE/UL certified intellignet Smart Energy Meter 230 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 231 160 AMP rating 232 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 233 CE/UL Certified Surge protector for control panel. 234 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 235 Security Survillance IP Camera with recorder 236 Installation, commissiong & testing of above automation work 237 3 month trial run of automation work 238 Expenditure on Operation & Maintenance of IPS during 3 month Trial and Run Period 239 Expenditure onDiesel Consumption of IPS during 3 month Trial and Run Period 240 Expenditure on Electricity Consuption of STP, MPS & IPS as per actual UPPCL bill during 3 month Trial and Run Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Uttar Pradesh View Result →
9.
Water Resources and Irrigation #10512078 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation, Furnishing Of Existing Barrage Control Room At Gaula, Barrage, Haldwani, Uttarakhand Under National Hydrolog , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification. , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Gaula Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimumone Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
10.
Water Resources and Irrigation #10512072 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification, Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Under National Hydrology Project , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Condition System With Requisite Furniture And Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification Located At Adwa Barrage, Mirzapur , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Ramnagar Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
11.
Communications and Information Technology  #10457552 Price Bid
Supply Installation Testing Commissioning And Equipment For Gold Ornament Cluster Supply, Installation, Testing, Commissioning And Trail Run Of Machinery And Equipment For Gold Ornament Cluster Under Mse Cdp Scheme. , Gold Cluster Ornament , Supply And Installation Of Faceting And Milling Machine (Cnc Machine) For Bangles And Wedding Bands Double Head With Variable Speed Control, Computerizes Six Axis System. Specification: Number Of Head Horizontal & Vertical 02. Type Of Main Centre Universal 03. Number Of Axis (5+2) ‘X Longitude, ‘W D-Tilting, ‘Z Vertical For Depth, ‘R 360° Horizontal Rotary For Angular Position & Machining, ‘H Horizontal Spindle, ‘V Vertical Spindle, 04. Travel Of Axis ‘X Longitude 60 Mm, ? Rotating For Job - Continuous Rotary/Index, 2 To 400 Divisions, ‘W Tilting (Semi Rotary) Degree -40° To 90°, 05. Type Of Optional Accessories For Optimum Operation. Optional Accessories Can Be Fitted For Flat And Half Round Bangles And, Bands (Rings) 06 Milling Spindle Speed Horizontal (Servo Motor) Vertical (Hf Ac Built-In Motor With Pneumatic Tool Change Water Cooled Spindle). Min. 1000 Rpm To Max. 9000 Rpm, Min. 10,000 Rpm To Max. 60,000 Rpm ‘? Rotary,07. Spindle Motor Power Vertical, Horizontal, 1.5 Kw, 0.4 Kw,08. Electrical Supply 220V Ac / 50 Hz, 09. Total Required Electrical Load 3 Kva, 10. Air (Pneumatic) Supply Dry And Oil Free Air With 6 Bar / 87 Psi And 4 Cfm /120 Lpm Flow Rate, 11. Dimension (L X W X H) 94 X 97 X 156 Cm. 37 X 38 X 61 Inch.12 Floor Space Required (L X W X H) 155 X 161.5 X 156 Cm. 61 X 63.5 X 61 Inch,13 Net Weight With Standard Accessories 327 Kg Approx., 15 Shipping Dimension With Standard Accessories (L X W X H) Box-1 - 75 X 92 X 120 Cm. 29.5 X 36 X 47 Inch, Box-2 - 119 X 122 X 181 Cm. 47 X 48 X 71 Inch., Box-3 - 32 X 63 X 42 Cm. 12.5 X 25 X 16.5 Inch. To Include Additional Supporting Machine Tools And Materials. Fully Automatic And To Include Software Installation, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Udh - 701 Vekaria Make Or Its Equivalent. , Supply And Installation Of Bangle And Ring Turning Machine Specification: 1.5 To 3 Specification: Bangle Turning Machine (Without Any Accessories)- With Standard Inside Bangle Turning Socket - 1 Pc.- With Standard Outside Bangle Turning Mandrel - 1 Pc.- Bangle Turning Tool Holder - 1 Pc. Bangle Nylon Collets Set- Set Of 33 Inside Turning Collets (Size From 2” To 3”) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Or Its Equivalent. , Supply And Installation Of Bangle And Ring Profiling Machine 2 To 3 No.S 17 To No. 49 With Bangle Stretcher /Pep Tools. Specification: Combined Double Head (Horizontal And Vertical) *Simple To Calculate Divisions Up To 120 Parts*Robust Base With Mounting Holes For Hassle Free Operating*Dual Motor (1 For Each Head) (0.17 Hp/ 2800 Rpm)*Spindles (Rpm) - Horizontal – 5600 / Vertical – 6500* Motor 0.25 Hp* Machine Dimension 76X76x82 Cm, Bangle Nylon Collets With 1 Bangle Holder For Diamond Cut Faceting, Ring Nylon Collets With 1 Ring Holder For Diamond Cut Faceting, Ball Attachment, Half Ball Collets Set Of 6, Chain Attachment And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Model Sku: 16.0701 (Bangle Ring Turning Machine) Or Its Equivalent. , Supply And Installation Of Laser Engraving Machine 12000Mm/Sec, Cooling Systemspecification: Platform - Safety Enclosure, Operating Mode - Mopa Pulse Fiber Laser, Wave Length - 1064 Nm, Pulse Frequency - Upto 2000 Khz, Output Power - 20 Watt Mopa Pulse Fibre Engine, Focusing Optics (Nm) - 100, 163, 254, Cooling Capacity - Fully Air Cooled, Heat Sink, Profile Laser (Optional) - Visible, Red Beam Pilot Laser, Laser Safety Compliance - Fda (Cdrh), Csa, Ce.With High Speed Fiber Laser Marking Technology Marking/Deep Engraving /Cutting On Precious Metals, With Dust / Fumes Collection Unit.Pulse Fiber Laser (Mopa Engines) And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: 3802 Series Laser Marker With Rotary & Laptop Of Laser Star Make From Italy Or Its Equivalent. , Supply And Installation Of Cnc Router Machine With 3D Printer With Supporting Printing Material Specification: Jewelers Engraving 3-4 Axis With Zczb Wax Printer/ Stablizer /Struller/ Chemical /Computer Set /Heater Cleaning Tools/Back Up Ups. Molding Method - Mjp, Molding Size - 294*211*144 Mm, Printing Mode - Xhd:1200*1200*1600 Dpi:16, Dimension Accuracy - + 0.04 Mm/20 Mm, Power Supply - Ac 220-240 V, 50 Hz, 3 Kw, Overall Size - 1415*790*1160 Mm, Overall, Weight - 380 Kg, Package Size - 1700 *1000*1400 Mm, Application Software - 3D Print Data Support Format - .Stl/.Slc, Operation Environment - 18-28 ° C / 30-70 % Humidity And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. , Supply And Installation Of Digital Weighing Machine - Set Of 10 Machines With Calibration Set Up Specification: Weighing Capacity: 62 G, Resolution: 0.1 Mg, Calibration: External, Display Type: Clear Reverse Backlit Lcd Display, Standard Interface: Rs -232 C Repeatability: 0.1 Mg, Weighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: A&D Japan Or Its Equivalent. , Supply And Installation Of Ball Making Machine With Full Set Of Sheet Drawing Of Pipe Making, Soldering, Sheet Striping Machine, Hammering With All Standard Accessories Specification: Power: Single Phase, 220 V, Weight: 158 Kg, Dimensions: 45 X 76 X 106 Cm Suitable For Production Of Small To Large Sized Round, Long Oval, Long Barrel Shaped Balls From Strip Or Tube By Changing Dies, Size: 1.8Mm - 8 Mm, Ac Power 2 Hp Motor, 80-100 Balls Per Minute With Oil Pump, Weight 350Kg, Material Die Steel, Suitable For Production Of Balls Or Other Shapes Chain In Small Dimensions By Changing Dies From 0.60Mm Up To 2.00Mm, Ac Power 1 Hp Motor, 80-100 Links Per Minute With Oil Pump, Weight 300Kg. (Approx), High Grade Die Steel Material. With Separate Sheet Metal Drawing Machine Setup, To Manufacture Hallow And Solid Gold Ball Shapes, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Laser Welding Machine 130 Joule Capacity With 150 Joule Cap.Specification: Source Type - Nd: Yag (Flashlamp), Wavelength - 1064 Nm Output Power (Watts) - 60 W /80 W, Maximum Peak Power - 11 Kw, Pulse Frequency - 0.5 - 50 Hz, Beam Diameter - 0.05 - 2.00 Mm, Burst /Speed Welding - Optimized To Energy Values, Max Pulse Energy - 180 J, Pulse Performance Profile Technology - Exclusive Integrated Software, Soft Touch Resonator Technology - Beam Profile Technology (Optional), Supply Circuit - 120 V Or 230 V (+ 10 %)50/60 Hzfunctionality: 1. Automatic Energy Save Mode, 2. Integrated Preventive Maintenance Alerts, 3. Multi Language System Display, 4. 99 Memory Settings, 5. Preprogrammed Application Parameters Ceramic Cavity New Technology, 6. Inbuilt Cooling System Specially Designed For Jewelry Industry, And 7. Less Maintenance And More Efficient Power Supply Technology., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Workmake/Model: Laser Star Brand Pedistal/Stablizer Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. 10 Mm (3/8 Inch) Letter & Number Punch Set (0 To 9) & 27 Letters, Type Of Product: Punch, Weight: 995 G, Size: 10 Mm, Material: Carbon Steel, Usage: Professional I.E., On Gold And Silverand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries / Kravetto Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. Material Stainless Steel, Model Name/Number Devi: Embossing Dies, Weight 50 Gm Gross Weight 70 Gm, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/ Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes)Pattern Dimensions 3Mm - 50Mm, Material D2 D3, Usage/Application Bangle Ring Jewellery Making As Per Required Designs Quantity - 400 Pieces And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern Type: Round, Pattern Dimensions: As Per Requirements, Usage/Application: Coin Making, Material Stainless Steel, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polished, Hardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Ofgold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern: Type Square, Pattern Dimensions: As Per Requirements, Usage /Application: Coin Making, Material: Bronze And Hard Ss, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polishedhardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply And Installation Of Digital Vacuum Pressure Casting Gold Melting Machine Capacity: 2.4Kg, With Digital Display And Cooling System.Fully Automatic Casting Machine Brand/ Reiacetech Wax Mono Endura / Indigenous Furnace 6 To 8 Flask Capacity/Matrix Investment Mixer 5 Flask/ Steam Machine /Ultra / De-Waxing/Water Jet/Manual Wax Injector/ Tools /Materials For Casting/ Cylinders Powder / Stabilizer Set For All The Machine And Support Materials. Specification:Power: 11 .0 Kw, Frequency: 6 Khz, Ac Line, (50/60 Hz), 3 Phase:400 V + 10%, Melting Temperature (Max): 1300 ° C, Crucible Capacity: 3 Kg Au, Crucible Volume: 208 Cm3, Flask Size (Min): 87 Mm X 127 Mm, Flask Size (Max): 120 Mm X 300 Mm, Vacuum Pump: Included , Weight: 290 Kg (639.3 Lb), Dimensions: 70 Cm X 101 Cm X 135 Cm, Inlet Water Temperature: 35 ° Cfunctionality: Vacuum Casting Machine With Auto/Manual Technology Operating Process With High Pressure Vacuum Motor. Add On Machines For Pre Casting And Post Casting: Reiacetech Wax Injector From Italy Or Its Equivalent. Ingenious Furnace 6 To 8 Flask Capacity With 4 Side Heating Capacity. Indeginous Investment Mixer 5 Flask Capacity. Steam Machine For Gold Tree Cleaning, Manual Wax Injector Ultra Sonaic Machine, Steam De-Waxing Machine, Tool And Consumables For Casting Unit, Stabilizer Set, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Melting Machine With Digital Display And Cooling System Capacity: 2Kg With Digital Display And Cooling System, Two Models With Chiller From 50 Gm To 2 Kg, Melting Capacity / Rio Grande Melting Machine With Digital Display With Graphite Crucible Sets And 50 Gm To 500 Gm Capacity (2 Or 3 Qty Required) Specification: With Ceramic Based Crucible With Digital Thermocouple Heating Sensor Display Screen, Power - 440 V 3 Phase, Water Cooler - 35 Littre (In Built), Weight - 120 Kg, Dimensions - 36 X 30 X 45 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Refinery Machine 2Kg Charged Up To 6 Kg Per Day With Digital Display And Cooling System Should Have Excellent Thermal Insulation To Prevent Loss. Specification: Gold Refining Unit, Power Supply: 400 V / 3 Phase, Power: 0.3 Kw, Dimension In Mm: 1200 X 670 X 1120, Weight: 80 Kgs. To Have Low Running Costs, Fully Automated Process With Process Control And With Fumes Filter & Exhaust Filter And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Koras Refining Unit With Auto Stirrer Set Up With Acrylic Material Or Its Equivalent. , Supply And Installation Of Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed Specification: Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: High Pressure Hydraulic Die Cutting Machine From Hk Brand Or Its Equivalent. , Supply And Installation Of Mesh Chain Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of Box Chain Making Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of V-Chain Making Machine With Standard Accessories Specification: Motor: 0.50 Hp Pmdc Motor & Drive Speed Control Rpm 0 – 1500. 180 Wt. 1 Year All India Warranty. Table: Machine Cabinet Steel Mattel & Weight 49Kg. Electronic Panel: Dc Drive Full Electronic Panel• Sensor (Auto Cut)• Heater (37 Wt., Temperature 800O). Features: Automatic Machine For Venetian Chains, Variable Speed Controller, Forced Lubrications System With Oil Tank And Electronic Brake Sensor, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Best Indian Heavy Duty Machine/ Vekaria Brand Or Its Equivalent. , Supply And Installation Of 12 Pass Wire Drawing Machine With Full Set Of Standard Accessories Specification:Max. Wire Diameter (Guage/Mm) = 20/0.91 To 18/1.22.•Min. Wire Diameter (Guage/Mm) = 36/0.91 To 36/0.19.•Main Motor = 1.5 To 2 Hp.•Cooling Motor = 0.25 Hp.•Machine Weight =225 To 345 Kg. Heavy Duty Sturdy Metal Frame That Holds The Motor.•Transmission Drive.•Speed Control Drive.•Cooling Liquid Tank And Sprayer.•The Unwinding Reel.•The Motorized Winding Reel With Adjustable Clutch.•Steel Palermo For Longer Durability Of Machine. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent. , Supply And Installation Of Sheet And Wire Drawing Machine With Standard Accessories With Heavy Duty Motor Capacity And Auto Stopper Technology Specification: Wire & Sheet Rolling Mill For Gold & Silver • Roller Length 200 Mm X 100 Mm. • Heavy Duty Machine • Bronze Bushings • 5 Hp Electric Motor • Three Phase Power Supply • Hardened Ground Steel • Roller Mouth Openness: 20 Mm. • Weight 800 Kg, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent , Supply And Installation Of Laser Marking Machine Specification: Karat Mark: Laser Marker (20 / 30 W Power) Specification: Laser Power: 20 W-30 W, Laser Wavelength: 1064 Nm, Frequency Range: 20 - 120 Khz 1-600 Khz, Beam Diamter: 7+1 7 + 0.5, Format Supported: All Vector Files And Image Files (Bmp, Jpg, Gif, Tga, Png, Tif, Ai, Dxf, Dst, Plt), Scan Field: 100 X 100 Mm Scan Speed <<7000 Mm/S, Power Regulating Range: 10 -100 %, Cooling Method: Air Cooling, Operating Environment - 0° C - 40 ° C (Non -Condensing), Electricity Demand - 220 V (110 V)/50 Hz (60 Hz), Size & Weight - Around 24 X 17 X 15 In, Gross Weight Around 22 Kgs, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make /Model: Alpha Laser Marker (20/30 W Power) , Supply And Installation Of Xrf Machinemistral Sdd, Item Note: Xrf Karat Meter (Sdd) Stabilizer / Support Specification:Intended Use: Energy Dispersive X-Ray Measuring Instrument (Edxrf) To Determine Thin Coatings, Trace Elements And Alloys. Element Range Aluminium (13) To Uranium U (92) - Up To 24 Elements Simultaneously. Designs Bench Top Unit With Upward Opening Hood, Measurement Direction: From Bottom To Top, X-Ray Source, X-Ray Tube Micro Focus Tube With Tungsten Target And Beryllium Window, High Voltage Three Steps: 10 Kv, 30 Kv, 50 Kv, Aperture (Collimator) 4X Changeable: 00.2 Mm (7,9 Mils), Ø 0.6 Mm (23.6 Mils), Ø1 Mm (39.4 Mils). Primary Filter: 6X Changeable: Ni, Free, Al 1000 ?M (39.4 Mils). Al 500 ?M (19.7 Mils). Al 100 ?M (3.9 Mils), Mylar 100 Um (3.9Mils)Measurement Spot Depending On The Measuring Distance And On The Aperture In Use, The Actual Measurement Spot Size Is Shown In The Video Image. Smallest Measurement Spot Approx. 0.3 Mm (11.8 Mils) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Fisher Xrf Sdd Brand Or Its Equivalent. , Supply And Installation Of Assay Balance: 0.001 Mg Accuracy With Mettler Toledo Scale Je3002 G/M Gold Scale 3.200 With Digital Display. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232 C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Analytical Balance Machine With Digital Display With All Standard Accessories. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Precision Balance Machine With Digital Display With All Standard Accessories. Specification:Weighing Capacity: 62 Gresolution: 0.1 Mgcalibration: Externaldisplay Type: Clear Reverse Backlit Lcd Displaystandard Interface: Rs -232 Crepeatability: 0.1 Mgweighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of 50Gm, 100Gm, 200Gm, E2 Class Wire Weight With Display Attachment Item Note: 50Mg. E-2 Class Wire Weight With Nabl Calibration Certificate. Specification: Calibration Units With Stainless Steel Measuring Exact Weight Standards For Weighing Machines Block. Weights Intended To Ensure Traceability Between National Mass Standards (With Values Derived From The International Prototype Of The Kilogram) And Weights Of Class E2 And Lower. Class E1 Weights Or Weight Sets Shall Be Accompanied By A Calibration Certificate, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Tools And Equipment For Sampling Balling Pliers, Couplers, Scraping Tools, Tongs, Forceps, Rolling Mill Etc. For Complete Assay Set Up Please The Link As Provided Below, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Furnaces, Scrubbers, Parting Tray Etc. Item Note: For Hallmarking Full Setup Center Required. (3 Phase Power, Pollution Clearance Certificate Bis Approval Fee, And All Things) Specification: Annealing Furnace With 220V / Single Phase Along With Supporting Materials. Assay Supplies: Assay Laboratory Spare Parts And Consumables, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work For Complete Assay Set Up Please The Link As Provided Above Against Item No. 29 , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements..I)Cctv Cameras With Night Vision2 Megapixel Ip Cameras With Motorized Verifocal& Pixel Zoom ; Progressive Scan Cmos 1/2.8 Or 1/3Format; Focal Length 2.8 To 12Mm; Zoom Range – 4.2X Varifocal; Multiple Simultaneous Stream; Streams First Stream : Full Hd, 1~30Fps; 1280X720, 1~30 Fps; 704X576, 1-30Fps, Second Stream 704X576, 1~30Fps; 352X288 10~30Fps; Video Compression 32 Kbps ~ 16 Mbps, Support Cbr/Vbr; H.264 Version 3, High Profile Encoding And Motion Jpeg Format Support; 1920(W) X 1080(H) Or Higher Active Pixels; Built-In Ir With 2 Or More Epled; Sw Supported Digital Wdr ; Auto Blc; Sd Memory Slot Upto 32Gb Class 10; Minimum Illumination Icr Colour 0.1 Lux (F1.2 Agc On) B/W 0.001 Lux (F2 Agc On); Shutter Speed 1/25-1/10,000S ; Multiple Resolution 4Cif(704X576), Cif (352X288); 12Vdc / 24Vac / Ieee802.3Af Poe (Rj-45) Support; Supporting All Network Protocols (List The Supporting Protocols); 10/100 Base-T, I/O Audio Support, Audio Compression G.711; Multi-Level User Access With Password Protection; Ip Address Filtering; Https Encrypted Data Transmission; Ieee 802.1X Port-Based Authentication For Network Protection; Ip Address Filtering Https Encrypted Data Transmission; Operating Temperature -10 Deg C To +55Deg C,Onvif Compliant, 36 Months Comprehensive Warranty. Ce, Fcc, Emc & Rohs Certification; And Ul Certification For Core Adaptor Are Mandatory; Onvif Complaint Make: Cp-Plus/Cp-Unc-Tb21zl6s-Vmds27125/Panasonic/Pi-Spw 201Dl/Bosch/ Nti 50022-A3s. Integration Of Cctv System To The Central Server Unified Command Centre Solution Platform (Uccs) At District Police Headquarters Command Center(Dphcc) In Coordination With The Police Department / Designated Agencyand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of 32 Channel Network Video Recorder(Nvr) : Supply, Installation, Testing And Commissioning Of 32Ch Embedded 4K Nvr 4Sata Expandable Up To 40Tb, Audio Input & Output, Two Way Communication Supported, G7.11 Audio Format Support, 320Mb Recording Throughput, 16 Alarm Inputs & 4 Outputs, Rs485, Esata And Rs232 To Be Supported With Maximum 16 Users, Op. Temp -10 To 50 Deg. C, Ndaa Compliant, Ul/Ce/Fcc Certified, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Cp-Plus/Panasonic/Pi-Spw 201Dl/Bosch/ Octavision/Hikvision. , Supply And Installation Of Wallmounting Network Rack Supplyand Fixing Of 6 U Wallmounting Network Rack With Power Spike Including All Accessories Etc., Complete. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make:Hcl / Vall , Supply And Installation Of 8Port Poe Switch Supply & Fixing Of Small Business 8 Port Gigabit Poe Managed Switch, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. Make:Netgear/Dlink , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Lan Cable Cat -6 Utp Cable And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : D Link / Amp / Molex / Legrand / Krone, , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Hard Disk 8 Tb And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : Segate/ Sv-35/Toshiba. , Supply And Installation Of Air Conditioner A/C 2.0 Tonne A/C With Low Power Drive Module.Supply And Transportation Of Inverter Model Cool Type Split Ac Unitwith High Wall Mounted Single Split 100% Copper Indoor And Outdoor Condencing Unit Hermetically Sealed Compressor Suitable For Operation On 230V, 50Hz, 1Phase Ac Supply Capable Of Performing Heat Cool Dehumidifying Air Circulating And Filtering With Cooling And Condensing Units With 3.0 Mts Of Copper Piping, Insulation Kit And 4 Mts Of 4 Core Copper Flexible Chord (Voltage Range 160- 264 Volts) And Cordless Remote Control With Warranty Of Compressor For 5 Years And Comprehensive Maintenance For 2 Years2.0 / 1.8 Tr 5 Star Capable Of Delivering 21600 Btu/Hr And Above With Operating On Refrigerant R-32 / R-410 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Daikin / Toshibha / Carrier / Blue Star / Hitachi Or Equivalent , Supply And Installation Of Computers: Core-I7 10Th Gen Processor, 8Gb Ram, 1Tb Hdd, Windows 10 Pro. Specification: General :Wired Usb Keyboard & Optical Scroll Mouse 1 X Ps/2 Combo Port 2 X Usb 3.2 Gen 1 Ports 6 X Usb2.0 Ports 1 X Rj-45 Port 1 X Hdmi Port 1 X Vga Port 1 X Audio Port (Line Out/Line In/Mic In) 1 X Pci Express X16 Gen 3.0 Slot 1 X Pci Express X1 Gen 2.0 Slot 1 X Audio Port (Line Out/Line In/Mic In) 450W 19V/0.84A 80Mm X 310Mm X 395Mm 510Mm X 360Mm X 182Mm 12.5 Kg (Total Pc) Ce, Rohs Table Top 3 Years Warranty Cpu, Monitor, Keyboard & Mouse, User Manual, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Ups 10 Kva System (8 Kwatt ) Specification:Input Voltage 80 / 400 / 415 Vac; 3 Phase, Ninput Voltage Range ± 15%Input Frequency 50 / 60 Hzinput Frequency Range ± 10%Input Power Factor > 0,85Output Power Factor 0,8Output Voltage 380 / 400 / 415 Vac; 3 Phase, Noutput Frequency 50 Hz / 60 Hz (Selectable)Battery Type No Maintenance Batterybattery Unit 30Charge Voltage 405 Vdcbattery Charge Time 8 Hours To 90% Capacity After Deep Dischargebattery Test Automatic And Manuel Battery Test Systemover Load Capacity 100% ~ 125% Load 10 Minutes; 125% ~ 150% Load 1 Minute; > 150% Load On The Bypassdimension Wxhxd (Mm) 490 X 1200 X 680Weight ~ 240 Kg., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Generator (20Kva Dg Set) Specification: Power: 20 Kva (16Kw) Fuel Consumption (At 100% Load): 5.09 Ltrs/Hr Fuel Tank Capacity: 63 Ltrs Phase: 3 Phase Dry Weight (Kg): 720 Frequency: 50 Hz Engine: 2 Cylinder, In-Line 4 Stroke, Radiator Cooled Engine, Electrical Starter Motor With Soft Start Engagement Feature, Battery Charging Alternator. 1 X 12 V Dc Battery, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
12.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
13.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
14.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
15.
Public Administrative Department #10226673 Price Bid
Supply, Installation And Commissioning Of Machines, Tools And Equipment For New Age Courses In Itis Of Jharkhand Selection Of Agency For Supply, Installation And Commissioning Of Machines, Tools And Equipment For New Age Courses In Itis Of Jharkhand , A. General Tools , Pliers , Soldering Station , Multi Meter , Tweezers , Binoculars , Anemometer , Magnifier , B. List Of Equipment , Unassembled Drone , Electricity Lab , Smd Technology Kit With Wall Chart , Multiple Output Dc Regulated Power Supply , Dc Regulated Variable Programmable Dc Power Supply , Smart Smd Tweezer Handheld , 1 Mhz Mixed Signal Oscilloscope ( 4 Analog + 16 Digital Channel) , 25 Mhz Arbitrary Waveform Generator With Digital Display For Frequency And Amplitude , Handheld 3 3/4 Digit Multimeter , 3Ghz Spectrum Analyzer With Built-In Tracking Generator , Smd Soldering & De Soldering Station With Necessary Accessories , Or Drone Workbench , Analog-Digital Circuits Development Platform , Applied Mechanics Training Platform , Drone Battery Management Training Systems , Charge Controller Training System , Bldc (Brushless Dc) Motor Training System , Inverted Pendulum , Drone Sensor Trainer Kit , Antenna Training System , Advanced Microwave Integrated Circuit Lab , Gps Training Platform , Wireless Communication Modules , Fcb And Esc Training Platform , Drone Gimbal Set With Motor And Control , Npnt Compliant Micro Uav Built For Mapping And Surveillance. , Hd Payload , Thermal Camera Payload , Field Repair Kits , Drones And Spare Parts Kit , Balance Charger , Power Distribution Board , Laptop Latest Configuration , Thrust Measurement Meter , Indoor Netted Facility , Outdoor Controlled Netted Testing Facility , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations, Different Types Of Analog Electronic Components, Digital Ics. , 3D Printer , Drone Upto 18Km , A. Trainees Tool Kit (Foradditional Unit Trainees Tool Kit Sl. 1-12 Is Required Additionally) , Connecting Screwdriver , Neon Tester 500 V. , Screwdriver , Insulated Combination Pliers , Insulated Side Cutting Pliers , Long Nose Pliers , Soldering Iron , Electrician Knife , Tweezers , Digital Multimeter With 4000 Counts, Large Display With Auto/Manual And Can Measure Dcv- 1000V-Acv-750V, Dc & Ac A(Minimum) – 10A, Resistance (Minimum) 40M?, Capacitance Minimum 20?F, Capacitance And Frequency (Minimum)– 3 Mhz , Soldering Iron Changeable Bits , De- Soldering Pump Electrical Heated, Manual Operators , B. Shop Tools, Instruments – For 2 (1+1) Units No Additional Items Are Required , Steel Rule Graduated Both In Metric And English Unit , Precisionof Screw Drivers , Tweezers – Bend Tip , Steel Measuring Tape , Tools Makers Vice , Tools Maker Vice , Crimping Tool (Pliers) , Magneto Spanner , File Flat Bastard , File Flat Second Cut , File Flat Smooth , Plier - Flat Nose , Round Nose Pliers , Scriber Straight , Hammer Ball Pen , Allen Key(Hexagonalof 9) , Tubular Box Spanner , Magnifying Lenses , Continuity Tester , Hacksaw Frame Adjustable , Chisel - Cold - Flat , Scissors , Handsaw 450Mm , Hand Drill Machine Electric With Hammer Action , First Aid Kit , Bench Vice , List Of Equipments , Multiple Output Dc Regulated Power Supply , Dc Regulated Variable Programmable Dc Power Supply , Lcr Meter (Digital) Handheld , 70 Mhz Mixed Signal Oscilloscope ( 4 Analog + 16 Digital Channel ) , 25 Mhz Arbitrary Waveform Generator With Digital Display For Frequency And Amplitude , 6 1/2 Digit Digital Multimeter , 3Ghz Spectrum Analyzer With Built-In Tracking Generator , Or Electronics Workbench , Multi Function Test & Measuring Tool For Field Applications And Testing Compatible With Laptop , Electrical Safety Trainer , Analog Component Trainer With Following Seven Basic Modules • Diode Characteristics (Si,Zener,Led) • Rectifier Circuits • Diode As Clipper Circuit • Diode As Clamping Circuit • Zener As Voltage Regulator. • Transistor Type Npn & Pnp And Ce Characteristics • Transistor As A Switch , Digital Ic Trainer , It Workbench For Computer Hardware And Networking , Laptop Latest Configuration , Laser Jet Printer , Internet Broadband Connection , Electronic Circuit Simulation Software With Five User Licenses , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations. , Different Types Of Analog Electronic Components, Digital Ics, Power Electronic Components, General Purpose Pcbs, Bread Board, Mcb, Elcb , Smd Soldering & De Soldering Station With Necessary Accessories , Smd Technology Kit , Microcontroller Kits (8051) Along With Programming Software (Assembly Level Programming) With Six Important Different Application Modules 1. Input Interface Switch, Matrix Keypad, Ascii Keypad 2. Display Lcd, Seven Segment, Led Matrix 3. Adc & Dac 4. Pc Interface Module 5. Motor Dc, Stepper, Servo 6. Daq , Sensor Trainer Kit Containing Following Sensors A)Air Humidity And Temperature B)Rtd C)Atmospheric Pressure D)Air Quality E)Smoke Detector Sensors F) Limit Switch G)Photo Sensors H)Capacitive Displacement , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations. , Different Microcontroller/Processor Training And Development Platform For Avr, Pic, Arm And Ardui , Internet Of Things Explorer , Field Interface And Protocol Simulation Kit , List Of The Machineries , Solar Power Lab , Solar Pv Module Analyzer , Wireless Communication Modules For Interfacing With Microcontrollers A) Rfid Card Reader B) Finger Print C) Zigbee D) Gps E) Gsm F) Bluetooth G) Wifi , Sensors For Smart Environment Application , Sensors For Smart Parking , Sensors For Smart Water & Waste Water Management And Monitoring , Weather Monitoring System , Smart Solar Street Lighting Training Platform , Iot Based Smart Streetlight System , Smart Transportation Monitoring System , Sensors For Smart Building , Iot Data Acquisition Systems And Protocol Converters , Iot Edge Computing Device , Cloud Based Iot Scada , D. Shop Floor Furniture And Materials - For 2 (1+1) Units No Additional Items Are Required. , Instructor’S Table , Instructor’S Chair , Metal Rack , Lockers With 16 Drawers Standard Size , Steel Almirah , Interactive Smart Board With Projector , Fire Extinguisher , A. Trainees Tool Kit , Steel Rule , Hand Gloves , Safety Shoes , Helmet , B. Tools, Instruments And General Shop Outfit , “V” Block , “V” Block , Micrometer Outside , Vernier Caliper , Micrometer Inside , Metal L , Metal L , Angle Plate , Spirit Level , File Warding , File Knife Edge , File Cut Saw , File Feather Edge , File Triangular , File Round , File Square , File Square , File Triangular , File Flat , File Flat , File Flat , File Swiss Type , File Half Round , File Half Round , File Round , File Hand , Card File. , Oil Stone , Pliers Combination , Blow Lamp , Spanner , Spanner Adjustable , Box Spanner , Glass Magnifying , Clamp Toolmaker , Clamp “C” , Clamp “C” , Scraper Flat , Scraper Triangular , Scraper Half Round , Chisel , Chisel , Chisel , Motorized +Tenn Saw , Hand Hammer , Hacksaw , Mallets Wooden , V-Block, Files, Mallets, Screwdrivers, Chisels, Etc. , Hand Drilling Machine , Metal Saw , Straight Grinder Heavy Duty With Attachments , Professional Air Blower , Jig Saw Portable , Hammer Drill Wired , Hand Held Sander / Polisher , Digital Dial Torque Wrench , Lifting Tackle/Sling , Impact Wrench , Laser Light Pen , Surface Plate , Digital Screw Pitch Gauge , Laser Distance Measurement Instrument , Palm Scale , Allen Screwdriver Wrench Tool , Universal Quick Adjustable Multi-Function Wrench Spanner , Double Ended Wrench Hex Socket Spanner , C. General Machinery / Software Installations (Automobile Bom) , Car Lift -4 Ton , 2 Wheeler Bike Or Scooter Assembly Set , Transmission / Gearbox Demo Kit , Cooling System Components Arranged On A Stand With Electric Motor , Exhaust System , Mini Commercial Vehicle Chassis Structure , Rear Axel , Suspension System-Front And Rear On Stand , Steering Wheel And Tyre Systems Assembly On Stand , Disc 7 Drum Brake Systems On Stand (Working Model) , Engine And Transmission Systems On Stand (Working Model) , Hvac Demo Kit , Electronic Ignition System Of An Automobile 4 Wheeler , Demonstration Board Of Working Model Mpfi System With Motorized Control , Instruction Kit For Charging System , Instruction Kit For Starting System , Lighting And Wiring System Mock Layout , System Set Up And Integration With Design. , Electric Vehicle , Electric Vehicle Kit Chassis (In Sets) , Multimeter Digital , Ammeter Able To Read Upto 300 A , Continuity Tester , Tyre Pressure Gauge , Measuring Tape , Electrical Soldering Iron , A. Trainees Tool Kit , Steel Rule , Engineer’S Square , Bevel Straight Edge , Centre Punch , Dot Punch , File Flat Bastard , File Flat 2Nd Cut , File Flat Safe Edge , File Triangular Rough , Hammer , Scriber , Vernier Caliper , Micrometer (Outside) , Safety Goggles (Personal Protective Equipment) , Screw Driver Electrician , Screw Driver , Long Nose Plier , Combination Plier , Diagonal Cutter , Screw Driver Philips , Tweezers , Knife , Wire Stripper , Neon Tester , Scissors , Soldering Iron , Bread Board , B: Tools And Equipments: , Caliper Outside , V-Block , Divider – 150 Mm , Screw Driver , Circlip Plier (Inside And Outside) Each , Centre Gauge , Oil Can , Oil Gun And Grease Gun Each , File Flat Smooth , File Flat Smooth , File Half Round Bastard , File Half Round Smooth , File Triangular Smooth , File Round Bastard , File Square Smooth , Knife Edge File , Needle File Assorted (12 Nos.) , File Card (Spattle) , Scraper Flat , Hammer Ball Peen , Hammer Cross Peen , Chisel Cold Flat , Chisel Cross Cut , Chisel Half Round , Chisel Diamond Point , Scribing Block , Cast Iron Surface Plate , Granite Surface Plate , Tap Extractor , Screw Extractor , Hand Taps And Dies , Bench Vice , Machine Reamer , Machine Tap Set , Twist Drill , Twist Drill , Taper Shank Drills , D.E Spanners , Letter Punch , Number Punch , Parallel Block Standard Sets , Allen Key Metric , Centre Drills , Parallel Hand Reamer , Star Dresser , Diamond Dresser With Holder , Surface Gauge , Angle Plate-Adjustable , Micrometer –Inside – Outside , Vernier Caliper With 0.02Mm Least Count , Digital Vernier Caliper , Digital Micrometer( Inside, Outside And Depth ) , Height Gauge , Vernier Bevel Protractor , Sine Bar And Sine Centre Each , Sprit Level , Slip Gauge Set ( Std ) , Magnetic Stand , Dial Test Indicator , Dial Test Indicator , Bore Gauge , Straight Edge-Single Beveled , Tool Maker’S Clamp , C – Clamp- , Bearing Puller , Ammeter , Ammeter , Voltmeter , Pf Meter , Phase Sequence Meter , Digital Multi Meter , Energy Meter, Single / Three Phase , Clamp On Meter , Ammeter Portable Type , Test Lamp , Tong-Tester , Line Tester , Batter Tester , Electrician Tool Kit , Rechargeable Battery , Pressure Transducers Panel Board To Demonstrate Pressure Gauge, Load Cell, Bourdon Tube, Capacitive Transducers. , Flow Transducers Panel Board To Demonstrate Flow Nozzle, Vane Anemometer, Rota Meter. , Temperature Transducers Panel Board To Demonstrate Bimetallic Strip, Rtd, Thermocouple, Thermistor. , Level Transducers Panel Board To Demonstrate Capacitive And Float Switch. , Insulated Screw Diver , Insulated Combination Cutting Plier , Small Screw Driver , C. Tools & Equipment Of Electrical & Sensors , I) Electrical , Digital Multimeter , Variable Resistance Box, Resistors , 9V Dc Battery With Cap , Dual Power Supply , Solder Iron, Solder Lead, Pcb Board (Groove Board), Solder Wick , Inductor , Relay, Led , Function Generator , Bread Board , Synchronous Motor, Capacitor For Synchronous Motor , Power Chord, Connecting Probes, Single Strand & Multi Strand Wires , Ii) Senors , Power Supply , Sensor Kit , D. Mechatronics Lab Outfit , Discrete Component Tester Trainer Kit , Analog Circuit Trainer Kit , Soldering And De Soldering Station , Power Electronic Trainer , Ac Squirrel Cage Induction Motor , Dc Motor Trainer Board. , Auto Transformer , C.R.O , 50 M Hz , Digital And Analog Ic Tester , Digital Tachometer , Signal Generator , Dc Power Supply Unit , Digital Earth Tester , Firefighting Equipment , Linear Ic Trainer Kit , Ac / Dc Motor Speed Control Trainer Kit , Optical Transducer Trainer Kit. , Simple Servomotor Trainer Kit. , Simple Stepper Motor Trainer Kit , Linear Scale Setup For Positional Accuracy Check , A/D And D/A Trainer Kit , Ups , Stabilizer Trainer Kit , Ac Drive , Dc Drive , Digital Circuits Trainer Kit. , 8051 Microcontroller Trainer Board With Led, Switches, Buzzer, Dc Motor And Stepper Motor Interfacing Circuits. , Plc With Io Simulation Panel And Programming Software With Plc Application Module , Ethernet To Profibus Converter , Hmi , Personal Computers , Operating System (Windows Latest Version) , Portable Hard Disk.(1 Tb) , Ms-Office , Rj45,Bnc,D-Shell, Edge Connector Crimping Tool , Megger , Encoder Trainer Kit , Panel Wiring Work Bench , Protection Devices Trainer Board. , Limit Switch, Pressure Switch, Micro Switch, Float Switch, Foot Switch , Application Trainer Kit Of Proximity Sensor, Float Switch, And Reed Switch , Lvdt Trainer Kit. , Actuators Application Trainer(Servo, Stepper Motor, And Solenoid) , Simple Servomotor Trainer Kit. , Simple Stepper Motor Trainer Kit. , Piezoelectric Transducer/Actuator Trainer Kit. , Pneumatic Control Trainer Kit With Required Pneumatic Components. , Hydraulic Control Trainer Kit With Required Hydraulic Components. , Electro-Pneumatic Control Trainer Kit Using Plc With Required Components. , Electro-Hydraulic Control Trainer Kit Using Plc With Required Components. , Linear Scale Setup For Positional Accuracy Check , Plc Based Conveyor System With Pick And Place And Sorting Of Objects (Pneumatic And Hydraulic) , Cut Section Models Of Pneumatic And Hydraulic Motors ,Pumps , Electrical Simulator Software , Electronic Simulator Software , Hydraulics And Pneumatics Simulator Software , E. General Shop Outfit , Sensitive Drilling Machine , Pillar/Column Type Drilling Machine , Power Hacksaw Machine , Double Ended Pedestal Grinder , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: , Shearing Machine (Lever Type) Hand Operated Complete , Universal Milling Machine , Horizontal And Vertical Milling Machine , Hydraulic Surface Grinding Machine , Universal Cylindrical Grinding Machine , Cnc Turn Centre , Cnc Vertical Machining Centre , Drafting /Autocad Software , Mechanical Parametric Design /Creo (Proe) Software , Simulation Software
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
16.
Housing Urban and Rular Development #10191469 AOC
Furnishing Work Of Classrooms, Library And Laboratory, Equipments And Miscellaneous Work For The New University Campus Of Binod Bihari Mahato Koyalanchal University, Dhanbad- 1 Supplying Metal Exhaust Fan 300 mm Sweep-Supplying, erecting and testing of approved make 300 mm sweep Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including frame bolt/ Anchor hole fastners etc, complete finished of a as required. 2 Wall Demolition- Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 3 Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 4 Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5 Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 6 Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 7 Door Frame- Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile C - Fixing with adjustable lugs with split end tail to each jamb 8 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. 9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. 10 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.-Granite stone slab colour black, Cherry/Ruby red-Area of slab over 0.50 sqm 14 Sink- Supplying fitting and fixing white glazed fires clay sink of approved make with overflow arrangements supported on C.I. Or R.S. Painted bracket 40mm. Dia C.P. Brass waste with C.P. Brass chain and rubber plug 40mm dia P.V.C. Waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Size-600 mm x 450 mm x 250 mm ) 15 FULL HEIGHT WOODEN PARTITION WITH PARTLY GLAZING- Providing and fixing partitions made of 50 mm x 50 mm pine wood / 2nd class teak wood @ 600 mm c/c both ways with the help of Fasteners/Screws etc. to achieve desired strength. Providing & fixing Comm. grade 12 mm thick commercial Pty board on the frame on both the faces i/c exposed side edges of Frame & 1.0mm thk Laminate on both outer faces and exposed side edges of ply as per the directions. Partition shall also be provided with 8 mm thick clear float glass of approved size with Polished Edges of approved brands in Wooden Partition Openings as required, fixed from all four sides from both ways inside partition openings with 10mm.tk. T.W. beadings/12 mm thick MDF Board Lipping/D-Buttons of design as per approval and direction at site. Etching / Etching Film (50 Microns) is to be provided as per approved pattern on 8 mm thick clear float glass. All wooden exposed surfaces shall be melamine polished in approved shade and texture finished as per the directions and satisfaction of Engineer In charge, compelete.This work will 16 Frosted glass sheet of nominal thickness 4 mm- Providing and pasting frosted film on glass work including all materials tools, plants and labour complete as per the directions of the Engineer-in-charge. 17 Supply & laying of PVC insulated and sheathed 1.1 kv grade twin twisted 1.5 sqmm cu flexible wire for speaker. 18 Providing & installation 1.5 Tr. 5 Star split A.C (Inverter Type) I91391-part-1 19 Copper refregerant pipe-Providing & installation Copper Tube of size 5/8 for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation 20 Providing & installation 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280V 21 Providing & installation Drain Pipe for AC 22 Non Schedule 23 * PROVIDING AND SUPPLYING MODERN DESIGN RECEPTION DESK IN ENGINEERED WOOD MAKE THE PRODUCTS UTILE AND A DELIGHT.TIMELESS DESIGN THAT ELEVATES YOUR OFFICE SPACE STRUCTURE OF SPACIOUS RECEPTION DESK,TABLETOP OFFERS YOU A GENEROUS LOOK FOR WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 1800 MM(L)X 600 MM(D)X 750 MM(H) WHICH GIVE MORE SURFACE AREA FOR WORK ,TABLE TOP MADE OF25MM THICK ALSO TABLE TOP BASED ON SIDE PANELS MADE 18MM THICK PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST. * COMBINATION CONSTRUCTION OF RECEPTION DESK ABOVE TABLE TOP 18 MM THICK COUNTER TOP TO TABLE TOP HEIGHT IS @ 300MM ,OVERALL RECEPTION DESK HEIGHT IS @ 1050MM WITH COUNTER TOP,TABLE TOP MADE 25 MM THICK PRELAM PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK PVC EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXED WITH HOT MELT GLUE.ALONG WITH 18MM THK ADDITIONAL MODESTY PANEL SIZE IS 1350 MM (L) X 700 MM (H) MADE BY EXCLUSIVE FROSTY WHITE COLOUR WITH EPIC DESIGN & LOOK.1 MOBILEPEDESTAL (2 DRAWERS + 1 FILING CABINET )SIZE IS 450 MM(L)X 450 MM(D)X 725 MM(H) IN PROVIDED WITH CENTRAL LOCKS FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING & PEDESTALS MOVE ON NYLON CASTORS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST 24 PROVIDING AND SUPPLYING * MEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 580MM(L)X 670MM(D)X1110MM(H) ,*THE CHAIR MADE OF FULL UPHOLSTERY IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : AMREST IS HAVING TWO ADJUSTMENT HEIGHTS (UP & DOWN) .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM. SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 480MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1110MM & MINIMUM HEIGHT IS1010MM* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650MM NYLON BASE WITH SMOOTH CASTORS . 25 PROVIDING AND SUPPLYING 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION,THREE SEATERTYPE WAITING AREA CHAIR - MATERIAL : STAINLESS STEEL SIZE 1820MM(L)X 690MM(D)X 790MM(H) COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 26 Supplying of Portrait/Landscape Not applicable Fabric Pin Up Notice Boards(Fabric Pin Up Notice Boards 3 X 6 FT GREEN),Specification-Width of Board in mm:900 mm,Colour(Front/ Display layer):Green,Height of Board in mm:1800mm,Rear panel material of Board:Laminated sheet,Overall pinability depth ofBoard in mm:9 millimeter,Core material thickness inmm:9 millimeter 27 PROVIDING AND SUPPLYING COLLEGE DESK TOMKINS MATERIAL : PRELAMINATED PARTICLE BOARD WITH M.S BASE UNIT SIZE : 590 MM(L) X 1090 MM(D) X 830 MM(H) PER SEAT SIZE- 590 MM X 375 MM X 450 MM/ONE SEATER DESK SIZE :1090 MM(L) X830 MM(H) COLOUR : AVAILABLE ON REQUEST/FINISH : EPOXY POLYESTER ,* PROVIDING & SUPPLYING TWO SEATER COLLEGE DESK TOMKINS COMBINATION OF THREE ROWS FIRST , MIDDLE AND LAST SCRATCHPROOF EASY WIPE TOP / DURABLE ,STRONG & SAFE,UNDERSTRACTURE MADE OF MAIN FRAME MDE OF CRCA POWDER COATED IS GRAD:304 M.S BLACK POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) EPOXY POLYESTER COATING.* TABLE TOP & MODESTY PANNEL MADE IN 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS.CHAIR WITH GAS LIFT ,A). BACK FRAME: 1.2MM COLD ROLLED STEEL/B). BACK BOARD: 10MM PLYWOOD, NO CUSHION C). SEAT BOARD: 15MM PLYWOOD, NO CUSHION/D). TIP-UP SYSTEM: SPRING MECHANISM E). 2. LEG: COLD-ROLLED STEEL, FIXING ON THE FLOOR BY SCREWS, 80 X 35 X 1.5MM THICK OVAL TUBE, BLACK POWDER SPRAYING.* THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST 28 Supplying of Material & Subtype Engineered Wood Table Top Material Engineered Wood Finish Matte Colour & Colour Family Brown - Classic Walnut Dimension (W)550mm X (D)550mm X (H)1200mm Size Compact Assembly Type Knock Down (Obelisk), 29 Suppling of Writing Board ( 4x10 Non-Magnetic) of material Top Surface materials (Used for white boardsurface)-Porcelain,Top surface material thickness -0.7 mm to 0.8 mm,Frame material -Anodized extruded aluminum alloy hollow section conforming to IS 733 (With latest amendment),Frame wall thickness-1.2 mm,Frame section front -20 mm,Frame section side -16 mm,Core material-MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness -9 mm as per Department incharge 30 Supplying of 14 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 8850 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 8850 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST, * CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST, 31 Supplying of * HIGH BACK 360° DEGRE REVOLVING CHAIR SKU : MARVEL/HB/ECO ,* ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1380MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM . * ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) , SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1380MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 32 Supplying ofMEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1125MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM .* ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) ,SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1125MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 33 Supplying of Tte Mild Steel Pipe of diameter 19 mm and wall thickness 16gauge. Classroom Chairs, tte,Thickness-2mm to 45mm,Material-Mild Steel Weight-Depends upon the size,Outside Diameter-0.80 Inch to 36 Inch 34 Supplying of 1-Bay Sprocket Chain Drive Mechanism MobileStorage Compactors,Material-Mild Steel Product Type-1 Bay,Height -7 ft,Storage Capacity-50-80 kg Usage/Application office, Home, Hospital, Store Room, Warehouse 35 Supplying of -- Movable File StorageSystem (Compactor) 1-Bay Mechnized Drive Type(COMPACTOR 2 ( 04 BODY)) 36 Supplying of Methodex MS1-6MCMETHODEX(Methodex MS1-6MC),Accutec Mobile Storage System,Material SS,Usage/Application-Warehouse Height-8-10 Feet,No of Layers-5 37 Supplying of : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 38 Supplying of : PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK . * PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 39 Supplying of* HIGH BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 590MM(L)X 505MM(D)X1280MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING . * USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * MECHANISM : KNEE TILT MECHANISM . * ONLY SEAT SIZE IS 505MM(L)X 505MM(D)X610MM(H) & THE BACK SIZE IS 590MM(L)X 710MM(H) SEAT MAXIMUM HEIGHT IS 610MM & MINIMUM HEIGHT IS 510MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1280MM & MINIMUM HEIGHT IS1180MM * GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650 MM CHROME BASE WITH SMOOTH CASTORS . 40 Supplying of* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 570MM(L)X 500MM(D)X940MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE . DETAILS : * ARMS : PADDED ARMREST. * USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED. * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * ONLY SEAT SIZE IS 570MM(L)X 500MM(D)X475MM(H) SEAT HEIGHT IS @ 940MM & BACK HEIGHT IS @ 475MM . * FIXED CANTILEVER CHAIR . * BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 41 * SUPPLYING AND PLACING FIVE SEATER (3+1+1) EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 3 SEATER- 1905MM(L) X890MM(D)X 870MM(H)SOFA SIZE IS 1 SEATER -(W)960mm X (D)890mm X (H)870mm ,WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME. * COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 28 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 50MM THIK,40MM THICK BACK FOAM HAVING 20 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 20 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BLACK-EERIE BLACK-COFFEE BROWN,BROWN-BURNT UMBER COLOUR, IT COMPLEMENTS THE MODISH LEGS ARE MADE BY ROUND SHAPE IN PVC MATERIAL. 42 Supplying of Material & Subtype Solid Wood - Beech Wood Table Top Material Clear Glass,Frame Material Solid Wood Leg Material Solid Wood,Finish Matte Colour & Colour Family Brown - Walnut,Dimension (W)1130mm X (D)630mm X (H)410mm,Number Of Recliners 1 Number Of Reclining Positions 3,Size Standard (HOPPER/CT), 43 Supplying of6 SEATER Rectangular MEETING TABLE DURIAN MODEL SMART/CON/6FT MADE OF PRELAMINATED PARTICLE BOARD WITHSLANTLEGS50X50 MM MS UNDERSTRUCTURE IN POWDER COATING 2TOP MADE OF25MMTHICK PRELAMINATED PARTICLE BOARD IN FROSTY WHITE COLOR WITH MAIN TABLE SIZE1800MM(L)X 1050MM(D)X 750MM(H) (SMART/CON/6FT/A), 44 SUPPLYING & PROVIDING CAFETERIA CHAIR SIZE IS 381MM(L)X 419MM(D)X839MM(H) A COMBINATION OF SYNTHETIC FIBER WITH STAINLESS STEEL MAKE THE PRODUCTS UTILE AND A DELIGHT, THE COMPLETE STRUCTURE SHALL BE MADE UP OF 20% GLASS FILLED BLOW MOLDED HIGH-DENSITY POLYETHYLENE ANDIS,THE FRAME STRUCTURE SHALL BE SUPPORTED BY ( 2 STRAIGHT + 2 SLANT ) FOUR LEGS.THE TUBULAR WELDED FRAME IS MADE FROM DIA2.22 +/- 0.03CMX 0.12+/- 0.0128 CM AND 3.5+/- 0.03 CM X 0.12+/- 0.0128 AM STAINLESS STEEL 202 GRADE TUBE & THE TUBE ARE BUFF POLISHED TO GIVE SHINY FINISH.SEAT AND IN BACK GIVEN HANDLE TO HOLDARE MADE OF INJECTION MOULDED HIGH IMPACT STRENGTH POLYPROPYLENE POLYMER COMPOUND WITH INDOOR GRADE UV RESISTANCE AND PRESSED FITTED WITH LEGS.THE CHAIR IS EASY TO STORE WHEN NOT IN USE, SINCE YOU CAN STACK UP TO 6 CHAIRS ON TOP OF EACH OTHER. (COCO/SUR). 45 SUPPLING OF METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1830MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET.HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, FITTED WITH MS BODY LOCK & HANDLE. WITH 2 NUMBERS OF GLASS DOOR SHUTTERS , THE GLASS USED SHALL BE 4MM THICK CLEAR. UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 30 KG MAXIMUM.EACHRACKSHALLBEPROVIDEDWITHSTIFFENERATBOTTOMFOR STRENGTH.THE ENTIREBODYPANELAND SHELF SHALLBEMADEOF HIGHYIELD STRENGTH,THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY 46 SUPPLING OF DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 750MM(D)X 750MM(H) 36MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITHWENGE FINISH, USING HOT MELT GLUE TO FIXING 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 25MM THICK.*PROVISION OF SIDE RUNNER OF SIZE IS 750MM(L)X 450MM(D)X 760MM(H) ,( CONSTRUCTION IS FROM RIGHT SIDE OF SIDE UNIT TOP BASED ON FIXED PEDESTAL WITH SS STUD OF GRADE 304, ON TABLE TOP PVC GROMENT HOLEFOR WIRE MANAGEMENT .*FIXED PEDESTAL OF SIZE450MM(L)X 450MM(D)X 650MM(H) PER DRAWER HEIGHT IS @ 136MM, FILLING DRAWER HEIGHT IS @ 300MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 47 SUPPLING OF* CANTILEVER CHAIR SKU : 70011/CN/A, * ALL OVER SIZE IS : 590MM(L)X 490MM(D)X980MM(H) , *THE CHAIR MADE OF FULL FABRIC INBLACK COLOUR . IT WILL COMES INFINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS : FIXED ARMS P.P. CONNECTED WITH SEAT AND BACK .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32(±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* BASE : M.S POWDER COATED TUBLAR FRAME OF CATILEVER TYPE . THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. 48 SUPPLING OF OFFICE DESKDESK STRUCTURE OF L SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL 18MADE OF MM THICK . *PROVISION OF SIDE UNIT OF SIZE IS 900MM(L)X 450MM(D)X 750MM(H) ,(COMBINATION CONSTRUCTION WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP, LEFT SIDE TABLE TOP BASED ON A 18MM THICK SIDE PANNEL ENGINEERED WOOD & FROM RIGHT SIDE UNIT HAVE 2 SLIDING DOOR + 1 FIXED SHELVE . *SIDE UNIT SIZE900MM(L)X 450MM(D)X 750MM(H), IN PROVIDED WITH LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF SIDE UNIT IS 18MM THICK ALONG WITH FECIA OF SLIDDING SHUTTERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST . 49 SUPPLING OF * FIX CANTILEVER ,* ALL OVER SIZE IS : 595MM(L)X 510MM(D)X875MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 500MM(L)X 510MM(D)X455 MM(H) & THE BACK SIZE IS 440MM(L)X 595MM(H) , BACK HEIGHT IS @ 440MM .* BASE : 4 LEGS METAL POWDER COATED* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 50 * PROVIDING AND SUPPLYING PENTA WORKSTATIONLSHAPE SINGLE SEATER UNIT NON SHARING IN COMPLETELY KNOCK DOWN CONDITIONS WITH AN OVERALL SIZE 1500MM(L)X 600MM(D)X 1200MM(H) THAT IS TO BE ASSEMBLED AT SITE. THE WORKTOPSHALLHAVETHESIZE1490MM-1490MM (L) x 592(D) MADEUPOF25MMTHICKPRE- LAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST . OF IS LEVEL WITH APPROVED LAMINATE AND FINISH AS PER APPROVED SHADE. * THE PROFILE OF THE TOP SHALL BE IN RECTANGLE SHAPE AND THE EDGES SHALL BE SEALEDWITH 2MM THICK THIN STRIP OF IMPERMEABLEPVCTHAT IS CUT TO FIT THE SIZE OF BOARD PANEL AND DULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THE TOP TRIM, TOP BAR, MID BAR, VERTICAL BAR, RACEWAY, SKIRTING SHALL BE MADE UP OF ALUMINIUM EXTRUSIONS (PRE-TREATED)AND DULY POWDER COATED WITH POLYESTER POWDER COATING 40P-60PTHICK . THE TRIMS SHALL HAVE THE SIZE 67MM X 19MM WITH 1.5MMTHICKCOVERED WITH DIE CAST END CAPS ON JOINTS 2 WAYS,3 WAYS& 4 WAYS(L-COVERFORCORNER,T-COVERFORMIDDLESECTIONWHEREVER REQUIRED).THEALUMINIUMRACEWAYSHALLBESITUATEDBELOWTHEWORKTOPWITHAN OVERALLSIZE149MM(H)X60MM(D)WITH1.4MMCOVERTHICKNESSAND2MMBACK THICKNESS AS PER REQUIREMENT OF INLAYING THE ELECTRICAL MANAGEMENT AND CARRYING THE WIRE HORIZONTALLY. *THE EXPOSED VERTICAL AND HORIZONTALFACES OF THE FRAMES SHALL BE SNAPFITTEDWITHTRIMS.THERESHALLBESOFT-BOARD(WITHFABRIC)ANDMARKERBOARD PROVIDED AT FRONT OF THE USER. LAMINATED TOP TILE AND BOTTOM TILE SHALL BE SITUATED AT BOTH SIDES OF THE USER AND BELOW THE WORK TOP RESPECTIVELY. THE PARTITION SHALL HAVE CONCEALED WIRE MANAGEMENT CAPABILITIES AND SHOULD BE ENGAGED FOR RESPONSIVE AND SAFE OPERATIONSOF POWER,TELECOMMUNICATIONSANDDATA(LAN)AND HASSEPARATE COMPONENTS FOR ELECTRICAL, DATA AND TELEPHONE CABLES HAVING ADEQUATE CAPABILITY OF BOTH THE VERTICAL AND HORIZONTAL WIRE MOVEMENTS.SLOTS/CUT-OUTS SHOULD BE GIVEN ON RACEWAYSTOFIXALLELECTRICALANDDATAPOINTS.SINGLESIDEDPVCWIRE MANAGER SHOULDBE ENCLOSEDATTABLETOP.ADJUSTABLE LEVELLERSHOE SHALL BE PROVIDED AT BOTTOM OF THE PARTITION TO AVOID SCRATCHESON THE FLOOR.PARTICLE BOARD OF GRADE II OFISLEVEL. * THREE LAYER PRELAMINATED PARTICLES BOARD (WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST .* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 51 PROVIDING & SUPPLYINGFIXING OF TWO SEATER SCHOOL DESK WITH SHELF/STORAGE UNDER DESK WHICH ONE MADE BY CAST IRON,DESK TOP MADE BY 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST,TWO SEATER CLASSROOM DESK CUM BENCH, TOTAL SIZE OF BENCH : 1050MM(L)X 950MM(D)X 760MM(H) DESK SIZE : 1050MM (W) X 400MM (D) X 760MM (H) BENCH SIZE : 1050MM (W) X 310MM (D) X 390 / 760MM (H) BACK SIZE : 1050MM (W) X 150 MM (H),TABLE TOP SHALL BE POLYPROPYLENE CO POLYMER (PPCP).BANDING UNDER STRUCTURE-BLACK 9005 ERW PIPE (AS PER IS:7138) : 25X25X1.2MM SQUARE MS PIPE, OF THICKNESS 1.2MM IN BLACK EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) AT BASE WITH PLASTIC CAPS MADE OF PP COPOLYMER (3530 GRADE) ARE ALSO PROVIDED ON THE REAR FRAMES ADDING MORE AESTHETIC VALUE TO THE PRODUCT. * ADDITIONAL HORIZONTAL SUPPORTS OF M.S. C SECTIONS OF 1.5MM THICK ARE PROVIDED BELOW THE DESK & SEAT.SHELF: 0.8MM THICK POWDER COATED M.S. SHEET BELOW THE DESK & HOOKS ON EITHER SIDE OF DESK IN M.S. ROD OF DIA 6MM.TOP,SEAT AND BACK PANEL: 18MM THICK PRE LAMINATED BOARD WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST.* 52 Suplying of Laboratory Steel Furniture Sidebench with rack and table top of specification,Size of side benches/Island benches (LxWxH):1800 mm X 1800 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 53 Supplying of Laboratory Steel Furniture Island bench with table top Size of side benches/Island benches (LxWxH):900 mm X 1500 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 54 Supplying ofPowder coated Round Classroom Stools Load of 50 Kg of stool of specification:Height Adjustment: Without Hydraulic,Frame and support made of CHROME PLATED MS TUBES,Chair Type:Non Revolving,Type of seating:Only seat,Pedestal base :Aluminium Die Cast 55 Suppling of Over Head Storage delite hi-tech of specification Material of Construction:ISI Marked, three layer Prelaminated particle Board conforming to Grade II Type III of IS 12823/2013 laminated with 0.6-0.8 mm thick lamination conforming to IS 2046/1995 and balancing lamination of 0.5 mm thick on the back side,Number of Shelves (Nos):2 Number of Doors (Nos) -2 ,Height in mm (±10 mm)-750,Depth in mm (±5 mm)-450 56 Suppling ofStainless Steel Name Plates, Monograms, Labels, As per BHEL ,Specifications :Stainless Steel Name Plates, Monograms, Labels, 57 Suppling of Aquaguard RO & UV both SS304 Drinking Water Coolers With Built In Water Purifiction System AquaguardR 58 Suppling ofStainless Steel External Branding Signage Boards, Size 22X6 Feet,Signage Printing-Single size vinyl print ,Material -Stainless steel ,Coating: Gloss or matte,Fabrication Specs-framing with one coat of red oxide & 2 coats of oil paint to avoid rusting 59 PROVIDING & SUPPLYING DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2100MM(L)X 900MM(D)X 750MM(H) 50MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH CLASSIC WENGE BROWN FINISH 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 50MM THICK* PROVISION OF SIDE RUNNER OF SIZE IS 1200MM(L)X 400MM(D)X 760MM(H) ,(CCOMBINATION ONSTRUCTION BELOW TABLE TOP 1 KEY BOARD TRAY IN PVC WITH TELESCOPIC CHANNEL ON RIGHT SIDE IS MOVABLESIDE RUNNERHAVING 1 OPENABLE DOOR WITH 1 FIXED SHELVE, 1 OPEN BOX WITH 1 FIXED SHELVE UPPER SHELVE HEIGHT IS @ 320MM BELOW SHELVE HEIGHT IS @324@ + 3 DRAWERS (2 EQUAL DRAWERS + 1 FILLING DRAWER)PER DRAWER HEIGHT IS @ 184MM, FILLING DRAWER HEIGHT IS @ 303MM HAVE CENTRAL LOCKAND HANDLES WITH CASTORS .* MOBILE PEDESTAL OF SIZE400MM(L)X 530MM(D)X 671MM(H) ,PER DRAWER HEIGHT IS @ 186MM, FILLING DRAWER HEIGHT IS @ 195MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 60 PROVIDING & SUPPLYING* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 610MM(L)X 505MM(D)X990MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORTbackrest support* ONLY SEAT SIZE IS 610MM(L)X 505MM(D)X485MM(H) & THE BACK SIZE IS 610MM(L)X 540MM(H) ,* BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 61 PROVIDING & SUPPLYING OFFICE DESK STRUCTURE OF RECTANGULAR SHAPE .PRIMARY WORK SURFACE OVER ALL SIZE IS 1200MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF 25MM THICK PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL MADE OF 18MM THICK, WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP.*CONSTRUCTION RIGHT SIDE OF TABLE TOP IS BASED ON A FIXED PEDESTAL3 DRAWERS & FROM LEFT SIDE OF TABLE TOP IS BASED ON 18MM THK ENGINEERED WOOD PVC EDGE BANDING PEDESTAL BACK,TOP,BOTTOM & DRAWERS ARE MADE OF 18MM THICK WITH 1 CPU TROLLY MADE IN BLACK METAL POWDER COATED.*FIXED PEDESTAL:L:410MM(L)X 580MM(D)X 750MM(H) ,IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823. 62 Suppling of Material & Subtype Solid Wood - Beech Wood Table Top Material Solid Wood,Leg Material Solid Wood Finish Glossy Colour & Colour Family Brown - Walnut Dimension (W)680mm X (D)530mm X (H)450mm Table Top Thickness 8mm,Size Compact, 63 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 838MM(L)X 305MM(D)X 1676MM(H) STEEL BOOKCASE HAVING 4 DOORS AND K. TYPE OF LOCK: THREE WAYBOLTING DEVICE CONTROLLED BY LOCK, THICKNESS OF MS SHEET USED FOR SHUTTER: 0.7 MM, THICKNESS OF MS SHEET USED FOR SHELF: 0.7 MM, THICKNESS OF MS SHEET USED FOR TOP,BOTTOM, BACK AND SIDES: 0.7 MM, MATERIAL OF HANDLE: CAST BRASS, THICKNESS OF TRANSPARENT GLASS IN SHUTTERS: 4.0 MM, THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 60-80 MICRONIN COLOR GREY-LIGHT GREY. 64 Suppling of 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION DURIAN,THREE SEATERTYPE WAITING AREA CHAIR -NIXON/SS/3 MATERIAL : STAINLESS STEEL,SIZE 1820MM(L)X 690MM(D)X 790MM(H)COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 65 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE) 6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY. 66 PROVIDING & SUPPLYING * FIX CANTILEVER CHAIR PROVIDING & SUPPLYING* ALL OVER SIZE IS : 590MM(L)X 490MM(D)X940MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED.* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 35 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 590MM(L)X 490MM(D)X450MM(H) SEAT HEIGHT IS @ 450MM .* BASE : 2 CHROME LEGS + BACK SIDE BOTTOM CHROME IN METAL . 67 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM). 68 SUPPLYING AND PLACING30 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated ParticleBoards Of Grade-II Type-II Of IS:12823/Latest (for 14 seater rate devided by 30X24} 69 SUPPLYING AND PLACING PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OFSUPPLYING AND PLACING PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK .* PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 70 SUPPLYING AND PLACING* HIGH BACK 360° DEGRE REVOLVINGCHAIR * ALL OVER SIZE IS : 673MM(L)X 508MM(D)X1270MM(H) , *THE CHAIR MADE OF FULL NATURAL LEATHER IN BROWN COLOUR . IT WILL COMES IN MATTE FINSIH EXTRA PADDED DESIGNED FOR MORE CONFIRMT AT WORKPLACE IN CONTEMPORARY STYLE . DETAILS :* ARMS : WOODEN ARMS WITH LETHER PADDING ARM REST ARE FITTED TO THE SEAT & BACK.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT . * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK .BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : MULTI-LOCKING KNEE TILT MECHANISM .SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 500MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1270MM & MINIMUM HEIGHT IS 1219MM* GAS LIFT 80MM TELESCOPIC HAUDRAULIC * BASE : THE PRONG (BASE) IS MADE OF SOILD WOOD WITH POLISHEDAND FITTED WITH 5 NUMBERS. TWIN WHEEL CASTORS (CASTOR WHEEL DIA. 50MM) & 700MM PITCH CENTER DIA (740MM WITH CASTORS) . 71 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood Upholstery Material Leather,Seat Material Leather Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)1140mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 1 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 72 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood,Upholstery Material Leather,Seat Material Leather,Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)2130mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 3 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 73 SUPPLYING AND PLACING Rectangular CENTRE TABLE with Marble Top of 1219mmX711mm,(DAISY/CT (W)1300mm X (D)650mm X (H)450mm),Specifications:Number of storage under top No storage,Top material,Tempered glass,Frame material No frames,Dimension of Top (Length X Breadth, or Diameter) ±20mm,762mmX457mm,Height of centre table ±10mm,410,millimeter,Thickness of top material (+/-2 mm)- 8 millimeterThickness of frame material (+/- 1 mm)-10 millimeter 74 SUPPLYING AND PLACING 14 SEATER oval MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II 75 SUPPLYING AND PLACING 6 Seater Sofa Material & Subtype-Premium Leatherette,Frame Material Solid Wood,Upholstery Material Premium Leatherette,Filling Material Foam,Silicone Fiber,Seat Material Premium Leatherette-Leg Material Solid Wood,Finish Matte,Colour & Colour Family Brown -Coffee Brown Dimension (W)4865mm X (D)960mm X (H)820mm,Seating -Capacity 3 Seater,seating Height 475mm,Size Standard 76 SUPPLYING AND PLACING9 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 4650 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 4650 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST,* CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATESt. 77 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM) 78 SUPPLYING AND PLACING Wooden Acoustic Wall Cladding/Panelling- Providing and fixing in position wood wall paneling of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing/wood veneer as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class 1, BS 476 part 7. The edges of the panels shall be tongued-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install Gel stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontalty using screws and plugs at spacing of 600mm centre-to-centre, Screw the aluminium channel (keel) vertically on channeled G.I stud 600mm 79 SUPPLYING AND PLACINGBlackout roller blind,Specifications-Mounting arrangement profile systems – clicked on hidden mounting clipsTypes of roller blind,Blackout roller blind-Shading solutionSingle roller blind – utilise one layer of fabric (called outer layer Operating mechanism-Side winders (that lock the manually adjustable blinds at different levels with the internal ratchet and tension adjusted by spring inside the tube) 80 Providing and Fixingof Drawers in Brown Finish ,Specification-Material : High QualityParticle board Dimensions (In Centimeters)-H 91 x W 90 x D 44 Dimensions (in Inches)-H 36 x W 35.5 x D 17.5 Primary Material-Engineered Wood as per Engineer incharge 81 Providing and FixingSTAGE - Providing & fixing raised stepped floor (Stage) Consisting ofMS Tabular frame work ofPipe Section (HOT ROLLED/COLD ROLLED) size 50mmx 50mmx2.0mm.tk. duly Painted with one coat of Red Oxide steel Primer, fabricated in module of 600 x 600 mm frame gid (as per Design or as instructed) with support of same section Legs /frame fixed on existing floor from base and raised at height minimum 150mm to max 200mm as required, from Existing floor. Vc providing and fixing 18mm thick heavy duty high density (1450 kg/cum) cement fiber Board fixed by SS. Screw on Horizontal & Vertical Surface on Existing Framework with one coated cement primer on Board and covering Board from top and sides by 2mm thick Vinyl flooring of approved make,colour and texture to be layed and fixed on sub floor smoothly finished and levelled by recommended adhesive cutting fixing and including covered raised portion of Board from all sides etc. complete,suitable for use up to the satisfaction of Engineer- in-charge.Design as approved by Engineer-In-charge. Base ofthe Vertical Legs of M.S. Frame (COLD ROLLED/HOT ROLLED) 82 Providing, fixing & installation MICROPHONE:-Flat frequency response across the vocal range for uncolored sound interchangeable cardioid, supercardioid, and omnidirec- tional cartridges that provide choices for applications Sleek, low-profile design for unobtrusive appearance Balanced transformerless output for increased immunity to noise over long cable runs-Compact Cinema Surround Speaker for Digital Applications:- Frequency range: 50 Hz to 20 kHz • High sensitivity: 91 dB SPL, IW @ 1m (3.3 ft) High power handling capability: 150 watts, continuous pink noise Internal Thermomaster• technology allows for unprecedented high frequency power in a compact, molded enclosure Convenient mounting design supports JBL QuickMountre, OmniMount• or APC multimount brackets Special cabinet shape incorporates 20• angled front baffle SMPTE/lS02969 Curve X high frequency de-emphasisMixer 8 input mono mixer XLR input switchable between mic and line level +/- 15dB gain trim control per input Input 1 is switchable to be pre/post master 24VDC or mains power operation Optional remote VCA/Tone generator/ Muting boards available • Whisper quiet operation 83 Supply, Installation, Testing and commissioning of microphone Delegate unit. 84 Supply, Installation, Testing and commissioning of microphone Chaiman unit, 85 Supply , Installation , testing and commissioning of Factory made 1.4HDMl Cable along with connector (15mtr length) 86 Supply , Installation , testing and commissioning of Factory made VGA along with Connectors.(15mtr length) 87 Supply , Installation , testing and commissioning of Factory made RCA along with Connectors.(15mtr length) 88 Supply , Installation , testing and commissioning 40W power Amplifier of following features:- Rated output wattage - 240W, amplifier output IOOV, 70V and 4-16 ohms transformer isolated speaker outputs, Supply input 0.775 v (OdB) unbalanced, 10k ohms, XLR and phone jack frequency 89 Supply , Installation , testing and commissioning10W wall mount speaker- Supplying, installation, testing and commissioning of 240W power amplifier with following features:- Rated output wattage- 240W, amplifier output 100V, 70V and 4-16 ohms transformer isolated speaker output, Supply input 0.775 v (0 db) unbalanced, 10k ohms, ZLR and phone jack frequency response 50 - 18000 Hz, +/- 1.5 dB, S/N ratio > 105 dB. 90 Supply , Installation , testing and commissioningCONFERENCE CONTROL UNIT, line Output 1 17.5V DC/3a Max.; -34dBV (20mV), line Output 2 17.5V DC/3a Max.; -34dBV (20mV), power Output 50w rMS at 2% THD, 90w Max. inputs 3xMic 0.65mV/4.7kQ Ixaux IOOmV/470kQ Frequency response 60-14,000Hz (± 3dB) 91 Supplying of Material & Subtype Engineered Wood Finish Matte,Colour & Colour Family Brown - Wenge Dimension (W)800mm X (D)384mm X (H)1970mm Size Standard,Style Contemporary,Assembly Type Knock Down 92 Supplying of Powder Coated Extruded Aluminium Sections Hybrid panel based system (combination of sliding & snap fit tiles) Modular Work Stations 93 Supplying of11 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823 94 SUPPLYING AND PLACINGSLOTED ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE)6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY, 95 SUPPLYING AND PLACING : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 96 Providing and fixing e Slimline Tower AC (2 Ton White),Availability of BIS/ISI Mark Certification for Split AC Floor type-Yes,Technology of air conditioner,Non Inverter AC-Nominal Marketing capacity as per BEE Star Rating Label (hint: 1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) (in Ton)-3 BEE Star rating of the product (Central Ministries/Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star (where usage is Limited)or higher Star R NA- Star rating for the capacity of >10,465 Watts (>9,000 kcal/hour) 97 Providing & Fixing 2.0 mm thick homogenous single layered vinyl flooring. The flooring shall be laid in manner to provide comfortable and jerk free surfaces including material, adhesive, scaffloding and lead and lift at all floor level etc. complete as per direction and approval of Engineer-in-charge. 98 Providing & Fixing Wiring for Primary Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insuate copperconductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point With 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Switch with Front plate and metal Box with all Accessroies for users. 99 Providing & Fixing Wiring for Secondry Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with all Accessories. 100 Providing & Fixing Wiring for Primary Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 101 Providing & Fixing Wiring for Secondry Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 102 Wiring for Primary Power point 6/16 Amp Switch-Socket Outlet with 4 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq-mm FR PVC insulated copper conductor Wire. Providing and fixing 1 nos 6/16A Socket controlled by 1 nos 16A switch with front plate and metal box with allAccessories. 103 Providing & Fixing Standing Bathtubs Specifications:Size:1690x800x445/565mm Free Standing Bath Tub with Over Flow & Drain 104 Providing & Fixing Corazzin Garden Patio Seating Chair and Table Set Outdoor Balcony Garden Coffee Table Set Furniture with 1 Table and 4 Chairs Set (Black) 105 Providing & Fixing Reliable Drapes Cotton Plain Door Curtains Reliable Drapes,Cotton GSM Quality-220,Lining included-No, Pack of-1,Length (Ft)-8.5-9,Width (Ft)-3-3.5 106 Providing MattressDimension 1981 mm X 1829 mm,Thickness of Core Layer (Height of Spring) 200 mm,Thickness of Felt (±1 mm) for Bonnell Spring 12 mm,Thickness of Top Layer (±2 mm)-50 mm Thickness of Bottom Layer (±2 mm)50 mm,Type of Spring in Core Layer Bonnell Spring (with cotton felt),Material of Top Layer Visco Elastic PU Foam (Memory Foam) 107 ProvidingCotton Pillow 33 cm x 56 cm (COTTON PILLOW)of Specification-BIS Marking ( For Body Casing fabric )-No Logo Marking-No,type of Logo,Stitched ( Patch Logo ),Agree to provide 108 Providing240 centimeter x C1112M 135 centimeter (L x W) Printed Bed Sheets(BED SHEET ):Technical Specification of the Product-Sheeting, Tickings and Bedsheets (V2) as per IS 175 BIS Certifcation-No,VarietyVariety - 2,Process of colouring Dyed,Matching Pillow cover 109 Providing 25 liter 3 Star Water Heater,25 Ltr 5 Star Water HeaterCapacity litres (Litres),BEE Star Rating (Central Ministries/ Departments while procuring shall ensure that the items carry 5 star or higher Star Rating of BEE)-3,Availability of Type Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification-No,Material of Inner Container Vitreous enamelled inner tank conforming to IS-13273 110 Providing Wall Mount Mesh Filter T-Shapped Kitchen-Chimney Material of Blower Body-Aluminium,Material of Blower Blade Aluminium,Material of Exhaust pipe-pvc,Filter Material,Stainless Steel,ShapeT-Shapped,Filter Type,Mesh Filter,Control Panel Type Soft Touch,Mount Type,Wall Mount 111 Providing Potable Water Purification System With Inbuilt Water Cooler. RO UV Aquaguard(Hot & Cold uv+ ro) Specifications-Flow rate (Litres/hr.)-12,Cold water storage capacity (Litres)-11 liter,Cooling capacity (litres/hr.)-4,Hot water storage capacity (Litres)-1.5 liter,Heating capacity (litres/hr.)-1.5,Cooling power consumption (Watts)-230,Heating power consumption (Watts)-550. 112 Providing300 L 3 Star Frost Free Double Door Refrigerator, of specification Cooling type:Frost free,Exterior body built:steel,Shelf material -Toughened glass,Voltage Range-160-300V,frequency-50 Hz 113 Providing900 mm wide 2000 mm high Metal Shelving Racks,Specifications :Type-OPEN TYPE Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted)-4,Shelves Material-0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,Depth in mm (±5 mm)-400,Width in mm (±5 mm)-900,Height in mm (±5 mm) 2000 114 Providing and fixing Drawers of Specification of Dimension (in cm)-H91 X W90 X D44in Brown Finish,primary material-Engineered wood,Weight 49.45kg 115 Providing and fixingDressing Table With cupboard and open shelves-Design of Dressing table With drawers,cupboard and open shelvesBase of dressing table Rectangular wooden frame Number of side mirror-1 number, Material specification-Prelaminated particle board of grade II type III of IS 12823/Latest.both side laminated. outer side laminated with shade matching with top shade and fascia shade and having balancing laminate of 0.5mm thick on other side Material thickness of complete body, Fascia and drawer/cupboard-19 millimeter,Material thickness for back, partition and drawer /cupboard bottom ± 2mm,19 millimeter 116 Providing and fixing Material & Subtype Solid Wood - Rubber Wood Table Top Material Solid Wood-Frame Material Solid Wood,Finish Glossy,Colour & Colour Family Brown - Walnut Dimension Of Table (W) 600mm X (D) 600 X (H) 610mm Dimension Of Chair (W)640mm X (D)530mm X (H)560mm Size Standard 117 Providing and fixing Wooden Double Bed Storage Box Opening From Material of Mattresses Panel-Other wood, Material of Bottom Panel of Storage Box-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Front, Back and side Panels Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Headrest Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Legrest-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest,Type of Bed-Wooden Double Bed Material of Bed Frame-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest 118 Providing and fixing 1 Seater Sofa With Leatherite Cover Sofa Set is Foldable to use as bed-No Backrest Cushion Material-Foam,density of Cushion of Backrest Material (Kg/Cubic M)-40 Covering Material for Seat and Backrest Fabric Frame Structure Material and size (±1 mm) Any other wood of minimum 25 mm thickness Seat Cushion MaterialFoam 119 Providing and fixing 8 SEATER Rectangular MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823/(Elanor Marble 8 Seater Dining Set) 120 Providing and fixing MODULAR TABLE L X D & H 2000 millimeter X 450 millimeter 700 millimeter (Alice TV Unit marble),Sprcification-Mode of Supply of modular table Knocked Down to be assembled at consignee site by the Seller Storage Provided one side,Number of storage unit-triple storage,Table Top material and thickness ±3mm-25mm thickness three layer pre-laminated Particle boards (Wood Product) of grade II Type II of IS 12823 Latest Gable end and modesty panel material and thickness-18 mm thickness three layers pre-laminated Particle boards (Wood Product) of grade II Type III of IS 12823 Latest 121 Supplying of Library Management Department. and NDL Softwares,Server Machines, Air-Condition Systems,Xerox Machines,Lamination Machines, CONNECTION)Binding Machines,Furniture/Furnishing. Computers, Printers,Computer System(with Internet Connection) 122 Supplying of Printer of Specification A Printing Technology Laser-Cartridge Technology,Composite Cartridge,Type of Printing Mono,Paper Size-A4 Print Speed per minutes per Department Incharge 123 Supplying of XEROX Machine(standard company) Type of MachineMultifunction Machine,Print Technology-Laser Type of Printing-Mono,Cartridge Technology Separate Drum and Toner (Dual Component) Platen/Flatbed Size-A3/A4,Paper Size (Original/Image)A3/A3 RAM size (MB)-4096as per Department incharge 124 Supplying of Determination of wavelength of He-Ne Laser light using Grating(Specification- Output Power: up to 15mW, CW - Wavelength: 632.8nm,* Mode Structure: TEM00 (>95%)* Beam size: <= 1mm* Beam Divergence: <= 1.5 mrad* Polarisation: Unpolarised, Vertical Polarisation. complete set up as per Department incharge 125 Supplying of Brewsters Law using spectrometer(Brewsters angle apparatus differ goniometer digital research bench polarizer analyser with rail type bench abron). complete set up as per Department incharge 126 Supplying of Determination of wavelength of Sodium light using Michelson interferometer(Power-3 kW,Usage-Physics Lab,Material-Mild Steel,Power Source,Electric Voltage 240 V). complete set upas per Department incharge 127 Supplying of Determination of wavelength of Sodium light using FabryPerot interferometer complete set up of Specification Flatness of Reflective Mirrors-λ/20 Diameter of Reflective Mirrors-30 mm Reflectance of Mirrors-95% Effective Travel of Preset Micrometer~ 3 mm Min Division Value of Preset Micrometer-0.01 mm Travel of Fine Adjustment of Movable Mirror-1.25 mm Resolution of Fine Adjustment-0.0005 mm Low-Pressure Sodium Lamp-20 W as per Department incharge 128 Supplying of Resolving Power of Telescope complete set up (specification Color-BlackMaterial-Plastic as per Department incharge) 129 Supplying of Resolving Power of Prism(Resolving power of telescope assists the user to know the basic principle of telescope. Fabricated using excellent quality metals, glass and plastic material, it is widely used instrument in scientific lab of colleges and research centers. It is known for accurate calculation and longer service life) complete set up as per Department incharge 130 Supplying of Production and analysis of Polarised light using half and quarter wave plate(Usage/Application Laboratory Voltage-230 V,Color-Black,Material-SS). Complete set up as per Department incharge 131 Supplying ofLogarithmic Amplifier(Built in power supply : +15V & -15V DC,Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet,Weight : 2KGS APPX) complete set up as per Department incharge as per Department incharge 132 Supplying of Zener diode characteristics & voltage stabilizer. Complete-Specification:(Voltage-240 V Frequency-60 Hz,Display Type -Analog)in all respect as per Department incharge 133 Supplying of FET characteristics complete up(Technical specifications-Inbuilt variable, overload & short circuit protected DC regulated power supplies of 0- 5 volt & 0- 15 volt.Voltmeter & ammeter are mounted on the front panel.One FET.Highly insulated front panel .Trainer helps to demonstrate the working principle of FET.Set of required number of patch cords.Multi - colored sockets are used.Housed in an elegant powder coated metal cabinet.Strongly supported by a comprehensive instruction manual complete with theory and operating details.LED indication for supply “ON” to work on 220V AC Mains.) as per Department incharge 134 Supplying of MOSFET characteristics complete set up(Specificaion:Power-AC Mains,Usage/Application-Laboratory Type-Analog,Material-plastic,Power Supply-ac mains, as per Department incharge 135 Supplying of UJT characteristics complete set up(Specification-Usage/Application-laboratory,Type-Analog,Display Type-Analog meters,Power Supply-ac mains)as per Department incharge 136 Supplying of Transistor biasing (CE mode)(Specificaion-Operating Power Supply-220VAC On Board Power Supply 0-1VDC & 0-10VDC Experiment Input & Output Char In CB & CE Mode OF PNP Tr.Meter Type Analog / Digital)set up as per Department incharge 137 Supplying of Characteristics of SCR(SpecificationUsage/Application-laboratory Type-Analog Automation Grade-Manual ,Power Supply-ac mainscomplete set up as per Department incharge 138 Supplying of Basic Logicgates and Universal gates. Operating Supply Voltage 230V,Logic Family-DIGITAL,Number of Inputs per Gate-2,Usage Laboratory,Material-ELECTRONIC Complete set up in all respect as per Department incharge 139 Supplying of Op-amp Integrator &Differentiator. Complete set up in all respect :Product Specification:Type-Analog Material-Metal,Automation Grade=-Manual,Color-black with multicolour PVC front panel,Power Supply-230,Capacity--5,connector Type-patch cord sas per Department incharge 140 Supplying of Half Adder, Full Adder and 4-bit binary Adder. Complete set up in all respect (Product Specification:Type-Digital,Display Type-Digital Interface--NO Material-ABS,Display-Digital,Pulse Generator-50Hz Variable Dc Output-no)as per Department incharge 141 Supplying of G. M. Counter for 6 digits GM counter with built in power supply complete set up(G.M.COUNTER: COMPLETE WITH INBUILT POWER SUPPLY EHT 250-1200v Workable on 220v. 50Hz., Power consumption 8W approx. STOP, START, RESET switches. Counts Capacity : 6 DIGIT COUNTING SYSTEM, Preset time : 3 DIGIT PROGRAMABLE TIMER WITH DIGITAL DISPLAY. 3 ½ Inbuilt Digital Volt Meter for GM TUBE Voltage. G.M.TUBE: END WINDOW G.M.TUBE MOUNTED IN ACRYLIC STAND. WITH ‘LEAD’ AND ‘ALUMINIMUM’ ABSORBENTS, Radioactive Source: ONE RADIOACTIVE SOURCE BETA or GAMMA (in Lead Container and wooden Box) SOURCE, . Dimensions : 460X370X230mm.(Complete instrument is HOUSED in corrugate box with Export Packaging) Wight : Total weight of the Instrument is 5.5kg.) as per Department incharge 142 Supplying of Measurement of Dielectric constants of solid and liquid samples complete set up(It Consists of following partsRF Generator (9-10MHz Approx) Micro Ammeter (Range 0-50mA) Potentiometer for Sensitvity Selection Fixed Capacity (Metal) Variable Gang Capacitor Socket for test Capacitor & Variable Capacitor brought out at front panel One Solid bakelite plate to be insert in gap of test capacitors)as per Department incharge 143 Supplying of Study of Dielectric constants and Curie temperature of ferroelectric ceramics Complete in all respect(Specifications Temperature Range : Ambient to 200°C,Display : 31/2 digit, 7 segment LED with autopolarity & decimal indicationResolution : 0.1°C,Accuracy : ±0.5°C (typical),Stability : ±0.1°C Power : 150W,(ii) Digital Capacitance MeterThis a compact direct reading Instrument for the measurement of capacitance of the sample. Specifications,Range : 50-6000 pf,Resolution : 1pf Display : 3½ digit, 7 segment LED, Typical results obtained with the above set-up are as shown in the graph) as per Department incharge 144 Supplying of Determining Optical constants of a metal by reflection of light Complete in all respect (Specification-Power-AC Mains,Usage/Application-Laboratory,Type-Digital Material-Metal,Automation Grade Manual,Color-White Power Supply-AC Mains,Display Type-Digital) as per Department incharge 145 Supplying of Lattice dynamics kit with frequency meter (Technical Specifications: Audio Oscillator 100 khz,Built in Power Supply and Output Stage to match the Impedance of Simulated Lattice,Lattice DynamicKit consists of Transmission line, which Simulates One-Dimensional Mono-AtomicandDi-atomicLattices,. LCD Based Frequency Counter is Provided on panel to Measure Frequencycomplete set up as per Department incharge 146 Supplying of BCD to seven segments complete set up(Specification:Built in power supply : +5V DC Mains : 230V AC Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX) as per Department incharge 147 Supplying of Monostable Multivibrator using Oscilloscope (CRO) complete set up (Specification:Usage/Application Laboratory Packaging Type-Corrugated Box,Connector-2mm sockets Frequency Range -50Hz) as per Department incharge 148 Supplying of Bistable multivibrator using Oscilloscope(CRO))Technical Specification:(Built in power supply : +12V & -12V DC Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX)complete set up as per Department incharge 149 Supplying of Pulse code modulation and demodulation complete setup (Product Specification,Type Laboratory Trainer Kit Usage/Application-Laboratory,Accuracy-+/- 10%,Frequency-50 Hz Input Voltage-220V,Packaging Type-Corrugated Box,Power Source-ElectricShape-Rectangular,Material-ABS or Metal Cabinet)as per Department incharge 150 Supplying of Addition, Subtraction, Multiplication using 8086 microprocessor(Product Specification,Usage/Application-LaboratoryType-Fully Automatic,Automation Grade-Semi-AutomaticClock Frequency-Yes,Color-Green,Display-Digital Packaging Type-Corrugated Box, Power-200-400 Weight 2 Kg) as per Department incharge 151 Supplying of Thevenin theorem, (THEVENIN’S AND NORTON’S THEOREM APPARATUS,Technical specifications Inbuilt fixed DC regulated power supply of 12 volt. Voltmeter & ammeter are mounted on the front panel. Resistive network is used in the circuit. Circuit diagram is printed on highly insulated front panel . Trainer helps to demonstrate the working principle & verification of Thevenin’s & Norton’s Theorem based on resistive circuit. Student can calculate & measure the value of current & voltage for different load circuits. Calculation of power consumed by the circuit. Facility for connecting external Power Supply. Set of required number of patch cords. Multi - colored test points are provided in the circuit to observe voltages at different points. Housed in an elegant powder coated metal cabinet. Strongly supported by a comprehensive instruction manual complete with theory and operating details. LED indication for supply “ON” to work on 220V AC Mains. Circuit protection through glass fuse)Complete set up as per Department incharge as per Department incharge 152 Supplying of Active filter set up(Product Specification Operating Temperature-0-50,Frequency (Hz) 50,Condition-New Temperature (deg. Celsius)-50,Usage/Application Industrial, Educational, Residential, Commercial) as per Department incharge 153 Supplying of A to D counter type complete set up (Product Description-M-32 AD M-16 AD,Input AD: 1/4 TRS jack and 25 pin D-sub, servo balanced, completely symmetrical audio path, Output AD: 4 x ADAT optical, 1 x MADI optical/coaxial,Dynamic Range AD: 113 dB RMS unweighted, 116 dBA,THD AD: < -110 dB (< 0.00032 %),THD+N AD: < -104 dB (< 0.00063 %) Crosstalk AD: > 130 dB,Input level for 0 dBFS: +24 dBu, +19 dBu, +13 dBu,Frequency response AD, -0.1 dB: 10 Hz - 23.2 kHz (sf 48 kHz),Frequency response AD, -0.5 dB: < 5 Hz - 45 kHz (sf 96 kHz) Frequency response AD, -1 dB: < 5 Hz - 80 kHz (sf 192 kHz) Sample rates: 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (Sync/WC),Jitter: Typical < 1 ns for internal, Word Clock, ADAT and MADI input Jitter sensitivity: all PLLs operate error-free even at 100 ns,Jitter suppression: > 30 dB (2.4 kHz),Power supply: Internal switching mode PS, 100V - 240V AC, 60 Watt Dimensions: (WxHxD) 483 x 88 x 200 mm)as per Department incharge 154 Supplying of Determination of Plancks constant(1. 1 0-2V D.C. at 20mA Variable Power Supply. 1.2 Digital Panel meter 3½ digits range 2mA. 1.3 Digital Panel meter 3½ digits range 2 volt 02 Lamp House: 100W Bulb with stand 03 Vacuum Type Photo Cell : Mounted in a Iron box. 04 Three different colour optical filters 05 Adequate no. of patch cords stackable 4mm spring loaded plug length 50cm. 06 Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.) as per Department incharge 155 Supplying of Determination of Energy Band Gap using Four Probe method(Product Specification:Type-Energy Band Gap Usage/Application-Laboratory,Connector-4mm Banana Socket Frequency-50Hz) as per Department incharge 156 Supplying of Determination of Hall coefficient and Hall angle in Hall-effect(Product Specification,Display Type-0-20V DC, 0-5 A, digit LED, Primary safety socket,4mm Electro Magnet Coils 500 T, Voltage resolution -0.1V,Current Resolution 0.1 A) as per Department incharge 157 Supplying of Determination of magnetic susceptibility using Guoys method(Usage/Application Physics Laboratory Type Of Instruments-Magnetic Susceptibility Gouys Balance Method Experiment Setup,Power-230V , 50Hz, +-10% Display Type-LED Type) as per Department incharge 158 Supplying of Study of absorption pattern of a given sample using FTIR spectrometer(Product Specification,Detector-High performance pyroelectric infrared detector,Weight-15 kg Software-1,Voltage-100-240V AC,Electronic System-24bit A/D converter at 500KHz, USB 2.0,Wavenumber Range-7800~350 cm-1Power-100-240V AC,50/60Hz,Signal Noise Ratio-30000:1 (resolution@4cm-1 , sample and background scan for 1 min@2100cm-1 ),Light source-Long life, steady state infrared emitter Beam splitter-coated KBr,Resolution-1 cm-1,Dimension-430mm x 360 x200) as per Department incharge 159 Supplying of LCD Projector and smart board (Product Specification,Projection Distance-<1 m Resolution-WXGA,Lamp Life-5000/9000/10000 HOURS Screen Size-100,Display Type-LCD,Dimensions-400X367X149MM Connectivity Type-Dual HDMI, HDMI,Brightness-2000-4000 Lumens Color-White) as per Department incharge 160 Supplying of Desktop(ntel Core I3/ 10th Gen/ 4GB RAM/ 1TB HDD/ DOS/ NO DVD/ 19.5 Inch Monitor/ 1 Year Warranty) as per Department incharge 161 Supplying of Printer(Product Specification,Printer Type-Ink Tank Color Output-Color,Print Speed-22 ppm,Paper Size-A4,Dimension-403 x 369 x 150 mm,Weight -6,Warranty-One Year or 50,000 pages which ever is earlier) as per Department incharge 162 Supplying of Printer (Product Specification Printer Type-Inkjet Color Output-Color | B&W,Print Speed-10,Paper Size-A4,Connectivity-USB,Dimension-377 x348 x179,Weight-3.9 Print Volume-any)as per Department incharge 163 Supplying of XEROX Machine (Product Specification,Functions-Photocopy,Supported Paper Size-A3,Supported OS-Windows 10 Color Output-Black & White,Number Of Trays-1,Item Color-Black & WhitePrint Speed-22 PPM,Weight-40 kg,Print Technology-Laser Input Tray Capacity-350 sheets,Warm-Up Time-5.6 Sec,Duty Cycle-80000 / Month,Resolution-600 x 600 dpi Connectivity-Ethernet & USB,Duplexing-Yes)as per Department incharge 164 Supplying of computer system with internet connection,PC Specifications to be followed :Processor Intel Core i5(10th Gereneration or newer ),RAM-8 GB or Higher HDD:512 GB,SSD,Monitor 24 LCD Monitor .OS:Windows 10 Professional ,Anti virus:User Licence for one year as per Department incharge 165 Supplying of Laptop (with Internet connection),Processor intel Core i5(11th Generation or newer),RAM 8 GB or higher HDD:512 GB,SSD Monitor 14 screen ,OS Windows 10 Professional ,Antivirus :User Licence for one year 166 Supplying of LCD Projector (Specification-Brightness:2000-4000 Lumens,Resolution-FULL HD 1080P,Connectivity Type-Dual HDMI, HDMI Display Type-DLP,Power Supply-100-240V Portable-Yes) as per Department incharge 167 Supplying of Smart Board (Frame Material-Aluminium Usage/Application-School, Education, etc,Effective Touch Area-72 x 48 inch Material-Ceramic Input Method-USB Power Consumption-150 - 220 W,Shape-Rectangular) as per Department incharge 168 Supplying of MS Suite Software(Specification-Microsoft Office Software,Operating System:For Windows,Brand:Microsoft )as per Department incharge 169 Supplying of Adobe Photoshop Software(Specification -Graphic Design and Photo editing,Licence-1 yea) as per Department incharge 170 Supplying of windows10 OS Software(Specification-License Duration-Life Time,Architecture-32/64 Bits,Operating System For WindowsAlso Provides,Windows Operating System,Provide Installation Service-Yes Support 24/7 (Live Rep)) as per Department incharge 171 Supplying of Laptop of 11th Generation intel core i3,1115G4 processor (6 MB Cache up to 4.1GHZ)windows 10 Home Single language English,intel UHD Graphics with shared graphics memory 8GB ,8 GBX1,DDR4,3200 MHZ,512 MB,2 PCLeNVMe Solid state drive pebble (Top colour is pebble colour,Base and palmrest are black colour as per department incharge 172 Supplying of Desktop of 10th Generation intel core i5-10500T (6 CORE,12MB Cache 2.3GHZ to 3.8GHz,35W ),Windows 10 Pro (64 Bit )English,intel integrated graphics),8GB ,1X8 GB,DDR4 non-EC0C Memory,2.5 inch TB 7200 RPM ,SATA Hatd disk drive 5480AJO 23.8 FHD 1920X10080 ips non touch,Antiglare camera,integrated graphics,Bronze 1505w PSU as per department incharge 173 Supplying of Printer (Specification:Item Weight-12 Kg,Package Dimensions-60 x 56.5 x 38 cm,Connectivity Type-Wi-Fi Operating System-Windows)as per department incharge 174 Supplying of Fumehood(Specification:Type-exhaust,LED-Tube fitting,Power-230 volt,Working Top-Granite ,MOC-GI with PU coated Storage includedas per department incharge 175 Supplying of electronic balance(Specification -Usage/Application-Laboratory,Accuracy-0.01%,Calibration-Fully Automatic,Type Of Weighing Scale-Digital,Voltage-110-220 V Mounting Type Desktop) as per department incharge 176 Supplying of Magnetic stirrer Magnetic stirrer Hot plate (Specification-Weight-2.3 kg,Timer -999 minutes,Temp. Accuracy-+-1 Deg.C(<100 Deg.C)+-3 Deg.C(<300 Deg.C),Dimensions LxWxH (mm)-230 x 180 x 120,Max.Temp. (Plate Surface) 300 Deg.C,Power supply-AC 220V / 50 Hz,Top Plate Size 135 x 135 mm,Display-LCD,Max. Volume (ml) 2000 ml,Speed (RPM)-1250 RPM Plate Material Steel per department incharge 177 Supplying of HOT Air oven of made inner material-stainless steel,Outer material -mild steel ,Surface treatement -Powered coated ,Sizes-Different sizes,Gravity conviction type-Double wall.Mechnical conviction -Triple wall as per department incharge 178 Supplying of colourimetry , Ery colour colorimeter industrial and research purpose stability( Product Specification:Material-Aluminium Alloy,Automation Type Automatic,Brand -DD-LAB ,Dimension-210 x 160 x 80 mm,Display Type-Dual Digital DisplayLight Source-Highly Accurate Laser Source,Stability- + 0.02 O.D. Per Hour Volume 1 ml. minimum,Filters layer-Built in 9 Digital filters 30,000 hours Life,Weight-1.5 Kg,Battery Backup-6 V Ni CD Re-chargeable Battery,Detector Silicon Photo-diode,Display Model Absorbance & Wavelength,Filter Wavelength 680 NM Country of Origin Made in India) as per department incharge 179 Supplying UV-Vis Spectrophotometer Fully touch screen portable UV Spectrophotometer shimadzu model name:UV 1900,Brand :shimadzu,Display =fully touch screen,Type-portable,size 450x501x244 as per department incharge 180 Supplying of potentiometer ,Range-0 to 1999.9mv,Resolution-1 mv,Repeatability -1mV,Accuracy +1 mv+ digit,Input impedency-10ohms,operating temperature 10 to 50 degree Celsius,Display 1/2 digit 0.5 seven segment LED Display indication,Power-230V+10,50hZ,Dimensions 76x275x170 mm,weihjt 2 kh as per department incharge 181 Supplying of Conductivity meter,LT 26 Deluxe conductivity meter,Product details:Model no-LT-26,Brand -Labtronics,Usage-Laborataty,Display type 3.5 Digit LEDas per department incharge 182 Supplying of Online COD/BOD Detector analyzer warer quality monitoring probe,Measure range-0-200/0-1000mg/l,Resolution -1 mg/l ,Accuracy +5%F.s ,Under pressure-1 bar,Power supply -12-24V DC ,Temperature range 0-45 degree ,Production leve;-IP68 as per department incharge 183 Supplying of melting point appratus,Temperature renge -2 degree above ,Readability 1 degree ,Display -3 Digit LED,Heating rate control-Electronic,Temperatre sensor PT-100as per department incharge 184 Supplying of Ph meter Labrtonics,Range:0-14pH,Resolution:0.01pH,Accuracy:0.01pH(Relative),Temp comp:Automatic wvith temp probe,Buffer:Manuals with keys as per department incharge 185 Supplying of Spectrum 3 FT-IR Spectrometer,Model no.-LI280127,Wave length -11000-30 cm-1 as per department incharge 186 Supplying of Stopwatch NIVIA 600 plastic(Product Specification:Color-Black,Usage/Application-Sports,Time Display 12/24 hour display for user option,Material-Plastic,Dial Shape-OvalMaximum Counting-23 hours 59 minutes 59 secondsas per department incharge 187 Supplying of Digital Bomb Calometer(Specification-Auto Off Automatic,Frequency-50 Hz,Voltage-230-280 V,Operating Time Per Test 10 minutes,Power Source Electric(Automatic) as per department incharge 188 Supplying of Microprocessor viscometer ,Product details: Measuring range-101x105mpa,,Spindles-4 Spildles,Rotor speed(rpm)-6/12/30/60 rotor speed rpm as per department incharge 189 Supplying of Flame photometer,Product details:Application-Laboratory use,industialuse,,weight 705kg ,Curve fit accuracy,Resolution-0.1ppm/meq as per department incharge 190 Supplying ofwater purification system,Resolution-18.2 M ohm cm at 25 degree C,Weight-19.5kg,Frequency-50-60Hz as per department incharge 191 Supplying of Refrigerator of 7.5kg fully Automatic Top Load washing machine (Hard water wash,Grey,5 star,10 years warranty as per department incharge 192 Supplying of water bath ,unstirred water bath s ,Digital info Water bathdigital,18L amb+5 tp 99 degree C includes clear lid and base trayas per department incharge 193 Supplying ofmini rotary shakers 50to 400RPM,features-220/230 V ac,Power supply-50-60Hzas per department incharge 194 Supplying of Magnetic stirrer- capacity 5 litre Spinit Digital Magnetic Stirrer Features-Type of Product-Magnetic stirreras per department incharge 195 Supplying of Digital ultrasonic cleaners (Specification: tank capacity 4 L, ultrasonic power 100W, Heating, Power-100W, time setting 1-99 min, heating temp up to 80 degree, in and out both in ss, with digital timer auto stop of sonication. 230V AC +-10% 50HZ. Tank size 300x150x100mm, overall size 330x180x240mm.supplied with basket and Lid.) as per department incharge 196 Supplying of Calomel electrode (Product Specification:Packaging Type-Box.,Length-120 mmUsage-Electrochemical Study(Laboratory))as per department incharge 197 Supplying of Pt-wire counter electrode (Product Specification Electrode Diameter-0.5 mm,Power Source-10A) as per department incharge 198 Supplying of UV-LAMP Cabinet(Product SpecificationSize/Dimension-15 X 12 X 10 (H) Light Source-3 NOS , SHORT WAVE -254nm-1no, LONG WAVE-365nm, VISIBLE LIGHT,Material-MILD STEEL,Voltage 230 V AC) as per department incharge 199 Supplying of Magnet (Magnet Grade-N48 Shape-Cup & Pot,Material Neodymium,Dimensional Tolerance+-0.05 mm,Plating / Coating-Ni-Cu-Ni Colour-red,Surface Gauss 3000 Gauss,Maximum Working Temperature (Deg. C)-230 Deg. C as per department incharge 200 Supplying of Micro Centrifuge tube(Specification: Usage/ApplicationLaboratory Analyzers,Material,Polypropylene Color-White,Pack Contains--20 Packet / carton & 500 pcs / packet,Shape-Conical,Length-4.1 cm,Inlet Diameter-1.3 cm Capacity2 ml)as per department incharge 201 Supplying of Micropiprtte(10-100uL),(Product Specification Capacity-10 ml,Volume Increment -0.1 microlitre Material-Glass,Autoclavable-Yes)as per department incharge 202 Supplying of Micropiprtte(10-1000uL),( Product Specification Material-Plastic,Capacity-Up to 1000ul,Color-Transparent Usage/application-Chemical Laboratory) as per department incharge 203 Supplying of printer-Black and white print ,scan,copy all in one printer Product Specification Print Speed-Up to 18ppm / 19ppmLaser Printer,Color Output-Black & White,Print Technology LaserjetUsage/Application-Printing,Supported Paper Size-A4 Compatible Operating Systems1,Windows 8,Windows 7,Windows Vista,Windows XP,Windows 2000,Mac OS X 10.4 - 10.8,Linux*3 Print Resolution-Up to 600 x 600DPI,1 200 (Equivalent) x 600DPI,Print Language-UFR II LT Dimension-372 x 371 x 254mm (With the Cassette Opened)Weight(W/O CRG)-7.6kg,Monthly Duty Cycle-8000 Pages Power Consumption 960W(Maximum),First Printout Time7.8s / 7.7s (A4 / LTR),Zoom 50 - 200% in 10% Increments Refill Type Toner Cartridge,Internal Memory 64 MB Printer Language UFR II LT (Host Based),Paper Weight 60 to 163g/m2 (Cassette),Copy Speed Up to 18 / 19Cpm (A4 / LTR) Halftones 256 levels,Copy Resolution 600 x 400 DPI Display 7 - Segment,1 - Digit LED as per department incharge 204 Supplying of printer-colour print ,scan,copy all in one printer (Specification :Functions-Print | Scan | Copy,Technology-Inkjet Color output-Color | B&W,Connectivity-Wireless(Wi-Fi) Usage-For Office ,Paper size-A4,Print speed upto 40 pages/min)as per department incharge 205 Supplying of photocopier branded fast print 50ppm high image resolution superior print quality,fast scan up to 50ppm A4 Monocolouras per department incharge 206 Supplying of LAN.Networking,cabling,switches,Wi-Fi points(10 points in each department) as per department incharge 207 Supplying of installation of Printer (Black and white),Printer( colour),Photocopier and LAN,Networking,Cabling,Switches,Wifi Points as per department incharge 208 Supplying of RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio as per department incharge 209 Supplying of Freightof RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio) as per department incharge 210 Supplying of wall mount (Dimension long:Telescopic Adjustable CCTV camera mounting bracket -Color: Beige Universal Camera Bracket, Heavyduty weatherproof iron bracket fits mostbrands of outdoor camera housing,Iron stand Platsic APPLICATION: Ideal for indoor outdoor dome cameras, Security Camera Mount Bracket, high quality with professional design,more stable and reliable.Hidden hole: Cable can feed thru L bracket tothe housing thus provide cable protection Outdoor and Indoor Use.)as per department incharge 211 Supplying of Camcorder Compact full HD ENG Camera with 20X zoom and 5 axis image stabilization. 20X optical zoom (26.8mm, F/1.8-576MM, F/2.;28.8MM, f/1.-576mm). 5 axis image stabilization. Support formats: full HD50P/60P, AVCHD/MP4;SD card slots 2 35mm film camera equivalent when dynamic IS is turned on with Tripod as per Department Incharge 212 Supplying of Video capture and video capture card (Product Specification:Converter type-USB,Material:Metal,Audio Jack:3.5 mm,HDMI Version:Hdmi-1.4,Audio:44100 AU,Video:Full HD Frame:48000 Resolutions)as per department incharge 213 Supplying of UPS(1KVa)(Product Specification: Type-Online UPS,Capacity-1 kVA,Configuration-1 Phase IN - 1 Phase OUT,Protection-OverVoltage,Form Factor-Tower Model Back Up Time-20- 30 Mins,Frequency-40 ~ 70 Hz (auto-sense) Usage/Application All) as per department incharge 214 Supplying of Studio light-125watt,5 LED BULBS consisting of 25watt bulb(Colour Temperature:5500 kelvin)as per department incharge 215 Supplying of Live streaming software for live streaming or live telecast as per department incharge 216 Supplying of Cables,installation,SSD Card(SAMSUNG VNAND SSD 850 EVO 2.5 250GB SATA III 3-D Vertical Internal Solid State Drive (SSD) MZ-75E250B/AM) as per department incharge 217 Supplying of complete making soundproof class(20*20 feet Room) as per department incharge 218 Supplying of RFID Tags RFID Book Lables(specification: Language ‏ : ‎ English,Simultaneous device usage ‏ : ‎ Unlimited Text-to-Speech ‏ : ‎ Enabled,Screen Reader ‏ : ‎ Supported Enhanced typesetting ‏ : ‎ Enabled,X-Ray ‏ : ‎ Not Enabled,Word Wise ‏ : ‎ Not Enabled) as per department incharge 219 Supplying of Anti theft stickers with the university logo(Polycarbonate 175 Microns Matt Finish) as per department incharge 220 Supplying of Middleware Application Desktop(writing and read tags) as per department incharge 221 Supplying of RFID Staff station or desktop reader (used for Tagging of books and circulation) operations through RFID as per department incharge 222 Supplying of Integration with software and Training of complete RFID System as per department incharge 223 Supplying of Data Encoding,Booking Tagging and Registration per book as per department incharge 224 Supplying of RFID Secuity Gates (2 pedestals - 1 gate),RFID Secuity Gate(Provide Installation Service-Yes,Support-24/7 (Live Reporting Language Support-English) as per department incharge 225 Supplying of Automated book drop box (ntegrated RFID Reader • Approx. 250 Books Receiving Cart (Movable) • Client Software for Checking-in Facility and communicating with LMS with provision for E-mail/SMS confirmation • Has automatic hutch which should open only on valid RFID tags and close once the book has been accepted to prevent the patrons from removing checked in books. • Communication with any LMS Software through SIP2/NCIP protocols • Compliant with internationally recognized standards for RFID based library self-services systems. • Book Drop can display item ID once item is returned. • Enabled with necessary items i.e.: Branded CPU etc. • 15” or higher LCD/LED Touch Screen Monitor. • Ethernet High Speed Receipt Printer (Reputed/Branded) • Customizable Design matching the library aesthetics; Contemporary and attractive. • Design is such that there is not damage to the dropped books. • Library Ethernet network and wireless network compliant. • Optional Features: Fingerprint Scanner, Smart Card Readers etc) as per department incharge 226 Supplying of 5KVA Invertor -online UPS with battery back up 100Mah battery (8 units)(Product Specification,Capacity-1100 Voltage-130V ,Rated Input Power-5 KVA,Display-Digital Type-Square Wave Inverter Country of Origin) as per department incharge 227 Supplying of LAN,Switches,Necessary cabling,casing,power supply port including cables as per department incharge 228 Supplying of Installation charges of RFID Tags,Anti-theft sticker,Middleware Application Desktop,RFID Staff statio,Integration of software,Data incoding books,RFID Secuirty Gates,Automated Book Drop Box,Cabling,Casing,Wiring,Switches,LAN as per department incharge 229 Supplying of Air conditioning 1.8Ton heavy duty AC (minimum 3 star rating,Coil material -copper,Power consumption-1950W,Power Requirement -AC 130-285V, 50Hz) as per department incharge 230 Supplying of Desktop,i5 processor ,7th Generation,500GB HDD,4GB RAM,23.8 INCH LED Backlit Monitor,Full HD IPS Panel(Brand-HP,Dell,Acer) as per department incharge 231 Supplying of Headphone with built in microphone,(Communication-Wired) as per department incharge 232 Supplying of 75 diagonal length with 3 GB RAM and 48 GB ROM ,Slim frame anti glare glass.3M Antiglare ,H7 Touch surface hardness,Light weight for easy installation as per department incharge 233 Supplying of Dedicated server-HPE Proliant DL 380,Gen 10 5218.2.3GHz 16core ,1P-32GB-R P408ianNC 8SFF 800WPS Server,Intel xeon G5218 Kit for DL 380,Gen 10 as per department incharge 234 Supplying of 5.5KVA Inverter with battery backup,Microtek inverter,online UPS ,65Mah battery(16 unit )-Exide as per department incharge 235 Supplying of Freight Transportation Charges of Desktop,Headphone,LAN Switches,4K-OPS,Dedicated server,5.5 KVA Inverter with battery back up and Air conditioner as per department incharge 236 Supplying of 86 Diagonal interactive display,3 GB RAM,48 GB ROM,4K Display Android model,Slim framenAnti glare Glass,H7 Touch Surface hardness ,Light weight for easy installation ,Media Suits for Annotation softwatr bundled with education Apps as per department incharge 237 Supplying of 4k OPS i5,7th Gen,8GB RAM,128 GB SSD as per department incharge 238 Supplying of play mounting including white board & Green board,Material post formed ply,Size 15ft(length)x7ft(ht) with green board for chalk,whiteboard for marker and cupboard as per department incharge 239 Supplying of UPS (1KVa,Phase-Single phase.Back up Time 10-20 min,Frequency-50Hz) as per department incharge 240 Supplying ofTraining and installation of 86 diagonal interactive display,4k-OPS,Play mounting including white board & Green board and UPS of 1KVA as per department incharge 241 Supplying of Digital Podium PTGN 500 Windows 8.1 LCD ,Electronic Lectern,On site OEM Warranty in 3 yearsas per department incharge 242 Supplying of PA System sound system with amplifier 350 watt ,30 watt speaker (4 nos) as per department incharge 243 Supplying of wireless mic Dual channel cordless microphone as per department incharge 244 Supplying ofTraining and installation of Digital Podium,86 Diagonal interactive display (4k display),4K-OPS,Play mounting including white board and green board,5KVA invertor,PA System and wireless mic as per department incharge 245 Supplying of Desktop :- 1).i5 Processor, 7th Generation, 500GB HDD, 4GB RAM, 2).23.8 inch. LED backlit Monitor Full HD IPS Panelas per Department Incharge 246 Supplying of 55 LED Display for CCTV Branded LED Display as per department incharge 247 Supplying of CCTV Camera IP based CCTV camera,2 TB Space with NVR with necessary accessories as per department incharge 248 Supplying of Stagmometer as per Department Incharge 249 Supplying ofViscometer as per Department Incharge 250 Supplying of Beaker-50ml as per Department Incharge 251 Supplying of Beaker-100ml as per Department Incharge 252 Supplying of Beaker-250ml as per Department Incharge 253 Supplying of Beaker-500ml as per Department Incharge 254 Supplying of Beaker-1000ml as per Department Incharge 255 Supplying of Buchner Funnel 3 as per Department Incharge 256 Supplying of Buchner Funnel 6as per Department Incharge 257 Supplying of Burette-50ml as per Department Incharge 258 Supplying of Chromatography column 1x18 with stop cock as per Department Incharge 259 Supplying of Conical flask-100ml as per Department Incharge 260 Supplying of Conical flask-250ml as per Department Incharge 261 Supplying of Conical flask-500ml as per Department Incharge 262 Supplying of Conical flask-1000ml as per Department Incharge 263 Supplying of Flat Bottomflask-500ml(Round) B-24 socket as per Department Incharge 264 Supplying of Round bottom flask-50ml Joint B-24 as per Department Incharge 265 Supplying of Round bottom flask-100ml Joint B-24 as per Department Incharge 266 Supplying of 3 neck RB flask B-29,B-19.as per Department Incharge 267 Supplying of Condenser Spiral B-24 and, B-19 as per Department Incharge 268 Supplying of Condenser Spiral B-24 and, B-24 as per Department Incharge 269 Supplying of T-type tube as per Department Incharge 270 Supplying of Rubber Cock No. 10 as per Department Incharge 271 Supplying of Specific Gravity hydrometer 800-1000 as per Department Incharge 272 Supplying of Specific Gravity hydrometer 100-1200 as per Department Incharge 273 Supplying of Universal hydrometer 1000-2000 as per Department Incharge 274 Supplying of Measuring Cylinder-10ml as per Department Incharge 275 Supplying of Measuring Cylinder-50ml as per Department Incharge 276 Supplying of Measuring Cylinder-100ml as per Department Incharge 277 Supplying of Measuring Cylinder-500ml as per Department Incharge 278 Supplying of Measuring Cylinder-1000ml as per Department Incharge 279 Supplying of Measuring Cylinder-2000ml as per Department Incharge 280 Supplying of Measuring flask-100ml as per Department Incharge 281 Supplying of Measuring flask-500ml as per Department Incharge 282 Supplying of Measuring flask-1000ml as per Department Incharge 283 Supplying of Pipette-0.5ml as per Department Incharge 284 Supplying of Pipette-2ml as per Department Incharge 285 Supplying of Pipette-5ml as per Department Incharge 286 Supplying of Pipette-10ml as per Department Incharge 287 Supplying of Pipette-25ml as per Department Incharge 288 Supplying of Separating Funnel-250ml B-24/B-24 as per Department Incharge 289 Supplying of Spatula Flat Spoon 6as per Department Incharge 290 Supplying of Spatula Flat Spoon 5as per Department Incharge 291 Supplying of Stop Cork 2wayas per Department Incharge 292 Supplying of Silica crucible-15ml without Lid as per Department Incharge 293 Supplying of Silica crucible-25ml without Lid as per Department Incharge 294 Supplying of Stalagmometer Straight Graduated as per Department Incharge 295 Supplying of Chemical thermometer 10c-110c as per Department Incharge 296 Supplying of Chemical thermometer 0c-250c as per Department Incharge 297 Supplying of Tiration flask-100ml as per Department Incharge 298 Supplying of Tiration flask-250ml as per Department Incharge 299 Supplying of Tongs crucible S.S.8 as per Department Incharge 300 Supplying of Test tube holder as per Department Incharge 301 Supplying of Filter Flask-500ml as per Department Incharge 302 Supplying of Filter Flask-1000ml as per Department Incharge 303 Supplying of Watch glass 3 as per Department Incharge 304 Supplying of Watch glass 4 as per Department Incharge 305 Supplying of Watch glass 6 as per Department Incharge 306 Supplying of Wire gauge150x150mm as per Department Incharge 307 Supplying of Tripod stand 8 as per Department Incharge 308 Supplying of boiling Test tube 1x8as per Department Incharge 309 Supplying of boiling Test tube 2x8as per Department Incharge 310 Supplying of Reagent Stickers 2x1 as per Department Incharge 311 Supplying of Ordinary Filter paper as per Department Incharge 312 Supplying of Reagent bottles-250mlas per Department Incharge 313 Supplying of Rubber cork as per Department Incharge 314 Supplying of Rubber tube 6mm as per Department Incharge 315 Supplying of Solid Reagent bottle-125mlas per Department Incharge 316 Supplying of Stopwatch plastic body as per Department Incharge 317 Supplying of Test tube stand 12 holes as per Department Incharge 318 Supplying of Thermometer 360 as per Department Incharge 319 Supplying of Test Tube 6mmx15cmas per Department Incharge 320 Supplying of Test Tube 10mmx10cm as per Department Incharge 321 Supplying of China dish 3 as per Department Incharge 322 Supplying of China dish 4 as per Department Incharge 323 Supplying of Brushes for Test Tube as per Department Incharge 324 Supplying of Brushes for Burette as per Department Incharge 325 Supplying of Brushes for Conical flask as per Department Incharge 326 Supplying of LPG gas burner as per Department Incharge 327 Supplying of Condenser Coil 12 as per Department Incharge 328 Supplying of Receiving adopter with vacuum outlet as per Department Incharge 329 Supplying of Plastic Wash bottle-500mlas per Department Incharge 330 Supplying of Pastel and Mortar 3 as per Department Incharge 331 Supplying of Pastel and Mortar 4 as per Department Incharge 332 Supplying of Pastel and Mortar 6 as per Department Incharge 333 Supplying of China Clay 2 as per Department Incharge 334 Supplying of China Clay 3 as per Department Incharge 335 Supplying of China Clay 4 as per Department Incharge 336 Supplying of Petri Dish 3(Borosil) as per Department Incharge 337 Supplying of Petri Dish 4(Borosil) as per Department Incharge 338 Supplying of Distillation Set-Complete flask-500ml as per Department Incharge 339 Supplying of Distillation Set-Complete flask-1000ml as per Department Incharge 340 Supplying of Thermometer Pocket B-14 as per Department Incharge 341 Supplying of Sintered Glass Funnel-25ml as per Department Incharge 342 Supplying of Air Condenser 12 as per Department Incharge 343 Supplying of Burette Stand with Clamp as per Department Incharge 344 Supplying of Cork borer as per Department Incharge 345 Supplying of Capillary Tube for melting point as per Department Incharge 346 Supplying of Dessicators 6 as per Department Incharge 347 Supplying of Dessicators 8 as per Department Incharge 348 Supplying of Dropper with Rubber teats 6 as per Department Incharge 349 Supplying of Dropper 4(Borosilicate glass) as per Department Incharge 350 Supplying of Dropping bottle-125ml as per Department Incharge 351 Supplying of Funnel Stand as per Department Incharge 352 Supplying of Fusion Tubeas per Department Incharge 353 Supplying of Glass Rod as per Department Incharge 354 Supplying of Glass Tube as per Department Incharge 355 Supplying of Stopwatch Steel body as per Department Incharge 356 Supplying of Magnetic Stirrer as per Department Incharge 357 Supplying of Rubber Gloves as per Department Incharge 358 Supplying of Reagent as per Department Incharge 359 Supplying of Sandbath as per Department Incharge 360 Supplying of Tissue Paper(Local made) as per Department Incharge 361 Supplying of Double Beam PC Microprocessor UV-VIS Spectrophotomet erMake:Systroni cs Model: 2202 PC Based Double Beam Automatic source optimization ,Base line calibration & Cell optimization 200 - 1100 nm Range2. 0 nm Bandwidth%T. Abs. Conc . (K factor. Multi standard ). Multi component measuring modesSingle Wave length, Multi Wave length Scan (with multi scan facility). Time Scan. Kinetic scan operating modes Automatic 5 position sample changer Single Position 50 /100 mm Cuvette Holder (Optional) as per Department incharge 362 Supplying of Refrigerated Centrifuge,(Specification:Speed:- 20000 Max.,RCF:- 37570 Max.,Lowest Temp:- -8,Noise:- <-60db)as per Department incharge 363 Supplying of Refrigerated Centrifuge Essential accessories Required:. With angle Heads (with polypropylene tubes)Model- R-248M 24xl.5 ml as per Department incharge 364 Supplying of Refrigerated Centrifuge 2. Voltage stabilizer:- 03 KW Servo controlled Voltage Stabilizer, input 170 volts to 260 volts, output 220 volts to 240volts as per Department incharge 365 Supplying of PCR machine(Specification- Well block, Gradient, temp. range 4° - 99-irC, memory capacity 10000 protocols , display 7inch,volume capacity I 0- 100 μL , preloaded protocol, temperature accuracy ±0.2°C@99°C, with PCR wizard as per Department incharge 366 Supplying of SOS PAGE unit and Western Blot apparatus along with power bank -Mini-TBC electroph_oretic transfer cell, includes: Mini 01P-4 cell tank and lid with cables, buffer, Mini transfer module, gel holder cassettes, 4 fiber pads, cooling units, instructions, Western blot unit, compatible power bank as per Department incharge 367 Supplying of pH Meter With electrode(Type of PH Mater - Portable,Ph Range:0-14,Resolution-0.01pH,compensation-0 to 80 degree celsius) as per Department incharge 368 Supplying of Deep fridge(It is used to store chemicals and preserve samples at very low sub-zero temperatures or below)as per Department incharge 369 Supplying of Autoclave (Vertical)Size- 400 x 600mm ,;Capacity- 75Ltr as per Department incharge 370 Supplying of Hot air oven (Sterilization) as per Department incharge 371 Supplying of Incubator Shaker-Growth and enumeration of microbes (Broth cultures) as per Department incharge 372 Supplying of Horizontal Laminar air flow(Sterile environment Size 4X2)as per Department incharge 373 Supplying of Horizontal Agarose gel electrophoresis unit with gel caster and Power pack Separation of macromoleculeas per Department incharge 374 Supplying of Vortex mixture-To mix content of test tubes and microfuge tubes. as per Department incharge 375 Supplying of Ultrapure Water Purification System:MiliQ Water For distill wateras per Department incharge 376 Supplying of Micropipets - 0.1μL-2.5μL 0.5μL-10.0μL 10.0μL-l00μL 20.0μL-200μL l00μL-l000μL as per Department incharge 377 Supplying of Quebec Colony Counter -Count the microbial colonies as per Department incharge 378 Supplying of Light Microscope (General) 10X,20x, 45x, l00x Visualize microorganisms as per Department incharge 379 Supplying of Bifocal microscope with illuminators, Camera attachment and computer Visualize microorganisms and microgrphy as per Department incharge 380 Supplying of Magnetic stirwith Hotplate and magnetic beads To stir the liquids , preparation of solution as per Department incharge 381 Supplying of Heating mantle For heating round bottomed flask/distillation flask as per Department incharge 382 Supplying of Microwave oven To heat liquids instead of flaming. Samsung/ LG 20 Ltrs as per Department incharge 383 Supplying of Glass Dessicators Used for dessication as per Department incharge 384 Supplying of Fluorescence microscope A fluorescence microscope is an optical Microscope that uses fluorescence and phosphore scence instead of,or in addition to, reflection and absorption to study properties of organic or inorganic substances as per Department incharge 385 Supplying of Electronic Analytical Balance It is used to weigh small quantities of chemicals and samples precisely and quickly. Readability- 1 mg (0.001 g) Cap.- 420gm as per Department incharge 386 Supplying of Electronic Top pan Balance- Readability- 0.1 g Cap.- 2 kg.as per Department incharge 387 Supplying of Double Distillation Unit ,.Approx output: 2 Lit/hrs Wattage:3.3 .KW With safety Cutoff Device Water Stills are carefully designed to produce high purity pyrogen free distiiied water. The water still comprises ofborosilicates glass horizontal typeboiler, coil condenser, constant level device, silica sheathed heaters, along with stand and clamps. All parts are replaceable. pH/conductivity:6-7 / 1-2 μSiem forsingle, 6-7/0.8-lμS/cm for double distilled water as per department incharge 388 Supplying of Microtome-5286(Product Specification Minimum Setting Value-0.5 um,Object Feed-28 mm,Vertical Stroke-60 mm,Specimen Orientation X and Y Axis Universal 8 Degree Trimming Thickness Range-1 um-100 um Operation-Automatic. (Motorized Feed & sectioning and Emergency Stop Provided),Sectioning Speed-0-400 mm/sec.,Specimen-Orientation Z Axis-Upto 360 Degree,Retraction Value-Adjustable Max Specimen Size-50 x 50 mm,Section Thickness Range-0.5 um-60 um)Senior rotary microtome as per Department incharge 389 Supplying of Cryostat -(Product Specification Section Thickness Range-0.5 Micron to 100 Micron (with the increment of 0.5 Micron, 1 Micron, 2 Micron, 5 Micron) Power Supply-220v,Dimension-750mm x 750mm x 950mm (approx) Weight -123 kg (approx),Remote Control-Optional,Sectioning Mode-Single step mode/ Continuous mode Hand Wheel Control-Feather Touch Keypad/ Foot Switch/ Remote Control (optional),Sterilization-U.V-C Sterilization,Cooling down time Up to -30 DegreeC-2 Hour 30 Min Specimen Retraction setting Range-5 Micron to 100 Micron (with increment of 5 Micron),Compressor-Dual Compressor,Cryo Chamber Temp. Adjustable -1 DegreeC to -30 DegreeC Block Holder Head Temperature-Adjustable -1 DegreeC to -35 DegreeC Illumination-LED Lamp)Ultimate usico fully automatic cryostat as per Department incharge 390 Supplying of ELISA -Vet scientific(Specification-Product Specification Automation-Semi Automatic,Assays Performed-ELISAs, Immuno Assays Plate Format-96 well,Optical System Filter-based Detection Method-Absorbance,Number Of User Programs 42 Storage-100000 Results,Filter Positions-8 Display Type-Touch Screen Packaging Type-EXPORT QUALITY,Testing Speed-3 second Type Of Filter 405,450,492, 630,Power Source-115/230 V AC, 50Hz,Weight-9 Kg,Is It Portable-Non Portable, sample Type-Serum, Plasma, Urine, CSF, Whole Blood,sample Volume Range-10-100 Interface-RS232/ USB) as per Department incharge 391 Supplying of Calorimeter -A VI Digital (A VI Scientific,Frequrcy:50Hz,Voltage:230-280V,operating time per test-10 min) as per Department incharge 392 Supplying of HaemometerSahli type-Microsidd (Specification:Amber coloured glass bottle -1 No.,Glass Stirrer-1 No.,Dropper with teat -1 No.,Cleaning Brush -1 No.,Spare latex tubing one meter -1 No.Round tube haemoglobinometer) as per Department incharge 393 Supplying of Anti - theft Sticker with the University logo as per Department incharge 394 Supplying of Middleware Application Desktop(Write and Read Tags) as per Department incharge 395 Supplying of RFID Staff Station or desktop reader (Used for tagging of books and circulation {lssue/Return) operations through RFID) as per Department incharge 396 Supplying of Integration with Software and Training of Complete RFID System as per Department incharge 397 Supplying of RFIDSecurityGates (2 pedestals-1 gate) RFID Security Gate (Single Lane) as per Department incharge 398 Supplying of Automated Book drop Box as per Department incharge 399 Supplying ofCabling. Casing. Wiring , Switches as per Department incharge 400 Supplying of Freight Transportation of Miidle ware Application Desktop,RFID STAFF Station,Integration with software training,Automated Drop box ,Cabling,Casing,Wiring,Switches as per Department incharge 401 Supplying of LAN . Switches, Necessary Cabling, Casing , Power Supply port including cables as per Department incharge 402 Supplying of Dedicated serverGHZ 16 core 1P-32GB -RP408ia -NC8SFF800WPS Serverintel Xeon -G5218 Kit for DL 380 GEN-10-HPE 32GB 2RX4 PC-4 2933YR Smart kit ,HPE DL38x Gen 10-12 Gb SAS Expande,HPE DL 380Gen 10 Box 1/2 Cage Bkpin kit ,HPE 24TB SAS 12G 10K SFF SC 512eDS HDD .HPE 800 WFS Ht Plg LHPwr Sply kit,HPE 3 Year Fiundation care 24x7 DL 380 Gen 10 Serviceas per Department incharge 403 Supplying of RS 86+_TB619RS, 3GB RAM and 48 GB ROM,4K Display Android model,3 GB RAM And 48 GB ROM,slim frame,Anti Glare Glass,3M Anti glare H7 Anti touch surface hardness lightweight for easy installation,Media suits for Annotation,Software bundled with education apps,Office suits,Great writing experience,Object recognition -First pal,/Fine pen ,Touch Points-20 points under window and 10 points under android,178 degree viewing angle IR ,Touch 15000,1 contrast ratio,4 MS Response time 50000 hours life,Reduce clutter and bring efficiency for the faculty,Remote control,15 wattX2 speaker,Android 8.0,Newline cast,Display management,Newline broadcast including installation and Trainingas per Department incharge 404 Supplying of Deep Fridgeas(2 in 1 Converti Freezer & Cooler Corrosion Resistant Cooling Coil & PPGI for inner & outer body Heavy Duty Compressor & Tropicalised Design Approximately 14% Higher Net Capacity compared to competition Sleek Design with heavy duty performance) per Department Incharge 405 Supplying of Autoclave (Horizontal,Height X Dia: 450mm x 250mm Height x Dia: 18Inch x 10Inch,Capacity: 22 Ltr,Load: 2.0 KW) as per Department Incharge 406 Supplying of Autoclave (Vertical): size- 400x600mm, Capacity- 75Ltr as per Department Incharge 407 Supplying of Hot air oven(Standard double wall fabrication. Inner chamber made of highly polished stainless steel sheet. Exterior fabricated out of thick mild steel sheet duly finished in stove enamel off-white paint or paste mat finish colour combinations.Nichrome wire heating elements -provided on three sides attain quick and uniform heating in range of 50c to 250c + 1c controlled by capillary type thermostat.Inner Chamber Size 18x18x18 inch. made of Stainless Steel) : any Standard make as per Department Incharge 408 Supplying of Bacteriological incubator(Item Weight ‎10 kg Product Dimensions-30 x 30 x 30 cm; 10 Kilograms,Item model number-12X12,Item Height-30 Centimeters Item Width-30 Centimeters) as per Department Incharge 409 Supplying of Bacteriological shaking incubator as per Department Incharge 410 Supplying of BOD incubator as per Department Incharge 411 Supplying of Laminar air flow any Standard company as per Department Incharge 412 Supplying of Micropipettes with microtips :(1.0uL-10.0uL, 10.0uL-100uL, 100uL-1000uL, 20uL-200uL): A. Prime Variable Pipette, B. Fully Autoclaveable Variable Vol. Pipetteas per Department Incharge 413 Supplying of Colorimeters with cuvettes any Standard company as per Department Incharge 414 Supplying of Western Blot apparatus, as per Department Incharge 415 Supplying of Powerpack with wiresas per Department Incharge 416 Supplying of Homogeniser as per Department Incharge 417 Supplying of PCR machine Block Formats 96x0.2ml(A),54x0.5ml(B), 96x0.2ml +77x05ml©, 384well(D) Size(WxDxH,mm)-380x270x250 as per Department Incharge 418 Supplying of UV Transilluminator/UV chamber UV source: 365nm Wave Length Viewing area: 24x14cm Anti Slip rubber foot provided for base as per Department Incharge 419 Supplying of CO2 incubator as per Department Incharge 420 Supplying of pH meter and buffers: A.pH meter B. pH buffers as per Department Incharge 421 Supplying of Water bath (any Standard company ) as per Department Incharge 422 Supplying of Fume Hood: size- 3x3x2 wooden with Granite working area as per Department Incharge 423 Supplying of Soxlet apparatus with heating mantle and distillation set up as per Department Incharge 424 Supplying of Kjeldahl Apparatus as per Department Incharge 425 Supplying of Ultrapure Water Purification System: MiliQ water as per Department Incharge 426 Supplying of Quebee Colony Counter as per Department Incharge 427 Supplying of Light Microscope (general) 25x, 45x, 100x s as per Department Incharge 428 Supplying of Bifocal microscope with illuminators as per Department Incharge 429 Supplying of Magnetic stirrer with magnetic beads(any Standard company )as per Department Incharge 430 Supplying of Magnetic stirrer with hot plate (Remi) as per Department Incharge 431 Supplying of Heating mantleas per Department Incharge 432 Supplying of Microwave oven ((20Ltr) as per Department Incharge 433 Supplying of Glass Dessicators as per Department Incharge 434 Supplying of Computer : Core i9, 7th Gen. 20 LED Monitor, 4GB DDV, 1TB HDD, DV writer HP/Dell as per Department Incharge 435 Supplying of Culture room: Tissue culture Rack fitted with 16 tubes, 8 bulbs, 4UV & Timer as per Department Incharge 436 Supplying of Electronic Analytical Balance:- Readability- 1mg(0.001g) Cap.-420gm as per Department Incharge 437 Supplying of ElectronicTop-pan Balance:-Readability- 0.1g Cap- 2kgas per Department Incharge 438 Supplying of Electroporator:- as per Department Incharge 439 Supplying of Fermenter(7.5L)(any Standard company )as per Department Incharge 440 Supplying of Fluorescence Microscopeas per Department Incharge 441 Supplying of Hot air oven universalas per Department Incharge 442 Supplying of Distillation Unit as per Department Incharge 443 Supplying of Membrane filter assembly 5000 mlas per Department Incharge 444 Supplying of Fluorimeter as per Department Incharge 445 Supplying of Homogeniser: Remi model- RQT-127 A/D High speed homogenizer, with 1/8 HP Motor, Homogenizer Working Volume [H2O] 0.1-50ml (Dispersing shaft DS-160/5) WEIGHT 0.6KG Dimension[LxWxH] 46mmx55mmx230 operating environment 0-40degre, 85% rel. humidity as per Department Incharge 446 Supplying of ELISA reader and Microtitre plates: ELISA Wavelength range 400nm-800nm Accuracy- +-1% at 1.0OD, 450nm Dimension 450x350x197mm as per Department Incharge 447 Supplying of Liminar air flow : 4x2x2 feet, stainless steel as per Department Incharge 448 Supplying of Gel Documentationd system as per Department Incharge 449 Supplying of 5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 450 Supplying of 12V/26AH- Batteryas per Department Incharge 451 Supplying of Headphone with built in microphone (Brand) as per Department Incharge 452 Supplying of Furniture:- Computer Table & Chairs & Table- Chair for lab. Instructor and student (50 students per batch) as per Department Incharge 453 Supplying of Network:- LAN, Switches, Cabling, Casing Power Supply Port including Cables as per Department Incharge 454 Supplying of 5.5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 455 Supplying of RS86+ TT8619RS 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0, Newline Cast, Display Managemen, Newline Broadcast Including Installation and Training. as per Department Incharge 456 Supplying ofpH meter(Digital) :- pH range: 0-14, Temperature Range: 0.0 to 100 C (Manual Compensation) as per Department Incharge 457 Supplying ofNoise Level meter:- Auto/Manual ranging from 30 to 130dB in 6 ranges as per Department Incharge 458 Supplying ofWater analysis Kit:- They include; alkalinity, chloride, hardness, iron, and sulphate as per Department Incharge 459 Supplying ofHigh volume sampler:- 1)PM-2.5- Designed to meet International Standards for High volume air Sampling of PM2.5 particulates. 2)PM-10-U.S EPA FRM Designed for the determination of suspended of PM-10 particulates concentrations. (RFPS-1287-063) 3)TSP- Designed to meet U.S EPA reference method for determination of total suspended particulates(TSP) concentration as perDepartment Incharge 460 Supplying ofSoil testing kit (mrinda parikshan kit) : Use for micro and macro nutrients as per Department Incharge 461 Supplying ofSeive plate with shaker : 5mm,1mm,2mm) as per Department Incharge 462 Supplying ofUV/Visible spectrophotometer:- Spectral bandwidth 1 nm (190 to1100nm , Lamp Type 20-W halogen lamp and deuterium lamp as per Department Incharge 463 Supplying ofAutoclave : 10-15 litre Steam Sterilizer as per Department Incharge 464 Supplying ofLaminar hood (Horizantal) : Horizontal air flow cabinet, filter air blow across the work zone in horizontal direction. This constant flow of air provides material and product protection as per Department Incharge 465 Supplying ofHot plate(pic):-Temperature range: 350 C as per Department Incharge 466 Supplying ofShakeer incubator Compact Bench top shaker with temperature control range from Ambient +50C to 600C. Tray dimension : 420x420 , Speed 50-350 rpm with accuracy of +/- 2rpm as per Department Incharge 467 Supplying ofMuffle Furnaces (15x125x250)cm: Temperature upto 35C to 1400C as per Department Incharge 468 Supplying of Analytical Balances:Capacity 220gram as per Department Incharge 469 Supplying ofDigester : 1) vessel size : Dia 39 mm (Aprox.); Volume 160ml 2)Temperature : upto 200degC as per Department Incharge 470 Supplying ofDouble distilled water plant: Model- Vertical:- Distlled Water Output Capacity-2.5 Litres/Hours, Distillate water quality as per Department Incharge 471 Supplying ofOven:- Dry ovens- 30 to 1000 litre capacity. as per Department Incharge 472 Supplying of B.O.D Incubator: Volume 68 Litre as per Department Incharge 473 Supplying ofMagnus Microscope:- Magnification 4x,10x,40x, and 100x as per Department Incharge 474 Supplying ofDesiccators:- Contain: Silica Gel dimension;12x12 in (30.5x30.5 cm),Material Glass as per Department Incharge 475 Supplying ofRichter scale hardness tester Portable Rockwell/brinell vickers Hardness Testing Instrument Mold metal hardness meter display:-parameter- HRC Display Type, Digital Model Name/Number- ATedigiHR, Accuracy- 0.1 HRC Dimensions of Machine base (approx.) 150x425 mm as per Department Incharge 476 Supplying ofProctor Penetrometer: Proctor Penetrometer- Complete with set of needle points Weight, 2 kg as per Department Incharge 477 Supplying ofGas Chromatography Retention time repeatability-< 0.008% or 0.0008 min Area rpeatability -<1% RSD, using 2ng tetradecane as per Department Incharge 478 Supplying of Atomic Absorption Spectrometry(AAS):- aa-7000 SERIES OF Atomic Absorption Spectrophotometers features high- sensitivity analysis as per Department Incharge 479 Supplying ofWavelength range; 400 to710nm Wavelength selection: 8 in-built gelatin filters: 430,470,490,520,540,580,600 and 710 nm Measurement ranges; 0-100%T, 0-1.50Abs, 0.1 to 1000 Concentration. Resolution: 1%T, 0.01Abs, 0.1 to 1 Concentration as per Department Incharge 480 Supplying of Laptops(of Specification:Processor Corei5,RAM:4GB,Hard drive:500GB ,Screen size:12 inch):as per Department Incharge 481 Supplying of Desktops: i7 3rd Gen, 1TB HDD, 4GB RAM, Windos 10, MS office, Graphics card as per Department Incharge 482 Supplying of Xerox Machine(Product Specification:Functions Multi-Function:Supported Paper Size-A3,Supported OS-all,Color Output-Black & White,Number Of Trays-4,Item Color-white and blue Print Speed-up to 35 ppm,Weight 129 kg,Print Technology-Laser Warm-Up Time, As fast as 11 seconds (black and white) Duty Cycle-WorkCentre 5335: Up to 150,000 pages / month Resolution-200 x 1200 dpi) as per Department Incharge 483 Supplying of Air Conditioning:-1.5 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 484 Supplying of Luminous Cruze 3.5KVA Inverter with RC 18000 Battery (4 Batteries) as per Department Incharge 485 Supplying of Projector(Special Feature-portable,Connectivity Technology,Bluetooth, Wi-Fi, USB, HDMI,Display resolution 1920 x 1080,Display Type-LED) as per Department Incharge 486 Supplying of Godrej Lecture Hall Furniture as per Department Incharge 487 Supplying of Electronic Podium(Speaker type-Tweeter,Auxillary,wireless,floor standing) as per Department Incharge 488 Supplying of Smart board (Screen size-11 inches,Connecting technology-Wifi,Multimedia)as per Department Incharge 489 Supplying of Black board( Melamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS CornersMelamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS Corners) as per Department Incharge 490 Supplying of Glassware rack as per Department Incharge 491 Supplying of installation of Air conditioner,Luminous Cruze,Projector,Lecture Hall Furniture,Electronic podium,Smart board and black board as per Department Incharge 492 Supplying of Inductively coupled Plasma - Optical Emission Spectrometer with CID detector technology for multi-element analysis of geological petrogical etc. samples in ppb level as per Department Incharge 493 Supplying of Suppressed ion analysis system for anion and cation analysis in water, wastewater, environmental samples and also upgradable to combustion for determination of corrosive halogens and sulfur in Petrochemicals, gaseous samples, solid samples, and complex samples as per Department Incharge 494 Supplying of CHNS/O for the analysis of Carbon, Hydrogen, Nitrogen, Sulfur and Carbon in organic matrices, soil, feed , plant samples, petroleum products, Coal, Coke, Biomass & Liquid Fuels as per Department Incharge 495 Supplying of Gas Analyzers for hydrocarbon and permanent gas analysis as per Department Incharge 496 Supplying of Benchotop XRD as per Department Incharge 497 Supplying of XRF Spectrometer as per Department Incharge 498 Supplying of Refrigereted Centifuge MakE-REMI, Model-C24 PLUS :- Max. Speed:20000, Max. RCF:3757, Max. Lowest Temp.:8, Noise:60db. Essential accessories Required: 01. Withangle Heads (with polypropulene tubes) Model-R-248M24x1.5ml 2)Voltage stabilizer:-03KW Servocontrolled Voltage Stabilizer, input 170volts to 260volts, output 220 to 240volts as per Department Incharge 499 Supplying of pH Meter compatible poer bank Make: REMI :- With eletrode as per Department Incharge 500 Supplying of Bench top Centrifuge Make: Tarson, : - SPINWIN MC-001 6 places Rotor for 1.5 ml tubeas per Department Incharge 501 Supplying of Deep Fridge: It is used to store chemicals and preserve samples at very low sub-zero tempertures or below as per Department Incharge 502 Supplying of Autoclave(Vertical) : size- 400x600mm capacity- 75Ltr as per Department Incharge 503 Supplying of Hot air oven : Sterilization as per Department Incharge 504 Supplying of Incubator Shaker: Growth and enumeration of microbes(Broth Cultures) as per Department Incharge 505 Supplying of Horizontal Laminar air flow:- Sterile environment size 4x2as per Department Incharge 506 Supplying of Ultrapure Water Purification System: MiliQ Water : for distil water as per Department Incharge 507 Supplying of Micropipets (Ependroff): 0.1uL-2.5uL, 0.5uL-10uL, 10.0uL-100uL, 100uL-1000uL each oo these 1pcs as per Department Incharge 508 Supplying of Light Microscope (general)10X, 20X, 45X, 100X, : Visualize microorganisms as per Department Incharge 509 Supplying of Bifocalcal Microscope with illuminators, Camera Attachment and comput: Visuallize microorganisms and micrography as per Department Incharge 510 Supplying of Magnetic stir with Hotplate and magnetic bead as per Department Incharge 511 Supplying of Heatingmant; for heatinground bottomed flask/distillation flask as per Department Incharge 512 Supplying of Microwave oven: To heat liquids instead of flaming. 20Ltrs as per Department Incharge 513 Supplying of kydroPro 100 handeld multiparameter water quality analiser: Turbedityas per Department Incharge 514 Supplying of Petrological Microscope: Study of Optical minrology as per Department Incharge 515 Supplying of Ore petrological microscope: Study of ore petrology as per Department Incharge 516 Supplying of Miscellaneous instruments as per Department Incharge 517 Supplying of glassware as per Department Incharge 518 Supplying of chemical as per Department Incharge 519 Supplying of Arc GIS(Latest) as per Department Incharge 520 Supplying of GCD Toolkits as per Department Incharge 521 Supplying of SURPAC Software as per Department Incharge 522 Supplying of Intergraph Edu Kit [GIS+RS] Version 2020 or latest(Software content as per list), 5 users for Erdas imagine Professional and 5 users for Geomedia professional Software as per Department Incharge 523 Supplying of Interactive Flat Panel as per Department Incharge 524 Supplying of 2 Virtual Class Room including capture, recording and streaming online, 1 Servers one per 05 classrooms per Department Incharge 525 Supplying of N-computing for smart classrooms including servers and clients as per Department Incharge 526 Supplying of Tagging of documents(books/hard-bound journals/CDs/technical films etc)in RFID Technology as per Department Incharge 527 Supplying of Sofwares, Server Machines, Air-Conditioning Systems,Xerox Machines, Lamination Machines, Binding Machines, Furniture/Furnishing, Computers, Printers etc as per Department Incharge 528 Supplying of Digital Podium, PTGN 500, Window & 1 LCD, Elecronic Lectern, on site OEM. Warranty 3years, 3GB RAM,4GB ROM as per Department Incharge 529 Supplying of Air Conditioning:-1.8 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 530 Supplying of Black/ White,Printer:- scan-copy all in printer- Branded as per Department Incharge 531 Supplying of CCTV set for floor: 55 LRD display for CCTV. CCTV Camera-1 P based CCTV camera 2TB space with NVR with necessary accessories as per Department Incharge 532 Supplying of 5KVA Inverter online UPS with battery backup 100Mah battery(8 units) as per Department Incharge 533 Supplying of Electrophoresis Apparatus as per Department Incharge 534 Supplying of Bacteriological Incubator as per Department Incharge 535 Supplying of Autoclave as per Department Incharge 536 Supplying of Centrifuge as per Department Incharge 537 Supplying of Rotar Head as per Department Incharge 538 Supplying of Rotar Head 25 as per Department Incharge 539 Supplying of Gel documentation system as per Department Incharge 540 Supplying of Spectrophotometers as per Department Incharge 541 Supplying of compoud Microscope as per Department Incharge 542 Supplying of Trinocular Microscope with camera as per Department Incharge 543 Supplying of Semi-Automated Microtonne as per Department Incharge 544 Supplying of DNA Sequencer as per Department Incharge 545 Supplying of Spectrophotometer as per Department Incharge 546 Supplying of Laminar air flow chamber as per Department Incharge 547 Supplying of Tissue culture rack as per Department Incharge 548 Supplying of PCR Apparatus as per Department Incharge 549 Supplying of Liquid nitrogen cylinder as per Department Incharge 550 Supplying of TLC apparatus kit as per Department Incharge 551 Supplying of TLC Visualizer/documentation as per Department Incharge 552 Supplying of HPLC System as per Department Incharge 553 Supplying of Scientific vortex mixer as per Department Incharge 554 Supplying of Soil Thermometer as per Department Incharge 555 Supplying of Scientific Digital Balance as per Department Incharge 556 Supplying Equipments for workshop,Seminar & Excrusion as per Department Incharge 557 Supplying Equipments for Non-Recurring(Research Equipment) as per Department Incharge 558 Supplying Equipments for Recurring(Chemical & Glassware) as per Department Incharge 559 Supplying of Furniture Bookshelves, Study Tables and Chairs for Readers as per Department Incharge 560 Supplying of Desktop i5 Processor, 7th Generations, 500GB HDD, 4GB RAM, 23.8 inch, LED backlit Monitor Full HD IPS Panel (Brand: HP/DELL) as per Department Incharge 561 Supplying of Headphone with built in microphoneas per Department Incharge 562 Supplying of Printer with scanner (Laser,Colour/B/W)as per Department Incharge 563 Supplying of Scanner(USB,25.2D x 36.8W x 4.3H Centimeters,Slide) as per Department Incharge 564 Supplying of Xerox Machine:- (,Platen cover & Toner, Resolution (DPI):1200 X 1200dpi, Duty Cycle:1.3 Sec) as per Department Incharge 565 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-500mm,Laminating speed-1200mm)as per Department Incharge 566 Supplying of CCTV Camera(Full HD Picture,AI Powered Motion Detection,Infrared Night Vision; 360° Panorama,Talk Back Feature (2-Way Audio)Material Type: Plastic; Included Components: Camera, Power Adapter, Charging Cable, Wall Mounting Kit, User Manual; Specific Uses For Product: Surveillance) as per Department Incharge 567 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 568 Supplying of RS75+ TT7519RS RS 75+ comes with 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management. as per Department Incharge 569 Supplying of Wall Mount Kit(Material: SS,Max loading capacity-60 to 100kg) as per Department Incharge 570 Supplying of Live streaming software Software Software for Live Streaming or Live telecast as per Department Incharge 571 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 572 Supplying of Frieght Transportation of 4K Display,Wall mount kit,Live Streaming software as per Department Incharge 573 Supplying of cctv solutions for Department with 20 cameras(Image Sensor Type-CMOS,Image Sensor Size-0.357 inch,Camera Image Sensing capacity (Picture Mode)-2MP,Resolution-Full HD (1920 x 1080 Pixel)-Day/Night Capable-Yes,IR illumination Range(mtr) 200 Type of Camera HousingDOME CAMERA,IP Camera Yes) as per Department Incharge 574 Supplying of installation and commisioning of CCTV and other computer equipment as per Department Incharge 575 Supplying of 55 Tv for seeing all cctv in HOD room as per Department Incharge 576 Supplying of8 PORT EPBX as per Department Incharge 577 Supplying ofTELEPHONE as per Department Incharge 578 Supplying ofWIRE as per Department Incharge 579 Supplying of CRON BOX as per Department Incharge 580 Supplying ofSWITCHES FOR PORTS as per Department Incharge 581 Supplying of Workststion Table, Chairs, Desktop, UPS as per Department Incharge 582 Supplying of LAN, Switches, Necessary Cabling, Casing Power Supply Port including Cables as per Department Incharge 583 Supplying of Refrigerator(Storage & Interior Description : | Cooling Type ; Frost Free | Display Type ; Thermostat | Shelf Material ; Toughened Glass | Compressor Type ; Reciprocatory)as per Department Incharge 584 Supplying of Microwave(Special Features: Quartz Heater - Concealed Heating. Safer Cooking, Stainless Steel Cavity - More Hygienic. More Durable, Child Lock - Ensures complete safety especially for homes with young children, Interior light)as per Department Incharge 585 Supplying of Washing Machine( Fully automatic 6 kg) as per Department Incharge 586 Supplying of Sewing Machine(Motorised)as per Department Incharge 587 Supplying of Weighting Machineas per Department Incharge 588 Supplying of Blood Pressure Monitor as per Department Incharge 589 Supplying of Oximeter as per Department Incharge 590 Supplying of Gluco Meter as per Department Incharge 591 Supplying of Test Tube & Breakers as per Department Incharge 592 Supplying of RO Water Purifier as per Department Incharge 593 Supplying of Microscope(Student) as per Department Incharge 594 Supplying of Crockery Set as per Department Incharge 595 Supplying of Cocking Utensils set as per Department Incharge 596 Supplying of Cutlery Set as per Department Incharge 597 Supplying of Sofa Set + Centre Table as per Department Incharge 598 Supplying of A.C (Split 2 Ton,3 Star,Twin invertor HD Compressor)as per Department Incharge 599 Supplying of Stabilizer(Automatic Voltage Stabilizer,37.4 x 27.1 x 19.8 Centimeters,5 kg 700 g)as per Department Incharge 600 Supplying of Inveter with battery(Capacity -100AH,Battery Type-Tubular Battery,Warranty-1 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 1 FAN ,28 Light , 8 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 601 Supplying of Desktop Computer with UPS and Computer Tableas per Department Incharge 602 Supplying of Original operating system software window 10 with Antivirus as per Department Incharge 603 Supplying of Printer with scanner (inkjet,Colour/B/W)as per Department Incharge 604 Supplying of Dining Table Set as per Department Incharge 605 Supplying of Camera as per Department Incharge 606 Supplying of Mixer Grinder as per Department Incharge 607 Supplying of Iron as per Department Incharge 608 Supplying of Wall Clockas per Department Incharge 609 Supplying of Whole tailoring Equipments (Local) as per Department Incharge 610 Supplying of Knitting Equipments(Local) as per Department Incharge 611 Supplying of Flower Arrangement Equipments) (local) as per Department Incharge 612 Supplying of Aluminium Set as per Department Incharge 613 Supplying of Plastic Tub as per Department Incharge 614 Supplying of Dustbin(Big) as per Department Incharge 615 Supplying of Basket &Mug as per Department Incharge 616 Supplying of White Table Cloth(Big size)as per Department Incharge 617 Supplying of Wash Basin(Local)as per Department Incharge 618 Supplying of Gas Stove +Cylinderas per Department Incharge 619 Supplying of Curtains(Local) as per Department Incharge 620 Supplying of Floor Mats (Local) as per Department Incharge 621 Supplying of Tube Lightas per Department Incharge 622 Supplying of Fan as per Department Incharge 623 Supplying of Led Projector(New Edition)as per Department Incharge 624 Supplying of Smart Board(specification:white,power consumption<150w ,usage-school,Effective touch-65x46) as per Department Incharge 625 Supplying of Decorative Items(Local) as per Department Incharge 626 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 60 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 15000 ppm,Features-Two-sided printing,Weight-25kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scanner multi as per Department Incharge 627 Supplying of Ceiling Fanas per Department Incharge 628 Supplying of Exhaust Fan as per Department Incharge 629 Supplying of Pedestal Fan as per Department Incharge 630 Supplying of Inveter with battery(Capacity -200AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 14 Hrs Backup- 4 FAN , 8 Light , 14 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 631 Supplying of Wooden Stool(Local) as per Department Incharge 632 Supplying of Wash Basin (Local) as per Department Incharge 633 Supplying of Register (Local) as per Department Incharge 634 Supplying of Stabilizer for ACas per Department Incharge 635 Supplying of Tubelightas per Department Incharge 636 Supplying of Dustbin (Local) as per Department Incharge 637 Supplying of Curtains (Window and Door) (Local)as per Department Incharge 638 Supplying of Door Mat(Local) as per Department Incharge 639 Supplying of Broadband(Wifi)as per Department Incharge 640 Supplying of Furniture Bookshelves, Study Tables and Chairs for attendant and students (30 students at a time) as per Department Incharge 641 Supplying of Wireless mic as per Department Incharge 642 Supplying of Weight Box(100g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 643 Supplying of Weight Box(50g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 644 Supplying of Kymograph :-with smoked paper, smoked Drum, Time marker as per Department Incharge 645 Supplying of Memory Drum :- Electrical operated as per Department Incharge 646 Supplying of Memory Drum :- Hand operated as per Department Incharge 647 Supplying of Metronome :- Mechanical as per Department Incharge 648 Supplying of Porteuz Maze Test as per Department Incharge 649 Supplying of Techisto-scope :- Fall Drop type as per Department Incharge 650 Supplying of Techisto-scope :-Electronic as per Department Incharge 651 Supplying of Verniers chronoscope :- Pendulum Type as per Department Incharge 652 Supplying of Ergograph/Smoke drum /smoke paper varshing tray and varnish :- Hand grip model as per Department Incharge 653 Supplying of Weight 6Kg as per Department Incharge 654 Supplying of Multiplication sheets(100sheet) as per Department Incharge 655 Supplying of Screen:- Wooden as per Department Incharge 656 Supplying of Ravens Progressive Matrices as per Department Incharge 657 Supplying of Weschlers Intelligence scale (Adult) as per Department Incharge 658 Supplying of Cattles 16 PF Questionnaire as per Department Incharge 659 Supplying of Jungs Word Association Test as per Department Incharge 660 Supplying of Thematics Apperception Test as per Department Incharge 661 Supplying of Zeigarnik Effect Test as per Department Incharge 662 Supplying of The Occupational Stress Index(OSI) Scale by A.K Shrivastawa and A.P. Singh as per Department Incharge 663 Supplying of Rorschach Test as per Department Incharge 664 Supplying of Coping Strategies Test by A.K. Shrivastava as per Department Incharge 665 Supplying of Job Satisfaction scale(JSS) by Amar Singh and T.R. Sharma as per Department Incharge 666 Supplying of Job Involvement Scale by A.K. Singh and R. Kapoor as per Department Incharge. 667 Supplying ofOrganizational Climate Scale by Somnath Chatopadhya and K.G. Agarwal as per Department Incharge 668 Supplying of Managerial Aptitude Scale(MAS) by Santosh Dhar, Upinder Dhar and Priyanka Sharma as per Department Incharge 669 Supplying of Employees Motivational Scale by A.K. Shrivastava as per Department Incharge 670 Supplying of Employees Mental Health Inventory (EMHI) by Jagdish as per Department Incharge 671 Supplying of Beck Depression Inventory by Arron Beck as per Department Incharge 672 Supplying of Aggration Scale (AS) by G.P. Mathur and Rajkumar Bhatnagar as per Department Incharge 673 Supplying of Ego Strength Scale by Q. Hassan as per Department Incharge 674 Supplying of Bells Adjustment Iventory by S.M. Mohsin and Shamshad as per Department Incharge 675 Supplying of Marital Adjustment Questionnaire by P. Kumar and kanchan Rohtagi as per Department Incharge 676 Supplying of Sacks Sentence Completion Test as per Department Incharge 677 Supplying of PGI Health Questionnaire N-1 (PGIHQN) by S.K. Verma, N.N. Wig and D. Prasad as per Department Incharge 678 Supplying of Rotters Locus of Control Scal by Anand Kumar and S.N Srivastava as per Department Incharge 679 Supplying of Self Concept Inventory by O.N Srivastava as per Department Incharge 680 Supplying of PGI Social Support Scale by S.K. Verma, P. Kulhara and Ritu Nehraas per Department Incharge 681 Supplying of Emotiobnal Maturity Scale(EMS) by R.R. Trtipathi as per Department Incharge 682 Supplying of Life satisfaction Scale(LSS) by Q.G. Alam and R. Srivastava as per Department Incharge 683 Supplying of PGI Quality of Life Scale by S.K Verma and A.C. Moudgil as per Department Incharge 684 Supplying of Environmental Awareness Scale (EAS) by Haseen Taj as per Department Incharge 685 Supplying of Jatota Test of Group Mental ability as per Department Incharge 686 Supplying of Weinsteins Noise Sensitivy Scale (WNSS)(Shore Samvedi Mapak) by P. Bhatia, S. Mohar and I.S Mohar as per Department Incharge 687 Supplying of State Traight Anxiety Test (STAT) as per Department Incharge 688 Supplying of Xerox Machines (Digital)(Product Specification:Copy | Print | Scan | Fax,Number Of Trays-2,Item Color-Black,Duty Cycle-20000,Print Technology-LaserPrint Speed-25 Paper Per Minute ) as per Department Incharge 689 Supplying of Binding Machine (Product Specification:Capacity-12-15 Sheets,Binding Style-Manual ,Max Binding Thickness<20 mm Max Binding Sheet Width 200-300 mm,Automatic Grade-Semi-Automatic,Weight-5.8Kgs Approx.,Dimension-375x230x150mm Approx.Automation Grade,Hole Size-3x8mm,Paper Size-A4 /Letter /A5 etc,Packaging Weight-375 mm,Handle Type-metal,Packaging Size-375x230x150mm Approx.Adjustable Margin-2.5/4.5/6.5mm,Usage/Application-Comb Binding Method Of Operation-Manual,No Of Punch Holes-21 holes Number Of Punch Slots-21 holes,Size-A4,Number Of Punch Holes-21 holes,Machine Dimension-375x230x150mm Approx.Is It Padded)as per Department Incharge 690 Supplying of Printers(Ink End Sensor-yes,paper storage capacity-100 sheets Paper Input, 50 sheets Paper Output-printing technology ink tank,connecter type-Wi-Fi, USB,special feature-Cost per print - 9 paise (Black & White), 33 paise (Colour) as per Department Incharge 691 Supplying of Furnishing (Book shelves:Study table and chair)as per Department Incharge 692 Supplying of Book Case(for Psychological Tests) as per Department Incharge 693 Supplying of Open Racks as per Department Incharge 694 Supplying of Inveter with battery(Capacity -150AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 2 FAN , 2 Light , 12 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 695 Supplying of Inverter with Battery(Capacity-150,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit Backup Time-5hrs,Battery Condition-New)as per Department Incharge 696 Supplying of Desktop(Product Specification:Hard Drive Capacity-320GB,Operating System-Window,Screen Size-17 inch Processor-i5,Display Type LCD Processor) as per Department Incharge 697 Supplying of Tally sofware (Multi User) as per Department Incharge 698 Supplying of Barcode Machine(Product Specification:Type-Thermal Printers,Max Printing Size-10 IPS,Resolution (dpi)-203dpi Model/Type-Citizen CLS-700,Automatic Grade-Fully Automatic Print Line-1~3 Lines) as per Department Incharge 699 Supplying of Server Machines(Product Specification:Memory-1x16 GB RAM/ Open Bay- 2.5 Hot Swap SAS/ SATA,Power Supply 220 V,Networking Type-LAN,Number Of Ports/Channels-8 USB Port-Yes Processor Speed Intel Xeon Silver 4114 (Deca Core) 2.2GHz Power Consumption 750 W) as per Department Incharge 700 Supplying of LAN connection between 7 computers as per Department Incharge 701 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 30 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 10000 ppm,Features-Two-sided printing,Weight-16.8kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scannercannon image Class MF641CW multi as per Department Incharge 702 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-330mm,Laminating speed-600mm)as per Department Incharge 703 Supplying of Binding Machine (Punches-43 holes,Hole distance-43 holes in A 11 SHEET,Binding sizes:Max 11) as per Department Incharge 704 Supplying of Computers (Processor -AMD Ryzen 3,RAM-8GB,HDD-512 GB,screen size-19.5 inches,Operating system:Windows 11 )as per Department Incharge 705 Supplying of Office Computer (Processor:i5 10th,HDD:1 TB,RAM-4 GB,GT730 4GB Graphics) as per Department Incharge 706 Supplying oflaser printer(Product Specification:Color Output-Black & White,Function-Print | Scan | Copy,Max. Print Speed (Black)-18 ppm Max. Print Speed (Color)-17 ppm,Connectivity-Ethernet,Paper Size-A4,Print Volume-Up to 500 pages/month) as per Department Incharge 707 Supplying of Smart class Board(Power consumption:220-300V,size/Dimension-65,Input type-finger Touch) per Department Incharge 708 Supplying of Double battery(capacity-250Ah,Over current protection) Inverter(Back up time-5 hrs) as per Department Incharge 709 Supplying of Desktop Computers :- HP 23.8-inch FHD All in One Desktop with Alexa Built-in(10th Gen Intel Core i3- 1005G1/8GB/512 GB SSD/Windows 10/MS Office 2019/Natural Silver), 24-dp0816in as per Department Incharge 710 Supplying of Printer, ScannerMulti-Function Direct Wireless Network Laser Printer (Print, copy, scan, Black) as per Department Incharge 711 Supplying of Networking (LAN, leased lines, wi-fi, switches etc.) TP-Link Archer C6 Gigabit MU-MIMO Wireless Router, Dual Band 1200Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas and 1 Internal Antenna WiFi Coverage with Access as per Department Incharge 712 Supplying of Back up support(UPS, Generator, Transformer):-600VA UPS for Desktop/PC/Computers(not for Routers) with Automatic Voltage Regulation as per Department Incharge 713 Supplying of Xerox Machine:- (IR2004 With Duplex, Platen cover & Toner, Resolution (DPI):600 X 600dpi, Duty Cycle:4.3 Sec) as per Department Incharge 714 Supplying of IBM SPSS(Statistics Package Latest Version) as per Department Incharge 715 Supplying of Nvovo(Package) as per Department Incharge 716 Supplying of LCD Projector:- 1)Project movies,images or data from your devices,most effective in dark settings 2)Projector, Lens Cover/Stand, Carrying Pounch, USB Cable 3) Connect via Wi-Fi to Android smartphones and tables or connect HDMI to iPhone or iPad as per Department Incharge 717 Supplying of Projector Screen:- 1)10 Feet x 6 Feet, 133 Dia, 16:9 Format, UHD-3D-4K 2)Comes with FULL HD 1080P 3D and 4K Viewing Technology, Anti UV coating as per Department Incharge 718 Supplying of DTH connection:- 1)HD Set Top Box 2)Recording facility as per Department Incharge 719 Supplying of Television Set:- 1) Smart LED TV-42 inches 2)4K UHD (Resolution:3840x2160) 3)Connectivity-Input:3*HDMI,3*USB 4)Audio:20W output 5) 4K HDR provides exceptional clarity 6)Smartphone connectivity : Photo sharing plus, screen mirroring as per Department Incharge 720 Supplying of as per Desktop:- Intel i7, 8th Gen, 4GB N-Vidia Geforce Graphics card, 16 GB RAM, Monitor, CPU, Mouse, key board partment Incharge 721 Supplying of Multifunction Laser Printer,Scanner, and Copier :- Functionality: Print, Scan,Copy Print Technology : Monochrome Laser Connectivity: Hi-speed USB, Compatible with USB 2.0 Specifications4as per Department Incharge 722 Supplying of Speaker 7.1 surround stereo(Power -100W,Play tme-11 hours,Voice Range-9m) as per Department Incharge 723 Supplying of Digital SLR Camera: 1)EOS full HD movie mode with movie service 2)18 megapixel CMOS)APS-(sensor 3)14-bit A/D conversion 4)ISO 100-12800)EXPANDABLE TO h:25600(5)Dual Lens camera 55-250mm IS II lens 6) Camera battery charger and bag 7)Wide strap USB cable, software CD. as per Department Incharge 724 Supplying of 24.2MP DigitalSLR Camera:- 1)100% Viewfinder Coverage 2)CMOS sensor with impressive high-resolution result 3)Camera battery, charger, and bag 4)Wide strap USB cable, software CD, manual as per Department Incharge 725 Supplying of Quark express as per Department Incharge 726 Supplying of Adobe Suite(CS6 Master Collection) as per Department Incharge 727 Supplying of Cool Edit Pro as per Department Incharge 728 Supplying of Turnitin as per Department Incharge 729 Supplying of Sound Forge as per Department Incharge 730 Supplying of 18-55mm normal lens as per Department Incharge 731 Supplying of 55-250mm Zoom lens as per Department Incharge 732 Supplying of 18-135mm lens as per Department Incharge 733 Supplying of 35mm prime lens as per Department Incharge 734 Supplying of 80mm macro lensas per Department Incharge 735 Supplying of Tripods as per Department Incharge 736 Supplying of DSLR:- 1)Powered by NP-F570 InfoLithium rechargeble battery pack 2)Records to MiniDV tape stock 3)16:9 widescreen recording 4)3CCD video camera 5)12x optical zoom lens 6)Records to MiniDV tape stock as per Department Incharge 737 Supplying of:- 1)3CCD video camera 2) Crystal Engine 3)Shoulder -Type Design 3)One Touch Navigation 4)Manual Focus Ring 5) 0 lux colour light view 6)10x optical zoom 6)500x digital zoom 7)Super image stabilizer 8) DV IN/OUT Terminal 8)5-mode programme AE: sports, portrait, low light, spot light, and surf &snow 9)SP/I.P recording 10)Back light compensation 11) Cinema mode )16:9 aspect ratio( 12)Infra-red remote controller as per Department Incharge 738 Supplying of Tripods:- 1)3-way head with adjustable pan 2)Steady rubberized legs 3)Multipurpose head with quick release 4)Multipupose head for DV cameras 5)Made from High Grade Aliminium Alloy 6)Quik flip leg locks 7)Fluid pan&tilt movement 8)Quik release plate& Bubble Level as per Department Incharge 739 Supplying of i-Mac(Product Specification,Storage Capacity-256 GB Display-24 inch,Memory Size-256gb ssd,assembled Product Dimensions L X W X H,461 mm x 547 mm x 130 mm, 4.48 kg Color-Silver & Blue,Graphics-8_core GPU,Video Support And Camera 4.5K,Bluetooth-Bluetooth 5.0,Weight-4.48kg,Operating System-macOS Big Sur,Processor- M1Echip,Line Voltage-100-240V AC) for Video Editing as per Department Incharge 740 Supplying of Photographic Design Flash Bender-Small Reflector:- 1) Make a bounce flash reflector, gobo, or snoot 2)Packs flat/great for travel 3)Attaches quickly & securely 4)Adjustable to fit all popular brands of accessory flash 5)For on-camera or off-camera flash as per Department Incharge 741 Supplying of Rim Collapsible softbox Diffuser with Rim :-1)Softbox 36 inches/90 Centimeters with Grey Rim and Bowens Mount, Portable and Quick Folding Softbox Diffuser for Photography Speedlites Flash Monolight 2)for 660 LED Panel-Outer 16.3x6.5 inches,Inner 9.8x8.7 inches Collapsible Light Reflector 3)with Stap Attachment and Carrying Bag for Photo Studio Portrait Video Shooting as per Department Incharge 742 Supplying of Handheld Camera Stabilizer with Quik Release for DSLR:- 1)Light weight, handheld video image stabilization 2)FlyCam 3000 video cam stabilizer accepts camera upto 3.5kg/7.7Ibs. 3)Easy attach a small LCD monitor with Flycam 3000 cam stabilizer when needed. 4)Precision Aluminum made 5)23 tall and just 207 Ibs without counter balance disc. as per Department Incharge 743 Supplying of Green/Blue matte screen )Chroma key( :- 1)8x12 ft Blackboard, perfect for television, video production and digital photography. 2)Rod pocket on each top edge allows to be draped or hung. 3)Finishing along all edges to prevent tears. 4)Made of 100 %pure cotton, good vertical sense and durable as per Department Incharge 744 Supplying of Professional Grade Backdrop Cum Light Stand of 8 Feet Height:- 1)Photography Backdrop Stand Kit. 2)Stand of 8 Feet Height 3)8x12 ft Blackboard, perfect for television, video production and digital photography. 4) Package Contents; 1Pcs White Backdrop , 1Pcs Black Backdrop and Set of Black Backdrop stand. 5)Bag to carry as per Department Incharge 745 Supplying of Video Mixer (Four Channel Digital Video Mixer With Effects, including installation and training):- 1) four channel video mixer by incorportating HDMI inputs/outputs, USB streaming, HDCP support, built-in touch multi-viewer, and audio embedding . 2)(3Input)SD HDMI/Composite +(1Input) Up to1080p HDMI/RGB/Component/Composite. 3) PGM Output) Up to 1080p HDMI + RGB/Component +Composite +(PVW Output)PVW/Multiviewer(. 4)480p/576p Progressive internal processing 5.) Built-in multi-viewer ith touch control 6). Built-in frame synchronizers on all inputs 7). Scalers on CH 4 and Output 8). 259 Transitions 148 Effects 9). HDCP Compliant 10) Audio Embedding 11) Audio Mixer & Delay -up to 4 Fframes 12) USB Streaming Out for web-streaming 13) Video Processing:4:2:2 )Y/b/Pr(8 bits)Internal Processing :480/59.94p when set to NTSC, 576/50p when set to PAL( 14) Input Formats :HDMIVideo: INPUT 1 to3 : reqyires 720x480/59.94p )when set to NTSC( 576/50p ) When set to PAL(15) Input Formats : HDMI and Component Video : INPUT 4:480/59.94p, 720/59.94p, 1080/59.94i, 1080/59.94p )when set to NTSC (576/50i, 576/50p, 720/50p, 1080/50i, 1080/50p )when set PAL( as per Department Incharge 746 Supplying of Studio Condenser Microphone :- 1)Professional, large-diaphragm condenser microphone for unsurpassed audio quality 2) Idea as Mian and support microphone for studio and live applications. 3) Cardioid pickup pattern for outstanding sound source separation and feedback rejection 4)Pressure-gradient transducer with shock-mounted capsule. 5)Ultra-low noise, transformerless FET inputeliminates low-frequency distortion. 6) LED indicates phantom power operation. 7)Swivel stand mount and transport case included. 8)Ultra-rugged construction with metal die-cast body 8)Gold-plated 3-pin XLR output connector for highest signal integrityas per Department Incharge 747 Supplying of Digital Monitor/Speaker System(in Pair) :- 1)Two-way active monitor system for multimedia workstations and keyboard monitoring 2)High-power woofers and tweeters powered provided a linear frequency response 3)optical and coaxial inputs to directly connect digital audio sources via S/PDIF interface 4)Two stereo analogue inputs featuring 1/8 TRS and stereo RCA connectors can be used simultaneously or mixed with a digital stereo source 5)Features 1/4 TRS headphone connector with auto-mute function easily accessible from the front panel 6)2x Stereo Anaog Inputs )TRS and Stereo RCA Connectors( 7) 1/4-inch TRS headphone connector with Auto-mute Loudspeaker Function 8)1/8-inch TRS and Stereo RCA connectors as per Department Incharge 748 Supplying of Lapel Clip-on Microphone for DSLRs Camcorders Video Cameras and Iphone Smart Phone :- 1)Omni directional lavalier microphone, designed for Smartphones, DSLR, Camcorders, Audio recorders PC etc, perfect for video use. 2) With Omni pickup pattern, for full 360A coverage, 3) minimum 6-meter )20(cable with 3.5mm 4-pole gold plug for smarty phone connection as per Department Incharge 749 Supplying of Micophone Stand:- Steel stands for hand held microphones in studio with a base supporting system as per Department Incharge 750 Supplying of MP3 Digital Voice IC Recorder LCD :- 1)Digital Voice IC Recorder 2)LCD Screen 3) 23hrs life with 4GB Memory as per Department Incharge
Contract Date: Jun 17, 2026 Contract Value : 78.07 Crore
Government Departments No of Bidders 9
17.
Drinking Water Supply and Sanitation #10084992 Price Bid
Scada System For Srbc Kc Canal Tgp Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Scada System ( Automation Of Gate Operations ) For Head Regulators Of Srisailam Right Bank Canal ( Srbc ) , Kurnool-Kadapa Canal ( Kc Canal ) And Telugu Ganga Canal System , Local Control System , Supply Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc / Rtu / As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 8 M Range For Measuring Level / Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast / Cantilever As Per Technical Specification. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Canal System With Bed Width Of As Per The Site Required, Including Integration With Plc / Rtu Complete As Per Technical , Supply Of Automated Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Upstream Level On Head Regulators Of Sunkesula Barrage, Tgp Link Channel & Bcr Additional Head Regulator, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specification , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc / Rtu As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24- Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, And Communication With Scada Control Room Complete As Per Technical Specifications. . , Control Room Equipment’S , Supply, Engineering And Development Of Customized Scada Software For Head / Cross Regulator Automation With Life Time Licensed Version As Per Technical Specifications , Supply Of Industrial Grade Server Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete For Canal Network, As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With 42 Inch Led Display, 1 Kva Ups & 4G / 3G Dongles / Broadbandat Division Monitoring Station With Necessary Accessories As Per Technical Specifications , Supply Of Internet Connection And It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 55” Smart Led Display System For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Laptops & 4G / 3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Canal Automation As Per Technical Specifications , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Control Room For Establishment Of Canal Scada Control Room Along With Necessary Electrical Fittings As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Andhra Pradesh View Result →
18.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
19.
Defence #9728185 AOC
Tender For Provision Of Barrack , Cook House, Bathroom And Toilet At Shillong Under Ge Shillong; 2 Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I 3 Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule A Part-II. 4 Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATIONas listed in Schedule A Part-III 5 Lumpsum price worked out by the bidder/ tenderer for HOT WATER SUPPLY as listed in Schedule A Part-IV. 6 Lumpsum price worked out by the bidder/ tenderer for REFRIGERATION as listed in Schedule A Part-V. 7 Lumpsum price worked out by the bidder/ tenderer for LIFT as listed in Schedule A Part-VI. 8 Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule A Part-VII. 9 Lumpsum price worked out by the bidder/ tenderer for ROAD , CULVERT AND HARDSTANDING as listed in Schedule A Part-VIII 10 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule A Part-IX. 11 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule A Part-X. 12 Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule A Part-XI. 13 Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule A Part-XII. 14 Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL , FENCING AND GATE as listed in Schedule A Part-XIII. 15 Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule A Part-XIV. 16 Sch A Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only. 17 S&F LED type bed side wall mounted light fitting 9/10 Watt , housing- glass, frosted type, metallic frame, adjustable type complete all as specified and directed. 18 S&F Modular blanking plate modular type suitable for fixing in modular switch board complete all as specified and as directed. 19 S&F Surge Protection Device (SPD) Single Phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed 20 S&F Modular modular type TV socket RJ46, 1 module complete all as specified and as directed. 21 S&F Modular modular type TV socket RJ 11, 1 module complete all as specified and as directed. 22 S&F power unit suitable for up to 2.00 Ton AC having push ON-OFF button switch, motor starter type, single phase, 4 module with and including modular metal flush box with cover plates complete all as specified and directed. (For AC) 23 Supply, installation, commissioning and testing of Indoor type LT feeder piller box of size 1.5 m x 1.5 m x 0.50 m ,indoorcubical type, floor mounted,totally enclosed with front and rear opening, hinged doors with projected and raised platform of suitable size, dust and vermin proof material including as per IS 8623 aluminium bus bar with insulators suitable for three phase and four wires LT AC, 50 Hz, 415 Volts, 400 Amp capacity factory made of CRCA Sheet 2.0 mm thick powder coatedand MS angle of size 40x40x5mm having suitable legs, double door both side openable with locking and key arrangement with two Nos pad lock50 mm complete all as directed and comprising of the following:- (For single living ORs Accn 11 Hav & 169 ORs)(a) INCOMING(i) MCCB, 4 Pole, 415 Volts, 250 Amps, breaking capacity 36 KA with microprocessor release - 01 No(ii)LED indicating lamp with holder for main supply indicating RYB (set of three) - 01 Set(iii) On load change over switch 3 phase, 4 wire system, AC, 50 Hz, 400 Amp capacity - 01 No.(iv) Housing and making connection of 3 phase, 4 wire CT operated smart energy meter. ( CT operated smart energy meter catered here in after)(b) OUTGOING(i) MCCB, 4 Pole, 415 Volts, 100 Amps, breaking capacity 16 KA adjustable type - 05 Nos ( 04 Nos for floor & 1 No. as spare)(ii)Digital multifunction meter of size 96 x 96 mm to measure current, Voltage, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port.(iii) Aluminium bus bar of rating 400 Amps, insulated, 3 phase, 4 wire system. 24 Supply , installation, testing and comission of Smart energyMeter (IS-16444), AC whole current, three phase, 4 wires CT Operated Smart Energy Meter of Class 0.5 S, 415 Volts, 50 Hz, 1b 5 A complete as specified in CEA notification.The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technolog. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangement of suitable size as per the requirement of OEM of Electric meter. The cost of meter would be included the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 HZ and voltage class 660 Volts effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as specified and directed. NOTE:(a) The bidder shall provide replacement warranty of 5 Years from the date of activation of smart meter for any type of Defect/ Fault/ Error in reading/ Non functioning of smart feature.(b)CT to be provided at incommer side of MCCB in main LT panel of the Building. 25 Supply , installation, testing and comission of Smart energy prepaid Meterconfirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty. 26 S&F perforated cable tray standard type C, made out of hotdip galvanised sheet having thickness not less than 1.2 mm thick foxed on wall up to 4th floor high building including necessary bracket for fixing and all accessories like bend, elbow etc suitable for housing single cable up to 25 Sqmm 4 core at each floor complete all as specified and directed. 27 Supply Installation and testing of Refrigerator double door run on digital inverter technology with latest specification or features of capacity 320 Ltrs with 5 star rated complete all as specified and directed 28 S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of+ 2.5% and of cap 4 Amps ( 1.0 KVA) complete all as specified and directed. 29 Design, Supply, Installation, Testing and commissioning incl comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 30 KWp (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed 30 Design, Supply, Erection, Testing and commissioning incl comprehensive maint for 7 years of Roof Top Solar Power Generation Plant of capacity 10 KWp (AC) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with batteries back up for captive use as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications andtechnical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed 31 Design, Construction, Supply, installation, testing and commissioning of compact & concealed designed Sewage Treatment Plant of capacity 20 KLD based on Johkasou technology / (MBBR) Moving Media Bio Reactor Technology / PeMBR technolgyincluding fully automation system (Scada System), modular Pre- constructed systems having sedimentation and seperation chamber, anaerobic contact media chamber, moving bed chamber (Aerobic), sedimentation chamber, disinfectant chamber and tertiary treatment plant, including operation and maintenance for a period of 5 years from the date of completion of work including all consumable except power, with adequate manpower to ensure no downtime of plant and provide consistent outlet parameters, the plant shall be having least energy and operating cost and No noise during operation, complete and including the following:- 32 Continued serial item No. 15.015(a) Bar screen (Mesh) 500mm x 500mm, made of MS FRP coated, and bar spacing 10 mm complete as per OEM recommendations.(b) Cylindrical type reactor made of FRP complete as per OEM recommendation.C)Air blowerofcapacityas per OEM recommendations complete - 03 Nos.(d) Filter Feed Pump , Non-clog submersible pump of capacity as per OEM recommendations - 02 Nos ( One working + One Standby).(e)Pressure sand filter ofcapacity as per OEM recommendations, made of FRP, having vessel size 18 dia x 65 height and having Gravels/Pebbles/Core Silex/Fine Silex/ Sand as filter mediacomplete with necessary PVC piping complete - 01 Set.(f) Activated Carbon filter of capacity as per OEM recommendations, made of FRP, having vessel size 18 dia x 65 height and having 1200 I/V Activated carbonfilter mediacomplete with necessary PVC piping complete - 01 Set.(g) Chlorine (Sodium Hypochlorite Dosing) System having Dosing pump of capacityas per OEM recommendations and including HDPE Dosing drum of minimum cpacity 50 Litrs complete - 01 Lot.(h) Raw sewage Transfer Pump of capcity as per OEM recommendations complete - 02 Nos ( One working + One Standby).(j)One No. PLC Panel for operation of the plant as per OEPL standard & cabling with in the plant range complete.(k)Necessary piping & valves as per OEM recommendations within the plant range complete - 01 Lot(l)All as per Scope of Work & Technical Specification for 20 KLD STP given in particular specification 33 Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 28 KW 35 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering28 KW(35 KVA) atoutdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . 34 Continued serial item No. 15.016(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 28 KW(35 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class H, salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: - Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn. 35 Continued serial item No. 15.016Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturers drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil. 36 Supply, fixing and testing DI fittings for spigot and socketed or flanged pipes i.e bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers, gaskets etc of sizes 80 mm to 150 mm dia complete all as specified and directed. 37 M&L for construction of brick masonry valve pit of size 900 x 900 x 900 mm(internal dimension) one brick thick wall in CM (1:4) on 100 mm thick PCC (1:4:8) type D-2 (40mm graded crushed stone aggregate)foundation, 15mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below GL, providing valve pit cover made of 3 mm thick MS sheet/plate, providing and welded hinges, handle , locking arrangement, 50 X 50 X 6 mm angle iron frame fixed on top of valve pit by means of 4 Nos of hold fast 150 mm long, embedded in PCC block (1:2:4) type B-1 (20mm graded crushed stone aggregate) of size 230 x 200 x 100 mm and applying two coats of synthetic enamel paint over a coat of red oxide primer includingnecessary earth work in soft/loose soil complete all as specified & directed. 38 Cutting road upto one feet depth for insertion of cable protection pipe complete all as specified and directed.Note: cable protection pipe and PCC for refilling will be measured and paid separately 39 Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing MCCB’s including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crushed stone aggregate up to 30 cm complete as per IS 8623, IEC 60947 & IS 13947: 1993 complete all as specified and directed. (Panel 1)(a) INCOMING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 250 Amp with breaking capacity 36 KA 40 Continued serial item No. 15.020(ii) Smart energy Meter(IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter ofClass 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(iii) Phase indicator lamps (RYB) - 01 set(b) OUTGOING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 200 Amp with breaking capacity 25 KA- 01 No (to panel 2)(ii)MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 160 Amp with breaking capacity 25 KA- 02 Nos (to barrack 1W+1S)(iii) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 63 Amp with breaking capacity 16 KA- 01 No (CH and DH)(iv) MCB TPN 20 Amps 10 KA - 01 No (C-Curve) (Street light)(v) Digital timer-01 No(vi) Power contractor -01 No 41 Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing MCCB’s including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crushed stone aggregate up to 30 cm complete as per IS 8623, IEC 60947 & IS 13947: 1993 complete all as specified and directed. (Panel 2)(a) INCOMING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 150 Amp with breaking capacity 36 KA 42 Continued serial item No. 15.021(ii) Smart energy Meter(IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter ofClass 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(iii) Phase indicator lamps (RYB) - 01 set(b) OUTGOING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 63 Amp with breaking capacity 25 KA- 03 Nos (to JCO single living & OC office)(ii)MCB 4 pole, 415 V, 32 Amp with breaking capacity 10 KA- 01 No (to store)(iii) MCB TPN 20 Amps 10 KA - 01 No (C-Curve) (Street light)(iv)Digital timer-01 No(v) Power contractor -01 No 43 S&F PVC Junction box of size 270 X 225 X 135 mmwiith 2 way connector mounted on epoxy insulators for looping of cablefor 1Phase and1neutral fixed on polewith the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X4 mm thick . Work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to conector of street light complete all as specified and directed. 44 M&L for DWCP HDPE pipe SN 8 ,100 mm dia complete all as specified and directed. 45 S&F galvanised concertina razor wire BTO 22 galvanised steel, core wire diameter 2.5 mm dia, blade thickness 0.5 mm, length 22 mm, width 15 mm, number of loops 33 , clips per spiral 03 numbers, stretch length 8 to 10 meter per roll, breaking load 150 to 160 Kg/Sqmm , weight per roll 11.50 Kg, dia of roll 450 mm should be packed in water proof paper and wooden box complete all as specified and directed. 46 Construction ofRCC bridge (Two lane) of size 18 m span and 5.50 m width complete allas specified and shown on drawings.
Contract Date: Apr 23, 2026 Contract Value : 14.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
20.
Power #9638696 AOC
Tender For Construction Of 220/132 Kv, 1X160 Mva;Substation At Balesar (Upgradation)Including Survey Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning On Turnkey Basis Against Specification No. Rvpn/Ehv/Bn-9019002512. - Circuit Breaker 3 220kV circuit breakers (3 Ph.) Along with support Structure 4 2500 A, 50 kA 5 132 kV Circuit Breakers 6 132 kV circuit breakers (3 Ph.) Along with support Structure 7 1250 A, 40 kA 8 Instrument Transformers 9 Capacitor Voltage Transformer 10 Single-Phase, 220 kV, 4400 pf CVT 11 Single Phase 132 kV , 4400 pf CVT 12 Current Transformer (1-Phase) 13 220 kV CT 14 1000/1 A, 5C 15 132 kV CT 16 1000/1 A, 3C 17 500/1 A, 3C 18 C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II) 19 New Substation 20 Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB 21 Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB 22 Control Panel for 220 kV Feeder Type: SAS-FCB 23 Relay Panelfor 220 kV Feeder Type: SAS-FRB 24 Control Panel for 220 kV Bus Coupler Type: SAS-BCCB 25 Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB 26 220 kV Busbar Protection Relay Panel Type: SAS-BBRB 27 Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB 28 Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB 29 Control Panel for 132 kV Feeder Type SAS-FCA 30 Relay Panel for 132 kV Feeder Type SAS-FRA 31 Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA 32 Station HMI [Industrial grade Computer with 21TFT monitor as per specification requirements] 33 Station HMI (Hot Standby)[Industrial grade Computer with 21TFT monitor as per specification requirements] 34 HMI View Node[Industrial grad Computer with 21TFT monitor as per specification requirements] 35 A3 Size B&W Laser Printer 36 Substation Automation System Network Panel Type SAS-NW 37 Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC] 38 Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired 39 Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification. 40 Substation Auxiliary Monitoring Panel Type SAS-SAMP 41 Other Items: 42 Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements. 43 Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards. 44 Surge Arresters 45 220 kV LA 46 132 kV LA 47 Substation LT Transformer 48 33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil 49 Batteries & Battery Charger 50 Batteries (Sizing shall be as per requirement of technical specification) 51 220 V [Min. 600 AH] 52 48 V [Min. 600 AH] 53 Battery Charger System 54 220 V Float and Boost 55 50 V Float and Boost 56 Lighting System 57 Outdoor Lighting & other Works 58 Lighting Fixture Type FL-1 59 Lighting Fixture Type FL-2 60 Outdoor Receptacle 61 Type-RP 62 Type-RO 63 Substation Premises Lighting 64 Lighting poles 65 Type-L1 66 Type-D1 67 Street Lighting Type-SL-L1 for mounting on poles 68 Street Lighting Type-SL-D1 for mounting on Poles 69 Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc. 70 Lighting PanelType ACP-2 as per technical specification 71 Lighting PanelType ACP-3 as per technical specification 72 Indoor Lighting & Other Works 73 Electrification 74 Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room,Hall and administrative office building as per the requirements of the specifications 75 Illumiation 76 Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories andmounting arrangements) 77 Indoor Lignting Panels 78 Lighting Panel (Indoor)Type ACP-1 as per technical specification 79 Lighting Panel (Indoor)Type DCP as per technical specification 80 Wall mounted fans Approx. 400 mm sweep 81 Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator 82 Exhaust Fans 83 Fire Fighting System 84 DCP Type 85 i) 5 Kg. 86 ii) 10 Kg. 87 Carbon di oxide type – 6 Liters. 88 Foam Type- 9 Liters 89 Sand type 90 i) GI Buckets 9 liters capacity 91 ii) Steel Stands for four buckets 92 Air Conditioning System 93 Air Conditioning for the Rooms specified in the specifications 94 1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building] 95 Power Cables(XLPE) 96 3.5Cx300 sq.mm 97 Power Cable(PVC) 98 1Cx150 sq.mm 99 3.5Cx70 sq.mm 100 3.5Cx35 sq.mm 101 4Cx16 sq.mm 102 4C x 6 Sq. mm 103 2C x 6 Sq. mm 104 Control Cable (PVC) 105 4 CX4 Sq. mm 106 3Cx2.5 sq.mm 107 5Cx2.5 sq.mm 108 7Cx2.5 sq.mm 109 10Cx2.5 sq.mm 110 14Cx2.5 sq.mm 111 19Cx2.5 sq.mm 112 Substation Structures 113 Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]: 114 NON Standard Pipe supportStructure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe support structure as per specification requirements]: 115 Isolators 116 220 kV (3-Phase) (Horizontal DOUBLE BREAK) 117 1600A, 50KA, isolator with one E/S 118 Post insulators for above Isolator 119 1600A, 50KA, isolator without E/S 120 Post insulators for above Isolator 121 1600A, 50KA, isolator without E/S (TANDEM Type) 122 Post insulators for above Isolator 123 132 kV (3-Phase) (Horizontal DOUBLE BREAK) 124 1250A, isolator with one E/S 125 Post insulators for above Isolator 126 1250Aisolator without E/S 127 Post insulators for above Isolator 128 Switchyard Erection 129 Busbar & Interconnections 130 New Substation/ Switchyard 131 220 kV Switchyard Works: 132 Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/PorcelainLong Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 133 Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 134 Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 135 220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 136 Twin ACSR Zebra 137 Single ACSR Zebra 138 Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps,connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following: 139 220 kV DMT-type layout 140 Line bay 141 Transformer bay 142 Bus-Coupler 143 Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps,connectors, junction box including of all accessories etc. 144 132 kV Switchyard Works: 145 Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 146 Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 147 132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay),Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 148 Twin ACSR Zebra 149 Single Panther 150 Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV TransformerBay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps,connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following: 151 132 kV Main & Aux-type layout 152 Line bay 153 Transformer bay 154 Bus-Coupler 155 Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps,connectors, junction box including of all accessories etc. 156 LT Transformer connection with ACSR Panter conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors 157 Bus Post Insulators (BPI) 158 220 kV 159 132 kV 160 Earthing & Lightning Protection System 161 Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area 162 40 mm Dia MS Rod 163 40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven. 164 40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven. 165 40mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link 166 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works 167 75X12 mm GS Flat 168 50X6 mm GS Flat 169 Earth Enhancing Compound for treated pits as above and other requirement as per specification 170 Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat 171 Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats 172 Earth Wire for Shielding Protection of Switchyard 173 7/3.15 Galvenized Steel Wire 174 Earthwire tension clamps with D Shackle assembly 175 PG calmp to suit 7/3.15 mm GS earth wire 176 Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat 177 Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat 178 Lug to suit 7/3.15 mm earth wire 179 Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire 180 Bay Marshalling KIOSK 181 200 way (Stud Type Connectors) 182 AC Distribution Boxes (Outdoor Type) 183 Outdoor AC Distbibution Box (Double Front type) 184 Outdoor AC Distbibution Box (Single Front type) 185 Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building] 186 Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washersetc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works] 187 LT Switchgear 188 LT AC Main Panel 189 LT AC Distribution Board 190 Main Lighting Distribution Board 191 Emergency Lighting Distribution Board 192 220VDCDB 193 48V DCDB 194 PLCC EQUIPMENTS 195 220 kV, 0.5mH / 1250 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end. (Suspension Type) 196 132 kV, 0.2mH / 1000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end. (Suspension Type) 197 4 kHz to 16 Khz channel digital PLCC carrier terminal with digital protection coupler (DTPC), IEC 101& 104 data and 4W E&M speech applications 198 4 kHz to 16 Khz channel digital PLCC carrier terminal without digital protection coupler (DTPC), IEC 01& 104 data and 4W E&M speech applications 199 VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel) 200 Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level. 201 Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level. 202 HF Armoured Coaxial cable having 75 Ohms unbalanced impendance. 203 PLCC Electronic Private Automatic Exchange (EPAX) suitable for 32 subscribers lines and 16 tie lines with redundancy of critical cards. 204 Telephone Sets (Push Button Type) 205 10 pair Jelly Filled and armoured telephone cable with copper conductor of 0.63 mm 206 5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm 207 5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm 208 Print testing kit (for digital PLCC panel) 209 TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS 210 (A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements] 211 Insulation Tester (5000 Volts, Digital) 212 SF6 Leakage Detector 213 Digital Multimeter 214 Digital Clamp Meter 215 (B) Maintenance Tools& Tackles 216 Oil Sampling Bottle (1 Liter Capacity) 217 Vaccum Cleaner 218 Telescopic ladder aluminium 6 meter height 219 Ring spanner set 220 Tube spanner set 221 Pipe wrench 24 inch 222 Pipe wrench 18 inch 223 Hydraulic crimping tools up to 630 sq.mm 224 Threading die set for pipe threading 225 Welding machine (arc welding) 10kVA 226 Heavy duty drilling machine 227 Bench Vice 228 Insulated cuttingplier 12 inch 229 Insulated cuttingplier8 inch 230 Screw driver 18 inch 231 Screw driver 12 inch 232 Hammer 8 lbs 233 Hammer 2 lbs 234 Chain pulley block 5 ton 235 Pipe derrick 236 Allen Keys 237 Box Spanners 238 (C )Office and Miscellaneous Equipments/ Items 239 Insulation Rubber mat (1mX2mX 12 mm) 240 Isulation Rubber Gloves (33 kV Tested) 241 Furniturefor Control Room Building: 242 SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification 243 Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet) 244 Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet). 245 Library Shelf with Glass Door (min 4 Shelf) 246 Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane. 247 Archival Storage 4 Drive Type 248 Lateral Filing Cabinets 249 3 Drawer Unit 250 4 Drawer Unit 251 Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 252 Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 253 Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system. 254 Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage). 255 Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG. 256 Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage 257 Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round. 258 Key board (wooden) with Glass door 259 First Aid Box 260 Shock Treatment Chart [Laminated with Frame] 261 Safety Instruction Boards [ Laminated with Frame] 262 (D) Drinking Water Arrangement 263 Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr) 264 RO/ Water Purifier 265 Refrigirator (380 Lt.) 266 Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner] 267 Danger Plate [Size and Color etc. be got approved from owner] 268 MANDATORY SPARES 269 (A )Circuit Breakers 270 220 KV 271 (One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism. 272 Rubber gaskets, ‘O’ rings and seals 273 Fixed Contacts 274 Moving Contacts 275 Terminal pads and connectors 276 Closing Assembly Valve 277 Trip Assembly Valve 278 Auxiliary Switch Assembly 279 Operation Counter 280 Closing Coils 281 Tripping coils 282 Support insulator complete for one pole of breaker 283 145 kV 284 One pole of circuit breakerwithout support structure and operating mechanism. 285 Rubber gaskets, ‘O’ rings and seals 286 Fixed Contacts 287 Moving Contacts 288 Terminal pads and connectors 289 Closing assembly valve 290 Trip assembly valve 291 Auxiliary switch assembly 292 Operation counter 293 Closing Coils 294 Tripping coils 295 Support insulator (set complete for one pole of breaker) 296 Instrument Transformer 297 Spare of 245kVCapacitive Voltage Transformer 298 (i)Complete CVT 299 Spare of 145kVCapacitive Voltage Transformer 300 (i)Complete CVT 301 Spare of 245kVCurrent Transformer 302 (i)Complete CT [1 No. each type supplied) 303 Spare of 145kVCurrent Transformer 304 (i)Complete CT (1 No. each type supplied) 305 (E) C&R panels (similar items as used in the quoted panels) 306 Bay Control Unit (220 kV Side of offered type) 307 Bay Control Unit (132 kV Side of offered type) 308 Bay Control & Protection Unit (33 kV Side of offered type) 309 Bay Unit (For 220 kV Busbar Protection of offered type) 310 Bay Protection Unit (Distance for 220 kV Feeders of offered type) 311 Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type) 312 Bay Protection Unit (Distance for 132 kV Feeders of offered type) 313 Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I) 314 Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II) 315 Bay Protection Unit (Differential for 132 kV Transformers of offered type) 316 Bay Protection Unit (Back-up Overcurrent & E/F of offered type) 317 Breaker failure relay (numerical type) 318 Trip circuit supervision relay 319 Self reset trip relay 320 Hand reset trip relay 321 Timer relay 322 DC supervision relays 323 Flag relays 324 Auxiliary relays 325 Multifunction Panel Meter 326 Fiber Optic Cable with Connectors 327 Transducers (Each Type used in the autoamtion system) 328 Ethernet Switch (of offered type) 329 (F) Station Transformer 330 10% of total Transformer Oil quantity in non-returnable drums 331 HV bushing 332 LV bushing 333 Pressure relief device 334 Tap charger contact 335 Set of valves 336 Set of gasket 337 Silica gel required for five replacements 338 (G) Surge Arrester 339 220kV class 198 kV rating LA complete as specified. 340 132kV class 120 kV rating LA complete as specified. 341 2 Nos. Terminal connector of each type as spare 342 (H) Battery & Battery Charger 343 220 V& 48 V Type Battery 344 Spare battery cell without electrolyte 345 Terminal connectors with bolts & Nuts 346 Float level indicators 347 Vent Plugs 348 220V/ 50V Battery Chargers 349 Set of Control Cards 350 Set of relays 351 Set of contactor 352 Micro-switches 353 Filter Capacitors 354 Thyristor/ Diode 355 Set of switches 356 Set of wound resistors 357 Potentiometers 358 Fuses of Thyristor with indicators 359 (I) L.T. SWITCHGEAR : 360 Relays 361 CTs AND PTs 362 Switches/Push buttons and Meters 363 TPN Switches/MCB 364 L.T. Breaker spares 365 a) Spring charging motor 366 b) Aux. Contact sets 367 c) Busbar Seal off insulators 368 d) Arc-chutes 369 e) Moving contacts 370 f) Arcing contacts (Fixed/Moving) 371 g) Springs (Closing/Opening) 372 h) Closing coil 373 i) Tripping coil 374 j) Aux. finger contact 375 k) Limit switches 376 l) Jaw contacts 377 Busbar 378 a) Busbar insulators 379 b) Interphase barrier 380 c) Busbar strip 1mm (Aluminium) 381 (J) LIGHTING SYSTEM 382 Single Pole MCB 383 Triple pole MCB 384 Fluorescent tube & Starter 385 a) Choke 386 b) Bottom Strips 387 c) Top covers & reflector (if applicable) 388 d) Holders 389 e) Complete fittings 390 Sodium vapour/Mercury vapour Lamps a) Lamp 391 b) Ballast 392 c) Condenser/ Igniter 393 d) Lamp holder 394 e) Lamp holder 395 f) Complete fittings 396 Incandescent lamp 397 a) Bulbs 398 b) Holders 399 c) Complete fittings 400 Switches and sockets 401 Junction box 402 Celing Fan 403 (K) Clamps & Connectors Set 404 (M) Isolators 405 220 kV 406 Solid core Insulator Stacks (Requirement of one Isolator) 407 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 408 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 409 Motor with gear assembly and bevel gear assembly. 410 Bearings (Requirement of one Isolator) 411 Current carrying assembly total (Requirement of one Isolator) 412 132 kV 413 Solid core Insulator Stacks (Requirement of one Isolator) 414 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 415 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 416 Motor with gear assembly and bevel gear assembly. 417 Bearings (Requirement of one Isolator) 418 Current carrying assembly total (Requirement of one Isolator) 419 Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
Contract Date: Feb 22, 2026 Contract Value : 52.23 Crore
Government Departments No of Bidders 5
21.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
22.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
23.
Housing Urban and Rular Development #9488962 Technical Bid
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
24.
Housing Urban and Rular Development #9481199 Technical Bid
Tender For Special Repair& Maintenancework At Jnv Gumla, Jharkhand. - SCHOOL BUILDING 2 Structural Repair & Retrofitting 3 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 4 50mm average thickness 5 25 mm average thickness 6 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 7 Bars upto 12 mm diameter 8 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 9 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 10 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 12 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 13 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 14 Expansion Joint Treatment 15 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 16 Floor Joint of 100 mm gap 17 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 18 Wall Joint of 100 mm gap 19 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 20 Roof Joint of 100 mm gap 21 Repairs to Roof 22 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 23 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 24 Repair to Toilets 25 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 26 For thickness of tiles 10 mm to 25 mm 27 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 28 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 30 Providing and filling of cinder in sunken portion. 31 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 32 75 to 80 mm dia pipe 33 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 34 15 mm to 40 mm nominal bore 35 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 36 Up to 150 mm diameter 37 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 38 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 39 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 40 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 41 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 42 Rectangular manhole 90x80 cm and 45 cm deep 43 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 44 110 mm diameter 45 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 46 a) Coupler 47 110 mm 48 b) Bend 87.5° 49 110 mm bend 50 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 51 75 mm diameter pipes 52 100 mm diameter pipes 53 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 54 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 55 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 56 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 57 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 58 10 litre capacity - White 59 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 60 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 61 a) 32mm dia (for wash basin) 62 b) 40mm dia (for sink and urinal) 63 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 64 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 65 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 66 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 67 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 68 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 69 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 70 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 71 P-Trap type Floor Trap 110 x 75 mm 72 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 73 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 74 Providing and fixing 100 mm sand cast Iron grating for gully trap. 75 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 76 Providing & fixing soil, waste and vent pipes. 77 a) 100mm dia centrifugally cast iron S & S pipe. 78 b)75mm dia centrifugally cast iron S & S pipe. 79 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 80 a) for 100mm dia pipe. 81 b) for 75mm dia pipe. 82 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 83 a) 100mm 84 Sand cast iron S&S as per IS - 3989 85 b) 75mm 86 Sand cast iron S&S as per IS- 3989 87 Providing and fixing plaincast iron S & S sanitary bend. 88 a) 100mm 89 Sand cast iron S&S as per IS - 1729 90 b) 75mm 91 Sand cast iron S&S as per IS - 3989 92 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 93 a) 100x100x100mm 94 b) 75x75x75mm 95 Providing and fixingcast iron terminal guard. 96 a) 100mm 97 b) 75mm 98 Providing & fixingcast iron coller. 99 a)100 mm 100 Sand cast iron S&S as per IS - 3989 101 b)75mm dia. 102 Sand cast iron S&S as per IS - 3989 103 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 104 a) 100mm 105 b) 75mm 106 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 107 a) 100mm inlet & 75mm outlet. 108 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 109 Providing and fixing PTMT urinal cock of approved quality and colour. 110 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 111 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 112 15 mm nominal outer dia Pipes 113 20 mm nominal outer dia Pipes 114 25 mm nominal outer dia Pipes 115 32 mm nominal outer dia Pipes 116 Providing and fixing brass stop cock of approved quality. 117 15 mm nominal bore 118 Providing and fixing gun metal gate valve with wheel of approved quality. 119 a) 25mm dia nominal bore 120 b) 32mm dia nominal bore 121 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 122 a) 25mm. Nominal bore 123 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 124 a) 15mm nominal bore 125 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 126 a) 15mm nominal bore 127 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 128 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 129 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 130 a) 15mm nominal bore 131 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 132 a) 15mm nominal bore 133 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 134 15mm nominal bore 135 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 136 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 137 25mm nominal bore, weighing not less than 62 gms 138 Cutting holes up to 30x30 cm in walls including making good the same: 139 With common burnt clay F.P.S. (non modular) bricks 140 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 141 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 142 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 143 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 144 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 145 Repair to Plaster and Plinth Protection 146 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 147 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 148 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 149 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 151 With cement mortar 1:4 (1cement: 4 coarse sand) 152 15mm cement plaster of mix : 153 1:6 (1 cement : 6 course sand) 154 6mm cement plaster to ceiling of mix : 155 1:3 ( 1 cement : 3 fine sand) 156 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 157 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 158 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 159 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 160 Old work (one or more coats) 161 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 162 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 163 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 164 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 165 Repairs to Door / Windows 166 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 167 Of area 3 sq. metres and below 168 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 169 Of area 3 sq. metres and below 170 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 171 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 172 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 173 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 174 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 175 Fixed to steel windows by welding 176 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 177 300 mm weighing not less than 200gms. 178 250 mm weighing not less than 150gms. 179 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 180 100X58X1.90 mm 181 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 182 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 183 300 x 10mm 184 200 x 10mm 185 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 186 125 mm 187 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 188 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 189 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 190 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 191 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 192 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 193 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 194 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 195 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 196 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 197 4.0 mm thick glass panes 198 Applying priming coat : 199 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 200 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 201 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 202 Two or more coats on new work 203 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 204 One or more coats on old work 205 Repairs to Flooring 206 Miscellaneous 207 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 208 In cement mortar 209 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 210 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 211 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 212 Edges of slabs and breaks in floors and walls 213 Under 20 cm wide 214 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 215 Suspended floors, roofs, landings, balconies and access platform. 216 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 217 Thermo-Mechanically Treated bars of grade Fe-500D or more. 218 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 219 Cement mortar 1:6 (1 cement : 6 coarse sand) 220 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 221 Cement mortar 1:4 (1 cement :4 coarse sand 222 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 223 ELECTRICAL WORK OF SCHOOL BUILDING 224 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 225 Group C 226 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 227 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 228 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 229 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 230 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 231 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 232 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 Group C 234 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 235 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 x 1.5 sq. mm 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm X 100 mm X 60 mm deep 242 150 mm X 75 mm X 60 mm deep 243 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 244 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 245 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 246 Supplying and fixing brass batten/ angle holder including connection etc. as required. 247 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 248 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 249 4 way (4 + 12), Double door 250 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 251 Single pole 252 Single pole and neutral 253 Triple pole 254 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 255 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 256 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 257 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 258 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 259 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 260 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 261 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 262 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 263 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 264 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 265 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 266 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 267 MP HALL 268 Repairs to Roof: 269 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 270 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 271 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 272 Repair to Plaster and Plinth Protection 273 12 mm cement plaster of mix : 274 1:6 (1 cement : 6 course sand) 275 White washing with lime to give an even shade: 276 New work (three or more coats) 277 Repairs to Door / Windows 278 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 279 Of area 3 sq. metres and below 280 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 281 Of area 3 sq. metres and below 282 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 283 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 284 Fixed to steel windows by welding 285 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 286 300 mm weighing not less than 200gms. 287 250 mm weighing not less than 150gms. 288 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 289 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 290 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 291 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 292 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 293 4.0 mm thick glass panes 294 Applying priming coat : 295 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 296 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 297 Two or more coats on new work 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 299 One or more coats on old work 300 Miscellaneous 301 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 302 In cement mortar 303 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 304 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 305 Cement mortar 1:6 (1 cement : 6 coarse sand) 306 Boys Dormitories(CBRI Type) - 6 Blocks, Total Beds= 6x40 =240 307 Structural Repair & Retrofitting 308 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 309 50mm average thickness 310 25 mm average thickness 311 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 312 Bars upto 12 mm diameter 313 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 314 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 315 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 316 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 317 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 318 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 319 Repairs to Roof 320 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 321 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 322 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 323 Repair to Toilets 324 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 325 For thickness of tiles 10 mm to 25 mm 326 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 327 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 328 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 329 Providing and filling of cinder in sunken portions. 330 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 331 75 to 80 mm dia pipe 332 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 333 15 mm to 40 mm nominal bore 334 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 335 Up to 150 mm diameter 336 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 337 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 338 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 339 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 340 Up to 150 mm diameter 341 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 342 Rectangular manhole 90x80 cm and 45 cm deep 343 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 344 110 mm diameter 345 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 346 a) Coupler 347 110 mm 348 b) Bend 87.5° 349 110 mm bend 350 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 351 75 mm diameter pipes 352 100 mm diameter pipes 353 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 354 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 355 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 356 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 357 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 358 a) 32mm dia (for wash basin) 359 b) 40mm dia (for sink and urinal) 360 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 361 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 362 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 363 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 364 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 365 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 366 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 367 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 368 P-Trap type Floor Trap 110 x 75 mm 369 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 370 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 371 Providing and fixing 100 mm sand cast Iron grating for gully trap. 372 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 373 Providing & fixing soil, waste and vent pipes. 374 a) 100mm dia centrifugally cast iron S & S pipe. 375 b)75mm dia centrifugally cast iron S & S pipe. 376 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 377 a) for 100mm dia pipe. 378 b) for 75mm dia pipe. 379 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 380 a) 100mm 381 Sand cast iron S&S as per IS - 3989 382 b) 75mm 383 Sand cast iron S&S as per IS- 3989 384 Providing and fixing plaincast iron S & S sanitary bend. 385 a) 100mm 386 Sand cast iron S&S as per IS - 1729 387 b) 75mm 388 Sand cast iron S&S as per IS - 3989 389 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 390 a) 100x100x100mm 391 b) 75x75x75mm 392 Providing and fixingcast iron terminal guard. 393 a) 100mm 394 b) 75mm 395 Providing & fixingcast iron coller. 396 a)100 mm 397 Sand cast iron S&S as per IS - 3989 398 b)75mm dia. 399 Sand cast iron S&S as per IS - 3989 400 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 401 a) 100mm 402 b) 75mm 403 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 404 a) 100mm inlet & 75mm outlet. 405 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 406 15 mm nominal outer dia Pipes 407 20 mm nominal outer dia Pipes 408 25 mm nominal outer dia Pipes 409 32 mm nominal outer dia Pipes 410 Providing and fixing brass stop cock of approved quality. 411 15 mm nominal bore 412 Providing and fixing gun metal gate valve with wheel of approved quality. 413 a) 25mm dia nominal bore 414 b) 32mm dia nominal bore 415 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 416 a) 25mm. Nominal bore 417 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 418 a) 15mm nominal bore 419 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 420 a) 15mm nominal bore 421 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 422 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 423 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 424 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 425 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 426 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 427 a) 15mm nominal bore 428 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 429 a) 15mm nominal bore 430 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 431 15mm nominal bore 432 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 433 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 434 25mm nominal bore, weighing not less than 62 gms 435 Cutting holes up to 30x30 cm in walls including making good the same: 436 With common burnt clay F.P.S. (non modular) bricks 437 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 438 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 439 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 440 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 441 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 442 Repair to Plaster and Plinth Protection 443 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 444 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 445 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 446 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 447 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 448 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 449 With cement mortar 1:4 (1cement: 4 coarse sand) 450 12mm cement plaster of mix : 451 1:6 (1 cement : 6 course sand) 452 6mm cement plaster to ceiling of mix : 453 1:3 ( 1 cement : 3 fine sand) 454 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 455 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 456 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 457 Old work (one or more coats) 458 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 459 Repairs to Door / Windows 460 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 461 Of area 3 sq. metres and below 462 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 463 Of area 3 sq. metres and below 464 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 465 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 466 Renewal of old putty of glass panes (length) 467 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 468 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 469 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 470 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 471 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 472 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 473 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 474 With 12 mm mild steel U beading 475 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 476 300 mm weighing not less than 200gms. 477 250 mm weighing not less than 150gms. 478 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 479 100X58X1.90 mm 480 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 481 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 482 300 x 10mm 483 150 x 10mm 484 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 485 125 mm 486 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 487 Using flats 30x6mm for diagonal braces and central cross piece 488 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 489 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 490 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 491 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 492 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 493 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 494 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 495 4.0 mm thick glass panes 496 Applying priming coat : 497 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 498 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 499 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 500 Two or more coats on new work 501 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 502 One or more coats on old work 503 Miscellaneous 504 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 505 In cement mortar 506 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 507 Cement mortar 1:6 (1 cement : 6 coarse sand) 508 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 509 Cement mortar 1:4 (1 cement :4 coarse sand 510 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 511 ELECTRICAL WORK OF BOYS DORMITORY 512 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 513 Group B 514 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 515 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 516 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 517 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 518 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 519 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 520 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 521 Group B 522 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 523 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 524 2 x 1.5 sq. mm 525 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 526 25 mm 527 32 mm 528 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 529 100 mm X 100 mm X 60 mm deep 530 150 mm X 75 mm X 60 mm deep 531 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 532 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 533 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 534 Supplying and fixing brass batten/ angle holder including connection etc. as required. 535 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 536 4 way (4 + 12), Double door 537 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 538 Single pole 539 Single pole and neutral 540 Triple pole 541 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 542 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 543 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 544 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 545 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 546 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 547 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 548 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 549 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 550 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 551 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 552 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 553 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 554 GIRLS - 40 (CBRI) - 2 BLOCKS 555 Structural Repair & Retrofitting 556 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 557 50mm average thickness 558 25 mm average thickness 559 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 560 Bars upto 12 mm diameter 561 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 562 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 563 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 564 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 565 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 566 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 567 Repairs to Roof 568 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 569 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 570 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 571 Repair to Toilets 572 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 573 For thickness of tiles 10 mm to 25 mm 574 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 575 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 576 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 577 Providing and filling of cinder in sunken portions. 578 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 579 75 to 80 mm dia pipe 580 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 581 15 mm to 40 mm nominal bore 582 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 583 Up to 150 mm diameter 584 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 585 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 586 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 587 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 588 Up to 150 mm diameter 589 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 590 Rectangular manhole 90x80 cm and 45 cm deep 591 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 592 110 mm diameter 593 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 594 a) Coupler 595 110 mm 596 b) Bend 87.5° 597 110 mm bend 598 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 599 75 mm diameter pipes 600 100 mm diameter pipes 601 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 602 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 603 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 604 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 605 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 606 a) 32mm dia (for wash basin) 607 b) 40mm dia (for sink and urinal) 608 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 609 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 610 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 611 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 612 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 613 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 614 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 615 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 616 P-Trap type Floor Trap 110 x 75 mm 617 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 618 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 619 Providing and fixing 100 mm sand cast Iron grating for gully trap. 620 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 621 Providing & fixing soil, waste and vent pipes. 622 a) 100mm dia centrifugally cast iron S & S pipe. 623 b)75mm dia centrifugally cast iron S & S pipe. 624 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 625 a) for 100mm dia pipe. 626 b) for 75mm dia pipe. 627 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 628 a) 100mm 629 Sand cast iron S&S as per IS - 3989 630 b) 75mm 631 Sand cast iron S&S as per IS- 3989 632 Providing and fixing plaincast iron S & S sanitary bend. 633 a) 100mm 634 Sand cast iron S&S as per IS - 1729 635 b) 75mm 636 Sand cast iron S&S as per IS - 3989 637 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 638 a) 100x100x100mm 639 b) 75x75x75mm 640 Providing and fixingcast iron terminal guard. 641 a) 100mm 642 b) 75mm 643 Providing & fixingcast iron coller. 644 a)100 mm 645 Sand cast iron S&S as per IS - 3989 646 b)75mm dia. 647 Sand cast iron S&S as per IS - 3989 648 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 649 a) 100mm 650 b) 75mm 651 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 652 a) 100mm inlet & 75mm outlet. 653 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 654 15 mm nominal outer dia Pipes 655 20 mm nominal outer dia Pipes 656 25 mm nominal outer dia Pipes 657 32 mm nominal outer dia Pipes 658 Providing and fixing brass stop cock of approved quality. 659 15 mm nominal bore 660 Providing and fixing gun metal gate valve with wheel of approved quality. 661 a) 25mm dia nominal bore 662 b) 32mm dia nominal bore 663 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 664 a) 25mm. Nominal bore 665 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 666 a) 15mm nominal bore 667 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 668 a) 15mm nominal bore 669 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 670 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 671 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 672 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 673 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 674 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 675 a) 15mm nominal bore 676 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 677 a) 15mm nominal bore 678 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 679 15mm nominal bore 680 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 681 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 682 25mm nominal bore, weighing not less than 62 gms 683 Cutting holes up to 30x30 cm in walls including making good the same: 684 With common burnt clay F.P.S. (non modular) bricks 685 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 686 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 687 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 688 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 689 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 690 Repair to Plaster and Plinth Protection 691 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 692 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 693 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 694 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 695 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 696 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 697 With cement mortar 1:4 (1cement: 4 coarse sand) 698 12mm cement plaster of mix : 699 1:6 (1 cement : 6 course sand) 700 6mm cement plaster to ceiling of mix : 701 1:3 ( 1 cement : 3 fine sand) 702 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 703 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 704 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 705 Old work (one or more coats) 706 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 707 Repairs to Door / Windows 708 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 709 Of area 3 sq. metres and below 710 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 711 Of area 3 sq. metres and below 712 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 713 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 714 Renewal of old putty of glass panes (length) 715 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 716 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 717 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 718 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 720 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 721 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 722 With 12 mm mild steel U beading 723 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 724 300 mm weighing not less than 200gms. 725 250 mm weighing not less than 150gms. 726 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 727 100X58X1.90 mm 728 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 729 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 730 300 x 10mm 731 150 x 10mm 732 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 733 125 mm 734 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 735 Using flats 30x6mm for diagonal braces and central cross piece 736 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 737 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 738 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 739 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 740 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 741 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 742 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 743 4.0 mm thick glass panes 744 Applying priming coat : 745 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 746 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 747 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 748 Two or more coats on new work 749 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 750 One or more coats on old work 751 Miscellaneous 752 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 753 In cement mortar 754 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 755 Cement mortar 1:6 (1 cement : 6 coarse sand) 756 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 757 Cement mortar 1:4 (1 cement :4 coarse sand 758 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 759 ELECTRICAL WORK OF GIRLS - 40 (CBRI) - 2 BLOCKS 760 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 761 Group B 762 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 763 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 764 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 765 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 766 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 767 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 768 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 769 Group B 770 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 771 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 772 2 x 1.5 sq. mm 773 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 774 25 mm 775 32 mm 776 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 777 100 mm X 100 mm X 60 mm deep 778 150 mm X 75 mm X 60 mm deep 779 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 780 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 781 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 782 Supplying and fixing brass batten/ angle holder including connection etc. as required. 783 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 784 4 way (4 + 12), Double door 785 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 786 Single pole 787 Single pole and neutral 788 Triple pole 789 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 790 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 791 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 792 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 793 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 794 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 795 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 796 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 797 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 798 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 799 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 800 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 801 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 802 Girls Dormitories(CPWD Type) 1 Block 803 Structural Repair & Retrofitting 804 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 805 50mm average thickness 806 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 807 Bars upto 12 mm diameter 808 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 809 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 810 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 811 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 812 Repairs to Roof 813 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 814 In cement mortar 815 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 816 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 817 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 818 Repair to Toilets 819 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 820 For thickness of tiles 10 mm to 25 mm 821 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 822 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 823 75 to 80 mm dia pipe 824 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 825 15 mm to 40 mm nominal bore 826 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 827 Up to 150 mm diameter 828 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 829 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 830 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 831 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 832 Up to 150 mm diameter 833 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 834 Rectangular manhole 90x80 cm and 45 cm deep 835 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 836 110 mm diameter 837 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 838 a) Coupler 839 110 mm 840 b) Bend 87.5° 841 110 mm bend 842 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 843 75 mm diameter pipes 844 100 mm diameter pipes 845 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 846 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 847 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 848 W.C. pan with ISI marked white solid plastic seat and lid 849 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 850 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 851 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 852 a) 32mm dia (for wash basin) 853 b) 40mm dia (for sink and urinal) 854 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 855 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 856 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 857 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 858 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 859 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 860 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 861 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 862 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 863 P-Trap type Floor Trap 110 x 75 mm 864 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 865 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 866 Providing and fixing 100 mm sand cast Iron grating for gully trap. 867 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 868 Providing and fixing toilet paper holder : 869 Vitreous china 870 Providing & fixing soil, waste and vent pipes. 871 a) 100mm dia centrifugally cast iron S & S pipe. 872 b)75mm dia centrifugally cast iron S & S pipe. 873 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 874 a) for 100mm dia pipe. 875 b) for 75mm dia pipe. 876 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 877 a) 100mm 878 Sand cast iron S&S as per IS - 3989 879 b) 75mm 880 Sand cast iron S&S as per IS- 3989 881 Providing and fixing plaincast iron S & S sanitary bend. 882 a) 100mm 883 Sand cast iron S&S as per IS - 1729 884 b) 75mm 885 Sand cast iron S&S as per IS - 3989 886 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 887 a) 100x100x100mm 888 b) 75x75x75mm 889 Providing and fixingcast iron terminal guard. 890 a) 100mm 891 b) 75mm 892 Providing & fixingcast iron coller. 893 a)100 mm 894 Sand cast iron S&S as per IS - 3989 895 b)75mm dia. 896 Sand cast iron S&S as per IS - 3989 897 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 898 a) 100mm 899 b) 75mm 900 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 901 a) 100mm inlet & 75mm outlet. 902 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 903 15 mm nominal outer dia Pipes 904 20 mm nominal outer dia Pipes 905 25 mm nominal outer dia Pipes 906 32 mm nominal outer dia Pipes 907 Providing and fixing brass stop cock of approved quality. 908 15 mm nominal bore 909 Providing and fixing gun metal gate valve with wheel of approved quality. 910 a) 25mm dia nominal bore 911 b) 32mm dia nominal bore 912 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 913 a) 25mm. Nominal bore 914 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 915 a) 15mm nominal bore 916 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 917 a) 15mm nominal bore 918 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 919 a) 15mm nominal bore 920 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 921 a) 15mm nominal bore 922 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 923 15mm nominal bore 924 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 925 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 926 25mm nominal bore, weighing not less than 62 gms 927 Cutting holes up to 30x30 cm in walls including making good the same: 928 With common burnt clay F.P.S. (non modular) bricks 929 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 930 Repair to Plaster and Plinth Protection 931 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 932 Two or more coats on new work 933 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 934 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 935 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 936 15mm cement plaster on rough side of single or half brick wall of mix 937 1:6 (1 cement : 6 course sand) 938 6mm cement plaster to ceiling of mix : 939 1:3 ( 1 cement : 3 fine sand) 940 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 941 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 942 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 943 Old work (one or more coats) 944 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 945 Repairs to Door / Windows 946 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 947 Of area 3 sq. metres and below 948 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 949 Of area 3 sq. metres and below 950 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 951 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 952 Renewal of old putty of glass panes (length) 953 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 954 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 955 250 mm weighing not less than 150gms. 956 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 957 100X58X1.90 mm 958 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 959 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 960 300 x 10mm 961 150 x 10mm 962 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 963 125 mm 964 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 965 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 966 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 967 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 968 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 969 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 970 With 12 mm mild steel U beading 971 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 972 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 973 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 974 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 975 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 976 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 977 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 978 4.0 mm thick glass panes 979 Applying priming coat : 980 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 981 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 982 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 983 Two or more coats on new work 984 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 985 One or more coats on old work 986 Miscellaneous 987 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 988 In cement mortar 989 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 990 Cement mortar 1:6 (1 cement : 6 coarse sand) 991 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 992 Cement mortar 1:4 (1 cement :4 coarse sand 993 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 994 ELECTRICAL WORK OF GIRLSDORMITORY (G) FOR 48 STUDENTS 995 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 996 Group B 997 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 998 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 999 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1000 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1001 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1002 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1003 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1004 Group B 1005 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1006 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1007 2 x 1.5 sq. mm 1008 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1009 25 mm 1010 32 mm 1011 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1012 100 mm X 100 mm X 60 mm deep 1013 150 mm X 75 mm X 60 mm deep 1014 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1015 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1016 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1017 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1018 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1019 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1020 4 way (4 + 12), Double door 1021 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1022 Single pole 1023 Single pole and neutral 1024 Triple pole 1025 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1026 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1027 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1028 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1029 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1030 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1031 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1032 BOYS DORM - CPWD ( 1 BLOCK) 1033 Structural Repair & Retrofitting 1034 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1035 50mm average thickness 1036 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1037 Bars upto 12 mm diameter 1038 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1039 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1040 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1041 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1042 Repairs to Roof 1043 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1044 In cement mortar 1045 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1046 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1047 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1048 Repair to Toilets 1049 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1050 For thickness of tiles 10 mm to 25 mm 1051 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1052 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1053 75 to 80 mm dia pipe 1054 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1055 15 mm to 40 mm nominal bore 1056 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1057 Up to 150 mm diameter 1058 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1059 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1060 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1061 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1062 Up to 150 mm diameter 1063 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1064 Rectangular manhole 90x80 cm and 45 cm deep 1065 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1066 110 mm diameter 1067 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1068 a) Coupler 1069 110 mm 1070 b) Bend 87.5° 1071 110 mm bend 1072 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1073 75 mm diameter pipes 1074 100 mm diameter pipes 1075 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1076 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1077 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1078 W.C. pan with ISI marked white solid plastic seat and lid 1079 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1080 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1081 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1082 a) 32mm dia (for wash basin) 1083 b) 40mm dia (for sink and urinal) 1084 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 1085 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1086 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 1087 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1088 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1089 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1090 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1091 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1092 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1093 P-Trap type Floor Trap 110 x 75 mm 1094 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1095 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1096 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1097 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1098 Providing and fixing toilet paper holder : 1099 Vitreous china 1100 Providing & fixing soil, waste and vent pipes. 1101 a) 100mm dia centrifugally cast iron S & S pipe. 1102 b)75mm dia centrifugally cast iron S & S pipe. 1103 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1104 a) for 100mm dia pipe. 1105 b) for 75mm dia pipe. 1106 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1107 a) 100mm 1108 Sand cast iron S&S as per IS - 3989 1109 b) 75mm 1110 Sand cast iron S&S as per IS- 3989 1111 Providing and fixing plaincast iron S & S sanitary bend. 1112 a) 100mm 1113 Sand cast iron S&S as per IS - 1729 1114 b) 75mm 1115 Sand cast iron S&S as per IS - 3989 1116 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1117 a) 100x100x100mm 1118 b) 75x75x75mm 1119 Providing and fixingcast iron terminal guard. 1120 a) 100mm 1121 b) 75mm 1122 Providing & fixingcast iron coller. 1123 a)100 mm 1124 Sand cast iron S&S as per IS - 3989 1125 b)75mm dia. 1126 Sand cast iron S&S as per IS - 3989 1127 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1128 a) 100mm 1129 b) 75mm 1130 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1131 a) 100mm inlet & 75mm outlet. 1132 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1133 15 mm nominal outer dia Pipes 1134 20 mm nominal outer dia Pipes 1135 25 mm nominal outer dia Pipes 1136 32 mm nominal outer dia Pipes 1137 Providing and fixing brass stop cock of approved quality. 1138 15 mm nominal bore 1139 Providing and fixing gun metal gate valve with wheel of approved quality. 1140 a) 25mm dia nominal bore 1141 b) 32mm dia nominal bore 1142 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1143 a) 25mm. Nominal bore 1144 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1145 a) 15mm nominal bore 1146 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1147 a) 15mm nominal bore 1148 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1149 a) 15mm nominal bore 1150 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1151 a) 15mm nominal bore 1152 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1153 15mm nominal bore 1154 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1155 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1156 25mm nominal bore, weighing not less than 62 gms 1157 Cutting holes up to 30x30 cm in walls including making good the same: 1158 With common burnt clay F.P.S. (non modular) bricks 1159 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1160 Repair to Plaster and Plinth Protection 1161 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1162 Two or more coats on new work 1163 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1164 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1165 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1166 15mm cement plaster on rough side of single or half brick wall of mix 1167 1:6 (1 cement : 6 course sand) 1168 6mm cement plaster to ceiling of mix : 1169 1:3 ( 1 cement : 3 fine sand) 1170 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1171 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1172 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1173 Old work (one or more coats) 1174 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1175 Repairs to Door / Windows 1176 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1177 Of area 3 sq. metres and below 1178 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1179 Of area 3 sq. metres and below 1180 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1181 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1182 Renewal of old putty of glass panes (length) 1183 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 1184 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1185 250 mm weighing not less than 150gms. 1186 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1187 100X58X1.90 mm 1188 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1189 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1190 300 x 10mm 1191 150 x 10mm 1192 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1193 125 mm 1194 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1195 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1196 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1197 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1199 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1200 With 12 mm mild steel U beading 1201 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1202 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1203 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1204 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1205 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1206 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1207 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1208 4.0 mm thick glass panes 1209 Applying priming coat : 1210 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1211 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1212 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1213 Two or more coats on new work 1214 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1215 One or more coats on old work 1216 Repairs to Flooring 1217 Miscellaneous 1218 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1219 In cement mortar 1220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1221 Cement mortar 1:6 (1 cement : 6 coarse sand) 1222 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1223 Cement mortar 1:4 (1 cement :4 coarse sand 1224 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1225 ELECTRICAL WORK OF BOYS DORM - 24 CPWD ( 1 BLOCK) 1226 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1227 Group B 1228 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1229 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1230 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1231 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1232 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1233 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1234 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1235 Group B 1236 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1237 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1238 2 x 1.5 sq. mm 1239 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1240 25 mm 1241 32 mm 1242 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1243 100 mm X 100 mm X 60 mm deep 1244 150 mm X 75 mm X 60 mm deep 1245 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1246 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1247 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1248 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1249 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1250 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1251 4 way (4 + 12), Double door 1252 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1253 Single pole 1254 Single pole and neutral 1255 Triple pole 1256 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1257 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1258 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1259 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1260 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1261 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1262 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1263 Staff Qtrs Type-III . (12 nos. i.e. 3 blocks of four unit each) G+1 1264 Structural Repair & Retrofitting 1265 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1266 25 mm average thickness 1267 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1268 Bars upto 12 mm diameter 1269 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1270 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1271 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1272 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1273 Repairs to Roof 1274 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1275 In cement mortar 1276 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1277 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1278 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1279 Repair to Toilets 1280 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1281 For thickness of tiles 10 mm to 25 mm 1282 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1283 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1284 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1285 Providing and filling of cinder in sunken portions. 1286 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1287 75 to 80 mm dia pipe 1288 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1289 15 mm to 40 mm nominal bore 1290 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1291 Up to 150 mm diameter 1292 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1293 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1294 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1295 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1296 Up to 150 mm diameter 1297 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1298 Rectangular manhole 90x80 cm and 45 cm deep 1299 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1300 110 mm diameter 1301 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1302 a) Coupler 1303 110 mm 1304 b) Bend 87.5° 1305 110 mm bend 1306 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1307 75 mm diameter pipes 1308 100 mm diameter pipes 1309 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1310 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1311 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1312 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1313 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1314 Kitchen sink without drain board 1315 610x510 mm bowl depth 200 mm 1316 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1317 a) 32mm dia (for wash basin) 1318 b) 40mm dia (for sink and urinal) 1319 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1320 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1321 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1322 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1323 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1324 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1325 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1326 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1327 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1328 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1329 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1330 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1331 P-Trap type Floor Trap 110 x 75 mm 1332 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1333 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1334 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1335 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1336 Providing & fixing soil, waste and vent pipes. 1337 a) 100mm dia centrifugally cast iron S & S pipe. 1338 b)75mm dia centrifugally cast iron S & S pipe. 1339 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1340 a) for 100mm dia pipe. 1341 b) for 75mm dia pipe. 1342 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1343 a) 100mm 1344 Sand cast iron S&S as per IS - 3989 1345 b) 75mm 1346 Sand cast iron S&S as per IS- 3989 1347 Providing and fixing plaincast iron S & S sanitary bend. 1348 a) 100mm 1349 Sand cast iron S&S as per IS - 1729 1350 b) 75mm 1351 Sand cast iron S&S as per IS - 3989 1352 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1353 a) 100x100x100mm 1354 b) 75x75x75mm 1355 Providing and fixingcast iron terminal guard. 1356 a) 100mm 1357 b) 75mm 1358 Providing & fixingcast iron coller. 1359 a)100 mm 1360 Sand cast iron S&S as per IS - 3989 1361 b)75mm dia. 1362 Sand cast iron S&S as per IS - 3989 1363 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1364 a) 100mm 1365 b) 75mm 1366 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1367 a) 100mm inlet & 75mm outlet. 1368 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1369 15 mm nominal outer dia Pipes 1370 20 mm nominal outer dia Pipes 1371 25 mm nominal outer dia Pipes 1372 32 mm nominal outer dia Pipes 1373 Providing and fixing brass stop cock of approved quality. 1374 15 mm nominal bore 1375 Providing and fixing gun metal gate valve with wheel of approved quality. 1376 a) 25mm dia nominal bore 1377 b) 32mm dia nominal bore 1378 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1379 a) 25mm. Nominal bore 1380 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1381 a) 15mm nominal bore 1382 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1383 a) 15mm nominal bore 1384 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1385 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1386 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1387 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1388 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1389 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1390 a) 15mm nominal bore 1391 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1392 a) 15mm nominal bore 1393 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1394 a) 15mm nominal bore 1395 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1396 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1397 25mm nominal bore, weighing not less than 62 gms 1398 Cutting holes up to 30x30 cm in walls including making good the same: 1399 With common burnt clay F.P.S. (non modular) bricks 1400 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1401 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1402 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1403 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1404 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1405 Repair to Plaster and Plinth Protection 1406 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1407 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1408 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1409 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1410 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1411 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1412 With cement mortar 1:4 (1cement: 4 coarse sand) 1413 12mm cement plaster of mix : 1414 1:6 (1 cement : 6 course sand) 1415 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1416 Raised and cut pointing 1417 6mm cement plaster to ceiling of mix : 1418 1:3 ( 1 cement : 3 fine sand) 1419 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1420 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1421 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1422 Old work (one or more coats) 1423 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1424 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1425 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1426 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1427 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1428 Repairs to Door / Windows 1429 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1430 Of area 3 sq. metres and below 1431 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1432 Of area 3 sq. metres and below 1433 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1434 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1435 Renewal of old putty of glass panes (length) 1436 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1437 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1438 250 mm weighing not less than 150gms. 1439 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1440 100X58X1.90 mm 1441 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1442 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1443 300 x 10mm 1444 150 x 10mm 1445 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1446 125 mm 1447 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1448 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1449 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1450 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1451 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1452 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1453 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1454 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1455 4.0 mm thick glass panes 1456 Applying priming coat : 1457 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1458 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1459 Two or more coats on new work 1460 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1461 One or more coats on old work 1462 Miscellaneous 1463 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1464 Cement mortar 1:6 (1 cement : 6 coarse sand) 1465 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1466 Cement mortar 1:4 (1 cement :4 coarse sand 1467 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1468 ELECTRICAL WORK OF TYPE-III (G+1) 1469 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1470 Group B 1471 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1472 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1473 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1474 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1475 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1476 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1477 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1478 Group B 1479 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1480 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1481 2 x 1.5 sq. mm 1482 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1483 25 mm 1484 32 mm 1485 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1486 100 mm X 100 mm X 60 mm deep 1487 150 mm X 75 mm X 60 mm deep 1488 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1489 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1490 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1491 S/F light plug point Modular type accessories :- 1492 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1493 S/F power plug point modular type accessories :- 1494 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1495 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1496 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1497 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1498 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1499 6 way, Double door 1500 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1501 4 way (4 + 12), Double door 1502 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1503 Single pole 1504 Single pole and neutral 1505 Triple pole 1506 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1507 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1508 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1509 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1510 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1511 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1512 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1513 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1514 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1515 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1516 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1517 Type-II Staff Qtrs. (12 nos. i.e. 3 block of 4 unit each) G+1 1518 Structural Repair & Retrofitting 1519 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1520 25 mm average thickness 1521 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1522 Bars upto 12 mm diameter 1523 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1524 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1525 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1526 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1527 Repairs to Roof 1528 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1529 In cement mortar 1530 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1531 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1532 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1533 Repair to Toilets 1534 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1535 For thickness of tiles 10 mm to 25 mm 1536 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1537 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1538 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1539 Providing and filling of cinder in sunken portions. 1540 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1541 75 to 80 mm dia pipe 1542 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1543 15 mm to 40 mm nominal bore 1544 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1545 Up to 150 mm diameter 1546 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1547 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1548 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1549 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1550 Up to 150 mm diameter 1551 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1552 Rectangular manhole 90x80 cm and 45 cm deep 1553 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1554 110 mm diameter 1555 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1556 a) Coupler 1557 110 mm 1558 b) Bend 87.5° 1559 110 mm bend 1560 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1561 75 mm diameter pipes 1562 100 mm diameter pipes 1563 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1564 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1565 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1566 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1567 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1568 Kitchen sink without drain board 1569 610x510 mm bowl depth 200 mm 1570 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1571 a) 32mm dia (for wash basin) 1572 b) 40mm dia (for sink and urinal) 1573 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1574 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1575 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1576 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1577 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1578 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1579 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1580 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1581 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1582 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1583 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1584 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1585 P-Trap type Floor Trap 110 x 75 mm 1586 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1587 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1588 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1589 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1590 Providing & fixing soil, waste and vent pipes. 1591 a) 100mm dia centrifugally cast iron S & S pipe. 1592 b)75mm dia centrifugally cast iron S & S pipe. 1593 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1594 a) for 100mm dia pipe. 1595 b) for 75mm dia pipe. 1596 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1597 a) 100mm 1598 Sand cast iron S&S as per IS - 3989 1599 b) 75mm 1600 Sand cast iron S&S as per IS- 3989 1601 Providing and fixing plaincast iron S & S sanitary bend. 1602 a) 100mm 1603 Sand cast iron S&S as per IS - 1729 1604 b) 75mm 1605 Sand cast iron S&S as per IS - 3989 1606 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1607 a) 100x100x100mm 1608 b) 75x75x75mm 1609 Providing and fixingcast iron terminal guard. 1610 a) 100mm 1611 b) 75mm 1612 Providing & fixingcast iron coller. 1613 a)100 mm 1614 Sand cast iron S&S as per IS - 3989 1615 b)75mm dia. 1616 Sand cast iron S&S as per IS - 3989 1617 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1618 a) 100mm 1619 b) 75mm 1620 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1621 a) 100mm inlet & 75mm outlet. 1622 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1623 15 mm nominal outer dia Pipes 1624 20 mm nominal outer dia Pipes 1625 25 mm nominal outer dia Pipes 1626 32 mm nominal outer dia Pipes 1627 Providing and fixing brass stop cock of approved quality. 1628 15 mm nominal bore 1629 Providing and fixing gun metal gate valve with wheel of approved quality. 1630 a) 25mm dia nominal bore 1631 b) 32mm dia nominal bore 1632 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1633 a) 25mm. Nominal bore 1634 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1635 a) 15mm nominal bore 1636 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1637 a) 15mm nominal bore 1638 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1639 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1640 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1641 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1642 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1643 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1644 a) 15mm nominal bore 1645 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1646 a) 15mm nominal bore 1647 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1648 a) 15mm nominal bore 1649 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1650 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1651 25mm nominal bore, weighing not less than 62 gms 1652 Cutting holes up to 30x30 cm in walls including making good the same: 1653 With common burnt clay F.P.S. (non modular) bricks 1654 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1655 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1656 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1657 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1658 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1659 Repair to Plaster and Plinth Protection 1660 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1661 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1662 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1663 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1664 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1665 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1666 With cement mortar 1:4 (1cement: 4 coarse sand) 1667 15mm cement plaster of mix : 1668 1:6 (1 cement : 6 course sand) 1669 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1670 Raised and cut pointing 1671 6mm cement plaster to ceiling of mix : 1672 1:3 ( 1 cement : 3 fine sand) 1673 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1674 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1675 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1676 Old work (one or more coats) 1677 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1678 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1679 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1680 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1681 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1682 Repairs to Door / Windows 1683 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1684 Of area 3 sq. metres and below 1685 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1686 Of area 3 sq. metres and below 1687 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1688 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1689 Renewal of old putty of glass panes (length) 1690 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1691 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1692 250 mm weighing not less than 150gms. 1693 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1694 100X58X1.90 mm 1695 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1696 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1697 300 x 10mm 1698 150 x 10mm 1699 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1700 125 mm 1701 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1702 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1703 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1704 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1705 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1706 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1707 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1708 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1709 4.0 mm thick glass panes 1710 Applying priming coat : 1711 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1712 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1713 Two or more coats on new work 1714 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1715 One or more coats on old work 1716 Miscellaneous 1717 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1718 Cement mortar 1:6 (1 cement : 6 coarse sand) 1719 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1720 Cement mortar 1:4 (1 cement :4 coarse sand 1721 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1722 ELECTRICAL WORK 1723 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1724 Group B 1725 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1726 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1727 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1728 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1729 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1730 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1731 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1732 Group B 1733 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1734 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1735 2 x 1.5 sq. mm 1736 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1737 25 mm 1738 32 mm 1739 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1740 100 mm X 100 mm X 60 mm deep 1741 150 mm X 75 mm X 60 mm deep 1742 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1743 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1744 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1745 S/F light plug point Modular type accessories :- 1746 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1747 S/F power plug point modular type accessories :- 1748 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1749 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1750 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1751 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1752 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1753 6 way, Double door 1754 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1755 4 way (4 + 12), Double door 1756 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1757 Single pole 1758 Single pole and neutral 1759 Triple pole 1760 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1761 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1762 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1763 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1764 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1765 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1766 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1767 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1768 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1769 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1770 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1771 Type-I Staff Qtrs. (12 nos. i.e. 3 block of 4 units each ) G 1772 Structural Repair & Retrofitting 1773 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1774 25 mm average thickness 1775 50 mm average thickness 1776 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1777 Bars upto 12 mm diameter 1778 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1779 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1780 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1781 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1782 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1783 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1784 Repairs to Roof 1785 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1786 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1787 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1788 Repair to Toilets 1789 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1790 For thickness of tiles 10 mm to 25 mm 1791 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1792 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1793 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1794 75 to 80 mm dia pipe 1795 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1796 15 mm to 40 mm nominal bore 1797 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1798 Up to 150 mm diameter 1799 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1800 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1801 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1802 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1803 Up to 150 mm diameter 1804 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1805 Rectangular manhole 90x80 cm and 45 cm deep 1806 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1807 110 mm diameter 1808 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1809 a) Coupler 1810 110 mm 1811 b) Bend 87.5° 1812 110 mm bend 1813 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1814 75 mm diameter pipes 1815 100 mm diameter pipes 1816 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1817 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1818 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1819 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1820 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1821 Kitchen sink without drain board 1822 610x510 mm bowl depth 200 mm 1823 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1824 a) 32mm dia (for wash basin) 1825 b) 40mm dia (for sink and urinal) 1826 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1827 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1828 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1829 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1830 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1831 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1832 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1833 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1834 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1835 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1836 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1837 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1838 P-Trap type Floor Trap 110 x 75 mm 1839 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1840 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1841 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1842 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1843 Providing & fixing soil, waste and vent pipes. 1844 a) 100mm dia centrifugally cast iron S & S pipe. 1845 b)75mm dia centrifugally cast iron S & S pipe. 1846 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1847 a) for 100mm dia pipe. 1848 b) for 75mm dia pipe. 1849 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1850 a) 100mm 1851 Sand cast iron S&S as per IS - 3989 1852 b) 75mm 1853 Sand cast iron S&S as per IS- 3989 1854 Providing and fixing plaincast iron S & S sanitary bend. 1855 a) 100mm 1856 Sand cast iron S&S as per IS - 1729 1857 b) 75mm 1858 Sand cast iron S&S as per IS - 3989 1859 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1860 a) 100x100x100mm 1861 b) 75x75x75mm 1862 Providing and fixingcast iron terminal guard. 1863 a) 100mm 1864 b) 75mm 1865 Providing & fixingcast iron coller. 1866 a)100 mm 1867 Sand cast iron S&S as per IS - 3989 1868 b)75mm dia. 1869 Sand cast iron S&S as per IS - 3989 1870 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1871 a) 100mm 1872 b) 75mm 1873 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1874 a) 100mm inlet & 75mm outlet. 1875 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1876 15 mm nominal outer dia Pipes 1877 20 mm nominal outer dia Pipes 1878 25 mm nominal outer dia Pipes 1879 32 mm nominal outer dia Pipes 1880 Providing and fixing brass stop cock of approved quality. 1881 15 mm nominal bore 1882 Providing and fixing gun metal gate valve with wheel of approved quality. 1883 a) 25mm dia nominal bore 1884 b) 32mm dia nominal bore 1885 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1886 a) 25mm. Nominal bore 1887 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1888 a) 15mm nominal bore 1889 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1890 a) 15mm nominal bore 1891 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1892 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1893 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1894 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1895 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1896 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1897 a) 15mm nominal bore 1898 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1899 a) 15mm nominal bore 1900 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1901 a) 15mm nominal bore 1902 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1903 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1904 25mm nominal bore, weighing not less than 62 gms 1905 Cutting holes up to 30x30 cm in walls including making good the same: 1906 With common burnt clay F.P.S. (non modular) bricks 1907 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1908 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1909 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1910 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1911 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1912 Repair to Plaster and Plinth Protection 1913 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1914 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1915 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1916 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1917 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1918 With cement mortar 1:4 (1cement: 4 coarse sand) 1919 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1920 15mm cement plaster on rough side of single or half brick wall of mix 1921 1:6 (1 cement : 6 course sand) 1922 6mm cement plaster to ceiling of mix : 1923 1:3 ( 1 cement : 3 fine sand) 1924 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1925 Raised and cut pointing 1926 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1927 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1928 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1929 Old work (one or more coats) 1930 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1931 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1932 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1933 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1934 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1935 Repairs to Door / Windows 1936 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1937 Of area 3 sq. metres and below 1938 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1939 Of area 3 sq. metres and below 1940 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1941 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1942 Renewal of old putty of glass panes (length) 1943 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1944 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1945 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1946 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1947 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1948 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1949 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 1950 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc, complete. 1951 300 mm weighing not less than 200gms. 1952 250 mm weighing not less than 150gms. 1953 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1954 100X58X1.90 mm 1955 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1956 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1957 300 x 10mm 1958 150 x 10mm 1959 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1960 125 mm 1961 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1962 Twin rubber stopper 1963 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1964 30 mm thick shutterswith ISI marked M.S. butt hinges with necessary screws 1965 With ISI marked stainless steel butt hinges of required size 1966 Kiln seasoned and chemically treated hollock wood 1967 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1968 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1969 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1970 4.0 mm thick glass panes 1971 Applying priming coat : 1972 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1973 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1974 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1975 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 1976 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1977 One or more coats on old work 1978 Miscellaneous 1979 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1980 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 1981 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 1982 Edges of slabs and breaks in floors and walls 1983 Under 20 cm wide 1984 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 1985 Suspended floors, roofs, landings, balconies and access platform. 1986 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1987 Thermo-Mechanically Treated bars of grade Fe-500D or more. 1988 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1989 Cement mortar 1:6 (1 cement : 6 coarse sand) 1990 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1991 Cement mortar 1:4 (1 cement :4 coarse sand 1992 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1993 ELECTRICAL WORK 1994 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1995 Group B 1996 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1997 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1998 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1999 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 2000 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2001 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 2002 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2003 Group B 2004 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 2005 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2006 2 x 1.5 sq. mm 2007 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2008 25 mm 2009 32 mm 2010 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2011 100 mm X 100 mm X 60 mm deep 2012 150 mm X 75 mm X 60 mm deep 2013 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2014 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 2015 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2016 S/F light plug point Modular type accessories :- 2017 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2018 S/F power plug point modular type accessories :- 2019 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2020 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2021 Supplying and fixing brass batten/ angle holder including connection etc. as required. 2022 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2023 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2024 6 way, Double door 2025 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2026 4 way (4 + 12), Double door 2027 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2028 Single pole 2029 Single pole and neutral 2030 Triple pole 2031 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 2032 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2033 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2034 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 2035 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 2036 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 2037 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 2038 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 2039 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 2040 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 2041 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 2042 WATER SUPPLY 2043 DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY 2044 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 2045 External work 2046 20 mm dia nominal bore 2047 25 mm dia nominal bore 2048 32 mm dia nominal bore 2049 40 mm dia nominal bore 2050 50 mm dia nominal bore 2051 65 mm dia nominal bore 2052 80 mm dia nominal bore 2053 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 2054 20 mm diameter pipe 2055 25 mm diameter pipe 2056 32 mm diameter pipe 2057 40 mm diameter pipe 2058 50 mm diameter pipe 2059 65 mm diameter pipe 2060 80 mm diameter pipe 2061 Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work. 2062 20mm dia nominal bore 2063 25mm dia nominal bore 2064 32mm dia nominal bore 2065 40mm dia nominal bore 2066 50 mm diameter pipe 2067 65 mm diameter pipe 2068 80 mm diameter pipe 2069 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 2070 50 mm dia 2071 80 mm dia 2072 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2073 20 mm nominal bore 2074 25 mm nominal bore 2075 32 mm nominal bore 2076 40 mm nominal bore 2077 50 mm nominal bore 2078 65 mm nominal bore 2079 80 mm nominal bore 2080 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2081 Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work) 2082 25 mm nominal bore 2083 32 mm nominal bore 2084 40 mm nominal bore 2085 50 mm nominal bore 2086 65 mm nominal bore 2087 80 mm nominal bore 2088 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2089 LD- 2.5 2090 Rectangular shape 600*450 mm internal dimensions 2091 Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2092 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 2093 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2094 with common burnt clay F.P.S.(non module) brick of class designation 7.5 2095 BOREWELL 380 MTR DEPTH 2096 Sub Head : I Tubewells 2097 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different trata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 2098 All Type of Soil 2099 400mm dia 2100 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 2101 All Type of Soil 2102 400mm dia 2103 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 2104 200 mm nominal size dia having minimum wall thickness5.40 mm 2105 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 2106 200 mm nominal size dia 2107 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge. 2108 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 2109 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 2110 200 mm dia 2111 Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 2112 200 mm clamp 2113 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 2114 200 mm nominal size dia 2115 Supply, installation testing & commissioning of borewell submersible pumping set suitable to operate on 415 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 200 mm outer dia uPVC Pipe as per IS : 12818with fittings, clamps etc. complete in all respect as per details given below : 2116 Pump Motor shall be Class F Insulation , Pump and Motor shall be IP : 68 Protection Rating , and Motor Efficiency shall be Class IE-3 Efficiency . 2117 Pump to be lowered below groundas site Boring/drilling 2118 Pump capacity : 15000 litres/hr 2119 Head : 250M 2120 H.P : 15 ( Approx) 2121 Totalof one set Tubewell 2122 Provding and fixing heavy duty 65mm G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above with reducers, tees, flanges, elbow, crosses, union etc. and fixing the pipes onwall / ceiling / beam / floor including Clamping/Supporting the same, including painting with 2 coats of synthetic enamel paint as per the site requirement and shall be duly painted with two coats of approved quality synthetic enamel paint & shade over a readymix primer coat complete as required & as per directions of the engineer-in-charge for the following sizes: 2123 PANEL(Outdoor Type weather proof, double door with canopy and suitable MS Structure stand duly painted) 2124 INCOMER 2125 1 No.100 Amp FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 2126 Metering & Indication 2127 1 set of RYB phase indicating lamps 2128 MFM with Communication Facility along with control SP MCB 2129 Surge protection device , Type 2, MOV type for 8/20 us wave, 3 Nos phase to neutral, one No neutral to earth ,(minimum 3+1 mode) with minimum discharge capacity 40KA along with necessary fuses. 2130 BUS-BAR 2131 1 Set of 125A TPN Aluminium Bus Bar with colour coded PVC Sleeves 2132 OUTGOINGS 2133 3 Nos. 40A TPN MCB 2134 3 Nos. 25A DP MCB 2135 3 Nos. 20A DP MCB 2136 Plumbing Panel 2137 NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays 2138 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 2139 COST OF BORELOGING WORK (Bore logging is the process of recording detailed geological information from boreholes drilled during subsurface investigations. The primary aim is to understand the geological formations, stratigraphy, and hydrological conditions.) 2140 COST OF WATER QUALITY TEST ( Water quality testing involves analyzing water samples to determine their physical, chemical, and biological characteristics. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
25.
Housing Urban and Rular Development #9481158 Technical Bid
Tender For Special Repair Work At Jnv Sheikhpura (Bihar) - SCHOOL BUILDING 2 Structural Repair & Retrofitting 3 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 4 50mm average thickness 5 25 mm average thickness 6 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 7 Bars upto 12 mm diameter 8 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 9 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 10 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 12 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 13 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 14 Expansion Joint Treatment 15 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 16 Floor Joint of 100 mm gap 17 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 18 Wall Joint of 100 mm gap 19 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 20 Roof Joint of 100 mm gap 21 Repairs to Roof 22 Repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (Dr. Fixit Make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement: 4 coarse sand) 23 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 24 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 25 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 26 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 27 Asbestos Cement sheet 28 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 29 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* 30 Repair to Toilets + Plumbing Works 31 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 32 For thickness of tiles 10 mm to 25 mm 33 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 34 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 36 Providing and filling of cinder in sunken portion. 37 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 38 75 to 80 mm dia pipe 39 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 40 15 mm to 40 mm nominal bore 41 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 42 Up to 150 mm diameter 43 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 44 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 45 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 46 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 47 Rectangular manhole 90x80 cm and 45 cm deep 48 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 49 110 mm diameter 50 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 51 a) Coupler 52 110 mm 53 b) Bend 87.5° 54 110 mm bend 55 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 56 75 mm diameter pipes 57 100 mm diameter pipes 58 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 59 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 60 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 61 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 62 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 63 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 64 a) 32mm dia (for wash basin) 65 b) 40mm dia (for sink and urinal) 66 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 67 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 68 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 69 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 70 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 71 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 72 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 73 P-Trap type Floor Trap 110 x 75 mm 74 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 75 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 76 Providing and fixing 100 mm sand cast Iron grating for gully trap. 77 Providing & fixing soil, waste and vent pipes. 78 a) 100mm dia centrifugally cast iron S & S pipe. 79 b)75mm dia centrifugally cast iron S & S pipe. 80 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 81 a) for 100mm dia pipe. 82 b) for 75mm dia pipe. 83 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 84 a) 100mm 85 Sand cast iron S&S as per IS - 3989 86 b) 75mm 87 Sand cast iron S&S as per IS- 3989 88 Providing and fixing plaincast iron S & S sanitary bend. 89 a) 100mm 90 Sand cast iron S&S as per IS - 1729 91 b) 75mm 92 Sand cast iron S&S as per IS - 3989 93 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 94 a) 100x100x100mm 95 b) 75x75x75mm 96 Providing and fixingcast iron terminal guard. 97 a) 100mm 98 b) 75mm 99 Providing & fixingcast iron coller. 100 a)100 mm 101 Sand cast iron S&S as per IS - 3989 102 b)75mm dia. 103 Sand cast iron S&S as per IS - 3989 104 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 105 a) 100mm 106 b) 75mm 107 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 108 a) 100mm inlet & 75mm outlet. 109 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 110 Providing and fixing PTMT urinal cock of approved quality and colour. 111 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 112 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 113 15 mm nominal outer dia Pipes 114 20 mm nominal outer dia Pipes 115 25 mm nominal outer dia Pipes 116 32 mm nominal outer dia Pipes 117 Providing and fixing brass stop cock of approved quality. 118 15 mm nominal bore 119 Providing and fixing gun metal gate valve with wheel of approved quality. 120 a) 25mm dia nominal bore 121 b) 32mm dia nominal bore 122 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 123 a) 25mm. Nominal bore 124 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 125 a) 15mm nominal bore 126 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 127 a) 15mm nominal bore 128 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 129 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 130 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 131 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 132 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 133 a) 15mm nominal bore 134 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 135 a) 15mm nominal bore 136 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 137 15mm nominal bore 138 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 139 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 140 25mm nominal bore, weighing not less than 62 gms 141 Cutting holes up to 30x30 cm in walls including making good the same: 142 With common burnt clay F.P.S. (non modular) bricks 143 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 144 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 145 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 146 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 147 Repair to Plaster and Plinth Protection 148 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 149 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 150 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 151 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 152 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 153 With cement mortar 1:4 (1cement: 4 coarse sand) 154 12mm cement plaster of mix : 155 1:6 (1 cement : 6 course sand) 156 6mm cement plaster to ceiling of mix : 157 1:3 ( 1 cement : 3 fine sand) 158 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 159 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 160 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 161 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 162 Old work (one or more coats) 163 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 164 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 165 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 166 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 167 Repairs to Door / Windows 168 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 169 Of area 3 sq. metres and below 170 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 171 Of area 3 sq. metres and below 172 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 173 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 174 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 175 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 176 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 177 Fixed to steel windows by welding 178 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 179 300 mm weighing not less than 200gms. 180 250 mm weighing not less than 150gms. 181 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 182 100X58X1.90 mm 183 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 184 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 185 300 x 10mm 186 200 x 10mm 187 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 188 125 mm 189 Providing and fixing factory made PVC Door shutter made of solid foam PVC profiles of thickness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top / bottom / lock) rails of minimum cross section of 70mm x 28mm, of shape and design as per manufacturers specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with G.l. C section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturers specifications Mitered cut joints for styles and rails provided with telescopic polymeric L corners are joined together using solvent adhesive and strengthened with fully threaded stainless steel screws (of required size) through reinforcement stiffener with paneling of specified solid foam PVC board / high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded headings of required size using PVC solvent adhesive / cement. The finished door shutter including SS hardware, 1 no. SS sliding door bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10mm and 2 nos. SS handles 125 mm, shall be fixed to frame with 3 Nos. stainless steel hinges of minimum size 100x58x1.9mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge.(Cost of above hardware is inclusive in rates) 5 mm thick solid foam PVC panel of required size with moulded/extruded beading of appropriate design shape and size as per manufacturers specifications (to secure the panel insert tight in place within the style and rails of the shutter)matching the color &shade of shutter frame - Non decorative type. 190 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 191 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 192 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 193 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 194 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm 195 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 196 4.0 mm thick glass panes 197 Applying priming coat : 198 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 199 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 200 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 201 Two or more coats on new work 202 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 203 One or more coats on old work 204 Repairs to Flooring 205 Miscellaneous 206 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 207 In cement mortar 208 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 209 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 210 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 211 Edges of slabs and breaks in floors and walls 212 Under 20 cm wide 213 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 214 Suspended floors, roofs, landings, balconies and access platform. 215 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 216 Thermo-Mechanically Treated bars of grade Fe-500D or more. 217 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 218 Cement mortar 1:6 (1 cement : 6 coarse sand) 219 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 220 Cement mortar 1:4 (1 cement :4 coarse sand 221 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 222 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 223 Electrical Works 224 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 225 Group C 226 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 227 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 228 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 229 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 230 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 231 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 232 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 Group C 234 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 235 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 x 1.5 sq. mm 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm X 100 mm X 60 mm deep 242 150 mm X 75 mm X 60 mm deep 243 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 244 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 245 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 246 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 247 Supplying and fixing brass batten/ angle holder including connection etc. as required. 248 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 249 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 250 6 way, Double door 251 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 252 4 way (4 + 12), Double door 253 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 254 Single pole 255 Single pole and neutral 256 Triple pole 257 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 258 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 259 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 260 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 261 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 262 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 263 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 264 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 265 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 266 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 267 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 268 Upto 450 mm sweep 269 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 270 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 271 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 272 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 273 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 274 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 275 450 mm sweep 1400 rpm 276 LIGHTNING CONDUCTOR 277 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 278 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 279 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 280 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 281 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 282 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 283 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 284 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 285 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 286 MP HALL 287 Structural Repair & Retrofitting 288 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 289 50 mm average thickness 290 25 mm average thickness 291 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 292 Bars upto 12 mm diameter 293 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 294 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 295 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 296 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 297 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 298 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 299 Repairs to Roof 300 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 301 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 302 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 303 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 304 Asbestos Cement sheet 305 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 306 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 307 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* 308 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 309 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 310 Repair to Plaster and Plinth Protection 311 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 312 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 313 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 314 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 315 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 316 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 317 With cement mortar 1:4 (1cement: 4 coarse sand) 318 12mm cement plaster of mix : 319 1:6 (1 cement : 6 course sand) 320 6mm cement plaster to ceiling of mix : 321 1:3 ( 1 cement : 3 fine sand) 322 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 323 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 324 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 325 Old work (one or more coats) 326 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 327 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 328 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 329 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 330 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 331 Repairs to Door / Windows 332 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 333 Of area 3 sq. metres and below 334 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 335 Of area 3 sq. metres and below 336 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 337 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 338 Renewal of old putty of glass panes (length) 339 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 340 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 341 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 342 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 343 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 344 300 mm weighing not less than 200gms. 345 250 mm weighing not less than 150gms. 346 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 347 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 348 300 x 10mm 349 150 x 10mm 350 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 351 With 12 mm mild steel U beading 352 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 353 125 mm 354 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 355 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 356 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 357 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 358 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 359 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 360 4.0 mm thick glass panes 361 Applying priming coat : 362 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 363 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 364 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 365 Two or more coats on new work 366 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 367 One or more coats on old work 368 Miscellaneous 369 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 370 In cement mortar 371 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 372 Cement mortar 1:6 (1 cement : 6 coarse sand) 373 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 374 Cement mortar 1:4 (1 cement :4 coarse sand 375 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 376 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 377 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 378 75 to 80 mm dia pipe 379 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 380 110 mm diameter 381 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 382 a) Coupler 383 110 mm 384 b) Bend 87.5° 385 110 mm bend 386 ELECTRICAL WORK 387 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 388 Group C 389 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 390 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 391 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 392 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 393 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 394 2 x 1.5 sq. mm 395 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 396 25 mm 397 32 mm 398 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 399 100 mm X 100 mm X 60 mm deep 400 150 mm X 75 mm X 60 mm deep 401 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 402 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 403 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 404 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 405 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 406 6 way, Double door 407 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 408 4 way (4 + 12), Double door 409 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 410 Single pole 411 Single pole and neutral 412 Triple pole 413 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 414 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 415 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 416 Upto 450 mm sweep 417 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 418 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 419 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 420 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 421 Supply of 30W LED recess mounted fixtureMAKE-PHILIPS CAT NO.RC380B LED30S-6500 L60W60 PSD OD S1 or equivalent. 422 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 423 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 424 450 mm sweep 1400 rpm 425 KITCHEN & DINNING 426 Structural Repair & Retrofitting 427 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 428 50mm average thickness 429 25 mm average thickness 430 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 431 Bars upto 12 mm diameter 432 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 433 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 434 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 435 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 436 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 437 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 438 Repairs to Roof 439 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 440 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 441 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 442 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 443 Asbestos Cement sheet 444 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 445 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 446 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* 447 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes. 448 Repair to Toilets + Plumbing Works 449 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 450 For thickness of tiles 10 mm to 25 mm 451 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 452 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 453 PLUMBING WORK 454 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 455 75 to 80 mm dia pipe 456 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 457 15 mm to 40 mm nominal bore 458 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 459 Up to 150 mm diameter 460 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 461 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 462 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 463 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 464 Rectangular manhole 90x80 cm and 45 cm deep 465 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 466 110 mm diameter 467 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 468 a) Coupler 469 110 mm 470 b) Bend 87.5° 471 110 mm bend 472 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 473 75 mm diameter pipes 474 100 mm diameter pipes 475 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 476 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 477 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm. 478 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 479 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 480 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 481 a) 32mm dia (for wash basin) 482 b) 40mm dia (for sink and urinal) 483 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 484 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 485 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 486 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 487 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 488 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 489 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 490 P-Trap type Floor Trap 110 x 75 mm 491 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 492 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 493 Providing and fixing 100 mm sand cast Iron grating for gully trap. 494 Providing & fixing soil, waste and vent pipes. 495 a) 100mm dia centrifugally cast iron S & S pipe. 496 b)75mm dia centrifugally cast iron S & S pipe. 497 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 498 a) for 100mm dia pipe. 499 b) for 75mm dia pipe. 500 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 501 a) 100mm 502 Sand cast iron S&S as per IS - 3989 503 b) 75mm 504 Sand cast iron S&S as per IS- 3989 505 Providing and fixing plaincast iron S & S sanitary bend. 506 a) 100mm 507 Sand cast iron S&S as per IS - 1729 508 b) 75mm 509 Sand cast iron S&S as per IS - 3989 510 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 511 a) 100x100x100mm 512 b) 75x75x75mm 513 Providing and fixingcast iron terminal guard. 514 a) 100mm 515 b) 75mm 516 Providing & fixingcast iron coller. 517 a)100 mm 518 Sand cast iron S&S as per IS - 3989 519 b)75mm dia. 520 Sand cast iron S&S as per IS - 3989 521 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 522 a) 100mm 523 b) 75mm 524 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 525 a) 100mm inlet & 75mm outlet. 526 Providing and fixing PTMT urinal cock of approved quality and colour. 527 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 528 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 529 15 mm nominal outer dia Pipes 530 20 mm nominal outer dia Pipes 531 25 mm nominal outer dia Pipes 532 32 mm nominal outer dia Pipes 533 Providing and fixing brass stop cock of approved quality. 534 15 mm nominal bore 535 Providing and fixing gun metal gate valve with wheel of approved quality. 536 a) 25mm dia nominal bore 537 b) 32mm dia nominal bore 538 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 539 a) 25mm. Nominal bore 540 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 541 a) 15mm nominal bore 542 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 543 a) 15mm nominal bore 544 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 545 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 546 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 547 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 548 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 549 a) 15mm nominal bore 550 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 551 a) 15mm nominal bore 552 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 553 15mm nominal bore 554 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 555 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 556 25mm nominal bore, weighing not less than 62 gms 557 Cutting holes up to 30x30 cm in walls including making good the same: 558 With common burnt clay F.P.S. (non modular) bricks 559 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 560 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 561 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 562 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 563 Repair to Plaster and Plinth Protection 564 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 565 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 566 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 567 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 568 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 569 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 570 With cement mortar 1:4 (1cement: 4 coarse sand) 571 12mm cement plaster of mix : 572 1:6 (1 cement : 6 course sand) 573 6mm cement plaster to ceiling of mix : 574 1:3 ( 1 cement : 3 fine sand) 575 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 576 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 577 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 578 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 579 Old work (one or more coats) 580 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 581 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 582 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 583 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 584 Repairs to Door / Windows 585 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 586 Of area 3 sq. metres and below 587 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 588 Of area 3 sq. metres and below 589 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 590 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 591 Renewal of old putty of glass panes (length) 592 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 593 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 594 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 595 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 596 300 mm weighing not less than 200gms. 597 250 mm weighing not less than 150gms. 598 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 599 100X58X1.90 mm 600 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 601 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 602 300 x 10mm 603 200 x 10mm 604 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 605 125 mm 606 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 607 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) /Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 608 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 609 With 12 mm mild steel U beading 610 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 611 Using flats 30x6mm for diagonal braces and central cross piece 612 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 613 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 614 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size). 615 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 616 4.0 mm thick glass panes 617 Applying priming coat : 618 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 619 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 620 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 621 Two or more coats on new work 622 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 623 One or more coats on old work 624 Miscellaneous 625 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 626 In cement mortar 627 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 628 Cement mortar 1:6 (1 cement : 6 coarse sand) 629 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : 630 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 631 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 632 Edges of slabs and breaks in floors and walls 633 Under 20 cm wide 634 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 635 Suspended floors, roofs, landings, balconies and access platform. 636 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 637 Thermo-Mechanically Treated bars of grade Fe-500D or more. 638 ELECTRICAL 639 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 640 Group C 641 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 642 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 643 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 644 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 645 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 646 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 647 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 648 Group C 649 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 650 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 651 2 x 1.5 sq. mm 652 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 653 25 mm 654 32 mm 655 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 656 100 mm X 100 mm X 60 mm deep 657 150 mm X 75 mm X 60 mm deep 658 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 659 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 660 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 661 Supplying and fixing brass batten/ angle holder including connection etc. as required. 662 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 663 4 way (4 + 12), Double door 664 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 665 Single pole 666 Single pole and neutral 667 Triple pole 668 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 669 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 670 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 671 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 672 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 673 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 674 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 675 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 676 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 677 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 678 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 679 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 680 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 681 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 682 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 683 450 mm sweep 1400 rpm 684 Boys Dormitories(CBRI Type) - 4 Blocks 685 Structural Repair & Retrofitting 686 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 687 50mm average thickness 688 25 mm average thickness 689 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 690 Bars upto 12 mm diameter 691 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 692 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 693 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 694 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 695 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 696 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 697 Repairs to Roof 698 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 699 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 700 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 701 Repair to Toilets 702 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 703 For thickness of tiles 10 mm to 25 mm 704 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 705 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 706 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 707 Providing and filling of cinder in sunken portions. 708 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 709 75 to 80 mm dia pipe 710 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 711 15 mm to 40 mm nominal bore 712 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 713 Up to 150 mm diameter 714 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 715 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 716 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 717 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 718 Up to 150 mm diameter 719 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 720 Rectangular manhole 90x80 cm and 45 cm deep 721 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 722 110 mm diameter 723 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 724 a) Coupler 725 110 mm 726 b) Bend 87.5° 727 110 mm bend 728 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 729 75 mm diameter pipes 730 100 mm diameter pipes 731 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 732 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 733 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 734 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 735 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 736 a) 32mm dia (for wash basin) 737 b) 40mm dia (for sink and urinal) 738 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 739 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 740 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 741 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 742 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 743 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 744 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 745 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 746 P-Trap type Floor Trap 110 x 75 mm 747 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 748 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 749 Providing and fixing 100 mm sand cast Iron grating for gully trap. 750 Providing & fixing soil, waste and vent pipes. 751 a) 100mm dia centrifugally cast iron S & S pipe. 752 b)75mm dia centrifugally cast iron S & S pipe. 753 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 754 a) for 100mm dia pipe. 755 b) for 75mm dia pipe. 756 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 757 a) 100mm 758 Sand cast iron S&S as per IS - 3989 759 b) 75mm 760 Sand cast iron S&S as per IS- 3989 761 Providing and fixing plaincast iron S & S sanitary bend. 762 a) 100mm 763 Sand cast iron S&S as per IS - 1729 764 b) 75mm 765 Sand cast iron S&S as per IS - 3989 766 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 767 a) 100x100x100mm 768 b) 75x75x75mm 769 Providing and fixingcast iron terminal guard. 770 a) 100mm 771 b) 75mm 772 Providing & fixingcast iron coller. 773 a)100 mm 774 Sand cast iron S&S as per IS - 3989 775 b)75mm dia. 776 Sand cast iron S&S as per IS - 3989 777 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 778 a) 100mm 779 b) 75mm 780 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 781 a) 100mm inlet & 75mm outlet. 782 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 783 15 mm nominal outer dia Pipes 784 20 mm nominal outer dia Pipes 785 25 mm nominal outer dia Pipes 786 32 mm nominal outer dia Pipes 787 Providing and fixing brass stop cock of approved quality. 788 15 mm nominal bore 789 Providing and fixing gun metal gate valve with wheel of approved quality. 790 a) 25mm dia nominal bore 791 b) 32mm dia nominal bore 792 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 793 a) 25mm. Nominal bore 794 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 795 a) 15mm nominal bore 796 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 797 a) 15mm nominal bore 798 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 799 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 800 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 801 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 802 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 803 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 804 a) 15mm nominal bore 805 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 806 a) 15mm nominal bore 807 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 808 15mm nominal bore 809 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 810 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 811 25mm nominal bore, weighing not less than 62 gms 812 Cutting holes up to 30x30 cm in walls including making good the same: 813 With common burnt clay F.P.S. (non modular) bricks 814 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 815 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 816 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 817 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 818 Repair to Plaster and Plinth Protection 819 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 820 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 821 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 822 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 823 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 824 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 825 With cement mortar 1:4 (1cement: 4 coarse sand) 826 12mm cement plaster of mix : 827 1:6 (1 cement : 6 course sand) 828 6mm cement plaster to ceiling of mix : 829 1:3 ( 1 cement : 3 fine sand) 830 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 831 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 832 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 833 Old work (one or more coats) 834 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 835 Repairs to Door / Windows 836 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 837 Of area 3 sq. metres and below 838 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 839 Of area 3 sq. metres and below 840 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 841 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 842 Renewal of old putty of glass panes (length) 843 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 844 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 845 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 846 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 847 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 848 125 X 64 X 1.90 MM 849 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 850 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 851 With 12 mm mild steel U beading 852 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 853 300 mm weighing not less than 200gms. 854 250 mm weighing not less than 150gms. 855 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 856 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 857 300 x 10mm 858 150 x 10mm 859 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 860 125 mm 861 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 862 Using flats 30x6mm for diagonal braces and central cross piece 863 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 864 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 865 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqm 866 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 867 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 868 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 869 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 870 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 871 4.0 mm thick glass panes 872 Applying priming coat : 873 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 874 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 875 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 876 Two or more coats on new work 877 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 878 One or more coats on old work 879 Miscellaneous 880 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 881 In cement mortar 882 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 883 Cement mortar 1:6 (1 cement : 6 coarse sand) 884 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 885 Cement mortar 1:4 (1 cement :4 coarse sand 886 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 887 ELECTRICAL WORK OF BOYS DORMITORY 888 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 889 Group B 890 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 891 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 892 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 893 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 894 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 895 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 896 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 897 Group B 898 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 899 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 900 2 x 1.5 sq. mm 901 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 902 25 mm 903 32 mm 904 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 905 100 mm X 100 mm X 60 mm deep 906 150 mm X 75 mm X 60 mm deep 907 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 908 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 909 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 910 Supplying and fixing brass batten/ angle holder including connection etc. as required. 911 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 912 4 way (4 + 12), Double door 913 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 914 Single pole 915 Single pole and neutral 916 Triple pole 917 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 918 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 919 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 920 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 921 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 922 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 923 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 924 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 925 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 926 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 927 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 928 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 929 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 930 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 931 Upto 450 mm sweep 932 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 933 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 934 450 mm sweep 1400 rpm 935 Girls Dormitories(CBRI Type) - 2 Blocks 936 Structural Repair & Retrofitting 937 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 938 50mm average thickness 939 25 mm average thickness 940 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 941 Bars upto 12 mm diameter 942 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 943 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 944 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 945 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 946 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 947 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 948 Repairs to Roof 949 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 950 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 951 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 952 Repair to Toilets 953 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 954 For thickness of tiles 10 mm to 25 mm 955 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 956 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 957 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 958 Providing and filling of cinder in sunken portions. 959 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 960 75 to 80 mm dia pipe 961 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 962 15 mm to 40 mm nominal bore 963 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 964 Up to 150 mm diameter 965 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 966 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 967 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 968 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 969 Up to 150 mm diameter 970 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 971 Rectangular manhole 90x80 cm and 45 cm deep 972 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 973 110 mm diameter 974 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 975 a) Coupler 976 110 mm 977 b) Bend 87.5° 978 110 mm bend 979 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 980 75 mm diameter pipes 981 100 mm diameter pipes 982 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 983 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 984 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 985 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 986 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 987 a) 32mm dia (for wash basin) 988 b) 40mm dia (for sink and urinal) 989 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 990 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 991 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 992 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 993 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 994 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 995 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 996 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 997 P-Trap type Floor Trap 110 x 75 mm 998 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 999 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1000 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1001 Providing & fixing soil, waste and vent pipes. 1002 a) 100mm dia centrifugally cast iron S & S pipe. 1003 b)75mm dia centrifugally cast iron S & S pipe. 1004 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1005 a) for 100mm dia pipe. 1006 b) for 75mm dia pipe. 1007 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1008 a) 100mm 1009 Sand cast iron S&S as per IS - 3989 1010 b) 75mm 1011 Sand cast iron S&S as per IS- 3989 1012 Providing and fixing plaincast iron S & S sanitary bend. 1013 a) 100mm 1014 Sand cast iron S&S as per IS - 1729 1015 b) 75mm 1016 Sand cast iron S&S as per IS - 3989 1017 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1018 a) 100x100x100mm 1019 b) 75x75x75mm 1020 Providing and fixingcast iron terminal guard. 1021 a) 100mm 1022 b) 75mm 1023 Providing & fixingcast iron coller. 1024 a)100 mm 1025 Sand cast iron S&S as per IS - 3989 1026 b)75mm dia. 1027 Sand cast iron S&S as per IS - 3989 1028 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1029 a) 100mm 1030 b) 75mm 1031 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1032 a) 100mm inlet & 75mm outlet. 1033 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1034 15 mm nominal outer dia Pipes 1035 20 mm nominal outer dia Pipes 1036 25 mm nominal outer dia Pipes 1037 32 mm nominal outer dia Pipes 1038 Providing and fixing brass stop cock of approved quality. 1039 15 mm nominal bore 1040 Providing and fixing gun metal gate valve with wheel of approved quality. 1041 a) 25mm dia nominal bore 1042 b) 32mm dia nominal bore 1043 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1044 a) 25mm. Nominal bore 1045 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1046 a) 15mm nominal bore 1047 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1048 a) 15mm nominal bore 1049 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1050 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1051 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1052 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1053 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1054 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1055 a) 15mm nominal bore 1056 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1057 a) 15mm nominal bore 1058 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1059 15mm nominal bore 1060 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1061 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1062 25mm nominal bore, weighing not less than 62 gms 1063 Cutting holes up to 30x30 cm in walls including making good the same: 1064 With common burnt clay F.P.S. (non modular) bricks 1065 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1066 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1067 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1068 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1069 Repair to Plaster and Plinth Protection 1070 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1071 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1072 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1073 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1074 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1075 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1076 With cement mortar 1:4 (1cement: 4 coarse sand) 1077 12mm cement plaster of mix : 1078 1:6 (1 cement : 6 course sand) 1079 6mm cement plaster to ceiling of mix : 1080 1:3 ( 1 cement : 3 fine sand) 1081 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1082 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1083 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1084 Old work (one or more coats) 1085 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1086 Repairs to Door / Windows 1087 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1088 Of area 3 sq. metres and below 1089 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1090 Of area 3 sq. metres and below 1091 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1092 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1093 Renewal of old putty of glass panes (length) 1094 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1095 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1096 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1097 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 1098 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1099 125 X 64 X 1.90 MM 1100 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 1101 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1102 With 12 mm mild steel U beading 1103 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1104 300 mm weighing not less than 200gms. 1105 250 mm weighing not less than 150gms. 1106 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1107 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1108 300 x 10mm 1109 150 x 10mm 1110 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1111 125 mm 1112 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1113 Using flats 30x6mm for diagonal braces and central cross piece 1114 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1115 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1116 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqm 1117 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1118 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1119 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1120 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1121 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1122 4.0 mm thick glass panes 1123 Applying priming coat : 1124 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1125 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1126 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1127 Two or more coats on new work 1128 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1129 One or more coats on old work 1130 Miscellaneous 1131 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1132 In cement mortar 1133 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1134 Cement mortar 1:6 (1 cement : 6 coarse sand) 1135 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1136 Cement mortar 1:4 (1 cement :4 coarse sand 1137 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1138 ELECTRICAL WORK OF GIRLS DORMITORY 1139 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1140 Group B 1141 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1142 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1143 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1144 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1145 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1146 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1147 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1148 Group B 1149 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1150 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1151 2 x 1.5 sq. mm 1152 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1153 25 mm 1154 32 mm 1155 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1156 100 mm X 100 mm X 60 mm deep 1157 150 mm X 75 mm X 60 mm deep 1158 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1159 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1160 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1161 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1162 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1163 4 way (4 + 12), Double door 1164 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1165 Single pole 1166 Single pole and neutral 1167 Triple pole 1168 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1169 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1170 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1171 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 1172 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 1173 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1174 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1175 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1176 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1177 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1178 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1179 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1180 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1181 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1182 Upto 450 mm sweep 1183 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1184 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 1185 450 mm sweep 1400 rpm 1186 COST OF GIRLS 20 (CBRI) - 2 BLOCKS 1187 Structural Repair & Retrofitting 1188 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1189 50mm average thickness 1190 25 mm average thickness 1191 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1192 Bars upto 12 mm diameter 1193 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1194 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1195 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1196 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1197 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1198 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1199 Repairs to Roof 1200 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1201 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1202 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1203 Repair to Toilets 1204 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1205 For thickness of tiles 10 mm to 25 mm 1206 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 1207 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1208 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1209 75 to 80 mm dia pipe 1210 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1211 15 mm to 40 mm nominal bore 1212 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1213 Up to 150 mm diameter 1214 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1215 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1216 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1217 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1218 Up to 150 mm diameter 1219 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1220 Rectangular manhole 90x80 cm and 45 cm deep 1221 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1222 110 mm diameter 1223 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1224 a) Coupler 1225 110 mm 1226 b) Bend 87.5° 1227 110 mm bend 1228 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1229 75 mm diameter pipes 1230 100 mm diameter pipes 1231 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1232 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1233 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1234 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1235 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1236 a) 32mm dia (for wash basin) 1237 b) 40mm dia (for sink and urinal) 1238 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 1239 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1240 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1241 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1242 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1243 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1244 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1245 P-Trap type Floor Trap 110 x 75 mm 1246 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1247 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1248 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1249 Providing & fixing soil, waste and vent pipes. 1250 a) 100mm dia centrifugally cast iron S & S pipe. 1251 b)75mm dia centrifugally cast iron S & S pipe. 1252 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1253 a) for 100mm dia pipe. 1254 b) for 75mm dia pipe. 1255 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1256 a) 100mm 1257 Sand cast iron S&S as per IS - 3989 1258 b) 75mm 1259 Sand cast iron S&S as per IS- 3989 1260 Providing and fixing plaincast iron S & S sanitary bend. 1261 a) 100mm 1262 Sand cast iron S&S as per IS - 1729 1263 b) 75mm 1264 Sand cast iron S&S as per IS - 3989 1265 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1266 a) 100x100x100mm 1267 b) 75x75x75mm 1268 Providing and fixingcast iron terminal guard. 1269 a) 100mm 1270 b) 75mm 1271 Providing & fixingcast iron coller. 1272 a)100 mm 1273 Sand cast iron S&S as per IS - 3989 1274 b)75mm dia. 1275 Sand cast iron S&S as per IS - 3989 1276 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1277 a) 100mm 1278 b) 75mm 1279 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1280 a) 100mm inlet & 75mm outlet. 1281 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1282 15 mm nominal outer dia Pipes 1283 20 mm nominal outer dia Pipes 1284 25 mm nominal outer dia Pipes 1285 32 mm nominal outer dia Pipes 1286 Providing and fixing brass stop cock of approved quality. 1287 15 mm nominal bore 1288 Providing and fixing gun metal gate valve with wheel of approved quality. 1289 a) 25mm dia nominal bore 1290 b) 32mm dia nominal bore 1291 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1292 a) 25mm. Nominal bore 1293 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1294 a) 15mm nominal bore 1295 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1296 a) 15mm nominal bore 1297 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1298 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1299 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1300 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1301 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1302 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1303 a) 15mm nominal bore 1304 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1305 a) 15mm nominal bore 1306 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1307 15mm nominal bore 1308 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1309 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1310 25mm nominal bore, weighing not less than 62 gms 1311 Cutting holes up to 30x30 cm in walls including making good the same: 1312 With common burnt clay F.P.S. (non modular) bricks 1313 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1314 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1315 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1316 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1317 Repair to Plaster and Plinth Protection 1318 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1319 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1320 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1321 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1322 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1323 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1324 With cement mortar 1:4 (1cement: 4 coarse sand) 1325 12mm cement plaster of mix : 1326 1:6 (1 cement : 6 course sand) 1327 6mm cement plaster to ceiling of mix : 1328 1:3 ( 1 cement : 3 fine sand) 1329 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1330 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1331 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1332 Old work (one or more coats) 1333 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1334 Repairs to Door / Windows 1335 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1336 Of area 3 sq. metres and below 1337 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1338 Of area 3 sq. metres and below 1339 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1340 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1341 Renewal of old putty of glass panes (length) 1342 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1343 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1344 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1345 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 1346 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1347 125 X 64 X 1.90 MM 1348 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 1349 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1350 With 12 mm mild steel U beading 1351 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1352 300 mm weighing not less than 200gms. 1353 250 mm weighing not less than 150gms. 1354 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1355 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1356 300 x 10mm 1357 150 x 10mm 1358 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1359 125 mm 1360 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1361 Using flats 30x6mm for diagonal braces and central cross piece 1362 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1363 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1364 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqm 1365 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1366 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1367 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1368 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1369 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1370 4.0 mm thick glass panes 1371 Applying priming coat : 1372 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1373 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1374 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1375 Two or more coats on new work 1376 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1377 One or more coats on old work 1378 Miscellaneous 1379 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1380 In cement mortar 1381 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1382 Cement mortar 1:6 (1 cement : 6 coarse sand) 1383 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1384 Cement mortar 1:4 (1 cement :4 coarse sand 1385 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1386 ELECTRICAL WORK OF GIRLS DORMITORY 1387 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1388 Group B 1389 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1390 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1391 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1392 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1393 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1394 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1395 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1396 Group B 1397 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1398 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1399 2 x 1.5 sq. mm 1400 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1401 25 mm 1402 32 mm 1403 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1404 100 mm X 100 mm X 60 mm deep 1405 150 mm X 75 mm X 60 mm deep 1406 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1407 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1408 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1409 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1410 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1411 4 way (4 + 12), Double door 1412 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1413 Single pole 1414 Single pole and neutral 1415 Triple pole 1416 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1417 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1418 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1419 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 1420 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 1421 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1422 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1423 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1424 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1425 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1426 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1427 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1428 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1429 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1430 Upto 450 mm sweep 1431 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1432 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 1433 450 mm sweep 1400 rpm 1434 COST OF GIRLS DORM - CPWD (1 BLOCK) 1435 Structural Repair & Retrofitting 1436 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1437 50mm average thickness 1438 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1439 Bars upto 12 mm diameter 1440 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1441 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1442 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1443 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1444 Repairs to Roof 1445 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1446 In cement mortar 1447 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1448 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1449 Repair to Toilets 1450 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1451 For thickness of tiles 10 mm to 25 mm 1452 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 1453 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1454 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1455 75 to 80 mm dia pipe 1456 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1457 15 mm to 40 mm nominal bore 1458 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1459 Up to 150 mm diameter 1460 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1461 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1462 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1463 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1464 Up to 150 mm diameter 1465 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1466 Rectangular manhole 90x80 cm and 45 cm deep 1467 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1468 110 mm diameter 1469 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1470 a) Coupler 1471 110 mm 1472 b) Bend 87.5° 1473 110 mm bend 1474 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1475 75 mm diameter pipes 1476 100 mm diameter pipes 1477 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1478 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1479 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1480 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1481 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1482 a) 32mm dia (for wash basin) 1483 b) 40mm dia (for sink and urinal) 1484 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 1485 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1486 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1487 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1488 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1489 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1490 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1491 P-Trap type Floor Trap 110 x 75 mm 1492 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1493 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1494 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1495 Providing and fixing toilet paper holder : 1496 Vitreous china 1497 Providing & fixing soil, waste and vent pipes. 1498 a) 100mm dia centrifugally cast iron S & S pipe. 1499 b)75mm dia centrifugally cast iron S & S pipe. 1500 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1501 a) for 100mm dia pipe. 1502 b) for 75mm dia pipe. 1503 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1504 a) 100mm 1505 Sand cast iron S&S as per IS - 3989 1506 b) 75mm 1507 Sand cast iron S&S as per IS- 3989 1508 Providing and fixing plaincast iron S & S sanitary bend. 1509 a) 100mm 1510 Sand cast iron S&S as per IS - 1729 1511 b) 75mm 1512 Sand cast iron S&S as per IS - 3989 1513 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1514 a) 100x100x100mm 1515 b) 75x75x75mm 1516 Providing and fixingcast iron terminal guard. 1517 a) 100mm 1518 b) 75mm 1519 Providing & fixingcast iron coller. 1520 a)100 mm 1521 Sand cast iron S&S as per IS - 3989 1522 b)75mm dia. 1523 Sand cast iron S&S as per IS - 3989 1524 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1525 a) 100mm 1526 b) 75mm 1527 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1528 a) 100mm inlet & 75mm outlet. 1529 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1530 15 mm nominal outer dia Pipes 1531 20 mm nominal outer dia Pipes 1532 25 mm nominal outer dia Pipes 1533 32 mm nominal outer dia Pipes 1534 Providing and fixing brass stop cock of approved quality. 1535 15 mm nominal bore 1536 Providing and fixing gun metal gate valve with wheel of approved quality. 1537 a) 25mm dia nominal bore 1538 b) 32mm dia nominal bore 1539 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1540 a) 25mm. Nominal bore 1541 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1542 a) 15mm nominal bore 1543 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1544 a) 15mm nominal bore 1545 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1546 a) 15mm nominal bore 1547 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1548 a) 15mm nominal bore 1549 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1550 15mm nominal bore 1551 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1552 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1553 25mm nominal bore, weighing not less than 62 gms 1554 Cutting holes up to 30x30 cm in walls including making good the same: 1555 With common burnt clay F.P.S. (non modular) bricks 1556 Repair to Plaster and Plinth Protection 1557 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1558 Two or more coats on new work 1559 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1560 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1561 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1562 15mm cement plaster on rough side of single or half brick wall of mix 1563 1:6 (1 cement : 6 course sand) 1564 6mm cement plaster to ceiling of mix : 1565 1:3 ( 1 cement : 3 fine sand) 1566 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1567 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1568 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1569 Old work (one or more coats) 1570 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1571 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 1572 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 1573 15 mm wide and 15 mm deep groove 1574 Repairs to Door / Windows 1575 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1576 Of area 3 sq. metres and below 1577 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1578 Of area 3 sq. metres and below 1579 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1580 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1581 Renewal of old putty of glass panes (length) 1582 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 1583 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1584 250 mm weighing not less than 150gms. 1585 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1586 100X58X1.90 mm 1587 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1588 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1589 300 x 10mm 1590 150 x 10mm 1591 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1592 125 mm 1593 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1594 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1595 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1596 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 1597 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1598 125 X 64 X 1.90 MM 1599 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1600 With 12 mm mild steel U beading 1601 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1602 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1603 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqm 1604 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1605 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1606 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1607 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1608 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1609 4.0 mm thick glass panes 1610 Applying priming coat : 1611 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1612 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1613 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1614 Two or more coats on new work 1615 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1616 One or more coats on old work 1617 Miscellaneous 1618 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1619 In cement mortar 1620 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1621 Cement mortar 1:6 (1 cement : 6 coarse sand) 1622 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1623 Cement mortar 1:4 (1 cement :4 coarse sand 1624 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1625 ELECTRICAL WORK OF GIRLS DORM - 24 CPWD ( 1 BLOCK) 1626 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1627 Group B 1628 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1629 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1630 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1631 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1632 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1633 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1634 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1635 Group B 1636 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1637 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1638 2 x 1.5 sq. mm 1639 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1640 25 mm 1641 32 mm 1642 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1643 100 mm X 100 mm X 60 mm deep 1644 150 mm X 75 mm X 60 mm deep 1645 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1646 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1647 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1648 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1649 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1650 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1651 4 way (4 + 12), Double door 1652 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1653 Single pole 1654 Single pole and neutral 1655 Triple pole 1656 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1657 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1658 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1659 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1660 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1661 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1662 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1663 COST OF WORKSHOP 1664 Repairs to Roof 1665 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 1666 Asbestos Cement sheet 1667 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 1668 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 1669 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* 1670 Repair to Plaster and Plinth Protection 1671 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1672 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1673 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1674 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1675 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1676 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1677 With cement mortar 1:4 (1cement: 4 coarse sand) 1678 12mm cement plaster of mix : 1679 1:6 (1 cement : 6 course sand) 1680 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1681 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1682 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1683 Old work (one or more coats) 1684 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1685 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1686 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1687 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1688 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1689 Repairs to Door / Windows 1690 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1691 Of area 3 sq. metres and below 1692 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1693 Of area 3 sq. metres and below 1694 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1695 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1696 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1697 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 1698 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1699 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1700 300 x 10mm 1701 150 x 10mm 1702 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1703 125 mm 1704 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1705 Twin rubber stopper 1706 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1707 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1708 ALUMINIUM WORK 1709 Supply & fixing of Aluminium 3 Track Sliding windows as per design & specifications with outer frame 86.5mm X 48mm, Shutter section 65mm X 29mm, Mesh Shutter 66.7mm X 29mm, Powder coated (any RAL Colour), 6mm Clear tuffened glass, Wire Mesh, Handle, EPDM Gasket, Silicon sealant with complete hardware of reputed brand, (Make: A2Z Infra Solutions / Urban Space / Elixir Metform Pvt Ltd) 1710 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 1711 For fixed portion 1712 Powder coated aluminium (minimum thickness of powder coating 50 micron 1713 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 1714 Powder coated aluminium (minimum thickness of powder coating 50 micron) 1715 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1716 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) 1717 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 1718 With stainless steel cover plate minimum 1.25 mmthickness 1719 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 1720 Upto 5mm depth and 5 mm width 1721 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-incharge.(Only weight of grill to be measured for payment). 1722 Applying priming coat : 1723 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1724 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1725 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1726 Two or more coats on new work 1727 Flooring 1728 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1729 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1730 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1731 25 mm thick 1732 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1733 Miscellaneous 1734 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, ransporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 1735 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1736 In cement mortar 1737 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1738 Cement mortar 1:6 (1 cement : 6 coarse sand) 1739 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1740 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 1741 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1742 75 to 80 mm dia pipe 1743 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1744 110 mm diameter 1745 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1746 a) Coupler 1747 110 mm 1748 b) Bend 87.5° 1749 110 mm bend 1750 ELECTRICAL WORK 1751 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1752 Group C 1753 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1754 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1755 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1756 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1757 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1758 2 x 1.5 sq. mm 1759 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1760 25 mm 1761 32 mm 1762 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1763 100 mm X 100 mm X 60 mm deep 1764 150 mm X 75 mm X 60 mm deep 1765 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1766 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1767 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1768 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1769 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1770 6 way, Double door 1771 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1772 4 way (4 + 12), Double door 1773 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1774 Single pole 1775 Single pole and neutral 1776 Triple pole 1777 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1778 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1779 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1780 Upto 450 mm sweep 1781 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1782 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1783 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1784 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1785 Supply of 30W LED recess mounted fixtureMAKE-PHILIPS CAT NO.RC380B LED30S-6500 L60W60 PSD OD S1 or equivalent. 1786 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1787 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 1788 450 mm sweep 1400 rpm 1789 EXTERNAL SEWERAGE SYSTEM 1790 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1791 All kinds of soil 1792 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1793 Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1794 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1795 150 mm dia. R.C.C. pipe 1796 450 mm dia. R.C.C. pipe 1797 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) 1798 150 mm diameter S.W.Pipe (L*.35*.10) 1799 450 mm diameter S.W.Pipe (L*.6*.15 ) 1800 Constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 1801 Inside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 1802 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 1803 Extra for depth for manholes: 1804 size 90 X 80 cm 1805 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1806 Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricksclass designation 75in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1807 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 1808 with common burnt clay F.P.S.(non module) brick of class designation 7.5 1809 Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 1810 with common burnt clay F.P.S.(non module) brick of class designation 7.5 1811 Providing and fixing square mouthS. W. Gully trapclass SP-1 complete with C.I. gratingbrickmasonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1812 180 x 150 mm. size P type 1813 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1814 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1815 With 20x20 mm square bar 1816 Cleaning of chocked sewer line by diesel running vehicle mountinghydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm 1817 Cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of Engineer-in-charge. 1818 SEPTIC TANK ( 20 USERS) 1819 Size of Tank = 2.30 X 1.10 X 1.80 Mtr 1820 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1821 all kinds soil 1822 Take 50 % Qty of items 1.A 1823 ordinary rock 1824 Take 50 % Qty of items 1.A 1825 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1826 Earth work in Excavation 1.50-3.00 mtr 1827 all kinds soil 1828 Take 50 % Qty of items 2.A 1829 ordinary rock 1830 Take 50 % Qty of items 2.A 1831 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1832 20 % of excavation of items (1.A.1+2.A.1) 1833 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1834 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). 1835 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). 1836 Centering and shuttering including strutting, propping etc. and removal of form for: 1837 Foundations, footings, bases of columns, etc. for mass concrete. 1838 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 1839 Edges of slabs and breaks in floors and walls. 1840 Under 20 cm wide 1841 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 1842 Thermo-Mechanically Treated bars. 1843 52 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 1844 for maintaining slope 1845 6 mm cement plaster on rough side of single or half brick wall of mix: 1846 1:3 (1 cement: 3fine sand) 1847 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1848 HD-20 1849 Circular shape 560 mm internal diameter 1850 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1851 Providing and fixing soil, waste and vent pipes 1852 100 mm dia. 1853 Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 1854 Providing and fixing terminal guard : 1855 100 mm 1856 Sand cast iron S&S as per IS - 3989 1857 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 1858 SEPTIC TANK ( 50 USERS) 1859 Size of Tank = 5.00 X 2.00 X 1.24 Mtr 1860 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1861 All kinds of soil 1862 Take 50 % Qty of items 1.A 1863 ordinary rock 1864 Take 50 % Qty of items 1.A 1865 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1866 Earth work in Excavation 1.50-3.00 mtr 1867 all kinds soil 1868 Take 50 % Qty of items 2.A 1869 ordinary rock 1870 Take 50 % Qty of items 2.A 1871 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1872 20 % of excavation of items (1.A.1+2.A.1) 1873 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1874 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). 1875 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). 1876 Upto plinth level 1877 Centering and shuttering including strutting, propping etc. and removal of form for: 1878 Foundations, footings, bases of columns, etc. for mass concrete. 1879 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 1880 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 1881 RCC Bend Beam 1882 Suspended floors, roofs, landings, balconies and access platform. 1883 Edges of slabs and breaks in floors and walls. 1884 Under 20 cm wide 1885 Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge. 1886 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 1887 Thermo-Mechanically Treated bars. 1888 52 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 1889 6 mm cement plaster on rough side of single or half brick wall of mix: 1890 1:3 (1 cement: 3 fine sand) 1891 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1892 HD-20 1893 Circular shape 560 mm internal diameter 1894 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1895 Providing and fixing soil, waste and vent pipes 1896 100 mm dia. 1897 Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 1898 Providing and fixing terminal guard : 1899 100 mm 1900 Sand cast iron S&S as per IS - 3989 1901 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 1902 SOAK PIT 1903 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 1904 FOR STAFF QTRS FOR EXISTING SEPTIC TANK 1905 Total 1906 ELECTRICAL WORKS 1907 SUBHEAD - I - MAIN BOARDS 1908 METER BOARDS 1909 Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CTs, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingMCBs MCCBs and kWh meters complete as required. 1910 METER BOARDS - TYPE-III (3 NOS), WARDEN RESIDENCE ( 2 NOS), TYPE-1 (6 NOS), TYPE-2 (3 NOS) 1911 INCOMER 1912 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1913 METERING & INDICATION 1914 1 set of R,Y,B phase indicating lamps 1915 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1916 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1917 BUS-BAR 1918 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1919 OUT GOING: 1920 4 Nos. 40A TPN MCB of 10kA 1921 2 Nos. 40A DP MCB of 10kA. 1922 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1923 METER BOARDS -DORMITORY BOYS & GIRLS 1924 INCOMER 1925 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1926 METERING & INDICATION 1927 1 set of R,Y,B phase indicating lamps 1928 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1929 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1930 BUS-BAR 1931 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1932 OUT GOING: 1933 4 Nos. 40A TPN MCB of 10kA 1934 2 Nos. 40A DP MCB of 10kA. 1935 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1936 PANEL -MP HALL & SCHOOL 1937 INCOMER 1938 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1939 METERING & INDICATION 1940 1 set of R,Y,B phase indicating lamps 1941 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1942 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1943 BUS-BAR 1944 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1945 OUT GOING: 1946 4 Nos. 40A TPN MCB of 10kA 1947 3 No. 40A DP MCB of 10kA. 1948 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1949 SUBHEAD - II - EARTHING 1950 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 1951 Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (CI heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 1952 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. 1953 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 1954 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1955 BOREWELL 180 MTR DEEP 1956 Sub Head : I Tubewells 1957 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different trata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 1958 All Type of Soil 1959 400mm dia 1960 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 1961 All Type of Soil 1962 400mm dia 1963 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 1964 200 mm nominal size dia having minimum wall thickness5.40 mm 1965 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 1966 200 mm nominal size dia 1967 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge. 1968 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 1969 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 1970 200 mm dia 1971 Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 1972 200 mm clamp 1973 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 1974 200 mm nominal size dia 1975 Supply, installation testing & commissioning of borewell submersible pumping set suitable to operate on 415 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 200 mm outer dia uPVC Pipe as per IS : 12818with fittings, clamps etc. complete in all respect as per details given below : 1976 Pump Motor shall be Class F Insulation , Pump and Motor shall be IP : 68 Protection Rating , and Motor Efficiency shall be Class IE-3 Efficiency . 1977 Pump to be lowered below groundas site Boring/drilling 1978 Pump capacity : 15000 litres/hr 1979 Head : 250M 1980 H.P : 15 ( Approx) 1981 Totalof one set Tubewell 1982 Provding and fixing heavy duty 65mm G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above with reducers, tees, flanges, elbow, crosses, union etc. and fixing the pipes onwall / ceiling / beam / floor including Clamping/Supporting the same, including painting with 2 coats of synthetic enamel paint as per the site requirement and shall be duly painted with two coats of approved quality synthetic enamel paint & shade over a readymix primer coat complete as required & as per directions of the engineer-in-charge for the following sizes: 1983 PANEL(Outdoor Type weather proof, double door with canopy and suitable MS Structure stand duly painted) 1984 INCOMER 1985 1 No.100 Amp FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1986 Metering & Indication 1987 1 set of RYB phase indicating lamps 1988 MFM with Communication Facility along with control SP MCB 1989 Surge protection device , Type 2, MOV type for 8/20 us wave, 3 Nos phase to neutral, one No neutral to earth ,(minimum 3+1 mode) with minimum discharge capacity 40KA along with necessary fuses. 1990 BUS-BAR 1991 1 Set of 125A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1992 OUTGOINGS 1993 3 Nos. 40A TPN MCB 1994 3 Nos. 25A DP MCB 1995 3 Nos. 20A DP MCB 1996 Plumbing Panel 1997 NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays 1998 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1999 DEMOLTION WORK OF OVER HEAD TANK
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
26.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
27.
Housing Urban and Rular Development #9475738 Technical Bid
Tender For Construction Of Administrative Block Cyber Thana At Ambedkarnagar -Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavation in foundation in ordinary soil (loam clay or sand) inluding lift upto 1.5 metres and lead upto 30 metres & including filling, watering & ramming of excavated earth into the trenches or into the spacebetween the buildings & the sides of foundation trenchesor into the plinth and removal & disposal & surplus earth as directed by the Engineer-in-charge upto a distance of30 m from the foundation trenches 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping eFoundations, footings, bases of columns, etc. for mass concrete.tc. and removal of form for all heights : 10 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. : 11 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 12 Columns,Pillars, Piers, Abutments, Posts and Struts. 13 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 14 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 16 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 19 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :R.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete) 20 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. columns in 1:1.5:3 having strength not less than M-20. 21 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 23 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 24 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 28 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 29 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 30 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 31 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 32 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 33 Supply & fixing of flush Doors commercial quality Conforming to 1.S. 2202 Part I (1983) Including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges. Bolts locks, handles,springs. Fitting with necessary screws to be supplied departmentally. 35 mm thick 34 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 37 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 38 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 39 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 40 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 41 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 42 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning (b)Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. the surface beforetreatment.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 43 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 44 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 45 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 46 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 47 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 12 mmthickcementplasterindado/ skirting in 1:3 consisting of one part of cement and 3 partsof aprovedcoarsesand laid inpanels,finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required forpropercompletionofthe work. 51 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) laid in one layer finished with a floating coats neat cement (40 mm thickfloor). 52 Making groove 10x12 mm widex 8 mm deep in plaster of the wall or in ceilling vertically or horizontally as required AND .Add for groove in plastered surface or moulding to R.C.C. projections 53 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 54 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 55 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] 56 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 57 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm 58 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 59 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 60 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 61 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 62 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 63 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 64 ainting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 65 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 66 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 67 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 68 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 69 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 70 Coupler 110 mm 71 Bend 87.5° 110 mm bend 72 Shoe (Plain) 110 mm Shoe 73 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 74 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. 75 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 76 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 77 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 78 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 79 For vertical surface two coats @ 0.70 kg per sqm 80 For horizontal surface one coat @1.10 kg per sqm. 81 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 82 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 83 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 84 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank 85 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 86 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 87 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 88 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 89 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 90 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 91 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 92 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 93 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 94 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 95 90 mm O.D. 96 110 mm O.D. 97 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 98 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 99 90 mm size 100 110 mm size 101 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 102 75 mm Shoe 103 110 mm Shoe 104 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 105 90x90x90 mm size 106 110x110x110 mm size 107 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 108 90 mm size 109 110 mm size 110 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 111 90 mm size 112 110 mm size 113 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 114 90 mm size 115 110 mm size 116 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 118 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 119 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 120 20 mm nominal outer dia pipes 121 25 mm nominal outer dia pipes 122 40 mm nominal outer dia pipes 123 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 124 15 mm nominal outer dia pipes 125 20 mm nominal outer dia pipes 126 25 mm nominal outer dia Pipes 127 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 128 25mm dia, nominal bore 129 32 mm dia, nominal bore 130 40 mm dia, nominal bore 131 50 mm dia, nominal bore 132 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 133 25 to 40 mm nominal bore 134 50 to 80 mm nominal bore 135 Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore: 136 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) 137 20 mm nominal outer dia pipes 138 25 mm nominal outer dia pipes 139 32 mm nominal outer dia pipes 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 141 20 mm nominal bore 142 25 mm nominal bore 143 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115mm nominal bore 144 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore 145 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 146 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 147 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 148 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 149 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 150 S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work.150mm dia SWR Pipe 151 Haunching of SWR Pipes with cement concrete in 1:2:4 (1 cement: 2 coarse sand : 4 Stone grit 20mm nominal size) with a complete section of size 300x300mm around the pipe. Including supply of all materials and Labour complete. 152 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 153 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75i) For Sewer Line 154 (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. 155 Extra for depth of man hole size 90x80 cm 156 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia 157 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design180 x 150 mm. size P type 158 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 159 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 160 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 161 50mm nominal bore. 162 40mm nominal bore. 163 32mm nominal bore. 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 165 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 166 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 168 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 169 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 170 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 171 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 172 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 173 Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 174 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 175 5/6 A switch 176 3 pin 5/6 A socket outlet 177 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 178 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 179 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 180 Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 181 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 182 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 183 Installation of Upto 450 mm sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 184 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 185 Supplying and drawing 2 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 186 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 187 Supplying and drawing of 1 run of cable UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 188 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 189 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 190 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 191 4 way (4 + 12), Double door 192 6 way (4 + 18), Double door 193 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG 194 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 195 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 196 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 197 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 198 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 199 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 200 40 A 201 63 A 202 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 203 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 204 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 205 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 206 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 207 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel : Incoming - 200 Amp MCCB - 1 No. Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No. (Complete as per requirment directed by E/I) 208 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 209 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 15 to 18 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 210 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 211 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 212 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 213 size 6 sq mm x 2 core 214 size 70 sq mm x 3-1/2core 215 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 216 2 X 6 sq. mm (19mm) 217 3½ X 70 sq. mm (32mm) 218 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 219 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 220 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 221 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 222 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 223 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 224 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 225 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 226 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 227 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 228 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 229 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 230 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 231 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 232 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 233 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 234 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 235 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 236 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 450 lpm at 35 m Head ipes & Accessories : 237 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 238 80 mm dia 239 100 mm dia 240 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 241 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 242 80 mm dia 243 100 mm dia 244 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 245 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 246 80 mm dia 247 100 mm dia 248 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 249 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 250 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 251 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 252 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 253 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 254 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 255 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 25 sq mm x 3-1/2core 256 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 257 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 258 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Fire Sand Bucket : 259 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 260 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 261 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 262 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 263 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 264 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 265 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 266 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 267 Control Panels (for Terrace Pump) :Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 268 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 269 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 270 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 271 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. 272 Providing and fixing in position pre-moulded joint filler in expansion joints. 273 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. 274 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 275 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 276 Supplying, installation, testing and commissioning ofL.T. panel fully compartmentalized cubical type sheet clad floor mounted totally enclosed , extensible on both sides, switch board suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, as required as per specification and schematic diagram as required. (Street lighting Panel) INCOMER:-1 Nos.63 Amps. TPN MCCB(25 KA) 1 Nos.63 Amps. Automatic changeover switch 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASS BUS BARS:- 100 Amps. TP&N Aluminium bus bars (25 KA) OUT GOINGS:- 6 Nos.32A TPN, MCB (10KA). 4 Nos. 24 Hr Timer Switch 4 Nos. 32A TPN contactor 277 Supplying, installation & testing of 6.0 m high Octagonal pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 130mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 4Cx16 sq.mm YWY cables and 3x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost ofRCC foundation for pole as per structural detail. 278 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 Protection complete in all respect 279 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 Sq mm x 4 Core 280 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 16 Sq mm x 4 Core 281 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.16 Sq mm MR 282 S.I.T.C. of IP Based EPABX System comprising of core switches and L switch with 10g, 10 Giga SFP modules, industry standard appliance server, cloud based, interprise -grade UC solution, MID/ENTRY Level IP/SIP Phone with dual 1 gig ports, racks,CAT6A cable, patch panels, OFC etc. 283 S.I.T.C. of LAN System comprising of core switches and L switch with 10g, 10 Giga SFP modules WIFIAccess points WIFI controller network management software racks, CAT 6A Cable patch panels OFC etc. , 284 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 285 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 286 Providing & fixing 75mm dia vent pipes. 287 Providing & fixing of 75mm dia cast iron terminal guard. 288 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 560mm internal diameter 289 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 400 mm dia 291 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 292 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, i200 mm nominal size diancluding hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 293 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 294 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 295 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 296 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 297 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 298 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 299 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 300 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 10.1 301 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 302 ANGLE IRON90*90*6 mm 303 T-SECTION 90*90*6 304 HOLD FAST40*6 FLAT 305 G.I. Pipe(80 MM DIA) (DSR-18.12.8)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
28.
Heavy Industries and Public Enterprises #9472378 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Amausi (Part-1) District Lucknow Under Aiim-2 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.(as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete asrequired.(as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.(as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.)(as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 59 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 62 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 65 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 66 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 67 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 68 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 69 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 74 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 75 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 76 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 77 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate(as per UPPWD approved make list) 78 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate (as per UPPWD approved make list) 79 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 80 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 81 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia(as per UPPWD approved make list) 82 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 83 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned(as per UPPWD approved make list) 84 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Havells, Polycab, Grandlay, Gloster, KEI make) 85 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 86 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 87 Lettering with black japan paint of approved brand and manufacturer(as per UPPWD approved make list) 88 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 89 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 90 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 91 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 93 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 96 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 97 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 300 sq.mm 3 core 11 KV HT XLPE Cable (Havells, Polycab, Grandlay, Gloster, KEI make) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc.. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Havells, Polycab, Grandlay, Gloster, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 103 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 104 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates as per sanctioned vide job no.ED-1 (83) Dt. 25.11.2021(as per UPPWD approved make list) 105 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 106 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल )(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 110 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 111 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 112 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 113 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 114 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 115 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I.(as per UPPWD approved make list) 116 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.(as per UPPWD approved make list) 117 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 119 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 123 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 124 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 125 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 127 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.. Main LT Panel #1 INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 128 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 129 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 130 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havewlls, Polycab, Grandlay, Gloster, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havewlls, Polycab, Grandlay, Gloster, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Havells, Polycab, Grandlay, Gloster, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells, Polycab, Grandlay, Gloster, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 136 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 137 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 138 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells, Polycab, Grandlay, Gloster, KEI make) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 145 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 146 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 155 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 156 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 157 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 158 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed atsite by Engineer in charge.(as per UPPWD approved make list) 159 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 160 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 161 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 163 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 164 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 165 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable)(as per UPPWD approved make list) 166 Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P.(as per UPPWD approved make list) 167 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 170 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 171 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 172 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 173 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 174 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
29.
Heavy Industries and Public Enterprises #9463652 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area Naini Prayagraj (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. (as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 13 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 16 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 18 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 19 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (as per UPPWD approved make list) 20 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (as per UPPWD approved make list) 21 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (as per UPPWD approved make list) 22 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 24 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 25 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 26 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 29 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 30 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 31 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required (as per UPPWD approved make list) 32 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 33 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 34 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 36 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 37 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 38 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 39 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard. (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 45 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 46 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (as per UPPWD approved make list) 47 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 48 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 50 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 51 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 52 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 53 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 54 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 55 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 57 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. Incomer100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos, 100/5A 5VA class 1 resin cast CT - 1 set Outgoing. 63 A FP 10 kA MCB - 2 nos. , 40 A DP 10 kA MCB - 20 nos.(as per UPPWD approved make list) 60 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 63 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 66 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 67 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 68 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection(as per UPPWD approved make list) 69 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 74 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 75 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 76 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 77 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 78 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 79 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(61) dated 22.10.2020(as per UPPWD approved make list) 80 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023(as per UPPWD approved make list) 81 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 82 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 83 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia (as per UPPWD approved make list) 84 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 85 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned Estimate Job No. ED-1(61) dated 22.10.2020 (as per UPPWD approved make list) 86 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properly connected with earth conductor by clamps etc. (Havells,Polycab,Grandlay,Gloster,KEI) 87 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 88 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 89 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 90 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kg(as per UPPWD approved make list) 91 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I. (as per UPPWD approved make list) 92 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I. 93 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I. (as per UPPWD approved make list) 94 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I. (as per UPPWD approved make list) 95 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. 96 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I. (as per UPPWD approved make list) 97 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications. (as per UPPWD approved make list) 98 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor (as per UPPWD approved make list) 99 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 185 sq.mm 3 core 11 KV HT XLPE Cable (Havells,Polycab,Grandlay,Gloster,KEI) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB). ( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021 (as per UPPWD approved make list) 103 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P. (as per UPPWD approved make list) 104 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल ) (as per UPPWD approved make list) 105 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect. (as per UPPWD approved make list) 109 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (as per UPPWD approved make list) 110 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 111 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.. (as per UPPWD approved make list) 112 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 113 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I. (as per UPPWD approved make list) 114 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I. (as per UPPWD approved make list) 115 Supply & Installation of Top Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 116 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 117 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I. (as per UPPWD approved make list) 118 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work. (as per UPPWD approved make list) 119 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I. (as per UPPWD approved make list) 120 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 121 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 122 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 123 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 124 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havells,Polycab,Grandlay,Gloster,KEI) 125 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havells,Polycab,Grandlay,Gloster,KEI) 126 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe)(Havells,Polycab,Grandlay,Gloster,KEI) 127 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells,Polycab,Grandlay,Gloster,KEI) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 132 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 133 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 134 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 135 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 140 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 141 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 142 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 143 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 151 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. (as per UPPWD approved make list) 152 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 153 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 154 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge.(as per UPPWD approved make list) 155 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 156 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 157 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 158 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to Nagar Nigam Store as per direction of E/I. (as per UPPWD approved make list) 159 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 160 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 161 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 162 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work. (as per UPPWD approved make list) 163 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P. (as per UPPWD approved make list) 164 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect. (as per UPPWD approved make list) 165 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I. (as per UPPWD approved make list) 166 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe.(as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
30.
Heavy Industries and Public Enterprises #9460660 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Amausi (Part-1) District Lucknow Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.(as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required.(as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete asrequired.(as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.(as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.)(as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 59 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 62 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 65 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 66 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 67 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 68 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 69 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 74 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 75 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 76 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 77 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate(as per UPPWD approved make list) 78 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate (as per UPPWD approved make list) 79 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 80 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 81 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia(as per UPPWD approved make list) 82 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 83 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned(as per UPPWD approved make list) 84 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Havells, Polycab, Grandlay, Gloster, KEI make) 85 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 86 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 87 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021(as per UPPWD approved make list) 88 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 89 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 90 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 91 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 93 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 96 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 97 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 300 sq.mm 3 core 11 KV HT XLPE Cable (Havells, Polycab, Grandlay, Gloster, KEI make) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc.. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Havells, Polycab, Grandlay, Gloster, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 103 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 104 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates as per sanctioned vide job no.ED-1 (83) Dt. 25.11.2021(as per UPPWD approved make list) 105 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 106 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल )(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 110 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 111 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 112 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 113 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 114 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 115 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I.(as per UPPWD approved make list) 116 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.(as per UPPWD approved make list) 117 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 119 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 123 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 124 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 125 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 127 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.. Main LT Panel #1 INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 128 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 129 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 130 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havewlls, Polycab, Grandlay, Gloster, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havewlls, Polycab, Grandlay, Gloster, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Havells, Polycab, Grandlay, Gloster, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells, Polycab, Grandlay, Gloster, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 136 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 137 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 138 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells, Polycab, Grandlay, Gloster, KEI make) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 145 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 146 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 155 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 156 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 157 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 158 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed atsite by Engineer in charge.(as per UPPWD approved make list) 159 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 160 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 161 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 163 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 164 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 165 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable)(as per UPPWD approved make list) 166 Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P.(as per UPPWD approved make list) 167 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 170 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 171 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 172 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 173 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 174 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
31.
Heavy Industries and Public Enterprises #9460658 Technical Bid
tender for Electrical Upgradation Of Upsida Industrial Area, Ram Nagar Phase-I And Ii, Chandauli (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. (as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required. (as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door (as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required (as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories. (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty) (as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply (as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required (as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos.(as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. Incomer100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos, 100/5A 5VA class 1 resin cast CT - 1 set Outgoing. 63 A FP 10 kA MCB - 2 nos. , 40 A DP 10 kA MCB - 20 nos.(as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 66 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness (as per UPPWD approved make list) 67 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection(as per UPPWD approved make list) 68 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I. (as per UPPWD approved make list) 69 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area.complete in all respect as per direction of E/I. (as per UPPWD approved make list) 70 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 71 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I. (as per UPPWD approved make list) 72 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 73 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 74 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED (as per UPPWD approved make list) 75 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M (as per UPPWD approved make list) 76 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules completein all respect. (as per UPPWD approved make list) 77 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification. (as per UPPWD approved make list) 78 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(61) dated 22.10.2020 (as per UPPWD approved make list) 79 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023 (as per UPPWD approved make list) 80 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I. (as per UPPWD approved make list) 81 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect. (as per UPPWD approved make list) 82 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia (as per UPPWD approved make list) 83 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete inall respect as per direction of E/I. (as per UPPWD approved make list) 84 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I(as per UPPWD approved make list) 85 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 86 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 87 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates (as per UPPWD approved make list) 88 Lettering with black japan paint of approved brand and manufacturer (as per UPPWD approved make list) 89 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 90 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area.complete in all respect as direction of E/I. (as per UPPWD approved make list) 91 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I. (as per UPPWD approved make list) 92 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P ,men material for completion of Work complete in all respect as direction of E/I. (as per UPPWD approved make list) 93 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I. (as per UPPWD approved make list) 94 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect. UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 95 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I. (as per UPPWD approved make list) 96 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications. (as per UPPWD approved make list) 97 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor (as per UPPWD approved make list) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB). )Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB). Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB). Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. (as per UPPWD approved make list) 103 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 104 Lettering with black japan paint of approved brand and manufacturer (11KV भूिमगत केबल )(as per UPPWD approved make list) 105 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 108 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect. (as per UPPWD approved make list) 109 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (fromappron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thickalround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (as per UPPWD approved make list) 110 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as requiredcomplete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 111 Deigging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I. (as per UPPWD approved make list) 112 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 113 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 114 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 115 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 116 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 117 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 119 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect. UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Main LT Panel #1INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos. (as per UPPWD approved make list) 123 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. Sub LT PanelIncomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 124 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type (as per UPPWD approved make list) 125 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 127 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 134 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core(as per UPPWD approved make list) 135 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core(as per UPPWD approved make list) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core(as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core(as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core(as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core(as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core(as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core(as per UPPWD approved make list) 142 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm(as per UPPWD approved make list) 143 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm(as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm(as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm(as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm(as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm(as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm(as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm(as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm(as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm(as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm(as per UPPWD approved make list) 153 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V gradesingle core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed (as per UPPWD approved make list) 154 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal)(as per UPPWD approved make list) 155 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal)(as per UPPWD approved make list) 156 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 157 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used)(as per UPPWD approved make list) 158 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable(as per UPPWD approved make list) 159 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used)(as per UPPWD approved make list) 160 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to JE store as per direction of E/I.(as per UPPWD approved make list) 161 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 162 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 163 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable, Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 164 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <=0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstruction cement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 165 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 166 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 167 Supply , installation of 5 zone central control unit (main frame) configured for 512 station,connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 168 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 corepower cable in 50mm Dia HDPE Pipe.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
32.
Heavy Industries and Public Enterprises #9460652 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 10 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 11 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 13 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 14 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 16 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 17 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 18 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 19 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 20 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 21 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 22 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 24 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 25 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 26 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 27 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 28 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 8 way, Double door(as per UPPWD approved make list) 29 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 30 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 31 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 32 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 33 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 34 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 35 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 36 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 37 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 38 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 39 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 40 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 41 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton). 45 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 46 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 47 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(as per UPPWD approved make list) 48 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 49 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 50 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 51 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 52 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 53 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 54 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 55 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 56 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 57 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 58 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 60 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 63 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 66 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 67 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 68 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 69 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I. (as per UPPWD approved make list) 70 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 74 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 75 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 76 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 77 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect. (as per UPPWD approved make list) 78 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 79 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) (as per UPPWD approved make list) 80 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023(as per UPPWD approved make list) 81 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 82 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 83 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps. i) 100mm dia (as per UPPWD approved make list) 84 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 85 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates(as per UPPWD approved make list) 86 Supply , Laying , Testing & Commissioning of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Grandlay, Gloster, Polycab, Havells, KEI make) 87 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 88 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework.(as per UPPWD approved make list) 89 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021(as per UPPWD approved make list) 90 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 91 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 93 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 96 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 97 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 98 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 99 Supply, laying, Testing & Commissioning of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc..185 sq.mm 3 core 11 KV HT XLPE Cable(Grandlay, Gloster, Polycab, Havells, KEI make) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB) with SCADA compatible. ( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 103 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 104 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 105 Lettering with black japan paint of approved brand and manufacturer (11KV भूमिगत केबल )(as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 110 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 111 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 112 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I. (as per UPPWD approved make list) 113 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 114 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 115 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I. (as per UPPWD approved make list) 116 Supply & Installation of Top Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 117 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 118 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I. (as per UPPWD approved make list) 119 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 120 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I. (as per UPPWD approved make list) 121 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 122 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 123 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 800 Amp. MCCB-1 NoOUTGOING: 200 Amp.MCCB-3 Nos., 100 Amp.MCCB-1No & 63 Amp.MCCB-1No (as per UPPWD approved make list) 124 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 125 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 126 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only..Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 127 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Grandlay, Gloster, Polycab, Havells, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core (Grandlay, Gloster, Polycab, Havells, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 155 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge.(as per UPPWD approved make list) 156 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 157 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 158 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 159 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 160 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 161 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable) (as per UPPWD approved make list) 163 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to JE store as per direction of E/I.(as per UPPWD approved make list) 164 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 165 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 166 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 167 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work. (as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 170 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 171 Supply & Laying of 6 Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
33.
Health and Family Welfare #9439894 AOC
Tender For Tender For supply of Lab Reagents/Articles And Material. , Item Description , 0.5% Sod. Deoxycholate 250Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved) , 10% Ferric Chloride Reagent. 250Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved) , 10% Koh 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved) , 100 Well Micro Tube Storage Box (For Storage Of 2.0Ml Micro Tubes Or Cryogenic Vials Autoclavable At 121°C 100 Wells Well Dia 1.23 Cm Dimensions 5.6 X 6 X 2.2 Inch 5 Pcs Per Box ) , 2Ml Mct Vial (Sterile) (High-Clarity Polypropylene Graduated In 0.25Ml Increments Easy-Open Caps With Needle Insertion Spot And Textured Marking Area Labeling Area On Tube Exterior Highly Polished Interior For Maximum Sample Recovery Autoclavable At 121°C/15Psi For 15 Minutes Nonpyrogenic Fit All Standard Rotors500 Per Pack) , 8 Channel Variable Volume Micropipette 2-20 Ul (Manually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Should Include Calibration Certificate From Manufacture Large 4 Digit Volume Display Load Multi -Channel Tips Quickly And Securely Without A Need For Rocking. Extremely Consistent Sample Pickup Across All Channels) , 96 Well Reversible Rack For 0.5 To 2.0 Ml Vials (Wells Are Arranged In Standard 8 X 12 Array Alphanumeric Identification Autoclavable Wells: 96 Rack Measures: 9.60L X 4.70W X 2.00H (246Mm X 121Mm X 50Mm) Tubes: 0.5 Ml - Well Dia.: 7.6Mm Tubes:1.5/2Ml - Well Dia.: 11Mm) , Abg Reagent Pack , Absorbent Filter Paper For Shelf 1 To 100 , Acetic Acid. Glacial 500 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Acetic Acid. Glacial 500 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Acetone 2.5 Lit (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Acetone 500 Ml Pack (Nice/Rankam/Qualigens) , Acid Phenol Carbolic 500 Gm. (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Acid Phenol Carbolic 500 Gm. (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Activated Charchol 500Gm (Qualigen/Rankem/Nice) , Ada Kit 1*96 Test (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved.) , Afb Stain 250Ml (Should Be Ivd/Ce/Iso 13485 Certified Co) , Agar Agar Medium 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Agar Sda 500Gm (Should Be Ivd/Ce/Iso 13485 Certified Co) , Agar Sda With Chloramphenicol 500Gm (Should Be Ivd/Ce/Iso 13485 Certified Co) , Ahg 1 X 5Ml (Tulip) , Ahg 1X5ml (J Mitra/Arkray) , Albert Stain (With Albert A & Albert B Both In Kit Ready To Use Liquid Form) 125 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved) , Albumin Liquid Stable Test Kit 5X50 Ml (Erba Transasia) , Albumin Test Kit 100 Ml (Should Be Ivd/Ce/Iso 13485 Certified Co) , Alkaline Peptone Water. 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Alkaline Phosphatase 100 Ml (Meril/Beacon/Agd) , Alkaline Phosphatase Liquid Stable 6X6ml (Erba Transasia) , Amikacin Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Amikacin Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Disc Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Amoxicillin - Clavulanic Acid Antibiotic Disc (6 Mm) 20 / 10 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Amoxicillin - Clavulanic Acid Antibiotic Disc (6 Mm) 20 / 10 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Amoxycillin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ampicillin Antibiotic Disc (6 Mm) 2 188 (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ampicillin Antibiotic Disc (6 Mm) 25 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ampicillin-Sulbactum Antibiotic Disc (6 Mm) (10 Mcg,+10 Mcg), Vial Contain 100 Disc Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Amylase Kit 10 Ml (Meril/Beacon/Agd) , Amylase Kit Liquid Stable 6X6ml (Erba Transasia) , Ana Kit 1*96 Test( Elisa) (Screening Of Quantitative Concentrations Antinuclear Antibodies, Ana Screen Sensitivity (97.0%) Specificity (98.0% Stored At 2 °C - 8 °C Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Ana Kit 1*96 Test (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved.) , Analyser Roll 57 Mm 55 Gsm Top Rated (Should Be Gmp/Ce Certified Company) , Analytic Balance (Weighing Capacity Range: 1Gm.- 1 Kg, Readability 0.1Gm, Pan Size 6 (Approx.) Dual Pans Of Stainlesssteel, Mechanical, Table Top. Standard Weights Should Be Supplied Along With The Analytical Balance.Equipment Quoted Should Comply With Indian Standards Institutions Guidelines Or Any Other National Or International Guidelines.) , Anti A- Lectin/H- Lectin 5Ml (Jmitra/Arkray/Meril) , Anti A- Lectin/H -Lectin 5Ml (Tulip) , Anti A+B+D Igg/Igm +Ab 4X10 Ml (Should Be Ivd/Ce/Iso 13485 Certified Co) , Anti A+B+D With Igg/Igm 12 Ml (Jmitra/Arkray/Meril/Tulip) , Anti Ab 10 Ml (Jmitra/Arkray/Meril/Tulip) , Anti Abd Kit 10 Ml (J Mitra/Arkray/Meril/Tulip) , Anti Ccp Kit 1*96 Test (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved.) , Anti D 1Gg + 1Gm 10 Ml (Tulip/Jmitra/Arkray) , Anti D Igg 10 Ml (Tulip/Jmitra/Arkray) , Anti Sera Salmonella Poly Ah 2 Ml (Ivd Approved/Ce Certified) , Anti Sera Salmonella Poly Dh 2 Ml (Ivd Approved/Ce Certified) , Anti Sera Salmonella Poly H 2 Ml (Ivd Approved/Ce Certified) , Anti Sera Salmonella Poly-O 2 Ml (Ivd Approved/Ce Certified) , Antibiotic Discs - Gn1 (Gn1 - For Gram Negative Isolates/Uti Norfloxacin (Nf/10) Pefloxacin (Pf/5) Cefotaxime (Cx/30) Ceftriaxone (Fr/30) Nalidixic Acid (Na/30) Nitrofurantoin (Fu/300) Cefuroxime (Cr/30) Gentamicin (Gm/10) Amikacin (Ak/30) Ciprofloxacin (Ci/5) Ofloxacin (Of/5) Ceftazidime (Cz/30) Cefixime (Fx/5) Cefdinir (Cn/5) Only Combi Disc With 14 Projecting Arms Each Arm Represents Different Antibiotic / Chemotherapeutic Agent Unique Design With Optimised Antibiotic Concentration, Scientific Auto Cad Disc Architecture And Thoughtful Spacing Of Antibiotics Minimises Overlapping Of Zones Of Inhibition Checks Sensitivity Against 14 Different Antibiotics In A Single Assay Offers Rational Combination Of Most Sought After And Latest Generation Antibiotics Optimum Utilisation Of Media And Space To Achieve Best Results And Economy Proprietary Blocking Agents Used To Prevent Antibiotic Leaching Can Be Conveniently Used With Conventional 85-90 Mm Petri Plate Strict Quality Control Norms Followed According To Clsi Guidelines, Using Standard Atcc Organisms Custom Made (Oem) Combination Of Antibiotics Is Possible) , Antibiotic Discs - Gn2 (Gn2-For Resistant Gram Negative Isolates/Uti Ticarcillin/Clavulanic Acid (Tc/75/2.5) Meropenem (Mr/10) Levofloxacin (Lv/5) Moxifloxacin (Mf/5) Cefprozil (Fp/30) Cefpirome (Ce/30) Ceftizoxime (Fo/30) Cefpodoxime (Co/10) Cefoperazone/Sulbactam (Cs/75/30) Piperacillin/Tazobactam (Pt/100/10) Sparfloxacin (Sp/5) Gatifloxacin (Gf/5) Imipenem/Cilastatin (Is/10/10) Tobramycin (To/10) Only Combi Disc With 14 Projecting Arms Each Arm Represents Different Antibiotic / Chemotherapeutic Agent Unique Design With Optimised Antibiotic Concentration, Scientific Auto Cad Disc Architecture And Thoughtful Spacing Of Antibiotics Minimises Overlapping Of Zones Of Inhibition Checks Sensitivity Against 14 Different Antibiotics In A Single Assay Offers Rational Combination Of Most Sought After And Latest Generation Antibiotics Optimum Utilisation Of Media And Space To Achieve Best Results And Economy Proprietary Blocking Agents Used To Prevent Antibiotic Leaching Can Be Conveniently Used With Conventional 85-90 Mm Petri Plate Strict Quality Control Norms Followed According To Clsi Guidelines, Using Standard Atcc Organisms Custom Made (Oem) Combination Of Antibiotics Is Possible , Antibiotic Discs - Gp1 (Gp1-For Gram Positive Isolates Penicillin (Pg/10) Amoxicillin (Ax/10) Amoxicillin/Clavulanic Acid (Ac/20/10) Co-Trimoxazole (Ct/25) Cephalexin (Cp/30) Cefazolin (Cf/30) Cefuroxime (Cr/30) Erythromycin (Er/15) Chloramphenicol (Ck/30) Ciprofloxacin (Ci/5) Ofloxacin (Of/5) Piperacillin (Pc/100) Azithromycin (Az/15) Tetracycline (Te/30) Only Combi Disc With 14 Projecting Arms Each Arm Represents Different Antibiotic / Chemotherapeutic Agent Unique Design With Optimised Antibiotic Concentration, Scientific Auto Cad Disc Architecture And Thoughtful Spacing Of Antibiotics Minimises Overlapping Of Zones Of Inhibition Checks Sensitivity Against 14 Different Antibiotics In A Single Assay Offers Rational Combination Of Most Sought After And Latest Generation Antibiotics Optimum Utilisation Of Media And Space To Achieve Best Results And Economy Proprietary Blocking Agents Used To Prevent Antibiotic Leaching Can Be Conveniently Used With Conventional 85-90 Mm Petri Plate Strict Quality Control Norms Followed According To Clsi Guidelines, Using Standard Atcc Organisms Custom Made (Oem) Combination Of Antibiotics Is Possible) , Antibiotic Discs - Gp2 (Gp2-For Resistant Gram Positive Isolates Clindamycin (Cm/2) Teicoplanin (Tp/30) Lomefloxacin (Lf/10) Moxifloxacin (Mf/5) Ampicillin/Sulbactam (As/10/10) Cefaclor (Cg/30) Cefadroxil (Cd/30) Roxithromycin ( Ro/30) Clarithromycin (Cl/15) Lincomycin (Ln/15) Sparfloxacin (Sp/5) Gatifloxacin (Gf/5) Linezolid (Li/30) Vancomycin (Vm/30) Only Combi Disc With 14 Projecting Arms Each Arm Represents Different Antibiotic / Chemotherapeutic Agent Unique Design With Optimised Antibiotic Concentration, Scientific Auto Cad Disc Architecture And Thoughtful Spacing Of Antibiotics Minimises Overlapping Of Zones Of Inhibition Checks Sensitivity Against 14 Different Antibiotics In A Single Assay Offers Rational Combination Of Most Sought After And Latest Generation Antibiotics Optimum Utilisation Of Media And Space To Achieve Best Results And Economy Proprietary Blocking Agents Used To Prevent Antibiotic Leaching Can Be Conveniently Used With Conventional 85-90 Mm Petri Plate Strict Quality Control Norms Followed According To Clsi Guidelines, Using Standard Atcc Organisms Custom Made (Oem) Combination Of Antibiotics Is Possible) , Antibiotic Zone Measurement Scale (Should Be Ivd/Ce/Iso 13485 Certified Co) , Anticcp Elisa Kit 1*96 (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Anti-D Sera Vial 10 Ml (Should Be Ivd/Ce/Iso 13485 Certified Co) , Antiseptic Sprey Solution For Safe Phlebotomy 200Ml (Meril/Tulip/Arkrey) , Antisera For Cholera Poly 0 And 0-139 1*10Ml (Ivd Approved/Ce Certified) , Antisera For Salmonella Poly 0,09,02, Hd 1*10Ml (Ivd Approved/Ce Certified) , Aso Kit 50 Ml (Should Be Ivd/Ce/Iso 13485 Certified Co) , Aso Test Card Each (Should Be Ivd/Ce/Iso 13485 Certified Co) , Auramine (C17h22cln3, Mol Wt: 303.84, Dry Powder 250Gm Pack All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners.) , Auromine O 25Gm (Qualigen/Rankem/Nice) , Auto Pipette (10 To 100 Ul) Variable Fully Autoclavable (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Auto Pipette (100 To 1000 Ul) Vaiable Fully Autoclavable (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Auto Pipette (5 To 50 Ul ) Variable Fully Autoclaveable (Sholud Bewhogmp/Fda/Iso13485/Cecertified Co) , Auto Pipette 1Ml To 5Ml Variable Fully Autoclavable (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Azithromycin Antibiotic Disc (6 Mm) (15 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Aztreonam Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Bacitracin Antibiotic Disc (6 Mm) 10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Bacitracin Antibiotic Disc (6 Mm) 10 Units, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Bandaid Water Proof , Bar Code Sticker 50*25 Mm With 78 Gsm Adhesive , Barcode Sticker (Size 50*25) , Baruim Chloride 10% 125 Ml Each Piece , Basic Fuschin (Chemical Name :Pararosaniline Hydrochloride, Chemical Structure: C20h20cln3 Mol Wt:337.86Dye Content: Approx.85%-88%(Dye Content Must Be Mentioned), Colour: Metallic Green.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners.) , Basic Fushion 25Gm (Qualigen/Rankem/Nice) , Beaker 1000 Ml Plastic (Sholud Be Whogmp/Fda/Iso13485/Ce) , Beaker 100Ml Plastic (Sholud Be Whogmp/Fda/Iso13485/Ce) , Beaker 2000 Ml Plastic (Sholud Be Whogmp/Fda/Iso13485/Ce) , Beaker 250 Ml Plastic (Sholud Be Whogmp/Fda/Iso13485/Ce) , Beaker 500 Ml Plastic (Sholud Be Whogmp/Fda/Iso13485/Ce) , Bile Broth (Adult) 50Ml Each (Should Be Ivd/Ce/Iso13485 Certified) , Bilirubin Kit (Total & Direct) 200 Ml (Meril/Beacon/Siemens) , Bilirubin Kit (Total & Direct) 4 X 60 Ml (Erba Transasia) , Biohazard Autoclavable Bag Yellow/Clear 12X24 (Whogmp/Fda/Iso13485/Ce Certified Co) , Biohazard Autoclavable Bag Yellow/Clear 24X36 (Whogmp/Fda/Iso13485/Cecertified Co) , Biohazard Dustbin Foot Operated 20 Ltr Blue/Black/Green/Yellow/Red (Should Be Iso9001:2015) , Biohazard Dustbin Foot Operated 30 Ltr Blue/Black/Green/Yellow/Red (Should Be Iso9001:2015) , Biohazard Dustbin Foot Operated 45 Ltr Blue/Black/Green/Yellow/Red (Should Be Iso9001:2015) , Biological Indicator , Biomedical Waste Bag (Red, Black, Yellow, Blue Colour) (Per Kg) , Biorad Internal And External Quality Controls , Bleaching Powder 500Gm (Should Be Iso13485/Iso Certified Co) , Block Cabinet Almirah 10000 Quantity , Blood Bag Double Sagem 450Ml (Polymed) , Blood Bag Double Sagem 450Ml (Jmitra) , Blood Bag Paedtric 100Ml (Jmitra/Polymed) , Blood Bag Single 350/450Ml (Polymed) , Blood Bag Single 350/450Ml (Jmitra) , Blood Bag Triple 450Ml (Segam) (J Mitra) , Blood Bag Triple 450Ml Segam (Polymed) , Blood Culture Bot Carbon Dioxide Sensor Mounted Adult (Should Be Ivd/Ce/Iso13485 Certified) , Blood Culture Bot Carbon Dioxide Sensor Mounted Paed. (Should Be Ivd/Ce/Iso13485 Certified) , Blood Culture Bottles (Bhi) Adult (Should Be Ivd/Ce/Iso13485 Certified) , Blood Culture Bottles (Bhi) Paed. (Should Be Ivd/Ce/Iso13485 Certified) , Blood Glucose Kit Powder 2 X 200Ml (Erba Transasia) , Blood Glucose Kit 250 Ml (Meril/Beacon/Agd) , Blood Mixer 360 Degree Inversion Technology Digital Display (Should Be Iso13485/Iso9001-2015) , Blood Urea Kit (20Ml Pack)100Ml Kit (Meril/Beacon/Agd) , Blood Urea Kit Powder 5 X 20Ml (Erba Transasia) , Blotting Paper , Blue Nitrile Gloves (Medium.Rnase Free Dnase Free. Powder Free ,Latex Free Superior Quality, Ce/Iso 13485 Certified Single Use 50Pairs Per Box) , Bold Permanent Marker (Black) , Bovine Albumin 10Ml (J Mitra/Tulip/Meril) , Brilliant Cresyl Blue (Should Be Ivd/Ce/Iso13485 Certified) , Broom Sticks , Broth Selenite F 500Gm (Should Be Ivd/Ce/Iso13485 Certified) , Brown Tape (Size 1 Inch 66 M) , Brush For Washing Test Tube 1X 1 (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Bunsen Burner , Bunsen Burner (Fast Flame Bunsen Burner Stainless Steel, For Use With Natural And Cylinder Gases, 15Cms Height, Head Diameter 13 Mm, Nickel Plated With Stopcock.) , Butterfly Needles - 21G (With 300Mm Length Tubing Winged Infusion Set Used For Accessing A Superficial Vein For Either Intravenous Injection Or Phlebotomy) , Butterfly Needles - 23G (With 300Mm Length Tubing Winged Infusion Set Used For Accessing A Superficial Vein For Either Intravenous Injection Or Phlebotomy) , Butterfly Needles - 25G (With 300Mm Length Tubing 25 -Should Have Extention Set Which Is 1000Mm Long Winged Infusion Set Used For Accessing A Superficial Vein For Either Intravenous Injection Or Phlebotomy) , Calcium Arsenazo 2X50ml (Erba Transasia) , Calcium Arsenazo 50 Ml (Meril/Beacon/Agd) , Cap For Plastic Tube 12X75 (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Capillary Tube (Sholud Be Whogmp/Fda/Iso13485/Cecertified Co) , Carbol Fuchsin Stain 25Gm ( Nice/Rankam/Qualigens) , Carbol Fuschin 125Ml (Should Be Iso13485/Iso9001- 2015Certified Co) , Carbol Fuschin Stain 125 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Carbolic Acid (Phenol) Crystals (Chemical Name: Phenol, Chemical Structure: C6h5oh, Molecular Wt:94.11, Melting Point:40 °C +2, Purity:99.5% All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners.) , Carbolic Acid (Phenol) Liquid (Chemical Name: Phenol, Chemical Structure: C6h5oh, Molecular Wt:94.11, Purity:99.5% All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners.) , Cedar Wood Oil 1*500Ml , Ceder Wood Oil 25Ml (Nice/Merck/Rankem) , Cefaclor Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefazolin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefdinir Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefdinir Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefepime Antibiotic Disc (6 Mm) (30 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefixime Antibiotic Disc (6 Mm) (5 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefoperazone + Sulbactum Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefoperazone 75 + Sulbactum 30 Mcg (6 Mm) Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefoperazone Antibiotic Disc (6 Mm) (75 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefotaxime Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefotaxime Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefotriaxone + Salbactum Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefoxitin Antibiotic Disc (6 Mm) , Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftaroline Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftazidime +Clavulanic Acid Antibiotic Disc (6 Mm) (30/10 ?Cg) Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftazidime Antibiotic Disc (6 Mm) (30 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftobiprole Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftriaxone + Sulbactum Antibiotic Disc (6 Mm) Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftriaxone + Sulbactum Pack Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Equired Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ceftriaxone Antibiotic Disc (6 Mm) (5 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cefuroxime Antibiotic Disc (6 Mm) (30 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cell Clean 50Ml (Sysmex) , Cell Pack 20Ltr (Sysmex) , Centrifuge Machine Bushless With Rotor Head 8X15ml 4400Rpm (Iso9001-2008 4400 Digital Timer) , Cephalexin Antibiotic Disc (6 Mm) (30 Mcg), Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cephalothin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Chemical Sterilization Indicators (Stickers) (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Chikunguniya Rapid Card Test (Should Be Rapid 3 Band Test Should Detect Igg/Igm Antigen It Should Be Lateral Flow Through Assay Format It Should Have Ready To Use Conjugate System Assay Time Should Be Of 15Mins Type Of Sample For Test Should Be Serum/Plasma/Whole Blood 10Ul Of Sample Is Required For The Test Sensitivity Should Be 100% Specificity 98% Storage Temperature 2-40C Ivd Approved Validity:24 Months,Should Be Usfda Approved/Euand Ce Marked /Ivd Approved.) , Chloramphenicol Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Chloramphenicol Antibiotic Disc (6 Mm) 30 Mcg,Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor 208 (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cholestrol Kit 100Ml Kit (Meril/Beacon/Agd) , Cholestrol Kit Powder 5 X 20Ml (Erba Transasia) , Chopping Board ( Grossing) , Christensens Urea Agar. 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Ciprofloxacin Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Ciprofloxacin Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cleaning Acid 1 X 5 Ltr (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Cled Agar 500Gm (Should Be Ivd/Ce/Iso13485 Certified) , Columbia Agar + 5% Sheep Blood (90 Mm Stacker Plates) (Isolation Of Fastidious Bacteria. Detection Of Hemolysis Pack Of 20 Should Be Compatible To Biomerieux Microbiological Instruments (90 Mm Stacker Plates) Specimens Are As Follows :- Blood Culture Bronchoalveolar Lavage Cerebro Spinal Fluid Endotracheal Aspiration Fecal Specimen Genital Specimen Perinatal Infection Specimen Screening Swab Sputum Upper Respiratory Swab Urine Should Be Iso 9001:2015 Certified There Should No Evidence Of Microbial Contamination, Discoloration, Drying, Cracking Or Other Signs Of Deterioration. On Inoculation It Should Represent Samples With The Following Strains:- Should Show Excellent Growth Of Streptococcus Pyogenes Atcc 19615 Should Show Excellent Growth Of Streptococcus Pneumoniae Atcc 6305 Should Show Excellent Growth Of Staphylococcus Aureus Atcc 25923 Should Show Excellent Growth Of Escherichiacoli Atcc 8739) , Conical Flask Borosilicate Glass 1000Ml (Sholud Be Whogmp/Fda/Iso13485/Ce) , Conical Flask Borosilicate Glass 250Ml (Sholud Be Whogmp/Fda/Iso13485/Ce) , Conical Flask Borosilicate Glass 500Ml (Sholud Be Whogmp/Fda/Iso13485/Ce) , Cooked M Medium (R.C Medium) 500G (Should Be Ce/Iso13485 Cetfied Company) , Coplin Jar (Sholud Be Whogmp/Fda/Iso13485/Ce) , Cotrimoxazole Antibiotic Disc (6 Mm) 25 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cotrimoxazole Antibiotic Disc (6 Mm) 25 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Cover Slips Large (22X22 Mm) Blustar (Blustar) , Cover Slips Large (22X50 Mm) Bluestar (Blustar) , Cover Slips Small (18X18 Mm) Blustar (Blustar) , Creatinine Test Kit 100 Ml Kit (Meril/Beacon/Agd) , Creatinine Test Kit 4 X 60Ml (Erba Transasia) , Crp Kit (Creactive Protein) Kit (Quantitative) 1X40/1X10ml 50 Ml (Meril/Beacon/Agd) , Crp Kit (C-Reactiveprotein) Kit (Qualitative) Slidemethod 35 Test (Tulip/Arkray) , Crp Kit C-Reactive Protein) Kit (Qualitative) Slidemethod 50 Test (Should Be Ce/Iso13485 Cetfied Company) , Crp Kittltx (C-Reac Protein) Kit 1X40/1X10ml(Quantitative) (Erba Transasia) , Crp Rapid Card (Tulip/Meril/Beacon) , Cryo Vial Sterile 1.8Ml (Sholud Be Whogmp/Fda/Iso13485/Ce ) , Crystal Violet Stain 125 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Crystal Voilet Stain 125Ml (Should Be Iso13485/Iso9001-2015 Certified Co) , Culture Media With Sensitivity Disk As Per Requirement Gram(+)Gram(-) Higher , Cushion Ball , Cuvettes And Stirrers For Haemoster , Cuvettes For Pti Test , Cyto Brush Kit , D M Water 5Ltr (Nice/Rankam/Qualigens) , Dca Agar 500 Gm , Dengue Rapid Card 1*25 (Should Be Rapid Test Should Detect Ns1/Igg/Igm Antigen It Should Be Lateral Flow Through Assay Format It Should Have Ready To Use Conjugate System Assay Time Should Be Of 15Mins Type Of Sample For Test Should Be Serum/Plasma/Whole Blood 20Ul -100Ul Of Sample Is Required For The Test Sensitivity 98%Specificity99% Storage Temperature 2-40C Ivd Approved Validity:24 Months Should Be Usfda Pproved/Euand Cemarked /Ivd Approved) , Dengue Igg Elisa (Generation Of Test Should Be Early Elisa It Should Be Elisa Assay Format Assay Time Should Be Of 90 Mins It Should Have Ready To Use Conjugate System Type Of Sample For Test Should Be Serum/Plasma Sensitivity 99% Specificity 99% Storage Temperature 2-8C Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved.) , Dengue Igm Elisa (Generation Of Test Should Be Early Elisa It Should Be Elisa Assay Format Assay Time Should Be Of 90 Mins It Should Have Ready To Use Conjugate System Type Of Sample For Test Should Be Serum/Plasma Sensitivity 99% Specificity 99% Storage Temperature 2-8C Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved.) , Deproteiniser 50Ml Agd (Agd) , Dettol Soap 125 Gm , D-Glucose Anhydrous 500 Gm , Diamond Pencil For Glass Slides Marking (6 (15.24 Cm.) Holder With Artificial Diamond (Hard Stone) Embedded At One End With Screw Cap, To Mark On Glass Slides.) , Digita Room Thermometers With Humidity Indicator 1*1 , Digital Thermometers For Incubators/Refrigerators 1*1 , Dimethylaminobenzaldehyde (Para-Dimethylaminobenzaldehyde Is An Organic Compound Containing Amine And Aldehyde Moieties Which Is Used In Ehrlichs Reagent And Kovacs Reagent To Test For Indoles. The Carbonyl Group Typically Reacts With The Electron Rich 2-Position Of The Indole But May Also React At The C-3 Or N-1 Positions.Molar Mass: 149.19 G/Mol, Formula: C9h11no, Boiling Point: 310 °C, Density: 1.1 G/Ml, Melting Point: 74 °C (165 °F; 347 K), Solubility In Water: 0.3 G/L) , Di-Potassium Hydrogn Orthophosphate 500 Gm (Nice/Rankam/Qualigens) , Direct Hdl Kit 4X30ml/4X10ml (Erba Transasia) , Direct Hdl Kit 50 Ml (Should Be Ce/Iso13485 Cetfied Company) , Disinfactant Soln For Surgical (Silver Nitrate 1% +Hydrogen Peroxide 6%, 1 Litre Pack) (Should Be Whogmp/Fda/Iso13485/Ce Certified) , Di-Sodium Hydrogenorthophosphate Anhydrous 500Gm (Should Be Whogmp/Fda/Iso13486/Ce Certified ) , Disposable Droper 1.0Ml (Should Be Whogmp/Fda/Iso13485/Ce Certified Co) , Disposable Droper 3.0Ml (Should Be Whogmp/Fda/Iso13485/Ce Certified Co) , Disposable Needle 20 No. (Bd/Dispovan/Romson) , Disposable Needle 21 No. (Bd/Dispovan/Romson) , Disposable Needle 22 No. (Bd/Dispovan/Romson) , Disposable Needle 23 No. 1.5 Inch (Bd/Dispovan/Romson) , Disposable Needle 26 No. (Bd/Dispovan/Romson) , Disposable Syringe 1 Ml With 26 No. Needle (Bd/Dispovan/Romson) , Disposable Syringe 10 Ml With 22 No. Needle (Bd/Dispovan/Romson) , Disposable Syringe 5Ml With 21 No. Needle (Bd/Dispovan/Romson) , Disposable Syringe 5Ml With 22 No. Needle (Bd/Dispovan/Romson) , Disposal Cap (22 Inch) , Disposal Shoe Cover , Distill Water 1*5Ltr , Doa Insight Six In One (Tulip) , Doxycycline Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Dpx Mount 100 Ml (Should Be Ivd/Ce/Iso13485 Certified) , Dpx Mount 250 Ml (Qualigen/Rankem/Nice) , Drabkin Solution 1000 Ml (Arkray) , Drabkin Solution 5 Litre (Arkray) , Draining Basket Big (Should Be Whogmp/Fda/Iso13485/Ce Certified Co) , Draining Basket Small (Should Be Whogmp/Fda/Iso13485/Ce Certified Co) , Draining Tray Big (Should Be Whogmp/Fda/Iso13485/Ce Certified Co) , Drinking Water - H2s Test Strip Bacterial Test 1 To 10 , Droping Bottle 125Ml (Should Be Whogmp/Fda/Iso13485/Ce) , Dropper (Plastic) (Sholud Be Whogmp/Fda/Is13485/Ce Ce) , Dropper Bottles (250Ml Capacity Built-In Stem All Polypropylene; Leak Proof Screw Cap Made Of Polypropylene) , Drying Racks (Stainless Steel, To Drain Microscope Slides After Staining, Each Rack To Accommodate At Least 16 Slides, Approximate Dimensions 350 X 180 X 5 Mm.) , Durham Tube (Should Be Whogmp/Fda/Is13485/Ce Ce) , E.C.G. Battery (Allenger) , E.C.G. Battery 6108 , E.C.G. Battery 6208 , E.C.G. Bulb , E.C.G. Cable Complete , E.C.G. Roll (5 Channel) (Should Be Ce/ Iso 13485/Iso9001-2015) , E.C.G. Roll 6108 (Should Be Ce/ Iso 13485/Iso9001-2015) , E.C.G. Roll 6208 (Should Be Ce/ Iso 13485/Iso9001-2015) , Ea 36 Stain 125Ml , Ecg A4 Sheet Edan 210Mmx295mm (Should Be Ce/ Iso 13485/Iso9001-2015) , Ecg Jelly 250Ml Bottle (Should Be Ce/ Iso 13485/Iso9001-2015) , Electrolyte Cleaning Sol Pack 6X15mldiagnoquip (Diagno) , Electrolyte Pack Diagnoquip 800Ml (Diagno) , Electronic Balance (General Purpose Table Top Laboratory Balance,Stainless Steel, 220-230 V, Stainless Steel Platform,Keypad Auto Calibration Function, Auto Off, Battery Life Of At Least Three Months After Installation, Overload Of At Least Three Months After Installation, Overload And Under Load, Low Battery Lcd/Led Indicator.Range: Wide Range: 0.001 - 120 Gms, (Three Digit Decimal), Resolution: 0.001 Gms, Accuracy 0.001Gm, Repeatability (Sd): 0.01 Gm., Pan Diameter 80Mm., Weighing Pan Enclosed In Glass Shield ,With Full Range Tare, Ac Adapter.Equipment Quoted Should Comply With Indianstandards Institutions Guidelines Or Any Othernational Or International Guidelines. Voltageregulator Of Appropriaterating To Be Included To Cope 160 - 260 V.) , Elisa Afp (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Ca-125 (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Cea (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Folic Acid (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Fsh (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Elisa Ft3 (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma , Elisa Ft4 (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/ European Ce Marked /Ivd Approved. , Elisa Igm Chikunguniya Kit 1X96 Type Of Sample For Test Should Be Serum/Plasma With Controls Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Elisa Lh (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma. Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Elisa Progestrone (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Prolactin Assay (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Elisa Serum Ferritin (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa T3 (1 X 96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/ European Ce Marked /Ivd Approved. , Elisa T4 (1 X 96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Testosterone (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Total Hcg (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Tpo (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Tsh (1 X 96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Elisa Vit B12 (1*96 Test) Quantitative Detection Of Vitamin B12 (Cyanocobalamin) In Human Serum Linearity Range: 50- 2000 Pg/Ml Analytical Sensitivity: 50 Pg/Ml Approved By Drug Controller General Of India (Dcgi),Ivd Break-Away Micro Well Strips , Eosin Stain 125 Ml Each Pack (Should Be Iso13485/Iso9001-2015 Comp) , Eosin Yellow Ms Water Soluble Powder 25Gm (Nice/Qualigen/Rankam/Merck) , Eppendorfs (1Ml) 1*1 , Erba. Lipase Test Pack 1X20/1X5 Ml (Transasia) , Erba. Norm 1 X 5Ml (Transasia) , Erba. Norm 4 X 5Ml (Transasia) , Erba. Path 1 X 5Ml (Transasia) , Erba. Path 4 X 5Ml (Transasia) , Erba. Wash 4 X 50 Ml (Transasia) , Erythromycin Antibiotic Disc (6 Mm) 15 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Erythromycin Antibiotic Disc (6 Mm) 15 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Esculine Media 500 Gm (Should Be Ce/Iso13485 Cetfied Company) , Esr Disposable Tube (Levram/Jk/Helico) , Esr Stand For Disposable Pipetter (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Esr Stand Screw Type (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Esr Tube Marienfield Germany Glass Tube 300Mm (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Estradiol Elisa (1*96 Test) Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Ethanol (70% V/V Ip) Contains 0.5% W/V Benzalkonium Chloride (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Ethanol 500Ml For Lab Use (Qualigen/Rankem/Merck) , Examination Gloves Small/Medium/Large (Should Be /Ce/Iso13485 Certified) , Exercise Ball , Extraction Kit Automated Viral Dna Extraction Kit 96 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , Extraction Kit Automated Viral Rna Extraction Kit96 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , Extraction Kit Qia Annual Periodical Maintenance Elute Virus Spin Kit 50 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , Extraction Kit Qia Mini Elute Virus Spin Kit 50 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , Extraction Kit Qia Mp Viral Rna Mini Kit 250 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , Extracton Kit Qia Annual Periodical Maintenance Viral Dna Blood Mini Kit 250 Test (Should Be Iso13485/Iso9001-2015 Certified Co) , F 200 B-Hcg Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Ckmb Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Crp Qntitatative Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 D Dimer Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Dengue Igm/Igg Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Hba1c Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Microalbumin Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Pct Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 T4 Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Trop I Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Tsh Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , F 200 Vit D3 Test Kit Each (Should Be Ivd/Ce/Iso13485 Certified) , Falcon Tubes (Tube Conical Bottom Sterile) Material- Polypropylene, Capacity-50 Ml Shatter Resistant Conical Bottom Tube ,Cap Type-Reclosable Screwed Hinged Type,Tubes Can With Stand Upto 3500Rpm, Ultra Centrifugable Type, Certifications-Ce/Iso. , Falcon Tubes (Tube Conical Bottom Sterile) Material- Polypropylene, Capacity-15 Ml Shatter Resistant Conical Bottom Tube ,Cap Type-Reclosable Screwed Hinged Type,Tubes Can With Stand Upto 3500Rpm, Ultra Centrifugable Type, Certifications-Ce/Iso. , Fdp Kit , Ferritin Kits Assay Type Sandwich-Elisaformat 96T/48T Assay Time 3.5Hdetection Range 0.16-10 Ng/Ml Sensitivity 0.10 Ng/Mlsample Type &Sample Volume Serum, Plasma And Other Biological Fluids; 100?L Specificity This Kit Recognizes Human Fe In Samples. No Significant Cross-Reactivity Or Interference Between Human Fe And Analogues Was Observed. Reproducibility Both Intra-Cv And Inter-Cv Are 10%. This Elisa Kit Applies To The In Vitro Quantitative Determination Of Human Fe Concentrations In Serum, Plasma And Other Biological Fluids. , Filariasis Antigenshould Be Rapid Test Should Detect Antigen It Should Be Lateral Flow Through Assay Format It Should Have Ready To Use Conjugate System Assay Time Should Be Of 15Mins Type Of Sample For Test Should Be Serum/Plasma/Whole Blood 10Ul Of Sample Is Required For The Test Sensitivity Should Be 100% Specificity 100% Storage Temperature 2-40C Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Filter Paper N 4 Whatman 46*57 Cms 100 Sheet Per Box , Filter Paper No 1 Whatman , Filter Paper Whatman No. 1 1 Box , Fobt Card (Occult Blood Test) (Tulip/Jmitra/Meril) , Fogging Soln (Acetyl Dimethyl Benzyol Chloride 2.37And Alkyl Dimethyl Ethyl Amonium Chloride 2.27, 1 Lite (Should Be Ivd/Ce/Iso13485 Certified) , Forceps Plain 1*1 , Formaldehyde Sloution 500 Ml (Should Be Ivd/Ce/Iso13485 Certified) , Formalin 37-41% 5 Litre (Qualigen/Rankem/Nice) , Formic Acid 250 Ml (Should Be Iso13485/Iso9001-2015 Certified Co) , Fosfomycin Antibiotic Disc (6 Mm) 300 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Fosfomycin Antibiotic Disc (6 Mm) 300 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Frosted Micro Slides (Should Be Iso9001:2008 Certified) , Fructose 500 Gm. (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Funnel Glass 60Mm Diameter Borosilicate , Funnel Stand Iron , Funnel Stand Steel , G6pd (Manual) (Should Be Dcgi Approved/European Ce Marked /Ivd Approved.) , G6pd Test 5 Test (Should Be Ivd/Ce/Iso13485 Certified) , Gamma Ggt Test 20 Ml (Meril/Beacon/Siemens) , Gamma Ggt Test 5 X 6 Ml . (Erba Transasia) , Geimsa Stain 125Ml (Should Be Iso13485/Iso9001-2019 Certified Co) , Gelpack 300Ml , Gentamicin Antibiotic Disc (6 Mm) 30 Mcg,Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Glacial Acetic Acid 500Ml (Qualigen/Rankem/Nice) , Glass Beakers (Glass ,Autoclavable & Heat Resistant , Capacity 100Ml. ) , Glass Beakers (Beakers Glass ,Autoclavable & Heat Resistant , Capacity 500Ml.) , Glass Beakers (Beakers Glass ,Autoclavable & Heat Resistant , Capacity 1000Ml.) , Glass Condenser Tube 3 Feet Length With 5Mm Inside Diameter (Borosilicate) , Glass Flask 5 Liters Borosilicate (Borosil) , Glass Slide Box 50 Pieces Pack Blustar (Blustar) , Glass Slide Frosted (Size:75 Mm X 25 Mm ± 1Mm Thickness: 1Mm- 1.2 Mm ± 0.1Mm Frosted One End One Side Ground Edges With Interlink Paper Vaccum Packed Made Of Scratch Resistant Clear Glass Slides Should Be Cleaned And Ready To Use) , Glass Slides (Glass Slides Plain, Size = 76Mm X 26Mm X 1.3Mm, Clean, Scratch Free With Smooth Edges, Uniform,Refractive Index, Pack Of 50.) , Glucometer Strips (Dr. Morephen) , Glucometer Strips Gdh-Fad Method With Single Packing Of Strip (Accusure) , Glucose 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Glucose Broth Vegetable Peptone Based Medium (500 Gms) (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Glutraldehyde Solution 2.5% , 1 Litre Pack (Should Be Iso13485/Iso9001-2015 Certified Co) , Glycerol 500Ml (Should Be Iso13485/Iso9001-2016 Certified Co) , Gms Stain 125 Ml (Should Be Iso13485/Iso9001-2017 Certified Co) , Gomosis Methanammi Stain For Fungus , Gram Negative Broth 250Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Gram Staining Kit 100*4 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Grams Iodine 1% 100 Mlshould Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Grams Iodine 125 Ml (Should Be Iso13485/Iso9001-2018 Certified Co) , H&E Stain 125 Ml (Should Be Iso13485/Iso9001-2015 Certified Co) , H2so4 Acid (Concentrated) Cane Of 1 Ltr (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Haemopipette Tube 1 X 200 (Sholud Be Whogmp/Fda/Iso13485/Ce Certified Co) , Hb Meter Digital (Should Be Ce/Iso13485 Cetfied Company) , Hb Meter Imported (German) , Hb Meter Strip Type (Tulip) , Hb Meter Strip Type (Accusure) , Hb Meter Strip Type (Truehb) , Hb Pipette (German) , Hb Pipette Imported (German) , Hb Strip (Tulip/Accusure/Truehb) , Hb Tube Imported (German) , Hba1c Cardvector (Should Be Ivd/Ce/Iso13485 Certified) , Hba1c Kit (Immunostubimetric Method) (Erba Transasia) , Hbs Ag Immuno-Choromatographic Strip Single Test (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved.) , Hbsag Card (Tulip/Jmitra/Arkray/Meril) , Hbsag Card Extra Senstive (0.3Ng Senstivity) (Tulip/Jmitra/Arkray/Meril) , Hbsag Elisa 96 Test (Third Generation) (Jmitra/Tulip/Meril/Erba) , Hbsag Rapid 1*25 (It Should Be Lateral Flow Through Assay Format Assay Time Should Be Of 10Mins It Should Be Single Step Test Type Of Sample For Test Should Be Serum/Plasma 10Ul-50Ul Of Sample Is Required For The Test Sensitivity Should Be 100% Specificity Of The Kit Is 98.5% Storage Temperature 2-40C Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved , Hbv Rt Pcr Kit (Per Test Rates To Be Quoted) (In Vitro Nucleic Acid Amplification Test For The Quantitation Of Hepatitis B Virus (Hbv) Dna In Human Edta Plasma/Serum.The Kit Should Offer An Open System Testing And Be All-Inclusive Containing Quantification Standards, Master Mix, Primers, Probe, Nuclease-Free Water Etc.The Kit Should Contain Universal Heterologous Preferably Endogeneous Internal Control To Verify Sample Quality, Extraction Quality, And Pcr Inhibition ,The Limit Of Detection, Specificity And Sensitivity Of The Kit Should Be Mentioned In The Kit Insert And Supported With The Required Data. Analytical Sensitivity Should Be More Or Equal To 2 Iu/Ml, Supplier Should Have Field Application And 24 X 7 Online Support Facility, Kit Should Detect Genotypes A-H And Pre-Core Mutants,Kit Should Be Ivd Approved /Cdsco Approved And Licensed By Dcgi(I).) , Hcg Elisa1*96 (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Hcl Acid , Hcv & Hiv Card 2 In One Card (Should Be Ivd/Ce/Iso13485 Certified) , Hcv Card Test (Tulip/Arkray/Meril) , Hcv Elisa 96 Test (Third Generation) (Jmitra/Tulip/Meril) , Hcv Rt Pcr Kit (Per Test Rates To Be Quoted) (In Vitro Nucleic Acid Amplification Test For The Quantitation Of Hepatitis C Virus (Hcv) Rna In Human Edta Plasma/Serum.The Kit Should Offer An Open System Testing And Be All-Inclusive Containing Quantification Standards, Master Mix, Primers, Probe, Nuclease-Free Water Etc.The Kit Should Contain Universal Heterologous Preferably Endogeneous Internal Control To Verify Sample Quality, Extraction Quality, And Pcr Inhibition ,The Limit Of Detection, Specificity And Sensitivity Of The Kit Should Be Mentioned In The Kit Insert And Supported With The Required Data. Analytical Sensitivity Should Be More Or Equal To 20 Iu/Ml,Supplier Should Have Field Application And 24 X 7 Online Support Facility, Kit Should Be Able To Detect And Quantify Hcv Rna, Genotype 1 - 6,Kit Should Be Ivd Approved /Cdsco Approved And Licensed By Dcgi(I).) , Hcv Triodot Card Flowthrough (J.Mitra/Meril/Arkray) , Hcv/Hiv/Hbsag/Syphilis Card 4 Test In One Card (Should Be Ivd/Ce/Iso13485 Certified) , Hdl Kit 2 X 50Ml (Should Be Ivd/Ce/Iso13485 Certified) , Hematoxylin Harris Stain 125 Ml Each Pack (Nice/Rankam/Qualigens) , Hepatits -B Test Elisa 1*96 (Sensitivity: 100% -Specificity: 100% -Longer Shelf Life: 24 Months At 2-8°C -Approved By Drug Controller General Of India (Dcgi) ,Ivd For The Usage In Blood Banks-Detects (Hbsag) Of All The 11 Subtypes And Mutant Strains-Assay Procedure Should Not More Than 120 Mins-Break-Away Micro Well Strips-Antigen Sensitivity-0.1Ng/Ml.) , Hepatits -C Rapid Test 1*50 (It Should Be Lateral Flow Through Assay Format Assay Time Should Be Of 10Mins It Should Be Single Step Test Type Of Sample For Test Should Be Serum/Plasma/Whole Blood 10Ul Of Sample Is Required For The Test Sensitivity Should Be100 % Specificity Of The Kitis 98.5% Storage Temperature 2-40C Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved Should Be 3Rd Generation Should Detect Ns3,Ns4,Ns5 Antibodies Should Use Recombinant Type Antigen) , Hepatits -C Test Elisa 1*96 (Sensitivity: 100% -Specificity: 100% -Longer Shelf Life: 24 Months At 2-8°C -Approved By Drug Controller General Of India (Dcgi) For The Usage In Blood Banks -3Rd Generation Assay -Unique Combination Of Hcv Antigens For E1, E2, Core, Ns3, Ns4 & Ns5 -Assay Procedure Should Not More Than 120 Mins -Break-Away Micro Well Strips) , Hiv 1/2 Card (Tulip/Arkray/Meril) , Hiv 96 Test Elisa 4Th Generation (J Mitra/Tulip/Erba/Meril) , Hiv Card Retroquic Flow Through Method (Should Be Ivd/Ce/Iso13485 Certified) , Hiv Elisa 96 Test (Should Be Ivd/Ce/Iso13485 Certified) , Hiv Tridot Card Flow Through Method (J.Mitra/Meril/Arkray/Tulip) , Hme Filter , Hot Air Oven Digital Display Both Side Ss 304 18X18 (Should Be Ce/Iso13485 Certified) , Human Ama-M2 Elisa Kit (Quantitative Concentrations Of Igg Auto Antibodies Against Mitochondrial M2 Sub Type Antigen (Anti-Mitochondrial Antibodies), Ama-M2 Sensitivity (97.0%) Specificity (94.0%) Stored At 2 °C - 8 °C Approved By Drug Controller General Of India (Dcgi)) , Hvs Sterile Swab Sticks (Should Be Ivd/Ce/Iso13485 Certified) , Hydochloric Acid 5 Litre (Qualigen/Rankem/Nice) , Hydrochloric Acid (Concentrated Hydro Chloric Acid, Molecular Wt: 36.46 Specific Gravity 1.18, 15 Liter.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners.) , Hydrochloric Acid N/10 500Ml (Qualigen/Rankem/Nice) , Hydrochloride Acid (Conc.) 500 Ml (Qualigen/Rankem/Nice) , Hydrogen Peroxide 3% Reagent 500 Ml (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Hydrogen Peroxide 3% , Hydrogen Peroxide 3% Reagent 125 Ml (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Igm Hepatits -A Test Elisa 1*96 (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/Euand Ce Marked /Ivd Approved) , Igm Hepatits -A Test Rapid 1*25 (Should Be Usfda Approved/Euand Ce Marked /Ivd Approved) , Igm Hepatits -E Rapid Test 1*10 (Type Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/Euand Ce Marked /Ivd Approved) , Igm Hepatits -E Test Elisa 1*96 (Should Be Usfda Approved/Euand Ce Marked /Ivd Approved) , Igm Je Elisa Kit( Japanies Encephalaties) 1 X96 (Should Be Usfda Approved/Euand Ce Marked /Ivd Approved Type Of Sample For Test Should Be Serum/Plasma) , Igm Measles Elisa 96 Test (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Igm/Igg Leptospira Test Card (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Imipenem Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Immersion Oil 250 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Immersion Oil Microscope 25Ml (Nice/Merck/Rankem) , Immersion Oil Microscope 30Ml (Should Be Ce/Iso13485 Certified) , Incubator Digital Display Both Side Ss 304 18X18 (Should Be Ce/Iso13485 Certified) , India Ink For Cryptococus , Indicator Tape For Sterilization (Should Be Ivd/Ce/Iso13485 Certified) , Individual Pcr Tube 8 Tube Strip Clear (Should Be Ce/Iso13485 Certified) , Inoculating Loop Disposable Sterile (Should Be Ivd/Ce/Iso13485 Certified) , Inoculating Loop Nichrome Wire 2Mm (Should Be Ce/Iso13485 Certified) , Inoculating Loop Nichrome Wire 4Mm (Should Be Ivd/Ce/Iso13485 Certified) , Insulin Syringe (Bd/Romson/Dispovan) , Internal/External Quality Control 5Ml Each (Should Be Ce/Iso13485 Certified) , Iodine - 125 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Ise Pack Erma Agd 620Ml (Agd) , Isopropyl Alcohal Based Hand Wash Solution 500Ml , Isopropyl Solution 500Ml (Qualigen/Rankem/Nice) , Isopropyle Alcohal 2.5 Ltr 70% (Qualigen/Rankem/Nice) , Isopropyle Alcohol Absolute 2.5 Litre (Qualigen/Rankem/Nice) , Kanamycin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Keto Dia Stix (Strip Test 1 X 100 Strips)/50 Strips , Kit For Detection Of Occult Blood In Stool 200 Test (Card Test 1 X 50) (Should Be Usfda Approved/European Ce Marked /Ivd Approved.) , Knife Big (For Grossing) , Kovac Indole Regent 100Ml (Should Be Ivd/Ce/Iso13485 Certified) , Kovacs Indole Reagent Ready To Use Liquid Form (100 Ml) (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Lactose 500 Gm (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Lancet For Glucometer (Should Be Iso13485/Iso9001-2015 Certified Co) , Lead Acetate Strips. 1 X 100 (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Led Vein Finder (Continuous Run Time 5 Hours. 5 Adjustable Brightness Degree.5 Color Mode. Inverse Mode. Enhance/Fine Mode. Stand-By Mode.Depth Mode.Vein Image Storage And Export.Usb Port For Data Transfer.Auto Wakes Up Function.Distance Sensor And Hint. Vein Image Center Guild.Should Be Usfda Approved.) , Leishman Stain 250 Ml (Should Be Ivd/Ce/Iso13485 Certified) , Leishman Stain Liq 250 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Leishmaniasis Rapid Test (Should Be Ivd/ Ce/Iso13485 Certified Co) , Lens Cleaning Paper 1X25 Whatman (Whatman) , Lens Paper (Soft Microscope Lens Cleaning Tissue, 4 X 6 Booklet, Each Booklet Containing 100 Sheets.) , Leptospira Test Elisa Kit 1*96 (Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved.) , Levofloxacin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Linezolid Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensor (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Linezolid Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Disc (Filter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved.) , Lipase Test Pack 10 Ml (Should Be Ce/Iso13485 Cetfied Company) , Liquicelin E 3Ml (Tulip) , Liquid Paraffin (Heavy Grade) (Refractive Index Of 1.48. It Should Be Colourless, Odurless, Transparent, Free From Fluorescene In Day Light With Relative Density Of 0.827 To 0.890, Viscosity Of 110 To 230 M Pa S., Specific Gravity Of 0.76-0.78 At 15.5°C) , Liquid Parraffin Heavy 500Ml (Qualigen/Rankem/Nice) , Liquiplastin 5Ml (Tulip) , Litmus Paper Blue & Red 100 Strips Per Pack , L-Mold , Loop Holder (Stainless Steel Rod With Heat Resistant Handle Holder; 6In Length; With Screw Arrangement To Hold Firmly 24 Swg Nichrome Wire Inoculation Loop) , Lugols Iodine 100 Ml (Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved.) , Lyse 500Ml (Should Be Ivd/Ce/Iso13485 Certifiedco) , Macconkey Agar W/O Cv,Nacl,W/0.5 500Gm (Should Be Ivd/Ce/Iso13485 Certified Co) , Macconkey Broth (Macconkey Broth Jn Form - Medium Granules (Dehydrated (Dcm)), Packaging - Pkg Of 500 G, Storage Condition (Tightly Closed. Dry), Technique(S) Microbiological Culture: Suitable, Color - Gray, Ph 7.1-7.5 (25 °C, 35 G/L In H2o, After Autoclaving), Solubility 35 G/L, Bulk Density 640 Kg/M3, Storage Temp.15-25°C Suitability Escherichia Coli Salmonella Spp. Enterobacteriaceae) , Macconkey Broth Purple Ds 500Gm Should Be Ivd/Ce/Iso13485 Certified Construction Of , Macconkey Broth Purple Ss 500Gm Should Be Ivd/Ce/Iso13485 Certified Construction Of , Macconky Agar 500 Gmisolation And Differentiation Of E.Coli And Other Enteric Bacteria -Clinical Samples - Pathological Material -Colour And Clarity Of Prepared Medium Should Be Red With Purplish Tinge Coloured Clear To Slightly Opalescent Gel Forms In Petri Plates -Ph Should Be 6.90-7.30 -Store Between 10- 30°C -Should Be Ce And Ivd Certified. 500Grm Packing , Magnesium Kit 2X50ml Should Be Ce/Iso13485 Cetfied Company , Malaria Pf/Pv Or Pf/Pan Card Tulip/Jmitra/Arkray/Meril , Mannitol 500 Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Matrix Ahg Coombs Test Gel Card Pack(1X6x24card Kit) Should Be Ivd/Ce/Iso13485 Certified , Matrix Diluent 2 Liss 250Ml Should Be Ivd/Ce/Iso13485 Certified , Matrix Forward & Reverse Grouping Gel Card (1X24 Card Kit) Should Be Ivd/Ce/Iso13485 Certified , Matrix Liquipap 5Ml Should Be Ivd/Ce/Iso13485 Certified , Matrix Octoplus Complete Grouping Gel Card ( 1X24 Card Kit) Should Be Ivd/Ce/Iso13485 Certified , Matrix Rh Phenotype Gel Card , Mcfarland Standard Reader 0.5 Digital Should Be Ivd/Ce/Iso13485 Certified , Mct Rnase/Dnase Free 2Ml Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Measels Elisa Kit (Igm) 1*96Type Of Sample For Test Should Be Serum/Plasma With Controls, Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Measuring Cylinder (Glass) Borosilicate 100Ml , Measuring Cylinder (Glass) Borosilicate 500Ml , Measuring Scoop 100Ml Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Meat Extract (High Media) Should Be Ivd/Ce/Iso13485 Certified , Meropenem Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Methanol Acetone Free 500 Ml Qualigen/Rankem/Nice , Methanol Pack Of 2.5 Ltr Qualigen/Rankem/Nice , Methyl Red (500Gm) Should Be Ivd/Ce/Iso13485 Certified Construction Of , Methylated Spiritchemical Name: Ethanol Denatured + 5% Lsopropyl Alcohol + 5% Methanol, Molecular Structure:C2h5oh, Molecular Wt: 46.07, Purity: 99%All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Methylene Bluechemical Name: Methylthionine Chloride, Chemical Structure: C16h18cln3s, Molecular Wt:319.9, Dye Content: Approx.82% (Should Be Available On The Container.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Methylene Blue 125Ml Qualigen/Rankem/Nice , Methylene Blue 25Gram Powder Qualigen/Rankem/Nice , Micro Protien 1X50ml Erba Transasia , Micro Tips Largernase/Dnase Free Pack Of 500 Tarson/Genaxy/Abdos , Micro Tips Small Rnase/Dnase Free Pack Of 1000 Tarson/Genaxy/Abdos , Micro Tips Stand 1000-5000 Ul Tips Whogmp/Fda/Iso13485/Ce Certified Construction Of , Micro Tips Stand 100-1000 Ul Tips Whogmp/Fda/Iso13485/Ce Certified Construction Of , Micro Tips Stand 10-200 Ul Tips Whogmp/Fda/Iso13485/Ce Certified Construction Of , Microbial Identification Enzyme Substrate Reactionbased Kit Mannual Should Be Ivd/Ce/Iso13485 Certified , Microprotien 50 Mlerba , Microscope Bulb (Halogen Lamp) 1*10 , Microtips 0.1 - 10 Ul 1000Pc Rnase/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips 0-10 Micro Litre Rnase/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips 0-20Ul Rnase/Dnase Free/Pyrogen Should Be Ivd/Ce/Iso13485 Certified , Microtips 100-1000Ul Rnase/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips 1-5 Ml Rnase/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips 2-200Ul Rnase Free/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips 50-300Ul Rnase/Dnase Free Should Be Ivd/Ce/Iso13485 Certified , Microtips Filtered 0- 10Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 96Pcs X10 Racks Per Box 1000Ul , Microtips Filtered 0- 200 Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 96Pcs X10 Racks Per Box 1000Ul , Microtips Filtered 0- 20Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 96Pcs X10 Racks Per Box 1000Ul , Microtips Filtered 1Ml - 5 Mlivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 96Pcs X10 Racks Per Box , Microtips Filtered 50-300 Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 96Pcs X10 Racks Per Box , Microtome Knife (Thermo Scientific Mb35 Premier) , Moily Test Medium 500 Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Montoux Ppd Vial 5Tu/10Tu 5Ml Arkray/Beacon , Morter Pastelsheavy Glass, External Diam. 4, Capacity 8 Oz , Motility Test Medium 500 Gm Should Be Ivd/Ce/Iso13485 Certified , Moxifloxacin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Mr Reagent 125 Ml Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Mueller Hinton Agar 500Gm Should Be Ce/Iso13485 Cetfied Company , Mui Agar 500Gm Should Be Ivd/Ce/Iso13485 Certified , Muller Hinton Agar 500 Mg Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Multipurpose Labelling Tape 75X500 Should Be Ce/Iso13485 Certified , Multistick 10 Parameter Erba , Multistix 10 Parameter For Urine Analyser Siemens 1X100 Siemens , Mumps Elisa Kit 1*96Type Of Sample For Test Should Be Serum/Plasma With Controls Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , N Acetyl Cysteinechemical Structure:C5h9no3s, Mol Wt: 163.2 2.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , N/10 Hcl 500 Ml Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , N95 Mask Ffp2 Niosh Certified Without Respirator , Nalidixic Acid Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Nalidixic Acid Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Needle Holder , Needle Hub Cutter 1 Ltr Plastic Should Be Iso9001-2015 Certified , Needle Hub Cutter S.Steel With Detachable Sharp Contaier 5Ltr Should Be Iso9001-2015 Certified , Needle Hub Cutter S.Steel With Detachable Sharpcontaier 800Ml Should Be Iso9001-2015 Certified , Netilmicin Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Netilmicin Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Neubaur Chamber Silver Line , New Methlene Blue 500 Ml Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , New Methylene Blue 125Ml , Nitrile Gloves Small/Medium/Large 1X100 , Nitrofurantoin Antibiotic Disc (6 Mm) 300 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Nitrofurantoin Antibiotic Disc (6 Mm) 300 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Norfloxacin Antibiotic Disc (6 Mm) 2 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Norfloxacin Antibiotic Disc (6 Mm) 2 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Novobiocin Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Novobiocin Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 50 To 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Ns 1 Dengue Elisa Kit 1*96 Generation Of Test Should Be Early Elisa It Should Be Elisa Assay Format Assay Time Should Be Of 90 To 120 Mins It Should Have Ready To Use Conjugate System Type Of Sample For Test Should Be Serum/Plasma Sensitivity 99% Specificity 99% Storage Temperature 2-8C Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved , Nuclear Grade Water( Rna Ase,Dna Ase Free)Should Be Ivd/Ce/Iso13485 Certified , Nueubaur Chamber Marienfield , Nutrient Agar 500 Gmclinical Samples - Pathological Material, Food And Dairy Samples; Water Samples. -Colour And Clarity Of Prepared Medium Should Be Light Yellow Coloured Clear To Slightly Opalescent Gel Forms In Petri Plates -Ph Should Be 7.20-7.60 -Should Be Ce And Ivd Certified. -Storage Temperature10-30°C -It Can Be Enriched With Blood Or Other Biological Fluids -For Cultivation Of Less Fastidious Microorganisms -500Grm Packing , Onidine Strips Should Be Ivd/Ce/Iso13485 Certified , Optochin Antibiotic Disc (6 Mm) Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Optochin Antibiotic Disc (6 Mm) Vial Contain 50 To 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Ot Gown (Reuseable ) , O-Toludine Reagent Iupac Name 3-Amino-7-(Dimethylamino)-2-Methyl-5?4-Phenothiazin-5-Ylium Chloride, Molecular Weight (G/Mol) 305.82, Formula Weight 305.82G/Mol Packaging Glass Bottle, Ph 1.8 To 2, Quantity 500 Ml , Oxacillin Antibiotic Disc (6 Mm) 1 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Oxacillin Antibiotic Disc (6 Mm) 1 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Oxidase Discsoxidase Discs Are Sterile Filter Paper Discs Impregnated With N, N-Dimethyl-P-Phenylenediamine Oxalate, Ascorbic Acid And A-Naphthol. These Discs Overcome The Neccessity Of Daily Preparation Of Fresh Reagent. Pseudomonas Aeruginosa Atcc 27853 Positive : Deep Purplish Blue Colouration Of Disc ; Staphylococcus Aureus Atcc 25923 Negative : No Colour Change. , Pap Smear Kit 4Pc Should Be Ivd/Ce/Iso13485 Certified , Pap Stain 250Smears Should Be Ivd/Ce/Iso13485 Certified , Papnicolaus Solution Ea-36 125Ml Nice/Rankam/Qualigens , Papnicolaus Solution Og-6 125Ml Nice/Rankam/Qualigens , Para Filmsize 4 In X 125 Ft Roll , Paraffin Liquid Heavy 500 Ml Nice/Rankam/Qualigens , Paraffin Wax 500 Gm Should Be Ivd/Ce/Iso13485 Certified , Paraffin Wax With Ceresin 500 Gm Nice/Rankam/Qualigens , Parafilm M 2X250 Should Be Ivd/Ce/Iso13485 Certified , Parafilm Oil Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Pasteur Pipette 1 Ml Should Be Ce/Iso13485 Certified , Pasteur Pipette 1 X12 Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Pasteur Pipette 3 Ml Tarson/Genaxy/Abdos , Pediatric Vein Findershould Be Portable, Battery Operated Should Be Usfda Certified And Beneficial In Neonatal And Pre-Term Cases For Locating The Tiny Veins. Light Source Should Be Led. , Penicillin Antibiotic Disc (6 Mm) (10 Units), Vial Contain 100 Discfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Peptone Water Recommended By Bis For Detection Of Indole Production By Escherichia Coli . Peptone Water With Ph Adjusted To 8.4 Is Suitable For The Cultivation And Enrichment Of Vibrio Species. , Peptone Water 500 Gmclinical Samples - Pathological Material, Food And Dairy Samples; Water Samples. -Colour And Clarity Of Prepared Medium Should Be Light Yellow Coloured Clear To Slightly Opalescent Gel Forms In Petri Plates -Ph Should Be 7.20-7.60 -Should Be Ce And Ivd Certified. -Storage Temperature10-30°C -It Can Be Enriched With Blood Or Other Biological Fluids -For Cultivation Of Less Fastidious Microorganisms -500Grm Packing , Permanent Marker (Pen)Black , Ph Meterph Range 0-14 With Digital Display And Stand By And Calibration Mode; Hand Held , Pocket-Size With 1.4V Button Cells Give 350Hrs Continuous Operation;Size 148X28x15mm, 85G (Approx.).Resolution: 0.01,Mv Range: ± 1999,Accuracy: ± 0.01,No. Of Digits: Three.Voltage Regulator Of Appropriate Rating To Beincluded For Each Incubator To Cope With 160-260 V , Ph Meter Digital Ionex , Ph Meter Digital Hanna , Ph Paper Strips 1*1 , Phenol 500Gm Qualigen/Rankem/Nice , Phenol Solution 5% 500Ml Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Phosphorus Kit 2X50 Ml Erba Should Be Ce/Iso13485 Cetfied Company , Piperacillin + Tazobactum Antibiotic Disc (6 Mm) 100 Mcg, + 10 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Piperacillin + Tazobactum Antibiotic Disc (6 Mm) 100 Mcg, + 10 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Piperacillin Antibiotic Disc (6 Mm) (100 Mcg), Vial Contain 100 Discfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Pipette Filter Tips (Sterile) 1000Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 1000 Pcs Per Pack , Pipette Filter Tips (Sterile) 10Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 1000 Pcs Per Pack , Pipette Filter Tips (Sterile) 200Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 1000 Pcs Per Pack , Pipette Filter Tips (Sterile) 20Ulivd Certified Low Retention Racked Filter Tips. Rnase Free Dnase Free Pyrogen Free 100% Hydrophic Filter Pure Porous Pe Filter Free From Chemical Additives, 99.9% Bacterial Aerosol Filtration Efficiency. Sterile 1000 Pcs Per Pack , Pipette Fixed Volume Thermofisher /Himedia , Pipette Fixed Volume Autoclavable Thermofisher/Himedia , Pipette Stand 5 Placesholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Pipette Variable Volume Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Pipette Variable Volume Autoclavable Thermofisher/Himedia , Plastic Tray Whogmp/Fda/Iso13485/Ce Certified Construction Of , Pm Kit For Chem 5X Erbatransasia , Pneumatic Trough Should Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Potassium Dichromate Powderchemicals Formula:K2cr207, Formula Wt:294.2, Minimum Assay:99.5% All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Potassium Fericinide 500Gm Should Be Ce/Iso13485 Cetfied Company , Potassium Hydroxide (Koh) Pellets/Flakes 500 Gm Should Be Ivd/Ce/Iso13485 Certified , Potassium Hydroxide (Koh) Powder 500 Gm Should Be Ivd/Ce/Iso13485 Certified , Potassium Hydroxide (Koh) Sol. 40% 500Ml Should Be Ivd/Ce/Iso13485 Certified , Potassium Monosulpride 500Gm Should Be Ce/Iso13485 Cetfied Company , Potassium Nitrate Reagent. 500Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Potassium Permaganate Kmno4, Formula Wt:158 ,500Gm. All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Ppe Kit Washable Should Be Ce/Iso13485 Cetfied Company , Preheparinised Abg Syringes Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Probe Cleaner 4 X 50 Ml Should Be Ce/Iso13485 Cetfied Company , Probe Cleaner For 3 Part 100 Ml Should Be Ce/Iso13485 Cetfied Company , Probe Cleaner For 5 Part Cell Coumter Bc 6800 Should Be Ce/Iso13485 Cetfied Company , Psa Elisa 1X96 Test Should Be Ivd/Ce/Iso13485 Certified , Psa Kit Elisa 1 X 96 Test Per Kittype Of Sample For Test Should Be Serum/Plasma Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Ra Factor 35 Test Kit Tulip/Arkray , Ra Factor Rapid Card Should Be Ivd/Ce/Iso13485 Certified , Rapid Antigen Test For Bacterial Meningitis Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Rapid Test Kits, Typhi 1*25 Cardsrapid Qualitative Test For Differential Detection Of Salmonella Typhi (S.Typhi) Igm And Igg Antibodies In Human Serum / Plasma. Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Ready Made Blood Agar Plates Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Reagent Bottle Wide Mouth 125Ml Should Be Ce/Iso13485 Cetfied Company , Reagent Diluent 20Ltr Pack For Cbc 3Part Ad3200/Pe6000 Should Be Ce/Iso13485 Cetfied Company , Reagent Rinse Cleaner 10Ltr Pack For Cbc 3Part Ad3200/Pe6000 Should Be Ce/Iso13485 Cetfied Company , Red Spot-Pe Card Tulip , Reticulocyte Sol 125Ml Nice/Rankam/Qualigens , Rh View Box , Rnase And Dnase Degradation Solutionsform:Liquid Completely Degrades Contaminating Dna And Rna At The Level Of Pcr Sensitivity Ideal For Cleaning Pcr Tubes, Pcr Machine Surfaces, Pipettors, Lab Benches, Lab Equipment. 250Ml Per Bottle , Rnase And Dnase Degradation Solutions Wipesform:Wipes/Towels Completely Degrades Contaminating Dna And Rna At The Level Of Pcr Sensitivity Ideal For Cleaning Pcr Tubes, Pcr Machine Surfaces, Pipettors, Lab Benches, Lab Equipment. 100 Wipes Per Packs , Rpr Card Test Should Be Ce/Iso13485 Cetfied Company , Rt Pcr Plate 1X96well Hsp9655 Sholud Be Whogmp/Fda/Iso13485/Ce , Rt Pcr Plate Optical Sealer 1X96well Msb1001 Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Rt Pcr Strip Cap Flat 8Cap 0.2Ml 120 Pc Optical Tcs0803 Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Rt Pcr Tube Strip-8 Lo Profile 120Pc T1s0801 Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Rubella Igg Elisa 96 Test Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , S.Troponin 1(Manual) Should Be Dcgi Approved/European Ce Marked /Ivd Approved. , Safety Lancet Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Salmonella Shigella Agar Vegetable Peptone Based Medium (500 Gms) Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Sars Cov2 One Step Rtpcr Kit 96 Test Icmr Approved , Sars Cov2 Rtpcr Kit 96 Test Icmr Approved , Scrub Typhus Antigen-Antibody Elisa Test Kit Qualitative Detection Of Scrub Typhus Igm Antibodies In Human Serum/Plasma Sensitivity: 100% Specificity: 100% Longer Shelf Life: 24 Months At 2-8°C Approved By Drug Controller General Of India (Dcgi) ,Ivd Assay Procedure Should Not More Than 120 Mins Break-Away Micro Well Strips Ready To Use Enzyme Conjugate Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Scrub Typhus Rapid Card Test Should Be Rapid 3 Band Test Should Detect Igg/Igm Antigen It Should Be Lateral Flow Through Assay Format It Should Have Ready To Use Conjugate System Assay Time Should Be Of 15 Mins Type Of Sample For Test Should Be Serum/Plasma/Whole Blood 10Ul Of Sample Is Required For The Test Sensitivity Should Be 100% Storage Temperature 2- 40 C Specificity 100% Ivd Approved Validity:24 Months Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Serum Albumin Kit Of 100 Ml Meril/Beacon/Agd , Serum Albumin Kit Of 5X50ml Erbatransasia , Serum Cholestrol Kit 100 Ml 4X25 Meril/Beacon/Agd , Serum Creatinine Kit 250 Ml Meril/Beacon/Agd , Serum Creatinine Kit Liquid Stable 4X60ml Erbatransasia , Serum Ferritin Elisa Kit , Serum Hdl Kit 2X50ml Erbatransasia , Serum Ldl Kit 100 Mlshould Be Ce/Iso13485 Cetfied Company , Serum Ldl Kit 4X30 Ml Erbatransasia , Serum P.T.I./ Inr Kitshould Be Ce/Iso13485 Cetfied Company , Serum Psa Elisa Kit , Serum Sgot Kit 100Ml Kit 2X50 Meril/Beacon/Agd , Serum Sgot Powder 5 X 20Ml Erbatransasia , Serum Sgpt Kit 100Ml Kit 2X50 Meril/Beacon/Agd , Serum Sgpt Kit Powder 5X20 Ml Erbatransasia , Serum Triglyceride Kit 4X25ml Meril/Beacon/Agd , Serum Triglycrides Kit Powder 5X20ml Erbatransasia , Serum Uric Acid Kit 4X10ml Meril/Beacon/Agd , Serum Uric Acid Kit Powder 5X20 Ml Kit Erbatransasia , Sharp Container 10 Liter Blue/White , Sharp Container 800Ml Blue/White , Sharp Container Blue 5Ltr Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Sharp Container White 5Ltr Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Shigella Antisera (Mono Valent For All 4 Species) 2 Mlivd Approved/Ce Certified , Simmons Citrate Medium 500 Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Single Channel Variable Volume Micropipette 1000 Ulmanually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Single Channel Variable Volume Micropipette 20-200 Ulmanually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Single Channel Variable Volume Micropipette 0.5-10 Ulmanually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Single Channel Variable Volume Micropipette 10-100 Ulmanually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Single Channel Variable Volume Micropipette 2-20 Ulmanually Operated Pipetting Type -Air Cushion Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Single Channel Variable Volume Micropipette 5-50 Ulmanually Operated Pipetting Type -Air Cushion -Ultra Light Weight Spring Loaded Tip Cone For Minimal Tip Attachment Forces. Soft Eject Low Tip Ejection Force Fully Autoclavable Large 4 Digit Volume Display Should Include Calibration Certificate From Manufacture , Slide Boxfor Storing 100 Slides, Plastic Storage Boxes, Approximate Dimensions: 8.75 (22.2 Cm) X 6.75(17.15 Cm) X 1.3(3.3Cm ) Cm , Slide Cabinit Almirah 10000 Quantity , Slide Mailor , Slide Stand Wooden , Slide Storage Box 50 Slide , Slide Tray (For 20 Slides) , Slide Tray Aluminium , Sodium Chloride (Nacl 58.44) 500 Ml , Sodium Citratechemical Name: Trisodium Citrate Dihydrate, Annual Repair Gradechemical Structure:Na3c6h5o7.2H,O,Molecular Wt (Fw):294.10, Purity: 99%.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Sodium Citrate 3.8% Solution 500Ml Qualigen/Rankem/Nice , Sodium Dihydrogen Orthophosphate (Mono Sodium Phosphate) , Sodium Hypochloride 5Ltr. Qualigen/Rankem/Nice , Sodium Hypochlorite 1 X 5Ltr Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Sodium Potassium Meta Bisulphate Powder 500 Gm , Soyabean Casein Digest Medium 1*10Ml Ivd Approved/Ce Certified , Sparfloxacin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Spirit Lamp 1*1Steel , Spot Bandagemedicated Pads With Nitrofurazone I.P. Should Be Made Up Of Breathable Fabric And Waterproof Should Have Unique Strong Hypoallergenic Adhesive Formula Should Not Leave Back Any Stains Or Residual Stickiness After Use. Size 22Mm To 25Mm , Sputum Cups /Serile Containers/Universal Containerscups Made Of Special Medical Grade Polypropylene, Thin Plastic, Translucent, Diameter - 4Cm,Capacity-30Ml,Screwable Cap Should Also Be Made Of Special Medical Grade Polypropylene And Should Be Air Tight, Leak Proof.Certification-Ce/Iso. , Staining Rackshould Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Steel Cassets , Steel Container 1000 Gm , Steel Container 500 Gm , Steel Tray Square , Sterile Disposable Petri Plates Optically Clear (100 Mm Dia )Material: Polystyrene Size:100Mm Gamma Or Eto Sterilized,Ivd Approved Individually Packed Extremely High Optical Clarity For Easy View On Microscope , Sterile Disposable Petri Plates Optically Clear (110 Mm Dia )Material: Polystyrene Size:110Mm Gamma Or Eto Sterilized,Ivd Approved Individually Packed Extremely High Optical Clarity For Easy View On Microscope , Sterile Disposable Petri Plates Optically Clear (90 Mm Dia X 15 Mm)Material: Polystyrene Size:90Mmx15mm Gamma Or Eto Sterilized Ivd Approved Individually Packed Extremely High Optical Clarity For Easy View On Microscope , Sterile Urine Container Capacity:35-40Ml Diameter: 40Mm Length:45Mm Material: Polypropylene Screw Cap Graduated Leak Proof Sterile , Sterile Urine Container (1X100)Capacity:10Ml Diameter: 40Mm Length:45Mm Material: Polypropylene Crew Cap Graduated Leak Proof, Sterile , Stop Watchmechanical Stop Watch, For A Maximum Of 60 Minutes Duration With Timer And Alarm, Dial Diameter :10 Cms,Thickness: 5 Cm.Accuracy: 1/5 Sec.Equipment Quoted Should Comply With Indian Standards Institutions Guidelines. , Stop Watch 1*1 With Hours & Min & Sec , Storage Vial 2Ml Tarson 4.50Ml Should Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Stromatolyser 500Ml Sysmex , Sucrose 500 Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Sulfuric Acid Conc.(100%) 500 Ml Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Sulphur Powder 500 Gm. Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Sulphuric Acidh2so4, Molecular Wt. 98.08, Minimum Assay: 98%, Colour: Clear.All Chemicals Should Have The Hazard Communication Standard From Chemical Manufacturers And Material Safety Data Sheets (Msds) For Each Chemical Item Should Be Provided To The Purchaser Of The Product At The Time Of The Order And Thereafter, Anytime The Msds Is Significantly Revised. Also, All The Chemicals Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Sulphuric Acid 2.5 Ltr. Qualigen/Rankem/Nice , Sulphuric Acid 500Ml Qualigen/Rankem/Nice , Surgical Blade 22 , Susceptibility Antimicrobial Testing Semi Autoanalyser Ast Should Be Ce/Iso13485 Cetfied Company , Swab Alcohol Disposable Should Be Ce/Iso13485 Certified , Swab Stick Sterile Should Be Ivd/Ce/Iso13485 Certified , Swab Stick Sterile With Tube Should Be Ce/Iso13485 Certified , Syphilis Elisa Test Kit Sensitivity: 100% Specificity: 100% Longer Shelf Life: 24 Months At 2-8°C Approved By Drug Controller General Of India (Dcgi) ,Ivd For The Usage In Blood Banks Assay Procedure Should Not More Than 120 Mins. Break-Away Micro Well Strips Ready To Use Enzyme Conjugate Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Syphilis Tpha Vdrl Card Each Tulip/Jmitra/Arkray/Meril , Syringe Abg , Sysmex Cell Counter Controls Sysmex , T3 Elisa Kit 1X96 Testshould Be Ce/Iso13485 Certified , T4 Elisa Kit 1X96 Testshould Be Ce/Iso13485 Certified , Tcbs Agar 500 Gmtcbs Agar Is Used For Selective Isolation Of Vibrio Cholerae And Other Enteropathogenic Vibrios As Recommended By Bis Under The Specifications Is:5887(Part V)-1976. This Formulation Is Recommended By Bis For Isolation Of Vibrio Cholerae And Vibrio Parahaemolyticus. It Promotes Rapid Growth Of Pathogenic Vibrio S After 24 Hours Incubation At 37°C. The Contaminating Non- Vibrio S Are Suppressed. Strains Of Vibrio Cholerae Produce Yellow Colonies On Tcbs Agar Because Of Fermentation Of Sucrose. Vibrio Alginolyticus Also Produce Yellow Colonies. Vibrio Parahaemolyticus Is A Sucrose Non-Fermenting Organism And Produces Blue-Green Colonies, As Of Vibrio Vulnificus. Agar Should Have Their Detailed Specifications,Potency, Date Of Manufacture, Date Of Expiry, Precautions For Use Mentioned On The Conatiners. , Teicoplanin Antibiotic Disc (6 Mm) (30 Mcg), Vial Contain 100 Discfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Test Tube 12X100 Without Rim (Borosilicate Glass) , Test Tube 12X75 Without Rim (Borosilicate Glass) , Test Tube 15X125 Without Rim (Borosilicate Glass) , Test Tube 18X150 Without Rim (Borosilicate Glass) , Test Tube Basket Bigsholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Test Tube Basket Peg Racksholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Test Tube Peg Racksholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Test Tube Plastic 12X100 Tarson/Genaxy/Abdos , Test Tube Plastic 12X75 Tarson/Genaxy/Abdos , Test Tube Rack 40 Hole Plastic Tarson/Genaxy/Abdos , Test Tube Stand 90 Hole Plastic Tarson/Genaxy/Abdos , Tetracycline Antibiotic Disc (6 Mm) 30Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Tetramethyl Paraphenyl Diamine Di Hydro Chloride 25 Gm Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Thermal Paper 50Mm X 15Mtr55gsm Top/Marc , Thermal Paper 50Mm X 20 Mtr55gsm Top/Marc , Thermal Paper 52Mm X 20Mtr55gsm Top/Marc , Thermal Paper 57Mm X 20Mtr55gsm Top/Marc , Thermal Paper 80Mm X 20 Mtr55gsm Top/Marc , Thermal Paper For Bio Analyzer 1 X1should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Thermal Paper Imported 110Mm55gsm Top/Marc , Thermal Paper Imported 50Mmx25mtr55gsm Top/Marc , Thermal Paper Imported 57Mmx25mtr55gsm Top/Marc , Thermocol Box (Medium) , Thermocol Box (Small) , Thymol Crystal , Ticarcillin-Clavulanic Acid Antibiotic Disc (6 Mm) (75/10 ?Cg) Vial Contain 100 Discfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Tigecycline Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Tissue Paper Roll 240 Pulls 10Nx10n Big Double Ply , Tobramycin Antibiotic Disc (6 Mm) ,10 Units Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm, Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Toluidine Stain Blue , Torch Igm,Igg Elisa 96 Test Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Total Ige Elisa 96 Test Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Total Protein Kit 4X50 Ml Meril/Beacon/Seimens , Total Protein Kit 5 X 50Ml Erbatransasia , Touniquit With Adhesive Holder Largetynor , Touniquit With Adhesive Holder Medium , Tourniquet Clutch , Tpha Strips Immunochromatographic Single Should Be Usfda Approved/European Ce Marked /Ivd Approved. , Transparent Tapesize 1 Inch 65 M , Triglycerides Kit 100 Ml Meril/Beacon/Agd , Triglycerides Kit Powder 5X20 Ml Erbatransasia , Triple Sugar Iron Agar 500G Sholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Triple Sugar Iron Agar Vegetable Peptone Based Medium (500 Gms) Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Troponin I Card Should Be Ce/Iso13485 Cetfied Company , Troponin T Card Should Be Ce/Iso13485 Cetfied Company , Tsh Elisa Kit 1X96 Test Should Be Ce/Iso13485 Certified , Ttg Kit 1*96 Testtype Of Sample For Test Should Be Serum/Plasma , Tube Rack Aluminium 1*1 , Typhoid Card Each Igg/Igm Should Be Ce/Iso13485 Cetfied Company , Uniplastin 5Ml Should Be Ce/Iso13485 Cetfied Company , Upt Cards(Pregnancy Cards) Each Tulip/Meril/Agd , Uric Acid Powder 5X20 Ml Test Kit Erbatransasia , Uric Acid Test Kit 100 Ml Meril/Beacon/Agd , Urine Strips Albumin, Sugar Should Be Ce/Iso13485 Cetfied Company , Urine Strips Ketone Bodies Siemens , Urine/Sputum Container 30Ml Sterile Single With Coa Certificatelevram/Polylab/Tarson , Urine/Sputum Container 50Ml Sterile Single With Coa Certificatelevram/Polylab/Tarson , Uristix Siemens Albumin, Sugarsiemens , Vaccutainer Red Top Each Jk/Lev/Hemo , Vaccutainer Red Top 5 Ml 13X 100 Mm Each Jk/Lev/Hemo , Vaccutainer Red Top Neonate Each 1X100 Each Jk/Lev/Hemo , Vaccutainer K3 Edta Neonate Each Jk/Lev/Hemo , Vaccutainer K3 Edta Each Jk/Lev/Hemo , Vaccutainer Lithium Heparin 4Ml Each Jk/Lev/Hemo , Vaccutainer Lithium Heparin 5Ml 13 X 100 Mm Each Jk/Lev/Hemo , Vaccutainer Needle Each 21/22/23 No. Jk/Lev/Hemo , Vaccutainer Sodium Fluoride Each Jk/Lev/Hemo , Vaccutainer Sodium/Lithium Heparin 5Ml Each Jk/Lev/Hemo , Vacutainer Black Top Sodium Citrate 3.8% Each Jk/Lev/Hemo , Vacutainer Blood Collection Flashback Needle 21Gshould Have Transparent Plastic/Glass Hub Sterile Compatible To Entire Vacutainer Range Of Blood Collection Devices And Accessories. Iso : 13485-2016 , Vacutainer Blood Collection Flashback Needle 22Gshould Have Transparent Plastic/Glass Hub Sterile Compatible To Entire Vacutainer Range Of Blood Collection Devices And Accessories. Iso : 13485-2016 , Vacutainer Blue Top Sodium Citrate 3.2% Jk/Lev/Hemo , Vacutainer Needle Holdersholud Be Whogmp/Fda/Iso13485/Ce Certified Construction Of , Vacutainer Yellow Top Serum Separator Gel Tube Eachjk/Lev/Hemo , Vancomycin Antibiotic Disc (6 Mm) 30 Mcg, Pack Has 5 Cartridges Of 50 Discs With Plastic Disc Dispensorfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Vancomycin Antibiotic Disc (6 Mm) 30 Mcg, Vial Contain 100 Discfilter Paper Disc Of Size 6Mm,Impregnated With Required Potency Of Antibiotic. Should Be Iso9001/Iso 13485 Certified And Fda/Ce Approved. , Vdrl Strip 1*100Should Be Usfda Approved/Euand Ce Marked /Ivd Approved. , Vibrio Cholerae Inaba (Mono Valent) 2 Mlivd Approved/Ce Certified , Vibrio Cholerae Ogawa (Mono Valent) 2 Mlivd Approved/Ce Certified , Vibrio Cholerae Poly 01 (2 Ml)Ivd Approved/Ce Certified , Wash 4X50ml Should Be Ce/Iso13485 Certified , Water Bathstainless Steel, Insulated Double Walled, Inner Wall Of Stainless Steel, Thermostatic Temp. Control From Ambient To 85 - 900 C (?0.50 ) Complete With Immersion Heater, Aluminium/Ss Cover, Brass Drain Ambient To 85 - 900 C (?0.50 ) Complete With Cock, 220-240 Volts Ac, 50Hz., Dimensions(Approx.)27X30x15 Cms; Power : (Approx.)480W; Digital Microprocessor Display To(Approx.)480W; Digital Microprocessor Display To Seamless Reservoir With No Welds To Leak Or Rust, See-Through Cover Is Hinged And Removable , And Steeply Gabled To Accept Taller Samples. Iec-1010 Approved.Equipment Quoted Should Comply With Indian Standards Institutions Guidelines Or Any Other National Or International Guidelines. , Water Bath Dry Should Be Ce/Iso13485 Certified , Weil Felex Elisa Kit 1*96 Should Be Usfda/Dcgi Approved/European Ce Marked /Ivd Approved. , Whattman Filter Paperfilter Paper No. 1,Pore Size-11Um, Diameter:- 12.5 Cms For Filtering Carbol Fuchsin Using A Small Funnel Of 10Cm Maximum Diameter, Smooth On One Side And Rough On The Otherside, Water Permeable,Medium Flow Filter Paper , Widal 4X5 Ml Tulip/Arkray/Beacon , Xylene 2.5 Litre Qualigen/Rankem/Nice , Xylene 500Ml Qualigen/Rankem/Nice , Xylose Lysine Decarboxylase Agar Vegetable Peptone Based Medium (500 Gms)Should Be Usfda/Icmr Approved/European Ce Marked /Ivd Approved. , Zip Lock Pouch (4X10)Size (4X10) Inch Transparent 100Pcs Per Pack
Contract Date: Mar 05, 2026 Contract Value : 75.00 Lakh
Government Departments No of Bidders 4
34.
Educational and Research Institute #9392647 Technical Bid
Supply Of Printed Books As Per Tender Document , Supply Of Printed Books , Heat Transfer/Binay K. Dutta/Phi Learning Private Limited/978-81-203-1625-6 , Stoichiometry And Process Calculations/K.V.Narayanan And B.Lakshmikutty/Phi Learning Private Limited/978-8120352896 , Elements Of Chemical Reaction Engineering/H. Scott Fogler/Phi Learning Private Limited/978-7502741006 , Chemical Reaction Engineering/Octave Levenspiel/Wiley/978-8126510009 , Mass Transfer Operations/Robert Treybal/Mcgraw Hill Education/N/A , Transport Processes And Separation Process Principles/Chistie John Geankoplis/Pearson Education India/N/A , Principles Of Mass Transfer And Separation Processes/Binay K. Dutta/Phi Learning Private Limited/N/A , Chemical Process Safety: Fundamentals With Applications /Daniel Crowl , Joseph Louvar/Pearson Education India/N/A , Transport Phenomena/R. Byron Bird, Warren E. Stewart, Edwin N. Lightfoot/Wiley/N/A , Chemical Process Control: An Introduction To Theory And Practice/George Stephanopoulos/Pearson/N/A , Process Systems Analysis And Control/Steven E Leblanc Donald R. Coughanowr/Mcgraw Hill Education/N/A , Chemical Engineering Design: Principles, Practice And Economics Of Plant And Process Design/Gavin Towler, Ray Sinnott/Butterworth-Heinemann Ltd/N/A , Plant Design And Economics For Chemical Engineers/Max Peters, Klaus Timmerhaus, Ronald West, Max Peters/Mcgraw Hill/N/A , Unit Operations Of Chemical Engineering/Warren Mccabe/Mcgraw Hill Education/N/A , Process Plant Simulation/B.V Babu/Oxford University Press/N/A , A Textbook Of Machine Design/R.S.Khurmi/S Chand/N/A , Mechanical Operations Fundamental Principles And Applications/Dr. Kiran D. Patil/Nirali Prakashan/N/A , Unit Operation -1/K. A. Gavhane/Nirali Prakashan/N/A , A Textbook Of Heat And Mass Transfer/Rk Rajput/S Chand/N/A , Numerical Methods For Engineers/Steven Chapra Raymond Canale/Mcgraw Hill Education/N/A , A Text Book Of Railway Engineering/Saxena S.C /Dhanpat Rai Publication/N/A , Adsorption Analysis: Equilibria And Kinetics (With Cd Containing Computer Matlab Programs): 2 (Series On Chemical Engineering)/ Duong D Do/Imperial College Press/978-1860941375 , Advanced Concrete Technology/Zongjin Li/John Wiley & Sons Ltd/978-0470437438 , Advanced Mechanics Of Solids/Srinath, L.S./Tata Mcgraw-Hill/978-0070139886 , Advanced Reinforced Concrete Design/Krishnaraju N/Cbs Publishers/978-8123929606 , Alkali-Aggregate Reaction And Structural Damage To Concrete /Geoffrey E Blight/Crc Press/978-1138073036 , An Introduction To The Finite Element Method/Reddy, J.N./Mcgraw Hill/978-9390385270 , Basic Structural Analysis/Reddy, C. S./Tata Mcgraw Hill/978-0070702769 , Classical And Computational Solid Mechanics/Fung,Tong And Chen/World Scientific Publishing Co Pte Ltd/978-0000988508 , Concrete Structures/Bhattacharjee J/Cbs Publishers/978-9385915901 , Concrete Structures Subjected To Impact And Blast Loadings And Their Combinations/Zhang Chunwei/Taylor & Francis Ltd/978-1032200514 , Concrete Technology/A M Neville/Pearson Education/978-8131705360 , Construction Materials Their Nature And Behaviour/Marios Soutsos, Peter Domone/Crc Press/978-1498741101864 , Design Of Reinforced Concrete Structures/Subramanian N/Oup India/978-0198086949 , Dynamics Of Structures/Clough,R.W. And Penzien, J/Mcgraw Hil/978-8123926636 , Elasticity And Plasticity: The Mathematical Theory Of Elasticity And The Mathematical Theory Of Plasticity/J.N. Goodier/Dover Publications Inc./ 978-0486806044 , Elements Of Strength Of Materials/Timosenko, S. P., And Young, D.H./Affiliated Eastwestpress Pvt. Ltd/978-8176710190 , Engineering Mechanics Of Solids/Popov, E.P./Pearson Education India/9332550216 , Environmental Engineering/Howard S Peavy, Donald R Rowe/Mcgraw Hill Education/978-9351340263 , Environmental Engineering (Vol. I) Water Supply Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174091208 , Environmental Engineering (Vol. Ii) Sewage Waste Disposal And Air Pollution Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174092304 , Finite Element Analysis: Theory And Programming/C. S. Krishnamurthy/Mcgraw Hill/978-0074622100 , Foundations Of The Theory Of Elasticity, Plasticity, And Viscoelasticity /Eduard Starovoitov And Faig Bakhman Ogli Naghiyev/Apple Academic Press Inc./978-1774631997 , Handbook Of Solid Waste Management/George Tchobanoglous, Frank Kreith /Mcgraw Hill Education/978-0071356237 , Highway Engineering/Khanna & Justo/Nemchand Publisher/8185240930 , Industrial Water Pollution Control/W Wesley Eckenfelder/Mcgraw Hill Education/978-9339220433 , Integrated Design And Environmental Issues In Concrete Technology/K Sakai/Crc Press/978-0367864620 , Intermediate Structural Analysis/Wang, C.K./Mcgraw Hill Education/978-0070702493 , Introduction To Solid Mechanics/Shames, H/Phi/978-9332549906 , Introduction To Traffic Engineering/R Srinivasa Kumar/The Orient Blackswan; South Asian Edition/9386235471 , Matrix And Finite Element Analysis Of Structures/Madhujit Mukhopadhay And Abdul Hamid Sheikh/Anebooks Pvt. Ltd./978-81-8052-075-4 , Microwave-Assisted Concrete Technology/Ong K.C. Gary/Crc Press/978-1138748897 , Prestressed Concrete /Krishnaraju N/Mcgraw Hill Education India/978-9387886209 , Principles Of Adsorption And Adsorption Processes/ Douglas M. Ruthven/Wiley-Interscience/978-0471866060 , Properties Of Concrete/A M Neville/Pearson Education/978-0273755807 , Random Vibrations Of Elastic Systems/Bolotin, V. V./Springer/978-9048182800 , Recent Trends In Solid Waste Management (Advances In Pollution Research)/Balasubramani Ravindran,Sanjay Kumar Gupta/Elsevier - Health Sciences Division/978-0443152061 , Reinforced Concrete: Mechanics And Design, Global Edition /Wight James/Pearson Education Limited/978-1292106007 , Soil Mechanics And Foundation Engineering - Geotechnical Engineering/K.R.Arora/Standard Publisher Dist/8180141128 , Solid Mechanics /Kazimi, S. M.A/Tata Mcgraw-Hill/978-0074517154: ? , Sprayed Concrete Technology/Simon Austin/Crc Press/978-0367865412 , Standard Methods For The Examination Of Water And Wastewater/William C. Lipps, Ellen Burton Braun-Howland, Terry E. Baxter/American Public Health Association/978-0875532998 , Statically Indeterminate Structures/Wang, C.K./Mcgraw Hill Book Company/978-9352604722 , Strength Of Materials/Srinath, L.S, Desayi./Macmillan Publishers India/978-0333923924 , Strength Of Materials, Part 1/Timoshenko, S/Mcgraw Hill/978-8123910307 , Strength Of Materials, Part 2/Timoshenko, S/Mcgraw Hill/978-8123910772 , Structural Dynamics/Mario Paz/Cbs Publications/978-8181287724 , Structural Dynamics- Theory And Application To Earthquake Engg/Anil K Chopra/Pearson Education/978-9353945251 , Structural Dynamics: Vibrations And Systems/Mukhopadhyaya, M./Ane Books /978-8180520907 , Sulfate Attack On Concrete/Jan Sklany/Taylor & Francis Ltd/978-0367447144 , Textbook Of Highway And Traffic Engineering/Saxena S.C /Cbs /978-8123924175 , The Finite Element Method Its Basis & Fundamentals/Zienkiewicz, Taylor And Zhu/Elsevier/978—81-312-118-2 , Theory Of Elasticstability/Timoshenko, S.P. And Gere, J. M./Tata Mcgraw Hill./978-0-07-0702417 , Theory Of Elasticity/Timoshenko And Goodier/Mcgraw Hill/978-0070701229 , Theory Of Elasticity And Plasticity: A Textbook Of Solid Body Mechanics/Antonina Molotnikova And Valentin Molotnikov /Springer Nature/978-3030666248 , Theory Of Plates And Shells/Timoshenko And Kriger/Tata Mcgraw Hill/978-0-07-070125-0 , Traffic & Highway Engineering/Nicholas J. Garber/Cengage India Private Limited/978-8131529430 , Traffic Engineering/R P. Roess (Author), Elena S. Prassas (Author), William R. Mcshane (Author)/Pearson Education/9353434858 , Wastewater To Water: Principles, Technologies And Engineering Design/Makarand M. Ghangrekar/Springer Verlag, Singapore/978-9811940507 , Soil Dynamics And Machine Foundations/Swami Saran/Galgotia Publication S Pvt. Ltd./978-8175157279 , Soil Mechanics And Foundation Engineering/K. R. Arora/Standard Publishers/978-8180141126 , Basic And Applied Soil Mechanics/Gopal Ranjan, Asr Rao/New Age International/9788122440393, , Design Of Steel Structures/N. Subramanian/Oxford University Press/978-0199460915 , Fundamental Concepts Of Earthquake Engineering /Roberto Villaverde/Crc Press/1420064959 , Civil Engineering Drawing /M Chakraborti// , Data Mining Concepts And Techniques /Jiawei Han, Jian Pei,Hanghang Tong/Elsevier/9788131267660 , Data Science In Practice/Tom Alby/Chapman & Hall/9781032505268 , Introduction To Data Science: Practical Approach With R And Python/B. Uma Maheswari, R. Sujatha/Wiley/9789354640506 , Transformers For Natural Language Processing And Computer Vision - Third Edition/Denis Rothman/Packt Publishing/9781805128724 , Generative Deep Learning/ David Foster/Oreilly Media/9781098134181 , Introduction To Machine Learning /Ethem Alpayd?N/Mit Press/9780262043793 , Data Mining With R/Luis Torgo/Taylor And Francis/9780367372453 , Bioinformatics And Functional Genomics/Jonathan Pevsner/Wiley Blackwell Pub/978-1118581780 , Bioinformatics Basics: Applications In Biological Science And Medicine/ Lukas K. Buehler/Crc Press/978-0367392598 , What Is The Name Of This Book?/Raymond M. Smullyan/Dover Publications Inc./978-0486481982 , The Lady Or The Tiger?/Raymond M. Smullyan/Dover Publications Inc./978-0486470276 , The Riddle Of Scheherazade: And Other Amazing Puzzles, Ancient And Modern./Raymond M. Smullyan/Knopf/978-0679446347 , Convex Optimization/Stephen Boyd, Lieven Vandenberghe/Cambridge University Press/978-0521833783 , Genetic Algorithms In Search, Optimization And Machine Learning/David E. Goldberg/Pearson/978-8131709931 , Steganography In Digital Media: Principles, Algorithms, And Applications/Jessica Fridrich/Cambridge/978-0521190190 , Deep Learning From Scratch: Building With Python From First Principles/Seth Weidman/Shroff/Oreilly/978-9352139026 , Wireless Communication Systems /Rajeshwar Dass./Wiley/978-9389583687 , Semiconductor Materials, Devices, And Fabrication, As Per Aicte/Parasuraman Swaminathan/Wiley/978-8126508624 , Introduction To 4G Mobile Communications/Juha Korhonen/Artech House Publishers/978-1608076994 , An Introduction To Lte/Cox Christopher/Wiley/978-1118818039 , Fourth Generation Mobile Communication/Curwen Peter/Springer International Publishing Ag/978-3319022093 , Advanced Wireless Communications: 4G Technologies/Savo G. Glisic/Wiley–Blackwell/978-0470867761 , 4G Wireless Communication Networks: Design Planning And Applications/Johnson I. Agbinya, Mari Carmen Aguayo-Torres, Ryszard Klempous/River Publishers/978-8792982711 , Fundamentals Of Lte/Rews, Rias Muhamed, Arunabha Ghosh, Jun Zhang, Jeffrey G./Pearson/978-9353062392 , 5G Mobile Communications/Wei Xiang, Kan Zheng, Xuemin (Sherman) Shen/Springer International Publishing Ag/978-3319342061 , 5G Mobile Core Network: Design, Deployment, Automation, And Testing Strategies/Rajaneesh Sudhakar Shetty/Springer India/978-1484283288 , 5G Mobile And Wireless Communications Technology/Afif Osseiran, Jose F. Monserrat, Patrick Marsch, Mischa Dohler, Takehiro Nakamura/Cambridge University Press/978-1107130098 , Towards 5G: Applications, Requirements And Candidate Technologies/Rath Vannithamby, Shilpa Talwar/Wiley/978-1118979839 , Fundamentals Of 5G Mobile Networks/Jonathan Rodriguez/Wiley/978-1118867525 , A Course In Electrical And Electronic Measurements And Instrumentation/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited;/978-8177001006 , A Course In Electrical Machine Design/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited /978-8177001013 , A Course In Electrical Technology (Basic Electrical Engineering Volume I)/J.B.Gupta/S.K. Kataria & Sons/81-85749-29-9 , A First Course On Electrical Drives/S.K.Pillai/New Age International Publishers/978-8122433616 , A Text Book Of Electrical Technology (Vol.1)/B.L.Theraja, A.K.Theraja/S.Chand Technical/9788121924405 , A Textbook Of Electrical Technology Volume Ii : Ac And Dc Machines/B.L.Theraja, A.K.Theraja/S Chand/978-8121924375 , Advanced Electrical Technology/H. Cotton/Reem Publications Pvt. Ltd. /978-8190630719 , An Integrated Course In Electrical Engineering/J.B.Gupta/S.K. Kataria & Sons/9-789350143681 , An Introduction To Analog And Digital Communication Systems/ Simon Haykin, Michael Moher /Wiley/978-8126536535 , An Introduction To The Principles Of Digital Communications/N.B.Chakraborti, A.K.Datta/New Age International Publishers/978-8122420838 , Analog Communication Systems/Sanjoy Sharma/S.K. Kataria & Sons/978-9350143797 , Artificial Intelligence And Intelligent Systems/N.P. Padhy/Oxford University Press/978-0195671544 , Artificial Neural Networks/B. Yegnanarayan/Prentice-Hall Of India Pvt. Ltd., New Delhi/ 978-8120312531 , Automatic Control System/ B. C. Kuo/ Prentice Hall Of India/9788120309685 , Automatic Control Systems (With Matlab Programs)/S. Hasan Saeed/Arihant Publisher/978-8190691925 , Basic Electrical Engg./D.P. Kothari & I.J. Nagrath/Mcgraw-Hill/9780070146112 , Basic Electrical Engg./V.K.Mehta, Rohit Mehta/S.Chand /978-8121908719 , Basic Electrical Engineering/A.E Fitzgerald, David E. Higginbotham, Arvin Grabel/ Mcgraw Hill Education/978-0070682566 , Circuit Theory (Analysis & Synthesis)/A.Chakraborti/Dhanpat Rai & Co./9788177000009 , Circuit Theory & Network/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9780071329040 , Communication Systems/Sekar, V. Chandra//978-0198078050 , Control System Engineering (Student Edition)/Norman Nise/John Wiley & Sons/978-8126537280 , Control Systems - I /S. Hasan Saeed/S.K. Kataria & Sons/978-9350141335 , Control Systems Engineering/I.J. Nagrath &M.Gopal/New Age International Pvt Ltd Publishers/9789386070111 , Design And Applications Of Analog Integrated Circuits/Soclof/Phi Learning Private Limited/978-81-203-2552-4 , Digital Communications/Sanjoy Sharma/S.K. Kataria & Sons/978-9350142684 , Digital Control Engineering/M. Gopal/New Age International Publishers/978-8122436617 , Digital Control Systems/B.C.Kuo/Oxford University Press/978-0198083542 , Digital Design/M. Morris Mano/Prentice Hall/978-0132774208 , Digital Electronics /G.K.Kharate/Oxford University Press/9-780198061830 , Digital Integrated Electronics/H. Taub And D. L. Schilling/Mcgraw Hill Education/978-0070265080 , Digital Signal Processing/Monson H Hayes/Tata Mcgraw - Hill Education/978-0070153868 , Digital Signal Processing/P.Ramesh Babu/Scitech Publications/978-8183710817 , Digital Signal Processing/B. Kumar/New Age International Publishers/978-8122436099 , Digital Signal Processing: A Computer Based Approach/S. K. Mitra/Mcgraw Hill Education/978-1259098581 , Direct Energy Conversion/Kettani, M. Ali/Addison-Wesley/ 97-80201036633 , Direct Energy Conversion/Stanley W. Angrist/Allyn And Bacon/978-0205077588 , Distributed Generation: Induction And Permanent Magnet Generators/Loi Lei Lai, Tze Fun Chan/Wiley/978-0470062081 , Distributed Generation: The Power Paradigm For The New Millennium/Anne-Marie Borbely, Jan F. Kreide/Crc Press/978-1420042399 , Electric And Hybrid Vehicles/Tom Denton/Routledge/9781138842373 , Electric Circuits /David. A. Bell/Oxford University Press/9780195694284 , Electric Energy Systems Theory-An Introduction/Olle I. Elgerd/Tata Mcgraw Hill/9780070992863 , Electric Machines/ I. J. Nagrath And D. P. Kothari/Tata Mcgraw Hill/978-0070699670 , Electrical Circuit Analysis (Including Passive Network Synthesis)/C.L.Wadhwa/New Age International Publishers/978-8122418521 , Electrical Engineering Fundamentals/Vincent Del Toro/Phi Learning Private Limited/978-8120305991 , Electrical Engineering Materials/T.K.Basak/New Age International Publishers/978-8122427738 , Electrical Machinery/Dr. P.S.Bimbhra/Khanna Publishers/978-8174091734 , Electrical Machinery /S. K. Sen/Khanna Publishers /978-8174091529 , Electrical Machines/R.K.Rajput/Laxmi Publications(P) Ltd./978-8131804469 , Electrical Machines /S.K.Bhattacharya/Tata Mcgraw-Hill Education/978-9332902855 , Electrical Measurements And Measuring Instruments/ E.W Golding, F.C Widdis/Reem Publications Pvt. Ltd/978-8190630726 , Electrical Power System Quality/R.C.Dugan/Tata Mcgraw-Hill Education, 2003/978-1259005572 , Electrical Power Systems/Ashfaq Husain/Cbs Publishers & Distributors/978-8123914480 , Electromagnetic Fields & Waves96/Sarwate V.V./New Age/81-224-0468-5 , Electromagnetic With Application/J. D. Krauss/Tata Mcgraw Hill/9780070702400 , Electromagnetics/B.B.Laud/New Age International Publishers/978-8122430554 , Electromagnetism – Theory And Applications/Ashutosh Pramanik/Prentice-Hall Of India/978-8120319578 , Electronic Devices And Circuit Theory/R. Boylestad And L. Nashelsky/Prentice Hall Publishing Co/978-0132504577 , Electronic Devices And Circuits/J. Millman And C. C. Halkias/Mcgraw Hill Education/978-0070423800 , Electronic Instrumentation/H.S.Kalsi/Mcgraw Hill Education/978-0070702066 , Elements Of Advanced Quantum Theory/J.M. Ziman/Camridge University Press/521-07458-4 , Elements Of Electrical Power Station Design/M.V.Deshpande/Prentice Hall India Learning Private Limited /978-8120336476 , Elements Of Photonics Vol-1 /Keigo Lizuka/Wiley-Interscince/0-471-83938-8 , Elements Of Power System Analysis/W.D. Stevenson/Mcgraw Hill Higher Education/978-0070665842 , Energy Economics: Concepts, Issues, Markets And Governance/Subhes C. Bhattacharyya/ Springer/978-1447174707 , Energy Science Principles, Technologies And Impact/J. Andrews, N. Jelley/Oxford University Press/978-0198755814 , Energy Technology - Nonconventional, Renewable & Conventional/S.Rao, Dr. B.B.Parulekar/Khanna Publishers/97-88174090401 , Energy Technology (Non Conventional, Renewable And Conventional)/Prof. Sunil S. Rao And Dr. B.B. Parulekar/Khanna Publishers/978-81-7409-040-9 , Engineering Circuit Analysis/W. H. Hayt , J. Kemmerly /Mcgraw Hill Education/978-1259098635 , Engineering Electromagnetic/W. H. Hayt & J. A. Buck/Mcgraw-Hill/978-9353169725 , Engineering Electromagnetics/Hayat/Tmh/0-07-061223-4 , Engineering Optimization Theory And Practice/Singiresu S. Rao/New Age International Publishers/978-8122427233 , Engineering Thermodynamics/P.K.Nag/ Mcgraw Hill Education/978-9352606429 , Explanations / Solutions To An Integrated Course In Electrical Engineering (With About 15,000 Objective Type Questions & Answers) /J.B.Gupta/S.K. Kataria & Sons/978-9350146668 , Facts Controllers In Power Transmission And Distribution/K.R. Padiyar/New Age International Publishers/978-8122421422 , Fiber Optics Essentials/K. Thyagarajan & Ajoy Ghatak/Wiley-Interscince/978-0-470-09742-7 , Fiber Optics Through Experiments Paperback – 2011/Ajoy Ghatak, M. R. Shenoy /Viva Books (2011)/978-8130918112 , Fiber-Optic Communication Systems/Govind P. Agrawal/Wiley/978-8126513864 , Fibre Optics And Optoelectronics/R.P.Khare/Oxford University Press/9-780195669305 , Flexible Ac Transmission Systems/Yong Hua Song, Allan T. Johns/ Laxmi Publications /978-8190858809 , Fundamentals Of Digital Circuits/A. Anand Kumar/Prentice-Hall Of India Pvt. Limited/978-8120352681 , Fundamentals Of Electric Circuits/Charles K. Alexander, Matthew N. O. Sadiku/Mcgraw Hill Education (India) Private Limited/978-9355320162 , Fundamentals Of Microprocessors And Microcontrollers/B. Ram/Dhanpat Rai Publications (P) Ltd/978-9383182107 , Fundamentals Of Optical Wave Guides/Katsunari Okamoto/Elsevier/978-0-12-525-096-2 , Fundamentals Of Photonics /Bahaa E. A. Saleh, Malvin Carl Teich/ John Wiley & Sons, Inc./0-471-2-1374-8 , Fundamentals Of Power Electronics/Robert W. Erickson, Dragan Maksimovic/Springer Us/978-1-4757-0559-1 , Generation Distribution And Utilization Of Electrical Energy/C.L. Wadhwa/New Age International Publishers/978-8122428216 , Getting Started With Matlab/Rudra Pratap/Oxford University Press/978-0198069195 , Goldings Electrical Measurements And Measuring Instruments/Golding & Widdis/Medtech Publishers/978-9387210349 , Handbook Of Energy Conservation, Vol. 1/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912066 , Handbook Of Energy Conservation, Vol. 2/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912073 , High Voltage Engineering/C.L.Wadhwa/New Age International Publishers/978-8122430905 , High Voltage Engineering/M.S Naidu & V Kamaraju/Mcgraw Hill Education/978-1259062896 , High Voltage Engineering: Problems & Solutions/R.D. Begamudre/New Age International Publishers/978-8122426182 , Hvdc Power Transmission Systems/K.R. Padiyar/New Age International Publishers/978-8122437850 , Industrial Energy Conservation Techniques : Concepts, Applications And Case Studies /K. Nagabhushan Raju/Atlantic Publishers And Distributors (P) Ltd/978-8126907748 , Industrial Instrumentation/Donald P. Eckman/Cbs Publisher/978-8123908106 , Industrial Instrumentation/K.Krishnaswamy, S. Vijayachitra/New Age International Publishers/978-8122427509 , Industrial Instrumentation, Control And Automation/Mukhopadhay, Sen & Deb/Jaico Publishing House/978-8184954098 , Instrumentation And Control/Patranabis/Phi Learning Private Limited/978-81-203-4246-0 , Introduction To Digital Signal Processing/J.R. Johnson/ Prentice Hall India Learning Private Limited /978-8120307605 , Introduction To Fiber Optics (English) 1St Edition/Ajoy Ghatak , K. Thyagarajan/Cambridge University Press-New Delhi/97-88175960626 , Introduction To Quantum Mechanics/David J. Griffiths/Prentice Hall/0-13-124405-1 , Introduction To Quantum Mechanics/A.C. Philips/John Wiley & Sons, Inc./0-470-85323-9 , Introduction To Solid State Physics/ Charles Kittel /Wiley & Sons/978-8126535187 , Lasers And Non-Linear Optics/B.B.Laud/New Age International Publishers/978-8122430561 , Linear Integrated Circuits/D. Roy Choudhury, Shail B. Jain/New Age International Publishers/978-8122430981 , Matrix Analysis Of Electrical Machines/Ashoke Kumar Mukhopadyhay/New Age International Publishers/978-8122432398 , Microcomputer Systems: The 8086/8088 Family/I. Liu, G. A. Gibson/ Prentice Hall India Learning Private Limited/978-8120304093 , Microelectronic Circuits: Theory And Applications/A.S. Sedra And K.C. Smith/Oxford University Press/978-0199476299 , Microelectronics/J. Millman And A. Grabel/Mcgraw Hill Education/978-0074637364 , Microprocessor Architecture, Programming And Applications With The 8085A/8080A/Ramesh S. Gaonkar/Wiley Eastern Ltd./978-0852262979 , Microprocessors Interfacing/Douglas Hall/Mcgraw Hill Education/978-1259006159 , Modern Digital And Analog Communication Systems/B.P.Lathi/Oxford University Press/978-0198073802 , Modern Electronic Instrumentation And Measurement Techniques /A D Helfrick; W D Cooper/ Prentice Hall India Learning Private Limited/?978-9332556065 , Modern Power System Analysis/I.J. Nagrath And D.P. Kothari/Mcgraw Hill Education/978-0071077750 , Modern Quantum Mechanics /J.J.Sakurai/Addison -Wesley Publishing Company/0-201-53929-2 , Network Analysis And Synthesis/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9781259081422 , Network Analysis And Synthesis/Franklin F. Kuo /Wiley/978-8126510016 , Network Analysis And Synthesis (Including Linear System Analysis)/C.L.Wadhwa/New Age International Publishers/978-8122420364 , Networks And Systems/D. Roy Choudhury/New Age International Publishers/978-8122427677 , Neural Networks In Computer Intelligence /F. Limin/Mcgraw Hill Education/978-0070532823 , Neural Networks, Fuzzy Logic And Genetic Algorithms: Synthesis And Applications/S. Rajasekaran And G.A. Vijaylakshmi Pai,/Prentice-Hall Of India Pvt. Ltd., New Delhi/978-8120321861 , Non Conventional Energy Resources/D.S. Chauhan, S.K.Srivastava/New Age Int.(P) Ltd/978-81-224-3399-9 , Non-Conventional Energy Resources/B.H. Khan/Tata Mcgraw Hill/978-0070142763 , Non-Conventional Energy Resources/D.S. Chauhan/New Age International Publishers/978-8122433999 , Non-Conventional Energy Sources/G.D. Rai/Khanna Publishers/9-788174090737 , Nonlinear Fiber Optics/Govind P. Agrawal/Optics And Photonics/N/A , Nonlinear Optics /Robert W. Boyd/Academic Press/0-12-121682-9 , Objective Electrical Technology/V.K.Mehta, Rohit Mehta/S. Chand Publishing/978-9355014467 , Op-Amps And Linear Integrated Circuits/Gayakwad/Phi Learning Private Limited/978-81-203-2058-1 , Operational Amplifiers And Linear Ics/David. A. Bell/Oxford University Press/978-0195696134 , Optical Electronics /A.K.Ghatak & K.Thyagarajan/Camridge University Press/0-521-30643-4 , Optical Waves In Crystals/Amnon Yariv & Pochi Yeh/Wiley-Interscince/0-471-09142-1 , Optimization Of Power System Operation/Jizhong Zhu/Wiley/978-1-118-85415-0 , Parker Smiths 500 Solutions Of Problems In Electrical Engineering (Part 1)/V.C Nateshan/Cbs /N/A , Performance And Design Of Ac Machines/M. G. Say/Cbs Publishers/978-8123910277 , Photonics/Amnon Yariv & Pochi Yeh/Oxford University Press/978-0-19-517946-0 , Power Electronics/Dr. P. S. Bhimbra/Khanna Publisher/978-81-7409-279-3 , Power Electronics: Converters, Applications, And Design/Ned Mohan, Tore M. Undeland, William P. Robbins/Wiley India/978-8126510900 , Power Electronics: Devices, Circuits And Applications/Muhammad H Rashid/Pearson Education/978-9332584587 , Power Electronics: Essentials & Applications/L. Umanand/Wiley/978-8126519453 , Power Generation, Operation, And Control/Allen J. Wood, Bruce F. Wollenberg/John Wiley & Sons/978-8126508389 , Power Plant Engineering/Arora & Domkundwar/Dhanpat Rai & Co. (P) Limited/978-8177001952 , Power Plant Engineering/A.K.Raja, Amit Prakash Srivastava, Manish Dwivedi/New Age International Publishers/978-8122418316 , Power Plant Technology/M.M.El-Wakil/Mcgraw Hill Education/978-0070702448 , Power System Analysis/J.J.Grainger, W.D.Stevenson/Tata Mcgraw-Hill/978-0070612938 , Power System Analysis: Operation And Control/ Abhijit Chakrabarti, Sunita Halder/Phi Learning Pvt. Ltd./ 978-8120340152 , Power System Optimization: Stability And Control/K. R. Padiyar/Anshan Ltd./978-1904798019 , Power System Optimization/D .P. Kothari And J.S Dhillon/Prentice Hall India Learning Private Limited/?978-8120340855 , Power System Prorection And Switchgear/B. Ravindranath And M. Chander/New Age International Publishers/978-8122430325 , Power System Protection/S. P. Patra, S. K. Basu, S. Choudhuri/Oxford & Ibh Publishing Co./N/A , Power System Protection And Communications/Akhter Kalam/New Age International Publishers/978-8122427417 , Power System Protection And Swichgear/B. Ravindranath, M. Chander/New Age International Publishers/978-8122430325 , Power System Restructuring And Deregulation/Loi Lei Lai/John Wiley & Sons Ltd /978-8126547234 , Power System Stability Vol-I/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power System Stability And Control/Prabha Kundur/Tata Mcgraw-Hill Education Private Limited/978-0070635159 , Power System Stability Vol-Ii/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power Systems Analysis/ Arthur Bergen, Vijay Vittal / Pearson/978-0136919902 , Principles Of Electromagnetics/Matthew N.O. Sadiku/Oxford University Press/9780198062295 , Principles Of Electronic Instrumentation/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Principles Of Industrial Instrumentation/D. Patranabis/Mcgraw Hill Education/978-0070699717 , Principles Of Power Systems/V.K.Mehta, Rohit Mehta/S.Chand & Co./978-8121924962 , Principles Of Process Control/ D. Patranabis/Tata Mcgraw Hill/978-0071333252 , Principles Of Signal Processing And Linear Systems/B.P.Lathi/Oxford University Press/978-0198062288 , Problems And Solutions In Power Systems/Abhijit Chakrabarti /Abhijit Chakrabarti /978-9334032581 , Problems In Electrical Engineering(Power Engineering And Electronics With Answers Partly Solved In S.I. Units)/N. N. Parker Smith/Cbs Publisher/978-8123908588 , Process Control (Concepts, Dynamics & Applications)/S.K.Singh/Phi Learning Private Ltd./978-8120336780 , Process Control (Principles & Applications)/Surekha Bhanot/Oxford University Press/978-0195693348 , Process Dynamics And Control/D.E. Seborg, T.F. Edgar And D.A. Mellichamp/Wiley/978-8126541263 , Process Systems Analysis And Control/D.R. Coughanowr And L.B. Koppel/Mcgraw-Hill/978-0070851122 , Pulse Width Modulation For Power Converters: Principles And Practice/D. Grahame Holmes, Thomas A. Lipo/Wiley Ieee Press/978-0-471-20814-3 , Quantum Optics/Harry Paul/Camridge University Press/978-0-511-19475-7 , Reliability And Life Estimation Of Power Equipment/T.S.Ramu And Chakradhar Reddy/New Age International Publishers/978-8122426113 , Renewable Energy For Sustainable Future/Godfrey Boyle/Oxford University Press/978-0199681273 , Research Insights: A Handbook On Grant Writing And Program Management/ Rajiv K. Tayal/Atlantic Publishers And Distributors Pvt Ltd./978-8126935451 , Semiconductor-Laser Fundamentals/Weng W. Chow & Stephen W. Koch/Springer/3-540-64166-1 , Sensors And Transducers/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Signals And Systems/H. P. Hsu/Mcgraw Hill Education (India) Private Limited/978-0070669185 , Signals And Systems/A.V. Oppenheim, Schafer, R. W, A.S. Willsky And I.T. Young/ Pearson Education India/9332550239 , Smart Grid Technology And Application/Janaka Ekanayake, Kithsiri Liyanage, Jianzhong Wu, Akihiko Yokoyama And Nick Jenkins/Wiley Publications/978-0-470-97409-4 , Smart Grid: Concepts To Design/K. S. Manoj/Notion Press/9781646780006 , Smart Grid: Fundamental Of Design And Analysis/James Momoh/Wiley Publication/978-8126558124 , Solar Cell Device Physics/Stephen Fonash/Academic Press/978-0080912271 , Solar Cells: Operating Principles, Technology, And Systemapplications/Martin A. Green/Prentice-Hall/978-0138222703 , Solar Electricity Generation/S. Bhattacharjee/ Narosa Publishing House/97-88184874044 , Solar Energy/S.P. Sukhatme, J K Nayak/Tata Mcgraw Hill/978-9352607112 , Solar Photovoltaics: Fundamentals, Technologies And Applications/Chetan Singh Solanki/Phi Learning/978-8120351110 , Solid State Physics/A.J. Dekker/ Macmillan/978-0333106235 , Solid State Physics/ S.O. Pillai /New Age International Private Limited/978-9389802313 , Sustainable Energy Management/Mirjana Radovanovi? (Golusin),Stevan Popov,Sinisa Dodic /Elsevier/978-0124159785 , Taubs Principles Of Communication Systems /H. Taub And D.L. Shilling/Mcgraw Hill Education/978-0070648111 , The 8051 Microcontroller And Embedded Systems/Muhammed Ali Mazidi And Janice Gillispie Mazidi/Pearson Education India/978-0138610227 , The Theory Of Optics/Paul Drude/Longmans, Green & Co./N/A , Theory & Performance Of Electrical Machines/J.B.Gupta/S.K. Kataria & Sons/978-9350142776 , Thermal Engineering/R.K.Rajput/ Laxmi Publications/978-8131808047 , Understanding Facts: Concepts And Technology Of Flexible Ac Transmission Systems/Narain G. Hingorani, Laszlo Gyugyi/Wiley India Pvt Ltd./978-8126530403 , Signals And Systems /Ramesh Babu/Scitech Publications/978-81-8371-288-0 , Fundamentals Of Industrial Instrumentation /Barua/Wiley India/9788126528820 , Bioinstrumentation /Fulekar/Wiley India/9789389520286 , Wileys Gate Instrumentation Engineering Chapter-Wise Solved Papers (2000-2020)/Gupta/Wiley India/9788126558698 , Electronic Measurement & Instrumentation /Imam/Wiley India/9789389583021 , Electrical Measurements And Measuring Instruments/Kamakshaiah/Wiley India/9789389447521 , A Treatise On Instrumentation Engineering /Padmanabhan/Wiley India/9789389633832 , Instrumentation And Process Control /Prasad/Wiley India/9789389307191 , Biomedical Electronics And Instrumentation Made Easy /Sawhney/Wiley India/9789389795943 , Medical Instrumentation 5Ed: Application And Design, An Indian Adaptation /Webster/Wiley India/9789354249150 , Lasers And Optical Instrumentation /Nagabhushana/Wiley India/9789389698756 , Automatic Control Engineering /Gupta/Wiley India/9789389583748 , Power System Analysis: Operation And Control, 2Ed/Jena/Wiley India/9789389520415 , Process Control Engineering /Krishna/Wiley India/9789389633429 , Quality Control/Kulkarni/Wiley India/9788126519071 , Control Engineering/Kuttan/Wiley India/9789389520064 , Digital Control, W/Cd /Moudgalya/Wiley India/9788126522064 , Nises Control Systems Engineering, Wiley India Ed/Nise/Wiley India/9788126571833 , Control Systems /Padmanabhan/Wiley India/9789389633375 , Control Engineering/Ramachandran/Wiley India/9788126522880 , Power System: Operation & Control/Rao/Wiley India/9788126534418 , Matlab With Control System, Signal Processing And Image Processing Toolboxes, W/Cd /Sivanandam/Wiley India/9788126554751 , Statistical Quality Control: A Modern Introduction, 6Ed /Montgomery/Wiley India/9788126525065 , Robotics /Appu/Wiley India/9789389583281 , Fuzzy Sets And Fuzzy Logic With Engineering Applications, 4Ed, An Indian Adaptation /Rose/Wiley India/9788126502608 , Natural Language Processing/Kumar/Wiley India/9789389307597 , Optimization Techniques /Malik/Wiley India/9789389698725 , Artificial Intelligence For Dummies/Mueller/Wiley India/9788126576104 , Big Data Analytics Using Artificial Intelligence Technologies /Dixit/Wiley India/9789391029685 , Artificial Intelligence: Concepts And Applications /Goel/Wiley India/9788126519934 , Artificial Intelligence: Making A System Intelligent /Jain/Wiley India/9788126579945 , Artificial Intelligence/Kumar/Wiley India/9789389795134 , Process Dynamics And Control, 4Edan Indian Adaptation /Seborg/Wiley India/9789354248429 , Digital Control/Moudgalya/Wiley India/9788126522064 , An Advanced Approach To Data Interpretation For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9358702330 , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9355012326 , Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9355011534 , Objective General English/R.S. Aggarwal/S Chand Publishing/978-9355015075 , The Magic Of The Lost Temple/Sudha Murty/Penguin Books India/978-0143333166 , Samsara: Enter The Valley Of The Gods/Saksham Garg/Penguin/978-0143458289 , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery/Brianna Wiest/Amaryllis/978-9355434142 , I Dont Love You Anymore: Moving On And Living Your Best Life/Rithvik Singh/Ebury Press/978-0143469131 , Ancient India/Rs Sharma/Old Ncert/N/A , History Of Medieval India/Satish Chandra/Old Ncert/N/A , A Brief History Of Modern India/Spectrum Publications/Spectrum/N/A , India’S Struggle For Independence/Bipan Chandra/Penguin/N/A , Certificate Physical And Human Geography/G.C. Leong/Oxford University Press/N/A , India: A Comprehensive Geography/D.R. Khullar/Kalyani Publishers/N/A , Indian Polity/M. Laxmikanth/Mcgraw Hill/N/A , Indian Economy/Ramesh Singh/Mcgraw Hill/N/A , Environment/Shankar Ias/Shankar Ias Academy/N/A , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/N/A , Disaster Management/R. Subramanian/Vikas Publishing/N/A , Internal Security/M.Karthikeyan/Tata Mcgraw Hill/N/A , Lexicon For Ethics, Integrity & Aptitude/Niraj Kumar/Pearson/N/A , Ethics, Integrity, And Aptitude/Subba Rao And P.N. Roy Chowdhury/Access Publishing/N/A , Principles Of Mathematical Analysis/Walter Rudin/Mcgraw-Hill Education/978-0070856134 , Real And Complex Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619876 , Functional Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619883 , Mathematical Analysis/Tom M. Apostol /Narosa/978-8185015668 , Real Analysis/Royden/Pearson Education India/978-9332551589 , Analysis I/Terence Tao/Hindustan Book Agency/978-9380250649 , Complex Analysis/Ahlfors L V/Mcgraw Hill/978-1259064821 , Complex Variables And Applications/James Ward Brown, Ruel V. Churchill/Mcgraw Hill/978-9354600364 , Functions Of One Complex Variable I/John B. Conway/Springer/978-0387903286 , Algebraic Topology/Allen Hatcher /Cambridge University Press/978-0521795401 , Topology/James Munkres/Pearson Education/978-9353432775 , Introduction To Topology And Modern Analysis /George Simmons/Mcgraw Hill Education/978-0070597846 , Introduction To Analytic Number Theory/Tom M. Apostol /Springer/978-1-4419-2805-4 , Topology Of Metric Spaces/S. Kumaresan/Narosa/978-81848705 , Topics In Algebra/I.N. Herstein/Wiley/978-8126510184 , Algebra/M Artin/Pearson Education India/978-9332549838 , Abstract Algebra/David S. Dummit, Richard M. Foote/Wiley/978-8126532285 , A First Course In Abstract Algebra/J.B. Fraleigh/Narosa Publishing House Pvt Ltd/978-8185015705 , Contemporary Abstract Algebra/Joseph A Gallian/Cengage India Private Limited/978-9353502522 , Linear Algebra/Kenneth M Hoffman And Ray Kunze/Prentice Hall India Learning Private Limited/978-9332550070 , Matrix Analysis/Roger A. Horn, Charles R. Johnson/Cambridge University Press/978-0521548236 , Topics In Matrix Analysis/Charles R. Johnson, Roger A. Horn/Cambridge University Press/978-0521467131 , Matrix Analysis/Rajendra Bhatia/Springer/978-0387948461 , Introduction To Linear Algebra/Gilbert Strang /Wellesley-Cambridge Press/978-09802327-7-6 , Linear Algebra And Learning From Data/Gilbert Strang/Wellesley-Cambridge Press/978-06921963-8-0 , Linear Algebra: A Geometric Approach/S. Kumaresan/Prentice Hall India Learning Private Limited/978-8120316287 , Differential Equations/Shepley L. Ross /Wiley/978-8126515370 , Theory Of Ordinary Differential Equations/Earl Coddington, Norman Levinson/Mcgraw Hill Education/978-0070992566 , Differential Equations: Theory - Technique And Practice /George Simmons/Mcgraw Hill Education/978-0070616097 , Introduction To Graph Theory/West/Pearson Education India/978-9332549654 , Graph Theory/Frank Harary/Narosa Publishing House/978-8185015552 , Spectral Graph Theory/Fan R. K. Chung/American Mathematical Society/978-0821803158 , Graphs And Matrices/Ravindra B. Bapat/Springer London Ltd/978-1848829800 , Spectra Of Graphs/Andries E. Brouwer, Willem H. Haemers/Springer/978-1489994332 , The Feynman Lectures On Physics Vol 3/Richard P. Feynman/Addison-Wesley/978-8185015842 , Quantum Computation And Quantum Information/M. A. Nielsen And I. L. Chuagn/Cambridge University Press/978-1107619197 , Principles Of Quantum Computation And Information: A Comprehensive Textbook/Giuliano Benenti, Giulio Casati/World Scientific Publishing Co Pte Ltd/978-9813279995 , Quantum Computing Explained/David Mcmahon/Wiley-Ieee Computer Society Pr/978-0470096994 , Coding Theory: A First Course/San Ling/Cambridge English/978-1108717540 , Elements Of Information Theory/Joy A. Thomas Thomas M. Cover/Wiley/978-8126541942 , First Course In Information Theory/Raymond W. Yeung/Springer Low Price Edition/978-8184897036 , Machine Learning: A Probabilistic Perspective/Kevin P. Murphy /The Mit Press/978-0262018029 , Introduction To Data Mining/Pang-Ning Tan Michael Steinbach Anuj Karpatne Vipin Kumar/Pearson/978-9354491047 , Data Warehousing: Fundamentals For It Professionals/Paulraj Ponniah/Wiley/978-8126537297 , An Introduction To Probability Theory And Its Applications Vol I/William Feller/Wiley/978-8126518050 , An Introduction To Probability Theory And Its Applications Vol Ii/William Feller/John Wiley & Sons Inc/978-8126518067 , A Textbook Of Algebra/Sudesh K Shah, Subhash Chand Garg/S.Chand/978-9352710829 , Introduction To Differential Geometry Of Space Curves And Surfaces/Taha Sochi/Create Space/1546735895 , Differential Geometry Of Manifolds/U. C. De, A. A. Shaiks/Narosa Publisher/ 978-8173197772 , Differential Geometry Of Manifolds/Lovett Stephen/Taylor & Francis Ltd/978-0367180461 , Adventures In Stochastic Processes/Sidney I. Resnick/Springer Science & Business Media/978-1461203872 , Statistical Methods/Kapil Sharma/Oxford Book Co./978-9350304693 , Statistics For Business And Economics/Dr. G.P. Yadav/Oxford Book Co./8185771545 , Statistics For Management /Ashish J. Dave/Oxford Book Co./978-9350300732 , Statistics For Management And Economics/Dr. G.P. Yadav/Oxford Book Co./978-8183765688 , Strategic Methods And Concepts Of Statistics/R.K. Jacob/Oxford Book Co./978-8183765800 , Vector Calculus/Dr. Rakesh Kumar Pandey/Oxford Book Co./978-9350304716 , A Course Of Mathematical Analysis/P K Mittal & /S.Chand/978-8121904728 , A Textbook Of Algebra/Subhash Chand Garg /S.Chand/978-9352710829 , A Textbook Of Discrete Mathematics/Dr. Swapan Kumar Sarkar/S.Chand/9788121922326 , A Textbook Of Vector Analysis/P K Mittal & /S.Chand/9788121922432 , A Textbook On Dynamics/M Ray & G C Sharma/S.Chand/9788121903424 , Advanced Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908931 , Analytical Solid Geometry/P K Mittal & Shanti Narayan/S.Chand/9788121926614 , Applied Mathematics/N C Srinivas & Ch V Ramana Murthy/S.Chand/9788121920827 , Differential Calculus/Shanti Narayan & P K Mittal/S.Chand/9788121904711 , Differential Calculus For Competetions/Shanti Narayan/S.Chand/978-8121925136 , Dynamics/Dr. M.D. Raisinghania/S.Chand/978-8121926492 , Elementary Statistics/H C Saxena/S.Chand/978-8121909259 , Elements Of Real Analysis/Dr. M.D. Raisinghania & Shanti Narayan/S.Chand/9788121903066 , Experimental Statistics/Dr. K. Balaji/S.Chand/9788121935661 , Fourier Series And Integral Transforms/Dr. V. Ramesh Babu & S. Ranganatham/S.Chand/9789384319090 , Integral Calculus/P K Mittal & Shanti Narayan/S.Chand/9788121906814 , Integral Calculus For Competetion/P K Mittal & Shanti Narayan/S.Chand/9788121925358 , Integral Equations And Boundary Value Problems/Dr. M.D. Raisinghania/S.Chand/9788121928052 , Mathematical Statistics/J. N. Kapur & H.C. Saxena/S.Chand/9788121912464 , Mathematics For Degree Students/Dr. U.S. Rana/S.Chand/9788121941013 , Algebraic Topology: An Introduction/Naseer Khan/Oxford Book Co./978-9350303344 , Analysis On Manifolds: A Modern Approach To Mathematics & Physics/V.G. Gupta/Oxford Book Co./978-9350304242 , Applied Combinatorics /Luis J. Green/Oxford Book Co./978-9350304556 , Applied Partial Differential Equations/Dr. F.D. Wade/Oxford Book Co./978-8189473433 , Applied Statistics For Economics And Business/G.P. Gupta/Oxford Book Co./978-9350303825 , Basics Of Bioinformatics/Narayan Dubey/Oxford Book Co./978-9383096893 , Business Statistics For International Trade/Ashish J. Dave/Oxford Book Co./978-9383101030 , Calculus For Computer Graphics/Gopal Narayan/Oxford Book Co./978-9383096916 , Calculus With Vectors/Luis J. Green/Oxford Book Co./978-9383096053 , Computing Fundamentals/Gopal Narayan/Oxford Book Co./978-9350304624 , Elementary Bioinformatics/Dr. Satish Kumar Sinha/Oxford Book Co./978-9350304266 , Environmental Statistics With R/Dr. Manendra Kumar/Oxford Book Co./978-9350301333 , Essential Statistics For Business And Economics/Ashish J. Dave/Oxford Book Co./978-9383096176 , Essentials Of Bioinformatics/Dr. Ashish Gulwe/Oxford Book Co./978-9350303603 , Fuzzy Logic, Neural Network And Genetic Algorithms Handbook/Jan Bundschuh/Oxford Book Co./978-9383096039 , Handbook Of Bioinformatics/S.G. Sandhu/Oxford Book Co./978-8193470404 , Mathematical Logic/Dr. Savita Mishra/Oxford Book Co./978-9350304532 , Mathematical Modelling/Naseer Khan/Oxford Book Co./978-9382629733 , Mathematical Physics/Hilary D. Brewster/Oxford Book Co./978-9350303412 , Optimization Theory: Techniques Of Operation Research/V.G. Gupta/Oxford Book Co./978-9350304334 , Mechanics/Muthamizh Jayapragasam, Laxmi Duraipandian/S.Chand/9788121902724 , Ordinary And Partial Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908924 , Probability And Quening Theory/P Kandasamy & /S.Chand/9788121923569 , Theory Of Functions Of A Complex Variable/P K Mittal & Shanti Narayan/S.Chand/9788121906395 , Vector Algebra/P K Mittal & Shanti Narayan/S.Chand/9788121909525 , Vector Analysis/Kayalal Pachaiyappa & P Duraipandian/S.Chand/9789384319694 , Statics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173810275 , Rigid Dynamics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173812248 , Higher Algebra[Classical And Modern]/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173811043 , Numerical Analysis With Elements Of Computer Science/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173817557 , Mathematical Analysis/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./978-8173817809 , Numerical Analysis/Kalyan Mukherjee/New Central Book Agency Pvt. Ltd./978-8173815201 , Linear Programming And Theory Of Games/Pyari Mohan Karak/New Central Book Agency Pvt. Ltd./978-8173814051 , Analytical Geometry And Vector Algebra/Ratan Mohan Khan/New Central Book Agency Pvt. Ltd./9788-173810169 , Analytical Dynamics Of A Particle Including Elements Of Statics/Shambhunath Ganguly/New Central Book Agency Pvt. Ltd./9788-173811630 , Differential Equations With Introduction To Laplace Transform/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173816635 , Numerical Methods Practical/Shyamapada Dutta/New Central Book Agency Pvt. Ltd./978-8173815645 , A First Course On Operations Research And Information Theory/Sanat Kumar Mazumder/New Central Book Agency Pvt. Ltd./978-8173818844 , Advanced Business Mathematics And Statistics/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173816741 , Engineering Mathematics/Rajkumar Roychoudhury/New Central Book Agency Pvt. Ltd./978-8173810909 , Analytical Dynamics Of A Particle/Sambhunath Ganguly/New Central Book Agency Pvt. Ltd./978-8173810497 , Integral Calculus/Kantish Ch Maity/New Central Book Agency Pvt. Ltd./97-88173817328 , Introduction To Number Theory/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97881-73815867 , Mathematics And Statistics/Suranjan Saha/New Central Book Agency Pvt. Ltd./97881-73811838 , Mathematical Probability/Kartick Chandra Pal/New Central Book Agency Pvt. Ltd./978-8173817816 , Differential Geometry/Fr F Goreux/New Central Book Agency Pvt. Ltd./978-8173815669 , Introduction To Tensor Calculus/Fr F Goreux/New Central Book Agency Pvt. Ltd./9788-173818516 , Vector Analysis Tensor Analysis And Linear Vector Space/S P Kuila/New Central Book Agency Pvt. Ltd./9789-352550333 , Introduction To Discrete Mathematics/M K Sen/New Central Book Agency Pvt. Ltd./97881-87134886 , Topics In Mathematics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134466 , Advanced Linear Programming & Game/A Mukherjee/New Central Book Agency Pvt. Ltd./97893-84294083 , Application Of Calculus/Debasish Sengupta/New Central Book Agency Pvt. Ltd./97881-87134626 , Analytical Statics/S A Mollah/New Central Book Agency Pvt. Ltd./97893-84294427 , Basic Concepts Of Numerical Methods, Probability And Statistics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134947 , Numerical Analysis And Computational Procedures/S A Mollah/New Central Book Agency Pvt. Ltd./97881-87134107 , An Introduction To Probability And Probability Distributions/Rajeshwar Singh/New Central Book Agency Pvt. Ltd./978938-4294175 , Dynamics Of Rigid Bodies/S A Mollah/New Central Book Agency Pvt. Ltd./978818-7134985 , Differential Geometry/M Majumdar/New Central Book Agency Pvt. Ltd./978938-4294144 , Advanced Higher Algebra/A N Das/New Central Book Agency Pvt. Ltd./978938-4294021 , Introduction To Abstract And Linear Algebra/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97893-52550586 , Design Of Experiments And Sampling Methods/K C Bhuyan/New Central Book Agency Pvt. Ltd./97893-52550234 , Engineering Mathematics/T Veerarajan/Mcgraw Hill Education/ 97-0071328777 , Engineering Mathematics Ii/T Veerarajan/Mcgraw Hill Education/978-9387432345 , Advanced Engineering Mathematics/Ravish R. Singh/Mcgraw Hill Education/97-89353161033 , Discrete Mathematics/T Veerarajan/Mcgraw Hill Education/978-9353161606 , Business Mathematics And Statistics/N G Das, J. K. Das/Mcgraw Hill Education/978-0071333399 , A First Course In Mathematics For Management/M. Raghavachari/Mcgraw Hill Education/978-0070965706 , Fundamentals Of Mathematical Analysis/G. Das, S. Pattanayak/Mcgraw Hill Education/978-0074515730 , Introduction To Linear Algebra With Applications/James Defranza, Daniel Gagliardi/Mcgraw Hill Education/978-1259025587 , Numerical Methods With Programs In C/T Veerarajan, T Ramachandran/Mcgraw Hill Education/978-0070601611 , Ordinary And Partial Differential Equations With Laplace Transforms, Fourier Series And Applications/V. Sundarapandian/Khanna Publishers/978-1259004568 , Higher Engineering Mathematics/B.S. Grewal/Khanna Publishers/978-81-933284-9-1 , Discrete Mathematics And Its Applications/A. Tamilarasi And A.M. Natarajan/Khanna Publishers/978-81-7409-151-2 , Functions Of Complex Variables/A.K. Mukhopadhyay/Khanna Publishers/N/A , Numerical Methods In Engineering & Science With Programs In C, C++ & Matlab/B.S. Grewal/Khanna Publishers/978-81-7409-248-9 , An Introduction To The Calculus Of Variation For Engineers And Economics/A.K. Mukhopadhyay/Khanna Publishers/978-81-7409-186-4 , Engineering Mathematics/Mukul Bhatt/Mcgraw Hill Education India Pvt. Ltd/9789390000000 , Convective Heat And Mass Transfer/Adrian Bejan/John Wiley And Sons/978-0-470-90037-6 , Perspective In Environmental Studies/Anubha Kaushik And C P Kaushik/New Age International Publishers/978-93-86418-63-0 , Engineering Mechanics (Statics And Dynamics)/Dr D S Kumar/S K Karatia And Sons/978-93-5014-292-9 , Fundamentals Of Acoustics/Lawrence E. Kinsler, Austin R. Frey, Alan B. Coppens, James V. Sanders/Wiley/978-0-471-84789-2 , Foundations Of Engineering Acoustics/Frank Fahy/Academic Press/Elsevier/978-0122476655 , The Theory Of Sound, Volume I/Lord Rayleigh & Robert B. Lindsay/Dover Publications Inc./978-0486602929 , Mechanical Vibration/S.S. Rao/Pearson Education India/978-8177588743 , Vector Mechanics For Engineers: Statics And Dynamics/Beer, Johnston, Cornw Ell& Sanghi/Mcgraw Hill Education/978-1259062919 , Entrepreneurship Development And Small Business Enterprises/Charantimath Poornima M./Pearson/9353066263 , Entrepreneurial Development/Khanka S.S./S Chand/8121918014 , Mechanical Vibrations/Debabrata Nag/Wiley/978-8126530908 , Design Of Machine Elements/Dr.G.K.Vijayaraghav An&Dr.S.Vishnupriyan/Laxmi Publications/8192048535 , Introduction To Dynamics/Amitabha Ghosh/Springer/978-981-10-6094-6 , Mechanics Of Laminated Composite Plates And Shells – Theory And Analysis/J.N. Reddy/Crc Press/978-0203502808 , Composites: Science And Technology/Dr. R. C. Prasad, Dr. P. Ramakrishnan/New Age International (P) Ltd., Publishers/978-8122412512 , Product Design And Development/Karl Ulrich, Steven Eppinger And Maria C. Yang/Mc Graw Hill/978-1260043655 , Mechatronics: Integrated Mechanical Electronic Systems/K.P. Ramachandran, G.K. Vijayaraghavan, M.S.Balasundaram/Wiley India/978-8126518371 , Groovers Principles Of Modern Manufacturing Si Version/Mikell P. Groover/Wiley India/978-8126573059 , Manufacturing Science : Metal Cutting, Conventional And Non-Conventional Machine, Welding, Volume - Ii/G.S. Sawhney/Wiley India/97-89389520408 , Project Planning And Control With Pert And Cpm/Dr. B.C. Punmia, K.K. Khandelwal/Laxmi Publications (P) Ltd/978-8131806982 , Cad/Cam Theory And Practice/Ibrahim Zeid, R Sivasubramanian/Mcgraw Hill Education/978-0070151345 , Optimization For Engineering Design/Kalyanmoy Deb/Prentice Hall India Learning Private Limited/978-8120346789 , Mechanical Vibrations /G Kgrover/Nem Chand And Brothers /978-81-85240-56-5 , Tribology: Friction And Wear Of Engineering Materials /Ian Hutchings And Philip Shipway/Elsevier/978-0-08-100910-9 , Business Statistics: Text And Problems - With Introduction To Business Analytics/Nd Vohra/?Mcgraw Hill Education /978-9390727063 , Statistics For Management/Richard I. Levin, Masood H. Siddiqui, David S. Rubin, Sanjay Rastogi, /?Pearson Education/978-8184957495 , Financial Accounting/Sn Maheshwari, Suneel K Maheshwari,Sharad K Maheswari/?Vikas Publishing House/978-9352718535 , Management Accounting Principles & Practice/Shashi K. Gupta , R.K. Sharma, Neeti Gupta /Kalyani Publishers/N/A , Organizational Behaviour /Stephen P. Robbins, Timothy A. Judge , Neharika Vohra/?Pearson Education/978-9356064270 , Organisational Behaviour: Text, Cases & Games/K. Aswathappa/Himalaya Publishing House/978-93-5693-187-9 , Modern Microeconomics /A. Koustsoyiannis/?Palgrave Macmillan;/978-0333253496 , Business Law /Nd Kapoor /?Sultan Chand And Sons /978-9389174106 , Marketing Management /Phillip Kotler /?Pearson Education/978-9356062665 , Dominic Salvatore International Economics /Chandan Sharma /Wiley /978- 9354247170 , International Business /Charles W .L .Hill/?Mcgraw Hill/978-9355324771 , Strategic Management ( Concept & Cases )/Fred R David , Forest R David/Pearson Education/978-9332548930 , Production And Operations Management/Sn Chary/Mcgraw Hill/978-9353164812 , Production And Operations Management/E Anil Kumar , N Suresh/New Age International/978-8122421774 , E Commerce /Kenneth C. Laudon , Carol Guercio Traver/?Pearson Education/978-9356060647 , Entrepreneurship /Arya Kumar/Pearson Education /978-8131765784 , Corporate Finance /Ross , Westerfield ,Jaffe , Jordan /Mcgraw Hill /978-9390727926 , Security Analysis And Portfolio Management /Donald E. Fisher, Ronald J. Jordan, A.K . Pradhan /Pearson Education /978-9353066284 , Investment Analysis And Portfolio Management |/Prasanna Chandra /Mcgraw Hill /978-9354600074 , Advertising And Sales Promotion/Shh Kazmi, Satish Batra/Excel Books/978-8174466396 , Advertising And Sales Promotion ( An Integrated Marketing Communications Perspective)/George E Belch, , Michael A Belch, Keyoor Purani/Mcgraw Hill /978-9354600807 , Strategic Brand Management/Kevin Lane Keller , Vanitha Swaminathan, Ambi Mg Parameswaran , Issac C Jacob /Pearson Education /978-9353946135 , Human Resource Management: Text And Cases/ K. Aswathappa , Sadhna Dash/Mcgraw Hill /978-9355323675 , Managerial Economics And Business Strategy/Micheal R. Baye , Jeffery T . Prince/Mcgraw Hill/978-9354600203 , Intellectual Property Law/Avtar Singh/Eastern Book Company/978-9350289853 , Law Relating To Intellectual Property Rights/V K Ahuja/Lexis Nexis/978-8131251652 , Intellectual Property Rights Manual/Sumeet Malik/Eastern Book Company/978-9351452300 , Law Relating To Intellectual Property/Dr. B.L. Wadehra/Universal Law Publishing/978-9350350300 , Consumer Behavior/Kumar Leon G., Schiffman;Joe, Wisenblit;S. Ramesh/Pearson Education/978-9353069834 , Purchasing And Inventory Control/K S Menon And Sarita Kulkarni/ Shroff Publishers/978-8184047066 , Production Systems: Planning, Analysis, And Control/James L. Riggs /? John Wiley & Sons/? 978-0471847939 , A Textbook Ofmanufacturing Technology (Manufacturing Processes)/R K Rajput/ Laxmi Publications/? 978-8131802441 , A Textbook Of Material Science And Metallurgy /O P Khanna/Dhanpat Rai /978-8189928315 , Atomic Physics/Max Born (Author) , J. M. Radcliffe (Translated) R. J. B-. Stoyle (Translated)/Dover Publications/978-0486659848 , Concepts Of Atomic Physics/S P Kuila /New Central Book Agency (Ncba)/978-9352550838 , Fundamentals Of Molecular Spectroscopy/Banwell/Mcgraw Hill Education/978-9352601738 , Introduction To Nuclear And Particle Physics/V.K. Mittal, R.C. Verma, S.C. Gupta /Phi Learning/978-9387472617 , Concepts Ofnuclear Physics/Bernard Cohen/Mcgraw Hill Education/978-0070992498 , Nuclear And Particle Physics: An Introduction/B.R. Martin/Wiley/978-8126565078 , Introduction To Elementary Particle Physics/Alessandro Bettini/Cambridge University Press/978-1107050402 , Solid State Physics/Ashcroft, Mermin/Cengage Learning/978-8131500521 , Physics Of Semiconductor Devices/S.M. Sze, Kwok K. Ng /Wiley/978-8126517022 , Semiconductor Physics And Devices (Sie)/Donald Neamen (Author), Dhrubes Biswas/Mcgraw Hill Education/978-0071070102 , Liquid Crystal Sensors/Albert Schenning (Editor), Gregory P. Crawford (Editor), Dirk J. Broer (Editor)/Crc Press/978-1498729727 , Liquid Crystals: Experimental Study Of Physical Properties And Phase Transitions/Satyendra Kumar/Cambridge University Press/978-0521187947 , Liquid Crystals I/M.A. Athanassopoulou, M.A. Bates, Et Al./Springer/978-3662147160 , Dielectric Effect In The Isotropic Phase Of Liquid Crystal Materials/Mukherjee Prabir,Drozd-Rzoska Aleksandra,Rzoska Sylwester/Lambert Academic Publishing,/9783660000000 , Nanoscience With Liquid Crystals: From Self-Organized Nanostructures To Application/Quan Li/Springer/978-3319377124 , Fundamentals Of Mathematical Physics/A. B. Gupta/Books & Allied (P) Ltd/81-87134-23-2 , Higher Mathematical Physics/H. K. Das And Dr Rama Verma/S. Chand & Company Pvt. Ltd/978-93-83746-77-4 , Head Thermodynamics And Statistical Physics/Brij Lal, N. Subrahmanyam And P. S. Hemne/S. Chand & Company Pvt. Ltd/81-219-2813-3 , The Physics Of Solar Cells : Perovskites, Organics, And Photovoltaic Fundamentals/Juan Bisquert/Crc Press/9781138099968 , Nanomaterials And Nanocomposites: Synthesis, Properties, Characterization Techniques, And Applications/Rajendra Kumar Goyal/Crc Press/9781498761666 , Callisters Materials Science And Engineering./Balasubramaniam/Wiley India/9788126541607 , Introduction To Physics /Cutnell/Wiley India/9788126556021 , Physics, Vol 1, 5Ed , An Indian Adaptation /Halliday/Wiley India/9789354640384 , Physics, Vol 2, 5Ed, An Indian Adaptation /Halliday/Wiley India/9789354640438 , Principles Of Physics, 10Ed/Halliday/Wiley India/9788126552566 , Statistical Mechanics, 2Ed, An Indian Adaptation/Huang/Wiley India/9789354247736 , Classical Electrodynamics, An Indian Adaptation /Jackson/Wiley India/9789388991070 , Kittels Introduction To Solid State Physics, Wiley India Edition/Kittel/Wiley India/9788126578436 , Modern Physics, 4Ed, An Indian Adaptation /Krane/Wiley India/9789354244681 , Material Science: Nanotechnology And Applications /Kumar/Wiley India/9789390455317 , Introduction To Nanoscience And Nanotechnology, An Indian Adaptation /Poole/Wiley India/9789354240201 , Applied Solid State Physics/Rajnikant/Wiley India/9789354643309 , A Textbook Of Astronomy And Astrophysics /Sharma/Wiley India/9789389520903 , Tensors: Concepts And Applications With Scilab Programs/Soni /Wiley India/9789389633207 , Engineering Physics, As Per Aicte /Wiley Editorial Team/Wiley India/9788126521418 , A Textbook Of Applied Physics, Vol I/Jha/Wiley India/9789389307405 , A Textbook Of Applied Physics, Vol Ii/Jha/Wiley India/9789389520453 , Mathematical Methods In The Physical Sciences, 3Ed, An Indian Adaptation /Boas/Wiley India/9789354644252 , Fundamentals Of Fluid Mechanics/Sawhney/Wiley India/9789389698008 , Quantum Mechanics Concepts And Applications/Nouredine Zettili/Wiley India/978-0-470-02678-6 , Introductory Nuclear Physics/S. Krane Kenneth/Wiley India/978-8126517855 , Principles And Applications Of Ferroelectrics And Related Materials/M. E. Lines And A. M. Glass/Oxford University Press/978-0198507789 , A Modern Introduction To Quantum Field Theory/Michele Maggiore/Oxford University Press/978-0198520740 , The Physics Of Solids/J. B. Ketterson/Oxford University Press/978-0198742906 , Introduction To Spintronics/Supriyo Bandyopadhyay/Routledge/978-0367656447 , Perovskite Metal Oxide/Moharana/Elsevier/9780320000000 , Materials Characterization Techniques/Lin Li, Sam Zhang,Ashok Kumar/Crc Press/?978-1032064208 , Magnetic Measurement Techniques For Materials Characterization/Victorino Franco/Springer/978-3030704452 , Indentation Techniques In Ceramic Materials Characterization: Theory And Practice/Ahmad G.Solomah/Ceramics Transaction/978-1574982121 , Element Of X-Ray Diffraction/B D Cullity/Pearson Education India/9789332535169 , Introduction To Magnetic Materials/B D Cullity/Wiley-Ieee Press/978-0471477419 , Symmetry And Spectroscopy: An Introduction To Vibrational And Electronic Spectroscopy/Daniel C Harris/Dover Pubns/978-0486661445 , The Spectra And Structures Of Simple Free Radicals: Introduction To Molecular Spectroscopy/Gerhard Herzberg/Dover Pubns/978-0486658216 , An Introduction To Practical Infra-Red Spectroscopy/A D Cross/Dover Pubns/978-1489962744 , Handbook On The Physics And Chemistry Of Rare Earths: Optical Spectroscopy/Karl A.Gschneidner/North-Holland/978-0444521446 , Molecular Spectroscopy/Jackd.Graybeal/Mcgraw-Hill Education(Ise Edition)/978-0070243910 , Fundamentals Of Statistical And Thermal Physics/Frederick Reif/Sarat Book Distributors/9789380663142 , Thermodynamics And An Introduction To Thermostatistics/H. B. Callen/John Wiley & Sons Inc/9780471862567 , Introduction To Phase Transitions And Critical Phenomenon (International Series Of Monographs On Physics)/H. E. Stanley/Oxford University Press/9780195053166 , A Guide To Monte Carlo Simulations In Statistical Physics/David P. Landau And Kurt Binder/? Cambridge University Press;/9781139696463 , Statistical Mechanics/R. K. Pathria/Elsevier/9789351073970 , Computational Methods In Physics And Engineering/Samuel S M Wong/World Scientific/9810230435 , Mathematical Methods Of Physics/Jon Mathews And Robert L. Walker/?Pearson Addison-Wesley/805370021 , A Text Book Of Integrated Engineering Physics /Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-81-906486-1-5 , A Text Book Of Basic Engineering Physics/Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-8190648615
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
35.
Rural Development #9364588 Technical Bid
Tender For Purchase Of Library Books At Various Iti S Under Scdd - BASIC ELECTRONICS Auther-BERNAD GROB 3 BASIC ELECTRONICS Auther-SANJAY SHARMA 4 BASIC ELECTRONICS-PRINCIPLES AND APPLICATION Auther-CHINMONY SAHA,ARINDAM HALDER,DEBARATI GANGULY 5 BASIC ELECTRONICSAND LINEARCIRCUITS Auther-N N BHARGAVA 6 BASIC ELECTRONICS DEVICES AND CIRCUITS Auther-MAHESH B PATTIL 7 BASIC ELECTRONICS (SOLID STATE) Auther-B LTHEREJA 8 ELECTRONICS DEVICES AND CIRCUITS Auther-MILLMAN 9 ELECTRONIC DEVICES AND CIRCUITS Auther-J B GUPTHA 10 A TEXT BOOK OF ELECTRONIc CIRCUITS Auther-SEDHA R S 11 FUNDAMENTALSOF ELECTRONIC CIRCUITS Auther-CHARIES K ,ALEXANDER,MATHEW N O, SADIKKU 12 SOLID STATE ELECTRONIC DEVICES Auther-BEN G STREETMAN 13 SOLID STATE DEVICES AND TECHNOLOGY Auther-V SURESH BABU 14 PHYSICS OF SEMICONDUCTOR DEVICES Auther-S M SZE 15 BASIC ELECTRICAL ENGG Auther-M L ANWANI 16 A TEXT BOOK OF ELECTRICAL TECHNOLOGY VOLUME I Auther-B L THEREJA,A K THEREJA 17 A TEXT BOOK OF ELECTRICAL TECHNOLOGY VOLUME II(AC & DC MACHINE Auther-B L THEREJA,A K THEREJA 18 FUNDAMENTALS OF ELECTRICAL ENGINEERING AND ELECTRONICS Auther-S CHAND 19 CONSUMER ELECTRONICS Auther-S P BALI 20 INDUSTRIAL ELECTRONICS AND CONTROL Auther-S K BHATTACHARYA,B CHATTERJEE 21 POWER ELECTRONICS Auther-Dr.P S BIMBHRA 22 POWER ELECTRONICS- DEVICES AND CIRCUITS Auther-V JAGANNATHAN 23 MODERN ELECTRONIC INSTRUMENTATION & MEASUREMENT TECHNIQUES Auther-ALBERT D HELFRICK,WILLIAM D COOPER 24 PRINCIPLES OF ELECTRONIC DEVICES AND CIRCUITS (ANALOG AND DIGITAL) Auther-S CHAND,BL THEREJA,Dr.R S SEDHA 25 DIGITAL FUNDAMENTALS Auther-THOMAS S FLOID 26 FUNDAMENTALS OF DIGITAL CIRCUITS Auther-A ANAND KUMAR 27 DIGITAL CIRCUITS AND DESIGN Auther-S SALIVAHANAN,S ARIVAZHAGAN 28 MODERN DIGITAL ELECTRONICS Auther-R P JAIN 29 COMMUNICATION SYSTEM (ANALOG AND DIGITAL) Auther-Dr. SANJAY SHARMA 30 WIRELESS COMMUNICATION :PRINCIPLES AND PRACTICE Auther-RAPPAPORT 31 MOBILE COMMUNICATION Auther-JOCHEN SCHILLER 32 THE CELLPHONE:THE HISTORY & TECHNOLOGY OF THE GADGET THAT CHANGED THE WORLD Auther-GUY KLEMENS 33 SOLAR PHOTO VOLTAIC POWER SYSTEMS: PRINCIPLES, DESIGN AND APPLICATION Auther-Dr.SUNDARAVADIVELU,SURESH R NORMAN 34 SOLAR PHOTOVOLTAIC TECHNOLOGYAND SYSTEMS- (FUNDAMENTALS,TECHNOLOGY AND APPLICATIONS)Auther-CHETAN SINGH SOLANKI 35 ELECTRONIC COMMUNICATION SYSTEMSAuther-GEORGE KENNEDY,BERNAD DAVIS, S R M PRESANNA 36 MONOCHROME AND COLOUR TELEVISION Auther-R R GULATHI 37 MICROPROCESSORS AND MICROCONTROLLERS Auther-A NAGOOR KANI 38 THE 8051 MICROPROCESSORS AND EMBEDDED SYSTEM Auther-MAZIDI 39 MICROPROCESSORARCHITECTURE PROGRAMMING AND APPLICATIONS WITH THE 8085 Auther-REMESH S GOANKAR 40 THE 8085 MICROPROCESSORARCHITECTURE, PROGRAMMING AND INTERFACING Auther-UDAY KUMAR,UMA SHANKER 41 MICROPROCESSOR AND MICROCONTROLLER (8085,8086,8051- ARCHITECTURE,INTERFACING AND PROGRAMMING) Auther-A P GODSE, D A GODSE 42 8051 MICROCONTROLLER ARCHITECTURE,PROGRAMMING AND APPLICATION Auther-M MAHALAKSHMI 43 THE THE 8051MICROCONTROLLER 8051- ARCHITECTURE, PROGRAMMING,AND APPLICATIONS Auther-KENNETH J AYALA 44 PROGRAMMING ARDUINO :GETTING STARTED WITH SKETCHES Auther-SIMON MONK 45 ARDUINO PROGRAMMING STEP BY STEP GUIDE MASTER ARDUINO HARDWARE AND SOFTWARE Auther-MARK TORVALDS 46 PRINTED CIRCUIT BOARDS(DESIGN,FABRICATION,,ASSEMBLY AND TESTING Auther-R S KHANDPUR 47 FUNDAMENTALS OF COMPUTERS Auther-E BALAGURUSWAMI 48 MODERN COMPUTER HARDWARE COURSE Auther-MANAHAR LOTIA, PRADEEP NAIR,PAYAL LOTIA 49 ELECTRONICS LAB MANUAL VOL-I Auther-K A NAVAS 50 ELECTRONICS LAB MANUAL VOL-II Auther-K A NAVAS 51 OBJECTIVE ELECTRONICSENGINEERING Auther-ARIHANT PUBLICATIONS 52 QUESTION BANK IN ELECTRONICS AND COMMUNICATION ENGINEERINGAuther-J B GUPTHA 53 OBJECTIVE ELECTRICAL, ELECTRONICS AND COMMUNICATION ENGINEERING Auther-B L THEREJA, Er. V K PANDEY 54 P S C-PREVIOUS QUESTIONS AND ANSWERS IN ELECTRICAL/ELECTRONICS ENGINEERING Auther-ELECTRON COLLEGE OF TECHNOLOGY 55 ELECTRONIC MECHANIC TRADE THEORY FORANNUAL AITT EXAMS Auther-A K MITTAL 56 ABC OFELECTRICALENGG Auther - B L THEREJA & A K THERAJA 57 BASICS OF ELECTRICAL ENGG Auther - MEHTA AND GUPTHA 58 BASIC ELECTRICAL ENGG Auther - S K BHATTACHARYA 59 PRINCIPLES OF ELECTRICAL ENGG & ELECTRONICS Auther - V K MEHTA & ROHIT METHA 60 ELECTRIC CIRCUIT ANALYSIS Auther - K S SURESH KUMAR 61 BASICS OF ELECTRICAL ENGG Auther - BABUJAN 62 BASIC ELECTRICAL AND INSTRUMENTATIONENGG Auther - J GNANAVADIVEL 63 FUNDAMENTALS OF ELECTRICITY AND MAGNETISM Auther - S K CHATTERJEE 64 A TEXT BOOK OF ELECTRICAL TECHNOLOGY VOLUME I Auther - B L THEREJA,A K THEREJA 65 A TEXT BOOK OF ELECTRICAL TECHNOLOGY VOLUME II(AC & DC MACHINE Auther - B L THEREJA,A K THEREJA 66 A TEXT BOOK OF ELECTRICAL TECHNOLOGY VOLUME III Auther - B L THEREJA, A K THEREJA 67 PRINCIPLES OF POWER SYSTEM Auther - V K METHA 68 FUNDAMENTALS OF ELECTRICAL ENGINEERING AND ELECTRONICS Auther - BL THEREJA 69 BASIC ELECTRONICS AND LINEAR CIRCUITS Auther - N N BHARGAVA 70 FUNDAMENTALS OF DIGITAL CIRCUITS Auther - A ANAND KUMAR 71 DIGITAL CIRCUITS AND DESIGN Auther - S SALIVAHANAN,S ARIVAZHAGAN 72 BASIC ELECTRONICS(SOLID STATE) Auther - B L THEREJA 73 ELECTRONIC DEVICES AND CIRCUITS Auther - J B GUPTHA 74 ELECTRICAL ENGINEERING OBJECTIVE TYPE Auther - M HANDA & A HANDA 75 OBJECTIVEELECTRICALENGINEERING Auther - G K MITHAL 76 ELECTRICAL MACHINE DRAWING Auther - S K BHATTACHARYA 77 INDUSTRIAL ELECTRONICS AND CONTROL Auther - S K BHATTACHARYA 78 GENERATION DISTRIBUTION & UTILISATION OF ELECTRICAL ENERGY Auther - C L WADHWA 79 THE PERFOMANCE AND DESIGN OF A C MACHINES Auther - M G SAY 80 A COURSE IN ELECTRICAL POWER Auther - J B GUPTHA 81 ELECTRICAL CIRCUIT THEORYAuther - DR D CHATTOPADHYAY 82 LAB MANUALS FOR ELECTRICALMACHINES Auther - D P KOTHARI 83 SWITCH GEAR PROTECTION Auther - J B GUPTHA 84 ELECTRONICS LAB MANUAL VOL-I Auther - K A NAVAS 85 ELECTRONICS LAB MANUAL VOL-II Auther - K A NAVAS 86 OBJECTIVEELECTRICAL & ELECONICS ENGINEERING Auther - B L THERAJA AND V K PANDEY 87 ELECTRIC POWER TRANSMISSION & DISTRIBUTION Auther - J B GUPTHA 88 P S C-PREVIOUS QUESTIONS AND ANSWERS IN ELECTRICAL/ELECTRONICS ENGINEERING Auther - ELECTRON COLLEGE OF TECHNOLOGY 89 FUNDAMENTALS OF ELECTRICITY AND MAGNETISM Auther - S K CHATTERJEE 90 FUNDAMENTALS OF COMPUTERS Auther - E BALAGURUSWAMI 91 BASIC ELECTRICAL ENGG Auther - ANWANI 92 PRINCIPLES OF ELECTRONICS Auther - V K MEHTA 93 QUESTION BANK FOR ELECTRICIAN Auther - ASIAN PUBLICATIONS 94 ELECTRICAL MEASURMENTS AND MEASURING INSTRUMENTS Auther - Er. R K RAJPUT 95 ELECTRICAL AND ELECTRONICS MEASURMENTS AND INSTRUMENTATION Auther - Er. R K RAJPUT 96 HANDBOOK OF ELECTRICAL ENGINEERING Auther - S L BHATIA 97 ELECTRICAL ENGG( OBJECTIVE QUESTIONS & ANSWERS) Auther - V K METHA 98 ELECTRICAL SUBSTATIONAuther - S RAO 99 ELECTRICAL WIRING ESTIMATING & COSTING Auther - S L UPPAL 100 Basic Shop TheoryCarpentryAuther -(R.C.GUPTA) Danpath rai publication 101 A text bookof Work shoptechnology Vol .I&II Auther - R.S.KHURMI&J.K.GUPTA 102 Carpentrya complete guide Auther - H.S.BAWA 103 The complete visual guide to building a house Auther -John Carrol 104 House buildingDIY Guide Auther - William Null 105 Carpentry And construction Auther - Rex Miller 106 How your house works Auther -Chales Miller 107 Timber Frame Auther - Eugine Walls 108 Dewalt- carpentry and framing Auther - Dewalt 109 Complete book offraming Auther - Wiley 110 BUILDING MATERIALS Auther - P.C VARGHEESE 111 BUILDING MATERIALS Auther - RANGWALA 112 BUILDING MATERIALS Auther - RAJPUTH 113 BUILDING MATERIALS Auther - S.K.DUGGAL 114 BUILDING MATERIALS Auther - N SUBRAMANIAN 115 SURVEYING Auther - R.SUBRAMANIAN 116 SURVEYING AND LEVELLING Auther - N.N BASAK 117 SURVEYING AND LEVELLING Auther - PUNMIA 118 ENGINEERING SURVEY Auther - SCHOFIELD 119 SURVEYING - Auther - S.K HUSAIN, M.S NAGARAJ 120 BUILDING CONSTRUCTION Auther - PUNMIA 121 BUILDING CONSTRUCTION Auther - RANGWALA 122 BUILDING CONSTRUCTION Auther - S.CHAND 123 BUILDING CONSTRUCTION Auther - S.K.DUGGAL 124 BUILDING CONSTRUCTION Auther - S.P ARORA 125 ESTIMATION AND COSTING IN CIVIL ENGINEERING Auther - B.N.DUTTA 126 CIVIL ESTIMATING AND COSTING Auther - A K UPADHYAY 127 ESTIMATION AND COSTING IN CIVIL ENGINEERINGTHEORY AND PRACTICE Auther - B.N.DUTTA 128 ESTIMATING AND COSTING Auther - D.D.KOHLI 129 FUNDAMENTALS OF CONSTRUCTION ESTIMATING Auther - DAVID PRATT 130 RAILWAY ENGINEERING Auther - S.C.SEXENA 131 HIGHWAY ENGINEERING Auther - S.K.KHANNA 132 TRAFFIC ENGINEERING & TRANSPORTATION PLANNING Auther - L.R.KADIYALI 133 PRINCIPLES OF TRANSPORTATION ENGINEERING Auther - G.V.RAO 134 RAILWAY TRACK ENGINEERING Auther - J.S.MUNDREY 135 IRRIGATION ENGINEERING & HYDRAULIC STRUCTURE Auther - S.K.GARG 136 IRRIGATION & WATER POWER ENGINEERING Auther - B.C.PUNMIA 137 IRRIGATION,WATER POWER AND WATER RESOURCE ENGINEERING Auther - K.R.ARORA 138 IRRIGATION ENGINEERINGAuther - S R SAHASRABUDHE 139 WATER SUPPLY AND SANITTARY ENGINEERING Auther - RANGWALA 140 WATER SUPPLYENGINEERING Auther - S K GARG 141 HYDROLOGY AND WATER RESOURCES Auther - S.K.GARG 142 A TEST BOOK OF ENGINEERING DRAWING Auther - K V NATARAJAN 143 A TEST BOOK OF ENGINEERING GRAPHICS Auther - P I VARGHESE 144 BUILDING PLANNING AND DRAWING Auther - Dr. N KUMARASWAMY 145 BUILDING PLANNING AND DRAWING Auther - S S BHAVAKATTI 146 CIVIL ENGINEERING CONVENTIONAL AND OBJECTIVE TYPE Auther - R S KHURMI , J K GUPTA 147 HAND BOOK OF CIVIL ENGINEERING Auther - ME EDITORIAL BOARD 148 CIVIL ENGINEERING CONVENTIONAL AND OBJECTIVE TYPE Auther - R AGOR 149 QUESTION BANK IN CIVIL ENGINEERING Auther - V S MURTHY , R SOOD 150 AUTOMOBILE ENGINEERING VOL- 1 Auther - KIRPAL SINGH 151 AUTOMOBILE ENGINEERING VOL- 2 Auther - KIRPAL SINGH 152 A TEXT BOOK OF AUTOMOBILE ENGINEERING Auther - R K RAJPUT 153 AUTOMOBILE ENGINEERING Auther - R B GUPTA 154 AUTOMOBILE ENGINEERING Auther - RAMAKRISHNA 155 AUTOMOBILE MECHANICS Auther - N K GIRI 156 AUTOMOTIVE MECHANICS Auther - CROUSE, ANGLIN 157 AUTOMOTIVE MECHANICS Auther - S SRINIVASAN 158 AUTOMOBILE ENGINEERING Auther - BABU A K 159 BASIC ENGINEERING THERMODYNAMICS Auther - JOEL 160 FITTER COURSE BOOK Auther - RANJAN , NITESH 161 BASIC AND APPLIED THERMODYNAMICS Auther - NAG 162 A TEXT BOOK OF REFRIGERATION AND AIR CONDITIONING Auther - KHURMI/GUPTA 163 ENGINEERING GRAPHICS Auther - K N ANILKUMAR 164 ATB OF BASIC MECHANICAL ENGINEERING Auther - BENJAMIN 165 ENGINEERING DRAWING (GEOMETRICAL DRAWING) Auther - GILL P S 166 HAND BOOK OF MECHANICAL ENGINEERING Auther - MEHTHA SUBASH 167 A HAND BOOK ON ELECTRONICS &COMMUNICATION ENGG: Auther - MADE EASY 168 BASIC ELECTRICAL ENGG: Auther - V K MEHTA 169 MACHINE DRAWING Auther - VARGHESE /JOHN 170 MACHINE DRAWING Auther - N D BHATT 171 FUNDAMENTALS OF ELECTRONICS ENGINEERING Auther - PRASAD RAJENDRA 172 TRUCK ENGINES – FUEL&COMPUTERISED MANAGEMENT SYSTEM Auther - BENNETT 173 AUTOMOTIVE ENGINEERING LIGHT WEIGHT, FUNCTIONAL Auther - CANTOR BRIAN 174 AUTOMOTIVE TECHNOLOGY ENGINE PERFORMANCE Auther - CARRIGAN RUSSELL 175 AUTOMOTIVE TECHNOLOGY HEATING & AIR CONDITIONING Auther - CARRIGAN RUSSELL 176 MATERIALS FOR AUTOMOBILE BODIES Auther - DAVIES GEOFF 177 DESIGN OF AUTOMATIC MACHINERY Auther - DERBY STEPHEN J 178 ELETRIC VEHICLE BATTERY SYSTEMS Auther - DHAMEJA SANDEEP 179 AUTOMOTIVE TECHNOLOGY ENGINE REPAIR Auther - DORRIES ELISABETH H 180 VEHICULAR ELETRIC POWER SYSTEM Auther - EMADI ALI 181 A SYSTEM APPROACHTO AUTOMOTIVE TECHNOLOGY Auther - ERJAVEC 182 AUTOMOTIVE TECHNOLOGY SUSPENSION & STEERING Auther - ERJAVEC JACK 183 AUTOMOTIVE ENGINEERING MANUAL TRANSMISSION VOL -1 Auther - ERJAVEC JACK 184 AUTOMOTIVE ENGINEERING MANUAL TRANSMISSION VOL -2 Auther - ERJAVEC JACK 185 ALTERNATE FUEL TECHNOLOGY – ELECRICAL-HYB-&FUEL Auther - ERJAVEC 186 AUTOMOTIVE TECHNOLOGY BRAKES Auther - ERJAVEC JACK 187 AUTOMOTIVE ENGINEERING AUTOMATIC TRANSMISSION VOL -1 Auther - ERJAVEC JACK 188 AUTOMOTIVE ENGINEERING AUTOMATIC TRANSMISSION VOL -2 Auther - ERJAVEC JACK 189 THE AUTOMOTIVE CHASSIS VOL -1 Auther - GENTA GIANCARLO 190 THE AUTOMOTIVE CHASSIS VOL -2 Auther - GENTA GIANCARLO 191 MAINTENANCE OF AUTOMOTIVE ENGINES Auther - GILLES 192 AUTOMOTIVE ENGINEERING ENGINE REPAIR AND REBUILDING VOL-1 Auther - HADFIELD CHRISTOPHER 193 AUTOMOTIVE ENGINEERING ENGINE REPAIR AND REBUILDING VOL-2 Auther - HADFIELD CHRISTOPHER 194 AN INTRODUCTION TO MODERN VEHICLE DESIGN Auther - HAPPIAN-SMITH,JULIAN 195 AUTOMOTIVE TECHNOLOGY FUELS&EMISSIONS Auther - HOLLEMBEAK BARRY 196 AUTOMOTIVE TECHNOLOGY FUELS&EMISSIONS VOL -2 Auther - HOLLEMBEAK BARRY 197 AUTOMOTIVE TECHNOLOGY SERVICE & MAINTENANCE Auther - KNOWELS DON 198 AUTOMOTIVE ENGINEERING SUSPENSION AND STEERING VOL - 1 Auther - KNOWELS DON 199 AUTOMOTIVE ENGINEERING SUSPENSION AND STEERING VOL - 2 Auther - KNOWELS DON 200 THE AUTOMOTIVE BODY VOL – 1COMPONENTS DESIGN Auther - MORELLO LORENZO 201 THE AUTOMOTIVE BODY VOL – 2 SYSTEM DESIGNAuther - MORELLO LORENZO 202 AUTOMOTIVE TECHNOLOGY SERVICE & SYSTEM Auther - OWEN CLIFTON E 203 AUTOMOTIVE ENGINEERING BRAKE SYSTEM VOL - 1 Auther - OWEM LE 204 AUTOMOTIVE ENGINEERING BRAKE SYSTEM VOL - 2 Auther - OWEM LE 205 AUTOMOTIVE ENGINEERING ENGINE PERFORMANCE VOL - 1 Auther - PICKERILL KEN 206 AUTOMOTIVE CHASSIS Auther - REIMPELL J 207 AUTOMOTIVE ENGINEERING ENGINE PERFORMANCE VOL - 2 Auther - PICKERILL KEN 208 AUTOMOTIVE ENGINEERING HEATING & AIR CONDITIONING Auther - SCHNUBEL MARK 209 WORK SHOP TECHNOLOGY VOL .1 Auther - SK HAJRA CHOUDHURY,AK HAJRA CHOUDHURY,NIRJHAR ROY 210 WORK SHOP TECHNOLOGY VOL .2 Auther - SK HAJRA CHOUDHURY,AK HAJRA CHOUDHURY,NIRJHAR ROY 211 WORK SHOP CALCULATION & SCIENCE Auther - KAPIL DEV 212 METALLURGICAL ENGINEERING (MULTI CHOICE QUESTIONS AND ANSWERS ) Auther - O P GUPTA 213 FLUID MECHANICS AND HYDRAULIC MACHINES Auther - S CHAND 214 MECHANICAL ENGINEERING (OBJECTIVE TYPE) Auther - D HANDA 215 MECHANICAL ENGINEERING FOR COMPETITIONS Auther - R K JAIN 216 MECHANICAL ENGINEERING (OBJECTIVE TYPE QUESTIONS ) Auther - S CHAND 217 MECHANICAL ENGINEERING (CONVECTIONAL AND OBJECTIVE TYPE ) Auther - R S KHURMI ,JK GUPTA 218 OBJECTIVES AUTOMOBILE ENGINEERING Auther -INDIA PUBLICATION 219 MPSC (MECHANICAL AND AUTOMOBILE ENGINEERING ) Auther - K SAGAR PUBLICATIONS 220 OBJECTIVE AUTOMOBILE ENGINEERING Auther - P K MISHRA 221 MECHANICAL ENGINEERING OBJECTIVE Auther - D S KUMAR 222 ENGINEERING MATHEMATICS Auther - KARAIYA 223 AUTOMOTIVE ELECRICAL AND ELECTRONICS Auther - A K BABU 224 AUTOMOTIVE MASTER TECHNICIAN Auther - GRAHAM STOAKES 225 HYBRID ELETRIC VEHICLES Auther - WILEY 226 ENGINE TESTING 2ED Auther - BUTTERWORTH 227 STRENGTH OF MATERIALS (3RD ED) Auther - TIMOSHENKO,STEPHEN 228 THE ILLUSTRATED AUTOCAD QUICK REFERENCE WINDOWS Auther - GRABOWSKI 229 INTERNAL COMBUSTION ENGINE Auther - MATHUR 230 MECHANICAL ENGINEERING OBJECTIVE Auther - BANSAL 231 A TEXTBOOK OF FLUID MECHANICS AND HYDRAULIC MACHINES Auther - BANSAL 232 A TEXTBOOK OF INTERNAL COMBUSTION ENGINE Auther - RAJPUT 233 THERMAL ENGINEERING Auther - RAJPUT 234 DESIGN OF MACHINE ELEMENTS Auther - BHANDARI V 235 THEORY OF LUBRICATION PB Auther - GHOSH M K 236 STRENGTH OF MATERIALS Auther - RATAN S S 237 MAGNETIC BEARING AND BEARINGLESS DRIVES Auther - CHIBA 238 ATEXTBOOK ON ENGINEERING GRAPHICS Auther - SATHEESH PAUL 239 MECHATRONICS: ELECTRONIC CONTROL SYSTEMS IN MECHANICAL AND ELECTRICAL ENGINEERING, 4E Auther - BOLTON 240 INTRODUCTION TO INDUSTRIAL ROBOTICS, 1/E Auther - RAMACHANDRAN NAGARAJAN 241 STRENGTH OF MATERIALS Auther - KHURMI R S 242 BASIC MANUFACTURING PROCESSES (WORKSHOP TECHNOLOGY) (FOR UPTU, LUCKNOW) Auther - KHURMI R.S. & GUPTA J.K. 243 APPLIED MECHANICS AND STRENGTH OF MATERIAL Auther - KHURMI R.S. 244 MATERIAL SCIENCE Auther - SEDHA R.S 245 HYDRAULICS & PNEUMATICS CONTROLS Auther - SHANMUGA SUNDRAM 246 OBJECTIVE TYPE QUESTION IN MECH ENGG Auther - SING V.P 247 MECHATRONICS & MICROPROCESSORS Auther - K.P RAMACHANDRAN 248 ELETRICAL TECHNOLOGY ( I TO IV VOL ) Auther - THERAJA 249 WORK SHOP CALCULATION AND SCIENCE Auther - MEHTA AND GUPTA 250 PLUMBING(MALAYALAM) Auther - B JAYAPALAN 251 DESIGN & PRACTICAL HANDBOOKON PLUMBING Auther - VIVEKANAND & MOHAN 252 PLUMBING DESIGN AND PRACTICE(English) Auther - Deolalikar 253 WATER SUPPLY ENGINERING Auther - SANTHOSH KUMAR GARG 254 WATER SUPPLY AND SANITARY ENGINERING Auther - RANGAWALA 255 BUILDING MATERIALS AND CONSTRUCTION Auther - Dr ANIL KUMAR MISRA 256 BUILDING CONSTRUCTION Auther - RANGAWALA 257 MECHANICAL WOEKSHOP PRACTICEAuther - K C JOHN 258 PLUMBER TRADE THEORY Auther - (ASIAN PUBLICATION) 259 Industrial safety &EnvironmentManagement System (English) Auther - R.J.Jain & Sunil.S .Rao,Khanna,Publication 260 Air pollution & Global Warranty Auther - Markz Jacobson 261 Personal Finance & Enterprenership (four book bundle) Auther - Jeff Lively, Kindle Edition 262 Free hand drawing Light and Shade, Free hand Perspective Auther - Kindle Edition 263 Practical Letter Book (Lettering, Caligraphy, Typography) Auther - J.H. Kaemmer, Kindle Edition 264 DTP Trainings Guide Auther - Sathish Jain 265 Corel Draw X 7 Official Guide Auther - Gary DavidBouton 266 Photoshop CC For Beginners Auther - Joseph Joyner 267 Notes on the Preparation of Silk Screen for use in Silk Screen Printing (English) Auther - Anon 268 Printing & Decorating Methods Auther - Franklin Classics Trade Press 269 Powder Coating Technology Hand Book Auther - Engineers India Research Institute 270 Anatomy and DrawingAuther - Victor Derard 271 Oxford Advanced Learners Dictionary with DVD Auther - Oxford University Press 272 Advanced Spoken English Auther - Madan sood 273 Basics of Computer Auther - U&S Publishers 274 BGAS CSWIP Painting Inspector Text Auther - TWI India Private Limited 275 Surveying Vol.I,17/e PB Auther - Punmia B C 276 Surveying Vol.III (Higher Surveying),15/e PB Auther - Punmia B C 277 Surveying 7/e: Theory and Practice PBAuther - Anderson J M 278 Surveying Vol.2 4/e (PB) Auther - Duggal 279 Surveying Vol.14/e (PB) Auther - Duggal S K 280 Suveying and Levelling 2/e P B Auther - Subramanian 281 Surveying & Levelling Part-2,PB Auther - KanetkarT P 282 Surveying Volume-1 (In SI Units),12/e PB Auther - Arora K R 283 Surveying Volume-3 (SI Units)PB Auther - Arora K R 284 Railway Transportation: Engineering,Operation and Management 2/e PB Auther - Ponnuswamy S 285 Railway Engineering 2/e PB Auther - Agarwal M M 286 Principles of Railway Engineering25/e PB Auther - Rangawala S C 287 Building Construction,Metric Volume-4,4/e (PB) Auther - McKay JK 288 Building Construction,Metric Volume-1,5/e (PB) Auther - McKay WB 289 Building Construction,Metric Volume-2,4/e (PB) Auther - McKay WB 290 Building Construction,Metric Volume-3,5/e (PB) Auther - McKay WB 291 Building Construction (PB) Auther - Meheta M 292 Building Construction Materials and Techniques 1/8e (PB) Auther - Purushothama R 293 Building Construction 2/e PB Auther - Varghese P C 294 Building Construction and Materials,14/e PB Auther - Singh,Guruchara 295 Building Construction PB Auther - Bhavikatti S S 296 Building Construction,33/e PB Auther - Rangawala 297 Textbook of Building Construction (Including Engineering Materials for Engineering students) Auther - Arora S P 298 Textbook of of Building Construction and Construction Materials PB Auther - Birdie G S 299 Building Construction,11/e PB Auther - Punmia B C 300 Textbook of of Building Construction (Including Engineering Materials for Engineering students) Auther - Arora S P 301 Building and Construction Materials:Testing and Quality Control (Lab Manual Series) Auther - Gambhir J 302 Building Materials: Products,Properties and Systems PB Auther - Gambhir M L 303 Concrete:Microstructure,Properties,and Materials PB Auther - Mehta 304 Strength of Materials SOS,4/e PB Auther - Nash William A 305 Building Materials andConstruction PB Auther - Sahu G C 306 Civil Engineering Materials PB Auther - Somayaji S 307 Building Materilas PBAuther - Varghese P C 308 Mechanics of Materials 2/e PB Auther - Gere J M 309 Material Characteristics (HB) Auther - Angelo 310 Mechanics of Materials 2/e PB Auther - Pytel 311 Strngth of Materials (PB) Auther - Shukla K K 312 Enginering materilas 9/e (PB) Auther - Budinski K G 313 Basic Engineering Mechanics and Strength of Materilas PB Auther - Das,Madan moha 314 Basic Civil Engineering (KTU Syllabus) PB Auther - Nalpat S 315 Basics of Civil engineering (KTU) PB Auther - Swarnalatha 316 Elements of Civil Engineering,1/e PB Auther - Saikia,Mini Da 317 Introduction to Civil Engineering PB Auther - Jayagopal S 318 Civil Engineering (Conventional& Objective Type) PB Auther - Khurmi R S 319 Estimating and Costing In Civil Engineering (Eng.Ed) : Theory and Practice 28/e PB Auther - Dutta B N 320 Estimating and Costing In Civil Engineering :Theory and Practice including Specifications and Valuations) Auther - Dutta B N 321 Fundamentals of Civil Engineering 4/e PB Auther - Thomas R M 322 Basics of Civil engineering Revised 3/e (Calicut ) PB Auther - Michael A 323 Basic Civil Engineering (KTU) PB Auther - Minu S 324 Civil Engineering (Objective Type) PB Auther - Reddy P J R 325 Estimating,Costing,Specification&Valuation in Civil Engineering(Includes Computer Estimation) Auther - Chakraborthi M 326 Construction planning,Equipments and Methods 7/e PB Auther - Peufoy,Robert 327 Building Drawingwith an Integrated Approach to Built Environment 5/e Pb Auther - Shah M G 328 Solid Waste Engineering PB Auther - Versilind 329 Highway Engineering PB Auther - Rangwala 330 Water Supply and Santary Enginnering PB Auther - Rangwala 331 Principles of Highway Engineering PB Auther - Khitoliya R K 332 Principles and Practicesof Highway Engineering (Including Expressways and Airport Enginnering) Auther - Kadyali L R 333 Professsional Construction management 3/e PB Auther - Barrie D S 334 Water and Wastewater Engineering:Desian Principles and PracticeAuther - Davis M L 335 Construction Management Fundamentals 2/e PB Auther - knuston K 336 Estimating Construction Costs 6/e (PB) Auther - peurifoy R L 337 Bridge Enginnering ,2/e HB Auther - Ponnuswamy S 338 Highway Engineering 10e PB Auther - Khanna S K 339 Traffic Engineering 4/e (PB) Auther - Roess.R P 340 Water Resourcing Engineering PB Auther - Wurbs R A 341 Watershed Management PB Auther - Das M M 342 Design of Bridge Structures,2nd Edition PB Auther - Jagadeesh T R 343 Solid and Liquid Waste Management Waste To Wealth (PB) Auther - Rajaraman V 344 Engineering inRocks for Slopes,Foundation 3/e (PB) Auther - Ramamurthy T 345 Indian Practical Civil Engineers Handbook HB Auther - Khanna P N 346 Assistant Engineering Rank fileAuther - Electron 347 Objective Civil Engineering Auther - Electron 348 Surveyor Rank File Auther - Electron 349 Psc Previous questions & Answers in Civil Engineering Auther - Electron 350 Objectives in Civil Engineering Auther - P K Nair 351 Upkars Objective Civil Engineering Auther - P K Mishra 352 A Handbook on Civil EngineeringAuther - Prof Jyoti Nag 353 Practice Sets Civil EngineeringAuther - Piyush Gupta 354 Civil Engineering objective TypeAuther - S Handa 355 Mastering Autocad (Malayalam) Auther - Info kairali 356 Autocad 2013 Auther - Vishnu P Singh 357 Autocad 2009/2010/2013 Auther - Vishnu Priya Singh 358 Cativa V5R20 for Engineering & Designers Auther - Prof Sham Tickoo 359 Design of Bridges Auther - N Krishna raju 360 A Handbook on Civil EngineeringAuther - made easy pub 361 handbook of Civil Engineering Auther - P Sheena 362 Survey (Malayalam) Auther - T V George 363 Dictionary of Technical terms Auther - F S Crispin 364 Oxford Dictonary of Surveying & Civil Engineering Auther - Christopher 365 Strength of Materials Auther - R S Khurumi 366 Strength of Materials Auther - S Ramamrutha 367 A text book Draughtsman CivilAuther - R S Malik 368 Irrigation Water Resources &water power Engineering Auther - P N Modi 369 Irrigation Water&water power Engineering Auther - Dr B C Punmia 370 Computer aided EngineeringDrawing Auther - Subrata pal 371 Engineering Drawing &Graphics using Autocad Auther - T Jeyapoovan 372 Building Design &Civil Engineering Drawing Auther - Dr Balagopal T S Prabhu 373 Irrigation & Drainage Management Auther - R N Sahay 374 Dictionary of geographical Information systems Auther - Haojam Rocky Singh 375 Remotesensing & geographic Information System Auther - A M Chandra 376 An Introduction to geographical information systems Auther - Ian Heywood 377 English English Malayalam Dictionary Auther - T Ramalingam Pillai 378 Malayalam Malayalam English Dictionary Auther - Dr B C Balakrishnan 379 English English Malayalam Dictionary Auther - Prof A P Namboodiri 380 Malayalam English Dictionary Auther - DC Books 381 English English Malayalam DictionaryMalayalam Dictionary Auther - Star Books 382 Surveyor (NSQF-5 Annual Syll.)TH.& Asst/Test (SOL) 1ST and 2nd Year Auther - G S Sethi 383 W/Shop cal& Sc (D manCivil & Surv) (NSQF-5 Syll) Nimi-DGET Auther - Kapil Dev,Murthy 384 EmployabilitySkills (NSQF Annual Syll) for all Trades) Auther - Asian coreTeam 385 Man Civil TH & Pract (With Sol.Asst) (NSQF-5 Syll) Sem 1& 2 Auther - Malik & Meo 386 D-Man Civil Th & Pract (With Sol Asst) (NSQF-5 Syll)Sem 3 & 1 Auther - Singh & Singh 387 Engg.Drg Common for All (NSQF Levl-4/5) Auther - Kapil Dev 388 Q-Bank Employability Skills (MCQ & Upto date SOL Paper) NSQF-4/5) Auther - Nagaradjane 389 Employability Skills (NSQF-Annual Syll.)(For All, Trades) Auther - Asian Core Team 390 Books Land Surveyor Auther - Cambridge 391 Advanced Surveying Auther - Satheesh Gopi,Sathikumar 392 Fundamentals of Surveying Auther - S K Roy 393 Building MaterialAuther - S K Duggal 394 Surveying Auther - Kumar 395 Surveying Vol-1 Auther - S K Duggal 396 Surveyor rank File Auther - Electron Publication 397 Civil Previous Question paper Auther - Electron Publication 398 Remote Sensing & Environment Auther - John R Johnsen 399 Remote Sensing & GIS Auther - Basuded Bhatta 400 Basics of Remote Sensing & GIS Auther - Dr.S Kumar 401 Advanced Surveying Auther - Gopi Sathessh 402 GIS Fundamntal Application and Implemantation Auther - K Elangovan Elangovan 403 Text book of remote Sensing and Geographical Information Sysytem Auther - M Anji Reddy 404 A Dictionary of Construction, Surveying, and Civil Engineering (Oxford Quick Reference) Auther - Oxford 405 WELDING ENGINEERING AND TECHNOLOGY Auther - RS PARMER 406 WELDINGTECHNOLOGY AND DESIGN Auther - V RADHAKRISHNAN 407 WELDING PRINCIPLE AND PRACTICE Auther - EDWARD R BOHNART 408 WELDING ANSWER : OBJECTIVE QUESTION AND ANSWER Auther - MANOJ DOLE 409 MANUFACTURING TECHNOLOGY : FOUNDRY, FORMING & WELDING Auther - Dr. P N RAO 410 BUILDING METALLURGY AND WELDABILITY OF STAINLESS STEEL Auther - JOHN C LIPPORD 7 DAMIAN J KOTTECKI 411 NEW DEVELOPMENTS IN ADVANCE WELDINGAuther - NAHMED 412 MODERN ARC WELDING TECHNOLOGY Auther - NADKARNI SV 413 WELDING SCIENCE AND METTULARGY AND TECHNOLOGY Auther - AAMERSH BANERGEE 414 A PRACTICAL MANUAL OF AUTOGENOUS WELDING Auther - E GRANJON 415 A TEXT BOOK ON WELDING AND CUTTING METALS BY THE OXYACETYLEN PROCESS STEAL METTULARGY Auther - VULCAN PROCESS CO 416 WELDING HAND BOOK 9 TH EDITION VOL-1 Auther - AWS 417 WELDING SKILLS PROCESS AND PRACTICE FOR ENTRY LEVEL WELDERS Auther - LARRY F JUFFERS AND LAWRENCE BOWER 418 ARC WELDING OLD TIME METHOD OF METAL WORKING Auther - TONY SALVITTI 419 FABRICATION AND WELDING ENGINEERING Auther - TIMINGS 420 WELDING TECHNOLOGY Auther - GUPTA 421 MIG WELDING GUID Auther - KLAS WEMAN 7 G LINDEN 422 Automobile Engineering VOL 1 Auther - Dr Kripal singh standard Publishers Distributors 423 Automobile Engineering Vol 2 Auther - Dr Kripal singh standard Publishers Distributors 424 Mechanic Motor Vehicle theory Auther - Manish Sharma (Neelkanth publishers) 425 Mechanic Motor Vehicle Practical Auther - Manish Sharma (Neelkanth publishers) 426 Automobile Engineering Practical Auther - N Malhotra Asian Publishers 427 A Hand book for professional knowledge (Trade Theory)Mechanic Motor Vehicle Auther - ER Anoop SR New Tech Publishers 428 Automotive Mechanics Auther - S Srinivasan (MC Graw Hill Education) 429 The Automile Auther - Harbans Singh Reyat (S Chand & Company) 430 Automotive Electrical Equipments Auther - PL Kohli 431 Automobile Engineering Auther - RB Gupta 432 Motor Vehicles Act 1988, as amended upto date by The Motor Vehicles (Amendment) Act 2019 Auther - Universal Law Publishers 433 Driving Manuel (Malayalam) Auther - K S Ranaprathapan, Kerala Bhasha Institute 434 Car Driving School manuel for India Auther - Naresh Raghavan, Notion press publishers 435 Automobile Engineering(Malayalam) Auther - T M Shaji, TMS Publishers 436 Fashion design hand bood Auther - Frances Vereker 437 Embroidery Design Auther - Nirmala.C.Mistry 438 Embroidery design flowers and butterflyes Auther - Nirmala.C.Mistry 439 Design for beeds embroidery Auther - Kenneth.D.King 440 Tailoring Basics-dress design cutting and sewing Auther - Nadia Fahim 441 Embroidery stiches and technique Auther - Amazon 442 Neck Line .embroidery Auther - Sue Taylor Cox 443 Sewing school Auther - Annie Petronics 444 Simply the best sewing Auther - Amazon 445 Sewing Basics Auther - Sandra Bord well 446 High fashion sewing secrets Auther - Claire B Shaeffer 447 Complete book of sewing Auther - Amazon 448 Home tailoring course Auther -Kusum Sharma 449 Thayyal Swayam Padikkam Auther - Berlin Kadackkal 450 Thayyal Auther - J.Swarnam 451 Keraleeya Vasthra Parambariyam Auther - Dr.B.Balachandran 452 Thayyal Vinjanakosham Auther - Loosi.M.C, Roona.C 453 Thayyal entheluppam Auther - T.Raji 454 Embroidari - Kalayum Varumanavum Auther - T.Raji 455 Vasthra Nirmana Kala Auther - Sangeetha Sreevasthava 456 Thayyal Design and Dress making Auther - J.Swarnam 457 Book of Emboidery Auther - Amazon 458 A to Z of Embroidery stiches Auther - Country Bumpkhin 459 Cutting of Blouses Auther - Dilip Karampiri 460 The complete Home book of family tailoring Auther - Bonnie V Goodman 461 Designs from Indian Textiles Auther - Aparna Gwande
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
36.
Housing Urban and Rular Development #9074362 Technical Bid
Improvement Upgd Of Quality Control Material Testing Laboratory At Nagrota Jammu. By Way Of Providing Installation Commissioning Of All Lab Equipments Including All Carriages, Lifts And Leads Complete Job Including Of Application Training Impvt Upgd Of Quality Control Material Testing Laboratory At Nagrota Jammu. By Way Of Providing Installation Commissioning Of All Lab Equipments Including All Carriages, Lifts And Leads Complete Job Including Of Application Training , Pavement Core Drilling Machine:- The Pavement Core Drilling Machine, Petrol Engine Powered Road Building Drill Has Been Designed Specifically For The Purpose Of Drilling Test Cores From Or Holes In Roads, Airport Runways, Bridges. The 6Hp Petrol Engine With Pulley Mechanism Works With Minimum Vibrations. The Complete Assembly Is Supplied On A Rigid Metal Base With Leveling Facility And Is Suitable For Vertically Down Coring Applications Only. • Bit Diameter 100-150Mm ( 6 Bit Of 100Mm For Asphalt And 2Of 100Mm Bit For Concrete ) • Maximum Depth Of Core 400Mm • Drill Speed - Variable Speed From 900 To 1200Rpm • Drive - 6Hp Petrol Engine • Guide Shafts – 40 Mm Dia • Screwed Spindle – 20 Mm Dia • Water Tap – 12 Mm • Drill Wrenches - Included , Universal Penetrometer :-The Unit Is Compact With In-Built Timer To Control Duration Of Penetration Preset In Factory To 5 Seconds. The Instrument Is Provided Levelling Screws And Accessories For Bitumen & Soil Testing , Concrete Mixer:- The Mixer Consists Of A Steel Vessel Of Capacity 30 Litres. The Rate Of Rotated20-24 Rpm With The Help Of A Motor And A Pulling. The Vessel Can Be Tilted To Any Angle By A Handle. This Facilitates Mixing And Discharge. Blades Are Provided Inside The Vessel For Uniform Mixing. The Large Handle Strip Facilitates Manual Rotation Of The Drum In Case Of Power Failure. With Motor Of 1 Hp Along With Lead Wire. Suitable For Operation On 220V, 50Hz, Single Phase, Ac Supply , Curing Tank:- Accelerated Curing ( For Cooling And Boiling Water Method ) Temp. Range : 10°C To 100°C• Curing Tank For 6 Cubes Of 150 Mm, 10°C To 100°C ( With Cooling & Heating System ) , Cube Moulds:-Mould, Cast Iron, For 150 Mm Cube With Isi Certification Mark, Is:10086 , Vibrating Table :- The Table Top Is Suitable To Hold Cube Moulds Upto 6, 75Cm X 75Xm .Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. , Buoyancy Balance:-Buoyancy Balance—15 Kg X 0.5G With Nablcertification Suitableforoperationon220v, 50Hz, Singlephase, Acsuppy The Density Of Hardened Concrete Specimens Like Cubes & Cylinders Can Be Quickly & Accurately Checked Using Buoyancy Balance. The Buoyancy Balance Consists Of A Rigid Support Frame , Incorporating A Water Tank , Mounted On A Platform.Amechanical Lifting Device Is Used To Raise The Water Tank Thru The Frame Height Immersing The Specimen Suspended Below The Balance .The Balance Supplied May Also Be Used As A Standard Weighing Systeminthelaboratory. Buoyancy Balance—15 Kg X 0.5G With Nablcertification Suitableforoperationon220v, 50Hz, Singlephase, Acsuppy , Non-Nuclear Asphalt Density :- Gauge Electromagnetic Density Indication Device For Asphalt Quality Control Measurements.Lightweight Device Not Be More Than 5 Kg. Standard Astm D7113 And Aashto T 343. Displays Measurement Resultsnot More Than Two Seconds Allow To Measure Larger Areas In A Shorter Amount Of Time. Power Supply 6V 4000Mah Nickel Metal Hydride Rechargeable Batteries Battery Runtime 32 Hours ( Typical ) Battery Recharge Time 1.5 Hours ( Typical ) To 2.5 Hours ( Max. ) Weight Of Instrument With Battery 3-6 Kgs Operating Temperature Ambient 0 To 70°C ( -4 To 158°F ) Surface 175°C ( 350°F ) Max. Display 4-Line By 20-Character Lcd Data Storage Up To 999 Readings Measurement Precision ±0.20 Pcf ( ±3.2 Kg / M3 ) , Ultrasonic Pulse Velocity Meter • Display Unit, 2 Transducers ( 54Khz ) • 2 Bnc Cables 1.5 M And 10Mts • Couplant • Calibration Rod • Battery Charger With Usb-Cable • 4X Aa ( Lr6 ) Batteries • Data Carrier With Software • Carrying Case Transit Time Range 0.1 – 9999 ?S Resolution 0.1 ?S Tx Frequency Range 24-500 Khz Memory > 500 Readings Power Supply Mains / Battery ( >20H ) / Usb Cen Measure Transit Time, Pulse Velocity , Path Length, Surface Velocity, Crack Depth Time Stamp For Measurement , Rotational Viscometer :-The Rotational Viscometerperform Astm D4402 & Bis 73 High Temperature Testing Of Asphalt Binders.To Determine The Absolute Viscosity Of The Bitumen. The Viscometer Features An Electrically Heated Thermal Chamber With An Auto –Tuned Pid Controller For Precise Regulation Of Asphalt Temperatures Up To 300C. Supplied Complete With A C25 Titanium Bob & Stainless Steel Cup. Parts- • Heater Casing • Thermal Cover ( One Half Shown ) • Cup • Guard • Connector Cable • Heater Connector Rotational Speeds 10-900Rpm Shear Rate 1 / S, S-25-1000 Torque Range 0-8Nm Shear Stress Pa 10-1000 Viscosity Pas 0.05-250 The Heater Has Temperature Range Ambient Above 250°C Measuring System Din 53019 C25 , Computerized Marshal Apparatus With Data Acquisition And Software:- Astm D 5581:2007, Astm D 1559, Astm D 6927-06, Bs598-107 And En 12697-34 Load Cell And Lvdt. • The Automatic Digital Marshal Testing Apparatus Should Comply With Astm D 5581:2007, Astm D 1559, Astm D 6927-06, Bs598-107 And En 12697-34., The Test Apparatus Should Have A Load Frame Of 100 Kn Capacity, Single Speed, Robust Design For Carrying Out Digital And Modified Marshal Stability Test For 4” And 6” Dia Samples , Digital Indicator For Digital Display Of Test Results. • The Platen Movement In The Load Frame Should Be Easy And User Friendly, The Load Frame Should Have Vertical Clearance More Than 420 Mm And Maximum Horizontal Clearance More Than 250 Mm With Platen Diameter Not More Than 140 Mm. The Equipment To Be Provided With Data Aquisition System And Relevant Software. , Computrized California Bearing Ratio With Data Acquisition System And Software:- Standards Is:9669, Is:2720 ( Part 16 ) Load Frame, 50 Kn ( 5, 000Kgf ) , Capacity, Three Speed 1.5, 1.25, 2.5 Mm / Min Mould - Gun Metal, 150M Id X 175 Mm H. Perforated Base Plate - Gun Metal, For Mould. Extension Collar - Gun Metal 150 Mm Id X 50 Mm High. Penetration Piston 50 Mm Face Dia. Adjustable Bracket For Penetration Dial Gauge. Circular Metal Spacer Disc, With Detachable Handle, 148 Mm Dia X 47.7 Mm High. Annular Metal Weight 2.5 Kg, 147 Mm Dia With 53 Mm Dia Central Hole. Slotted Metal Weight 2.5 Kg, 147 Mm Dia, With 53 Mm Dia Slot. Perforated Plate 148 Mm Dia, With Adjustable Stem And Lock Nut. Metal Tripod For Dial Gauge. Cutting Collarrammer 2.6 Kg, 310 Mm Controlled Drop Rammer 4.9 Kg, 450 Mm Controlled Drop. Electronic Outfit For Cbr Test, Consists Of : Digital Indicator, 1 No.Ower : 230 ± 10% Mains, 50 Hz, Single Phase, Ac Supply D ) Parameter Display : By A Selector Switch Load Cell, 1 No. Capacity : 50 Kn ( 5000 Kgf ) , Compression Type Maximum Overload : 110% Of The Rated Capacity Sensing : Strain Gauges In Full Bridge Configuration Displacement Transducer, 1 No., Range : ±10 Mm Data Aquisition System With Software, Desktop Windows Based I5, Hp / Brothers Laserjet Printer & Ups. , Humidity Chamber :- Humidity & Temperature Control Cabinet ( Only Heating ) , Temp. Range-Amb. To 60 Deg. C. +- 1 Deg. C., Humidity-Amb. To 95% +- 3%, Double Walled, Inner Chamber Ss 304, Digital Controlled Cum Indicator. , Road Marking Thickness:- Digital Road Thicness Marking Guage-Version 5000.Mm: -12.5 Mm To +12.5 Mm Version 5000.Inch: -0.5“ To +0.5“ Changeable To -12.5 Mm To +12.5 Mm , Air Conditioner :-Providing And Commitioning Of 1.5 Ton 3 Star Split A.C Hot And Cold Along With Stablizer ( Complete Job ) , All In One Pc & Printer:-All In One Pc I5, 10 Th Generation, 8Gb Ddr, 4Gb Ram, 1 Tb Ssd, 21.5 Inch Screen, 2Gb Graphic Card, Wireless Keybord And Mouse. With Wireless Black And White Multifunctional Jet Printer. ( Print Scan Photo Copy ) , Inclusive Of Ups And Windows Installed Along With Anti-Virus And Ms-Office Complete , Asphalt Content Tester:- Ref. Standard Astm D6307 & En 12697 39. This Machine Is Used To Determine The Asphalt Ontent Of Hot Mix Asphalt ( Hma ) , Paving Mixtures And Avement Samples By Removing The Asphalt In An Ignition Furnace By Means Of Sample Heating Not By Means Of Solvents. Suitable For Operation On 415V, 50Hz, 20A, 3Phase, Ac Supply. Technical Specifications Working Temperature :540+5Oc Combustion Temperature :750Oc Balance Capacity : 10Kg Accuracy Of Balance : 0.1G Balance Capacity ( Usable ) : 2500 G Commended Weight Of Sample : 1500 G Time For Test Results : 30 To 45 Min End Point Sensitivity : 0.01% For 3 Consecutive Minutes Data Output : Through Sd Card Chamber Size : 300Mm X 340Mm X 400Mmuter Size : 590Mmx755mmx1300mm Power Rating : 5 Kw Accessories : Sample Bucket - 2 Sets, Safety Cover For Bucket 1 No. Lifting Handle - 1 No., Asbestos Gloves - 1 Pair, Safety Helmet - 1 No.Irc Accredition. , Slump Cone :-Ref. Standards Is:7320, Bs:1881, Astm C 143, Aashto T119 The Slump Cone Having Dimension As ( Id-100Mm At Top Id-200Mm At Bottom & Height 300Mm ) Is Filled With Freshly Mixed Concrete And Is Tamped With A Tamping Rod In Four Layers. The Top Of The Concrete Is Levelled Off With The Top Of The Slump Cone, The Cone Is Lifted Vertically Up And The Slump Of The Sample Is Immediately Measured. • Base Has Cleats On Its Underside To Help Dig Into The Ground Surface. • Positive Clamping Of Slump Cone To The Base While Filling And Tamping The Concrete. • A Combination Swivel Carrying Handle Also Serves As The Datum Making The Conventional And Somewhat Awkward Measuring Procedure Of Using A Foot Rule And A Datum Bar, A Thing Of The Past. , Electronic Precision Weighing Machine Range 10Kg -0.01G, Digital Display, Battery Backup, Tare Enabled Etc Complete , Wardrobe :- Almirah Of The Size, 6Feet*3Feets , Table :- Table Of The 4Feet*2.5Feet , 3000Kn Automatic Compression Testing Machine :- Loading Range: 3000 Kn ( 300 T ) Least Count: 0.1 Kn Maximum Clearance Between Platens: 400Mm Maximum Clearance Between Side Platens: 400Mm Platen Size: 320 Sq. Mm Platen Hardness: 480 Hv ( 48 Hrc ) Piston Dia: 272.2 Mm Piston Stroke: 50Mm Motor Hp: 1 Motor Make: Godrej Or Crompton Greaves Power Requirement: 220 V / 230 V, I Phase, 50 Hz, Ac Supply Specimen Size: 150Mm Cube, 300Mm Dia. Cylinder Standards: Is: 516 & Is: 14858 Unique Features Are: • Calibration Within 1% Of Full Scale Deflection With Traceability To Nabl. • Flexure Test Attachment Can Be Attached • Strain Measurement, Split Tensile Test Attachment Can Be Attached • Powder Coating Finished Surface • Front Gate For Protection • Pump With Brass Casing The Complete Unit Comprises Of: • Loading Unit – Fully Welded Construction Having A Cross Head, Base & Solid Side Plates. A Hydraulic Jack Is Fixed To The Based. The Platens Are Hardened, Ground & Polished. , The Upper Platen Is Provided With Self-Aligning Action. To Test Different Size Specimens, Suitable Size Spacers Are Provided. • Pumping Unit – This Has 0.5Hp, 1Ph, 220V Ac Motor Driven • Pid Controlled Enhanced Digital Indicator ( Edi ) ? Configurable Engineering Unit For Machine Selection. ? Predefined Machine Capacities For Each Engineering Unit. Specific Capacity Can Be Selected From The Drop ? Down Menu. ? Flexible Calibration Points. Calibration Can Be Done On 5 To 10 Points. ? Peak Load, Peak Stress, Unique Record No. Is Displayed.? Having Facility To Configure More Than One Mode. Mode1-Compression / Mode2-Flexure / Mode3-Prism Testing / Mode4-Tensile Splitting Strength. Each Mode Will Have Independent Calibration Points And Calibration Points Are Also Flexible. ? Mode-4 Runs With Mode-1 Calibration. ? Dynamic Calibration? Any Centronics Dot Matrix Printer.Two-Speed Hydraulic Pump & Bonded Strain Gauge Based Pressure Transducer.? Menu Driven Sample Details. ? Data Storage 2000 Records. , ? Data Download Thru Rs232 Inascii Format. ? User Can Set Break Point. ? Store Records Can Be Viewed & Print. ? Peak Stress Calculation Based On Sample Type And Shape . ? Password Protection For System & Calibration Setup. ? 2% Overload Facility To Calibrate The Machine Up To Full Capacity. ? Start, Stop, Pause & Reset. ? Multifunction Keyboard. ? Automatic Pace Rate Control To Set Value & Pace Rate Can Be Changed During Test Also. ? Auto Close / Release Of Dump Valve. ? Communication With Aimil Horizon Thru Serial Port ( Rs232 ) . ? Machine Can Be Operated With Software Through • Analysis & Processing Software – Windows Based Software • Continuous Voltage Transformer ( Cvt ) • Computer With Following Configuration: Desktop. ? Intel Pentium I5 Processor. ? 4 Gb Ram ? 512 Sd Hard Disk. ? Cd-Rom Drive ? Monitor That Supports At Least 1024 X 768 Resolution & 32-Bit Color ? 1 Serial Port & 2 Usb Port ? Hp / Brother Laserjet Printer. ? Ups • Nabl Accredited Calibration Certificate.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Jammu And Kashmir View Result →
37.
Educational and Research Institute #8825445 Technical Bid
Purchase , Particulars , Atomic Absorption Spectrophotometer ( Aas ) : Atomicabsorptionspectrophotometerwithgraphitetubeautomizer ( Gta ) , Flameautomizer ( Fa ) Andvapourgenerationassembly ( Vga ) , Unitforflame ( Airacetyleneandnitrousoxide-Acetylene ) , Chiller, Autosamplersforgtaandflame.: Technical Specification: Atomic Absorption Spectrophotometer: Computer Controlled With Built-Inflame Emission Mode, Wave Length Range: 180 – 910Nmwave Length, Sensitivity: Sensitivityatleast0.35Absfor5µg / Mlaqueouscopperstandardsolutionwithair – Acetylene Flame., Optics: Double Beamholographic Monochromator, Czerny Turner , Focallength: Atleast250mmfocallength, Resolution: 1800Lines / Mm, Slit Width: 0.1Nm, 0.2Nm, 0.4Nm, 1Nm, 2Nm & 5.0Nm ( Six Step Auto-Changer ) , Flame Atomizer: Alltitaniumor Equivalentburnerwithimpactbead / Flowspoiler, Premixdesign, Movement: Automatic Movementintothe Sample Compartment, Affect From Acids, Organic Solvent: Unaffected From Attacks By Acid Solution Or Organic Solvents ( E.G. Methylisobutylketone I.E. Mibk, Flame Alignment In Liquid Beam:Fullyautomatic, Optimizedwithmotorizedburnermountforverticalandhorizontalburneradjustment, Nebulizer:Highprecisionabletoprovidemanuallyadjustableuptakeratesmaterialofthenebulizerandrelatedventurishouldbeinerttoacidsolutionsandorganic Solventssuchasmibk, Flame Control: Computercontrolledignition, Gas Control: Computercontrolledwithoxidantandfuelgasesmonitoringtomonitorconstantfuel / Oxidantrationignition., Safety Function: Interlockingsystem To Preventignition, Essential Interlock Monitor: Burnertypeaswellasitspresenceinposition, Airselector, Flamesensor, Liquidtraplevel, Gassupplypressureandairsupplyanywhere Inthe Networkofgastubings Inthe System, Automatic Lamp Selection Function: Computer Controlled Hollow Cathode Lamp Selection And Alignment, Lamp Holder: Atleast8lampholderwithbuiltinpowersuppliesforhollowcathodelampsandelectrode–Lessdischargelampsorequivalent, Operating Parameter Setting: Automatic Setting, Read Out / Display: Displayfacilityforabsorbanceaswellasconcentration, Displayoferrorsorerrorcodes, Absorbancerangeat Least Upto 2.0 Abs., Scale Expansion: Scale Expansionatleastupto 100X, Integration Time: Integrationtime Shouldcoveratleast0.1To 60 Secondsrange, Measurement: Measurementsofmean, Rsdandcv, Backgroundonlymode, Integration Ofpeakheightandpeakareas.Accessories / Spares With Flame Aasystem, Vapor Generation Assembly: Shouldbecontinuousflowbasedhydride / Mercuryvaporgeneratorwithoptionofusingwithorwithoutaprogra, Mmable Auto Sampler Highly Automatic: After Pressing The Start Key, The Whole, Process ( Sampling, Reacting, Calibrating And Cleaning ) Will Be, Finished Automatically.High Sensitivity: The Sensitivity Of Most Elements Is Better Than 1Ng / Ml / 1%A. Sensitivity Of Arsenic Is Better Than 0.15Ng / Ml / 1%A.Rsd: Less Than 3% Measurement Time: The Single Measurement Will Take 25 To 35 Sec, Less Solution: Sample 2-2.5Ml ( Including Clean ) , Potassium, Borohydride 1-1.5Ml, Carrier Liquid 5-6Ml.Atomizer: Heated Absorption Cell ( Heated By Air-C2h2 Flame In Standard Carrier Gas: Ar Pressure: 0.32 Mpa, Consumption:70 Ml / Min, Power Requirements: 240 Vac, 50 / 60 Hz, Precision: Precisionofbetterthan Oratleast1%Atppblevelsofmercury, Arsenic Etc. Absorption Cell: Theabsorptioncell’Smaterialshouldhavenoeffectofthehighheatof The Flame Andthe Cellforthe Analysis Ofmercuryshouldbeofa Closedabsorptiondesign Flame Arrester: Flamearrestershouldbeprovidedinthetubewhichconnectsthe Assemblyto The Absorptioncell, Cell Design Holder: Thedesignofthecellholdershouldgiveafirmandeasilyadjustable ( Foralignment ) Mountingonthe Burnerhead. System Accessories: Complete Withnecessary Reagentbottles, Connectorsetc.Hollow Cathode Lamps: Arsenic, Antimony, Calcium, Chromium, Cobalt, Copper, Iron, Nickel, Lead, Manganese, Mercury, Tin, Zinc, Molybdenum. Air Compressor With Air Filter Or Equivalent Air Service Unit:Completewithpressureregulatorquiteinoperation, Necessarytubingandconnectorsandshouldmeettheairsupplyrequirements Of Aasoperation.Oil Free Pump: Oil- Free Pumpandmoisture Trap, Corrosion Resistant: Resistanttoacidic Vapourandthedrainvalve ( If Any ) Shouldbemade Of Stainlesssteelof Equivalentcorrosionresistantmaterial Nitrous – Oxide Gas Regulator: Nitrousoxidegasregulator ( Twostage ) Withheater, Withnecessarytubing’Sandconnectors.Necessarytransformershouldbeprovidedto Transformthissupplyto Therequirementsoftheheater.Theheatershouldworkon230±10Volts50hzacpowersupply.Acetylene Gas Regulator: Acetylene Gasregulator ( Twostage ) Withnecessarytubingandconnectors.Nitrogen Gas Regulator: Nitrogenregulator ( Twostage ) Withnecessarytuningsandconnectors.Graphite Furnace System, Graphite Tubeatomizer: Should Becomputercontrolledfullyenclosedgraphitetubesystemconsistingofstabilizedtemperature / Totalpyrolyticgraphite Plateform.Gassupplies: Provisionoftwogassupplies ( Programmeselectable ) Withindependentcontroloverthe Gassupplythroughthe Furnace.Heatingrate: Heatingrate Ofatleast2500°Cpersecond Coolingtime: Coolingtime20seconds Temperature Range: Temperaturerangeambientto 3800°Cor Morein 1°Cincrementsfeedbacksystem: Feedbacksystemforfurnacetemperaturecontrol, Interlocksforwater, Gas, Temperature, Furnacedoor, Graphitetubedamage Andmainspower.Temp.Programming Upto 20 Rdertemperatureprogrammingfacilitywithflexibilityofprogramselection, Ramptime, Gases, Gasflowandreadtriggerforeachtemperature Step.Control Computercontrolledwithappropriateprovisionforprintoutofthe Furnace Andsample Parameters Display Calibrationdata / Graphs, Temperatureprofiles, Signalgraphicsandthe Instrumentstatus. Memory Memoryshouldbe Ableto Storeatleasttwenty Fivenonvolatileprogrammes Chiller Cooling Mode: Compressor Cooling, Temperature Controller: Pid Controller, Temperature Range: 5°C – 35°C, Accuracy: ±1°C, Cooling Capacity: 1300W @25°C, Pump Pressure: =1.3Bar, Pump Flow: =15Litre / Min, Tank Volume: 8 Litre, Tank Material: Stainless Steel Ss304, Refrigerant: R134a Size ( W*D*H ) : 360*450*653Mm, Power Supply: Ac220v, 50 / 60Hz Dataworkstation Application Softwareprogram Facility With Multitasking Software Shouldprovidecompletecontrolofinstrumentwithinstrumentstatusdisplayanditsvariousaccessories. Provide Accurate And Reproducible Time Averaged, Integration, Non – Averaged Integration, Multi Level Calibration. Softwareshouldhandleinstrumentlinearabsorbancereading, Concentration, Oremissionintensity, Integrationtime, Built-Instatistics, Calibrationequationcontrol, Slopeofanalyticalcurveusingoperatorselectivecalibrationstandard Built-Ininterfaceforcomputerconnectionanduseofoptionalaccessories. Comprehensivequalitycontrolprotocolsfacilityincludingblank, Multiplequalitycontrolstandards, Qa / Qcaudittrailandcalibrationfailure. Computer System, Make Reputed Brand, Processor I5 -10Th Gen, Ram 8Gb Or Advance.Ssd 512, Monitor 19”Led, Operation Software: Preloaded Windows Xp Professional Operating System With Licensed Cd Or Better Msoffice2000standardwithmedia, Manualandlicensedcdor Better, Preloaded Antivirus With Latest Version Along With Licensed Cd Or Better Fume Hoodexhaust Fume Hood Made In Stainless Steel Chimney With Std 20Ft Ss304 Powder Coated Exhaust Pipe With Inert Centrifugal Blower 1400Rpm, Ac 230V, With Standard Fitting Installation Hardware For Installation. Operation Kit Standardoperationkitincludingallrequireditems, Tubings, Fittingsforstartup / Regularoperationofinstrumentsuchasgaspurificationsystem To Be Supplied With The System. Operation / Maintenance Manual Operation / Maintenance Manualforeachunit Analytical Manual Analyticalmanualincludingapplicationsforflame, Vgaandgraphite System Operation And Maintenance Training One Weektrainingto Beprovidedtotwo Scientiston Softwaretraining, Operation, Maintenance Andtrouble Shootingaspectsof Instrumentatthe Timeof Installation. , Air Conditioner : Split Ac With Inverter Swing Compressor: Streamer Discharge & Dew Clean Technology For Healthy Air Capacity 1.5 Ton: Suitable For Medium Sized Rooms ( 111 To 150 Sq.Ft ) 5 Star: Best In Class Efficiency Copper Condenser Coil: Better Cooling And Requires Low Maintenance Key Features- Cooling Capacity @ 43°C: 100%; Noise Level: 38 Db ( A ) ; Ambient Operation: 54°C Special Features: 15% Higher Iseer Compared To Base Iseer ( 4.5 ) Of 5 Star Ac; Patented Streamer Discharge For Healthy Air; Intelligent Eye To Adjust Cooling According To Human Presence; Triple Display ( Power Consumption %Age, Set / Room Temperature & Auto Error Code ) ; Dew Clean Technology That Cleans Indoor Unit Coil With A Press Of Button Refrigerant Gas: R32 Environmental Friendly - No Ozone Depletion Potential Indoor Unit, Outdoor Unit, Remote Control, User Manual, Warranty Card & Standard Installation Kit , Bod Incubator: Floor-Standing, Double Doors .Temperature Range 5°C To 80°C With Uniformity Of ±0.2°C @ 10°C. Microprocessor Pid Controller Delivers Superior Temperature Control Accuracy, Required For Precise Results. Features And Advantages Include Illumination Lamp, Caster Wheels For Easy Mobility, Digital Timer . 175Litres / 6.1Cft, External Chamber Ms, Internal Chamber Ss304, Solid Insulated Door ( With Glass & Without Glass ) W / Lock Door, Stainless Steel 5 Shelves Removable, Caster Wheels, Humidity System, Light System By Interior Illumination W / 3 Fluorescent Tubes, Timer 0-99 Hours For Regulating Cycles Illumination Condition, Rfid Enabled Door Locking System. Brand Name And Model Name Must Come In The Display. , Centrifuge: Max Speed: 15000 Rpm Speed Accuracy : ±1Rpm Or ±1 X G Temperature: -10°C To +40°C. Possibility Of Precooling During Standstill Rotor Type: Angle Rotor For Conical Centrifuge Tubes. All Rotors With Lid And Anti-Corrosion Coating Rotor Capacity: 8 X 50 Ml With Max. Rpm:~14000 Rpm 8 X 15Ml With Max. Rpm:~ 14, 000 Pre Selection Of Run Parameters In Terms Of Rpm Timer Range: Pre Selection Of Time From 30Sec. To 10 Hr. Or Continuous Set Time In Hrs:Min, Min:Sec, Or Continuous Mode Automatic Rotor Identification & Imbalance Sensor Low Vibration During The Operation. Extremely Low Noise During Operation ( <66 Db ) . With Microcontroller For Speed, Time And Temperature Motorized Lid Lock And Inter Lock Keys For Start, Stop And Lid Open Power Supply: 230 V / 50-60 Hz , Chns Analyser : Fully Automated Pc Controlled Elemental Analyser For Solid And Liquid Samples.The Analyzer Must Be Able To Simultaneously Determine The Elements In The Following Combinations: Chns, Or Chn, Or Cns, Or Cn, Or Nwithout A Need To Change Column Helium As Carrier Gas And Option For Argon As Carrier Gas In Chns Mode.Sample Weight Range: 0.2 Mg Of Organic Compound To 800 Mg Or More Inhomogeneous Soildetection Range: 0 To 100% For All Elements ( C, H, N, S ) With The Capability Of Measuringat Least 10 Mg Absolute Carbon In Chns Mode And More Than 50 Mg In Cn Mode Standard Deviation: ?0.1% Of Absolute. Lower Detection Limit Of < 50 Ppm For N , C And S With Thermal Conductivity Detector ( Tcd ) Dependingon Sample Weight. The Instrument Must Fulfil The International And National Safety Standards. For Safety Reasons, Theentire Instrument Including Furnaces Must Internally Operate On Low Voltage ( < 50 V ) . Large Dynamic Measurement, Range From 0.1 Milligram, Chemical Substance To1 Gram Inhomogeneous Soil, Best Analysis Results For Any Sample Matrix, Wide Variety Of Optional Configurations, Individually Extendible, Low And Tool-Free Maintenance, Low Noise Level, Low Total Cost Of Ownership, Integrated 120 Position Auto Sampler As Standard, Patented Ball Valve Forblank-Free Sample Transfer. Furnace System • Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace In Chns Mode. Easy Slide-Out Mechanism Of Furnace For Routine Maintenance Work. It Should Be Possible To Set Difference Temperature For Combustion And Reduction. • Controlled Furnace Temperature Should Be 1200 Deg C Or More. • Easy Ash Removal Without Change Of Combustion Tube By Means Of An Exchangeable Ash Crucible. Separation System • Combustion Gases In The Form Co2, H2o, N2 And So2 Are Separated By Means Of Single Temperature Programmed Desorption ( Tpd ) Column. Detector System • Oxygen Intrusion Free Thermistor Technology-Based Temperature Stabilized Tcd Detector For Measurement Of C-H-N-S-O Auto Sampler System • Integrated 50 Or More Position Automatic Sampler Having Capacity To Handle Upto 1000 Mg Sample In Each Sampler Holder Position Of Carousel Software • Should Be Windows Based And Should Have Operating Software With Automatic Calculation And Statistical Evaluation Of Sample Results, Automatic Leak Check, Sleep / Wakeup Function, Gas Stop, Service And Maintenance Support And Weight Transfer From External Balance. • All Instrument Functions Incl. Gas Flow And Pressures Must Be Digitally Controlled For Diagnosis And Trouble Shooting Via The Internet. Consumables: To Be Supplied With Consumables Enough For 1, 000 Sample Analysis In Chns / Cns Mode. Necessary Documents: - • Catalogue In Original. • All Technical Specifications Should Be Printed On The Manufacturers Catalogue / Data Sheet. , Compound Microscope : Compound Microscope ( 10X Eye Piece, Objective With Magnifying Powers 10X, 40X And 100X Oil Immersion Objective Lens ( Body - Monocular Die-Cast Body, Inclinable Upto A Horizontal Position ( 90° ) ; Focussing - By Coarse & Fine Focusing Knobs; Eyepieces - Huygenian 10X And 15X; Objectives - Hard Anti-Reflection Coated, Colour Coded Par Focal Achromatic 10X, 40X, 100X, Oil Immersion; Condenser - Built-In Sub Stage Condenser With Iris Diaphragm. Branded, Best Quality ) , Compoundtrinocular Microscope With Camera: Trinocular Head, Eyepiece: Swf 10X, U Plan Objectives Of 4X, 10X, 40X And 100X, Abbe 1.25 N. A. Condenser With Iris Diaphragm, Ceramic Coated Flat Top Stage, Co Axial Coarse And Fine Focusing, Led Or Halogen Illumination With Automatic Voltage Sending Power Supply, Digital Camera ( 5 Mega Pixels ) , Fire Wire Cable, C-Mount Adapter 0.7X And Image Analysis Software With 4D Experiment Ability. , Conductivity Bridge : Advanced Microprocessor Based Design. Brand Name And Model Name Must Come In The Display. Conductivity And Tds Modes. Automatic And Manual Temperature Compensation Auto Ranging. 0-20?S / Cm, 20-200?S / Cm, 200-2000?S / Cm, 2 – 20 Ms / Cm, 20-200 Ms / Cm, 200Ms / Cm -2000. Multi Point Calibration. Tds Conversion Factor From 0.40 To 1.00 Cell Constant Adjustable From 0.1 To 10.0 Temperature Coefficient Adjustable From 0 To 10% / °C Normalisation Temperature Adjustable From 15 To 30 °C. Bi Directional Rs232 Interface. Baud Rate Selectable From 1200, 2400, 4800 And9600. Single And Continuous Print Out Of Conductivity. Multiple Printout Types. Combinations Selectable From Sr. No., Cond / Tds, Date, Time And Temperature. Real Time Clock. Temperature Setting ( Manual Temperature Compensation ) . Calibration Report As Per Glp Requirements Lcd Touch Screen Display With Backlight. Memory Storage Of 100 Measurements. Data Logging Facility Up To 500 Results. Data Logging Interval Selectable From 5S, 10S, 20S, 30S, 1M, 2M And 5M. Temperature Calibration. , Compound Phase Contrast Binocular Microscope : Body: Binocular, Sturdy, Stable Base Body With Focus Adjustment Controls. Eye Piece: Paired, High Quality, Achromatic, Wide Field, System Complete With Illumination System Is Required. Objective: Three Objectives 10X, 40X, 100X. 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively.100X Should Have Numerical Aperture Of 1.65. Nose Piece: Revolving Nose Piece To Accommodate A Minimum Of Three Objectives With Click Stops. It Should Be Provided With Ribbed Grip For Easy Rotation Mounted On A Precision Ball Bearing Mechanism For Smooth And Accurate Alignment. Stage Uniformly Horizontal, Mechanical Stage Having Dimensions Of Length 140 Mm ( + / - 20Mm ) . The Stage Should Be Provided With Spring Loaded Slide Holder For Exact Positioning Of Specimen / Slide. The Stage Should Have Ball-Bearing Arrangement To Allow Smooth Travel In Transverse Directions I.E. 80 Mm ( + / -10Mm ) And Front To Back Direction, 50Mm ( + / - 10Mm ) . The System Should Have A Build-In Variable Light Source ( Illuminator ) . This Light Sourceshould Have A 50 W, 12 V Halogen Lamp. All Consumables Required For Installation And Standardization Of System And Microscopecover To Be Given Free Of Cost. , Desktop Computer With Accessories : Corei5-11400 Motherboard-Gigabyte H510mh , 16 Gb Ddr4 Ram, 512 Ssd, Key Board, Mouse, 19”Led Colour Monitor, Bluetooth, Cabinet, Branded Laser Printer. , Digestion Hood For The Laboratory : Internal Lining: Suitable Material For Hf Resistancelike Upvc Or Pp Internal Size ( 1600X675x1250 Mm : Wxdxh ) ± 10%Should Supply With Digital Face Velocity Meter Withalarm / Low Exhaust Indicatorcold Water Service Fixture ( Inlet And Outlet, Pre-Plumbed ) For Using Distillationunit Inside. Tri-Wall Construction For Maximum Robustness. U-Pvc / Pp Internal Chamber. Chain And Sprocket Sash Support System. Hood Lighting Is Pre-Wired. Lighting Is Electronically Ballasted, Energy Efficient, Instant Start. Typical Light Intensity On Work Surface Is >1076 Lux In Zero Ambient Conditions. U-Pvc Exhaust Collar Ensures Superior Chemical Resistance. One Gas Service Fixture-Pre-Plumbed Internal Electrical Connection: Two Number ( 5 / 15 Amp ) Socket Internal Light Fitting For Proper Illumination With External Switches Vertical Sash: Polycarbonate / Toughened Float Glass ( Acidresistant ) Removable Baffle / Suitable Mechanism For Easycleaning, Blower And Duct: Pp+Frp – 250 Mm Diameter Duct 20 Feet In Length 1 Hp Motor And Reputed And Standard Company ( Brand Must Be Mentioned ) , 600 Cfm Minimum Volume Weather Proof Pp / Motor Housing. Exhaust: Pp+Frp Exhaust Fan With Chemical Resistantimpeller System Will Be Installed In First Floor Of Laboratory Block. Stack Height Should Beat Least Three Meters Above Top Roof ( Two Storey Building ) Shaping Vanes Increase Airflow “Sweep” At The Critical Area Atthe Sidewall To Improve Containment, Especially When Laboratorypersonnel Walk Fast In Front Of The Hood. , Electronic Precession Balance : Maximum Capacity [ Max ] 200 / 2000 G Minimum Load 20 Mg, Readability [ D ] , 0.001 / 0.01 G Tare Range-2000 G, Repeatability ( Max ) 0.001 / 0.01 G Repeatability ( 5% Max ) 0.0005 / 0.005 G, Linearity±0.002 / 0.02 G Stabilization Time2 / 1.5 S Adjustment External Physical Parameters Levelling System Manual Display Lcd ( Backlit ) Delivery Components Balance, Weighing Pan, Weighing Pan Shield, Grounding Foot ×1, Foot ×3, Power Supply. Weighing Pan Dimensions 128×128 Mm Packaging Dimensions 470×380×336 Mm Net Weight-3.2 Kg Gross Weight 4.8 Kg, Protection Class Ip 43 , Communication Interface Communication Interface, 2×Rs232¹, Usb-A, Usb-B, Wi-Fi® ( Option ) Electrical Parameters, Power Supply , Adapter: 100-240V Ac 50 / 60Hz 0.6A; 12V Dc 1.2A Balance: 12 – 15V Dc 0.4A Max , Environmental Conditions Operating Temperature +10 — +40 °C. , Environmental Shaker :Environment Shaking Incubator : Salient Features , Programmable Logic Controller ( Plc ) , 4.3 Hmi With Colour Display And Touch Screen, Password Protected Operation. , Universal Platform To Accommodate Vanous Type Of Flask And Test Tube Rack Max ( 8X250ml ) .Electronic Capacitance Type Humidity Sensor , Direct Display Of Temperature And Humidity, Display Of Set Value And Process Value, Unique Air Flow System Ensures Even Distribution Of Temperature And Humidity, Precise Control Of Temperature And Humidity By Using Built In Pid Controller ( Auto Tuning Type ) , Forward And Backward Rotation Programs And Rpm 30-350, Maintenance Free Brushless Induction Motor, Variable Frequency Drive ( Vfd ) Permanently Lubricated Bearing For Noise Less Operation, Triple Eccentric Counter Balanced Drive Mechanism For Uniform Agitation, Castor Wheel For Ease Of Mobility Adjustable Levelling Jack. , Horizontal Autoclave : 1.Fully Automatic Micro Processor Based High Pressure, High Vacuum Autoclave For Sterilizing Material Including Agars, Sterilization Of Solution In Open & Closed Bottles, Disinfection Of Materials And Waste Decontamination. 2. Should Be Front Loading, Have Rectangular, Horizontal Chamber With Well Insulated Jacket, Chamber Volume Minimum 165 Lit. 3. Should Have Single Vertical Sliding Door To Have A Pass Through System. Door Should Be Electrically Controlled Having Fully Automatic Function With Multiple Safety Arrangements. Sealing System Should Be Based On Silicone Seal.4. Should Have At Least 50Mm Thick Insulation Materials On Jacket And In Doors To Ensure Low Thermal Losses. Working Temp. Of The Door Should Be Less Than 45Deg. C. 5. Should Be High Grade Stainless Steel.6. Should Have A Built In Colousr Touch Screen.7. Should Have Audio Visual Alarms In Case Of Undesired Situations. 8. Should Have Programmable Operators Access Level. 9. Should Have At Least 10 Pre Programmed Standard Cycles Plus 5 Or More User Programmable Cycles And Provision Of Chip Card Port For Loading Of New Programs Through Chip Cards.10. Should Have Temperature Adjustable From 25Deg. To 135 Deg. C. 11. Safe Working Pressure Range Should Be Adjustable 12. Should Have Complete Monitoring Of Cycle Operation And Provided With At Least Two Pressuresensors And Two Temp. Sensors ( Pt -100 ) In Addition To Analog For Chamber Pressure, Jacket Pressure And Steam Generator Pressure Indication.13. The Unit Should Be Equipped With Multiple Safety Mechanisms For Emergency Stop Over Pressure Safety Valves For Chamber And Jacket, Over Temp Safety, Steam Traps And Electrical Safety.14. The Unit Should Include Non Fade Built In Thermo-Recorder For Step Progress Values During The Cycle With Time And Date And Alarm Condition If Any.15. Should Have Built In Feature Of Water Saving System For Water Conservation.16. Should Be Supplied Complete With High Quality Stainless Steel Trolleys And Sterilization Baskets: A. External Trolley = 01 Nos.B. Internal Trolley With Steel Roller C. Shelves = 01 Nos. And D. 2 Sets Of Sterilization Baskets. 17. All Accessories & Electric Fitting To Be Included 18. Three Compulsory Visits For Calibration And Check-Up Irrespective Of Complaints In Year.19. The Steam Generator Should Be Also Be Made Of Aisi 316 Ti Steel & The Steam Generator Should Be Equipped With Automatic Cleaning Facility. 20. Integrated Waste Water Cooling, Integrated Water Saving Device. Touch Screen Display, Chip Card Reader And Rs 232 Interface. , Hot Air Oven : Capacity 250 Litre, Temp Range: +5ºc To 250ºc. Control Accuracy: ±0.2ºc, Uniformity: ± 2.0 At 100.0ºc Minimum 3 No. Of Shelves With Height Adjustable In 25Mm Steps, Glass Window In-Built Into The Door For Easy Viewing Of Samples, Automatic Cut Off Of Heater & Blower When Door Opened, Digital Pid Temperature Controller With Timer, Alarms And Auto Tuning, Aero Dynamic Internal Design For Achieving Horizontal Air Circulation, Solid And Plain Bottom Without Electrical, Outer Body Made Of G.I Epoxy Coated Inner Body Made Of Stainless Steel With Clear Bottom Ce Certified. Brand Name And Model Name Must Come In The Display. , Hot Plate : Size 420 X 320 X 130 Mm Ht. ( Total Height With Feet ) Weight 9 Kg, Voltage 230V ( 50Hz ) , Temperature 250°C Maximum Uniformity + / - 2°C.Temperature Rise 6°C Per Minute Temperature Drop 1°C Per Minute, The Hot Plate Should Be Able To Control The Temperature Within + / - 2°C, Temperature Should Be Uniform Throughout The Hot Plate Surface. 6. There Should Be Rims Around The Edges Of The Hot Plate For Safety, Power 2200 W, Approx. 9.6 Amp In 230V, Material Pfa Coated Graphite. , Laminar Air Flow Chamber : Microprocessor Controlled System With Motorised Door. Type Of Airflow: Horizontal Full Password Protected Operation. 70% Of Air Should Be Recirculated To The Cabinet Work Area Through Hepa Filter And The 30% Balance Should Be Exhausted Through Hepa. The Balance Should Be Dynamic To Ensure The 70 / 30 Recirculation / Exhaust Air The Instrument Must Have Hepa Filters On Down Flow As Well As Exhaust With An Efficacy Of 99.99% For Particles Sized Of Calibration Certificates Along With Dop Test Report Shall Have To Be Submitted At The Time Of Supply Of Instrument ) The Dimensions Of The Working Chamber Should Be In The Following Range: Length: 90-120 Cm , Width: 40-60 Cm , Height: 50-80 Cm . The Main Body And Working Chamber Of The Cabinet Should Be Made Of Stainless Steel, Rigid And Rustproof With Removable Trays The Cabinet Should Have An Electrically Operated Sliding Front Sash Made Of Safety ( Uv ) Glass With A Provision For Manual Operation Of The Sliding Front Window. Also, The Sliding Front Sash Should Have True Air And Aerosol Tight Electrical Shahs. Front Door: Clear Transparent Sturdy Material Work Chamber Should Be Fitted With A Fluorescent Lamp For Illumination And Should Have Programmable Uv Light Cycle. The Unit Should Have Microprocessor Control Keys With Large Icons And A Large Graphical Display With Provision For The Permanent Display Of The Following Key Cabinet Conditions. I. Inflow And Down Flow Air Velocity Ii. Exhaust And Recirculated Airflow Volumes Iii. Time And Date Iv. Residual Lifetime Of Filters & Total Time Of Cabinet Operation ( Optional ) Alarm Notification In The Following Situations: I. Low Inflow Velocity Ii. Low Down Flow Air Velocity Iii. Hepa Filter Life Iv. Alarms For Clogged Filters V. Other Malfunction Compatible At A Power Supply Of 220 V, 50Hz Noise Level: < 65 Db Basic Cabinet Should Be Termite And Insect Resistant And Washable Accessories: Manometer, Gas Inlet, Castors The Cabinet Should Be With A Stand With Lockable Castors Brand Name And Model Name Must Come In The Display. , Multimeter With Ion Selective Electrodes For Water Quality Testing : Colour Capacitive Touch Screen With Software Control Facility. Can Store 2000 Sets Of Test Data, Which Can Be Saved And Transferred To Usb Memory Stick And Opened With Excel. Power: Universal Ac Adapter And With Rechargeable Lithium Battery ( Included ) . Concentration Range: ( 0~19990 ) , Can Switch 6 Kind Of Concentration Units: Ug / L, Mg / L, G / L, Mol / L, Mmol / L, Ppm. Concentration Resolution: 4 Significant Digits ( Expressed In Scientific Notation ) Can Be Operated Through 5 Amp Plug And Battery. Accuracy: ±0.1Mv Or 0.03% Temp Range: ( 0? To 100? ) Accuracy: ±0.1? Output Through Usb / Bluetooth Battery Life 1000 Hour. Type: Lithium Battery. Ise- Fluoride, Chloride , Bromide, Ammonia, Brand Name And Model Name Must Come In The Display. , Mechanical Shaker: Compact Bench Top Microcontroller Based Shaker With Temperature Control Range From Ambient +5°C To 60°C , Ergonomicallydesignedwithminimalfootprint Triple-Eccentriccounterbalanceddriveforuniformagitationwith 25Mmshakingorbitmaintenance Freepermanent ( Self ) Lubricatedshieldballbearingsfornoiselessoperationfrpexteriorwithanti-Vibrationmountforsmoothrunning Preciseshaking Speedcontrolwithgentlestart / Stopcycle, Preventingspillagepowerfulpermanentmagnetdcdrivewithdigitalleddisplayofspeed Pulsewidthmodulation ( Pwm ) Basedspeedcontroloptionaltimerfunctionforspeed Autore-Starttosetspeedafterpoweroutage Universalplatformtoaccommodateerlenmeyer, Roundbottom, Volumetricflasks, Testtube Holders&Microplateholders Hasautorestartfunctionafterpowerinterruptionwithnonvolatilememory ( Retainsetparametersafterpowerfailure ) Orbital Shaking With Orbit Diameter Of 25 Mm, Speed 20-450 Rpm With Accuracy Of ± 2 Rpm, Led Display , Universal Platform And Clamps To Hold Flaskscapacity 100Ml-64Nos Or 1000Ml. -16Nos, Tray Dimension : 450 X 450 Mm, Noiseless Operation, Operational Voltage - 220 ± 20V, 50 Hz, Should Meet Ce Standards , Mechanical Soil Auger : Soil Auger Sampler : Made Of Iron : Screw Type, One Meter Long With Handle :Size : 2.5 Cm. Dia , Microprocessor Based Flame Photometer : Alphanumeric Graphics Lcd ( 240X 128 Dots ) Brand Name And Model Name Must Come In The Display Microcontroller Based Na, K, Li, Ca& Ba Auto Ignition Gas Leak Sensor Auto Gas Cut Off. Pass Word Protection. Separate Logging For Guest And Administrator Quadratic Curve Fitting Rtc High Quality Compressor Software Na Minimum Concentration Without Dilution 2 Ppm And 0 -200 Meq / L With 1:100 Dilution Ba Can Be Measured Upto 3000Ppm Without Dilution In Higher Concentration Mode And 500Ppm At Lower Concentration Mode. Caupto 250 Meq / L With 1;100 Dilution Bandwidth 10Nm Curve Fitting Accuracy ±2% F.S Pc Link Software To Send Data To Pc. Gas Cylinder And Regulator Must Be Supplied. Product Must Be Ce Certified And Company Should Bear Iso Certification. Brand Name And Model Name Must Come In The Display. , Microtomy : Section Thickness Range: 0.25 - 60 ?M Trimming Thickness Range: 5 - 500 ?M Resolution: 0.25 For 0.25 - 1 ?M 0.5 For 1 - 5 ?M 1 For 5 - 20 ?M 2 For 20 - 30 ?M 5 For 30 - 60 ?M Resolution: 5 For 5 - 10 ?M 10 For 10 - 100 ?M 20 For 100- 200 ?M 50 For 200 - 500 ?M Knife Carrier Retraction During Return Travel Of The Specimen: 60 ?M Horizontal Feed Range Of The Knife Carrier: Max. 28Mm Vertical Specimen Stoke: Max. 64Mm Specimen Size: 55 X 50 Mm Specimen Orientation: X And Y Axes: Universal 8º Z Axis: Up To 360º , Microwave Digestion System : Large Furnace Cavity Design With Completely Independent Intellectualproperty Rights, 1~6 100Ml Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; Industrial Grade 1000W Magnetron. Temperature And Pressure Dual Measurement And Control, Precise Control, Active Prevention Of Over-Temperature And Over-Pressure, Maximum Working Pressure: 6Mpa, Maximum Withstand Temperature: 300°C, Maximum Working Temperature: 250°C High-Precision Anti-Interference Pressure Sensor Adopts Double Explosion- Proof Control Mode To Directly Measure The Actual Reaction Pressure In The Digestion Tank, The Pressure Measurement Range Is 0~10Mpa, And The Pressure Measurement Accuracy Is 0.01Mpa; Insert High-Sensitivity Platinum Resistance Temperature Sensor, Directlymeasure The Actual Reaction Temperature In The Digestion Tank, The Temperature Range Is 0~300°C, And The Temperature Measurement Accuracy Is ±0.1°C; It Can Measure And Control The Pressure And Temperature In Any Reactiontank, And The 7-Inch High-Definition Camera Display Accurately Shows The Chemical Reaction Process; Equipped With Perfluorination Digestion Tank Or Ft Double-Layer Digestion Tank: Ptfe Digestion Tank Is Made Of Ptfe ( Polytetrafluoroethylene ) , And The Sheath Is Made Of High-Strength Explosion-Proof Aerospace Composite. The Fiber Material Is Made By One-Time Die-Casting, High Temperature Resistance, High Pressure And Strong Acid Corrosion Resistance; Easy Disassembly And Assembly, Fast Cooling; Double Venting Protection And Digestion Tank For Venting Holes And Sealed Bowls; Up To 6 Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; The Furnace Cavity Is Ventilated With Acid Resistance, Large Air Volume Centrifugal Fan, And The Exhaust Air Volume Is 5M3 / Min; Specially Designed Self-Locking Ground Moving Safety Door To Resist Accidental Explosion And Microwave Leakage. Tank Technical Parameters: The Pressure-Resistant Jacket Material Is A Hydrophobic High-Strength Pressure-Resistant Composite Fiber Material, Which Is Explosion-Proof And Supports Washing And Easy To Clean. The Inner Tank Adopts Imported Modified Polytetrafluoroethylene ( Tfm ) , High-Strength Frame Type Closed Ultra-High Pressure Reaction Tank: The Highest Withstand Temperature =300 °C. Explosion-Proof Membrane Automatic Pressure Relief And Peek Compressionmodule Pressure Relief Safety Design To Ensure The Safe Operation Of The Instrument. The Whole Tank Pressure Monitoring System, The Threshold Value Can Beadjusted. Using High-Strength Engineering Plastics For One Injection Molding, Independent Ultra-High Pressure Digestion Tank Holder. Tank-6Pcs, Power- Ac220v / 50Hz / 10A, Microwave Frequency-2450 ( Mhz ) , Microwave Output Power-1000 ( W ) , Microwave Cavity-45 ( L ) , Protective Spraying- Pfa, Control Heating Method- Pid, Temperature Ramp-1~50? / Min, Cooling Time-=25Min, Microwave Leakage-=0.3Mw / Cm2, Temperature Control Range-0~300?, Temperature Control Accuracy-0.1?, Pressure Control Range-0~10Mpa, Pressure Accuracy-0.01Mpa, Outer Tank Material- Peek, Inner Can Material- Tfm1700, Highest Temperature Resistance-300?, Operating Temperature-250?, Highest Pressure-15Mpa , Microwave Oven : Convection Microwave Oven With Ceramic Enamel Cavity 21L ( 1. Capacity: 0.7 Cu.Ft. / 21 Ltr., 2. Heat Source: Convection 3. Power: Power Consumption ( Microwave ) 4.1200W 5. Power Source: 230V / 50Hz 6. Output Power ( Max ) : 2350W 7. Powerlevel:6 8. Display Type: Led Bar 9. Control Method: Membrane 10. Door Opening Type: Handle 11. Microwave Distribution: Turntable 12. Cavity Interior :Ceramic Enamel ) , Millipore Water Purifier : Parameter Value Or Range Pressure 2 – 6 Bar Flow Rate > 10 L / Min At 2 Bar Feed Water Type Potable Water Temperature 5 – 35 °C Conductivity 10 – 2000 ?S / Cm At 25 °C Ph 4 – 10 Hardness ( As Caco3 ) < 300 Ppm Silica Concentration <30 Ppm Carbon Dioxide Concentration ( Co2 ) < 30 Ppm Langelier Saturation Index ( Lsi ) < 0.3 Fouling Index ( Fi5 ) Or Silt Density Index ( Sdi ) = 7 ( * ) Total Organic Carbon ( Toc ) < 1 Ppm Free Chlorine < 1.5 Ppm Typical Water Quality Measures With A Well-Designed And Maintained Distribution Loop Of 20 Meters: Flow Rate Pressure 5 Lpm / 1.32 Gpm 2.2 Bar / 32 Psi 15 Lpm / 3.96 Gpm 1.9 Bar / 28 Psi20 Lpm / 5.28 Gpm 1.6 Bar / 23 Psi Plumbing Connections Inlet ( Feed Water Connection ) 3 / 4 Bsp Loop Start / Return 1 1 / 2 Sanitary Tc Drains 3 / 8” Lab Water Purification Systems - Type 2 ( Pure ) , Muffle Furnace : Controller: Should Be Microprocessor Based & At Least 8 Segment Programmable Or Equivalent Controller With Necessary Safety Features. Programmable Temperature ( Pid Controller ) Controller With Heating Rate Control From 10?C / Min To 40?C / Min. ( Fast Heating Rate Would Be Preferable ) , Heating Element :Kanthal A1 And Backed By High Temperature Ceramic Insulation , Safety: Over Temperature Protection& Over Load Protection ( Safety Controller ) Should Provided. Door Safety Switch Must Be Provided So That It Disconnects Power Supply To Heating Element When Door Opens. Should Be Equipped With Digital Over Temperature Protection Circuit To Fail Safe In The Event Of A Controller Malfunction , Critical Electronics Component And Heating Elements Protected By A 35A Circuit Breaker., Weight : Less Than 100 Kg , Two Set Of Operation And Maintenance Manual Should Provided. , Ph Meter : Supply Of Bench Top, Digital Ph Meter Along With All Its Accessories And Spares Required Brand Name And Model Name Must Come In The Display. To Operate The Instrument As Per Specification Given Below: The Direct Reading Laboratory Ph Meter ( Digital ) Operable At 230V + / - 10V A.C., 50 Hz Powersupply With Necessary Cable Connections And Other Standard Accessories Required For Smoothoperation. Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2, Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Compensation : It Should Have Both Automatic And Manual Temperaturecompensation Touch Screen Display , Parameters Likeph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level.Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter. Storage Of Instrument : It Should Be Able To Stored In Temperature Of 5 To 40 °C And Relative Humidity Of 5 To 80% ( Non-Condensing ) Glp Compliance : It Should Be Glp Complied .To Improve The Reproducibility, It Should Allow To Choose From At Least Three Endpoint Criteriaaccording To Our Requirements.The Electrode Holder Should Move In A Perfectly Vertical Way, Making It Easy To Place The Sensor In The Perfect Position I.E. Vertically In The Measurement Beaker. It Should Be Able To Connect Peripherals Via Usb And Rs232, Increasing Its Possibilitiessignificantly. Export Of Measurement Data And Calibration Data Should Be Possible To Usb Stickto Direct Pc Software Whenever Required By Us. It Should Allow Monitoring Of Limits Of Parameter Ph By Giving A Warning Message When The Value Falls Below Or Exceeds The Predefined Limits. It Should Have Facility Not To Delete Of Data And Changing Of Settings In Routine Mode. Hence It Required To Be Pin Protected For Login, Deletion Of Data, System Settings Etc. It Should Have Choice Of Endpoint Formats Like Automatic, Manual And Timed. It Should Have Choice Of Ph Decimal Places Like X.Y, X.Yy & X.Yyy ( Up To One, Two Andthree Decimal Places. ) It Should Have Data Storage Up To 1000 Measurements ( Min. ) It Should Have Ph Sensor Input Through Bnc Connector With Impedance Of More Than 3 X 1012O . It Should Have Temperature Sensor Input. It Should Be Able To Show The Quality Of Last Calibration On Its Screen. , Precision Drier : Capacity, Material And Construction: Cap:3Ltr / H Evaporation Rate. Suitable For Aqueous Feed Solution. Laboratory Scale Model. External Body –Ss316. Drying Chamber And Cyclone In Full Ss 316L Construction. Total Construct Size: 1200 X 1300 X 2000 Mm ( ±10% Dimesional Tolerance ) , Self-Supported On Castor / Wheels ( Compressor Size Is Extra ) . Weight: Max 130 Kg ( ±20% ) ( Compressor Weight Is Extra ) Chamber: Chamber Size: Diameter-280-350Mm, Length- 600-1000 Mm, With Conical Bottom. Feed Pump: Variable Speed Gearless Peristaltic Pump With Dual Teflon Rollers And Precise Speed Control. Feed Pump Should Be Of Repute Make Preferable Watson Marlow / Miclin / Flowtec Or Equivalent. Silicon Tube For Feed. Pump Should Be Controlled Through Plc And Manually As Well. Spray System And Nozzle:Moc For Two-Fluid Spray Nozzle: 316L Variable Aperture Nozzle Of 0.7Mm.Other Sizes Such As 0.5 / 1.0 / 1.2 / 1.5 / 2.0 / 2.5 Mm May Be Available. Auto De-Blocking System For Spray Nozzle Which Will Be Fitted On Nozzle Controlled Through A De-Blocker Timer. An Additional Spray Aperture For Future Use Should Be Included. Nozzle Geometry And Design Must Be Submitted With A Tender Document. Desired Output Particle Size Range 20-45 Micron, Compatible With Ceramic Slurry Also. Controller And Display: Plc Based Operating System With A Multi-Touch Colour, Interface, 9” Hmi With Data Logging, Online Trends, Recipe Functionand Ability To Store Recipes And Recall For Ease Of Use. Plc Of Repute Make Such As Siemens, Delta Or Equivalent Etc. Thesystem Should Have An Audio Visual Alarm For A. Inlet Temperature, Outlet Temperature And Atomization Pressure. Thesystem Should Have Parameter Control And Safety Interlock. Inlet / Input Air Temperature / / Temperature Range: Ambient To Minimum 260 Degrees C, Variable And Selectable Aspirator Airflow:Max. 150 Cum 3 / Hr With Vfd For Motor Control Of Repute Make Such As Delta, Fuji Or Equivalent Air Heater:Electrical Heater With Minimum 6.0Kw Capacity Inlet Filter:Combination Type ( Pre + Hepa ) For Pre-Filtering Environment Air To Keep Most Impurities And Particles Away From The Spray Drying Process, Outer Filter Assembly: Mainly To Protect Aspirators From Fine Particles. It Should Include Spun Bound Polyester Cartridge With Ptfe Coating. Efficiency- 1Micron Down To 99.99%.Compressor: Oil-Free Air Compressor Piston Type With Min. 20L Air Reservoir 1Hp Power Supply: Single-Phase, Compatible With Indian Standard , Quartzdouble Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-4.4 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Double Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -2 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified.Primary Boiler Provided With O Ring Accessories Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual , Quartz Single Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-2.2 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Single Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -1 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified. Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual Cut Off Switches Off The Heater Even When There Is No Cooling Water Supply To The Condenser. , Refrigerator : Frost Free Refrigerator : Auto Defrost Function To Prevent Ice-Build Up Capacity 253 Ltrs : Suitable For Small Families And Bachelors | Freezer Capacity: 69 Ltrs Fresh Food Capacity: 184 Ltrs Digital Inverter Compressor – Enjoy Greater Energy Efficiency, Less Noise And A Long-Lasting Performance. It Automatically Adjusts Its Speed In Response To Cooling Demand Shelf Type: Spill Proof Toughened Glass Shelves With Easy Slide Special Features: Easy Slide Shelf, Door Alarm, Inverter, Temperature Control, Cool Pack, Stabilizer Free Operation ( 100 ~ 300 V ) Key Feature : All Round Cooling For Even Cooling Corner To Corner | Power Cool - Enjoy Rapid Cooling Performance | Moistfresh Zone - Preserve The Freshness And Flavor Of Fruit And Vegetables For Longer | Interior Led Light | Moveable Ice Maker | Tall Bottle Guards | Recess Door Handle | Fresh Room | Deodorizer | R600a Refrigerant , Refrigerator-Temperature Control : The Upright Freezer Type Comes With An Abs Make Interior. Its Outer Body Is A Painted Steel Board, The Door Comes With A Handle And A Safety Lock On It, There Are Casters Provided For Easy Handing, Its Inner Drawers Are Made Of Plastic Control System : Uses A Microprocessor-Based Temperature Controller • The Temperature Control Range Is Adjustable Between -10°C To -20°C • It Has A Digital Temperature Display, Equipped With Audio Such As: High Or Low Temperature Alarm, Chamber Volume 270Ltr, Chamber Dimensions 800X500x500 Outer Dimension 1060X695x792 Input Voltage 230Vac 50Hz , Semi-Automatic Nitrogen Protein Analyzer : Analyzer Should Be Semiautomatic System Consisting Of A Digestion Unit, A Scrubber Unit, And A Distillation Unit. Digestion Unit: Automated With Integrated Programmable Control, Should Have Electrically Heated ( 230 ± 10 Volts, 50 Hz Ac ) Metal Blocks. It Should Be Capable Of Providing A Temperature Range From 100°C - 440°C With ±10°C Repeatability. Should Have Inbuilt Temperature Controller With Digital Display And Led Display Along-With Manual Temperature Adjustment. Heating Time Setting With Steps From 1- 150 Minutes Should Have The Capacity To Accommodate At Least Eight Numbers Of Digestion Tubes Each Of At Least 250Ml Capacity , Should Have Leak Proof Integrated Condensers ( Fumes Carriers ) Made Up Of Glass, Fixed On A Movable Panel Along With Adopter For Outlet To The Scrubber Unit. Proper Digestion Exhausts System. Scrubber Unit Should Be An Oil Free Centrifugal Suction Type, With Manual Vacuum Adjustment Facility. Corrosion And Impact Resistant Provided With Condensate And Acid Fumes Collection Vessels. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Distillation Unit Fully Programmable Distillation Unit Including Sample Dilution, Alkali And Receiver Addition, Distillation And Tube Draining Facility. Validated Procedure / Certification For Tkn Distillation Like Aoac, Epa, Din, Iso Etc, Should Be Made-Up Of Standard Quality Borosilicate Glass. Should Possess A Steam Generator Made-Up Of Borosilicate Glass Along With Heater And Have 3 Step Manual Control Facility I.E. Standby, Water Inlet And Distillation. Should Have Inbuilt Bellows Pump For Accurate Reagent ( Alkali / Acid ) Dispensing. Should Have Ventilation Valve. Should Have Timer For 5 - 15 Minutes With Audio Signal. Steam Inlet Tube Should Be Of Ptfe. Unit Should Have Quick Clamping Device For Digestion Tube With Adaptor. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Complete Unit Shouldprovided With One Set Of Digestion Tubes Along-With The Servicing, Operating And Maintenance Manuals. Can Able To Monitor And Measurement Of Distillate Temperature. Self Adjusting Cooling Water Control Facility Safe Feature For Safe Distillation. Can Be Upgradeable Whenever Required Accessories: 2 Set Of Digestion Tubes, Digestion Tube Stand, Spillage Tray For The Condensers, Tube Removing Device , Soxhlet’S Apparatus : Body Constructed In Ms Epoxy Coated Finish , Featuring Use Of Mantle Type Heaters That Comes With Support Of Energy Regulator, Capability To Handle 6 Tests, Can Handle Flasks Of 250Ml Capacity, Supplied Withsupport Of Clamps As Well As Rubber Tubing, Works On Electric Supply Of 220 / 230 Volts, 50 / 60 Hz Ac, Suitable To Heat Soxhlet Flasks Of 250Ml , Top Loading Balance: Maximum Capacity ( Or ) Range Of The Balance80-90 / 220 Gm Readability 0.01 Mg ( 0.00001 Gm ) / 0.1 Mg ( 0.0001 Gm ) Tarring Range 0 – 220 Gm Display Backlit Graphics Display / Lcd With Touch Screen Operation. Repeatability ( Standard Deviation ) 0.03 Mg ( Small Range ) / 0.10 Mg ( Large Range ) , Linearity ±0.20 Mg / ±0.10 Mg, Eccentric Load 0.30 Mg, Calibration Adjustment With Internal Weights, Fully Automatic Calibration Technology With Temperature Controlled, Data Memory Function For Keeping Weighing Data & Calibration History Data, 10 Sensitivity Drift ±2Ppm / °C ( When Automatic Self Calibration Is Not Used ) Stabilization ( Typical And Fast ) Approx. 4.0 Sec ( 0.1Mg ) / 15 Sec ( 0.01Mg ) , Size Of Weighing Pan ~ 80 - 90 Mm, Shielding Glass Draft Shield With Flexible Configuration Protective Cover For The Terminal, Replaceable Feed Through For Weighing Below The Balance, Power Supply To Be Operable With 230 V Ac, 50 Hz Power Supply. Accessories Power Supply Cable With All Accessories For Operation, Operating & Service Manual 2 Sets ( Of Hard Copies ) With Calibration Certificate Of The Balance. Soft Copy Of Instrument Operating Manual To Be Sent During The Time Of Installation, Interface Standard Bi-Directional Rs-232 Interface, Dust Cover One. , Ups For The Laboratory : 10Kva - 192V-8Kw Online Ups , 16Nos External Battery Module With Iron Rack, Ups / Automatic Bypass Facility, True Double-Conversion Online Ups, Microprocessor Control For Higher Reliability. Pure Sine Wave.Input Power Factor Correction. Wide Input Voltage Range ( 110 V – 300 V ) . Generator Compatible, Selectable Charging Current - Allows Flexibility To Add Any Battery Size, Emergency Power Off , Uv-Visible Spectrophotometer : Double Beam ( 185-1100Nm ) Spectrophotometer With Standalone Colour Lcd Display With Pc Controlling Software -Optical System: Double Beam, Diffraction Grating -Minimum 1800 Lines / Mm, Scan Speed :6000Nm / Min, 8 Position Sample Holder, Photometric Details Range Must Cover From -4 To + 4, Bandwidth Variable ( 0.2Nm -6Nm ) Stray Light < 0.05% T @ 220, 340 ( Must Cover Less Than 370Nm ) , Baseline Flatness Must Cover +- 0.006A, Detector- Photodiode / Single Photodiodes / Dual Silicon Photodiodes, Power 240+- 10%, 50-60 Hz, Light Source- Xenon Flash Lamp, Wavelength Details-, Accuracy- Must Cover 1.0Nm, Measuring Modes- Absorbance, Transmittance ( % ) , Concentration, Operating Modes: Single Wavelength, Multiple Wavelength, Time Scan, Data Presentation- Display Analysis Results And Graphic Data On Screen, Pc Link Software, Port To Data Transfer, Supplier Should Provide Service For Installation, Demonstration, Training For All Operation Procedure, Temperature Range- Operating Conditions Should Cover +10 Degree C To 40 Degree, Analytical Quality Assurance- Instrument Should Have Internal Quality Assurance Tools, Certification- Must Comply Ce Certificate. Accessories: Quartz Cuvettes: 50Mm Length, 10Mm, 20Mm Path Length ( Each 2 Pairs ) , Original Catalogue To Be Enclosed. Dedicated Branded Pc To Be Quoted With The System .Should Have Manufacturer’S Service Centre In West Bengal And Details Location To Be Mentioned In The Quotation.. , Vertical Autoclave : Quality Systems For Medical Devices Built: • Floor Standing Vertical Type Top Loading Autoclave • Outer Dimensions: Width 75-87 Cm; Height 90-110 Cm; Depth 65-80 Cm Software Control:• Fully Microprocessor Based Proportional Integral Differential ( Pid ) Pressure Control• Controller And Software Should Comply With International Standards Such As 21 Cfr Part 11 Or Any Other Equivalent.• Should Have Facility To Store Identification Codes And Password Codes For Access Level Control• Built –In Memory To Store Number Of Cycles Sensors:• Should Have In-Built Platinum Resistance Temperature Detector With A Typical Resistance Of 100 O At 0°C That Complies With International Standards Of Safety Requirements For Electric Equipment For Measurement Control And Laboratory Use, Eg. Iec61010-1, Iec 61010- 2-040 • Option To Connect Additional Temperature Sensors And Pressure Sensors Should Be Available Display:• User Interface Should: • Be Easy To Operate• Have Digital Display Enabling Visualization Of Stage Of The Cycle, Set And Process Temperature, Pressure And Quick Access To Important Information • Preferably Have Graphical Display Of Temperature And Pressure• Have Notification For Replacement Of Filters After Appropriate Number Of Runs Performed. Chamber Volume: Should Be Not Less Than 100 Litres And Preferably Should Be 150-180 Litres In Capacity. Suitable Number Of Basket For Bottle, Vessels Or Agar Media Preparation Should Be Quoted Along With The Instrument.Chamber Material: Should Be Long Lasting, Made Up Of 316Ti Grade Stainless Steel Of Asme / Ul Grade Chamber Pressure: Chamber Should Be Designed To Withstand At Least 2.8Bar / 142°C And Should Meet, European Pressure Equipment Directive ( Ped 97 / 23 / Ec ) .2 | 2 Chamber Heating: Should Be Heated Uniformly By A Heating Plate On The Outer Wall With Heater Of Suitable Wattage For Quick Heating.Chamber Insulation: Chamber Should Be Completely Insulated With Chloride Free Glass Wool. Sterilization Temperature Range: 105°C To 137°C With Accuracy Of ± 0.1 Deg C At 121 Deg C & An Additional Isothermal Temperature Range Of 60°C To 105°C. Should Have Feature Minimizes The Time Liquids Are Exposed To High Temperatures During Sterilization Thereby Protecting Liquid Media, Saving Laboratory Time And Reducing Energy Consumption. Biohazard And Waste Management System: Should Have The Facility To Filter Air Removed From Chamber Before Sterilization That Isuseful For Sterilization Of Biohazard Waste.Safety: • Water Level Monitoring And Maintenance Of Constant Level For Safety Of Heaters. • A Safety Device To Prevent Opening The Door When The Chamber Is Pressurized. • Prevent Starting Of Runs If Doors Are Improperly Locked.• Safety Feature Should Allow Opening Of Doors Only When The Temperature Reaches A Pre-Set Temperature And Pressure Reaches Atmospheric Pressure.Power Requirement: A Suitable Size Of Electrical Switch Gear 3 Phase 440 Volt With Earthing Andrecommended Size Of Current Capacity Mccb Will Be Made Available On Wall At Appropriate Place. Other Connection And Installation Has To Be Done By The Supplier. , Hydrometer , Keen Boxes , Aluminium Box , Brass Sieve , Mortar And Pestle , Different Types Of Augers: , Screw Type , Post Hole Type , Dutch Type , Stirrera. Magnetic B. Electric , Khurpi , Electric Heater , Room Thermometer , Gps Machine , Camera , Lcd Projector
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 28
West Bengal View Result →
38.
Drinking Water Supply and Sanitation #8792696 Technical Bid
Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam - 1 Providing, Fixing, Testing & Commissioning Electro Digital Water Level Recorder ( Laser Technology With Sms Facility ) Tag To Server Installed At Dam Safety Office, Bhubaneswar With Following Instruments And Structures For Level And Storage Measurement In Reservoir And Opening Depth / Discharge Measurements From Telengiri Dam, Providing Training To The Field Staff Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 2 M.S. Structure: - Providing, Fabricating & Fixing M.S. Structure Of Required Length To Suit The Site Protected From Reservoir At Top Of The Dam, Made Of 50 Mm X 50 Mm X 6 Mm M.S. Angle Frame Fixed At Dam Front And At Every 0.5 Meter Distance, Fitting In Power Fastener, Painting With Three Coats Of Epoxy Anticorrosive Paint Including Providing & Fixing Pvc Pipe Of 6 Diameter As Per Site Condition From Dam Fsl To Required Lowest Level Of Water Etc; All Complete As Directed By The Engineer-In-Charge. 3 M.S. Platform: - Providing, Fabricating & Fixing M.S. Platform Of Size 1.25 Meter X 1.25 Meter, Fixed In Power Fasteners, Painting With Two Coats Of Epoxy Paint, M.S. Chequered Sheet For Base Plate Including Installation Of Frp Cabinet And Laser Unit Box, M.S. Railing From Three Sides Etc; All Complete As Directed By The Engineer-In-Charge. N 4 Electroray Unit:- Providing & Fixing Electroray Unit With Laser Beam Mounted On M.S. Plate, Provision For Adjustment In Both Axis, Foundation Frame Of 40 Mm X 6 Mm Strip Foundation Bolts, Frp Float For Buoyantly Thrust, Powder Coating, Electronic Sensor Holding Mechanism Mounted In Base Plate And Covered With Frp Security Plate And Security Box With Key & Lock Arrangement, Capacity Measurement For Water Head Zero To 100 Meters Etc; All Complete As Directed By The Engineer-In-Charge. 5 Programme Unit:- Supply Of Data Storage Unit Built In Ip 65 Cabinet From Environment Protection With 64 Kbe2 From Data Storage Memory, Transfer Port With Electronic Cartridge [ Dongle ] For Powerless Automatic Data Transmission And / Or Instant Data Transmission [ Like Blue Tooth ] , 6V Lithium-Ion Battery For Life More Than 15 Months, Two Lines Display, Time Stamping At Ten Different Modes, Maxim Rs 485 / 422 Line Drivers With High Esd Protection For Rs 485 / 422 Communications, Microcontroller Internal 13 Bit Khz Watch Crystal, Two Lines Lcd Display On Mains Supply, Wireless Data Transmission Port Etc; All Complete As Directed By The Engineer-In-Charge. 6 Frp Cabinet:- Supply And Installation Of Fiberglass Reinforced Plastic ( Frp ) Cabin Of Size 1.20 Meter X 1.20 Meter X 2.10 Meter, Both Side Finish, One Side Door And Sliding Aluminum Windows, Frp Roof At Top Of Cabin, Installation On M.S. Platform Etc; Complete As Directed By The Engineer-In-Charge. 7 Software :- Supply Of Dl-Meter Software ( Version 2.0 ) & Loading On Computer For Following Analysis: A )      Log-In Operation B )     Administration Menu C )      System Information About Name Of Govt., Organization, Office, Place, Signing Authority Etc. D )     Master Menu Content For Relative Head E )      Measuring Station Configurations About Ms Code, Consumer Code, Name, Jurisdiction, Location, Sample, Interval Etc. F )      View Station Settings G )     Transactions For Data Capture, Head Content Table Etc. H )      Reports For List Of Measuring Station, Authorized Users, Daily / Fortnightly / Monthly Schedule Time Interval History Etc. I )       Charts Numerical And Graphical For Monthly / Yearly Head / Content Consumption Distribution Etc. J )       Help For Operation And Maintenance Of System. 8 Fixing & Commissioning Of Dl-Meter Unit And Programme Unit On Pvc Pipe, Foundation Template, Nut-Bolts And Cabinet In Line & Level Completed Item As Directed By The Engineer-In-Charge. 9 Testing & Training For Dl-Meter To Field Staff And Operator For Handling Troubleshooting, Data Transmission, Software Operation Etc; Complete As Directed By The Engineer-In-Charge. 10 Providing And Fixing Fencing To Recorder Cabin For Extra Protection Including 50 Mm X 50 Mm X 6 Mm M.S. Angle Structure Covered With M.S. Mesh Of Size 2.5 Cm X 2.5 Cm With Two Coats Of Anticorrosive Epoxy Painting Etc; All Complete As Directed By The Engineer-In-Charge. 11 Inverter :- Supplying, Fixing, Testing And Commissioning Inverter For Power Back Up To Recorder, Luminous Brand 12 V 500 W Capacity Operating On Mains On Solar Energy With Auto On / Off Switch Over With M. S. Bracket Luminous Brand Lithium Battery Of Capacity 150 Ah Lpt 12150 Htt With Power Connection, Battery Stand, Brackets, Wooden Planks & Rubber Sheets, Led Candle Light Of 5 Watt Bulb, Cover With Packing, Forwarding, Transportation And Installation At Site With All Electrical Fittings, Cable, Switches, Plugs For Battery & Inverter, Recorder And Light Including Testing & Training To Field Staff Etc; All Complete As Directed By The Engineer-In-Charge. 12 Providing & Fixing V-Notch ( 15 Ltr. / Sec ) Made Of Glass Fibre Improved “Venturi” Plate Conforming To Is: 9108 For Accurate Measurement Of Water Flowing Through Channels Comprising Of Masonry Construction Provided With Pre-Fabricated Glass Fibre Lining On Both Sides, A Side Chamber Provided In One Side Masonry Wall Of The Said V-Notch On The Upstream Side, A Pipe Provided At The Bottom Of The Chamber Connecting The Said Chamber With The Water Flowing Through The Flume, A Float Means Provided In The Said Chamber, Enabling Recording The Rising Or Falling Level Of Water In The Said Chamber Such As A Scale Provided In The Said Chamber, Moulded Engraved Gauge Marking In Lit / Sec And Also In Centimeter Including Moulded And Engraved Discharge Table, Capacity Marking, Flow Direction, Manufacturer Name And M.S Pipe Stiffeners, Hold Fasts, Sand Treatment On The Backside Of Plate Etc; Complete Including Concrete Foundation 2.0 M ( L ) X 0.50 M ( W ) X 0.15M ( D ) With Verticlal Concrete Wall Behind V-Notch Of Thickness 0.10 M And Transition Wall For Up-Stream & Down-Stream For 25 M Length With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 13 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Molded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Marking Of Reduced Levels, Sill, Fsl, Frl, Mwl Etc; With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 14 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Moulded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Engraved Marking Of Salient Features, Chainages, Numbers And Instructions In Eye Pleasant Colour Combinations As Per Demand For Given Size And Location Including M.S. Frame And Concrete Work With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge ( For Salient Feature Board / Chainage Board / Instruction Board / Data Board Etc. ) 15 Providing, Fixing, Testing And Commissioning Of Vibrating Wire Type Standard Piezometer Of Following Specification To Measure Ground Water Pressure Along With Required Accessories Including Drilling, Boring, Pipe And All Other Statutory Charges Etc; As Per Requirement With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge But Excluding Periodical Read Out Unit & Stop Watch. Specification: *Standard Range : 5-200Ksc *Over Range : 2 X Rated Pressure *Sensitivity : 0.1 % F.S. *Accuracy + / - 0.5 % F.S> * Temp. Range -20ºc To +70º C *Length X Diameter ( 140 Mm X 20 Mm ) / ( 194 Mm X 25.4 Mm ) / ( 140 Mm X 25.4 Mm ) 16 Supplying Periodical Read Out Unit For Piezometer Complete Set With Required Software, Specification And Commissioning With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Vibrating Wire Read Out Box Shall Be Portable Unit Designed For The Read Out Of All Vibrating Wire Gages And Transducers And Shall Be Capable Of Displaying The Reading In Digits, Frequency ( Hz ) , Period ( Us ) , Or Microstrain ( Μ£ ) . The Read Out Shall Also Display The Temperature Of The Transduer ( Embedded Thermistor ) With A Resolution Of 0.1°C. All Readings Shall Be Transmitted To A Host Computer And Imported Into Spread Sheet And Database Applications. Suitable For All Vibrating Wire Pp Meter To Take The Data From Sensors Directly In Engineering Units. The Unit Shall Store 750 Data With Date & Time And With Rs 232 / Rj45 Port ( Wi-Fi Optional ) To Down Load The Data In A Pc. The Unit Shall Be Rechargeable Battery Operated . Specifications : * Excitation Range : 5 Volt Square Wave * Measuring Resolution: 0.5 Ms. * Memorry: 64K Eprom * Reading Storage : 750 Data In Engineering Mode 17 Supplying & Fixing Digital Display Portable Isi Marked Stop Watch With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 18 Supplying & Fixing High Resonance Cc Tv Camera System, Gorilla Type, With 8 Ch 4 K Net Work Video Recorder, 8 Channel Ip Camera Input, H.265 / H.264 Dual Video Formats, Support 4 K Resolution Up To 8 Mp Recording, 80 Mbps Incoming / Outgoing Bandwidth, Support 1Sata Hdds Up To 8Tb, 3Usb Ports, Support Multi-Brand Network Cameras, Mobile Software: Android, Ios, Cms Software : Ivms Etc; With Following Accessories With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge 19 Cp Plus 8 Ch Nvr 2Sata 20 Cp Plus 2 Mp Ip Ptz ( Moving Camera ) 21 Cp Plus 3 Mp Ip Motorised Verry Focal ( Fixed Camera ) 22 8 Port Poe Switch 23 Survilance Hdd 4 Tb 24 Point To Point Antena 25 Cat 6 Cable 26 Rj 45 Clips 27 Metal Box At Each Camera & Antena 28 Power Point At Each Camera 29 Pole At Each Camera 30 Display Unit And Installation Charges 31 Providing, Fixing, Testing, Training And Commissioning Total Weather Station Tag To Server With Sms Facility Installed At Dam Safety Office, Bhubaneswar With Gsm Interface Metrological Station, Imd Approved Monitoring Of Hourly Data Of Temperature, Humidity, Wind Velocity And Rain Gauge Of Data Transfer Through Sms For Ten Mobile Numbers, Gsm Recharge By Department And Memory Card And Tag To Code Analyser. Server With Software, Mounting Tripod 3 Meter, Earthling Kit, Usb Weather Link With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Parameters : In Sms A ) Location, Date, Time B ) Rainfall In Pre-Decided Time And Cumulative Rain Fall C ) Temperature Minimum And Maximum In A Day D ) Relative Humidity Minimum And Maximum In A Day E ) Wind Speed Minimum And Maximum In A Day F ) Wind Direction At Pre-Decided Time 32 Providing & Fixing Joint Meter Of Following Specification With All Required Accessories Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Range: 0 - 50 Mm. B ) Accuracy : + / - 0.5 % Fs. C ) Resolution: 0.05 Mm. D ) Emp Limit: 10 To 70 Deg C. E ) Thermister: Ysi-44005 Or Equivalent. Material: Stainless Steel F ) Materials: Stainless Steel ( To Be Installed Between Block No. 2 & 3; 4 Nos. At Each Block Joint To Monitor The Joint Opening ) 33 Providing & Fixing Ph Meter ( Portable ) 3 1 / 2 Digit Lcd Display In Abs Plastic Body With Touch Switches And Combination Ph Electrode Of Following Salient Features With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Measurers Ph, Mv And Temperature 5 Point Calibration. B ) 16 X 2 Line Alphanumeric Lcd With Backlit. C ) Auto Buffer Recognition Facility. D ) Storage Up To 1000 Samples. E ) Attachment For Centronics Dot Matrix Printer 34 Supply, Installation & Monitoring Of Seismograph Of Following Specification & Parameters From Sl. No. 10.1 To 10.9 Below With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 35 * Performance Tested By University Of Technology Sydney, University Of Melbourne, Ce Certified. * Records Triaxial Data From Integrated Seismometer Continuously To Sd Card Storage. * Fault Detection - Sd Card Full / Error, Power, Temperature * Real-Time Alarm Output To Relay Circuit During Earthquake * Internal Battery Available ( Optional ) . * Designed For Minimum 10 Years Operation. Kelunji Prism Used In Structural Monitoring Have Operated For Over 20 Years, Producing An Aggregate Mtbf Of Greater Than 5 Years 36 Recorder: * Type : 32-Bit Adc * Data Channels : Three, Synchronously Sampled * Full-Scale Signal ( Standard ) 40 Vpp ( Voltas Peak-To-Peak ) * Sensitivity ( Standard ) 419430.4 Counts Per Volt * Preamplifier Gains Available ( User Selectable ) X1, X2, X4, X8, X16, X32, X64, X128, X256. * Frequency Reasonse Dc To 2000 Hz Sampling Rates Available ( Samples Per Second ) 40, 100, 200, 250, 400, 500, 800, 1000, 1600, 2000 37 Sensor: * Type : Velocity * Data Channels : Triaxial ( East-West, North-South, Up-Down ) . * Sensitivity : 868 V / M / S. * Noise Performance Below Nlnm Between 2 And 9 Second Period, Freqency Response 30 Second Period To 80 Hz. 38 Timing: * Reference Time Stamp With Every Pps ( Pulse Per Second ) From Gps Receiver Accuracy: Rms 30 Nano Seconds. 39 Recording: *File Recording Options: Continuous ( Always On ) * Trigger / Alarm: Algorithms Sta / Lta ( Any / All Channels ) , Level ( Any / All Channels ) , System ( Voltage, Memory, Temperature ) . * Storage Memory Type : Sd Card ( Sdhc Or Micro Sd Using Adaptor. Included Storage 32 Gb ) . * Continuous Triaxial Recording Capacity @ 100 Sps Over 1 Year Of Data Stored In A Ring Buffer ( Oldest Data Over Written When Full ) . * File System Format: Fat32, Readable By Windows, Mac & Linux Operating Systems * Data Format: Mini Seed ( With Companion Text Files Containing Station Data ) 40 Power: * Dc Charger Voltage Input Range 10-36 Vdc. * Consumption ( When Recording Continuous Data ) 1.1W * Runtime On Internal 12 V Battery 12 + Hours 41 Physical: * Housing Cnc Milled From Solid Alumimum, Hard Anodized. * Dust And Water Ingression Protection: Ip 67. * Operating Temperature Range ( Up To 100% R / H ) - 20 Deg. C To + 70 Deg. C * Size ( Excluding Connectors ) Ø 135Mm, 225Mm High * Weight ( Standard, With Internal Battery ) 3.1 Kg. 42 User Interface: * Configuraton Interface In-Built Lcd With 4-Line Text Display And 4- Button Input * Data Telemetry Ip Streaming Over Optional Ethernet Adaptor Or 3G Cellular Modem * Remote Set Up And Communications Via Live Stream Application Or Eqserver Web Interface 43 Connectors & Cables: * Power 2 Pin Circular Push / Pull Lock * On-Off Switch : External Push Button * Power Cable 2 M Length With Bare Wire Ends
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
39.
Rural Development #8523125 AOC
Tender For Regarding Supply Of Various Type Of Material /Goods At Grampanchayat Sakhali Bk. Taluka Buldhana District Buldhana , Pvc Cement Solvent / Pvc Solution For Pipe Line Work 1 Ltr , Swing Check Type Reflux (Non-Return) Valves For Water Works Purposes , Pvc Pipe 4Kg 75 Mm , Pvc Pipe 4Kg 90 Mm , Pvc Pipe 4Kg 120 Mm , Pvc Pipe 6Kg 75 Mm , Pvc Pipe 6Kg 90 Mm , Pvc Pipe 6Kg 120 Mm , Elbow For Pipe 4Kg 75 Mm , Elbow For Pipe 4Kg 90 Mm , Elbow For Pipe 4Kg 120 Mm , Coupling For Pipe 4Kg 75 Mm , Coupling For Pipe 4Kg 90 Mm , Coupling For Pipe 4Kg 120 Mm , T For Pipe 4Kg 75 Mm , T For Pipe 4Kg 90 Mm , T For Pipe 4Kg 120 Mm , Elbow For Pipe 6Kg 75 Mm , Elbow For Pipe 6Kg 90 Mm , Elbow For Pipe 6Kg 120 Mm , Coupling For Pipe 6Kg 75 Mm , Coupling For Pipe 6Kg 90 Mm , Coupling For Pipe 6Kg 120 Mm , T For Pipe 6Kg 75 Mm , T For Pipe 6Kg 90 Mm , T For Pipe 6Kg 120 Mm , Ferrule Cock 15 Mm (Brass) , Water Meter Single Jet Isi Mark 15 Mm Class B , Water Meter Double Jet Isi Mark 15 Mm Class B , Swiss Valve For 2.5 Pipe Line , Swiss Valve For 3 Pipe Line , Swiss Valve For 4 Pipe Line , Swiss Valve For 6 Pipe Line , Pvc Pipe Cid Joint For 2.5 Pipe Line , Pvc Pipe Cid Joint For 3 Pipe Line , Pvc Pipe Cid Joint For 4 Pipe Line , Pvc Pipe Cid Joint For 6 Pipe Line , Pvc Pipe Cid Joint Rubber Ring For 2.5 Pipe Line , Pvc Pipe Cid Joint Rubber Ring For 3 Pipe Line , Pvc Pipe Cid Joint Rubber Ring For 4 Pipe Line , Pvc Pipe Cid Joint Rubber Ring For 6 Pipe Line , Resilient Seated Cast Iron Single Air Relief Valves For Water Works Purposes , Resilient Seated Cast Iron Double Air Relief Valves For Water Works Purposes , Pvc Cement Solvent / Pvc Solution For Pipe Line Work 5 Ltr , U-Pvc Pipe 40 Mm , Elbow For U-Pvc Pipe 40 Mm , Coupling For U-Pvc Pipe 40 Mm , T For U- Pvc Pipe 4Kg 40 Mm , Stainless Steel Long Body Bib Cock Tap With Flange 40 Mm , O-Ring For U-Pvc Pipe 40 Mm Plane , Water Tank 4 Layer Food Grade 100 Ltr , Water Tank 4 Layer Food Grade 200 Ltr , Water Tank 4 Layer Food Grade 250 Ltr , Water Tank 4 Layer Food Grade 500 Ltr , Water Tank 4 Layer Food Grade 1000 Ltr , Water Tank 4 Layer Food Grade 1500 Ltr , Water Tank 4 Layer Food Grade 2000 Ltr , Water Tank 4 Layer Food Grade 2500 Ltr , Water Tank 4 Layer Food Grade 3000 Ltr , Water Tank 4 Layer Food Grade 5000 Ltr , Submersible Motor Pump 1 Hp , Submersible Motor Pump 2 Hp , Submersible Motor Pump 3 Hp , Submersible Motor Pump 3Hp Three Phase , Submersible Motor Pump 7.5Hp 5 Stage Three Phase , Submersible Motor Pump 7.5Hp 8 Stage Three Phase , Submersible Motor Pump 7.5Hp 10 Stage Three Phase , Submersible Motor Pump 7.5Hp 12 Stage Three Phase , Submersible Motor Pump 10.5 Hp 5 Stage Three Phase , Submersible Motor Pump 10.5 Hp 8 Stage Three Phase , Submersible Motor Pump 10.5 Hp 12 Stage Three Phase , Submersible Motor Pump 10.5 Hp 20 Stage Three Phase , Centrifugal Monoblock Pump Motor Pump 1 Hp , Centrifugal Monoblock Pump Motor Pump 2 Hp , Centrifugal Monoblock Pump Motor Pump 3 Hp , Centrifugal Monoblock Pump Motor Pump 3Hp Three Phase , Centrifugal Monoblock Pump Motor Pump 5Hp Three Phase , Centrifugal Monoblock Pump Motor Pump 6.5 Hp Three Phase , Centrifugal Monoblock Pump Motor Pump 7Hp Three Phase , Centrifugal Monoblock Pump Motor Pump 7.5 Hp Three Phase , Isi Mark Starter For 5 Hp Submersible Motor Pump , Isi Mark Starter For 12 Hp Motor Pump , Isi Mark Hdpe Pipe Roll For Sub. Pump In Borewell 50Mm X 4Mm X Per Meter , Isi Mark Submersible Cable Diameter 4 Mm Length Per Meter , Isi Mark Submersible Rope Yellow Borewell Submersible Pump Rope,Poly More Virgin And Braided Twisted Cord Twine Rope String (16 Mm,Per Meter Meter) , Auto Switch For Water Moter Starter Upto 12 Hp , Aluminium Armoured Power Cable-50 Sq Mm 3.5 Core , Clorine Dosing Machine Without Stand By System , Clorine Dosing Machine With Inbuilt Stand By System , 11 Ltr Dustbeen Pvc Without Leads , 15 Ltr Dustbeen Pvc Without Leads , 20 Ltr Dustbeen Pvc Without Leads , 35 Ltr Dustbeen Pvc Without Leads , 11 Ltr Dustbeenpvc With Lead , 15 Ltr Dustbeen Pvc With Lead , 20 Ltr Dustbeen Pvc With Lead , 35 Ltr Dustbeen Pvc With Lead , 11 Ltr Dustbeenpvc Swing Bin , 15 Ltr Dustbeen Pvc Swing Bin , 20 Ltr Dustbeen Pvc Swing Bin , 35 Ltr Dustbeen Pvc Swing Bin , 11 Ltr Dustbeenpvc With Pedal , 15 Ltr Dustbeen Pvc With Pedal , 20 Ltr Dustbeen Pvc With Pedal , 35 Ltr Dustbeen Pvc With Pedal , 20 Ltr Twinbin Pedal , 11 Ltr Dustbeensteel With Pedal , 15 Ltr Dustbeen Steel With Pedal , 20 Ltr Dustbeen Steel With Pedal , 30 Ltr Dustbeen Steel With Pedal , Dustbeen Rabbit Shape 10 Ltr , Dustbeen Rabbit Shape 15 Ltr , Dustbeen Rabbit Shape 20 Ltr , Dust Bin Big Double 110 Ltr Pvc With Stand , Dust Bin Big 110 Ltr Pvc , Dust Bin Big 120 Ltr Pvc , Dust Bin Big 100 Ltr Pvc With Wheel , Dust Bin Big 110 Ltr Pvc , Dust Bin Big 120 Ltr Pvc With Wheel , Dust Bin Big 240 Ltr Pvc With Wheel , Green And Blue Garbage Tri-Cyle Rickshaw , E Garbage Hydraulic Garbage E-Cart With Tipping Facility Three Wheeler , E Garbage Hydraulic Garbage E-Cart With Tipping Facility Four Wheeler , Refrigerator For Food Storage 50 Liters - 80 Liters Single Door , Refrigerator For Food Storage 150 Liters - 250 Liters Single Door , Refrigerator For Food Storage 250 Liters - 330 Liters Single Door , Refrigerator For Food Storage 350 Liters - 490 Liters Single Door , Air Condition 1 Ton 3 Star Split Inverter Ac , Air Condition 1.5 Ton 3 Star Split Inverter Ac , Air Condition 2 Ton 3 Star Split Inverter Ac , Air Condition 1 Ton 4 Star Split Inverter Ac , Air Condition 1.5 Ton 4 Star Split Inverter Ac , Air Condition 2 Ton 4 Star Split Inverter Ac , Air Condition 1 Ton 5 Star Split Inverter Ac , Air Condition 1.5 Ton 5 Star Split Inverter Ac , Air Condition 2 Ton 5 Star Split Inverter Ac , Desert Cooler Small , Desert Cooler Medium , Desert Cooler Large , Personal Cooler Small , Personal Cooler Medium , Personal Cooler Large , Led Tv 24 With Hdmi , Led Tv 32 , Smart Led Tv 32 , Android Led Tv 32 , Led Tv 40 , Smart Led Tv 40 , Android Led Tv 40 , Led Tv 42 , Smart Led Tv 42 , Android Led Tv 42 , Led Tv 50 , Smart Led Tv 50 , Android Led Tv 50 , Led Tv 55 , Smart Led Tv 55 , Android Led Tv 55 , Led Tv 75 , Smart Led Tv 75 , Android Led Tv 75 , Wall Mount Kit For Led Tv 24 Inch To 75 Inch , Installation, Labour Charges, Other Charges For All Type Of Tv , Led Screen 19.5 Hd , Lcd/Tft/Led Monitor For Pc - 17 Normal , Lcd/Tft/Led Monitor For Pc - 18 Normal , Lcd/Tft/Led Monitor For Pc - 18 .5 Normal , Lcd/Tft/Led Monitor For Pc - 19 Normal , Led Monitor For Pc - 19 Normal , Led Monitor For Pc - 19 Branded , Led Monitor For Pc - 22 Normal , Led Monitor For Pc - 22 Branded , Led Monitor For Pc - 22 Full Hd Branded , Led Monitor For Pc - 24 Full Hd Branded , Power Cable For Pc 1.5 Mtr , Power Cable For Pc 3 Mtr , Power Cable For Pc 5 Mtr , Power Cable For Pc 10Mtr , Vga Cable 5 Meter For Pc , Vga Cable 10 Meter For Pc , Hdmi Cable 1.5 Meter For Pc , Hdmi Cable 3 Meter For Pc , Hdmi Cable 5 Meter For Pc , Hdmi Cable 10 Meter For Pc , Surge Protector 1.5 Mtr , Surge Protector 3 Mtr , Surge Protector 5 Mtr , Surge Protector 10 Mtr , Aux Audio Cable 10 Mtr For Pc To Speaker , Projector Branded , Projector Un-Branded , Projector Celeing Mount Kit , Projector Screen Size 6X4 , Installation, Labour Charges, Other Charges For Projector , Elerning Syllabus Marathi Software Per Class (1 To 4) , Elerning Syllabus Urdu Software Per Class (1 To 4) , Elerning Syllabus English Software Per Class (1 To 4) , Elerning Syllabus Marathi Software Per Class (5 To 8) , Elerning Syllabus Urdu Software Per Class (5 To 8) , Elerning Syllabus English Software Per Class (5 To 8) , Elerning Syllabus Marathi Software Per Class (9 To 10) , Elerning Syllabus Urdu Software Per Class (9 To 10) , Elerning Syllabus English Software Per Class (9 To 10) , Training Charges For E Learning Software Per Sylabus , Pendrive 8 Gb , Pendrive 16 Gb , Pendrive 32Gb , Pendrive 64 Gb , Pendrive 128 Gb , Pendrive 256 Gb , External Solid State Drives:256 Gb , External Solid State Drives:512 Gb , External Solid State Drives: 1 Tb , External Solid State Drives: 2Tb , Mouse Usb Branded , Mouse Wire Less Branded , Keyboard Usb Branded , Keyboard Mouse Usb Combo Branded , Keyboard Mouse Combo Wire Less Unbranded , Keyboard Mouse Combo Wireless Branded , Speaker / Home Theater 4.1 , Speaker / Home Theater 5.1 , Trolley Spekar 12 Woofer Bt/Usb/Sd/Fm/2 Wireless Mike , Trolley Spekar 18 Woofer Bt/Usb/Sd/Fm/2 Wireless Mike , Trolley Spekar 8X2 Woofer Bt/Usb/Sd/Fm/2 Wireless Mike Option For Two 6.35Mm Port For Mic And Tws Mode , Trolley Spekar 10X2 Woofer Bt/Usb/Sd/Fm/2 Wireless Mike Option For Two 6.35Mm Port For Mic And Tws Mode , All In One Printer (Inkjet Technology Monochrome) With Adf , All In One Printer Lejer Jet All In One , Printer All In One [Print / Scan / Copy] Mini Xerox Machine , Printer All In One [Print / Scan / Copy] Colour-Ink Jet , Printer Only For Print Laserjet Monochrome , Printer Only For Print Inkjet Monochrome , Colour Printer Only For Print Inkjet , Computer System [C2d/2Gb/500Gb Hdd] , Computer System (C2d/2Gb/1Tb Hdd) , Computer System [Ci3 8 Gen 4Gb Ram,1Tb Hdd,20 Screen, ,Keyboard,Mouse] Branded , Computer System [Ci3 9 Gen 4Gb Ram,1Tb Hdd,20 Screen, Keyboard,Mouse] Branded , Computer System [Ci3 10 Gen 4Gb Ram,1Tb Hdd,20 Screen, Keyboard,Mouse] Branded , Computer System [Ci3 8 Gen 8Gb Ram,1Tb Hdd,20 Screen, ,Keyboard,Mouse] Branded , Computer System [Ci3 9 Gen 8Gb Ram,1Tb Hdd,20 Screen, Keyboard,Mouse] Branded , Computer System [Ci3 10 Gen 8Gb Ram,1Tb Hdd,20 Screen, Keyboard,Mouse] Branded , All In One Pc (Ryzen 3 Dual Core 4 Gb Ddr4/1 Tb/Windows 10 Home/23.8 Inch Screen) , All In One Pc (Intel Pentium Core/ 4 Gb Ddr4/1 Tb/Windows 10 Home/23.8 Inch Screen) , All In One Computer Systembranded[Core I3,4Gb Ram,1Tb Hdd,,19To 24 Led] , All In One Computer System Branded[Core I5,4Gb Ram,1Tb Hdd,19 To 24 Led, Dos Wifi,Web Cam,Keyboard,Mouse] ] , All In One Computer System Branded[Core I3,4Gb Ram,1Tb Hdd,,19 To 22 Led, Dos Wifi,Web Cam,Keyboard,Mouse] ] , All In One Computer Systembranded[Core I5,8Gb Ram,128 Ssd, 1Tb Hdd,,27 Led,Windows 10 Wifi,Web Cam,Keyboard,Mouse] , All In One Computer Systembranded[Core I5,8Gb Ram,1Tb Ssd,,27 Led,Windows 10 Wifi,Web Cam,Keyboard,Mouse] ] , Ups For Computer System , Dvr 16Ch + 1Ip 2.4Mp , Dvr 16Ch [5 Mp Supported 2Ip Camera Supported] , Dvr 8Ch 2.4Mp Supported , Nvr 8 Ch([5 Mp Supported Ip Camera Supported] , Nvr16 Ch([5 Mp Supported Ip Camera Supported] , Surveillance Internal Hard Drive 4Tb , Surveillance Internal Hard Drive 2Tb , Surveillance Internal Hard Drive 1Tb , Dome Camera 2.4Mp , Bullet Camera 2.4Mp , Dome Camera 2.4Mp Ip Cam , Bullet Camera 2.4Mp Ip Cam , Bnc Connector , Power Connector , Power Supply 20Amp , Cctv Cable Bundle , Ip Camera 2.4 Mp , Poe Switch For 8 Ch , Poe Switch For 16 Ch , Poe Splitter For Ip Camera , Cat6 Cable Per Mtr , Pipe 10Ft Unit For Cctv Setup , Iron Wire In Kg (Min 300Ft) , Hook Packet , Labour Charges For Feeting Of Cctv Equipements , Ceiling Mount Kit For Cctv , Hevy Chairs For Kids , Baby /Kids Chair , Computer Wheel Chair , S Type Chair Non-Revolving And Non-Tilting Chair With Armrest , Office Chair Full Back Wheel , Office Chair Half Back Wheel , Office Chair Mid Back Wheel , Portable Foldable Wheelchairs For Handicap , Fiber Chair , Fibre Chair With Cushion Normal , Round Table With Chair Set , Three Seatervisitor Bench-Metal , Cement Bench For Park , Iron Patient Hospital Basic Examination Table , Wooden School Benches And Desks, Seating Capacity: Double 01 To 04 , Wooden School Benches And Desks, Seating Capacity: Double 5 To 8 , Wooden School Benches And Desks, Seating Capacity: Double 9 To 12 , Office Table 3X6 Feet , Office Table 2.5X5 Feet , Office Table 2X4 Feet , Office Table 2X3 Feet , Office Table Executive , Table Top Glass Thickness 12Mm Sqr Per Feet , Table Top Cloth( Velvet Quilted Cloth, Gsm 150) Per Meter , Table Name Plate( Clear Acrylic 2-Sided V-Shaped Desktop Sign Display Stand Name Plate 2 X 8 Inch) , Office Cupboard 6.5 Feet Steel/Iron , Office Cupboard 5.5 Feet Iron , Office Cupboard 4.5 Feet /Iron , Office Cupboard 6.5Ft With Locker , Industrial Locker Steel Almirah - 8 Locker Number Of Compartments , Book Rack4 Shelves Paint Coated Iron Almirah Bookshelf , Basics Storage Rack 7 Shelf 118X12x36 Inch Udl , Basics Storage Rack 6 Shelf 118X12x36 Inch Udl , Basics Storage Rack 5 Shelf 118X12x36 Inch Udl , Basics Storage Rack 4 Shelf 118X12x36 Inch Udl , Celeing Fan 1200 Mm , Table Fan 16 Inch , Pedestal Fan 16 Inch , Wall Mount Fan 400 Mm , Steel Bucket 10 Ltr , Steel Bucket 15 Ltr , Steel Bucket 20 Ltr , Fiber Bucket 10 Ltr , Fiber Bucket 15 Ltr , Fiber Bucket 20 Ltr , Permenant Marker Pen Box 10 Nos , Sticky Notes Paper Flag 15Mm X 76Mm Multicolour , Stapler Big Size Half Strip All Metal , Stapler Pin Big Pin Size 24/6 Pin Box , Stapler Medium Size Half Strip All Metal , Regular Pin 10 No Not Stapler Pins Box , Paper Punching Machine Small Size , Paper Punching Machine Medium Size , Paper Punching Machine Big Size , Ice Pick(Tocha) , A4 Size Paper Rim Single Psc 65 To 70 Gsm , Legal Size Paper Rim Single Psc 65 To 70 Gsm , Stamp Pad,110 X 69 Mm Small , Stamp Pad 155 X95 Mm Large , Stamp Ink Bottel 25 Ml Voilet/Red/Black , Butter Flow Ball Pen Single Pcs , Gripper Pen Single Pcs , Acrylic Name Plate Size 10X24 Inch , Acrylic Name Plate Size 60X90 Inch , Calculator 112 Step Check And Correct 12 Digit , Glass Paper Weights (Set Of 1, Multicolor) , Cotton Paper Tag, Red Advocate Paper Tie Tags 50 Pieces , File Cotton Laces, (22 Inch Long Each,50 Piece) , Plane Register 1 Quire Set On 1 Piece , Plane Register 2 Quire Set On 1 Piece , Plane Register 3 Quire Set On 1 Piece , Plane Register 4 Quire Set On 1 Piece , Spring File - Fullscape, Multicolour,(Normal File) 1 Piece , Tep Finest Paper File Record File (High Quality File) 1 Piece , Cardboard Box Files 1 Piece , Head Pins Fine Satin Pin Craft Single Box 100 Pcs , Glue Stick 5G , Glue Stick 15G , Gum - Lime 50 , Paste Gum Bottle 100Ml , Paste Gum Bottle 200Ml , Gum - Lime, 200Ml Bottle , Paste Gum Bottle 300Ml , R O Can 20 Ltr , Ro 12 Ltr With Storage Tank With Feetings And Nessesory Parts , Ro 15 Ltr With Storage Tank With Feetings And Nessesory Parts , Ro 25 Ltr With Feetings And Nessesory Parts , Water Cooler 60 Ltr With Two Tap Capasity , Water Cooler 80 Ltr With Two Tap Capasity , Water Cooler 120 Ltr With Two Tap Capasity , Curtnes Per Sq Mtr , Carpate Per Sqr Ft As Per Requirement , Chappal / Shoes Stand , Mat For School Kids 26 Pcs Set , Satranji 10X20 , Satranji 10X15 , Satranji 6X9 , Printed Plastic Floor Mat, Mat Size: 6 X 9 Feet , Bhojan Patti 1.5X 6 Floor Mat , 36 Pieces Alphabet & Number Floor Mats , Mirror Plastic Frame Mirror , Led Light 15 Watt , Led Light 18 Watt , Led Light 20 Watt , Pendent Lam Holder , Led Tubelight - 20W , Led Street Light 40 Watt , Led Street Light 30 Watt , Led Street Light 25 Watt , L Shape Pipe For Led Street Light , Clamp For L Shape Pipe Streetlight And Pole , All In One 9W Solar Street Light With Pole And Installation , All In One 15W Solar Street Light With Pole And Installation , All In One 18W Solar Street Light With Pole And Installation , All In One 25W Solar Street Light With Pole And Installation , All In One 25W Solar Street Light With Decorative Pole With Simple Light And Installation , All In One 25W Solar Street Light With Decorative Pole With Round Shape Of Single Arm And Light With Installation , All In One 25W Solar Street Light With Decorative Pole With Round Shape Of Two Arm And Light With Installation , Wire 1.5 Sq Mm Black Fr Pvc Housing Length 90 Mtr , Wire 2 Sq Mm Black Fr Pvc Housing Length 90 Mtr , Wire 2.5 Sq Mm Black Fr Pvc Housing Length 90 Mtr , Solar Polycrystalline Off-Grid Solar Photovoltaic (Pv) Power Plant, Capacity 1 Kva With Installation , Solar Polycrystalline Off-Grid Solar Photovoltaic (Pv) Power Plant, Capacity 2 Kva With Installation , Solar Polycrystalline Off-Grid Solar Photovoltaic (Pv) Power Plant, Capacity3 Kva With Installation , Grid Connected Rooftop Solar System 1Kw Solar System With Installation And Other Charges Are Included , Grid Connected Rooftop Solar System 2 Kw Solar System With Installation And Other Charges Are Included , Grid Connected Rooftop Solar System 3 Kw Solar System With Installation And Other Charges Are Included , Grid Connected Rooftop Solar System 5 Kw Solar System With Installation And Other Charges Are Included , Solar Unit Complete Set With Installation For Anganwadi/School [Fan X 1, Led Bulb X 1 With Fitting & Installation] , Solar Unit Complete Set With Installation For School/Anganwadi/ Office [1 Computer, Fan,2Light,] , Solar Unit Complete Set With Installation [ Fan X 4, Pc X 1, Light X 4, 1Hr Backup With Fitting & Installation]] , Solar Hi Mast Complete 1 Set Of 20 Watt , 50W Spv Solar Combo Including 12V/40Ah Artheon Battery With Installation , Solar Pump 7.5 Hp With All Accessories, Solar Mono Pv Panels And Installation , Inverter 1225 (12V) For Office Ups, Assorted, Standard Isi Mark , Isi Mark Inverter Tubular Battry , Fogging Machine Branded Single Blor , Fogging Machine Un-Branded Single Blor , Sanitary Pad Vending Machine , Sanitary Pad Disposal , Sanitary Pad Product Dimensions: ?21 X 7.3 X 13 Cm Per Nos , Sanitary Pad Extra Long ?Product Dimensions ?23.5 X 9.2 X 13 Cm Per Nos , Custome Face Mask , 3 Ply Face Mask , Ppe Kit , Plastic First Aid Kit With Medicines , Steel/Metal First Aid Kit With Medicines , Baby Rediant Heat Warmar , Stethoscope , Human Body Weight Machine Digital , Baby Weighting Machine Digital , Baby Weight Slater , Digital Infrared Thermometer Gun , Digital Thermometer , Finger Tip Puls Oximeter , Fully Automatic Digital Blood Pressure Monitor , Analog Blood Pressure Monitor , All In One Steam Vaporizer Machine , Hemoglobin Digital Monitor , Sterile Surgical Glove 6-Inch Pre-Powdered-Box Of 50 Pairs , Compressor Nebulizer , Blood Glucose Monitor , 25 Test Strips Glucometer , Electrical Needle Syringe Destroyer , Manual Hub Cutter , Infantometer , Mortuary Cabinet Freezer Single Person/Body , Mortuary Cabinet Freezer Double Person Body , Bleaching Bag 25 Kg , Iron Patient Hospital Bed, Dimension: 2030X900x500mm Non Adjustable With Iv Rod , Iron Patient Hospital Bed Manual Dimension: 3 X 6 Feet , Steel Folding Cot Iron Frame , Laptop Office Bag Multicolour Leather P.U. Office Bag , Rechargeable Led Bulb 9Watt , Rechargeable Ultra Led Torch 0.5 Watt , No Dust Broom Xl , Ceiling Cleaning Broom , Pochha With Bucket , Dust Pan Fibre , Dust Pan Ss/Metal/Iron , Vacuum Cleaner Wet And Dry 1150-Watt , Thermos Stoneware Tea Kettle Set 1000 Ml , Cup And Soucer And Tea Set , Rack For Medicine , Magazine Stand Revolving , Plastic Jar For Water 2 Ltr , Sliding Glass Notice Board 60 X 90 , Sliding Glass Notice Board 90 X 180 , Plastic Mug For Home And Bathroom 1.5Litre , Vehicle Mountable Fogging Machine Operated Electrical Double Blor , Vehicle Mountable Fogging Machine Operated Electrical Single Blor , Commercial Slide Ladder , Presentation Dias Stand Made-Up Stainless - Steel Color Royal Red - Height 4 Ft X 1.5 Ft Width. (For Offices, School, Public Speech & Conferences) , Presentation Dias Stand Made-Up Wooden Width - 61 Cms, Depth - 45 Cms, Height - 123 Cms. Material - Engineered Wood, Laminated Board. Colour - Two-Tone , Photo With Frame Standard Size For Office , Stadiometer (Height Measuring Scale For Adults And Children) , Blanket , Pvc Floor Covering Carpets Width : 1.5 Meter Thickness 0.65, To 1.00 Mm Designs : Mat Finish (Enter Rate In Per Square Meter) , Pvc Floor Covering Carpets Width : 2 Meter Thickness 0.65, To 1.00 Mm Designs : Mat Finish (Enter Rate In Per Square Meter) , Hand Wash Station Foot Operted 1 User With Pvc Water Tank 200 Ltr , Hand Wash Station Foot Operted 2 User With Pvc Water Tank 200 Ltr , Hand Wash Station Foot Operted 3 User , Hand Wash Station Foot Operted 4 User , Automatic Sanitiser Dispenser Machine , Alcohol Based Hand Sanitizer 5 Ltr Can , Alcohol Based Hand Sanitizer/ 500 Ml Sprey Bottle , Alcohol Based Hand Sanitizer 100 Ml Sprey Bottle , Alcohol Based Hand Sanitizer 50 Ml Sprey Bottle , Sodium Hypochlorite 50 Kg Can , Jeevan Drop 100 Ml Bottel , Iron Patient Hospital Bed, Dimension: 2030X900x500mm Non Adjustable With Iv Rod , Iron Patient Hospital Bed Manual Dimension: 3 X 6 Feet , Aluminum Grain Storage Container 100 Kg Capacity , Aluminum Grain Storage Container 50 Kg Capacity , Grain Storage Tank 20 Kg , Water Jar 2 Ltr Capacity Steel , Water Jar 2 Ltr Capacity Pvc , Aluminium Kadai 8 Ltr , Gas Bhatti Single Burner , Gas Bhatti Double Burner , Stainless Steel Round Kitchen Baskset , Aluminium Pot Heavy Patila/Rice Boiler Tope No 18 (10L) Tope 10 L Capacity 26 Cm Diameter , Aluminium Pot Lead For Patila/Rice Boiler Tope No 18 26 Cm Diameter 10L , Water Tank 18 Ltr Steel , Plate Pawbhaji Style , 5 Layer 30 * 30 Inch Wall Mount Modern Kitchen Utensils Dish Rack , Pressure Cooker 5 Ltr , Pressure Cooker 10 Ltr , Pressure Cooker 12 Ltr , Pressure Cooker 14 Ltr , Pressure Cooker 22 Ltr , Ss Milk Can/Oil Can 2 Ltr , Aluminium Pot Heavy Patila/Rice Boiler Tope No 18 (25L) Tope 25 L Capacity 26 Cm Diameter , Aluminium Pot Lead For Patila/Rice Boiler Tope No 18 26 Cm Diameter , Stainless Steel Serving Spoon For Rice Boiler , Stainless Steel Kitchen Pincers/Sandshi/Pakkad , Water Pot/Handa/Beda 10 Ltr Steel Food Grade , Stainless Steel Parat, Material Grade: 202 Size 28 , Stainless Steel Bowl/Vati , Donga Spoon , Spoon Serving Ss To Cqa Steel Sarata , Stainless Steel Serving Tray Large Size , Serving Tray Set Of 3 , Tea Spoon , Break Fast Spoon , Ss Water Glass Standard Size , Chalni/Stainer For Grain , Steel Plate , Chapati/Roti/Papad Manual Maker Press , Stainless Steel Storage Containers With Lead , Capacity: 5Kg , Stainless Steel Storage Containers With Lead , Capacity: 10 Kg , Stainless Steel Storage Containers With Lead , Capacity: 15 Kg , Stainless Steel Storage Containers With Lead , Capacity: 20 Kg , Stainless Steel Storage Containers With Lead , Capacity: 25 Kg , Tople Steel , Tople Plastic/Fibre , Wagrale , Belan Polpat , Iron Kadhai 150 Litre , Aluminium Patila Big 110 Ltr , Stainless Steel 2 Burner Gas Stove, Manual Ignition , Strainer Steel Frying Spoon , Mixer Grinder 550 Watts With 3 Multi Ouroose Grinding Jars , 1.5 Hp Table Top Atta Chakki Mini Flour Mill , Magnetic Sticks Puzzle Game For Kids (36 Pcs) , Interactive Fruit Cutting Game 8-Piece , Tower Block Game , Kids Kitchen Set Game , Rocker Horse/Elephant /Etc Ride On Toy , Fruit Set Multicolour , Abcd Slate And Block , Building Abcd Name , Carrom With Coin, Striker,And Powder , Bat Ball Without Stumps For Kids Up To 12 Year Kids Plastic , Bat Ball With Stump For Kids Up To 12 Year Kids Plastic , Badminton Racket Set Of 2 Bat , Badminton Shuttlecocks 10 Psc Box , Skipping Rope Adjustabe Hights For Kids , Skipping Rope Adjustabe Hights With Counting System , Handcrafted Wooden Indian Traditional Lagori , Teddy Rings - 7 Rings , Magic Speed Rubics Cube Size 2.5 Cube , Standard Cotton Swing , Babys Tricycle (Multi -Colour 86X64x33 Cm, 1-3 Years) , Soft Foam Cricket Bat With Ball For Kids O To 8 Yrs , Vegetable Set, Multi Color , Racket Set With Ball & Shuttlecock For Kids Plastic Table Tennis Set , 12Pc Big Size Animal Kids (12 Pcs Big Animal Set) , Flying Disk For Kids Game 03 To 06 Yrs , Hula Hoop Ring - Multicolour For Kids , Flash Card 9.5 Cmx 1375 Cm Set Of 5 Pcs , Small Board Book Set Of 5 - English - 2 To 5 Year Set Of Five As Per Requirement , Building Block For Kids ,42 Pcs Bag Packing (Multicolour) , Play Ball Set Medium Multicolour Set Of 10 Balls , Play Ball Big Size Set Multicolour Set Of 6 Balls , Abcd/Education Chart 5 Pcs Set 65X55 Cm Aprrox Size , 3D Alphbets Learning And Drawing Book , Magic Slate (Multicolor-Digital Slate Lcd E-Writing Board Electronic Notebook Graphic Tab With Pen) , Basket Ball For Kids , Side Drum Steel 14 Inch With Belt, Stick And 2 Fiber Sheet Free , Thap Dhol Ss,17.2 Inch , Lezim Instruments Standard Size , Wooden Dumbbells For Pt 1 Set , Tennikoit Ring Dotted & Plain(Pack Of 6) , Mrudung / Mridangam , Nickel Plated Handmade Musical Iron Tabla Set , Wooden Standard Harmonium Harmonium , Handmade Jhanjh , Piano Portable Keyboard 61 Keys , Professional Flutes C Sharp Medium Right Hand Bansuri Size 18.5 Inches , Cricket Bat Cricket For Kids 6 To 12 Year Wood , Cricket Ball For Kids 6 To 12 Year , Cricket Stumps For Kids 6 To 12 Year Wood , Cricket Bat Cricket For Kids 12 To 16 Year Wood , Cricket Bat Standard Size , Cricket Tennis Ball Standard Size Box 6 Pcs , Cricket Stumps Standard Size 6 Nos , Foot-Ball Standard Size , Foot-Ball Net Standard Size , Volleyball , Volleyball Net , Kho-Kho Pol Pair Standard Size Wood , Chess Board With Coin , Tent House Jumbo Big Size , Doll House & Accessories For Girls Age 3Y+ , Doll House Playhouse Playset , Doctor Set Kids Game , Toy Counting Frame Plastic , Puzzle Set , Seasaw Toy , Slide , Swing Car L76xw35x48 Approx , Wooden Block Set , Foot Basic Sewing Machine , Frp Indoor Merry Go Round , Outdoor Merry Go Round , Dholki Small For Kids Playing 3 To 12 Yrs , Park Metal Single Swing 10 Feet , Park Metal Double Swing 10 Feet , Park Metal Slide 9 Feet , Magical Handwriting Workbook Pen And Refills , Nursery Board Book , Easy Copy Colouring Book With 12 Shades Wax Crayons , Kids Painting Set , Adjustable 3-In-1 Plastic Swing For Kids With Rope And Accesorries , Dart Game With 2 Dart Pin , Alpha Numeric Plastic Leeter World -Educational Toys , Flash Cards Learning & Education Game , 6 Puzzle Board , Interactive Board , Black Board 4X6 , White/Green Board 3X4 , White-Green Board 4X6 , Writing Chalk Multi Colour 50 Chalk Sticks In The Box , Writing Chalk White Or Single Colour 50 Chalk Sticks In The Box , White Board Marker Pen- Box 10 Nos , Tablet 4 G Sim Supported (10.1) Hd , Mobile 4 G Supported , Mega Phone , Nail Cutter For Kids , Paydan , Round Dust Bin Metal [Blue + Green With 2.5Ft Stand] , Wall Watch Big Size , Fibre Toilet Single User -1 Unit , Fibre Toilet Double User -2 Unit , Fibre Toilet Four User -4 Unit , T-Shirt [24 Number,Pp Cloth] , T-Shirt [26 Number,Pp Cloth] , T-Shirt [28 Number,Pp Cloth] , T-Shirt [30 Number,Pp Cloth] , T-Shirt [32 Number,Pp Cloth] , Lower [24 Number, Sp Cloth] , Lower [26 Number, Sp Cloth] , Lower [28 Number, Sp Cloth] , Lower [30 Number, Sp Cloth] , Lower [32 Number, Sp Cloth] , Shoes & Socks For Boys,Girls 1 Number , Shoes & Socks For Boys,Girls 2 Number , Shoes & Socks For Boys,Girls 3 Number , Shoes & Socks For Boys,Girls 4 Number , Shoes & Socks For Boys,Girls 5 Number , Soft Cotton Washcloths, Napkin, Hankies For Baby , Baby Gift Kit Items Included In The Gift Pack:As Per Technical Sheet , 5 Annual Periodical Maintenance Cable Wire 1 Bundle 80 Meter , 16 Annual Periodical Maintenance Cable Wire 1 Bundle 80 Meter , 5 Annual Periodical Maintenance One Way Electrical Switch , 5 Annual Periodical Maintenance Two Way Electrical Switch , 16 Annual Periodical Maintenance One Way Electrical Switch , 16 Annual Periodical Maintenance Two Way Electrical Switch , 5 Annual Periodical Maintenance Plug Socket 3 Pin , 16 Annual Periodical Maintenance Plug Socket 3 Pin , Fan Regulator Dimmer Switch , 16 Annual Periodical Maintenance Mcb Switch , 32 Annual Periodical Maintenance Mcb Switch , Mcb Swich Box -4 -Door , Mcb Swich Box -8 -Door , Mcb Swich Box -12 -Door , Mcb Swich Box -18 -Door , 16 A Modular Electrical Switch Board, Module Size: 2, Ip65 , 16 A Modular Electrical Switch Board, Module Size: 4, Ip65 , 16 A Modular Electrical Switch Board, Module Size:6, Ip65 , 16 A Modular Electrical Switch Board, Module Size: 8, Ip65 , 16 A Modular Electrical Switch Board, Module Size: 12, Ip65. , 16 A Modular Electrical Switch Board, Module Size: 14, Ip65 , 16 A Modular Electrical Switch Board, Module Size:16, Ip65 , 16 A Modular Electrical Switch Board, Module Size: 18, Ip65 , Dry Soybeans Organic Soybean Seeds 1 Kg Packing(Mahabeej Or Govt A Approved By Nsc,Sfci , Swami Vivekananda Jivan Charitra Motivational Biography Book Marathi , Rashtramata Jijau Charitra Marathi , Bhartache Sanvidhan The Constitution Of India Marathi , Sanskardeep Shraddha Prakashan Marathi Book , Mazi Atmakatha, Autobiography Of Dr. Babasaheb Ambedkar Marathi Book , Lokraja Shahu Maharaj - Vyaktittva Aani Vichar Marathi Book , Yugpravartak Shivaji Maharaj Yanche Charitra Marathi Book , Kalika -V.S. Khandekar Marathi Book , Shyamchi Aai Marathi Book , Ase Ghadale Dr. A.P.J. Abdul Kalam - Marathi Book , Jhansi Chi Rani Laxmi Bai Marathi Book , Rangatdar Goshti Book Set Of (Red,Brown, Yelow,Green,Blue,Pink And Purple Clour Set) Navneet Set Of 7 Books , Hitopadesh Set Of 4 Books Navneet , Gosti Ashya Majach Maja Set Of 4 Book Navneet , Chatur Birbal Set Of 5 Books Navneet , Air Walker Single Out Door Gym , Air Walker Doudle For Out Door Gym , Shoulder Press Single For Out Door Gym , Shouler Press Double For Out Door Gym , Chess Press Single For Out Door Gym , Chess Press Double For Out Door Gym , Horizatial Bar For Out Door Gym , Abdominal Exercise Double For Out Door Gym , Eliticipal Trainer Single For Out Door Gym , Eliticipal Trainer Double For Out Door Gym , Rowing Machine For Out Door Gym , Cycle For Out Door Gym , Sit And Stand Twister For Out Door Gym , Triple Twister For Out Door Gym , Leg Press Double For Out Door Gym , Parallel Bar For Out Door Gym , Surf Board For Out Door Gym , Dipping Bar For Out Door Gym , Bench Press For Out Door Gym , Cross Walker For Out Door Gym , Knee Chair For Out Door Gym , Steeper And Twister For Out Door Gym , Shoulder And Chest Press For Out Door Gym , Horse Rider For Out Door Gym , Leg Stretch For Out Door Gym , Usb Rechargeable Electric Gas Lighter For Kitchen Gas Stove , Rod 4 Feet Zig Zag Indoor Gym , Rod 5 Feet Regular Indoor Gym , Rod 1 Feet Regular Indoor Gym , Standard 28Mm Rubber Weight Plates Indoor Gym , Dumbels Rubber Coated Olympic Rate Per Kg For Any Pair Without Rod And Other Accessories Indoor Gym , Multi Bench Premium(Chest, Leg, Curl, Leg Extension )3 In One Indoor Gym , Leg Curl / Leg Extension Indoor Gym , Bicep Curl Machine Indoor Gym , Adjustable Squat Rack Stand Material Alloy Steel Indoor Gym , Calf Muscle Machine Product Indoor Gym , Stepper With Riser For Indoor Gym , Gym Dumbbell Rack Material Iron, Indoor Gym , Weight Plates Storage Rack For Gym Material ? Indoor Gym , Yoga Mat Indoor Gym , Hbnc Kit For Asha Worker Including Including 9 Items As Per Bom , Multicolour-4K, Matte Vinyl Stickers Educational Rate Per Sq Feet Special Repair No Item Name & Its Technical Specification , Dvr 8/16Channel [Min 2.0Mp(1080P),8Ch Turbo Hd Dvr,H264,H264+ & Dual Stream Video Compression,Hd-Tvi,Support Ahd,Analog Camera With Adaptive Access,Rj45,Usbx2,Mouse Support,Upto 6Tb Hdd Support] , Dome Camera [Lance 3.6Mm,1080P,0.01 Lux @F1.2,0 Lux With Ir, True Day, & Night,,Ir Distance 20 Mm,Dc 12V,4W Max] , Bullet Camera [Lance 3.6Mm,1080P,0.01 Lux @F1.2,0 Lux With Ir, True Day, & Night,,Ir Distance 20 Mm,Dc 12V,4W Max] , Hard Disk For Dvr [Capacity Min 2Tb,Sata6.0Gb/S,Min7200 Rpm, Waranty Min 2Yr] , Cable Bundle [Minimum 80Mtr,Copper 3+1,Min 22Gadge] , Bnc Connector Copper [Screw Adjustable] , Power Connector Copper [Screw Adjustable] , Cctv Fitting Labour Charges [Cctv Cable Fitting,Dvr Installation,Camera Installation] , Power Supply [Min 12Volt,10Amp] , Led Display Screen [Size :19.5 Inch (49.5Cm) Hd (1600X900)Tn Panel, Vga Port,Dsiplay Port,Aspect Ratio: 16:9,Brightness (Typical):250Cd/M,Voltage :120Volts,Wattage:15Watt,Waranty Min 1 Year] , Projector [Projector Brightness: 300 Ansi Lumens Projection Technology: Dlp Projector Native Resolution: Wxga (1280X800) Contrast Ratio (Typical): 2200:1 Native Aspect Ratio: 16:10 Screen Size Compatibility: 36.2 - 362.7 Projection Distance: 1.2 - 10 M Service Life Of Lamp: 3000 Hbulb Power: 260 W Service Life Of Lamp (Economic Mode): 5000 H Throw Ratio: 1.28 -1.536 Ceiling Mount : Optional Accessory, Sold Separately Carrying Case : Optional Accessory, Sold Separatelywarranty : 5 Years For Product, 1 Year For Bulb] Mfg Warranty , Projector Screen [Supports Ultra Hd, 3 D And 4 K Technology, Spring Action Mechanism, Autolock/Instalock Mechanism, You Dont Need To Hook The Screen At The Bottom To Stop Size: - 6 Feet (Width) X 4 Feet (Height), In 4:3 Format, 84 Inches/7 Feet Diagonal Length, Comes With 1.2 Gainapprox.Keeps Your Eyes Strain Free While Viewing, Comes With Anti Uv Coating To Protect Eyes, A+++++ Grade Fabric, Ideal For Presentations, Meeting Rooms, Home Cinema.Comes In Imported Easy To Clean Super High Gain Fabric/Material, Black Coated Screen Material From Back Side Eliminates Light Penetration For Superior Color Reproduction, Complimentary Four Side Black Masking Borders Enhances Picture Contrast,.] , Led Tv 40 Inch Hd Ready (80Cm,Hd Display,Max Resolutions 1366X768,Hdmix2,Usb 2.0 X 2,Vga X 1,Av In X 1, ,Tv (Rf) In X 1, Audio Out X 1) Minimum 3 Year Warranty , Smart Led Tv 40 Inch Hd Ready- Smart Tv Minimum Android Version 4.4, Cpu- Minimum Dual Core 1.2 Ghz Storage Min. 4 Gb, Built In Wifi (80Cm,Hd Display,Max Resolutions 1366X768,Hdmix2,Usb 2.0 X 2,Vga X 1,Av In X 1, ,Tv (Rf) In X 1, Audio Out X 1), Pc Audio In , Ypbpr,Lan,Tf Slot,Audio Out, Spdif Out)- Minimum 3 Year Warranty , Led Tv 32 Inch Hd Ready (80Cm,Hd Display,Max Resolutions 1366X768,Hdmix2,Usb 2.0 X 2,Vga X 1,Av In X 1, ,Tv (Rf) In X 1, Audio Out X 1) Minimum 3 Year Warranty , Smart Led Tv 32 Inch Hd Ready- Smart Tv Minimum Android Version 4.4, Cpu- Minimum Dual Core 1.2 Ghz Storage Min. 4 Gb, Built In Wifi (80Cm,Hd Display,Max Resolutions 1366X768,Hdmix2,Usb 2.0 X 2,Vga X 1,Av In X 1, ,Tv (Rf) In X 1, Audio Out X 1), Pc Audio In , Ypbpr,Lan,Tf Slot,Audio Out, Spdif Out)- Minimum 3 Year Warranty , Speaker System 4.1 [Min Specifications: Usb + Fm+Sdcard, 1 Main Unit,4 Speaker,1 Remote,1 Audio Cable] , Trolley Speaker Small With Wireless Mic Nos -2:: Technical Specifications Wireless Bluetooth Trolley Speaker Digital Karaoke,Treble And Bass Independent Adjustment Professional Treble And ; Bass Gain Controlling Circuit Built-In Professional Wireless Microphone System Built-In Mp3 Encoding Support Connection Type:Bluetooth, Usb , Fm Radio,Tf Card, Aux In Port, Micin Compatible With Dvd/Pc And Other Sound Source Intelligent Power Switch Charging Circuit User Friendly Trolley 8 Meters Operating Range , Upto 4.5 Hours Of Playback Total Output 60W Rms Controls: Sound, Mode And Track Controls Two Wireless Mics And ; Remote Included In Box Subwoofer Size : 12 Inch , Trolley Speaker Medium With Wireless Mic Nos -2: Wireless Bluetooth Trolley Speaker . Digital Karaoke,Treble And Bass Independent Adjustment Professional Treble & Bass Gain Controlling Circuit Built-In Professional Wireless Microphone System Built-In Mp3 Encoding Support Connection Type:Bluetooth, Usb , Fm Radio,Tf Card, Aux In Port, Micin Compatible With Dvd/Pc And Other Sound Source Intelligent Power Switch Charging Circuit User Friendly Trolley 8 Meters Operating Range , Upto 4.5 Hours Of Playback Total Output 80W Rms Controls: Volume, Mode And Track Controls Two Wireless Mics & Remote Included In Box Subwoofer Size : 15 Inch , Trolley Speaker Large With Wireless Mic Nos -2:Wireless Bluetooth Trolley Speaker , Total Output 120W Rms Treble And Bass Independent Adjustment Connection Type: Bluetooth, Usb , Fm Radio,Tf Card, Aux In Port, Mic In Compatible With Dvd/Pc And Other Sound Source User Friendly & Sturdy Adjustable Trolley With Digital Led Display 10 Meters Operating Range Controls: Volume, Mode And Track Controls Two Wireless Mic. Full Function Remote Subwoofer Size : 18 Inches & Tweeter 8 Internal & External Battery Support , Ups 600Va [Minimum Specifications :Capacity:600Va/360W,Nominal Voltage:230Vac,Output Voltage :230Vac,Battery:12V/7Ahx1,Bkp Time:10-15Mins,Max Net Weight :4.2Kg] , Wall Mount Kit Compatible For 32 Tv , Elerning Syllabus Software [Animated With Sound] , Computer System All In One [Cel Quad Core,4Gb Ram, 1Tb Hdd,20 Screen] , Computer System Cpu [Dual Core,2Gb Ram,160Gb Hdd] , Keyboard [Port : Usb, Type:Standerd,Keys Minimum:104] , Keyboard [Wireless , Type:Standerd,Keys Minimum:104] , Mouse [Port :Usb, Type:Optical,Keys :Minimum :03] , Mouse Wireless Type:Standerd,Keys Minimum:104] , Power Cable 1.8Meter For Pc , Vga Cable 1.8 Meter For Pc , Surge Protector [Minimum 4 Port,1 Fuse] , Training Charges , Installation, Labour Charges,Other Charges , Cricket Bat [5Number Full Size,Kashmir Willow] , Rubber Ball [Hevy Tennis] , Rubber Ball [Light Tennis] , Stump Set (3Qty)[Full Size, Kashmir Willow] , Rubber Ring [Regular Plane] , Badmintan Racket Set [Regular] , Football [5Number, Waterproof] , Flying Ring [Fibre,Size:Regular] , Hoops Ring [Fix] , Lagori Set [Lagori Set, Wooden] , Lagori Ball [Lightweight, Rubber] , Skip Rope [Plastick Handle, Rubber Rope,1Mtr] , Hollyball[5Number,Waterproof] , Hollyball Net[Cotton,14Mesh] , Single Slide Min 3Ft , Double Swing , Single Seasaw [Gf-70A, 6] , Toys Installation Charges , Office Chair [High Back)Product Dimensions: Length (21 Inches), Width (21 Inches), Height (48 Inches) Primary Material: Leatherette Color: Black, Style: Modern Adjustable Seat Height Tilt Mechanism Nylon Wheels , Office Chair [Medium Back)Product Dimensions: Length (20 Inches), Width (20 Inches), Height (41 Inches) Primary Material: Leatherette Style: Modern Adjustable Seat Height Tilt Mechanism Nylon Wheels , Office Chair Fibre Product Dimensions: Length (61 Cm), Width (61 Cm), Height (89 Cm) Style: Modern Stylish, Modern And Sturdy Chair Wide Seat With Arm Rest For Comfortable Sitting Experience Suitable For Indoor As Well As Outdoor Distinct Design For Backrest , Fogging Machine [Black Stone] , Educational Wall Chart Set (5Pcs, Animal, Abcd, Number,Fruits,Vegitables) , Height Charts [Ph6031 W20 X H47] , Animal Set [Ph1400] , Fruit Set [Ph8001+Ph8000] , Rocker Toy [Pgs401/F L36 X W13 X H18] , Rideon [Pgs1404 L28.7 X W10 X H20.5] , Mani Slate [Ph155 Counting Frame] , Tedy Ring [Min 5Ring Set] , Plastic Ball Big , Flying Ring [Ph160,D21.5] , Playball Set [Min 50Pcs,Min D6.6Cm Pgs601] , Two Way Essel Board [Pgs 701 L28 X W24 X H42] , Grain Storage [Capacity Min 50Kg , All In One Printer- Main Input Tray 150 Sheets Of Regular Weight 75 G/M2 (20-Lb Paper )Priority Feed Slot 10 Sheets Of Paper Up To 163 G/M2 (43 Lb) Top (Face Down) Output Bin 100 Sheets Of Regular Weight 75 G/M2 (20-Lb Paper )Output Bin60 To 105 G/M2 (16 Lbsto 28Lbs ) Print Speed14 A4 Pages Per Minute (Ppm), 15 Letter-Size Ppm First Page Out In As Low As 8 Seconds Print Resolution Fastres 600: This Setting Provides 600 Dpi Effective Output Quality. Fastres 1200: This Setting Provides 1200 Dpi Effective Output Quality. Economode: Text Is Printed Using Less Toner. Duty Cycle 8,000 Single-Sided Pages Per Month (Maximum) 1,000 Single-Sided Pages Per Month (Average) Power Consumtionas Per Fcc Compliance , Suppluing And Erecting Street Light Fitting Suitable To 30W Lamp, Including Lamp, With Pf0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Extruded Alluminium Complete As Per Specification No Fg-Odf/Fls2 Item No.2-9-3 , Suppluing And Erecting Mains With Isi Mark Wp 2 X 4 Sq.Mm. 1100V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg Gi Binding Wire , Ro Water Filter 25 Ltr [1 Yr Onsite Service, 100+150Gpd Pump Bnqs ,Memron Tfc/Blue Mount X 3, Carben Sandfilter,Bowls] , Ro Water Filter 50Ltr [1 Yr Onsite Service, 100+150Gpd Pump Bnqs ,Memron Tfc/Blue Mount X 3, Carben Sandfilter,Bowls] , Ro Water Filter 100 Ltr [1 Yr Onsite Service, 100+150Gpd Pump Bnqs ,Memron Tfc/Blue Mount X 3, Carben Sandfilter,Bowls] , Ro Water Filter 200Ltr [1 Yr Onsite Service, 100+150Gpd Pump Bnqs ,Memron Tfc/Blue Mount X 3, Carben Sandfilter,Bowls] , Water Tank 4 Layer Tank 500 Ltr , Water Tank 4 Layer Tank 1000 Ltr , Non-Electric Water Purifier It Boasts Of Electro Adsorption Technology (Eat) Based Filter Which Gives The Power Of 4 Filters In One Physical Filter. Water Is Passed Through A 5 Stage Purification Process I.E. One Pre-Filter And 4 Filters Under Eat. The Filter Is Self-Serviceable I.E. We Can Change It Ourself When It Is Required. The Natural Essential Minerals Are Maintained In The Water Thus Giving Us Clean And Healthy Water. This Water Purifier Doesnt Waste Water. Tank Capacity: 6 Litres Flow Rate: 1 Litre Per Minute Life Of Eat Filter: 12 Months 2-Year Warranty And Even Works Under Low Water Pressure Conditions. Non-Electric , Electronic Infant, Baby Weighing Scale Conformity To Indian Standrad, Is:9281-3 (1981) Part I,Ii, Iii & Part Iv (Latest) Yes Bis Marked Yes Display Led Battery Backup True Speed Of Measurement 5 Second Class Type Class-Iii Rated Load/ Capacity(Kg) 20 Kg Backup Time(Hour) 12 Internal Calibration True Power Requirement Mains Operated Battery Operated Battery Type Rechargeable Type Of Sensing Element Load Cell Warranty In Years 1 Tare Provision Manual Number Of Display Single Type Of Electronic Weighing Machine Electronic Infant Weighing Scale Resolution(Gms) 10 G Dc Operating Voltage In Volts 6 Volt Power Supply Single Phasepan/ Platform Size 550 Mm X 300 Mm , Weighing Scale Bis Marked Yes Conformity To Indian Standrad, Is:9281-3 (1981) Part I,Ii, Iii & Part Iv (Latest) Yes Rated Load/ Capacity(Kg) 150 Kg Battery Type Non-Rechargeable Tare Provision Automatic Internal Calibration True Backup Time(Hour) 10 Display Led Power Requirement Battery Operated Type Of Electronic Weighing Machine Electronic Personal Weighing Scale Warranty In Years 1 Number Of Display Single Speed Of Measurement 5 Second Dc Operating Voltage In Volts 6 Volt Power Supply Single Phase Resolution(Gms) 50 Gm Class Type Class-Iii Battery Backup True Type Of Sensing Element Load Cell Pan/ Platform Size 300 Mm X 300 Mm , First Aid Box Dressing Kit Is A Blister Pack With Rigid 3 Chamber Tray Made Of Hard Film Of Min 500 Micron Thicknesses To Provide The Strength While Being Used As A Container The Other Side Should Be Packed With A Medical Grade Paper, With The Thermal Sealing Min 7 Mm Or More As Per International Standard In Easily Peelable Pouch Yes Capacity 30 Milliliter Sterlity Of The Ready To Use Kit Sterile Utility Single Use - Disposable Items In The Kit No Of Gauze Of Different Sizes, 12 Ply, British Pharmacopoeia 17 Type, With All Margins Infolded So That No Loose Thread Is Visible On The Edges 5 No Of Gauze Balls Folded Nicely By Machines Without Any Loose Fibre 5 No Double Teeth Tweezer Made Of Fibre Glass And Polypropylene To Ensure The Adequate Strength In Holding The Articles 1 No Of Non Woven Sheets Of Different Sizes With Excellent Liquid Barrier Properties 1 No Of Dressing Pads Of Different Sizes Highly Absorbable Inner Cellulose Layer Completely Sealed In Nonwoven Covering To Hold The Liquid Inside The Pad And Avoid Seepage 1 No Of White Hand Towels, Made Of Wood Pulp Paper , Tds Meter Type Microprocessor Based Display Led / Lcd / Touch Screen, 3 Digits Calibration Up To 3 Points With Auto Buffer Ph Range (Ph) 0.00 To 14.00 Accuracy (Ph) +- 0.05 Corrosion Resistant Yes Power Requirements 230 V +- 10, 50 Hz Ac Modes Ph Mv- C Parallel Temperature Indication Yes Temperature Compensation Type Automatic Temperature Accuracy (Degree C) +- 0.3 Temperature Compensation Range (Degree C) 0 To 100 Resolution (Ph) 0.01 Operating Humidity: Rh In (%) 0 Operating Temperature (Degree C) -1 , Click Scanner Document Book Scanner Type Table Top (Without Computer And Display Screen) Technology Digital Camera Scanning Image Sensor Chip Ccd Embedded Pc Configuration If Applicable No Size Of Touch Screen Diagonally , If Applicable (Cm) No Glass Plate To Provide Flat Images Not Available If Available, Shape Of Glass Plate Flat Movement Of Glass Plate Manual Number Of Digital Cameras 1 Scan Area (Book Size When Open) A3 Maximum Book Thickness (Mm) 125 Optical Resolution (Dpi) 200 Scan Speed (Sec Per Scan) 1 Processing Time / Cycle Time (Scanning + Image Processing + Storage) (Seconds) 10 Buffer Memory (Mb) 8 Light Source Na Scan Mode (Colour Format) Colour / Black & White / Gray Scale Optical Zoom No Book Holder / Cradle Flat Bed,Manually Adjustable V-Shaped Cradle,Motorized V-Shaped Cradle,Inverted V-Shaped Glass Platen,Folder Mode Book Position During Scanning Face-Down On Flat Bed With Book Edge Working Mode (Page Turning) Manual Scanner Inter Face: (Computer Connection To Scanner Nil Network Interface (Gigabit Fast Ethernet With Tcp/Ip) No Applications Programming Interface (Api) Nil Output Formats Nil Supported Operating Systems Window 10 Image Processing Abilities Nil Overall Dimensions (Lxwxh)(Mm X Mm X Mm) 100X1000 Net Weight (Kg) 1 Max Power Requirements (Watt ) 60 Operating Temperature (Degree C) 45 Operating Humidity (% Rh) 42 Availability Of Test Reports From Central Govt/Nabl/Ilac Accredited Lab Showing Conformity To The Specifications (Test Reports Are To Be Furnished When Demanded By Buyer) Yes If Yes,Test Report Number Na If Yes,Test Report Date Na If Yes,Name Of Test Lab Na If Yes,Address Of The Test Lab Na Free Installation, Commissioning And Demonstration Yes On Site Oem Warranty (Year) 1 , All In One Printer =Minimum Technical Specification Machine Type Mono Laser All-In-One Available Functions Print, Copy And Scan Printer Print Speed Up To 18 Ppm (A4) Printing Method Monochrome Laser Beam Printing Print Quality Up To 1200 X 600 Dpi With Automatic Image Refinement Print Resolution 600 X 400 Dpi First Print Out Time 7.8 Secs Printer Languages Ufrii-Lt Print Margins 5 Mm-Top, 6 Mm- Bottom, 5 Mm-Left And Right Toner Saver Mode Yes Copier Copy Speed Up To 18 Ppm (A4) First Copy Output Time (Fcot) Approx. 12 Seconds Or Less Copy Resolution Up To 600 X 600 Dpi Copy Modes Text, Text/Photo, Text/Photo+, Photo Multiple Copy Up To 9 Copies Reduction / Enlargement 50-200% In 10% Increments Toner Saver Mode No Other Features 2 On 1, Id Card Copy Scanner Type Colour Scan Resolution Optical: Up To 600 X 600 Dpi Enhanced: Up To 9600 X 9600 Dpi Colour Scanning Depth 24 Bit/24 Bit (Input/Output) Greyscales 256 Levels Compatibility Twain, Wia Max. Scan Width 216 Mm Media Handling Scanner Type Flatbed Paper Input (Standard) 150-Sheet Tray Paper Output 100-Sheet Media Types Plain Paper, Heavy Paper, Recycled Paper, Transparency, Label, Envelope, Index Card Media Sizes Tray: A4, B5, A5, Executive, Envelope (Com10, Monarch, Dl, B5, C5), Ltr, Lgl, Statement, Custom Sizes: Width 76 X 216 Mm; Length 127 X 356 Mm. Media Weights Tray: 60 To 163 G/M² Interface & Software Interface Type Usb 2.0 Hi-Speed Operating System Compatibility Windows 7/2000/ Xp/ Vista Mac Os X Version 10.4.9 - 10.7.X¹linux² Software And Printer Management Scanning Tolls General Features Duty Cycle Max. 8,000 Pages Per Month¹ Warm-Up Time Approx. 10 Seconds From Power On Memory64 Mb Control Panel 1 Digit Led Operating Environment Temperature: 10 To 30ºc (50 To 86ºf) Humidity: 20 To 80% Rh (No Condensation) Power Source 220-240 V (±10%), 50/60 Hz (±2 Hz) Power Consumption Maximum: Approx. 960W Active: Approx. 450W Sleep Mode: Approx. 1.4 W Typical Electricity Consumption (Tec): 0.6 Kwh Noise Levels Sound Power Active: 65.3Db Or Less, Standby: 43.0Db Or Less Sound Pressure Active: 50.4Db, Standby: Inaudible Consumables Cartridges Cartridge 725 (1,600 Pages¹)² , Bio Metric Attendance Recorder Machine Specification Type Embedded Linux Based Biometic Attendance System Screen Size (Inch) 3 = N 5 Screen Resolution (Pixels) 800 X 480 Processor Speed (Mhz) 800 Ram (Gb) 1 Internal Storage (Gb) 4 Usb Port (Numbers) 1 Micro Usb Port Yes Battery Back Up Yes Network Connectivity Lan(Ethernet) Interface Only Mifare Card Support Yes Gprs Yes Internal Speakers Yes Queue Throughput (Number Of People To Mark Attendance Within One Minute) (Number) 20 Stqc Certified Biometric Identification Device Single Fingerprint Scanner Operational Endurance 24 X 7 Device Casing Material Polycarbonate Casing Thickness (Mm) 157 Ingress Protection Ip 65 Api/Sdk Stqc Uidai Certified Register Device (Copy Of The Certificate To Be Furnished , If Demanded By The Buyer) Yes Finger Placement The Fingerprint Scanner Should Be Ergonomically Placed To Support Ease Of Usage For Biometric Attendance In Standing Posture Of The User Drop Test Compliance For Casing From A Height Of 1 Meters No Drop Test Compliance For Casing From A Height Of 2 Meters No Separate Charging Non Usb Port Availabilty With Ac Adaptor Yes Rohs Compliant Certificate Yes Bis Under Crs Of Meity Yes Bis Registration Number Na Type Test Certificate Covering All Parameters And Environmental Tests From Stqc Certified Lab No If Yes ,Ttc Number And Date Na If Yes ,Name Of The Lab Na If Yes ,Address Of The Lab Na On Site Oem Warranty 1 , Steel Almarih /Kapat Without Lockers Conformity To Indian Standard Is:3312 Latest True No Of Shelves (Nos) 4 Type Of Shelves Fixed Locker Provided False Cloth Hanging Provision In The Almirah False Number Of Doors (Nos) 2 Door Stiffner Upto Full Door Height Provided With The Almirah Doors True Umber Of Hinges With Each Door (Nos) 3 Construction Welded Lock Three Way Bolting Device Controlled By Lock Material Material M.S Sheet Conforming To Commercial Quality Cr- 1,Grade 340 Of Is 513:2008 (Reaffirmed 2013)(Fifth Revision)Amdt. No.1 Material Of Almirah Doors M S Sheet Sheet Thickness Of Locker 0.8 Mm Sheet Thickness Of Door In Mm 0.8 Mm (Minimum) Sheet Thickness Of Sides,Back , Top And Bottom 0.8 Mm (Minimum) Sheet Thickness Of Shelves 0.6 Mm Sheet Thickness Of Pedestal In Mm 0.8 Mm (Minimum) Material Of Lock Brass And Steel Finish Material Of Keys Steel Dimension Height (Without Pedestal) (In Mm) (+/- 10 Mm) 1855 Width In Mm (± 7 Mm) 910 Millimeter Depth In Mm (±5 Mm) 430 Millimeter Inside Height Of Locker In Mm (± 5 Mm) N.A Inside Width Of Locker I Mm (±5 Mm) 910 Mm Inside Depth Of Locker In Mm (±5 Mm) 430 Mm Width Of Stiffner In Mm (±5 Mm) 115 Mm Thickness Of Ms Sheet Of Stiffner (In Mm) 0.6 Mm Stiffened Pedestal Height In Mm (±2 Mm) 120 Pedestal Width In Mm (±2 Mm) 70 Colour & Finish Finish Synthetic Enamel Colour Of Paint As Per Work Order Packing: Gutta Packing , 80 Kg Home Gym Indoor Package:(Rubber Plates) Of 20 In 1 Bench With 3Ft Curl And 5Ft Plain Rod, Gym Accessories And Dumbbell Rods 80Kg Pure Rubber, Weight 10Kg X 4Pcs 5Kg X 4Pcs 3Kg X 4Pcs 2Kg X 4Pcs 20 In 1 Bench (Features: Incline, Decline, Flat, Leg Curl And Leg Extension, Chest Press/Butterfly, Lat Pull Down, Ground Pulley, And Dips, Arm Curl) 3Ft Curl Rod And 5 Ft (25Mm) Plain Rod One Pair Of Dumbbell Rods, Hand Gripper, Hand Gloves And Skipping Rope , Weight Lifting Bar -4 Feet Utility Men Mass Of Bars 20 Kg ( Men ) Length Of Bar 1220Mm ( Men ) Diameter Of Grip Section 28 Mm ( Men ) Length Of Each Sleeve 41.5 Cm ( Men ) Rim Diameter 7.3 To 8.0 Cm ( Men ) Diameter Of Bar 28 Mm ( Men ) Knurling In Grip Section 2 Grip Sections Of 44.5 Cm With Nonknurled 0.5 Cm Strip 19.5 Cm From Inner Sleeve With Centre Knurling Of 12 Cm Long ( Men , Weight Lifting Bar -5 Feet Utility Men Mass Of Bars 20 Kg ( Men )Length Of Bar 1524Mm ( Men )Diameter Of Grip Section 28 Mm ( Men ) Length Of Each Sleeve 41.5 Cm ( Men ) Rim Diameter 7.3 To 8.0 Cm ( Men ) Diameter Of Bar 28 Mm ( Men ) Knurling In Grip Section 2 Grip Sections Of 44.5 Cm With Nonknurled 0.5 Cm Strip 19.5 Cm From Inner Sleeve With Centre Knurling Of 12 Cm Long ( Men , Weight Lifting Bar 7 Feet Utility Men Mass Of Bars 20 Kg ( Men ) Length Of Bar 2200Mm ( Men ) Diameter Of Grip Section 28 Mm ( Men ) Length Of Each Sleeve 41.5 Cm ( Men ) Rim Diameter 7.3 To 8.0 Cm ( Men ) Diameter Of Bar 28 Mm ( Men ) Knurling In Grip Section 2 Grip Sections Of 44.5 Cm With Nonknurled 0.5 Cm Strip 19.5 Cm From Inner Sleeve With Centre Knurling Of 12 Cm Long ( Men , Dumbels Rod 1Foot Heavy Duty Workout Bars/Dumbbell Rods Length:-14Inches Material:-Steel Rod With Plastic Firm Hold Grip Nickel Electroplated To Protect It From Corrosion 14Inches Rods X2pcs. + Locks To Hold Plates 4Pcs , Dumbels Plate 2.5Durable & Robust Technology Plates: The Plates Are Made Up Of Pvc Plastics Material Embedded With Solid Concrete, Suitable For Universal Gym Exercises Enabled Withhugebearingcapacityandrobusttechnology Pvc Coating: The One-Piece High Quality Inspected, A Tough Premium Pvc Casing Covers Each-Plate Ergonomic Design: Designed With Latest Manufacturing Tech. To Give Uniform And Perfect Finish To Each & Every Weight Plate Ideal For Home Gym: A Perfect Choice For Home Fitness Daily Regime And Workout Sessions With Family. Best In Class Product For Gym Owners, Office Going Fitness Freaks And Trainers Best Suited For Complete Muscle Workout: Premium International Standard Quality Pvc Weight Plates That Are Used In Exercises For Building Triceps, Biceps, & For Arm Muscles While Maintaining A Complete Balance Of Power, Strength And Control , Dumbels Plate 5 Durable & Robust Technology Plates: The Plates Are Made Up Of Pvc Plastics Material Embedded With Solid Concrete, Suitable For Universal Gym Exercises Enabled Withhugebearingcapacityandrobusttechnology Pvc Coating: The One-Piece High Quality Inspected, A Tough Premium Pvc Casing Covers Each-Plate Ergonomic Design: Designed With Latest Manufacturing Tech. To Give Uniform And Perfect Finish To Each & Every Weight Plate Ideal For Home Gym: A Perfect Choice For Home Fitness Daily Regime And Workout Sessions With Family. Best In Class Product For Gym Owners, Office Going Fitness Freaks And Trainersbest Suited For Complete Muscle Workout: Premium International Standard Quality Pvc Weight Plates That Are Used In Exercises For Building Triceps, Biceps, & For Arm Muscles While Maintaining A Complete Balance Of Power, Strength And Control , Dumbels Plate 7.5 Durable & Robust Technology Plates: The Plates Are Made Up Of Pvc Plastics Material Embedded With Solid Concrete, Suitable For Universal Gym Exercises Enabled Withhugebearingcapacityandrobusttechnology Pvc Coating: The One-Piece High Quality Inspected, A Tough Premium Pvc Casing Covers Each-Plate Ergonomic Design: Designed With Latest Manufacturing Tech. To Give Uniform And Perfect Finish To Each & Every Weight Plate Ideal For Home Gym: A Perfect Choice For Home Fitness Daily Regime And Workout Sessions With Family. Best In Class Product For Gym Owners, Office Going Fitness Freaks And Trainers Best Suited For Complete Muscle Workout: Premium International Standard Quality Pvc Weight Plates That Are Used In Exercises For Building Triceps, Biceps, & For Arm Muscles While Maintaining A Complete Balance Of Power, Strength And Control , Dumbels Plate 10Durable & Robust Technology Plates: The Plates Are Made Up Of Pvc Plastics Material Embedded With Solid Concrete, Suitable For Universal Gym Exercises Enabled Withhugebearingcapacityandrobusttechnology Pvc Coating: The One-Piece High Quality Inspected, A Tough Premium Pvc Casing Covers Each-Plate Ergonomic Design: Designed With Latest Manufacturing Tech. To Give Uniform And Perfect Finish To Each & Every Weight Plate Ideal For Home Gym: A Perfect Choice For Home Fitness Daily Regime And Workout Sessions With Family. Best In Class Product For Gym Owners, Office Going Fitness Freaks And Trainers Best Suited For Complete Muscle Workout: Premium International Standard Quality Pvc Weight Plates That Are Used In Exercises For Building Triceps, Biceps, & For Arm Muscles While Maintaining A Complete Balance Of Power, Strength And Control , Dips Stand 1Par X450 Easy-Dismantle, Convenient And Portable, Foam Handles Suitable For Power Push Up Training With Daily Use You Can Achieve To Narrow The Abdomen, Hips, Chest While Strengthening Your Upper Abdomen, Chest Shoulder And Triceps, Biceps Suitable For Home Use And Travelling Taking Comes In Compact Design And Ergonomic Handles For A Comfortable And Secure Grip , Bench Press Multy Purpose 6 Versatile Positions Flat, Incline And Decline (F.I.D Bench) Strong Tubular Metal Frame Makes This Machine Extra Sturdy Chip Resistant Frame Coated With Epoxy Powder Easy Self Assembly Required (Full Manual Included) , Garbagecar/Ghantagadi Type Of E Cart Fully Electric, Battery Operated Motor Driven For Carrying Bins Colour Of E Cart Green And Bluethe E Cart Must Fabricated From Good Quality Steel Properly Painted To Avoid Rusting For More Than 5 Years, Yes Name And Grade Of Steel From Which E Cart Body Framed Crca Steel Kerb Weight Of E- Cart (Kg) 370 Kilogram Garbage Carrying Capacity (Kg) 310 Kilogram Run Distance (For A Full Charge Of Battery , To Be Tested With Full Load At Maximum Ais-040 )) (Km) 120 Number Of Bins 2 Capacity Of Individual Bins In Litres (Ltrs) 249 Liter Type Of Chassis For E Cart Monocoque Pressed Section Ground Clearance As Per Is : 9435 (Mm) 180 Wheel Base (Mm) 935 Millimeter Turning Radius (Mm) 1698 Millimeter Power Transmission From Motor Shaft To Wheels Direct Mounting Please Specify The Mechanical Mechanism Otherwise Put Na Na Type Of Battery As Per Ais-048 Lead Acid , Ev Grade , Tubular Deep Discharge Capacity Of The Battery Approved By Icat/Arai (Ah) 100 Battery Voltage ,Nominal (Volts) 48V Maximum Overall Dimensions Of The Battery ( L X Wx H ) (Mm3) 400X170x210 Nominal Filled Weight Of The Battery (Kg) 29.7 Kilogram Motor Controller ( Must Suitable For Starting, Accelerating, Ecelerating, Driving , And Stopping Of E Cart Availabile Battery Charger 220/230 V Nominal Input Voltage , High Efficiency Type Charging Current (A) 15 Type Of Motor Brushless Dc Motor Motor Output Power ,48V/60V At Full Load (Watt) 1209 Overall Efficiency Of The E Cart ( To Be Tested At Full Load With Maximum Speed As Per Concerned Ais Standards (%) 85 Gradeability Of E-Cart , ( To Be Tested At Full Procedure As Per Ais -003 Load (Degree) 75 Certification Vehicle Certification Arai If Vehicle Certification From Others Agency ,Name Of The Agency Otherwise Put Na Arai Vehicle Certification Number And Date Aalb 0283 1 Sep 2016 Constructional Seating Facility For Driver Only Length Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct , 2014 (Meters) 1.69 Width Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct, 2014 (Meters) 0.987 Height Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct , 2014 (Meters) 1.695 Dimensions Of The Cabin Provided For Bins (Mm X Mm X Mm) (Mm3) 1328X986x356 Size Of Front Tyre (Mm) 3.00-12 Size Of Rear Tyre 3.00-12 Brake Type (Front) Drum Brake Type ( Rear ) Drum Suspension System (Front) Shock Absorbers With Compression Spring Suspension System ( Rear ) Leaf Spring And Hydrolic Reverse Gear Facility Yes The Mounting Of Batteries Yes Vehicle Lighting System Lcd Based Instrument Panel Containing Speedometer And Battery Charging Indicator Yes Glass Windshield With Wiper Motor As Approved By Icat/Arai Yes Battery Make As Per Ais :048:2009 , Kachara Gadi /Hand Trolley (Collecting Garbage) Collection Conforming To Indian Standard Is 4184: 1967: Latest For Two Wheels Type Wheel Barrowproduct Isi Marked No Cm/L Number Na Nominal Capacity Of Wheel Barrow 110 Liters (Two Wheel Type Wheel Barrow) Material Used For Manufacture Steel Sheets (Steel Sheets Shall Be Not Less Than 1.60 Mm In Thickness, And Shall Conform To Is : 1079 ) Type Of Chassis Frame Any Other Suitable Steel Section, Such As Flat Of Size 30 X 6 Mm Wheel Material Ms With Solid Rubber Tyre Minimum Diameter Of The Axle / Spindle (Mm) 25Minimum Nominal Width Of Tyre (Mm) 50 Minimum Diameter Of The Wheel (Mm) 300 Minimum Bearing Length Of Axle/Spindle 25 Mm At Each End Type Of Bearing / Bush Cast Iron Maximum Clearance Between The Bearing And Axle (Mm) 0.5 Finish Of Metal Parts Other Finish Finish Other Than Two Coats Of Black Bituminous Paint And Galvanised Yes Availability Of Test Report From Nabl/ Ilac Accredited Or Central Government Lab To Prove Conformity Of Products To The Specification. Yes , Garden Bench Governing Specification Surface Mount Reinforcement Bench Conforming To Rdso Specn. (Item No. 172020 Of Ussor) Design Conforming To Drawing No. Rdso/Wks/2014/3 Date : 07.11.2014 Technique Compaction Technique And With Reinforcement Conforming To Govng. Specn. Hair Basisscope Of Supply Scope Of Supply Includes Erection And Installation Of Precast Concrete Reinforce Benches With Backrest Construction Of Bench With Concrete Mix Design - Reinforcement Steel - Connections - And Paint Members Of Bench Reinforced Cement Concrete Base Support And Planks Installation Each Seating Plank ( Bottom ) Of Bench Bolted With Leg By Help Of 12 Mm Dia. X 65 Mm Length Galvanized Steel Countersunk Bolts With Eva Washer - Backrest Planks Fitted With Half Threaded Carriage Bolts And Nuts Of Size 165 Mm X 8 Mm Dia With Eva & Steel Washer Material Concrete Mix Design M-30 Grade Concrete Mix In Accordance With Is : 10269/Latest In Gray Cement By Using Vibro - Compaction Technique And With Reinforcement As Detailed In Govng. Specn. Reinforcement Steel Tmt Reinforcement Bars Conforming To Is : 1786/Latest Of Dia 10 Mm Used As Main Reinforcement Bar And 4 Mm Dia Mild Steel Bars Used As Stirrups As Per Drawing Tirrups Details 10 Nos. - 4 Mm Dia Bar @ 150 Mm C/C Main Reinforcement Bar 4 Nos. - 10 Mm Dia Bar Adequate Clean Concrete Cover 15 Mm Minimum Material For Connecting Seating Plank With Leg 12 Mm Dia X 65 Mm Long Galvanized Steel Countersunk Bolts Confmg. To Is : 1367 / Latest With Eva Washer Material For Connecting Back Rest Plank With Leg Half Threaded Carriage Bolts And Nuts Of Size 165 Mm Length X 8 Mm Dia With Eva And Steel Reinforced Cement Concrete Planks Using M-30 Grade Gray Cement Mixed With 3 % Red Pigment Dimension , Inverter With Battry Inverter Governing Specification Generally Conforming To Is:13314 Rating In Kva & Min. Vah Capacity Of Battery 2 Kva/8640 Vah Technology Mosfet-Pwm Energy Star Rating 5 Star Trolley With Trolley Type Of Battery Tubular Battery Confirming To Is:13369 Backup Time (Minutes) Minimum 180 Minutes Constructional Thickness Of Sheet For Trolley (In Mm) Minimum 1.2 Trolley Material Crca Steel Type Of Enclosure Crca Steel Thickness Of Sheet For Enclosure ( In Mm) Minimum 1.2 Inverter Shall Have By Pass Facility Yes Functional Total Harmonic Distortion /=5% Input Single Phase Sine Wave(120 To 260 V) Output Single Phase Sine Wave 230 V Inverter Efficiency (%) /=87% Overload Time (In Minutes) /=10 Overload Of Rated Load (In %) /=10 Protection Battery Cut-Off Voltage To Protect From Overdischarge (In Volt) 10.5 Degree Of Protection Ip 21 Metering And Indications The Inverters Shall Be Provided With Output Voltage And Current Meters Conforming To Is 2419 : 1979 And Of An Accuracy Class Not Inferior To 2.5 In Accordance With Is 1248 : 1983 Yes Certifications Availability Of The Type Test Report From Central Govt. /Nabl/Ilac , Types Of Lead Acid Of Battery Stationary Cells And Batteries, Lead Acid Type (With Tubular Positive Plates) Conforming To Is:1651/1991 Nominal Voltage Of Battery (Volts) 12.0 Volt Material Of Container Polypropylene Batrry 150 Ted Capacity At C20 Discharge (Ah) 200 Warranty (Years) 1 Year Battery Condition Charged Constructional Dimensions (L X W X H) (Mm X Mm X Mm) As Per Relevant Is Specifications Volume Of Electrolyte (Ml) 5000 Weight Of Dry Battery (Kg) Shall Be As Per Relevant Is: Specn., Corresponding Ah Yes. No.Of Cells Per Battery (No.) 6 Cells For 12 Volt Battery , Air Cooler Large General Features For Rooms Up To (Mt.3 *) 142 Engg. Plastic (Blower / Fan) Double Blower Tank Capacity (Up To Brim- L) 110 Remote Control N/A Auto Louver Movement Yes Cool Flow Dispenser Yes Empty Tank Alarm Yes Cooling Media Hybrid Mosquito Repellent Yes Electronic Humidity Control Yes Air Throw Distance (Mt) 7 / 24 Natural Mode Yes Sleep Mode Yes Off Timer Yes Fully Closable Louver Yes Automatic Horizontal Louver Yes Automatic Vertical Louver Yes Ergonomic Handle Of Easy Movement Yes Easy Removable Cooling Pads Yes Voice Assist Yn/A I-Pure Technology Yes Wattage 230V / 50Hz 205 Product Dimensions (Mm) Length 763 Breadth 430 Height 1235 Carton Dimensions (Mm) Length 810 Breadth 450 Height 1275 I-Pure Technology Smell Filter Yes Bacterial Filter Yes Allergy Filter Yes Uvc Germicidal Yes Pm2.5 Wash Filter Yes , Air Cooler Medium General Features For Rooms Up To (Mt.3 *) 127 Engg. Plastic (Blower / Fan) Fan Blower/Fan Diameter (Mm) 358 Speed Control 3 Tank Capacity (Up To Brim- L) 70 Remote Control No Auto Louver Movement Yes Cool Flow Dispenser Yes Empty Tank Alarm No Cooling Media Honeycomb I-Pure Technology Yes Wattage 230V / 50Hz 205 220V / 60Hz 350 110V / 60Hz 365 Product Dimensions (Mm) Length 635 Breadth 500 Height 1125 Carton Dimensions (Mm) Length 600 Breadth 475 Height 1175 Product Weight (Kgs) 14.9 Product Weight Incl. (Pack) (Kgs) 18.8 No Of Units Per 40Ft Container (Hc) 188 I-Pure Technology Smell Filter Yes Bacterial Filter Yes Allergy Filter Yespm2.5 Wash Filter Yes , Air Cooler Small General Features For Rooms Up To (Mt.3 *) 71 Engg. Plastic (Blower / Fan) Double Blower Tank Capacity (Up To Brim- L) 55 Auto Louver Movement Yes Cool Flow Dispenser Yes Cooling Media Aspen Air Throw Distance (Mt) 7 / 24 Automatic Vertical Louver Yes Ergonomic Handle Of Easy Movement Yes Easy Removable Cooling Pads Yes Wattage 230V / 50Hz 205 Product Dimensions (Mm) Length 763 Breadth 430 Height 970 Carton Dimensions (Mm) Length 810 Breadth 450 Height 1010 , Air Condition 1 Ton Split Inverter Ac Capacity (Watts) 3440 Energy Efficiency (Iseer) 5.2 Moisture Removal (L/Hr) No Noise Level (Indoor High/Low) No Compressor Type Invertor Power Consumption 830 Watts Voltage No Auto Restart Yes On Timer Yes Off Timer Yes Dehumidification No Sleep Yes Swing Yes Remote Control Yes (Lcd) Indicators Yes Indoor Unit Size (W X D X H) Cm 84.5 X 18.0 X 27.5 Outdoor Unit Size (W X D X H) Cm 82 X 30 X 54 Indoor Unit Weight (Kg) 12.5 Outdoor Unit Weight (Kg) 33 Warranty 1 Year On Functioning And 10 Year On Compressor 5 Year Condenser Other Features R290 Greenest Refrigerant Auto Clean/Blow Function Memory Function Auto Mode Silver Ion Filter Turbo Mode Dry Mode Sleep Mode Auto Restart 10 Year Compressor Warranty & 5 Year Condenser Warranty , Air Condition 1.5 Ton Split Inverter Ac Capacity (Watts) 5000 Energy Efficiency (Iseer) 4.9 Moisture Removal (L/Hr) No Noise Level (Indoor High/Low) No Compressor Type Invertor Power Consumption 1350 Watts Voltage No Auto Restart Yes On Timer Yes Off Timer Yes Dehumidification No Sleep Yes Swing Yes Remote Control Yes (Lcd) Indicators Yes Indoor Unit Size (W X D X H) Cm 94 X 20 X 29.8 Outdoor Unit Size (W X D X H) Cm 85 X 40 X 59 Indoor Unit Weight (Kg) 16 Outdoor Unit Weight (Kg) 39 Warranty 1 Year On Functioning ,10 Years Compressor Warranty & 5 Years Condenser Warranty Other Features R290 Greenest Refrigerant Auto Clean/Blow Function Memory Function Auto Mode Silver Ion Filter Turbo Mode Dry Mode Sleep Mode Auto Restart 10 Year Compressor Warranty & 5 Year Condenser Warranty , Air Condition 2 Ton Split Inverter Ac Capacity: 2 Ton Rating: 5 Star Iseer: 4.9 Capacity: 2 Ton(S) Bee Rating: 5 Star Ac Type: Split Usage: Office Warranty: 3 Year(S) Features: 7 Years Compressor Warranty, Auto Mode, Copper Condenser And Connecting Pipe, Dry Mode, Environment-Friendly R410a Efrigerant Timers: Yes Auto Restart: Yes Sleep Mode: Yes Remote Control: Yes Active Carbon Deodoriser: Yes Catechin Filter: Yes Color: White Dimension: 800X300x690 Weight: 45 Cooling Capacity (Watts): 6155 W Power Input (Watts): 1784 W Copper Condenser 7 Years Compressor Warranty Eco-Friendly Refrigerant Other Features R290 Greenest Refrigerant Auto Clean/Blow Function Memory Function Auto Mode Silver Ion Filter Turbo Mode Dry Mode Sleep Mode Auto Restart 10 Year Compressor Warranty & 5 Year Condenser Warranty , Color Printer Printer Type - Ink Tank; Functionality - All-In-One (Print, Scan, Copy) , Scanner Type - Flatbed; Printer Output - Colour Connectivity - Usb This Printer Comes With 2 Extra Bottles Black Ink In The Box, In Addition To 1 Each Of Cyan, Yellow, Magenta And Black Pages Per Minute - 33 Pages (Black & White), 15 Pages (Colour) ; Cost Per Page - 7 Paise (Black & White), 18 Paise (Colour) - As Per Iso Standards Ideal Usage - Home And Small Office, Regular / Heavy Usage (More Than 300 Pages Per Month) Page Size Supported - A4, A5, A6, B5, C6, Dl ; Duplex Print - Manual ; Print Resolution - 5760 X 1440 Compatible Ink Bottle - T6641 (Black), T6642 (Cyan), T6643 (Magenta), T6644 (Yellow) ; Page Yield - 4500 Pages (Black & White), 7500 Pages (Colour) Warranty - 1 Year , Supplying Installing Testing & Commissioning Solar Street Light Pole Comparing Of 9 W Led Fitting 12 V Min Ah Maintanance Free Lithium Battry Box Weatherproof Mounted On 75/80 Mm Brackets Foundation Earthing And Nessasaery Accesaries Complite As Per Specification No - Esd-Sol-Stl(4-3-11) , Providing Ms Boxex With Locking Arren- Gement Fitting Etc , Providing And Fixing Of Retro-Reflectorised Informatary Sign Board Rectangular/Square Meter Made Out Of 2Mm Alluminium Sheet Bonded With White Reflective Sheeting Of Class B , Refrigerator Small Number Of Doors Single Door 5 Star Ratings Refrigerator Capacity (Total) 99 L Defrosting Type Direct Cool Shelf Type Wire Number Of Shelves 2 Voltage Range 140-260V Hfc And Cfc Free Yes Color Wine Red Dimension (Mm) 850 X 487 X 568 Warranty 10 Year Compressor Warranty Other Features Interior Light: Bulb Anti-B Technology: Yes 100% Environment Friendly Low Starting Voltage Uninterrupted Cooling Runs On Home Inverter 24 Hour Freshness , Refrigerator Medium Number Of Doors Single Door 5 Star Ratings Refrigerator Capacity (Total) 181 L Defrosting Type Direct Cool Shelf Type Wire Number Of Shelves 2 Voltage Range 140-260V Hfc And Cfc Free Yes Color Candy Wine Dimension (Mm) 1128 X 541 X 661 Warranty 10 Years Compressor Warranty Other Features Door Lock 2.5L Aqua Space In Door Shelf Interior Light: Bulb Anti-B Technology: Yes 100% Environment Friendly Low Starting Voltage Uninterrupted Cooling Runs On Home Inverter 24 Hour Freshness , Refrigerator High Number Of Doors Single Doornumber Of Doors Single Door 5 Star Ratings Refrigerator Capacity (Total) 210 L Defrosting Type Direct Cool Shelf Type Toughened Glass Number Of Shelves 2 Voltage Range 110-260V Hfc And Cfc Free Yes Color Pearl Wine Dimension (Mm) 1341 X 577 X 667 Warranty 10 Years Compressor Warranty Other Features Max Savings With Inverter Technology Runs On Home Inverter 24 Hour Freshness , Sewing Machines Specification Indian Standrad For Household Sewing Machines Is:1610 Latest Certification Isi Marked Yes Cm/L No And Date (If Yes) 23112018 Sewing Mechanism Design Single Needle Design For Producing Two Thread Lock Stitch. Reverse Stitch Mechanism Yes Thread Spool Pin Yes Driving Arrangement Driving Arrangements Foot Operated Machine Electric Motor Conforming To Is 996 Latest For Motor Driven Machine Yes Starting Switch For Electic Motor Yes Speed Controller For Electric Motor Yes Pulley And Belt For Electric Motor Yes Safety Requirements Connforming To Is302(Part I)Latest For Electrical Equipment Used Yes Table/ Base/ Stand Table/ Base/ Stand Integral Part Of Sewingmachine Yes Wooden Table Or Base Conforming To Is 12789 Latest Yes Stand(If Supplied) Conforming To Is 12740 Latest Yes Performance Sewing Machine Accuracy Requirement Conforming To Is 7491 Yes Sewing Requirements Conforming To Is 7492 Yes Durability Requirements Onforming To Is 7493 Yes Other Requirements Nickel Plus Chromium Plated Parts Conforming To Service Condition 1 With Designation Fe/Ni/0Bcr R Of Is 1068 Yes Lubrication Orifices Yes An Automatic Thread Tension Release Yes Sewing Machines Components Conforming To Is Pecifications At Annex B To Is 1610 Latest Yes Accessories Supplied With Each Machine In Service Ox(Interchangeable With Machine Of The Same Make And Model) A) One Oil Bottle Filled With 50Ml Oil Min B) Two Screw Drivers (Engineering),One Large And One Small C)Three Bobbins D)Three Needles E) One Embroidery Plate (Where Drop Feed Arrangement Is Not Provided) F) A Booklet Containing Manufacturer S Operating Instruction And Technical Characteristics G) Spool Pin Pad Or Felt Washers (4 Nos) H) Needle Threader Yes Packing Packing In Accordance With Is 8355 Yes Warranty (Years) 1 , Sanitary Napkin Disposal Machine Specification Type Wall Mountable Purpose Burn Used Sanitary Napkins To Sterile Ash And Stop Automaticallycolor Elephant Greyoperation Mode Electronically Operated, Fully Automatic Loading Type Front Loading Stand Provided No Number Of Chambers Two Trap Door Available Yes All Ms Parts Powder Coated Yes Spare Parts Should Be Available For Minimum 5 Years From Date Of Supply Yes All Electrical Parts Are Isi Marked Yes Dimensions Of Main Unit Thickness Of Thermal Insulation Material (Mm) 40 Millimeter Thickness Of Ms/Ss Sheet Of Housing Cabinet (External) (Mm) 1.2 Millimeter Thickness Of Ms/Ss Sheet Of Burning Chamber (Internal) (Mm) (Min) 5 Millimeter Machine Width(Mm) 200-300 Machine Depth (Mm) 201-300 Machine Hight(Mm) 200-500 Machine Weight(Kg) 16-30 Door Width(Mm) 101-150 Door Height(Mm) 101-150 Thickness Of Door (Mm) 25 Millimeter Internal/Burning Chamber Shape Vertical Cylindrical Flexible Emission Outlet Pipe Dia (Mm) 25 Millimeter Detachable Ash Tray Length (Mm) 100-150 Detachable Ash Tray Width (Mm) 151-200 Detachable Ash Tray Height (Mm) 5-15 Stand Height (Mm) 500 Millimeter Stand Width (Mm) 200-300 Stand Depth (Mm) 201-300 Material Of Machine Unit Material Of Housing Cabinet (External) Mild Steel(Crca) Sheet Material Of Burning Chamber (Internal) Mild Steel(Crca) Sheet Finish Of Ms Parts Of Cabinet Epoxy Anti Rust Proof Painting For Superior Finish Material Of Thermal Insulation High Density Ceramic Fiber Sheet Constructional Features Thermal Insulation Of Burning Chamber Housed In Outer Chamber Yes Burning Chamber Tray Provided Yes Emission Outlet Pipe Location Top Of Machine Means Of Connecting The Unit Outlet With Flue Gas Emission Pipe Flanged Type Of Door Lock Provided Latch Lock Control & Functional Features Temperature Indicator Provided Yes Timer Provided Yes Auto Cut-Off Temperature Display Yes Digital Display To See Actual And Set Temperature Yes Minimum Burning Temperature (Degree C) 800 Burning Capacity Per Day (Number Of Napkins) 200-500 Burning Capacity At A Time (Number Of Napkins) 1-15 Residue Ash Per Napkin (Gms) 1 Gram Burning Time Of Full Capacity Napkins/Pads (Minutes) 10 Minute Skin Temperature Of The Unit Under Operation (Deg C) 0-15 Installation, Training, Demonstration And Plumbing Included Yes Electrical And Safety Features Automatic Digital Controller For Time Yes Automatic Digital Controller For Temperature Yes Equipment On/Off Indicator Provided Yes Power Supply 230V +/-10%, 50Hz, Single Phase, Ac Supply Electrical Power Consumption(Watt) 500-1000 Minimum Length Of Power Chord To Be Supplied Along With Machine (Mtr) 2 Meter Type Of Heater Ceramic Heater Containing Coil Power Saver (Auto Power Cut-Off) Yes Safety Mcb Provided (16A To 30A) Yes Protection Against Electric Shock When Checked As Per Is:302-1/2008 Yes Minimum Insulation Resistance (Ir) At 500 Vdc (Mega Ohm) 2 Maximum Electrical Insulation And Leakage Current As Per Is:302-1/2008, (Ma) 0.21 Maximum Earthing Continuity Test When Tested As Per Is:302-1/2008 (Ohm) 0.1 Hv Test At 1000 V Rms For 1 Sec When Tested As Per Is:302-1/2008 No Reakdown Shall Occur During The Test Smoke Control Unit (Scu) Type Of Scu (Smoke Control Unit) Top Mounted Material Of Housing Of Smoke Control Unit (Scu) Mild Steel(Crca) Cabinetfinish Of Ms Parts Of Scu Cabinet Epoxy Anti Rust Proof Painting For Superior Finish Overall Height Of Scu (Mm) 300 Overall Width Of Scu (Mm) 301-500 Overall Depth Of Scu (Mm) 100-300 Number Of Chambers For Filteration Of Smoke Emission Two Both Carbon Control And Foul Odour Control Chambers For Filteration Of Smoke Emission Yes Number Of Filters In Carbon Control Chamber One Type Of Filters In Carbon Control Chamber Steel Mesh Filterr Number Of Filters In Odour Control Chamber One Type Of Filters In Odour Control Chamber Activated Carbon Filterblower Type Centrifugal, Direct Driven Blower Rpm 1800 Power Supply Of Spu 230V +/-10%, 50Hz, Single Phase, Ac Supplyminimum Length Of Flexible Emission Outlet Pipe To Be Supplied Along With Machine (Mtr) 3 Cost Of Additional Flexible Emission Outlet Pipe, If Required On Actuals To Be Paid By The User Yes Emission Standard For Smoke Conformity To Cpcb, Min Of Environment & Forests Standard Hazwams/30/2005-06 Yes Particulates (Half Hourly Average) (Mg/Nm3) (Max) 50 Hcl (Half Hourly Average) (Mg/Nm3) (Max) 50 So2 (Half Hourly Average) (Mg/Nm3) (Max) 200 Construction Of (Half Hourly Average) (Mg/Nm3) (Max) 100 Construction Of (Daily Average) (Mg/Nm3) (Max) 50 Total Organic Carbon (Half Hourly Average) (Mg/Nm3) (Max) 20 Hf (Half Hourly Average) (Mg/Nm3) (Max) 4 Nox (No And No2 Expressed As No2) (Half Hourly Average) (Mg/Nm3) (Max) 400 Total Dioxins And Furans ( 6 To 8 Hours Sampling Basis, Please Refer Guidelines For 17 Concerned Congeners For Toxic Equivalence Values To Arrive At Total Toxic Equivalence) (Ng Teq/Nm3) (Max) 0.1 Cd + Th + Their Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.05 Hg And Its Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.05 Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+Their Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.5 Loss On Ignition (Max) (% Dry Weight Of The Material) 5 Packing Packing Carton Box Marking And Instructions The Appliance Is Marked As Per Is:302-1/2008 Yes Certification Submission Of Test Report From Central Government /Nabl/Ilac Accredited Lab Specifically Containing Electrical & Electronic Parameters, Thermal Insulation Material Of Burning Chamber Etc In Addition To The Declared Specification Parameters At The Time Of Supply Yes Submission Test Report For Equipment For Compliance Of Flue Gas Emission And Ash Upon Combustion Of Sanitary Napkins/Pads To Central Pollotution Control Board (Cpcb) Norms From Nabl Accredited Lab At The Time Of Supply Yes Certification Available Eu-Cecertificate For Manufacturing Premises Available Iso Compliance Certificate Is To Be Furnished After Conducting Comprehensive Performance Test By The Supplier Yes Submission Of All The Certifications To The Buyer Along With Supplies Yesperformance Requirements Warranty (Yrs) 1 , Fully Automatic Coin Operated Sanitary Napkin Vending Machine -100 Pads Specification Sms Notification By Machine Yes Type Of Machine Automatic Type Of Fitting Wall Mountable Color Others Napkin Size For Loading Any Size Napkin Fold Trifoldoperating Features Coin Operated Multiple Coins Accepted Yes Number Of Napkins/Pads Provided/Loaded With The Vending Machine 4 Multiselection Of Napkin Type No Number Of Selection Options 1 Vending Option Vertical Accessibility For Free Vending Utility Service Na Type Of Loading Spiral Less Vending Napkin Individually Packed Yes Led Illumination Provided For Visibility Of Napkins In The Machine No Visibility Window No Pre-Programmable Facility Available Yes Maximum Storage Capacity (Nos)(Nos) 75-100 Digital Counter For Accounting No No Stock Message Display Available Yes Built-In Program For Automatic Coin Return/Reject System When There Is No Stock Or No Power Yes Built-In Program For Automatic Currency Block/Reject System When There Is No Stock Or No Power Yes Built-In Price Programming Software For Changing The Price Yessales Data Retrieval No Any Additional Built-In Features Available When There Is No Stock, Coin Will Not Be Accepted ,Shock Proof,Light Weight & Compact Design Functional Features Material Of The Outer Body Mild Steel(Ms)Type Of Battery Sealed Maintenance Free Lead Acid Built-In Charger No All Ms Parts Are Duly Painted By Powder Coating Mode Of Function Stand Alone Operating Power Source Electronic Input Power Supply 220V +/- 10%, 50Hz, Single Phase Ac Battery Backup Available No Battery Backup Time (Hrs) Na Power Consumption(Watt) 8 Dimensions Width (Mm) 200-400 Depth (Mm) 100-200 Height (Mm) 800-1000 Weight (Kg) 10-20 Thickness Of Ss/Ms Sheet (Mm) 1.2 Thickness Of Frp/Plastic Sheet (Mm) Na Warranty 0Ne Year , Sanitary Pads Specification Napkin / Pad Consists Of Outer Covering With Sufficient Number Of Channels For Leak Protection Yes Type Of Napkin Large Tabless Napkin / Pad Shall Have A Non-Absorbent Barrier On One Side Which Shall Have An Identifying Hread Or Marking Indicating Clearly The Side Of The Barrier Yes Adhesive Back Strip Yes Color Of Pad White Soft,Comfortable,Breathable,Odorless , Anti-Bacterial , Non-Allergic And Bio-Compatible,Bio-Degradable Yes Ph Of The Absorbent Material Of The Napkin As Per Is : 1390-1961 Yes Absorbency With Prescribed Fluid @50 Ml/Min Instead Of 30 Ml Of Cl 5 (1) Of Is : 5405/1980 (First Revision) Reaffirmed 2012, With Amendment 1, Without Leakage On Bottom And Sides Yes Disposability - Disposable Napkin /Pad With Covering Removed Shall Dis Integrate In The Water In Not More Than 5 Minutes When Immersed In 15 Litres Of Water And Stirred Yes Instructions Indicating Removal Of Non-Absorbent Barrier Before Flushing Of Napkin Yes Standard Conformity To Indian Standard Is: 5405-1980(Latest) Except For Absorbency And Size Yes Product Is Bis Marked No Cm/L No(If Product Is Isi Marked) 0 Dimensions Size Of Napkin (Length X Width X Thickness) (In Mm) (200+-10)X (75+-5) X (10 +-1.5) Weight Of Single Pad (In Grams) 9+-1 The Thickness Of The Pad Shall Be Average Of The Height Measured By Stacking 10 Complete Pads Yes Napkin / Pad Should Have Uniform Thickness Throughout Without Any Wrinkle Or Distortion Yes Material Material Of Inside Cover Rayon Absorbent Filler Material Cellulose Pulp Absorbent Filler Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material Yes The Covering Of The Absorbent Filler Shall Be Of A Good Quality Poly-Perforated Film Sleeve, Gauze Or Non-Woven Fabric With Sufficient Porosity To Permit The Assembled Pad To Meet The Absorbency Requirement Yes If Cotton Gauze Is Used For Covering Of The Absorbent Filler, It Shall Conform To Is 758-1975 Na Packing And Marking Primary Packing (No Of Pads In A Pack) 6 Type Of Primary Packing Polyethylene Bags Of Qualitative Material With Gsm 35-40 Printing On Primary Packing Include Logo In Four Colours Using Weather Proof Ink, Name, Manufacturers License No, Address, Length, Dimensions, Lot/Batch No, Date, Month And Year Of Manufacture, Date, Month And Year Of Expiry, Number Of Napkins, Advice For Storage And Any Other Printing Details Required By The Buyer As Per His Requirement Yes Secondary Packing Corrugated Box Of 5X120gsm Number Of Primary Packages In Secondary Package 125 Printing On Secondary Packaging Shall Include Generic Name Of Product, Lot/Batch No, Date, Month And Year Of Manufacture, Expiration Date, Month And Year, Manufacturers Name And Address, Consignee Address, Number Of Primary Packages, Gross Weight, Instructions For Storage, Disposal Instructions, Method Of Use And Indication As To Which Side Is Absorbent Etc And Any Other Printing Details Required By The Buyer As Per His Requirement Yes Ertifications Submission Of Form Central Govt/Nabl/Ilac Accredited Lab To Prove The Conformity To Declared Specification At The Time Of Supply Yes Certification Available Na , Ambu Bag General Type Self Filling With Air Usage Adult Utility Such As Clinic, Hospital, Ambulance Etc Clinic, Hospital Size Medium Colour Of The Bag Green Transparent Yes Flexible And Durable Yes Reusable Yes Autoclavable Yes Manual Resucitator Or Self-Inflating Bag Or Reservoir Bag For Positive Pressure Ventillating Yes Low Resistance Non-Breathing Expiratory Valve Available Yes Type Of Expiratory Valve Polysulphone Pressure Limiting Valve Available Yes Type Of Pressure Limiting Valve True Dimensions Maximum Bag Volume (Ml) 1000 Milliliter Length (Mm) 125 Millimeter Outer Diameter (Mm) 75 Millimeter Weight Including Patient Connector (Gms) 190 Gram Material Material (Medical Grade, Latex-Free, Non-Toxic, Non-Allergic And Antistatic) Silicon Rubber Functional Application Temperature 20 Deg C To 50 Deg C Yes Storage Temperature - 40 Deg C To 70 Deg C Yes Re-Breathing Bag Should Have An Expiratory Resistance Of 2 Point 2 Cms Of Water Yes Re-Breathing Bag Should Have An Inspiratory Resistance Of 3 Point 3 Cms Of Water Yes Re-Breathing Bag Should Have Controlled Flow Rates And Ventillation And With Reduced Airway Pressure Yes Port Available In The Bag To Connect With Oxygen Reservoir Yes Patient Connector Available Yes Type Of Patient Connector Psu And Silicon , 3 Seater Bench Steel Hevy Type Of Seating Separate Seat And Backrest Style With Arm And Backrest Seating Capacity (Nos) 3 Number Of Arms (Nos) 2 Delivery Status Knocked Down Supply To Be Assembeled By Seller On Site Seat Cushion Without Cushion Backrest Cushion Without Cushion Material Material Of Main Frame Mild Steel Material Of Seat And Backrest Mild Steel Material Of Arms Armrest Are Made Up Of Powder Coated High Pressure Aluminium Dye Cast Material Of Legs Powder Coated High Pressure Aluminium Dye Cast Legs Material Of Side Bar Bracket Made Up Of Chrome Plated Solid Steel Thickness Of Material Of Main Frame In Mm 1.8 Thickness Of Material Of Arms In Mm 1.5 Type Of Bolts M12 Bolts Thickness Of Pu Foam For Seat And Backrest ±2(Mm) N.A Density Of Pu Foam For Seat And Backrest ±2(Kg/Cubic Metre) N.A Covering Material For Seat And Backrest Na Dimension Overall Length In Mm (±10 Mm) 1840 Overall Depth In Mm ( ±5 Mm) 750 Overall Height In Mm (±5 Mm) 800 Seat Height From Floor In Mm (±5 Mm) 500 Mm Thickness Of Material Of Seat And Backrest (Mm) 1.2 Mm Certification Conforming To International Standard For Public Seating (*Bifma X 5 Dot 4 Or Equvalent) Yes Colour & Finish Colour Of Covering Material N.A All M S Strucure Finish Powder Coated Colour Of Paint Silver All Steel Component To Be Epoxy Powder Coated 50 Micron Thick Warantee Warantee Period In Number Of Years 1 Misc Seat And Backrest Are Perforated Yes Adjuster For Legs Yes Arms Chrome Plated Yes Legs Chrome Plated Yes Cushion On Arms No , Cushion Chair Tube Thickness - 1 Mm Tube Diameter - 16 Mm Weight: 5 Kg To 5.5 Kg Seat Material: Rexine Body Material: Steel Seat Color: Any Type Of Product: Visitor Chair Without Arms Style: Modern Primary Material: Metal Dimensions: 23 (L) X 21 (W) X 30 (H) Inch , Two Way Board One Side Black Board And One Side White Board With Magnetic Alphabets And Numbers , T-Shirts For Boys -Specification Utility: Unisex, Leeve Length ( Large Half Sleeve ), Depth Of Hemming/Binding At Neckline, Sleeve End And Bottom Binding 3 Cm, Material: Material ( Composition ), Polyester-42± 2%, Cotton-53± 2% And Lycra- 5± 1% ,Mass Of Material (G/ M²) 200 Gram, Knitting Interlock Knitted, Count Of Yarn (Ne) Double, Ph Value Of Aqueous Extract 6.0 To 8.0 ( Hot Method, As Per Is: 1390 ), Neck Binding / Collar Self Material, Bottom Hem ( Bottom Binding ) Self Material , Sleeve End Binding Self Materiallining Without Lining /Lining , Material 100% Polyester Mesh Mass Of Lining (Gram Per Square Meter) Not Applicable, Netting Mesh No Of Holes On Base & Bias Within 625 Square Millimeter Not Applicable Colour Of Mesh Lining Not Applicable Pattern Neck Type With Collars And Buttons Sleeve Type Set In Sleeve Full Sleeve Number Of Buttons In T Shirt With Collar Not Applicable Side Slit Without, Depth Of Side Slit ( In Case Of T Shirt With Side Slit) (Cm) Not Applicable Pocket Without Pocket, Size And Position Of Pocket ( In Case Of T Shirt With Pocket ) ( Width X Depth ) Not Applicable Stitching Sewing Thread 125 D Tex X 3, Polyester, Raw Edges, If Any Shall Be Bound By Overlock Stitching Yes Stitches Per Dm ( Min ) 36 Colour Colour As Per Buyers Requirements Colourfastness Of Fabric And Departmental Logo Colourfastness To Washing [Is/Iso 105-C10, Test- C (3)] Change In Colour - 4; Staining Of Adjacent Fabric - 4 Colourfastness To Perspiration ( Is 971 ) 4 Colourfastness To Rubbing ( Is 766) Dry - 4 / Wet - 4 Colourfastness To Light ( Is 2454 ) 5, Colour Fastness - Potential To Phenolic Yellowing Of Fabric 4 ( Test Method - Iso 105-X18:2007, Latest) Colourfastness To Washing ( Is/Iso 105-C10, Test- C (3))- Mesh Lining Change In Colour- 4; Staining Of Adjacent Fabric- 4 Colourfastness To Perspiration ( Is 971 )- Mesh Lining 4 Other Requirements Pilling Resistant [After 5 Hours Test As Per Is 10971 (Part 1)], Min 4 Dimensional Stability To Washing, Shrinkage Or Elongation Percentage, Max ( Is 2977 Latest), In Lengthwise And Width Wise Direction 3, Spirality, Percentage, Enumerable +/- 4 N/A Mandatory Max ( After One Wash ) ( Is/Iso 16322-1:2005 ) ( Washing As Per Iso 6330- 2A At 60 Degree C ±4, Label Tagless Logo And Marking Logo Marking As Per Grampanchayat / School/Anganwadi Requirements, Type Of Logo Embroidery Embroidery Thread For Logo Rayon , Pants For Boys -Specification Description Pants (Full Pants) For Anganwadi, Preschool,School Children/Boys Utility Utility Boys Size Size Large ( 0 To 18 Yrs ) Dimensions And Pattern Dimensions And Pattern As Per Sketch And Dimension Chart For Icds Pre-School Uniforms- Shorts For Children Of Anganwadi Centers In Gujarat, Furnished By Commissioner Of Women & Child Development, Gandhinagar, Gujarat ( Uploaded For Reference) Sketch And Dimensional Chart For Pre School Uniform- Shorts Has Been Seen And Understood Yes Material Fibre Composition (Warp & Weft) Polyester Staple Fiber (Psf) - 70% And Viscose - 30% (Tolerence ± 5%) ( Test -Method Is: 3416 , Part - 1 ) Count Of Yarn, Warp (Ne) 2/40S (Tolerence ± 5%) ( Test Method - Is: 3442 ) Count Of Yarn, Weft (Ne) 2/40S (Tolerence ± 5%) ( Test Method - Is: 3442 ) No Of Threads, Warp ( Ends Per Inch ) 64 (Tolerence + 5% / - 2.5%) No Of Threads, Weft ( Picks Per Inch ) 52 (Tolerance + 5% / - 2.5%) Mass ( Gram Per Sq Mtr ) 140G To 150G ( Test Method - Is : 1964 ) Weave Plain Stitching Sewing Thread 125 D Tex X 3, Polyester Stitches Per Dm 35 To 40 Raw Edges, If Any Shall Be Bound By Overlock Stitching No Colour Colour Any Other Colour As Per Buyers Requierment Colour Fastness To Light Change In Colour 4 Or Better ( Test Method - Is : 2454 ) Colour Fastness To Washing Change In Colour 4 Or Better , Stain On Adjacent Fabric 3 - 4 Or Better ( Test Method - Test C (3), Is / Iso 105 - C10 ) Colour Fastness To Perspiration Change In Colour 4 Or Better , Stain On Adjacent Fabric 4 Or Better ( Test Method - Is : 971 ) Colour Fastness To Rubbing Dry 4 Or Better , Wet 3 Or Better (Test Method - Is : 766 ) Other Requierments Pocket 2 Side Pockets Waist Band The Shorts Should Have Elastic For Full Portion Of Waist Band Logo And Marking Logo Marking No Type Of Logo Not Applicable Number Of Logos Not Applicable Size, Design And Location Of Logo As Per Buyers Requirement Yes , Socks For Boys And Girls -Specification Product Description Socks Nylon For Gents, Ladies And Childrens (As Per Indian Standard Is: 5084: 1990: Latest) Size Medium (As Per Ind) Colour Colour Other Colors As Per Buyers Requirement Other Colors As Per Buyers Requirement Yes Construction Type Of Knitting Fancy- Knitted (As Per Is Specification) Pattern Of Stitches (Only For Rib And Fancy Knitted Socks As Per Is) Na Kintting Structure Single Cylinder Heel And Toe Single Heel And Toe Top Of The Socks Plain Knitted Diameter Of Machine (Mm) (As Per Is) (Mm) Gauge Of Machine (As Per Is) (Number Of Needles/ Inch) 12 To 14 , Shoes For Boys -Specification Closure Velcro/Less/Slip On Care Rub Gently With A Damp Cloth And Mild Soap Occasion Formal Outer Material Pvc Sole Material Pvc Colour Black Unisex For Boys A Type Shoes Shoe Width: Medium Material Type: Synthetic Lifestyle: Casual , Shoes For Girls -Specification Closure Strap/Slip On Care Rub Gently With A Damp Cloth And Mild Soap Occasion Formal Outer Material Pvc Sole Material Pvc Colour Black Unisex For Boys A Type Shoes Shoe Width: Medium Material Type: Synthetic Lifestyle: Casual , Desk Bench Fibre For Kids Product Description Colorful Study Table For Childrens. Study Table Comes With Vibrant Colors And It Is Made Of Safe Plastic Material.With This Desk Get An Learning And Educational Feel In Atmosphere.Key Features This Table And Chair Combo Is Perfectly Sized For The Kids It Is Made Of High Quality Plastic Material, Which Is Safe And Durable. Kids Will Love To Sit And Study On The Intellect Desk Specifications Brand - Playgro Toys Type - Desk And Chair Set Carrying Capacity - Up To 20 Kg Color - Red Yellow Dimensions - 71 X 73.5 X 62.2 Cm Age - 3 To 8 Years Material - Plastic Items Included 1 Desk And Chair Set , Metal Tricycle Garbage Rickshaw Color Green, Blue, Etc Capacity 480Kg Type Garbage Length 1280 Mm , Lagori Set Material Type(S) Wood Color Multi Item Weight 499 G Package Dimensions 26.5 X 9 X 7.9 Cm With Rubber Ball , Cricket Bat Standarad , Cricket Ball Standarad , Stump Set Standarad , Skipping Rope Standarad , Badminton Set Standarad , Football Standarad , Volleyball Shape Shape Of Volleyball ( When Inflated ) Spherical Dimensions And Mass Circumference 65 Centimeter Weight 260 Gram Material Material Of Case ( Outer ) Synthetic Leather Thickness Of Material Of Case 2 Millimeter Material Of Inside Bladder Rubber Material Of Bladder If Other Than Rubber False Stitching Thread Linen Stitching Thread As Per Is 417 Part 2 Any Other Stitching Thread As Per Buyers Requirements Yes , Volleyball Net Mater+B14ial Of Net Cord Cotton Breaking Strength Of Cord As Per Is 3345 Not Applicable Circumference Of The Cord Of Net 9.5 Millimeter Rope/ Cord To Tie With Post On Both Sides Nylon Breaking Strength Of Rope/ Cord ( Min ) As Per Is 3345 Not Applicable Material Of The Band At Top, Bottom And Sides White Canvas Material Of Flexible Cable Inserted In The Top Band To Fasten The Net To Posts And Keep Its Top Taut Na Dimensions Length Of Net 9.5 Meter Width Of Net 1 Meter Width Of The Two Fold Band At Top 7 Centimeter Width Of The Two Fold Band At Bottom Through Which A Rope Is Threaded 5 Centimeter Width Of Two- Fold Side Band 5 Centimeter Length Of Net On Each Side Of Side Bands 25 Centimeter Size Of Mesh Size Of Mesh ( Square ) Max 10 Centimeter Colour Colour Of Net As Per Requiremetn , Flying Ring Concept Of Toy This Light Weight Toy Provides Endless Variety Of Activities And Games To Children Configuration Having Flying Disc - Upper Side Of The Disk Imbossed/Engraved With Number/Alphabet/Picture (To Attract The Child) : As Reference Representative Image Uploaded Colour Of Flying Disc Any Style Of Upper Side Of Disk Engraved Upper Disk Designed (Embossed / Engraved) With N.A Approval Of Advance Sample Before Bulk Supply No Advance Sample Material Plastic Fruits And Vegetables Made Up Of Non Toxic Virgin Plastic Virgin Polyethylene Terephthalate Dimension & Mass Approximate Outer Diameter 300 Mm Approximate Weight Of Flying Disc 190 Gms. Colour-Finish & Packing Made-Up Ingredients Should Not Be Harmful To Kids Yes Colour And Finish (Other Indeterminable Parameters) N.A The Complete Set Should Be Properly Packed That It Should Not Damage During Transit Yes Flying Disk Big Should Not Have Sharp Edges Or Corners (Safety Point Of View) Yes , 1 Pairs Dandia Sticks For Traditional Games In School/Anganwadi(Multicolor) (14 Inch) Product Specification Name Of The Product Category Wood Crafts / Wood Carving Name Of The Subcategory Wooden Handicraft Name Of The Product Dandiya For Garba Ku Code Sku Code 390 Description Description 1 Pair Dimensions Dimensions ( Mm ) 14 Inch Mass Mass Material Material Wood , Side Drum , Javelin Stick(Bhala Normal)Dimensions Length Of Antenna 1.8 Meter Diameter Of Antenna 10 Millimeter Colour Colour Of Antenna Antenna Is Marked With 10 Cm Stripes Of Red And White Colour Alternatively. Standards And Certifications Product Generally Conforming To Is 3345- 1989 Latest No Product Confirming To International/ National Federation Requirements Like International Volleyball Federation ( Fivb )/ Volleyball Federation Of India ( Vfi ) Yes Certification From International/ National Federations Like International Volleyball Federation ( Fivb )/ Volleyball Federation Of India ( Vfi ) Yes Date Upto Which Certification Is Valid No Warranty Warranty 1 Year Advance Sample Agree To Provide Advance Sample(S) For Buyers Approval Before Commencement Of Supply Yes , Shot Put (Gola Normal) Utility Competition Material Of The Ball Cast Iron Mass And Diameter Of Shot Put- Competition Mass- 3.005 To 3.025 Kg, Diameter- 85 Mm To 110 Mm ( 3 Kg Shot Put ) Product Generally Conforming To Is 4386: 1988, Latest Yes Product Confirming To International/ National Federation Requirements That Is International Association Of Athletics Federations ( Iaaf )/ Athletics Federation Of India ( Afi ) Yes , Lezim 1 Piece Lezim / Lazium Equipment. Product Dimensions: 33 X 2 X 2 Cm Repeatedly Used In School Dance, Military And Other Organizations As A Fitness Drill Best Sports And Entertainment Tools For Exercise And Entertainment Purposes All Material Used Steel And Wire Is Broad And Plat Is Heavy Steel Number Of Puzzle Pieces 1 Batteries Required No Material Type(S) Wood & Steel Color Multi Item Weight 200 G Product Dimensions 6 X 6 X 33 Cm , Chess Set Description Chessboard With Chess Pieces Dimensions And Mass Size ( Length X Width ) Chess Board 32 Centimeter Size Of Square In Chess Board 4.5 Centimeter Mass Of Chessboard ( Gram ) 100 Pieces Total Chess Pieces Total 32 Pieces Are Used For Playing Chess. Each Player Has 16 Pieces: 1 King, 1 Queen, 2 Rooks, 2 Bishops, 2 Knights And 8 Pawns. Height Of Pieces King - 9.5 Cm, Queen - 8.5 Cm, Bishop - 7 Cm, Knight - 6 Cm, Rook - 5.5 Cm And Pawn - 5 Cm. (These Dimensions May Differ Up To 10% From The Above Recommendation, But The Order (E.G. King Is Higher Than Queen Etc.) Must Be Kept) Diameter Of Pieces Base 40-50% Of Its Height. Material Material Of Chess Board Cardboard Material Of Chess Pieces Hard Plastic Colour Colour Of Chessboard The Colors Of The 64 Squares Alternate In Colour I.E Light And Dark Squares. Colour Of Black Pieces Black Colour Of White Pieces Cream Other Requirement Strong And Durable Yes Style Of Pieces Staunton Foldable Type Yes Provision For Storage Of Chess Pieces In Chess Board Magnetic Attraction Between Chessboard And Pieces No , Carrom Board With Carrom Man, Striker And Powder Size 26X26 Shape Shape Of Carrom Board Square Playing Surface Of Carrom Carrom Playing Surface Material Lacquered Plywood Size Of Playing Surface (Side Of Square) 73.5 Cm To 74 Cm Thickness Of Playing Surface (Min) 8 Mm Carrom Playing Surface Is Waterproof Yes Surface Finish Completely Smooth (Carrom Board Shall Be Able To Have At Least Three And A Half Runs Of A Normally Smooth Striker Of 15 Gms Weight, When Struck With The Maximum Force, From One Of The Base Lines, To The Opposite Frame Of The Carrom Board.) Carrom Frame Material Of Carrom Frame Any Other Hard Wood With Good Resistance Carrom Frame Breadth 7.2 Centimeter Carrom Frame Height From Playing Surface 2.54 Centimeter Corners Of The Frame Corners Which Are Adjoining The Playing Surface Are Inside Curved Bracing Suitable Bracings Shall Be Provided Underneath The Playing Surface And Fastened With The Frame. Pockets Of Carrom Pockets At Four Corners Pockets Should Be Round Inwardly And 4.45 Cm In Diameter With Admissible Variation Of Not More Than 0.15 Cm Pocket Net Each Pocket Net Shall Have Capacity Of Holding At Least 10 Coins Marking On Playing Surface Of Carrom Board Base Line Two Straight Lines, Black In Colour, Of 47 Cm (± 0.30 Cm) Each In Length On All Four Sides Of The Playing Surface, Parallel To The Frame. The Lower Of These Two Lines, Which Shall Be Between 0.50 Cm And 0.65 Cm In Thickness, Shall Be 10.15 Cm Away From The Frame And The Other One 3.18 Cm Away From The Lower Part Of The Base Line. Base Line Circles The Base Lines Shall Be Closed By Circles Of 3.18 Cm In Diameter At Both Ends. Within This Circle A Portion Of 2.54 Cm In Diameter Shall Be Coloured In Red. These Shall Be Drawn So As To Touch Both The Base Lines And Also The Upper Base Lines Of The Adjacent Side When Imaginably Extended. The Distance Between The Base Circle On One Side And That Of The Other May Be 1.27 Cm Approximately. Arrows Four Arrows, Black In Colour, Of Not More Than 0.15 Cm Thickness Shall Be Drawn At Each Corner Of The Carrom Board At An Angle Of 45 Degrees To Any Of The Adjacent Sides And Each Of Them Shall Pass Through The Gap Between The Two Base Circles And Point Towards The Centre Of The Pocket Leaving A Clear Distance Of 5.00 Cm From The Edge Of The Pocket. The Length Of The Arrows Shall Not Exceed 26.70 Cm. A Decorative Arch Of 6.35 Cm In Diameter With Pointers At Both The Ends, Drawn At The Starting Point Of The Arrows Leading Towards The Pocket, Is Permissible. Centre Circle Exactly In The Centre Of The Carrom Board There Shall Be A Circle Of 3.18 Cm (± 0.16 Cm) In Diameter Drawn Black In Colour. Circle Shall Be Filled In Red Colour.Outer Circle A Circle Of 17.00 Cm (± 0.30 Cm) In Diameter With The Centre Point Of The Carrom Board As Its Centre, Black In Colour. Any Decorative Design In The Circle Is Permissible. , Rubber Ring Approximate Diameter Of Outer Ring 150 Mm Approximate Diameter Of Inner Ring 90 Mm Weight Of Ball With Tolerance Of (-) 10 Gms N.A Weight Of Ring With Tolerance Of (-) 10 Gms 100 Gms. , Wall Fantype Of Fan Mounting Bracket Mounted Fan For Wall Mounting, Method Of Mounting On Fan Base Oscillating, Type Of Fan Motor Non-Capacitor Type, Fan Size 400 Millimeter, Minimum Air Delivery (Cubic Meter/ Min) 65 For 400Mm, Maximum Input Power For Capacitor Type Fan (Watt) 61 For 400Mm, Maximum Input Power For Non - Capacitor Type Fan (Watt) 73 For 400Mm, Ingress Protection For Fan Motor And Regulators Ip 21, Generic Motor Type Ac Type Of Enclosure Of Motor And Regulator Ventilated, Class Of Insulation For Fan And Regulator Class Ii , Rated Voltage 220V Ac Speed Control Mechanism Pull Cord Or String Based Control , Rpm At Maximum Speed 1325, Number Of Blades 3 , Material Of Blade Aluminiums, Body Colour Any, Blade Colour Any ,Fan Guard Yes Fan Guard Material Powder Coated Metal Wire Number Of Speed Steps 3 Adjustable Vertical Tilt Yes Angular Movement 180 Degree, Length Of Cord With Suitable Plug Top (Inclusive In The Scope Of Supply) 2 Meter, Additional Features, If Any High Speed , List Of Items And Quantity Of Each Item Included In The Offer Wall Mounted Clip , Gas Bhatti Single Burner- General Fuel Type Lpg Material Body Material Stainless Steel(304) Leg Material Stainless Steel(304) Shape,Design & Colour Top Shape Square Number Of Burner 1 Regulator With Step In Regulator 1 Stove Leg Withleg Shape Square Pipe Stove Wheel No Number Of Wheel Na Wheel Brake No Finish Polished Dimensions Overall Length(In Mm) 300-320 Overall Width(In Mm) 301-320 Overall Height(In Mm) 300-320 Burner Diameter(In Mm) 50-60 Wheel Diameter(In Mm) 121-130 Ss Sheet Body Thickness(In Mm) 0.61- 0.7 Pipe Size(In Mm) Dia 20 Pipe Thickness(In Mm) 0.8- 0.9 Leg Height(In Mm) 41-50 , Desk Bench For Kid 6 To 10 Yrs Generic Type Of Desking Integrated Desk Cum Seating With Shelf / Storage Under Desk Desking Configuration Three Seater Length Of Desking, Seating And Backrest (If Provided) In Mm (±10 Mm) 1500 Desk / Bench Specifications Material Of Desk Top +/- 2 Mm (For Shelf / Storage +/- 4 Mm) 20 Mm Thick Mdf Board Of Grade Sbg Ii Conforming To Is 12406 Laminated With Minimum 0.6 Mm Thick On Top Side Of Type S, P Or F Having Index 3.2.3 Conforming To Is 2046 And Minimum 0.5 Mm Thick Balancing Laminate On The Other Side Material Of Support Structure Or Side Pannel Ss 202 Structure Height Of Desk Top In Mm (±5 Mm) 700 Width Of Desk Top In Mm (± 5 Mm) 400 Seating Specification Material Of Seat And Backrest (If Provided) (+/- 2 Mm (For Back Rest +/- 4 Mm) 20 Mm Hick Mdf Board Of Grade Sbg Ii Conforming To Is 12406 Laminated With Minimum 0.6 Mm Thick On Top Side Of Type S, P Or F Having Index 3.2.3 Conforming To Is 2046 And Minimum 0.5 Mm Thick Balancing Laminate On The Other Side Material Of Support Structure Ss 202 Structure Material Of Seat Cushion Without Cushion Width Of Seating In Mm (±10 Mm) 300 Height Of Seat In Mm (±10 Mm) 460 B193width Of Backrest If Provided In Mm (± 5 Mm) 280 Back Support For Seating Of Same Materail As Seating Provided Without Cushion Misc Design As Per Dgs&D Drawing No Dqa/Ge/Rc-208/Schedule 19 (Drg 1,2,3,4,5,6,7,8,9,10) Can Be Configured As Per Buyers Choice Within Offered Technical Details Colour Of Finish As Per Buyers Choice Desk Top Finishing Two Long Sides Shall Have Post Form Half Round Profile And Other Two Sides Edge Banded With 2 Mm Thick Pvc Tape With The Help Of Hot Melt Glue , Desk Bench For Kid 10To 16 Yrs Generic Type Of Desking Integrated Desk Cum Seating With Shelf / Storage Under Desk Desking Configuration Three Seater Length Of Desking, Seating And Backrest (If Provided) In Mm (±10 Mm) 1500 Desk / Bench Specifications Material Of Desk Top +/- 2 Mm (For Shelf / Storage +/- 4 Mm) 20 Mm Thick Mdf Board Of Grade Sbg Ii Conforming To Is 12406 Laminated With Minimum 0.6 Mm Thick On Top Side Of Type S, P Or F Having Index 3.2.3 Conforming To Is 2046 And Minimum 0.5 Mm Thick Balancing Laminate On The Other Side Material Of Support Structure Or Side Pannel Ss 202 Structure Height Of Desk Top In Mm (±5 Mm) 700 Width Of Desk Top In Mm (± 5 Mm) 400 Seating Specification Material Of Seat And Backrest (If Provided) (+/- 2 Mm (For Back Rest +/- 4 Mm) 40 Mm Hick Mdf Board Of Grade Sbg Ii Conforming To Is 12406 Laminated With Minimum 0.6 Mm Thick On Top Side Of Type S, P Or F Having Index 3.2.3 Conforming To Is 2046 And Minimum 1 Mm Thick Balancing Laminate On The Other Side Material Of Support Structure Ss 202 Structure Material Of Seat Cushion Without Cushion Width Of Seating In Mm (±10 Mm) 300 Height Of Seat In Mm (±10 Mm) 800Mm B193width Of Backrest If Provided In Mm (± 5 Mm) 280 Back Support For Seating Of Same Materail As Seating Provided Without Cushion Misc Design As Per Dgs&D Drawing No Dqa/Ge/Rc-208/Schedule 19 (Drg 1,2,3,4,5,6,7,8,9,10) Can Be Configured As Per Buyers Choice Within Offered Technical Details Colour Of Finish As Per Buyers Choice Desk Top Finishing Two Long Sides Shall Have Post Form Half Round Profile And Other Two Sides Edge Banded With 2 Mm Thick Pvc Tape With The Help Of Hot Melt Glue , Amplifire 800 Watt Power Output 1150W Rms Max., 800W Rms At 10%Thd, 770W Rms At 5% Thd 725W Rms At 2% Thd Output Regulation = 2Db, No Load To Full Load At 1Khz Input Channels 1 × Mic 1Mv / 4.7K?, 1 × Aux 100Mv / 470K?, 1 × Aux 250Mv / 20K?, 1 × Cd 250Mv / 20K?, 1 × Line 1V / 20K? Frequency Response 50Hz-18,000Hz ±3Db Signal To Noise Ratio 60Db Tone Controls Bass (100Hz) : ± 8Db, Treble (10Khz) : ± 8Db Line Output 1V/1K? Speaker Output 2O, 4O & 8O , Speaker Box 700 Watt Pairinput Power 700W Rms Configuration Two Way Frequency Response 40-20,000Hz Components 2 × 15 Lf Speaker, 16 × 7 Dynamic Hf Unit Special (1W/1M) 103Db Max. Rated Special 131Db Nominal Impedance 4O Crossover Frequency 2Khz Port Free Flow Flared Input Connectors 2 Nos. Of Speakon Sockets Dimensions W530 × H1210 × D510mm Weight 65.00Kg , Sound Mixer For Amplifier Power Requirement Ac: 220-240V 50/60Hz, Dc: 12V (1×12V Car Battery) Outputs 2 × Preamp 200Mv/600O, 4 × Line 1V/1K?, 1 × Headphone 120Mv@ 8O Frequency Response 20-20,000Hz (±3Db) Distortion 1% Signal To Noise Ratio 50Db Input Channels 12 × Mic 0.6Mv/4.7K?, 2 × Aux 100Mv/470K?, 1 × Aux 500Mv/100K? Tone Controls Bass: ± 10Db At 100Hz, Treble: ± 10Db At 10Khz Dimensions W350 × H145 × D200 Mm Weight 3.9Kg , Pa Music Horn Input Power 40W Rmspower Taps 40/20/10/5W Impedance 250/500/1K/2K? Frequency Response 120-16,000Hz Special At 1Khz 98Db/1W/1M; 114Db/40W/1M Dimensions W370 × H255 × D300 Mm Weight 6.5Kg Material Abs (Uv Protected) , Mice Stand Type Floor Stand Height 920-1500 Mm Base Dia 230 Mm Weight 4.41Kg , Wireless Mic Type Wireless Form Factor Collar (Lapel) If Wireless, Operating Range (Meter) 30 Meter If Table Top, Length Of Goose-Neck (Mm) 0 Millimeter Polar Pattern / Directionality Cardioid Microphone Transducer Type Condenser Inbuilt Speaker No Frequency Response (Hz) 20-20,000 Hz Equivalent Noise Level (Dba) 15 Signal To Noise Ratio (Db) 15 Electrical Impedance (Ohm) 0Sensitivity -50 Dbv/Pa (3.15 Mv)Led Indicator Availableon/Off Switch Availablevolume Control Yesaudio Connector Type Xlrcasing Material Plasticpower Source Acoperating Temperature Range (Degree C) 5 Operating Humidity (Rh%) 80Dimension (W X H X L) (Mm) 210 X 42 X 152Net Weight (Gram) 250 Gramwarranty (Years) 1 , Wired Mic Specificationtype Wired Form Factor Handheld If Wireless, Operating Range (Meter) 0 Meter If Table Top, Length Of Goose-Neck (Mm) 0 Millimeter Polar Pattern / Directionality Cardioid Microphone Transducer Type Dynamic Inbuilt Speaker No Frequency Response (Hz) 20-20,000 Hz Equivalent Noise Level (Dba) 14 Signal To Noise Ratio (Db) 12 Electrical Impedance (Ohm) 14 Sensitivity -54.5 Dbv/Pa (1.85 Mv) Led Indicator Not Available On/Off Switch Available Volume Control No Audio Connector Type Xlr Casing Material Plastic Power Source Dc Operating Temperature Range (Degree C) 34 Operating Humidity (Rh%) 34 Dimension (W X H X L) (Mm) Na Net Weight (Gram) 1.56 Gram Warranty (Years) 1 , Xlr To Aux 6.5 Mm Cable Xlr Female To 1/4 Ts Cable Is Made Of 100% 4N Ofc For Effective Emi And Rfi Rejection And Flexibility, Extremely Provide Low Fidelity Attenuation During The Long Distance Transmission. ?Hi-Fi Quality?: The Microphone Cable Has Double Shielding (High Density Bc Braid Shielded + Aluminium Foil) Can Provide High Stable Performance And Lowest Loss During The Transmission. Heavy Duty Alloy Metal & Gold-Plating Connectors Increase Durability , Anti-Oxidant, Plugging And Unplugging 6,000 Times To Deliver Pristine Sound. ?High Performance & Rohs Pvc?: The Furui Xlr Female To 6.35Mm 1/4 Ts Cable Has High Resistance Tensile Strength Rohs Pvc Insulation Improves High Frequency Response, Extreme Resistance To High And Low Temperature 14? - 572?(-10?-300?). ?High Strength Nylon Braid & Tensile Resistance Cotton Yarn Wrap?: Ours Microphone Cable Use High Strength Nylon Braided Support 20 - 25 Kg Pulling Force, High Resistance Tensile Strength Cotton Yarn Wrap Provides Amazingly Superior Clarity And The Highest Cancellation Of Noise And Rf Interference. And Ours Xlr Female To 1/4 Ts Cable Is Very Flexible, 23 Awg, Od 6.5 Mm (0.256 Inch), Can Bent 90 Degree. , Cymbal /Zanj Band Pair Cymbal Type Clash Cymbal Material Nickel, Silver Plated Size 20 Inch , Mop / Pocha Package Mop 1, Mop Head 2, Liquid Dispenser Mop Comes With Microfiber Mop Head Works Great Wet Or Dry Banded Strands Make The Mop Super-Absorbent Mop Cleans Easily Around And Under Furniture, In The Bathroom And Along Baseboards And Other Hard-To-Reach Places Keeps Your Hands Out Of Dirty Water Mop Head Disengages With Your Foot So Your Hands Never Have To Touch The Mess Handle Angle May Be Adjusted From 45 To 180 Degrees For The Most Comfortable Mopping Position Mop Head Is Machine , Nail Cuitter For Kids 0 To 12 Yrs Key Features: Stainless Steel Blunt Edge Avoid Hurting Your Babys Skin Easy To Clean Specifications Type - Nail Clipper Age - 2 To 4 Years Package Dimension - 12 X 7 X 5 Cm Product Dimension - 12 X 7 X 5 Cm Weight - 70 Gm Items Included In The Package 1 Nail Clipper The Baby Nail Clipper Are Made In Stainless Steel. It Has Curved Blade With Rounded Ends To Ensure Complete Safety During Use. They Come With A Cover To Hygienically Protect The Blades When Not In Use. The Front Part Of The Scissors Is Round Shape Designed. , Pencil Type And Grade Type Of Pencil General Writing Grade Hb Physical Properties Length Of Pencil (Mm) 177 No. Of Pencils In One Pack (Nos.) 10 Shape And Color Shape Of Pencil Hexagonal Body Colour Blacl Gray , Eraser-Soft And Smooth Erases Graphite Gently Without Damaging Paper Picks Up Dust While Erasing , Sharpner Body Material Plastic / Metal Blade Material Metal Blade Length (Mm) 10 Blade Width (Mm) 5 Diameter Of Sharpening Hole (Range) 9Mm-10Mm Sharpening Holes Singl , Type Ofregisters Plain Register Dimension Of Paper (Length X Width) (Mm X Mm) 148 X 210 Dimension Of Cover (Length X Width) (Mm X Mm) 160 X 215 Grammage Of Paper (Gsm) 70 Grammage Of Cover Paper (Gsm) 150 Brightness Of Paper (%) 72 Smoothness Of Paper (Bendtsen) (Ml/Min) 120 Opacity (%) 80 Number Of Pages 200 Type Of Binding Softcover Cloth Bound Content And Desciption General Format , Two Way Board (One Side Black And One Side White Board Inclidoing Magnetic Alphabets And Numbers) , Cob Web Brush Ape Of Brush Round & Curved Cobweb Brush Head Detachable Type Of Stick Telescopic Material Material Of Bristles Plastic Material Of Stick Plastic Dimensions Length Of Bristle (Mm) 100 Overall Length Of Brush Head (Mm) 225 Length Of The Stick (Full Open) (Mm) 2500 Overall Weight Of Cobweb Brush 170 , Wooden Speech Podium / Lecture Stand/Dias: Mode Of Supply Assembled Ready To Use Frame Type Free Standing Understructure Of Podium Gable End And Modesty Panel Storage No Storage Shelves Without Shelves Reading Surface Angled Surface Top Position Fixed Paper Stop No Wire Management Without Number Of Socket Box 0 In Built Sockets For Lan / Internet No Type Of Socket Box No Socket Box Material Podium Top Material Mdf Board Of Grade Sbg Ii Of Is 12406/Latest Gable End And Modesty Panel Material Flat Single Layer Prelaminated Mdf Board Conforming To Having Designation Plmdf-23 Of Is 14587/Latest Leg Material Teak Wood Misc Podium Top Long Sides To Be Post Form Half Round Profile With Corner Edge Bending Podium Top Plain Sides Edge To Be Banded With Pvc Tape Of 2Mm Thick With The Help Of Hot Melt Glue Gable End And Modesty Panel Plain Side N.A Number Of Buffers Provided N.A Dimension Thickness Of Podium Top ±2Mm 12 Millimeter Thickness Of Gable End And Modesty Panel ±2Mm 12 Millimeter Length Of Podium Top ±10Mm 600 Millimeter Depth Of Podium ±10Mm 500 Millimeter Height Of Podium ±10Mm 1100 Millimeter Presenter Side Height ± 10Mm 1050Mm Dimension Of Leg (Mmxmm) ±5Mm No Legs Shelves Width Of Shelves ±10Mm N.A Depth Of Shelves In Mm (±10Mm) Na Footrest Material Of Footrest Flat Single Layer Prelaminated Mdf Board Conforming To Having Designation Plmdf-22 Of Is 14587/Latest Length Of Footrest ±10Mm N.A Depth Of Footrest ±10Mm N.A Height Of Footrest (Front / Back) ±10Mm N.A Finish Of Exposed Edges To Be Banded With 0.5-1.0Mm Thick Pvc Tape With The Help Of Hot Melt Glue Material Thickness Of Footrest ±2Mm N.A Colour & Finish Podium Top Finish Laminate In Colour With Swede Finish 0.6-0.8Mm Thickness Of Type S,F Or P Having Index No.3.2.3 Conforming To Is 2046/Latest With Having Balancing Laminate Of 0.5Mm Thick On Other Sidetable Top Shade Peach Warranty Warranty Period In Number Of Years 1 , Pa Driver Units Weatherproof And Rugged Construction. High Spl, Crisp Penetrating Sound. Voice Coils Precision-Wound On An Aluminium Bobbin For Efficient Heat Dissipation. Degree Of Protection Ip 66 Provided, When Mounted On A Reflex Horn, Against Foreign Particles Such As Dust And Jets Of Water Thus Making Them Ideal For Outdoor Use. Meets En 60529.Input Power 60W Rms/90W Max. Impedance 16O Frequency Response 160-7,000Hz Special At 1Khz 113.5Db/1W/1M, 132Db/60W/1M Temperature Range -30°To + 70°C Throat Coupling 1-3/8 - 18Tpi, Throat Couple No.1 Dimensions Ø125 X H100 Mm Weight 2.05Kg Material Die-Cast Aluminium Acoustic Head (Flange) , Pa Trumpet Horn-Heavy Duty Aluminium Trumpet Is Ideal For Most Of The Large Outdoor Installations. Rugged Construction And Fitted With A Protective Pvc Ring On The Flare. Acoustically Well Designed, It Matches Ahuja Driver Units For An Efficient, Powerful And Clear Sound.Bell Dia 22 Cut-Off Freq. 160Hz Weight 2.27Kg , Amplifire Ideally Suited For A Wide Variety Of Music And Public Address Applications.6 Mic & 2 Aux Inputs.Built-In Mp3 Player With Lcd Display, Remote Control, For Usb, Sd/Mmc Cards.Preamplifier And Line Output For Connecting To A Booster Amplifier And For Recording The Programme.Line Input For Connecting The Output From Any External Mixer Or Permittingamplifire To Be Used As A Booster Power Amplifier Resettable Circuit Breaker For Protection Against Overload And Short Circuit.Instant Transfer To Dc Power (2Ã- 12C Car Battery) If Ac Power Fails.Box Speaker/Driver Unit Selector Switch. Bass Boost Defeated At Driver Unit Position For Safer Operation Of Driver Units. , Mic Microphone Cable 100M Material Plastic Branded Color Black Size 100M Power Source Electric Pack Type Box 2*(28/0.08Mm Bc+1/Tinsel Copper+1.75Mm Pvc)+Filling Cotton Yarn+Alp+112/0.08Mm Bc Braid +5.8Mm Pvc , Mic All Purpose Pa Microphone Reproducing Intelligible, Crisp And A Bright Sound. Suitable For Multi-Purpose Pa Installations. Supplied With Quick Detachable Holder With 3-Pin Professional Xlr Connector & 6 Mtrs. Twin Core Shielded Low Noise Cable. , P A Speaker ? 100 Watts ? Pa Speaker System ? A Compact Superior Quality Speaker System Comprising Of A Single 12 Full Range Dual Cone Speaker And A Piezo Horn Tweeter. The System Is Outstanding For Its Ability To Handle 100W Continuous Power With Undistorted Response And Is Ideal For Small Pa Applications. ? The Speakers Are Housed In A Rugged Closed Box Enclosure Made Of 18Mm Board, And Carpet Covered. ? 16.70Kg ? 12 Months Warranty , Mic Stand Microphone Stand Employ Sturdy Mechanism Ensuring Trouble Free Movement And Positioning Of Microphone. These Stands Are Functional And Resistant To Rust, Due To Superior Quality Of Chrome Plating/Powder Coating. Ahuja Stand With 5/8 27 Tpi To Match All Microphones.Type Floor Stand Height 920-1500 Mm Base Dia 230 Mm Weight 4.60Kg , Map 8 Nos Set As Following 1 Chikhali Taluka,2 Buldana District, 3 Maharashtra State, 4 India Country, 5 World Map, 6 Natural Map Of Maharashtra, 7 Social Map Of Maharashtra, 8 Political Map Of Maharashtra , Hand Held Digital Infrared Medical Thermometer For Measuring Body Temperature General Features Product Description Hand Held Digital Infrared Medical Thermometer For Measuring Body Temperature Purpose Infrared Thermometer Is A Quick And Easy-To-Use Method To Measure Body Temperature Suitable For All Age Group Product Information Type Of Thermometer Non Contact Infrared Thermometer Body Material Of Ir Thermometer Abs Color Of Device White Ergonomic Design Yes Temperature Display Unit Degree Celsius & Degree Fahrenheit Primary Measurement Mode Body Temperature Mode Measuring Site For Body Temperature Ear & Forehead Lowest Measurable Temperature For Body Mode 32°C (89.6°F) Or Lower Highest Measurable Temperature For Body Mode 42°C (107.6°F) Or Higher Accuracy Of Measurement For Body Temperature In °C (±) 0.2 Degree Celsius Accuracy Of Measurement For Body Temperature In °F (±) 0.5 Lowest Measurable Temperature For Room Temperature Mode 0°C (32 °F) Or Lower Highest Measurable Temperature For Room Temperature Mode 50°C (122 °F) Or Higher Sensor Type Thermal Sensor Display Resolution 0.1°C/0.1°F Response Time 1 Second Measuring Distance For Non Contact Type Ir Thermometer 5 Cm Or Better Number Of Recent Readings That Can Be Stored 10 Built-In Laser Pointer Weight Of Device With Battery 150 Gram Dimensions Of Device (Mm X Mm X Mm) 150X75x40 Display Display Type Lcd Display Backlit Display Yes Display Size 1.5 Inch Features Features Available Interchangeable Celsius & Fahrenheit Modes,Low Battery Indicator,Auto Power On,Trigger/Button For Operation,Auto Power Off When Not In Use,Display Of Previous Reading On Screen With Current Reading,Sound Indication When The Thermometer Is Ready To Take Or Show The Temperature,Audible Alarm For Fever,Different Backlight Colours To Differentiate Between The Fever Ranges,Silent Mode,Auto Hold Function,Waterproof Lens Easy To Clean And Disinfect,Data Transfer Facility Of Other Devices Through Usb/Bluetooth/Wifi/Rs 232,Limit Value For The Adjustable Alarm As Programmable Power Source Power Source Non Rechargeable Battery Battery Chemistry Li-Ion Battery Size, If Non Rechargeable Battery Aaa Number Of Batteries Required For Operation 2 Number Of Batteries Supplied (Inclusive In The Scope Of Supply) 2 Nominal Voltage Of Each Battery (V) 1.5 , Finger Tip Adult And Pediatric And Neonatal Pulse Oximeter Performance Parameters Type Of Pulse Oximeter Finger Tip Should Work During Motion And Very Low Perfusion Conditions Yes Special Signal Processing Technology (Motion Artifact Rejection) Nellcor Compatible Spo2 Probes Disposable Oxygen Saturation Range 0-100% Pulse Rate 25-240 Bpm Display Of Spo2 And Periodical Renewal Digital Display With Bar Graph Accuracy ± 5 % Type Of Patient Adult,Pediatric Should Be Shock Proof Yes Display (With Contrast Adjust-Ability) Lcd Display Should Be Readable From At Least 3 Feet Yes Saturation Displayed On The Screen No Pulse Rate Displayed On The Screen Yes Perfusion Index Displayed On The Screen Yes Status Of Battery Charging Displayed On The Screen Yes Sensor Off /On Status Yes Audible And Visual Alarms Yes Alarm Override Facility Should Be Present Yes Trends 72 Hrs Type Of Trend Display Graphical Data Interval In Sec 0 Power Source Battery Operated Automatic Switch From Mains To Battery In Case Of Power Failure Na Rs 232C Interface For Data Communication And Transfer Na Should Have Provisions For Wireless And Blue Tooth Connectivity Na Patient Extension Cable Not Provided Power Consumption In Watts 0 Operating Temperature Ambient Temperature Of 0 To 40 Deg C And Relative Humidity Of 15 To 90% Weight Of The Machine In Kg 10 Protective Splash Proof Case For Clean And Strogage And Safe Transport Provided No Length Of Power Cable Na Noise Level In Db 0 Display Must Allow Easy Viewing In All Ambient Light Levels Yes , Blood Pressure Machine Digital / Appratus Configuration Details Type Of Sphygmomanometers Or Blood Pressure Recording Unit: Digital Conformity To Indian Standrad For Sphygmomanometers Na For Digital Measuring Device Automated Type Portable Isi Marked Na For Digital Cm/L No And Validity Date Bp-(235)01 26/07/17 Measurement Method Oscillometric Display For Digital Bp Instrument: Lcd(Liquid Crystal Digital) Display Range: Pressure Measurement (Mmhg) 0 To 300 Range:Pulse Measurement For Digital With Accuracy &Plusmn; 5%. (Per Minute) 40 To 200 Accuracy:Pressure Measurement (Mmhg) +/- 3 Pressure Detection Capacitive Pressure Sensor Inflation Automatic Pressure Application By Pump Deflation And Rapid Air Release Automatic Pressure Release Valve Cuff Range Medium (22-32)Cm Dimensions Of The Equipment (Mmxmm) 400 X 80 X 90 Dimensions Of The Display Screen (Mmxmm) 59 X 43 Operating Temperature Range 0 To 55 Degree Celsius Stroage Temperature Range (-10) To 55 Degree Celsius Automatic Power Off If System Is Idle For 3 Minutes. Yes Weight (In Gram) 250 Power Power Source: Aa Size Chargeable Battery Set Type Of Aa Size Chargeable Battery (Aa Size) Lithium , Automatic Online Water Chiller 2 Ton Capacity Item Item Industrial Chiller Design No Of Door Single Position Of Door Top Opening Door Type Hinged Air Tight Door Yes No Of Shelves 0 Wheels No Visibility Of Item Stored No Type Of Insulation Poly Urethane Foam Method Of Defrosting Manually Deforested Type Of Cooling Direct Lock Yes Material Material Of Chamber Interior Abs Material Of Chamber Exterior Prepainted Sheet Door Material Polycarbonate Door Polycarbonate Window Door Cooling Coil Material Copper Instrument Temprature Controler Yes On/Off Switch Yes Storage Chamber Temprature Display Yes Audio Alarm Visual Alarm Digital Display No Visual Alarm Yes Digital Display Yes Capacity And Dimension Storage Volume(Net Capacity)(Liters) 1000 Over All Length(Mm) 1500 Over All Width(Mm) 1000 Over All Height(Mm) 1000 Insulation Thickness(In Mm) 60 Holdover Time(Minute) 60 Performance Eco-Friendly Refrigurator Yes Compressor Ac Reciprocating Compressor Set Temperature Range(Delta) 5 Minimum Achievable Temperature At 32 Degree Centigrade 8°C Green Refrigerants Yes Type Of Refrigerants R134a Voltage 220-240, Single Phase , 50 Hz Power Consumption(Kw/Day) 10 , Sink Hand Wash Station Item Stainless Steel Sink Built In Counter Uses Mess/School/Office And Other For Protection Against Covid-19 And Other Viruses Type Of Sink Built In Counter Stainless Steel Single Bowls Single Drain Board Sink Units Design Shape Of Sink Built In Counter Rectangle No Of Tap Holes 2 Design Feature In Stainless Steel Sink Built In Counter Tap Holes,Over Flow Holes,,Under Self Provided,Drainage Pipe Provided,Waste Jali Provided,Stiffener Provided Between Legs,Kitchen Unit Design Should Be Robust,Back Panel Above Table Provided,Three Side Panel Above Table Provided,Left Hand Side Drainage Provided,Right Hand Side Drainage Provided,Heavy Duty Rubber Shoe Dimension Length Of Counter(In Mm) 1200±10 Width Of Counter(In Mm) 700±10 Height Of Counter(In Mm) 900±10 Length Of Sink Bowl(In Mm) 450±10 Width Of Sink Bowl(In Mm) 500±10 Depth Of Sink Bowl(In Mm) 450±10 Length Of Additional Sink Bowl(In Mm) Na Width Of Additional Sink Bowl(In Mm) Na Depth Of Additional Sink Bowl(In Mm) ,Na Height Of Panel Above Counter 300±10 Height Of Panel Below Counter Na Thickness Of Stainless Steel Sheet(In Mm) 1.2 Thickness Of Sink Bowl(In Mm) 1.0 No Of Leg In Sink Built In Counter 6 Stainless Steel Structure Pipe Size 20 Dia Thickness Of Stainless Steel Structure Pipe 1.5 , Leg Operated Sanitizer Dispenser Or Foot Operated Sanitizer Dispenser Item Item Touchless Sanitizer Dispenser Type Of Dispensing Drop Mounting Type Wall Mounted Design Features Available In Touchless Sanitizer Dispenser Replaceable Liquid Bottle Sensing Range 0 - 4 Inch Rated Voltage 230V-50 Hz Material Body Material Of Touchless Sanitizer Dispenser Stainless Steel 304 Dimension Sanitizer Container Capacity (In Ml) 100-150 Dispensing Sanitizer Volume In One Use(In Ml) 10 , Sofa Set With Cushion 10Ft Material Frame Structure Material And Size (±1 Mm) Any Other Wood Of Minimum 25 Mm Thickness Seat Cusion Material Foam Density Of Cushion Of Seat Material ±3 (Kg/Cubic M) 40 Type Of Spring In The Base / Seating No Spring In The Base Generic Total Number Of Seats In The Sofa Set (Nos) 3 Type Of Sofa And Backrest Seat And Backrest Are Permanently Fixed With The Frame Structure Number Of Single Seater Units (Nos) No Single Seater Unit Number Of Two Seater Units (Nos) No Two Seater Unit Number Of Three Seater Units (Nos) 1 Number Of Four Seater Units (Nos) No Four Seater Units Frame Covering Fully Upholstered Sofa Set Is Foldable To Use As Bed No Backrest Cushion Material Foam Density Of Cushion Of Backrest Material (Kg/Cubic M) 40 Covering Material For Seat And Backrest Fabric Dimension Length Of Single Seater Units In Mm (±5 Mm) 750 Length Of Three Seater Units In Mm (±10 Mm) 3000 Depth Of Sofa Units In Mm (±10 Mm) 800 Sofa Height (Without Back Cushion) ±5 (Mm) 450 Millimeter Sofa Height (With Back Cushion) ±5 Mm 800 Millimeter Arm Width ±5 (Mm) 120 Millimeter Arm Height ±5 (Mm) 600 Millimeter Seat Height (With Seat Cushion) ±5 (Mm) 450 Millimeter Sofa Leg Height ±2(Mm) 75 Millimeter Sofa Leg Width / Diameter ±2 (Mm) 100 Millimeter Seat Cushion Length ±5 (Mm) 710 Seat Cushion Width ±5 (Mm) 510 Seat Cusion Thickness ±5 (Mm) 100 Backrest Cushion Length ±5 (Mm) 710 Backrest Cushion Width ±5 (Mm) 508 Backrest Cushion Thickness ±3 (Mm) 100 Thickness Of Foam In Arms ±2 (Mm) 50 Thickness Of Foam In Back ±2 (Mm) 76 Millimeter Thickness Of Foam In Front ±2 (Mm) 76 Millimeter Thickness Of Foam In Sides ±2 (Mm) 76 Millimeter , Wall Lamination, Decoration, Ply Running And Installation Per Feet Mdf, Paper Phenolic, Particleboard, Plywood, Baltic Russian Birch, Acrylic, Glass, Metal, Resin Panels:Thermally Fused Laminate (Tfl), Thermally Fused Melamine (Tfm), High Pressure Laminate (Hpl), Three Dimensional Laminate (3Dl), Wood Veneer, Translucent, Printed Graphic, Whiteboard, Chalkboard, Magnetic, Tackable With Installation And Its Regarding Feeting Materials Enter Rate In Running Sq Feet With Installation Feeting Chargesand Other Regarding Material , Wall Lamination, Decoration, Ply Running And Installation Per Feet Mdf, Paper Phenolic, Particleboard, Plywood, Baltic Russian Birch, Acrylic, Glass, Metal, Resin Panels:Thermally Fused Laminate (Tfl), Thermally Fused Melamine (Tfm), High Pressure Laminate (Hpl), Three Dimensional Laminate (3Dl), Wood Veneer, Translucent, Printed Graphic, Whiteboard, Chalkboard, Magnetic, Tackable With Installation And Its Regarding Feeting Materials Enter Rate In Running Sq Feet , Touchless Sanitizer Dispenser/Automatic Dispenser Item Touchless Sanitizer Dispenser Type Of Dispensing Spray Mounting Type Wall Mounted Design Features Available In Touchless Sanitizer Dispenser Built-In Sensor For Detection Of Hand,Waterproof,Battery Operated,Battery Cum Electric Operated,Anti-Interference,On/Off Button,Indicator Lamp,Speed Dispensing Of Liquid,Electric Adapter,With Battery,Liquid Filling Arrangement,Replaceable Liquid Bottle,Adjustable Dispensing Volume Sensing Range 0 - 4 Inch Rated Voltage Dc 6V,Dc 12V,230V-50 Hz Material Body Material Of Touchless Sanitizer Dispenser Abs Plastic Dimension Sanitizer Container Capacity (In Ml) 1001-1500 Dispensing Sanitizer Volume In One Use(In Ml) 5 , Flash Card 9.5 Cmx 1375 Cm (Alphabet/Fruit/Animal/Vegitable/Other) Set Of 5 Pcs , Small Board Book Set Of 5 - English - 2 To 5 Year (Domestic Aqua Animal/Birds/Wild Animals/Fruit/Vegitable/Abcd ) Any Set Of Five As Per Requirement , Abcd Chart Set Of 5 Pcs 65X55 Cm Aprrox Size (Abcd/Animal/Body Parts/Vegitable/Frouit/Animal Other) As Per Requirement , Basket Ball For Kids Type - Basket Ball Set Age - 3 To 8 Years Package Dimension - 33 X 25 X 13 Cm Ring Diameter - 14 Cm Ball Circumference - 38.5 Cm Weight - 174 Gm , Digital Infrared Thermometer Gun(High-Precision Infrared Sensor - Stable & Reliable Performance - Wide Temperature Ambience Adaptab) , Finger Tip Puls Oximeter ( Oxygen Level, Pulse Rate And Perfusion Index. It Has A Four-Colour Led Display With Adjustable Brightness And Comes With Signal Strength Display Feature.) , Fully Automatic Digital Blood Pressure Monitor( Fully Automatic Blood Pressure Monitor Operating On The Oscillometric Principle For Precise Measurements And Accurate Results. It Measures Your Blood Pressure And Pulse Rate With Easy One Touch Operation Cuff Size - Fits Arm Circumference (22-32Cm) The Device Uses Its Advanced Intellisense Technology For Comfortable Controlled Inflation Without The Need Of Pressure Pre-Setting Or Re-Inflation Even A Slight Pressure Change Can Be Detected Resulting Most Accurate Measurementalong With Blood Pressure Monitoring This Product Detects Irregular Heartbeat. It Is Loaded With Body Movement Indicator And Blinks If Your Systolic Or Diastolic Pressure Is Outside The Standard Range (Above 135 Systolic/85 Diastolic Mmhg)) , All In One Steam Vaporizer Machine For Cold And Cough With Nozzle Inhaler, Facial Sauna And Facial Steamer Machine For Adults And Kids , Hemoglobin Digital Monitor Accurately Detects Both Hb And Hct Levels Quick Hb And Hct Results Within 15 Seconds Simply Insert Strips, Apply Blood Specimen And Read Results Auto Calibration For Added Convenience No Specimen Preparation Required Low Maintenance And Quick Clean Up Urate Precise Result Equivalent To Automatic Hematology Analyser Only A Single Drop Of Fingertip Blood 10 Ul Sample Volume Required Wide Hb Measurement Range Of 5-25.6 G/Dl With Hct Range Of 15-75% Storage Maximum Test Results Portable Operated By Battery Or, Optional Ac Adapter Small And Handled For Immediate Diagnosis Ready To Use In Any Point Of Care Setting Dry Strips Hence Easy To Carry Anywhere , 3 Ply Face Mask Non Woven Disposable Face Mask Made Of Soft Non-Wove. Adjustable, Good Toughness, Good Nose Shaping, No Leakage. High-Quality Elastic Ear Loop, Stretching 19Cm, Suitable For Various Types. , 6-Inch Pre-Powdered Sterile Surgical Gloves-Box Of 50 Pairs Function:Anti-Smash, Anti-Heat, Anti-Cut, Arthritis Therapy, Anti-Static, Touch Screen, Anti-Vibration Material:Latex Aql 1.5 Colour:Blue, Violet, Black, White, Cobolt Blue Type:Powdered Or Powder Free Size:22*11*6, Xs/S/M/L/Xl Weight Of 9 Size:2.5Gsm-8Grms , Compressor Nebulizer Has An Attractive Wall-Mounting Design. The Body Is Made With Abs Plastic For Better Shock Absorption. Provides Anti-Vibration Feet. Doesnt Cause Much Noise. Comes With A Long Shelf-Life Compressor. Has An Attached Handle For Convenient Operation. , Blood Glucose Monitor With 10 Test Strips 1. Measurement Range: 1-33. 3Mmol/L 2. Blood Sample: Fresh Capillary Whole Blood 3. Blood Valume: 0. 5?L Small Blood Sample 4. Test Time: 5 Seconds 5. Operating Temperatuure: 10? To 35? 6. Automatic Alarm Clock Reminder 7. Date Management: 7, 14, 28, 60, 90 Days Averaging , Electrical Needle Syringe Destroyer/Needle Destroyer For Hospital And Laboratory Needle-Destroyers Minimize The Occurrence Of Accidental Needle-Sticks Because They Allow Immediate Removal And Containment Of The Needles, Especially If The Device Is Near The Area Of Use Provision Of On/Off Switch With Pilot Lamp Shock Proof-Main Circuit Breaker Is Provided. Portable, Compact, Handy , Pendent Lam Holder Usage/Application Laboratory Material Pvc Capacity 10L Packaging Type Box Weight Light Weight. Size 385*160*295 Mm Diameter 160 Mm , Pendent Lam Holder Material Plastic Style Classic Switch Installation Type Ceiling Colour White Brand Confident Shade Material Wood, Polycarbonate , Basics Storage Rack 7 Shelf 118X12x36 Inch 90 Kg Udl Breadth : 12 Inch Height : 118 Inch No. Of Shelves : 7 Shelf Type Of Product : Storage Rack , Basics Storage Rack 6 Shelf 118X12x36 Inch 90 Kg Udl Breadth : 12 Inch Height : 118 Inch No. Of Shelves : 6 Shelf Type Of Product : Storage Rack , Basics Storage Rack 5Shelf 118X12x36 Inch 90 Kg Udl Breadth : 12 Inch Height : 118 Inch No. Of Shelves : 5 Shelf Type Of Product : Storage Rack , Basics Storage Rack 4 Shelf 118X12x36 Inch 90 Kg Udl Breadth : 12 Inch Height : 118 Inch No. Of Shelves : 4 Shelf Type Of Product : Storage Rack , Rechargeable Ultra Led Torch 0.5 Watt Type : Led Torch • Material : Plastic • Color : Assorted • Rechargeable : Yes • No.Of Lumens : 60Lm • Capacity : 0.5 Watts , Mrudung / Mridangam General Shell Material Jackfruit Wood Tuning Type Lace Tuned Color Brown , Product Dimensions ?50 X 30 X 30 Cm; 6 Kilograms Batteries Included ?No Batteries Required ?No Material ?Iron And Leather Item Weight ?6 Kg , Wooden Standard Harmonium Harmonium Material Specification Reed Material Copper Material Wooden Material Of Knobs Nickled Metal Material Of Frame On The Back Keys Glass Wood Type Kail Dimension Details Length 60 Centimeter Height 20 Centimeter Width 30 Centimeter Weight 6 Kilogram General Features Types Standard Harmonium Scale Changer No Coupler Type Na Reed Set Type Na Special Reeds No Extra Notes Na No. Of Drones Na Bellow Type Seven Fold Bellow Top Body Cover No Frequency (Hz) A440 Portable Yes Keyboard With Lock No Special Keys No Number Of Keys 33 Color Brown No Of Stop Knobs 7 , Handmade Jhanjh Percussion Indian Musical Instrument Cymbal Pair (Gold) 5D , Piano Portable Keyboard 61 Keys Product Dimensions ?93 X 25.6 X 7.3 Cm; 93 Grams Batteries ?6 Aa Batteries Required. , Type Of Product: Solar Combooperating Voltage: 12Vsolar Wattage: 50W Spvbattery Include: Artheon Batteryled: Dc Ledbattery: 40Ah , Type Of Solar Module Polycrystalline Module Efficiency =15% Module Product Warranty 1 Year Charger Technology Mppt Warranty Of Pcu 12Month Output Phase Single Rated Power (Kva) 1.5 Efficiency At Stp For Linear Loading =90% Input Phase Single Nominal Battery Dc System Voltage 48 Volt Capacity Of Power Plant (Kva) 1 Battery Warranty 1 Year No Of Battery 1 Battery Capacity (Ah) 150 , Laptop Office Bag Multicolour Leather P.U. Office Bag No. Of Compartments:5 Product Dimension (Lxwxh) Cm:40X20x30 , Mobile 4 G Supported : 48Mp (F2.0) Quad Rear Camera + 8Mp (F2.2) Ultra Wide Camera + 5Mp (F2.4) Depth Camera +5Mp (F2.4) Macro Camera | 20Mp Front Camera 16.21 Centimeters (6.4-Inch) Super Amoled - Infinity U Cut Display, Fhd+ Multi-Touch Capacitive Touchscreen With 1080 X 2400 Ixels Hd+ Resolution, 412 Ppi | 16M Color Support Memory, Storage & Sim: 6Gb Ram | 128Gb Internal Memory Expandable Up To 512Gb | Dual Sim (Nano+Nano) Dual-Standby (4G+4G) Android V10.0 Operating System With 2Ghz+1.7Ghz Mediatek | Mt6768 Octa Core Processor 5000Mah Lithium-Ion Battery 1 Year Manufacturer Warranty For Device And 6 Months Manufacturer Warranty For In-Box Accessories Including Batteries From The Date Of Purchase Box Also Includes: Travel Adapter, Usb Cable And User Manual , Steel Folding Cot Steel/Iron Frame Width Of Frame +/- 5(Mm) 762 Mm Length Of Frame +/- 5(Mm) 1980 Mm Size Of Mdf Board 2100X900x17 Mm Size Of Plywood 2100X900x19 Mm , All In One Printer (Inkjet Technology Monochrome) With Adf , Stapler Big Size Half Strip All Metal Construction With Plastic Cover Quick Loading Machanism Rotating Anvil And Reload Indicator. Ideal For Frequant Stapling , Stapler Pin Big Heavy Duty Staple Pin Size 24/6 Big Staple Pin And Big Stapler Pin Use For School, Offices , Stapler Medium Size Half Strip All Metal Loading Capacity: 50/100 Pins Model: 999 Staple Used: No 10 Stapling Capacity: 20 Pages All Metal Half Strip Stapler Quality Steel Component Quick Loading , Paper Punching Machine Punching Capacity: 11 Sheets Punching Dia: 5.50 Mm Punching Distance: 80 Mm , Paper Punching Machine Medium Size Punching Capacity: 22 Sheets Punching Diameter - 5.5 Millimeters, Punching Distance - 80 Millimeters Medium Size Punch Silky Touch , Hole Diameter 5.5Mm Hole Distance 80Mm Material Metal No. Of Holes 2 Punching Capacity 36 Pages , Ice Pick(Tocha) Handle Wooden / Fibre /Plastic/Steel/ Iron Handle Size Size 4.5 , Tent House Jumbo Big Sizeextremely Light Weight Water Proof Kids Play House Tent For 10 Year Old Girls And Boys Product Dimensions Product Width 73 Cm Product Height 108 Cm Product Weight 0.4 Kg , Product Width 73 Cm Product Height 108 Cm Product Weight 0.4 Kg , Doll House Playhouse Playset Age - 3 Years+ Material - Plastic Dimensions - L 16 X B 8 X H 31 Cm , Thermos Stoneware Tea Kettle Set 1000 Ml Material Material Of Kettle Stoneware Grade Of Glass Embossed Material Of Infuser Stainless Steel Food Grade Infuser With Material Of Handle Stoneware Design Type Of Handle Fixed Artistic Design, Pattern And Logo Over Kettle Yes Artistic Design,Dimension Of Kettle Capacity Of Kettle (Mm) 1000 Wall Thckness Of Kettle (Mm) 2 Additional Items Cup And Saucer Set With Details Of Cup And Saucers Set No Of Cups And Saucers In Each Set (Nos) 2 Capacity Of Cup (Ml) 70 Wall Thickness Of Saucer 3 Overall Diameter Of Saucer (Mm) 60 Colour Of Cup And Saucer Set Na Wall Thickness Of Cup (Mm) 4 Wall Thickness Of Saucer (Mm) 60 Performance Of Kettle Suitable For Heating On Direct Flame Yes Suitable For Heating On Induction Heater Yes Suitable For Heating On Hot Plate Yes Recommended Max. Temperature For Safe Use (Degree C) 90-120 , Stainless Steel Serving Tray (Large Size) For Serving Water And Dishes Product Dimensions ? : ? 43 X 30 X 3 Cm; 330 Grams , Serving Tray Set Of 3 For Coffee/Tea/Breakfast(Printed Design) Product Dimensions ? : ? 43 X 30 X 3 Cm; 330 Grams , Tea Set Items Cup ,Soucer ,Tea Set Number Of Cup In One Tea Set 6 Pcs Number Of Soucer In One Tea Set 6 Pcs Number Of Tea Pot In One Tea Set Na Number Of Milk Pot In One Tea Set Na Number Of Sugar Pot In One Tea Set Na Material Of Tea Set Ceramic/Glass/And Other Nominal Capacity Of Tea Pot ( In Litre ) Na Nominal Capacity Of Milk Pot ( In Litre ) Na Nominal Capacity Of Sugar Pot ( In Gram ) Na Nominal Capacity Of Cup ( In Ml ) 150 Diameter Of Soucer ( In Mm ) 100 Diameter Of Cup Rim ( In Mm ) 50 Height Of Cup ( In Mm ) 50 Required Overall Length Of Tray ( In Mm ) Na Required Overall Width Of Tray ( In Mm ) Na Required Overall Diameter Of Tray ( In Mm ) Na Coller Hole Of Tray Na , Table Topglass Water Glass Lass Tableware Items Water Glass Conformity To Specification Is 1961 Product Is Bis Marked Yes Design On Glass Tableware Na Nominal Capacity Of Glass Tableware For Liquid (Ml) 300 Nominal Capacity Of Glass Tableware For Solid (Gm) Na Minimum Thickness At Any Point(Mm) 3.0 Top Diameter Of Glass Tableware(Mm) 90 Bottom Diameter Of Glass Tableware(Mm) 90, Height Of Glass Tableware(Mm) 100 Length Of Butter Dishes(Mm) Na Width Of Butter Dishes(Mm) Na , Beverage Cup, Stackable Cups, Break-Resistant Commercial Polycarbonate Glasses Table Topglass Water Glass Lass Tableware Items Water Glass Conformity To Product Is Design On Glass Tableware Na Nominal Capacity Of Glass Tableware For Liquid (Ml) 300 Nominal Capacity Of Glass Tableware For Solid (Gm) Na Minimum Thickness At Any Point(Mm) Na Top Diameter Of Glass Tableware(Mm) Na Bottom Diameter Of Glass Tableware(Mm) Na, Height Of Glass Tableware(Mm) 100 Length Of Butter Dishes(Mm) Na Width Of Butter Dishes(Mm) Na , Frame Type Free Standing Understructure Of Table Gable End And Modesty Panel Storage Provided Both Side Keyboard Tray Provided Foot Rest Not Provided Material Table Top Material Three Layer Prelaminated Particle Board(Wood Product) Of Grade Ii Type Ii Of Is 12823/Latest Gable End And Modesty Panel Material Three Layer Prelaminated Particles Board(Wood Product) Of Grade Ii Type Iii Of Is 12823/Latest Leg Material No Legs Misc Table Top Long Sides Edge To Be Banded With Pvc Tape Of 2Mm Thick With The Help Of Hot Melt Glue Table Top Plain Sides Edge To Be Banded With Pvc Tape Of 2Mm Thick With The Help Of Hot Melt Glue Gable End And Modesty Panel Plain Side Edge To Be Banded With Pvc Tape Of 2Mm Thick With The Help Of Hot Melt Glue Number Of Buffers Provided N.A Dimension Thickness Of Table Top ±2 Mm 38 Millimeter Thickness Of Gable End And Modesty Panel ±2Mm 38 Millimeter Length Of Table Top ±10 Mm 1500 Millimeter Depth Of Table ±10 Mm 850 Millimeter Height Of Table ±10 Mm 750 Millimeter Dimension Of Leg(Mmxmm) ±5Mm No Legs Storage Unit Number Of Storage Unit Provided Double Storage Width Of Storage Unit ±10Mm 400Mm Depth Of Storage Unit In Mm (±10Mm) 600 Height Of Smallest Storage Unit ±5Mm 50Mm Height Of Medium Storage Unit ±5Mm 175Mm Height Of Largest Storage Unit ±5Mm 280Mm Keyboard Tray Type Of Keyboard Tray N.A Material Of Keyboard Tray And Right Angle L-Type Supporting Bracket N.A Keyboard Adjustablity N.A Fixing Of Supporting Bracket N.A Length Of Telescopic Channe±L0mm N.A Average Weight Of Telescopic Channel ±50Gms N.A Keyboard Front Width±10Mm N.A Keyboard Depth±10Mm N.A Keyboard Height±10Mm N.A Finish Of Exposed Edges Of Keyboard Tray N.A Material Thickness Of Keyboard Tray ±1Mm N.A Footrest Material Of Footrest N.A Length Of Footrest ±10Mm N.A Depth Of Footrest ±10Mm N.A Height Of Footrest ±10Mm N.A Finish Of Exposed Edges N.A Material Thickness Of Footrest ±2Mm N.A , Table Top Glass Thickness 12Mm Type Of Glass Toughened, Heavey, Break Resistance, Smooth, , Diesel Mechanical Hopper Tipper With Three Wheeler Diesel Mechanical Hopper Tipper With Three Wheeler Generic Parametersdrawing Of The Complete Vehicle Indicating Overall Length, Width, Track And Height Will Be Provided On Demand Of Buyer Yes Vehicle Kerb Weight With Fabrication 704 Kilogram Gross Vehicle Weight 975 Kilogram Pay Load Capacity (Gvw-Vkw With Fabrication) 271 Kilogram Gradebility (Degree) 22 Maximum Speed Of Vehicle (Kmph) 60 Max Engine Bhp 9.4 Rated Rpm At Max Engine Hp 3600 Max Torque (N-M) 23.5 Rated Rpm At Max Torque 2200 Vehicle Emission Compliance Bs-Vi Vehicle Mileage (Kmpl) 26 Type Of Fuel Diesel Fuel Tank Capacity (Ltrs) (Kg In Case Of Lpg/Cng) 10.5 Engine Aspiration Natural Cooling System Liquid Anti-Air Pollution Measures Adopted Yes Electronic Control Unit (Ecu) Yes Battery Volt 12 Volt Type Of Exhaust Gas Re-Circulating System Other If Other, Mention The Type Na Lambda Sensor No Type Of Transmission Mechanical Type Of Clutch Multi Disc Wet Type Gearbox Manual No Of Forward/Speed Gears 5 Gear Ratio 26 Type Of Suspension System Hydraulic Telescopic Speedometer Yes Designation Of Front Wheel 4.5-10, 8 Periodical Renewal Designation Of Rear Wheels 4.5-10, 8 Periodical Renewal Type Of Wheel Rims Sheet Metal Type Of Steering Control Handle Bar Location Of Steering Centre Type Of Front Brakes Drum Type Of Rear Brakes Drum Head Lamp High Beam Yes Head Lamp Dipped Beam Yes Front Position Light Yes Tail / Stop Light Yes Number Plate Illumination Light Yes Direction Indicator Lights, Front And Rear Yes Parking Lights Yes Reversing Light(S) Yes Reflex Reflector Rear Yes Reflex Reflector Side(If Provided) Yes Hazard Warning Lamp (Wherever Applicable) Yes Rear-View Mirrors Yes Constructional Parameters Length Of Chassis 3145 Millimeterwidth Of Chassis 1490 Millimeter Wheelbase 2100 Millimeter Rear Overhang 1130 Millimeter Capacity Of Carrier (Cu-M) 1.25 To 2.5 Mention Capacity Of Carrier (Cu-M) 2 Tipping Facility Available Yes Tipping Angle 45 Degree Tipping Operation Hydraulic Lifting Pump , E Garbage Hydraulic Garbage E-Cart With Tipping Facility Type Of E Cart Fully Electric, Battery Operated Motor Driven For Carrying Bins Model Number Of E- Cart Maxi E Cart Colour Of E Cart Green And Blue The E Cart Must Fabricated From Good Quality Steel Properly Painted To Avoid Rusting For More Than 5 Years, Yes Name And Grade Of Steel From Which E Cart Body Framed Ms And Alloy Steel Kerb Weight Of E- Cart (Kg) 247 Kilogram Garbage Carrying Capacity (Kg) 310 Kilogram Run Distance (For A Full Charge Of Battery , To Be Tested With Full Load At Maximum Ais-040 )) (Km) 95 Number Of Bins 2 Capacity Of Individual Bins In Litres (Ltrs) 155 Liter Type Of Chassis For E Cart Tubular Ground Clearance As Per Is : 9435 (Mm) 180 Wheel Base (Mm) 2090 Millimeter Turning Radius (Mm) 2200 Millimeter Power Transmission From Motor Shaft To Wheels Direct Mounting Please Specify The Mechanical Mechanism Otherwise Put Na Na Tipping Facility Yes Tipping Angle 75 Degree Method Of Tipping Hydraulic If Others, Mention The Method Of Tipping Hydraulic Type Of Battery As Per Ais-048 Lead Acid , Ev Grade , Tubular Deep Dischargecapacity Of The Battery Approved By Icat/Arai (Ah) 110 Battery Voltage ,Nominal (Volts) 48V Maximum Overall Dimensions Of The Battery ( L X Wx H ) (Mm3) 410 X 176 X 210 Nominal Filled Weight Of The Battery (Kg) 120 Kilogram Motor Controller ( Must Suitable For Starting, Accelerating, Decelerating, Driving , And Stopping Of E Cart Yes Battery Charger 220/230 V Nominal Input Voltage , High Efficiency Type Charging Current (A) 12 Type Of Motor Brushless Dc Motor Motor Output Power ,48V/60V At Full Load (Watt) 1200 Overall Efficiency Of The E Cart ( To Be Tested At Full Load With Maximum Speed As Per Concerned Ais Standards (%) 85 Gradeability Of E-Cart , ( To Be Tested At Full Procedure As Per Ais -003 Load (Degree) 15 Constructional Seating Facility For Driver Only Length Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct , 2014 (Meters) 2.8 Width Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct, 2014 (Meters) 1 Height Of E -Cart As Per Gazette Notification By Ministry Of Road And Transport Oct , 2014 (Meters) 1.8 Dimensions Of The Cabin Provided For Bins (Mm X Mm X Mm) (Mm3) 1500 X 900 X 1400 Size Of Front Tyre (Mm) 90 X 90 X 12 Size Of Rear Tyre 90 X 90 X 12 Brake Type (Front) Drum Brake Type ( Rear ) Drum Suspension System (Front) Shockers Suspension System ( Rear ) Leaf Spring Reverse Gear Facility Yes The Mounting Of Batteries Yes Vehicle Lighting System Filament Type Instrument Panel Containing Speedometer And Battery Charging Indicator Yes Glass Windshield With Wiper Motor As Approved By Icat/Arai Yes Battery Make As Per Ais :048:2009 Exide If Others Please Specify The Name Of Brand ,Otherwise Put Na (As Per Ais048 2009) Na Equipped With Start And Stop Button, Parking Lights , Back Lights With Reverse Gear Facility Yes Equipped With Fire Extinguisher Yes Equipped With First Aid Box Yes Yellow Color Reflective Tape On Front And Rear Side Of The E Cart Yes E Cart Integration , Yes Performance Parameters Speed Of The E- Rickshaw As Per Cmvr -2014 With Latest Amndmt (To Be Tested With Full Load ) (Kmph) 23 Battery Warranty 1 Year No. Of Free Service 1 Year Compliance Of Centre Of Gravity Of E Cart As A Compulsory Norms For Safety Yes Confirming To Applicable Environmental Test Yes Noise Level Must Be Low During Operation Yes , Diesel Bs-Vi Hopper Tipper Dumper With Capcity 2.5 Cubic Metres With Four Wheeler Generic Parameters Type Of Tipper Garbage Tipper Type Of Tipper If Other Tipper ,Please Declare Type Of Tipper, Garbage Tipper Make Of Chassis 4 Wheelr Chasis Type Of Chassis Frame Conventional Category Of Vehicle For Which Chassis To Be Used Light Capacity Commercial Vehicles Type Of Chasssis Chassis With Facecowl Type Of Fuel Diesel Vehicle Emission Complaince Bs-Vi Fuel Consumption ( Declared By Oem As Certified By Test Agency Under Rule 115Of Cmvr 1989) (Kmpl) 22Speed, Max (Km/Hr) 60Max Engine Power Bhp (Bhp@Rpm) 20Rated Rpm At Max Engine Power 3600 Max Engine Torque (N-M@Rpm) 45 Rated Rpm At Max Engine Torque 3600 Main Engine Aspiration Natural Aspiration No. Of Cylinder In Main Engine (Nos) 2 Fuel Tank Capacity (Ltrs) 30 Liter Gradeability Of Vehicle With Load( %) 13.2 Ground Clearance (Mm) 160 Millimeter Wheel Base (Mm) 2100 Millimeter Kerb Weight (Kg) 920 Kilogram Gross Vehicle Weight (Kg) 1675 Kilogram Type Of Bis Marked Vehicle Tyre Radial Chassis Transmission System Manual Number Of Speed/ Forward Gears 5 Type Of Steering Manual Turning Radius,Min (Mm) 4300 Millimeter Speed Governers/Ecu Yes Abs Fitted No Front Vehicle Brake Disc Brake Hydraulic Rear Vehicle Brake Drum Brake Hydraulic Type Of Clutch Single Plate Dry Tipping Angle (Degree) 48 Tipper Container Capacity/Volume(Cubic Metres) 2.5 Consructional Parameters Size Of Front Tyres (Mm) 145 R12 Size Of Rear Tyres (Mm) 145 R12 Size Of Wheel (Mm) 304.8 Millimeter Tipper Body Pivot Length (Mm) 1546 Millimeter Tipper Body Length (Mm) 2000 Millimeter Tipper Body Height (Mm) 670 Millimeter Overall Height Of Tipper From Ground (Mm) 1489 Millimeter Body Plate Thickness (Mm) 2 Main Frame Thickness (Mm) 3 Millimeter Hydraulic System Yes Tipping Hydraulic Cylinders(Make) Liftwell/Dantal/Eqv Hydraulic System Driven By Main Engine Tipper Container Material Mild Steel Thickness Of Sheet From Tipper Collector Container Made (Mm) 2 Millimeter Dumping Height (Mm) 550 Millimeter Engine Oil Pressure Level Indicator In Control Panel Yes Fuel Gauge Indicator In Control Panel Yes Engine Cooling Liquid Temperature Indicator In Control Panel Yes Operating Hour Meter No Locking/Unlocking Of Tipper Discharge Container Yes Lowering/Lifting Of Tipper Discharge Container Yes Counter Weight No If Yes Counter Weight (Kg) 0 Kilogram Paint Automotive Paint Performance Parameters Standard Sparewheel And Tool Kit Yes Warranty Time (Month) 12 Month No. Of Free Service (Nos) 3 Battery Warranty (Months) 12 Month Warranty Distance (Km)(Unlimited During Warranty Period) Yes , Vehicle Mountable Fogging Machine Operated Electrical Single Blor Type And Starting Of Machine Type Vehicle Mountable Starting Electrical Material Chemical Tank Material Stainless Steel Fuel Tank Material Crc Steel (Portable) Chemical Tank Material)/Thickness Stainless Steel/0.95Mm Grade X04cr19ni9 Fuel Tank (Material)/Thickness Crc Steel/1.0Mm Grade Cr4 Engine Output Engine Output (Minimum)/Chemical Discharge Capacity (Max.) (Kw/Lph) 75/160 (Vehicle Mountable) Engine Output (Minimum)/Chemical Tank Capacity (Min.) (Kw/Litres) 75/160 Engine Output (Minimum)/ Fuel Tank Capacity (Min.) (Kw/Litres) 75/20 Other Physical Characteristics Duration To Operate Without Refuel (Hrs) 1.5 Noise Level (Decibel) 109 Durability After 50 Hrs Auto Cut Off For Elimination Of Fire Accident, Non Pressurized Fuel Tank To Control Temperature Strap Test As Per Cl.8.4 Yes Standard Tools, Spares And Accessories Yes Rechargeable Battery Unit Capacity (Volts) 12 Annual Maintenance Contract For Fogging Machine (Years) 1 , Vehicle Mountable Fogging Machine Operated Electrical Single Blor Machine Type Vehicle Mountable Starting Electrical Material Chemical Tank Material Stainless Steel Fuel Tank Material Stainless Steel Chemical Tank (Material)/Thickness Stainless Steel/0.95Mm Grade X04cr19ni9 Fuel Tank (Material)/Thickness Stainless Steel/0.95Mm Grade X04cr19ni9 Engine Output Engine Output (Minimum)/Chemical Discharge Capacity (Max.) (Kw/Lph) 37/75 (Vehicle Mountable) Engine Output (Minimum)/Chemical Tank Capacity (Min.) (Kw/Litres) 37/75 Engine Output (Minimum)/ Fuel Tank Capacity (Min.) (Kw/Litres) 37/10 Other Physical Haracteristics Duration To Operate Without Refuel (Hrs) 2 Noise Level (Decibel) 102 Durability After 50 Hrs Auto Cut Off For Elimination Of Fire Accident, Non Pressurized Fuel Tank To Control Temperature Strap Test As Per Cl.8.4 Yes Standard Tools, Spares And Accessories Yes Rechargeable Battery Unit Capacity (Volts) 12 Annual Maintenance Contract For Fogging Machine (Years) 1 , Chemical Dosing System Consists Of 150 Ltr Tank Mounted On Ms Frame With Pump System With Upvc Piping. Imd-50 Flow Rate 0-50 Ltr Per Hour (1 Working Machine Only ) With Agitator Mixer Mounted On Tank Specification : 0.5Hp 3 Phase Motor With 0.5Hp Worm Gear Assemble Suitable Shaft. (System Make : Iflow) , Chemical Dosing System Consists Of 150 Ltr Tank Mounted On Ms Frame With Pump System With Upvc Piping. Imd-50 Flow Rate 0-50 Ltr Per Hour (1 Working + 1 Standby) With Agitator Mixer Mounted On Tank Specification : 0.5Hp 3 Phase Motor With 0.5Hp Worm Gear Assemble Suitable Shaft. (System Make : Iflow) , Cycle Rickshaw Garbage Container Closed Type, Box Size 12 Cft Capacity. Heavy Duty 5 Bar Frame, And Chassis Of 35X35x3.5Mm. Angle Iron With Box Fitted, Box Made Of 1.25 Mm Sheet And Manual Tilting Arrangement, Complete Painted. , Frp Indoor Merry Go Round Dimensions 44 × 44 × 44 Cm , Outdoor Merry Go Round Dimension Product Area 1500 Mm Dia Safe Play Area 2500 Mm Dia , Slide Ladder (Preschool Kit) Virgin Polyethylene And Full Arch Shape Material Slide Ladder Made Up Of Virgin Grade Polyethylene Plastic Virgin Polyethylene Bolts Quality (To Provide Greater Stability To Slide) To Provide As Per Approved Advance Sample Dimension And Mass Overall Length Of The Product (When Assembled) 2415Mm Overall Width Of The Product (When Assembled) 965Mm (Stare Supporting Base) And 432 Mm (Sliding Part) Length Of Sliding Part 1829 Mm Length Of The Stair Panel 1270 Mm Step Rise Of Each Stair 445 Mm Long Minimum Overall Plastic Weight Of Product 16 Kg , Adjustable Basketball Kids Multicolor Assembly Required ?Yes Batteries Required ?No Batteries Included ?No Material Type(S) ?Plastic Remote Control Included? ?No Color ?Red; Blue Product Dimensions ?35 X 45 X 25 Cm; 7.87 Kilograms , Jeevan Drop 100 Ml Sodium Hypochlorite Solution , Tablet-Processor Qualcomm® Snapdragon™ 429 Processor (4 Cores, 4X A53 @2.0 Ghz) Operating System Android 9 Display Type 25.65Cms (10.1) Hd (1280X800) Ips 300Nits Memory 3 Gb Soldered Lpddr3 Hard Drive 32 Gb Emmc Warranty 1 Year On Tablet, 6 Months On Accessories (Carry-In) Ac Adapter 10W Voice Service Voicecall Graphics Integrated Qualcomm® Adreno 504 Graphics Battery Integrated 4850Mah Camera Front 2.0Mp + Rear 5.0Mp Wireless 4G Calling + Wifi Volte & Bluetooth® 4.2 , Ro 15 Ltr Performance Parameters Maximum Input Water Tds Allowed To The System 2000 Type Of Water Purification Technology Ro Aavailability Of Sediment And Activated Carbon Filter Yes Operation Fully Automatic With Auto Cut Off Conformity To Standard For Ultraviolet System Is 14724 (Latest) For Water Purification System Recovery At 27 Degree Centigrade 30-40 Output Water Forming Standard Is 10500 (Latest) Filtration Capacity In Liter/ Hour 15 Provision Of Arsenic Removal Yes Provision Of Floride Removal Yes Provision Of Chloride Removal Yes Alkaline Filter No Storage Tank Inbuilt Type Of Out Put Water Storage Tank Abs Food Grade Storage Tank Capacity (Storage Tank External For Higher Capacity If Required To Be Arranged By Buyer) 8Ltr Minimum Inlet Pressure 0.6 Kg/Cm2 Maximum Inlet Pressure 3.5 Kg/Cm2 Maximum Inlet Temperature 40 Degree Digital Display No Real Time Tds Display No Real Time Ph Display No High Pressure Pump Yes Raw Water/Chemical Raw Water/Chemical Cleaning Pump Yes Micron Filter Yes Total Dissolved Solids Removal Percentage From Ro Membrane 90% Particulate Filter Porosity 20 Micron Pressure Vessel Sand Filter No Pressure Vessel Carbon Filter Yes Pressure Vessel Dual Media Filter No Membrane Housing Yes Body Of Filter Abs Food Grade Auto Cut Yes Number Of Candles 5 Power Supply 230 Volt Single Phase Installation Type Wall Mounted , Mothe Patele 5 Kg Capacity , Mothe Patele Zakan , Sarata Motha , Chamcha Motha , Plate For Break Fast Ss Food Grade , Mothi Parat , Chhoti Parat , Glass , Water Jar , Handa 10 Ltr , Water Tank 50 Ltr Steel , Fruit Set For Kids , Vegitable Set For Kids , Office Table 4X2 , Office Fibre Chair , Abcd Chart Set Of 5 (Abcd, Number, Animal, Flower, Vehicle) , Hand Wash Station 3 Stand Material Ss Grade Ss304,Ss316,Etc. Length 4-5 Feet Width 2-3 Feet Ss Sink 3 Nos Foot Operated Number Of Tap 3 , Sanitary Pad General Napkin / Pad Consists Of Outer Covering With Sufficient Number Of Channels For Leak Protection Yes Type Of Napkin Large With Tab Napkin / Pad Shall Have A Non-Absorbent Barrier On One Side Which Shall Have An Identifying Thread Or Marking Indicating Clearly The Side Of The Barrier Yes Adhesive Back Strip Yes Color Of Pad White Soft,Comfortable,Breathable,Odorless , Anti-Bacterial , Non-Allergic And Bio-Compatible,Bio-Degradable Yes Ph Of The Absorbent Material Of The Napkin As Per Is : 1390-1961 Yes Absorbency With Prescribed Fluid @50 Ml/Min Instead Of 30 Ml Of Cl 5 (1) Of Is : 5405/1980 (First Revision) Reaffirmed 2012, With Amendment 1, Without Leakage On Bottom And Sides Yes Disposability - Disposable Napkin /Pad With Covering Removed Shall Dis Integrate In The Water In Not More Than 5 Minutes When Immersed In 15 Litres Of Water And Stirred Yes Instructions Indicating Removal Of Non-Absorbent Barrier Before Flushing Of Napkin Yes Standard Conformity To Indian Standard Is: 5405-1980(Latest) Except For Absorbency And Size Yes Product Is Bis Marked No Cm/L No(If Product Is Isi Marked) 0 Dimensions Size Of Napkin (Length X Width X Thickness) (In Mm) (240+-10)X (75+-5) X (10 +-1.5) Weight Of Single Pad (In Grams) 10+-1 The Thickness Of The Pad Shall Be Average Of The Height Measured By Stacking 10 Complete Pads Yes Napkin / Pad Should Have Uniform Thickness Throughout Without Any Wrinkle Or Distortion Yes Material Material Of Outer Cover/Layer Rayon Absorbent Filler Material Cellulose Pulp Absorbent Filler Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material Yes The Covering Of The Absorbent Filler Shall Be Of A Good Quality Poly-Perforated Film Sleeve, Gauze Or Non-Woven Fabric With Sufficient Porosity To Permit The Assembled Pad To Meet The Bsorbency Requirement Yes If Cotton Gauze Is Used For Covering Of The Absorbent Filler, It Shall Conform To Is 758-1975 Na , Automatic Sanitiser Dispenser Machine With Battry Branded 5 Ltr (Blue Mount/Dolphy/Euronics) , Alcohol Based Hand Sanitizer/Hand Cleanser 5 Ltr Can Hand Rub Contains Glycerol-1.45%,Hydrogen Peroxide I.P.- 0.125% V/V,Ethanol 60-95% W/W Conformity To Standard Ip , Composition Ethanol Form Of Supply Liquid Shelf Life (In Months) From The Date Of Manufacturing 36 Efficacy Of Killing ~ 100% Germs After Contact Yes Hand Rub Shall Be Clear And Colorless Yes Hand Rub Shall Not Have Any Unpleasant Odour Or Smell Yesspecial Precaution For Storage Room Temperature Special Warnings And Precautions For Use Stay Away From Eyes , Sodium Hypochlorite 50 Kg Can Sodium Hypochlorite Solution (Grade 1) Conforming To Indian Standard Is 11673(Latest) Yes Whether Isi Marked No Cm/L Number(Must Declare,If Isi Marked) Na Food And Drug License Available No Test Report Details Availability Of Test Report From Central Govt/Nabl/Ilac Accredited Lab To Prove Conformity To Specification Yes Test Report To Be Submitted To The Buyer On Demand Yes Food And Drug License Number(Write Na ,If Not Available) Ad/006 Physical Characteristics Form Liquid Colour Pale Yellowish Green Requirements For Sodium Hypochlorite Solution Relative Density(At 25?/25?C) 1.18 Available Chlorine Percent By Mass By Volume 10 Total Chlorine Percent By Volume(As Cl) 10 Free Alkali (As Naoh) (Min)G/L 1 Free Sodium Arbonatena2co3 (Max)G/L 0.5 Iron(As Fe)(Max) Ppm 0.4 Sodium Chlorate 0.05 , Shoes Stand , Dustbeen 10 Ltr , Rocker For Kids - Multi-Color Plastic Horse Ride-On Toy For Kids 0 To 5 Year Material:- This Rocker For Kids Is Made Up Of Non-Toxic Harmless Plastic. , Longevity: These Playgro Rockers For Kids Are A Standout Toy For Both Its Quality And Its Longevity And Is 100% Manufactured In India. High Precision: The Parts Of This Kids Rocker And Ride Are Made Using High Precision Machines. , Kids Toy Tricycle With Heavy Iron Pipe & Plastic Product Type Tricycles For Kids Age 6-12 Months;12-24 Months;2-4 Years Ideal For Infants Color N/A Material Plastic;Iron Power Required Yes Product Dimension 55 Cm X 38 Cm X 59 Cm , Tower Block Game Set For Children To Learn Shapes, Colours And Sizes Keeps Kids Engaged By Building Various Structures Safe For Toddlers To Use; Tested In An Nabl Accredited Lab Against 72 Different Safety And Performance Parameters Is9873 Certified Product Meets Quality And Safety Standards Ideal For Homeschooling, Playgroups And Kindergarten Made In India , Shoes Stand Plastic Made , Play Ball (Set Of 10 Ball ) With Different Colours Suitable For Kids Age 0 To 6 Years , Diesel Mechanical Hopper Tipper With Three Wheeler Certification Arai/Vrde/Icat Chassis Certification Arai/Vrde/Icat No Aaon 0406 F01 Form 22 A - For Compliance With Pollution Standards, Safety Standards Of Components And Road Worthiness As Per Cmvr Rules Yes Registration To Local Rto (Regional Transport Office)/Rta(Regional Transport Authority) By Seller Yes Generic Parameters Drawing Of The Complete Vehicle Indicating Overall Length, Width, Track And Height Will Be Provided On Demand Of Buyer Yes Vehicle Kerb Weight With Fabrication 700 Kilogram Gross Vehicle Weight 974 Kilogram Pay Load Capacity (Gvw-Vkw With Fabrication) 496 Kilogram Gradebility (Degree) 23.8 Maximum Speed Of Vehicle (Kmph) 60 Max Engine Bhp 9.4 Rated Rpm At Max Engine Hp 3600 Max Torque (N-M) 23.5 Rated Rpm At Max Torque 2200 Vehicle Emission Compliance Bs-Vi Vehicle Mileage (Kmpl) 30 Type Of Fuel Diesel Fuel Tank Capacity (Ltrs) (Kg In Case Of Lpg/Cng) 10.5 Engine Aspiration Natural Cooling System Liquid Anti-Air Pollution Measures Adopted Yes Electronic Control Unit (Ecu) Yes Battery Volt 12 Volt Type Of Exhaust Gas Re-Circulating System Cooled If Other, Mention The Type Na Lambda Sensor Yes Type Of Transmission Mechanical Type Of Clutch Multi Disc Wet Type Gearbox Manual No Of Forward/Speed Gears 5 Gear Ratio 26 Type Of Suspension System Spring With Damper Speedometer Yes Designation Of Front Wheel 4.50-10.8Pr Designation Of Rear Wheels 4.50-10.8Pr Type Of Wheel Rims Sheet Metal Type Of Steering Control Handle Bar Location Of Steering Centre Type Of Front Brakes Drum Type Of Rear Brakes Drum Head Lamp High Beam Yes Head Lamp Dipped Beam Yes Front Position Light Yes Tail / Stop Light Yes Number Plate Illumination Light Yes Direction Indicator Lights, Front And Rear Yes Parking Lights Yes Reversing Light(S) Yes Reflex Reflector Rear Yes Reflex Reflector Side(If Provided) Yes Hazard Warning Lamp (Wherever Applicable) Yes Rear-View Mirrors Yes Constructional Parameters Length Of Chassis 3145 Millimeter Width Of Chassis 1490 Millimeter Wheelbase 2100 Millimeter Rear Overhang 735 Millimeter Capacity Of Carrier (Cu-M) 1.25 To 2.5 Mention Capacity Of Carrier (Cu-M) 2 Tipping Facility Available Yes Tipping Angle 45 Degree Tipping Operation Hydraulic Lifting Pump , Fogging Machine Single Blor Type And Starting Of Machine Type Portable Pulse Jet Type Starting Manual Material Chemical Tank Material Hdpe Fuel Tank Material Hdpe (Portable) Chemical Tank (Material)/Thickness Hdpe Density:0.935G/Cc,Polymer Content 99.45% Fuel Tank (Material)/Thickness Hdpe Density:0.935G/Cc,Polymer Content 99.45% Engine Output Engine Output (Minimum)/Chemical Discharge Capacity (Max.) (Kw/Lph) 10/20 (Portable) Engine Output (Minimum)/Chemical Tank Capacity (Min.) (Kw/Litres) (10/17.5)/5 Engine Output (Minimum)/ Fuel Tank Capacity (Min.) (Kw/Litres) 10/1.2 Other Physical Characteristics Duration To Operate Without Refuel (Hrs) 1 Noise Level (Decibel) 102 Durability After 50 Hrs 50 Strap Test As Per Cl.8.4 Yes Standard Tools, Spares And Accessories Yes Rechargeable Battery Unit Capacity (Volts) 12 Annual Maintenance Contract For Fogging Machine (Years) 1 , Sanitary Pad Vending Machine General Type Of Machine Automatic Type Of Fitting Wall Mountable Color Others Napkin Size For Loading Extra-Large Napkin Fold Trifold Operating Features Coin Operated Multiple Coins Accepted Yes Number Of Napkins/Pads Provided/Loaded With The Vending Machine 35 Multiselection Of Napkin Type Yes Number Of Selection Options 1 Vending Option Vertical Accessibility For Free Vending Utility Service Token Type Of Loading Spiral Vending Napkin Individually Packed Yes Led Illumination Provided For Visibility Of Napkins In The Machine No Visibility Window Yes Pre-Programmable Facility Available Yes Maximum Storage Capacity (Nos)(Nos) 25-50 Digital Counter For Accounting Yes No Stock Message Display Available Yes Built-In Program For Automatic Coin Return/Reject System When There Is No Stock Or No Power No Built-In Program For Automatic Currency Block/Reject System When There Is No Stock Or No Power No Built-In Price Programming Software For Changing The Price Yes Sales Data Retrieval Yes Any Additional Built-In Features Available Easy Access To Use Functional Features Material Of The Outer Body Mild Steel(Ms) Type Of Battery Na Built-In Charger No All Ms Parts Are Duly Painted By Powder Coating Mode Of Function Stand Alone Operating Power Source Electronic Input Power Supply 220V +/- 10%, 50Hz, Single Phase Ac Battery Backup Available No Battery Backup Time (Hrs) Na Power Consumption(Watt) Na Dimensions Width (Mm) 100-200 Depth (Mm) 200-400 Height (Mm) 800-1000 Weight (Kg) 10-20 Thickness Of Ss/Ms Sheet (Mm) 1.2 Thickness Of Frp/Plastic Sheet (Mm) 1-2 , Sanitary Pad Disposal / Incinerator Machine General Type Floor Mountable Purpose Burn Used Sanitary Napkins To Sterile Ash And Stop Automatically Color Operation Mode Electronically Operated, Fully Automatic Loading Type Top Loading Stand Provided Yes Number Of Chambers Two Trap Door Available Yes All Ms Parts Powder Coated Yes Spare Parts Should Be Available For Minimum 5 Years From Date Of Supply Yes All Electrical Parts Are Isi Marked Yes Dimensions Of Main Unit Thickness Of Thermal Insulation Material (Mm) 40 Millimeter Thickness Of Ms/Ss Sheet Of Housing Cabinet (External) (Mm) 1.2 Millimeter Thickness Of Ms/Ss Sheet Of Burning Chamber (Internal) (Mm) (Min) 3 Millimeter Machine Width(Mm) 401-500 Machine Depth (Mm) 501-700 Machine Hight(Mm) 901-1200 Machine Weight(Kg) 51-250 Door Width(Mm) 500-100 Door Height(Mm) 151-200 Thickness Of Door Including Insulation (Mm) 25 Millimeter Internal/Burning Chamber Shape Vertical Cylindrical Flexible Emission Outlet Pipe Dia (Mm) 76 Millimeter Detachable Ash Tray Length (Mm) 301-400 Detachable Ash Tray Width (Mm) 151-200 Detachable Ash Tray Height (Mm) 31-50 Stand Height (Mm) 500 Millimeter Stand Width (Mm) 200-300 Stand Depth (Mm) 100-200 Material Of Machine Unit Material Of Housing Cabinet (External) Mild Steel(Crca) Sheet Material Of Burning Chamber (Internal) Stainless Steel Sheet Of Ss-304 Grade Finish Of Ms Parts Of Cabinet Na Material Of Thermal Insulation High Density Ceramic Fiber Sheet Constructional Features Thermal Insulation Of Burning Chamber Housed In Outer Chamber Yes Burning Chamber Tray Provided Yes Emission Outlet Pipe Location Top Of Machine Means Of Connecting The Unit Outlet With Flue Gas Emission Pipe Flanged Type Of Door Lock Provided Latch Lock Control & Functional Features Temperature Indicator Provided Yes Timer Provided Yes Auto Cut-Off Temperature Display Yes Digital Display To See Actual And Set Temperature Yes Minimum Burning Temperature (Degree C) 800 Burning Capacity Per Day (Number Of Napkins) 700-1000 Burning Capacity At A Time (Number Of Napkins) 26-50 Residue Ash Per Napkin (Gms) 2 Gram Burning Time Of Full Capacity Napkins/Pads (Minutes) (Max) 30 Minute Skin Temperature Of The Unit Under Operation (Deg C) 16-20 Installation, Training, Demonstration And Plumbing Included Yes Electrical And Safety Features Automatic Digital Controller For Time Yes Automatic Digital Controller For Temperature Yes Equipment On/Off Indicator Provided Yes Power Supply 230V +/-10%, 50Hz, Single Phase, Ac Supply Electrical Power Consumption(Watt) 500-1000 Minimum Length Of Power Chord To Be Supplied Along With Machine (Mtr) 2 Meter Type Of Heater Ceramic Heater Containing Coil Power Saver (Auto Power Cut-Off) Yes Safety Mcb Provided (16A To 30A) Yes Protection Against Electric Shock When Checked As Per Is:302-1/2008 Yes Minimum Insulation Resistance (Ir) At 500 Vdc (Mega Ohm) 2 Maximum Electrical Insulation And Leakage Current As Per Is:302-1/2008, (Ma) 0.21 Maximum Earthing Continuity Test When Tested As Per Is:302-1/2008 (Ohm) 0.1 Hv Test At 1000 V Rms For 1 Sec When Tested As Per Is:302-1/2008 No Breakdown Shall Occur During The Test Smoke Control Unit (Scu) Type Of Scu (Smoke Control Unit) Top Mounted Material Of Housing Of Smoke Control Unit (Scu) Mild Steel(Crca) Cabinet Finish Of Ms Parts Of Scu Cabinet Epoxy Anti Rust Proof Painting For Superior Finish Overall Height Of Scu (Mm) 300 Overall Width Of Scu (Mm) 100-300 Overall Depth Of Scu (Mm) 100-300 Number Of Chambers For Filteration Of Smoke Emission Two Both Carbon Control And Foul Odour Control Chambers For Filteration Of Smoke Emission Yes Number Of Filters In Carbon Control Chamber One Type Of Filters In Carbon Control Chamber Ceramic Blanket As A Filter Number Of Filters In Odour Control Chamber One Type Of Filters In Odour Control Chamber Activated Carbon Filter Blower Type Centrifugal, Direct Driven Blower Rpm 1800 Power Supply Of Scu 230V +/-10%, 50Hz, Single Phase, Ac Supply Minimum Length Of Flexible Emission Outlet Pipe To Be Supplied Along With Machine (Mtr) 3 Cost Of Additional Flexible Emission Outlet Pipe, If Required On Actuals To Be Paid By The User Yes Emission Standard For Smoke Conformity To Cpcb, Min Of Environment & Forests Standard, Solid Waste Management Rules (Swm), 2016 Yes Particulates (Half Hourly Average) (Mg/Nm3) (Max) 50 Hcl (Half Hourly Average) (Mg/Nm3) (Max) 50 So2 (Half Hourly Average) (Mg/Nm3) (Max) 200 Construction Of (Half Hourly Average) (Mg/Nm3) (Max) 100 Construction Of (Daily Average) (Mg/Nm3) (Max) 50 Total Organic Carbon (Half Hourly Average) (Mg/Nm3) (Max) 20 Hf (Half Hourly Average) (Mg/Nm3) (Max) 4 Nox (No And No2 Expressed As No2) (Half Hourly Average) (Mg/Nm3) (Max) 400 Total Dioxins And Furans ( 6 To 8 Hours Sampling Basis, Please Refer Guidelines For 17 Concerned Congeners For Toxic Equivalence Values To Arrive At Total Toxic Equivalence) (Ng Teq/Nm3) (Max) 0.1 Cd + Th + Their Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.05 Hg And Its Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.05 Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+Their Compounds (Sampling Time Anywhere Between 30 Minutes And 8 Hours) (Mg/Nm3) (Max) 0.5 Loss On Ignition (Max) (% Dry Weight Of The Material) 5 , Water Cooler 60 Ltr/80 Ltr/100 Ltrtype Storage Cooling Capacity Litres/Hour 60/80/100 Liters/Hour Storage Capacity 80 /60/100 Liter Maximum Energy Consumption (Watt) 775 Watt For 60 Ltr/Hr Cooling Cap. Power Factor 0.85 Eco-Friendly (Non Cfc Refrigerant) Es Water Tank Sheet Material And Thickness Stainless Steel (Grade Aisi 304) With Puf Insulation, Thickness =0.6 Mm Water Tank Cover And Lid Bottom Sheet Material High Impact Polystrene(Hip) Water Tank Cover And Lid Bottom Sheet Thickness 1.5 Millimeter Cooler Cabinet Sheet Material Stainless Steel (Grade Aisi 304) Cooler Cabinet Sheet Thickness 0.8 Millimeter Warranty On Machine 1 Year , Ss Skid- The Basic Assembly Of Ro Is Mounted On The Skid The Quality Of The Skid Is Made Of Stainless Steel 304 -For Suitable For 1000 Ltr Ro , Raw Water Tank The Filtered Product Water Is Stored In This Tank. This Tank, Too Is Maded Pvc 4 Layer Food Grade Tank Capicity : 3000 Ltr-For Suitable For 1000 Ltr Ro , Treated Water Tank . The Filtered Product Water Is Stored In This Tank. This Tank, Too Is Maded Stainless Steel Water Tank Steel Grade 304 Food Grade Tank Capicity : 1000 Ltr. -For Suitable For 1000 Ltr Ro , Raw Water Pump The Rwp Sucks Water From The Raw Water Tank & Forwards It To The Ro System. Having Capacity Of 3000 Lit Per Hr. Of Self Priming Centrifugal Pump Its Make Of Cri/Groundfos .5 To 1Hp Power Consumption And Pressure 3-4 Kg Per Sq.Cm Etc Complete-For Suitable For 1000 Ltr Ro , Pressure Sand Filter Pressure Sand Filter Is Of Vertical Type Of Diameter 13 Inches And 54 Inches In Height Having Volume Of 110Liters (Pentair) Made Up Of Frp Its Operation Type Is Manual Multiport Valves Etc Complete -For Suitable For 1000 Ltr Ro , Pressure Carbon Filter Pressure Carbon Filter Is Of Vertical Type Of Diameter 13 Inches And 54 Inches In Height Having Volume Of 110Liters (Pentair) Made Up Of Frp Its Operation Type Is Manual Multiport Valves Etc Complete -For Suitable For 1000 Ltr Ro , Anti Scalnt Dosing System -Having Pump In A Set Made Of Edose It Is Electronic Diaphragm Type Its Capacity Is 0.3 Liter Per Minute. Having One Hdpe /Plastic Tank Capacity 80 Liters. -For Suitable For 1000 Ltr Ro , Cartidge Jumbo Filter Housing Cartidge Jumbo Filter Housing In Two Numbers Made Of Food Grade Pp And Diamentions Are 20X4 -For Suitable For 1000 Ltr Ro , Jumbo Micron Cartidge Filter 2 Nos - It Is Made Of Poly Propylene And Having Flow Rate Is 5000 Lit Its Diamentions Are 20 X 4 Its Rating Is 5 Micron In 2 Nos-For Suitable For 1000 Ltr Ro , High Pressure Pump -It Has The Power Of 3Hp It Is Vertical Centrifugal Multi Stage Pump Make Of Cri/Cnp/Shakti Hpp Sucks Water From The Micron Filter & Passes It To The Membrance. -For Suitable For 1000 Ltr Ro , Pressure Tube Ro Module Consisting Of Membrane Housing With Ro Membrane Mounted On Skid It Is Made Of Ecoline (Penteir)Uki/Ss Its Size Is 8X40 In A One Number -For Suitable For 1000 Ltr Ro , R.O Membrane The Membrane Contains Minute Holes Of Size 0.0001 Micron.As A Result No Bacteria Or Any Virus Can Pass Through This It Its Tfc Polymide And Size Is 40 Diameter And 40 Length Make Of Hydronautics Cpa-2 Equivalent -For Suitable For 1000 Ltr Ro , Flow Indicator Flow Indicators In Two Numbers Made Up Of Flot Type Pannel Mountedits Max Temp 40 Degree Cal.And Measured At Ro Module Product Flow And Ro Module Reject Flow-For Suitable For 1000 Ltr Ro , Pressure Gauge -Pressure Gauge Are In Two Nos And Range In Between 0 To 20 Kg / Sq Cm Its Location Are At Ro Module Inlet And Ro Module Reject Flow-For Suitable For 1000 Ltr Ro , High Pressure Switch And Low Pressure Switch- These Are In Two Numbers Locations Are One Before High Pressure Pump And Another Is After. -For Suitable For 1000 Ltr Ro , Pressure Controlled Valvex -These Are In Two Numbers Locations Are One Before High Pressure Pump And Another Is After.-For Suitable For 1000 Ltr Ro , Flushing Switch With Solenoid Valve-Size : 3/4 Inch Working 230Volt Ac.-For Suitable For 1000 Ltr Ro , Electronic Panel Board - The Mains Supply Is Connected To The Panel Board. The Ro Is Controlled By The Panel Board. -For Suitable For 1000 Ltr Ro , Water Dispenser Machine(Water Atm)- (Atm)Aster Make With Digital Panel & Control Sensor And 100 Scratch Cards-For Suitable For 1000 Ltr Ro , Supplying Of Water Controller Sensor (Flot Type) At Site As Directed By Incharge Of Work. -For Suitable For 1000 Ltr Ro , Multiport Valve - Supplying Of Multiport Valve Manually Operational Required For The Pressure Sand Filter Including All Charges At Site As Directed By Incharge Of Work -For Suitable For 1000 Ltr Ro , Other Accecories - Providing Walls/ Ceiling/Floors, Medium C.P.V.C. (Chlorinated Poly Vinyl Chloride) Pipe Having Embossed Isi Mark On It, Of Required Diameter With Screwed / Plain Sockets, Joints, Necessary C.P.V.C. And Brass Fittings Such As Sockets, Back Nuts, Elbows, Bends, Tees, Reducers, Enlargers, Plugs, Clamps Etc. - For Suitable For 1000 Ltr Ro , Water Level Switch Providing Ball Cock Medium Type With Pvc Float Including Sockets And Necessary Fittings And Tested As Per Municipal Requirement, Testing Etc. Complete. 40Mm-For Suitable For 1000 Ltr Ro , Chiller -Cooling Capicity : 300 Lph Working Tempreture 25Degree To 15 Deegree.Cerculation Pump. Chiller Ms Stand. Working Full Automatic. Dry Run Indication - For Suitable For 1000 Ltr Ro , Stabilser -Working Up To Volt Single Phase 160V To 260V. 15Kva -For Suitable For 1000 Ltr Ro , Chiller Plumbing -Pvc Pipe Suitable Of 1000 Ltr Ro And Chiller -For Suitable For 1000 Ltr Ro , Green And Blue Garbage Tri-Cyle Rickshaw Color Green And Blue Seating Capacity 1 Maximum Run Unlimited Usage/Application Waste Collection Size/Dimension 250 Litre X 2 , Standard Aluminium Anodized Crutch Under Arm Crutches 1 Pieces Constructional Parameters Type Of Crutches Crutch Under Arm Crutch Tips Size 7/8 Inch Size Type Standard Size In Centimeter 60 Centimeter Material Of The Type Selected Aluminium Anodized Performance Parameters Type Of Hand Grip Na Height Of Rod Adjustable Upto (Centi Meter) 100 Centimeter Fitted With Non - Slip Rubber Shoe Yes Adujstable Rod Type Yes , Medium Aluminium Crutch Elbow Or Forearm Crutches 1 Pieces Constructional Parameters Type Of Crutches Crutch Elbow Or Forearm Crutch Tips Size 3/4 Inch Size Type Medium Size In Centimeter 50 Centimeter Material Of The Type Selected Aluminium Performance Parameters Type Of Hand Grip L Height Of Rod Adjustable Upto (Centi Meter) 86 Centimeter Fitted With Non - Slip Rubber Shoe Yes Adujstable Rod Type Yes , Plastic First Aid Kit With Medicines Crepe Bandage (Unit-1, Size: 6 Cm) Adhesive Bandage (Unite-1) Adhesive Bandage Round 25Mm (Unite-1, Size: 25 Mm) Pain Relief Gel (Unite-1) Povidone Iodine Ointment(Unite-1) Oral Clinical Thermometer (Unite-1) Antiseptic Liquid (Unite-1) Absorbent Cotton I.P. (Unite-1) Microporous Surgical Tape (Unite-1) Paracip/Parachoice (Unite-1) Gauze Swab (Unite-1) Roller Gauze Unite-1, Size: 7.5 Cm) A Pair Of Scissors (Unite-1, Size: Small) First Aid Leaflet Sticker (Unite-1) , Mortuary Cabinet Freezer Door Material Stainless Steel Refrigeration System- Unitary Type Rtu-06 Number Of Bodies 1 Trolley Material Stainless Steel Body Material Stainless Steel Technical Specification Integral Temperature Gauge Yes Electronic Temperature Indicator Cum Controller No Separate Doors And Handles For Each Chamber Yes Refrigerant Gas R134a Temperature Display Led Temperature Of Mortuary Cabinet(Degree Celsius) -15 Degc To 10 Degc Internal Lighting Vapor Proof Incandescent Lamp Insulation Thickness 50 Millimeter Locking System Standard Key Locks Trolley Sliding On Telescopic Rails No Defrosting Type Na Safety Alarm Visual Insulation Between The Walls High Grade Polyurethane Type Of Alarm Temperature Variation Alarm Internal Drainage Yes Air Circulation Forced Air Circulation Power Suppy Voltage,+/-10% 230 Volt Phase Single Phase Frequency 50 Hertz Dimension & Size Height 800 Millimeter Width 800 Millimeter Height With Cooling Unit And Plain Cement Concrete Platform 800 Millimeter Depth 2000 Millimeter , Pre School Uniform For Girls And Boys Including Tie , Socks And Shies In Anganwadi Center (Check Pattern In Colours As Per Buyers Requirements Description Pinafore With Embedded Collar And Sleeves For Anganwadi, Preschool Childrenutility Girls And Boys Size ( 1 To 5 Yrs Kids ) Dimensions And Pattern As Per Sketch And Dimension Chart For Icds Pre-School Uniforms- Pinafore With Embedded Collar And Sleeves For Children Of Anganwadi Centers In Mharashtra , Sketch And Dimensional Chart For Pre School Uniform- Pinafore Has Been Seen And Understood Yescollar Reinforcement With Reinforcementopening Opening At Back Upto Waist Portion With Buttonsbelt At Waist Portion As Per Buyers Requirementsnumber Of Loops For Belt2 Material-Pinafore Fibre Composition (Warp & Weft) Polyester Staple Fiber ( Psf ) - 70% And Viscose - 30% ( Tolerence ± 5% ) ( Test -Method Is: 3416 , Part - 1 ) Count Of Yarn, Warp (Ne) 2/30S ( Tolerence ± 5% ) ( Test Method - Is: 3442 ) Count Of Yarn, Weft (Ne)15S ( Tolerence ± 5% ) ( Test Method - Is: 3442 ) No Of Threads, Warp ( Ends Per Inch )46 (Tolerance + 5% / - 2.5%) No Of Threads, Weft ( Picks Per Inch ) 46 (Tolerance + 5% / - 2.5%) Mass ( Gram Per Sq Mtr ) 145 To 150 Gram ( Test Method - Is : 1964 ) Weave Plain Material- Sleeves| Top Portion Including Collar ( Embedded Stitched Shirt Fabric ) Fibre Composition - Warp 100% Polyester Filament Yarn ( Pfy ) Full Dull Roto Yarn Fiber Composition - Weft White Yarns - 100% Cotton, Colour Tex X 3, Polyester Stitches Per Dm 35 To 40 Raw Edges, If Any Shall Be Bound By Overlock Stitching Yes Colour Of Pinafore Any Other Colour As Per Buyers Requirement Colour/ Pattern Of Embedded Shirt Fabriccheck Pattern In Colours As Per Buyers Requirements Colour Fastness To Light Change In Colour 4 Or Better ( Test Method - Is : 2454 ) Colour Fastness To Washing Change In Colour 4 Or Better , Stain On Adjacent Fabric 3 - 4 Or Better ( Test Method - Test C (3), Is / Iso 105 - C10 ) Colour Fastness To Perspiration Change In Colour 4 Or Better , Stain On Adjacent Fabric 4 Or Better ( Test Method - Is : 971 ) Colour Fastness To Rubbing Dry 4 Or Better , Wet 3 Or Better (Test Method - Is : 766 ) Logo & Marking Logo Marking As Per Buyers Requirements Type Of Logo Embroidery Number Of Logos 2 Size, Design And Location Of Logo As Per Buyers Requirement Yes , Isi Mark Inverter Tubular Battry Battery Type: Tall Tubular Inverter Battery That Provides Many Years Of Service; Construction: Rugged Construction; Water Level Indicators: 6 Nominal Voltage: 12V; Rated Capacity At 27 Degree Celsius: 200 Ah; Electrolyte Volume: 19.90 Liter; Safety: Overload Protection With Auto Reset Dimensions Of The Container (L X W X H): 502Mm X 191Mm X 440 Mm Dry Battery Weight: 34.3Kg; Filled Battery: 59.0 Kg [Charging Current] Boost Mode Starting Current: 20.20; Boost Mode Finishing Current: 10.10;[Trickle Mode] Min: 168 Ma; Max: 672 Charging: Fast Battery Charging With Adaptive Battery Charging Control Technology Efficiency: Highly Efficient Battery Which Is Ideal For Heavy-Duty Application With Excellent Overcharge Tolerance, Superior Performance During Long Frequent Power Cuts, And Minimum Maintenance , Isi Mark Starter For 5 Hp Submersible Motor Pump Provided With 16 Amps Lt1 Type Contactor 4 Pole [Ac3 Motor Duty] With Easy Replaceable Heavy Duty Fixed And Moving Contacts And Coil Voltage Range Between 280-480 Volts With Easy Replacement Of Coil. Thermal Overload Relay Ensures Overload Protection And Manual Reset Facility [Range ?9~14 Amps For 5 Hp Motor Pump] Starter Provided With Red, Yellow And Blue Neon Bulbs For 3 Phase Power Indication. , Photo With Frame Standard Size For Office As Per Requirement Of Photo Like (Chhatrapati Shivaji Maharaj/Rajmata Jijau/Savitribai Fule/Mahatma Gandhi/Dr.Babasaheb Ambedkar Etc) , Foot Basic Sewing Machine Floral Face Plate And Arm Side Cover Round Stitch Indicator Plate Nickel Plated Needle Bar Auto Trimping Spring Loaded Bobbin Winder For Uniform Winding Of Bobbin Sheet Metal Bobbin Winder , Solar Hi Mast Complete 1 Set Of 20 Watt [20 Watt X 4 Light,Panel 75 Watt Panel X Qty, 20Ah Battery X4, 6 Hr Constand After 6Hr Dim With Motion Sensor =Total 12Hr Backup,Oct 6Mtr Pole, Foundation Bolt, Solar Panel Structure X 4, Light Arm X 4, Labour Charges, Foundation Materail, Wire] , All In One 9W Solar Street Light(Usage/Application Out Door Lighting Input Voltage 12 V Body Material Metal Lighting Type Led Ip Rating Ip55, Ip66 Lighting Color Cool White Lumens 1170 Features Inbuilt Battery And Solar Panel Battery Capacity 12.8 V 6 Ah Maximum Lumens 1170 Pole Height5-6 M Battery Voltage 12.8 Efficiency 95% Operating Temperature -40 C To 60 C Optical Cover Optical Lens Pv Module 30W Color Temperature Range 2700K-6500K Cri 70-82 Material Typemetal) , All In One 12W Solar Street Light(Usage/Application Out Door Lighting Input Voltage 12 V Body Material Metal Lighting Type Led Ip Rating Ip55 Lighting Color Cool White / Warm White Lumens 1560 Featuresinbuilt Battery And Solar Panel Battery Capacity 12.8 V 12 Ah Maximum Lumens 1560 Pole Height 5-6 M Battery Voltage 12.8 Efficiency 95% Operating Temperature -40 C To 60 C Optical Cover Optical Lens Pv Module 40W Color Temperature Range 2700K-6500K Cri 70-82 Material Type Metal) , All In One 15W Solar Street Light(Usage/Application Out Door Lighting Input Voltage 12 V Body Material Metal Lighting Type Led Ip Rating Ip55 Lighting Color Cool White / Warm White Lumens 2000 Featuresinbuilt Battery And Solar Panel Battery Capacity 12.8 V 15 Ah Maximum Lumens 2000 Pole Height 5-6 M Battery Voltage 12.8 Efficiency 95% Operating Temperature -40 C To 60 C Optical Cover Optical Lens Pv Module 40W Color Temperature Range 2700K-6500K Cri 70-82 Material Type Metal) , All In One 18W Solar Street Light(Usage/Application Out Door Lighting Input Voltage 12 V Body Material Metal Lighting Type Led Ip Rating Ip55 Lighting Color Cool White / Warm White Lumens 2000 Featuresinbuilt Battery And Solar Panel Battery Capacity 12.8 V 15 Ah Maximum Lumens 2000 Pole Height 5-6 M Battery Voltage 12.8 Efficiency 95% Operating Temperature -40 C To 60 C Optical Cover Optical Lens Pv Module 40W Color Temperature Range 2700K-6500K Cri 70-82 Material Type Metal) , Sliding Glass Notice Board Color Green, Blue, Red Board Material Softboard Core,Felt Frame Material Anodised Aluminium Frame Brand Indoh Boards Board Size (Inches) 24 X 48 With Frame Yes , Sliding Glass Notice Board Color Green, Blue, Red Board Material Softboard Core,Felt Frame Material Anodised Aluminium Frame Brand Indoh Boards Board Size (Inches) 60 X 90 With Frame Yes , Sliding Glass Notice Board Color Green, Blue, Red Board Material Softboard Core,Felt Frame Material Anodised Aluminium Frame Brand Indoh Boards Board Size (Inches) 90 X 180 With Frame Yes , Isi Mark Starter For 12 Hp Motor Pump Provided With 16 Amps Lt1 Type Contactor 4 Pole [Ac3 Motor Duty] With Easy Replaceable Heavy Duty Fixed And Moving Contacts And Coil Voltage Range Between 280-480 Volts With Easy Replacement Of Coil. Thermal Overload Relay Ensures Overload Protection And Manual Reset Facility [Range ?9~14 Amps For 5 Hp Motor Pump] Starter Provided With Red, Yellow And Blue Neon Bulbs For 3 Phase Power Indication. , Belan Polpat Belan Wooden Chapati Maker Circular Board With Rolling Pin Set Wooden Circular Board Hand Made , Flash Cards Learning & Education Game For Kids Alphabets 52 Cards With Pictures , Aluminium Patila Big 110 Ltr Technical Properties Height 14 Inchgrade Nathickness Lid 2 Inchstrong Handle Withdiameter 40 Inchmaterial Stainless Steeltype Patilathickness Body 3.5 Inchcapacity 110 Liter , Iron Kadhai 150 Litre Technical Properties Thickness Of Kadhai (Mm) 6 Outer Diameter Of Kadhai (Mm) 310 Depth Of Kadhai (Mm) 50 Diameter Of Handle Rod In (Mm) 5 Capacity Of Kadhai( In Litre) 150 , Flash Cards Learning & Education Game For Kids Alphabets 52 Cards With Pictures , Alpha Numeric Plastic Leeter World -Educational Toys For 3-8 Year Olds Girls Boys, 105 Pcs See And Spell Learning Toys, Matching Letter Spelling Game Sight Words Games Educational Preschool Toys , Kids Painting Set Including 1 Mini Pre- Drawn Canvas Panel With Easel And 6 Poster Colors Set With A Painting Brush For Kids Hobby Learning Painting Drawing Art And Craft Diy Sets Gift Sets, , Ceiling Cleaning Broom/ Multi Purpose Broom Stick (Spider / Cob Web) , Magical Handwriting Workbook(4 Book) With (1 Pen+4 Refill)Pen And Refills , 6 Puzzle Board - Birds,Flower, Vegetable Fruits, Transport And Animals (Multicolor) , Flexible Long Garden Water Pipe/Pvc Pipe/Garden Outdoors Pipes With Hose Connector Per Mtr , Chalk Multicolour Writing Chalk, 50 Chalk Sticks In The Box , Chalk White Or Single Colour Writing Chalk, 50 Chalk Sticks In The Box , 36 Pieces Alphabet & Number Floor Mats For Kids, Puzzle Eva Foam Mat For Children , Portable Foldable Wheelchairs For Handicap Patient Old People Children Manual Wheelchair (Self-Propelled Wheelchair) , Vacuum Cleaner Wet And Dry 1150-Watt Powerful Suction And Blower Function , Stethoscope Exterior Finish Brass;Chrome Item Dimensions Lxwxh 26 X 13 X 3 Centimeters Material Metal , Toy Counting Frame Plastic Approx: Width320 Mmheight440 Mm , Blanket (Dimension Approx Length Of The Blanket 230 Centimeter Width Of The Blanket 150 Centimeter Mass Mass 685 Gram Mass Per Blanket 2.3 Kilogram) , Round Table With Chair Set [Front Round Table,L54 X W30 X H20,Kids Chair L13 X W15.5,H20 X 5Qty] , Magnetic Board For Kids [2 Way Board One Sude White & One Side Black Board With Magnetic Alphabets & Number L15 X W20 X H54] , Commercial Slide Ladder (Preschool Kit) Virgin Polyethylene And Full Arch Shape , Sliding Glass Notice Board Color Green, Blue, Red Board Size (Inches) 24 X 48 With Frame Yes , Sliding Glass Notice Board Color Green, Blue, Red Board Size (Inches) 60 X 90 With Frame Yes , Sliding Glass Notice Board Color Green, Blue, Red Board Size (Inches) 90 X 180 With Frame Yes , Magazine Stand Revolving Made By Iron With Powder Coated Finish. Easy To Move. Having 16 Pockets. , Curtnes For Windows Material Silk Gsm Quality 300 Material Care Machine Wash,Hand Wash,Dry Clean Lining Included Yes Color As Per Grampanchayat Choice. Patterns Plain Fitting Eyelits Per Sq Mtr , Table Top Glass Thickness 12Mm Type Of Glass Toughened, Heavey, Break Resistance, Smooth, Sqr Per Feet , Stainless Steel Serving Tray (Large Size) For Serving Water And Dishes , Serving Tray Set Of 3 For Coffee/Tea/Breakfast(Printed Design) , Head Pins Fine Satin Pin Craft, Stainless Steel, 1 1/16 Inch Single Box 100 Pcs , Stamp Pad, 110 X 69 Mm - Violet/Red /Black Small , Stamp Pad 155 X95 Mm Violet /Red /Black Small Large , Mirror Plastic Frame Mirror In Square Shape With Shelf Display Area Of Mirror Is 8 Inch By 11 Inch Appx , No Dust Broom Xl For Floor Cleaning, Long Handle Broom Stick For Home Floor Cleaning , Electrical Needle Syringe Destroyer/Needle Destroyer For Hospital And Laboratory , Iron Patient Hospital Basic Examination Table 1830 Mm (L) * 575 Mm (W) * 850 Mm (H) , Iron Patient Hospital Bed Manual White Hospital Bed, Stainless Steel/ Iron With Coted, Size/Dimension: 3 X 6 Feet , Iron Patient Hospital Bed, Dimension: 2030X900x500mm Non Adjustable With Iv Rod , Thap Dhol (S.S),17.2 Inch, Silver Steel Drum Duga Nut & Bolts Dholak , Side Drum Steel 14 Inch With Belt, Stick And 2 Fiber Sheet Free Acoustic 1 Drum Kit Set (Professional, Student) , Standard Cotton Swing For Kids Baby Jhula Washable 1-8 Years With Safety Belt , Magic Speed Rubics Cube 3 * 3 * 3Puzzle(Size 2.5 Cube) , Alcohol Based Hand Sanitizer/Hand Cleanser 5 Ltr Can , Alcohol Based Hand Sanitizer/Hand Cleanser 500 Ml Sprey Bottle , Alcohol Based Hand Sanitizer/Hand Cleanser 100 Ml Sprey Bottle , Alcohol Based Hand Sanitizer/Hand Cleanser 50 Ml Sprey Bottle , Trolley Spekar Driver Type 2 Subwoofer, 2 Atellitesbt/Usb/Sd/Fm/2 Wireless Mike , 5 Layer 30 * 30 Inch Wall Mount Modern Kitchen Utensils Dish Rack Stainless Steel Kitchen Rack Utensil Rack Utensil Stand , Baby Weight Slater ( Hanging Scale Tubular Spring Balance Dynamo Meter Up To 5 Kg With 1 Baby Hanging Bag) , Mixer Grinder 550 Watts With 3 Multi Ouroose Grinding Jars Technical Specification: Voltage Supply 230 V Ac 50 Hz Motor Wattage550 Watts... Rating 30 Minutes. . Speed Control Switch 3 Peed With An Incher. Speed 1500 (Rpm) ( No Load). Body Material Abs Plastic .. Jar Material Stainless Steel .. Blade Material Stainless Steel . Dome Material Polycarbonate .. Rated Liquidizer Jar Capacity 1.50 Ltr. Rated Grinding Jar Capacity 150 Ml ... Normal Load 150 Gm Urad Dal Well Soaked In Water , Resilient Seated Cast Iron Double Air Relief Valves For Water Works Purposes Standard Type With In-Built Isolating Valve(Ds 1) Nominal Pressures Pn 1.6 Specificationconformity To Specification Is 14845:Latest Isi Marked Yes Material Material Of Stem High Tensile Brass-Hsb1 Material Of Low Pressure Seat Ring And Face Ring Epdm Material Of High Pressure Orifice High Tensile Brass Material Of Stem Nut High Tensile Brass Material Of Body Seat Ring Stainless Steel Material Of Bolts Stainless Steel Material Of Nuts Carbon Steel Material Of Gland Packing Jute Material Of Float(High Pressure Orifice) Timber Core With Rubber Coating Material Of Float Guide High Tensile Brass Dimension Nominal Size Of Single Air Valve(Small Orifice) S1 Na Nominal Size Of Single Air Valve(Large Orifice) S2 Na Nominal Size Of Standard Double Air Valve With In-Built Isolating Valve(Ds 1) Na Nominal Size Of Standard Double Air Valve Without Isolating Valve(Ds 2) Na Nominal Size Of Kinetic Air Valve(Dk) Na Direction And Colour Direction Of Operation Clock Wise Colour Black/Blue , Resilient Seated Cast Iron Single Air Relief Valves For Water Works Purposes Standards Specification Conforming To Standard As Per Is:14845 (Latest) Whether Product Is To Be Isi Marked? Yes Cml No If Isi Marked (Write Na If Not Isi Marked) Na Generic Valve Types Single Air Valve Temperature Rating Upto 45 Deg C Maximum Permissible Gauge Working Pressure(Mega Pascal) 1.6 End Connection For Single Air Valve Screwed Type According To Is:554 End Connection For Double Air Valve Flanged Type According To Is:1538 End Connection For Kinetic Air Valve Flanged Type According To Is:1538 Size & Dimension Nominal Size Of Single Air Valve 50 Millimeter Nominal Size Of Single Air Valve 50 Millimeter Nominal Size Of Kinetic Air Valve 50 Millimeter Material Body And Component Parts As Per Clause 9.1 Of Is:14845 (Latest) Coating Material Type B Of Is:341 (Latest) Body Thickness As Per Clause 10.2.4 Of Is:14845 (Latest) Float Diameter As Per Clause 10.5.1 Of Is:14845 (Latest) Marking Marking As Per Clause - 15 Of Is:14845 (Latest) , Swing Check Type Reflux (Non-Return) Valves For Water Works Purposes Type Type Illustration Of Reflux Valve With Inclined Seating And Side By-Pass Arrangement Specification Conformity To Specification Is 5312 (Part 1) Latest Product Is Bis Marked Yes Material Material Of Body , Door , Bearing Holder Grey Cast Iron Material Of Hinge Pin , Door Pin And Door Suspension Pin Stainless Steel Material Of Body Seat Rings Stainless Steel Material Of Door Face Ring Stainless Steel Material Of Bearing Bushes/Bearing Block P.T.F.E Material Of Plugs For Hinge Pin/Air Release Plug Stainless Steel Material Of Gaskets Compressed Asbestos Fibre Material Of Hinges Malleable Cast Iron Dimension Nominal Sizes Of Reflux Valve (Mm) 350 Type Of By-Pass Valves (As Per Is 778) Class 1 For Pn 1.0 Mpa , Rod 4 Feet Zig Zag , Rod 5 Feet Regular , Rod 1 Feet Regular , Standard 28Mm Rubber Weight Plates (2.5Kg, 5Kg, 7.5Kg, 10Kg, 15Kg, 20Kg, 25Kg, 30Kg, 35Kg, 40Kg ) Rate Per Kg For Any Pair Without Rod And Other Accessories , Dumbels Rubber Coated 2.5Kg, 5Kg, 7.5Kg, 10Kg, 15Kg, 20Kg, 25Kg, 30Kg, 35Kg, 40Kg ) Rate Per Kg For Any Pair Without Rod And Other Accessories , Multi Bench Premium(Chest, Leg, Curl, Leg Extension )3 In One , Leg Curl / Leg Extension Main Frame: Large Rounded Rectangular Pipe,Cushion: Made Of Pu,Shroud: Metal Shroud With One Step Injection Moulding, Seat Adjustment : 5 Level Adjustment System, Adjustable Range : 0-100Mm, Guide Rail : Made Of Alloy Steel, Pulley : Made Of Engineering Aluminium, Handlebar : Pvc, Weight Plate : Alloy Steel, Guide Rod : Stainless Steel Hollow Pipe, Steel Cable : Max Load 1000 Kgs, Passes 100,000 Rounds,Weight Stacks : 110 Kgs , Bicep Curl Machine ,Pulley: Cast Iron, Ø106x20mm, With Sealed Bearing, Cable: Steel Cable Ø3.5 Jacketed With Pvc Ø5.5Mm Outside Diameter, Powder Coating: 2 Rounds (Silver/Black/Dark Grey Varnish), Tube 1: Oval Elliptical Tube, 60*120Mm T.: 3Mm, Tube 2: Round Tube, Dia 90Mm T.: 3.0Mm, Weight Stack: Made Of Cast Iron, Stuffing: Pu Foam With Synthetic Leather, Wrap Around Gas Assist Seat Adjust, Unilateral Motion, Converging Axis, Right And Left Pre-Stretch Positioning, Contoured Upholstery With Lumbar Support, Size: (L)1000*(W)1500*(H)1600Mm Stack Weight 80Kgs-N.W.: 248Kgs , Adjustable Squat Rack Stand Material Alloy Steel, Product Dimensions ?23.54D X 41.8W X 59.5H, Style ?Adjustable, Item Weight16.32 Kilograms, Number Of Racks ?2, Weight Limit?600 Pounds , Calf Muscle Machine Product Dimensions 152.4D X 61W X 48.3H Cm, Frame Material ?Iron, Weight Limit ?250 Kg , Stepper With Riser For Gym Adjustable Height In 3 Steps:15Cm, 20Cm,25 Cm, Non Slip Top Surface, Dimension: 100 X 38 X 15/20/25Cm, Weight Apx. 8 Kg , Gym Dumbbell Rack Material Iron, Product Dimensions 45D X 40W X 60H Centimeters, Style ?Multi-Level, Item Weight ?17000 Grams, Number Of Racks ?3, Weight Limit ?1000 Kg. , Weight Plates Storage Rack For Gym Material ?Iron, Product Dimensions ?68D X 57W X 119H Cm, Style Weight Plate Tree, Item Weight?2Kg, Number Of Racks 6, Weight Limit 300 Kg, Frame Type Weight Plate Tree. , Yoga Mat For Women And Men Material ?Thermoplastic Elastomers, Product Dimensions 182L X 60W X 0.6Th Cm , Submersible Pump Solar Micro Pumping System Capacity 7.5 Hp Specifications: Model Number As Per Mnre Specification Model-Ii Motor Capacity 7.5 Hp, Pv Array (Wp)M Others, Shut Off Dynamic Head 45 Meter, Types Of Motor Pump Set, Submersible Pump, Pump Set Type, A.C. Induction Motor Pump Set With A Suitable Inverter Pv Array Operation Of Spv Pumping System The Spv Water Pumping System Should Be Operated With A Required Pv Array Capacity Measured Under Standard Test Conditions (Stc). Number Of Modules In Series And Parallel Could Be Used To Obtain The Required Pv Array Power Output24 ,The Power Output Of Individual Pv Modules Used In The Pv Array, Under Stc (In Watts Peak)335, Source Of Pv Module Indigenously Produced Pv Module (S) Containing Mono/ Multi Crystalline Silicon Solar Cells Efficiency Of The Pv Module (%)17 Fill Factor For Pv Module (%)70. Types Of Motor Pump Set Submersible Pump Pump Set Typen A.C. Induction Motor Pump Set With A Suitable Inverter, Numbers Of Poles Of Motor2 Motor Speed(In Rpm)2800. Bore Size 6 Inch, Delivery Size 2.5 Inch, Suction Head For Surface Pump 6 Meter, The Suction/ Delivery Pipe (Gi/Hdpe), Electric Cables, Floating Assembly, Civil Work And Other Fittings Required To Install The Motor Pump Set Yes, Inclusive Material Of Suction Pipe,Isi Marked Hdpe Pipe To Is 4985 Length Of Suction Pipe 45 Meter, Material Of Delivery Pipe Isi Marked Hdpe Pipe To Is 4985 Length Of Delivery Pipe 45 Meter, Pump Material Construction Of The Pump Be Made Using Parts Which Have A Much Higher Durability And Do Not Need Replacement Or Corrode For At Least 1 Years.Marking On Motor Pump The Following Details Should Be Marked Indelibly On The Motor Pump Set A) Name Of The Manufacturer Or Distinctive Logo. B) Model Number. C) Serial Number. , Usb Rechargeable Electric Gas Lighter For Kitchen Gas Stove(Windproof , Flameless, Smarter , Safer -Gas Lighter Chargeable Plasma Technology Generates A Windproof Plasma Annual Rate Contract Pulse Hotter Than Fire , Low Sound, Multi-Purpose Usage To Easily And Safely Fulfill All Your Lighting Needs ; No Butane , No Flame , A Eco Friendly , Cleaner , Easier And Safer Way To Light Usb Rechargeable -Long Lighter For Candle Plazmatic Lighter Comes With The Usb Cord , Could Be Charged With Any Usb Power Port ; Gets Fully Charged In About An Hour And Gives More Than 400 Sparks Or 3 Hours Of Use Per Charge ; Excellent Battery Life ,Multipurpose Use : Flexible Gas Lighter Ideal For Gas , Candles , Kitchens , Stovetops , Grill , Barbeque , Fireplaces , Fireworks , Lanterns , Fragrance Lamps , Pipes , Camping , Outdoors And Much More) , Standard 28Mm Rubber Weight Plates (2.5Kg, 5Kg, 7.5Kg, 10Kg, 15Kg, 20Kg, 25Kg, 30Kg, 35Kg, 40Kg ) Rate Per Kg For Any Pair Without Rod And Other Accessories Indoor Gym , Dumbels Rubber Coated Olympic 2.5Kg, 5Kg, 7.5Kg, 10Kg, 15Kg, 20Kg, 25Kg, 30Kg, 35Kg, 40Kg ) Rate Per Kg For Any Pair Without Rod And Other Accessories Indoor Gym , Multi Bench Premium(Chest, Leg, Curl, Leg Extension )3 In One Indoor Gym , Leg Curl / Leg Extension Main Frame: Large Rounded Rectangular Pipe,Cushion: Made Of Pu,Shroud: Metal Shroud With One Step Injection Moulding, Seat Adjustment : 5 Level Adjustment System, Adjustable Range : 0-100Mm, Guide Rail : Made Of Alloy Steel, Pulley : Made Of Engineering Aluminium, Handlebar : Pvc, Weight Plate : Alloy Steel, Guide Rod : Stainless Steel Hollow Pipe, Steel Cable : Max Load 1000 Kgs, Passes 100,000 Rounds,Weight Stacks : 110 Kgs Indoor Gym , Bicep Curl Machine ,Pulley: Cast Iron, Ø106x20mm, With Sealed Bearing, Cable: Steel Cable Ø3.5 Jacketed With Pvc Ø5.5Mm Outside Diameter, Powder Coating: 2 Rounds (Silver/Black/Dark Grey Varnish), Tube 1: Oval Elliptical Tube, 60*120Mm T.: 3Mm, Tube 2: Round Tube, Dia 90Mm T.: 3.0Mm, Weight Stack: Made Of Cast Iron, Stuffing: Pu Foam With Synthetic Leather, Wrap Around Gas Assist Seat Adjust, Unilateral Motion, Converging Axis, Right And Left Pre-Stretch Positioning, Contoured Upholstery With Lumbar Support, Size: (L)1000*(W)1500*(H)1600Mm Stack Weight 80Kgs-N.W.: 248Kgs Indoor Gym , Adjustable Squat Rack Stand Material Alloy Steel, Product Dimensions ?23.54D X 41.8W X 59.5H, Style ?Adjustable, Item Weight16.32 Kilograms, Number Of Racks ?2, Weight Limit?600 Pounds Indoor Gym , Calf Muscle Machine Product Dimensions 152.4D X 61W X 48.3H Cm, Frame Material ?Iron, Weight Limit ?250 Kg , Stepper With Riser For Gym Adjustable Height In 3 Steps:15Cm, 20Cm,25 Cm, Non Slip Top Surface, Dimension: 100 X 38 X 15/20/25Cm, Weight Apx. 8 Kg Indoor Gym , Gym Dumbbell Rack Material Iron, Product Dimensions 45D X 40W X 60H Centimeters, Style ?Multi-Level, Item Weight ?17000 Grams, Number Of Racks ?3, Weight Limit ?1000 Kg. Indoor Gym , Weight Plates Storage Rack For Gym Material ?Iron, Product Dimensions ?68D X 57W X 119H Cm, Style Weight Plate Tree, Item Weight?2Kg, Number Of Racks 6, Weight Limit 300 Kg, Frame Type Weight Plate Tree.Indoor Gym , Yoga Mat For Women And Men Material ?Thermoplastic Elastomers, Product Dimensions 182L X 60W X 0.6Th Cm Indoor Gym , Hbnc Kit For Asha Worker Including 1. (Baby Weighing Scale With Sling Dial Type Analogue Display Light Weight Portable 25Kg- 1Nos.). 2. (Digital Thermometer, Pocket Type, Digital Display-1 Nos.) 3.(Digital Timer, Led Display, 2 Size -1 Nos.) 4.(A Suitable Bag To Carry All Things (With Nhm Logo)- 1Nos.) 5.(Cotton 400Gm-1 Nos.) 6.( Gauzes Swab 7.5X7.5 Cm(1 Pack Of 50 Nos)-1 Nos) 7.( Soap And Soap Case-1Nos) 8.( Baby Blanket Locally Made, Woollen Type, Size 120Cm X90cm-1Nos) 9.( Palada/Spoon Stainless Steel-1 Nos) , Multicolour-4K, Matte Vinyl Stickers Educational Like (Abcd, Human Body Parts, Good Habits /Bad Habit Etc.)As Per Requirement Wall Stick Chart For Anganwadi Rate Per Sq Feet , Baby Gift Kit Items Included In The Gift Pack: 1) Baby Shampoo - 100 Ml, 2)Diaper Rash Cream - 20 Gm, 3)Baby Massage Oil - 100 Ml, 4) Gentle Baby Soap - 75 Gm, 5) Baby Lotion - 100 Ml, 6) Baby Powder - 100 Gm, 7) Gentle Baby Wipes 12 Pieces(20 X 21 Cm). Branded Himalaya/Mee Mee/Johnsons/The Moms Construction Of Etc , 1.5 Hp Table Top Atta Chakki Mini Flour Mill Specification:Weight Approx.28, Capacity Approx. 10 To 12 Kg, Stone Size 7 Inch X 20 Mm, Electric Motor 1.5 Hp Single Phase, Rpm 960 Rpm, Voltage 220 V, Power Consumption1.2 Unit, Type Semi Automatic. , Grid Connected Rooftop Solar System 1Kw Solar System Specification: Capacity1 Kw Solar Panel, Qty.335 Watt X 3 Nos., Solar Inverter1 Kw (On Grid) ,Accessories Complete Accessories Included Structure, Wires, Acdb/Dcdb, Etc. ,System Warranty 1 Years, Bidder Shall Enter Their Rates Including Panels, Inverter, Structure, Wires, Inclusive Of All Taxes And Other Required Accessories Considering A Standard Bom And On Site -All Installation Charges. , Grid Connected Rooftop Solar System 2 Kw Solar System Specification: Solar System 2 Kw, Solar Panel Qty. 335 Watt X 6 Nos., Solar Inverter 2 Kw (On Grid), Accessories Complete Accessories Included Structure, Wires, Acdb/Dcdb, Etc.,System Warranty 1 Years, Bidder Shall Enter Their Rates Including Panels, Inverter, Structure, Wires, Inclusive Of All Taxes And Other Required Accessories Considering A Standard Bom And On Site -All Installation Charges. , Grid Connected Rooftop Solar System 3 Kw Solar System Specification: Solar System 3 Kw, Solar Panel Qty. 335 Watt X 9 Nos., Solar Inverter 3 Kw (On Grid), Accessories Complete Accessories Included Structure, Wires, Acdb/Dcdb, Etc.,System Warranty 1 Years, Bidder Shall Enter Their Rates Including Panels, Inverter, Structure, Wires, Inclusive Of All Taxes And Other Required Accessories Considering A Standard Bom And On Site -All Installation Charges. , Grid Connected Rooftop Solar System 5 Kw Solar System Specification: Solar System 5 Kw, Solar Panel Qty. 335 Watt X 15 Nos., Solar Inverter 5 Kw (On Grid), Accessories Complete Accessories Included Structure, Wires, Acdb/Dcdb, Etc.,System Warranty 1 Years, Bidder Shall Enter Their Rates Including Panels, Inverter, Structure, Wires, Inclusive Of All Taxes And Other Required Accessories Considering A Standard Bom And On Site -All Installation Charges. , Clorine Dosing Machine Without Stand By System Chemical Dosing System Consists Of 150 Ltr Tank Mounted On Ms Frame With Pump System With Upvc Piping. Imd-50 Flow Rate 0-50 Ltr Per Hour (1 Working Machine Only ) With Agitator Mixer Mounted On Tank Specification : 0.5Hp 3 Phase Motor With 0.5Hp Worm Gear Assemble Suitable Shaft. (System Make : Iflow) , Clorine Dosing Machine With Inbuilt Stand By System Chemical Dosing System Consists Of 150 Ltr Tank Mounted On Ms Frame With Pump System With Upvc Piping. Imd-50 Flow Rate 0-50 Ltr Per Hour (1 Working Machine Only ) With Agitator Mixer Mounted On Tank Specification : 0.5Hp 3 Phase Motor With 0.5Hp Worm Gear Assemble Suitable Shaft. (System Make : Iflow) , Isi Mark Submersible Rope Yellow Borewell Submersible Pump Rope,Poly More Virgin And Braided Twisted Cord Twine Rope String (16 Mm,Per Meter Meter) , Aluminium Armoured Power Cable-50 Sq Mm 3.5 Core Product Category Aluminium Power Cable, Size Of Conductor 50 Sq Mm, Core 3.5 Core, Conductor Material Aluminium, Colour Black, Overall Diameter (Strip/Wire) 29.5 Mm / 27.9 Mm, Current Rating 140 Amp, Thickness Of Pvc Insulation 1 Mm, Min.Thickness Of Pvc Inner Sheath 0.3 Mm, Nominal Dimensions Of Armoui (Strip / Wire) 4 X 0.8 Mm, Min. Thickness Of Pvc Outer Sheath (Strip / Wire) 1.56 Mm, Max Dc Resistance Ohm 0.641 Ohm, Max. Ac Resistance Ohm 0.82 Ohm, Approx. Reactance At 50Hz Ohms/Km 0.08, Capacitance Mfd/Krr 0.24 , Stainless Steel Kitchen Pincers/Sandshi/Pakkad Style Modern, Product Dimensions 26.5L X 1W Cm, Item Weight ?160 Grams. , 1.5 Hp Table Top Atta Chakki Mini Flour Mill Specification:Weight Approx.28, Capacity Approx. 10 To 12 Kg, Stone Size 7 Inch X 20 Mm, Electric Motor 1.5 Hp Single Phase, Rpm 960 Rpm, Voltage 220 V, Power Consumption1.2 Unit, Type Semi Automatic. , Baby Gift Kit Items Included In The Gift Pack: 1) Baby Shampoo - 100 Ml, 2)Diaper Rash Cream - 20 Gm, 3)Baby Massage Oil - 100 Ml, 4) Gentle Baby Soap - 75 Gm, 5) Baby Lotion - 100 Ml, 6) Baby Powder - 100 Gm, 7) Gentle Baby Wipes 12 Pieces(20 X 21 Cm). Branded Himalaya/Mee Mee/Johnsons/The Moms Construction Of Etc , Multicolour-4K, Matte Vinyl Stickers Educational Like (Abcd, Human Body Parts, Good Habits /Bad Habit Etc.)As Per Requirement Wall Stick Chart For Anganwadi Rate Per Sq Feet , Pvc Pipe Cid Joint Rubber Ring For Pipe Line Material Rubber, Pvc Pipe, Structure Pipe, Hydraulic Pipe Brand, Bew Surface Finish, Paint Coated, Cid Joint Size Up To 1000Mm, 3 4 2.5 6 , Cast Iron Detachable Joints Material Ci Application, Pvc Pipe, Structure Pipe, Hydraulic Pipe Brand, Bew Surface Finish, Paint Coated, Cid Joint Size Up To 1000Mm, 3 4 2.5 6 , Stainless Steel Bowl/Vati/Katori-Size5- (9.5Cm Wide)(Capacity 150 Ml)
Contract Date: Dec 31, 2025 Contract Value : 1.57 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
40.
Educational and Research Institute #8295208 AOC
Nit For Supply Of Surgical Items At Rims, Ranchi , Surgical Items : , Absorbable Gelatine Spoons Tampon Size 80Mm X 30Mm , Absorbent Cotton Roll, 400Gm Nett , Absorbent Cotton Roll, 500Gm Nett , Air Cushion , Air Way Disposable (Different Size) , Ambu Bag (Adult Size ) 100% Silicon Material Only , Ambu Bag (Neonatal Size ) 100% Silicon Material Only , Ambu Bag (Paediatric Size ) 100% Silicon Material Only , B.P Blade (Size 10 To 24) , Bain Circuit (Pediatrics Size) , Bandage Than (100Cm X 20 Mtr) As Per Schedule F-Ii , Bandage Than (90Cm X 18 Mtr) As Per Schedule F-Ii , Banin Circuit (Adult Size) , Bed Pan (Plastic) , Blood Lancet , Blood Line Tubbing Set , Blood Transfusion Kit , Consist Of B T Set, I V Canulla, Canulla Fixator, Syringe With Needle 5Ml, Alco Swab , Bone Wax , Catheter Introducer , Central Line F (Femoral Double Lumen Size 7, Length 20 Cms, Usfda Approved) , Central Line F (Femoral Tripal Lumen Size 7, Length 20 Cms,Usfda Approved) , Colo Bag , Colostomy Kit , Crepe Bandage 4 Inch , Crepe Bandage 6 Inch , Disposable Face Mask ( 3 Layer) , Disposable Gloves For Examination - Poly, Non Sterile , Disposable Gloves For Examination - Powder Free, Odourless ,Non Sterile , Disposable Nurses Cap , Disposable Shoe Cover , Disposable Surgeon Cap , Disposable Syringe With Needle(Non Reusable) 10Ml , Disposable Syringe With Needle(Non Reusable) 20Ml , Disposable Syringe With Needle(Non Reusable) 2Ml , Disposable Syringe With Needle(Non Reusable) 3 Ml , Disposable Syringe With Needle(Non Reusable) 5Ml , Disposable Syringe Without Needle(Non Reusable) 50Ml , Disposable Tuberculin Syringe , Double Lumen Femoral Catheter , E.C.G Jelly - 250 Gm , E.C.G Jelly - 5 Kg Jar , E.C.G Paper Size 280Cm X 215Cm , E.E.G Paste 250 Grm , Ecg Paper 3 Channel 80Mmx20mtrs , Elastic Adhesive Bandage Size 10Cm 4/6 Mtr. (Stretched Length) , Electrodes For E.C.G. , Endotracheal Tube Disposable - Pvc , Cuffed 2.0 To 10.0 , Endotracheal Tube Disposable - Pvc , Plain 2.0 To 5.0 , Enema Can , Et Tube All Size , Eye Drape , Femoral Catheter , Gauge Than(18Mtr X 90Cm) As Per Schedule F-Ii , Gluco Strip(Glucometer Need To Besupplied Free Of Cost,Usfda Approved ) , Hot Water Bag (1Ltr Cap) , I.V. Cannula Fixator With Semipremeabke Transparent Flim With Pad , Ice Caps , Ice Caps , Laryngoscope With Disposable Blades O Should Meet International Quality Standards.O Equipment Should Have Anti Fog Lens And White Led Light Sourceo Monitor Should Have Video Output Capability To Be Compatible With External Monitor And Recording Devices.O It Should Work On Common Batteries And Can Be Used Continuously For More Than 1 Hour.O The Disposable Blade Should Have Design To Provide Minimal Lifting Of Soft Tissue And Impact On Teeth During Laryngoscopy And Intubation. Display Monitor Can Be Attached To The Blades. O It Should Be Supplied With Disposable Blades 10 Each Of Both Channelled And Non-Channelled Blades.O Should Have Iso And Ce Marks Confirming To International Standards Of Safety , Leucoplast 4X5mtr , Macintosh Sheet , Metal Skin Staple Extractor , Mini Vac Set , Nasal Oxygen Catheter , Nubulizer Tubing Mask Adult & Pediartic , Paediatric Drip Set , Pediatric Breathing Circuit Disposable , Plain Rubber Catheter , Quinke Type Spinal Needle, Size 25 For Adult , Quinke Type Spinal Needle, Size 26 For Adult , Quinke Type Spinal Needle, Size 27 For Adult , Ryles Tube -Pvc Adult Size , Ryles Tube -Pvc Paediatric Size , Ryles Tube -Pvc With Silicon Elastometer Coating -Adult Size , Ryles Tube -Pvc With Silicon Elastometer Coating -Paediatric Size , Scalp Vein Set (Different Sizes) , Silicon Foleys Catheter All Size , Sterile Gauze Swab- 12 Ply , Sizes- 10Cm X 10Cm , Sterile Gauze Swab- 12 Ply , Sizes- 5Cm X 5Cm , Sterile Gauze Swab- 12 Ply , Sizes- 7.5Cm X 7.5Cm , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 6.0 , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 6.5 , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 7.0 , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 7.5 , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 8.0 , Surgeon Gloves (Latex,Sterile,Isi Marked) Size 8.5 , Surgeon Gloves (Sterile, Powder Free & Polymer Coated) Size 6.0 To 8.0 , Surgeons Gloves (Latex Resuable,Sterile,Isi Marked) Size 6.0 To 8.5 , Three Way Catheter , Tube Extension For 3 Way Stop Cock, 10Cm , Ultrasound Jelly 250 Gm , Ultrasound Jelly 5 Kg Jar , Urinal ( Plastic) , Urine Collection Bag - With Hanger & Bottom T-Type Outlet (For Adult) , Urine Collection Bag - With Hanger (For Paediatric) , Water Bed , Disposable Semiautomatic Biopsy Instruments Kit. ; Having Dual Penetration Throw 10Mm And 20Mm. ; Should Be Available With One Gauge Lower Compatible Coaxial Needle With Fire Ready Indicator. ; Should Be Available With A Blunt Tip Needle. Sizes Are- 18Gx16cm, 18Gx10cm, 20Gx16cm ; Should Be Us Fda And Ce Approved , Straight Supraglottic Airway ; O It Should Be Straight, Designed For Use Both In Anaesthesia And Emergency Medicine ; O Cuff And Airway Tube Should Be Moulded As A Single Unit For Safety - No Separation ; O The Cuff Should Have Reinforced Tip To Avoid Kinking During Insertion ; O The Pilot Balloon Should Provide Mask Size & Tactile Indication Of Degree Of Inflation ; O It Should Allow Placement Of Maximum 6.5 Et Tube Through The Airway ; O It Should Have Depth Marks For Monitoring Correct Positioning Of The Mask ; O It Should Provide Maximum Intra-Cuff Pressure Of Up To 60 Cmh20 ; O It Should Have 15 Mm Male (Iso) Airway Connector ; O It Should Be Disposable, Eliminating Chances Of Cross Contamination ; O It Should Be Made Of 100% Latex-Free Medical Graded Material ; O Should Be Available In All Standard Sizes To Accommodate Any Age Group Of Patients ; O It Should Be Mr Safe ; O Should Be Us Fda, Ce & Iso Certified For Quality Assurance , Hme Bacterial Filter , Micro Drip Infusion Seto Micro Drip Infusion Set With Drop Size Reduced To 60 Drops Per Ml For Paediatric And Critical Therapy. ; O Manufactured From Non-Toxic, Clear And Transparent P.V.C. Material. ; O Sharp Piercing Spike For Easy Insertion In Fluid Container Along With Built-In Preventive Bacterial Air Vent. ; O Infusion Set Has A Cylindrical Collapsible Drip Chamber For Proper Visualization Of The Drop Rate. ; O Provided With Disc Type Fluid Filter To Filter Any Particulate Matter In The I.V Fluid. ; O Long Super Smooth Kink Resistant Tubing With Efficient Roller Controller For Accurate And Unrestricted Flow. ; O Y Type Injection Port Made Up Of Silicone Provided For Extra Medication. ; O Luer Lock Connector For Secure Fitment To All Standard Devices. ; O Sterile And Individually Ribbon Packed. , 0.1 Gperaceticacid ; Other Ingredients : Corrosion Inhibitors, Surfactants, Stabilising Agents, Excipients. Hydrogen Peroxide, Acetic Acid ; Passes En 13624, En 13727, En 14348, En 14347, En 14476 Standards , 100 G Of Granules Contain The Following Active Ingredients: 43 G Sodium Per Carbonate, 22 G Tetraacetylethylenediamine. ; Passes En 13624, En 13727, En 14348, En 14561, En 14562, En 14563, En 13704 And En 14476 Standards, , 205 Disposable Hose , 316L Stainless Steel,Endo Mechanical Angled Head Contains 35 Staples Staplers , 5 Leads Ecg Limb Leads , 60Mm Disposable Linear Cutter Stapler , 80Mm Disposable Linear Cutter Stapler , 900Mr805electrical Adaptor - Dual Heated, Rt Circuits , 900Mr869probe, Airway Temp & Flow, For Use With 1.5M Circuits . With Right Angle Connector, , 900Pt913filter For Airvo 2, Pack Of 2 , Abdominal Drainage Kit O Specially Designed Kit For Post-Operative Abdominal Drainage. ; O Consists Of Super Smooth Drainage Catheter Along With A Collection Bag. ; O Made From Non-Toxic And Non-Irritant Medical Grade Pvc. ; O Provided With Specialised Foldable Handle Which Holds The Tube Upright, Prevents Accidental Kinking During Handling And Suitable For Bedside Hanging. ; O Soft And Smooth Catheter With Large Atraumatic Eyes For Efficient Drainage. ; O Radio-Opaque Line Throughout Catheter Length Help X-Ray Visualization. ; O Catheter Is Colour Coded For Instant Size Identification. ; O Sterile, Individually Packed In A Peelable Pouch. Size: 16Fg/20Fg/24Fg/28Fg/32Fg , Abdominal Pad / Gauze Sponge With X-Ray Thread,12 Ply Different Size 20 Cm X20cm , Abdominal Pad / Gauze Sponge With X-Ray Thread,12 Ply Different Size 25 Cm X25cm , Abdominal Pad / Gauze Sponge With X-Ray Thread,12 Ply Different Size 30 Cm X30cm , Abdominal Pad / Gauze Sponge With X-Ray Thread,12 Ply Different Size 45 Cm X45cm , Absorbable Gelatine Sponge Piles Pack Tampon ,80Mm*30Mm , Absorbable Gelatine Sponge,80Mm*50Mm*10Mm , Act Tube , Acumen Iq Sensor: A. It Must Be Compatible With Hamo Sphere Monitor. B. It Must Able To Provide Co,Ci,Svv,Ppv,Sv,Svi,Svri,Svr, Hypotension Prediction Index, Dp/Dt, Eadyn. , Adhesive Plaster (10Mtr X 7.5 Cm) , Adult Bp Cuff , Adult Bp Cuff , Adult Diapers- Extra Large , Adult Diapers-Large , Adult Diapers-Medium , Adult Electrodes With Mvp Gel For Zoll Defibrillator , Aerogene Pro Adult Tee With Silicone Plug (Autoclavable) (Pkt 5) , Aerogene Pro Control Module Kit - International , Aerogene Pro Filler Cap (Pkt 5) , Aerogene Pro Mask Kit Intl (Inc. Vented Elbow & 22 Mm F/22 Mm M Elbow) (Autoclavable) (Pkt 5) , Aerogene Pro Nebuliser Assembly , Aerogene Pro Paediatric Tee With Silicone Plug (Autoclavable) (Pkt 5) , Aerogene Pro Usb Controller Starter Kit , Aerogene Pro-X Controller Only , Aerogene Solo Single Patient Use Mask Kit Intl (Pack Of 5) , Aerogene Solo Single Patient Use Vented Elbow (Pack Of 5) , Aerosol Oxygen Mask Adult/Ped , Air Cushion Mask , Airway Sets Combi Tube Sets Size Fr.37 , Airway Sets Combi Tube Sets Size Fr.38 , Airway Sets Combi Tube Sets Size Fr.39 , Airway Sets Combi Tube Sets Size Fr.40 , Airway Sets Combi Tube Sets Size Fr.41 , Anaesthetic Tube Holder , Anatomically Curved Supraglottic Airway O It Should Be Anatomically Curvedfor Fast And Easyinsertiono The Cuff Should Have Reinforced Tip To Avoid Kinking During Insertiono Cuff And Airway Tube Should Be Moulded As A Single Unit For Safety - No Separationo The Pilot Balloon Should Provide Mask Size & Tactile Indication Of Degree Of Inflationo It Should Allow Placement Of Maximum 7.0 Et Tube Through The Airwayo It Should Have Depth Marks For Monitoring Correct Positioning Of The Masko It Should Have D-Shaped Airway Tube Design For Firm Grip During Insertiono It Should Provide Maximum Intra-Cuff Pressure Of Up To 60 Cmh20o It Should Have 15 Mm Male (Iso) Airway Connectoro It Should Be Disposable, Eliminating Chances Of Cross Contaminationo It Should Be Made Of 100% Latex-Free Medical Graded Materialo It Should Be Mr Safeo Should Be Available In All Standard Sizes To Accommodate Any Age Group Of Patientso Should Be Us Fda, Ce & Iso Certified For Quality Assurance , Anesthesia Circuit O A Co-Axial Modification Of The Basic T-Piece System, Developed To Facilitate Scavenging Of Waste Gases. ; O The Process Includes Patient Inspiring Fresh Gas From The Outer Reservoir Tube And Expiring Into Reservoir Tube. ; O Convenient, Lightweight Anesthesia Delivery System. ; O It Is Based On Mapleson D System, Provided With A Corrugated Tube, Expiratory Valve And Antistatic Bag. ; O The Modification Improves Clinical Utility. ; O It Is Simpler, Has Single Tube Convenience And Low Resistance To Breathing. ; O Compact And Inexpensive With Low Dead-Space. ; O Sterile And Individually Packed. , Annuloplasty Ring , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 7.5X7.5 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified.Usage- Upto 7 Days. Size- 10X10 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 12.5X12..5 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified.Usage- Upto 7 Days. Size- 23X23 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 17.5X17.5 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 10X20 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 10X25 Cm , Antimicrobial Five Layered Highly Absorbent Foam Dressing With Activated Carbon And Sliver Content 1.2Mg/Cm2, Active Release For 168Hrs (7 Days) With Self Adherent Borders And With Soft-Silicone Safetac Wound Contact Layer For Atraumatic Dressing Removal. Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 10X30 Cm , Arotic Cannula , Av Cassette Blood Lines Adults + Filtrate Line(A/V 143 Ml) , Ayre”S Spatula For Cervical Pap Smear – Sterile Ayre Spatula, Wood / Plastic Lenght: 18 Cm / 18.8 Cmindividually Packed In Sterile Pouch, In Box Of 100 , Baby Delivery Cloth/Kit , Baby Drapefor All Kind Of Surgeries N Baby . Translucent Sof Poly Film Size 1.2 X 1.2M Incise Area 25 X 20Cm Eto Sterlized. 5Year Expiry Self Life. Packing Material 45Gsm Polypropylene One Side And Another Side Tyvek Paper Packing. , Bacteria Filter Membrane , Bacteria Filter Membrane , Baladder Wash Syringe , Balloon Frontal Sinus Kits(Each Kit Consist Of 1 Balloon, 1 Guide Catheter ,1 Latch,1 Illumination Wire) , Balloon Maxillary Sinus Kits(Each Kit Consist Of 1 Balloon, 1 Guide Catheter ,1 Latch,1 Illumination Wire) , Balloon Sphenoid Sinus Kits(Each Kit Consist Of 1 Balloon, 1 Guide Catheter ,1 Latch,1 Illumination Wire) , Bcd With Delvido , Big Knife For Grossing Tissue , Biological Indicator , Biopatch Protective Disc With Chg - Biopatch Antimicrobial Dressing,1 Disk (2.5 Cm) W/4.0 Mm Center Hole , Biopatch Protective Disc With Chg - Biopatch Antimicrobial Dressing,1 Disk (2.5 Cm) W/7.0 Mm Center Hole , Biopatch Protective Disc With Chg - Biopatch Antimicrobial Dressing,3/4 Disk (1.9 Cm) W/1.5 Mm Center Hole , Bipolar Forceps Handle Flat & Insulated , Bladeless Trocars With Tissue Separatingflap - 10Mm Contain- Two 10Mmo100mm Sleeve/Cannula And One 10 Mm Obturator , Bladeless Trocars With Tissue Separatingflap - 12Mm Contain- Two 12Mmo100mm Sleeve/Cannula And One 12 Mm Obturator , Bladeless Trocars With Tissue Separatingflap - 5Mm Contain- Two 05Mmo100mm Sleeve/Cannula And One 05 Mm Obturator , Blood Transfusion Set O Conforms To Iso 1135-4 Standard. ; O Sharp Non-Vented Spike Suitable For Blood Bags And All Type Of Standard Blood Containers. ; O Provided With A Cylindrical Drip Chamber With 200? Filter To Prevent The Passage Of Any Clot Into The Chamber. ; O Flash Ball Type Injection Port For Extra Medication. ; O Comes With Smooth 150 Cm Long, Kink Resistant Tube. ; O Efficient Roller Controller For Accurate Adjustment Of Transfusion Rate. ; O Sterile, Individually Packed. , Bone Cement , Bone Cutter , Bone Marrow Aspiration Needle ; Jamshidi Bone Marrow Aspiration Needle ; Sizes Are- 18G And 15G ; Should Be Us Fda And Ce Approved. , Bone Marrow Aspiration Needle –Metal,Reusable , Salah Type With Component Includingtrocar , Cannula & Adjustable Side Guard, Size –No 14 , No – 16 & No – 18 G , 5 Cm Longneedle , Bone Marrow Biopsy Needle Should Be T-Handle With Trocar-Tapered Stylet Point And A Triple -Crown Cannula Tip. ; Sizes:- 13G X 9Cm, 11G X (10Cm/15Cm) And 8G X (10Cm/15Cm).Should Be Us Fda And Ce Approved. , Bone Marrow Biopsy Needle- Ergonomic Handle.Material : Stainless Steel, Remover Guide Provided With Indicators To Facilitate The Sample, Expulsion And That Allows,Samples Length Check, Provided With A Special Lock For A Safe Removal Of The Sample , Bone Marrow Biopsy Needle ; Original Jamshidi With Sharp Bevel Tip. ; Sizes:- 13G X (5Cm,9Cm), 11G X (10Cm, 15Cm) And 8G X 10Cm. ; Should Be Us Fda And Ce Approved , Bone Marrow Needle No.16 , Bone Marrow Needle No.18 , Brain Biopsy Cannula (Needle) Diff Diameter , Breathing Exercisero Breathing Exerciser. ; O Innovative System To Exercise Respiration Through Inspiration. ; O Specially Designed With 3 Stage Chambers To Provide For Efficient Exercise To Patient On A Step Up Basis. ; O Device Comprises Of Base Plate With Central Part Containing Volume ; Designated Three Chambers With A Colored Sphere. ; O The Central Part Is Attached To A Kink-Resistant Tube With A Mouth Piece With An Integrated Filter. ; O Three Spheres Rise Proportionately To The Inspiration Exerted By The User. ; O Innovative Design, Can Be Dismantled Into Parts For Cleaning And Disinfection. ; O Non Sterile, Individually Packed In A Box , Bulb Irrigation Syringe O Bulb Irrigation Syringe. ; O Syringe Barrel Manufactured From Pp And Adjoining Bulb From Tpe. ; O Indicated For Varied Applications Like Wound Cleansing, Urinary Bladder Irrigation, General Medical Or Surgical Irrigation, Suction Applications And Feeding Or Aspiration. ; O Syringe Consists Of Catheter Mount Centric Nozzle Which Is Compatible To ; Catheter Connectors. ; O Tapered Tip Facilitates Easy And Safe Connection To Any Catheter Or Gastric Tube. ; O Finger Flanges On The Syringe Help In Firm Grip And Facilitate Controlled And ; Precise Pumping. ; O Flanges Also Prevent Accidental Roll-Over Of The Syringe. ; O Soft Transparent Bulb Facilitates Easy Pumping And Suction. ; O Sterile, Individually Packed In A Peelable Pouch. , Bupivacaine Injection 0.5% (Glass Vial) , Bvf Filter Adult , Bvf Hme Filter Adult , Bvf Hme Filter Paed , Cabg Kit 1. Cardio Drape - 1Nos. Material: 77Gsm Sms Non-Woven Porus One Side Another Side Laminated. Cautery Bag 4Inbuilt Incise Drape With Iodine Adhesive Coating. Inbuilt Water Proof Laminated Drape Size 1.20M X 1.20M Drape Size : 2.4M X 4.1M. 2. Main Drape (U Split With Perineal Drape) 1 Nos. Material:Sms Non Woven Laminated Drape. Size240x 260Cm. 3.Under Patient Sheet. 1Nos. Material : Water Proof Sms Non Woven Fabric. Size: 140X 180Cm. 4. Adhesive Towel2 Nos. Material : Sms Non Woven With 2 Adhesive Strip. Size: 100X100cm. 5. Shoe Cover. 1Nos.6. Feet Holder. 1Nos. 7. Hand Towel 4 Pcs. 8. Full Gown Eco Wrap Around2nos.Sterlized Pack. Packing Material 45Gsm Polypropylene One Side And Another Side Tyvek 25Gsm Paper Packing. 5Years Expiry Life. , Catheter Mount O Specialised Catheter Mount With Double Ports For Specific Application. ; O Corrugated Tube Made Up Of Medical Grade Pe Offers Durability, Flexibility And Strength. ; O Double Flip Tap Cap With Seal Having Provision For Both Bronchoscopes As Well As For Suctioning. ; O Opening The First Tab On The Cap Allows For The Introduction Of A Bronchoscope Whilst Maintaining Airway Pressure And Opening The Second Tab Allows For Suctioning If Required. ; O Double Swivel Elbow With 15 Mm I.D. / 22 Mm O.D. Connector Fits All ; Standard Tracheal Tubes. ; O 22 Mm Standard Female Connector Is Compatible With All Breathing And Ventilator Circuits. ; O Sterile And Individually Packed. , Central Cath Arterial Line All Size , Chest Valve , Chiba Needle ; Sizes Are- 18Gx15cm, 18Gx20cm, 20Gx10cm, 20Gx15cm, 20Gx20cm ; Should Be Us Fda And Ce Approved , Chromic Gut Suture, With Needle, Size 1, 100Cm, 1/2 Circle Rb Heavy 50Mm , Chromic Gut Suture, With Needle, Size 1, 100Cm, 1/2 Circle Rb Mayo 45Mm , Chromic Gut Suture, With Needle, Size 1, 152Cm, 1/2 Circle Rb Heavy 40Mm , Chromic Gut Suture, With Needle, Size 1, 76Cm, 1/2 Circle Rb Heavy 40Mm , Chromic Gut Suture, With Needle, Size 1-0, 100Cm, 1/2 Circle Rb Mayo 45Mm , Chromic Gut Suture, With Needle, Size 1-0, 152Cm, 1/2 Circle Rb 30Mm , Chromic Gut Suture, With Needle, Size 1-0, 76Cm, 1/2 Circle Rb 30Mm , Chromic Gut Suture, With Needle, Size 1-0, 76Cm, 1/2 Circle Rb 40Mm , Chromic Gut Suture, With Needle, Size 2, 100Cm, 1/2 Circle Rb Mayo 45Mm , Chromic Gut Suture, With Needle, Size 2, 152Cm, 1/2 Circle Rb Mayo 45Mm , Chromic Gut Suture, With Needle, Size 2-0, 76Cm, 1/2 Circle Rb 30Mm , Chromic Gut Suture, With Needle, Size 2-0, 76Cm, 1/2 Circle Rb 40Mm , Chromic Gut Suture, With Needle, Size 3-0, 76Cm, 1/2 Circle Rb 20Mm , Circuit Adaptors Size 15M/22F , Circuit Adaptors Size 22F/22F , Clinical Thermometer, Oval , Clinical Thermometer,Oval , Clip Sensor , Closed Luer Iv Access System , Closed Port Device (Needle Less Connector):Needless Iv System With Closed Luer Access Having Self Sealing Silicone Split Septum With15cm Extension Set Bi& Tri (Not Reverse Septum) And Transparent Housing. Sizes: Plain, 15Cm Macro Bore Ext Set , Closed Port Device (Needle Less Connector):Needless Iv System With Closed Luer Access Having Self Sealing Silicone Split Septum With15cm Extension Set Bi& Tri (Not Reverse Septum) And Transparent Housing. Size: 15Cm Macro Bore Bi - Ext Set , Closed Port Device (Needle Less Connector):Needless Iv System With Closed Luer Access Having Self Sealing Silicone Split Septum With15cm Extension Set Bi& Tri (Not Reverse Septum) And Transparent Housing. Size: 15Cm Macro Bore Tri - Ext Set. , Closed Suction Systemo Closed Suction System Minimizes The Vap Incidences In Ventilated Patients. ; O Offers Convenience Of Attachment To Ventilator On One Side And Tracheal Tube On The Other, Resulting In Seamless Access Of Tracheo-Bronchial Cavity. ; O Dual Swivel Elbow Offers Convenience Of Rotatability For Optimal Comfort. ; O Atraumatic, Soft Catheter Minimizes The Damage To Mucosal Membranes. ; O Clear Depth Markings Help To Reduce Mucosal Trauma And Infection Potential By Allowing The Practitioner To Limit The Distance Of Catheter For Safe Suctioning. ; O Catheter Comes In A Protective Sleeve Which Completely Isolates It From Direct Contact To Caregivers And Avoids Disturbances. ; O Thumb Control Facility At The Proximal End Prevents Inadvertent Suctioning. ; O Provided With Separate Ports For Flushing And Mdi Administration. ; O Day-Of-The-Week Stickers Which Easily Identify Change Requirements. ; O Same Catheter Is Suitable To Be Used For Upto 72 Hours. ; O Sterile, Latex Free And Individually Packed. , Closed Wound Suction Unit O Close Wound Drainage Device Under Negative Pressure. ; O Provided With The Option To Use One Or Two Catheters Post-Operatively. ; O Connecting Tube Is Kink Resistant And Is Provided With Additional Strength To Withstand The Suction. ; O Multiperforated Catheters Provided With Radio Opaque Line And Satin Smooth ; Perforation/ Eyes For Trauma Free Performance. ; O Available In Different Sizes With Matching Size Curved Needle To Meet ; Moderate To Heavy Drainage Needs. ; O Graduated Bellow Allows User To Measure The Drainage Volume. ; O Flexible Bottle Chamber Is Easy To Be Depressed By One Person Single Handedly For Activating The Suction Of Bellow Unit. ; O Sterile, Individually Packed In A Box. Size: 10Fg/12Fg/14Fg/16Fg/18Fg , Combined Spinal Epidural Set , Compatible Part A With Bibag , Condom Catheter , Consumables For Aerogen Solo Ultrasonic Nebulisers , Consumables For Crrt And Bcm Machines,Make- Fresenius Medical , Consumables For Dvt Pumps And Enteral Feeding Pump - Make Cardinal Health , Consumables For Hotline Fluid Warmers , Continuous Neb Tube Set, Syringe & Cap Only (Pack Of 5) , Continuous Neb Tube Set, Syringe & Cap Only (Pack Of 50) , Continuous Neb Tube Set, Tubing Assembly Only (Pack Of 5) , Coplin Jar (Plastic) , Coplin Jar (Plastic) , Correguated Drainage Sheet Disposable , Coscos Speculum - Medium Size And Large Size , Craniotomy Drapematerial: 50 Gsm Sms Polypropylene Fabric Water Repellent . Sheet Size: 1.6 X 3.2M Adhesive Area 20Cm Dia.Side Channel & Collecting Funnel.Polysheet Lining 1.20 X 1.20M.Sterlized Pack. 5Years Expiry Life. Packing Material 45Gsm Polypropylene One Side And Another Side Tyvek Paper 25 Gsm. , Cresent Blade , Cryostat Blade-Low Profile, Made Of Stainless Steel With High Durability, Disposable Blades, 80 Mm Long X 8 Mm High X 0.25 Mm Thick Blades , Csf Flow Control Device , Cuff Controller , Cuff Pressure Gauge O It Should Be Designed To Monitor Air Pressure Of All Laryngeal Masks And Tracheal Tubeso It Should Have Integrated Inflation Bulb And Release Valveo The Diameter Of Dial Should Be At Least 68 Mm Or Moreo The Measurement Unit Should Be Graded In Cm H2oo The Measurement Zone Should Be With Colour Coding For Optimum Visibilityo It Should Have Standard Luer Connectiono The Equipment Should Be Latex-Freeo Standard Operating Temperature Should Be In Between +5 To + 40-Degree Celsiuso 100Cm Connecting Tube Should Be Provided With The Deviceo It Should Be European Ce Certified From Notified Body , Cuff Presure Gauzes , Custom Tubingpack , Cvp Line With Ecg Lead , Cvp Measuring Device O Suitable For Continuous Or Intermittent Monitoring Of Central Venous Pressure ; During Infusion, Particularly In Icu, Ccu, Ots And Casualty Departments. ; O Manometer Tube With Graduation From -4 Cm To +34 Cm And Attached To Three Way Tap. ; O Provided With 120 Cm Long Extension Tube, Fitted With Female Luer Lock On One End And Male Luer Lock On The Other End For Safe Connection To The Central Venous Catheter. ; O Latex Free Injection Site Is Provided For Extra Medication. ; O Sliding Indicator Provided To Record Previous Reading. ; O Moulded Clamps With Latex Free Rubber Strings For Easy Fixation On The Intravenous Stand. ; O Sterile, Individually Packed In Peelable Pouch. ; O Individually Packed In A Box. , Cvp Tranducer , Cvp Transducer With Pm Line And Iv Set: A. It Should Be Able To Give A Pressure & Waveform On Minimally Invasive Continuous Cardiac Out Put Monitor. B.It Should Be Able To Give A Pressure & Waveform On Any Multipara Monitor With Ibp Module. C.It Must Have 3±1 Ml/Hr Flow Rate Across Flush Device With Iv Bag Pressurized To 300 Mm Hg. D.It Must Have Moisture Resistance Connector Sheath Without Pin. E.It Should Have Gold/Copper/Aluminium- Plated Connector Wires. F.It Must Have An Operating Pressure Range Of -50 To 300Mmhg, With Overpressure Tolerance Range Of -500 To +5000Mm Hg. G. It Must Have A Provision To Put Arm Strap. H.It Should Have An Integrated Flush Device Which Can Be Operated From Any Direction For Easy Accessibility. I.It Should Have A Test Port That Can Be Used To Check The Performance Of The Transducer When Used Along With A Simulator Device For The Purpose. , Cytobrush , Dark Glasses , Disp. Wrap Spu Vest Medium , Disp. Wrap Spu Vest Small , Disposable Biopsy Gun Having Two Sample Notch 17Mm And 19Mm In The Same Device. ; Devicealso Has Two Depth Penetration Option 18Mm And 25Mm In A Same Device And Comes With Delay Firing Mode Option(Semiautomatic And Automatic Option) ; Sizes Are-14G,10Cm ,14G,16Cm ,16G,10Cm ,16G,16Cm 18G,10Cm ,18G,16Cm ,18G,25Cm ; Should Be Us Fda And Ce Approved. , Disposable Bougie (For Et Tubeintubating) , Disposable Bougie Vented (For Et Tubeintubating) , Disposable Bronchoscope O There Should Be No Optical Image Fibre Bundles In The Scope ; O It Should Have The Capability Of Easy Navigation And Fast Identification Of Anatomical Landmarks ; O The Scope Should Be Packaged Sterile To Eliminate The Risk Of Cross Contamination ; O It Should Be Integrated With One Cmos Camera And Two Led Light Source On Distal End ; O Minimum Length Of The Scope Should Be At Least 600Mm ; O The Working Channel Should Allow Fluid Instillation And Oxygen Flushing In Therapeutic Scope. ; O An Introducer Should Be Provided To Facilitate Introduction Of Endoscopic Accessories With Therapeutic Scope. ; O The Control Lever On Handle For The Movement Of Distal Tip Up & Down In A Single Plane ; O Should Have Intermittent Suction Controller To Control Suction Of Pressing. ; O It Should Be Us-Fda And European Ce Approved.Inner Diameter 1.2 Mm/ 2.2 Mm/ 2.8 Mm ; Outer Diameter 3.8 Mm/ 5.0 Mm/ 5.8 Mm ; Working Length 600 Mm; Bending Range 180Deg Up, 180Deg Down; Field Of View 85Deg ; Depth Of Field 6 - 50 Mm , Disposable Curved Circular Stapler 29 Mm-Row-3 , Disposable Curved Circular Stapler 32Mm-Row-3 , Disposable Cystoscope O There Should Be No Optical Image Fibre Bundles In The Scope ; O It Should Have The Capability Of Easy Navigation And Fast Identification Of Anatomical Landmarks ; O The Scope Should Be Packaged Sterile To Eliminate The Risk Of Cross Contamination ; O It Should Be Integrated With One Cmos Camera And Two Led Light Source On Distal End ; O Minimum Length Of The Scope Should Be At Least 390Mm ; O The Working Channel Should Allow Fluid Instillation. ; O An Introducer Should Be Provided To Facilitate Introduction Of Endoscopic Accessories With Therapeutic Scope. ; O The Control Lever On Handle For The Movement Of Distal Tip Up & Down In A Single Plane ; O It Should Be Us-Fda And European Ce Approved. ; Features Adult Scope ; Inner Diameter 6.6Fr ; Outer Diameter 16.2Fr ; Working Length 390 Mm ; Bending Range 210O Up, 120O Down ; Field Of View 120O ; Depth Of Field 3 -100 Mm , Disposable Endocapsular Rings , Disposable Iris Hook , Disposable Linear Cutter Reload 60-3.8 Blue,Cut Line 60Mm,Staple Line 64Mm , Disposable Linear Cutter Reload 60-4.8 Green,Cut Line 60Mm,Staple Line 64Mm , Disposable Linear Cutter Reload 80-3.8 Blue,Cut Line 80Mm,Staple Line 84Mm , Disposable Linear Cutter Reload 80-4.8 Green,Cut Line 80Mm,Staple Line 84Mm , Disposable Neonatal Spo2 Adhesive Sensor (20/Box) , Disposable Pace Maker Pad For External Pacing For Zoll Defillator , Disposable Perforator 11Mm/8Mm , Disposable Perforator 9Mm/6Mm , Disposable Perforator- Size 14Mm/11Mm , Disposable Rhinolaryngo Scopeo There Should Be No Optical Image Fibre Bundles In The Scope ; O It Should Have The Capability Of Easy Navigation And Fast Identification Of Anatomical Landmarks ; O The Scope Should Be Packaged Sterile To Eliminate The Risk Of Cross Contamination ; O It Should Be Integrated With One Cmos Camera And Two Led Light Source On Distal End ; O Minimum Length Of The Scope Should Be At Least 300Mm ; O The Working Channel Should Allow Fluid Instillation And Oxygen Flushing In Therapeutic Scope. ; O An Introducer Should Be Provided To Facilitate Introduction Of Endoscopic Accessories With Therapeutic Scope. ; O The Control Lever On Handle For The Movement Of Distal Tip Up & Down In A Single Plane ; O Should Have Intermittent Suction Controller To Control Suction Of Pressing With Therapeutic Scope ; O It Should Be Us-Fda And European Ce Approved. Inner Diameter 2.2 Mm ; Outer Diameter 5.0 Mm ; Working Length 350 Mm ; Bending Range 130O Up, 130O Down ; Field Of View 85O ; Depth Of Field 6 - 50 Mm ; Direction Of View Oo (Forward View) ; Illumination Method Led , Disposable Scalpel-Different Size , Disposable Shear 36Mm For Ultrasonic Generator , Disposable Shoe Cover- 45 Micron Thick Wate Proof,Length Cover Upto Knee, Note:- Product Should Be In Sterilized Pack.Packet Material 35 Gsm Polypropylene One Side And Another Side Tyvek Paper 35 Gsm Packing. , Disposable Skin Grafting Blades , Disposable Vaginal Speculum O Disposable Vaginal Speculum. ; O Speculum Is Used To Widen The Opening Of Vagina For Providing Clear Visibility Of The Cervix. ; O Made Of Clear, High Strength, Non-Toxic Polymer. ; O Designed To Eliminate The Time And Expense Of Reprocessing Metal Specula. ; O Single Use Speculum Also Minimizes The Risk Of Cross-Contamination ; Associated With Improper Cleaning And Sterilization. ; O Smooth And Ergonomically Designed For Comfort. ; O Built-In Led Illumination Light Source For Proper Examination. ; O Locking Facility Enables Necessary Vaginal Widening Adjustments. ; O Facilitates Self-Holding In A Variety Of Positions. ; O Allows Single-Handed Operation. ; O Sterile And Individually Packed. , Disposables And Modules For Cardiac Monitor, Make- Edwards , Disposables For Portable Deployable Isolation System With Negative Flow Make- Bed Air , Double Lumen Femoral Catheter Curved , Double Lumen Femoral Catheter St. , Double Lumen Laryngeal Mask Airwayo Specialised Mask To Enable An Effective Oro-Pharyngeal Seal Accompanied By The Oeso-Phageal Seal At The Oeso-Phageal Sphincter. ; O 100% Silicone Mask Enables Smooth Intubation And Extubation And Also Offers Enhanced User Safety. ; O Uniquely Designed Device With Special Port To Provide Tracheal Ventilation Along With Gastric Access. ; O Shaped As Per Anatomical Structure To Facilitate Successful Intubation. ; O Primary Seal Enables Independent Ventilation And The Secondary Seal Offers Improved Safety And Encourages Drainage Of Digestive Tract Contents Independent Of Ventilation. ; O Diminishes The Chances Of Aspiration. ; O Ventilation Tube Clearly Marked With All Information Like Mask Size, Patients Weight And Cuff Inflation Volume. ; O Single Use, Sterile Device. , Double Lumen Tube O Robertshaw Tube Designed To Fit Patients Anatomy For Thoracic Or Pulmonary Surgery And Single Lung Long-Term Ventilation. ; O Anatomically-Correct Curvatures Facilitate Proper Placement And Intubation. ; O High Volume/ Low Pressure Tracheal Cuff Has A True Barrel Shape That Minimizes Pressure On The Tracheal Tissue And A Uniquely Shaped Bronchial Cuff Helps Prevent Accidental Upper Lobe Occlusion. ; O Tracheal Cuff Separates The Lung From The Environment. ; O Bronchial Cuff Separates The Lungs From Each Other. ; O Colour-Coded Pilot Balloons With Luer-Lock Connector, Marked With The Name Of The Lumen (Tracheal Or Bronchial) For Easy Identification. ; O D Shaped Lumina Provide Maximum Cross Sectional Area, Minimising Resistance To Gas Flows. ; O Provided With Double Swivel Connections With Double Caps. ; O Sterile, Individually Packed. , Dry View Flims For Mri Size 14 17 , Durepore , Dviu Knife , Ear Rubber Bulb , Ecg Electrodeneonatal With Wire O It Should Be Design With Silver/Silver Chloridesensor And Highly Conductive Solid Gel Ensures Clear Recordings For A Precise Diagnosis. ; O It Should Have Hydrophobic Adhesive. ; O Lead Wires Should Be Radiolucent, So There Is No Need To Either Remove The Electrodes Or Touch The Neonate ; O During X-Ray Procedures. ; O It Should Be Ce/Iso,Us Fda Certified , Ecg Electrode Blue Sensor Neonatal O It Should Be Design With Offset Connector And Wet Gel Ensures Clear Recordings For A Precise Diagnosis. ; O It Should Be Oval Shape Design With Silver/Silver Chloride Sensor. ; O It Should Be Ce/Iso,Us Fda Certified , Ecg Paper At-102 G2 , Ecg Paper For 12 Channel E.C.G Machine, Model:Cardiomin 12B , Echo Jelly , Edward Oxymeter Central Venous Catheter , Endotracheal Tube Cuffed Thermo-Sensitive Tube Conforms To The Tract Anatomy. ; O Conforms To F-29 Standards. ; O Kink Resistant Tube Ensures Patient Safety. ; O Strong Tube Walls To Ensure Proper Ventilation. ; O Murphy Eye Has A Polished Smoothness Ensuring Atraumatic Intubation And Extubation. ; O Features A High-Volume, Low Pressure Cuff. ; O Soft Cuff Allows Air Tight Fit Between The Tube And Trachea. ; O Wide Black Ring Above Cuff Gives Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. ; O Radio-Opaque Line Determines Exact Location. ; O Standard 15Mm Connector. ; O Sterile Individually Packed In Peelable Blister Pack. , Endotracheal Tube Plaino Manufactured From Thermo-Sensitive Material Readily Conforming To Body Contours At Body Temperature. ; O Kink Resistant And Transparent Material To Reduce Any Possibility Of Occlusion In The Tube Bore. ; O Nasoral Tip Suitable For Nasal/ Oral Intubation. ; O Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma To The Patient During Procedure. ; O Provided With Radio-Opaque Line Throughout The Length For X-Ray Detection And Assistance In Placement. ; O Proximal End Is Fitted With Standard 15 Mm Connector Which Can Snugly Fit With Other Commonly Used Connectors. ; O Sterile Individually Packed In Peelable Blister Pack. , Endotracheal Tube With Subglotic Suction - Different Size , Ent Adult - Airway Balloon Catheter-10Mm*40Mm/12Mm*40Mm/14Mm*40Mm/16Mm*40Mm , Ent Pediatric - Airway Balloon Catheter-5Mm*24Mm/7Mm*24Mm/9Mm*24Mm , Ent-Balloon Inflation Device , Epidural Kit , Epidural Anesthesia Kito Epidural/Tuohy Needle : Tuohy Type Needle Is Provided With Clear Depth Marking For Accurate Insertion And Depth Reading With Polished Inner Bevel Edge To Minimize The Risk Of Catheter Shearing. ; O Epidural Catheter : Closed Round Soft Tip With Three Lateral Eyes. ; O Lor Syringe : Specially Designed Syringe Suitable For Air And Saline Technique, Provides Clear Identification Of Epidural Space. ; O Threading Assist Guide : Fits Securely Into The ; Needle & Assists In Easy Advancement Of Catheter. ; O Detachable Connector : Separate Twist Lock ; Connector. ; O Hydrophillic Filter : Hydrophillic 0.2 Micron Filter Provides Additional Safety & Control Against Microbial Infections. ; O Sterile, Individually Packed In A Box. , Epidural Catheter O Soft Tip Epidural Catheter Is Specially Designed For Continuous Anaesthesia And Pain Relief Therapy. ; O Catheter Is Made From Unique Plasticizer Free Polymer With Excellent Bio-Compatibility. ; O Flexible And Atraumatic Soft Tip With Three Lateral Eyes. ; O Catheter Is Printed To Determine The Depth Of Insertion And Accurate Placement In The Epidural Space. ; O Luer Lock Twist Connector. ; O Crystal Clear Catheter With Radio Opaque Line. ; O Sterile, Individually Packed In Peelable Pack. , Epidural Catheter Size 22G , Epidural Needle 20G , Esmarch Bandage 3 , Esmarch Bandage 4 , Esmarch Bandage 5 , Et Tube Extension ( For Ventilator) , Ett Intubating Stylet (Small, Medium, Large) , Eusachian Balloon Catheter- It Should Have A Non Complaint Balloon With Puncture Resistance. It Should Have A Working Length Of 256Mm. It Should Have A Flexible Shaft. .It Should Have Marker Bands For Endoscopic & Direct Visualization. It Should Have Separate Port For Inflation / Deflation And A Separate Port For Introduction Of The Guide Wire. Balloon Should Reach Its Stated Size At 6Mm * 17Mm Atmosphere And Should Withstand 10 Atmospheric Pressure. , Eustachian Balloon Catheter- It Should Have A Non Complaint Balloon With Puncture Resistance. It Should Have A Working Length Of 256Mm. It Should Have A Flexible Shaft. .It Should Have Marker Bands For Endoscopic & Direct Visualization. It Should Have Separate Port For Inflation / Deflation And A Separate Port For Introduction Of The Guide Wire. Balloon Should Reach Its Stated Size At 6Mm * 14Mm Atmosphere And Should Withstand 10 Atmospheric Pressure. , Eustachian Balloon Inflation Device -It Should Have A Ergonomic Piston Handle For Safe And Controlled Inflation/Deflation Of The Balloon Catheter. It Should Have Clear Grading Of Different Pressure Levels. It Should Have High Pressure Connector Tubing To Connect To The Balloon Catheter. It Should Be Compatible With Different Sinus Balloon Catheters. It Should Have Clear High Pressure Cylinder Barrel To Indicate The Level Of Saline/ Fluid Inside The Inflation Device. It Should Have A Piston Locking System To Prevent Accidentalinflation/Deflation Of The Balloon Catheter , Eustachian Guide Catheter- It Should Have A Non-Malleable Stainless Stell Shaft. It Should Have Clear Distal Portion For Endoscopic Visualizationof Tuboplasty Instrumentation And A Coloured Atraumatic Tio For Endoscopic Visualization.It Should Consist Of A Scetion Barb And Hub For Clearing Thin Secretions. It Should Be Compatible With Guide Handle To Enable Single Handed Operation Of The Scope And Tuboplasty Kit.It Should Becompact In Size To Acess The Eustachian Tube Cannel.Guide Catheter Should Be Approved By Credible Authorities For Futher Safety Of Patients. Authority Like Cdsco Of India. , Eustachian Guide Handle- It Should Be Compatible With Guide Catheter. It Should Be Malleable To Suit Different Users. It Should Have A Hand Tight Grip Surface For Better Control And Stability.It Should Have A Lumen To Introduce Ballooninstrumentation , Express Cable (Connecting Cable Between Icp Monitor & Microsensor Icp Transsducer) , External Lumber(Csf) Drainage System With Double Chamber Bag. , External Ventribular Drainage System With Double Chamber Bag , Eye Drapematerial : 25Gsm Sms Polypropylene Febric Water Repellent Blue Colour. Sheet Size. 90X70cm Incise Area. 7X9cmeye Lid Holder. 6 Pcs. Drainage Pouch Of Transparent Film 1Nos. Eto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life. , Facial Oxygen Tent Mask Adult/Ped , Fast Absorbing Polyglactin 910 Undyed 140 Cm,1/2 Circle Round Body 1/2 Circle Reverse Cutting Double Needle,Needle-36 Mm,Size-2-0,Box Of-12 Foils , Fast Absorbing Polyglactin 910 Undyed Braided 45 Cm,3/8 Circle Cutting,Needle-16 Mm,Size-3-0,Box Of-12 Foils , Fast Absorbing Polyglactin 910 Undyed Braided 70 Cm,1/2 Circle Round Body,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Fast Absorbing Polyglactin 910 Undyed Braided 70 Cm,3/8 Curved Reverse Cutting,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Fast Absorbing Polyglactin 910 Undyed Braided 75 Cm,3/8 Circle Cutting Pc 3 Ethiprime,Needle-16 Mm,Size-3-0,Box Of-12 Foil , Fast Absorbing Polyglactin 910 Undyed Braided 75 Cm,3/8 Circle Reverse Cutting Prime Ps,Needle-26 Mm,Size-3-0,Box Of-12 Foil , Fast Absorbing Polyglactin 910 Undyed Braided 90 Cm,1/2 Circle Tapercut V-34,Needle-36 Mm,Size-2-0,Box Of-12 Foil , Fast Absorbing Polyglactin 910 Undyed Braided 90 Cm,1/2 Circle Tapercut,Needle-35 Mm,Size-2-0,Box Of-12 Foils , Feeding Bago Feeding Bag Is An Enteral Feeding Bag Intended For Gastro-Intestinal Feeding. ; O Specially Designed 1.2 Litre Capacity Bag Made Up Of Dehp Free Pvc. ; O An Ice Pouch Is Provided On The Rear Side Of The Bag For Preserving The Food For Longer Intervals Of Time. ; O A Dehp Free Transfer Set Is Directly Connected To The Bag. ; O Roller Controller Provided On The Transfer Set Facilitates Control On The Administered Feed. ; O The Feeding Bag Is Graduated To Determine Precisely The Quantity Of The ; Administered Feed. ; O Feeding Bag Is Provided With A Closure Cap And Also A Hanger For Safe Hanging During And After Use. ; O Sterile, Individually Packed In Peelable Pouch. , Femoral Catheter 16G , Fenestrated Tracheostomy Tube Diff Size , Filliform Urethral Dialators , Filter Cartridge 20 20?M Big Blue Cat No. 6349711 , Filter Pod , Filters Pod For Bed Air , Filtrate Bag 10L , Fistula Imported , Fistula Needle , Five Layered Highly Absorbent Foam Dressingwith Self Adherent Borders Soft-Silicone Safetec Wound Contact Layer For Painles Dressing And Wound Pad Comes With Flex Cut Techonology For 360 Degree Flexibility Of Dressing . Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 7.5X7.5 Cm , Five Layered Highly Absorbent Foam Dressingwith Self Adherent Borders Soft-Silicone Safetec Wound Contact Layer For Painles Dressing And Wound Pad Comes With Flex Cut Techonology For 360 Degree Flexibility Of Dressing . Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 12.5X12.5 Cm , Five Layered Highly Absorbent Foam Dressingwith Self Adherent Borders Soft-Silicone Safetec Wound Contact Layer For Painles Dressing And Wound Pad Comes With Flex Cut Techonology For 360 Degree Flexibility Of Dressing . Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 15X15 Cm , Five Layered Highly Absorbent Foam Dressingwith Self Adherent Borders Soft-Silicone Safetec Wound Contact Layer For Painles Dressing And Wound Pad Comes With Flex Cut Techonology For 360 Degree Flexibility Of Dressing . Product Should Be Usfda/Ce Certified. Usage- Upto 7 Days. Size- 17.5X17.5 Cm , Five Layered Highly Absorbent Foam Dressingwith Self Adherent Borders Soft-Silicone Safetec Wound Contact Layer For Painles Dressing And Wound Pad Comes With Flex Cut Techonology For 360 Degree Flexibility Of Dressing . Product Should Be Usfda/Ce Certified.Usage- Upto 7 Days. Size- 15X20 Cm , Five Layered Self- Adhesive Absorbent Heel Dressing Designed For Exuding Wounds, With Soft Silicone Adhesivesafetecwound Contact Layer, With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Acquisition Layer Made Up Of Polyurethane Foam & Spreading Layer Made Up Of Non-Woven Viscose Polyester, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 22X23 Cm , Five Layered Self- Adhesive Absorbent Sacral Dressing Designed For Exuding Wounds, With Soft Silicone Adhesive Safetec Wound Contact Layer, With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Acquisition Layer Made Up Of Polyurethane Foam & Spreading Layer Made Up Of Non-Woven Viscose Polyester, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 22X25 Cm , Five Layered Self- Adhesive Absorbent Sacral Dressing Designed For Exuding Wounds, With Soft Silicone Safetacwound Contact Layer, With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Acquisition Layer Made Up Of Polyurethane Foam & Spreading Layer Made Up Of Non-Woven Viscose Polyester, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 16X20 Cm , Flexometalic Armoured Tracheal Tube With Cuff Size -5 , Flexometalic Armoured Tracheal Tube With Cuff Size -5.5 , Flexometalic Tubesize -5Mm To 9Mm , Flexometalic Armoured Tracheal Tube With Cuff Size -6.5 , Flexometalic Armoured Tracheal Tube With Cuff Size -7 , Flexometalic Armoured Tracheal Tube With Cuff Size -7.5 , Flexometalic Armoured Tracheal Tube With Cuff Size -8 , Flexometalic Armoured Tracheal Tube With Cuff Size -8.5 , Flexo-Metallic Endotracheal Tubeo Flexo-Metallic Endotracheal Tube For Airway Management Intended For Use In Surgeries Demanding Flexible Head Or Neck Position. ; O Specially Designed Suitable To Laryngeo-Tracheal Anatomy. ; O Tubes Are Fitted With A Reinforced Stainless Steel Spiral Core To Overcome Any Possibility Of The Bore Occlusion Due To Kinking Or Collapse Of The Tube. ; O Flexo-Metallic Feature Provides 100% Kink Resistance And Anti-Crushing Strength To The Endotracheal Tube. ; O Completely Flexible Tube With A Thin, Strong Wall. ; O High Volume, Low Pressure Cuff Provides Effective Seal Between Tube And Trachea And Minimizes The Risk Of Folds. ; O Radio Opaque Line With Precise Graduation Marking Guarantees Proper Placement Of The Tube. ; O Murphy Eye Ensures Clear Airway And No Mucus Blockage. ; O Conforms To F-29 Standards. ; O Sterile, Individually Packed. , Flexometallic Supraglottic Airway O The Airway Tube Should Be Wire-Reinforced To Eliminate The Risk Of Occlusiono It Should Be Specially Designed For Ent, Ophthalmic, Dental And Other Head And Neck Surgerieso The Pilot Balloontube Should Be Integrated With Airway Tube, Eliminating Risk Of Accidental Cutting During Surgerieso It Should Have Reinforced Tip At Cuff To Avoid Kinking During Insertiono Cuff And Airway Tube Should Be Moulded As A Single Unit For Safety - No Separationo It Should Have Depth Marks For Monitoring Correct Positioning Of The Masko It Should Provide Maximum Intra-Cuff Pressure Of Up To 60 Cmh20o It Should Have 15 Mm Male (Iso) Airway Connectoro It Should Be Disposable, Eliminating Chances Of Cross Contaminationo It Should Be Made Of 100% Phthalate-Free And Latex-Free Medical Graded Materialo Should Be Available In All Standard Sizes To Accommodate Paediatric & Adult Patientso Should Be Us Fda, Ce & Iso Certified For Quality Assurance , Flotrac Cardiac Output Sensor For Hemo Sphere Monitor , Flow Trac , Flow Trach Catheter For Measuring Cardiac Output , Flower Tip Suction Cathetero Endo-Bronchial Suction Catheter With Patented Non-Traumatic Flower Tip. ; O Manufactured From Non-Toxic And Non-Irritant Medical Grade Pvc. ; O Provided With Unique Integrated Ring Type, Open End Flower-Shaped Tip To ; Minimize Any Mucosal Damage During The Suction Procedure. ; O Specially Designed Oro-Bronchial Catheter Is Automatically Centered During Suctioning Due To Its Integral Ring Type Design. ; O Smooth Tip Prevents Irritation To Tracheal Mucosa And Adds To Patient Comfort. ; O Provided With Two Round Lateral Eyes At The Distal End Which Enables Uniform Pressure Distribution And Facilitate Efficient And Uninterrupted Suctioningeven If The Main Tip Gets Occluded. ; O Sterile, Individually Packed In A Peel Open Soft Blister Pack. ; O Size: 6,8,10,12,14,16 Fg , Fnac Franzen Handle , Foldable Lens No.19 , Foldable Lens No.20 , Foldable Lens No.21 , Foldable Lens No.22 , Foldable Lens No.23 , Foldable Lens No.24 , Foldable Lens No.25 , Foldable Lens No.26 , Foldable Lens Of Differente Power +17D To +26D , Foleys Cathetero Foley Catheter Used For Short Or Long Term Urine Drainage. ; O Made Up Of Latex Bonded With Silicone Elastomer Which Eliminates The Risk Of Encrustation. ; O Smooth Surface Facilitates Non-Traumatic Intubation. ; O Distal End Is Coned And Provided With Super Smooth, Burr Free Eyes For Atraumatic Intubation. ; O Provided With Symmetrical Large Capacity Balloon That Ensures Straight Tip For ; Proper Urine Flow And Good Sphincter Action, Preventing Bladder Leakage. ; O Hard Non-Return Valve Ensures Trouble Free Inflation And Deflation Of Balloon. ; O Valve Is Colour Coded For Instant Size Identification. ; O Sterile, Ready For Use. Size: 12Fg To 24Fg , Fougarte Catheter , Full Gown Material : 60 Gsm Nw Sms Spun Lace Wrap Around Full Gown. Length 120Cm. 2Nos Hand Towel. Sterlized With 5Years Expiry Life. 45 Gsm Polypropylene Material One Side And Another Side 25 Gsm Tyvek Paper. , H.F Filter , Half Gown Material : 25 Micron Thick Pe Hygiene Film . Size :110Cm Length Half Gown Waterproofeto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life. , Handpiece Set With Coaxial High Flow Tip And Suction Tube , Hard Cervical Collar , Hemorrhoids Stapler-34Mm-Row-3 , Hewoeon Ceutralize , Hf Female Spike Adapter , High Concentration Oxygen Mask O Specially Designed For High Concentration Oxygen Therapy. ; O Soft, Transparent And Odor Free Vinyl Mask For Greater Patient Comfort. ; O The Smooth, Feathered Edges Are Designed For Patient Comfort While Reducing Irritation Points. ; O The Mask Fits Snugly Over The Patients Mouth And Nose. ; O Adjustable Elastic Strap Fits Over The Patients Head Holding The Mask In Place. ; O The Mask Also Has A Reservoir Bag That Is Inflated With Pure Oxygen. ; O The Reservoir Bag Allows For Adequate Oxygen To Be Available To Meet The Unpredicted Patients Breathing Pattern And Tidal Volume. ; O Non-Return Valves Provided At Inhale And Exhale Points Prevent Carbon-Dioxide Retention. ; O Light Weight Reservoir Improves The Oxygen Efficiency. ; O Non-Sterile, Individually Packed. ; Unit Consists Of : ; O Mask With Elastic Strap ; O Mask Connector With Non-Return Valve ; O 600 Ml Reservoir Bag ; O 200 Cm Long Multichannel Tube , High Flow Circuit-F&P(Air Vo2)900Pt561, Heated Humdifire Chamber Kit , High Pressure Monitoring Line O Dehp Free Polyethylene High Pressure Monitoring Extension Line. ; O Non-Reactive And Highly Compatible To All The Commonly Infused Fluids. ; O Small Bore High Pressure Extension Line Suitable For High Pressure Applications, For Example As Connection Between Syringe, Infusion Pump And The Patient. ; O Provided With Male And Female Luer Lock At Either Ends, ; Which Facilitates Secure Fitting To All Standard Equipment. ; O Luer Lock Connectors Provide Secure Fitting. ; O Can Sustain A Pressure Upto 40 Kg/ Cm² Or 560 Psi. ; O Sterile, Individually Packed In Blister Pack. , Highly Compressed Silicone Dressings For Scars, With Shower Proof Backing Film Made Up Of Polyurethane Film, With Textile Core Made Up Of Non-Woven Polyester, With Ultra Violet Protection Factor 5. A Protective Release Liner Made Up Of Polypropylene Film. Self Adherent Soft Silicone Adhesive Technology. Size- 5X7.5 Cm Ce And Usfda Certified , Highly Compressed Silicone Dressings For Scars, With Shower Proof Backing Film Made Up Of Polyurethane Film, With Textile Core Made Up Of Non-Woven Polyester, With Ultra Violet Protection Factor 5. A Protective Release Liner Made Up Of Polypropylene Film. Self Adherent Soft Silicone Adhesive Technology. Size- 10X18 Cm Ce And Usfda Certified , Highly Compressed Silicone Dressings For Scars, With Shower Proof Backing Film Made Up Of Polyurethane Film, With Textile Core Made Up Of Non-Woven Polyester, With Ultra Violet Protection Factor 5. A Protective Release Liner Made Up Of Polypropylene Film. Self Adherent Soft Silicone Adhesive Technology. Size- 4X30 Cm Ce And Usfda Certified , Hiv Protection Kit1. Wrap Around Full Gown 55Gsm Sms Material, Water Repellent, 120Cm Length. 1Nos. 2. 25 Micron Polyproplene Plain Sheet 1.2 X 2.1M Length. 2Nos. 3. 1Nos 1Pair Water Proof Leggings. 4.1Nos Non Woven Cap.5.1Nos 3Ply Surgical Mask.6. 1 Nos Disposable Bag. Sterlized Pack.Packing Material 45Gsm Polypropylene One Side And Another Side Tyvek 25Gsm Paper Packing. 5Years Expiry Life. , Hme Fillterh.M.Es Are Passive Humidification Systems That Retain Heat And Moisture ; From The Patients Exhaled Gas. ; O Provides Effective Protection Against Various Types Of Particles Including ; Bacteria, Viruses, And Moisture Droplets. ; O Precisely Engineered And Easy To Use Device Made Up Of High Strength Plastic Material Offering Reliable Performance. ; O Provided With High Efficiency Electrostatic Filters To Address Concerns Associated With Ventilated Patients. ; O The Filters Help Protect The Patient, The Equipment, And The Breathing Circuit From Contamination. ; O Enhances Particle Capture Efficiency And Give A Low And Stable Breathing Resistance Even When Wet. ; O A Conveniently Located Port Or Connection Permits Gas Sampling At The Top Of The Housing, ; O H.M.E.Fs Are Designed According To Iso Standards To Help Facilitate Connection To Different Ventilators And Anesthesia Systems. ; O Sterile, Single Use Device, Individually Packed. , Hme Filter With Encloser , Hme Membrane , Hme Membrane , Hormonal Intra-Uterine System With Applier , Hotline Warming Set-Disp 30/Ca, L 70 , Hub Cuttersafety Portable Box For Disposal Of Hypodermic Needles.; O For Single, One -Time Use To Prevent Risk Of Needle Stick Injuries To Hcw Handling Sharps ; O No Electricity Required; O Ability To Cut The Needle From The Hub Of Syringe ; O Container With Yellow Casing And Cap Of Volume 0.3Lts Where, Exterior Can Be Cleaned With 70% Alcohol.; O Puncture Resistant Hard And Can Be Locked , Hub Cutter With 100 Hypodermic Needle Collection Capacity, Made Of Polypropylene (Pvc Free Plastic), Autoclavable For Final Disposal, Slide Door For Temporary Closure While Usage , Portable To Dispose Needle At Bedside, No Heavy Metals Used For Construction, Translucent Container For Visualization Of Fill Level , Label With Biohazard Symbol, Meeting All Requirements Of Bio Medical Waste Management Rule- Sharp Disposal, Non-Burn Technology Device , Hydrocolloid Dressing, Size- 10.5 X 12 , Hydrocolloid Dressing, Size- 10.5 X 17 , Hydrogen Peroxide Gas Cassette , Hydrophilic Acrylic Foldable Lens Optic Diameter -6.00Mm,; Overall Length-12.50Mm ; A Constant -118.00 , Hydrophilic Acrylic Foldable Lens Optic Diameter -6.00Mm,; Overall Length-12.50Mm ; A Constant -118.00 ; Fully Aspheric Optics With 360 Degree Square Edge , Hydrophobic Acrylic Foldable Lens Dimeter 6.00Mm,Overall Length-13.00Mm, A Constant -118.80 , Hydrophobic Acrylic Foldable Lens Dimeter 6.00Mm,Overall Length-13.00Mm, A Constant -118.80 , Hydrophobic Foldable Acrylic Lens Semi Preloaded ,Natural Yellowchromophore,360 Deg Square Edge- Fully Aspheric Opticsdiameter -6.00Mm, Overall Length-13.00Mm ;A Constant -118.8 , Hydrophobic Foldable Acrylic Lens With Preloaded Injecting Systemdiameter -6.00Mm, Overall Length-13.00Mma Constant -118.8Fully Aspheric Optics With , Hydrophobic Foldable Single Piece Intraocular Lens , Hydroxypropyl Methyl Cellulose Opthalmic Solution Usp 2.0%Appavisc3ml , Hydroxypropyl Methyl Cellulose Opthalmic Solution Usp 2.0%Appavisc5ml , I V Cannula Vialon Made Venous Access Device For Prevention Of Needle Stick Injuries And Safety From Unanticipated Blood Exposure (Or Splatter), The Needle Tip Should Be Totally Encapsulated In A Plastic Shield. Sizes : 14G, 16G, 18G, 20G & 22G. , I V Cannula-Adultported Intravenous Cannula Having Back Cut Needle Bevel & Ptfe Catheter With Tapered End With Noise Needle And Intra Flush Technology ; Sizes : 14G, 16G, 18G, 20G & 22G. , I V Cannula-Pediatric Non-Ported Virgin Ptfe Cannula With Flexible Wings, Made Of Polypropylene, Vailon, Stainless Still304, Polydimethylsilosne, Hdpf,Ldpe. ; Sizes: 24G, 26G , I V Set O Safety Infusion Set, Dehp Free. ; O Vented Spike Fits Tightly, Ensuring Easy Insertion And Removal. ; O Comes With Unique Air Stop Feature Which Is A Hydrophilic Filter Membrane Present At The Bottom Of The Drip Chamber Which Prevents The Ingress Of Air In Case Of Emptied Fluid Container. ; O Provided With An Innovative Prime Stop, Which Is A Hydrophobic Membrane ; Placed On The Luer Lock Fitting That Stops Fluid Leaking And Dripping On The Floor. ; O Longer Drip Chamber Fits Firmly In The Users Hands, Ensuring A Better Grip. ; O Specially Designed Y Type Injection Port Made Up Of Silicone Having Re-Sealing Property Is Provided For Additional Medication. ; O Soft, See-Through, Clear 180 Cm Long Dehp Free Pvc Tubing, Which Is Kink Resistant For Uninterrupted And Smooth Flow. ; O Advance, Handy Roller Clamp For Efficient Control. ; O Sterile And Individually Blister Packed. , I.B.P Electrodes (Disposable) , I.V. Cannula With Three Way Stop Cock , I.V. Extension Line 150 Cc , I.V. Fexater Transparent , Icd Chest Tube Set With Trocar Size-16,18,20,22,24 , I-Gel Laryngeal Mask All Size1 To 6 , Implant Blade , Incentive Spirometer , Infant Feedingtube O Infant Feeding Tube With Graduation. ; O Made From Dehp Free, Non-Toxic Pvc Material Completely Non-Irritant To Delicate Mucosa. ; O The Tube Features Low Friction, Super Smooth Frozen Surface Ensuring ; Non-Traumatic Intubation. ; O The Tube Is Marked At Every Cm Starting From Tip At 5Cm To 40Cm To Enable Accurate Placement. ; O Distal End Of The Tube Is Coned For Smooth Intubation And Equipped With Two ; Lateral Eyes For Efficient Drainage And Administration. ; O Proximal End Is Provided With Female Luer Mount For Easy Connection To Feeding Funnel Or Syringe. ; O Radio-Opaque Line Facilitates Accurate Tube Placement. ; O Color Coded For Immediate Size Identification. ; O Sterile, Straight Packed In Peelable Soft Blister Pack. ; Size: 5Fg To 10Fg , Infusion Pipe Pump , Insuline Syringedisposable Single Use Insulin Syringe With Integrated Needle Made Of Polypropylene Plastic With Tbl Technology . Should Have No Dead Space Design & Tribevel Needle Tip. ; Strength: U40 & U100 With 31G Needle. , Integrated Closed Iv Catheter System With Pre-Attached High Pressure Extension Set (Upto 300 Psi) With Two Split Septum Needle Less Connector, Needle Tip Fully Encapsulated In Plastic Cap For Nsi Prevention, Size- 18G/20G/22G/24G , Integrated Closed Iv Catheter System:Integrated Closed Iv Catheter System With Pre-Attached High-Pressure Extension Set (Up To 300 Psi) With Two Split Septum Needle Less Connector, Needle Tip Fully Encapsulated In Plastic Cap For Nsi Prevention. Available Sizes: 18G, 20G, 22G, 24G.Pack Sizes: 20 Pcs Box. , Intercostal Drainage Tube , Intra Cardiac Sump , Intubating Supraglottic Airway O It Should Be Anatomically Curvedfor Fast And Easy Insertion ; O It Should Have Intubation Capability Using Standard Et-Tubes ; O It Should Allow Placement Of Maximum 8.0 Et Tube Through The Airway ; O Cuff And Airway Tube Should Be Moulded As A Single Unit For Safety - No Separation ; O The Cuff Should Have Reinforced Tip To Avoid Kinking During Insertion ; O Should Have Integrated Bite Resistance To Prevent Airway Occlusion ; O It Should Have Depth Marks For Monitoring Correct Positioning Of The Mask ; O The Pilot Balloon Should Provide Mask Size & Tactile Indication Of Degree Of Inflation ; O It Should Have Navigation Marks For Guiding Flexible Scope During Intubation ; O It Should Provide Maximum Intra-Cuff Pressure Of Up To 60 Cmh20 ; O It Should Have 15 Mm Male (Iso) Airway Connector ; O It Should Be Made Of 100% Dehp-Free Medical Graded Material ; O It Should Be Disposable, Eliminating Chances Of Cross Contamination ; O It Should Be Mr Safe ; O Should Be Available In All Standard Sizes To Accommodate Any Age Group Of Patients ; O Should Be Us Fda, Ce & Iso Certified For Quality Assurance , Intubation Pressure Bag , Io Drape Extra Large Size: 90X45cm Adhesive Area : 60X45cm. For Covering Incision Area In All Kindof Surgeries Povidine Iodine 5% Adhesive Coated (45 Gsm Approx)Pu Film. Eto Strlized . 5Years Expiry Self Life. , Io Drape Large Size: 50X35cm Adhesive Area 35X35cm. For Covering Incision Area In All Kindof Surgeries Povidine Iodine 5% Adhesive Coated (45 Gsm Approx)Pu Film. Eto Strlized . 5Years Expiry Self Life. , Io Drape Medium Size: 50X25cm Adhesive Area : 30X25cm. For Covering Incision Area In All Kindof Surgeries Povidine Iodine 5% Adhesive Coated (45 Gsm Approx)Pu Film. Eto Strlized . 5Years Expiry Self Life. , Io Drape Small Size 15X10cm Adhesive Area : 10X10cm. For Covering Incision Area In All Kindof Surgeries Povidine Iodine 5% Adhesive Coated (45 Gsm Approx)Pu Film. Eto Strlized . 5Years Expiry Self Life. , Iodine Adhesive Drape Size 15X20) Adhesive 10X20 , Iodine Adhesive Drape Size 25X50) Adhesive 30X25 , Iodine Adhesive Drape Size 35X60) Adhesive 35X35 , Iodine Adhesive Drape Size 90 X 45) Adhesive 60X45 , Iodine Adhesive Drape Size 90 X 45) Adhesive 60X45 , Iv Extension Line 100Cm Doule Lumen , Iv Extension Line 100Cm Tripal Lumen , Iv Extension Line 10Cm Doule Lumen , Iv Extension Line 10Cm Tripal Lumen , Iv Infusion Kit I.V Infusion Kit. ; O Convenient Kit For Quick And Easy Administration Of Intravenous Infusion To A Patient In An Emergency Setting. ; O Kit Contains All The Items Needed To Facilitate Intravenous Delivery. ; O Each Item Is Individually Wrapped, Conveniently Assembled And Packed. ; O Sterile, Individually Packed In A Peel Open Pack. ;; Kit Consists Of : ; O Infusion Set : Standard Non-Vented ; O I.V Cannula : 18, 20, 22 G ; O I.V. Cannula Fixator : 5 X 6 Cm ; O Syringe With Needle : 5 Ml (24 Ng X 1) ; O Alcohol Swab : 45 X 50 Mm ; O Cannula Site Protection Tab : Standard , Jelonet (Paraffom Impregrated Dressing Material , Kehrs T Tube Different Size , Keratome Bevel Down 2.8Mm , Keratome Bevel Down 5.2Mm , Keratome Blade , Knee Drape Material : 50 Gsm Sms Polypropylene Water Repellent.Overall Size240x340cmelastic Aperture. 5Cm Dia. Polysheet Lining. 120X120. Funnel.Polysheet Lining 1.20 X 1.20M.Sterlized Pack. 5Years Expiry Life. Packing Material 45Gsm Polypropylene One Side And Another Side Tyvek Paper 25 Gsm. , L Block - Brass Made , L.P Needle 18, 20 , Lament Needle , Laminospinal Drape Material : 50 Gsmpolypropylene Water Repellent Febric .Sheet Size : 1.5 X 3Mincise Sheet 15 X 35Cm Poly Sheet Lining 1.20 X 1.20Cmpacking Material: 45 Gsm Polypropylene One Side Another Side 25Gsm Tyvek Paper. Strlized Packed With 5 Years Expiry Life. , Laparoscopic Powered Endocutter Stapler 60Mm Medium.Mec60-340 , Laparoscopy Pack- Waterproof Transparent File Dressing With Non Adherant Absorbent Pad., Transparent P.U Films With Hypoallergic Adhesive, Non Woven Absorbent Pad Pkt Of 4 Dressings. Silicon Paper Release Liner , Laproscopic Applicator For 300 Clips , Laproscopic Applicator For 400 Clips , Laryngealmask With Gastric Suction And Intubation Laryngeal Mask With Integrated Gastric Access And Intubation. ; Oit Should Have A Reinforced Tip With Gastric Drainage Port And Should Be Used As An Intubating Laryngeal Mask For Any Brand Or Make. ; O Should Have Pilot Balloon To Identify Mask Size And To Provide Tactile Indication Of Degree Of Inflation. ; O Should Be Mr Safe And Phthalate Free Material. ; O Should Be With Integrated Bite Absorption Area For Airway Occlusion. ; O The Cuff Should Be Soft , Thin & Designed To Deliver High Seal Pressure Upto 40 Cmh20 ; O Available With Sizes 1,1.5,2,2.5,3,4,5,6 ; O Should Have Iso And Ce Marks Confirming To International Standards Of Safety. , Laryngeal Mask Preformed Laryngeal Mask Made Up Of Silicon, ; O Cuff And Tube Moulded As A Single Unit For Extra Safety ; Oit Should Have Reinforced Tip At Cuff To Avoid Kink/Bending During Insertion And To Ensure Proper Sealing, ; O It Should Be Autoclaved Up To Minimum 40 Time. ; O It Should Have Soft Cuff To Ensure Best Possible Seal With Least Possible Internal Pressure. ; O It Should Have Colour Coded Pilot Balloon To Identify Mask Size And To Provide Precise Tactile Indication Of Degree Of Inflation. ; O It Should Have Available Sizes Of 1,1.5,2,2.5,3,4,5,6 ; O Should Be Iso And Ce Certified. , Laryngeal Mask Airwayo Used For Routine And Elective Surgical Procedures. ; O Made Of Soft Pvc, Which Is Thermo-Sensitive Material, For An Atraumatic Insertion And Patient Comfort. ; O Anatomically Correct Curve For Fast And Easy Insertion. ; O Ergonomically Shaped Tube For Firm Grip During Insertion. ; O Aperture Bars To Prevent Blockage Of The Ventilation Lumen From The Epiglottis. ; O Cuff And Airway Tube Molded As One Unit For Extra Safety. ; O Soft Cuff Ensures A Good Seal With Low Mucosal Pressure. ; O Pilot Balloon Identifies Mask Size And Provides Precise Tactile Indication Of Degree Of Inflation. ; O Ventilation Tube Clearly Marked With All Information Like Mask Size, Patients Weight And Cuff Inflation Volume. ; O Supplied Sterile Individually Packed In Blister Pack Lid. , Latex Free, Mri Compatible Needle Free Devices Dou , Latex Free, Mri Compatible Needle Free Devices Trio , Latex Free, Mri Compatible Needle Free Devices Uno , Leader Cath Aeterial Line All Size , Leak & Puncture Resistant Sharps Collectors With Brackets Facilitating One Handed Disposal, Satisfying Niosh Guidelines On Sharps Disposal Containers, Made Of Nontoxic Colorants And Compliance With Coneg Heavy Metal Limits. 1.5Qt , Leak & Puncture Resistant Sharps Collectors With Brackets Facilitating One Handed Disposal, Satisfying Niosh Guidelines On Sharps Disposal Containers, Made Of Nontoxic Colorants And Compliance With Coneg Heavy Metal Limits. 1Qt , Leak & Puncture Resistant Sharps Collectors With Brackets Facilitating One Handed Disposal, Satisfying Niosh Guidelines On Sharps Disposal Containers, Made Of Nontoxic Colorants And Compliance With Coneg Heavy Metal Limits. 5.4Qt , Light Wt Layer Form Hemostate With Bactericidal 2X4 , Lightweight Elasticated Tubular Dressing For Retention With 2-Way Stretch Technology (Radial & Longitudinal Stretch) With Blue Color Coding For Identification Size. Fabric Is Of Viscose Elastane. Size- 7.5X1000 Cm , Lightweight Elasticated Tubular Dressing For Retention With 2-Way Stretch Technology (Radial & Longitudinal Stretch) With Green Color Coding For Identification Size. Fabric Is Of Viscose Elastane. Size- 5X1000 Cm , Lightweight Elasticated Tubular Dressing For Retention With 2-Way Stretch Technology (Radial & Longitudinal Stretch) With Purple Color Coding For Identification Size. Fabric Is Of Viscose Elastane. Size- 20X1000 Cm , Lightweight Elasticated Tubular Dressing For Retention With 2-Way Stretch Technology (Radial & Longitudinal Stretch) With Red Color Coding For Identification Size. Fabric Is Of Viscose Elastane. Size- 3.5X1000 Cm , Lightweight Elasticated Tubular Dressing For Retention With 2-Way Stretch Technology (Radial & Longitudinal Stretch) With Yellow Color Coding For Identification Size. Fabric Is Of Viscose Elastane. Size- 10.75X1000 Cm , Lma Diff Size, Double Lumen With Gastric Access & 100% Silicone , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 1Ml With Needle , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 2Ml With Needle , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 3Ml With Needle , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 5Ml With Needle , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 10Ml With Needle , Luer Lok Disposable Syringes:Syringe Made Of Polypropylene Plastic (Pvc Free Plastic) ; Syringe Nozzle Design: Luer Lok ; Packing: Blister With Medical Grade Paper ; Sterilized With Eto ; Polyisoprene Used As Stopper (Latex Free Syringe) ; Silicone Oil Used As Lubricant ; 20Ml Without Needle , Lumber External Csf Drainage Systems.Contains One Double Chamber Bag, Bag Anchoring Panel, One 30Cm Lumber Catheter With 14G Touhey Needle,Connecter,Suture Collar And Connecting Tube. , Malleable Stylet All Sizes , Mammography Flims Size (18X24cm) , Measured Volume Seto 100% Latex Free Set Provided With Y Type Injection Port Made Up Of Silicone For Additional Medication And Luer Slip Connector.O Equipped With A Micro Drip With Reduced Drop Size Of 60 Drops Per Ml. ; O Provided With A Burette Type Chamber Of 100 Ml Capacity With 10 Ml Overflow Limit. ; O Burette Chamber Is Made Of Bio-Compatible Medical Grade Transparent Styrene Polymer, Suitable For Infusing All Types Of Fluids. ; O Patent Design Hanger Facilitates Hanging On The I.V. Stand. ; O Unique Floating Auto Shut Off Valve Acts As A Floating Indicator And Automatically Shuts Off The Drain Path To Prevent The Passage Of Air In The Line. ; O No-Kink Device Prevents Kinking Of Tube During Transportation And Transfers. ; O Separate Plugs For Extra Medication And Change Over. ; O Sterile, Individually Packed. , Medicated Bath Wipes- Anti-Bacterial Bath Wipes Ready To Use Protecting Against Nosocomial Infection .Ingredient Chlorhexidine Gluconate Solution I.P 2% W/V , Purified Aqua, Tocopheryl Acetate, Glycerin, Phenoxyethanol, Fragrance, Aloevera Liquid Extract, Ph Stabilizers And Excipients. Ph Of Formulation: 5.5, . Material - Non Woven Fabric. Size - 32X30 Cm, Pack Of 10S In Ziplock Pack. , Melicot Catheter Diff Size , Mersilk Black Braided 76 Cm,1/2 Circle Oval Round Body Jb,Needle-26 Mm,Size-2-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,1/2 Circle Reverse Cutting,Needle-50 Mm,Size-2-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-3-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-4-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,1/2 Circle Tapercut,Needle-25 Mm,Size-2-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,3/8 Circle Cutting,Needle-60 Mm,Size-1,Box Of-12 Foils , Mersilk Black Braided 76 Cm,3/8 Circle Reverse Cutting,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,3/8 Circle Reverse Cutting,Needle-45 Mm,Size-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,3/8 Circle Reverse Cutting,Needle-45 Mm,Size-2-0,Box Of-12 Foils , Mersilk Black Braided 76 Cm,3/8 Circle Round Body,Needle-30 Mm,Size-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,1/2 Circle Round Body,Needle-16 Mm,Size-4-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,1/2 Circle Round Body,Needle-25 Mm,Size-3-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-2-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,3/8 Circle Cutting Ethiprime,Needle-16 Mm,Size-3-0,Box Of-12 Foils , Mersilk Black Braided 90 Cm,3/8 Circle Cutting Ethiprime,Needle-16 Mm,Size-4-0,Box Of-12 Foils , Mersilk Blackbraided 76 Cm,3/8 Circle Round Body,Needle-16 Mm,Size-4-0,Box Of-12 Foils , Mesh Fixation Device-Absorbable-15 Spikes , Mesh Fixation Device-Absorbable-30 Spikes , Mesh Fixation Device-Non Absorbable-15 Spikes , Mesh Fixation Device-Non Absorbable-30 Spikes , Metalic Airway (Adult) , Micro Driplnfusion Set , Micro Suction Cannula , Microlaryngeal Tube Size 5.5,6.5 , Microsensor Basic Kit (Contains Codman Microsensor Icp Transducer & 14 Gauge Touchy Needle With Stylet) (Can Be Used In Both Subdural & Intraparenchymal Pressure Monitoring Applications) , Microsensor Skull Bolt Kit (Contains Codman Microsensor Icp Transducer Along With Winged, 0.7 Mm Skull Bolt With Leak Proof Compression Cap, Spacing Washer, Obturator / Durapierce, 2.7 Mm Drill Bit, Hex Wrench) , Microsensor Ventricular Catheter Kit (Contains 38 Cm Clear Ventricular Cathetor With Preloaded Stylet, Integrated Maniature Strain Gauge Pressure Transducer, 7 Gauge Tunneling Trocar For Placement, Catheter Anchoring Clip) (In Conjunction With Icp Express Monitor This Can Be Used Wide Variety Of Patient Monitring Systems For Display Of Icp Wave Form Or For Consideration Of Icp Data With Other Vital Clinical Monitoring Information) , Microtome Blades-High Profile,Disposable Blades, Stainless Steel , Mini Closed Wound Suction Set O Close Wound Drainage Device Under Negative Pressure. ; O Suitable For Minor Surgery. ; O The Drain Has Been Provided With A Radio-Opaque Line For X-Ray Visualization. ; O Burr Free Smooth Eyes At The Distal End For Efficient Trauma Free Performance. ; O Easy To Use By One Person To Depress The Chamber To Activate The Suction Of Bellow Unit. ; O Sterile, Individually Packed., Size: 8Fg , Mist Blowero Surgical Blower Humidifier Intended For Use During Cardiac And Other Fine Surgeries. ; O Made Up Of Latex Free, Non-Toxic Medical Grade Material. ; O Specially Designed For Improving The Visibility At Anastomotic Or Other Fine Surgical Sites. ; O It Creates A Consistent And Predictable Blood Clearing Mist. ; O An Irrigation Mist Gently Clears Blood From The Site, Improving Visualization Without Drying Or Desiccating Delicate Tissue. ; O Design Of The Device Is Such That It Enables Easy Maneuverability And ; Convenient Handling. ; O Consists Of An Extra Soft Tip, Preceded By A Shaft And A Soft Textured, Ergonomic Handle Followed By A Flexible Connector Provided With A Dual Lumen Tubing That Entails Passage Of Normal Saline At Gentle Air Pressure. ; O Combination Of Fluid And Gentle Air Forms A Fine Humidifier Spray, Enabling ; Easy Visibility At The Anastomosis Sites. ; O Sterile, Individually Packed In A Box. , Mucus Extractoro Specially Designed For Aspiration Of Secretions From Oropharynx In Newly Born Babies To Ensure Free Respiration. ; O Also Ideal For Obtaining Mucus Specimen For Micro Biological Examinations. ; O Transparent Container Manufactured From Medical Grade Polypropylene. ; O Clear Transparent Container Permits Immediate Visual Examination Of The Aspirate Collected. ; O Low Friction Surface Of Catheter Is Provided With Open End Silk Smooth Round ; Tip, For Trauma Free Insertion And Suction. ; O Spare Plug Cap Is Provided To Seal The Container For Safe Transportation Of Specimen To Laboratory Or For Aseptic Disposal Of Container. ; O Sterile, Individually Packed In A Peelable Soft Blister Pack. , Multibic Solution , Multifiltrate Dialysate Line (158Ml) , Multifiltrate Substituate Line- 1Heater Bags , Mvr Blade , Mvr Vitrectomy Blade , N-95 Mask , Nasal Cannula Ojr 412-M , Nasal Cannula Ojr 412-S , Nasal Prong For Oxygen Therapy - Adult , Nasal Prong For Oxygen Therapy - Paediatric , Nasogastric Tubeplain Nasogastric Tube/ Ryles Tube. ; O The Tube Is Marked At 50, 60 And 70 Cm From The Tip For Accurate Placement. ; O Designed For Introduction Of Nutrition And Aspiration Of Gastric Contents. ; O Made Up Of Non-Toxic, Non-Irritant And Kink Resistant Medical Grade Pvc. ; O Super Smooth, Low Friction, Frozen Surface Facilitates Atraumatic Intubation. ; O Four Lateral Eyes Are Provided For Efficient Aspiration And Administration. ; O Smooth Outer Surface Also Ensures To Reduce Chances Of Tissue Irritation. ; O Distal End Is Coned With Radio Opaque Material For Easy Intubation. ; O Patented Soft Dual Port Connector At The Proximal End To Fit Easily With The Syringe Or Feeding Bag. ; O Radio-Opaque Line For X-Ray Visualization. ; O Colour Coded For Instant Size Identification. ; O Sterile, Individually Packed In Peelable Soft Blister Pack, Size: 8Fg To 20Fg , Nasopharyngeal Airway Suitable For Suctioning In I.C.Us And Provide An Alternative Way When Oro- Pharyngeal Airway Is Occluded. ; O Design Of The Tube Conforms To The Nasopharyngeal Anatomy. ; O Flexible For Maximum Patient Comfort ; O Tube Manufactured In Medical Grade Pvc Is Soft, Flexible And Kink Resistant. ; O Soft Material For Enhanced Nasal Passage Comfort. ; O Atraumatic Soft-Rounded Edges And Smooth Surface. ; O Specially Designed Bevel Tip Reduces Mucosal Trauma During Insertion. ; O Tube Marked With The Internal Diameter For Easier Size Identification. ; O Thin Wall Construction Provides Maximum Inner Diameter. ;Interior Walls With Channel Grooves Facilitate Easy Insertion Of Catheter. ; O Removable 15 Mm Connector To Allow Connection To Ventilation Systems. ;Individually Packed In Peelable Pack. , Nasopharyngeal Airway With Roatator-Diff. Size , Nasorbable Airway With Roatator-Diff.Size , Nebulizer T-Piece With 2 Mtr Oxygen Tube , Nebulizer Tubing Set , Nebulizing Masko Mask With Soft Seal And Strap For Better Fit And Comfort. ; O Manufactured From Medical Grade Pp Material, Making It Lighter Than A Pvc Mask. ; O No Unpleasant Odor As Associated With Other Masks. ; O Special Soft Seal Provides Comfort Around The Face. ; O Enables The Patient To Wear The Mask For Longer Duration. ; O The Cushion Also Provides Better Concentration As It Forms A Seal Between Facial Muscles And Mask Thereby Reducing The Wastage Of Medication. ; O Leaves Little Air Blind Angle Which Limits Breath Of Exhaust. ; O Sealing Edge Of Contour Line Greatly Eliminates Discomfort Caused By The Oppression To Facial Nerve. ; O No Metal Nose Clip, Making The Product Mri Compatible. ; O Individually Packed In Poly Bag. , Needle Bone Marrow/Puncture Needle/Bone Marrow Display Needle, Size-14/16 Gauze , Needle Certrofix (Duo) (Adult) , Needle Certrofix (Duo) (Paediatric) , Needle Certrofix (Mono) (Adult) , Needle Certrofix (Mono) (Paediatric) , Needle Certrofix (Trio) (Adult) , Needle Combined Epidural And Spinal Needle With Catheter Set , Needle Disposable For Nerve Locator Shor Bevel Needle For Plexus Anaesthesia (0.7*50Mm,18G*2) , Needle Disposable For Nerve Locator Shor Bevel Needle For Plexus Anaesthesia (0.7*50Mm,20G*2) , Needle Disposable For Nerve Locator Shor Bevel Needle For Plexus Anaesthesia (0.7*50Mm,22G*2) , Needle Epidural No 16G , Needle Epidural No 18G , Needle Epidural With Catheter Set No 16G , Needle Epidural With Catheter Set No 18G , Needle Liver,Kidney ,Pleural Biopsy Needle(Different Size) , Needle Spinal Quinckle Bibcock No 25 , Needle Spinal Quinckle Bibcock No 26 , Needle Spinal Quinckle Bibcock No 27 , Needle Trephine Biopsy Needle , Needless Iv System With Closed Luer Access Having Self Sealing Silicone Split Septum With15cm Extension Set Bi& Tri (Not Reverse Septum) And Transparent Housing. , Negative Flow Attachment , Nelataion Cathetero Designed For Short Term Bladder Catheterization Through Urethera. ; O Manufactured From Medical Grade Pvc Compatible With Catheter Lubricants. ; O Frozen Surface Tubing For Super Smooth Intubation. ; O Atraumatic, Soft Rounded And Closed Tip Catheter Facilitates Drainage. ; O Coned Distal End Ensures An Optimal Sliding Quality And Care For The Sensitive Tissue To Achieve Atraumatic Catheterization. ; O Two Lateral Eyes For Efficient Drainage. ; Oradio-Opaque Line Provided Throughout The Length Of The Catheter For Proper X-Ray Visualization. ; O Universal Funnel Shape Connector For Easy Connection To Urine Bag. ; O Colour-Coded Funnel Connector Of The Catheter Provides Instant Identification Of The Sizes. ; O Sterile, Ready For Use. Size: 6Fg To 20Fg , Neonatal Diaper , Nibp Cuff With Hose Adult , Nirs/ Cerebral Oximetry Module For Hemosphere Monitor. ; Nirs/ Cerebral Oximetry Sensors - Large ,Medium, Small, Neonatal , Niterial Gloves , Nitrile Gloves - No.- 7 , Niv Mask With Resuable Gel (S, M, L) , Non Rebreathing Mask , Non Rebrething Mask , Nylon Black Monofilament 100 Cm,1/2 Circle Reverse Cutting (Heavy),Needle-45 Mm,Size-1,Box Of-12 Foils , Nylon Black Monofilament 100 Cm,1/2 Circle Reverse Cutting (Heavy),Needle-50 Mm,Size-1,Box Of-12 Foils , Nylon Black Monofilament 150 Cm Loop,1/2 Circle Round Body (Heavy),Needle-48 Mm,Size-1,Box Of-12 Foils , Nylon Black Monofilament 25 Cm,3/8 Circle Round Body Micro-Point,Needle-4 Mm,Size-10-0,Box Of-12 Foils , Nylon Black Monofilament 30 Cm,3/8 Circle Spatulated Micro-Point 140-6 Cs-Ultima Double Needle,Needle-6 Mm,Size-10-0,Box Of-12 Foils, , Nylon Black Monofilament 38 Cm,3/8 Circle Spatulated Micro-Point Double Needle,Needle-6 Mm,Size-10-0,Box Of-12 Foils , Nylon Black Monofilament 38 Cm,3/8 Circle Spatulated Micro-Point,Needle-6 Mm,Size-10-0,Box Of-12 Foils , Nylon Black Monofilament 70 Cm,3/8 Circle Cutting Ethiprime,Needle-16 Mm,Size-3-0,Box Of-12 Foils , Nylon Black Monofilament 70 Cm,3/8 Circle Reverse Cutting,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Nylon Black Monofilament 70 Cm,3/8 Circle Reverse Cutting,Needle-45 Mm,Size-2-0,Box Of-12 Foils , Octenidine Based Wash Lotion With Neutral Ph, Tested As Per European Norms Containing Octenidine Hcl, Aqua, Cocamidopropylamine Oxide, Peg-7 Glyceryl Cocoate, Glycerin, Hydroxyethyl-Cellulose, Lactic Acid, Contains Allantoin ; For Full Body Wash - Head To Toe , Octenidine Based Wash Mitts With Pratical Hand Dimension, Tested As Per European Norms Containing Octenidine Hcl,Aqua, Glycerine, Cocamidopropylamine Oxide, Sodium Lactate, Allantoin,Ethylhexyl Glycerine, , Oesophageal Stethoscope With Continious Core Body , Open Applicator Small 20Cm Length For 100Clips , Open Applicator Small 20Cm Length For 200Clips , Open Applicator Small 20Cm Length For 300Clips , Open Applicator Small 20Cm Length For 400Clips , Operating Microscope Drainage (Sterile) , Oro-Pharyngeal Airway O Guedel Airways Are Designed To Maintain An Unobstructed Oropharyngeal Airway During Or Following General Anaesthesia And In Patients Who Are Unconscious For Other Reasons. ; O Manufactured From Non-Toxic, Non-Irritant Pe Polymer. ; O Atraumatic Soft-Rounded Edges. ; O Provides Access For The Insertion Of Suction Catheters. ; O Flexible To Ensure Dental Protection. ; O Integral Hard Bite Block Avoids Airway Occlusion And Biting Of Tongue. ; O Design Of The Tube Conforms To The Oropharyngeal Anatomy. ; O Stepless Airway Path For Easy Cleaning. ; O Bite Blocks Are Color Coded For Instant Size Identification. ; O Individually Packed In Peelable Soft Blister Pack. ; O Sterile, Ready For Use. , Oropharyngeal Guedles Airway Size 0 , Oropharyngeal Guedles Airway Size 1 , Oropharyngeal Guedles Airway Size 2 , Oropharyngeal Guedles Airway Size 3 , Oropharyngeal Guedles Airway Size 4 , Oxidized Regenerated Cellulose,1*2In Fiber , Oxidized Regenerated Cellulose,2*14In Standard , Oxidized Regenerated Cellulose,2*3In Standard , Oxidized Regenerated Cellulose,2*4In Fiber , Oxidized Regenerated Cellulose,4*4In Fiber , Oxidized Regenerated Cellulose,4*8In Standard , Oxygen Extension Tube , Oxygen Maskoxygenmask With Soft Seal And Strap For Better Fit And Comfort. ; O Manufactured From Medical Grade Pp Material, Making It Lighter Than A Pvc Mask. ; O No Unpleasant Odor As Associated With Other Masks. ; O Special Soft Seal Provides Comfort Around The Face. ; O Enables The Patient To Wear The Mask For Longer Duration. ; O The Cushion Also Provides Better Concentration Of Oxygen As It Forms A Seal Between Facial Muscles And Mask Thereby Reducing The Wastage Of Oxygen. ; O Leaves Little Air Blind Angle, Limiting Breath Of Exhaust. ; O Sealing Edge Of Contour Line Greatly Eliminates Discomfort Caused By The Oppression To Facial Nerve. ; O No Metal Nose Clip, Making The Product Mri Compatible. ; O Individually Packed In Poly Bag. , Oxygen Mask Kit , Oxygen T-Piece Kit , Oxygenator With Intergrated Filter , P M Line 150 Cm , P M Line 200 Cm , Pacing Wire , Paper Roll For Records On Multi Para Monitor , Paper Tapeo Non-Woven Microporous Surgical Tape. ; O Skin Colored Tape Is Gentle To The Skin. ; O Provided With Unique Wavy Pattern Throughout The Surface Which Allows High Air Permeability And Ensures Painless Removal. ; O Uniformly Coated With Hypoallergenic Adhesive. ; O Excellent Adhesion To The Skin Due To Superior Quality Of The Glue. ; O Tape Is Thin, Soft And Flexible For Improved Patient Comfort. ; O Tape Is Easy To Tear From Roll And Apply. ; O Easy To Peel Off From The Skin Without Causing Any Discomfort. ; O Non-Sterile, Packed In A Box. , Patient Circuit Disposable , Patient Circuit Hose Connector Tube Long Type For Ventilator , Patient Identification Band Along With Logo Of Rims For Adult & Pediatric , Patient Identification Band Along With Logo Of Rims For Mother & Baby (Combined) , Patient Identification Band Along With Logo Of Rims For Mother & Baby(Combined) , Pcn Set 10Fr , Pediatric Anaesthesia Circuit , Pediatric For Regional Oximetry , Pediatric For Regional Oximetry , Peep Valve O It Can Be Used With Manual Resuscitators, Ventilators, Anaesthesia Machines And Cpap Systemso It Should Maintain A Wide Range Of Pressure Between 1.5 - 20 Cmh2oo It Should Have 30 Mminlet Connector To Be Fitted With Any Circuit And System , Pencil Point Spinal Needlepencil Point Spinal Needle With Precision Formed Side Hole Having Sculptured And Translucent Hub. Sizes: 27G & 25G With Introducer. , Pencil Point Spinal Needle With Precision Formed Side Hole Having Sculptured And Translucent Hub. Size- 25G & 27G With Introducer. , Percutaneous Tracheostomy Kito Specially Designed Kit Permits A Safe, Fast, And Cost-Effective Percutaneous Tracheostomy Procedure With Minimal Complications. Complete Kit Consists Of : ; O Percutaneous Tracheostomy Tube ; O Dilating Forceps ; O J-Tip Guide Wire ; O Syringe-10 Ml ; O Dilating Cannula ; O Dilator ; O Scalpel ; O Cotton Tape , Percutaneous Tracheostomy Tubeo Percutaneous Tracheostomy Tube, An Artificial Airway To Provide Access To Patients Airway, Protection From Aspiration And To Provide Access To Lower Respiratory Tract For Airway Clearance. ; O Minimal Invasive Approach Leads To Small Incisions. ; O Enables The Procedure To Be Performed At The Point Of Care, When The Doctor And Patient Are Readily Available. ; O Tapered Tip For Easy Passage Into The Stoma. ; O Low-Pressure Cuff And Tip Reduce Insertion Force, And Conform To The Individual Patients Anatomy. ; O Sterile, Individually Packed In A Box. ; O Ready For Use. , Peripherally Insrted Centralvenous Polyurethane Catheter Pucc Line , Plain Sheet Material : 25 Micron Thick Pe Hygiene Film . Size :1.20 X 1.20Cmeto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life. , Plain Sheetmaterial : 25 Micron Thick Pe Hygiene Film . Size :150 X 1.20Cmeto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life. , Plain Sheet Large Material : 25 Micron Thick Pe Hygiene Film . Size :2.1 X 1.20Cmeto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life , Plain Towelmaterial : 25 Micron Thick Pe Hygiene Film . Size : 66 X 1.20Cmeto Sterlized Packing Material: 45 G Polypropylene Film One Side And Another Side 25Gsm Tyvek Paper With 5 Years Expiry Life , Plasma Filter (P1 Dry) , Plasma Filter (P2 Dry) , Plastic Dropper , Plastic Eye Shields , Plastic Slide Box , Plastic Slide Box , Pleural Catheterindwelling Pleural Catheter Of 15.5 Fr Made Up Of Silicone With Beveled Fenestration, Proprietary Safety Valve And Polyester Cuff To Prevent The Dislodgment Of The Catheter ; A.) Guidewire Introducer With Needle ; B.) J-Tip Guidewire ,60Cm ; C.) Syringe 10Cc ; D.) Peel-Away Introducer ,16Fr ; E.) Tunneler ; F.) Blue Wrap ; G.) Drainage Line With Lockable Access Tip ; H.) Needle ,17G * 2.5Cm ; I.) 5-In-1 Drainage Line Adapter And Valve Cap ; Also System Has Dressing Set Of 6 Gauze Pad (10.2Cm *10.2Cm) , Foam Catheter Pad, Needle Foam Stop , Self-Adhesive Transparent Water Proof Dressing And Chart Labels ;1000 Ml Vacuum Bottle With Active Vacuum Technology Which Drains Quickly And Comfortably Without The Need Of Gravity. , Plypropylene Mesh Size 15Cm X 15Cm , Plypropylene Mesh Size 30Cm X 30Cm , Plypropylene Mesh Size 6Cm X 11Cm , Plypropylene Mesh Size 7.6Cm X 15.2Cm , Pmma , Pocket Mask /Rescue Mask Adult Pocket Mask It Should Be Made Of Soft Medical 100% Latex Free Material It Should Be Transparent, Reusable, Easy-To-Clean It Should Have A Replaceable One-Way Valve With Bacterial Filter Valve Should Be Sterilisable It Should Be Supplied In Hard Carry Box Mask Should Be Provided With An Elastic Band To Place It Around The Patients Head (Helps Keep The Mask In Place). It Should Be Supplied In Soft Case With One Adult And One Paediatric Mask. ; With Iso And Ce Marks Confirming To International Standards Of Safety , Poliglecapron Antibacterial Monofilament Undyed 70 Cm,3/8 Circle Reverse Cutting Fs,Needle-26 Mm,Size-3-0,Box Of-12 Foils, , Poliglecapron Antibacterial Monofilament Undyed 70 Cm,3/8 Circle Reverse Cutting Ps-1 Ethiprime,Needle-24 Mm,Size-3-0,Box Of-36 Foils, , Poliglecapron Dyed Monofilament 70 Cm,1/2 Circle Oval Round Body Visi-Black Jb,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Poliglecapron Undyed Monofilament 70 Cm,1/2 Circle Oval Round Body Jb,Needle-26 Mm,Size-3-0,Box Of-12 Foils , Poliglecapron Undyed Monofilament 70 Cm,3/8 Circle Cutting Ethiprime,Needle-25 Mm,Size-3-0,Box Of-12 Foils , Polydioxanone Undyed Monofilament 45 Cm,3/8 Circle Reverse Cutting Ps 3,Needle-16 Mm,Size-4-0,Box Of-24 Foils , Polydioxanone Undyed Monofilament 45 Cm,3/8 Circle Reverse Cutting Ps 3,Needle-16 Mm,Size-5-0,Box Of-24 Foils , Polydioxanone Voilet Monofilament 150 Cm Loop,1/2 Circle Round Body (Heavy),Needle-40 Mm,Size-0,Box Of-12 Foils , Polydioxanone Voilet Monofilament 150 Cm Loop,1/2 Circle Round Body (Heavy),Needle-50 Mm,Size-1,Box Of-12 Foils , Polydioxanone Voilet Monofilament 150 Cm Loop,1/2 Circle Round Body Ctx,Needle-48 Mm,Size-1,Box Of-24 Foils , Polydioxanone Voilet Monofilament 45 Cm,1/2 Circle Round Body Rb-2,Needle-13 Mm,Size-4-0,Box Of-36 Foils , Polydioxanone Voilet Monofilament 70 Cm,1/2 Circle Round Body Ct,Needle-40 Mm,Size-0,Box Of-24 Foils , Polydioxanone Voilet Monofilament 70 Cm,1/2 Circle Round Body Mh-1,Needle-31 Mm,Size-3-0,Box Of-36 Foils , Polydioxanone Voilet Monofilament 70 Cm,1/2 Circle Round Body Rb-2 Double Needle,Needle-13 Mm,Size-5-0,Box Of-36 Foils , Polydioxanone Voilet Monofilament 70 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-3-0,Box Of-12 Foils , Polydioxanone Voilet Monofilament 70 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-4-0,Box Of-12 Foils , Polydioxanone Voilet Monofilament 75 Cm,1/2 Circle Round Body Double Needle,Needle-20 Mm,Size-3-0,Box Of-12 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Reverse Cutting (Heavy),Needle-50 Mm,Size-1,Box Of-12 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Reverse Cutting Os,Needle-40 Mm,Size-1,Box Of-12 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Round Body (Heavy),Needle-40 Mm,Size-0,Box Of-12 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Round Body (Heavy),Needle-40 Mm,Size-1,Box Of-12 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Taper Cut V-34,Needle-36 Mm,Size-1,Box Of-24 Foils , Polydioxanone Voilet Monofilament 90 Cm,1/2 Circle Tapercut V-37,Needle-40 Mm,Size-0,Box Of-24 Foils , Polyether Ether Ketone Sternal Closure Device With Needle. , Polymer Clip Extra Large,Size-400 , Polymer Clip Large,Size-300 , Polymer Clip Medium - Large,Size-200 , Polymer Clip Open Applicator 200-30 Deg , Polymer Clip Open Applicator 300-30 Deg , Polymer Clip Open Applicator 400-30 Deg , Polypropylene Blue Monofilament 100 Cm,1/2 Circle Reverse Cutting (Heavy),Needle-45 Mm,Size-1,Box Of-12 Foil , Polypropylene Blue Monofilament 100 Cm,1/2 Circle Tapercut (Heavy),Needle-30 Mm,Size-1,Box Of-12 Foil , Polypropylene Blue Monofilament 122 Cm,1/2 Circle Taper Point Mh Ethalloy Double Needle,Needle-36 Mm,Size-2-0,Box Of-36 Foil , Polypropylene Blue Monofilament 150 Cm Loop,1/2 Circle Round Body (Heavy),Needle-48 Mm,Size-1,Box Of-12 Foil , Polypropylene Blue Monofilament 150 Cm Loop,1/2 Circle Round Body,Needle-40 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 45 Cm,3/8 Circle Reverse Cutting,Needle-12 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,1/2 Circle Cc-5 (320 Microns) Double Needle,Needle-11 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,1/2 Circle Taper Point Tf Double Needle,Needle-13 Mm,Size-5-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,1/2 Circle Taper Point Tf Ethalloy Double Needle,Needle-13 Mm,Size-4-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc (220 Microns) Double Needle,Needle-9.3 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc (220 Microns) Double Needle,Needle-9.3 Mm,Size-8-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc (220 Microns) Multipass Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc Hemo-Seal Multipass Double Needle,Needle-9.3 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc-1 (282 Microns) Multipass Double Needle,Needle-13 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cc-11 (220 Microns) Double Needle,Needle-11 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Curved Round Body Ethigltde Double Needle,Needle-6 Mm,Size-7-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Curved Round Body Ethigltde Double Needle,Needle-9 Mm,Size-8-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Cutting Cc (220 Microns) Double Needle,Needle-8 Mm,Size-7-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body (282 Microns) Double Needle,Needle-13 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body (282 Microns)Bv Double Needle,Needle-11 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Bv-1 Double Needle,Needle-9 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Bv-1 Double Needle,Needle-9 Mm,Size-7-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body C-1 (282 Microns) Double Needle,Needle-13 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Visi-Black (220 Microns) Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Visi-Black (220 Microns) Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Visi-Black (320 Microns) Double Needle,Needle-13 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Round Body Visi-Black C-1 (220 Microns) Double Needle,Needle-13 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv 175-6 Ethalloy Double Needle,Needle-8 Mm,Size-8-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv 175-7 Ethalloy Double Needle,Needle-8 Mm,Size-7-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv 175-8 Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv-1 30-5 Ethalloy Double Needle,Needle-6.5 Mm,Size-8-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-6-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv-1 Ethalloy Hemo-Seal Double Needle,Needle-9.3 Mm,Size-5-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point Bv175-6 Ethalloy Double Needle,Needle-8 Mm,Size-7-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Taper Point C-1 Ethalloy Double Needle,Needle-13 Mm,Size-6-0,Box Of-36 Foil , Polypropylene Blue Monofilament 60 Cm,3/8 Circle Visi-Black Cc175-6 Double Needle,Needle-8 Mm,Size-8-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body (Heavy),Needle-30 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body (Heavy),Needle-30 Mm,Size-1,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body (Heavy),Needle-40 Mm,Size-1,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body Double Needle,Needle-25 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Round Body,Needle-25 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Tapercut,Needle-25 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,1/2 Circle Tapercut,Needle-25 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Cutting Precision Cosmetic Pc-3,Needle-15 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Cutting,Needle-22 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Reverse Cutting,Needle-45 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Round Body Double Needle,Needle-10 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Round Body Double Needle,Needle-13 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 70 Cm,3/8 Circle Round Body,Needle-16 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Round Body (320 Microns) Double Needle,Needle-13 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Round Body Cc-4 Hemo-Seal Multipass Double Needle,Needle-13 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Round Body Rb-2 Double Needle,Needle-13 Mm,Size-6-0,Box Of-36 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Round Body Rb-2 Ethalloy Double Needle,Needle-13 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Taper Point Sh-1 Ethalloy Double Needle,Needle-22 Mm,Size-3-0,Box Of-36 Foil , Polypropylene Blue Monofilament 75 Cm,1/2 Circle Taper Point Sh-1 Ethalloy Double Needle,Needle-22 Mm,Size-4-0,Box Of-36 Foil , Polypropylene Blue Monofilament 75 Cm,3/8 Circle Cc-1 (320 Microns) Double Needle,Needle-13 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,3/8 Circle Round Body C-1 (380 Microns) Double Needle,Needle-13 Mm,Size-6-0,Box Of-12 Foil , Polypropylene Blue Monofilament 75 Cm,3/8 Circle Taper Point Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-6-0,Box Of-36 Foil , Polypropylene Blue Monofilament 75 Cm,3/8 Circle Taper Point Bv-1 Ethalloy Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foil , Polypropylene Blue Monofilament 75 Cm,3/8 Circle Taper Point C-1 Ethalloy Double Needle,Needle-13 Mm,Size-6-0,Box Of-36 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Cc-25 Double Needle,Needle-26 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Double Needle,Needle-16 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Double Needle,Needle-26 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Mh-1 Double Needle,Needle-31 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Rb-1 Double Needle,Needle-17 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Rb-1 Double Needle,Needle-17 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Rb-1 Ethalloy Double Needle,Needle-17 Mm,Size-5-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Sh Double Needle,Needle-26 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body Sh2 Double Needle,Needle-20 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body,Needle-25 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Taper Point Sh Ethalloy Double Needle,Needle-26 Mm,Size-4-0,Box Of-36 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut (Heavy),Needle-30 Mm,Size-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut V-5 Double Needle,Needle-17 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut V-5 Double Needle,Needle-17 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut V-5 Double Needle,Needle-17 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut V-7 Double Needle,Needle-26 Mm,Size-3-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut,Needle-17 Mm,Size-4-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circle Tapercut,Needle-25 Mm,Size-2-0,Box Of-12 Foil , Polypropylene Blue Monofilament 90 Cm,1/2 Circletaper Point Sh Ethalloy Double Needle,Needle-26 Mm,Size-3-0,Box Of-36 Foil , Polypropylene Bluemonofilament 90 Cm,1/2 Circle Tapercut V-7 Double Needle,Needle-26 Mm,Size-2-0,Box Of-12 Foil , Polyster, Poly(P-Dioxanone)Irgacare Mp No More Than 2360?G/M Suture Various Strenght And Various Size , Polyurethane Transperent Dressing With Pad Different Size , Portable Mainstream Capnograph , Powder Free Polymer Coated Sterile Gloves, Confirms To En-550, Iso 13485, 9001, 14001,11135,2858-1, Astm D2557, Protein Content Less Than 50Meugram/Dm Square, Length 275 To 285Mm, Size- 6, 6.5, 7, 7.5 , Power Endocutter Reload Used With Endoscopic Linear Cutter, 60Mm Blue,Articulation 60 Degree Both Side And Rotation-360 Degree , Power Endocutter Reload Used With Endoscopic Linear Cutter, 60Mm Green,Articulation 60 Degree Both Side And Rotation-360 Degree , Power Endocutter Reload Used With Endoscopic Linear Cutter, 60Mm White,Articulation 60 Degree Both Side And Rotation-360 Degree , Pre Filled Saline Water:Prefilled Terminally Sterile Single Use Device For Flushing Of Catheter With 0.9% Saline Solution Having Standard 10Ml Syringe Diameter With Design To Minimize Syringe Induced Reflux. Should Be Latex & Pvc Free. The Saline Should Be Preservative Free. Size: 3Ml , Pre Filled Saline Water:Prefilled Terminally Sterile Single Use Device For Flushing Of Catheter With 0.9% Saline Solution Having Standard 10Ml Syringe Diameter With Design To Minimize Syringe Induced Reflux. Should Be Latex & Pvc Free. The Saline Should Be Preservative Free. Size: 5Ml , Pre Filled Saline Water:Prefilled Terminally Sterile Single Use Device For Flushing Of Catheter With 0.9% Saline Solution Having Standard 10Ml Syringe Diameter With Design To Minimize Syringe Induced Reflux. Should Be Latex & Pvc Free. The Saline Should Be Preservative Free. Size: 10Ml , Precision Controller With Extension Set O Flow Regulator With Extension Set For Precise Flow Control. ; O Ensures Safe Application In Demanding Critical Care Settings. ; O Reliable Flow Rate Accuracy Across The Full Adjustable Scale. ; O Ergonomic Dial Design With Ridges For Easy Grip And Adjustment. ; O Precise Flow Rate Control Of Iv Fluids With Range Of 5Ml/Hr To 250 Ml/Hr. ; O Double Scale For 10% And 40% Solution Strengths. ; O Dehp Free Soft And Kink Resistant Pvc Tubing. ; O Male Luer Connector At One End And Female Luer Connector At Other End. ; O Provided With A Latex FreeY Type Injection Port Made Up Of Silicone For Intermittent Medication. ; O Can Be Used With All Standard I.V Sets Using Luer Lock Connections. ; O Sterile And Individually Blister Packed. , Precision Infusion Set O Dehp Free I.V Set With Dial Flow Controller Specially Designed For Controlling The Flow Rates Of Fluid. ; O Eliminates The Need Of Expensive Electronic I.V. Pumps. ; O Provided With Soft And Kink Resitant Clear Pvc Tubing For Uniterrupted Flow. ; O Gentle Gravity Drive Is Self-Correcting. ; O Wide Dial Operates As Thumb Wheel Like Roller Clamp. ; O Security Door Prevents The Accidental Change Of Flow Rate. ; O Low Cost Disposable Set Provides Maximum Safety, Traditional Grip, Reliable Flow Control, And Ergonomic Shape. ; O Provided With Specialised Y Type Injection Port Made Up Of Silicone For Additional Medication. ; O Sterile, Individually Packed. , Pre-Filled Saline Water For Catheter Flushing, Preservative Free And Non-Pyrogenic Ce Certified. Latex& Pvc Free. 10Ml , Pre-Filled Saline Water For Catheter Flushing, Preservative Free And Non-Pyrogenic Ce Certified. Latex& Pvc Free. 3Ml , Pre-Filled Saline Water For Catheter Flushing, Preservative Free And Non-Pyrogenic Ce Certified. Latex& Pvc Free. 5Ml , Pressure Extension Linelow Pressure Large Bore Extension Line Made Up Of Pvc. ; O Used Primarily To Connect The Transducer System To The Indwelling Catheter. ; O Male Luer Lock At One End And 3-Way Stop Cock At Other Enabling The User To Run Two Lines Simultaneously. ; O Three Way Stop Cock May Be Used For Blood Sampling Or Extra Medication. ; O Can Sustain A Pressure Upto 7 Kg/ Cm² Or 100 Psi. ; O Sterile, Individually Packed In Blister Pack. , Pressure Extension Line Small Bore High Pressure Extension Line. ; O Made Of Clear, Non-Toxic Medical Grade Pvc Material. ; O Suitable For High Pressure Monitoring And For Connection Between Syringe Infusion Pump And Patient. ; O Multi-Purpose Extension Line Provided With Male Luerlock At One End And Female Luer Lock At Other End And Fits All Standard Equipment. ; O Luer Lock Connectors Provide Secure Fitting. ; O Can Sustain A Pressure Upto 10 Kg/ Cm² Or 140 Psi. ; O Sterile, Individually Packed In Blister Pack , Pressure Infusion Bag Heavy Duty Pressure Cuff Specially Designed For Quick Infusion/ Fluid Container Setup And Replacement. ; O Robust Pressure Cuff Facilitates Fast Fluid Transfer Suitable To Patients Indication And Paramedics Satisfaction. ; O Clear Material Enhances Visibility Of The Fluid Transfer/Flow. ; O Suitable For Pressure Up To 400Mm Of Hg. ; O Instant Venting Through The 3-Way Stop Cock Enables Quick Deflation Of The Pressure Cuff. ; O Clear, Precise Pressure Gauge Facilitates Rapid And Reliable Pressure Control. ; O Easy To Use, Hook-And-Loop Fastener Enables Easy Replacement Of Infusion Bag Without Removal Of Pressure Cuff From Drip Stand. ; O Squeeze Bulb Provided Is Supple And Easy To Operate For Fast Inflation. ; O Sterile And Individually Packed. 1000Ml , Pressure Infusion Bago Heavy Duty Pressure Cuff Specially Designed For Quick Infusion/ Fluid Container Setup And Replacement. ; O Robust Pressure Cuff Facilitates Fast Fluid Transfer Suitable To Patients Indication And Paramedics Satisfaction. ; O Clear Material Enhances Visibility Of The Fluid Transfer/Flow. ; O Suitable For Pressure Up To 400Mm Of Hg. ; O Instant Venting Through The 3-Way Stop Cock Enables Quick Deflation Of The Pressure Cuff. ; O Clear, Precise Pressure Gauge Facilitates Rapid And Reliable Pressure Control. ; O Easy To Use, Hook-And-Loop Fastener Enables Easy Replacement Of Infusion Bag Without Removal Of Pressure Cuff From Drip Stand. ; O Squeeze Bulb Provided Is Supple And Easy To Operate For Fast Inflation. ; O Sterile And Individually Packed. 500Ml , Prolene Blue60 Cm,3/8 Circle, Tp, Bv-1 Everpoint, Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foils, , Prolene Blue 2 X 75 Cm,3/8 Circle, Tp, Bv 175-6, Everpoint, Double Needle,Needle-8 Mm,Size-7-0,Box Of-12 Foils, , Prolene Blue 60 Cm,3/8 Circle, Bv 175-8, Cc Point, Everpoint, Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, C-1 , Everpoint, Double Needle,Needle-13 Mm,Size-6-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, Bv 130-5, Everpoint, Double Needle,Needle-6.5 Mm,Size-8-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, Bv 175-6, Everpoint, Double Needle,Needle-8 Mm,Size-7-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, Bv 175-6, Everpoint, Double Needle,Needle-8 Mm,Size-8-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, Bv 175-6, Everpoint, Double Needle,Needle-9.3 Mm,Size-6-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, Bv 175-8, Everpoint, Double Needle,Needle-9.3 Mm,Size-7-0,Box Of-36 Foils, , Prolene Blue 60 Cm,3/8 Circle, Tp, C-V Everpoint, Double Needle,Needle-13 Mm,Size-6-0,Box Of-36 Foils, , Proven Bactericidal Powder Hemostate 3Rm , Pulse Oxymeter , Pvc Appron , Pvc Laryngeal Mask Airway ( Lma) Size 1.0,1.5,2.0,2.5,3.0,4.0,5.0 , R.A.E Tube North Pole -4 , R.A.E Tube North Pole -4.5 , R.A.E Tube North Pole -5 , R.A.E Tube North Pole -5.5 , R.A.E Tube North Pole -6 , R.A.E Tube North Pole -6.5 , R.A.E Tube North Pole -7 , R.A.E Tube North Pole -7.5 , R.A.E Tube North Pole -8 , R.A.E Tube North Pole -8.5 , R.A.E Tube South Pole -4 , R.A.E Tube South Pole -4.5 , R.A.E Tube South Pole -5 , R.A.E Tube South Pole -5.5 , R.A.E Tube South Pole -6 , R.A.E Tube South Pole -6.5 , R.A.E Tube South Pole -7 , R.A.E Tube South Pole -7.5 , R.A.E Tube South Pole -8 , R.A.E Tube South Pole -8.5 , Raney Reusable Scalp Clip Applying Forceps , Raney Scalp Clip- Disposable & Plastic. ( 10 Clips Per Package & 20 Packages Per Case) Compatable With 205115 Raney Clip Applying Forcep) , Rebreathing Bag ( 1 Ltr/ 2Ltr) , Recorder Printer Paper For Zoll Defibillator , Redial Cannula , Reinforced Laryngeal Mask Disposable Reinforced Laryngeal Mask Having Kink Free Wire Reinforced In Flexible Tube To Eliminate The Risk Of Airway Tube Occlusion. ; O Should Have Depth Marks For Visual Control Of Correct Positioning Of The Mask. ; O Should Have Integrated Pilot Tube For Easy Handling And Insertion. ; O Availability Of Sizes From 2,2.5,3,4,5,6; O Should Be Made Up Of Phthalate Free Material; O With Iso And Ce Marks Confirming To International Standards Of Safety , Resuscitators - Adult Double Layered Resuscitator Bag Adult With Face Mask Of Size Deliver A Max. Tidal Volume Of Approximate 1300 Ml ; Volume Of O2 Reservoir Should Be Approx. 1500 Ml ; Outer Cover Of Bag Should Be 100% Latex Free. Should Be Provides Built-In- Pressure Limitation For Patient Safety. Should Be Unique Single Shutter Valve System For Reliable Functionality. Should Be Integrated With Hand Strap Which Ensures A Good Grip, Which Helps To Reduce Fatigue During Manual Ventilation. Should Be Autoclavable At 134 C°, Including The Closed Reservoir Bag. There Should Be Provision To Attach Peep Valve.Expiratory Connector Should Be 30 Mm. Should Be C€ Approved.In Paediatric Age Group Should Be Pressure-Limiting Valve With Override Cap To Release Any Extra Pressure. There Should Be Provision To Attach Pressure Manometer. ; With Iso And Ce Marks Confirming To International Standards Of Safety , Resuscitators - Paediatric/Neonate Double Layered Resuscitator Bag Adult With Face Mask Of Size Deliver A Max. Tidal Volume Of Approximate 300 Ml; Volume Of O2 Reservoir Should Be Approx. 1500 Ml/Volume Of Oxygen Reservoir Tube Should Be 100 Ml; Outer Cover Of Bag Should Be 100% Latex Free. Should Be Provides Built-In- Pressure Limitation For Patient Safety. Should Be Unique Single Shutter Valve System For Reliable Functionality. Should Be Integrated With Hand Strap Which Ensures A Good Grip, Which Helps To Reduce Fatigue During Manual Ventilation. Should Be Autoclavable At 134 C°, Including The Closed Reservoir Bag. There Should Be Provision To Attach Peep Valve.Expiratory Connector Should Be 30 Mm. Should Be C€ Approved.In Paediatric Age Group Should Be Pressure-Limiting Valve With Override Cap To Release Any Extra Pressure. There Should Be Provision To Attach Pressure Manometer. ; With Iso And Ce Marks Confirming To International Standards Of Safety , Reusable Bougie (Imported, For Et Tube Intubation) , Reusable Transparent Face Mask Transparent Facemasks (Silicon) Having Inflating Cuff For Better Air Seal. ; Fully Autoclavable, Size 0 For Anaesthesia And ; Resuscitation. With Iso And Ce Marks Confirming To International Standards Of Safety , Reuse Prevention Syringesterile Single Use Reuse Prevention Syringe With Detachable Needles Compliant To Iso 7886:4 Type Iand Type B , Flow Wrap Package Using Medical Grade Breathable Paper, Eto Sterilized Conforming To Iso 10993-7, Stopper Made Of Non-Latex Preferred Material Thermoplastic Elastomer (Tpe) , Riboflavin And Dextran Sterile Solution , Right Lens (Pc Iol ) +17D To +26D , Round Shape Band-Aid , Rt380adult Ventilator Circuit Dual Heated + Rt019 Filter + Mr290 Chamber (Box 10) Dual Heated , Rubber Sheet , Saline Set Vented With Filter, Luer Lock & Y Injection Port , Section Catheter , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 6X8 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X10 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X15 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X20 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X25 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X30 Cm , Self- Adhesive 4 Layered Absorbent Surgical Dressing With Soft Silicone Safetec Adhesive Wound Contact Layer Designed For Exuding Wounds With Wound Pad Absorption Layer Made Up Of Polyacrylate Fibres & Polyester Fibres, Wound Pad Comes With Flex Cut Techonology, Wound Pad Acquisition & Spreading Layer Made Up Of Polyethylene/Polypropylene Fibres And With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X35 Cm , Self Adhesive Polyacrylate Porous Non-Woven Cloth Fixation Dressings For Swabs, Catheters And Tubes, With Backing Material Made Up Of Hydrophobic Polyester And Protective Release Liner Made Up Of Siliconised Paper. Size- 10X1000 Cm , Self Adhesive Polyacrylate Porous Non-Woven Cloth Fixation Dressings For Swabs, Catheters And Tubes, With Backing Material Made Up Of Hydrophobic Polyester And Protective Release Liner Made Up Of Siliconised Paper. Size- 15X1000 Cm , Self Adhesive Polyacrylate Porous Non-Woven Cloth Fixation Dressings For Swabs, Catheters And Tubes, With Backing Material Made Up Of Hydrophobic Polyester And Protective Release Liner Made Up Of Siliconised Paper. Size- 5X1000 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X10 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X15 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X20 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X25 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X30 Cm , Self Adhesive Sterile Absorbent Dressing With Borders Made Up Of Polyacrylate Adhesive, With Viscose Non-Woven Wound Pad As Absorption Layer And With Polyester Nonwoven Backing Material. A Protective Release Liner Made Up Of Siliconised Paper. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 9X35 Cm , Self Seal Sterilization Pouch Transparent / White Sterilization Compatibility Gas Plasma; Included Chemical Indicators Eliminate The Need To Place Separate Indicators Within The Pouch, Saving Valuable Packaging Time Includes A Convenient Thumb Notch For Easy Opening The Triple-Sealed Design Provides Three Independent Barriers To Contamination ; Size: 4 X 14In , Self Seal Sterilization Pouch Transparent / White Sterilization Compatibility Gas Plasma; Included Chemical Indicators Eliminate The Need To Place Separate Indicators Within The Pouch, Saving Valuable Packaging Time Includes A Convenient Thumb Notch For Easy Opening The Triple-Sealed Design Provides Three Independent Barriers To Contamination ; Size: 10 X 19In , Self Seal Sterilization Pouch Transparent / White Sterilization Compatibility Gas Plasma; Included Chemical Indicators Eliminate The Need To Place Separate Indicators Within The Pouch, Saving Valuable Packaging Time Includes A Convenient Thumb Notch For Easy Opening The Triple-Sealed Design Provides Three Independent Barriers To Contamination ; Size: 8 X 16In , Self Seal Sterilization Pouch Transparent / White Sterilization Compatibility Gas Plasma Included Chemical Indicators Eliminate The Need To Place Separate Indicators Within The Pouch, Saving Valuable Packaging Time Includes A Convenient Thumb Notch For Easy Opening The Triple-Sealed Design Provides Three Independent Barriers To Contamination Size: 12.5 X 22In , Sensor Disposable For Brain Function Monitoring (25/Box) , Sensor Disposable For Continuous Hemoglobin, Ori, Pvi, Spo2, Pi (10/Box) , Sensor Disposable For Regional Oximetery (20/Box) , Side Port , Side Port Blade , Silicon Face Mask 0 To 4 Disposable , Silicon Gel Tape - For Paediatric , Silicon Laryngeal Mask Airway No 1.0,1.5,2.0 , Silicon Laryngeal Mask Airway No 2.5,3.0,4.0,5.0 , Silicon Male Extractor Catheter - Diff. Sizes. , Silicon Rubber Tubing 6Mm , Silicon Rubber Tubing 8Mm , Silicon Suprapubic Cystostomy Catheter - Sizes 16/18/20/22 , Silicone External Catheter O 100% Silicone External Catheter. ; O Soft Silicone Catheter Is Designed To Be Non-Irritating, Non-Reactive And For Soft And Gentle Feel. ; O Ergonomically Shaped And Easily Rolls Over The Penis. ; O Highly Safe And Free From Any Kind Of Allergic Reactions. ; O Transparent Material Allows Better Skin Health Monitoring While The Catheter Is In Place. ; O Provided With Soft Adhesive Strip For Proper Fixation To Penis Shaft. ; O Skin-Friendly Adhesive Helps To Maximize Wear Time And Also Prevents Accidental Detachment. ; O Gentle Adhesive Keeps The Catheter In Place Yet Allows For Easy Removal. ; O Proximal End Is Designed For Safe And Easy Connection To Urine Bag/ Leg Bag. ; O Individually Packed In Peelable Soft Blister Pack. ; O Sterile, Ready For Use. Size: Small/Medium/Large/Extra Large , Silicone Foleys Catheter- Adult100% Silicone Material Foley Catheter. ; O Inert Silicone Material Reduces Irritation For Optimal Patient Comfort For Long Term Use And Enhanced Safety. ; O Remarkably Smooth, Non-Stick Surface Of Silicone Catheter Makes It Highly ; Resistant To Encrustation. ; O Smooth Tapered Tip Of Catheter Facilitates Easy Introduction Into The Urethra. ; O Clear Material Enables Visualization Of Drained Urine. ; O Distal Eyes Are Super Smooth And Proportional To Provide Atraumatic Insertion And Are Accurately Formed To Permit Effective Drainage. ; O Hard Non Return Valve Ensures Easy Inflation And Deflation Of Balloon. ; O Symmetrical Balloon Facilitates Proper Bladder Retention. ; O Colour Coded Valve For Easy Size Identification. ; O Sterile, Individually Packed And Ready For Use. Size: 12Fg To 24 Fg , Silicone Foleys Catheter- Pediatric 100% Silicone Material Foley Catheter. ; O Inert Silicone Material Reduces Irritation For Optimal Patient Comfort For Long Term Use And Enhanced Safety. ; O Remarkably Smooth, Non-Stick Surface Of Silicone Catheter Makes It Highly ; Resistant To Encrustation. ; O Smooth Tapered Tip Of Catheter Facilitates Easy Introduction Into The Urethra. ; O Clear Material Enables Visualization Of Drained Urine. ; O Distal Eyes Are Super Smooth And Proportional To Provide Atraumatic Insertion And Are Accurately Formed To Permit Effective Drainage. ; O Hard Non Return Valve Ensures Easy Inflation And Deflation Of Balloon. ; O Symmetrical Balloon Facilitates Proper Bladder Retention. ; O Colour Coded Valve For Easy Size Identification. ; O Sterile, Individually Packed And Ready For Use. Size: 6Fg. 8Fg & 10 Fg , Sims Speculum , Single Use Tips. (8.5 Total Length And 3.5 Working Length (Isocl Lpt 8.5L 3.5Wl .25Mm Ea) , Sirolimus Eluting Bioresorbable Vascular Scaffold System With 100 Micron Strut Thickness , Size: Plain, 15Cm Macro Bore Bi - Ext Set , Size: Plain, 15Cm Macro Bore Ext Set , Size: Plain, 15Cm Macro Bore Tri - Ext Set , Skin Electrode , Skin Grafting Blades , Skin Marker Pen , Skin Marker Pen Skin Marker Pen( Thick Point Marking) Sterile Packed In Peel Open Pouches With A Flexible Scale. , Sodium Hyaluronate Ophthalmic Soulution 1.4%W/V , Sodium Hyaluronate Ophthalmic Soulution 1.8%W/V , Sp02 Probe Adult , Sp02 Probe With Extension Cable , Spinal Needle : O Spinal Needle With Key/Slot Arrangement Of Stylet And Cannula ; O Unique Translucent Window Hub Featuring Contact Clarity ; O Fitted Stylet , Spo2 Probe Peadiatric , Sponge Holding Forcep , Ss Wire Asorted Thickness , Staining Trough , Sterile Adedive Towel (Eye Drape) 70Cm X 70Cm , Sterile Adedive Towel (Eye Drape) 90Cm X 90Cm , Sterile Adhesive Towel (Eye Draps) 90Cmx90cm , Sterile Ophthalmic Irrigation Solution (Bss , Sterile Single Use Reuse Prevention Syringe With Detachable Needles Compliant To Iso 7886:4 Type Iand Type B , Flow Wrap Package Using Medical Grade Breathable Paper, Eto Sterilized Conforming To Iso 10993-7, Stopper Made Of Non-Latex Preferred Material Thermoplastic Elastomer (Tpe) 2Ml With Needle , Sterile Single Use Reuse Prevention Syringe With Detachable Needles Compliant To Iso 7886:4 Type Iand Type B , Flow Wrap Package Using Medical Grade Breathable Paper, Eto Sterilized Conforming To Iso 10993-7, Stopper Made Of Non-Latex Preferred Material Thermoplastic Elastomer (Tpe) 3Ml With Needle , Sterile Single Use Reuse Prevention Syringe With Detachable Needles Compliant To Iso 7886:4 Type Iand Type B , Flow Wrap Package Using Medical Grade Breathable Paper, Eto Sterilized Conforming To Iso 10993-7, Stopper Made Of Non-Latex Preferred Material Thermoplastic Elastomer (Tpe) 5Ml With Needle , Sterile Single Use Reuse Prevention Syringe With Detachable Needles Compliant To Iso 7886:4 Type Iand Type B , Flow Wrap Package Using Medical Grade Breathable Paper, Eto Sterilized Conforming To Iso 10993-7, Stopper Made Of Non-Latex Preferred Material Thermoplastic Elastomer (Tpe) 10Ml With Needle , Sterile Surgical Pad/Combine Dressing (Absorbent Cotton Pad With Non Woven Fabric)Size -10Cm X 20Cm , Sterile Surgical Pad/Combine Dressing (Absorbent Cotton Pad With Non Woven Fabric)Size -10Cmx10cm , Sternal Closure Device Applicator With Cutter. , Stone Basket Different Sizes , Suction Cannula (S/S) With Thumb Tip , Suction Catheter Oro-Bronchial Catheter To Remove Respiratory Secretions From A Persons Airway To Keep It Clear And Prevent Mucus Build-Up. ; O Suitable For Removal Of Secretions From Mouth, Trachea ; And Bronchial Tubes. ; O Made From Non-Toxic, Kink-Resistant Medical Grade Pvc. ; O Provided With Universal Funnel Shaped Connector For Safe Connection To The Standard Suction Equipment. ; O Atraumatic, Soft-Rounded Distal End Is Open With One Lateral Eye To Avoid Trauma During Suctioning. ; O Soft And Smooth Tubing Specially Made Using Frozen Surface Technique For Easy Insertion. ; O Color Coded Funnel End For Instant Size Identification. ; O Sterile, Peelable Soft Blister Pack ; O Size: 6,8,10,12,14,16,18 Fr , Suction Nosal , Supra Glotic Airway , Supra Glotic Endotracheal Tube With Cuff , Supra Pubic Drainage System Suprapubic Drainage Catheter. ; O Designed For Cystostomy And Supra-Pubic Drainage. ; O Manufactured From 100% Silicone. ; O Super Smooth Catheter Material Ensures Atraumatic Intubation. ; O Low Risk Of Encrustation Helps Maintain A High Level Of Drainage Performance Even When The Catheter Is Inserted For A Longer Duration. ; O Symmetrical Inflated Balloon Facilitates Self-Retention. ; O Catheter Provided With A Radio-Opaque Line Throughout Its Length For X-Ray Visualization. ; O Distally Located Lateral Eye Enables Efficient Drainage. ; O Sterile, Individually Packed In A Box. Size: 16Fg/18Fg/20Fg/22Fg , Surgical Scissors , Suturing Needle (Cuttingall Sizes 4,5,6,7,8,9,10) , Suturing Needle (Round Body All Sizes 4,5,6,7,8,9,10) , Synthetic Biodegradable Temporizing Tri-Layered, 2Mm Thick (10X10cm),Foam Matrix Of Biodegradable (Pu) Polyurethane. No Animal Proteins/Polymer Crosslinking, Inert In Infection, Not A Food Source For Bacteria. Usfda, Ec, Dcgi Approved. Easy To Apply With Sutures Or Staples. , Synthetic Biodegradable Temporizing Tri-Layered, 2Mm Thick (10X20cm),Foam Matrix Of Biodegradable (Pu) Polyurethane. No Animal Proteins/Polymer Crosslinking, Inert In Infection, Not A Food Source For Bacteria. Usfda, Ec, Dcgi Approved .Easy To Apply With Sutures Or Staples. , Synthetic Biodegradable Temporizing Tri-Layered, 2Mm Thick (20X40cm),Foam Matrix Of Biodegradable (Pu) Polyurethane. No Animal Proteins/Polymer Crosslinking, Inert In Infection, Not A Food Source For Bacteria. Usfda, Ec, Dcgi Approved. Easy To Apply With Sutures Or Staples. , Synthetic Biodegradable Temporizing Tri-Layered, 2Mm Thick (5X5cm),Foam Matrix Of Biodegradable (Pu) Polyurethane. No Animal Proteins/Polymer Crosslinking, Inert In Infection, Not A Food Source For Bacteria. Usfda, Ec, Dcgi Approved. Easy To Apply With Sutures Or Staples , Synthetic Powder Free Non-Latex Gloves, Length 280-300Mm, Gamma Sterilized,Confirms To En455-1-2000, En455-2:2015, En455-3-2015, Iso 10282:2014 & Astm D 3577:2009, Ce Mark-Mdd Class Iia/Ppe Cat.Iii All Sizes , Syringe - 2Ml ,3Ml ,5Ml, 10 Ml , T.M Paper , T-Connector , Tegaderm All Size , Temperature Monitoring And Gastric Suction Lumen 24F,32F,25 , Terumo Hydrophilic Glide Guide Wire 0.032 , Thermal Printer Paper , Thermameter , Thermovent , Thin Perforated& Transparent Film, With Wound Contact Layer Made Up Of Soft-Silicone, With Transferring Layer Made Up Of Polyurethane Film And Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 14 Days. Size- 5X7.5 Cm , Thin Perforated& Transparent Film, With Wound Contact Layer Made Up Of Soft-Silicone, With Transferring Layer Made Up Of Polyurethane Film And Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 14 Days. Size- 7.5X10 Cm , Thin Perforated& Transparent Film, With Wound Contact Layer Made Up Of Soft-Silicone, With Transferring Layer Made Up Of Polyurethane Film And Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 14 Days. Size- 10X18 Cm , Thoraci Catheter With Trocar O Designed For Quick Non-Operative Pleural And Chest Drainage. ; O Specialised Catheter Is Provided With Trocar For Easy Penetration, Placement And Handling. ; O Flat Handle Facilitates Easy Maneuverability. ; O Large Smooth Drainage Eyes For Efficient Drainage. ; O Markings Provided At 5, 10, 15 And 20 Cm From The Distal Tip To Help Ascertain The Depth Of Penetration. ; O Proximal End Is Fitted With An Universal Tapered Connector For Easy Connection ; To The Drainage Bottle. ; O Sterile, Individually Double Packed In A Peelable Pouch. Size: 12Fg/16Fg/20Fg/24Fg/28Fg/32Fg , Thoraci Drainage Cathetero Specially Designed 100% Silicone Material Thoracic Drainage Catheter. ; O Completely Non-Reactive, Inert, Extra Soft, Smooth ; Catheter Ideal For Inter-Coastal Drainage. ; O Extremely Gentle To The Body Tissues. ; O Bio-Compatible Silicone Catheter Ensures High Patient Safety And Comfort. ; O Sterile, Double Packed In Peelable Pouch Pack., Size: 16Fg/20Fg/24Fg/28Fg/32Fg , Thorasic Drainage Catheter- Diff. Size , Thorasic Drainage Catheter With Trocar - Diff. Size , Thread Cotton Thread No- 2.0 Black , Three Layered Thin Highly Absorbent Foam Dressing With Self Adherent Borders And With Soft-Silicone Wound Contact Layer, With Wound Pad Absorption And Spreading Layer Made Up Of Viscose Non-Woven Polyester Fibres, With Wound Pad Acquisition Layer Made Up Of Polyurethane Foam, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 4X5 Cm , Three Layered Thin Highly Absorbent Foam Dressing With Self Adherent Borders And With Soft-Silicone Wound Contact Layer, With Wound Pad Absorption And Spreading Layer Made Up Of Viscose Non-Woven Polyester Fibres, With Wound Pad Acquisition Layer Made Up Of Polyurethane Foam, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 5X12.5 Cm , Three Layered Thin Highly Absorbent Foam Dressing With Self Adherent Borders And With Soft-Silicone Wound Contact Layer, With Wound Pad Absorption And Spreading Layer Made Up Of Viscose Non-Woven Polyester Fibres, With Wound Pad Acquisition Layer Made Up Of Polyurethane Foam, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 7.5X7.5 Cm , Three Layered Thin Highly Absorbent Foam Dressing With Self Adherent Borders And With Soft-Silicone Wound Contact Layer, With Wound Pad Absorption And Spreading Layer Made Up Of Viscose Non-Woven Polyester Fibres, With Wound Pad Acquisition Layer Made Up Of Polyurethane Foam, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 10X10 Cm , Three Layered Thin Highly Absorbent Foam Dressing With Self Adherent Borders And With Soft-Silicone Wound Contact Layer, With Wound Pad Absorption And Spreading Layer Made Up Of Viscose Non-Woven Polyester Fibres, With Wound Pad Acquisition Layer Made Up Of Polyurethane Foam, With Polyurethane Backing Film As Water, Bacterial And Viral Barrier. A Protective Release Liner Made Up Of Polyethylene Film. Product Should Be Ce Certified. Usage- Upto 7 Days. Size- 15X15 Cm , Three Way Stop Cock Through-Hole Stop Cock Made Of Polycarbonate & Polyethylene Biomaterial, Should Withstand A Pressure Of 40 Psi, Packing Should Be In Tyvek Paper. Size: 10Cm , Three Way Stop Cock Through-Hole Stop Cock Made Of Polycarbonate & Polyethylene Biomaterial, Should Withstand A Pressure Of 40 Psi, Packing Should Be In Tyvek Paper. Size: 100Cm , Through-Hole Stop Cock Made Of Polycarbonate & Polyethylene Biomaterial, Should Withstand A Pressure Of 40 Psi, Packing Should Be In Tyvek Paper.;; Sizes : Plain, 10Cm Extension & 100Cm Extension. , Tinanium Clip Engulfs Tissue Tip To Tip Closure,Blue Small 6Clips,20Cartrides,Size 100 , Tinanium Clip Engulfs Tissue Tip To Tip Closure,Green Medium-Large 6Clips,20Cartrides,Size 300 , Tinanium Clip Engulfs Tissue Tip To Tip Closure,White Medium 6Clips,20Cartrides,Size 200 , Tinanium Clip Engulfs Tissue Tip To Tip Closure,Yellow Large 6Clips, 20Cartrides,Size 400 , Tissue Separating Dual Layer Mesh With Plcl Barrier-15*15 Square , Tissue Separating Dual Layer Mesh With Plcl Barrier-15*20 Oval , Tissue Separating Dual Layer Mesh With Plcl Barrier-20*25 Oval , Tmt Paper , Tooth Forcep , Top Syringe For Blasdder Wash , Tracheal Culture Testing Bottle. , Tracheastomy Kit C Dett All Size , Tracheostomy Tube (Cuffed) Adult , Tracheostomy Tube (Cuffed) Paediatic , Tracheostomy Tube (Plain) All Size , Tracheostomy Tube With Subglotic Suction (Adult & Paediatic) , Trans Urethral Resection Set O Y- Shaped Set For Endoscopic Irrigation During Turp Procedure (Trans Uretheral Resection Of Prostate Gland). ; O Manufactured From Non-Toxic And Non-Irritant Medical Grade Pvc. ; O Provided With Thumb Operated Clamps That Help In Quick And Smooth Changeover Of Bottles. ; O Proximal End Is Equipped With Flexible Latex Tubing For Easy Connection To ; The Endoscope. ; O Sterile, Ready For Use. ; O Individually Packed In Peelable Pouch Pack. , Transducer Protector , Transducer Set , Transparent Iv Dressing O Transparent Pu Drape Which Provides Visibility Of Skin Around Cannula. ; O High Permeability Of The Pu Film Prevents Moisture Build Up, Responsible For Bacterial Growth And Thereby Reduces The Risk Of Infection. ; O Adequate Adhesion To The Skin Due To Hypoallergenic Adhesive Quality. ; O Flexible And Gentle On The Skin. ; O The Film Ensures Excellent Cannula Stability. ; O Keeps The Cannula Site Secure, Clean, Tidy And Prevents Any Infection. ; O Convenient And Timely Visual Inspection Because Of Transparent Film. ; O Provided With A Patient Identification Sticker. ; O Easy To Peel Off After Use. ; O Sterile, Individually Packed. , Transparent Strele Dressing 6X7 Tegadram , Treachea Tee Plus (T-Piece With 2 Mtr Oxygen Tube) , Triclosan Coated Polyglactin 910 35 Cm,1/2 Circle Reverse Cutting (Heavy)Portt,Needle-23 Mm,Size-1,Box Of-12 Foils , Triclosan Coated Polyglactin 910 45 Cm,1/2 Circle Reverse Cutting Os-8,Needle-40 Mm,Size-2,Box Of-24 Foils , Triclosan Coated Polyglactin 910 45 Cm,3/8 Circle Cutting,Needle-22 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 45 Cm,5/8 Circle Cutting,Needle-16 Mm,Size-4-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 70 Cm,1/2 Circle Reverse Cutting (Heavy) Portt,Needle-23 Mm,Size-1,Box Of-12 Foils , Triclosan Coated Polyglactin 910 70 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 70 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 70 Cm,3/8 Circle Cutting Ps-1 Prime Multi Pass Ethalloy,Needle-24 Mm,Size-3-0,Box Of-36 Foils , Triclosan Coated Polyglactin 910 70 Cm,3/8 Circle Reverse Cutting Ps-1,Needle-24 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Cutting,Needle-22 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Reverse Cutting Os,Needle-36 Mm,Size-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Reverse Cutting Os,Needle-40 Mm,Size-2,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Reverse Cutting,Needle-40 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Round Body Gs,Needle-40 Mm,Size-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Round Body Gs,Needle-40 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Round Body,Needle-30 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Round Body,Needle-40 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Tapercut V-34 Ob,Needle-36 Mm,Size-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Tapercut V-37 Ob,Needle-40 Mm,Size-1,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,1/2 Circle Tapercut,Needle-36 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,3/8 Circle Cutting Ethiprime,Needle-25 Mm,Size-3-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910 90 Cm,3/8 Circle Cutting,Needle-26 Mm,Size-2-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910Antibacterial 70 Cm,1/2 Circle Round Body,Needle-20 Mm,Size-4-0,Box Of-12 Foils , Triclosan Coated Polyglactin 910Antibacterial 90 Cm,1/2 Circle Round Body,Needle-40 Mm,Size-1,Box Of-12 Foils , Triclosen/Pgl 910 Ct Braided Undyed Suture Various Strenght And Varous Size , Triple Layered Antimicrobial Foam Dressing With Silver Sulphate, Silver Content 1.2Mg/Cm2 With Active Relaease Of Silver Upto 7 Days With Soft Silicon Saftac Wound Contact Layer For Atraumatic Dressing Change. Product Should Be Ce/ Usfda Certified Size 20X20 Cm , Triple Layered Antimicrobial Foam Dressing With Silver Sulphate, Silver Content 1.2Mg/Cm2 With Active Relaease Of Silver Upto 7 Days With Soft Silicon Saftac Wound Contact Layer For Atraumatic Dressing Change. Product Should Be Ce/ Usfda Certified Size 20X50 Cm , Tripple Lumen Catheter,Std , Trypan Blue Sterile Solution Rhex- Id 1Ml(0.8Mg Intra Ocular Solution) , Tube Set Non Filtered Patient Circuit(Set Of 10) , Tur Loop Cutting , Tur Set , Twin Bore Nasal Seto Suitable For Easy Application And Efficient Administration Of Oxygen For Greater Comfort Of The Patient. ; O Manufactured From Soft, Light Weight Non-Toxic Material, Thus Non-Irritating Even In Long Term Use. ; O Improved Anatomical Fit For Increased Comfort. ; O The System Of Attachment Provides Maximum Freedom To The Patient And Leaves The Patients Mouth Free For Nutritional And Communication Purposes. ; O Multichannel Tube Ensures Continuous Supply Of Oxygen, Even If The Tube Is Accidentally Kinked. ; O Twin Prong/ Nasal Tips Are Designed To Ensure Equal Volume Of Oxygen To Both The Air Passages. ; O Soft Funnel Shaped Connector Facilitates Easy Connection To Oxygen Source. ; O Nasal Prong Ensures An Uninterrupted Flow Of Oxygen To The Patient And Offers Better Comfort For Continuous Use. ; O Non-Sterile, Individually Packed In Poly Bag. , Tyvek Pouch , Ultra And Solo (Pack Of 10) , Ultra Flux Av600 , Ultra Only (Pack Of 10) Adult , Ultra Only (Pack Of 10) Paediatric , Ultra Starter Kit (Pack Of 10) Adult Mask &Solo , Ultra Starter Kit (Pack Of 10) Paed Mask & Solo , Under Pads , Under Water Seal Drainage Bag , Underwater Seal Drainage Systemo Under Water Seal Drainage System. ; O Specially Designed Drainage Bottle Suitable For Pleural Drainage In Conjunction With Intercoastal Drainage Catheters. ; O Double Chamber And Single Chamber Compact Unit Suitable For All Cardiac And ; Thoracic Procedures. ; O Range Suitable For Management Of Major, Moderate And Minor Drainages. ; O Easy To Read Markings Help Note The Drainage Volume. ; O Clearly Marked Initial Level Ensures Effective Under Water Seal. ; O Write On Facility On The Side Of Scale Helps In Monitoring The Collected Drained Volume Precisely. ; O Suction Port Is Provided For Connection With Suction Unit. ; O Kink Resistant Large Bore Tubing Facilitates Unrestricted Flow. ; O Metallic Hangers For Easy Attachment To Patients Bedside. ; O Sterile, Individually Packed. ; Capacity: 2000Ml , Underwater Seal Drainage Systemunder Water Seal Drainage System. ; O Specially Designed Drainage Bottle Suitable For Pleural Drainage In Conjunction With Intercoastal Drainage Catheters. ; O Double Chamber And Single Chamber Compact Unit Suitable For All Cardiac And ; Thoracic Procedures. ; O Range Suitable For Management Of Major, Moderate And Minor Drainages. ; O Easy To Read Markings Help Note The Drainage Volume. ; O Clearly Marked Initial Level Ensures Effective Under Water Seal. ; O Write On Facility On The Side Of Scale Helps In Monitoring The Collected Drained Volume Precisely. ; O Suction Port Is Provided For Connection With Suction Unit. ; O Kink Resistant Large Bore Tubing Facilitates Unrestricted Flow. ; O Metallic Hangers For Easy Attachment To Patients Bedside. ; O Sterile, Individually Packed. ; Capacity: 1200Ml , Underwater Seal Drainage System Under Water Seal Drainage System. ; O Specially Designed Drainage Bottle Suitable For Pleural Drainage In Conjunction With Intercoastal Drainage Catheters. ; O Double Chamber And Single Chamber Compact Unit Suitable For All Cardiac And ; Thoracic Procedures. ; O Range Suitable For Management Of Major, Moderate And Minor Drainages. ; O Easy To Read Markings Help Note The Drainage Volume. ; O Clearly Marked Initial Level Ensures Effective Under Water Seal. ; O Write On Facility On The Side Of Scale Helps In Monitoring The Collected Drained Volume Precisely. ; O Suction Port Is Provided For Connection With Suction Unit. ; O Kink Resistant Large Bore Tubing Facilitates Unrestricted Flow. ; O Metallic Hangers For Easy Attachment To Patients Bedside. ; O Sterile, Individually Packed. ; Capacity: 500Ml , Universal Extrimity Drape , Uretric Catheter 6Fr , Uretric Catheter Open End +Closed End- Different Sizes. , Urine Bag With Measured Volume Chamber O Graduated Measured Volume Meter For Accurate Measurement Of The Urine Output. ; O Clear And Transparent Measured Volume Chamber Allows Precise Reading. ; O Urine Meter Is Directly Attached To A Two Litre Capacity Urine Bag Having Overflow Facility. ; O Fully Closed Circuit Drainage Eliminates The Risk Of Contamination. ; O Soft And Kink Resistant Pvc Tubing. ; O Universal Tapered Connector Provided Facilitates Secure Connection With The Uretheral Catheter. ; O Foldable Hanger With Tube Holder For Bed Side Hanging. ; O Sterile, Individually Packed , Urine Collection Bag - Without Hanger (For Adult) , Urine Collection Bag - Without Hanger (For Paediatric) , Urometer C Urobag With Cuff , V Cannula Fixatoro Skin Colored, Soft Breathable Fabric, Flexible And Gentle To The Skin. ; O Ergonomically Shaped. ; O Keeps The Cannula Site Secure, Clean, Tidy And Prevents Any Infection. ; O Adequate Adhesion To The Skin Due To Hypoallergenic ; Adhesive Quality. ; O Easy To Peel Free From Skin After Use. ; O Sterile, Individually Packed.I , Vaccum Section Set , Venaus Cannula , Ventilator Circuito Corrugated, Flexible And Lightweight Tubing Made Of High Quality Plastic. ; O Transparent For Easy Monitoring Of Water Build-Up Or Blockages. ; O Circuits Provides A Better Airflow And Are Cost Effective. ; O Standard Connectors For Secure Fitment With High Performance. ; O Sterile, Latex Free And Individually Packed. ; O 22 Mm Cap With 22 Mm Corrugated Tube. ; O 15Mm Male/ 22Mm Male And 15Mm Female Angle Connector With Luer Port. , Ventilator Filter , Ventricular Cannula , Ventricular External Csf Drainage System Contains One Double Chamber Bag, Bag Anchoring Panel,One 30Cm Id 1.5 Od 3.0Mm Ventricular Catheter With Stylet,Connecter, Anchoring Collar, Trocar Catheter And Connecting Tube. Eto Sterilized . , Ventriculo Peritoneal Medium Pressure With Regular Reservoir. , Venturi Mask O Variable Venturi System To Ensure Accurate Or Predicted Concentration Of Oxygen With Single Unit. ; O Often Used For Critically Ill Patients Who Require Administration Of A Specific Concentration Of Oxygen. ; O Made Up Of Medical-Grade Pvc Material, Completely Latex Free. ; O Transparent Air Entrainment Mask With Soft Anatomical Form With Easily Adjustable Elastic Strap. ; O Specially Designed Mask Has Entrainment Ports That Are Adjustable To Allow Regulation Of The Concentration Of Oxygen Administered. ; O Wide, Adjustable Strap For Proper Positioning Of Mask On The Nasal Area. ; O Provided With Rotating Type Connector For Patients Comfort. ; O Unique Spring Loaded Mechanism Locks Prescribed Concentration In Place Ensuring Safety And Correct Oxygen Concentrations. ; O Two Meter Multichannel Tube Provided, Ensures Continuous Flow Of Oxygen. ; O Non-Sterile, Individually Packed In A Polybag. , Venturi Mask With Reservpoir Bag - Adult , Venturi Mask With Reservpoir Bag - Paediatric , Vpmp Shunt , Water Inlet Filter Cat No. M395061 , Water Seal Deainage System , Water Seal Drainage System , Waterproof Wound Dressing With Non-Adherent Absorbent Pad, Transparent P.U. Film Dressing With Hypoallergenic Adhesive, Non Woven Absorbent Pad, Silicon Paper Release Liner, Size-10Cm X 10Cm , Waterproof Wound Dressing With Non-Adherent Absorbent Pad, Transparent P.U. Film Dressing With Hypoallergenic Adhesive, Non Woven Absorbent Pad, Silicon Paper Release Liner, Size-10Cm X 25Cm , Waterproof Wound Dressing With Non-Adherent Absorbent Pad, Transparent P.U. Film Dressing With Hypoallergenic Adhesive, Non Woven Absorbent Pad, Silicon Paper Release Liner, Szie-10Cm X 20Cm , Wrights Respirometer , X Ray Flim Size 08X10 , X Ray Flimsize 10X12 , Battery , Dermal Regeneration Template:Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer (Bilayer)Ce Certified, Sizes: 2In X 2In (5Cm X 5Cm),4In X 5In (10Cm X 12.5Cm),4In X 10In (10Cm X 25Cm),8In X 10In (20Cm X 25Cm) , Meshed Dermal Regeneration Template:Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer (Bilayer-Meshed)Ce Certified, Sizes: 2In X 2In (5Cm X 5Cm),4In X 10In (10Cm X 25Cm),4In X 10In (10Cm X 25Cm),8In X 10In (20Cm X 25Cm) , Dermal Regeneration Template: Single Layer: Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate Dermal Regeneration Template: Single Layer: Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate Ce Certified, Sizes:8In X 10In (20Cm X 25Cm),2In X 2In (5Cm X 5Cm),4In X 5In (10Cm X 12.5Cm),4In X 10In (10Cm X 25Cm) , Wound Matrix Thin:Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) Ce Certified, Sizes:4In X 10In (10Cm X 25Cm),4In X 5In (10Cm X 12.5Cm),2In X 2In (5Cm X 5Cm) , Programmable Valve Right Angle (Valve With Integrated Plastic Connectors & Priming Adaptor Plastic) , Programmable Valve Right Angle Unitized With 120 Cm Distal Catheter Without Siphongaurd (Comes As Valve With Integrated Plastic Connector, 14 Cm Ventricular Cathetor, Stain Less Steel Stylet, 120 Cm Distal Catheter Unitized & Priming Adaptor Plastic) , Programmable Valve Right Angle With Siphongaurd(Valve With Integrated Plastic Connectors & Priming Adaptor Plastic) , Programmable Valve Right Angle Unitized With 120 Cm Distal Catheter With Siphongaurd (Comes As Valve With Integrated Plastic Connector, 14 Cm Ventricular Cathetor, Stain Less Steel Stylet, 120 Cm Distal Catheter Unitized & Priming Adaptor Plastic) , Programmable Valve Inline Without Siphongaurd (Valve With Integrated Plastic Connectors & Priming Adaptor Plastic) , Micro Prog Valve With Rickam (Comes With 14Cm Ventricular Catheter, Stainless Steel Stylet, 120 Cm Distal Cathetor Unitized & Priming Adaptor Plastic) , Programmable Valve Micro W Rickham Res Only (Comes With Valve &Priming Adaptor Plastic) , Csf Flow Control Device , Express Cable (Connecting Cable Between Icp Monitor & Microsensor Icp Transsducer) , Microsensor Basic Kit (Contains Codman Microsensor Icp Transducer & 14 Gauge Touchy Needle With Stylet) (Can Be Used In Both Subdural & Intraparenchymal Pressure Monitoring Applications) , Microsensor Skull Bolt Kit (Contains Codman Microsensor Icp Transducer Along With Winged, 0.7 Mm Skull Bolt With Leak Proof Compression Cap, Spacing Washer, Obturator / Durapierce, 2.7 Mm Drill Bit, Hex Wrench) , Microsensor Ventricular Catheter Kit (Contains 38 Cm Clear Ventricular Cathetor With Preloaded Stylet, Integrated Maniature Strain Gauge Pressure Transducer, 7 Gauge Tunneling Trocar For Placement, Catheter Anchoring Clip) (In Conjunction With Icp Express Monitor This Can Be Used Wide Variety Of Patient Monitring Systems For Display Of Icp Wave Form Or For Consideration Of Icp Data With Other Vital Clinical Monitoring Information) , Raney Scalp Clip- Disposable & Plastic. ( 10 Clips Per Package & 20 Packages Per Case) Compatable With 205115 Raney Clip Applying Forcep) , Raney Reusable Scalp Clip Applying Forceps , Disposable Perforator- Size 14Mm/11Mm , Disposable Perforator 11Mm/8Mm , Disposable Perforator 9Mm/6Mm , Bipolar Forceps Handle Flat & Insulated , Single Use Tips. (8.5 Total Length And 3.5 Working Length (Isocl Lpt 8.5L 3.5Wl .25Mm Ea) , Adhesion Barrier Matrix For Duraplast Made From Ultra Pure Collagen For Dural Regeneration. Clinical Studies Have Shown Effective Protection Against Csf Leakage With Sutureless Closure And No Reports Of Foreign Body Reactions Or Graft Rejections Usfda Approved. Available In Many Sizes:1 X 1,1 X 3,2 X 2,3 X 3,4 X 5 , Absorbable Gelatin Sponge Film, Without Formaldehyde, Should Be Sterilized By Dry Heat. , Size: 20Cm*7Cm*.05Cm, Box Of 20 , Absorbable Gelatin Sponge Standard, Without Formaldehyde, Should Be Sterilized By Dry Heat. , Size: 7Cm*5Cm*1.0Cm, Box Of 20 , Absorbable Gelatin Sponge Special, Without Formaldehyde, Should Be Sterilized By Dry Heat. , Size: 7Cm*5Cm*0.1Cm, Box Of 20 , Absorbable Gelatin Sponge, Anal Without Formaldehyde, Should Be Sterilized By E Beam Irradiation. Size: 0.3Cm*8Cm , Box Of 20 , Absorbable Gelatin Sponge Powder Without Formaldehyde,,Size: 1Gm, Box Of 6 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, 2X14, Box Of 12 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, - 4X8, Box Of 12 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With Proven Bactericidal Property & Efficacyand Fully Absorbable In 1-2 Weeks,- 2X3, Box Of 12 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Lightweight Fibrillar/Layer Form, With Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, Fibril Material (7Layers) For Broad Surface Area Coverage. Approved By Us Fda Size 1X2 Inch, Box Of 10 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Lightweight Fibrillar/Layer Form, Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, Fibril Material (7Layers) For Broad Surface Area Coverage. Approved By Us Fda Size 2X4 Inch, Box Of 10 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Lightweight Fibrillar/Layer Form, Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, Fibril Material (7Layers) For Broad Surface Area Coverage. Approved By Us Fda Size 4X4 Inch, Box Of 10 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With High Tensile Strength And Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, , Can Be Wrapped And Sutured, Approved By Usfda,1 In X 1 In, Box Of 12 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With High Tensile Strength And With Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks,Can Be Wrapped And Sutured, Approved By Usfda, 1 In X,3.5 In, Box Of 10 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With High Tensile Strength And With Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks,Approved By Usfda, 3 In X 4 In, Box Of 24 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat With High Tensile Strength Andwith Proven Bactericidal Property & Efficacy And Fully Absorbable In 1-2 Weeks, ,Can Be Wrapped And Sutured, Approved By Usfda, 6 In X 9 In, Box Of 10 , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Structured Non-Woven Material, With Bactericidal Property. Documented Fast Hemostatis.Ease-Of-Use In Both Open And Minimally Invasive Procedures. Can Be Repositioned Easily Without Sticking To Instruments, Approved By Us Fda Size 1X2 Inches , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Structured Non-Woven Material, With Bactericidal Property. Ease-Of-Use In Both Open And Minimally Invasive Procedures. Can Be Repositioned Easily Without Sticking To Instruments, Approved By Us Fda Size 2X4 Inch , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Structured Non-Woven Material, With Bactericidal Property. Ease-Of-Use In Both Open And Minimally Invasive Procedures. Can Be Repositioned Easily Without Sticking To Instruments, Approved By Us Fda Size 4X4 Inch , All-Human (Bovine Aprotinin Free) Fibrin Sealant A) A Package- 1Mlcontaining: One Vial Each Of Bac2 (50-90 Mg/Ml Fibrinogen) And Thrombin (800-1200 Iu/Ml Human Thrombin) Frozen Solutions B) All-Human Formulation Free Of Bovine Aprotinin C) Triple-Lumen Tip To Prevent Clogging Inside The Applicator D) Maintains Predictable Fibrinogen Viscosity In A Range Of Temperatures E) Maintains Fibronectin/Fibrinogen Ratio Within Physiologic Ranges , All-Human (Bovine Aprotinin Free) Fibrin Sealant A) A Package- 2Mlcontaining: One Vial Each Of Bac2 (50-90 Mg/Ml Fibrinogen) And Thrombin (800-1200 Iu/Ml Human Thrombin) Frozen Solutions B) All-Human Formulation Free Of Bovine Aprotinin C) Triple-Lumen Tip To Prevent Clogging Inside The Applicator D) Maintains Predictable Fibrinogen Viscosity In A Range Of Temperatures. E) Maintains Fibronectin/Fibrinogen Ratio Within Physiologic Ranges , All-Human (Bovine Aprotinin Free) Fibrin Sealant Laparoscopic Tip Of 35Cm , All-Human (Bovine Aprotinin Free) Fibrin Sealant Robotic Tip Of 45Cm , All-Human (Bovine Aprotinin Free) Fibrin Sealantairless Spray Accessory , All-Human (Bovine Aprotinin Free) Fibrin Sealant Control Tip Of 4 Cm , Absorbable Gelatin Based Topical Absorbable Flowable Hemostat With 6Cc Syringe Pre-Filled With Hemostatic Matrix. With 14.3 Cm White Applicator Tip & 14.6 Cm Blue Flexible Applicator Tip , Chg Impregnated Foam Disc, Containing 250Ug Of Chg Per Mg Of Disc ,1” Disk (2.5 Cm) W/4.0 Mm Center Hole , Chg Impregnated Foam Disc, Containing 250Ug Of Chg Per Mg Of Disc , 3/4” Disk (1.9 Cm) W/1.5 Mm Center Hole , Chg Impregnated Foam Disc, Containing 250Ug Of Chg Per Mg Of Disc ,1” Disk (2.5 Cm) W/7.0 Mm Center Hole , Absorbable Adhesion Barrier, 3X4 ( C ), Box Of 10 , Absorbable Adhesion Barrier,3X4 ( C ) Single Foil , Usfda/Ece & Iso Certified Power Port Isp M.R.I. Implanted Port With Suture Plugs With Attachable 8F Chronoflex Polyurethane Open-Ended Single-Lumen Venous Catheter With Palpation Points On Septum. Sterile Pack Biocompatible Sterile Sink Resistant Material, Should Be Biocompatible. Radiopaque Marking Should Be Available. Complete Sterile Pack Including Complete Kit, Catheter Must Allowed Injection Of Contras Media At 5Ml/Sec, Allow Cvp Momnitoringf Allow. , 48Cm Curved Jaw Cordless Ultrasonic Disssector , Intermediate Sized Port With Large Septum & Silicon Filled Suture Plugs Usfda / Ece & Iso Certified, Should Be M.R.I. Compatible With Cathlock Radioopaque Ring, Attachable 8F Choroflex Polyurethane Single Lumen Venous Catheter. Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible Radiopaque Marking Should Be Available Complete Sterile Pack Including Peel Apart Percutaneous Introducer System With Complete Kit. , Intermediate Sized Port With Large Septum & Silicon Filled Suture Plugs Usfda / Ece & Iso Certified, Should Be M.R.I. Compatible With Cathlock Radioopaque Ring, Attachable 9.6F Choroflex Polyurethane Single Lumen Venous Catheter. Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible Radiopaque Marking Should Be Available Complete Sterile Pack Including Peel Apart Percutaneous Introducer System With Complete Kit. , Intermediate Sized Port With Large Septum & Silicon Filled Suture Plugs Usfda / Ece & Iso Certified, Should Be M.R.I. Compatible With Cathlock Radioopaque Ring, Attachable 8F Groshong Catheter. Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible Radiopaque Marking Should Be Available Complete Sterile Pack Including Peel Apart Percutaneous Introducer System With Complete Kit. , M.R.I. Plastic Single Lumen Port Usfda / Ece & Iso Certified, Peel-Apart Percutaneous Introducer System With Attachable Groshong 8Fr Catheter , M.R.I. Plastic Single Lumen Port Usfda / Ece & Iso Certified, Peel-Apart Percutaneous Introducer System With Attachable Open-Ended Silicone 9.6Fr Catheter ( 75 Cm Length) , M.R.I. Plastic Single Lumen Port Usfda / Ece & Iso Certified, Peel-Apart Percutaneous Introducer System With Attachable Chronoflex 8Fr Catheter , 13Cm Curved Jaw Cordless Ultrasonic Disssector , Usfda/Ece & Iso Certified Power Port Isp M.R.I. Implanted Port With Suture Plugs Having Attachable 8F Catheter With Close-Ended Single-Lumen Venous Catheter At Distal Tip And Palpation Points On Septum. Sterile Pack Biocompatible Sterile Sink Resistant Material, Should Be Biocompatible. Radiopaque Marking Should Be Available. Complete Sterile Pack Including Complete Kit, Catheter Must Allowed Injection Of Contras Media At 5Ml/Sec, Allow Cvp Momnitoringf Allow. , M.R.I. Plastic Single Lumen Port Usfda / Ece & Iso Certified, Peel-Apart Percutaneous Introducer System With Pre-Attach Open-Ended Silicone 9.6Fr Catheter ( 75 Cm Length) , M.R.I. Plastic Single Lumen Port Usfda / Ece & Iso Certified, Peel-Apart Percutaneous Introducer System With Attachable Groshong 8Fr Catheter With Open Suture Plugs , Usfda / Ece & Iso Certified, Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Sterile Pack Including Complete Kit. Chronic Hd Catheter With Split Tip Design, Insetion Lenght 14.5F, Split Tip, Straight Catheter Having Length - 19Cm , Usfda / Ece & Iso Certified, Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Sterile Pack Including Complete Kit. Chronic Hd Catheter With Split Tip Design, Insetion Lenght 14.5F, Split Tip, Straight Catheter Having Length - 23Cm , Usfda / Ece & Iso Certified, Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Sterile Pack Including Complete Kit. Chronic Hd Catheter With Split Tip Design, Insetion Lenght 14.5F, Split Tip, Alphacurve Catheter Having Length - 19Cm , Usfda / Ece & Iso Certified, Sterile Pack Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Sterile Pack Including Complete Kit. Chronic Hd Catheter With Split Tip Design, Insetion Lenght 14.5F, Split Tip, Alphacurve Catheter Having Length - 23Cm , Battery Guide , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Straight Catheter, Catheter Length - 19Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Straight Catheter, Catheter Length - 23Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Straight Catheter, Catheter Length - 27Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Straight Catheter, Catheter Length - 35Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Straight Catheter, Catheter Length - 42Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Alphacurve Catheter, Catheter Length - 19Cm , Usfda / Ece & Iso Certified, Sterile Pack, Biocompatible Sterile Kink Resistant Material Should Be Biocompatible. Complete Sterile Pack Including Preloaded Stylet Kit. Chronic Hd Catheter With Symmetric Tip Design, Insertion Length 14.5Fr, Less Than 1% Recirculation Rate, Tapered Cuff And 360 Degree Side Holes With Air Guard, Alphacurve Catheter, Catheter Length - 23Cm , 39Cm Curved Jaw Cordless Ultrasonic Disssector , Glycolide, Caprolactone And Calcium Stearoyl Lactylate -90 Absorbable Wound Closure Device 3-0 Clear 45Cm P-14 X12 , Glycolide, Caprolactone And Calcium Stearoyl Lactylate -90 Absorbable Wound Closure Device 3-0 Clear 60Cm P-14 X12 , Polyglyconate Copolymer Ofglycolic Acid Trimethylene Carbonate-Absorbable Wound Closure Device 3-0 Green 30Cm Cv-23 X12 , Polyglyconate Copolymer Ofglycolic Acid Trimethylene Carbonate-Absorbable Wound Closure Device 3-0 Green 15Cm V-20 X12 , Polyglyconate Copolymer Ofglycolic Acid Trimethylene Carbonate-Absorbable Wound Closure Device 3-0 Green 15Cm Cv-23 X12 , Polyglyconate Copolymer Ofglycolic Acid Trimethylene Carbonate-Absorbable Wound Closure Device 4-0 Green 15Cm Cv-23 X12 , Polyglyconate Copolymer Ofglycolic Acid Trimethylene Carbonate- Absorbable Wound Closure Device 0 Green 45Cm Gs-21 X12 , Copolymer Of Butylene Terephthalate And Polytetra Methylene Ether Glycol- Non Absorbable Wound Closure Device 1 Blue 45Cm Gs-21 X12 , Polyester With Absorbable Collegen Film & Pre Placed Suture -Pcox 20X15cm , Polyester With Absorbable Collegen Film & Pre Placed Suture-Parietex Pcox Thr 25X20cm , 26Cm Curved Jaw Cordless Ultrasonic Disssector , Polyester With Absorbable Collegen Film & Pre Placed Suture-Parietex Pcox Thr 30X20cm , Polyester With Absorbable Collegen Film & Pre Placed Suture-Parietex Pcox Rnd Thr 15Cm , Polyester With Absorbable Collegen Film & Pre Placed Suture-Parietex Pcox Rnd Thr 15Cm , Polypropylene Mesh-Parietene Std Pp 6X11cm X3 , Polypropylene Mesh- Parietene Std Pp 15X15cm X1 , Polypropylene Mesh-D84 Parietene Std Pp 30X30cm X1 , Polypropylene Mesh-Parietene Std Pp 15X10cm X3 , Polypropylene Mesh-Ppm1515x3 Parietene Macro Pp 15X15cm , Mesh Fixation Device -Protack* 5Mm Instrument - Titanium- Non Absorbable , Copolymer Of Glycolic Acid & Lactic Acid (Poly- Glycolide- Co-Lactide )-Mesh Fixation Device -Abs Fixation Device 30 Tacks , Generator , Linear Cutter With With Selectable Reload Stapler60mm , Linear Cutter With With Selectable Reload Stapler80mm , Linear Cutter With With Selectable Reload Stapler1000mm , Linear Cutter Cartridge 60Mm ( White) , Linear Cutter Cartridge 60Mm (Blue) , Linear Cutter Cartridge 60 (Green) , Linear Cutter Cartridge 80Mm ( White) , Linear Cutter Cartridge 80Mm ( Blue) , Linear Cutter Cartridge 80Mm ( Green) , Linear Cutter Cartridge 100Mm ( Blue ) , Linear Cutter Cartridge 100Mm ( Green) , Endoscopic Linear Cutter Stapler , Endoscopic Linear Cutter Reloads , Open Linear Stapler , Reload For Open Linear Stapler , X Ray Flimsize14X17 , Y Connector Kit ( Y Connector With Extra Long Ventricular Catheter) , Yankur Suction O Moulded Yankaur Suction Handle With Flexible Kink Resistant Tube. ; O Used For Removal Of Secretions And Blood Peri-Operatively By Providing ; Unobstructed Suction During Prolonged Use. ; O Soft Flexible Adaptors At Both Ends Of The Tube Provide Safe Grip To The Handle As Well As Suction Source. ; O Suitable For Use With Or Without Vent Control Facility. ; O Vent Port Is Closed With Tight Fit Sleeve, Which Can Be Removed By Small Incision To Shift To Vent Control System. ; O Sterile, Individually Packed In A Peelable Soft Blister Pack. ; O Available In Two Versions : Handle With Standard Tip And Crown Tip. , B P Bladesize- 10 To 27 , Cotton Bandage Size-06M X15 Cm , Liga Clip 100 , Micropore Tape 2Inch , Micropore Tape 4 Inch , Nagal Prong Oxy Set , Nebulizer Machine , Oxy Set Chield , Skin Stepler , Skin Stepler Remover , 1 Ml Syringe` , Tecustomy Tube , Urine Collection Bag With Meter , Vaccum Suction Set , Rigid Lens Power Size-15 To25 , Hydrophobic Lens Power Size-16 To 25 , Adhesive Eye Pad , Sterile Eye Drape(70Cmx90cm) , Dark Glasses , Cord Clamp , Endotracheal Tube With Subglottic Suction Size-5Mm To 9Mm , Endotracheal Tube With Cuff(Plain) Size-5Mm To 9Mm , Tracheostomy Tube With Subglottic Suction Size-5Mm To 9Mm , Oral Pharyngeal Airway Size-5Mm To 9Mm , Trusilk Typer Cutting Size-0 To2 , Close Suction Catheter Size-10Fr To 18 Fr , Nasogastric Tube Silicon Size-10 Fr To 18Fr , Folye’S Catheter Plain All Size , Folye’S Catheter Triple Lumen ( Irrigation ) Size- 16To 30Fr , Centera Cath ( Arterial Line ) Size- 16G, 18G, 20G, 22G.( Length- 15Cm/8Cm ) , Venflon Iv Cannula Size 14 To 24G , Butter Fly Iv Cannula Size 14 To 2G , Tracheostomy Mask. , Tracheostomyset Percutaneous , Tracheostomyset-Open. , Nasal Prong-Adult , Nasal Prong-Pediatric , Venture Mask , Non- Rebreathing Mask. , High Flow Nasal Cannula Size- Medium, Large, Small , Stylets ( Intubation) Size- Adult , Pediatric , , Bougie ( Intubation) Size Adult, Pediatric , Laryngoscope Battery , Water Seal Bag , Condom Catheter , Cvp Tranducer , Flow Trac , Infusar Pressure Bag , Tranducer Stand , Big Scale , Peripherally Insrted Centeral Venous Polyurethane Catheter ( Picc Line). , Pmo Line , Iv Extension Line 10 Cm- Double Lumen , Iv Fixater Transparent , Beurrettic ( Pediatric ) Set , Tegaderm Size- Large, Medium, Small , Leukoplast Size- 2 & 3 Inch , Irrigation Syringe , Cotton Ball
Contract Date: Nov 20, 2025 Contract Value : 20.00 Crore
Boards / Undertakings / PSU No of Bidders 15
41.
Power #8253435 AOC
Supply And Installation Of Electrical Equipments Supply Of Electrical Equipments And Installation Works Of Electrical And Instrumentation System For Oesc At Maps Site-1 IS:5 Colours for ready mixed paints and enamels 2 IS:104 Specification for Ready Mixed Paint, Brushing, Zinc Chrome, Priming 3 IS:191 Copper-specification 4 IS:209 Zinc Ingot- Specification 5 IS:335 New Insulating Oils-Specification 6 IS:371 Ceiling roses 7 IS:458 Precast Concrete Pipes 8 IS:513 Cold rolled low carbon steel sheets and strips 9 IS:613 Copper rods and bars for electrical purposes 10 IS:649 Methods for testing steel sheets for magnetic circuits of power electrical apparatus 11 IS:694 Polyvinyl Chloride Insulated Unsheathed And Sheathed Cables/cords With Rigid And Flexible Conductor For Rated Voltages Up To And Including 1100 V 12 IS:732 Code of practice for electrical wiring installations 13 IS:733 Chemical composition of wrought aluminium and aluminium alloy bars, rods & sections for general engineering purpose 14 IS:783 Code of practice for laying of concrete pipes 15 IS:800 Code of practice for general construction in steel 16 IS:808 Dimensions for hot rolled steel beam, column, channel and angle sections 17 IS:813 Scheme of symbols for welding 18 IS:814 Covered electrodes for manual metal arc welding 19 IS:816 Code of practice for use of metal arc welding for general construction in mild steel 20 IS:1079 Hot rolled carbon steel sheet, plate and strip specification 21 IS:1180 (Part-1) Outdoor type oil immersed distribution transformer upto and including 2500kVA, 33kV- Specification 22 IS:1239 Steel tubes, tubular and other wrought steel fittings (Part-1&2) 23 IS:1248 Direct acting indicating analogue electrical measuring instruments & their accessories 24 IS:1255 Code of practice for installation and maintenance of power cables up to and including 33kV rating 25 IS:1293 Plug and socket outlets of rated voltage up to and including 250V and rated current up to and including 16A 26 IS:1359 Electroplated Coatings of Tin- Specification 27 IS:1554 (Part-1) PVC insulated cables for working voltages up to and including 1100V 28 IS:1573 Electroplated coatings of Zinc on iron and steel 29 IS:1576 Solid pressboard for electrical purposes-specification 30 IS:1646 Code of practice for fire safety of buildings: Electrical installation 31 IS:1730 Dimensions for Steel plates, sheets strips and flats for general engineering purposes 32 IS:1852 Rolling and cutting tolerances for hot rolled steel products33 IS:1866 Mineral Insulating Oils in Electrical Equipment Supervision and Maintenance Guidance 34 IS:1893 Criteria for earthquake resistant design of structures 35 IS:1897 Copper strips for electrical purposes 36 IS:2026 (Part-1) Power transformers: Part 1 General 37 IS:2026 (Part-2) Power transformers Part 2 Temperature-rise 38 IS:2026 (Part-3) Power Transformers - Part 3 Insulation Levels, Dielectric Tests and External Clearances in Air 39 IS:2026 (Part-4) Power transformers: Part 4 Terminal marking, tappings and connections 40 IS:2026 (Part-7) Power Transformers Part 7 Loading Guide for Oil-Immersed Power Transformers 41 IS:2062 Hot rolled low, medium and high tensile structural steel 42 IS:2071 (Part-1) High voltage test techniques: Part 1 General definitions and test requirements 43 IS 2099 Bushings for alternating voltages above 1000 volts 44 IS:2362 Determination of Water by Karl Fischer Method - Test Method 45 IS 2544 Porcelain Post Insulators for systems with nominal voltages greater than 1000 V 46 IS:2551 Danger notice plates 47 IS:2584 Method of test for electrical strength of solid insulating material at power frequencies 48 IS:2629 Recommended practice for hot dip galvanizing of iron and steel 49 IS:2633 Methods for testing uniformity of coating of zinc coated articles 50 IS:2667 Fittings for rigid steel conduits for electrical wiring 51 IS:3043 Code of practice for earthing 52 IS:3347 Dimensions for Porcelain Transformer Bushings for Use in Lightly Polluted Atmospheres 53 IS:3401 Silica gel 54 IS:3480 Flexible steel conduits for electrical wiring 55 IS:3635 Methods of testing for resistance of metallic electrical resistance material 56 IS:3637 Gas operated relays 57 IS:3639 Specification for Fittings and Accessories for Power Transformers 58 IS:3646 Code of practice for interior illumination 59 IS:3837 Accessories for rigid steel conduits for electrical wiring 60 IS 3842 Application guide for electrical relays for ac systems 61 IS:3854 Switches for domestic & similar purposes 62 IS:3961 Recommended current ratings for cables 63 IS:3975 Mild steel wires, formed wires and tapes for armouring of cables 64 IS:4000 Code of practice for high strength BOLTs in steel structures 65 IS:4007 Specification for Terminals for Electronic Equipment 66 IS:4146 Application guide for voltage transformers. 67 IS:4201 Application Guide for Current Transformer 68 IS:4649 Adaptors for flexible steel conduits 69 IS:4759 Specification for hot dip galvanizing coating on structural steel and other allied products 70 IS:4826 Specification for Hot-Dipped Galvanized Coatings on Round Steel Wires 71 IS:5051 Specification for relays for electronics and telecommunication equipment. 72 IS 5082 Wrought aluminium and aluminium alloy bars, rods, tubes and sections for electrical purposes 73 IS:5216 Guide for safety procedures and practices in electrical work 74 IS:5469 Code of practice for the use of semiconductor junction devices. 75 IS:5561 Electric Power Connectors-Specification 76 IS:5578 Guide for marking of insulated conductors 77 IS-5786 Fixed resistors for use in electronic equipment 78 IS:5831 PVC insulation and sheath of electric cables 79 IS 5834 Electrical Timer Relays for Industrial Purposes 80 IS-6005 Code of Practice for Phosphating of Iron and Steel 81 IS:6665 Code of practice for industrial lighting 82 IS:6745 Method for determination of mass of Zinc coating on Zinc coated iron & steel articles 83 IS:7098 (Part-1) Cross linked polyethylene insulated PVC sheathed cables: Part 1 For working voltage up to and including 1100 V 84 IS:7098 (Part-2) Crosslinked Polyethylene Insulated Thermoplastics Sheathed Cables - Part 2 for Working Voltages from 3.3 kV up to and Including 33 kV 85 IS:8084 Interconnecting bus bars for AC voltage above 1 kV up to and including 36 kV 86 IS:8686 Static Protective Relays 87 IS:8714 Electrical Protective Relays for use in seismic areas 88 IS:9000 Basic environmental testing procedures for electronic 89 IS:8130 Conductor for insulated electric cables and flexible cords 90 IS:8910 General technical delivery requirements for steel and steel products 91 IS:9335 Cellulosic papers for electrical purposes 92 IS 9385 High voltage fuses 93 IS:9537 (Part-2) Conduits for electrical installation-Rigid steel conduits 94 IS:9567 Tin or Tin-Lead Coated Copper Wire - Specification 95 IS:10028 Code of Practice for Selection, Installation and Maintenance of Transformers 96 IS 10118 Code of practice for selection, installation and maintenance of switchgear and control gear 97 IS:10418 Drums for electric cables 98 IS 10601 Dimensions of terminals of high voltage switchgear and controlgear 99 IS:10748 Hot rolled steel strips for welded tubes and pipes 100 IS:10810 Method of test for cables 101 IS 11353 Guide for uniform system of marking and identification of conductors & apparatus terminals 102 IS:12458 Method of test for fire resistance of fire stops 103 IS:12459 Code of practice for fire protection of cable runs 104 IS:13573 (Part-1) Cable Accessories for Extruded Power Cables - Part 1 for Working Voltages for 1.1 kV upto and Including 3.3kV(E) - Test Methods and Test Requirements 105 IS:13573 (Part-2) Cable Accessories for Extruded Power Cables - Part 2 for Working Voltages for 3.3kV(UE) upto and Including 33kV(E) - Test Requirements 106 IS:13573(P art-3) Cable Accessories for Extruded Power Cables - Part 3 for Working Voltages for 3.3kV(UE) upto and Including 33kV(E) - Test Methods 107 IS 13703 LV Fuses for voltages not exceeding 1000 V ac or 1500 V dc 108 IS 14493 Multicore and symmetrical pair/ quad cables for digital communications 109 IS 14570 Electrical Measuring Transducers for Converting a.c. Electrical Quantities to Analogue or Digital Signals 110 IS:15652 Insulating Mats for Electrical Purposes — Specification 111 IS 16227 Instrument transformers 112 IS/IEC: 60255 Measuring Relays and Protection Equipment 113 IS/IEC 60529 Degree of protection provided by enclosures 114 IS/IEC 60794 Optical Fibre Cables 115 IS/IEC 60898 Electrical Accessories – Circuit-Breakers for Overcurrent Protection for Household and Similar Installations 116 IS/IEC: 60947 Specification for low voltage switchgear and control gear 117 IS/IEC 62271 High Voltage switchgear and controlgear 118 IS:62305 Protection against lightning 119 IE Rules Indian Electricity rules 120 CEA Regulations 2010 Measures Relating to Safety and Electric Supply 121 IEEE C37.20 Standard for metal enclosed switchgear 122 IEC 60034 Rotating electrical Machines 123 IEC 60255 Electrical Relays 124 IEC 61000 Electromagnetic Compatibility (EMC) 125 IEC 60688 Electrical measuring transducers for converting AC and DC electrical quantities to analogue or digital signals 126 IEC 62271- 1 High Voltage switchgear & control gear –Part 1: Common Specifications 127 IEC 62271- High Voltage switchgear & control gear –Part 100: Alternating current etc
Contract Date: Nov 11, 2025 Contract Value : 10.69 Crore
Boards / Undertakings / PSU No of Bidders 2
42.
Educational and Research Institute #8205038 AOC
Purchase Of Books For The College Central Library Tender For The Purchase Of Books For The College Central Library , Library Books (Refer Nit) , 9781009590921 Pauline Cullen 5G Mobile And Wireless Communication Technology , 9789382127581 Pramod Borole 8085 Microprocessor , 9789354661402 Kani 8085 Microprocessor And Applications 4Ed , 9781032791470 Ziemann Volker A Handson Course In Sensors Using The Arduino And Raspberry Pi , 9788121927833 Sedha A Text Book Of Applied Electronics , Bks658165 Theraja A Textbook Of Electrical Technology , 9788178001425 Bhasker A Verilog Hdl Primer 3Ed , 9788178000145 Bhasker A Vhdl Systhesis Primer 2/Ed , 9789356066137 Athawale Ad Hoc And Wilreless Sensor Network , 9788131706886 Murthy Ad Hoc Wireless Networks: Architectures & Protocols , 9789389396294 Nagoorkani Advanced Control Theory 3Ed , 9789332584464 Michael.D.Ciletti Advanced Digital Design With The Verilog , 9788126541249 Shaila Advanced Digital Signal Processing , 9789332549685 Tomasi Advanced Electronic Communications Systems , 9781259006135 Bhurchandi Advanced Microprocessors & Peripherals , 9789357460637 Raja Rao Advanced Mobile Wireless Communications : A Holistic Coverage From Basic Concepts To 5G Technologies With Iot , Bks480965 Kakani Advances In Optics , 9783540644866 Meinel Algorithm And Data Structures For Vlsi Design , 9789353502355 Roth Analog And Digital Electronics , 9789389354201 Lakshmaiah D Analog And Pulse Circuits , 9788126541980 Alok Barua Analog Signal Processing Analysis And Sysnthesis , 9789389583465 Narashiman Analysis Of Linear Control System , 9789355735164 Joshi Antenna And Wave Propagation , 9789354248474 Balanis Antenna Theory And Applications 4Ed , 9789355428820 Twomey Applied Embedded Electronics , 9788181476463 Sloss Armsystemdevelopersguide Designningand Optimizing System Software , 9781259029981 Khemani Artificial Intelligence , 9788126519934 Lavika Goel Artificial Intelligence: Concepts And Applications , 9789356063570 Russell Artificial Intelligence-4 Ed , 9781259006463 Bhargava Basic Elec & Linear Circuits , 9789389811247 Kothari Basic Electrical And Electronics Engg 2/Ed , 9781316632932 Saha Basic Electronics , 9788121925556 Theraja Basic Electronics Solid State , 9789352606467 Kothari Basic Electronics-2Ed , 9781032851181 Panigrahi Brain Computer Interface Eeg Signal Processing , 9780367267667 Nandini Building Wireless Sensor Networks , 9789353948184 Salivahanan Circuit Theory Analsis And Synthesis , 9789354662447 Kani Circuit Theory , 9789339219604 Sudhakar Circuits And Networks , 9789332542884 Weste Harris Cmos Vlsi Design 4E , 9781032851198 Raj Raman Cognitive Internet Of Things Enabling Tech Platforms , 9781259004605 Singh Communication Systems : Analog And Digital, 3Rd , 9789354640896 Haykin Communication Systems 5Ed , 9788131717592 Bali Consumer Electronics , 9788126522880 Ramachandran Control Engineering , 9780071333269 Gopal Control System , 9788123923888 Krishnamurthy Control System( Pb) , 9789389239010 Nagoor Kani Control Systems , 9789353505455 Rashid Control Systems : Analysis And Design , 9789389261868 Nagoor Kani Control Systems Engineering , 9789389185485 Kani A N Control Systems For Be/Btech Courses 5Ed , 9789355420787 Parsian Data Algorithms With Spark Recipes And Design For Scaling Up Using Pyspark , 9788178000756 Housley Data Communication And Teleprocessing System , 9789387067844 Razavi Design Of Analog Cmos Integrated Circuit-2Ed , 9789354661099 Kani Design Of Electrical Apparatus For Anna University , 9788126512331 Sam Shamugam Digital And Analog Communication System , 9780199488681 Salivahanan Digital Circuits And Design , Bks478677 Mutagi Digital Communication , 9789387511583 Nishanth Nazimudeen Digital Communication , 9789354242465 Haykin Digital Communication System , 9788131518359 George Kurian Digital Control Systems , 9780849311918 Farhat Digital Design & Computer Organization , 9789353062019 Mano Digital Design 6Ed , 9788131520710 Bignell Digital Electronics , 9789354642531 Guntha Digital First : The Six Realizations To Transform Your Business , 9789389811926 Jayaraman Digital Image Processing , 9789353062989 Gonzalez Digital Image Processing , Bks643706 Sridhar Digital Image Processing 2Ed , 9789332542525 Mano Digital Logic & Computer Design , 9789354669606 Nagoor Kani Digital Logic Circuits With Vhdl And Verilog Programs , Bks645741 Suman Digital Principles And System Design , 9780070636330 Antoniou Digital Signal Processing , 9789383635719 Reddy Digital Signal Processing , Bks642977 Rawat Digital Signal Processing , 9789332550339 Oppenheim Digital Signal Processing , 9788122436099 Kumar Digital Signal Processing , 9788131710005 Proakis Digital Signal Processing 4Ed , Bks595664 Ramesh Babu Digital Signal Processing 7Ed , 9788195268726 Senthil Kumar Digital Signal Processing And Its Applications , 9789354661006 Kani Digital Signal Processing For Anna University , 9789386668110 Ingle-Proakis Digital Signal Processing Using Matlab , 9789353167424 Salivahanan Digital Signal Processing, 4Ed , 9789356062054 Tocci Digital Systems 12Th Ed , 9789354666353 Nagoor Kani Digital Systems Design , 9788131518304 Roth Digital Systems Design Using Vhdl W/ , 9789354667688 Nagoor Kani Digital Systems Design With Access Code , 9788122436631 Kumar Digital Technology : Prin & Prac 2Ed , 9781032934198 Ranjan Ganguli Digital Twin , 9788190935630 Ashenden Digitaldesign An Embedded System Approach Using Verilog , 9789354661242 Kani Discrete Time Signal Processing For Anna University , 9781032938608 Kersting Distribution System Modeling And Analysis With Matlab And Windmila 5/E , 9781032937939 Milovanovic Driving 5G Mobile Communications With Artificial Intelligence Towards 6G , 9789388005210 Vijayalakshmi Electric Circuits Theory And Analysis , Bks643022 Rajput Electrical And Electronic Measurements And Instrumentation , 9789381075722 Bhargava Electrical Measuring Instruments And Measurement , 9788131701713 Raju Electromagnetic Field Theory & Transmission Lines , 9780521670425 Guru Electromagnetic Field Theory Fundamentals , 9788173719776 Mallikarjuna Reddy Electromagnetic Waves Transmission Lines , 9781420064476 Rothwell Electromagnetics 2/Ed , Bks662300 Awad Electronic Commerce : From Vision Tofulfillment , 9789355322067 Salivahanan Electronic Devices And Circuits , Bks411785 Bell David Electronic Devices And Circuits 5Ed , 9789332542600 Boylestad Nashelsky Electronic Devices And Circuits--11 Ed , 9789353162511 Kalsi Electronic Instrumentation And Measurement , 9789355422064 Farmer Embedded Analytics , 9789357463966 Peckol Embedded System 2Nd Ed , 9788131512241 Huang Embedded System Design Using C8051 , 9789353168025 Raj Kamal Embedded Systems 4Ed , 9788131533208 Ganesh Rao Engineering Electromagnatics , 9789353169725 Hayt Engineering Electromagnetics 9Ed , 9789357461245 Agrawal Fiber Optic Communication Systems 5Ed , 9789813346673 Keiser Fiber Optic Communications , 9788126515929 Steven O Hanlon Fintech For Dummies , 9788131200896 Agarwal Foundation Of Analogand Digital Electronic Cricuits , 9788177583922 Kalakota Frontiers Of Electronic Commerce , 9788131705735 Proakis Fundamentals Of Communication Systems , Bks660465 Anand Kumar Fundamentals Of Digital Circuits 4Ed , 9788131515457 Rajendra Prasad Fundamentals Of Electronic Engineering , 9781032728438 Kumar S. Fundamentals Of Internet Of Things , 9789353502645 Roth Fundamentals Of Logic Design , 9789360535650 Roth Fundamentals Of Logic Design , 9789389811223 Naidu High Voltage Engineering , 9789355324320 Arun Sharma How To Prepare For Data Interpretation For Cat 8Th Ed , 9789355325112 Arun Sharma How To Prepare For Logical Reasining For Cat 7Th Ed , 9788126509096 Muralidhar Kulkarni, K S Shivaprakasha Information Theoryand Coding,As Per Aicte , 9789385880520 Reddy Instrumentation & Control Systems , 9781032599144 Fadi Internet Of Nanothings And Wireless Body Area Networks , 9789388991018 Shriram Vasudevan Internet Of Things 2Ed , 9788173719547 Vijay Madisetti Internet Of Things: A Hands On Approach , 9789390727384 Raj Kamal Internet Of Things-2Ed , 9781032728100 Roy M. Interoperability In Iot For Smart Systems , 9789339219680 Shibu Intro To Embedded Systems--2Ed , 9788131703069 Charniak Introduction To Artificial Intellegence , 9789351073192 Grami Introduction To Digital Communication 1St Ed , 9781316644010 Ghatak Ajoy Introduction To Fiber Optics , 9789381075920 Braun Introduction To Instrumental Analysis 2/Ed , 9781009200813 Sneh Saurabh Introduction To Vlsi Design Flow , 9788131516706 Agarwal Introduction To Wireless And Mobile , 9789353160487 Salivahanan Linear Integrated Circuits , 9788126518968 Nair Linear Integrated Circuitsanalysis Design & Applications , 9789354643606 Motwani Machine Learing For Text And Image Data Analysis , 9789355429292 White Making Embedded Systems 2Ed , 9780849371899 Sanchezjulio Microcontroller Programming: The Microchip Pic , 9788126548354 Rafiquzzaman Microcontroller Theory And Application With The Pic , 9789354601637 Neamen Microelectronics , 9789332577497 Rafiquzzaman Microprocessors : Theory And Application , 9789354660924 Kani Microprocessors And Microcontrollers 3Ed , 9788177583533 Liao Microwave Devices & Circuits 3Ed , 9789390113347 Das Microwave Engineering 4Ed , 9789351070306 Clerck Mimo Wireless Networks 2Ed , 9788126534869 Andrzej Mixed Signal Systems A Guide To Cmos Circuit , 9780070635999 Lee Mobile Cellular Telecomm 2E , 9788131724262 Schiller Mobile Communications, 2Ed , 9788131731666 Garg Mobile Computing , 9788131518854 Proakis Modern Communication System Using M , 9789360748128 Gopal Modern Control System Theory 5Ed , 9789355321770 Jain Modern Digital Electronics-5Th Edtion , Bks482550 Gulati Modern Television 5Ed , 9789353166724 Singh Network Analysis And Synthesis, 2Ed , 9789353433123 Van Valkenburg/ Rathode Network Analysis Revised 3Ed , 9788122420364 Wadhwa Network Analysis Synthesis , 9788196874339 Charlie Kaufman Network Security : Private Communication In A Public World , 9781259006166 Kumar Neural Networks , 9789332570313 Haykin Neural Networks And Learning Machines , 9780195696134 Bell Operational Amplifiers & Linear Ics, 3Ed , 9781316610046 Singal Optical Fiber Communication , 9789388178860 Kakani Optical Fiber Communication , 9788131732663 Senior Optical Fiber Communication Principles , 9781138569515 Binh Optical Fiber Communication Systems With Matlab And Simulink Models, 2Ed , 9789380501376 Ramaswami Optical Networksanew Perspective , 9789354667947 Chakrabarti Optoelectronic Devices And Optical Fiber Communication , 9789332902626 Singh Optoelectronics An Introduction To Materials And Devices , 9788131530788 Varmah Power Electronics , 9789353165116 Kothari Power System Engineering 3 E , 9789355429742 Jarmul Practical Data Privacy , 9789391910709 Sri Hari Piratala Principles Of Digital Communication Pb , 9789390113866 Kasap Principles Of Electronic Materials , Bks504954 Mehta Principles Of Electronics 12E , 9789354248429 Dale Seborg Process Dynamics And Control 4Ed , 9788131525906 Farrell Programming Logic And Design , 9781420072051 Pries Project Management Of Complex And Embedded Systems , 9781138625822 Qing Li Real Time Concepts For Embedded Systems , 9781420078688 Minoli Satelitte System Engineerin , 9789354243035 Pratt Satellite Communications , 9788120321984 Patranabis Sensors And Transducers , 9789351073994 Bensky Short Range Wireless Communication 3Ed , 9789354661488 Kani Signal And Systems , 9789354661013 Nagoor Kani Signal And Systems Simplified 2Ed , Bks662299 Anand Kumar Signals & Systems 3Ed , Bks505218 Ramesh Babu Signals And Systems5ed , 9789332550230 Oppenheim Signals And Systems 2/Ed , 9781138570894 Sadiku Signals And Systems A Primer With Matlab , 9788178000169 Lathi Signals System And Communication , 9788187134831 Gupta Solid State Physics And Electronics , 9788126540389 Dr. Shaila D. Apte Speechand Audio Processing,As Per Aicte , 9789357460576 Saxena The 00001 Cfo , 9788131502006 Ayala The 8051 Microcontroller , 9788177584813 Triebel The 8088 & 8086 Microprocessors : Programming , Interfacing, Software, Hardware & Applications 4Ed , 9789351071754 Yiu The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors , 9780521613897 Lee The Design Of Cmos Radio Frequency Integrated Circuits , 9780824799113 Yeshwant Transmission Network Protection , 9780070483576 Khandpur Troubleshooting Electronic , 9788177589184 Palnitkar Verilog Hdl 2Ed +Cd , 9788178000114 Bhasker Verilog Hdl Synthesis A Practical Primer , 9781032906003 Basan Babu Vlsi Circuits And Embedded Systems , 9780849318764 Michael Vlsi Design , 9788126558551 Sunilkumar S.Manvi Wireless And Mobile Networks 2Nd Ed , 9780521704168 Goldsmith Wireless Communication , 9788131218891 Garg Wireless Communicationsand Networking , 978-9332585225 Stallings Wireless Communications & Networks , 9789354248795 Molisch Wireless Communications 2Ed , 9788131520123 Mullett Wireless Telecommunication System & Network , 9781032663159 Saad Asif 5G Mobile Communications Concepts And Technologies , 9781032937908 Rogers A First Course In Machine Learning 2/E , 9780367237370 T Herman A Functional Start To Computing With Python , 9788126504442 David Karlins, Eric Matisoff Adobe Analytics For Dummies , 9781259006135 Bhurchandi Advanced Microprocessors & Peripherals , 9789332575905 Stevens Advanced Programming In The Unix Environment 3/Ed , 9789390078202 Kale Advances In Computer Vision And Information Technology , 9789355422323 Plunkett Ai At The Edge : Solving Real World Problems With Embedded Machine Learning , 9789357469975 Anthony Ai Strategy To Execution , 9780199456666 Harsh Algorithms Design And Analysis , 9780521670357 Gusfield Algorithms On String, Trees And Secquence , 9781032785905 Chuck Easttom An In Depth Guide To Mobile Device Forensics , 9788131532508 Johnson An Intro To Java Programming And Object , 9789353500931 Rahul Dubey An Introduction To Internet Of Things , 9788184890150 Seed An Introduction To Object Oriented Programming In C++2Ed , 9788126557868 Michael Burton Android App Development For Dummies 3Ed , 9789351194095 Kothari Android Application Development (With Kitkat Support) Black Book. , 9788131519035 Sheusi Android Application Development For Java Programmers , 9788126557042 Charles Elliott Smith Anger Management For Dummies 2Ed , 9788131531976 Bronson Ansi C Programming , 9781032603339 Pethuru Raj Applied Learning Algorithms For Intelligent Iot , 9789354601590 Gopal Applied Machine Learning , 9789332553941 Larman Applying Uml Patterns , 9788181476463 Sloss Armsystemdevelopersguide Designningand Optimizing System Software , 9788131267639 Nilsson Artifcial Intelligence : A New Synthesis , 9788181471901 Nilsson Artifical Intelligence : A New Sysnthesis , 9788197817823 Panneerselvam Artificial Intelligence , 9788196544577 Elaine Rich Artificial Intelligence , 9789356069329 Thareja Artificial Intelligence , 9781032939704 Jiang Artificial Intelligence 2/E , 9788126576104 Paul Artificial Intelligence For Dummies , 9789355730428 Saroj Kaushik Artificial Intelligence, 2Ed , 9788126519934 Lavika Goel Artificial Intelligence: Concepts And Applications , 9789356063570 Russell Artificial Intelligence-4 Ed , 9781718502093 Sweigart Automate The Boring Stuff With Python 2Ed , 9788126570850 Mueller Aws For Developers For Dummies , 9789355424280 Salehi Azure Cookbook , Bks642062 Burd Beginning Programming With Java For Dummies 5Ed , 9788126565757 Radha Big Data Analytics 2Ed , 9788126543281 Hurwitz Big Data For Dummies , 9789351198062 Nathan Warren Big Data Principles & Best Practices Of Scalable Real Time Data Systems , 9781032906416 Stefano Tempesta Stephen Ashur Blockchain Applied Practical Technology And Use Cases Of Enterprise Blockchain For The Real World , 9788126599967 Choudhari Blockchain For Enterprise Application Developers , 9781032906454 David Metcalf Blockchain In Healthcare Innovations That Empower Patients, Connect Professionals And Improve Care , 9789389211634 Chandramouli Subramanian Blockchain Technology , 9789357461726 Asharaf Blockchain Technologyalgorithms And Applications , 9788126557660 Saxena Blockchain Technology Concepts And Applications , 9789355429865 Kilroy Blockchain Tethered Ai : Trackable Traceable Artificial Intelligence And Machine Learning , 9781593276515 Davies Book Of R A First Course In Programming And Statistics , 9781484284650 Raina Building An Effective Data Science Practice : A Framwork To Bootstraf And Manage A Successful Data Science Prctice , 9789390168385 Yuan Building Blockchain Apps , 9789355426628 Currie Building Green Software , 9789351199397 Dominique Building The Web Of Things With Examples In Node Js And Raspbeerry , 9789355327888 Sachan Business Statistics Using Python , 9788178002842 Subramanyam C And C++ Programming Concepts And Data Structures , 9789357059565 Deitel C How To Program With Case Studies In App , 9789332585737 Deitel C++ How To Programming, 10Ed , 9788119847181 William Certfied Ethical Hacker ( Ceh ) Exam Cram , 9788120337312 Samanta Classic Data Structures , 9788120352131 Pachghare Cloud Computing , 9788131725337 Miller Cloud Computing , 9781316638101 Bhowmik Cloud Computing , 9789360533953 Elayidom Cloud Computing &Big Data , 9788126570966 Kumar Saurabh Cloud Computing 4Th Ed :Architecting Next-Gen Transformation Paradigms , 9789383635047 Rajeswara Cloud Computing And Virtualization P/B , 9788126570553 Daniel Kirsch Hurwitz Cloud Computing For Dummies , 9788126553068 Rishabh Sharma Cloud Computing Fundamentals Industry Approach And Trends , 9788131776513 Srinivasan Cloud Computing: A Practical Approach For Learning And Implementation , 9789355423832 Storment Cloud Finops 2Ed Collaborative Real Time Cloud Value Decision Making , 9789355427335 Vaughan Cloud Native Development With Google Cloud , 9781032939902 Achary Cloud Reliability Engineering: Technologies And Tools , 9781032938868 Gupta Cloud Security Concepts Applications An Perspectives , Bks642060 Minnick Coding With Java Script For Dummies , 9781680507225 Wengrow Common Sense Guide To Data Structures And Algorithms 2Ed Level Up Your Core Programming Skills A , 9789388934343 Sudha Rani S, Karthi M, Rajkumar Y Compiler Design , 9789357054119 Aho Compilers 2Ed Updated Edtion , 9788131715437 Mir Computer & Communications Networks , 9788131516157 Juneja Computer Fundamentals And C Programming , 9789332519343 Goel Computer Fundamentals And Programming In C , 9788177587654 Hearn Computer Graphics , C Version, 2Ed , 9789353068967 Hughes/Foley Computer Graphics: Principles And Practices , 9789352869152 Douglas E Comer Computer Network & Internets, 6/E , 9789380501932 Peterson Computer Network-A System Approach 5/Ed , 9788131509869 Dave Computer Networks , 9789356063600 Tanenbaum Computer Networks 6Ed , 9789390395095 Toradmalle Computer Networks And Network Design , 9788131524756 Clement Computer Organization & Architecture , 9789356061590 Stallings Computer Organization And Architecture-11Th Ed , 9789351073963 Patterson Computer Organization And Design 6/Ed , 9789355323729 Hamacher Computer Organization And Embedded Systems 6Th Ed , 9788126509836 Dr. M. Usha, T.S. Srikanth Computer System Architecture And Organization, As Per Aicte , 9789332585607 Morris, Mano Computer System Architecture, 3/Ed Update , 9789332550117 Forsyth Ponce Computer Vision A Modern Approach, 2Ed , 9788131267653 Wolf Computers As Components: Principles Of Embedded Computing System Design , 9789356814196 Gkp Converging Technologies By Prof , 9789351199250 Nageswara Rao Core Java : An Integrated Approach, New , 9788119847334 Horstmann Core Java Vol - I : Fundamentals 12Ed , 9788119847433 Horstmann Core Java Volume Ii Advancedfeatures 12 Th Ed , 9789332555365 Chun Core Python Application Programming , 9789388991155 Kiana Danial Cryptocurrency Investing For Dummies , Bks662304 Pachghare Cryptography And Information Security, 3Ed , 9789332543645 Bose Cryptography And Network Security , 9788126522859 Shyamala Cryptography And Security , 9780367148591 Stinson Cryptography Theory And Practice 4/E , 9789355429704 Meyer Css The Definitive Guide 5Ed , 9780199489442 Dejey Cyber Forensics , 9789391818463 Chander Cyber Laws It Protection , 9781032793030 Henrique Santos Cyber Security , 9789390395750 Jain Cyber Security And Cyber Laws , 9789387511675 Nadine Basta Cyber Security And Cyber Laws , 9788126521791 Godbole Cyber Security Understanding Cyber Crimes, Computer Forensics , 9788126560127 Nina Godbole Cyber Threats In Healthcare Understanding Risks And Mitigation , 9788126502950 Bharti Motwani Data Analytics Using Python , 9789352605248 Acharya Data Analytics Using R , 9788126576463 Bharti Motwani Data Analytics With R , 9789332586932 Stallings Data And Computer Communications 10Ed , 9789360536091 West Data Communications And Computer Networks 9/Ed , 9789355320940 Forouzan Data Communications And Networking-6Th Ed , 9788177587852 Dunham / Sridhar Data Mining : Introductory And Advanced Topics , 9781108727747 Parteek Bhatia Data Mining And Data Warehousing : Principles And Practical Techniques , 9789357461672 Bruce Peter Data Mining For Business Analytics Concepts,Techniques And Applications In Python , 9788131519554 Du Hongbo Data Mining Techniques And Application , 9788126533367 Ulrika Jagare Data Sciencestrategy For Dummies , 9789354600333 Thareja Data Science And Machine Learning With R , 9789388991209 Paul Mueller Data Science Programmingal In One For Dummies , 9788131714744 Weiss Data Structures & Algorithm Analysis In C++ 3Ed , 9788177588262 Aho Data Structures & Algorithms , 9788131503140 Gilberg Data Structures : A Pseudocode Approach With C , 9789360539641 Drozdek Data Structures And Algorithms , 9789354247934 Goodrich Data Structures And Algorithms In Java 6Ed , 9789354247866 Goodrich Data Structures And Algorithms In Python , 9781009276979 Subrata Saha Data Structures And Algorithms Using Python , 9789354977190 Reema Thareja Data Structures Using C 3Ed , 9788126577149 R. Venkatesan, S. Lovelyn Rose Data Structures, 2Ed , 9789354643132 Sringeswara Data Visualization : Storytelling Using Data , 9789355733979 Cochran Data Visualization Exploring And Ex , 9789390727506 Silberschatz Database System Concepts 7Th Ed , 9789353438913 Connolly Database Systems6thedn , 9789332518674 Garcia Molina Database Systems : The Complete Book2ed , 9789356061972 Gopal Deep Learning , 9789355424273 Howard Deep Learning For Coders With Fastai & Pytorch , 9789355424976 Kaabar Deep Learning For Finance , 9788126579914 Ashok Kumar Deep Learning Using Python , 9789354642401 Sharma Deep Learning With Tensorflow Js Projects , 9788126579969 Acharya Demystifing Nosql , 9789354248481 Roberto Tamassia Design And Analysis Of Algorithms , 9789332518735 Sheiderman Designing The User Interface , 9788126553495 Emily Freeman Devops For Dummies , 9789355420794 Chin Devops Tools For Java Developers Best Practices From Source Code To Prodction Containers , 9788126579952 Gaikwad Devops Tools From Practitioners Viewpoint , 9789353062019 Mano Digital Design 6Ed , 9788126578399 Dr. Nilakshi Jain, Dr. Dhananjayr. Digital Forensic , 9789332542525 Mano Digital Logic & Computer Design , 9789353433055 Ralph Grimaldi Discrete And Combinatorial Mathematics , 9789390727353 Rosen Discrete Mathematics And Its Applications 8Th Ed , Bks323747 Sunita Distributed Computing , 9781107648906 Kshemkayani Distributed Computing , 9789332549807 Tanenbum Van Steen Distributed Systems Principles , 9789391820244 Kumar Pawan Dive Into The World Of Blockchain Technology , 9789355423962 Oggl Docker Practical Guide For Developers And Devops Teams , 9789355423955 Kane Docker Up & Running 3Ed , 9788126576128 Rose Enterprise Agility For Dummies , 9788126520107 Anami Formal Languages And Automata Theory , 9789383635788 Srinivasa Formal Languages And Automata Theory P/B , 9788126519910 Mayor Ramgir Full Stack Java Development With Spring Mvc, Hibernate, Jquery, And Bootstrap , 9789355424686 Painter Functional Programming With C# , Bks561666 Karegowdaag Fundamentals Of C And Data Structures , 9788173716126 Horowitz Fundamentals Of Computer Algorithms 2Ed , Bks655202 Rajaraman Fundamentals Of Computers 6Ed , 9781032786001 Wagh Manisha Fundamentals Of Data Science , Bks662063 Horowitz Fundamentals Of Data Structures In C 2Ed , 9789355420121 Buduma Fundamentals Of Deep Learning 2Ed : Designing Next Generation Machine Intelligence Algorithms , 9789360531027 Lambert Fundamentals Of Python First Programs , 9789355428301 Jim Fuzzy Data Matching With Sql , 9789332549425 George Klir Bo Yuan Fuzzy Sets And Fuzzy Logic Theory And Application , 9789386052865 John R Larsen Get Programming With Javascript , 9789353506261 Nelson Guide To Computer Forensics & Investigation , 9789355424181 Kofler Hacking And Security The Comprehensive Guide To Penetration Testing And Cybersecurity , 9788126577040 Kevin Beaver Hacking For Dummies 6Ed , 9788126550517 Paul Hadoop For Dummies , 9788177228137 Chuck Lam Hadoop In Action , 9789355422415 Garcia Hands On Selenium Webdriver With Java A Deep Dive Into The Development Of End To End Tests ( Covers Selenium 4 ) , 9789355420701 Gandhi Head First Git A Learners Guide To Understanding Git From The Inside Out , 9789354240027 Motwani Hr Analytics Practical Approach Using Python , 9781032605197 Anne Implementing Cybersecurity , 9788126553051 Kulkarni Information Theory & Coding , 9789352868599 Deitel Internet & World Wide Web How To Program , 9789388991018 Shriram Vasudevan Internet Of Things 2Ed , 9789354247842 Raja Rao Internet Of Things An Indian Adaptation Concepts , 9789390727384 Raj Kamal Internet Of Things-2Ed , 9781292364902 Paul,Deitel Intro To Python For Computer Engineering Science And Data Science , 9789351199373 Davy Cielen Introducing Data Science Big Data Machine Learning , 9788131703069 Charniak Introduction To Artificial Intellegence , 9789332551947 Patterson Introduction To Artificial Intelligence , 9789351073901 Sayood Introduction To Data Compression 5Ed , 9789354640506 Maheswari Introduction To Data Science : Practical Approach With R And Python , 9788131713921 Kamthane Introduction To Data Structures In C , 9781032983585Chapman & Hall Introduction To Financial Derivatives With Python , 9789351194736 Surya Introduction To Information Security & Cyberlaws , 9781108959742 Misra Introduction To Iot , 9789357055048 Liang Introduction To Java Programming And Data Structures , 9781307918618 Martin Introduction To Language And The Theory Of Computation , 9781009069533 Subodh Kumar Introduction To Parallel Programming , 9789357055284 Daniel Liang Introduction To Python Programming And Data Structures 3Ed , 9788126550548 Jesse Feiler Ios App Development For Dummies , 9789386873743 Hanes Iot Fundamentals , 9789351197430 Urma Fusco Java 8 In Action , 9789351198468 Editorial Services Java 8 In Simple Steps , 9789351197584 Editorial Services Java 8 Programming Black Book , Bks642061 Barry Burd Java For Dummies 7Ed , 9789360538200 Farrell Java Programming , 9781032941462 Gans Javascript For Data Science , 9789355422729 Ackerman Javascript The Comprehensive Guide , 9781009211918 Sarma Joy With Java , 9789355421074 Jacques Jump Start Vue.Js 2Ed Build Your Own Sophisticated Web Apps , 9789355429773 Skoulikari Learning Git , 9789355425331 Bodner Learning Go 2Ed An Idiomatic Approach To Real World Go Programming , 9789355424440 Loy Learning Java 6Ed , 9789355429803 Osmani Learning Javascript Design Patterns 2Ed , 9789355427304 Andersson Learning Microsoft Azure , 9789355422507 Arnold Learning Microsoft Power Bi Transforming , 9789355422934 Hausenblas Learning Modern Linux A Handbook For The Cloud Native Practitioner , 9789351198147 Allen Downey Learning Python , 9789352132560 Swartz Learning Scala , 9789355428110 Kofler Linux The Comprehensive Guide , 9781316506110 Peter Flach Machine Learning , 9788126578511 Anuradha Machine Learning , 9781032937922 Mohammed Machine Learning Algorithms And Applications , 9781032746203 Geetha Sendhilkumar Machine Learning Concepts Techniques And Applications , 9781032707136 Gupta Brij B Machine Learning For Computer & Cyber Securitypb , 9781032941202 Agarwal Machine Learning For Healthcare Handling And Managing Data , 9781032937328 Tsai Machine Learning For Knowledge Discovery With R Methodologies For Modeling Inference And Prediction , 9789391540463 Rao Machine Learning In Data Science Using Python , 9789354246111 Kumar Rahul Machine Learning Using R , 9781009170246 Bhatia Machine Learning With Python , 9789355429292 White Making Embedded Systems 2Ed , 9789355422088 Gough Mastering Api Architecture : Design Operate And Evolve Api Based Systems , 9789355329509 Buyya Mastering Cloud Computing 2Ne Ed , 9789357462952 Seema Mastering Data Visualization Using Tableau , 9789383635818 Satyanarayana Mathematical Foundation Of Computer Science , 9788119847884 Avinash Valiramani Microsoft Azure Networking : The Definitive Guide , 9788119847372 Paul Mcfedries Microsoft Excel Formulas And Functions , 9788119847006 Tracy Syrstad Microsoft Excel Vba And Macros , 9788119847280 Sharp John Microsoft Visual C# Step By Step , 9781009566872 Jure Leskovec Rajaraman Mining Of Massive Datasets, 3Ed , 9788131731666 Garg Mobile Computing , 9789361595134 Tanenbaum Modern Operating Systems5th Ed , 9789355421685 Smirnova Mysql Cookbook 4Ed , 9789357462389 Bhattacharya Natural Language Processing , 9789353433123 Van Valkenburg/ Rathode Network Analysis Revised 3Ed , 9789355423900 Oswalt Network Programmability And Automation 2Ed , 9788196874339 Charlie Kaufman Network Security : Private Communication In A Public World , 9781259006166 Kumar Neural Networks , Bks660656 Rajasekaran & Pai Neural Networks , Fuzzy Sys .& Evolutionary Algor 2Ed , 9789332570313 Haykin Neural Networks And Learning Machines , 9789332549883 Jang Sun Mizutani Neuro Fuzzy And Soft Computing , 9789386052049 Young Node.Js In Action, 2Ed , 9789355422712 Buckler Nodejs Novice To Ninjathe Ultimate Guide To , 9788126516582 Shukla Object Oriented Programming In C++ , 9788131722824 Lafore Object Oriented Programming In C++ 4Ed , 9789389949186 Balagurusamy Object Oriented Programming With C++ 8Th Edn , 9789386858962 Tripti Paul Object-Oriented Programming Using Ja , 9789389552300 Barnes Objects First With Java : A Practical , 9781009349185 Rahul Vaze Online Algorithms , 9789357460569 Silberschatz Operating System Concepts 10 Th Ed , 9789332550513 Tanenbaum Woodhull Operating Systems Design And Implementation , 9789354437892 Panneerselvam Operations Research , 9789352865277 Hamdy Taha Operations Research :An Introduction-10Th Ed , 9789389538779 Hubbard Outline Of Programming With Java , 9781032850702 Vivek Kale Parallel Computing Architectures And Apis , 9789354244391 Richard Duda Peter Hard Pattern Recognition 2Ed , 9789355421067 Butler Phpmysql Novice To Ninja 7Ed , 9788126576005 Blum Php,Mysql & Javascript All-In-One For Dummies , 9789351194378 Nina Practical Data Science With R , 9789390820658 Bhattacharyya Practical Handbook Of Machine Learning , 9781493988280 Burnstein Practical Software Tesing , 9788126567935 Anasse Bari Predictive Analytics For Dummies , 9788126577132 Sivanandam Principles Of Soft Computing 3Ed , 9789390113026 Kamthane Programming And Problem Solving With Python 2Ed , 9789388818735 Yadav Rajiv Khanna Programming For Problem Solving Using C , 9788126519927 Wiley Editorial Programming For Problem Solving, As Per Aicte , 9789355326720 Balagurusamy Programming In Ansi C 9Ed , 9780198097402 Harsh Bhasin Programming In C# , 9788126562008 Butow Programming Interviews For Dummies , 9780198083962 Trivedi Programming With Ansi C++ , 9789360537753 Mcmullen Programming With C++ , 9789355325891 Balagurusamy Programming With Java 7Ed , 9789360534783 Mcmullen Programming With Python , 9788131711347 Bratko Prolog : Programming For Aritificial Intelligence, 3Ed , 9788197402555 Muthu Python And Data Science , 9789357465304 S. Horstmann Python Foe Everyone, 3Ed , 9788126524938 Massaron Python For Data Science For Dummies 2Ed , 9781041000822 Rakesh Nayak Python For Engineers And Scientists Con & App , 9789354973765 Reema Thareja Python Programming , 9789386668004 Dawson Python Programming For The Absolute Beginner , 9789352835102 Murali Mohan Python With Machine Learning , 9781032983738 Helmut Bez Quantum Computation , 9789352604555 Rakshit R For Beginners , 9789355429827 Wickham R For Data Science 2Ed , 9789386873521 Lander R For Everyone : Advanced Analytics And Graphics , 9781032940274 Harrison R For Health Data Science , 9789351198079 Kabacoff R In Action , 9789355423771 Monk Raspberry Cookbook 4Ed - Software And Hardware Problems & Solutions , 9781032785912 Chris Roda Real Time Visual Effects For The Technical Artist , 9789354641336 Acharya Reimagining Data Visualization Using Python , 9788132202271 Dzeroski Sasd Relational Data Mining , 9781041000631 Subhankar Das Search Engine Optimization And Marketing , 9781009284332 Deepak Search Methods In Artificial Intelligence , 9788126564064 Kambhampaty Service-Oriented Architecture & Microservices Architecture, 3Ed : For Enterprise, Cloud, Big Data And Mobile , 9781107512818 Reza Zafarani Social Media Mining , 9789354247835 Tanmoy Chakraborty Social Network Analysis , 9788122423600 Aggarwal Software Engineering 3Ed , 9789355325044 Pressman Software Engineering 9Th Ed , 9789390555475 Suman Software Engineering Concepts , 9789332582699 Lan Sommerville Software Engineering, 10/Ed , 9781107652781 Singh Software Testing , 9788177581218 Desikan Software Testing : Principles & Practice , Bks642975 Chauhansoftware Testing 2Ed , 9789355422057 Korotkevitch Sql Server Advanced Troubleshooting And Performance Tunning Best Practices And Techniques , 9789390466078 Molly Monsey Tableau For Dummies , 9788177584813 Triebel The 8088 & 8086 Microprocessors : Programming , Interfacing, Software, Hardware & Applications 4Ed , 9789361591471 Omar Santos The Ai Revolution In Networking Cybersecurity And Emerging Technologies , 9789332549449 Brian Kernighan The C Programming Language , 9789356060135 Stroustrup The C++ Programming Language-4Ed , 9781498770354 Honbo The Internet Of Things In The Cloud , 9788120329683 Mishra Theoryof Computer Science , 9788126533114 Mahesh Theory Of Computation A Problem-Solving Approach , 9789357460392 Gookin Troubleshooting & Maintaining Ps All In One For Dummies , 9781107512825 Shai Shalev Understanding Machine Learning From Theory To Algorithms , 9788131521564 Flynn Understanding Operating System , 9789355425027 Franz Usability And User Experience Design , 9789355735577 Albright Vba Modelers : Developing Decision Sup , 9780367241773 John Hattie Visible Learning Into Action: International Case Studies Of Impact , 9789361595646 Lindy Ryan Visual Analytics Fundamentals , 9788131717158 Jackson Web Technologies , 9788177229974Kognt Web Technologieshtml Javascript Php Java Jsp Asp .Ne , 9789353432751 Michael Artin Algebra2nd Edition , 9788119896554 Carlberg Bayesian Analysis With Excel And R , 9789388005364 Veerarajan Complex Analysis , 9781493991099 Wells Differential Analysis On Complex Manifolds, 3Ed , 9789388005234 Veerarajan Differential Calculus , 9789388005371 Arumugam Differential Equations And Applications , 9789353433055 Ralph Grimaldi Discrete And Combinatorial Mathematics , 9789388005159 Veerarajan Fourier Series And Integral Transforms , 9781009243902 Prahlad Vaidyanathan Functional Analysis , Bks361487 Sankara Intro To Partial Differential Equations , 9789391549893 Ubaidullah Linear Algebra , 9789332550070 Hoffman Funze Linear Algebra , 9781032983615 Lina Oliveira Linear Algebra , 9789357059688 Lay Linear Algebraand Its Applications 5Th Ed , 9788131530245 Poole Linear Algebra A Modern Introduction , 9789388005111 Arumugam Modern Analysis , 9789353163815 Veerarajan Numerical Methods , 9789352865277 Hamdy Taha Operations Research :An Introduction-10Th Ed , 9789395161404 Prasad Partial Differential Equations , 9789356062733 Vijayakumari Statistics And Numerical Methods 10Ed , 9789385462603 Mishra Theory Of Tranforms With Applications , 9788119896608 Hass Thomas Calculus 15Ed , Bks294199 Ghoshal Atomic Physics (Modern Physics) , 9788131758915 Goldstein Classical Mechaincs , 9781032983608 Carolina C Llie Classical Mechanics Problems And Solutions , 9781944660987 Parames Concepts In Practice Physice: A Concise Introduction To The Standard Model , 9789352606955 Malik Engineering Physics , 9789386873316 Sharma Engineering Physics , 9781009338424 Sengupta Introduction To Quantum Mechanics , 9780521139878 Riley Mathematical Methods For Physics And Engineering 3/E , 9789354244681 Krane Modern Physics 4Ed An Indian Adaptation , 9788126552566 Walker Halliday Principles Of Physics 10Th Ed Isv , 9789357460835 David Halliday Principles Of Physics Extended 12 Ed , 9788131708392 Bransden Quantum Mechanics , 9788120336353 Aruldhas Quantum Mechanics 2Ed , 9789354640773 Zettili Quantum Mechanics Concepts And Applications , 9781009446556 Deshmukh Quantum Mechanics: Formalism, Methodologies And Applications , 9789380156248 Basu Solid State Engineering Physics , 9781032791456 Roopchand Activated Carbon Adsorption , 9788173713859 Krupadanam Analytical Chemistry , 9789388991094 Christian Analytical Chemistry An Indian Adaption , 9789390211562 Pasada Rao Basic Quantum Chemistry P.B , 9781032728971 Depan D. Biodegradable Polymeric Nanocomposites: Advances In Biomedical Applications , 9788194726364 Albert Cotton Chemical Applications Of Group Theory , 9789389974935 Sarka Fundamentals Of Analytical Chemisty P.B , 9788178000619 Anjaneyulu Introduction To Environmental Science , 9789381075920 Braun Introduction To Instrumental Analysis 2/Ed , 9781032512020 K M Mackay,R M Mackay Introduction To Modern Inorganic Chemistry 6 , 9789354240201 Charles Poole Frank Introduction To Nanoscience And Nanotechnology , 9781138096882 Mark Schulz Nanoengineering Of Strucatural Functional And Smart Materials , 9788187134114 Ghoshal Numerical Problems On Physical Chemistry , 9789387593848 Alagarsamy Organic Chemistry: A Comprehensive Approach (Pb) , 9789389802085 Kalsi Organic Reactions And Their Mechanisms 5/Ed , 9788194897439 Lal Physical Chemistry , 9788178002019 Mukkanti Practical Engineering Chemistry , 9789393796004 Unique 12.07.2 Upsc Cse Main Answer Writing Skills - Tp , 9788119361052 Unique 13 Years Upsc Civil Services General Studies Csat Previous Papers - Ii , 9788119361281 Singh 29 Years Upsc Previous Papers , 9780367237356 R L Trask A Dictionary Of Phonetics And Phonology , 9788119348015 Bk Pub A House Of Pomegranates , 9781032296425T Hawkes Alternative Shakespeares (Vol-2) , 9789387265523 Bk Pub An Enemy Of The People , 9789390113644 Ponam Dalal Dahiya Ancient And Medieval India 2Nd Edn , 9788126569502 Wiley Aptipedia Aptitude Encyclopedia 2 Ed , 9789355320414 Vinay Art And Culture Q.B.--3Ed , 9789355324832 Prashant Jagtap Capf Paper 1 General Studies , 9789357052719 Thorpe Concise General Knowledge Manual 2024 , 9789387572324 Edgar Thorpe Course In Mental Ability And Quantitatine Aptitude , 9781032937199 Plucker Creativity And Innovation Theory Research And Practice 2/E , 9789357059343 Sinha Data Interpretation For Cat , 9789355424457 Das Entrepreneurial Designs For Start Ups , 9788119361144 Unique Ethics Made Easy , 9789395259750 Unique Excellence In Governance , 9781032296395 R Jackson Fantasy , 9781032296876 T Bennett Formalism And Marxism , 9788119361267 Unique Fundamentals Of Ethics , 9789356814257 Cl Educate Gate 2025 - Computer Science And Information Technology - Guide By Gkp , 9789356817593 C L Educate Gate 2025 Civil Engineering - Guide By Gkp , 9789356815728 Gkp Gate 2025 Electrical Engineering Guide , 9789356819306 Gkp Gate 2025 Electronics And Communication Eng.Guide , 9789356813885 Cl Educate Gate 2025 General Aptitude - Guide Gkp450 , 9789356814073 Kuldeep Chaudhary Gate 2025 Mathematics , 9789356817746 Gkp Gate 2025 Mechanical Engineering Guide , 9789393796479 Unique General English , 9789357052672 Thorpe General Knowledge Manual 202422/Ed , 9788119361724 Unique General Knowledge Manual 2025 , 9789356819474 Sasikumar General Studies Csat Paper Ii , 9789355327796 Mhe General Studies Paper - I ( 2025 ) , 9789355329929 Mhe General Studies Paper - Ii For Civil Services Preliminary Examination , 9789391061982 Gkp General Studies Paper - Ii For Upsc Civil Service , 9789389573961 Majid Husain Arora General Studies Paper I In 100 Days , 9789385507359 Jonathan Swift Gullivers Travels , 9789355327024 Arun Sharma How To Prepare For Quantitative Aptitude11th Edn , 9788119896035 Pearson Ibps Clerk Mains Mock Tests , 9788119896660 Pearson Ibps Clerk Pre Mock Tests , 9788119896127 Pearson Ibps Po Mains Mock Test , 9788119896059 Pearson Ibps Po Pre Mock Tests , 9789361593840 Agrawal Indian Economy 2Nd Ed , 9789390219179 Reddy Indian History 3E , 9788119361892 Singh Indian Polity Mind Maps 3Rd Ed , 9789355320100 Vinay Indian Polity Q.B-4Ed , 9788119361151 Unique Internal Security , 9789395259743 Unique International Relation Diplomacy Primer , 9789357059336 Sinha Logical Reasoning For Cat , 9789391968281 Bk Pub Lost Horizon , 9781032906546 Catherine Stothart Motivation The Ultimate Guide To Leading Your Team , 9789391968946 Bk Pub My India , 9781032511580 C Dionne,P Kapadia Native Shakespeares , 9789355015075 Aggarwal Objective General English , 9781032296449 A Loomba Post Colonial Shakespeares , 9789355321725 Laxmikanth Public Administration-2Ed , 9788126549306 Anand Quantitaive Aptitude , 9789358705010 Aggarwal Quantitative Aptitude , 9788126559008 Tcy Online Reasoning Ability And Quantitative Aptitude , 9789387265561 Daniel Defoe Robinson Crusoe , 9788119896349 Pearson Sbi Clerk Main Mock Tests , 9788119896745 Pearson Sbi Clerk Pre Mock Tests , 9788119896684 Pearson Sbi Po Mains Mock Tests , 9788119896363 Pearson Sbi Po Pre Mock Tests , 9789357055772 Naveen Kumar Science And Technology , 9789355320025 Vinay Science And Technology Q.B. 4Ed , 9789395259965 Unique Secret History Of Selections Of Supreme Court Judges , 9789391968588 Shakespeare Sonnets And A Lovers Complaint , 9789391968939 Bk Pub Stories From Tagore , 9789395259477 Unique Syllabus 2023 With Planning Suggestions & Strategies , 9781032886206 Vallikannan Tamil Prose After Bharathi Pb , 9781032296388 S Cohan Telling Stories , 9789395515917 Hardy Tess Of The D Urbervilles , 9789391549237 Anantharani The Chapter On Wealth , 9789385507519 Fitzgerald The Great Gatsby , 9788119348039 Bk Pub The Importance Of Being Earnest , 9789393796417 Verma The Indian Economy , 9789391968465 Kipling The Jungle Book , 9789383635511 Rao The Noble Laureates And Their Legacies Set Of 2 Vols , 9788119376056 Bunyan The Pilgrimsprogress , 9789391968663 Gibran The Prophet , 9788119348909 Bk Pub The Rivals , 9788119348862 Bk Pub The Sea Wolf , 9789385507441 Bk Pub The Woodlanders , 9789385507557 Jerome Three Men In A Boat , 9789357461764 Dipak Kumar Training And Development Theories And Applications 2Ed , 9789356813229 Gkp Upsc 2024 General Studies Paper-2(Csat) 21 Practice Papers , 9789356813113 Gkp Upsc-2024 General Studies Paper -1- 21 Practice Papers , 9789357052825 Sinha Verbal Ability And Reading Comprehension For Cat 5/Ed , 9788126554294 Anand Lalit Singh Verbal Ability And Reasoning For Competitive Examinations , 9788119361175 Pavaneet Singh 45 Years Upsc Civil Srvices Previous Paper , 9789390395514 Wiley Wiley Acing The Interviews
Contract Date: Nov 04, 2025 Contract Value : 6.81 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
43.
Public Administrative Department #8200016 AOC
Tender For District Siddharth Nagar Mandal Stariya Office Building Construction Work - CIVIL WORK Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1 2 Sand Filling-Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27) 3 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 4 Providing & injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface ifplinth junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc., complete (plinth area of the building at ground floor only shall be measured as per IS-6313 Part II 1981)Aldrine emulisifiable concentrate or any other approved material such as Hepthachlor or Chlordance will be used. The rate of application of chemical emulsion shall be as follows- (I) Treatment for masonary & foundation 5 Ltr. per Sqm. (II) Back fill in immediate contact with foundation 7.5 Ltr.per Sqm. (III) Treatment of top surface of plinth filling 5 Ltr.perSqm. (IV) Treatment ofsoil along external peri meter of building 7.50 Ltr. per Sqm. (V) Treatment of soil under apron along external perimeter 5 Ltr. per Sqm. PWD SORS.I.No. 1 Chapter 8 5 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 400 mm dia piles DSR 20.3.2 6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.1.1 Pile Cap 7 Column 8 Plinth 9 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2.1 Lintel 10 Slab 11 Beam 12 Column 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. Upto plinth DSR 5.22.6 & 14 Above plinth DSR 5.22.6 A.6 15 Add for using extra cement in the items of design mix over and above the specified cement content therein. DSR 5.35 16 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. DSR 22.5 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.1.2 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.4.2) 19 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) (DSR-6.13.2) 20 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (DSR-4.13) 21 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies,erraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1 ) 22 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Providing & fixing of hold fast for chaukhatsof doors and windows. DSR-10.31 23 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to steel window by welding (Window Grill) DSR-9.48 24 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Providing & fixing of hold fast for chaukhatsof doors and windows. DSR-10.31 25 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete (Tie Rod) DSR-10.31 26 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Z-Section Window)DSR-10.2 27 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides DSR 10.29.2 28 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panesDSR 10.30.1 29 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screwsDSR 9.21.1 30 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) DSR 9.22.1 31 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (300x16mm) DSR 9.62.1 32 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (250x10mm) DSR 9.63.1 33 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm) DSR 9.66.1 34 Providing and fixing in position collapsible steel shutter with vertical channels 20x10x2mm and braeed with flat iron diagonals 20x5mm size with top and bottom rail of iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangements, stopper, handles including applying a priming coat of approved steel primer. (DSR 10.3) 35 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) (Below GL.) (DSR-13.5.1) 36 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)DSR-13.5.2 37 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR-13.4.2 38 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm [DSR-11.41.2] 39 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm DSR- 11.46.2 40 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 41 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31 42 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm Granite stone slab of colour black, Cherry/Ruby red DSR8.2.2.2 43 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick DSR 11.26.1 44 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cementDSR 11.20.1 45 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). D.S.R. 10.28 [DSR-10.28] 46 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -: 1:1.5:3 (1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) DSR - 4.1.2 47 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and Manufacture DSR 13.62.1 48 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. DSR 13.46.1 49 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litreDSR 13.41+13.41.1 50 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. 13.80 51 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. DSR 4.17 52 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x800 and 0.5 mm thick with 25 mm height, made of G | sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.D.S.R. 12.54.2 53 Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concreteDSR 5.9.1 54 Centering and shuttering including strutting, propping etc. and removal of form: in Suspended floors, roofs, landings, balconies and access platform DSR 5.9.3 55 Centering and shuttering including strutting, propping etc. and removal of form: in Lintels, beams, plinth beams, girders, bressumers and cantileversDSR 5.9.5 56 Centering and shuttering including strutting, propping etc. and removal of form: in Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 57 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter [DSR-12.41.2] 58 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm Bend 87.5° [DSR-12.42.5.2] 59 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm [DSR-12.43.2] 60 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [DSR-12.22] 61 EXPANSION JOINTS Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturers pre-engineered self- centering arrangement that freely rotates / moves in all directions.The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap (DSR 5.44.1) 62 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap (DSR 5.45.1) 63 SURFACE DRAIN Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.DSR-2.8.1 64 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR-4.1.8 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) DSR -6.1.1 66 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregateDSR 11.3.1 67 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) DSR-13.5.1 68 SANITARY WORK SANITARY INSTALLATIONS & C.P FITTINGSProviding and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests DSR 17.1.1 69 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid DSR17.2.1 70 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps DSR 17.7.1 71 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe32 mm diaDSR 17.28.1.1 72 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 73 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern. DSR 17.5.1 74 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade DSR 8.10.2 75 Providing and fixingPTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms DSR 17.70.2 76 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. DSR 17.71 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. DSR 17.73.2 78 CP Brass fittings Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal boreDSR 18.21.2.1 79 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal bore DSR 18.49.1 80 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore DSR 18.51.1 81 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore DSR 18.53.1 82 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 100 mm diameterDSR 18.22.1 83 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore DSR 18.52.1 84 PVC PIPES & FITTINGS AND RAIN WATER PIPES Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm DSR 12.43.2 85 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design (embedded in the flooring / ground) 100 /90 mm diaDSR DSR no.19.2.1 86 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter DSR 12.41.2 87 Providing and fixing on wall face unplasticised PVC moulded fittings/acces.ies for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm BendDSR 12.42.5.2 88 Providing and fixing on wall face unplasticised PVC moulded fittings/acces.ies for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion Shoe (Plain) 110 mm Shoe DSR 12.42.6.2 89 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. DSR 12.44 90 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mmDSR 12.43.2 91 INTERNAL & EXTERNAL WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes DSR 18.8.2 92 25mm dia nominal outer dia pipesDSR 18.8.3 93 32mm dia nominal outer dia pipesDSR 18.8.4 94 Providing and fixingGI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). Internal work-Exposed on wall 25mm dia nominal bore DSR 18.10.3 95 32mm dia nominal bore DSR 18.10.4 96 40mm dia nominal bore DSR 18.10.5 97 50mm dia nominal boreDSR18.10.6 98 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 25mm dia nominal bore DSR 18.46.3 99 32mm dia nominal bore DSR 18.46.4 100 40mm dia nominal bore DSR 18.46.5 101 50mm dia nominal bore DSR 18.46.6 102 Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore DSR 18.17.1 103 32mm dia nominal bore DSR 18.17.2 104 40mm dia nominal bore DSR 17.17.3 105 50mm dia nominal bore DSR 18.17.4 106 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters DSR 18.48 107 SEWERAGE SYSTEMExcavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. DSR 2.10.1.2 108 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100mm diameter DSR 19.1.1 109 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe DSR 19.2.1 110 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. S.W.Pipes DSR 19.6.2 111 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. SWPipes DSR 19.3.2 112 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 DSR 19.4.2.2 113 Supplying and fixing C.I.cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 Kg. DSR 19.20 114 Providing and fixing 100 mm sand cast Iron grating for gully trap. DSR 17.29 115 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line DSR 19.7.1.1 116 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Extra for depth for manholes:Size 90x80cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.8.1.1 117 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar DSR 19.15.1 118 EXTERNAL SEWERAGEConstructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 DSR 18.33.1 119 SEPTIC TANK & SOAK PIT Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. From 0.00 mt to 1.50 mt & 1.50mt to 3.0 mt DSR-2.8.1 120 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR (DSR-4.1.8) 121 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (M-20) (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR-5.3) 122 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 123 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.A.6 124 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). DSR-11.3.1 125 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) [DSR13.5.1] 126 Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 [DSR-17.35.2.1] 127 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) [DSR 19.15.1] 128 Making soak-pit 2.5 m. diameter and 3 m. deep with 45 x 45cm dry brick honey comb shaft with F.P.S bricksandSW drain pipe completeasper standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.32.1 129 ELECTRICAL WORK Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A DSR 1.10.3 130 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Power plug wiring in PVC conduit (4x4 sq.mm.) DSR 1.12 131 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR 1.14.1 132 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR 1.14.2 133 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.14.3 134 2 X 6 sq. mm + 1 X 6 sq. mm earth wire DSR 1.14.4 135 2 X 10 sq. mm + 1 X 6 sq. mm earth wire DSR 1.14.5 136 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 1.5 sq. mmDSR 1.17.3 137 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 250 mm X 300 mm X 60 mm deep DSR 1.22.15 138 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch DSR 1.24.1 139 15/16 A switch DSR 1.24.3 140 3 pin 5/6 A socket outlet DSR 1.24.4 141 6 pin 15/16 A socket outlet DSR 1.24.5 142 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 1.25 143 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 1.26 144 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) DSR 1.27.6 145 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR 1.31 146 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 1.32 147 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. DSR 1.33 148 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. DSR 1.57 149 Supplying and fixing PVC batten/ angle holder including connections etc. as required. DSR 1.58 150 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door DSR 2.5.1 151 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole DSR 2.10.1 152 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required DSR 2.11 153 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2.21 154 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 155 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm DSR 7.1.2 156 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 7.7.2 157 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. DSR 19.1 158 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 63 Amp Four Pole DSR 2023 10.18 159 SUB HEAD (II) :- (NON SECHDULE ITEMS) Supplying and fixing of 63 Amp Four Pole MCB (10 KA) C CURVE SOR 1020 (A) 160 Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. 70.0 sq Mm*3.50 core.SOR 501 (M) 161 Supply and projection of factrory and wired metal wired metal clad dust and vermin proof mountingn. M.S channel Base with bottan and top cable entires Electrical contral panel with Tpn MCCBs(four pole 36Ka with thermal magnatic release)Switches complete and insturment chamber etc. complete in all respects. The instrument chamber shall be separate and shall complate of flush type digital metering system for phase to phase voltage. current and other paraments (Kva.P.f.K.W etc.)in each phase with toche type selector switch for diffrent reading instruments fuses current transformer etc. the panel Board shall have suitable capacity electrolytic aluminum busbars as per is 8623 or above insulated with heat shrink sleeving and mounted on the sides. the MCCBS shall be completed withsuitable cable end boxes. Compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as Amp and above well be provided with Ammetre. The panel board shall be fabricated with CRCA sheet with Ammetre. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6MM /2MM cubicle type switch shall be L/T or Schnieder of equvalent make. incoming 400 AMP , TPN-1 No.Outgoing 200 Amp. TPN-1 Nos, 100 Amp. TPN-2 Nos. & 63 Amp. TPN-1 Nos. CAT B. Cubicle Type SOR 804 C (ii) 162 Supply and fixing of 16 gauge MS durm with louvers duly painted including making hole in the wall for exhaust fan and finishing property complete in all respects. SOR 1122 163 Supply and fixing of recess / surface mounting round 15 to 18 watt cut out min 150 mm, height min 40 mm, LED down lighter having with heat sink, diffuser die cast aluminium housing with heat sink, diffuser/reflector and driver set, suitable for 24 Hr. continuous operation, complete in all respect. 100 lm/W, PF>0.95, THD<10% at full load, CRI>80, with 3 years warranty. SOR 1403 Cat AAA 164 Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextendedheat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. SOR 1406 Cat AAA 165 Supply and fixing of LED tube light with batten suitable for up 1 x 22 watt LED tube light fitting including tube on surface complete in all respect CAT - AAA SOR 1413 166 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 watt. Confirming to IP 65 protection complete in all respect. SOR 1453 Cat AAA 167 Supply and fixing of 200 Amp four pole change over switch on 50 mm x 50 mm x 6 mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of engineer in charge. SOR 379 168 S&L of 1800 mm x 900 mm x 12 mm thick chequred rubber matting of tested quality SOR 1136 169 Supplyand burring of Safe Earthing Electrode T-19 ( Hot Dip Galvanised) , Length up to 3000 mm , Outer GI pipe of 16 SWG and inner with crystalline conductive misture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivty with good mixture of retaining capacity and one earthing lead of 25mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D. & C.P.R.I. Certified. SOR 725 B 170 FIRE FIGHTING SYSTEM Supplying, installation, testing & commissioning of main control and indicating panel made out SWG MS sheet to accommodate the following items duly powder coatedinapprovedcolourwithlouversforventilation, locking arrangement, audio and visual indication for fire alarmandpublicaddresssystem,monitoringsystem includingconnections,interconnectionsetccomplete as required. 6 Zone panel for fire alarm system 100 Watt amplifier racks suitable for operation on 230V AC/24VDCsupplyconfirmingtoIEC-268-3complete withallaccessoriesasrequired-2Nos.(onetoactas standby) TalkbackmasterstationwithLEDPTT(presstotalk) push button for operation on 230V AC/24 V DC supply confirming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. Annoucementcontroldesksuitableforselectionof differentzonesselectivelyandONALLCALLswitch with visual indication etc. complete as required-1set. Amplifier change over switch for inter changingamplified-1 No. Monitorpanelforloudspeakercompletewithoutput selector, ON/OFF switch,fuse,visual indications etc. complete as required-1 No. Gooseneck microphone with stand and ON/OFF switch 1 No. Main ON/OFF switch,fuse indication lamps, DC and AC voltmeters&ammeters,terminalblocksetc.Complete as required-1 set. 1 Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories includingproviding&fixingof2nos.12volt,30AH eachsealedmaintenancefreebateries-1set. DSR- 17.1.11 171 Supplying, installation, testing & commissioning of addressablemanualcallpointcompleteasrequired. DSR-17.2.14 172 Supplying,installation,testing& commisssioningof intelligent addressableprogrammable sounder complete as required.DSR-17.2.6 173 Supplying & laying of 2x1.5 sgqmm fire survival armoured cable, 600/1000V rated with annealed copperconductorhavingglassmicafirebarriertape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH innerbedding,steelwirearmouring&LSZHouter sheath complete as required. DSR-17.5.1 174 Supply andfixingandconcealingof20mm dia. 2mm thickPVCconduitpipewithISImarkembossedand withPVCaccessoriesconfirmingtoISNo.3419for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering withcementsandmortarfinishedtothelevelwith matchingcolourwashincludingcostofallmaterial labourandT&Petcrequiredforpropercompletionof theworkasperdirectionsandtothesatisfactionof Engineer in charge. PWD Elec -148(A) 175 Supply and fixing of CO2 type fire extinguisher 4.5 kg. capacity(ISIMarked) completewithinitialchargeand wallbracket,alongwithsupplyofallmaterialsand labour for proper completion of work.PWD Elec -1132 176 Supplyandfixingoffireextinguisher,ABCType6.00 kg.capacity(ISIMarked)completewithinitialcharge and wall bracket, along with supply of all materials and labourforpropercompletionofwork. PWDElec- 1131(A) 177 WET RISER SYSTEM Providing,laying,testing&commissioningofCclass heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mmDSR-18.7.7 178 80 mmDSR-18.7.6 179 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominalinternaldiawaterhosethermoplastic(Textile reinforced)type-2asperIS:12585.20mmnominal internaldia gun metalglobe valve& nozzle.Drumand bracketsforfixingtheequipmetsonwall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. DSR-18.17.1 180 Supplyingandfixingsingleheadedinternalhydrant valvewithinstantaneousGunmetal/StainlessSteel couplingof63 mm diawith cast iron wheelISI marked conformingtoIS5290(Type-A)withblank Gunmetal/ StainlessSteelcapandchainasrequired: Single headed Stainless steel. DSR-18.9.1 181 Supplyingandfixing63mmdia,15mlongRRL hose pipewith63mmdiamaleandfemalecouplingsduly bound with Gl wire, rivets etc. conforming to IS 636 (type A) as required: Stainless Steel (Grade 304)DSR-18.16.2 182 Supplying&fixing 63mmdiagun metalshort branch pipe with 20mm nominalinternal diametersize nozzle conformingtoIS903suitableforinstantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304) DSR-18.18.2 183 Supplying& fixingof Firebrigade connection of cast iron body with gun metal male instantaneous inlet couplingcompletewithcapandchainasrequired.for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100mm dia MS Pipe.DSR-18.19.1 184 Supplying,installation,testingandcommissioningof electric driven terrace pump suitable for automatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump). Horizontal type, multistage,centrifugal,splitcasingpumpofcastiron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cageinductionmotorTEFCtypesuitableforoperation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type withClass-Finsulation,conformingtoIS-325.M.S. fabricated common base plate, coupling, coupling guard, foundationboltsetc.asrequired.Suitablecement concrete foundation duly plastered and with anti vibration pads. 450 Ipm at 35 m Head. DSR-18.4.2 185 Providing & fixing of pressure switch in M.S.pipe line including connection etc. as required. DSR-18.22 186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor havingXLPEinsulation,steelwirearmouring&FRLS outer sheath complete as required. DSR-17.5.2 187 Supplyingandlayingof aluminiumconductorPVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushionof75mmthicksandallaroundandprotected withburntbricksonsideandontop.Onsurfacethe cablerunshallbefixedonMSclampsetc.ofsuitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connectedwiththeearth conductorby clamps etc. Size 25 sq mm x 3-1/2core. PWD-501(J) 188 Providingandplacingonterrace(atallfloorlevels) polyethylenewaterstoragetank,IS:12701marked, with cover and suitable locking arrangement and making necessary holesforinlet,outletand overflowpipesbut without fittings and the base support for tank. DSR 18.48 189 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm diaDSR-18.11.5 190 80 mm dia DSR-18.11.4 191 Providing, installation, testing and commissioning of non returnvalveoffollowingsizesconfirmingtoIS:5312 completewithrubbergasket,Glbolts,nuts,washers etc.as required :100MM dia. DSR-18.14.5 192 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valveontopandflangedconnectiontoriser,drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with syntheticenamelpaintofapprovedshade asrequired. DSR-18.20 193 RAIN WATER HARVESTING RECHARGE PITSExcavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In all kind of soil upto 1.5m depth DSR-2.8.1 194 In all kind of soil upto 1.5m to 3.0m. Depth DSR-2.8.1 195 In all kind of soil upto 3.0m to 4.5m. Depth DSR-2.8.1 196 In all kind of soil upto 4.5 m to 6.0m. Depth DSR-2.8.1 197 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. (DSR-4.1.8) 198 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 199 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (M-20) (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (M-20) (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) DSR 5.1.2 200 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. DSR 5.22.6 201 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand (DSR-13.5.1) 202 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar DSR-19.15.1 203 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter DSR-19.19.2.2 204 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually.DSR 23.2.1.1 205 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia DSR-23.4.2 206 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. DSR-23.5 207 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.DSR-23.6 208 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. DSR-23.7 209 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. DSR-23.8 210 DRAINAGE NETWORK Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter DSR-2.10.1.2 211 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes DSR.19.6.2 212 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. DSR-19.3.2 213 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5 DSR-18.33.1 214 BOUNDARY WALL Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1 215 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 216 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles DSR 20.3.1 217 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.1.1 218 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cumDSR 5.33.2.1 219 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.4.2) 220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.4.2) 221 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. upto plinth DSR 5.22.6 222 above plinth DSR 5.22.A.6 223 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DSR-13.4.1 224 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 0.90 kg/10 Sqm. DSR 13.46.1 225 Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concreteDSR 5.9.1 226 Centering and shuttering including strutting, propping etc. and removal of formin Lintels, beams, plinth beams, girders, bressumers and cantileversDSR 5.9.5 227 Centering and shuttering including strutting, propping etc. and removal of form Columns, Pillars, Piers, Abutments, Posts and StrutsDSR 5.9.6 228 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR-10.31 229 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 230 GATE Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1 231 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 232 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 400 mm dia piles DSR 20.3.2 233 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR - 5.33.1.1 234 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2.1 235 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. upto plinth DSR 5.22.6 236 above plinth DSR 5.22. A.6 237 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DSR-13.4.1 238 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. DSR 13.46.1 239 Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concreteDSR 5.9.1 240 Centering and shuttering including strutting, propping etc. and removal of form: in Lintels, beams, plinth beams, girders, bressumers and cantileversDSR 5.9.5 241 Centering and shuttering including strutting, propping etc. and removal of form: in Columns, Pillars, Piers, Abutments, Posts and StrutsDSR 5.9.6 242 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.DSR 10.16.3 243 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 244 C.C. ROAD Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)DSR-6.1.1) 245 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)(DSR-4.1.10) 246 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all lead & lifts, spreading in uniform layers of specified thickness with motorgrader on prepared surface and compacting with vibratory power rollerto achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mmto 0.075 mm ) having CBR Value-25DSR 16.78.2 247 P/L of 125 micron polythene sheets as per Material rate M-104 (.S. ITEM) 248 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site,spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately Cement concrete prepared with batch mixing machine DSR 16.43.1 249 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to 18:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)DSR 16.45 250 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads /pavements allcomplete as per direction of the Engineer-in-Charge.DSR 16.46.1 251 EARTH FILLING Excavating. Supplying, stacking and filling of local earth (including roylaty) by mechhanical transport upto a lead of 5 km. also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation, Cumpusside development etc. complete for all lift. DSR 2.25A 252 Storm Drain (450 mm X 600 mm) Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1 253 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 254 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR -6.1.1) 255 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 256 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) (DSR-13.5.1) 257 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (M-20) (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) DSR 5.1.2 258 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.A 6 259 Submersible Pump Set Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia DSR 23.1.1.1 260 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (I) 110 mm nominal size dia DSR 23.3.1 261 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (I) 110 mm nominal size dia. DSR 23.4.1 262 Supplying, filling, spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. DSR 23.7 263 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. DSR 23.12 264 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :110 mm dia DSR 23.13.1 265 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 110 mm clamp. DSR 23.14.1 266 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 110 mm dia. DSR 23.15.1
Contract Date: Nov 04, 2025 Contract Value : 5.94 Crore
Government Departments No of Bidders 6
Uttar Pradesh View Result →
44.
Public Administrative Department #8034303 AOC
Construction And Development Of Working Women Hostel At Kanchanwadi Chhatrapati Sambhajinagar- 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) 2 Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means 3 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 4 Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical Means 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steelcentering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 6 Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. 7 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete 8 Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) 9 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 10 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 11 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 12 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 13 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 14 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 15 Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 17 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc.complete. 18 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 19 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints,watering and scaffolding etc. Complete 20 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 21 Providing and fixing precast R.C.C. frames of door/windows/ ventilators of c/s 125mm X 50mm with 2 bars of 8mm dia. Of steel as r/f . In half brick wall 22 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 23 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. 24 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) 25 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box. 26 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc 27 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete 28 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. 29 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 30 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 31 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 32 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or a directed etc. complete. 33 Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 34 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete 35 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity above 1000 to 20,000 litres 36 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 37 Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 38 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete 39 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 40 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. 41 Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete 42 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. 45 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 46 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete 47 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd A1/259) 48 Lift 0 to 1.5 M Cum 140.00 140.00 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-2/259) 49 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-4/259) 50 Providing ISI standard stoneware pipes including all taxes inspectin charges, railway freight, unloading, transoport, stacking,complete.150mm dia. SWG pipe 51 Louvering and jointing in proper grade, alignment standard stoneware pipes with cement joint 1:6 C.M. proportion including unloading, transoport, stacking, necessary excavation and jointing complete. 150mm dia. SWG pipe 52 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 53 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR.Item no. 35.21) 54 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) 55 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 56 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. 57 Transportation of surplus material from work site to any disposal place as directed by Er.incharge eith a lead of 5km including and stacking completed. 58 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. 59 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. 60 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi- strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surfaceand nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated,Hex head, self-drilling screw etc. complete. (weight of profile 61 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 year guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete 62 Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish 63 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 64 Providing, applying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealent, backer rods etc. overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre) 65 Providing and preparing kitchen otta up to 75 cm width, made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. 66 Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete 67 Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick (minimum) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings, fixtures, smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) 68 Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.One Number: As directed by Engineer- in-charge. 69 Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mm dia G.I. pipe ( Rezan/ concentiDeleted ire 0.75 mm dia ) with hot dip and G.I. coated hooks as per drawing supported on M.S. angle 50 x 50 x 6 mm at 2.5 mtr. c/c including fixing and fastening with wire, painting M.S. angles with one coat of red lead primer and two coat of oil paint etc. complete. 70 Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method ( excluding reinforcement) approved by Engineer-in-charge. 71 Single Bed @ 2025LX 1000DX 650HProviding and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm.Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side laminate 72 Bed Side Table @ 400LX 400DX 415HProviding and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding 73 Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required. 74 Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery 75 NOMAD Interactive Screen: Providing and Fixing NOMAD Interactive Screen with storage. Specification size : 1260L X 500D X 1800H. Prior approval of Engineer in charge in necessary. 76 Providing & Arrangemnt of MId Back, Normal SyncroMechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery. 77 Café Chrome 6 Seater Canteen tableSpecification : 1800L x 900D x 750H. Prelam Hydroshield Top with MS Understructure in Chrome finish 78 Tango Cafeteria Chair* Stackable Chairs* Without Arms* One Moulded Unbreakable Chair* Available Colors - White, Black, Green, Yellow, Red. 79 Double Bed (Compact 2 Nos.) Specification : 1980L X 900D X 450-750HMade inPrelam board with understorage 80 Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. 81 Sofa Set 3+1+1Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat 82 4 Seater Dining TableSpecification : 800L x 800D x 750H.Prelam Hydroshield Top 83 Stool for Lab and Class-IVProviding and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 84 Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 85 Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery. 86 Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. 87 Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. 88 Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 89 12 Seater Reading Table for Library @3600Lx1200Dx750HTProviding and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. 90 Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. 91 Library Area Table @ 1350Lx750Dx750HTProviding & Fixing of FREE STANDING TABLE @ 1350Lx750Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, BENT LEG to be CHROME FINISH as per drawing. 92 CHILDREN TRIANGLE TABLESize: 1300L x 1300LX1300L x 400H Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 93 CHILDREN CHAIR Size:400LX 400L Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 94 CHILDREN SHELF Size:2560LX 400D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support:End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 95 Executives Table @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing. 96 CHILDREN CRIB Size:1000LX 650D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 97 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 98 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 99 Supplying and erecting PVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX(1-2-11) 100 Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 101 Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 102 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 103 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 104 Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 105 Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 106 Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 107 Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 108 Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 109 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 110 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 111 Supplying and erecting modular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.(1-6-10) 112 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 113 Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.(1-6-23) 114 Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.(1-6-24) 115 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. 116 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. 117 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12module duly erected. 118 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 119 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 120 Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW(1-7-26) 121 Supplying and erectingLED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 122 Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 30 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 123 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 124 Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.(2-1-16) 125 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 126 Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt,CRI>80, CCT of 6500K and THD<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty.(2-1-22) 127 Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.(2-3-13) 128 Supplying and erecting Electronic type cordlesscallbell erected on T.W.board havingportablebellpush working on 9V D.C. battery and(effective range upto 45 meter) bell on 250 V A.C. supply.(2-3-15) 129 Supplying and erecting integrated LED Highbay Fitting70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 130 Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.2(-10-13) 131 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF(2-10-22) 132 Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 133 Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.(2-11-6) 134 Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC(3-3-9) 135 Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)(3-5-1) 136 Supplying, installing, testing and commissioning of3 kVA capacity online pure sine wave with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS(3-7-3) 137 Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-9) 138 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-6) 139 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-8) 140 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP(9-1-1) 141 Supplying, erectingandmarking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-2) 142 Supplying, erectingandmarking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-3) 143 Supplying, erectingandmarking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-10) 144 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 145 Supplying and erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB(5-4-1) 146 Supplying&erectingtriplepoleand neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB 147 Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), withdoor, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 148 Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW SWR/MCBDB(5-4-9) 149 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 150 Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 151 Supplying, Erecting and Commissioning of4 pole RCCB 40A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB(5-6-5) 152 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 153 Providing and erecting 4 Pole MCCB,100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB(5-5-1) 154 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 155 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 156 Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete.(6-1-1) 157 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 158 Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard(6-1-20) 159 Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB 160 Supplying and erecting panelmountingtypedigital ammeterhavingthreeandhalfdigitLEDdisplay, externalCToperated,calibratedfor suitable to operate on 500V, 0 to 1000Ahaving accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs andmounting hardware on provided panel complete with calibration certificate from manufacturer.(6-3-7) 161 Supplying and erecting panelmountingtypedigital voltmeterhavingthreeandhalfdigitLEDdisplay, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5,AC supplywithnecessaryPVCwireleadsandlugsand mountinghardwareonprovidedpanelcompletewith calibration certificate from manufacturer.(6-3-8) 162 Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panelmounting to measures and displayparameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I,kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software(6-3-19) 163 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. 164 Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on providedbox / panelwith necessary material, wiring & connections etc.(6-5-5) 165 Supplying and erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.(6-5-6) 166 Supplying and erecting 50 kVAr,3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 Vand having minimum overcurrent capacity of 1.8 In,peak inrush current capacity 300 Inand minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC 167 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 168 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 169 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-31) 170 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 171 Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete(1-6-15) 172 Supplying & erecting20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW 173 Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW 174 Supplying, erecting & commissioningMDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW 175 Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW 176 Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW(1-9-18) 177 Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of6 x 32 extensions suitable upto 96 extensions complete. 178 Supplying, Erecting and Commissioning ofpush button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.(1-9-29) 179 Supplying, Erecting and Commissioning ofIP telephone instrument as per specification complete.(1-9-30) 180 Supplying and erecting unbreakable concealed typemodular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-6-34) 181 Supplying and erecting 20m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. 182 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC(1-10-1) 183 Supplying and erecting LSZH armoured multimode Optical Fibre Cable with 24 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC 184 Supplying and fixing1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-17) 185 Supplying and fixing3 m UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-20) 186 Supplying, fixing, and configuring24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS(1-11-4) 187 Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL 188 Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.(1-12-1) 189 Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO 190 Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP 191 Supplying and fixing9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK(1-12-18) 192 Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension: 1020 x 846 x 1840 (mm), Input power: 6.02 kW, 400 V, 3 Ph, 50 Hz, Output power: 19.8 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, centrally controlled operation, operational noise level: 65 dBA with necessary accessories complete with 5 years ON-SITE warranty. 193 Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 5000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricatedwith 6 mm thick plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2 BSP forprovision toinstall6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. 194 Supplying,erecting, testing and commissioning of10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) havingminimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hzincoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V ACat each socket with 3.5TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mmduly RAL7035 Coated M.S, Erected oniron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification. 195 Supplyinganderecting Biometric Access Control System working on 230V A.C. supply with resetting arrangement complete erected 196 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 197 Supplying, fixing, and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS(5-3-25) 198 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 199 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-27) 200 Supplying and erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE(7-6-2) 201 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 202 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 203 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 204 Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 60 to 170 LPM discharge at 97 to 30 m head & discharge & delivery pipe of Size-40 mm diameter with a necessary H type clamps as per specification No. WP-SMP 205 Supplying and erecting minimum Three & above star rated submersiblepump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP(12-3-2) 206 Supplying and erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P.(12-4-2) 207 Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-8) 208 Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-9) 209 Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.(12-4-15) 210 Supplying and erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .(12-4-17) 211 Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(16-1-5) 212 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 213 Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.(16-5-6) 214 Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete.(16-5-18) 215 Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.(16-6-15) 216 Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.(16-6-21) 217 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 218 Supplying, installation, testing and commissioning extendable/non-extendable indoor type 11 kV, 630A,load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundations per specification no SW-HTS / LBS 219 Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982(6-1-16) 220 Supplying,erecting,testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation. 221 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 222 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 150 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 223 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 224 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 225 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 226 Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ(8-1-13) (11 mtr x 2 Pole =22) 227 Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.(8-3-17) 228 Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI 229 Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN 230 Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA 231 Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. 232 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9- 1-1) 233 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 234 Supplying, installing, testing & commissioning 3 phase,11/0.433 kV,50 Hz., 250 kVA, Mineral oil immersed and naturally cooledoutdoor type, Copper wound, without gas cushioning , hermetically Sealedtransformer, delta/star connected with additional neutral brought out on load side, temperature rise should not Exceed 45℃ by thermometer in oil and 50℃ by the resistance methodin winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 980 Watts at 50% load, 2930 Watts at 100%load as perIS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL 235 Supplying and erecting11 kV outdoor type gang operated airbreak,triple pole switch 400 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channels on providedcrossarmwithadequate length of C class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. 236 Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fusebarrelwithmetalfitting,fuse elementmounted onM.S.channel with working currentof15A capacity complete erected on provided cross arm. 237 Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG(10-6-18) 238 Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.(10-6-19) 239 Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD(10-6-20) 240 Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). 241 Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete.(10-6-22) 242 Providing pair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete.(10-6-23) 243 Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)(10-6-24) 244 Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV 245 Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544duly tested, with necessary test certificate from manufacturer.(10-6-28) 246 Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. 247 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 248 Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. 249 Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal,45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)(16-3-4) 250 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 251 MSEDCL Charges 252 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 253 Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.(5-11-19) 254 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 255 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 256 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 257 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspectoras per specification no. GEN-DG 258 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 259 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 260 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 261 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV(1-3-14) 262 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 263 Supplying and erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation.(5-2-5) 264 Supplying, erectingandmarking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-1) 265 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 266 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 267 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 268 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT(8-2-21) 269 Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 270 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 271 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 272 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 273 MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 274 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 275 Supplying, installation, testing and commissioning of booster fire pump[BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of7.5 kW or of suitable kW capacityfor manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP 276 Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP 277 Supplying and erectingG.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP 278 Supplying and erectingG.I. pipe‘C’ class ERW65 mm dia with necessary fittings complete asper specification no. FF-PP 279 Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP 280 Supplying and erecting G.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-6) 281 Supplying and erecting G.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-7) 282 Providing G.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-8) 283 Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system.(13-6-10) 284 Supplying and erecting 100 mm dia cast iron foot valve ball type/flap typewith strainer for negative suction complete asper specification no. FF-VL/FV(13-7-2) 285 Supplying and erecting 100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-14) 286 Supplying and erecting 150mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-15) 287 Supplyinganderecting200mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV 288 Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV(13-7-24) 289 Supplying and erecting 25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV(13-7-32) 290 Supplying and erecting stainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV(13-7-35) 291 Supplying and installingone piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000litres fitted with necessary accessories complete asper specification no. FF-FFA/PT(13-8-1) 292 Supplying and installingwall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV(13-8-2) 293 Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL(13-8-4) 294 Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ(13-8-8) 295 Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC(13-8-11) 296 Supplying and erecting 300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT(13-8-12) 297 Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV(13-8-13) 298 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG(13-8-14) 299 Supplying and erecting 12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS(13-8-15) 300 Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer diawith required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP(13-8-16) 301 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valveof size ( 400 x 400 x 400)mm or hose pipe boxof size (600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mmhaving front doors with viewing glass of size (200x150) mmandlockingarrangement with necessary fixingmaterialsuch as rubber biddingetc. dulypainted in post box red colour( Code 538 of IS 5)(13-8-18) 302 Supplying and erecting M.S./CRCA cabinet forhousing FireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6) andlocking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)(13-8-19) 303 Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½) dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. 304 Supplying, erecting, testing and commissioning ofvane type water flow detector75/80 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.(13-12-2) 305 Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.(13-15-1) 306 Supplying, installing, testing and commissioning ofmanual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP(13-9-7) 307 Supplying, installing, testing and commissioning ofhooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR(13-9-8) 308 Supplying, installing, testing and commissioning ofFRLSXLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU(13-9-10) 309 Supplying, installing, testing and commissioning of2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP(13-9-14) 310 Supplying, erecting, testing and commissioning of120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR(13-11-1) 311 Supplying, erecting, testing and commissioning of15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC(13-11-2) 312 Supplying, erecting, testing and commissioning ofstand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC(13-11-3) 313 Supplying, erecting, testing and commissioning ofrust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete.(13-11-4) 314 Supplying, erecting, testing and commissioning ofrust free microphone table stand of chrome plating/powder coating or S.S. material,up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.(13-11-5) 315 Supplying, erecting, testing and commissioning of2 core shielded cable complete asper specification no.FF-PA/MCC(13-11-6) 316 Supplying, erecting, testing and commissioning of1.5 sq. mm speaker wire complete.(13-11-10) 317 Supplying, installation, testing and commissioning of 220/250Volts, single phase, 50 Hz Siren of 3.25 km range (Diametrical),horizontaldoublemountingtype of0.5 HP 6000 RPMon C. C.foundation complete as per specification no. SRN-AS/SM 318 Supplying and erecting ABC powder type fire exitinguisher as per IS: 13849/15683 of 6 kg capacity with necessary clamp for erection on wall (Non-CSR) 319 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fire signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 300 mm X 100 mmas per IS 12349-1988 320 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fir signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 450 mm X 100 mm as per IS 12349-1988 321 Providing and fixing of Emergency Exit Lights LED Beam-II with exit high glow LED White lamps working on battery 12 V 7.6 Ah for duration 4-5 hours (approx) wattage of LED lamp is 26 watt each 2 Nos. of lamp total wattage 52 Watts Weight of unit will be 5.4 kg input voltage 220 V AC 50 Hz Output Volatge 12 V DC the outer cabinet is powder coated, for safety purpose DC & AC fuse system is given in unit as per IS 9583-1981 322 Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 323 Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 324 Supplying and erecting 20mm dia. corrugated flexiblepolypropylene conduit 325 Supplying and erecting 10m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.. 326 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC 327 Supplying, fixing, and configuring 24 ports, POE switch in provided rack as perspecification No. WG-NWC/ENS(1-11-3) 328 Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. 329 Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA 330 Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK 331 Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 1 hrs. PWM & IGBT based,with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS 332 Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-12) 333 Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM. 334 Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM 335 Supplying, installing, testing & commissioning of 64/80 Ch Network VideoRecorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 MegapixelResolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided,Atleast one HDMI output of 4K resolution, atleast one VGA output with outputup to 1920 × 1080,Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power,Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANRTechnology,8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptiveEthernet interface,support multi brand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging andprogramming etc. complete as per specificationss no. CCTV-NVR 336 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Portof NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected inposition in provided NVR as per specification no. CCTV-HDD 337 Supplying & erecting 43 professional LED display with 1920*1080 (FullHD) Display, suitable for 16/32 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand andwiring connections etc. complete as per specifications no. CCTV-MON 338 Supplying and erecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON(1-2-3) 339 Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-5) 340 Supplying, installing, testing and commissioning of15 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 45 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnectingwires / cables up to solar ON GRIDinverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 yearsincluding net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG(4-5-4) 341 Supplying and erecting switch disconnector fuse (SDF) switch 415V up to 63A, open execution, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3HRC - DIN type fuse,insulation voltage 1000 Vfor enclosing in panel with rotary handle for ON / OFF operation (without HRC fuse)(5-1-17) 342 Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A(5-10-26) 343 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 344 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark,accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh andMD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power &with transparent hinge type box completeerectedonpolished teak woodboardduly wiredwithrequiredsizeof weather proofPVC wires duly testedby electric supply company.(6-3-3) 345 SupplyinganderectingAC three phase HT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz,with backlitLCD display, optical port& RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. 346 Supplying, installtion & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested forImax 40 kAfor three phase and neutralwith compliance to IEC 61643-11 as per specification no. CP-SPD(6-6-6) 347 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-33) 348 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 349 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-2) 350 Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.(9-2-1) 351 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 352 Supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete.(9-3-1) 353 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 354 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 355 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 356 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 357 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.(1-6-29) 358 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 359 Supplying, erectingandmarking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-7) 360 Supplying, erectingandmarking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-13) 361 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 362 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 363 Supplying, fixing, and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO(5-6-13) 364 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-9) 365 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-33) 366 Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI(9-1-5) 367 Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete.(9-2-4) 368 SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mmhigh· Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high· Lift shaft available having clear size of .1900 mm wide x 1900 mmdeep, 1500 mm Pit depth, 4250 mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.13) 369 SITC of Electric Traction Passenger cum Stretcher/Hospital Liftwith · Rated capacity :- 15 Passenger/1020Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL [applicable for PassengerLift with MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x2000mm high· Clear Car size of 1000 mm wide x 2400 mm deep x 2250mm high· Lift shaft available having clear size of 1800 mm wide x 3000 mmdeep,1500 mm Pit depth, 4250 mm Overhead· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.17) 370 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 371 For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 372 Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC(1-1-9) 373 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 374 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 375 Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TRcapacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 376 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. 377 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. 378 Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 379 Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 380 Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 381 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 382 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 383 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 384 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 385 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 386 Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers, filters at position complete. 387 Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 388 Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODUs can be controlled and up to 992 IDUs can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. 389 Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. 390 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 391 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. 392 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 393 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-94) 394 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-95) 395 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-96) 396 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 397 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 5000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 398 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 3000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 399 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 2500 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 400 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 401 Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. 402 Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PVC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system. 403 Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC 404 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 405 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 406 Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO 407 Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-2) 408 Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-3) 409 Supplying and erectingGI sheet 1.25 mm (18 SWG)having zinc coating of 350 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. 410 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 411 Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 412 Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
Contract Date: Sep 27, 2025 Contract Value : 16.94 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
45.
Educational and Research Institute #7859364 AOC
Supply Of Cctv, Photocopier Machine, Dlp Projector Office And Laboratory Equipments , Finance And Accounts Section , Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wi-Fi Network, Machine Type A3, Monochrome Laser Multification, Multiple Copies: Up To 9999, 2Gb Ram, 2 Cassette, 01 Byepass Tray, Duplex Print, Colour Touch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model With Stabilizer & Trolley.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , General Administrative Deptt , Photo Copier Machine:Warm-Up Time 18 Seconds 17.7 Seconds 18.6 Seconds 17.9 Seconds 19.1 Seconds 18.8 Seconds, First Output Speed: B/W 4.1 Seconds 3.9 Seconds 3.8 Seconds 3.6 Seconds 2.7 Seconds 2.3 Seconds, Continuous Output Speed 25 Ppm 30 Ppm 35 Ppm 40 Ppm 50 Ppm 60 Ppm, Memory: Standard 2 Gb Hdd: Maximum 320 Gb, Ardf Capacity 100 Sheets, Spdf Capacity 220 Sheets Weight With Ardf: 71 Kg With Spdf: 76.5 Kg,Dimensions (W X D X H) With Ardf: 587 X 673 X 913 Mm With Spdf: 587 X 673 X 963 Mm,Power Source 220 - 240 V, 50 - 60 Hz Copier Multiple Coping Up To 999 Copies, Resolution 600 Dpi,Zoom From 25% To 400% In 1% Steps , Cctv Camera And System , 32 Ch Nvr Supports Smart H.265+, H.265, Smart H.264+, H.264 And Mjpeg Decoding Formats. ? Max. Decoding Capability: 8 × 1080P@30 Fps Or 2 × 8 Mp@30 Fps. ? Max. 160/160/80 Mbps Incoming/Recording/Outgoing Bandwidth. ? Supports Ip Cameras With A Resolution Up To 12 Mp. ? Ai By Recorder Supports 4-Channel Smd Plus. ? Ai By Camera Supports Face Detection And Recognition, Perimeter Protection, Smd Plus, People Counting, Stereo Analysis And Heat Map. ? Supports Eptz, And One-Click Arming And Disarming Dh-Nvr 4232-4Ks2/L] , Hard Disk ; Supply & Installation Of Hdd-4Tb Capacity With Connection, Testing And Commissioning In Security Cabin. (As Directed By Engineer In Charge/ Elect. Consultant) Skyhawk 4 Tb Surveillance, Internal Hard Drive Hdd – 3.5 Inch Sata 6 Gb/S 64 Mb Cache For Dvr Nvr Security Camera System With Drive Health Management , Switch : 8+2 Port Poe Switch Gigaoutput,Supplying, Fixing, And Configuring, Web Smart Power Over Ethernet, Switch Of 8+2 Ports On Provided Rack, Suppling, Erecting & Testing Commissioning. , Camera: Dome Ip Camera 4-Mp 1/3 Cmos Image Sensor, Low Luminance, And High Definition Image. • Outputs Max. 4 Mp (2560 × 1440)@25/30 Fps. • H.265 Codec, High Compression Rate, Ultra-Low Bit Rate. • Built-In Warm Light, And The Max. Illumination Distance Is 15 M. • Roi, Smart H.264+/H.265+, Flexible Coding, Applicable To Various Bandwidth And Storage Environments. • Rotation Mode, Wdr, 3D Nr, Hlc, Blc, Digital Watermarking, Applicable To Various Monitoring Scenes. • Abnormality Detection: Motion Detection, Video Tampering, Audio Exception, Network Disconnection, Ip Conflict, Illegal Access, And Voltage Detection. • Built-In Mic. • 12 Vdc/Poe Power Supply [Dh-Ipc-T1b49p] , Surface Box: Surface Box Square 4X4 Inches (White) For Cctv Cameras , Monitor : 32 Led Monitor 80 Cm (32 Inches) G Series Hd Ready Smart Led Google Tv Ar32gt2841hdfl (Black) , Wireless Mouse : Wireless Mouse130 Wireless Compact Mouse, 1K Dpi Optical Sensor, 2.4Ghz Wireless Nano Usb, 10M Range, 3Button(Left,Right,Scroll) Up To 3M Left/Right Clicks, 10Month Battery, Ambidextrous, Ergonomic, Gy51l52638 , Cable:Cat-6 Cable Per Ft With Pipe Fitting .Heavy 0.51Mm Copper Gauge.Ec Grade Copper. International Standard Twisting .Outer Hdpe Jacket. Fluke Tested (In Rft) , Connectors:Connectors With Networking D-Link(India) Rj45 Connector Module Plugs. All Networking Clip, Rj45 Connector Colour White , Camera Installation Charges , Tv Stand: Tv Stand 18-55.. Sk Expertise Wooden Wall Mounted Tv Unit, Tv Cabinet/ … , Switch:8 Port Desktop Switch Gigabyte Up To 2000 Mbps. Ieee 802.3X Flow Control.Plug And Play Installation. , Central Administrative Service Unit (Rs. 220000.00) , Cctv Camera , 8 Ch Hd Dvr , 1000Gbhard Disk (Sv 35) Sata Hd , Dome Hd Camera , Installation Charges , Photocopier Machine:Faction: Print /Scan /Fax/E-Mail, No. Of Trays-2, Color-Black And White, Print Technology= Laser, Print Speed:30 Ppm, Supporting Paper Size:A3, Memory: 2 Gb, Warn Up Time: 4 Second Or Less, Resolution 1200X1200,Processor: 1.6Ghz Dual Corel Processor, , Innovation, Incubation & Linkages , Photocopier Machine: Speed B/W:25 Pages Per Minute, Resolution: 1200 X 1200 Dpi, Toner Impression B/W: 14,600 Impressions, Copier Type: Office Copier, Colour Capability: Black And White Copier, Properties : Copier-Printer-Scan-Fax Etc., Dimensions (Hxwxd):35-3/4” X 22-1/4” X 27-1/8”, Weight: 174 Lbs,Power: 120 Volts, 9.3 Amps , Collegiate Section , Multifunction Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wifi Network, Machine Type A3, Monochrome Laser Mulification, Multiple Copies: Up To 9999, 2Gb Ram, 2 Cassette, 01 Bypass Tray, Duplex Print, Colour Touch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model With Stabilizer & Trolley.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , Boy’S Hostel , Ip Camera Dome 2 Mp: Image Sensor-1/2.8 Progressive Scan Cmos, Min. Illumination-Color: 0.002 Lux @ (F1.4, Agc On), B/W: 0 Lux With Ir, Shutter Speed-1/3 S To 1/100,000 S, Wide Dynamic Range -120 Db, Day & Night-Ir Cut Filter, Angle Adjustment-Pan: 0° To 360°, Tilt: 0° To 90°, Rotate : 0 To 360, Lens Type-Fixed Focal Lens, 2.8, 4, And 6 Mm Optional, Itis Types-Fixed, Aperture-F1.4, Supplement Light Type-Ir, Ir Range-Up To 40 Mtrs, Ir Wavelength-850 Nm, Smart Supplement Light-Yes, Max Resolution-1920 X 1080, Video Bit Rate -32 Kbps To 8 Mbps, Environment Noise Filtering - Yes, Audio Sampling Rate-8 Khz/16Khz/32Khz/44.1 Khz/48Khz, Built-In Mic-Yes, Audio Compression-G.711Alaw/G.722.1/G.722.1/G.726/Mp2l2/Pcm/Mp3/Aac-Lc, Ethernet Interface - 1 Rj45 10 M/100 M Self-Adaptive Ethernet Port, On Board Storage - Built In Memory Card Slot, Support Micro Sd/Sdhc/Sdxc Card, Up To 512 Gb, Basic Event-Motion Detection (Human And Vehicle Targets Classification), Video Tampering Alarm, Exception, Face Capture - Yes, Perimeter Protection-Line Crossing Detection, Intrusion Detection, Region Entrance Detection, Region Exiting Detection, Protection Ip67 (Iec 60529-2023), Ik10 (Iec 62262:2002). , Ip Camera Bullet 2 Mp Image Sensor-1/2.8 Progressive Scan Cmos, Min. Illumination-Color: 0.002 Lux @ (F1.4, Agc On), B/W: 0 Lux With Ir, Shutter Speed-1/3 S To 1/100,000 S, Wide Dynamic Range -120 Db, Day & Night-Ir Cut Filter, Angle Adjustment-Pan: 0° To 360°, Tilt: 0° To 90°, Rotate: 0° To 360° ,Lens Type-Fixed Focal Lens, 2.8, 4, And 6 Mm Optional, Iris Type -Fixed,Aperture-F1.4,Supplement Light Type-Ir,Ir Range-Upto 40 Mtrs, Ir Wavelength-850 Nm, Smart Supplement Light-Yes, Max Resolution-1920 X 1080,Video Bit Rate- 32 Kbps To 8 Mbps, Environment Noise Filtering- Yes, Audio Sampling Rate- 8 Khz/16 Khz/32 Khz/44.1 Khz/48 Khz, Audio Compression- G.711Ulaw/G.711Alaw/G.722.1/G.726/Mp2l2/Pcm/Mp3/Aac-Lc, Ethernet Interface -1 Rj45 10 M/100 M Self-Adaptive Ethernet Port, On-Board Storage -Built-In Memory Card Slot, Support Microsd/Sdhc/Sdxc Card, Up To 512 Gb, Basic Event-Motion Detection (Human And Vehicle Targets Classification), Video Tampering Alarm, Exception, Face Capture- Yes, Perimeter Protection-Line Crossing Detection, Intrusion Detection, Region Entrance Detection, Region Exiting Detection, Protection -Ip67 (Iec 60529-2013) , 32 Channel Network Video Recorder 2 Mp: Up To 32-Ch Ip Camera Inputs H.265+/H.265/H.264+/H.264 Video Formats Up To 12 Mp Resolution, Hdmi 1 -4K (3840 × 2160)/60Hz, 4K (3840 × 2160)/30Hz, 2K (2560 × 1440)/60Hz, 1920 ×1080/60Hz, 1600 × 1200/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 ×768/60Hz, Hdmi1/Vga Simultaneous Output, Hdmi 2-1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz,Hdmi2/Vga Independent Output, Network Protocol-Tcp/Ip, Dhcp, Ipv4,Hikconnect , Dns, Ddns, Ntp, Rtsp, Sadp, Smtp, Snmp, Nfs, Iscsi, Isup, Upnp™, Http, Https,4 Hdds For Continuous Video Recording, Up To 10Tb Capacity For Each Disk,4 Sata Interfaces Supporting Hot-Plug, Up To 256 Mbps Incoming Bandwidth, Network Interface -2, Rj-45 10/100/1000 Mbps Self-Adaptive Ethernet Interfaces, Audio Compression -G.711Ulaw/G.711Alaw/G.722/G.726/Acc/Mp2l2,Audio Output-1-Ch, Rca (2.0 Vp-P, 1 K?, Using The Audio Input ),Audio Input -1-Ch, Rca (2.0 Vp-P, 1 K?),Facial Detection And Analytics-Face Picture Comparison, Human Face Capture, Face Picture Search, Face Picture Library-Up To 16 Face Picture Libraries, With Up To 10,000 Face Pictures In Total (Each Picture= 512 Kb, Total Capacity = 150 Mb),Face Picture Comparison-4-Ch Face Picture Comparison Alarm, Performance Of Facial Detection And Analytics-1-Ch Human Face Capture (Hd Network Camera, Up To 4 Mp, H.264/H.265), False Alarm Protection (Perimeter Protection) - Up To 4-Ch 2 Mp (H.264/H.265) Video Analysis For Human And Vehicle Recognition To Reduce False Alarm; Up To 12 Rules In Total, , Surveillance Harddisk 6 Tb , Network Switch Poe 16 Port, 16X10/100/1000 Base-T Poe Port With 2 Sfp Uplink. 1610/100/1000 Mbps Gigabit Ethernet Ports 2 Sfp Port, 150 Watts Available Poe, Flow Control For Protection Against Data Loss, Maximum Distance Of 250M, Light Protection (6Kv), Operating Temperature : 0 To 400 C (32 To 104 Deg F) , Dome Camera Wall Mount Pvc Stand , Pvc Junction Box , 32 Let Tv (An Reputed Brand) , Cat6 Cable (Approx. 1525 Mtrs) (In Rmt) , Cable Laying Charges (Cat6 Cable) (Approx. 1525 Mtrs) (In Rmt) , Conduit Pipe / Casing Patti With Saddled Fitting ( Approx. 400 Mtrs.) , Single Mode Six Core Optic Fiber Cable (Armored) (Approx. 800 Mtrs.) , Optic Fiber Cable Paying Charges (Overhead) (Approx. 800 Mtrs.) , 1000 Base - Mini Gigabit Interface Converter , Fiber Patch Cord With Splicing Charges , Hdmk Cable 15 Mtrs. 4K , Network Rack 6U With Fan, Pdu & Standard Accessories. , Network Rack 15U With Fan, Pdu & Standard Accessories. , Setup, Installation, Crimping, Punching & Supervision Charges With One Year Warranty & Support. , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (500 Faces, 2000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable Up To 100 Students) Type - 100 % Copper Model , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (3000 Faces, 4000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable 100 To 3000 Students) High End. , Ro 120 Liter, 300 Gpd Pump 3 No., 300 Gpd Membrane 4 No., 20 Inch. Housing 3 No., 20 Inch Pre-Filter 1 No., 20 Inch. Carbon Filter 1 No., 20 Inch Sediment Filer 1 No., Fr- 600 3 Nos., 3/8 Pipe 25 Rft., Filter Set 10 Inch 4 Nos. , Deptt. Of Lifelong Learning &Extn. , Photocopier Machine:Multifunction Machine, Print Technology: Lazar, Mono Printing, And Cartridge Tech: Separate Drum And Toner (Dual Component), A3, Ram: 2048 Mb, Scanning Feature, Networking Feature, Ethernet 10/100/1000, Wi-Fi Direct. , Girl’S , Providing And Fixing Pa Ip Based Paging System With Automatic (Digital Timely Audio Playback System , Providing And Fixing Ip Based Network Paging Mic Console (Digital) , Providing And Fixing Ip Based Pa Network Intercom Unit , Providing And Fixing Software For Internet Protocol System (Ip Based)Software Features: User Management, Terminal , Providing And Fixing 415W Rack Mounting Installation Pa Amplifier , Providing And Fixing 25 W Ip 65 Sound Projector(With Lmt) , Providing And Fixing Pa Paging Microphone (With Chime) , Providing And Fixing15w Pa Column Speaker (With Lmt) , Providing And Fixing 6Wpa Wall Speaker (With Lmt) , Providing And Fixing Pa Active Monitor Speaker , Providing And Fixing 12U Lockable Metal Rack For System , Csr No. 13-9-10: Supplying, Erecting, Testing And Commissioning Of 1.5 Sq. Mm. Speaker Wire Complete (In Mtr) , Csr No. 1-2-9: Supplying, Erecting Pvc Tuning (Pvc Casing-N-Capping) Of Size 20 Mm With Accessories On Wall/Ceiling As Per Specification No. : Wg-Ma/Con (In Mtr) , Csr No. 1-14.46: Supplying & Installing Utp Networking Cat 7 Cable, 4 Pair 23, Awg Cate 6A Lszh Lan Cable, Standards Like Ansi/Tia 568, C.2, En50173, Iec 11801 2Nd Ed, 600 Mhz Speed Frequency Tested Up To 700Mhz With Third Party Certificate Etc. Complete. (Inmtr.) , Csr No. 1-14-1: Supplying, Installing & Testing Uto Connector (Rj-45) As Per Specification No. Wg-Nas/Utpc , Biometric Attendance System With Backup Power Supply : Face/Finger/Rfid Attendance Reader (500 Faces, 2000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable Up To 100 Students) Type - 100 % Copper Model , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (3000 Faces, 4000 Fingers, 1, 00,000 Logs Tcp Ip Usb) Suitable 100 To 3000 Students) High End. , Projector Screen : Royalty Licking Projector W-121.92 Cm X H-182.88 Cm , Lcd Tv : 49 Full Hd Resolution, Wall Mountable, Smart Phone Connectivity, Usb Port Latest Model. , Deptt. Of Biotechnology , Pcr System (3X32- Well)Block Format Interchangeable Thermal Accuracy: +- 0.25°C (35°C-99.9°C), High Throughput Compatibility Thermal Uniformity: ?0.5°C (20 Sec After Reaching 95°C) Reaction Speed Fast, Standard Dimension: 22X13x10.6 In. ( 56.5X33x27cm) Capacity : 32X0.2Ml Pcr Tube/Block Or 4X8wells Strips Of 0.2Ml Pcr Tubes/Block Voltage : 100/240V Display Type : 8.4 In Color Tft Lcd Touchscreen Product Type : Thermal Cycler, Warranty :Limited Warranty Thermal Range 0°C-100°C For Used With (Application) Pcr Programs Auto Restart (After Power Outages), Program Overwrite Protection User Interface Usb Wifi Cloud, Ethernet Max.Ramp Rate 6°C /Sec. (Block), 4.4°C, Sec (Sample Memory Usb And On-Board Weight: 41Lb.(18.8Kg) Block Configurations : 3X30well 2 Zone Veriflex Block , Autoclave Portable: All The Parts Are Made Ss-304 Grade, Easily Replicable Heater And Rubber Gasket Pressure Gauge And Spring Loaded Safety Valves And Steam Release/ Exhaust Vavae Fitted On Lid, Operates On 230 Volts Ac Single Phase 50Hz, Size: 12”X12”. , Analytical Balance:Capacity: 220Gm, Readability: 0.01Gm, Reparability: 0.001Mg Response Time: 2-3 Sec, Pan Size:128X128mm, Display: Lcd Backlight Calibration: External Calibration. , Mini Vertical Page Electrophoresis System:Mini Vertical Systems Are Predominantly Used For Protein Electrophoresis. Electrophoresis System Can Accommodate Up To 4 Hand Cast Gels And To Commercial Precast Gel To Provide Complete Flexibility For Individual Research Needs While Unique Sliding Clamp Technology Within The Page Insert Facilitates Samples, 1Mm Thick Combes Including Caster. , Automated Densitometer With 4 Reading Channels: Densitometer A Universal Densitometer Scanner With Software Capable Of Reading 144Testper Min. Is Available For Band Quantitation Following Post Electrophoresis Staining Ordering Information-Cellas Gel Application Packages Equipped With Bridges Applicator And Clinical Test Kit, 1X4 – Specimen Semi Micro Applicator Volume Applied/Sample Band With Compatible Strip Size: 5.7X14cm, Cellasgel Wet Membrane Bridges And Densitometer, 1X8.5 Cm Bridge For 1X5.7X7x14cm Or 2X2.5X14cm Cellasgel.Strip Cat No. Cslbg8.55 Terbo Scan Software Densitometer (Excludes Computer And Scanner) Cat No. Csldens Flat Belt Scanner For Turbo Scan Software Cat No. Csscan , Uv Transilluminator: 312 Nm Singlewavelength Transilluminator For Detection Of More Than 0.1Mr Of Dna Filter Area (Cm) Uv 20X20cm. , ?Controller Baed Ph System:Touch Screen Display 4.3 Ubcg Tft, User Password Protection Available Microprocessor Controlled And Completely Programmable, Large Lcd Display With Time Setting, Temperature Indicator And Controller, Autotuning For Convenience And Optimal Processing Efficiency, Variable Power Output Control, , Auto Frequencytrucking Output Aptitude 0-100% Adjustment Automatic Fault Alarm Frequency 2-25Khz-Automatic Typing Process Capacity 0.5-500Ml (Approx..) Probedie (Titanium Alloy Std. 6Mm (1/5 Inch) , Deptt. Of Botany , Gel Viewing Model Endure: High Sebsututy Fir Dna/Rna Detection, Compatible With Sy Br Green Family Stains, Provision Of Window With Uv Protecting Shield For Safety From Uv Damage, Quartz Ultra Violet Light For Longer Shelf Life, Side Doors For Precise Cutting Of Gels, Use Of White Light, 302Nm, 254Nm, And 365Nm Uv Wavelength Having Emission Of Average Light Power On The Plate To Obtain Shadow Free Images, Transilluminator Is Housed In A Closed Chamber For Case Of Gel Observation And Graphic Display Capturing Under Daylight, White Light Board Available At Additional Price. , Rotary Evaporator:Automation Grade: Automatic, Capacity: Standard, Water / Oilheating Bath With Wide Temperature Range:Temp.: Ambient To 200 Deg. C (Accuracy ± 0. 5 Deg. C)Rpm : 10 To 150 (Accuracy ± 1 Rpm), Sensors : Pt – 100, Display : Lcd 16X2, Heater : 1000 Watts Stainless Steel, Power# : 220 / 230V Ac, 50 Hz 01 , Incubator And Oven Dual Model Twin: Horizontal Air Circularly By Double Air Duct,High Efficiency And High Uniformity Pid Controller Etc , Precision Balance: Display Green Led Display, Minimum Capacity 20 G, Maximum Capacity 1000G , Readability 20 G, Repeatability 0.02 G, Stabilization Time 1 Seconds, External Calibration Weight 500 G, Net Weight 5 Kg , Programmable Micro Centrifuge:Lcd Display, Rotor Capacity: 12 Places X 1.5/2 Ml Tubes, Centrifugation Speed: 500-15000 Rpm, Timer : 15 Seconds To 99 Minutes, Power Supply: 110V-240V; 50 Hz, Power Consumption 100 W, Dimensions: 230 X 220 X 130 Mm, Approximate Weight: 6 Kg. , Multimedia Projector:Display Type: Lcd, Brightness:2000-4000 Lumens, Resolution:Wxga Resolution,Lamp Life: Long Lamp Life Up To 12,000 Hours*2 In Eco Mode, Long Lamp Life:Up To 12,000 Hours*2 In Eco Mode, Connectivity: Hdmi Connectivity, Projection Technology: Rgb Liquid Crystal Shutter Projection System (3Lcd), Direct Power On / Off: Yes , Ph Meter : Range- 0.00-14.00, Calibration- Auto Calibration With Slope Display , Distillation Unit: Led Indicator, Energy Efficient And Eco-Friendly, Water Tank Capacity 4L, Water Distillation Capacity 1.5 L/Hr , Stereo Trinaculor Microscope: Smoot Focus Control And A Fluid 0.8X-8X Greenough Zoom System Guarantee Stress Free Operation With Minimal Ware And Tare To Gears. Excellent Image Quality And Optional Performance With Infinity Parallel Optical System.Comfortable Operation With Ergonomic Design Principal With Led Light For Both Incident And Transmitted Illumination.Providing Even Illumination And Life Expectancy Can Reach 6000 Hrs.A Wide Rang Of Accessories To Be Equipped With The Microscope For Multi-Purpose.It Is An Outstanding Assistant In Industrial, Medical And Scientific Research Areas. Optical Syst4em: Greenough, Zoom Ration: 1:10, Eyepieces: Wide Field 10X/22Mm/23Mm (Optional, Objective: Plan Objective 1X,Viewing Body: Binocular / Trinacular With Beam Splitter, Working Distance: 78Mm, Magnification Range: 8X To 80X (Click Stop) With 10X Eyepieces, Object Field Diameter: 6.6Mm To 28.5 Mm, Eye Guards: Rubber, Retractable, Illumination Control: Incident/ Transmitted / Combined Illuminations Control Buttons With Rheostat Dial For Light Intensity Control, Led: Led 3.3W With Intensity Control With 60,000 Working Hours, Free Of Uv And Ir Emissions, Power Supply: Universal 220-240V/60Hz Integrated Power Supply With Voltage Flux Stabilizer, Optional Accessories: Pointers, Micrometre Reticules, Eyepieces (15X20x, 25X), Auxiliary Lens 0.3X, 0.5X0.5X, 2X). Digital Cameras Usb 3.0, Hdmi Camera, 4K Camera, Retina Display System, Dark Field Withy Tweezer, Battery Back, Fluorescent Attachment Kit. , Side-By-Side Refrigerator : 564 L Frost Free Multi Air Flow System Side-By-Side Refrigerator (Rs Eonvelvet 579 Rfd Pl St, Platinum Steel, With Advanced Controls) , Binocular Microscope:4X, 10X, 40X And 100X Monocular Head, Trinocular Head, Usb Digital Camera , Double Beam Portable Uv Visible Scanning Spectrophotometer, 190-1100 Nm:Wavelength Range:190-1100 Nm, Optical System: Double Beam, Mobility: Portable, Spectral Bandwidth: 1 Nm,Wavelength Accuracy+-0.3 Nm, Wavelength Repeatability+- 0.2 Nm, Photometric Accuracy+- 0.3% T, Lamp Type Deuterium Lamp, Usage / Application, Lab And Industrial Use, Material Plastic, Steel, Standard Iso Certified, Display Digital , Plant Growth Chamber :Temperature Range Lights Off: 5°C To 60°Clight On: 10°C To 60°C. Incorporated With Microprocessor Based Programmable Pid Temperature / Humidity Control System For Accurate Control Of Humidity. Temperature And % Of Rh Are Displayed On Digital Meter, Programmable Timer For Regulating Day / Night Effect, Temperature Range: 10°C To 50°C, ± 0.5°C, Humidity Range : 40% To 95% + 2% Rh, Light Level : 2,000 To 16,000 Lux, Capacity : 200 / 400 / 800 / 1000 Litres , Business Administrative And Management , Podium Lectern:Public Address Podium With Wireless Mike, Lecture System, (Receiver Amplifier Power Output 60 Watts, Max. Speaker Impedance (External) 4 W Input Channels Sensitivity Mic 1:12, 0Mv Mic. 2-7 Mv, Aux Positional 1:350Mv, Aux Position 2:180Mv, Aux Position 3, 300Mv, Aux Position 4-700Mv, Frequency. Response Tom=Ne Control Bass +/- 10Db At 80 Hz, Treble +/-6Db At 8, Khz, Rec Output-Iv, Power Supply Ac 220-240V, 50/60 Hz, Power Consumption Ac 100W, Dimensions W 420Xh1100xd5800mm, Weight 108.30Kg, Handheld Wireless Transmitter Microscope Dynamic Unidirectional Stability Various Emissions 45Db, Rf Output Power, 15Mw, Frequency Response 80-16.000Hz, Dynamic Range 100Db Or (Latest Version) , Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) , Collar Mic With 50-Meter Range , Trolley Speakers:Partyboxx310 Portable Bluetooth, Party Speaker 240W, Monstrous Pro Sound Dynamic Light Show Backlit Panel, Telescopic Handle And Wheels, Guitar & Mic Support Party Box App (Black , Deptt. Of Chemical Technology , Temperature Control Trainer: The Process Setup Consists Of Heating Tank Fitted With Thermistor-Controlled Heater For On Line Heating Of The Water. Water Is Supplied From Laboratory Constant Head Tank And Its Flow Can Be Manipulated And Measured By Provided Rotameter. The Temperature Of The Heated Water Is Sensed By Rtd Sensor. This Measured Variable Through Temperature Transmitter Is Communicated To Digital Indicating Controller. Error Is Calculated And Output, Accordingly, Is Communicated To Thermistor Controlled Heater To Achieve The Set Point. These Units Along With Necessary Piping Are Supported In A Well-Designed Housing And Are Fixed On Base Plate.Water Supply 2 Lpm. Electricity Supply: 1 Phase, 220 Vac. Temperature Transmitter : Input Rtd Pt-100 (0-100°C), Output 4-20 Ma. Process Tank : Material Stainless Steel, Capacity 0.5 Lit, , Emisivity Measuremet Apparatus:Specifications: Test Plate And Black Plates - 160 Mm. Dia, Aluminium Plates, Mounted In Panel With Mica Heater Inside. Instrumental Panel Consisting Of Digital Voltmeter And Ammeter For Input Measurement To Both Heaters Through A Selector Switch. Separate Dimmer Stat For Both The Plates.Multichannel Digital Temperature Indicator.A Technical Manual Accompanies The Unit.The Unit Provided With An Attractive & Rust Proof Powder Coating. Services Required 1) Space Area Of 1.5M X 1M. At Working Height. 2) 230V, 15A, Ac Supply With Earthling Connection. , Spiral Type Heat Exchanger: The Unit Consists Of A Spiral Type Heat Exchanger, In Which Cold Fluid Is Cold Water And Hot Fluid Is Hot Water, Which Is Obtained From A Water Heater. The Inlet And Outlet Connections Of The Fluids Are Positioned So As To Make The Exchanger Counter Flow Type. Hot And Cold Fluids Pass Between Alternate Plates. Various Measurements Provided Enable The Students To Determine Heat Transfer Rate, Lmtd, Heat Transfer Coefficients And Effectiveness Of The Heat Exchanger. Specifications 1) Heat Exchanger – Spiral Type Heat Exchanger 2) Hot Water Heater -3 Kw Capacity. 3) Measurement Flask 4) Thermocouples To Measure Inlet And Outlet Temperatures Of Water. 5) Flow Control Valves. 6) Digital Temperature Indicator. 7) Hot & Cold Water Pumps To Circulate Water. A Technical Manual Accompanies The Unit. , Thermal Conductivity Of Metal Rod : Technical Specification: Metal Bar: Material-Copper; Length 400 Mm (Approx.); Diameter: 25 Mm, Insulating Shell: Length 250 Mm; Diameter 200 Mm, Cooling Water Jacket: Length 75 Mm; Diameter 100 Mm, Heater: Nichrome Wire., Water Flow Measurement: By Measuring Flask, Control Panel Comprising Of Digital Voltmeter: 0-250 Volt., Dimmer Stat : 0-230 V; 0 - 2 Amp, Temperature Sensors: Rtd Pt-100 Type., Digital Temp. Indicator: 0-199.90C, With Multi-Channel Switch, With Standard Make On/Off Switch, Mains Indicator Etc., The Whole Setup Is Mounted On A Powder Coated Base Plate., Control Panel: Standard Make On/Off Switch, Mains Indicator Etc., Instruction Manual : An English Instruction Manual Will Be Provided, Along With The Apparatus , Stefan Boltzmann Apparatus : Hemisphere : Dia 200 Mm Approx. Made Of Copper, Jacket: Die 200Mm Approx. Made Of Steel, Watertank Stainless Steel 12 Litre Capacity, Heater: Nichrome Wire Immersion, Digital Temp Indicator: 0 To 250 Degree Celsius, Temperature Sensor:, Thermocouples Cr-Al Type-5 Nos , First Order System : Thermometer Range -10°C– 0 – 100°C Thermometer, Tube Id 22Mm Heating Bath, 315Mml, Ss304. Heater Type Electrical Coil, Capacity 3 Kw. Timer Type Cyclic Beeper Time Setting Range 2-10Sec. , Forced Convection Apparatus : Control Panel -Stand Alone Metallic Powder Coated Panel, Specimen: 32Mm, Dia, 3 Mm Thick, 400Mm Long – Copper, Blower: 650W, Volume Of 3M3/Min, Reputed Make , Heater: 32 Mm Dia, 75Mm Width Band Heater -250Watts , Manometer: 6” U Tube Manometer With Water, Voltmeter: Digital Voltmeter Of ,Range 0-300V Ac , Ammeter: Digital Ammeter Of Range 0-20A Ac, Temperature Indicator: Digital Temperature Indicator ,0-400°C .Thermocouples: Teflon Coated Cr –Al (K-Type)-8 No., Dimmer Stat 230V,2A. , Friction Factor (Pipe Lines) Apparatus : Block Type Acrylic Differential Manometer (250-0-250 Mm), Flow Control Valve To Change Discharge, Two Pipes – (Length Of Pipe Between Two Pressure Tapings 1 Mtr) A) Dia Of Pipe - 0.022 M (For Pipe 3/4”), B)Dia Of Pipe 0.016 M (For Pipe ½ “Transparent Pizometer Tube With Scale To Measure Measuring Tank Discharge Measuring Tank 295 X 345 X 345 Mm Usha Or Crompton Greaves Motor For Recalculating Type Unit - 0.5, H.P. Self Priming ,Stop Clock, All The Tanks Are Provided With An Attractive Antirust Powder Coating. , Centrifugal Pump0.5 Hp , Centrifugal Pump 1Hp , Vacuum Pump: Specification Model: Dc ? Voltage / Freq.: 100~240V, 50/60 Hz, Max. Power: 120W, Max. Vacuum: 7 Mba, Max. Flow Rate: 37 L/Min,Resolution: 1 Digit,Pressure Display: Mbar, Hpa, Torr, Display:7” Touch Screen, Measuring Range: 1100 ~ 0 Mbar Abs., Measurement Accuracy: ± 2 Mbar (After Adjustment, Constant Temp.), Setting Range: 1013 ~ 0 Mbar, Motor Speed: 1-100 %, Adjustable, Housing Material: Ss304, Plastic, Venting Valve: Yes, Auto-Cleaning: Yes,Noise Level: 50 Dba, Hose Barb: Id 10,Moisture Trap: Yes,Safety: Fuse, Error Message,Dimension ( L X W X H ): 44 X 38 X 25 Cm, Net Weight: 15 Kg , Lcd Projector - Ultra X 35U, Display Type – Dlp, Brightness - 3000 Lumens, Resolution - 1024X768 Pixel, Throw Ratio - 1.5 ~ 1.65 M, Projection Size - 0.76-7.62 Mtr, Contrast Ratio - 22000:1, Computer Compatibility - Vga (640 X 480) To Wuxga (1920 X1200), Power Supply (Voltage, Hz) - Ac100 To 240 V, 50 To 60 Hz, Aspect Ratio - 16:9, Weight - 2.8 Kg, Projection Lamp- 210 W Zoom - 1.3: 1, Dimensions - 311.81 X 104.7 X 244.12 Mm With Ceiling Installation Bracket, Cable, Socket And All Accessories Pins. With All Installation Charges. And Screen Fitting On Wall , Variable Speed Peristaltic Pump : Flow Range: 0.0015-1140Ml/Min, Adjustable, Speed Range: 0.1-300Rpm, Resolution: 0.1 Rpm, Flow Rate Variable From : 0.0015-1140Ml/Min, Flow Error <0.5%, Display: 4 Led Display Current Speed Or Flow Rate, Speed Control: Digital Knob Control, Power< 35W, External Control Interface: Start/Stop, Direction, Speed Control (Optional), Rs485serial Communication, Operating Conditions: 0-400C Temperature, Relative Humidity<80%, Drive Dimensions: 234×144×140Mm, Drive Weight: 4.3Kg Ip: Ip 31 , Portable Digital Thermometer : Precision Portable Digital Thermometer With 7-9 Inch Long Probe Temperaturerange: 750Oc Or More , Portable Digital Thermometer : Portable Digital Thermometer With 20 Inch Long Probe, 4 Mm Diameter, Temperaturerange: 750Oc Or More , Cloud & Pour Point Apparatus: Double Wall M. S. (As Per Ip 58 Astm – D-36, Astm – E – 28 & Is 205/78), For Two Tests: The Apparatus Consists Of Stand Units With Drain Plug And Cover With Provision For Fitting Thermometer And A Filling Aperture For Adding Freezing Mixture. Glass Jars For Containing Oils, Jackets, Discs And Gaskets As Specified , Labblender: Blender Type:-Seven Speed Blender, Rpm:-3500 To 22000, Container:-Stainless Steel Jar-Glass Jar (Auto Cleavable) Controls:-Push Buttons Capacity:-1 Liter Power Supply:-220 Volts Safety Feature:-Circuit Breaker Certification:-Ce Marked , High Pressure Reactor For Hydrothermal Synthesis With Heater & Control System : Setup Consists Of The Following Teflon Lined High Pressure Vessel With Heating & Control System With Agitation Facility (Magnetic Stirrer A) Ss Pressure Vessel:- M.O.C. Ss-316 Wall Thickness:9-10Mm (Approx..0 Made From Ss-316 Solid Bar Stock , Vessel Head:-M.O.C. Ss-316 It Will Consists Of A)Pressure Gauge : 2” Dia (Ss-316) End Connections: ¼” Bsp Male Range; 0-20 Kg/Cm2 Threaded Connections Will Be Provided For Pressure Gauge & Temp.Sensor B) Heating System: Heating Source : Ceramic/Mica Band Heater Of Suitable Dimensions Will Be Provided Power Supply : 230V Pt:-100 Sensor: Provided Temp. Control ; By Pid Temp. Controller Cum Indicator Display: Digital C) Teflon Vessel: M.O.C. : Teflon (Ptfe) Wall Thickness ; 3-4 Mm (Approx.) Volume; 50-200 Ml (Approx...0 Safe Operating Temp: 160Oc (Approx...) D) Stirring / Agitation ; Suitable Magnetic Stirrer For Stirring Application With Digital Display Of Rpm/Speed Teflon Coated Bar For Stirring : Provided Application : For Hydrothermal Synthesis/Material Synthesis Supplied With Viton “O” Rings Part No. Hbs-Vr-01-02 Nos Ellen Key- 02 Nos Ellen Bolts – 06 Nos , Deptt. Chemistry , Sound System For Auditorium Hall : Sound System Aba5000 =02 Nos. Active Speakers-Aba4000- 02Nos, Mixer-Premix – 1442=01 Nos, Uhf Wireless Mic (Dual) Awm 700 Ul- 01 No., Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) Including All Setup In Hall (In Set) With Installation , Aspirator Waterjet Vacuum Pump: Jet Vci Ji, Suitable Water Circulator Pump, 0.5 Hp Ss Water Tank , Ss Cabinet Cover Jet With Two Non Return Valve, 70 Mm Hg , Magnetic Stirrer: With Hot Plate, Regulator , Digital Electronics Balance: Capacity 0.0001 To 200 Gm , Fume Hood For Laboratory:Rectangular Std. Size, Fibre Fabricated, 4 Ftht, 850 Mm Work Space , Eye Wash Station:Designed To Deliver Fluid To Both Eyes Simultaneously Flow Rate Of Not Less Than 1.5 Litres/Minute , Microwave Synthesis System: Cap 3 Lit, Power 700 Wt, Automatic Soft Touch Control Panel , Hot Plate: Circular, With Temp Control, , Capillary Column For Gas Chromatograph For Natal Ultimo 2100 Model:2 Mm Mesh Size 80-100 , Deptt. Of Home Science , Mixer Grinder : 1000 Watt Heavy Duty Motor, Capacity 1 Liters No. Of Speeds -3 Stainless Steel Jars With Efficient Blades, (1 Ss Wet Jar With Blade, 1 Ss Dry Jar With Blade, 1 Ss Chutney Jar With Blade And Juicer). , Air Fryerdigital: 6.5 Lit / 1500 Watt ,Advance Digital Display Fry ,Bake Roast Wi-Fi Enabled , Induction Base Cookware: Sandwich Bottom, Stainless Steel Cookware With Lid And Fry Pan Compatible With Induction Cooktop And Gas Stove Capacity 1. 5 L, / 2.5 L And 3 L ( 3 Cookware’Sof Different Capacities And Fry Pan ) (In Set) , Weighingbalancedigital :6000 Gm X100mg , Superiorperformancepowercharge , Cd 300 Remote Display , Wireless Microphone System: Dimension-16.2X11x5.2Cm:300 Grams, Batteries -1 Lithium Polymer Batteries Required (Included) Hardware Platform-Smartphone. Tablet Compatible Devices -Camcorder, Tablet, Headphone, Smartphone. Special Features –Wireless , Mounting Hardware – Transmitter, Receiver,2 Wind Muff, One With Twocable, Dslr Cable, 2 Monitor Earphone.One Lighting Cable. ,Noise Level -75 Db ,Microphone Format –Microphone System ,Power Source –Battery Powered ,Battery Cell Composition –Lithium Polymer, Signal –To – Noise Ratio (Db)-75Db, Connector Type –Auxiliary , Material –Brass, Plastic. , Spotlight Wirelesspresentation Remote : Product Dimension -24X69x2.5 Cm: 49 Grams , Batteries – 1Lithium Polymer Batteries Required Hardware Platform –Pc, Compatible Devices –Projector, Laptop, Computer, Special Features-Bluetooth , Mounting Hardware – Presentation Remote, Proprietary Receiver User Documentationcharging Cable Pouch , Power Source –Battery Powered, Battery Description –Lithium- Ion Polymer, Battery Cell Composition –Lithium Polymer Connector Type –Bluetooth , Deptt. Of Geology , Tds Meter : Water Testing Kit, 0-9990 Ppm With Automatic Compensation , Ph Meter:Ph Tester Temperature & Water Quality Test , Digital Ec Meter: Water Testing Kit, 0-9990 Ppm With Automatic Compensation , Digital Thermometer: Steel Probe Professional Waterproof -Multicolour , Deptt. Of Library And Information Science , Trolley Speakers:Partyboxx310 Portable Bluetooth, Party Speaker 240W, Monstrous Pro Sound Dynamic Light Show Backlit Panel, Telescopic Handle And Wheels, Guitar & Mic Support Party Box App (Black) , Lcd Projector - Ultra X 35U, Display Type – Dlp, Brightness - 3000 Lumens, Resolution - 1024X768 Pixel, Throw Ratio - 1.5 ~ 1.65 M, Projection Size - 0.76-7.62 Mtr, Contrast Ratio - 22000:1, Computer Compatibility - Vga (640 X 480) To Wuxga (1920 X1200), Power Supply (Voltage, Hz) - Ac100 To 240 V, 50 To 60 Hz, Aspect Ratio - 16:9, Weight - 2.8 Kg, Projection Lamp- 210 W Zoom - 1.3: 1, Dimensions - 311.81 X 104.7 X 244.12 Mm With Ceiling Installation Bracket, Cable, Socket And All Accessories Pins. With All Installation Charges. And Screen Fitting On Wall , Deptt. Of Physical Education , Nine-Liter Wet Spiro Meter : This Academic-Quality Wet Spirometer Combines Reliability And Accuracy With An Increased Volume To Accommodate Students With Larger Lung Capacities., Large, Easy-To-Read Scale Graduations, Includes Disposable Mouthpieces And A One-Way Plastic Valve For Sanitary Classroom Use, Made Of Lightweight, Yet Durable, High-Density Polyethylene (Hdpe) Plastic And Aluminium. Determine Five Different Respiratory Volumes: Tidal Volume (Tv), Inspiratory Capacity (Ic), Inspiratory Reserve Volume (Irv), Expiratory Reserve Volume (Erv), Vital Capacity (Vc) , Emg Biofeedback Instruments: Emg Biofeedback Equipment Is Used For Controlling Ongoing Contraction And Relaxation Patterns. The Equipment Has Been Developed As Per The International Quality And Norms., It Highlights Awareness Of The Mechanism Of Muscle Flexure And Develops Voluntary Control Over Dysfunctional, Semi Voluntary Or Involuntary Muscle Activity., Uses: To Redress Disorder Related To Psychological, Psychosomatic, Stress , Vertical Jump System : Vertical Jump Training Measurement System, Specifications:Activity: Coaching, Training, Colour: Silver, Black, Red, Colourfamily: Multi Colour, Material: Metal, Product Height: 12 Ft., Product Type: Jump Training Accessory, Product Use/Compatibility: Measures Jump Height. , Multifunction Pedometer : Waterproof Full Colour Amoled Touchscreen, 0.95 Inch (2.41 Cms) Amoled Touch Large Colour Screen: Adjustable Screen Brightness, Dynamic And Vivid Display; Home Button Control, Belt Clip Design Makes Band Firmly Attached To Your Wrist., Spo2 Monitor-Spo2 Monitor Tracks Oxygen Saturation Levels In The Bloodstream So You Can Assess How Your Body Is Adapting During Workouts, Heart Rate Monitoring: Trueseen Allows 24-Hour Accurate Real-Time Heart Rate Monitoring And Warnings, On Standby Time Up To 14 Days And Saves Time On Frequent Charging, Multiple Sports Modes: Supports Outdoor And Indoor Run, Walking, Indoor And Outdoor Cycling, Pool Swim And Training Various Exercises Types, 5Atm 50 Meters Water-Resistant. Swimming Posture Recognition:, 6-Axis Sensor Recognizes Main Strokes, Records Speed, Distance, Number Of Turns, Calories, Average Swolf, And Other Data, Daily Activities Tracking And Monitoring: Step Count, Calories Burned, Distance Covered, Moderate To High-Intensity Activities Duration And Standing Status, Target Setting And Achievement Reminder , Force Plate Logger Sensor With Required Accessories : Dimensions: 11.2 X 10.7 X 2.4 Inches; 3.5 Kg, Height 2-1/2 Inches, Force Plate Logger Sensor For Measuring Constant And Changing Forces, Can Be Used To Study Newtons Laws Of Motion, Kinetic And Potential Energy, And Gravitational Force Strength For Further Research, Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure, Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16 -Bit Analog-To-Digital Converter (Adc) Resolution For Reading Range Of Values, Accessories : A Usb Module (Usb 200) To Connect Via Usb Cable To Pc Or Mac, Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wi-Fi Enabled Device (Smart Phone, Tablet, Computer) , Force Punching Plate With Required Accessories:Providing And Fixing, Dimensions: 12 X 11 X 2 Inches; 3.5 Kg, Force Plate Logger Sensor For Measuring Constant And Changing Forces, Can Be Used To Study Newtons Laws Of Motion, Kinetic And Potential Energy, And Gravitational Force Strength For Further Research, Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure, Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16 -Bit Analogue-To-Digital Converter (Adc) Resolution For Reading Range Of Values, Accessories : A Usb Module (Usb 200) To Connect Via Usb Cable To Pc Or Mac, Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wi-Fi Enabled Device (Smart Phone, Tablet, Computer) , Digital Back And Leg Dynamometer: For Measuring The Strength Of The Back And Leg., Dimensions: Approx.315(W) × 315(D) × 328(H) Mm, Weight: Approx. 3.7 Kg (Including The Weight Of The Handle), Automatic Stop: Approx. 1 Min After The Final Measurement, Power Source: Dry Battery Sum-4 × 2, Display: Lcd In 6 Digits, Range: 20 – 300Kg, Graduation: 0.5Kkg, Accuracy : +/-6.0Kg, Provides A Base For Sure Footing, A Large, Easy-To-Read Display And An Adjustable Hand-Grip Chain To Accommodate Height Differences.. Adjustable Chain, Accommodates Most Heights , Paraffin Wax Bath Heat Therapy Tub : Paraffin Bath Tub , Capacity : 5Kg, Power Plug : 220-240V 50/60Hz, Dimension:Internal S.S Tank Size: 40Cm X20cmx 20Cm., Heater: One Ring, 1000W , Heat Control: Thermostat To Control Temperature From 00 To 85 Degree, One Brush For Wax Application, One Mug, One Spatula, Aluminium Sheet Mesh For Heaters. , Human Skeleton Model : Pvc Alloy Material, Full Adult Size, Size : Height : 170 Cm, Height : 200 Cm (With Stand ) Weight: 15 Kg, Removable Arms And Legs, Breakage Free, Features Nerve Branches, Vertebral Artery And Hemited Lumbar Disc, Skull Includes Movable Jaw, Cut Caldarium, Suture Lines And Three Removable Lower Teeth, Mounted On A Sturdy 30Cm Wide Metal Base, Washable, Unbreakable Ideal For Teaching The Basics Of Human Anatomy , Interlocking Judo Matt : Made Of J.S.R( Japanese Synthetic Rubber), Size: 1Mtr × 1Mtr × 30 Mm, Judo Mat Density 200-250 , Deptt. Of Physics: , He-Ne- Lazer: 01Mw , He-Ne- Lazer: 05Mw , He-Ne- Lazer: 10Mw , Chemical Bath Deposition (Cbd) Instrument: The Set-Up Consists Of Following Units: Low Speed Light Duty Geared Stirrer, 1/20 Hp Ac/Dc Universal Motor,170 Rpm,S.S.Shaft With Chuck And Dimmer Stat Autovaries Speed Regulator.Cap.3-5Kgs With Stud & Backlit Assembly, To Hold Micro Slide Glass Digital Temperature Controller Model: Tc 544A, Selectron Make Display: 4 + 4 Digit, 7 Segment Digital Display, Timer: 0 To 9999 Min, Input: Fe-Con (J) / Cr-Al (K) Type Thermocouple, Range: 0 To 550°C, 1 Set Point, 230 V Ac Mains, 50 Hz, Crca Panel, Wiring & Temperature Sensor, Fe-Con (J) / Cr-Al (K) Type T/C, Max. Load: 2 Kw Heater Magnetic Stirrer With Hotplate Model: Ms203, Eltek Make / 2Mlh Remi Make Magnetic Stirrer, 2 Lit. Cap. Flask With Hot Plate Temp. Control, Step Less Speed Regulator & S.S.Body With Epoxy Coated Top Plate. Laboratory Jack (M.S.), Size: 8” X 8” Complete In All Respect , Thin Plates Thermoelectric Power Measurement Setup: Material:Mild Steel, Thickness: 0.1 Mm, Power: 50W, Display Type: Digital, Voltage230 V: Frequency 60 Hz , Electronic Spin Resonance And Nuclear Magnetic Resonance:Basic Unit Dimensions: 165X105x135 Mm3 Approx. Weight: 1.25 Kg Approx. Magnetic Coils Windings: 500 Each Magnetic Field: 0 - 3.37 Mt Connectors: Coaxial Power Connectors Dimensions: 20 Mm X 74 Mm Diam. Approx. Weight: 0.2 Kg Approx. Control Console Probe Input: 4-Pin Lemo Socket Coil Connectors: Saw Tooth Current Source, 0-250Ma, 50Ms, Pair Of Co-Axial Connectors Magnetic Output: Proportional To Coil Current, 0-1 V, Bnc Signal Output: Resonance Signal, 0-1 V, Bnc Socket Frequency Range: 45 To 75 Mhz Approx.(Esr) 10 To 15 Mhz Approx. (Nmr) Dimensions: 170X105x45 Mm3 Approx. Weight: 0.5 Kg Approx. Esr/Nmr Basic Set Includes A Basic Unit, Pair Of Coils, Control Panel & Plug-In Power Supply, 12 V Ac. , Potentionstat / Galvano Stat Instrument: (A)Potential Resolution: 1Mv (B)Potential Accuracy: +- 0.1% (C)Measured Current Resolution: 0.006% Ranges (A)Potential Range: +2~-2V(V) (B)Measured Current Range: 10-2~10-10 (C)Channels:2~10 Electrochemical Method (A)Cyclic Voltammetry (Cv) (B)Amperometry (It) (C)Open Circuit Potential (Ocp) Main Function (A)Multi-Channels With Individual Control Of 3 Electrodes System. (B)Multi-Channels Of Electrochemical , Operational Amplifier:(A)Potential Resolution: 1Mv (B)Potential Accuracy: +- 0.1% (C)Measured Current Resolution: 0.006% Ranges (A)Potential Range: +2~-2V(V) (B)Measured Current Range: 10-2~10-10 (C)Channels:2~10 Electrochemical Method (A)Cyclic Voltammetry (Cv) (B)Amperometry (It) (C)Open Circuit Potential (Ocp) Main Function (A)Multi-Channels With Individual Control Of 3 Electrodes System. (B)Multi-Channels Of Electrochemical , Digital Ph Meter: Range Ph Reading: 0 To 14 Mv Reading: -1250Mv To 1250Mv Solution Temperature: 0 To 100C Ambient Temperature: -40 To 70C (0C To 70C At Rated Accuracy) Resolution / Accuracy Ph Reading: 0.01 Ph 1 Mv Reading: 1Mv Solution Temperature: 0.1C 5 Ambient Temperature: +/- 2C 2 , Function Generator (1Mhz): Generator Frequency 1Mhz. O/P Voltage:1/10 Volt, Digital Display , Digitalvariable Power Supply 0-50Volt: Voltage 0-50Volt Current: 10Mv-1A Digital Display , Digitalvariable Power Supply 0-35V): Voltage 0-35Volt Current: 10Mv-2A Digital Display , Digital Multimeter: Hand Held Digital Multimeter With Four Display Digit With C Meter , (Dc+Acp-P) Power Chord, Two 30Mhz Oscilloscope Probes , Digital Storage Oscilloscope 100 Mhz: Signal Bandwidth : 100 Mhz Real Time Sampling:Max 1 Gsa/S Equivalent Sampling Rate: Max 50 Gsa/S 7.0 Tft Lcd Colour Display 2 Mpts Memory Depth , Rheostat 0-50 Ohm, 0-500Ohm, 0-1000Ohm: 0-50 Ohm, 0-500Ohm, 0-1000Ohm Cro (30Mhz): Bandwidthac 10Hz ~ 30Mhz (-3Db) Dc ~ 30Mhz (-3Db) Y Deflection 5Mv / Div ~ 20V / Div Rise Time <18Nsmag X 5 Accuracy : <5%Max Input400v(Dc+Acp-P) Sweep Mode Auto, Trig, Lock, Single Ac : 10Hz ~ 1Mhz -3Db Dc : 0 ~ 1Mhz -3Db Z Max. Input 400V , Resistance Decade Box 1-100K Ohm: , 8085 Microprocessor Kit : 8085 Microprocessor Training Kit Inbuilt Power Supply, 8085 Cpu Operating At 6.144 Mhz Crystal 8K Bytes Of Eprom Loaded With Powerful Monitor Program 8K Bytes Of Ram , Network Theorem Verification Kit (The Venin’S, Norton’S, Milkman’S,Maximum Power Transfer) , P-N Junction Diode Kit : 1) Vi Characteristics 2) P-N Junction Diode As A Wave Clipping Element , Zener Diodekit (Vi Characteristics) , Ujtkit (Characteristics And Application) , Scr Kit (Characteristics) , Study Of Amplifier Kit (Common Base/Common Emitter/Common Collector) , Jmfet Amplifier Kit (Characteristics) , Mosfet Amplifier Kit (Characteristics) , Multivibrators Kit (Actable, Bistable, Mons Stable Using Bjt) , Transistorized Oscillators Kit (Rc-Phase Shift, Wein Bridge, Hartley’S, Culprits) , Logic Gates Verification Kit (And, Or, Not, Nor, Nand With Ttl) , 7483 Bcd Adder Kit 7483 Binary Coded Decimal Adder , Binary Counters Kit Using Jkmsff , • Shift Registers Using Jkmsff Kit:74Hc 194 4-Bit Bidirectional Universal Shift Register. • Shift Registers Using Jkmsff Kit: 74Hc 198 8-Bit Bidirectional Universal Shift Register. , Multiplexer And De-Multiplexer Kit : (1:2, 1:4, 1:8, 1:16) Multiplexer (2:1, 4:1, 8:1, 16:1) De-Multiplexer , Counters Kit: (Synchronous, Asynchronous, Modulo N Decade) , Shift Registers Kit: (Sipo, Piso, Pipo, Siso) , P.A. System With Speaker, Mike And Collar Mike: Standard Company, Latest Version , Pa Mixer Amplifier 200 Watt With Integrated Digital Player (Bluetooth) And Wireless Microphone Connection , Wireless Professional Supercardioid Dynamic Microphone , Wired Dynamic Microphone With Cable And Stands , Collar Mic With 50-Meter Range , Cordless Gooseneck Microphone , Speaker 200W With Frequency Response :50-20000 Hz And Active & Passive Bluetooth With Stands Andtrapezoidal Enclosure Construction , Stage Monitor Speaker 200W , Teflon Lined Ss Hydrothermal Reactor 150Ml: Capacity-150Ml, Working Temp-2200C, Safe Temp. 2000C,Working Pressure:,3Mpa, Heating And Cooling Rate<5C/Min, Material: Shell Made Of High Quality Stainless Steel Inner Ptfe(Teflon Liner) Chamber , Deptt. Of Zoology: , Distilled Water Plant: Steel Distilled Water Apparatus With 5 Lit./Hr. Capacity , Shaking Incubator: I)Internal Volume: 215 Litreii) Platform Size: 580 Mm X 600 Mm Iii) Maximum Shaking :100Ml X 49,150Ml X Capacity (Volume X 49, 250 Ml X 33, 500Ml No. Of Flasks) X 24, 1000Ml X 15, 2000 Ml X 9 Iv) Shaking Speed Range: 20 To 250 Rpm V) Shaking Amplitude : 25 Mm Vi) Internal Dimensions : 660 X 765 X 650 W X D X H (Mm) Vii) Internal Dimensions : 800 X1150x1300 Wxdxh (Mm) Viii) Temperature Control : Microprocessor With Pt100 Sensorix)Display: 4 Lcd Screen, Large Size Display For Ease Of Reading X) Power Failure Alarm: Audio Visual Alarm Xi) Door Open Alarm : Audio Alarm In Case Door Open For Over One Minute Ii) Temperature Variation Alarm: Set Temperature ± 2°C, Audio Visual Alarm Xiii) Illumination: 8 Watts Fluorescent Tube Xiv) Internal Body Material: Stainless Steel – 304 Gradexv) External Body Material: Powder Coated Crca Steelxvi) Insulation (Cfc Free: 70 Mm Minimum For Body & 80 Mm For Door Polyurethane Foam)Xvii) Noise Level: Less Than 65 Db (A) , Laminar Air Flow (Horizontal) Mild Steel:Pre-Filter:99.00 % Down To 5 Micron Hepa Filter : Iso 14644 Class 5 (Class 100)99.97 % - 99.99 %Down To 0.3Micron Mesh Guard For Protection Of Hepa Filter Air Flow:Frontward Horizontally Noise Level:60 Decibel ± 5 % Velocity :0.35 – 0.50 M / Sec Work Table:Made Up Of Stainless Steel 304Gr. Cock For Gas On Work Table. Side Panels :6Mm ± 5 Mm Thick Acrylic Sheet. Front Door :Made Of Acrylic Uv Lamp:15/30 Wmake Philips Holland Illumination:20/40 Flourscent Tube Power Supply :230 V ± 10V /50 Hz Single Phase Cabinet : Made Of Mild Steel Duly Powder Coated Heavy Duty Blower : Dynamically Balanced With 0.25 Hp Electric Motor Mounted On Anti-Vibration Pad 1440 Rpm Motor Complete With Microprocessor Based Switches For Blower.Fluorescent Light And Uv Light With Lcd Back Light Display (Uv Light With Timer)Pressure : Digital Manometer 0.50 Mm Range With Filter Failure Alarm. Working Area Size:3’ X 2’ X 2’ , Colorimeter:Microprocessor Photo Colorimeter Model No. 1312 With 8 Glass Filters Covering Range Of 400- 700 Nm With Facility For Auto Concentration, %Transmission And Absorbance And K Factor Measurement. It Has 16X2 Line Lcd Data Display. Its Sample Holder Accommodates Glass Test Tubes Of 10Mm Path Length. Facility Has Been Provided For 100 Sample Data Storage And Interface For Any Centronics Printer. , Analytical Balance: The Brilliant Mono Tech Technology Sensormaximum Repeatability And Adherence To Uspoverload Protectionambient Condition Monitoring Perfect Self Automatic Calibrationprint Format Built-In Functioncapacity : 220Gmminimum Load : 10Mgreadability : 0.1Mgresponse Time : 2-3 Sec.Pan Size : 90Mm Dia , Dlp: Interactive Display Screen Size 75 Or Higher Resolution Uhd 3840 × 2160 Pixels Or Higher Brightness (Typical) 500 Nits Or Higher Contrast Ratio (Typical) 5000:1 Or Higher Response Time 4 Ms Or Better Light Life (Typical) 50,000 Hrs Or Higher Smart Eye Protectioninteractive Display Shouldhave Smart Eye Protection Hardness 4 Mm Tempered Ag Glass Or Better Anti-Glare Coating Interactive Display Should Have Anti-Glare Coating Touch Screen Touch Technology Infrared Touch Speaker Stereo Sound With In-Built 25 Watt X 2 Speakers And Subwoofer Of 20 Watt , Digital Photo Colorimeter: Range- 400-700 Nm, Filtre-8, Cuvete Size – 1 Ml • %T & Abs. • Display : 3 Digit Led • 1Ml Sample Volume • Light Source : White Led Eight Optical Filters On A Turret To Cover 400 – 700 Nm , High Speed Homogenizer:With 1/8 Hp Motor & Transformer Speed Regulator Suitable For Homogenizing Of Tissues At High Speed. Chuck To Hold Shaft Upto 50Ml Glass Homogenizing Cup With Rod Supplied As Standard. , Deptt. English , Cam Corder: Uvc Support Lcd/Evf Enhanced Visibility Usb, Type –C Usb Power Supply (Pd-Ei) Osd Recording Function 600 X Digital Sensor Size: 2.54 Cm Cmos, Autofocus System: Dual Pixel Cmosaf.Full Hd Recording Quality: Full Hd (1920X1080) 50 Pycc 420. , Deptt. Of Marathi , Pa System With 4 Speakers:Usb Amplifier - (Power Output 220 W Max., 160 W Rms At 10% Thd, 140W Rms At 5% Thd, 120W Rms At 2% Thd, Output Regulations 2 Db, No Load To Ful Load At 1Khz, Input Channels 5 - Mic 0.65 Mv/4.7%), 2 X Aux 100 Mv/470K, Frequency Response 50-15,000 Hz 223Db, Signal To Noise Ratio 60 Db, Tone Controls Bass: 710Db At 100 Hz, Treble 2210 Db At 10Khz, Output Ramp 200M V/6002, Line 1V/1Kil, Speaker Output, 42, 82, 70V And 100V, Digital Player Mp3, Player With Usb, Si) And Mmc Card Reader, Power Supply Dc: 24V (2 X 12V Car Battery) Ac: 220-240 V 50/60 Hz Power Consumption, Dc: 4A Ac: 300 Va. (In Set) Including Installation. , Collar Mic With 50-Meter Range , Television:138.8 Cm (55 Inch) Ultra Hd (4K) Led Smart Tv, Comprehensive Warranty:2 Yrs., Resolution: Ultra Hd (4K) 3840 X 2160 Pixels, , Deptt. Of Microbiology , Colorimeter:Digital Photoelectric Colorimeter With 8 Filters Lcd Read Out , Autoclave: Vertical, Size(30X50) With Basket, Spare Pressure Gauge, Rubber Gasket & Heating Coil , Hot Air Oven:(45X45x45) Cm, T.Range-5-250 Degree Celsius. Doubled Wall , Single Distillation Unit: Wall Mounted, Auto Cut Off, , Refrigerator: Side By Side Auto Defrost, 560-600 Lit. , Laminar Flow Bench: Ulpafilter, Iso Class 3 Work Zone, Low Noise At 52.4 Dba, Stainless Steel Side Wall, Internal Height: 2 Ft., Available Size: 4 Ft. , Incubator Bacteriological: Size(455X605x605)Mm,120Ltr. 5*To 70*Ambient Temperature, With Ss, 2 Shelves , Thermal Cycler :96 Well, Thermal Accuracy 35*C To 99.9*C,Dia.(44.5X24.5X21.5) , Adiwasi Girls Hostel , Setup & Installation Of Ip Dome /Bullet 2 Mp,1/2.8 Progressive Scan Cmos,Icr,Color 0.028 Lux @(F2.0:Agc On),0 Lux With Ir ,1920X1080:25Fps/30Fps (50/60Hz), 2.8Mm/4Mm Lens Fixed,H.265+/H.265/H.264/ Mjpeg, Dc12v &Poe, 3D Dnr, Blc, Roi, Hlc, Wdr, Ir Range: Up To 30M, Cloud Service. 3-Axis Adjustment, Rj45 Ethernet Interface, Line Crossing Detection, Intrusion Detection, Scene Change Detection, Audio Exception Detection, Face Detection, Ip67, Onvif (Profile S, Profile G), Isapi , Hard Surveillance Disk 6 Tb , Network Switch: 16 Port Network Switch Poe 16X10/100 Base-T Poe Port , 2 X Giga Rj45 , Network Switch:: 10 Port Network Switch Poe 8 X 10/100/1000 Base-T Poe Port, 2 X Giga Rj45 , Network Rack: 6U Network Rack With Standard Accessories , Pvc Junction Box , Metal Pole Clamp , Cat6 Cable (Rmt) , Cable Laying Charges (Rmt) , Conduit Pipe/Casing Patti With Pvc Clip Fitting (Mtr) , Setup,Installation ,Crimping ,Punching & Supervision Charges With One Year Warranty & Support , Deptt. Computer Science , N/W Multimedia Display Boards : Slim Digital Board Display 50” Hd And Nips High Quality Panels Commercial Grade Panels For 24/7 Usage Battery Power Multiple Usb Input Option – Usb ,Sd ,Hdmi Etc Built In Operating System With Wi-Fi And Sim Card Input Option High Brightness ( Sunlight Readable) Colour Coded Frame , Light Weight And Portable , Ups 500 Va:10Kva :Type: Online Ups 3 Phase In 3 Phase Out, Rating In Va: 10Kva, Battery Module: External Battery Module, No’S Of Battery: 20 Nos Of Batteries, Battery Type: Smf – Vrla, Dc Voltage:240 Vdc , Vacuum Cleaner:Wd X2 Wet And Dry 1300 Watts, 22.5 Kpa High Power Suction Vacuum Cleaner | Blower Function | Dynamic Dial Power Control | Auto Clean | 13 Accessories , Psychology , Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) , Home Theatre:7200Watt, Dimension 16.93X1.93X8.27, Play Back Capacity, Weight 5.0716 2D-3D, Conversion Wi-Fi, Built In 2.4 Ghz, Input , Dlp Projector: Native Resolution —Wxga (1280X800) Or Higher. Brightness 4000 Ansi Lumens Or Better. Throw Long Throw, Keystone & Corner Correction - Projector Should Have Both Vertical (300) And Horizontal (200) Keystone Correction And Four Corner Adjustment, Minimum Lamp Life-15000 Hours In Economy Mode Input Ports- Hdmi-1, Vga-I. Audio In, Video X1 Other Ports-Rs 232, Lan (Rj45). Output Vga, Audio Out. Contrast Ratio- 22000:1 Or Better, Optical Zoom -1.1X, Throw Ration-1.55-1.70 Or Better, Special Features-Usb Reader. Data Over Lan. In-Built Speaker —Minimum 20 Watts Rams To Deliver Full Range Sound 20Hz-20Khz, Input Power Supply —As Per Indian Standard With Compatible Power Cable And Connector Accessories. All Device And Cable For Connecting With Computer. Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control, Otheraccessories —Cable9of 2 Meter Length Hdmi,Power0 Should Be Supplied Along With Projector, Bisregistration — Quoted Mode Of Projector Should Have Valid Bis Registration Make-Globus , Engineering Section (St-554) , Multifunction Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wifi Network, Machine Type A3, Monochrome Laser Mulification, Multiple Copies: Upto 9999, 2Gb Ram, 2 Cassette, 01 Byepass Tray, Duplex Print, Colourtouch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model Withstabilizer &Trolly.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , P.G.T.D. Of Physical Education , Dlp: Interactive Display Screen Size 75 Or Higher Resolution Uhd 3840 × 2160 Pixels Or Higher Brightness (Typical) 500 Nits Or Higher Contrast Ratio (Typical) 5000:1 Or Higher Response Time 4 Ms Or Better Light Life (Typical) 50,000 Hrs Or Higher Smart Eye Protection Interactive Display Shouldhave Smart Eye Protection Hardness 4 Mm Tempered Ag Glass Or Better Anti-Glare Coating Interactive Display Should Have Anti-Glare Coating Touch Screen Touch Technology Infrared Touch Speaker Stereo Sound With In-Built 25 Watt X 2 Speakers And Subwoofer Of 20 Watt
Contract Date: Aug 25, 2025 Contract Value : 59.16 Lakh
Boards / Undertakings / PSU No of Bidders 18
Maharashtra View Result →
46.
Public Administrative Department #7670487 AOC
Construction And Development Of Working Women Hostel At Chikalthana, Weekly Market Gut No 410, Chhatrapati Sambhajinagar- 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) 2 Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means 3 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 4 Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical Means 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steelcentering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 6 Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. 7 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete 8 Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) 9 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 10 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 11 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 12 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 13 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 14 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 15 Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 17 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc.complete. 18 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 19 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints,watering and scaffolding etc. Complete 20 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 21 Providing and fixing precast R.C.C. frames of door/windows/ ventilators of c/s 125mm X 50mm with 2 bars of 8mm dia. Of steel as r/f . In half brick wall 22 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 23 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. 24 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) 25 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box. 26 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc 27 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete 28 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. 29 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 30 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 31 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 32 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or a directed etc. complete. 33 Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 34 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete 35 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity above 1000 to 20,000 litres 36 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 37 Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 38 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete 39 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 40 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. 41 Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete 42 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. 45 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 46 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete 47 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd A1/259) 48 Lift 0 to 1.5 M Cum 140.00 140.00 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-2/259) 49 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-4/259) 50 Providing ISI standard stoneware pipes including all taxes inspectin charges, railway freight, unloading, transoport, stacking,complete.150mm dia. SWG pipe 51 Louvering and jointing in proper grade, alignment standard stoneware pipes with cement joint 1:6 C.M. proportion including unloading, transoport, stacking, necessary excavation and jointing complete. 150mm dia. SWG pipe 52 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 53 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR.Item no. 35.21) 54 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) 55 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 56 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. 57 Transportation of surplus material from work site to any disposal place as directed by Er.incharge eith a lead of 5km including and stacking completed. 58 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. 59 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. 60 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi- strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surfaceand nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated,Hex head, self-drilling screw etc. complete. (weight of profile 61 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 year guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete 62 Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish 63 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 64 Providing, applying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealent, backer rods etc. overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre) 65 Providing and preparing kitchen otta up to 75 cm width, made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. 66 Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete 67 Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick (minimum) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings, fixtures, smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) 68 Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.One Number: As directed by Engineer- in-charge. 69 Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mm dia G.I. pipe ( Rezan/ concentiDeleted ire 0.75 mm dia ) with hot dip and G.I. coated hooks as per drawing supported on M.S. angle 50 x 50 x 6 mm at 2.5 mtr. c/c including fixing and fastening with wire, painting M.S. angles with one coat of red lead primer and two coat of oil paint etc. complete. 70 Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method ( excluding reinforcement) approved by Engineer-in-charge. 71 Single Bed @ 2025LX 1000DX 650HProviding and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm.Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side laminate 72 Bed Side Table @ 400LX 400DX 415HProviding and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding 73 Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required. 74 Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery 75 NOMAD Interactive Screen: Providing and Fixing NOMAD Interactive Screen with storage. Specification size : 1260L X 500D X 1800H. Prior approval of Engineer in charge in necessary. 76 Providing & Arrangemnt of MId Back, Normal SyncroMechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery. 77 Café Chrome 6 Seater Canteen tableSpecification : 1800L x 900D x 750H. Prelam Hydroshield Top with MS Understructure in Chrome finish 78 Tango Cafeteria Chair* Stackable Chairs* Without Arms* One Moulded Unbreakable Chair* Available Colors - White, Black, Green, Yellow, Red. 79 Double Bed (Compact 2 Nos.) Specification : 1980L X 900D X 450-750HMade inPrelam board with understorage 80 Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. 81 Sofa Set 3+1+1Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat 82 4 Seater Dining TableSpecification : 800L x 800D x 750H.Prelam Hydroshield Top 83 Stool for Lab and Class-IVProviding and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 84 Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 85 Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery. 86 Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. 87 Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. 88 Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 89 12 Seater Reading Table for Library @3600Lx1200Dx750HTProviding and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. 90 Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. 91 Library Area Table @ 1350Lx750Dx750HTProviding & Fixing of FREE STANDING TABLE @ 1350Lx750Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, BENT LEG to be CHROME FINISH as per drawing. 92 CHILDREN TRIANGLE TABLESize: 1300L x 1300LX1300L x 400H Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 93 CHILDREN CHAIR Size:400LX 400L Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 94 CHILDREN SHELF Size:2560LX 400D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support:End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 95 Executives Table @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing. 96 CHILDREN CRIB Size:1000LX 650D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 97 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 98 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 99 Supplying and erecting PVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX(1-2-11) 100 Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 101 Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 102 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 103 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 104 Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 105 Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 106 Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 107 Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 108 Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 109 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 110 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 111 Supplying and erecting modular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.(1-6-10) 112 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 113 Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.(1-6-23) 114 Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.(1-6-24) 115 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. 116 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. 117 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12module duly erected. 118 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 119 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 120 Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW(1-7-26) 121 Supplying and erectingLED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 122 Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 30 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 123 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 124 Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.(2-1-16) 125 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 126 Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt,CRI>80, CCT of 6500K and THD<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty.(2-1-22) 127 Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.(2-3-13) 128 Supplying and erecting Electronic type cordlesscallbell erected on T.W.board havingportablebellpush working on 9V D.C. battery and(effective range upto 45 meter) bell on 250 V A.C. supply.(2-3-15) 129 Supplying and erecting integrated LED Highbay Fitting70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 130 Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.2(-10-13) 131 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF(2-10-22) 132 Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 133 Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.(2-11-6) 134 Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC(3-3-9) 135 Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)(3-5-1) 136 Supplying, installing, testing and commissioning of3 kVA capacity online pure sine wave with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS(3-7-3) 137 Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-9) 138 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-6) 139 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-8) 140 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP(9-1-1) 141 Supplying, erectingandmarking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-2) 142 Supplying, erectingandmarking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-3) 143 Supplying, erectingandmarking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-10) 144 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 145 Supplying and erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB(5-4-1) 146 Supplying&erectingtriplepoleand neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB 147 Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), withdoor, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 148 Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW SWR/MCBDB(5-4-9) 149 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 150 Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 151 Supplying, Erecting and Commissioning of4 pole RCCB 40A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB(5-6-5) 152 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 153 Providing and erecting 4 Pole MCCB,100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB(5-5-1) 154 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 155 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 156 Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete.(6-1-1) 157 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 158 Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard(6-1-20) 159 Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB 160 Supplying and erecting panelmountingtypedigital ammeterhavingthreeandhalfdigitLEDdisplay, externalCToperated,calibratedfor suitable to operate on 500V, 0 to 1000Ahaving accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs andmounting hardware on provided panel complete with calibration certificate from manufacturer.(6-3-7) 161 Supplying and erecting panelmountingtypedigital voltmeterhavingthreeandhalfdigitLEDdisplay, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5,AC supplywithnecessaryPVCwireleadsandlugsand mountinghardwareonprovidedpanelcompletewith calibration certificate from manufacturer.(6-3-8) 162 Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panelmounting to measures and displayparameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I,kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software(6-3-19) 163 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. 164 Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on providedbox / panelwith necessary material, wiring & connections etc.(6-5-5) 165 Supplying and erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.(6-5-6) 166 Supplying and erecting 50 kVAr,3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 Vand having minimum overcurrent capacity of 1.8 In,peak inrush current capacity 300 Inand minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC 167 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 168 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 169 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-31) 170 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 171 Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete(1-6-15) 172 Supplying & erecting20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW 173 Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW 174 Supplying, erecting & commissioningMDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW 175 Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW 176 Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW(1-9-18) 177 Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of6 x 32 extensions suitable upto 96 extensions complete. 178 Supplying, Erecting and Commissioning ofpush button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.(1-9-29) 179 Supplying, Erecting and Commissioning ofIP telephone instrument as per specification complete.(1-9-30) 180 Supplying and erecting unbreakable concealed typemodular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-6-34) 181 Supplying and erecting 20m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. 182 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC(1-10-1) 183 Supplying and erecting LSZH armoured multimode Optical Fibre Cable with 24 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC 184 Supplying and fixing1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-17) 185 Supplying and fixing3 m UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-20) 186 Supplying, fixing, and configuring24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS(1-11-4) 187 Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL 188 Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.(1-12-1) 189 Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO 190 Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP 191 Supplying and fixing9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK(1-12-18) 192 Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension: 1020 x 846 x 1840 (mm), Input power: 6.02 kW, 400 V, 3 Ph, 50 Hz, Output power: 19.8 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, centrally controlled operation, operational noise level: 65 dBA with necessary accessories complete with 5 years ON-SITE warranty. 193 Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 5000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricatedwith 6 mm thick plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2 BSP forprovision toinstall6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. 194 Supplying,erecting, testing and commissioning of10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) havingminimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hzincoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V ACat each socket with 3.5TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mmduly RAL7035 Coated M.S, Erected oniron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification. 195 Supplyinganderecting Biometric Access Control System working on 230V A.C. supply with resetting arrangement complete erected 196 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 197 Supplying, fixing, and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS(5-3-25) 198 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 199 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-27) 200 Supplying and erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE(7-6-2) 201 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 202 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 203 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 204 Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 60 to 170 LPM discharge at 97 to 30 m head & discharge & delivery pipe of Size-40 mm diameter with a necessary H type clamps as per specification No. WP-SMP 205 Supplying and erecting minimum Three & above star rated submersiblepump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP(12-3-2) 206 Supplying and erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P.(12-4-2) 207 Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-8) 208 Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-9) 209 Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.(12-4-15) 210 Supplying and erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .(12-4-17) 211 Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(16-1-5) 212 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 213 Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.(16-5-6) 214 Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete.(16-5-18) 215 Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.(16-6-15) 216 Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.(16-6-21) 217 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 218 Supplying, installation, testing and commissioning extendable/non-extendable indoor type 11 kV, 630A,load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundations per specification no SW-HTS / LBS 219 Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982(6-1-16) 220 Supplying,erecting,testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation. 221 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 222 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 150 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 223 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 224 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 225 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 226 Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ(8-1-13) (11 mtr x 2 Pole =22) 227 Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.(8-3-17) 228 Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI 229 Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN 230 Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA 231 Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. 232 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9- 1-1) 233 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 234 Supplying, installing, testing & commissioning 3 phase,11/0.433 kV,50 Hz., 250 kVA, Mineral oil immersed and naturally cooledoutdoor type, Copper wound, without gas cushioning , hermetically Sealedtransformer, delta/star connected with additional neutral brought out on load side, temperature rise should not Exceed 45℃ by thermometer in oil and 50℃ by the resistance methodin winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 980 Watts at 50% load, 2930 Watts at 100%load as perIS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL 235 Supplying and erecting11 kV outdoor type gang operated airbreak,triple pole switch 400 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channels on providedcrossarmwithadequate length of C class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. 236 Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fusebarrelwithmetalfitting,fuse elementmounted onM.S.channel with working currentof15A capacity complete erected on provided cross arm. 237 Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG(10-6-18) 238 Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.(10-6-19) 239 Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD(10-6-20) 240 Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). 241 Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete.(10-6-22) 242 Providing pair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete.(10-6-23) 243 Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)(10-6-24) 244 Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV 245 Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544duly tested, with necessary test certificate from manufacturer.(10-6-28) 246 Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. 247 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 248 Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. 249 Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal,45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)(16-3-4) 250 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 251 MSEDCL Charges 252 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 253 Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.(5-11-19) 254 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 255 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 256 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 257 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspectoras per specification no. GEN-DG 258 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 259 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 260 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 261 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV(1-3-14) 262 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 263 Supplying and erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation.(5-2-5) 264 Supplying, erectingandmarking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-1) 265 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 266 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 267 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 268 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT(8-2-21) 269 Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 270 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 271 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 272 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 273 MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 274 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 275 Supplying, installation, testing and commissioning of booster fire pump[BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of7.5 kW or of suitable kW capacityfor manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP 276 Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP 277 Supplying and erectingG.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP 278 Supplying and erectingG.I. pipe‘C’ class ERW65 mm dia with necessary fittings complete asper specification no. FF-PP 279 Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP 280 Supplying and erecting G.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-6) 281 Supplying and erecting G.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-7) 282 Providing G.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-8) 283 Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system.(13-6-10) 284 Supplying and erecting 100 mm dia cast iron foot valve ball type/flap typewith strainer for negative suction complete asper specification no. FF-VL/FV(13-7-2) 285 Supplying and erecting 100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-14) 286 Supplying and erecting 150mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-15) 287 Supplyinganderecting200mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV 288 Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV(13-7-24) 289 Supplying and erecting 25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV(13-7-32) 290 Supplying and erecting stainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV(13-7-35) 291 Supplying and installingone piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000litres fitted with necessary accessories complete asper specification no. FF-FFA/PT(13-8-1) 292 Supplying and installingwall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV(13-8-2) 293 Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL(13-8-4) 294 Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ(13-8-8) 295 Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC(13-8-11) 296 Supplying and erecting 300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT(13-8-12) 297 Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV(13-8-13) 298 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG(13-8-14) 299 Supplying and erecting 12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS(13-8-15) 300 Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer diawith required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP(13-8-16) 301 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valveof size ( 400 x 400 x 400)mm or hose pipe boxof size (600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mmhaving front doors with viewing glass of size (200x150) mmandlockingarrangement with necessary fixingmaterialsuch as rubber biddingetc. dulypainted in post box red colour( Code 538 of IS 5)(13-8-18) 302 Supplying and erecting M.S./CRCA cabinet forhousing FireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6) andlocking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)(13-8-19) 303 Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½) dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. 304 Supplying, erecting, testing and commissioning ofvane type water flow detector75/80 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.(13-12-2) 305 Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.(13-15-1) 306 Supplying, installing, testing and commissioning ofmanual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP(13-9-7) 307 Supplying, installing, testing and commissioning ofhooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR(13-9-8) 308 Supplying, installing, testing and commissioning ofFRLSXLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU(13-9-10) 309 Supplying, installing, testing and commissioning of2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP(13-9-14) 310 Supplying, erecting, testing and commissioning of120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR(13-11-1) 311 Supplying, erecting, testing and commissioning of15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC(13-11-2) 312 Supplying, erecting, testing and commissioning ofstand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC(13-11-3) 313 Supplying, erecting, testing and commissioning ofrust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete.(13-11-4) 314 Supplying, erecting, testing and commissioning ofrust free microphone table stand of chrome plating/powder coating or S.S. material,up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.(13-11-5) 315 Supplying, erecting, testing and commissioning of2 core shielded cable complete asper specification no.FF-PA/MCC(13-11-6) 316 Supplying, erecting, testing and commissioning of1.5 sq. mm speaker wire complete.(13-11-10) 317 Supplying, installation, testing and commissioning of 220/250Volts, single phase, 50 Hz Siren of 3.25 km range (Diametrical),horizontaldoublemountingtype of0.5 HP 6000 RPMon C. C.foundation complete as per specification no. SRN-AS/SM 318 Supplying and erecting ABC powder type fire exitinguisher as per IS: 13849/15683 of 6 kg capacity with necessary clamp for erection on wall (Non-CSR) 319 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fire signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 300 mm X 100 mmas per IS 12349-1988 320 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fir signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 450 mm X 100 mm as per IS 12349-1988 321 Providing and fixing of Emergency Exit Lights LED Beam-II with exit high glow LED White lamps working on battery 12 V 7.6 Ah for duration 4-5 hours (approx) wattage of LED lamp is 26 watt each 2 Nos. of lamp total wattage 52 Watts Weight of unit will be 5.4 kg input voltage 220 V AC 50 Hz Output Volatge 12 V DC the outer cabinet is powder coated, for safety purpose DC & AC fuse system is given in unit as per IS 9583-1981 322 Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 323 Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 324 Supplying and erecting 20mm dia. corrugated flexiblepolypropylene conduit 325 Supplying and erecting 10m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.. 326 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC 327 Supplying, fixing, and configuring 24 ports, POE switch in provided rack as perspecification No. WG-NWC/ENS(1-11-3) 328 Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. 329 Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA 330 Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK 331 Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 1 hrs. PWM & IGBT based,with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS 332 Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-12) 333 Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM. 334 Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM 335 Supplying, installing, testing & commissioning of 64/80 Ch Network VideoRecorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 MegapixelResolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided,Atleast one HDMI output of 4K resolution, atleast one VGA output with outputup to 1920 × 1080,Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power,Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANRTechnology,8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptiveEthernet interface,support multi brand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging andprogramming etc. complete as per specificationss no. CCTV-NVR 336 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Portof NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected inposition in provided NVR as per specification no. CCTV-HDD 337 Supplying & erecting 43 professional LED display with 1920*1080 (FullHD) Display, suitable for 16/32 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand andwiring connections etc. complete as per specifications no. CCTV-MON 338 Supplying and erecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON(1-2-3) 339 Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-5) 340 Supplying, installing, testing and commissioning of15 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 45 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnectingwires / cables up to solar ON GRIDinverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 yearsincluding net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG(4-5-4) 341 Supplying and erecting switch disconnector fuse (SDF) switch 415V up to 63A, open execution, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3HRC - DIN type fuse,insulation voltage 1000 Vfor enclosing in panel with rotary handle for ON / OFF operation (without HRC fuse)(5-1-17) 342 Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A(5-10-26) 343 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 344 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark,accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh andMD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power &with transparent hinge type box completeerectedonpolished teak woodboardduly wiredwithrequiredsizeof weather proofPVC wires duly testedby electric supply company.(6-3-3) 345 SupplyinganderectingAC three phase HT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz,with backlitLCD display, optical port& RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. 346 Supplying, installtion & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested forImax 40 kAfor three phase and neutralwith compliance to IEC 61643-11 as per specification no. CP-SPD(6-6-6) 347 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-33) 348 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 349 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-2) 350 Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.(9-2-1) 351 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 352 Supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete.(9-3-1) 353 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 354 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 355 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 356 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 357 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.(1-6-29) 358 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 359 Supplying, erectingandmarking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-7) 360 Supplying, erectingandmarking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-13) 361 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 362 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 363 Supplying, fixing, and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO(5-6-13) 364 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-9) 365 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-33) 366 Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI(9-1-5) 367 Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete.(9-2-4) 368 SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mmhigh· Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high· Lift shaft available having clear size of .1900 mm wide x 1900 mmdeep, 1500 mm Pit depth, 4250 mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.13) 369 SITC of Electric Traction Passenger cum Stretcher/Hospital Liftwith · Rated capacity :- 15 Passenger/1020Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL [applicable for PassengerLift with MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x2000mm high· Clear Car size of 1000 mm wide x 2400 mm deep x 2250mm high· Lift shaft available having clear size of 1800 mm wide x 3000 mmdeep,1500 mm Pit depth, 4250 mm Overhead· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.17) 370 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 371 For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 372 Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC(1-1-9) 373 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 374 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 375 Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TRcapacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 376 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. 377 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. 378 Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 379 Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 380 Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 381 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 382 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 383 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 384 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 385 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 386 Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers, filters at position complete. 387 Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 388 Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODUs can be controlled and up to 992 IDUs can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. 389 Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. 390 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 391 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. 392 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 393 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-94) 394 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-95) 395 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-96) 396 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 397 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 5000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 398 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 3000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 399 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 2500 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 400 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 401 Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. 402 Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PVC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system. 403 Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC 404 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 405 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 406 Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO 407 Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-2) 408 Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-3) 409 Supplying and erectingGI sheet 1.25 mm (18 SWG)having zinc coating of 350 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. 410 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 411 Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 412 Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
Contract Date: Jul 31, 2025 Contract Value : 16.94 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
47.
Power #7619504 AOC
Tender For Construction Of220/132 Kv, 1X160 Mva Gss At Dalot (Upg.) [Distt.- Pratapgarh]Including Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning - MAIN MATERIAL/ ITEMS 2 Auto Transformer: 3 220/132kV, 160 MVA AutoTransformer with all accessories (excluding transformer Oil) as per technical specification 4 Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above 5 Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers at S-I (1) above 6 Circuit Breakers 7 220 kV Circuit Breakers 8 220kV circuit breakers (3 Ph.) Along with support Structure 9 2500 A, 50 kA 10 132 kV Circuit Breakers 11 132 kV circuit breakers (3 Ph.) Along with support Structure 12 1250 A, 40 kA 13 Instrument Transformers 14 Capacitor Voltage Transformer 15 Single-Phase, 220 kV, 4400 pf CVT 16 Current Transformer (1-Phase) 17 220 kV CT 18 1000/1 A, 5C 19 132 kV CT 20 1000/1 A, 3C 21 C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II) 22 New Substation 23 Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB 24 Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB 25 Control Panel for 220 kV Feeder Type: SAS-FCB 26 Relay Panelfor 220 kV Feeder Type: SAS-FRB 27 Control Panel for 220 kV Bus Coupler Type: SAS-BCCB 28 Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB 29 220 kV Busbar Protection Relay Panel Type: SAS-BBRB 30 Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB 31 Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB 32 Station HMI [Industrial grade Computer with 21TFT monitor as per specification requirements] 33 Station HMI (Hot Standby)[Industrial grade Computer with 21TFT monitor as per specification requirements] 34 HMI View Node[Industrial grad Computer with 21TFT monitor as per specification requirements] 35 A3 Size B&W Laser Printer 36 Substation Automation System Network Panel Type SAS-NW 37 Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC] 38 Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired 39 Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification. 40 Substation Auxiliary Monitoring Panel Type SAS-SAMP 41 Other Items: 42 Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements. 43 Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards. 44 Surge Arresters 45 220 kV LA 46 132 kV LA 47 Batteries & Battery Charger 48 Batteries (Sizing shall be as per requirement of technical specification) 49 220 V [Min. 600 AH] 50 48 V [Min. 600 AH] 51 Battery Charger System 52 220 V Float and Boost 53 50 V Float and Boost 54 Lighting System 55 Outdoor Lighting & other Works 56 Lighting Fixture Type FL-1 57 Lighting Fixture Type FL-2 58 Outdoor Receptacle 59 Type-RP 60 Type-RO 61 Substation Premises Lighting 62 Lighting poles 63 Type-L1 64 Type-D1 65 Street Lighting Type-SL-L1 for mounting on poles 66 Street Lighting Type-SL-D1 for mounting on Poles 67 Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc. 68 Lighting PanelType ACP-2 as per technical specification 69 Lighting PanelType ACP-3 as per technical specification 70 Indoor Lighting & Other Works 71 Electrification 72 Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room,Hall and administrative office building as per the requirements of the specifications 73 Illumiation 74 Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories andmounting arrangements) 75 Indoor Lignting Panels 76 Lighting Panel (Indoor)Type ACP-1 as per technical specification 77 Lighting Panel (Indoor)Type DCP as per technical specification 78 Wall mounted fans Approx. 400 mm sweep 79 Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator 80 Exhaust Fans 81 Fire Fighting System 82 Nitrogen Injection Fire Protection System for Auto Transformer (160 MVA ) complete in all respects. 83 DCP Type 84 i) 5 Kg. 85 ii) 10 Kg. 86 Carbon di oxide type – 6 Liters. 87 Foam Type- 9 Liters 88 Sand type 89 i) GI Buckets 9 liters capacity 90 ii) Steel Stands for four buckets 91 Air Conditioning System 92 Air Conditioning for the Rooms specified in the specifications 93 1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building] 94 Control Cable (PVC) 95 4 CX4 Sq. mm 96 19Cx2.5 sq.mm 97 Substation Structures 98 Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]: 99 Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements] 100 Isolators 101 220 kV (3-Phase) (Horizontal DOUBLE BREAK) 102 1600A, 50KA, isolator with one E/S 103 Post insulators for above Isolator 104 1600A, 50KA, isolator with two E/S 105 Post insulators for above Isolator 106 1600A, 50KA, isolator without E/S 107 Post insulators for above Isolator 108 1600A, 50KA, isolator without E/S (TANDEM Type) 109 Post insulators for above Isolator 110 132 kV (3-Phase) (Horizontal DOUBLE BREAK) 111 1250Aisolator without E/S 112 Post insulators for above Isolator 113 Switchyard Erection 114 Busbar & Interconnections 115 New Substation/ Switchyard 116 220 kV Switchyard Works: 117 Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/PorcelainLong Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 118 Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 119 Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 120 220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 121 Twin ACSR Zebra 122 Single ACSR Zebra 123 Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps,connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following: 124 220 kV DMT-type layout 125 Line bay 126 Transformer bay 127 Bus-Coupler 128 Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps,connectors, junction box including of all accessories etc. 129 132 kV Switchyard Works: 130 Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 131 Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 132 132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay),Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 133 Twin ACSR Zebra 134 Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV TransformerBay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps,connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following: 135 132 kV Main & Aux-type layout 136 Line bay 137 Transformer bay 138 Bus Post Insulators (BPI) 139 220 kV 140 132 kV 141 Earthing & Lightning Protection System 142 Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area 143 28 mm Dia MS Rod 144 50X12 mm GS Flat 145 Earth Enhancing Compound for treated pits as above and other requirement as per specification 146 Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat 147 Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats 148 Earth Wire for Shielding Protection of Switchyard 149 7/3.15 Galvenized Steel Wire 150 Earthwire tension clamps with D Shackle assembly 151 PG calmp to suit 7/3.15 mm GS earth wire 152 Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat 153 Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat 154 Lug to suit 7/3.15 mm earth wire 155 Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire 156 GI Channel 100x50x6 mm 157 Bay Marshalling KIOSK 158 200 way (Stud Type Connectors) 159 AC Distribution Boxes (Outdoor Type) 160 Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building] 161 Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washersetc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works] 162 LT Switchgear 163 220VDCDB 164 48V DCDB 165 PLCC EQUIPMENTS 166 220 kV Wave trap (2000A, 0.5 mH, 40 kA) 167 SSB single Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set. 168 A.F. Protection coupler microprocessor based suitable for Four commands. 169 Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level. 170 HF Armoured Coaxial cable having 75 Ohms unbalanced impendance. 171 Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility 172 Telephone Sets (Push Button Type) 173 5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm 174 5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm 175 TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS 176 (A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements] 177 Insulation Tester (5000 Volts, Digital) 178 SF6 Leakage Detector 179 Digital Multimeter 180 Digital Clamp Meter 181 PLCC Maintenance/Testing Equipments: 182 200Hz to 620KHz selective level meter including impedance return loss measuring attachments compatible with level generator (at sl.ii below) 183 Level generator with a range at 50Hz to 620kHz including facility for synchronization with SLM 184 8 digit time interval & frequency counter with the frequency range of 10 Hz to 10MHz & timer range of 1 microsec to 1 sec in decade steps. 185 Dual range 15 MHz oscilloscope with a display screen 8x10 sq.cm and the input impedance of 1 M ohm/25 pF with a deflection coefficient of 5Mv/div to 20 V/div. 186 4-1/2 digit LCD Multimeter with input impedance of 10Mohm & with a range of 0.1 mV to 1000 V DC, 0.1mV to 600v AC, 0-10 AMP AC,(40hz to 10KHz) & 0-20 Mohm With builtin power –supply. 187 Print testing Kit for PLCC terminal, protection coupler, EPAX , As per specifications appended at Annexure- V2-P3-S19-2, Volume-II, Part 3, Section-XIX 188 (B) Maintenance Tools& Tackles 189 Oil Sampling Bottle (1 Liter Capacity) 190 Vaccum Cleaner 191 Telescopic ladder aluminium 6 meter height 192 Ring spanner set 193 Tube spanner set 194 Pipe wrench 24 inch 195 Pipe wrench 18 inch 196 Hydraulic crimping tools up to 630 sq.mm 197 Threading die set for pipe threading 198 Welding machine (arc welding) 10kVA 199 Heavy duty drilling machine 200 Bench Vice 201 Insulated cuttingplier 12 inch 202 Insulated cuttingplier8 inch 203 Screw driver 18 inch 204 Screw driver 12 inch 205 Hammer 8 lbs 206 Hammer 2 lbs 207 Chain pulley block 5 ton 208 Pipe derrick 209 Allen Keys 210 Box Spanners 211 (C )Office and Miscellaneous Equipments/ Items 212 Insulation Rubber mat (1mX2mX 12 mm) 213 Isulation Rubber Gloves (15 kV Tested) 214 Furniturefor Control Room Building: 215 SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification 216 Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet) 217 Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet). 218 Library Shelf with Glass Door (min 4 Shelf) 219 Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane. 220 Archival Storage 4 Drive Type 221 Lateral Filing Cabinets 222 3 Drawer Unit 223 4 Drawer Unit 224 Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 225 Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 226 Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system. 227 Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage). 228 Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG. 229 Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage 230 Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round. 231 Key board (wooden) with Glass door 232 First Aid Box 233 Shock Treatment Chart [Laminated with Frame] 234 Safety Instruction Boards [ Laminated with Frame] 235 (D) Drinking Water Arrangement 236 Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr) 237 RO/ Water Purifier 238 Refrigirator (380 Lt.) 239 Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner] 240 Danger Plate [Size and Color etc. be got approved from owner] 241 MANDATORY SPARES 242 (A) 220/132 kV TRANSFORMER 243 Bushing with metal parts & gaskets of each rating including Neutral bushing 244 Local and remote winding temperature indicator complete with sensing device & contacts 245 Oil temperature indicator with contacts & sensing device 246 Oil cooler pump with motor 247 Cooler fan with motor 248 Set of starter, contactor, relays and switch for electrical control panels (1 set of each type and range) 249 Buchholz relay complete with floats & contacts 250 (B)Circuit Breakers 251 220 KV 252 (One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism. 253 Rubber gaskets, ‘O’ rings and seals 254 Fixed Contacts 255 Moving Contacts 256 Terminal pads and connectors 257 Closing Assembly Valve 258 Trip Assembly Valve 259 Auxiliary Switch Assembly 260 Operation Counter 261 Closing Coils 262 Tripping coils 263 Support insulator complete for one pole of breaker 264 145 kV 265 One pole of circuit breakerwithout support structure and operating mechanism. 266 Rubber gaskets, ‘O’ rings and seals 267 Fixed Contacts 268 Moving Contacts 269 Terminal pads and connectors 270 Closing assembly valve 271 Trip assembly valve 272 Auxiliary switch assembly 273 Operation counter 274 Closing Coils 275 Tripping coils 276 Support insulator (set complete for one pole of breaker) 277 (C) Instrument Transformer 278 Spare of 245kVCapacitive Voltage Transformer 279 (i)Complete CVT 280 Spare of 245kVCurrent Transformer 281 (i)Complete CT [1 No. each type supplied) 282 Spare of 145kVCurrent Transformer 283 (i)Complete CT (1 No. each type supplied) 284 (D) C&R panels (similar items as used in the quoted panels) 285 Bay Control Unit (220 kV Side of offered type) 286 Bay Control Unit (132 kV Side of offered type) 287 Bay Unit (For 220 kV Busbar Protection of offered type) 288 Bay Protection Unit (Distance for 220 kV Feeders of offered type) 289 Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type) 290 Bay Protection Unit (Distance for 132 kV Feeders of offered type) 291 Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I) 292 Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II) 293 Self reset trip relay 294 Hand reset trip relay 295 Timer relay 296 DC supervision relays 297 Flag relays 298 Auxiliary relays 299 Multifunction Panel Meter 300 Fiber Optic Cable with Connectors 301 Transducers (Each Type used in the autoamtion system) 302 Ethernet Switch (of offered type) 303 (E) Surge Arrester 304 220kV class 198 kV rating LA complete as specified. 305 132kV class 120 kV rating LA complete as specified. 306 2 Nos. Terminal connector of each type as spare 307 (F) Battery & Battery Charger 308 220 V& 48 V Type Battery 309 Spare battery cell without electrolyte 310 Terminal connectors with bolts & Nuts 311 Float level indicators 312 Vent Plugs 313 220V/ 50V Battery Chargers 314 Set of Control Cards 315 Set of relays 316 Set of contactor 317 Micro-switches 318 Filter Capacitors 319 Thyristor/ Diode 320 Set of switches 321 Set of wound resistors 322 Potentiometers 323 Fuses of Thyristor with indicators 324 (G) LIGHTING SYSTEM 325 Single Pole MCB 326 Triple pole MCB 327 Fluorescent tube & Starter 328 a) Choke 329 b) Bottom Strips 330 c) Top covers & reflector (if applicable) 331 d) Holders 332 e) Complete fittings 333 Sodium vapour/Mercury vapour Lamps a) Lamp 334 b) Ballast 335 c) Condenser/ Igniter 336 d) Lamp holder 337 e) Lamp holder 338 f) Complete fittings 339 Incandescent lamp 340 a) Bulbs 341 b) Holders 342 c) Complete fittings 343 Switches and sockets 344 Junction box 345 Celing Fan 346 (H) Clamps & Connectors Set 347 (I) Fire Protection System 348 NIFPES System 349 Fitted Nitrogen Cylinder [48 Lit Water Capacity] 350 Hose Pipe with Fittings 351 Heat Sensor Assembly 352 Fire Survival Cable [sufficient for 1 system] 353 PNRV 354 Limit Switches for Fire Detector 355 Fire Detector (for NIFPES System) 356 Thermostat 357 Heating Element 358 (J) Isolators 359 220 kV 360 Solid core Insulator Stacks (Requirement of one Isolator) 361 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 362 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 363 Motor with gear assembly and bevel gear assembly. 364 Bearings (Requirement of one Isolator) 365 Current carrying assembly total (Requirement of one Isolator) 366 132 kV 367 Solid core Insulator Stacks (Requirement of one Isolator) 368 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 369 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 370 Motor with gear assembly and bevel gear assembly. 371 Bearings (Requirement of one Isolator) 372 Current carrying assembly total (Requirement of one Isolator) 373 Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
Contract Date: Jul 18, 2025 Contract Value : 44.55 Crore
Government Departments No of Bidders 3
48.
Defence #7398490 AOC
Tender For Provision Of Otm Accommodation For Fwtf At Afs Yelahanka; 1 BOQ Dated MAR 2025 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Road / Path / Culvert as listed in Schedule ‘A’ Part - IV . 7 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - V . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Rain Water Harvesting” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VIII 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – IX 12 Lumpsum price worked out by the contractor for “Cooling Appliances” as listed in Schedule ‘A’ Part – X 13 Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – XI 14 Lumpsum price worked out by the contractor for “Demolition of Building (B/R & E/M)” as listed in Schedule ‘A’ Part – XII 15 Sch A Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYSupply and fix 15 mm bore two way bib tap and Health faucet cast copper alloy chromium plated fancy type, screwed down, screwed for galvanised iron pipe, complete all as specified and as directed. 16 INTERNAL ELECTRIC SUPPLY S & F modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 17 S & F modular type 6 A 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 18 S & F modular type 16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 19 S & F modular type 2/3 pin combined shuttered type 6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 20 S & F modular type 2/3 pin combined shuttered type 16 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 21 S & F modular type 20 A 1P MCB with socket, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 22 S & F 20 W surface / wall mountedLED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. 23 S & F 10W 2 Feet LED Batten capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 5400K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the engineer-in-charge. 24 S & F 35 W street/Security light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge. 25 S & F 10W Bulkhead LED Lightinput voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed by the engineer-in-charge. 26 S & F modular type 1 module RJ-11 telephone socket with shutter complete all as specified and directed by the engineer in charge 27 S & F modular type 1 module co-axial type TV socket all as specified and directed by the engineer in charge 28 S & F 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed by the engineer-in-charge. 29 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental typeMLTP (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 30 Make: Schneider, Siemens, ABBThe MLTP shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of AL busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i] 320A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]200A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [ii]125A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[iii]63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 5 Nos.[vi] LED phase indicators (Red, Yellow, Blue)- 5 Set 31 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-1 (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 32 Make: Schneider, Siemens, ABBThe panel shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of AL busbar of rated capacity 240A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]200A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]63A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2,front indication LEDs (ready, overload and pre-alarm & overload)- 07 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 07 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 07 Set 33 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-2 panel of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 34 The Panel shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 160 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]125A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING.[i]63A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2,front indication LEDs (ready, overload and pre-alarm & overload)- 07 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 07 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 07 Set 35 EXTERNAL WATER SUPPLYCutting existing DI, 150mm borewater mains and inserting Tee 150mm x 150mm x 50mm for taking branch connection including fittings and joints complete all as specified and directed. 36 Construction of valve chamber with inner clear dimension 600 x 600 x 600mm suitable for 150mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonry 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provision of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embedded in coping with two coats of synthetic enamel paint over a coat of redoxide primer with locking arrangements including necessary earth work complete all as specified and directed. 37 Cutting the existing DI pipe of size 100 mm dia, inserting tee of size 100 x 100 x 32 mm for taking branch connection including necessary jointing materials, joiningtesting etcthreading, including earth work, returning, refilling etc complete all as specified and as directed. 38 Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 7.4 (PN-16) size outer dia 32mm and PP-R plain fittings in trenches/walls/ceilings or laying in floors,including all fittings complete all as specified and directed. 39 Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 7.4 (PN-16) size outer dia 20mm and PP-R plain fittings in trenches/walls/ceilings or laying in floors,including all fittings complete all as specified and directed. 40 EXTERNAL ELECTRIC SUPPLYMaterial and labour for dismantling, shifting and re-installation with complete incomer/outgoing connections, Step down transformer of 11KV/433volts, 200 KVA capacity, from existinglocation including leveling of old foundation complete all as specified and directed by Engr-in-Charge.Note : (i) Rate deemed to be included labour & JCB/crane charges for shifting and connecting up incomer HT and outgoing LTconnections.(ii) Cable jointing kit will be measured and paid separately under relevant items. 41 Supply, install, testing & commissioning of outdoor type step down transformer 11000/433 Volts (at no load), AC, 3 phase, 50 c/s, capacity 500KVA, core type copper wound, oil immersed, naturally cooled, oil natural, air natural, (ONAN) with external cooling tubes/fins delta connected on primary side(HV) and star connected on LT side(LV) in accordance with vector symbol DYN-11(Vector group) with off load type changeover switch with accuracy(+/-)7.5% complete with steps of 2.5% and mounted on existing platform/structure, connecting up with the existing earthing strips,etc.complete.The maximum temperature should not exceed 45° c in oil and 55°c in HV/LV coil winding when measured by resistance method after continuous full run on an ambient temperature of 50°c.The transformer shall be IS 2026 marked and comprise of the following:- 42 (a) cable end box on HV side suitable for 11 KV complete with bushing, copper rods, nuts and washers.(b)One cable box on LV side(secondary side) consisting 03 nos porcelain bushing suitable for 433Volts complete with bushing, copper rods, nuts and washers along with neutral bushings(c)Oil conservator with filter type drain valve and oil level gauge(d)De-hydration breather transparent body with first fill of dehydrating agent(Silica gel)(e)Explosive vent(f)Thermometer pocket on tank cover(g) One no 100mm dia, dial type thermometer,vapour pressure type having range 0° to 120°c with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of neutral and body.(i) Rating plate and terminal marking plate(j) Oil level gauge(k)Oil drain filter valve (l)Lifting lugs(m) Oil filling holes with cap/plug with connecting plate complete(n) Air release valve plug(o)Four plain solid cast steel detachable rollers(p)First filling of new and unused transformer oil IS-335/93(fourth division) marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes complete all as specified and as directed by Engr-in-Charge.Note: Certification of electric strength shall be submitted by the contractor after filling the oil. 43 Returning and filling of trenches in two parts(i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and(ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note :- (i) Excavatedsoil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 44 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all specified and directed by Engr-in-Charge. 45 Supply and fix terminal box made out of SMC with hinged door and locking arrangements of size 200x140x95mm Including Backlite 4 way connector, M S Clamps suitable for pole, PCC/MS/GI/rail etc. with bolt, nut and washer, electrical connections including MCB SP 6-32 Amps complete all as specified and as directed by Engr-in-Charge. 46 M&L for laying 3 core x2.5 sqmm copper conductor, 1100 volt grade, PVC insulated, sheathed for street light fittings from junction box to street light fittings complete all as specified and as directed. 47 Fabricate, supply, install testing and commissioning ofLT panel indoor type made out of ms sheet 2mm thick with locking arrangement and painting, Bus bar AL capacity 600Amps including PCC platform made out of 1:2:4 type B1 and pedestal of 30cm height from ground level with suitable nuts, bolts and washers for mounting of the panel, detachable plate shall be provided at the bottom of thepanel with necessary holes suitable for termination of various sizes of cables with glands and painting with two coats of super enamel paint over the coat of metal primer all as specified and directed and panel shall be suitable to accommodate including supply and fixing of following switchgears (Inside proposed Bldg) :-(a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-1 No(incomer). (b) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-1No. (c) 4 Pole MCCB 63 Amp, 50 Hz, 415V with rupturing capacity 25 KA-03 No. (d) MCB SP 6A , 230 Volts, 50 HZ -1 Nos. (e) Timer switch 250 volts, 20Amps-01 No. (f) Digital Volt meter (0-500 V)-01 No. (g)Digital Ammeter-01 No. (h) CTs 400/5- set of 3Nos. (j) Volt meter selector switch-1 No. (k) Ammeter selector switch- 1 No. (l) LED type Indication lamps (RYB)-01 Set of three. 48 Fabricate, supply ,install testing and commissioning ofLT panel outdoor type made out of ms sheet 3mm thick with locking arrangement and painting, Bus bar AL capacity 1200Amps including PCC platform made out of 1:2:4 type B1 and pedestal of 30cm height from ground level with suitable nuts, bolts and washers for mounting of the panel, detachable plate shall be provided at the bottom of thepanel with necessary holes suitable for termination of various sizes of cables with glands and painting with two coats of super enamel paint over the coat of metal primer all as specified and directed and panel shall be suitable to accommodate including supply and fixing of following switchgears (Inside proposed Bldg) :-(a) 4 Pole ACB 800 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-1 No(incomer). (b) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-2No. (c) Digital Volt meter (0-500 V)-01 No. (g)Digital Ammeter-01 No. (h) CTs 400/5- set of 3Nos. (j) Volt meter selector switch-1 No. (k) Ammeter selector switch- 1 No. (l) LED type Indication lamps (RYB)-01 Set of three. 49 M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to32 x 6mm galvanized MS Strip as earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge. (External Electric Supply - 8 + DG Set - 6) 50 DG SETSupply install testing and commissioning of factory assembled sound proof diesel engine driven generating set, with standard control panel, capable of delivering not less than 320 KVA (256 KW) at NTP conditions including acoustic enclosure as per latest CPCB norms IV+, complete with AMF control panel, common base frame, AVMs, 24 volt starting batteries of suitable rating as per manufacturers recommendation with leads and terminals, charging alternator and control accessories all prewired, residential type silencer and exhaust piping of suitable size (minimum 106 mm dia) duly insulated and aluminium sheet claded and extended upto outside of power house, hand fuel pump with 5.0m long flexible hose, fuel tank of not less than 500 litres capacity & DEF tank not less than 40 litres capacity, fuel line connections, including retrofit emission control device etc with all accessories complete with the following components:-Make of DGset assembled with sound proof canopy - Cummins India / Kirloskar (KOEL Green) / Jackson / Sudhir / Greaves Cotton 51 [a] Engine - 4 stroke multi cylinder, turbo charged, compression ignition, water cooled with standard integral set mounted radiator, continuous rated generator duty engine with CPCB Norms-IV+ approved and having Electronic governing of appropriate class conforming to IS 8528 Part-V, engine capcity capable to generate 320KVA at 0.8 PF at 1500 RPM at NTP with 10% over load capacity for 1 hour once every 12 hours complete with all safety accessories suitable for above DG set, directly coupled with alternator and the engine conforming to BS 5514 / IS10002:1981 complete including first fill of lub oil and coolant all as specified. Make: Cummins / KOEL (Kirloskar) / Greaves Cotton / Cater pillar / Ashok Leyland[b] Alternator:-Self regulated, self exited brushless copper wound alternator, 415 V, 3 phase, 4 wire, 50 HZ, capable to generate200 KVA/160 KW at PF - 0.8 lagging, 1500 RPM, with voltage variation plus or minus 10% of rated voltage from no-load to full-load, foot mounted, screen protected drip proof type with class H insulation, with IP-23 ingress protection, ball/roller bearings at both ends of the alternator shaft, with AVR as recommended by the manufacturer, suitable for direct coupling with engine and conforming to BS-5000/IS-4772 / IEC 60034-1 all as specified. Make: Stamford /Kirloskar (KOEL green) / Crompton Greaves[c]Acoustic Enclosure - Prefabricated factory built, free standing, floor mounting type acoustic enclosure of modular construction suitable for accommodating the 320 KVA Engine Alternator set with integrated fuel tankand should be fabricated with specially formed CRCA sheet metal of thickness not less than 1.60mm for enclosure and 3.0mm for base frame with adequate stiffeners for strength and roof panels designed with slopes to prevent rainwater stagnation and sound proofing with insulation material of PU foam of appropriate thickness and density for sound abruption as per standard design of manufacture to achieve suitable noise attenuation level of less than 75 dBA @ 1 Mtr at 75% load and hinged doors with locking arrangement including emergency stop button at outside. The enclosure shall conform to the latest environment Protection Act 1986 (29 of 1986) of Ministry of Environment and Forest Notification dated 17th May 2002 and 12th July 2004 and as amended up-to-date. Valid CPCB IV+ certificate of authorized agency such as ARAI of Pune, NPL New Delhi, NSTL Vishakhapatnam, FCRI Palghat and NAL Bangalore shall be submitted. 52 [d] AMF Panel - AMF panel with hinged doors with locking arrangement fabricated from 2.0 mm thick CRCA sheet, in dooor type incl all accessories like control wiring and protection devices with 2 Nos 500 A 4 Pole, 36 KA MCCB with Thermal magnetic release, 2 Nos 500 Amps AC 3 duty 4 pole power contactors for mains supply and DG supply with inter connecting aluminium bus bars, electronic earth fault protection relay, micro processor based AMF controller having facility to start the DG set and restore power supply within 15 seconds of power failure with communication port, frequency meter, 3 Phase electronic type AC KWH meter with suitable 3 Nos CTs 500/5A, electronic earth fault protection relay, AC volt and Ampere meter, HRC fuses, push buttons for start / stop / reset, LED type indicating lamps as required, SMPS based battery charger with automatic float & boost changeover facility, control circuit fuses/MCBs, reverse power relay, alarm for high water/ lub oil temp and low lub oil pressure and any other control devices/measuring instruments as recommended/required in accordance with latest engineering practices andspecifications as recommended by OEM and asdirected by Engr in Charge.AMF Controller Make :-As per OEM) 53 COOLING APPLIANCESSupply, fixing, jointing and testing copper tubing with nominal diameter1/4 inch of suitable thickness for liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 54 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of suitable thickness including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 55 Material and Labour for fabrication of base stand from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC complete all as specified and directed by Engr-in-Charge. 56 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 57 LIGHTNING PROTECTIONMaterial and labour for corrosion resistant earthing system completecomprising ofthe following items:-(a) 17.2 mm dia, 3mtr length,Low carbon steel earth electrodewith minimum 250 micron copper bonding certified by CPRI. (Copy of CPRI certificate to be submitted.(Dia of the rod &control number allotted to the manufacturer should be embossed on the rod and certificate from the same manufacturer shall be submitted along with the material). (b) 25 kgs of earth enhancement material, environment friendlybackfill compound. (c) Suitable clamp, 17.2minimum outer dia SS clamp both side. (d) Rust & weather proof heavy duty FRP earth pit chamber with dimensions 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). (e) Exothermic welded joints. (f) Provision of one copper bus bar near tapping point for connection complete all as specified and directed by Engr-in-Charge. Make:CAPE/JEF/ABB Fuse. 58 SPECIAL ITEMS OF WORKSupply and fix LED spot lights (focus light), 10 Watt, warm white colour, 180 degree adjustable wall/ceiling mountable, white body complete all specified and directed by Engr-in-Charge. 59 Supply and fix 32mm dia PVC conduit complete all specified and directed by Engr-in-Charge. 60 Supply and fix industrial grade socket single pole and neutral enclosure with a two pin and earth plug socket including one SPN MCB of 16 Amps, C Curve, 10 KA rupturing capacity complete all specified and directed by Engr-in-Charge. 61 Supply and fix SPD 320 Volts, AC complete all specified and directed by Engr-in-Charge. 62 Supply and fix Electric Chimney of size 90 CM, Air suction capacity 1420 Nm3/Hr, Filterless and automatic clean technology, Air pipe of size 160 mm dia complete all specified and directed by Engr-in-Charge. 63 DEMOLITION OF BUILDING (B/R & E/M)Dismantling and taking down old PVC Sintex Tank of capacity 10000 Ltrs complete all as specified and as directed. 64 Dismantling and taking down ofold unserviceable MCB DB 8 way including MCBs of any type/size complete all as specified and as directec. 65 Taking down old unserviceable service wire 2 core 10 Sqmm complete all as specified and as directed.
Contract Date: May 27, 2025 Contract Value : 7.68 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
49.
Educational and Research Institute #7183083 AOC
E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Depart. Of Maynaguri Govt. Poly E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Dprt. Of Maynaguri Govt. Poly. , Aggregate Crushing Value Test Apparatus As Per Is:2386 (Part 4) 1963 , Auger Extra Extension Rod, 1 Meter Long With Screw Type Fitting 6 To 12 Ms Auger To Drilling Into Soil Upto 3 M Manually. Mostly Used For Normal Soil And Earthing Pit Purpose. , Blaine Air Permeability Test Apparatus For Measuring Fineness Of Cement As Per Is 5516. Air Permneability Apparatus (Blaine Type) With Isi Certification Mark Is;S516, Fitted In Aluminium Box With Permeability Cell. U Tube Manometer, Mounted On Stand. Perforated Metal Disc. Plunger. Rubber Stopper. Rubber Tube, 20 Cm Long. Filter Paper Discs (Twelve Nos.). Dibutylphthalate Liquid, 100 Ml Bottle. Punch. Non Perforated Disc. Suction Bulb And All Other Accessories Required As Per Is Code. It Should Be Supplied With Standard Cement Required For Calibration(Calibration To Be Done By The Supplier In Presence Of Concerned Authority) And Mercury Of Requisite Quantity, Crucible. , Bod Incubator Chamber Made Of Aluminium 375 Mm X 375 Mm X 450 Mm With 10 Numbers 300 Ml Bod Bottle. Specifications: Temperature Range 5 To 60°C, Temperature Accuracy + / - 0.5°C, Temperature Uniformity + / - 0.5°C, Power 220 Volt, Temperature Control Microprocessor Control, Cabinet M.S. Steel Powder Coated Inner Chamber Stainless Steel, Shelves 3 Stainless Steel, Etc. , Buoyancy Balance Buoyancy Balance Helps In Determining The Specific Gravity And For The Water Absorption Of The Aggregate. It Is Fitted With The 15 Kg Capacity X 0.5 Gm Of The Electronic Balance. Buoyancy Balance Comprising Of An Electronic Balance Of 15 Kg Capacity, Chain & Ratchet Assembly In A Steel Tubular Frame. , Cbr Value Apparatus As Per Is 2720 (Part-16)-1987 Laboratory California Bearing Ratio Test Apparatus, Motorised Laboratory Cbr Apparatus Meets The Essential Requirements Of Is: 2720(Part Xvi) With The Mould As Per Of Is: 9669. , Cod Digester Along With Vials,Holding Rack, 16 Sets Of Glassware (Cod Digestion Tubes With Screw Caps And Cod Air Condensers) Holds 16 Nos. Of 16 Mm X100 Mm Dia Tube. Temperature Range 0- 200 Degree Celcious, Temperature Can Be Set Within This Range. Time Range 0 To 120 Minutes, Stability Plus Minus 0.5 Degree Centigrade, Over Temperature Cut Off. When Digestion Complete, Reactor Automatically Turns Off And Will Sound An Alarm. 230 Volt. 16 Mm X 100 Mm Culture Tubes With Tfe-Lined Screw Caps ( 16 Nos.) Holding Racks Of Stainless Steel. , Compacting Factor Test Apparatus Compaction Factor Apparatus As Per Is: 5515-1983 With Nabl/Nccbm Certificate. , Constant & Falling Headpermeability Apparatus With Water Reservoir As Per Is 2720 (Part 17)-1986. Laboratory Permeability Apparatus: Is: 2720 (Part-17), Is 11209 Suitable For Both Constant Head As Well As Falling Head Permeability Tests. Stand With Three Glass Tubes Of 6 Mm, 10 Mm And 20 Mm Dia Approx. Metallic Mould 100 Mm Dia X 127.3 Mm Height, 1000 Ml Volume. Extension Collar 100 Mm Dia X 60 Mm Height. Drainage Base Plate With A Recess For Porous Stone And An Outlet Valve. Metallic Clamping Ring Drainage Cap With Recess For A Porous Stone And Fitted With Inlet Valve And Air Release Valve. Dummy Plate To Serve As False Bottom During Compaction. Porous Stone For Drainage Base Plate. Porous Stone For Drainage Cap Rubber Connection Tube 3M Long, With Pinch Cock. Overhead Tank, Required For The Constant Head Method Made Of Steel, Approx. 37.5 Cm Dia And 1M High. It Is Provided With An Inlet Port At The Top, Six Outlets At The Bottom With Cocks, Air Inlet And Water Filling Tube At The Top. An Arrangement To Indicate The Water Level Is Also Provided With Rammer 2.6Kgx310 Mm Controll Fall And 4.9Kgx450mm Controll Fall. , Cube Mould, Size: 150 Mm X 150 Mmx 150 Mm (Made Of Cast Iron With Isi Certification) , Cube Mould, Size: 70.6 Mm X 70.6 Mmx 70.6 Mm (Made Of Steel With Isi Certification) , Cylindrical Core Cutter With Steel Dolley, Steel Rammer And Other Accessories. Apparatus Should Consists Of: 1. Cylindrical Core Cutter Of Steel Material Of About 130 Mm Long And 100 Mm In Diameter. 2. Steel Rammer Of About 140Mm.Dia., 75Mm Height And 900Mm (Total Height Including Handle.).Weight Of Rammer Should Be Of 9 To 10 Kg. 3. Steel Dolly 25 Mm High And 100 Mm In Diameter. 4. Palette(Steel) Knife 5. Steel Ruler. 6.Metal Straight Edge. 7. Spade Or Pickaxe.. 8 Apparatus To Extract Core Sample. 9.Moisture Cans(Six Nos. Of Aluminium Material). , Cylindrical Metal Measure (3, 15 And 30 L Capacity) For Determination Of Specific Gravity Of Coarse Aggregates As Peris 2386 (Part Iii) : 1963 , Density Basket Conforming To Is: 2386(Part-Iii)-1963 For Determination Of Specific Gravity & Water Absorption. It Is Made Of G.I. Wire-Mesh Of Approximate Size 20 Cm Dia X 20 Cm High. Complete With Handle. , Desiccator( 250Mm Dia , Material Pp/Pc) , Digital Flocculator With Six Jar (Standard Jar Tester) Designed For Floc Formation Test In Water Treatment Plant. Uniform Stirring Of Up To 6 Samples Simultaneously. Variable Speed Of 20-100 Rpm. Heavy Duty 1/20Hp Motor With Gear Train Mounted On A Mild Steel Housing. Supported By Six Rods On A Bench. Stainless Steel Stirring Paddlers With Adjustable Height. Locking Collars Or Stirring Rods Permit Adjustment Height Of Paddle Height. Spacing Of 6” (150Mm) Between Rod Permit Uses Up To 1000Ml Beaker. Housing Material: Crc / Ms Sheet Duly Powder Coated. Power Consumption: 220/230V Ac Supply 50Hz Single Phase. Motor: 1/ 20Hp Motor Good Quality. Compulsory: Digital Rpm Meter/Timer/Dc-Drive For Low Rpm Illumination: By Tube Lights (With Choke + Stirrer) Duly Covered By Perspex Sheet Having Control Switch Fitted On The Control Panel. , Digital Planimeter Digital Planimeter- (Specification: Roller Type, Accuracy-(+-) 0.2%(Within (+-) 2/1000 Pulses), Accumulated Measuring Value Maximum 10 Sq.M (Scale 1:1), Measuring Range-A) Maximum Vertical Width 325 Mm,B) Horizontal Roller Rotatant Length-30M, Display Liquid Crystal, 8 Digit Figures. Higher Specification Will Be Preferred.) , Digital Rebound Hammer With Calibration Anvil (For Concrete Compressive Strength Analysis In The Field) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881 202 And Other International Standards. Range:10 To 70N/Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Relbound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Softvware And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided. , Direct Shear Test Apparatus As Per Is 2720 (Part13)-1986 12 Speeds, Motorised Is: 2720 (Part Xiii) Is: 11229 Supplied Complete With Proving Ring And 2Nos. Of Dial Gauge Of 0.01X 25Mm. 2Kn With Dial Gauge 2 Nos.& Compression Tension Proving Ring 2Kn; Type Of Shear : Direct / Residual Measurement, Operation : Motorised The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Suitable For Operation With 220V, 50 Hz, Single-Phase Supply. It Comprises: - I) Shear Box Assembly (Halves Of The Shear Box 2 Nos),60 Mm Square, Complete With A U-Bracket, Guide Pins And Spacing Screws, Made Of Brass. Ii) Gripper Assembly Consisting Of Two Plain Grid Plates, Two Perforated Grid Plates, One Base Plate And One Loading Pad, All Made Of Brass. Iii) Two Porous Stones, Each 6 Mm Thick, Fitting The Shear Box Iv) Shear Box Housing Of Brass, Complete With Two Ball Roller Strips. V) Loading Unit With Normal Loading Of 3 Kg/ Cm2 On 60 Mm Square Specimen. Vi) Specimen Cutter For A Specimen Size Of 60 Mm X 60 Mm X 25 Mm. Vii) The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Surcharge Weights To Attain Normal Stress Of 3 Kg/Cm2 1 Set, Surcharge Weight Set Comprises Of Following Weights : 0.05 Kg/Cm2: 4 Nos.; 0.10 Kg/ Cm2: 1 No.; 0.20 Kg/ Cm2: 1 No.; 0.50 Kg/ Cm2: 3 Nos.; 1.00 Kg/ Cm2: 1 No. 1. Conforming To Is 2720 (Part – 13) Of Latest Edition , Ductility Testing Apparatus As Per Is: 1208 -1978 Ductility Testing Machine (Is: 1208 -1978) For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould (Total Length 75 0.5 Mm, Distance Between Clips 30 0.3 Mm, Width At Mount Of Slip 20 0.2 Mm, Width At Minimum Cross Section 10 +0.1 Mm, Thickness Throughout 10 + 0.1 Mm) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm/Mnt And S Cm/Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. , Electronic Balance, Capacity 2 Kg. Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 2 Kg And Sensitivity As 0.01 G. , Electronic Digital Balance(20Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 20 Kg And Sensitivity As 1 G. , Electronic Digital Balance(25Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 25 Kg And Sensitivity As 1 G. , Pipe Friction Apparatus The Apparatus Is To Be Used To Measure Darcy’S Friction Coefficient (F) For Fluid Flow Through A Given Pipe. The Apparatus Should Consist Of: • A Centrifugal Pump Of 25Mm X 25Mm With 1/2 Hp Mono-Block Pump (Kirlosker Or Equivalent Make), • Sump Tank (80 Cm X 35Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) To Collect The Water, • Measuring Tank ( 45Cm X 30Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) Fitted With Piezometer Tube To Measure The Discharge, • G.I. Pipe Of Internal Diameter 25.4Mm (1) And Isi Marked Control Valve And Regulating Valves To Be Provided To Circulate Water, • Bye-Pass Line Is Also To Be Provided Along With Regulating Valve To Regulate The Discharge, The Apparatus Should Consist Of Three G.I. Pipes Of Internal Diameter ½”, 3/4 & 1” Respectively. The Pressure Tapings Are Provided 100Cm Apart On Each Pipe. Each Tapings Are Connected To The Mercury U Tube Manometer To Measure Head Difference. Hand Shuts Valves Are To Be Provided At Each Pipe Inlet And Outlet To Control The Supply In The Pipe. The Tanks And All Other Ms Fittings Should Be Well Epoxy Painted (Both Inside & Outside) To Prevent Rust. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Apparatus And Installation And Demonstration Are To Be Given. , Flash And Fire Point Apparatus Pensky Martens Flash Point (Closed) Tester (Electrically Operated) With Npl Certificate Is: 1448 (Part 21) 1209, Ip 34/58, For Determining Flash Point Of Petroleum Products (Above 490C Flash Point Range). It Has A Brass Coil Cup Fitted With A Heat Resistance Handle. The Cup Is Provided With A Lid Which Includes Stirring Device, A Cover, Shutter And A Flame Explosive Device. The Shutter Is Operated By A Spring Handle. A Flexible Shaft Is Provided In The Hand Operated Stirrer. A Cast Iron Stove Is Fitted With A Metal Top Plate Mounted On An Upright Member (Gas Manifold) And It Feeds A Needle Valve-Controlled Burner Supplied With A Hot Plate. The Energy Regulatory Controls The Heating. Suitable For Operation On 220 V, 50 Hz, Single Phase Ac Supply. Flash Point (Open) And Fire Point Cleveland With Npl Certificate Electrical Heating Thermometer Range: -6°C To +110°C (Low Range), 90°C - 370°C(High Range) Ref. Standards - Is:1448 (Part 69), For Determining The Flash And Fire Points Of Petroleum Products, Except For Fuel Oil And Those Products Which Have Open Cup Flash Point Below 79° C (175° F). Consisting Of Cleveland Flash Cup Brass (Dia. 63 - 64 Mm, Height 32.5 - 34 Mm, With A Filling Mark Is Engraved At A Distance Of 9 To10 Mm Below The Surface Along With An Insulated Handle. Gas Test- Jet Assembly Correctly Positioned And Pivoted From A Cast Cup Platform Which Is Fixed To A Heating Bath. Energy Regulator, To Regulate The Rate Of Rise In Temperature 220 V, 50 Hz, Single Phase, Ac Supply. With Thermometer Ip28c Range: -6°C To +110°C. , Heating Mantle For Bitumen Test As Per Is And Branded , Hot Air Oven Electrically Operated With Digital Indicator Cum Controller With Safety Alarm, Range 50°C To 250°±1°C With Air Circulating Fan, S.S, Inside Size 600 Mm X900 Mm X450 Mm , I.S. Sieves[For Aggregate (Coarse And Fine Aggregates & Soil] 1. Sieve G.I. Frame Material Of Construction: G.I; Protective Coating : Powder Coating; Weight: Preferably 800Gm- 900Gm; Wire Mesh Preferably Imported Quality Size: 100Mm, 80 Mm, 63Mm, 50Mm, 40Mm, 31.5 Mm, 25 Mm, 20Mm, 16 Mm, 12.5Mm, 10Mm, 6.3Mm, 4.75Mm, [Bis:460 Part I & Ii 1985, Reaffirmed 2008] ; Pan And Cover For 30Cm Dia Sieves Material Of Construction: G.I; Protective Coating : Powder Coating Upto 6.3 Mm And The Rest Are Made Of Brass (As Mentioned Earlier) Weight: Preferably 800Gm- 900Gm; 2. Sieve Brass Frame 20Cm Dia Material Of Construction: Brass Type: Seamless Weight: Preferably 250Gm- 350 Gm Wire Mesh Preferably Imported Quality Size: 4.75Mm, 2.36 Mm, 2 Mm, 1.18 Mm, 600 Micron, 425 Micron, 300 Micron, 150 Micron, 90 Micron 75 Micron [Bis:460 Part I & Ii 1985, Reaffirmed 2008] Pan And Cover For 20Cm Dia Sieves With Lid And Pan Conforming To Is:460 Part I 1978; With Brushes For Cleaning Sieve. , Length Gauge Conforms To Is:2386 (Part-I) , Los Angels Abrasion Testing Machine With All Accessories Los Angeles Abrasion Testing Machine With Counter (As Per Is: 10070-1982) , Mechanical Liquid Limit Device With Grooving Tool (Casagrande And Astm), Porcelain Evaporating Dish , Spatula, Palette Knives As Pe Is : 9259-1979. , Piezometer Tube It Consists Of Glass Tube Connected To A Vessel At Which Static Pressure Is To Be Measured. It Is The Simplest Of All The Manometers. It Is Used To Measure Very Low Pressures. The Shape And Size Should As Per Indian Standard. The Glass Material Should Be Of Good Quality, Virtually Unbreakable And Should Not Show Any Type Of Distortion During Experiment. The Cost Of The Item Should Include Supplying, Installation, And Demonstration. , Plane Table Set 1.Plane Table – It Should Be Well Seasoned, Good Quality Drawing Board Made Of Pine/Teak Wood Having Smooth, Plane Finish On Its Top And Fitted With Ball And Socket Arrangement Of Size 60Cmx50cmx1.5Cm Or 75Cmx50cmx1.5Cm. 2. Plane Alidade – Plane Alidade Should Be Of Metallic (Brass Or Gun Metal) With A Fine Beveled Edge. 3.Spirit Level:- Tubular Level, Which Can Be Placed In To Perpendicular Position. 4. Trough Compass:- Usually 15Cm Long And Provided With Magnetic Needle To Facilitate Orientation Of The Plane Table And To Mark North Direction. 5. U-Frame Plumbing Fork:- Hairpin-Shaped Brass Frame Having Two Arms Of Equal Length One End Of Frame Is Pointed, The End Of The Frame Carries A Plumb Bob. 6. Clamps :- Minimum Four Nos. Of Suitable Size. 7. Tripod Stand:- Should Be Of Standard Size Of Either Aluminium Or Good Quality Wooden Material. 8. Plumb Bob:- Standard Size ,Brass Metal. , Plastic Limit Apparatus Conforming To Is: 2720 (Part V) , Proctor Test Apparatus [Light And Heavy Compaction] Proctor Compaction Test (Modified And Standard) Bis: 2720-Part 7 1974. , Pycnometer For Determination Of Specific Gravity Of Sand And Fine Gravel. Consisting Of A Glass Jar Of 1 Kg Capacity, Complete With Brass Cone, Rubber Seal And Screwed Cap As Per Standard Is: 2386 (Part Iii). , Ring And Ball Apparatus Conform To Is:1205 (Electrically Operated) Ring And Ball Apparatusas Per Is: 1205, , Sand Replacement Apparatus [Large] As Per Is:2720 (Part Xxviii). , Sand Replacement Apparatus [Small] As Per Is:2720 (Part Xxviii). , Survey Umbrella , Shrinkage Limit Apparatus (Supplied With Requisite Quantity Of Mercury) The Apparatus Conforms To Is: 10077, And The Test Is Performed As Per Is: 2720 (Part Vi). The Set Consists Of: I) 75 Mm Square Prong Plate Made Of 3 Mm Thick Acrylic Sheet With Three Metal Prongs. Ii) Stainless Steel Shrinkage Dish 45 Mm In Dia, 15 Mm Deep. , Sieve Shaker, Motorised Having As Tardy Cast Iron Body, The Shaker Has An Inclined Sieve Table Which Can Accommodate A Max Of Seven Sieves Of 200 Mm Dia. An Adjustable Top Clamping Plate Is Provided To Hold The Sieves. The Table Has A Gyratory Motion In Addition To Up And Down Jolting Action. The Operating Gear Assembly Is Enclosed In An Oil Bath Fitted With Transparent Oil Level Indicating Window. Suitable For Operating On 220V, 50Hz, Single Phase Supply. Time Switch Adjustable From 0-60 Minutes; Lid And Receiver For 200 Mm Dia Sieves, Made Of Brass; Adopter For 300 Mm Dia Sieves; , Slump Test Apparatus With Tamping Rod And Base Plate Slump Test Apparatus As Per Is: 7320-1974. , Thickness Gauge As Per Is 2386 (Part I) : 1963 , Total Station Total Station.Telescope: Magnitication : 30X Or Better; Image : Erect; Angular MAsurement: Angular Accuracy : 5 Or Better: Least Count: 1 Or Better; Distance Measurement: Distance Range With Single Prism : 2.2 Kms Or Better (Under Normal Conditions) Distance Without Prism : 270 M Or More Laser Output In Prism Mode Class1 (Safe For Human Eye)Distance Accuracy In Prism Mode: 2Mm 2Ppmxd Or Better General:Display : Dual Face Alpha Numeric Keyboard (Identical Display)Compensator : Type: Dual Axis / Range: 3 Or More. Battery Rechargeable Battery (Operational Time Approx.12 Hrs Or More For Each Battery |2 Nos Battery To Be Supplied| Quick Charger. : Ino.Dust & Water Proof Protection : Ipss Or Better.Optical Plummet : 3X Or Better/Llaser Plummet Weight With Handle & Battery :5 Kgs Or More.Memory Management System With Multiple Data Interfaces As:Internal Memory : Approx 10,000 Points Or More. Plug In Memory Device : Usb Flash Memory. Accessories:Aluminium Telescopic Tripod. : Inosingle Prism Assembly Consisting Of: Inorange Pole, Prism, Target Plate, Spirit Bubble, Tripod All In Carrying Cases.Data Communication Sottware : Lnothe Minimum Tolloving Application Software Should Be Loaded In The Instrument.Topography, Resection, (Setting Out Of Co-Ordinates, Line, Arcs), Area Calculation, Etc. Catalogue Of The Quoted Model To Be Enclosed With The Bid (Without Which Bid Should Not Be Considered For Technical Evaluation, Physical Training To The Respective Institute After Successful Supply, Ater Sales Service Is Also Mandatory As When Required, , Turbidity Meter With Standard Solution Specification For Bench Top Turbidity Meter With Digital Display: Supply, Installation, Commissioning, Functional /Performance Testing, Demonstration, Training And Warrantee From Oem Or Their Authorized Dealer For Bench Top Turbidity Meter With Digital Large Full Colour Touch Screen Display Unit & Easy Data Export System Having Minimum Following Specification And Including Specified Numbers Of Standard Accessories. The Instrument Should Be Operable On 220 V Ac, 50 Hz. Specifications Range Turbidity Range (Ntu): 0 To 4000 Ntu (Nephelometric Turbidity Unit) Range Selection: Automatic Resolution: 0.001 Ntu, Accuracy: ± 2% Of Reading Plus 0.01 Ntu From 0 - 1000 Ntu, ±5% Of Reading From 1000 - 4000 Ntu Or Better Repeatability: ±1% Of Reading Or 0.01 Ntu Whichever Is Greater Light Source: Tungsten Filament Lamp Standard : Designed To Meet Epa 180.1 Response Time: < 15 Seconds Operation And Service Manual Should Be Included With The Main Instrument At The Time Of Supply. Instrument Should Have All The Standard Accessories Like Silicone Oil, Oiling Cloth, Filter Assembly, Sample Cells With Caps , Turbidity Standardization Solution Kit, Calibration Kit, Dust Cover At The Time Of Supply. Instrument Should Be Latest Model And It Should Not Be The Obsolete Model. , Universal Testing Machine (100T) Analogue, Universal Testing Machine As Per Is, Capacity 100T. , Vicat Apparatus Vicat Apparatus With Isi Certification Mark Is:5513 Fitted In Aluminium Box (Is-1727, 2541 (P.2), 2645, 4031) The Mould Is In The Form Of Frustum Of A Cone Having Internal Diameter At Lower And Upper End 70 And 60 Mm Respectively And A Height Of 40 ± 0.2 Mm. Needle For Initial Setting Time Determination: The Needle Is Circular/Rectangular In Cross-Section Having A Cross Sectional Area Of 1Mm².With Flat End.- 3Set Needle For Final Setting Time Determination: Having A Cross Sectional Area Of 1Mm² With Flat One End And A Collar At The Other End Having Dia Of 5 Mm And Needle Projects Beyond The Collar By 0.5 Mm – 3Set Polished Brass Plunger With A Projection At The Upper End For Insertion Into The Movable Rod With Flat Lower End Dia 10 Mm, 50 Mm Long- 3Set Sample Capacity : 400 Gms.( Ordinary Portland, Rapid Hardening Portland, Low Heat Portland)Front Scale Should Be Made With Brass (Can Be Measured From Top And Bottom ) Provided With Standard Bottom Glass Plate For Mould As Per Is Code , Bernoulli’S Apparatus The Self-Contained Experimental Set-Up Is To Be Provided With Water Recirculating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. An Arrangement Is To Be Provided To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Test Section: Material Acrylic, • Piezometer Tubes: Material P.U. Tubes (7 Nos), • Water Circulation: 0.5. H.P. Pump, • Flow Measurement: Using Measuring Tank With Piezometer, Capacity 25Lts. • Sump Tank: Capacity 70 Lts., • Intel Tank: Capacity 20 Lts., • Stop Watch: Electronics, • Control Panel Comprises Of Standard Make On/Off Switch, Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. • The Inside Surface Of The Tank And All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Combined Venturimeter And Orificemeter Apparatus The Apparatus Should Consist Of 2 Pipe Line Emerging Out From A Common Manifold. One Pipeline Contains A Venturimeter, Second Contains An Orifice Meter. The Pressure Taping From The Venturimeter And Orifice-Meter Are Taken To Differential Manometer To Measure Pressure Difference. The Venturimeter And Orificemeter Are Connected In Parallel And Any One Of Them Can Be Put In Operation By Operating Valves Provided At The Upstream And Downstream. The Flow Can Also Be Regulated By Theses Valves. The Set-Up Is To Be A Self-Contained Water Re-Circulating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. Flow Control Valve And By-Pass Valve Are Fitted In Water Line To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Venturimeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Orificemeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Water Circulation: 0.5. H.P. Pump (Standard Make). • Flow Measurement: Using Measuring Tank, Capacity 40 Ltrs. • Sump Tank: Capacity 60 Ltrs. • Stop Watch: Electronics. • Control Panel Comprises Of: Standard Make On/Off Switch Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. The Inside Surfaces Of The Tank All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Water Distillation Apparatus The Still Is An Essential Part Of Equipment In Modern Material Testing Laboratories. In Operation The Water Is Heated Gently And Converted To Steam By Keeping It Boiling At A Slow Rate. The Steam Is Condensed In An In-Built Condenser And The Distillate Collected In A Receiver. This Is Free From All Impurities And Gases. Cooling Water Consumption 60 Liter/Hr Biological Activity Pyrogen Free Ph 6 -7 Conductivity S/Cm <3 × 10-6 Distillate Temperature 65 - 75?C Copper, Brass, Bronze And Tin Are Used In The Fabrication Of The Stills. The Surfaces Coming In Contact With Water Are Heavily Tinned Which Prevents Metallic Contamination. A Water Inlet Valve Is A Part Of The Still For Connecting To A Tap. An Overflow Is Also Provided To Maintain The Water At Proper Level. The Still Has4 Litre/Hour Distillation Capacity, Suitable For Operation On 220 V, 50 Hz, Single Phase Supply. , Kvl , Kcl Trainer Kit With Adequate Voltmeter Ammeter And Multi Meter , Rlc Resonance Trainer Kit , Analog Micro-Ammeter(0-1000?A) (Ac) , Analog Milli-Ampere(0-1000Ma) (Ac) , Digital & Analog Bread Board Trainer , 8085 Trainer Kit 16 X 4 Line Lcd Display & 101 Pc Key Board. With Power Supply & Rs232c Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8255 Study Cum Logic Control Card , 8 Bit Adc & Dac , 8051 Trainer Kit 16X4 Line Lcd Display & 101 Pc Key Board With Power Supply & Rs 232X Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8051 Development Board , Stepper Motor & 12V Dc Motor Control With Motor Mounted & Direction Control , 8 Bit Adc & Dac , Lcd Interface Module , Relay Interface Module , Digital Ttl Logic Gate Trainer Kit , Digital Cmos Logic Gate Trainer Kit , Adder/Subtractor Trainer Kit , 4 Bit Multiplexer & De-Multiplexer Trainer Kit , Flip Flop Trainer Kit , 4Bit Shift Register Trainer Kit , Decade Counter Decoder Driver & 7 Segment Display (With 1 Hz Squarer Generator) Trainer Kit , Programmable Counter Using 7490 Ic Trainer Kit , Digital To Analog And Analog To Digital Converter Trainer Kit , Bcd To 7 Segment Decoder Trainer , Ic 555 Trainer Kit , Linear Potentiometer (With Scaling) , Rotary Potentiometer (With Scaling) , C Type Bourdon Tube Pressure Gauge (Spec: 0- 100Psi, Accuracy 1%) , Dead Weight Tester With Bourdon Tube Pressure Gauge , Dead Weight Tester With Bourdon Tube Pressure Switch , Strain Gauge Load Cell , Lvdt Trainer Kit , Hall Sensor Trainer Kit , Piezoelectric Transducer Trainer Kit , Stroboscope , Rtd , Thermocouple , Thermistor , Pyrometer , Manual Installation Of Flow Line Along With The Different Flow Measuring Instruments (Orifice, Venturi, Rotameter, Magnetic Flow Meter, D/P Transmitter) , Conductivity Gage For Level Measurement , Capacitive Gagefor Level Measurement , Gauge Glassfor Level Measurement , Float Typefor Level Measurement , Displacer Typefor Level Measurement , Control Valve , Temperature Control Loop With Using On Off Controller With Temperature Sensor , Complete Set Up Of Process Control Unit For Level & Flow Using Analog Dp Transmitter & Computer Interface With Pid Control Full Set Without Pc. , Complete Set Up For Single Loop Flow Control Unit Using Mass Flow Meter With Control Valve. , Pid Controller Master Unit Containing Analog Pid As Well As Pc Based Pid With Computer Interface Adaptor & Self Extracting Pid S/W On Cd With Process Simulator Panel. , Pcb Stencil Printer , Dc Shunt Motor: ½ Hp, 220V,1500 Rpm (Gee Make)Dc Starter : ½ Hp , 220V, 3-Point Starter, Panel Mount Type, Ammeter : 2A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Voltmeter: 300V, Mc Type,Panel Mount, 96 Sq. Mm (Ae Make), Ammeter: 1A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Rpm Meter: Digital, Panel Mount With Proximity Sensor (Select Make), Rheostat :( 0-50O, 5A, And 0-500O, 1.5A) Screw Motion Type, Cont. Variable, Potential Divider: 500O, 2A Screw Motion Type, Cont. Variac-1No. Motor Are Fitted On Ms Channel Base. All Meters, Starter- Are Mount On Self Stand Bakelite Panel Board. All The Terminals Of The Motors, Meters, Starter, Mcb Etc. Brought Out On The Panel For Flexible Connection With Connecting Patch Cords. , Transformer : 1 Kva, 230V / 115V, 50 Hz Variac : Single Phase, 10A, Input : 230V, Output : 0-270V, 5A, Voltmeter: 300V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 150V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 50V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Ammeter : 0-5A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 0-10A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make) : 0-1A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Wattmeter: 300V / 5A, Digital, Pf : 0.2 To 1.0, Class : 1, 96 Mm X 45 Mm (Schneider).All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board.All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Variable Dc Source : 0-24V, 0-500Ma, Continuous Variable Dc Source Dc Voltmeter: 0-50V, Mc Type, Class : 1.0, 96 Sq. Mm. Ammeter :0-1A, Mc Type, Class : 1.0 96 Sq. Mm. Load : 0-500Ma, 24V Resistive Load, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Kelvin Double Bridge:Range Of Measurement: 0.1? – 0.92?, One Digital Galvanometer Provided To Indicate The Balance Conditions. Required Patch Chords Are Provided. Input Voltage :15V Dc Output Voltage :5V Ac, Output Current :1 Amps, Kelvin’S Double Bridge, Patch Cards, 1A Power Supply Adaptor, Manual , Insulation Tester (Hand Driven Generator Type), Rated Resistance: 0-2000 Mohm, Rated Voltage: 500 Volts, Scale Length: 90Mm (Approx.), Rotation Speed: 160 Or More R.P.M , Fluorescent Lamp Set Up With Copper Ballast, Starter, Capacitor Etc. (Philips) Variac : Input :230V Ac, Output : 0-250V, 2A, Panel Mount Type (Penta), Wattmeter : Digital Panel Type, 0-300V / 0-2A (Schneider Make), Voltmeter : Digital Panel Type. 0-300V Ac (Select Make) – 3 Nos. Ammeter: Digital Panel Type. 0-2A Ac (Select Make),All Mount On A Self Stand Bakelite Panel Board. All The Terminals Of Each Inst. Brought Out On The Panel.Connecting Patch Cords, Dp Mcb, Indicator. , Wien Bridge: Supply:- ±12V D.C. At 100Ma, Ic Regulated Power Supply Internally Connected1khz Sine Wave Oscillator Audio Amplifier And Speaker For Null Detection Three Decade Resistances, Single Dial In Steps Of 100 Ohm, Total 1K Each,Two Dials Of 10 Ohm & 100 Ohm, Total 1100 Ohms To Form Arms Of Bridge Decade Standard Capacitance, Selectable By A Band Switch To Form The One Arm Of The Bridge Unknown Capacitor And Adequate No. Of Other Electronic Components Mains On/Off Switch, Fuse And Jewel Light The Unit Is Operative On 230V ±10% At 50Hz A.C. Mains Adequate No. Of Patch Cords Stackable From Rear Both Ends 4Mm Spring Loaded Plug Length ½ Metre Good Quality, Reliable Terminal/Sockets At Appropriate Places On Panel For Connections/Observation Of Waveforms , Maxwells Inductance Bridge: Four Arms Are Provided With Suitable Connectors, 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge, Measurement Range 15Mh – 200Mh, Connector Facility Given To View The Output Of The Bridge Externally By Cro, Patch Chords, Input Voltage 15V Dc, Output Frequency 1Khz, Output Voltage 2V Ac, Output Current 0.5 Amps, Patch Cords, 1A Power Supply Adaptor. , Schering Bridge: Built In Dc Power Supplies Fixed. Operated On Mains Power 230V, 50Hz +10%, Sine Wave Generator: 0-1Khz Sine Wave Oscillator, Null Detector: Speaker, Componentsmounted On The Panels : Arm, R1 Four Decades Of Resistance 1 Ohm To 10K Ohm Through Rotary Switch. Arm, R2 Six Different Values Of Resistance Through Rotary Switch. Arm, Cx Three Different Values Of Unknown Capacitance Through Rotary Switch.One Arm Asfixed Capacitor. , Scr- Trainer Kit: Variable Dc Source: 0 ~ ±250V, 0.75A, Variable Dc Source: 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Simple Screw Jack Appratus , Worm And Worm Wheel Appratus , Double Purchase Crab Winch Appratus , Horizontal And Inclined Plane Friction Slide Apparatus , Haematite Ore (1 Kg) , Copper Pyrites (1 Kg) , Powdered Coal Sample (1 Kg) , Tlc Uv Cabinet , Hot Plate With Magnetic Stirrer , Magnetic Stirrer , Digital Muffle Furnace (220-230V, 900°C) , Sample Cells (Round Glass, 10 Ml) , Sample Cells (Square Glass, 10 Ml) , Chloroscope , Air Compressor , Digestion Vessels (12 Pieces Box) , Block Heater , Ampule Sealer , Borosilicate Culture Tubes (16Mm×100Mm×150Mm) With Tfe Lined-Screw Caps , Parafilm Tape , Determine The Permeability Of Magnetic Materials By Plotting Its B-H Curve. Trainer Operated On 230V With 10% Variation, Sufficient Number Of Patch Cords, With Computer Lead, 12 X 8 With Shock-Proof Ply Box, Three Different Values Of Capacitors Are To Be Given On Board. • One Variable Potentiometer • Different Circuit Diagram Is Printed On Board. • Step Down Teansformer With Demonstration Transformer With 2 Secondary Coils And One Primary Coil. • Output Through Bnc Connectors And Bnc Lead Are To Be Provided For Output To Cro. • Components Mounted On The Front Panel. , Set Up For Measurement Of Voltage Current And Power Variable Ac Supply: 0-230V, 0-5A, Continuous Variable Ac Supply, Ac Voltmeter: 0-300V, Mi Type, Class : 1.5,Ammeter : 0-5A, Mi Type, Class : 1.0 96 Sq. Mm. (Ae Make), Wattmeter:230V,5A, 1000Watt, Analogtype, Panel Mount, Load : 0-5A, 220V Resistive Load, Step Variable, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords, Operating/Instruction Manuals. , Set Up For Visualization Of Phase Difference Between Voltage And Current In Series R-L And Series R-C Circuit Analog Meters: Ammeter 20Ma Ac.Voltmeter 20V Ac. Components Are Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch. Dso- 2Channel, 50Mhz Table Top-1No. , Measure Voltage, Current, Power, P;Ower Factor In A R-L Series Circuit Resistance: 0 - 500O / 2A, Step Variable, Inductance: 0-200Mh / 2 Amps, Step Variable, Voltmeter: 0-300V Ac, Digital Panel Type– 4 Nos.Variac: 0-250 Volts / 4 Amps, Panel Mount Type, Single Phase, Ammeter ; Digital Panel Type. 0-2A Ac Wattmeter:- 230V/5A, 1000Watt Digital Panel Mount, All The Meters Mount On Bakelite Panel Board With Toggle Switches, Terminals, Connecting Wires, Rotary Switches, Sockets, Operating Manual Etc. , Identify Different Parts Of A Single Phase Transformer, Ac And Dc Motor. Dc Machine-0.5Hp, 220 Volts, 1500 Rpm, Compound Wound Dc Machine. Parts I.E. Armature, Shunt Field, Series Field, Commutator, Carbon Brass, Carbon Holder, Carbon Rocker, Ball Bearing, Bearing Lubricant, Bearing Guards, Cooling Fan Etc. Are Properly Paints And Marking For Easy Understanding. Three Phase Induction Machine (Squirrel Cage)- 1 Hp Capacity, 415 Volts, 1460 Rpm, Three- Phase Sq. Cage Induction Motor. All Parts I.E. Stator Winding, Sq. Cage Rotor, Cooling Fan Are Properly Paints And Marking For Easy Understanding. (Each Set) Transformer (1-Ph) : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, An Cooling– 1 No. , Determine The Transformartion Ratio Of A Single Phase Transformer And Measure No Load And Full Load Current Transformer : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, Normally Air Cooled, Variac:Single Phase, Panel Mount Type, 0-250 Volts, 10 Amps, Wattmeter : 0-300 Volts / 0-5 Amps, Single Phase, Digital Type (Schneider), Voltmeter: 0-300 Volts, Ac, Panel Mount, Digital Type (Select)– 2 Nos. Ammeter: 0-1 Amps, Ac, Panel Mount, Digital Type (Select) Ammeter: 0-10 Amps, Ac, Panel Mount, Digital Type (Select) – 2 Nos. Load : 0-5A, 220V Resistive Load, Step Variable,– 1Set. All Meters Are Mount On A Self Stand Bakelite Panel Board. All The Terminals Of The Meters Etc. Brought Out On The Panel For Flexible Connection. With Connecting Patch Chords, Operating Manuals Etc. , Identification Of Different Active And Passive Lements In A Given Circuit Different Type Of Resistors, Capacitors, Diodes, Zener Diodes, Transistors (Npn & Pnp Type), Transformers, Inductors,Regulator, Op-Amp Ic, Fet, Mosfet Etc. All Above Mentioned Components Fitted On Acrylic Sheet With Proper Marking And Symbol. , Familiarization With Multimeter To Measure The Value Of Given Resistor And To Confirm With Clour Code Digital Multimeter Meeting Iec1010standard. Ce Resistance:- Different Value Resistance (Cfr And Mfr Type)-1No Each. With Colour Code.Inductor :- Different Value Inductor -1No Each. With Colour Code. Capacitor :- Different Value Capacitor -1No Each. With Colour Code. , Use Of Lcr-Q Meter To Measure The Value Of A Given Capacitor And Inductor • Dual Backlit Lcd Display. Auto Lcr Smart Check And Measurement. Series/Parallel Modes Are Selectable. • Ls/Lp/Cs/Cp With D/Q/ T/Esr Parameters. Support Dcr Mode 200.00O~200.0M?. Five Different Test Frequency Are Available: 100/120/1K/10K/100K Hz. • Test Ac Signal Level: 0.6Mvrms Typ. Test Range: (Ex. F=1Khz). L: 200.00 ?H ~ 2000.0 H. C: 2000.0 Pf ~ 2.000 Mf. R: 20.000 O ~ 200.0 M?. • Multi-Level Battery Voltage Detector Support. Back-Light & Buzzer Sound Driver. • Parameters Displayed: Dc Resistance, Serial Inductance, Parallel Inductance, Serial Capacitance, Parallel Capacitance, Serial Resistance, Parallel Resistance, Phase Angle, Equivalence Serial Resistance, Dissipation Factor, Qqquality Factor. Capacitor:- 2.5Mfd, 2.25Mfd/400Volt-1No. Each. Inductor:- 10Mh, 4.7Mh. -1No. Each. , Test The Pn Junction Diode Using Digital Multimeter And Finding Out Their V-I Characteristics In Forward Bias. Ammeter:15Ma/150Ua Dc Panel Mount-1No., Voltmeter: 3V/30V Dc Panel Mount-1No. Power Supply: Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No. Components Are Fixed On The Kit. Silicon Diode _1N4007)-1No., Germanium Diode-1No.,Two Different Voltage Zener Diode-1No.,Voltage Control Through Potentiometer-1No. Digital Multimeter Meeting Iec1010standard. Ce , Identify The Terminals Of A Transistor Using Digital Multimeter And Calculate Gain In Ce Mode Transistor. Transistor- Pnp And Npn Type-1No. Each., Ammeter:- 15Ma/150Ua Dc Panel Mount-1No., Voltmeter:- 3V/30V Dc Panel Mount-1No. Power Supply:- Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No., Digital Multimeter , Realization Of Truth-Table Og Different Logic Gates(Ttl) And Verification Of De-Morgans Theorem . Fixed Dc Power Supply Of 5 V /250 M A. . One Output Indicator For Taken The Observations And Two Toggle Input Selectable Switches For Selects 0 And 1 Logics. . Or Gate, Not Gate, And Gate, I C’ S Are Mounted On The Front Panel. . User Manual And Connecting Leads Are Also Provided With This Instruments.
Contract Date: Dec 30, 2024 Contract Value : 51.88 Lakh
Government Departments No of Bidders 36
West Bengal View Result →
50.
Defence #6886994 AOC
Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date: Feb 25, 2025 Contract Value : 47.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
TenderDetail
Loading tenders