View Bid Results For Electromagnetic Testing Tenders

We found 471 Bid Results related to electromagnetic testing tenders. You can find Contractor details who won electromagnetic testing tenders along with contract details in Bid awards announcements section.

Filters
Stage
379
52
40
Tender Publishing Platform
75
396
State / UT
28
105
58
52
25
23
21
19
18
18
16
14
14
14
11
10
10
7
7
6
5
4
3
3
2
2
2
1
1
Contract Value
155
84
152
79
Publish Date
2
0
0
0
0
Sector
25
100
70
61
48
33
31
29
27
13
8
7
7
6
5
4
4
4
3
3
2
2
1
1
1
1
Ownership
6
274
75
73
47
1
1
Within keyword
Active filters:
Showing 1–10 of 471 tenders matching your filters
1.
Power #11494630 Technical Bid
Tender For Biennial Maintenance Contract (Bmc), Form 01.08.26 To 31.07.28, Under Testing Department At Sgtpp-1. Cleaning Of All Control And Protection Related Panels And Equipments. 2. Assistance In Troubleshooting, Rectification, Minor Repairing Of All Type Of Electromagnetic Relays, Static &Numerical Relays. 3. Assistance In Troubleshooting, Rectification, Replacement Or Repairing As Required For Control Circuit, Electrical Measuring Instruments (Meter); Switches; Electrical Transducer, Oti,Wti Transmitter, Annunciator; Control Fuse; Contactor And All Other Associated Equipments/Items Inside The Panels In All Related Area. 4. Assistance In Testing Of Different Relays-Voltage, Current, Frequency, Power, Impedance Etc. 5. Assistance In Testing Of Thermal Over Load Relay, Mcb, Contactors, Timer, Fuse Etc. 6. Assistance In Identification Of Dc Earth Fault At Sgtpp Plant And Rectification Of 220Vdc Earth At The Area Of Testing Department. 7. Assistance In Testing And Calibration Of Meters And Transducer- Voltage, Current, Frequency, Power Factor, Watt,Var, Va Etc. 8. Assistance In Trouble Shooting, Maintenance And Testing Of All Type Of Electronic Modules In All Related Area Under Testing Dept. 9. Assistance In Testing Of All Electrical Installations At Site Or Shop Or Laboratory Such As Generator, Transformer, Circuit Breaker, Ct, Pt, Lightning Arrestor, Motor, Cvt, Reactor, Ngr, Isolator, Control Cable Andpower Cable Etc.Arrangement For Testing Also Be Done By Contractor For Any Location In Sgtpp Area. 10. Assistance In Testing Of Transformer Oil (Bdv, Moisture Content, Tan Delta) Etc. 11. Assistance In Reading Of Static Energy Meter Through Mri Only And Optical Communication Cord By Laptop Also Testing & Calibration Of Different Type Of Energy Meters. 12. Assistance In Testing Of Battery Bank Cells. 13. Assistance To Testing Department Related With Protective Relays, Electrical Instruments, And Different Power Control Panel/Board, System Testing Of All Electrical. Items/Equipment Of 2X300Mw & 2X500 Mw And 1X660Mw Units Of Sgtpp (Plant & Township Areas As Per Direction Of The Controlling Dept.) Like Existing Contract. 14. Shifting Of All Kind Of Testing Instruments And Other Necessary Tools And Tackles From Lab To Site And From Site To Lab Should Be Under The Scope Of Work Of Amc Manpower.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
2.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
5.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
6.
Coal and Mines #11337639 AOC
Bids Are invited for Custom Bid For Services - Electrical Works For Maintenance Of Quarters And Manoranjan Kendra Of Urjagram Colony, Wani Area Under Mission Sehat - Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Light/Bell Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Cw (Materia + Labour) , Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wires, Modular Type Switch And Socket, Earthing And Required Accessories As Per Specification No Wgpw/ Sw (Materia + Labour) , Supplying Modular Type Switch 6A/10A On Provided Plate And Box With Wiring Connections Complete. ( Materia Only) , Supplying Modular Type Switch 16A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type Bell-Push 6A/10A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6A Multi Socketwith Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6/16A Multi Socket With Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying 6A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying 16A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying Flush Type Shockproof Plug Socket 6A & 16A (6 Pin) With 16A Switch Combined With Indicator L And Fuse With Gang Box On Wooden Board. (Materia Only) , Supplying Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 1.5 Sq.Mm (30 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 2.5 Sq.Mm (50 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying And Erecting Pvc Insulated Pvc Round Sheathed Fr 4 Sq.Mm (56 No. X 0.30Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 4 Sq Mm Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying Hms Pvc Conduit 25Mm Dia. With Pvc Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 20Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 25Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Material Only) , Supplying Pvc Box Trunking Of Size 50X50mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Box. (Material Only) , Supplying Gi Flexible Conduit 25Mm Dia. Conforming To I.S. With Required Number Of Couplings, Bushes, Check Nuts Etc. Complete (Material Only) , Supplying Spmcb 6A To 32A, C-Series With Rated Short-Circuit Breaking Capacity(Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Sp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Dp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Fp Mcb 40A To 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying 4 Pole Isolator Only Switch Version Of Miniature Circuit Breakers Of 80/100A In Provided Distribution Board. (Material Only) , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 8 Ways (8 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Supplying & Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 10 Ways (10 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection Provided On Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Providing, Erecting And Commissioning 2 Pole Rccb Only Of Electromagnetic Type With 30/100/300 Ma Sensitivity And Having Capacity Of 40A Complete As Per Specification No. Swrccb/ Rccb (Material Only) , Providing & Erecting 3 Pole Mccb, 415V, Up To 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magneticsetting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact.Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu) Adjustable Thermal Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 630A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Supplying & Erecting On Load Change Over Switch 4 Pole, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3 As Per Specification No. Sw-Swr/Cos. (Material + Labour) , Supplying, Erecting, Testing & Commisioning Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Accuracy Class 1.0 With Backlit Lcd Display, (Measuring And Display Kwh, Kvah,V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weatherproof Pvc Wires Duly Tested By Electric Supply Company. , Providing Temporary Illumination Consisting Of White/Colour Series Lights With 8Mm Led Miniature L S Of 2 To 3.4V [1000 Nos] With Cap With Required Switchgears Erected And Dismantled With Rotor Effect As Approved With Scaffolding, Up To Three Days As Per Specification No. Te-Il/Srl (Material + Labour) , Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Upto 16A To Use Independently Or In Conjunction With Contactor. (Material + Labour) , Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On And Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer Erected In Provided M.S. Box. (Material + Labour) , Supplying And Erecting Four Pole Power Contactor 430V, 40A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. (Material + Labour) , Supplying 12 V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged Complete With 36 Months Warranty Complete (Material Only) , Supplying, Erecting, Testing & Commisioning Of Required Size Electrolyte Copper Bus Patti Or Bar Tin Plated In Bus Bar Chamber/In Panel Or Any Other Purpose, Suitable For 500 Volt With Require Capacity Having Thermal Conductivity Of 400W Per Meter With Composition Pure Copper 99.9% Current Density 1.8 With Fixing Arrangement (Like Lug Or Bottle Type Lug) To Both The End With High Grade Polyolefin Insulation Sleeve Complete As Per Specification No. Cp-Bb (Material + Labour) , Supplying Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block/Sunmica Block Of Suitable Size (Material Only) , Supplying Electronic Type Cordless Call Bell Erected On T.W. Board Having Portable Bell Push Working On 9V D.C. Battery And (Effective Range Upto 45 Meter) Bell On 250 V A.C. Supply. (Material Only) , Supplying 5W-7W, 230V Integral Type Led L Suitable For B-22/E-27 Base. (Material Only) Fg-Lp , Supplying 10-12W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying 18W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying & Erecting Integral Post Top Lantern Fixtures (Light House Type) Suitable Upto Led 18 W L Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole/ Bracket As Per Specification No. Fg-Odf/Ptl. (Material + Labour) , Supplying Pvc Surface Modular Double Mounting Plate 3 Modules Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 6 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 8 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 16/18 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Complete.(Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 16/18 Module Complete. (Material Only) , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E Class Insulation. (Material + Labour) , Making Trench In Soft Soil Having 0.75M Depth And Minimum 0.3M Width For Laying Provided Cables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr , Supplying 6 To 32A, 10Ka, Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. (Material Only)
Contract Date: Ref. Documents Contract Value : 6.45 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
8.
Drinking Water Supply and Sanitation #11312834 Technical Bid
Tender for Online Multi::Parametric Cod, Bod, Tss And Ph Analyzer With Gprs Data Transmission To Cpcb/Spcb Portal Supplied With Spectrophotometry Sensor (Cod, Bod, Tss), Ph::Lyser (Ph) And Con::Cube Terminal Make: S::Can, Austria , Electromagnetic Flow Meter Upto 20 Inch Make: Badger/Abb Description Product Type: 1M - M1000 Certification: A - General Safety/Purpose Meter Size: 180 - 18 / Dn450 Process Connections: Faa - Asme: Class 150 Flg: Rf Base Material: C1 - Carbon Steel Liner Material: P - Ptfe Electrodes : A - Hastelloy C-22 (Standard / Measuring, Empty Pipe And Grounding) Grounding Rings: X - No Gnd Rings Meter Lay Length: S - Standard Transmitter: Sa - Sensor Mount: Local Dsp: Al Encl: Ip67 Power Supply: Ab - 9-36V Dc Hardware: C - M20 Thrd: Poly Cable Glands Junction Box: X - None Remote Cable Length: Ww - None Input/Output Channel: Dba - Std Input/Output Communications: R - Std Comms Wiring Method: Xx - None Std Programming: Ea - Standard (Default Metric Units) Testing And Tagging: F - 0,3%: 3-Point: Factory Calibrated , Operation And Maintenance During Defect Cum Liability Period , Operation And Maintenance For First Year After Defect Cum Liability Period , Operation And Maintenance For Second Year After Defect Cum Liability Period , Operation And Maintenance For Third Year After Defect Cum Liability Period , Operation And Maintenance For Fourth Year After Defect Cum Liability Period , Operation And Maintenance For Fifth Year After Defect Cum Liability Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
10.
Railways #11302070 AOC
Supply Of wire rope hoist of 2t capacity , wire rope hoist of 2t capacity confirming to is-807,3938 with hoist carrier for c t movement to suit 150 mm rail width as per the following specification. equipment : electri c wire rope hoist; capacity : 2000 kgs ; duty & class : class iv heavy duty; height of lift : 5.0 mtrs; rail size : 150 mm width, 450 mm height ; hoist head room : 900 mm ; hoist speed : 3 mpm; ct speed : 12 mpm; hoist motor : squirrel cage induction motor 5 hp with brake , tefc sq. cag e induction motor 3.7kw / 5hp , 4 pole , class f insulation , 415v , 3 ph , flange mounted , fram e size 112m with dc operated electromagnetic brake of minimum braking capacity of 5 kgm, c ontinously rated; ct motor and brake specifications :squirrel cage induction motor power : 0.37 kw , pole : 4, efficiency : ie3 , frame : 71m , mounting : b5 flange , brake : electromagneti c disc type spring loaded ac fail safe brake of min torque : 0.6kg.m; voltage : 415v , phase : 3 phase , compressed spring length : 40 mm , air gap : 0.5 mm; hoist & ct gearbox : helical / spu r gear combination. all gears inside the gearbox shall be of en-24 material with hardness o f 40-45 hrc. mtc and htc from nabl accredited lab should accompany the supply. wire rope : round strand steel wire rope conforming to is 2266 latest and is 6594 latest size : 10mm or 12mm , 4/1 falls construction : 6 x 36 . drum : seamless pipe of suitable dia & shell thickness to accommodate wire rope single layer as per is-2062; hook : forged heavy duty single shan k typeplain hook as per is-3815, 360 swivel type with spring loaded safety latch. control pan el :consists of mcb, olar, fuse, etc. note: (a) test certificate for hook shall accompany the supply (b) make of bearings: skf/ntn/fag/timken only. (c)the firm shall furnish inspection cer tificate from manufacturers or their authorised testing agents preferably incorporating the details of traceability of the bearing. (d) all gears inside the gearbox shall be of en-24 material with hardness of 40-45 hrc. mtc and htc from nabl accredited lab should accompa ny the supply (e) make of motors: ngef / abb / lhp / cg / hem /bharat bijlee only; (f) make of ele ctricals: siemens/ge/alstom/l & t/abb only ;control voltage: 110v ;supply voltage: 400/440v, 3 phase 50 cycles. (g) guarantee: 12 months from the date of commissioning or 18 months fr om the date of supply, whichever is earlier. [ warranty period: 18 months after the date of deliver y ] ]
Contract Date: Jun 17, 2026 Contract Value : 2.15 Lakh
Government Departments No of Bidders 1
11.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
12.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
14.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
17.
Drinking Water Supply and Sanitation #11205084 AOC
Tender for N.S. Item , Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Raw Water Having Head 12 M As Per The Indicated Requirements Of Discharge In 2400 Lpm And Power Capacity In Bhp As Per Is Marked. , Providing And Fixing Battery Powered Full Bore Electromagnetic Flow Meter 300 Mm I/D With Inbuilt Gprs (Inline Flange Type) , Providing , Installation And Commissioning Of 150 Wattage Led Lights Outdoor With Lamp Operation Mode On, Off Light Source High Power Smd Led, Lamp Life Span Of Leds Used In The Luminaire Shall Be 0 ) 50000 Hours. @L L70 ,Color Rendering Index (Cri) Of The Leds Used In The Luminaire Shall Be ) 70 Including Cost Of All Accessors Wiring And Other Material Complete In All Respect. , Ns Item-Providing, Installation And Commissioning Of 100 Wattage Led Lights Outdoor With Lamp Operation Mode On, Off Light Source High Power Smd Led, Lamp Life Span Of Leds Used In The Luminaire Shall Be 0) 50000 Hours. @I L70 Color, Rendering Index (Cri) Of The Leds Used In The Luminaire Shall Be ) 70 Including Cost Of All Accessors Wiring And Other Material Complete In All Respect. , Less Credit For Ci Special , Less Credit For Nrv, S/V , Less Credit Of Old Pumping Set In Existing Damaged Conditions 2000 Lpm X 12 Mtr , Less Credit Of Old Starter In Existing Damaged Conditions For Pumping Set Of 2000 Lpm X 40 Mtr , Less Credit Of Old Starter In Existing Damaged Conditions For Pumping Set Of 2000 Lpm X 12 Mtr , Less Credit Of Old Pumping Set In Existing Damaged Conditions 2000 Lpm X 40 Mtr....... , Item Description , Hsr Item
Contract Date: Jun 13, 2026 Contract Value : 2.85 Crore
Government Departments No of Bidders 9
18.
Educational and Research Institute #11203813 Technical Bid
Tender For Selection Of System Integrator For Supply, Establishment, Operation And Maintenance Of Center Of Excellence On Digitalization Through Simulation At Government College Of Engineering, ,Amravati - Hardware Part , Battery Charge And Discharge Test System , Data Acquisition And Logging System , Thermocouple Rtd For Temperature Measurement , Battery Tester For Internal Resistance Testing , Electric Vehicle Bldc Motor Training System , Bldc Brushless Inner Rotor Brushless Dc Motor Coupled , Battery Characteristics Training System , Pmdc Motor Training System , Power And Transmission System Study Models For Ev Application , Pmsm Motor Coupled With Dc Generator Test Bench Setup , Switched Reluctance Motor Coupled , Pwm Charge Controller Training System , Sectioned Electric Vehicle Twowheeler Chassis , Sectioned Electric Vehicle Fourwheeler Chassis , Battery Resistance Spot Welding Machine , Dc Ac Clamp Meter , Noncontact Type Tacho Meter , Computing Workstations For Ev Design And Simulation , Multibody Dynamics Analysis Research Software Bundle For Ev 10 User , Power Train Gearbox Design Research Software Package , 1D3d Thermal Modelling Bms Modelling Electric Motor Ic Engine , Multiphysics Cae Research Software Package , Nmc Cell Size 18650 , Nmc Cell Size 26650 , Lfp Cell , Smart Bms Training System , Electric Vehicle Scanner , Diy Kits For 20 Students , Advanced Driver Assisting System Adas Training System For Emobility , Ac Ev Charger 10Kw , Dc Fast Charger 20Kw , Multifunction Installation Tester , Electric Vehicle Service Equipment Test Adapter Kit , Battery Tester With Inbuilt Printer , Digital Infrared Thermometer , Digital Multifunction Meter With Vfd Efdetection 3Phase Rotation , Vde Approved Insulated Tool Set For Ev , Electric Vehicle Safety Equipment , Ev Battery Assembly Testing Centre Setup , Ev Battery Pack Cell Equalizer , Regenerative Charging And Braking Training System , Ev Assembly Disassembly Kit , Three Phase Power Clampon Meter With Harmonics Measurement , Digital Insulation Multi Function Meter , Phase Sequence Indicator , Battery Quality Anaylyzer With Data Logger , Hybrid Display Module , Hybrid Trainer Module Motorized , Professional Wall Charts Approx 4 Ft 3 Ft , Professional Lab Layout And Design , Engineering Simulation Software Multiphysics Cae Research Software Includes Preprocessor And Post Processor 10 Users , 3D Cad Package 60 User , Professional Wall Charts , Professional Lab Layout And Design , Video Conferencing Setup , Electromagnetic Em Simulation , Integrated Circuit Ic Design Verification Academic Research Software , Soc Development Board With Software , Emcemi Test Equipment , Spectro Radiometer For Measurement Of The Luminous Flux Spectrum Color , 3D Printer For Prototyping , Professional Wall Charts Approx , Professional Lab Layout And Design , Revolving Chair With Arm Centre Pivot Mechanism , Computer Table , White Board With Stand , Revolving Office Chair With Arm Centre Pivot Mechanism For Faculty , Laboratory Wooden Table , Office Table For Faculty , Major Almirah With Glass Type Doors , Seminar Chairs With Desklet , Executive Office Table , Executive Office Chair , Sofa Set 321 Seater , Teapoycoffee Table , Visitors Chairs With Cushion , Major Almirah , Multi Function All In One Printer For Office And Lab , Necessary Electrification And Networking , Matting Area With Labour Work In Sq Ft , False Ceiling In Sq Ft , Window Sliding Door In Sq Ft , Window Curtains With Fitting In Sq Ft , Gypsum Plaster With Wall Putty In Sq Ft , Wall Coloring In Sq Ft , Air Conditioner 2 Ton , Cctv Camera , Interactive Board , Partitions Cubicles In Sq Ft , Training Support Part , Centre Incharge (Annual Cost) , Lab Operator (Annual Cost) Ev Lab , Faculty Training Ev Lab , Lab Operator (Annual Cost) Simulation Lab , Faculty Training Simulation Lab , Lab Operator (Annual Cost) Esdm Lab , Faculty Training Esdm Lab
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
19.
Tourism #11175186 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Supplying And Filling In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. Moorum , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-30 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. I.Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing And Fixing Exposed Laterite Stone Of 100 Mm Thk For Dado ,Laid On Cement Mortar Paste 1:4 (1 Cement : 4 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Stone Including Rubbing Including Applying Acrylic Varnish Etc Complete. As Per Designs And The Directions Of The Engineer-In-Charge. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete. 600X 600 Mm Dark Shades , Providing And Laying Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Lakha Red , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid . Plain White Makrana Slab 25Mm Thick , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : White Makrana Marble , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete). , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 30 Cm Lx 40 Cm H X 15 Cm T , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Steel Bars & Disposal Of Unserviceable Within 50 , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. 12 Mm Cement Plaster 1 :3 ( 1 Cement : 3 Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surfaces Etc. 50 X 12 Mm , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 250 X 16X 5Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete , Providing And Applying Decorative Plastering For A Window Sorrounding, Using 1:4 Morter Mixture With Bricks Chips,Featuring A 300Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer. (The Job Involves Applying A Decorative Finish Over Underlying Structure, Incorporation Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Double Piller At The Corner (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center For Hall(Ht 2.10 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 200Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Arch Of Span Of 3Mt., Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering Ofr Cornice At Ceiling In Hall Of Ht 0.40Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Construction And Installation 6Mt Height Replica Of Shree Suptakoteswar Stumb Using Sadhahalli Grey Granite Stone With Intricate Carvings, Moulding As Per Drawing. The Structure Should Have 6Mt Ht. With 2.5 X2.5X0.70 Mt Ht At Base And Stumb Of 1.50X1.50X5.25 Mt Height At Top As Per Details Drawings And Direction By The Engineer. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A 150Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Padma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Cornice ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Adhopadma For Sajja), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Electrical Works , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 1/2 Core 70Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 70 Sq. Mm. , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(K) 12 Way (8+36), Double Door, Horizontal Type Cat B , Supplying And Fixing 40 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C -- With Cat B Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.A) 20 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.B) 25 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Requiredd) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Requireda) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredb) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(C) 6 Module (200Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredsitc Of Wall Fan,600 Mm Sweep, With All Accessories. , Supply Installation Testing And Commissioning Of 8-10 W Spot Light Cob Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supply Installation Testing And Commissioning Of W 80W Flood Light Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =600X1500(H),Lamp Base- G9, Wattage- 7X42w Max, Complete With All Accessories. , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =1200X1500(H),Lamp Base- G9, Wattage- 12X42w Max, Complete With All Accessories. , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineerincharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately). , Supply Installation Testing and Commissioning of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 400Mm. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo Separate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip65, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of Aluminium Profile For Neon Flex , Supply Installation Testing and Commissioning of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv , Supply Installation Testing and Commissioning of High Quality Dmx Decoder, Power Input : Dc 24V , Supply Installation Testing and Commissioning of Pvc Insulated Multi Core Electrical Un Armoured Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete For Both Power And Dmx. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of Ip65 I Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System Quick Lock High Impact Materials - Long-Lasting And Reliable , Supply Installation Testing and Commissioning of Ip65 I Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Female Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options. - 12 Nos Of 6/10A Sp Outgoing Mcbs. - 1No Of 32A Tpn Incoming Mcb. , Supply Installation Testing and Commissioning of Ip Driver Box Made Up Of Pvc / Upvc And Ivory Connectors For The Internal Terminations And External Outgoing Connecting Points, Fiber / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. , Supply Installation Testing and Commissioning of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. , Supply Installation Testing and Commissioning of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. , Supply Installation Testing and Commissioning of Programming Charges , Supply Installation Testing and Commissioning of Additional Accessories For Installing The Lights As Per The Final Drawing/Site Condition Consisting Of Clamps, Brackets, Angles, Conduits, Joints, Hardwares Like Fasteners, Nut & Bolts Etc., , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 100A Tpn Mcb As Incommer And 11 Nos Of Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based Programmable Digital Almac Timer As Directed By Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
21.
Housing Urban and Rular Development #11118160 AOC
Tender For Modular Operation Theatre Items At Sadar Hospital, Jamtara At Jamtara For The Year-2025-26 , Wall And Ceiling Cladding (Approved Makes: Jindal/Tata/Essar) Prefabricated Wall & Ceiling Prefabbicated Modular Operating Theater Using Ppgi Puf Panel (Both Wall & Ceiling) Providing Of Pre-Fabricated Modular Operation Theater With Ppgi Puf Pannel Filled With Puf Of 40 Kg/Cubic Meter (40D) Having Required Mechanical Strength And Better Thermal Insulation Which Saves Energy Construction The Panels Joints Are Properly Cam Locked & Revisited Which Provides A Seamless Sub- Structure Which Again Sanded To A Smooth Finish. Approx. Thickness For Wall 50 Mm, Raiser 40 Mm. And Ceiling 30Mm. , Laminar Air Flow System Supply Installation Testing And Commissioning Of Ceiling Filtration System 2400 X 2400 Mm. The Ceiling Filtration System Shall Be 2.40 Meters X 2.40 Meters And Will Be Integrated With The Adjacent False Ceiling. The Ceiling Shall Be Constructed With A Plenum Box Supplied With Conditioned Air From The Central System Via 8 Nos.Hepa Filters (European Norm En1822:2009; Class H14; Dop 99.97-99.9999% Efficincy For 0.3 Micron Particles) With Pressure Drop Of 300 Pascals At Its Nominal Flow Rates (Supplied With The Plenum), Mounted On The Exit From The Supply Ducting. , Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Weled With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Hermetically Sealed Sliding Door System Fabrication Supply, Installation, Testing & Commissioning Of Sliding Type Hermetically Sealed Ot Door Having High Density Partical Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Size:1800 X 2100 Mm.(Wx H). Automatice Doors: Provided With Radar Switch- 2 Nos., Foot Switch Nos. And Photocell Sensors (Anti Crush Feature) & As Per Tech. Specs.Attached. Automatice Doors Size:(1800 X 2100 Mm.) , Peripheral Lights Supply Installation And Commissioning Of 42W Bottom Opening Room Fixture With Ip 65, Led Make Should Be Nichia/Seoul5 Sdcm, Own Make Bis Certified Islocated Driver, Flicker Free, Class2 Selv Driver, Operating Temperature:-100C To 450C Operating Voltage Range:140-270V, Surge Protecction 3.5 Kv, High Effciency Driver:80-85%, Low Voltage Cut Off Below 130V, Output Short Circuit Protction, Fixture Made Up Of Ms Power Coated White After Phosphochromate Treatment Provided As Standard With Sheet Thickness Of 1.2 Mm. Diffuser Of High Impact Polycarbonate Opal Diffuser With Thickness 1.5Mm For Glare Freeuniform Light Distribution, Power Coating: 60Microns, Lamp Source: High Efficiency Long Life Led Package In Integral Module To Ensure Better Uniformity, Average Life L70b50: 50000 Hours,Thd10%,95, System Efficacy 95-100 Lm/W, Cri80, Ip65, Ik05 Impact Rating, Dimension Will Be , Surgeon Control Panel Supply, Installation, Testing & Commissioning Of Operation Theatre Control Panel Membrane Type: Time Day Clock Time Elapse Clock General And Rgb Lighting System Conntrol (Peripheral Lights And Plenum Lights With Dimming) Medical Gas Alarm Panel 5 Gas- Low, Normal And High Pressure With Sequencing As Per Htm 02 01 Hand Free Telephone Set With Speaker Temperature & Humidity Indicator With Controller Hepa Filter Status Module Room Pressure Indicator/ Differential Pressure Indicator , X-Ray View Screen Supply Installation, Testing & Commissioning Of Twin Plate Led Xray Viewing Screen: Size:940 X 640 X 50 Mm. Approx With Viewing Area, Two Plate X-Ray View Screen (120W), Led Based Technology With Colour Temperature6000k And Lamp Life50,000 Hrs And Brightness In Excess Of 4000 Lux. , Writing White Board Supplying & Fixing Of Sturdy Writing Operating List Board: Made Of Ceramic Surface Having Magnetic Properties And Should Be Flushed To The Wall Of The Operating Room Size 940Mmx 640Mmx 50Mm , Surgeon Pendant Providing & Fixing Of Ceiling Mounted Single Arm Pendant Systems For Surgeon: The Weight Carrying Capacity Of The Arm Should Not Be Less Than 180 Kgs. Load. There Should Be 5 Or 6 Nos. Equipment Loading Shelves. Double Column Of 1000Mm. Single Arm Pivot Range Minimum 900 Mm. Or Above. The Brake (Electromagnetic) Supplied With Indian Origin Multipin 6/16 Annual Periodical Maintenance Electrical Switch+Socket-5Nos. It Should Have 2 No. Rj 45 Data Socket. It Should Have Provision For 06 Gas Outlet Points 2 Oxygen 1 Sa7 1Co2 1 Vacuum Capable Of 340 Degrees Of Rotation. Medical Gas Terminal Units Shall Be Provded By The Mgps Vendor And Shall Be Installed In The Pendant. Usfda , Anesthesia Pendant Ceiling Mounted Rigid Pendant Systems For Anaesthesia: Single Arm Motorized Type Pendants Made Of Aluminum, Powder Coate Dimensions: Double Vertical Column 1200 Mm. Vertical Lift:600 Mm. Horizontal Arms- Total 1000 Mm. Pendant Should Be Prepiped Provided With 5 Nos. Medical Gas Outlets. Outlets Shall Be Connected To Dual Circuit Being Provisioned For All Ozygen 2 Outlets. Nitrous Oxide 1 Outlets Vacuum 1 Outlets. Medical Air 1 Outlets Agss 1 Outlet Colour Coded High Pressure Tubing For Each Gas With Nist Connectors At Ceiling Provided With Prewired 10 Nos 6/16 Amps Sockets And Two Data Sockets Rj45 Instrument Loanding Capacity 180 Kgs. Shelves: Two With Handle And Two Rail Each With Capacity Of 40 Kgs. Drawers One With Handle And Twe Rails Load Capacity 40 Kgs. Swiveling Stainless Steel Vertical Pole , Air Conditioning System: Ahu Supply, Installation & Commissioning Of Air Handling Unit Make: Vts (8.5Tr) (Out Door Unit Make: Blue Star / Carrier) , Aluminum Duction 22 Gauge With Curves & Bends Where Indicated For Easy Flow Of Air Tight By Applying Silicon Sealant After Fabrication. Hangers Will Be Provided To Ducts & Will Be Suspended Be Means Of G.I. Coated Rod & These With Not Be More Than 2.5 Mtr. Apart. Thermal Insulation With 19Mm. Xpe With Aluminum Foil For Supply & 13Mm. Xpe Return Air Ducts. Joints Will Be Lapped With Nitrile Tape For Better Insulation. (Laminar To Ahu & Return Air In All Four Corners) Ahu To Be Placed Near Ot, Not More Than 6 Meters. , Dustbin (Trio) , Storge Unit: Storge Unit: 1 Mm. Thick Stainless Sheet 304. The Storge Unit Should Be Divided 4 Equal Parts And Eachpart Should Have Indivdual Swing 8 Mm. Toughened Glass Door With Quality Stanless Steel Self- Closing Hinges Capable Of 180 Degree Swing Out And Secure Locking System. Each Part Will Be Provided With Removable Stainless Steel Racks Made From½ Circular ( Outer Diameter) Seamless Stniless Steel 304 Tubes Of 1 Mm. Thickness Placed At Intervals Of 1.5 Center To Center. The Overall Dimension Of The Stroge Unit Shall Be 1500 Mm. (Width) X 2100 Mm. (Height) 350 Mm. Depth Being Variable To Suit Architectural Layout. , Supplying, Installation, Testing & Commissioning Of F Floor Mounted, Scrub Station: Compact Surgical 2 Bay Scrub Sink Designed For Use In Ot Complex. Each Fixture Fabricated From Heavy Gauge 1 Mm. Thick Type 304 Stainless Steel Of Seamless Welded Construction, Polished To A Smooth Finish With A Front Access Panel Which Should Include, Stoppers And Strainers. Hands Free Operation Should Include Infra-Red Sensors With Built-In Range Of Adjustment. Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature. User Defined Setting Of Approximately 1 To 3 Min Should Be Available. (Size 1500Mm. X 675Mm. X 1105Mm. For 2 Persons , Electrical Db Supply Installation Testing And Commissioning Of Electrical Distribution Board: Should The Trandformers, If Any, Mains Failure Relays, Electrical Distrition Equipment And Circuit Protection Equipment For All Circuits Within The Operating Theatre. All Internal Wiring Should Terminate In Connectore With Screw And Clamp Spring Connections Of The Clip-On Type Mounted, On A Din Rail And Labelled With Indelible Propritary Lables, Individual Fuses Or Miniature Circuit Breakers Should Protect All Internal Circuits. , Pressure Relief Damper Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Relief Dampers: Suitably Sized Air Pressure Relief Damper Should Be Placed Endabling Differential Room Pressure To Be Maintained.Counter-Weight Balancing System Should Be Prvided In The Prd To Maintain Positive Pressure Inside The Operation Room , C-9001 Supreme, Sliding Top Electric Table , C-9001 Supreme, Sliding Top Electric Table Led Operating Light Led Operating Light Having Following Specifications:- Maximum Luminance (1M): 160,000+160,000 Lux At 1 M Distance, Electrical Power: 150+90W, Power Consumption 2 X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1 X 3600/ 1 X 3300, Recommended Room Height At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm/650 N, Light Body Weight 9.2 + 7.5 Kgs, Light Body Depth: 1 X 130 Cm / 1 X 140 Cm, Air Shielding Surface 2 X 330 Cm2 Transformers: 2 X 450Va/ 230V/26V, Brightness Regulator 2 X 20- 500Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Done Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs: , Uv System: Uv Rays Are Very Effective In Killing A Large Number Of Pathogenic Organisms Of Bacterial, Viral And Fungi Commonly Seen In Operating Theaters Such As Pseudomonas, Clostridium Difficile, Mrsa And Vre , De- Fumigation System: Fumigation In Operation Theatre Is A Process Of Gaseous Sterillization That Is Used For The Killing Of Micro-Organisms And Prevention Of Micro-Organisms And Prevention Of Microbial Grwth In The Air, The Surface Of The Wall, Or The Floor1.000 De-Fumigation Control Panel Is Installed Outside The Operation Theatre To Monitor The Room Pressure And To Start The De- Fumigation System From Outside The Operation Theatre, It Will De-Fumigation The Theatre In A Given Time And Will Switch-Om The Ahu To Increase Operation Theatre Pressure Without Operating The Surgeon Control Panel , Ot Corridor Area & Ot Complex With Per And Post Area Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Welded With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Antibacterial / Antifungal Paint Providing And Applying Antibacterial Paint The Internal Surface Of The Room Walls Will Be Sprayed With Water Based Liquid Plastic Wall Glaze Or Equivalent Anti- Bacterial Paint, Approved By The Architect To A Mimnimum Dry Film Thickness Of 300 Microns. The Plastic Coating Will Overlap The Floor Covering Ceiling System And Doorframes By 25 Mm. To Provde A Continuous Sealed Surface. The Plastice Coating Will Be Non- Reflective And The Colour Will Be Submitted To The Architect For Approval. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Jun 15, 2026 Contract Value : 1.21 Crore
Government Departments No of Bidders 4
24.
Railways #11019170 AOC
Tender For Electromagnetic Crack Detector With Loading & Unloading System For Testing Of Axles For Vande Bharat Bogies And Other Coach Axles [ Warranty Period: 30 Months After The Date Of Delivery ] , Charges For Comprehensive Amc For Year 1, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 1 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3 8347N003 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 2, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 4 8347N004 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 5 8347N005 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 S.No Description 1 Applicable As Detailed In This Tender Document And In Icf Bid Document, Special Conditions / Annexures Attached With The Tender Document ( If Any ) , And Conditions Mentioned In Technical Specification / Str / Drawings Uploaded Along With This Tender. For Contracts, Irs Conditions Of Contract Wherever Specifically Not Modified In The Above Said Documents Shall Apply. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderer Shall Be A Reputed Manufacturer In The Subject Field. Yes Yes Allowed ( Mandatory ) 2 I ) Tenderer Should Have Supplied At Least 01 No. Of Emcd Machine For Yes Yes Allowed Testing Railway Axle To Govt. / Public Sector / Mncs / Reputed Private ( Mandatory ) Companies. Or Ii ) Tenderer Should Have Supplied At Least 05 Nos. Of Similar Capacity Machines With Minimum 10000Amps In The Past Five Years To Railways And Other Govt. Sectors / Public Sector / Mncs / Reputed Private Companies. Proof For Supply ( Purchase Order, Commissioning And Performance Certificate To Be Attached As Per Annexure A Clause 2 ) . 5. Compliance Conditions Check List S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 In Case Of Indigenous Bidders, Whether You Are Large Scale Industry Or No No Not Allowed Consortia Of Mses Formed By Nsic, If Yes, Have You Indicated Quantum Of Sub Contracts Given To Micro And Small Enterprises ( In Percent Of Order Value ) ? 2 Have You Gone Through The Eligibility Criteria And Submitted All The No No Not Allowed Documents Mentioned Therein? 3 Have You Submitted The Emd Or Bid Securing Declaration As Per Clause 6.0 No No Not Allowed Of Section-I Of Instructions To Tenderers Of Icf Bid Document Version 09. 4 Have You Furnished Financial Capacity As Per Clause 9.2.1 ( Iii ) Of Section-I Of No No Not Allowed Instructions To Tenderers Of Icf Bid Document Version 09. 5 Have You Confirmed For Compliance Of Public Procurement Orders Of No No Not Allowed Department Of Expenditure Regarding Countries Sharing Land Border With India? 6 Have You Submitted The Details Of Location ( S ) At Which Local Value Addition No No Not Allowed Is Made / Proposed? 7 In Case Of Non-Local / Class-Ii Suppliers, Have You Submitted Road Map For No No Not Allowed Setting Up Manufacturing Facilities For Tendered Item Along With The Offer? ( This Is Applicable Only For Items Which Are Not Restricted To Class-I Local Suppliers ) . 8 Have You Submitted Self-Declaration With Respect To Non Debarment Under No No Not Allowed Any Provisions Of Dpiit Rules? 9 Have You Submitted Translated Copy Into English, For All Documents In No No Not Allowed Language Other Than English And All Such Documents Should Be Signed By The Authorised Translator And Notarized In India? 10 Have You Submitted Declaration For Passing On The Input Tax Credit As Per No No Not Allowed Para 2.8 And 2.9 Of Section-Ii Of Icf Bid Document Version 09. 11 Have You Submitted Authenticated Copy Of The Document Authorizing The No No Not Allowed Signatory To Submit Offer And Commit On Behalf Of Tenderers? 12 Have You Furnished The Statement Of Deviations ( Preferably Nil ) ? No No Not Allowed Page 3 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 13 Have You Furnished The Statement Of Equipment & Quality Control? No No Not Allowed 14 Have You Kept Your Offer Valid For The Validity Period As Mentioned In Nit No No Not Allowed Header? Commercial-Compliance S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Firm Should Furnish Gst No. And Hsn Code No. In Their Offer. Yes Yes Allowed ( Mandatory ) 2 The Tenderers Must Submit Emd As Detailed Under Yes Yes Allowed Clause -6 Of Instructions To Tenderers. Tenderers ( Optional ) Seeking Exemption From Payment Of Emd Must Upload The Requisite Documentary Evidence In Support Of Their Claim For Exemption From Payment Of Emd Along With The Offer. Any Offer Either Not Accompanied With A Vaild Exemption Certificate As At The Time Of Tender Opening Or Not Paid Emd Before Tender Opening Shall Be Summarily Rejected. Please See Attached Document ( Icf Tender Condition ) For The Same. 3 Secrity Deposit Sd There Shall Be No Exemption From Yes Yes Allowed Submission Of Security Deposit ( Sd ) For Any Tender Or ( Optional ) By Any Tenderer Subject Exemptions As Detailed In Para- 13 Of General Condition Of Tender. Please See Attach Document ( Icf Tender Conditions For The Same. 4 If You Are Not Mse Or A Consortia Of Mses Formed By Yes Yes Allowed Nsic, Please Indicate Percentage Of Sub Contract In ( Optional ) Execution Of This Tender That Will Be From Micro And Small Enterprises ( In Percent Of Order Value ) With Further Brake Up Of Mse Owned By Sc / St. ( Information Will Be Provided In % Terms With 6 Fields, Micro Owned By Sc, Micro Owned By St, Micro Owned By Others, Small Industry Owned By Sc, Small Industry Ownrd By St, Small Industry Owned By Others. 5 Earnest Money Deposit ( Emd ) : - Regarding Emd, Please Refer To Yes Yes Not Allowed Clause 6.0 Of Section I Instructions To Tenderer Of Icf Bid Document Ver.09 Attached To The Tender. All Bidders Shall Be Exempted From Submission Of Emd In All Tenders, Subject To Submission Of Bid Securing Declaration As Per The Following Para Of Tender Document, Except Those Who Disqualified From Such Exemption As Per Clause 6.2 Of Section-I Of Icf Bid Document Version 09 Have To Deposit Emd As Indicated In The Nit Header Of Tender Document. Offers Received Without Emd From The Disqualified Bidder Shall Be Summarily Rejected 6 Please Enter The Percentage Of Local Content In The Material Being Offered. Yes Yes Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. ( Mandatory ) The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 4 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 7 The Eligibility For A Bidder From A Country Which Shares A Land Border With Yes Yes Allowed India To Participate In The Tender Shall Be As Per Public Procurement Orders ( Mandatory ) Of Ministry Of Finance, Department Of Expenditure. Please Refer Clause 9.8 ( Sub Clause 9.8.1 To 9.8.8 ) Section-I Of Icf Bid Document Version 09. In This Regards I Certify That: I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India: I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority. I Hereby Certify That This Bidder Fulfills All Requirements In This Regard And Is Eligible To Be Considered. ( Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached ) . If Such Certificate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. 8 Goods & Services Tax ( Gst ) : Will Be Applicable As Per Clause 2.0 And All Yes Yes Not Allowed Sub Clauses Of Section-Ii Of Icf Bid Document Ver-09. 9 Bid Securing Declaration: I / We Hereby Understand And Accept That Yes Yes Allowed If I / We Withdraw Or Modify My / Our Bids During The Period Of Validity, Or If I / ( Mandatory ) We Are Awarded The Contract And On Being Called Upon To Submit The Performance Security / Security Deposit, Fail To Submit The Performance Security / Security Deposit Before The Deadline Defined In The Request For Bid Document / Notice Inviting Tender / Tender Document, We Shall Be Debarred From Exemption Of Submitting Bid Security / Earnest Money Deposit And Performance Security / Security Deposit For A Period Of 6 ( Six ) Months From The Date I / We Are Declared Disqualified From Exemption From Submission Of Emd / Sd, For All Tenders For Procurement Of Goods Issued By Any Unit Of Indian Railways Published During This Period. 10 Passing The Benefits Of Itc: I Hereby Confirm Following: We Hereby Declare Yes Yes Not Allowed That In Quoting The Above Price, We Have Taken Into Account The Full Effect Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any Financial Gain / Benefit As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. 11 Security Deposit: Please Refer Clause 13.0 Of Section-Ii Of Icf Bid Yes Yes Not Allowed Document Ver-09. 12 It Is Certified That Our Firm Has Not Been Suspended Or Banned By Indian Yes Yes Not Allowed Railways During Previous Three Years. 13 Public Procurement ( Preference To Make In India ) Policy Is Applicable As Yes Yes Not Allowed Per Clause 16 Of Section-I Of Icf Bid Document. The Procurement Shall Be Done In Accordance With The Extant Instruction Of Dpiit ( Department Of Promotion Of Industry And Internal Trade ) For Make In India Policy. 14 The Bidders Should Quote The Applicable Hsn Codes And It Is The Yes Yes Allowed Responsibility Of The Tenderer To Quote The Correct Hsn Code And Upload The ( Mandatory ) Document. 15 The Warranty Period Shall Be Two Years From The Date Of Issue Of Yes Yes Allowed Performance Certificate ( I.E., Jointcommissioning Note With Three Days ( Optional ) Prove Out Trial + 30 Days Performance Trial ) . During Warranty Period, Preventive Maintenance Shall Be Carried Out On Quarterly Basis, For This Separate Payment Will Not Be Given. The Details Of Preventive Maintenance To Be Provided During Warranty Period Shall Be Indicated By The Tenderer Giving Details Of Type Of Preventive Schedule, Periodicity On Items To Be Checked, Items To Be Replaced And Expected Plant Down Time. Preventive Maintenance Schedules Shall Be Conducted On Weekends As Far As Possible Or Any Other Day Through Mutual Agreement With Consignees. The Details Of Preventive Maintenance Services To Be Provided Under Warranty Shall Be Rovided By The Tenderer In The Following Format At 23.2 Of Technical Specification Attached. Page 5 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 16 It Is Certified That Our Firm Has Not Been De-Listed For Tendered Item By Indian Yes Yes Not Allowed Railways During Previous Three Years. 17 Please Submit The Details Of The Location At Which The Local Value Addition Is Yes Yes Not Allowed Being Made 18 Declaration On Cartel Formation The Definition Of Cartel Would Be As Per Yes Yes Allowed The Competition Act 2002 ( 12 Of 2003 ) . I / We Declare That I / We Are Not A ( Mandatory ) Part Of Cartel With Other Vendors And Have Offered Competitive Rates In The The Tenders. In The Event Of My / Our Offer Suspected To Be Of Collusive Bidding And Cartel Formation, I / We Understand That Purchaser Reserves The Right To Summarily Reject The Offer And To Ban My / Our Firm From Dealing With Railway. In The Event Of My / Our Offer Confirming To Any Aspect Of The Definition Of Cartel, I / We Understand That The Purchaser Reserves The Right To Refer The Matter To The Competition Commission Of India ( Cci ) Which Is A Statutory Body Constituted Under This Act, For Providing Necessary Relief To The Purchaser Who Represent Central Government Organization Serving The Public. In Addition, I / We Are Aware Of The Chapter Vi Of The Act, Which Deals With Penalties. I / We Understand That This Will Be In Addition To Other Rights And Remedies Available To The Railway Administration Under The Contract And The Law Of The Land. 19 Cartel Formation I / We Declare That I / We Are Not A Part Of Cartel With Yes Yes Allowed Other Vendors And Have Offered Competitive Rates In The Tenders. Please ( Mandatory ) Refer Clause 10.11.7 Of Section Ii Of Bid Document. 20 In Case Of Mse Firm Willing To Claim The Benefits Under Public Procurement Yes Yes Allowed Policy ( Preference To Mse ) Order 2012, The Firm Should Upload With Their ( Optional ) Offer, The Proof Of Their Being Mse Registered With Any Of The Agencies Mentioned In Clause 13.1 Of Section-I Of Icf Bid Document Failing Which Such Offers Will Not Be Liable For Consideration Of Benefits Detailed In Para 13.3 Of Section-I Of Icf Bid Document Tenderers Shall Upload Valid Documents As Per Mse Policy Showing That The Enterprise Is Owned By Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs To Claim The Benefit Under This Sub-Classification. For This Purpose Tenderers To Submit Details Of Share Holding Pattern & Controlling Stakes With Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs Duly Certified By Ca, Failing Which It Will Be Presumed That They Have No Claim Under This Sub-Classification. 21 1.Traders / Distributors / Sole Agent / Works Contract Are Not Exempted From Yes Yes Allowed Payment Of Emd As They Are Excluded From The Purview Of The Mse Policy ( Mandatory ) . 2. In Reference To Conditions No.6.1 ( Vi ) Of Section I Of Icf Bid Document, The Exemption Of Emd Is Applicable Only To The Vendors Having Current And Valid Registration With Pcmm Of Any Zonal Railways / Production Unit For Trade Groups 6579. Firm Should Submit Valid Registration Certificate For Proof. 22 Firm To Quote Strictly As Per Specification Attached. Please Go Through The Yes Yes Allowed Other Conditions Mentioned In The Tender With Regard To Arrangements ( Optional ) Before Supply And Erection. 23 The Tenderers Shall Indicate The Details Of Their Jurisdictional Assessing Yes Yes Allowed Officers ( Designation, Address & Email Id ) . ( Optional ) 24 Make In India: As Per Public Procurement ( Preference To Make In India ) Yes Yes Allowed Order 2017, As Amended, Only Class-I And Class-Ii Local Suppliers Are ( Mandatory ) Eligible To Participate In The Tender. Vendors Who Do Not Qualify To Be Class-I Or Class-Ii Local Suppliers Should Not Quote In The Tender As Their Offers Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class-I Or Class-Ii Local Suppliers For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Page 6 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 25 Scope Of Supply : 1. The Scope Of Supply Shall Include Design, Supply, Yes Yes Allowed Installation, Testing, Commissioning And Proving Out, Warranty Of ( Mandatory ) Electromagnetic Crack Detector Equipment On Turnkey Basis, Required For Crack Detection Of Various Types Of Axles As Per En 13261 As Listed In Annexure -E. The Supply Shall Include All The Concomitant Accessories / Equipments As Detailed In The Specification And Other Concomitant Accessories / Equipment, Which The Manufacturer Considers Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include Installation And Commissioning Of Related Equipment, Training Of Personnel In Operation And Maintenance Of Machine As Per Clause 10.1 And Supply Of Technical Documentation As Per Clause 11 Of Technical Literature. 2. The Scope Of Supply Includes Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For Using The Equipment. 26 Please Enter The Percentage Of Local Content In The Material Being Offered. No Yes Not Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Please Download And Peruse The Tender Document Conditions Applicable For No No Not Allowed Tenders Which Is Attached With The Tender. 2 Icf Bid Document Version 9 Dated 01.11.22 Is Applicable For This Tender. No No Not Allowed 3 Material To Be Supplied At Shell Depot No No Not Allowed Other Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tpi Agency, As Per The Clause 16.0 Of Technical Specification Attached. No No Not Allowed 2 Tenderer To Indicate The Address And Place Of Inspection For Tpi Inspection No No Not Allowed 3 The Tenderer Shall Have Capacity To Undertake Comprehensive Annual Yes Yes Allowed Maintenance Contract. ( Optional ) 4 Suitable Warranty Clauses, Bank Guarantee Clauses, Preventive Yes Yes Allowed Maintenance During Warranty, Penalty For Delay In Commissioning, Delay ( Optional ) During Maintenance Other Than The Above Mentioned Shall Be Applicable As Per The Guidelines Issued By General Conditions Of Contract ( Stores ) For M&P Items In Addition To The Warranty Clauses Mentioned Above Whichever Is Stricter. Special Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers May Note That The Ireps Software Is Contiunously Being No No Not Allowed Upgraded And The Forms May Be Subject To Changes. Tenderers Are Advised To Keep Themselves Updated With The Latest Changes, By Referring To The Latest Versions Of User Manuals Available On The Website, And By Taking Notes Of The Messages Sent By Our Ireps Adminstrator From Time To Time. Tenderers Should Also Make Themselves Fully Acquainted With All Available Templates / Forms Before They Submit Their Offer. No Claim Shall Be Entertained From A Tenderer, On Account Of Non Familarity With Any Of The Templates And Form Available On The Ireps Websites. Page 7 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 2 A ) No Manual Submission Of Documents Is Permitted. Tenderers Shall No No Not Allowed Upload All The Documents In Ireps Portal Only. 3 Tenederers Can Upload Individual File Having Capacity Of 3.5 To 3.7 Mb As No No Not Allowed Attached Document However There Is No Llimitation On The Numbers Of Files Which Can Attached. Tenderers Are Advised To Upload The Documents Well In Advance To Avoid Last Minutes Rush And Complication. All Documents Which Are Submitted Should Be In A4 Size To Facilitate Printing. 4 Tenderers To Refer The List Of Mandatory And Optional Certificates To Be No No Not Allowed Submitted Along With The Offer As Per Icf Bid Documents. 5 Please Check Ireps Website Before Submitting Offer, Any Corrigendum To No No Not Allowed The Tender Has Been Issued Or Not.Please Check Ireps Website Frequently For Corrigendum And Ensure Submission Of Offer As Per Corrigendum Issued By Icf 6 The Minimum Local Content For The Local Supplier Of The Tendered Item To Be No No Not Allowed Categorised As Class-I Local Supplier Shall Be 50% And Class-Ii Supplier Is 20% 7 Offers From Different Tenderers Submitted From The Same Ip Address In A No No Not Allowed Tender Shall Be Treated As Suspected Cartel And All Such Offers Received From The Same Ip Address Will Be Summarily Rejected. However Offers Resulting In Same Ip Address Due To Administrative Reason Like Technical / Networking Issue At Cris Server Shall Not Be Treated As Suspected Cartel And The Decision Of The Railway Administration Will Be Binding On All Tenderers 8 Firm To Submit The Clause Wise Compliance / Deviation Description And Past No No Not Allowed Performance Detail As Per The Annexure -A Attached. Technical-Compliances S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers Are Advised To Go Through All The Clauses Of This Document, Icf Yes Yes Allowed Bid Document And Other Documents Attached And Submit Necessary ( Optional ) Documents, Certificates, Attachments, Etc. Along With The Offer To Establish Their Credentials In Support Of Their Claim. If Required, Clarifications Will Be Sought Only On The Documents Submitted And No Additional Documents Shall Be Entertained Post Tender Opening. 2 Firm To Submit The Clause Wise Compliance For Yes Yes Allowed Technical Specification / Deviation Statement And Past ( Mandatory ) Performance Details As Per The Annexure - A Attached. 3 Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Yes Yes Allowed Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For ( Optional ) Using The Equipment. 4 Bidder Shall Train The Minimum Nominated 5 Railway Staff For Operating, Yes Yes Allowed Maintenance For Using The Equipment. ( Optional ) 5 Prove Out At Consignees Works : The Firm Shall Be Required To Demonstrate Yes Yes Allowed The Machine Capability & Prove Out The Various Performance Tests And ( Mandatory ) Claimed Productivity Requirement / Cycle Time On 20 Nos. Of Axles As Listed At Annexure-E At Consignees End For The Period Of Three Days Comprising 8 Hour Shift During Commissioning Of Machine. Undertakings S.No. Description Confirmation Remarks Documents Required Allowed Uploading Page 8 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 1 I / We Also Confirm That If Any Information And Document Submitted Is Found No No Not Allowed To Be False / Incorrect At Any Time, Icf May Cancel My / Our Bid And Action As Deemed Fit May Be Taken Against Me / Us, Including Termination Of The Contract, Forfeiture Of Earnest Money, Security Deposit And Banning / Delisting / Suspension Of Our Firm And All Partners Of The Firm. 2 I / We Also Confirm That Rates And Other Financial Terms Quoted In Relevant No No Not Allowed Columns Of Financial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Should Not Be Considered For Inter-Se Evaluation And Should Be Ignored. 3 I / We Have Gone Through The All Clauses Of This Tender Document And Other No No Not Allowed Documents Such As Icf Bid Document Version 05, Special Condition Of Tenders, Checklist And Technical Specification Uploaded Along With This Tender. It Is Understood That The Tenderer Submitting Their Offer Is Fully Aware Of All The Clauses Of The Above Said Documents And Undertake To Abide By Submitting This Offer. 6. Documents Attached With Tender S.No. Document Name Document Description 1 4235187.Pdf Technical Specification 2 4305772.Pdf Tpi Condition 3 4305380.Pdf Bid Document Ver-09, Dated 01 / 11 / 2022 7. Responsiveness S.No. Description Validity Of Offer: No Deviation From The Offer Validity Period Stipulated In The Nit Header Of This Tender Document Is 1 Permitted. For Additional Conditions Please Refer Clause 12.0 Of Section -I Of Icf Bid Document Version 09. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers ( Designation, Address & Email Id ) . In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy ( Make In India ) Order 2017, Dated 15 / 06 / 2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015 / Rs ( G ) / 779 / 5 Dated 03 / 08 / 2017 And 27 / 12 / 2017 And Amendments / Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm / Dc ( V.N. Satheesan ) , Charges For Comprehensive Amc For Year 2, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 4 8347N004 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 5 8347N005 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 S.No Description 1 Applicable As Detailed In This Tender Document And In Icf Bid Document, Special Conditions / Annexures Attached With The Tender Document ( If Any ) , And Conditions Mentioned In Technical Specification / Str / Drawings Uploaded Along With This Tender. For Contracts, Irs Conditions Of Contract Wherever Specifically Not Modified In The Above Said Documents Shall Apply. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderer Shall Be A Reputed Manufacturer In The Subject Field. Yes Yes Allowed ( Mandatory ) 2 I ) Tenderer Should Have Supplied At Least 01 No. Of Emcd Machine For Yes Yes Allowed Testing Railway Axle To Govt. / Public Sector / Mncs / Reputed Private ( Mandatory ) Companies. Or Ii ) Tenderer Should Have Supplied At Least 05 Nos. Of Similar Capacity Machines With Minimum 10000Amps In The Past Five Years To Railways And Other Govt. Sectors / Public Sector / Mncs / Reputed Private Companies. Proof For Supply ( Purchase Order, Commissioning And Performance Certificate To Be Attached As Per Annexure A Clause 2 ) . 5. Compliance Conditions Check List S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 In Case Of Indigenous Bidders, Whether You Are Large Scale Industry Or No No Not Allowed Consortia Of Mses Formed By Nsic, If Yes, Have You Indicated Quantum Of Sub Contracts Given To Micro And Small Enterprises ( In Percent Of Order Value ) ? 2 Have You Gone Through The Eligibility Criteria And Submitted All The No No Not Allowed Documents Mentioned Therein? 3 Have You Submitted The Emd Or Bid Securing Declaration As Per Clause 6.0 No No Not Allowed Of Section-I Of Instructions To Tenderers Of Icf Bid Document Version 09. 4 Have You Furnished Financial Capacity As Per Clause 9.2.1 ( Iii ) Of Section-I Of No No Not Allowed Instructions To Tenderers Of Icf Bid Document Version 09. 5 Have You Confirmed For Compliance Of Public Procurement Orders Of No No Not Allowed Department Of Expenditure Regarding Countries Sharing Land Border With India? 6 Have You Submitted The Details Of Location ( S ) At Which Local Value Addition No No Not Allowed Is Made / Proposed? 7 In Case Of Non-Local / Class-Ii Suppliers, Have You Submitted Road Map For No No Not Allowed Setting Up Manufacturing Facilities For Tendered Item Along With The Offer? ( This Is Applicable Only For Items Which Are Not Restricted To Class-I Local Suppliers ) . 8 Have You Submitted Self-Declaration With Respect To Non Debarment Under No No Not Allowed Any Provisions Of Dpiit Rules? 9 Have You Submitted Translated Copy Into English, For All Documents In No No Not Allowed Language Other Than English And All Such Documents Should Be Signed By The Authorised Translator And Notarized In India? 10 Have You Submitted Declaration For Passing On The Input Tax Credit As Per No No Not Allowed Para 2.8 And 2.9 Of Section-Ii Of Icf Bid Document Version 09. 11 Have You Submitted Authenticated Copy Of The Document Authorizing The No No Not Allowed Signatory To Submit Offer And Commit On Behalf Of Tenderers? 12 Have You Furnished The Statement Of Deviations ( Preferably Nil ) ? No No Not Allowed Page 3 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 13 Have You Furnished The Statement Of Equipment & Quality Control? No No Not Allowed 14 Have You Kept Your Offer Valid For The Validity Period As Mentioned In Nit No No Not Allowed Header? Commercial-Compliance S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Firm Should Furnish Gst No. And Hsn Code No. In Their Offer. Yes Yes Allowed ( Mandatory ) 2 The Tenderers Must Submit Emd As Detailed Under Yes Yes Allowed Clause -6 Of Instructions To Tenderers. Tenderers ( Optional ) Seeking Exemption From Payment Of Emd Must Upload The Requisite Documentary Evidence In Support Of Their Claim For Exemption From Payment Of Emd Along With The Offer. Any Offer Either Not Accompanied With A Vaild Exemption Certificate As At The Time Of Tender Opening Or Not Paid Emd Before Tender Opening Shall Be Summarily Rejected. Please See Attached Document ( Icf Tender Condition ) For The Same. 3 Secrity Deposit Sd There Shall Be No Exemption From Yes Yes Allowed Submission Of Security Deposit ( Sd ) For Any Tender Or ( Optional ) By Any Tenderer Subject Exemptions As Detailed In Para- 13 Of General Condition Of Tender. Please See Attach Document ( Icf Tender Conditions For The Same. 4 If You Are Not Mse Or A Consortia Of Mses Formed By Yes Yes Allowed Nsic, Please Indicate Percentage Of Sub Contract In ( Optional ) Execution Of This Tender That Will Be From Micro And Small Enterprises ( In Percent Of Order Value ) With Further Brake Up Of Mse Owned By Sc / St. ( Information Will Be Provided In % Terms With 6 Fields, Micro Owned By Sc, Micro Owned By St, Micro Owned By Others, Small Industry Owned By Sc, Small Industry Ownrd By St, Small Industry Owned By Others. 5 Earnest Money Deposit ( Emd ) : - Regarding Emd, Please Refer To Yes Yes Not Allowed Clause 6.0 Of Section I Instructions To Tenderer Of Icf Bid Document Ver.09 Attached To The Tender. All Bidders Shall Be Exempted From Submission Of Emd In All Tenders, Subject To Submission Of Bid Securing Declaration As Per The Following Para Of Tender Document, Except Those Who Disqualified From Such Exemption As Per Clause 6.2 Of Section-I Of Icf Bid Document Version 09 Have To Deposit Emd As Indicated In The Nit Header Of Tender Document. Offers Received Without Emd From The Disqualified Bidder Shall Be Summarily Rejected 6 Please Enter The Percentage Of Local Content In The Material Being Offered. Yes Yes Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. ( Mandatory ) The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 4 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 7 The Eligibility For A Bidder From A Country Which Shares A Land Border With Yes Yes Allowed India To Participate In The Tender Shall Be As Per Public Procurement Orders ( Mandatory ) Of Ministry Of Finance, Department Of Expenditure. Please Refer Clause 9.8 ( Sub Clause 9.8.1 To 9.8.8 ) Section-I Of Icf Bid Document Version 09. In This Regards I Certify That: I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India: I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority. I Hereby Certify That This Bidder Fulfills All Requirements In This Regard And Is Eligible To Be Considered. ( Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached ) . If Such Certificate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. 8 Goods & Services Tax ( Gst ) : Will Be Applicable As Per Clause 2.0 And All Yes Yes Not Allowed Sub Clauses Of Section-Ii Of Icf Bid Document Ver-09. 9 Bid Securing Declaration: I / We Hereby Understand And Accept That Yes Yes Allowed If I / We Withdraw Or Modify My / Our Bids During The Period Of Validity, Or If I / ( Mandatory ) We Are Awarded The Contract And On Being Called Upon To Submit The Performance Security / Security Deposit, Fail To Submit The Performance Security / Security Deposit Before The Deadline Defined In The Request For Bid Document / Notice Inviting Tender / Tender Document, We Shall Be Debarred From Exemption Of Submitting Bid Security / Earnest Money Deposit And Performance Security / Security Deposit For A Period Of 6 ( Six ) Months From The Date I / We Are Declared Disqualified From Exemption From Submission Of Emd / Sd, For All Tenders For Procurement Of Goods Issued By Any Unit Of Indian Railways Published During This Period. 10 Passing The Benefits Of Itc: I Hereby Confirm Following: We Hereby Declare Yes Yes Not Allowed That In Quoting The Above Price, We Have Taken Into Account The Full Effect Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any Financial Gain / Benefit As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. 11 Security Deposit: Please Refer Clause 13.0 Of Section-Ii Of Icf Bid Yes Yes Not Allowed Document Ver-09. 12 It Is Certified That Our Firm Has Not Been Suspended Or Banned By Indian Yes Yes Not Allowed Railways During Previous Three Years. 13 Public Procurement ( Preference To Make In India ) Policy Is Applicable As Yes Yes Not Allowed Per Clause 16 Of Section-I Of Icf Bid Document. The Procurement Shall Be Done In Accordance With The Extant Instruction Of Dpiit ( Department Of Promotion Of Industry And Internal Trade ) For Make In India Policy. 14 The Bidders Should Quote The Applicable Hsn Codes And It Is The Yes Yes Allowed Responsibility Of The Tenderer To Quote The Correct Hsn Code And Upload The ( Mandatory ) Document. 15 The Warranty Period Shall Be Two Years From The Date Of Issue Of Yes Yes Allowed Performance Certificate ( I.E., Jointcommissioning Note With Three Days ( Optional ) Prove Out Trial + 30 Days Performance Trial ) . During Warranty Period, Preventive Maintenance Shall Be Carried Out On Quarterly Basis, For This Separate Payment Will Not Be Given. The Details Of Preventive Maintenance To Be Provided During Warranty Period Shall Be Indicated By The Tenderer Giving Details Of Type Of Preventive Schedule, Periodicity On Items To Be Checked, Items To Be Replaced And Expected Plant Down Time. Preventive Maintenance Schedules Shall Be Conducted On Weekends As Far As Possible Or Any Other Day Through Mutual Agreement With Consignees. The Details Of Preventive Maintenance Services To Be Provided Under Warranty Shall Be Rovided By The Tenderer In The Following Format At 23.2 Of Technical Specification Attached. Page 5 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 16 It Is Certified That Our Firm Has Not Been De-Listed For Tendered Item By Indian Yes Yes Not Allowed Railways During Previous Three Years. 17 Please Submit The Details Of The Location At Which The Local Value Addition Is Yes Yes Not Allowed Being Made 18 Declaration On Cartel Formation The Definition Of Cartel Would Be As Per Yes Yes Allowed The Competition Act 2002 ( 12 Of 2003 ) . I / We Declare That I / We Are Not A ( Mandatory ) Part Of Cartel With Other Vendors And Have Offered Competitive Rates In The The Tenders. In The Event Of My / Our Offer Suspected To Be Of Collusive Bidding And Cartel Formation, I / We Understand That Purchaser Reserves The Right To Summarily Reject The Offer And To Ban My / Our Firm From Dealing With Railway. In The Event Of My / Our Offer Confirming To Any Aspect Of The Definition Of Cartel, I / We Understand That The Purchaser Reserves The Right To Refer The Matter To The Competition Commission Of India ( Cci ) Which Is A Statutory Body Constituted Under This Act, For Providing Necessary Relief To The Purchaser Who Represent Central Government Organization Serving The Public. In Addition, I / We Are Aware Of The Chapter Vi Of The Act, Which Deals With Penalties. I / We Understand That This Will Be In Addition To Other Rights And Remedies Available To The Railway Administration Under The Contract And The Law Of The Land. 19 Cartel Formation I / We Declare That I / We Are Not A Part Of Cartel With Yes Yes Allowed Other Vendors And Have Offered Competitive Rates In The Tenders. Please ( Mandatory ) Refer Clause 10.11.7 Of Section Ii Of Bid Document. 20 In Case Of Mse Firm Willing To Claim The Benefits Under Public Procurement Yes Yes Allowed Policy ( Preference To Mse ) Order 2012, The Firm Should Upload With Their ( Optional ) Offer, The Proof Of Their Being Mse Registered With Any Of The Agencies Mentioned In Clause 13.1 Of Section-I Of Icf Bid Document Failing Which Such Offers Will Not Be Liable For Consideration Of Benefits Detailed In Para 13.3 Of Section-I Of Icf Bid Document Tenderers Shall Upload Valid Documents As Per Mse Policy Showing That The Enterprise Is Owned By Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs To Claim The Benefit Under This Sub-Classification. For This Purpose Tenderers To Submit Details Of Share Holding Pattern & Controlling Stakes With Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs Duly Certified By Ca, Failing Which It Will Be Presumed That They Have No Claim Under This Sub-Classification. 21 1.Traders / Distributors / Sole Agent / Works Contract Are Not Exempted From Yes Yes Allowed Payment Of Emd As They Are Excluded From The Purview Of The Mse Policy ( Mandatory ) . 2. In Reference To Conditions No.6.1 ( Vi ) Of Section I Of Icf Bid Document, The Exemption Of Emd Is Applicable Only To The Vendors Having Current And Valid Registration With Pcmm Of Any Zonal Railways / Production Unit For Trade Groups 6579. Firm Should Submit Valid Registration Certificate For Proof. 22 Firm To Quote Strictly As Per Specification Attached. Please Go Through The Yes Yes Allowed Other Conditions Mentioned In The Tender With Regard To Arrangements ( Optional ) Before Supply And Erection. 23 The Tenderers Shall Indicate The Details Of Their Jurisdictional Assessing Yes Yes Allowed Officers ( Designation, Address & Email Id ) . ( Optional ) 24 Make In India: As Per Public Procurement ( Preference To Make In India ) Yes Yes Allowed Order 2017, As Amended, Only Class-I And Class-Ii Local Suppliers Are ( Mandatory ) Eligible To Participate In The Tender. Vendors Who Do Not Qualify To Be Class-I Or Class-Ii Local Suppliers Should Not Quote In The Tender As Their Offers Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class-I Or Class-Ii Local Suppliers For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Page 6 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 25 Scope Of Supply : 1. The Scope Of Supply Shall Include Design, Supply, Yes Yes Allowed Installation, Testing, Commissioning And Proving Out, Warranty Of ( Mandatory ) Electromagnetic Crack Detector Equipment On Turnkey Basis, Required For Crack Detection Of Various Types Of Axles As Per En 13261 As Listed In Annexure -E. The Supply Shall Include All The Concomitant Accessories / Equipments As Detailed In The Specification And Other Concomitant Accessories / Equipment, Which The Manufacturer Considers Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include Installation And Commissioning Of Related Equipment, Training Of Personnel In Operation And Maintenance Of Machine As Per Clause 10.1 And Supply Of Technical Documentation As Per Clause 11 Of Technical Literature. 2. The Scope Of Supply Includes Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For Using The Equipment. 26 Please Enter The Percentage Of Local Content In The Material Being Offered. No Yes Not Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Please Download And Peruse The Tender Document Conditions Applicable For No No Not Allowed Tenders Which Is Attached With The Tender. 2 Icf Bid Document Version 9 Dated 01.11.22 Is Applicable For This Tender. No No Not Allowed 3 Material To Be Supplied At Shell Depot No No Not Allowed Other Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tpi Agency, As Per The Clause 16.0 Of Technical Specification Attached. No No Not Allowed 2 Tenderer To Indicate The Address And Place Of Inspection For Tpi Inspection No No Not Allowed 3 The Tenderer Shall Have Capacity To Undertake Comprehensive Annual Yes Yes Allowed Maintenance Contract. ( Optional ) 4 Suitable Warranty Clauses, Bank Guarantee Clauses, Preventive Yes Yes Allowed Maintenance During Warranty, Penalty For Delay In Commissioning, Delay ( Optional ) During Maintenance Other Than The Above Mentioned Shall Be Applicable As Per The Guidelines Issued By General Conditions Of Contract ( Stores ) For M&P Items In Addition To The Warranty Clauses Mentioned Above Whichever Is Stricter. Special Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers May Note That The Ireps Software Is Contiunously Being No No Not Allowed Upgraded And The Forms May Be Subject To Changes. Tenderers Are Advised To Keep Themselves Updated With The Latest Changes, By Referring To The Latest Versions Of User Manuals Available On The Website, And By Taking Notes Of The Messages Sent By Our Ireps Adminstrator From Time To Time. Tenderers Should Also Make Themselves Fully Acquainted With All Available Templates / Forms Before They Submit Their Offer. No Claim Shall Be Entertained From A Tenderer, On Account Of Non Familarity With Any Of The Templates And Form Available On The Ireps Websites. Page 7 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 2 A ) No Manual Submission Of Documents Is Permitted. Tenderers Shall No No Not Allowed Upload All The Documents In Ireps Portal Only. 3 Tenederers Can Upload Individual File Having Capacity Of 3.5 To 3.7 Mb As No No Not Allowed Attached Document However There Is No Llimitation On The Numbers Of Files Which Can Attached. Tenderers Are Advised To Upload The Documents Well In Advance To Avoid Last Minutes Rush And Complication. All Documents Which Are Submitted Should Be In A4 Size To Facilitate Printing. 4 Tenderers To Refer The List Of Mandatory And Optional Certificates To Be No No Not Allowed Submitted Along With The Offer As Per Icf Bid Documents. 5 Please Check Ireps Website Before Submitting Offer, Any Corrigendum To No No Not Allowed The Tender Has Been Issued Or Not.Please Check Ireps Website Frequently For Corrigendum And Ensure Submission Of Offer As Per Corrigendum Issued By Icf 6 The Minimum Local Content For The Local Supplier Of The Tendered Item To Be No No Not Allowed Categorised As Class-I Local Supplier Shall Be 50% And Class-Ii Supplier Is 20% 7 Offers From Different Tenderers Submitted From The Same Ip Address In A No No Not Allowed Tender Shall Be Treated As Suspected Cartel And All Such Offers Received From The Same Ip Address Will Be Summarily Rejected. However Offers Resulting In Same Ip Address Due To Administrative Reason Like Technical / Networking Issue At Cris Server Shall Not Be Treated As Suspected Cartel And The Decision Of The Railway Administration Will Be Binding On All Tenderers 8 Firm To Submit The Clause Wise Compliance / Deviation Description And Past No No Not Allowed Performance Detail As Per The Annexure -A Attached. Technical-Compliances S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers Are Advised To Go Through All The Clauses Of This Document, Icf Yes Yes Allowed Bid Document And Other Documents Attached And Submit Necessary ( Optional ) Documents, Certificates, Attachments, Etc. Along With The Offer To Establish Their Credentials In Support Of Their Claim. If Required, Clarifications Will Be Sought Only On The Documents Submitted And No Additional Documents Shall Be Entertained Post Tender Opening. 2 Firm To Submit The Clause Wise Compliance For Yes Yes Allowed Technical Specification / Deviation Statement And Past ( Mandatory ) Performance Details As Per The Annexure - A Attached. 3 Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Yes Yes Allowed Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For ( Optional ) Using The Equipment. 4 Bidder Shall Train The Minimum Nominated 5 Railway Staff For Operating, Yes Yes Allowed Maintenance For Using The Equipment. ( Optional ) 5 Prove Out At Consignees Works : The Firm Shall Be Required To Demonstrate Yes Yes Allowed The Machine Capability & Prove Out The Various Performance Tests And ( Mandatory ) Claimed Productivity Requirement / Cycle Time On 20 Nos. Of Axles As Listed At Annexure-E At Consignees End For The Period Of Three Days Comprising 8 Hour Shift During Commissioning Of Machine. Undertakings S.No. Description Confirmation Remarks Documents Required Allowed Uploading Page 8 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 1 I / We Also Confirm That If Any Information And Document Submitted Is Found No No Not Allowed To Be False / Incorrect At Any Time, Icf May Cancel My / Our Bid And Action As Deemed Fit May Be Taken Against Me / Us, Including Termination Of The Contract, Forfeiture Of Earnest Money, Security Deposit And Banning / Delisting / Suspension Of Our Firm And All Partners Of The Firm. 2 I / We Also Confirm That Rates And Other Financial Terms Quoted In Relevant No No Not Allowed Columns Of Financial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Should Not Be Considered For Inter-Se Evaluation And Should Be Ignored. 3 I / We Have Gone Through The All Clauses Of This Tender Document And Other No No Not Allowed Documents Such As Icf Bid Document Version 05, Special Condition Of Tenders, Checklist And Technical Specification Uploaded Along With This Tender. It Is Understood That The Tenderer Submitting Their Offer Is Fully Aware Of All The Clauses Of The Above Said Documents And Undertake To Abide By Submitting This Offer. 6. Documents Attached With Tender S.No. Document Name Document Description 1 4235187.Pdf Technical Specification 2 4305772.Pdf Tpi Condition 3 4305380.Pdf Bid Document Ver-09, Dated 01 / 11 / 2022 7. Responsiveness S.No. Description Validity Of Offer: No Deviation From The Offer Validity Period Stipulated In The Nit Header Of This Tender Document Is 1 Permitted. For Additional Conditions Please Refer Clause 12.0 Of Section -I Of Icf Bid Document Version 09. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers ( Designation, Address & Email Id ) . In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy ( Make In India ) Order 2017, Dated 15 / 06 / 2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015 / Rs ( G ) / 779 / 5 Dated 03 / 08 / 2017 And 27 / 12 / 2017 And Amendments / Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm / Dc ( V.N. Satheesan ) , Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf , Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf , Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers
Contract Date: May 07, 2026 Contract Value : 35.16 Lakh
Government Departments No of Bidders 1
26.
Public Administrative Department #10978093 AOC
Tender For Provision Of Cctv Surveillance System In M&Cw Center (Ayushman Arogya Mandir) Mandawaliin Ward No.200 Under Shahdara (South) Zone.; 1 SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL N 2 SITC of 4MP fixed lens Dome IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL 3 SITC of 16 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :160Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of 8TB surveillance HDD 5 SITC of full HD LED Monitor,32 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at site with connectionsand along with all accessories etc. Complete as required. 6 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 7 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required(a)25 mm 8 CABLING WIRING, Supplying and laying of 2x1.5 sq mm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 9 SITCIP65 box(without PoE switches)of dimention 310mmX160mmX140 mm onpole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set 10 SITC of 16 port Giga PoE switch, 16(PoE 10/100) + 2(10/100/1000) + 1G SFP Slot long distance switch 11 S&F of suitable size GI boxwith modular plate and coverin front on surface or in recess , includingproviding and fixing 6 pin 5/6 & 15/16 amps modular Socket outlet and 15/16 amps modular switch, connectionetc. as reqd 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 13 Online UPS - Input supply: Single Phase, Output Supply :SinglePhaseSupplying, installation, Testing & Commissioning of following capacity at full load(Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shallinclude a Rectifier, inverter, battery bank suitable for 30 minutes back up(Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container)and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall beMicroprocessor based Digital Control,using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturingand inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.The operating efficiency of the UPS systems shall be >95% at 100%non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input gridshall be< 5% at 100 %load. (The required LCfilters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall besuitable for incoming supplyAC single phase 160-270V 50 Hzand delivering output ACsupply true sine wavesingle phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.. Operating temperature0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Displayfor watt/VA,Amp and Voltage power parametersetc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2,it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be withIGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductorcable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPSshould have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 3KVA 14 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U 15 Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
Contract Date: May 06, 2026 Contract Value : 2.19 Lakh
Local Bodies No of Bidders 4
27.
Power #10912971 AOC
Bids Are Invited For Preventive Maintenance & Load Testing/ Inspection Of Material Handling Equipments (E.G. Hoists, Eot Cranes, Mobile Cranes & Forklifts Etc.) And Maintenance Of Rolling Shutters.; 1.0 PM of Cranes & Hoists 1.01 Six Monthly preventive maintenance of EOT Crane (capacity 2 ton to 75 ton) / Electric hoist (0.5T to 12.5T) as per the approved checklist 200.0 Nos. 1.02 Annual preventive maintenance of EOT Crane (capacity 2 ton to 75 ton)/Electric hoist (0.5T to 5T) as per the approved checklist 100.0 Nos. 2.0 Load testing of Crane & Hoist, Chain pulley block, mobile crane, forklift, max puller 2.01 Annual load testing of EOT crane (Capacity 2 ton to 20 ton). 40.0 Nos. 2.02 Annual load testing of EOT crane (Capacity 30 ton to 75 ton) 10.0 Nos. 2.03 Annual load testing of Electric hoist (Capacity 0.5 to 12.5 Ton). 50.0 Nos. 2.04 Annual load testing of mobile cranes & DPT of hook (Capacity 55 ton & 12 ton) 2.0 Nos. 2.05 Annual load testing of forklifts (Cap 1 ton to 10 ton) 8.0 Nos. 2.06 Annual PM & load testing of manual hoist ( mono rail with chain pulley block) capacity 0.5 ton to 5 ton 180.0 Nos. 2.07 Annual PM & load testing of Chain Pulley block (SWL0.5 ton to 5 tonn) 185.0 Nos. 2.08 Annual PM & load testing of Hydraullic Pellet Trolley (SWL:upto 3 Tonn) 70.0 Nos. 3.0 Inspection of Specila liftin tool tackles, D-shackle,eyebolt and special lifting tackles 3.01 Dismantling, visual & DPT, boxup of HP turbine rotor lifting beam 2.0 Nos. 3.02 Dismantling, visual & DPT, boxup of LP turbine rotor lifting beam 2.0 Nos. 3.03 Dismantling, visual & DPT, boxup of Turbine easing gear 2.0 Nos. 3.04 Dismantling, visual & DPT, boxup of LP turbine outer casing lifting pin 8.0 Nos. 3.05 Dismantling, visual & DPT, boxup of Turn buckle for lifting HP turbine casing 2.0 Nos. 3.06 Dismantling, visual & DPT, boxup of PCP lifting pin-plate assembly consisting of 4 nos. of plates and 6 nos. of pins. 2.0 Nos. 3.07 Dismantling, visual & DPT, boxup of chlorine toner lifting beam (attached to manual hoist Nos. 0-76230-MH-07 of 2T capacity) consisting of 1 no. of plate and 4 nos. of pins/bolts, 1 No. of D shackles, 3 nos. of hook. 2.0 Nos. 3.08 Annual inspection of slings, D-shackles & eye bolts. 1900.0 Nos. 4.0 Maintenance of rolling shutter 4.01 Six Monthly preventive maintenance of turbine building motor operated rolling shutter (size max. 5mx12m). 20.0 Nos. 4.02 Complete Overhauling of Rolling of shutter (Size Max. L-6 Mtr x H-7Mtr, 5Mx12M) 25.0 Nos. 5.0 Need based maintenance of EOT cranes, hoists and Shutter 5.01 Wire rope replacement of EOT crane/ electric hoists (if required) 2.0 Nos. 5.02 Overhauling of LT gearbox /CT gearbox/ Main hoist gearbox of EOT crane/ electric hoist having SWL up to 75 Ton (if required) 3.0 Nos. 5.03 Maint. / replacement of thruster /electromagnetic brake of crane & hoist (if required ) 15.0 Nos. 5.04 Revamping /redressing of control panels of crane & hoist, if required 8.0 Nos. 5.05 Replacement of pendant/its set of button for EOT Crane/Hoist 8.0 Nos. 5.06 Replacement / maintenance of limit switch/fuse of crane & hoist, cleaning of contacts, moisture etc if required 65.0 Nos. 5.07 Maintenance/ replacement of wheel (each) of crane& hoist 6.0 Nos. 5.08 Laying of power cable having outer dia meter 6 mm to 80 mm in existing cable trays. 300.0 Nos. 5.09 Removal & shifting of manual hoist/CPB from one location and its installation at another location. 22.0 Nos. 5.1 Motor overhauling of motor From 0.18 KW to 3.7 KW, as per applicable procedure . 5.0 Nos. 5.11 Motor overhauling of motor From 5.5 KW to 22.5 KW, as per applicable procedure 4.0 Nos. 5.12 Motor overhauling of motor From 30.0KW to 75.0 KW, as per applicable procedure . 2.0 Nos. 5.13 Decoupling of Motor and Gear Box,allignment correction and coupling. 4.0 Nos. 5.14 Removal and Fixing of coil spring of matching size and shape of shutter. 20.0 Nos. 5.15 Removal and Fixing of lower/upper gear assembly of shutter 10.0 Nos. 5.16 Removal and Fixing of shutter iron strips as per matching size. 50.0 Nos. 5.17 Replacement of shutter rotor cover of matching size. 6.0 Nos. 5.18 Repair of shutter rotor and coil spring 20.0 Nos. 5.19 Rewinding of Electromagnetic (EM) brake coil of crane . 20.0 Nos. 6.0 Maintenance coverage and Crane operation 6.01 Maintenance coverage for attending complaint of crane/hoist upto 8 hrs during normal working day. 130.0 Nos. 6.02 Maintenance coverage for attending complaint of crane/hoist or coverage during lifting of any critical load upto 4 hrs during off hrs or holiday. 200.0 Nos. 6.03 EOT Crane/Electric Hoist operation upto 8 hrs during normal hours on any working day. 600.0 Nos. 6.04 EOT Crane/Electric Hoist operation upto 4 hrs during off hours, Sunday, Holiday 360.0 Nos. 7.0 Supply Items 7.01 Supply of new brake coil of Electro magnetic (EM) brake for different cranes. 12 Nos. 7.02 Supply of strip /spring for shutters (Kg) 150 Kg 7.03 Supply of Electro hydraulic Thrust brake suitable for 300 mm to 400mm drum dia with 18 kg load to work on 3 phase 50C/s,400/440 volts, braking torque 42 Kg.M without drum 7 Nos. 7.04 Supply of Electro hydraulic Thrust brake suitable for 100 mm to 200 mm drum dia with 18 kg load to work on 3 phase 50C/s,400/440 volts,braking torque 42 Kg.M without drum 7 Nos. 7.05 Supply of Chain Pulley Block, SWL-1 Ton, Lift -10 Mtrs 2 Nos. 7.06 Supply of Chain Pulley Block, SWL-2 Ton, Lift -10 Mtrs 2 Nos. 7.07 Supply of Chain Pulley Block, SWL-3 Ton, Lift -10 Mtrs 2 Nos. 7.08 Supply of Chain Pulley Block, SWL-5 Ton, Lift -10 Mtrs 1 Nos. 7.09 Manual Hoist Trolley with Chain Pulley Block each having SWL:5.0 Tonn with length of chain upto 10 Meter 2 Nos.
Contract Date: Ref. Documents Contract Value : 72.35 Lakh
Boards / Undertakings / PSU No of Bidders 6
Uttar Pradesh View Result →
28.
Railways #10910841 AOC
Supply Of Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp)Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp),Set Of Items - (1) Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bor E Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp), With Ip65- Rated Enclosure, Corrosion-Resistant Wetted Parts Compatible With Treated Effluents, I Ntegral Or Remote Digital Display, 4-20 Ma And Pulse Output, Modbus/Rs485 Communication, Dual Power Su Pply (220V Ac, 50 Hz/ Optional 24 Vdc), And Temperature Range 20 Degree C To 180 Degree C, Including Calibration And Configuration, Complete As Per Manufactures Specification And Direction Of Engineer-In-Cha Rge (Make: Aster/Upc Or Equivalent Approved, Model - Mag - Flow 650 Or Similar) - Qty. - 01 No. (2) Compl Ete Pvc Piping System With 3-Valve Bypass Arrangement, Comprising Two Pvc Ball Valves For Isolation, One Pvc Ball Valve For Bypass, And One Pvc Flow Control Valve, All Connected Through A High-Quality Pvc Header Of Suitable Diameter; Including All Associated Fittings Such As Tees, Crosses, Elbows, Reducers, Sockets, Plugs , Unions, Supports, Clamps, Hangers, Fasteners, And Anchoring Accessories; With Cutting, Chasing, And Restor Ation Of Walls/Floors To Original Condition Where Necessary; Scope Also Includes Supply And Installation Of Ele Ctrical Starter (As Per Equipment Rating), Along With Required Control Cabling, Terminations, And Interfacing, All Executed As Per Ga Drawing Approved By Rly. Authority., Qty. - 01 Lot. Detail Technical Specification As P Er Annexure Attached. [ Warranty Period: 30 Months After The Date Of Delivery ] ]
Contract Date: Apr 30, 2026 Contract Value : 1.26 Lakh
Government Departments No of Bidders 1
29.
Educational and Research Institute #10910485 Technical Bid
Tender For Supply, Installation, Testing And Commissioning Of Public Address System At Kuttambalam, Kerala Kalamandalam , Supply, Installation, Testing And Commissioning Of Public Address System At Kuttambalam, Kerala Kalamandalam (Before Quoting The Rate, The Bidder Shall Carefully Read The Conditions In The Nit And The Accompanying Special Conditions.) The Rates Quoted Are All-Inclusive And Include A Comprehensive Annual Maintenance Contract For One Year After The Oem Warranty Period Of Two Years.) The Reference Make And Model Mentioned Are Provided Solely To Indicate The Required Technical Specifications And Performance Standards Of The Item To Be Supplied. Bidders May Offer Any Approved Make, Provided That Such Products Fully Comply With Or Exceed The Specified Technical Parameters And Quality Requirements. , Powered Line-Array Loudspeaker Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Compact Two-Way Self-Powered Line-Array Loudspeaker Module Suitable For Live Sound Reinforcement, Auditorium, Touring, And Fixed Installation Applications, Incorporating Dual Low-Frequency Neodymium Transducers Of Approximately 6-7 Inches Each And A High-Frequency Compression Driver With Waveguide, Driven By Integrated Class-D Amplification With Built-In Dsp Processing For Crossover, Equalization, Delay, Limiting, And System Protection. The Loudspeaker Shall Deliver Continuous Power Handling In The Range Of Approximately 500-800 W Or Higher, Maximum Sound Pressure Level Of Not Less Than 130 Db Spl, Usable Frequency Response Extending Approximately From 60 Hz To 17 Khz Or Wider, And Horizontal Coverage Of About 100°-120°, Suitable For Scalable Vertical Array Deployment. The Enclosure Shall Be Of Rugged, Tour-Grade Construction With Integrated Rigging Hardware Enabling Safe Suspension Or Ground-Stacked Line-Array Configuration, And Shall Include Balanced Audio Input/Output Connectivity, Network Or Software-Based Control/Monitoring Capability Where Applicable, Power Cabling, Flying Accessories, And All Necessary Mounting Hardware Required For Complete System Deployment. The System Shall Be Fully Compatible With Professional Subwoofer Systems And Digital Audio Infrastructure, And Shall Be Supplied Complete With All Accessories, Interconnections, Documentation, Installation, Alignment, Testing, And Commissioning, Ensuring Uniform Coverage, Phase Coherence, Safe Rigging Compliance, And Noise-Free Operation In Accordance With Approved Technical Standards And Site Requirements. Reference Make & Model: Jbl Srx 906La Jbl Professional / Rcf / Db Technologies / Qsc / Wharfedale Pro , High-Power Powered Subwoofer Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Self-Powered Low-Frequency Subwoofer System Suitable For Live Sound Reinforcement, Auditorium, Touring And Fixed Installation Applications, Incorporating A Minimum Single 18-Inch High-Excursion Low-Frequency Transducer Housed In An Acoustically Optimized Enclosure And Driven By Integrated High-Efficiency Class-D Amplification With Built-In Dsp Processing For Crossover, Equalization, Delay, Polarity Control, Limiting, And Comprehensive System Protection. The Unit Shall Deliver Continuous Amplifier Power Of Not Less Than Approximately 1000 W Rms (Or Higher), Maximum Peak Sound Pressure Level Of Not Less Than About 130 Db Special And Usable Low-Frequency Response Extending To Approximately 35 Hz Or Lower, Suitable For Integration With Professional Full-Range And Line-Array Loudspeaker Systems. The Enclosure Shall Be Of Rugged Tour-Grade Construction With Durable Finish, Integrated Handles, Pole-Mount Provision For Satellite Loudspeakers, And Provision For Safe Ground-Stacking Or Transport, And Shall Include Balanced Audio Input And High-Pass Filtered Output Connectivity, Selectable Presets Or Network/Software-Based Control And Monitoring Where Applicable, Power Cabling, And All Necessary Mounting And Interconnection Accessories Required For Complete Deployment. The System Shall Be Supplied Complete With All Accessories, Interconnections, Documentation, Installation, Alignment, Testing, And Commissioning, Ensuring Proper Phase Integration, Uniform Low-Frequency Coverage, Safe Electrical And Mechanical Operation, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Fully Operational High-Power Subwoofer Solution. Reference Make & Model Jbl Srx 918S Approved Makes: Jbl Professional / Qsc / Rcf / Db Technologies / Wharfedale Pro , Compact Array Flying Frame For Powered Line-Array Loudspeaker Supply, Installation, Testing And Commissioning (Sitc) Of A Certified Compact Array Flying Frame Compatible With The Offered Professional Line-Array Loudspeaker System, Suitable For Suspension Or Ground-Stack Deployment In Live Sound, Auditorium, Touring, And Fixed Installations. The Frame Shall Feature A Two-Part Collapsible Or Modular Quick-Deployment Design, Constructed From High-Strength Corrosion-Resistant Metal, And Shall Be Rated To Safely Support The Complete Loudspeaker Array With Appropriate Safety Factor In Compliance With Relevant Rigging And Safety Standards. It Shall Include Secure Locking Mechanisms, Adjustable Tilt/Angle Provision, Certified Suspension Points, And Compatibility With Standard Lifting Hardware, And Be Supplied Complete With All Necessary Rigging Accessories, Fasteners, Safety Pins, Load-Rated Fittings, And Transport Provisions. Preferred Make & Model: Jbl Eon 710 Approved Makes: Jbl Professional / Yamaha / Qsc / Rcf / Db Technologies / Mackie / Ld Systems , Self-Powered Two-Way Floor Monitor Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Self-Powered Two-Way Floor Monitor Suitable For Live Sound Reinforcement, Stage Monitoring, Auditorium, And Installed Sound Applications, Incorporating A Custom-Designed 10-Inch Low-Frequency Transducer And A High-Frequency Compression Driver With Waveguide, Driven By Integrated High-Efficiency Class-D Amplification Delivering Not Less Than 1300 W Peak And 650 W Continuous Power, With Maximum Sound Pressure Level Of Approximately 125 Db Or Higher And Usable Frequency Response Extending Approximately From 52 Hz To 20 Khz. The Unit Shall Include A Built-In Multi-Channel Digital Mixer, Advanced Digital Signal Processing Derived From Professional Audio Processing Platforms Providing Equalization, Delay, Crossover, Feedback Control, And Protection Functions, Along With Balanced Xlr/Trs Combo Inputs, Bluetooth Or Equivalent Wireless Audio/Control Capability, And Balanced Xlr Link/Thru Output. Input Impedance, Gain Range, And Crossover Characteristics Shall Be Suitable For Professional Microphone- And Line-Level Operation. The Enclosure Shall Be Of Rugged, Acoustically Optimized Construction Suitable For Wedge-Monitor Or Pole-Mounted Deployment, Incorporating Integral Handles, Stable Base Geometry, And Durable Finish For Continuous Professional Use. The System Shall Be Supplied Complete With All Required Accessories, Interconnections, Documentation, Installation, Testing, And Commissioning, Ensuring Noise-Free Operation, Safe Electrical Performance, And Full Functional Compliance In Accordance With Approved Technical Standards And Site Requirements, Forming A Complete Deployable Powered Floor-Monitor Solution. Reference Make & Model: Jbl Eon 710 Approved Makes: Jbl Professional / Yamaha / Qsc / Rcf / Db Technologies / Mackie / Ld Systems , Supply, Installation, Testing And Commissioning Of: A 24-Channel Analog Mixing Console. A Professional Multi-Channel Analog Mixing Console Suitable For Live Sound Reinforcement And Auditorium Applications, Comprising A Minimum Of 16 Mono Microphone Input Channels With High-Quality, Low-Noise Mic Preamplifiers And +48 V Phantom Power, Along With Additional Stereo Input Channels, Together Forming A 24-Channel Analog Mixing Console, Balanced Xlr/Trs Connectivity, 3-Band Equalization With Sweepable Mid-Frequency And High-Pass Filter On Mono Channels, Equalization On Stereo Channels, Multiple Auxiliary Sends For Monitor And Effects Operation, Built-In 24-Bit Digital Signal Processor Providing Selectable Reverberation, Delay, And Modulation Effects, Subgroup And Main Stereo Bus Routing, Stereo Usb Or Equivalent Interface For Playback And Recording, Led Level Metering, Headphone And Control-Room Monitoring Outputs, Graphic Equalization On Main Outputs, Rugged Metal Chassis Suitable For Continuous Professional Use, And Complete With All Required Accessories, Interconnections, Power Supply, Documentation, Installation, Testing, And Commissioning In Accordance With Approved Technical Standards And Site Requirements. 24-Channel Analog Mixing Console Reference Make & Model: Soundcraft Nano M24 Approved Makes: Sound Craft / Yamaha / Allen & Heath / Mackie / Behringer. , Dynamic Vocal Microphone Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Wired Dynamic Vocal Microphone Suitable For Live Sound Reinforcement, Stage Performance, Public Address, And Studio Applications, Featuring A Moving-Coil Dynamic Transducer, Cardioid Polar Pickup Pattern For Effective Rear-Noise Rejection And Feedback Control, And Frequency Response Approximately 50 Hz To 15 Khz Optimized For Vocal Clarity. The Microphone Shall Incorporate A Durable All-Metal Body Construction, Integral Pneumatic Or Equivalent Shock-Mount System To Minimize Handling Noise, And Balanced Low-Impedance Xlr Output Compatible With Standard Professional Audio Mixing Consoles And Pa Systems. The Unit Shall Be Supplied Complete With Microphone Clip/Holder, Thread Adapter, Protective Storage Pouch Or Case, And Necessary Interconnection Accessories, And Shall Be Installed, Tested, And Commissioned To Ensure Noise-Free Performance, Proper Signal Integrity, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Vocal-Microphone Solution Suitable For Continuous Professional Use. Reference Make & Model Shure Sm 58 Approved Makes: Shure / Sennheiser / Akg / Audix , Dynamic Instrument Microphone Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Wired Dynamic Instrument Microphone Suitable For Live Sound Reinforcement, Studio Recording, Public Address And Installed Audio Applications, Incorporating A Moving-Coil Dynamic Transducer, Cardioid Polar Pickup Pattern For Effective Off-Axis Noise Rejection And Feedback Control, And Frequency Response Approximately 40 Hz To 15 Khz Optimized For Close-Miking Of Musical Instruments, Percussion, And Amplified Sound Sources. The Microphone Shall Feature A Rugged All-Metal Body Construction, Integral Pneumatic Or Equivalent Internal Shock-Mount System To Minimize Handling Noise And Vibration, And Balanced Low-Impedance Xlr Output Compatible With Standard Professional Mixing Consoles And Pa Systems Without The Need For External Power. The Unit Shall Be Supplied Protective Storage Pouch Or Case And Necessary Interconnection Accessories, And Shall Be Installed, Tested, And Commissioned To Ensure Noise-Free Performance, Proper Signal Integrity, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Instrument-Microphone Solution Suitable For Continuous Professional Use. Reference Make & Model Shure Sm 57 Approved Makes: Shure / Sennheiser / Akg / Audix , Professional Drum Microphone Package Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Complete Drum Microphone Package Suitable For Live Sound Reinforcement, Studio Recording, And Installed Performance Applications, Comprising Not Less Than Seven Wired Microphones Including One Dedicated Low-Frequency Kick-Drum Dynamic Microphone, Multiple Dynamic Microphones For Snare And Tom Applications, And A Pair Of Condenser Overhead Microphones Of Identical Make And Model Requiring Standard 48 V Phantom Power, All Featuring Cardioid Pickup Pattern, High Sound-Pressure-Level Handling Capability, Balanced Xlr Output Connectivity, And Frequency Response Optimized For Percussion Instruments. The System Shall Be Supplied Complete With Drum-Rim Mounting Hardware, Microphone Clips, Appropriate Interconnection Cables Where Applicable, And A Durable Protective Carrying Case, Forming A Fully Deployable Drum-Miking Solution Compatible With Standard Professional Audio Mixing Consoles And Pa Systems. The Equipment Shall Be Of Robust Construction Suitable For Continuous Professional Use And Shall Include All Accessories, Interconnections, Documentation, Installation, Testing, And Commissioning In Accordance With Approved Technical Standards And Site Requirements. Reference Make & Model: Shure Pga Drumkit 7 Shure / Sennheiser / Akg / Audix , Compact Overhead Condenser Microphone Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Compact Overhead Condenser Microphone System Suitable For Speech Reinforcement, Choir Capture, Conferencing, And Installed Sound Applications, Comprising A Miniature Condenser Microphone Capsule With Flexible Gooseneck Or Suspension Provision And Interchangeable Polar Pattern Cartridges (Minimum Omnidirectional And Cardioid) To Enable Adaptable Coverage. The Microphone Shall Provide Wide And Natural Frequency Response Approximately 50 Hz To 17 Khz, High Dynamic Range (˜ 95 Db Or Greater), Minimum Common-Mode Rejection Of About 45 Db, And Balanced Low-Impedance Output With Defined Polarity, Ensuring Clear And Accurate Sound Reproduction With Low Noise And Distortion. The Unit Shall Operate On Standard Phantom Power In The Range Of Approximately 11 V To 52 V Dc With Low Current Consumption, And Shall Include An In-Line Or Integrated Preamplifier With Controlled Clipping Characteristics Suitable For Professional Audio Systems. The System Shall Be Supplied Complete With Suspension Accessories, Interchangeable Cartridges, Necessary Interconnection Components, Documentation, Installation, Testing And Commissioning, Ensuring Stable Overhead Deployment, Noise-Free Performance, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Fully Deployable Overhead Condenser Microphone Solution Suitable For Continuous Installed Use. Reference Make & Model : Shure Mx202 Shure / Audio-Technica / Akg / Electro-Voice / Earthworks / Samson / Peavey , 12-Inch Powered Two-Way Loudspeaker With Tripod Stand Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Self-Powered Two-Way Full-Range Loudspeaker Suitable For Live Sound Reinforcement, Stage Monitoring, Auditorium, And Installed Sound Applications, Incorporating A Custom-Designed 12-Inch Low-Frequency Transducer And A High-Frequency Compression Driver With Waveguide, Driven By Integrated High-Efficiency Class-D Bi-Amplification Delivering Not Less Than 1300 W Peak And 650 W Continuous Power, With Maximum Peak Sound Pressure Level Of Approximately 127 Db Or Higher And Usable Frequency Response Extending Approximately From 50 Hz To 20 Khz. The Loudspeaker Shall Provide Nominal Dispersion Coverage Of About 100° (H) × 60° (V), Balanced Xlr/Trs Combo Audio Inputs With Xlr Link/Thru Output, And Integrated Advanced Digital Signal Processing Including Equalization, Delay, Feedback Suppression, Ducking, And Protection Functions, Together With A Built-In Multi-Channel Digital Mixer, Bluetooth Or Equivalent Wireless Audio/Control Capability, And User-Interface Display For System Configuration. The Enclosure Shall Be Of Rugged, Acoustically Optimized Portable Construction With Integral Handles, Pole-Mount Provision, And Durable Finish Suitable For Continuous Professional Deployment. The System Shall Be Supplied Complete With A Heavy-Duty Adjustable Tripod Speaker Stand Compatible With The Loudspeaker Pole Socket, Incorporating Stable Base Design, Height-Locking Mechanism, And Adequate Load-Bearing Capacity For Safe Operation, Along With All Necessary Accessories, Interconnections, Documentation, Installation, Testing, And Commissioning, Ensuring Noise-Free Operation, Safe Mechanical And Electrical Performance, And Full Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Powered Loudspeaker Solution. Reference Make & Model Jbl Eon 712 Jbl Professional / Qsc / Rcf / Yamaha , Compact 12-Channel Analog Audio Mixing Console Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Compact Multi-Channel Analog Audio Mixing Console Suitable For Live Sound Reinforcement, Studio Recording, Public Address, And Installed Sound Applications, Comprising Not Less Than 12 Input Channels Including A Minimum Of 8 Mono Microphone/Line Input Channels With High-Quality Low-Noise Mic Preamplifiers And +48 V Phantom Power, Together With Additional Stereo Input Channels, Balanced Xlr/Trs Connectivity And Channel Equalization Suitable For Professional Audio Mixing. The Mixer Shall Incorporate Built-In Digital Signal Processing And/Or Effects Processing, Integrated Stereo Usb Audio Interface For Recording And Playback With Computer Connectivity, Usb Media Playback/Recording Capability, And Bluetooth Or Equivalent Wireless Audio Input, Along With Auxiliary Send(S), Main Stereo Outputs With Level Metering, And Headphone/Control-Room Monitoring Facilities. The Unit Shall Feature A Rugged Compact Chassis Suitable For Continuous Professional Use, And Shall Be Supplied Complete With All Required Accessories, Interconnections, Power Supply, Documentation, Installation, Testing, And Commissioning, Ensuring Noise-Free Performance, Reliable Operation, And Full Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Compact Mixing Solution Suitable For Stage, Studio, And Installed Environments. Reference Make & Model: Soundcraft Nano M12bt Soundcraft / Yamaha / Behringer / Mackie / Allen & Heath , 24-Channel Rack-Mountable Remote-Controlled Digital Mixer With Usb Multitrack Recording Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Rack-Mountable Digital Audio Mixing Console With Integrated Usb Multitrack Recording Capability, Suitable For Live Sound Reinforcement, Studio Production, Broadcast, And Installed Sound Applications, Comprising Not Less Than 24 Input Channels With High-Quality Microphone Preamplifiers, Balanced Analog And Digital Input Connectivity, And Fully Recallable Digital Signal Processing On All Channels. The System Shall Provide Remote-Control Capability Via Built-In Dual-Band Wi-Fi And/Or Ethernet, Enabling Operation From Multiple Standard Web-Browser-Enabled Devices Across Major Operating Systems Without Dedicated Software, And Shall Support Simultaneous Control From Multiple Devices For Flexible Mixing And Monitoring. The Mixer Shall Incorporate Integrated Professional Signal Processing Including Equalization, Dynamics Control, Feedback Suppression, Delay, And Effects Derived From Established Audio-Processing Platforms, Along With Multitrack Recording Of Input Channels And Stereo Mix Directly To Usb Storage And/Or A Connected Computer, Forming A Complete Recording And Mixing Solution. The Unit Shall Be Housed In A Road-Rugged Rack-Mountable Enclosure Suitable For Stagebox Or Fixed-Installation Deployment, And Shall Provide Multiple Auxiliary Outputs, Main Outputs, Headphone Monitoring, And Computer Audio-Interface Functionality. The Scope Shall Include The Supply Of The Latest Compatible Software/Firmware Version And An Appropriate Control Interface Device (Tablet) Required For Proper Configuration, Remote Operation, And Monitoring Of The System. The Supply Shall Further Include All Necessary Accessories, Interconnections, Documentation, Installation, Testing, And Commissioning, Ensuring Reliable Operation, Noise-Free Performance, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Digital Mixing And Recording System. Reference Make & Model: Soundcraft Ui24r Soundcraft / Allen & Heath / Behringer / Yamaha Tablet: Fully Compatible With The Supplied Mixer For Seamless Operation And Control. , Supply, Installation, Testing And Commissioning Of Signal Cable & Interconnectors As Per Requirements. Approved Make Cable: Belden / Canare / Mogami / Amphenol Approved Interconnectors Neutrik,Canare, Belden, Switchcraft, Amphenol, Seetronic, Rean, Hicon, Deltron , 8-Channel Stage Snake Cable With Stage Box Supply, Installation, Testing And Commissioning (Sitc) Of A Professional 8-Channel Audio Multicore (Snake) Cable Assembly With Stage Box, Suitable For Live Sound Reinforcement, Auditorium, Studio, And Installed Pa System Applications. The System Shall Comprise Not Less Than Eight Balanced Low-Noise Microphone/Line Channels Constructed Using High-Purity Copper Conductors With Individually Shielded Twisted Pairs And Overall Protective Shielding, Enclosed In A Flexible, Abrasion-Resistant Outer Jacket Designed For Stage And Fixed-Installation Environments To Ensure Minimal Signal Loss, Low Electromagnetic Interference, And Reliable Long-Term Performance. The Stage End Shall Terminate In A Rugged Metal Stage Box Fitted With Clearly Numbered Professional Xlr Female Input Connectors (Minimum 8 Channels) And Appropriate Strain Relief, While The Console End Shall Provide Matching Xlr Male Fan-Out Connectors Or Multipin Termination Of Suitable Length For Mixer Connectivity. All Connectors Shall Be Professional-Grade With Secure Contact, Proper Grounding, And Mechanical Protection To Maintain Consistent Signal Integrity. The Multicore Assembly Shall Be Of Suitable Length As Required At Site, Properly Laid, Dressed, Labeled, And Tested For Continuity, Insulation Resistance, Shielding Effectiveness, And Noise-Free Operation. The Supply, Installation, Testing And Commissioning Scope Shall Include All Terminations, Routing Accessories, Identification Ferrules, Documentation, Testing, And Commissioning, Forming A Complete And Fully Operational Stage-To-Mixer Signal Interconnection System In Accordance With Approved Technical Specifications And Site Requirements. Approved Make: Belden / Neutrik / Canare / Mogami / Amphenol , 27U Equipment Rack With Power Distribution Unit Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Standard 27U Equipment Rack Enclosure Suitable For Housing Audio, Networking And Control Equipment Associated With The Pa And Av System. The Rack Shall Be Of Robust Steel Construction With Corrosion-Resistant Powder-Coated Finish, Providing Adequate Load-Bearing Capacity, Ventilation Provisions, Cable-Management Access, And Secure Front Door With Locking Arrangement, Along With Removable Side Panels And Appropriate Mounting Rails Conforming To International Rack Standards. The Rack Shall Be Supplied Complete With A Rack-Mountable Power Distribution Unit Providing Multiple Switched And Fused Ac Output Sockets, Proper Earthing/Grounding Arrangement, Overload Protection, And Suitable Input Power Cord, Ensuring Safe And Reliable Power Distribution To All Installed Equipment. The Installation Shall Include All Necessary Mounting Hardware, Blanking Panels, Cable Organizers, Labeling, Earthing Connections, And Internal Power Wiring, And The System Shall Be Properly Assembled, Installed, Tested, And Commissioned To Ensure Mechanical Stability, Electrical Safety, Effective Heat Dissipation, And Reliable Operation In Accordance With Approved Technical Standards And Site Requirements, Forming A Complete And Ready-To-Use Equipment Rack Solution. Approved Makes: Valrack / Netrack / Rittal / Or Equivalent Professional-Grade Manufacturers Meeting Or Exceeding The Specified Technical Parameters. , Microphone Mini Boom Stand Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Microphone Mini Boom Stand Suitable For Stage Performance, Studio Recording, Auditorium, And Installed Sound Applications. The Stand Shall Be Of Robust Metal Construction With Corrosion-Resistant Finish, Incorporating A Stable Weighted Base Or Tripod Base, Height-Adjustable Vertical Shaft, And A Compact Adjustable Boom Arm With Secure Locking Mechanism For Precise Microphone Positioning. The Stand Shall Provide Standard Microphone Mounting Thread Compatibility (3/8? And 5/8? With Suitable Adapter) And Shall Be Capable Of Supporting Typical Dynamic Or Condenser Microphones Without Vibration Or Drift, Ensuring Stable And Noise-Free Operation During Use. The Unit Shall Be Supplied Complete With All Necessary Mounting Accessories, Thread Adapters, Tightening Knobs, And Protective Fittings, And Shall Be Installed, Tested, And Commissioned To Ensure Mechanical Stability, Smooth Adjustment, And Reliable Performance In Accordance With Approved Technical Standards And Site Requirements, Forming A Complete Deployable Microphone Stand Solution Suitable For Continuous Professional Use. Approved Makes : Hercules / K&M / On-Stage / Gator / Samson / Ultimate , Supply, Installation, Testing And Commissioning Of Microphone Boom Stand Having Technical Specifation As Item No: 1.16 Approved Makes : Hercules / K&M / On-Stage / Gator / Samson / Ultimate , 16A + 6A Combo Power Distribution Unit (8-Socket) Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Rack-Mountable Or Portable Power Distribution Unit (Pdu) Suitable For Audio-Visual, Pa, And Equipment Rack Applications, Providing A Minimum Of Eight Ac Output Sockets In A 16A + 6A Combination Configuration Compatible With Standard Indian Electrical Systems. The Unit Shall Be Of Robust Metal Construction With Fire-Retardant Insulated Components, Incorporating Individual Or Grouped Switched Outputs, Suitable Internal Wiring, Proper Earthing/Grounding Provision, And Protection Features Such As Overload Protection, Fuse Or Mcb Safeguarding, And Surge Suppression Where Applicable, Ensuring Safe And Reliable Power Delivery To Connected Equipment. The Pdu Shall Be Designed For Continuous Professional Use, With Clearly Labeled Sockets, Secure Input Power Connection Of Appropriate Current Rating, And Compatibility With Standard Rack Or Equipment Mounting Arrangements. Approved Makes : Valrack / Netrack / Rittal / Hager / Legrand / Or Equivalent Professional-Grade Manufacturers Meeting Or Exceeding The Specified Technical Parameters. , Wireless Handheld Vocal Microphone System Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Wireless Handheld Vocal Microphone System Suitable For Live Sound Reinforcement, Stage Performance, Auditorium And Installed Pa Applications, Comprising A Dynamic Handheld Microphone Capsule With Cardioid Polar Pickup Pattern And Frequency Response Approximately 50 Hz To 15 Khz Optimized For Clear Vocal Reproduction And Effective Feedback Rejection. The System Shall Include A Uhf Or Equivalent Professional Wireless Transmission System With Rack-Mountable Or Desktop Receiver, Stable Rf Performance With Selectable Channels/Frequencies As Permitted By National Regulations, Balanced Audio Output Connectivity, And Provisions For Antenna Diversity Or Equivalent Signal-Stability Technology To Ensure Reliable, Noise-Free Operation. The Handheld Transmitter Shall Feature Rugged Metal Construction, Secure Battery Compartment, Suitable Operating Range For Stage Use, And Compatibility With Standard Rechargeable Or Replaceable Batteries. The Receiver Shall Provide Audio Level Control, Rf/Af Indication, And Necessary Output Interfaces For Connection To Professional Mixing Consoles And Pa Systems. The Unit Shall Be Supplied Complete With Microphone Transmitter, Receiver, Antenna System, Power Supply, Mounting Accessories, Interconnection Cables, Documentation, Installation, Testing, And Commissioning, Ensuring Stable Rf Transmission, Clear Audio Performance, Electrical Safety, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Wireless Vocal Microphone Solution Suitable For Continuous Professional Use. Reference Make & Model Shure Sm 58 Approved Makes Sennheiser / Shure / Sennheiser / Audio-Technica / Akg , Digital Speaker Management System Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Digital Loudspeaker Management And System-Processing Unit Suitable For Pa, Auditorium, And Installed Sound Reinforcement Systems, Incorporating Multi-Input And Multi-Output Balanced Analog Audio Channels (Minimum 2 Inputs And 6 Outputs Or Higher) With High-Resolution Digital Signal Processing For Complete System Optimization And Protection. The Processor Shall Provide Configurable Crossover Filtering, Parametric And Graphic Equalization, Delay Alignment, Polarity Control, Dynamic Limiting, And System Protection, Along With Automatic Feedback Suppression, Room Equalization, And Loudspeaker Tuning Functions Derived From Established Professional Audio-Processing Technologies. The Unit Shall Support Front-Panel Control With Display Interface And Remote Configuration Via Computer Or Network Connection, And Shall Include Non-Volatile Memory For Storing Multiple User Presets Suitable For Different System Configurations. Audio Performance Shall Ensure Low Noise, Wide Dynamic Range, And Minimal Distortion, Appropriate For Professional Live And Installed Sound Applications. The Equipment Shall Be Housed In A Standard Rack-Mountable Enclosure Suitable For Continuous Operation, And Shall Be Supplied Complete With Power Supply, Interconnection Accessories, Mounting Hardware, Documentation, Installation, Testing, And Commissioning, Ensuring Reliable Signal Processing, Safe Operation, And Full Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Speaker-Management Solution. Reference Make & Model Dbx Drive Rack Venue 360 Approved Makes : Dbx / Xilica / Behringer / Bss Audio , Condenser Pickup Microphone System Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Miniature Condenser Pickup Microphone System Suitable For Acoustic Musical Instruments, Stage Performance, Studio Recording, And Installed Sound Applications, Incorporating A Contact-Type Or Surface-Mount Condenser Transducer With Figure-8 (Bi-Directional) Polar Pickup Pattern And Wide Frequency Response Approximately 10 Hz To 18 Khz For Accurate Vibration And Tonal Reproduction. The Microphone Shall Provide High Sensitivity, Low Self-Noise, And Wide Dynamic Range, And Shall Operate On Standard Phantom Power (Approximately 9 V To 52 V Dc) Through An In-Line Or Integrated Preamplifier Module With Balanced Low-Impedance Xlr Output Suitable For Connection To Professional Mixing Consoles And Pa Systems. The System Shall Include Non-Permanent Mounting Provision Such As Adhesive Pad Or Equivalent Detachable Fixing Method To Enable Secure Attachment To Musical Instruments Without Damage, Along With Shielded Connecting Cable, Preamplifier Interface, And Strain-Relief Protection To Ensure Reliable Stage Use. The Unit Shall Be Supplied Complete With Mounting Accessories, Interconnection Components, Protective Storage Provision, Documentation, Installation, Testing, And Commissioning, Ensuring Stable Pickup Performance, Noise-Free Signal Transmission, Electrical Safety, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Condenser Pickup Microphone Solution Suitable For Continuous Professional Use. Reference Make & Model Akg C411pp Approved Make : Akg / Audio-Technica / Shure / Dpa , Direct Injection (Di) Box Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Direct Injection (Di) Box Suitable For Stage, Studio, Auditorium, And Installed Pa Applications, Designed To Convert High-Impedance Unbalanced Instrument Or Line-Level Signals To Balanced Low-Impedance Microphone-Level Output For Direct Connection To Mixing Consoles And Audio Systems. The Unit Shall Provide High-Quality Signal Isolation And Impedance Matching Using Transformer-Based Or Active Electronic Circuitry, Incorporating Balanced Xlr Output, Parallel/Thru Output For Amplifier Feed, Ground-Lift Switch To Eliminate Hum And Noise, And Attenuation Pad Or Level-Control Facility Where Applicable. The Di Box Shall Support Passive Operation Or Active Powering Via Internal Battery And/Or Phantom Power, Ensuring Compatibility With A Wide Range Of Musical Instruments And Audio Sources. Audio Performance Shall Ensure Wide Frequency Response, Low Distortion, High Headroom, And Minimal Noise, Suitable For Professional Live And Recording Environments. The Enclosure Shall Be Of Rugged Metal Construction With Protective Finish, Suitable For Continuous Stage Use, And Shall Be Supplied Complete With Necessary Connectors, Accessories, Documentation, Installation, Testing, And Commissioning, Ensuring Noise-Free Signal Transmission, Electrical Safety, And Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Di Interface Solution. Reference Make & Model Akg C411pp Approved Make : Radial / Dbx / Klark Technik / K & M / , Additional Xlr-To-Xlr Microphone Cable (10 M Length) Supply, Installation, Testing And Commissioning (Sitc) Of Professional Balanced Xlr-To-Xlr Microphone Interconnection Cables Of Minimum 10 Metres Length, Suitable For Stage, Studio, Auditorium, And Installed Pa System Applications. The Cables Shall Be Constructed Using High-Purity Copper Conductors With Twisted-Pair Configuration, Effective Overall Shielding, And Low-Capacitance Insulation To Ensure Minimal Signal Loss, Low Electromagnetic Interference, And Noise-Free Audio Transmission Over The Specified Distance. Each Cable Shall Be Terminated With Professional-Grade 3-Pin Xlr Male And Female Connectors Featuring Secure Locking Mechanism, Proper Grounding, Strain-Relief Protection, And Durable Metal Housing, Ensuring Reliable Connectivity And Long-Term Mechanical Integrity Under Continuous Professional Use. The Outer Jacket Shall Be Flexible, Abrasion-Resistant, And Suitable For Stage Handling And Fixed Installation Environments. The Supply, Installation, Testing And Commissioning Scope Shall Include Supply Of Complete Ready-To-Use Cables, Identification/Labeling, Testing For Continuity, Insulation, Shielding Effectiveness, And Signal Integrity, And Commissioning To Achieve Stable, Hum-Free Operation In Accordance With Approved Technical Standards And Site Requirements, Forming A Complete Professional Microphone Interconnection Solution. Approved Makes: Belden / Canare / Mogami / Klotz / Nuetrik , Trs To Trs Audio Interconnection Cables Supply, Installation, Testing And Commissioning (Sitc) Of Professional Balanced Trs-To-Trs Audio Interconnection Cables Of Minimum 10 Metres Length Each, Suitable For Stage, Studio, Auditorium, And Installed Pa System Applications. The Cables Shall Utilize High-Purity Copper Twisted Conductors With Effective Shielding And Low Capacitance, Ensuring Low Noise, Minimal Signal Loss, And Reliable Balanced Audio Transmission Over The Specified Distance. Each Cable Shall Be Terminated With Professional 6.35 Mm Trs (Stereo) Male Connectors Having Durable Metal Housing, Proper Strain Relief, And Secure Electrical Contact, And Provided With A Flexible, Abrasion-Resistant Outer Jacket Suitable For Continuous Professional Use. Approved Makes: Belden / Canare / Mogami / Klotz / Nuetrik , Ts To Ts Audio Instrument Cable Supply, Installation, Testing And Commissioning (Sitc) Of Professional Unbalanced Ts-To-Ts Audio/Instrument Interconnection Cable Of Minimum 10 Metres Length, Suitable For Stage, Studio, Auditorium, And Installed Pa System Applications. The Cable Shall Be Constructed Using High-Purity Copper Conductor With Effective Shielding And Low Capacitance, Ensuring Low Noise Pickup, Minimal Signal Loss, And Reliable Signal Transmission For Instrument Or Line-Level Audio Connections. Each Cable Shall Be Terminated With Professional 6.35 Mm Ts (Mono) Male Connectors Featuring Durable Metal Housing, Secure Electrical Contact, And Proper Strain-Relief Protection, And Provided With A Flexible, Abrasion-Resistant Outer Jacket Suitable For Continuous Professional Use. Approved Makes: Belden / Canare / Mogami / Klotz / Nuetrik , Two-Way Loudspeaker With Speaker Stand Supply, Installation, Testing And Commissioning (Sitc) Of A Professional Self-Powered Two-Way Full-Range Loudspeaker Suitable For Live Sound Reinforcement, Stage Monitoring, Auditorium, And Installed Pa System Applications, Incorporating A High-Efficiency 12-Inch Low-Frequency Transducer And A High-Frequency Compression Driver With Constant-Directivity Waveguide, Driven By Integrated Class-D Amplification Delivering Not Less Than Approximately 1000 W Peak Power (Or Equivalent Continuous Rating). The Loudspeaker Shall Provide Maximum Sound Pressure Level Of About 130 Db Special Or Higher And Usable Frequency Response Extending Approximately From 50 Hz To 20 Khz, Ensuring Clear, High-Output Full-Range Audio Performance. The Unit Shall Include Balanced Xlr/Trs Combo Input(S), Additional Line/Microphone Input Capability, And Xlr Link/Thru Output, Along With Built-In Digital Signal Processing Providing Equalization, Crossover Management, Dynamic Protection, And Selectable Operating Modes Suitable For Front-Of-House Or Monitor Use. The Enclosure Shall Be Of Rugged, Acoustically Optimized Moulded Or Composite Construction With Integral Handles, Pole-Mount Socket, Monitor-Wedge Angle Provision, And Durable Protective Finish Suitable For Continuous Professional Deployment. The System Shall Be Supplied Complete With A Heavy-Duty Adjustable Tripod Speaker Stand, All Required Accessories, Interconnections, Documentation, Installation, Testing, And Commissioning, Ensuring Noise-Free Operation, Electrical Safety, Mechanical Stability, And Full Compliance With Approved Professional Audio And Site Technical Standards, Forming A Complete Deployable Powered Loudspeaker Solution. Reference Make : Yamaha Dbr Approved Make : Yamaha / Jbl Professional / Rcf Art, Qsc , Stage-Monitor Loudspeaker Supply, Installation, Testing And Commissioning Of A Self-Powered (Active) Two-Way Bi-Amped Bass-Reflex Professional Stage-Monitor Loudspeaker Comprising A 12-Inch Low-Frequency Woofer With Minimum 2.5-Inch Voice Coil And Ferrite Magnet And A 1.75-Inch High-Frequency Compression Driver In Coaxial Configuration, Providing Nominal Coverage Of Approximately 90° Horizontal × 60° Vertical With Fir-X Dsp-Controlled Crossover Around 1.8 Khz. High-Efficiency Class-D Bi-Amplification Delivering Not Less Than 1000 W Dynamic Power (Lf About 800 W And Hf About 200 W) And Approximately 465 W Continuous Output, Capable Of Producing A Maximum Sound Pressure Level Of At Least 129 Db Peak With A Frequency Response Of Approximately 55 Hz To 20 Khz (-10 Db) Or Wider. A Minimum Of Two Balanced Xlr/Trs Combo Mic/Line Inputs, Stereo Rca Input Provision, Balanced Xlr Link/Output, Integrated Dsp Processing And Protection Circuits, Housed In A Rugged Plywood Bass-Reflex Enclosure With Protective Grille, Monitor-Tilt Provision And Pole-Mount Socket, Suitable For Operation On 220-240 V Ac, 50 Hz Supply, Complete With All Necessary Accessories, Cabling, Installation Hardware. Reference Make & Model : Yamaha Dhr Approved Makes Yamaha / Jbl Professional / Rcf Art, Qsc , Analogue Audio Mixing Console Supply, Installation, Testing And Commissioning Of A Professional Analogue Audio Mixing Console With Minimum 16 Input Channels, Comprising At Least 8 Mono Microphone/Line Input Channels With High-Quality Microphone Preamplifiers, Switchable 48 V Phantom Power, Insert Points, High-Pass Filters, And Single-Knob Compressors On Selected Mono Channels, Together With Additional Stereo Line Input Channels To Realize Not Less Than 16 Simultaneous Inputs. The Mixer Shall Provide Balanced Xlr/Trs Connectivity, Multi-Band Channel Equalization With Sweepable Mid-Frequency On Mono Channels, Minimum Four Auxiliary Sends Including Effects Send, Group And Stereo Bus Routing, Peak Indication, And Comprehensive Master Level Metering. The Unit Shall Incorporate A Built-In Digital Multi-Effects Processor With Multiple Preset Programs And An Integrated Usb Audio Interface Supporting At Least 2-In/2-Out Operation With 24-Bit/192 Khz Resolution For Computer Recording And Playback. The Console Shall Be Housed In A Robust Metal Chassis Suitable For Portable Or Fixed Installation, Operate On 220-240 V Ac, 50 Hz Supply, Complete With All Necessary Accessories, Cabling, Installation Hardware. Reference Make: Yamaha Mg16xu Approved Makes : Yamaha, Allen & Heath, Soundcraft, Mackie, Behringer, Presonus, Midas, Studiomaster. , Supply, Installation, And Execution Of All Electrical Wiring Works Required For The Public Address System, Including Equipment Fixing, Speaker Cabling, Projector Cabling, Scaffolding, Carpentry, Fabrication, Conduit Laying, And Associated Civil Works, Complete In All Respects As Per Site Requirements And Directions Of The Universitys Engineer-In-Charge And Calibration, Testing, And Fine-Tuning Of The Installed Public Address System To Ensure Optimal Performance And Sound Quality, Complete In All Respects As Directed By The Universitys Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
31.
Educational and Research Institute #10851996 Price Bid
Tender for E-Tender For Supply, Installation & Commissioning Of Devices, Equipments, Instrument, Machineries, Tools Etc. For Mechanical, Electrical And Electronics Engineering Laboratories And Workshops At Kolaghat Government Polytechnic. , To Determine Illumination Of A Surface For A Drawing Room By Means Of Lux Meter. , To Determine Candle Power Of A Lamp In Comparison To Standard C.P. Of Lamp By Optical Bench Method. , To Verify The Inverse Square Law And Compare The Difference In Output Luminescence Of Incandescent, Fluorescent And Compact Fluorescent Lamps. , To Study Of Sodium Vapour Lamp, Mercury Vapour Lamp, Cfl With Their Connections And The Technical Specification. , Trainer Kit Dc Series Motor, Brake Drum & Pulley,Spring Balance , Weights, Tachometer, Ammeter, Voltmeter, Multimeter, Clampmeter, Rheostat , Electrical Load Box, Dc Gen, Braking Setup , Electric annual rate contract Welding Setup , Trainer Kit Setup Of Induction Heater , Experiment To Compare Power Consumption Of Different Types Of Tl With Electromagnetic Ballast, Electronic Ballast And Led Lamps By Direct Measurements And Estimate Energy Saving. , Experiment To Determine The Reduction In Power Consumption In Star Mode Operation Of Induction Motor Compared To Delta Mode At Different Load Conditions. , Experiment To Estimate Energy Saving By Improving Power Factor Using Pfc/Apfc For An Electrical Load. , Experiment To Estimate Energy Saving By Improving Load Factor For An Establishment. , Perform Experiment To Determine The Reduction In Power Consumption By Replacement Of Fans And Regulators In A Class Room / Laboratory , Prepare Series Testing Board For Testing Fan Or Other Electrical Gadgets. , Select The Electric Wire Using Measuring And Testing Instruments For Particular Applications. , Study And Identify Cables (Pvc, Xlpe, And Vir) And Catenary Cable Of Different Current Rating. , Prepare Wiring Installation On A Board From The Commencement Of Supply Showing Energy Meter, Mcb, Control Of One Lamp, One Fan And One Socket From One Switch Board In Pvc Surface Conduit Wiring System. , Prepare Wiring Installation On A Board Showing Control Of One Lamp, One Fan And One Socket From One Switch Board Using Batton Wiring System. , Control One Lamp From Two Different Places Using Pvc Surface Conduit Wiring System. , Test Wiring Insulation Using Megger. , Measure Earth Resistance Using Earth Megger , Measurement Of Three Phase Energy Using Static Energy Meter Which Can Show Maximum Demand, Reactive Power, Tod In Addition To Active Power. , Measurement Of Energy Using Ct And Pt , Perform Experiment To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angles Of Inclination And Plot Radiation Vs. Time Characteristics For Certain Duration. , Perform Experiment To Plot I-V Characteristics Of Photovoltaic Cell Module And Find Out The Solar Cell Parameters (O.C. Voltage, Short Circuit Current, Voltage-Current-Power At Maximum Power Point, Fill Factor, Efficiency). , Identify & Study The Specified Components Of A 0.3 Kw Small Wind Turbine (Swt) System. (Indoor Type). , Set Up The Solar Pv Plant To Produce Electricity. , Display Board Of Samples Of Overhead Conductors, Underground Cables , Samples Of Transmission Line Insulators. , Demonstrate Various System Faults By D.C. Network Analyzer , Measurement Of Three-Phase Line And Phase Voltage And Measurement Of Three-Phase Power By Two Wattmeter Method , Inductance Measurement By Andersons Bridge Trainer Kit. , Multimeter , Clamp Meter , Stop Watch , Distance Meter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
32.
Public Administrative Department #10800954 AOC
Renovation As Per Requirement And Related Electrical Works In Various Gardens Under A Zone Office (2025-26)-Providing and erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing and recording the results as per specification no. EA-EP Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying including excavation of suitable width and depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. Repairing of 120W LED Street Light fi ng with replacing of electronic type Driver 120 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 100W LED Street Light fi ng with replacing of electronic type Driver 100 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 100W LED Street Light fi ng with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes) Dismantling the existing W.T. fluorescent Fitting S.V./M.V./M.H. lamp/ LED fitting from pole with bracket complete. Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as perdesign complete (for 3 to 5m octagonal / conical GI pole). Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Supply of decorative post top pole 4 Mtrs long made from MS pipe of grade IS1239. The bottom section of pole shall be 139.7mmx4.50mm x 1000mm, and top shall be 76. 1mm x 3.25mm x 3000 mm. The pole shall have base plate of 250x250x10mm. Bottom and top pipe of the pole shall be provided with cast iron emblishment to add asthetics on the pole with the help of grub screw. The pole shall have weather proof inbuilt junction box with flush door and locking arrangements. Junction box shall be provided with 6Amp MCB, Backlit sheet and heavy duty connector. The pole shall be provided with suitable earthing arrangements. The pole shall be provided with 4Nos foundation bolts of M16x600mm with washer and nuts. The body of the pole shall be polished throughly to give smooth surface and pre treated and painted with epoxy primer and finished with UV Ray resistant PU paint in approved colour shade. SITC of Post Top Luminarie LED 3000K,<(>,<)> 240Vac CRI >80 Input power : 45W Dimension : 445 x 741 mm Light Distribu on 360° Electronic driver ON/OFF CE and BIS LUMINAIRE TYPE Light Column. IP ra ng IP65 MATERIAL CHARACTERISTICS Die cast aluminium top cover 445 mm, die cast aluminium decora ve knob on top, Gravity die cast aluminium (LM6 Grade) suppor ng arm integrated with die-cast aluminium base (LM6 Grade) suitable for moun ng Ø60mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment and pure polyester powder coa ng. LIGHTING PERFORMANCE Translucent acrylic diffuser of 2.7mm thickness with controlled downward light emission. Lamp fixed posi on. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the exis ng regula ons of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Opera ng ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, Cut off Range 440v,THD <(><<)>10%, Internal Surge protec on 6KV.External Surge Protec on 10KV. ( With 5 Years Warantee ) Opera ng Tempreture -15 Degree Tp +50 Degree and L ED Lumens 150 Lumens/Wa Supplying and installing street light feeder pillar as switching point, as per approved drawing, made from 14 SWG MS sheet of size 1.2x0.9x0.45 mtr with slanted Roof and minimum 2 Louvers on side walls, Front Single Door ( Flush / surface finish type) hinged (3 Nos) from inside with Double folded 14 SWG MS Sheet with rubber gasket on the touching face of edge. The Feeder Piller shall consist of following accessories and provisions, wired up with 16 sq.mm Copper stranded single core PVC insulated wire forpower wiring and 1.5 sq.mm single core PVC insulated copper wire for control wiring. Earthing connection stud provision on both side faces. complete as per specification. 1) 3 Nos. --- Single pole contactors 40 amp capacity of approved make, 2) 1 No. ---- digital time switch of LT/GIC or similar type as ASTRO Mini with min 1 NO contact of 7 Amp, 230 V capacity, 3) 1 No ---- MCB Version 3 pole Isolator switch 500 V 63 amp.capacity, 4) 1 No --- .Alluminium busbar of 25x4 mm, 0.3 mtr long resting on 2 nos. porcelain panel insulator/Busbar supports for Neutral Connection. 5) 1 No ---- 3 pin 6 Amp Plug socket and switch combined unit, 6) No --- Point wiring for Lamp point, with angle holder and switch on board, 7) 3 Nos. ---- 100 Amps Kit-kat Fuse annealed Copper Contacts for incoming supply. 8) 6 Nos --- 32 Amps single pole MCB mounted on D-rail for outgoing circuits. 9) 2 Nos --- Self locking arrangements with keys. 10) 2 Nos --- Earthing connection studs on both side wall minimum of M8 nut bolt. All above accessories are to be installed on Commercial Plywood of 19 mm Thick Having size1.0 x 0.8 m resting on 6 nos of supports welded on MS Sheet. Sufficient space/provision for installation of MSEDCL power Meter shall be kept. The feedar Piller shall be installed on MS Angle/iron frame fabricated from IS-MC-75- 50X50X5 mm Angle having size 0.9 (B) x 0.45 (W) x 1.2 (H) Mtr with holepass angles etc. Additional MS Sheet of size 0.9x0.45 mtr shall be welded at front and back of frame to hide the cable entries. The frame shall be grouted in earth with necessary Cement Concrete Filling including excavation in all type of strata. The MS Sheet and MS angle iron frame shall be completely painted from inside and outside with one coat of red oxide and 2 coats of ivory/red enamelled paints. The coat of bituminous paint shall be applied for portion of frame grouted in earth. The Danger Board shall be revetted at front door.(RA Item 28-4-1 (18-19) SITC of Flexible strip light with 5m meter length, Protection Rating: IP20, Power consumption: 15W/m, CCT: 5000K, (as per the design approval) Beam Angle: 120°, Power Input: DC 12V/24V with external driver, Surge Protection: Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in temperature range of 0°C to 50°C LED life time should be at least 50 ,000 burning hours at L.70 at 25 degree centigrade. Luminaire is inclusive of driver and Integral male/female connectors with structures in pre wired conditions as per IS standard. LED Makes should be CREE, LumilLED, Osram, Seoul, Epistar, Nichia or equivalent. with 5 Years of onsite warantee. SITC of BIS registered LED blue color architectural spot lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish. Luminaire offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Wattage should be 9W(±5%). Surge Protection 2 KV-4 KV.Fixture should have constant locking hinges for simple position control from various angles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaireshall be IP66 and IK08 rated. LED Life time shall be at least 50,000 burning hours at 50°C. LED should be of make Nichea, Osram, Cree, Lumiled. Luminaire shall be complete with integrated IP 66/67 potted driver and capable of operating at line voltage fro m 100-240 Vac, 50Hz with power factor > 0.9. The product should be BIS approved with R number mentioned on product label. Fixture should have power cable of minimum 600mm length. To be supported with Product test reports BIS, CE ROHS should he submited. IP66, IK08. LM79 and LM80 reports form NABL Accredited laboratory should submited priorto the supply of material. The Fitting includes all inbuilt accessories, connectors, wire etc. complete in all respect with 5 Years of onsite warantee. SITC of 50W LED RGBWW having BIS standard IS 10322 (Part 5/Sec 1): 2012 and having CE certification against standard Low Voltage Directive and Protective Equipment - EN 60598-1:2015, and Electromagnetic Compatibility Directive - EN 61547: 2009. BISregi stered LED RGBWW architectural wash lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Power input of wattage 50W(±5%). Hot spot and light distribution Optics Designed to minimize hot spots and fringing in color mixing applications. Surge Protection 2 KV - 4 KV Additional if required will be added as per the requirement). Luminaire offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have constant locking hinges for simple position control from various angles without special tools. Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK08 rated. LED Life time shall be at least 50,000 burning hours at 50°C. ED should be of make Nichea, Osram, Cree, Lu miled. DMX enabler circuit should be inside the Luminaire only Luminaire shall be with remote driver with output voltage 24V DC.The product should be BIS approved with number mentioned on product label. Fixture should have power cable of minimum 600mm length and signal loop in-out cable of minimum 600mm with IP68 male-female connectors.To be supported with Product test reports BIS, CE RoHS should be submited. IP66, IK08, LM79 and LM80 reports form NABL Accredited laboratory should submited priorto the supply of material. The Fitting includes all inbuilt accessories, connectors, wire etc. complete in all respect with 5 Years of onsite warantee. Repairing of 60W LED Street Light fiti ng with replacing of electronic type Driver 60 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 135W LED Street Light fiting with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes) Repairing of 60W LED Street Light fi ng with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes)
Contract Date: Mar 09, 2026 Contract Value : 21.17 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
34.
Water Resources and Irrigation #10775900 Price Bid
Repair Of 15 Ton Electric Overhead Traverse (Eot) Crane Along Other Allied Accessories / Works Installed At Tph, Jammu-Repairs to 15 Ton EOT crane by way of disconnecting main supply of EOT Crane, decoupling gearbox from 10 HPmotor, dismounting Gear box from Trolley to the Ground by suitable means,Repairs to gear box by way of dismantling, checking, cleaning of the gear box housing/parts with kerosene oil/diesel, P/F new driven shaft- 01 No. , bearingof gear driven shaft(APS) - 01 No., Oil seals-08 Nos.,assembling, mounting and fitting gear box at its position after replacement of damaged parts. Refilling of gear box with gear oil by providing and filling new gear oil up to required label(15 ltr). Repairs to brake system of E.O.T Crane by way of complete servicing of 02 no. brakes(thruster & electromagnetic) includingreplacement ofBrake coil of electromagnetic brake-01 No., Break leather set of both brakesalong with requisite no of tension springs, rivets, nuts, bolts , brake drum(APS) of electromagnetic brake- 01 No with providing and fitting new one. Providing and filling brake oil- 01 ltr. Repairs to control panel of E.O.T Crane by providing & fitting new contacts & magnetic coil to 02 no. contactors of Siemens make. Providing & fitting new contactor of 25 Amp. 3 pole, 230v-02 no. in place of damaged one. Replacement of HRC fuses 03 no. Replacement of damaged cable hangers of 04 core service cable of E.O.T by way of providing & fitting 12 no. new cable hangers. Complete job includes testing and commissioning of E.O.T Crane on load. Job includes material & labor cost including charges for all tools & tackles required for execution of job. 2 Ravi Canal :- D-18 H/R, DOL Vijaypur.Complete Job.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
37.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
38.
Textiles #10732252 AOC
Supply, Installation, Testing And Commissioning Of Cctv Surveillance System At 140 Warehouse Locations-2 Supply & erecting of high defination 5 MP IP IR Bullet camera with Sensor : 1/3, progressive scan, 5.0 megapixel, CMOS, Lens : [email protected]/ [email protected], Shutter Speed : Auto/Manual, 1 ~ 1/100000s, Digital noise reduction : 2D/3D DN, Day/Night : IR-cut filter with auto switch (ICR), Minimum Illumination: Colour: 0.03Lux (F2.0, AGC ON) 0Lux with IR, IR Range : Up to 30m (98ft) IR range, S/N : >56dB, Defog:Digital Defog , WDR: DWDR/ True WDR, Resolution : 5 MP or better ( 2592x1944), Video Compression : H.265 / H.265+, High Light Compensations : TRUE, Back Light Compensations :TRUE,Network : 1 RJ45 100M Base-TX Ethernet, Audio : Audio In / Out Support,Power : 12V DC / PoE, Housing : IP67 , CERTIFICATION : Vendor should submit Mfr. Test Certificate,Cyber Security : AES 256-bit Encryption, Configuration encryption, trusted execution, digest, security logs,WSSE ,account lockout,syslog, video encryption, IP/MAC filtering ,HTTPS,Trusted upgrade,trusted boot., ANR Support : Yes with 512 GB For details technical specification no 13. 3 Supply, installation, testing and commissioning of 8 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 8 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 8-ch@1080P(30fps), 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 160 Mbps, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 2 SATA ports, up to 10TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz/Single, DC12V/4A , Power Consumption : <9.5W (Without HDD) , Certification : UL,CE,FCC,BIS For details technical specification no 16. 4 Supply, installation, testing and commissioning of 16 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 16 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 300 Mbps or better, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 4 SATA ports, up to 16TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V/Single, DC12V/4A , 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 15. 5 Supply, installation, testing and commissioning of 32 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 32 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 32-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 320Mbps, Video Display Split : 1st Screen: 1/4/8/9/16/25/36, 2nd Screen: 1/4/8/9/16, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports, Hard Disk : 4 SATA ports, up to 20TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 14. 6 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD 7 Supplying & erecting( 32 Monitor ) 32 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc.complete. 8 Supplying & erecting (43 Monitor ) 43 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 9 Supplying & erecting (49 Monitor ) 49professional LED display with 1920*1080 (Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 10 Supplying, erecting & terminating 5 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. 11 Providing & erecting 7 m high (clear height) galvanised Each octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL. 12 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mmstonemetal,(45 x45 x45)cm/45cmdia.x45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 13 Supplying and erecting Lshape mounting for camera (Extender) etc complete as directed by engineer in charge. 14 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of 24 ports 10/100/1000 Base-T PoE+ ports with min 180W power and 2x 1G SFP portsand 1 x Out of Band IP based management Port with CL1 provided, switch of min. 36 Gbps or morewith non-blocking architecture forwarding rate of 26.8 Mpps rack, equipped with minimum 512MB RAM and 128MB flash, should have LED indicator for per port status, FAN, PSU and Management status and sustain 0°C to 50°C OT and 10% to 95% RH as directed. It should support for IPv6 , cover transmission distance of 250 meter. The swithching and routing should have 16 K MAC Address, 255 active Vlans, 802.1D spanning Tree, 802.1w, 802.1s, should have BPDU Guard, support aggregating and load balancing, 802.1 AK for dynamic VLAN propagation, Local and Remote port mirroring, Link Layer Discovery Protocol (802.1ab), MAC address tracking and address addition, delete or movement. The secutrity LA database for RADIUS Authentication for 802.1x login, SSH-2, SCP for secure management, dynamic arp inspection, DHCP snooping with min50 ACL entry support. Management should consist scheduled archiving / uploading of configuration and system log to a central server, Auto-install support for firmware images and configuration files and vendor shouldsubmit Mfr Test Certificate along with supply as directed by Engineer in chargeas per technical specification no. 1 complete. 15 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of8 Ports 10/100/1000 Mbps PoE+ 2 nos of1G SFP Ports, 2 Uplink ports, Protocol: IEEE802.3af, IEEE802.3at, Hi-PoE, consumption of PoE Budget: 120 W, with switching capacity 20 Gbp, FR rate 11.90 Mbps, buffer memory 1.5MB, should covertransmission distance 250 meter, MAC Address List- 8k. The lighting protection 6KV, working temperature –10° C to 55° C (14° F to 131° F), Electromagnetic- FCC CFR 47 FCC Part 15 Subpart B, Conforms to CE Standards. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in chargeas per technical specification no. 2 complete. 16 Supplying & erecting Mode SFP transceiver of Single LC receptacle optical interface compliant with 7dB gainetc model, Hot-pluggable SFP footprint type, OW of 1310nm FP laser transmitter, standard RoHS compliant and Lead Free, should reach Up to 10 km on 9/125um SMF, with Metal enclosure for lower EMI, Low power dissipation <600mW, should sustain 0~50°C, Same as Switch make, Vendor should submit Mfr Test Certificate along with supply and complete as directed by engineer in chargeas per technical specification no. 3 complete. 17 Supplying and installing UTP CAT6 copper cablesuitable for networking of type 23 AWG Solid Bare Copper, Unshielded Twisted 4 Pair, Category 6, LSZH jacket complying to testing, cable outer diameter of 5.8mm, frequency 600 MHz; ETL Test Reports of ANSI/TIA-568-C.2 & ISO/IEC 11801 of cable performance upto 600 MHz provided conduit/casing-n-cappingas directed by engineer in charge and per technical specification no. 11. 18 Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC 19 Supplying and fixing 1 m UTP patch cordof Cat 6 type Electrical performance guaranteed to meet or exceed TIA/EIA 568-B 2-1 category 6 and ISO /IEC Category 6/class,certification UL listed, UL-C certified, different color (Green, orange and red with connector complete as directed by engineer in charge and submit mfr test reportas per technical specification no. 12 complete 20 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 21 Supplying and installing 6 core Optical Fiber unarmored cable unitube gel filled for access outside building Single Mode, 9/125 microns, bending radious of not more than 20X , 10 GBPS speed compliant to IEC 60793/IEC 60794 standards, change in Attenuation < = 0.05 db/km, Tensile strength >=300 N, Maximum Crush Resistance 1000 N/100mm,OT of -300 C to 500 C, storage temperature of -400 C to 550 C, of standards ISO/IEC11801 TIA/EIA-568-B, Vendor should submit Mfr Test Certificate along with supply complete as directed by engineer in chargeas per technical specification no. 6 complete. 22 Power Cable (MCB with closed box, single phase) -Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper m PVC unarmoured cable provided conduit/trunking/inside pole/Bus bars or any other places. as per technical specification No: 17 23 PVC Conduit with Hanging wire -Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-12) 24 Supplying and fixing 6 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fiber cables in provided U rack complete as per specification no. WG-NAS/ LIU 25 Supplying and fixing LIU 12 Port loaded SM with SC connectors ports provision for 12 Nos. of SC Termination. light guide unloaded interconnect unit, rack mounted type, with adapter panel Fully loaded with SCtype duplexfor termination of optical fiber cables, 19 Rack mountingin provided U rack complete as per technical specification no. 7. 26 Supplying and erecting 12 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 12 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge.Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 27 Supplying and erecting 6 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 6 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge. Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 28 Supplying and installing single mode simplex pigtail with SC/LC splicing, SC Connector with single mode fiber pigtail (To be used for arc fusion splicing with Fiber cores termination inside LIU/fiber interconnecting panel.) Pigtail consists of pre-moulded/prefabricated SC type fiber connector at one end & another end fiber core with approx. 1 meter length as directed and Vendor should submit Mfr. Test Certificate along with supplyas per technical specification no. 10 complete 29 Supplying and erecting duplexOFC patch cord SC-LC typefibre patch cord, SC-SC /SC-LC duplex, of 1 meter lengthetc complete as directed by engineer in charge. Vendor should submit Mfr. Test Certificate along with supply.as per technical specification no. 9 complete 30 Supplying and fixing 6Uwall mount rack or better, Two Vertical and 2 horizontal cable managers, PD of 5 points- 5 AMP socket, depth of 550 mm or as per NVR sizing, Aluminum extruded profile,compliance CE & RoHS , Glass door in front with lock, With min 2 fans for outdoor,19” equipment mounting or extra width, with 1 tray, should confirm standard of DIN41494 or equivalent ISO9001:2015 and 14001:2015. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 5 complete. 31 Supplying and fixingOutdoor 4Uwall mount rack or size as per requirement; bidder to study each PoP location and confirm size in technical and commercial offer, one Vertical and one horizontal cable manager if required, power distrubution with min 3 points- 5 AMP socket or as per site requirement, depth of 400 mm, Aluminum extruded profile , IP rating of 67 if outdoor use,Glass door in front with lock or metal door with perforations, fan type ventilation to be provided for outdoor unit as per requirement at site. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 4 complete. 32 Supplying, erecting, testing and commissioning of 2KVA online UPS with Isolation Transformer& 2 KVA = 2 KW capacity online pure sine wave UPS, with batteries PWM & IGBT based, with 0.9 to unity output pf complete with all protections as per technical specification no. 18 complete.
Contract Date: May 15, 2026 Contract Value : 7.88 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
42.
Banking and Finance #10607564 Price Bid
E-Tender For Procurement Of Equipments For Siep -1 Pre- Vocational Unit 2 Children Wall Bar -n(•tThe Size should be : 85*52*168cmn•tMust be Use full for children to do standing and sitting training with the help of wall bars and muscle strength training as well as trunks traction and extension training.) 3 Children PT Stool(adjustable) -n(•tMust be use full for Used for children PT training.n•tIt must have Wheelsn•tIt should have Blue Leather Sitting) 4 Finger Correcting Board -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 4 holes) 5 Finger Correcting Board(with universal wheel) -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 3 holesn•tIt Should have 3 or 4 Wheels) 6 Hydraulic children step trainer -n(•tSize Must be: 70*56*97cmn•tWeight not more than: 29kgn•tUse full for lower limbs range of motion and muscle power training.) 7 Training Quoit -n(•tIt must be Use full for hand-eye coordination and perceptionn•tIt must be Use full Cognition training.) 8 Word cognitive puzzle –n(•tWeight not more than : 3.3Kgn•tMaterial must be: wooden) 9 Cognition Toys – n(•tSize should be: 30*30*30cmn•tWeight not more than: 8.7kgn•tShape must contain following:n-tCube 5pcsn-tCylinder 5pcsn-tTriangular 5pcsn-tCuboid 5pcsn•tIt must be use full for perception function training.) 10 Intelligence develop assembly – n(Size must be: 32.2*28.7*23.5cm) 11 PHYSIO-OCCUPATIONAL THERAPY UNIT 12 Treadmill- 2HP Noiseless AC motor 13 Short wave diathermy- 500W with valve 14 Bolsters of different sizes 15 Puzzle - Body parts with two facial expressions with box, Animal, Birds, fruits, transports, Different shapes 16 Shoulder CPM 17 Lower extremity CPM 18 CP chair 19 Static cycle 20 Bed cycle 21 weighing scale 22 texture fruit tree 23 Ball pool (48X 48) 24 perdue peg board 25 exercise mats - 6X3 26 exercise frame - rope mess, pip ladder and rock climbing board 27 Trampoline (48 Inch) 28 Quadriceps Table with detachable backrest 29 Stethoscope 30 blood pressure appratus 31 Goniometer – 180 & 360 degree 32 Electronic stopwatch 33 Digital weighting machine 34 Treatment trolley 35 Stainless steel stools 36 Tables 37 Chairs 38 Waiting chairs 39 Cupboards 40 Computer 41 Printer & scanner 42 Muscle stimulator Combo- with Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic and TENS 43 Micro control 4 channel tens 44 Weight cuff- 1/4 kg, 1/2 Kg, 1 Kg, 1.5 kg -n(•tStrengthens weak muscles through load resisting exercises of both upper and lower limbs. n•tLead shots filled cuff is double sewn and had long wrap around straps to hold weight cuff securely in Place. n•tA full set consists of 4 color coded cuffs i.e. Capacity: 250 gm, 500 gm, 1 kg, 1.50 kg) 45 Thera band- different colors and ranges – n(•tTheraBand Rubber Latex Less Bands should be supplied with 5 feet length, 4-inch width of different colour (Yellow, Red, Green, Blue, Black) - Set of 5n•tIt should be Latex Less, No Scent, No Powdern•tColour-coded Progressive Resistance system should allow users to recognize improvement as it happens – when the patient grows stronger they can move up to the next color, for strength training and physical therapy programs. Colour-coded levels should be increasing in difficulty from Yellow to Black) 46 Thera putty with different colors & ranges – n(The system should have following parameters:n•tColours options : Tan, Yellow, Red, Green, Blue, Greyn•tWeight must be: 100grams eachnHigh Resistance Level)n 47 Portable shoulder exerciser with pronation supination arrangement 48 Grip exerciser 49 Hand Gym Kit Board –n(Laminated exercise boards with storage drawer, have several holes to fix Pegs and springs. The unit permits active flexion and extension exercises of the finger and grip.nSpecification:nHand Gymkit Board consists, One finger Disc, One Roller, Three Spring loaded Knobes, 3 pegs to support finger and 3 Sets of Springs of different tensions) 50 Wrist roll -n(The unit should have following parameters:n•tOne piece SS roll with three different diameters i.e. 30mm, 40mm and 50mm to be fitted on a laminated board n•tBoard size: 25cm x 80cm long with adjustable friction control mechanismn•tControllable from zero to maximum for flexion and extension exercises of wrist and forearm) 51 Rope pulley handle set –n(Shoulder Pulley Unit with rope adjustment system (Wall Mounting)n•tShoulder Pulley unit should provide exercises of the Elbow and shoulder. n•tTubular steel constructed unit should come with Pulleys, Nylon Rope, Handles and Wall fixing frame.n•tPulleys: Two, Nylon pulley n•tHandles: Two, spring steel wire handle with plastic grip.n Rope/Cord: Interwoven Nylon cord of suitable length.) 52 Upper extremity work station -n(should have facility of peg board, pinch tree, pipe assemble unit PVC, 25 holes peg board, multi shape peg board, hand tool test frame, finger dexterity board, door latch board, dressing board set, shoulder deduction ladder, bilateral shoulder ladder, hand exercise board Velcro, hand gym board, trolley with lock) 53 Vestibulator with facility of Platform swing, flexion disc, frog swing, Lycra swing , Bolster swing rectangular 54 Vestibular board - 3.6 X 2.6 X 7 – n(Vestibular Board should be of large size for rocking the body on board stimulates balance control with Vestibular Responses. nThe top should be of thickly upholstered and covered with rexine and washable fabric cover) 55 Scooter board – n(•tBoard with 4 Wheels (90cm Long x 30cm wide): It should help the child to learn body control, shifting weight, changing directions and maintain balance. Wooden Scooter Board with foam padded top should be used in a sitting, kneeling or prone position for developing strength of the upper and lower extremities.n•tIt should have ply-wood base, supported on 25mm x 25mm angular iron frame.n•tIt should have high density Foam padded top is 25mm thick & to be covered with nylon fabric in two Colours.n•tIt should be fitted with (4) four, 50mm dia castors.n•tBoard Size should be: 90cm long x 30cm wide) 56 Wedges of different sizes – n(•tWedges with set of four size: A: 15x60x70cm; B: 20x60x70cm; C: 25x60x70cm; D: 30x60x70cm) 57 Post box with 25 plates -n(•tSorting, Matching & Posting Box unit should measure an individual basic level of function in the area of colour identification and Eye-hand co-ordination.n•tConstruction of the box should be Laminated Wooden with five multicolour plastic plates fixed at the top with five Slots to Post matching colour plates there in.n•tIt should have 25 well-polished plastics plates in 5 different colors to sort, match and post.n•tBox should come with five compartments to be fitted with sliding door to store plates and also works as posting box.n•tIt should be Natural polished finish with laminated tops & door.) 58 Door latch board –n (The frame set provides learning opportunity and progressive development of dexterity. nWith six laminated doors, opening in different directions. nEach door opens into a shelf where a reward or toy can be kept. nCommon hardware of different designs, generally used in the home is used to familiarize Patient. Size of laminated unit is 26x18x5 deep.)nnn 59 Floor seater – n(•tFloor sitter should be useful for the child who cannot sit up on his own, and who needs his shoulders and upper trunk supported.n•tThese Floor Sitters must offer support in seating a child at floor level. This must allow the child to be independent, with hands free for play, while maintaining optimal erect trunk alignment.n•tConstruction: It should have Wooden Corner Seat, with broad base that help to prevent tipping.n•tSeat & Back should have Sitter with foam padded Seat, Sides and Back support.n•tAccessories should include abductor block, hip positioning belt & removable tray should be integral part of the floor sitter.nSeater should be finished in natural wood polish. Seat & Back to be covered with multi-colour Rexene) 60 Stand in table with Standing Metal Frame – n(Basic standing frame, with comfortably supports weight- bearing parts of the body. nIt Helps to prevent atrophy of leg muscles, improves range of motion, helps improve circulation, lessens muscle spasms and contractions n Three straps should be provided for heel, ankle and pelvic support) 61 Tunnel – n(•tCrawling tunnel Non-folding, Aluminum sheet with windows on sides and inner area padded with foam should be suitable hospitals with multiple patients.n•tTunnel Set of three parts with windows on sides are padded with soft Eva foam inside. n•tIt should be made in three parts of 90cm long each, all the three tunnels should be fixed together to make a single tunnel of 2.75 meter length.n•tInside Diameter should be 50cm dia.) 62 Treatment Plinth– 63 Wooden blocks of different heights- set of 6– 64 Peanut ball– n(•tIt can help you achieve muscle and tension release for all parts of the body.n•tPeanut shape design, convenient to use.n•tSuitable for yoga, Pilates, etc., help you has better fitness effect.n•tMade of durable PVC material for long term using.n•tFeatures: Peanut Shape, Inflatable, Explosion-proof, Durable, Fitness Tooln•tSize: 45cm x 95cm/17.72 x 37.40 (Approx.) 65 Staircase– n(•tStep arrangement: FOUR 15cm steps on one side, leading to platform size 75cm x 75cm. First step moves into the second to make it a bus step of 30cm height. 7.5cm steps on the other side. Steps are 75cm wide & 23cm deep (approx.).n•tFitted with 2 sets of handrails at different height to accommodate Adults & children. n•tSteps and Platform are made of commercial board of 12 mm thickness & covered with non-slip matting. n•tSides & Supporting frame of Steps are made of commercial board of 18mm thickness with hardwood reinforcement. n•tHand Rails & supporting bars are made of solid hardwood. Stairs finished natural) 66 Parallel bars with platform-n(•tParallel Bars should have adjustable Height & Width with PVC. n•tOuter uprights of thick steel tubing0 of 50mm dia. with Powder coating finish. n•tPlatform: Tubular steel reinforced platform with incline on both ends & is covered with non-slip matting. n•tLength: about 10feet n•tAdjustments: Should be easily done by means of setting Pins at the required holes & should be stabilized by tightening the screws. n•tFinish: Working Parts are with powder coated / chrome plated finish & wooden parts with Natural polish finish.n•tCovered with non-slip matting.n•tPostural Training Mirror: Mirror should be of size 175cm x 53cm (approx.) and should be protected by hardwood polished frame with back covered by ply board. n•tStand: Mirror should be fitted on tubular stand with powder coated finish) 67 Suspension framenSuspension Frame (with Accessories) without Bedn(•tSuspension Frame set for complete Suspension with Slings & Ropes. n•tTop Mesh should facilitate suspension at any desired point in relation to the patient and as required in each individual case. n•tConstruction: Tubular steel frame with 6mm thick Rod-mesh at Top and on Upper Sides. n•tLegs should be fitted With Rubber/PVC Shoes.n•tSizes: Overall sizes 210cm long x 110cm (approx.) wide at the base, 50cm (approx.) wide at the top & 190cm (approx.) high.) 68 Stability Disc–n(It should have balance Cushion - an Inflatable cushion that must come with 2 different surfaces that introduce an element of stability to a workout, must be ideal for both balance and core training. The balance cushion must allow users to exercise and working to stay balance; with constant micro movements that will strengthen the core muscles and improve postures. It should have the benefits of using Balance Cushion. Strengthen core muscles and improve postures required. Diameter- 33 cm required. Colors required: - Lime Green(Spiky Surface), Blueberry (Smooth Surface)) 69 Vibrator (with 6 attachments) – n(•tThe unit should be able to vibrate against the body and stimulate the nerves for a relaxing feeling.n•tIt should give horizontal circular motion which effectively relieves muscular fatigue and pain.n•tIt should have following two speeds:n•tHigh with rpm 3500n•tLow with rpm 1500n•tIt should have cooling system for continuous use so that massage can be done for long time.n•tIt should have durable body for professional use.n•tIt should be heavy duty and the weight should be above 2.5 kg.nIt should have two handles for applying pressure on the chest/muscle group.) 70 Ramp and curb– n(CURBS AND RAMP (without handrails) Hardwood constructed training set consists of ONE ramp and THREE nested curbs stored below the ramp. The ramp graduates from 20mm to 200mm and is 84 X 44. The curbs are 40x 40x 6, 36x 36x 4 and 32x 32x 2 respectively. Natural wood finish with anti-slip safety mats on ramp and curbs without handrails) 71 Balls for ball pool– n(It should have brightly colored balls encourage movement plus give child visual & tactile feed-back and support. * Size of ball should be of 7cm or 8cm dia with different colors) 72 Ankle exerciser-n(Painted aluminum boot with strap to hold the foot is mounted ona laminated base with Stainless steel sheet bracket having two springs for ankle (Dorsi and Plantar flexion) exercises. nResistance can be increased further by tightening springs nut. nDegree of flexion can be measured and recorded) 73 Walker with 4 castors - non folding-n(Walking Aid Folding & Adjustable HeightnLight weight, painted aluminum tubular construction, folds easily and quickly. Height of frame is adjustable from 75 c.m. to 90 c.m. by slipping locking pins in proper notch. Fitted with soft PVC hand grips and shoes) 74 Circle balance disc-n(•tThe board should have encourages Balance and Neuromuscular Re-education, Rhythm, Coordination and Vestibular responses. Children can use it in kneeling or standing position.n•tTop Diameter should be 51cm round, cushioned top covered with rexine.n•tBase must be fitted with semi-circular base, 60mm height.n Hand-Holds must be of Two, Side holds to be provided for stability) 75 Board for lower extremity - standing exercise 76 Foot placement ladder– n(•tIt should be useful in early walking with balance training. n•tShould be of wooden floor ladder with adjustable dividers, n•tShould offer various walking patterns. n•tSteps should be of equal size and alternately placed for right-left progression.n•tBeams & Dividers should be made of Teak-wood with size 96 long x 27 wide.n•tBeams should be finished in natural wood. n Adjustable 16 Divider bars should be finished in different enamel colours) 77 Graded spring set– n(•tSuspension Springs should be made out of best steel wire, with chrome plated finish; the rope is fitted in the spring to avoid overstretching.n•tTension of the springs must be: A. 5 kg-7kg., B.8kg-10kg., C. 12Kg-15kg. D. 18kg-20kg., E. 22kg-25kg.n•tSet should consist of ONE spring each (A+B+C+D+E) with S hooks.n•tIt should be Suitable for Extension, Flexion and Suspension activities.n It should be Full Set of 5 springs) 78 Long Handle thick grip spoons-n(•tIt should have stainless Steel long handled spoons, with smooth spoon tips.n•tThe spoons must help child/baby to master fine motor skills.n•tThese spoons must be easy to clean and maintain.n It should have set of 05 pieces) 79 Tactile balls for grip-n(•tIt should have Bumpy sensation when these are squeeze by hands. Knobby surfaces and bright colours should promote sensory and tactile exploration and it must help develop fine motor skillsn•tIt should have soft and squeezable material easy for small hands to grab and promote hand-eye coordinationn•tIt should have soft, knobby surface to provide massage stimulation for little ones. n•tIt should be supplied with Set which includes (06) toys in assorted colours and shapes (Round, Square, Cone, Pyramid & Rectangle etc.).n•tIt should be BPA, Latex and Phthalate freen•tIt should be helpful to build and define childs gross motor skillsn It must be Capture childrens interests and Hearts) 80 Lotca battery test-n(•tIt should have the plan to provide the appropriate therapy. n•tThe DLOTCA (Dynamic Lowenstein Occupational Therapy Cognitive Assessment) battery must design to offer this type of critical assessment. n•tThe DLOTCA battery must measure the cognitive abilities of those with neurological impairments or injuries.n•tIt should have a set of minimum 28 sub-tests analyses the cognitive areas pertaining to: Orientation, Awareness, Spatial Perception, Visual Perception, Vasomotor Construction, Praxis and Thinking Operations. n•tThe DLOCTA should be supplied with full kit with the following Components: Instruction manual authored by top leaders in the occupational therapy field Test booklets and score sheets Card and shape sets for various sub-tests.nPegs and peg-boards must have followings…n•tTen 1 x 1 natural wood blocks.n•tFour 1 x 1 blue wood blocks.n•tTwo 1 x 1 orange wood blocks.n•tThree 1 x 1 green wood blocks.n•tOne 1 x 1 yellow wood block.n•tButter-fly puzzle. Photo book.n•tSafety scissors.n•tPencil, paper and envelope.n•tCarrying bag.n•tThe kit is compact for easy transportation weighingn•t8.5 pounds and measuring 4.5 x 10.5 x 16.5 inches.) 81 Minnesota test-n(•tIt should measure manual dexterity of the Arm and Hand for manipulative work, utilizing a broad range of shoulder motion.n•tTest should involve Turning, Placing or moving the discs in a prescribed manner. Requires unilateral & bilateral movements.n•tTests should include 60 two colored plastic cylinders, plastic board, record forms and carrying case) 82 Exercise frame - rope mess, pip ladder and rock climbing board 83 Tilt Table– 84 Wobble Board– n(•tAnti-Slip Wooden Wobble Balance Board for Fitness & Training Rehabilitation Exercisen•tHigh Quality Material And Durable: Consisting of quality wood and tough plastic base, highn•tStrength, enduring for daily training.n•tStrength Stability: The balance board also enhancing the muscle strength of waist and n•tAbdomen, beautifying the hip muscle.n•tRotatable: The can support 360 degree horizontal rotating when placing it on flat ground.n•tKeep Balance: Stimulating posture conditioning, strengthening the stability of the vestibular.n•tOrgans and improving the bodys balance.n•tWidely Usage: The balance board is suitable to be used for hemiplegia stroke and other post-balance rehabilitation training.n•tWarranty not applicable for this product) 85 Cryo Therapy Unit–n(•tTherapeutic device should be capable to produce a real deep thermal shock effect.n•tThe thermal shock is a physiological stress should produce by sudden or rapid temperature variations in the local tissues.n•tThe system should not only allow performing cry therapy or hyperthermia separately but also and above all thermal shock therapy in a dynamic and controlled way.n•tHyperthermia, transdermal cryothermica and thermal shock can be modulated in depth and intensity.n•tShould be equipped with a treatment head based on the technology of Peltier cells capable of generating heat or subtracting heat in a range from +45°C to -18°C.n•tA special sensor should transmit the target temperature and the local body temperature should appears on the LCD screen in real-time to inform the operator how the therapy is acting on the patient.n•tAll the functions should be visualized on a large color LCD in addition to the usual and traditional keys and buttons,n•tShould be possible to adjust every parameter on the touch screen.n•tThe versatile Windows CE operating system should ensure possible upgrading.n•tShould have availability of a wide range of preset protocols with body maps. n•tThe screen should show the body parts to be treated and the unit should suggest the parameter values to set after selection of pathology is chosenn•tShould have free memories for entering customized protocols.n•tTemperature: from +45°C to -18°Cn•tShould have Colour touch screen displayn•tCompact unit with dimensions: 41 x 42 x 18 cm or smallern•tLight Weight: Not more than 9 kgn•tSafety class: class I type B, class IIa) 86 Electrical traction with 3 fold Bed-n(•tThe traction unit should consist of set of mechanisms for relieving pressure on the skeletal system.n•tIt should have a large LCD display panel showing all parameters.n•tIt should have at least 8 different modes (a) Intermittent (b) Static (c) Progressive/ intermittent (d) Progressive/ Static (e) Progressive/ Regressive (f) Cyclic /Intermittent (g) Cyclic / Static (h) Cyclic tn•tIt should consist of automatic calibration of traction force to maintain correct traction force.n•tIt should have high/low force range of 1-90 kg/0-89 kg.n•tIt should be possible to apply cervical as well as lumber traction with the machine.n•tIt should have adjustable hold and rest time range of 0 –99 sec.n•tIt should have selectable ramp steps of 2-8 steps with selectable pause time of 2-20 sec. for each step.n•tIt should have 5 different pulling speeds.n•tIt should have memories storage of at least 30 treatment patterns.n•tIt should have timer of 90 minutes.n•tIt should be supplied with Fixed Height Traction bed (Indigenous).n•tShould be supplied complete with Traction Unit, Cervical Harness ,Pelvic Harness, Spreader Bar, Patient Switch) 87 Treatment couch– n(HIGH-LOW TREATMENT TABLE (Electrical)nElectric, variable height, three section table is suitable for all treatments, including manipulation both ends elevate so that the back or legs can be raised without turning the patient. One ends also lower -20 deg. for some postural drainage & manipulation techniques and more comfortable sitting. The foam padded top is 195 cm long and 70 cm wide. Table height is adjustable from 50 cm to 90 cm. Frame-work in light blue oven baked finished) 88 Pain Relief System -n(•tCombination therapy unit with Heat, magnetic force and micro vibrations.n•tThe system should be modern with touch button operation.n•tThe system should consist of two channel unit with 2 hot packs for simultaneous use.n•tIt should have flexible heating pads emitting dry heat so that it can be used over clothes in normal conditions.n•tThe heating pads should have four steps temperature control from 35º to 60ºC.n•tMaximum temperature should not exceed 65 deg for patient protectionn•tIt should provide vibrations through flexible heating pads which help in the stimulation of blood flow on painful areas.n•tThe system should have three different types of micro vibrations as below :notRipple wave: - 70 vibrations per secondnotRandom wave: - 120 vibrations per secondnotBig wave: - 60 vibrations per secondn•tIt should also provide Magnetic force for improving the blood flow.n•tMicro vibration should be from alternating magnetic fieldn•tIt should have digital timer of 30 minutes duration.n•tIt should be supplied with an imported trolley and should work on 240 V/50 Hz power supply.n•tIt should UL, and ISO 13485 approved for patient safety) 89 Wheel Chair for Children– n(The system should have following parameters:n1.tPediatric Wheelchair, Aluminum Chair frame, fixed armrest, Detachable footrest, Drop-back handle, solid castor, pneumatic rear wheel, Anti-tippers.n2.tLoading weight should be minimum 100 kg) 90 Club foot Passive exerciser & Therapy System – n(•tThe CPM should be for treatment of the idiopathic club foot which should restores or maintains ankle and subtalar mobility in addition to preventing fibrosis and periarticular soft tissue changes.n•tThe CPM should be used in the post-operative phase of treatment.n•tThree dimensional movements should be possible:n•tPlantar flexion to Dorsi-flexionn•tAdduction-Varus to Abduction-Valgusn•tPlantar flexion-Adduction-Varus to Dorsi-flexion-Abduction-Valgusn•tDigital controls should allow easy programming.n•tAt rest or working the machine should maintain a light axial traction which off-loads the pressures which are applied to the ankle mortise to avoid any deformation of the tibio-talar joint line.n•tThe machine should be equipped with a system which reverses the movement when abnormal forces are detected.n•tIt should be European CE approved) 91 Children Medical Cycle-n(•tUpright Ergometer for physical abilities such as workload etc. n•tIt should be able to work continuous work load range from 7-1000 watt.n•tIt should work for minimum five minutes at a peak load of 1000 watt for short period.n•tThe work load should be adjustable @ 1 watt increment.n•tIt should have 7 inch touch screen programmable LCD display to show various parameters such as distance, torque, power, energy and time on its control panel.n•tIt should provide workload in hyperbolic, linear and fixed torque modes.n•tIt must have eddy current electro-magnetic braking system.n•tIt should have USB interface.n•tWorkload accuracy should be = 5%.n•tIt should display distance, torque and time on its control panel.n•tIt should have Rotatable height adjustable handlebar redundant, rotate at 360 degrees for comfortable at every seating height. n•tIts seat should be sleeplessly adjustable.n•tIt should comply with MDD 93/42/EEC, incl. IEC.) 92 Ultrasound- 1 and 3 MHz Frequency – n(Digital Dual Pre Programmable Ultrasound therapy unit with constant digital LCD display adjustable treatment should be supplied having following parameters: n?tNominal Frequency: 1MHz & 3MHzn?tPower Density : 0-3W/cm2 (Approx.)n?tMix Acoustic output: 15W (Approx.)n?tUltrasonic Output : Continuous- 2.5 W/cm, Pulse- 3.5 W/cmn?tPulse Frequency: 8hz, 16hz, 50hz, 10hzn?tPulsed Ratios: 1:1,1:4,1:7,1:10n?tTimer: 0-99 minutesn?tVoltage:220 V,50Hz±10%nAccessories to be supplied:n•t1 pair - Ultrasound Head (1Mhz) & Wiren•t1 pair - Ultrasound Head (3Mhz) & Wire n•t1 pc - Main Cord) 93 Computerized Interactive Dynamometer System:-n(Computerized interactive dynamometer system should have following specifications;n•tThe system should comprise of user-friendly and easy-to-control rehabilitation robot to allow rehabilitation Training with dynamically changing resistance, diagnostics, patient evaluation and interactive games.n•tThe system should be upgradable to make use of reactive electromyography (EMG) for neuro exercise. n•tSingle joints or functional and dynamic joint movement should be trained with isolating extensions. n•tThe robotic system should be suitable to provide Kinesitherapy for orthopedic, neurological and cardiac patients of Adult and Pediatric age groups. n•tShould have dedicated exercise program for patients with severe paresis and muscle atrophy. n•tSystem should offer active exercises on all extension for Patients with innerved muscles but severe atrophy n•tThe device should offer exercises for dexterity training with dynamically changing resistance: concentric with elastic resistance and weight simulation.nn•tShould have inbuilt games and dynamic resistance exercises and to improve movement coordination. n•tShould have the facility to upgrade with games working with reactive electromyography n•tShould have tablet mounted on a retractable arm with height adjustable lifting column and preloaded Software application for quick setup and operationn•tShould be mounted on wheels with brakes for easy transportation and immobilization of the robot n•tEach extension should support a maximal applied weight of at least 30 kg. n•tThe rotation axis height of head should be at least 720-1070 mm and rotation limits should be at least 270 degree clockwise and anticlockwise with accuracy at least ±2 deg and Maximum torque: at least 60 Nm with measurement accuracy at least ±0.2 Nm.n•tShould be supplied with changeable extension parts for training and exercise of different joints including Shoulder, Elbow, Hip, Knee, Functional upper limbn•tShould include following extensions easy to mount in any orientation by plug and rotate method and automatic detection by the software: n•tElbow pronation/supination dynamic extension - n•tSteering wheel dynamic extension - n•tUpper limb universal extensionn•t Lower limb universal extension n•tThe system have facility for bioelectric measurements for diagnostic and reactive electromyography with clip electrode for EMG Measurement n•tSystem should have adjustable Range of motion, rotational torque and speed to suit different patient conditions. n•tThe software should provide summary and detailed extension specific information about all performed exercises after every training. n•tSystem Should allow following exercises and diagnosis :na.tContinuous passive motion nb.tProgressive Continuous Passive Motionnc.tSpring (Elastic) exercises:nd.tIsotonic exercises (weight lifting)ne.tDynamic reversalnf.tPrioperception – Hidden/Visibleng.tReactive electromyography trigger and hold nh.tReactive electromyography trigger and release ni.tEMG Biofeedback nj.tDiagnostic EMG nk.tThe software should have three primary game categoriesni.tOrthopedic – acting like concentric exercisesnii.tReactive EMG – acting like reactive electromyography trigger and holdniii.tIsometric EMG – acting like EMG biofeedbacknl.tAt least two games should be provided: Space shooter and Bubble.ni.tSpace shooter a game where the patients control the movement of a spaceship. nii.tBubble- a logic game where patients control the position of a bubble gun launching different color bubbles to form patterns. nThe system should meet the requirements of ISO60601-1-2 for electromagnetic compatibility, including immunity. Should have Class I protection against electric current, Medical device class: class IIa Applied part types: B, BF. ) 94 Lymphatic drainage system 95 BONE GROWTH STIMULATOR 96 Two Channel Combination Therapy With Dual Frequency Ultrasound-n(The Main unit should have:-n•t2 channels electrotherapy unit with 4 electrodes & 1 channel dual frequency ultrasound (1 or 3MHz).n•tColoured touch-screen large LCD for all parameters setting.n•tSimultaneous monitoring of 2 electrotherapy & one ultrasound channel with independent and combined n•tThe unit should operate on100 - 240 VAC 50 Hz.n•tWeight of equipment should be approximately 3.5 Kg for ease of moving.n•tIt should have body diagram with associated clinical programsn•tIt should also have port for attaching vacuum unit. n•tSafety class according to IEC 60601-1: Class 1, Type BFn•tUnit should be European CE approved.nElectrotherapy specifications:n•tDigital Timer: 1-60 minutesn•tIt should also have provision of I/T curve measurement n•tIt should also have setting range for AQ mode whenever vacuum unit is attached.n•tIt should have approximately 28 preset and 120 free program memories n•tVector Sweep 0°, 15°, 30° or 45°nIt should have following setting range:n-tParameter setting range for 2-Pole Interferential moden•tOutput mode: Constant, Sweepn-tParameter setting range for EMS moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten-tParameter setting range for Russian moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten•tCarrier frequency: 2.5 kHz n•tDuty: 10 to 100% (10% steps)n-tParameter setting range for Hi-Voltage moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont.,n•tSurge Alternaten•tPolarity: positive, negative, alternaten-tParameter setting range for TENS moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont., Surge Alternaten•tWaveform setting: Symmetrical waveform, asymmetrical waveformn•tPolarity: positive, negative, alternaten-tParameter setting range for Micro current moden•tPolarity: positive, negative, alternaten-tParameter setting range for Galvanic moden•tOutput mode: Continuous, Interruptedn•tPolarity: positive, negativen-tParameter setting range for Faradic moden•tPolarity: Positive, negativen•tFrequency: 20 to 250 Hz (10-Hz steps)n-tParameter setting range for Diadynamic moden•tOutput mode: DF, MF, CP, CP-ISO, LP, RSn•tPolarity: positive, negativen•tFrequency: 50 Hz or 100 HznUltrasound specifications:n•tBeam Non-uniformity Ratio (BNR) which prevents hot spots & tissue damage should be less than 5.0 and must be mentioned on the technical literature.n•tEffective Radiating Area (ERA) for large probe should be max. 5 cm2 & for small probe should be max. 1.0 cm2n•tFrequency: 1 & 3 MHz from same headn•tMode: Continuous & pulsed; duty cycle 5-50%n•tMax. Intensity: 3w/cm2in pulsed mode & 2 w/cm2 in continuous mode.n•tDigital Timer: 1-30 minutesn•tMemory capacity of: 18 preset & 10 free Programsn•tUS Probe should be IPX7 protected.nCombination Therapy:n•tIt should work in combination of Ultra sound and electrotherapy with dedicated single electrode of channel 2 as return electrode for electrotherapy and active as US probe.nIt should be supplied with following accessories:nUltrasound head large and small with probe holder, Electrode Cable – 2 pcs., Rubber Electrode, 60x50mm, 2pcs/pack – 2 Pack , Electrode Sponge A, 80x65mm, 2pcs/pack – 2 Pack, Strap (L), 80x1200mm – 2 pcs., Strap (S), 80x600mm – 2 pcs, Ultrasound gel (250 ml), Power Supply Cord (220-240V, Type F) – 1 pc., MCR (Micro current) Probe (2pcs/set to be used), HV/DC ProbenVacuum Unitn•tVacuum unit for enhancing the operability of electrotherapy units especially in abdominal & back regions. n•tThe unit should consist of 2 channel vacuum system for 4 vacuum electrodes.n•tIt should have blow out vacuum system which eliminates the need of water reservoir & reducing maintenance.n•tThe unit should have 2 vacuum modes: Continuous mode & int ermittent mode for patient comfort & skin massage.n•tThe unit should have vacuum strength up to 100 mm Hgn•tThe unit should operate on 100 - 240 VAC with 50 Hz frequency power supplyn•tMain unit should be supplied with:- 4 rubber electrode, 4 electrode sponge, 2 electrode cable, 4 straps (2 large and 2 small), 4 Vacuum electrode, 4 Electrode sponges for Vacuum electrode, Power supply cord.) 97 AUDIOLOGY & SPEECH THERAPY UNIT 98 Single Portable Unit -Pure tone Audiometer with facilities of free field audiometry & speech audiometry with-nFrequency range for AC- 125Hz to 8000HznFrequency range for BC- 250Hz to 6000HznDynamic range (1000Hz)- -10dB HL to 120 dB HLnShould be European CE/ANSI/ISI approved 99 Non-sedated diagnostic BERA with 2 channel and VEMP, ABR & SSR facilities and computer accessibility through USB portal 100 Video Oto-scope with computer accessibility 101 Acoustic booth 15’x12’x 7’ with inner partition, double door, magnetic seal, silenced ventilation 102 Visi-pitch with all accessories 103 Bio feedback system for stammering therapy with all accessories 104 Speech therapy materials (Local purchase) 105 Mattress 6’ x 6’ 106 Group Hearing aid with loop induction system 107 Mattress 6’ x 6’ 108 PSYCHOLOGY UNIT 109 Binet Kamat Intelligence Test (BKT) 110 Intelligence Scale for Indian Children 111 Bhatia Battery of Performance Intelligence Test 112 Diagnostic Test of Learning Disability (DTLD) 113 Diagnostic Test of Reading Disorder (DTRD) 114 Behavioural Checklist for Screening the Learning Disabled (BCSLD) 115 Swarup-Mehta Test of Thinking Strategies (TTS) 116 Thematic Apperception Test (TAT) 117 Non-Verbal Group Intelligence Test (NVGIT) 118 Rorschach Ink Blot Test 119 (DAP:IQ)Draw-A-person Intellectual Ability Test for Children Adolescents and Adults 120 Conduct Disorder Scale (CDS) 121 Revised Hamilton Rating Scale for Depression (RHRSD) 122 Indian Adaptation of the Multidimensional 123 Aptitude Battery - MAB – II 124 Child Sexual Behaviour Inventory (CSBI) 125 Teachers Job Satisfaction Scale 126 ADHD Symptoms Rating Scale (ADHD-SRS) 127 CHILD & ADOLESCENT SYMPTOM INVENTORY-4R (CASI-4R) 128 Multiscore Depression Inventory for Children (MDI-C) 129 Stop Watch [Timer] Racer Electronics [SWE] 130 Gifted and Talented Evaluation Scales 131 Test of Memory and Learning - Second Ed. (TOMAL-2) 132 Early Childhood Inventory-4 (ECI-4) 133 Slosson Full-Range Intelligence Test (S-FRIT) 134 Bender Visual-Motor Gestalt Test - Second Edition (BGT - II) 135 Stroop Color and Word Test (Children) 136 Personality Inventory For Children 2nd Ed. 137 Seguin Form Board Test with Manual & Answer Sheets. 138 Childhood Autism Rating Scale - Second Edition (CARS 2) 139 Children’s Color Trails Test (CCTT) 140 Intelligence Test for Adult 141 State-Trait Anger Expression Inventory-2™(STAXI-2) 142 Multi-dimensional Anxiety Questionnaire (MAQ) 143 Substance Abuse Subtle Screening Inventory (SASSI-3) 144 Suicidal Ideation Questionnaire (SIQ) 145 Relaxation Chair 146 ISAA & INCLEAN TOOLS for ASD 147 BLOOD DISORDER DISABILITY UNIT 148 Thalassemia Rapid test 149 Blood Gas Analyzer 150 Methylene Blue Chemical – 151 Urine Analyzer– 152 VISUAL UNIT 153 Hand held slit lamp 154 Direct Ophthalmoscope 2.8 v 155 Trial set power cotted/Stereo Acuity Test material 156 Trial frame for both adult and paediatric 157 Distance vision testing drum remote control motorised movement 158 VS-V Universal Vision Screener (for school going children also) 159 Tele Binocular Equipment 160 LED Vision Chart 161 Snellen Chart/Eye Testing Drum 162 Automatic Matrix Auto Refractometer R-20 for eye Examination 163 Near Vision Drum 164 Acuity Digital Vision Tester 165 Keratometer&Keratoscope tools 166 Brallier (Braille Type Writer) 167 Orbit Reader (Braille Embossed Reader) 168 Pen Scanner 169 Magnifiers for low vision (NIEPVD) 170 MAGIC software for low vision 171 Electronic Mobility Cane/White Cane 172 TEACHING LEARNING MATERIAL-n(N.B.-All TLM should be made of Nontoxic, Hygienic material ensuring safety of children. Toys should not have any sharp edges to prevent any possible injury to children.) 173 Rattle toys-(Age Group 0 to 3 Years) 174 Fruit Tray-(Age Group 0 to 3 Years) 175 Parts of body-(Age Group 0 to 3 Years) 176 Building Towers-(Age Group 0 to 3 Years) 177 Different Balls-(Age Group 0 to 3 Years) 178 Zig saw Puzzle-(Age Group 0 to 3 Years) 179 Dolls-(Age Group 0 to 3 Years) 180 Wooden Blocks-(Age Group 0 to 3 Years) 181 Drum-(Age Group 0 to 3 Years) 182 English Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 183 Flash Card of Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 184 Eye hand coordination (Beads)- (Age Group 3 To 6 Yrs.) 185 Abacus– (Age Group 3 To 6 Yrs.) 186 Shape, Size, Colour, Concept &. puzzle box – (Age Group 3 To 6 Yrs.) 187 Zig saw Puzzle– (Age Group 3 To 6 Yrs.) 188 Colour book with crayon holder– (Age Group 3 To 6 Yrs.) 189 Easel and Board– (Age Group 3 To 6 Yrs.) 190 Magic Slate– (Age Group 3 To 6 Yrs.) 191 Blowing toys– (Age Group 3 To 6 Yrs.) 192 Picture and Ward Cards - (Age Group 7 To 11 Yrs.) 193 Assembly Kit- (Age Group 7 To 11 Yrs.) 194 Number Cards- (Age Group 7 To 11 Yrs.) 195 Zig Shaw Puzzle - (Age Group 7 To 11 Yrs.) 196 Telling Time Kit - (Age Group 7 To 11 Yrs.) 197 Count and Match - (Age Group 7 To 11 Yrs.) 198 Puzzle body parts - (Age Group 7 To 11 Yrs.) 199 Coloring Books with Crayons– (Age Group 7 To 11 Yrs.) 200 Beads– (Age Group 7 To 11 Yrs.) 201 Magic Slate– (Age Group 7 To 11 Yrs.) 202 Duplicate Currency– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 203 General Knowledge Flash Cards– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 204 Mobile Phone– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 205 Calculator– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 206 Digital Watch– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 207 Number Cubes– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 208 Multiplication Tactile Board– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 209 Worksheet, Pen & Duster, Story Books– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 210 Coloring Books with Crayons– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 211 Kitchen Set– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 212 SPORTS MATERIALS 213 Recreational Gaming Play Station 214 Eye Convalescence System –with Bed 215 EMG Biofeedback With Pelvic Floor Rehabilitation For Urinary Incontinence
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
43.
Public Administrative Department #10546981 Price Bid
Tender For Provision For Installation Of Cctv Cameras In Record Room At Zonal Building Under Shahdra South Zone.; 1 SITC of 4MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum:30mOperating Temperature: -20 to 55 deg CentWeatherproof Standard: IP66 or better **Safety standard: UL 2 SITC of 4MP varifocal lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 50 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 3 SITC of 16 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :80Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of full HD LED Monitor, 42 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.Complete as required. 5 SITC of 8 TB surveillance HDD 6 Supplying and drawing of UTP 4 pair CAT 6LANE ofCable in the existing surface/ recessed steel/PVC conduit as required.(a) 1 run of cable. 7 (b) 2 run of cable. 8 (c) 3 nrun of cable. 9 Supply and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/recessed steel/PVC conduit as required. (a)2x2.5 sqmm 10 SITC of 16 port Giga PoE switch, 16(PoE 10/100) + 2(10/100/1000) port long distance switch 11 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 3 KVA 12 Supplying and fixing of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25mm 13 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8U 14 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
44.
Public Administrative Department #10546972 Price Bid
Tender For Provision Of Cctv System At M&Cw Centre Of Vishwakarma Park Under Shahdra South Zone.; 1 SITC of 4MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum:30mOperating Temperature: -20 to 55 deg CentWeatherproof Standard: IP66 or better **Safety standard: UL 2 SITC of 4MP varifocal lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 50 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 3 SITC of 8 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :80Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of full HD LED Monitor,42 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.complete as required. 5 SITC of 6 TB surveillance HDD 6 Supplying and drawing of UTP 4 pair CAT 6LANE ofCable in the existing surface/ recessed steel/PVC conduit as required. (a) 1 run of cable. 7 Supply and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/recessed steel/PVC conduit as required. (a)2x2.5 sqmm 8 SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 9 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 3 KVA 10 Supplying and fixing of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25mm 11 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 12 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
48.
Petroleum and Natural Gas #10505803 Price Bid
Limited Tender Enquiry For Supply And Installation Of Electromagnetic Flow Meters At Hbl Lauriya Plant. Limited Tender Enquiry For Supply And Installation Of Electromagnetic Flow Meters At Hbl Lauriya Plant. , Supply, Transportation, Loading, Unloading, Erection And Commissioning, Successful Trial & Testing Of Electromagnetic Flowmeters Make Krohne Marshall / E & H For Ethanol Plant At Hbl Lauriya. Details Of Items As Mentioned Below. , Magnetic Flow Meter: Model : 5Wbb65-Aadaebjaodud210aa1 + Aa Make E&H / Model : 5Wbb65-Aadaebjaodud210aa1+Aa / Optiflux 2000 + Ifc100 Make Krohne Marshall, Meter Size: Dn65, Transmitter + Sensor : Non Hazardous Area, Power Supply : 100-230 Vac, Output : Input: 4-20Ma Hart, Pulse / Freq. / Switch, Display : Operation: Lcd, 2.40; Smart Blue App, Housing: Compact, Alu, Coated, Electrical Connection: Thread Npt 1 / 2, Liner: Polyurethane, Process Connection: Pn10, Carbon Steel, Lap Joint Flange, Stamped Plate En10. , Magnetic Flow Meter: Model : 5Wbb80-Aadaebja0dqd210aa1+Aa Make E & H Model : Optiflux 4000 +Ifc100, Make Krohne Marshall, Meter Size : Dn80, Transmitter + Sensor : Non-Hazardous Area, Power Supply: 100-230Vac, Output : Input: 4-20Ma Hart, Pulse / Freq. / Switch Display : Operation : Lcd, 2.40; Smart Blue App, Housing : Compact, Alu, Coated, Electrical Connection : Thread Npt1 / 2, Liner : Ptfe 90°C, Process Connection: Pn10, Carbon Steel, Lap Joint Flange, Stamped Plate En.1092-1, Calibration Flow: 0.5%. , Vortex Flow Meter: Model No 7F2c25-Bbaccaaaaaaaaska1+Aa Make E&H / Model Optiswirl - 4200 : Make Krohne Marshall Meter Size Dn15, :Atex Ii1 / 2G Ex Ia Iic, Output ; Input : 4-20Ma Hart , Display : Operation : Sd02 4-Line ; Push Buttons + Data Backup Function, Housing: Gt20 Dual Compartment, Alu. Coated, Compact Electrical Connection: Gland M20, Process Connection : Cl.150 Rf Sch.40, Flange Asme B16.5 Calibration Flow: 0.75% Volume 3 Point. => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
49.
Educational and Research Institute #10502902 Price Bid
Supply Of Library Books , Library Books , Introduction To Database Management System P.K. Yadav , Database Management Systemp.K. Yadav , Concepts Of Database System P.K. Yadav , Software Project Managementrajiv Chopra , Software Testing Rajiv Chopra , Software Testing And Quality Assurance Rajiv Chopra , An Integrated Approach To Software Engineering Rajiv Chopra , Internet Of Things ( Iot ) Rajiv Chopra , Object Oriented Software Engineeringrajiv Chopra , Introduction To Microprocessor Rajiv Chopra , Requrements And Estimation Techniques Rajiv Chopra , Fundamentals Of Computing Rajiv Chopra & Rishbh Anand , An Introduction To Automata Theory & Formal Languages Adesh K. Pandey , Introd. To Automata Theory & Formal Lang.Adesh K. Pandey , Fundamentals Of Compiler Designadesh K. Pandey , Concepts Of Complier Designadesh K. Pandey , Concepts Of E-Commerceadesh K. Pandey , Internet Fundamentalsadesh K. Pandey , Network Security & Administrationadesh K. Pandey , Internet & Web Designingadesh K. Pandey &Er.Neha Dutta , Introduction To E-Commerce & Erpadesh K. Pandey , A Textbook Of Compiler Designadesh K. Pandey , Elements Of Compiler Designadesh K. Pandey , Theory Of Automata And Computationadesh K. Pandey , Theory Of Computationadesh K. Pandey , Fundamentals Of Electronics Commerce Adesh K. Pandey , Internet Programming Using Javapandey & Pandey , Fundamentals Of Computer Programming In Cs.K.Jha , System Analysis & Designs.K.Jha , Programming In Cs.K.Jha , Pc Organization S.K.Chauhan , Pc Upgrading Maintenance & Trouble Shooting Guide , Neural Network & Fuzzy Logicvinoth Kumar And R.Saravana Kr. , Soft Computingk.Vinoth Kumar , Fundamentals Of Soft Computingk.Vinoth Kumar , Computer Concepts & Programming In Camit Kumar Mishra , Basic Computer Engineeringamit Kumar Mishra , Introduction To Computer Systemamit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , A Textbook Of Computer Architecture Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer System And Programming In C Amit Kumar Mishra , Computer Architecture & Organizationamit Kumar Mishra , Information Security And Cyber Laws Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer Architecture Amit Kumar Mishra , Computer Programming Amit Kumar Mishra , Fundamentals Of Computer And Programming Amit Kumar Mishra , Software Engineeringbali And Bali , Fundamentals Of Software Engineeringbali And Bali , Thinking In C++ Rajesh Kocher & Sunil K. Pandey , Learn Autocadrajesh Kocher & Sunil K. Pandey , Fundamentals Of Computer Programming And Itsunil K. Pandey& V.K. Jain , Object Oriented Programing With C ++ Sunil K. Pandey& Rajesh Kochher , Programming Language Nitin Upadhyay , The Design & Analysis Of Algorithmsnitin Upadhyay , Data Structures And Algorithms Using C Nitin Upadhyay , Question Bank In Computer Sciencenitin Upadhyay, Pankaj Sharma , Computer Networks Dr. Sanjay Sharma , Elements Of Computer Networks Dr. Sanjay Sharma , Computer Networks Dr. Sanjay Sharma , A Course In Computer Networksdr. Sanjay Sharma , Introduction To Computer Networks Dr. Sanjay Sharma , Computer Networks-I Dr. Sanjay Sharma , Advanced Computer Networksdr. Sanjay Sharma , Computer Networks-Ii Dr. Sanjay Sharma , Principles Of Computer Networks Dr. Sanjay Sharma , Digital Logic Design Dr. Sanjay Sharma , A Textbook Of Computer Network Dr. Sanjay Sharma , Fundamentals Of Computer Network Dr. Sanjay Sharma , Introduction To Web Technologypankaj Sharma , Fundamentals Of Web Technologypankaj Sharma , Working With Artificial Intelligencepankaj Sharma , Web Engineering Pankaj Sharma , Manet And High Speed Networkspankaj Sharma , Computer Organization Pankaj Sharma , Computer Architecture & Organizationpankaj Sharma , System Programmingpankaj Sharma , Expert System Pankaj Sharma , Information Security & Cyber Lawspankaj Sharma , System Programming & System Admin. Pankaj Sharma , Rapid Application Devlop.Using Visual Basic & Visual C++Pankaj Sharma , Parallel Algorithms Pankaj Sharma , Pattern Recognitionpankaj Sharma , Web Developmentpankaj Sharma , Information Storage & Managementpankaj Sharma , Web Engineering Pankaj Sharma , System Administration Pankaj Sharma , Information Security Pankaj Sharma , Cloud Computing Pankaj Sharma , Introduction To Web Engineering Pankaj Sharma , Web Administration Pankaj Sharma , Dot Net Framework With C# Programming Dr. Lalit Arora , Object Oriented System With C++ Dr. Lalit Arora , Object Oriented System With Javadr. Lalit Arora , Internet & Javadr. Lalit Arora , C# Using .Net Frameworkdr. Lalit Arora , Java Programming & Web Site Designdr. Lalit Arora , Object Oriented Techniques Java Dr. Lalit Arora , Object Oriented Programing Using C ++Dr. Lalit Arora , It Skills And Technology Dr. Lalit Arora , Concept Of Programming And Oopsdr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Organization & Architecture Dr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Graphicsudit Agarwal , Introduction To Computer Graphicsudit Agarwal , Data Structures Using C Udit Agarwal , Data Structures Udit Agarwal , Software Engineeringudit Agarwal , Distributed Systems Udit Agarwal , Distributed Computing Udit Agarwal , Data Mining And Data Warehousingudit Agarwal , Computer Graphics And Multimedia Udit Agarwal , Programming For Problem Solving Udit Agarwal , Operating Systemvijay Shukla , Multimedia System, Technology & Communication Sujata Pandey , Data Mining & Data Ware Housing , Network Programmingkadambri Agarwal , Programming Languages Kadambri Agarwal , Network Technologykadambri Agarwal , System Network Administration Kadambri Agarwal , Graph Theoryk.Patrai , Discrete Structures & Graph Theoryk.Patrai , Mobile Computingvishnu Sharma , Advances Mobile Computingvishnu Sharma , A Course In Electrical Technologyj.B Gupta , A Course In Electrical Technology-Ij.B Gupta , A Course In Electrical Technology-Iij.B Gupta , A Course In Electrical Technology-Iiij.B Gupta , Generation & Economic Considerationsj.B Gupta , A Course In Electrical Powerj.B Gupta , A Course In Power Systems J.B Gupta , Theory & Performance Of Electrical Machinej.B Gupta , Utilization Of Electric Power & Electric Tractionj.B Gupta , Utilization Of Electrical Energy And Traction J.B.Gupta, R. Manglik, R. Manglik , Switchgear & Protectionj.B Gupta , A Course In Electrical Installation Estimating & Costingj.B Gupta , Fundamentals Of Electrical & Electronics Engineering J.B Gupta , Transmission & Distribution Of Electrical Powerj.B Gupta , Basic Electrical Engineeringj.B Gupta , Basic Electricity J.B Gupta , Electrical Measurements & Measuring Instrumentsj.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machine - Iij.B Gupta , An Integrated Course In Electrical Engineering J.B Gupta , Explanation / Solutions To An Integrated Course In Electrical Engineering J.B Gupta , An Integrated Course In Electrical Engineering Volume I J.B Gupta , An Integrated Course In Electrical Engineering Volume Ii J.B Gupta , Question Bank In Electrical Engineeringj.B Gupta , Question Bank In Electrical Engineering Volume I J.B Gupta , Question Bank In Electrical Engineering Volume Ii J.B Gupta , A Text Book Of Electrical Engineeringj.B Gupta , Electrical Science J.B Gupta , Electromechanical Energy Conversionj.B Gupta , Electromechanical Energy Conversion- Ij.B Gupta , Electromechanical Energy Conversion- Iij.B Gupta , Electrical Machines ( Ac, Dc Machine ) J.B Gupta , A Text Book Of Electrical Technologyj.B Gupta , Electrical Machines & Automatic Controlj.B Gupta & Hasan , Elements Of Power Systems J.B Gupta , Power System Analysis J.B Gupta , Fundamentals Of Switchgear & Protectionj.B Gupta , Electrical Engineering Materials & Semiconductor Devices J.B Gupta , Basic Electrical & Electronics Engineering J.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machines-Ii J.B Gupta , Electrical Technologyj.B Gupta , Basic Electrical Engineeringj.B Gupta , Fundamentals Of Electrical Engineering J.B Gupta , Elements Of Electrical Engineering J.B Gupta , Basic Electrical Engineering J.B Gupta , A Textbook Of Electrical Science J.B Gupta , A Textbook Of Electrical Engineering Rajeev Manglik , Power System & Protectionn.K.Datta , Theory & Performance Of Electrical Machine Design Dr. N.K.Datta , Principles Of Electrical Machine Designr.K. Agarwal , Electrical Engineering Materialsrakesh Dogra , Electrical Engineering Drawing-Isurjit Singh , Electrical Engineering Drawing-Iisurjit Singh , Electrical Measurements & Measuring Instrumentsm.L.Anand , Basic Electrical Engineeringtarlok Singh , Installation Commissioning & Maintain. Of Elect. Equip.Tarlok Singh , Electrical Measurement & Measuring Instrumentstarlok Singh , Elements Of Electrical & Electronics Engineering Tarlok Singh , Utilization Of Electric Energytarlok Singh , Electrical Machine-Itarlok Singh , Electrical Machine-Iitarlok Singh , Electrical Power-Iitarlok Singh , Fundamentals Of Electrical Engineering Tarlok Singh , Electrical Science Tarlok Singh , Transmission & Distributiontarlok Singh , Modern Electric Traction Tarlok Singh , Energy Managementdr. Sanjeev Singh, Umesh Rathore , Basic Instrumentation System & Programmable Logic Controllerumesh Rathore , Industrial Instrumentationumesh Rathore , Programmable Logic Controller And Microcontrollers Umesh Rathore , A Textbook Of Electrical Workshop Practices Umesh Rathore, Naresh Kumar Sharma , A Textbook Of Energy Science & Engineering Umesh Rathore , Fundamentals Of Managementdr. R.C.Bhatia , Sub-Station Engineering Design, Concepts & Computer Applications Er. R.S.Dahiya , An Introduction To Electric Traction Sachidananda Mallik & Rupali G. Nazar , Fundamentals Of Managementrenu Rana , Special Electrical Machines Simmi P Burman , High Voltage Engineering Simmi P Burman & Nikita Gupta , Electrical Engineering Laboratory Practice P. Tiwari & S. Sairola , Ehv-Ac, Hvdc Transmission And Distribution Engineering Sanjay Kumar Sharma , Basic System Analysissyed Hasan Saeed & Faizan Arif Khan , Power Quality Simmi P. Burman & Bipin Singh , Scada And Energy Management System Er. Tanuj Kumar Bisht , Computer Aided Design Of Electrical Machines V.K. Maurya, Ritu Raj Jallan, Shasya Shukla , A Textbook Of Power System Operation And Control K. Nisha , Electromagnetic Field Theory Syed Hasan Saeed & Faizan Arif Khan , Installation Maintenance And Repair Of Electrical Machines And Equipments Madhvi Gupta , Electrical Engnineering Design, Drawing & Estimation Madhvi Gupta, Ankit Agarwal , Control Systems S.P. Meher , Fundamentals Of Smart Grid Technology Bharat Modi, Anu Prakash & Yogesh Kumar , Electric Vehicle Dr. Nitesh Tiwari , Ssc-Je-Question Bank In Electrical Engineering J.B.Gupta , Ace Academy Gate 2024 Ace Publication , Gate / Ese / Psus Electrical Handbook Ace Publication , Ace Academy Ese Vol 1And Vol 2 Ace Publication , Yct Electrical Engineering Je-Vol And Vol 2 Yct Publications , Yct Electrical Engineering Ae-Vol And Vol 2 Yct Publications , Basic Electrical Engineering Vol 1S Chand Publication, B L Theraja , Ac & Dc Machine Vol 2 S Chand Publication, B L Theraja , Transmission And Distribution Utilisation S Chand Publication, B L Theraja , Electronics Devices And Circuits S Chand Publication, B L Theraja , Power Electronics Khanna Publications, Dr. Ps Bhimbra , Fundamentals Of Electrical Circuits Mc Graw Hill, Charles K.Alexander , Objective Electrical Technology V.K.Mehta, Rohit Mehta , Principles Of Power System V.K.Mehta, Rohit Mehta , Principles Of Electrical Machines V.K.Mehta, Rohit Mehta , Control Of Machines New Age International , Sk Bhattacharya , Linear Integrated Circuits New Age International , Sk Bhattacharya , Programmable Logic Controllerpearson, John.R.Hackworth , Principles Of Electromagnetics Oxford, Sadiku & Kulkarni , A Course In Electrical & Electronics Measurements And Instrumentation Dhanpat Raj & Co , A K Sawhney , Fundamentals Of Digital Circuits Phi, A.Anand Kumar , Power Electronics Devices Circuits And Applicationpearson, Muhammad H. Rashid , Electrical Power System C.L.Wadhwa, New Age International , Modern Power System Analysis Mc Graw Hill, D.P.Kothari , Electrical Machinery Khanna Publications, Dr. Ps Bhimbra , Generalized Theory Of Electrical Machines Khanna Publications, Dr. Ps Bhimbra , Electronics Devices And Circuits S.Salivahanan, Mc Graw Hill , Micro Controller Principles And Applications Ajit Pal, Eastern Economy Edition , Power Plant Engineering Mc Graw Hill, P K Nag , Power System Engineering Lp, R.K.Rajput , Non Conventional Energy G D Rai, Khanna Publication , Basic Electrical And Electronics Engineering Mc Graw Hill, D.P.Kothari , Repair And Maintenance Bpb Publications, Shashi Bhushan Sinha , Electrical Applications Haynes , Electronic Devices And Circuitsj.B.Gupta , Basic Electrical And Electronics Engineeringj.B.Gupta , Linear Integrated Circuitsj.B.Gupta , Fundamentals Of Analog Electronicsj.B.Gupta , Basic Electronics J.B.Gupta , Electrical & Electronics Engineering J.B.Gupta , A Textbook Of Basic Electronics J.B.Gupta, Rajeev Manglik, Rohit Manglik , Analog Devices And Circuits J.B.Gupta , Fundamentals Of Electronics Devices & Circuits J.B.Gupta , Electronic Devices & Circuits Dr. Sanjay Sharma , Analog & Digital Electronicsdr. Sanjay Sharma , Signal & Systemsdr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Electronics Circuits Dr. Sanjay Sharma , Digital Electronics Dr. Sanjay Sharma , Digital Communications Dr. Sanjay Sharma , Fundamentals Of Electronic Devicesdr. Sanjay Sharma , Digital Communication Dr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Principle Of Digital Signal Processingdr. Sanjay Sharma , Analog & Digital Communication Dr. Sanjay Sharma , Signal & System Dr. Sanjay Sharma , Fundamentals Of Communication Engineering Dr. Sanjay Sharma , Communication Engineeringdr. Sanjay Sharma , Digital Electronics And Logic Design Dr. Sanjay Sharma , Digital Circuits & Systems Dr. Sanjay Sharma , Wireless Communication Systems Dr. Sanjay Sharma , Electronic Circuits Dr. Sanjay Sharma , Digital Electronics & Design Aspects Dr. Sanjay Sharma , Electronic Devices Dr. Sanjay Sharma , Signals & Systems Dr. Sanjay Sharma , Digital Design Dr. Sanjay Sharma , Analog And Digital Electronics Dr. Sanjay Sharma , A Textbook Of Electronics Engineering Dr. Sanjay Sharma , Fundamentals Of Digital Electronics Dr. Sanjay Sharma , Fundamentals Of Digital Image Processing Dr. Sanjay Sharma , Digital Image Processing Dr. Sanjay Sharma , Wireless Communication System Dr. Sanjay Sharma , Mobile Computing Dr. Sanjay Sharma , Switching Theory And Logic Design Dr. Sanjay Sharma , Essentials Of Computer Networks Dr. Sanjay Sharma , Data And Computer Communications Dr. Sanjay Sharma , Fundamentals Of Switching Theory & Logic Design Dr. Sanjay Sharma , Essentials Of Analog Communication Dr. Sanjay Sharma , Data Communication And Computer Networks Dr. Sanjay Sharma , A Textbook Of Data Communication And Networks Dr. Sanjay Sharma , Essentials Of Wireless Communication Dr. Sanjay Sharma , Fundamentals Of Electronics Engineering Dr. Sanjay Sharma , Wireless Communicationsdr. Sanjay Sharma , Electronic Devices & Circuits Dr. Sanjay Sharma , Fundamentals Of Digital Signal Processing Dr. Sanjay Sharma , Fundamentals Of Analog Communication Dr. Sanjay Sharma , A Textbook Of Signals & Systems Dr. Sanjay Sharma , Solid State Devices & Circuits Dr. Sanjay Sharma , Electronics-I Dr. Sanjay Sharma , Signal Processing And Linear Systems Dr. Sanjay Sharma , Emerging Domain In Electronics Engineering Dr. Sanjay Sharma , Circuits & Systemsk.M.Soni , Circuit Analysis And Synthesis K.M.Soni , Advanced Control Systemsk.M.Soni , Network Analysis & Systhesisk.M.Soni , Network Analysisk.M.Soni , Network Theory K.M.Soni , Fundamentals Of Network Analysis & Synthesis K.M.Soni , Basic System Analysisk.M.Soni , Signals And Systems K.M.Soni , Digital Electronicsb.R.Gupta And V.Singhal , Consumer Electronicsb.R.Gupta , Power Electronicsb.R.Gupta And V.Singhal , Introduction To Electric Drivesb.R.Gupta And V.Singhal , Question Bank Electronics & Communicationengineeringb.R.Gupta And V.Singhal , Fundamentals Of Electric Drives And Control B.R.Gupta And V.Singhal , Industrial Electronics & Instrumentationsunil Kumar , Optical Fiber Communicationsapna Katiyar , Satellite Communicationsapna Katiyar , Advanced Communication Systemsapna Katiyar , Electronic Switchingsapna Katiyar , Introduction To Optical Communicationsapna Katiyar , Telecommunication Networkssapna Katiyar , Fundamentals Of Optical Fiber Communicationsapna Katiyar , A Textbook Of Optical Fiber Communication Systems Sapna Katiyar , Introduction To Satellite Communcation Sapna Katiyar , Tv And Satellite Communications Sapna Katiyar , Vlsi ( Technology, Design & Basics Of Microelectronics ) Sapna Katiyar , 8051 Microcontroller & Embedded Systemsampath K. Venkatesh , Digital Circuit System Using Vhdlneelu Chaudhary And Shipra Gupta , Digital Logic & Design Pratima Manhas And Shaveta Thakral , Digital Electronicspratima Manhas And Shaveta Thakral , Vlsi Design Pratima Manhas & Shaveta Thakral , Introduction To Microprocessors & Interfacingaashutosh Gupta , Electromagnetic Fields & Wavesr.Gowri , Wireless Communicationaman Kundra And Amrita Sandhu , Trouble Shooting & Maintenance Of Elect. Equipmentsk.Sudeep Singh , Fundamentals Of Television & Radar Engineering K.K Sharma , Fundamentals Of Radar, Sonar & Navigation Engineering K.K Sharma , Fundamentals Of Data Communicationk.K Sharma , Digital & Analog Communicationk.K Sharma , Microwave & Radar Engineeringk.K Sharma , Antenna & Wave Propagation A.K.Gautam , Principle Of Communication Engineering A.K.Gautam , Communication System-Ia.K.Gautam , Microwave Engineering A.K.Gautam , Control System Hasan Saeed , Digital & Analog Communicationbrijesh Verma , Mobile Communicationbrijesh Verma , Telemetry & Data Transmissionr.N.Baral , Electronics Devices & Circuits-I M.L.Anand , Bio-Medical Signal Processing Rakesh Kumar , Medical Electronics O.N. Pandey & Rakesh Kr. , Instrumentation And Process Control O.N. Pandey , Electromagnetic Field Theory Parul Dawar , Digital Circuit And Systems Shipra Gupta , Vlsi Designc.P Verma , Introduction To Vlsi Circuits & Systems Deepak Garg , Vlsi Technology Deepak Garg , Fundamentals Of Vlsi Design Deepak Garg , Basics Of Vlsi Design With Vhdl Deepak Garg , Microprocessor & Interfacingn. Marriwala , Embedded System Design N. Marriwala & Ritu Khullar , Fundamentals Of Radar & Navigation Sachin Gupta , Optical Communication Sachin Gupta , Microwave And Radar Engineeringravi Garg & Ankaj Gupta , Antenna And Wave Propagation Prashant Pandey , Digital Electronics Preeti Sehrawat , Electronic Circuits M. Elangovan , Electromagnetics And Antennas H. Singh , Optoelectronics & Optical Communication Satyajit Das , Control Systems Engineering Dr. S. Panda, S. Padhy & S.R. Das , Microcontroller And Embedded Systems Ankaj Gupta , Microprocessors And Microcontrollers Ankaj Gupta , Fundamentals Of Microprocessors And Embedded Systems Ankaj Gupta , Microprocessors Shweta Goyal & Swati Gargust , Industrial Electronics And Control Of Drives Shweta Goyal & Swati Gargust , Engineering Economics And Industrial Management Dr. R.K. Singal & Er. Rishi Singal , Microwave & Radar Engineering Er. Rajesh Dhiman , Embedded Systems Anurag Arora , Wireless Sensor Networks Sunil Gupta & Dr. Harsh K. Verma , Probability, Random Variables And Stochastic Methods Himanshu Chaurasiya & Dr. K.M. Soni , Relational Database Management System Pooja Sharma & D.S. Sehrawat , Semiconductor Devices And Circuits C.S. Murlidharan Sharma , Industrial Power Electronics Partha K. Ganguly , An Insight To Matlab & Simulink Dr. Shailender Gupta & Bharat Bhushan , Fundamentals Of Optical Communication & Networks Shila Ghosh, Somali Sikder , Digital Image Processing Ketki Kshirsagar, Rajeshree Shinde , Embedded System & Microcontroller Manish Verma & K.B. Singh , Electronic Design Automation & Logic Synthesissarita Chauhan , Artificial Intelligence For Engineers Malvika Gupta, Medha Malik , Principles Of Electronics Dr. S.K. Bhattacharya , Machine Learning Dr. Himanshu Sharma , Strength Of Materials R.S.Khurmi S.Chand & Company Ltd, New Delhi , Strength Of Materials S.Ramamirtham Dhanpat Rai , Engineering Mechanics R K Bansal Laxmi Publications Pvt.Ltd. , Building Materials P.C.Varghese Prentice-Hall Of India ( P ) Ltd., I Edition , Building Construction Dr. B.C. Punmia Laxmi Publications ( P ) Ltd New Delhi. , Building Construction S.C.Rangwala Charotar Publishing House, Vii Edition , Surveying Volume I Punmia.B.C. Ashok K.Jain & Arun K. Jain Lami Publications Private Limited, 16Th Edition , Surveying Volume Ii & Iii Punmia.B.C, Ashok Jain & Arun K. Jain Lami, Publications Private Limited., 15 Th Edition, , Fundamentals Of Surveying S. K. Roy Phi Learning Private Limited , Building Planning And Drawing Dr.N.Kumaraswamy Charotor Publishing House , Building Planning And Construction G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , A Guide To Civil Engineering Drawing V.R.Thothathri , Theory Of Structures S. Ramamrutham Dhanpat Rai Publications, New Delhi , Theory Of Structures B.C. Punmia, Ashok Jain & Arun Jain Laxmi Publications , Analysis Of Structures V.N. Vazirani & M.M. Ratwani , Fluid Mechanics R.K. Bansal Lakshmi Publications , Hydraulics, Fluid Mechanics And Hydraulics Machines S. Ramamirtham Dhanpat Rai & Sons, New Delhi , Hydraulics, Fluid Mechanics And Hydraulics Machines K.R. Arora Standard Publishers & Distributors, New Delhi , Highway Engineering S.K.Khanna And C.E.G Justo Nem Chand And Bros, Roorkee. , Highway Engineering Rangwala Charotor Publishing House Pvt. Ltd , A Text Book Of Transportation Engineering S P Chandola S Chand & Company Ltd , Bridge Engineering Rangawala Charotor Publishing House , Reinforced Concrete Design N Krishnaraju New Age International Publications, 2012 , Is 456-2000 , Steel Structures Hand Book Sp16 , Limit State Design Of Reinforced Concrete B C Punmia Laxmi Publications, 2007 , Design Of R C C And Structural Elements ( Rcc Vol I ) S S Bhavikatti, New Age International Publications, 2011 , Environmental Engineering B C Punmia Lami Publications, 2010 , Waste Water Engineering B C Punmia , Laxmi Publications, 2010 , Environmental Engineering A.Kamala, D.L.Kanthraotata Mcgraw Hill Publishing Company Ltd., New Delhi , Concrete Technologym.S. Shetty S.Chand & Company Pvt. Ltd. New Delhi. , Soil Mechanics And Foundation Engineering B C Punmia Laxmi Publications ( P ) Ltd., 2005 , Civil Engineering Drawings.C. Rangwala Charotor Publishing House , Construction Management Sanga Reddy. S Kumaran Publications, Coimbatore , Steel Structures Dr.Subramaniam , Town Planning S.C. Rangwala , Principles And Practice Of Town And Country Planninglewis B. Keeble Estates Gazette, University Of Michigan, 2010 , Estimating & Costing L.N.Dutta Dhanpat Rai & Sons , Estimating & Costingrangawala , Charotor Publishing , Quantity Surveying & Valuation N.A.Shaw Khanna Publishers; , Civil Engineering Competitionsbooks R.Agor Khanna Publishers; , Civil Engineering ( Objective Type ) P Jaya Rami Reddy , Laxmi Publications , Reinforced Concrete Design S.Unnikrishna Pilla & Devadas Menon, Mc Graw Hill Publications , Limit State Design Of Steel Structures S K Duggal , Mc Graw Hill Publications , Basic And Applied Soil Mechanics , Gopal Ranjan & A S R Rao, New Age International Publications , Fluid Mechanics And Fluid Power Engineering Dr. D.S Kumar , Basics Of Mechanical Engineering Dr. D.S Kumar , Mechanical Engineering ( Objectives ) Dr. D.S Kumar , Refrigration And Air Conditioner Dr. D.S Kumar , Total Quality Management Dr.K.C.Arora , Engineering Drawing , Ps Gill , Textbook Of Machine Drawing, Ps Gill , Geomatric Dimensioning And Tolerancing , Ps Gill , Computer Aided Drafting Using Autocad , Ps Gill , Learning Autocad , Ps Gill , Auto Cad 2D Design Fundamentals , Ps Gill , Auto Cad 3D Models Fundamentals Ps Gill , Operation Research , Ap Verma , Textbook Of Industrial Management , Ap Verma & N.Mohan , Industrial Engineering And Management , Ap Verma , Stem Tables Rk Singal , Manufacturing Practices ( Workshop Practices ) Rk Singal , Engineering Metrology And Instrumention , Rk Rajput , Strength Of Materials , Rk Rajput , Textbook Of Material Science , Callister , Workshop Technology , Virendra Narula , Manufacturing Process , Virendra Narula , An Intoduction To Nc And Cnc , S.Vishal , Computer Aided Manufacturing, S.Vishal , Automobile Engineering , Km Moeed , Manufacturing Process I Sandy Khippal , Manufacturing Process Ii Sandy Khippal , Principals Of Powder Meatallurgy , Ps Gill , Inspection And Quality Control, Ap Verma , Automation Of Robotics, Khushdeep Goyal , Industrial Automation And Robotics, Khushdeep Goyal , Cnc Machines And Automation , Khushdeep Goyal , Production Planing And Control , Rk Singal , Theroy Of Machines , Rk Singal , Data Book For Designing Machine Elements , Arunkumar , Entreprenurship Development, Ranbirsingh , Unconventional Manufacturing Process , Rahul Jain , Mechanics Of Solids , Timoshenko , Engineering Mechanics , Timoshenko , Mechanics Of Solids , Egor P Popov , Fluid Mechanics And Fluid Power Engineering, Frank M White , Matlab For Dummies , John Mueller , Machine Learning For Dummies , John Mueller , Thermodynamics , Cengel , The Functional Aspects Of Communication Skills, Dr. P. Prasad , Professional Communication, Dr. P. Prasad , Universal English ( In The Twenty-First Century ) Dr. P. Prasad , Effectual Communication Skills , Bhupender Kaur , Engineering Physics, Dr. Abhijit Nayak , Essentials Of Physicsdr. Rakesh Dogra , Engineering Physics ( Aicte ) Dr. Rakesh Dogra , Applied Physics- Imanpreet Singh , Applied Physics -Iimanpreet Singh , Laser Systems & Applications, Dr. Rajesh Mishra , Engineering Physics-I, Dr. Rajesh Mishra , Fundamentals Of Polymer Science & Technology, Anshu Srivastava & Shakun Srivastava , Nuclear Science, Chanchal Garg , Petrochemicals, Anjana Srivastava , Impact Of Science Technology On Society, Ishwar Singh , Introduction To Bioscience , Dr. O.N. Pandey , Introduction To Bioscience Sweety Israni , A Textbook Of Nanoscience , Dr. Rakesh Kumar & Dr. Kamala Pati Tiwary , Professional Communicationdr. Raavee Tripathi , Technical Writing , Dr. O.N. Pandey , Engineering Economics , Dr. O.N. Pandey , Numerical Analysis Dr. Surbhi Gupta & Dr. Abhilasha Sharma , Business Environment , Anita Sengar , Numerical Methods , Girish Nayyar , Human Values And Professional Ethics , Smriti Srivastava , Discrete Mathematical Structures , Adesh K. Pandey & Rakesh Dube , Effective Technical Communication , Dr. Bharti Kukerja, Dr. Anupama Jain , Human Behaviour , Dr. Amit Jain , Organisational Behaviour , Er. Ishwar Singh, Dr. Bratpal Singh , Universal Human Values And Professional Ethics , Dr. Ritu Soryan , Soft Skills , Dr. Ritu Soryan , Communication Skills, Dr. Ritu Soryan , Constitution Of India , Richa Chaudhary, Arunima Mishra, Imran Khan , Concise Engineering Physics , Dr. Shiva Kant Pathak , Discrete Mathematicsanjana Gupta , Discrete Structures, Adesh K. Pandey , Discrete Structure, Kalika Patrai , Applied Mathematics- I, Dr. Hari Arora , Applied Mathematics- Ii, Anita Sachdeva & Hari Arora , Applied Mathematics- I, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Ii, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Iii, Dr. J.S.Bindra And K.S.Gill , Elements Of Engineering Mathematics- I Dr. V.P. Mishra , Elements Of Engineering Mathematics- Ii, Mishra & Mishra , Elements Of Engineering Mathematics- Iii, Mishra & Mishra , Engineering Mathematics-I , Mishra & Mishra , Question Bank In Engineering Mathematics , Mishra & Mishra , A Textbook Of Applied Mathematics-I, Dr. Hari Arora , A Textbook Of Applied Mathematics-Ii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iv , Dr. Hari Arora , A Textbook Of Engineering Mathematics-Ii , Dr. Hari Arora , A Textbook Of Engineering Mathematics-I ( Calculus & Linear Algebra ) , Dr. Hari Arora , Applied Mathematics-Ii ( Previous Year Papers ) Dr. Hari Arora , Numerical Methods And Optimization Dr. Hari Arora , Probability & Statistics Dr. Hari Arora , Differential Equations And Complex Analysis Dr. Hari Arora , Numerical Methods For Engineers And Scientists Dr. Hari Arora , Engineering Mathematics-Iii Amit Gupta , Mathematics ( Cbse ) ( Class - Ix ) Upadhyay & Upadhyay , Mathematics ( Cbse ) ( Class - X ) Upadhyay & Upadhyay , Mathematics ( Cbse ) ( Class - Xi ) Upadhyay & Upadhyay , Mathematics For Mechanical Engineering ( A Solution Manual ) Salman Hussien Omran, Laith Jaffer Habeeb , A Textbook Of Finite Element Method , Pushpam Kumar Sinha , Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry With Experiments , Dr. Sunita Rattan , Comprehensive Engineering Chemistry, Dr. Sunita Rattan , Experiments In Applied Chemistry , Dr. Sunita Rattan , Theory & Practical Of Engineering Chemistry, Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry ( With Experiments ) , Dr. Sunita Rattan , Applied Chemistry- I, Dr. Raman Rani Mittal , Applied Chemistry- Ii, Dr. Raman Rani Mittal , Engineering Chemistry, Dr. Renu Gupta , New Course Engineering Chemistry, Dr. S.K. Bhasin , New Course Engineering Chemistry , Dr. S.K. Bhasin , Realm Of Space Science , Rajeev Garg , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Rajshree Khare , Applied Physics ( Theory & Experiments ) , Ritika Sorot Chauhan, Kavindar Tiwari , Applied Chemistry ( Theory & Experiments ) , Dr. Babita Bhardwaj , Junior English Revised , Haydn Richards => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
TenderDetail
Loading tenders