View Bid Results For Electrical Design Service Tenders

We found 1464 Bid Results related to electrical design service tenders. You can find Contractor details who won electrical design service tenders along with contract details in Bid awards announcements section.

Filters
Stage
978
323
163
Tender Publishing Platform
137
1327
State / UT
34
207
152
141
133
129
90
68
62
62
50
41
35
34
31
30
23
21
18
17
17
15
14
11
11
9
8
7
6
6
5
5
4
1
1
Contract Value
513
133
522
293
Publish Date
5
1
0
0
0
Sector
31
391
245
154
127
126
61
52
45
44
41
29
21
18
15
13
12
8
7
6
5
5
5
5
5
5
4
4
4
3
3
1
Ownership
7
668
416
208
156
10
4
2
Within keyword
Active filters:
Showing 1–30 of 1464 tenders matching your filters
1.
Housing Urban and Rular Development #11475953 Technical Bid
bill of quantities (boq) for renovation of toilets at eight floors (ground floor, 1st, 2nd, 3rd, 4th, 5th, 6th & 7th floors) and pantry at 8th floor of ncdc headquarters building, 4, siri institutional area, august kranti marg, new delhi – 110016 schedule a- civil works sl. no. description of items unit quantity rate amount sub-head : 1 dismantling / demolition works , dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. , dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead , of area 3 sqm. and below , dismantling old plaster or water proofing or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar , dismantling of flushing cistern of all types c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. , vitreous china water closet indian / european , vitreous china wash basins / urinals , dismantling existing floors of bathrooms and toilets as per instructions. the cost inclusive of stacking of dismantled materials (serviceable material) in good condition and also disposal of broken unserviceable materials at contractors own place. , dismantling of existing cp brass fittings, bottle traps and existing gi & ci pipes / fittings, wherever required in toilet as per instructions. the cost inclusive of stacking of existing brass fittings as per instructions of engineer - in - charge and the location directed by him. , dismantling & removal of malbaa from the sunken areas including stacking of serviceable and unserviceable material separately in the lead of 50 mts.after digging the same till the existing waterproofing is visible. the unserviceable material (inclusive of existing waterproofing, if any, of any nature) shall be removed from the sunken areas and the contractor should stack the same at his own place. sub total 0.0 sub head:2 wood work , providing and fixing wood work in frames of doors, windows, celestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). a. sal wood , providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including isi marked stainless steel butt hinges with necessary screws , extra for providing and fixing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter is to be measured for payment purpose). sub total 0.0 sub head:3 finishing work , providing and applying 12mm cement plaster including making grooves wherever required of mix 1:6 . (1 cement :6 coarse sand) , brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. , 12.5 mm thick square edge pvc laminated gypsum tile of size 595x595 mm, made of gypsum plasterboard, manufactured from natural gypsum as per is 2095 part i and laminated with white 0.16mm thick fire retardant pvc film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side pvc film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. , providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. size of tile 800x800 (note: a. base rate of tile in the range of rs.90-95/- per sq.ft. b. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 800x800 mm (note: a. base rate of tile in the range of rs.90 -95 per sq.ft. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. completeat all levels.granite stone slab of colour black, cherry/ruby red , providing and fixing1500x500 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed towooden cleats with c.p. brass screws and washers complete.mirror make:asahi, saint gobain or equivalent as approved by engineer in charge sub total sub head:4 waterproofing work , providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: (i) ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv)ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). , providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. , supplying and filling in sunken with sand under floors, including watering,ramming, consolidating and dressing complete. sub total 0.0 sub-head : 5 plumbing / sanitary work , providing and fixing white vitreous china pedestal type water closet(european type-one piece) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floorswherever required : w.c. pan with isi marked white solid plastic seat and lid , providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests , providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (i)white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps , providing and fixing white vitreous china flat back half stall urinal of 710x485x300 mm or 640x370x310 or 610x390x370mm sizes with white pvc automatic flushing cistern, with fittings,standard size c.p. brass flush pipe, spreaders with unions and clamps (allin c.p. brass) with waste fitting as per is : 2556, c.i. trap with outlet gratingand other couplings in c.p. brass, including painting of fittings and cuttingand making good the walls and floors wherever required : range of two half stall urinals with 10 litre p.v.c. automatic flushing cistern , providing and fixing stainless steel a isi 304 (18/8) kitchen sink as peris:13983 with c.i. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required :kitchen sink with drain board 510x1040 mm bowl depth 225 mm , providing and fixing stone slab with table rubbed, edges rounded and polished,of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting achase of appropriate width with chase cutter and embedding the stone in thechase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6 mm nominal size) as per direction of engineer-in-charge and finished smooth. (granite stone of approved shade) , providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or quivalent make) , 15mm nominal outer dia. pipes , 20mm nominal outer dia. pipes , 32mm nominal outer dia. pipes , 50mm nominal outer dia. pipes , providing and fixing 3 layer pp-r (poly propylene random copolymer)pipes confirming to is:15801 uv stabilized & anti - microbial fusion welded,having thermal stability for hot & cold water supply, including all pp - r plain & brass threaded polypropylene random fittings, including trenching,refilling & testing of joints complete as per direction of engineer-in-charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or equivalent make) , 100mm nominal outer dia. pipes , 150mm nominal outer dia. pipes , all internal sanitary works , providing and fixing c.p. brass long nose bib cock of approved quality (15 mm nominal bore) , providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 , providing and fixing brass 2 in 1 pillar cock of approved quality (15 mm nominal bore) sub total 0.0 total sch a 0.0 schedule b- elctrical works sl.no. description unit quantity rate amount (in rs.) , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required.(wire make- havells, polycab, finolex or equivalent. modular switch, socket, box, plate, etc make- havells, roma or equivalent. steel conduit make-bec, unicon or equivalent) , group c , wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/recessed steel conduit as required.(wire make- havells, polycab, finolex or equivalent) , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.(make- havells, schneider or equivalent) , 250 mm x 300 mm x 100 mm deep , 180 mm x 100 mm x 60 mm deep , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(make- havells, roma or equivalent , 3 pin 5/6 a socket outlet , 5/6 a switch , 15/16 a switch , 6 pin 15/16 a socket outlet , supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc. as required.(make- havells, finolex or equivalent , 8 module (125mmx125mm) , 12 module (200mmx150mm) , 6 module (200mmx75mm) , installation, testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(make- havells, crompton or equivalent , 510 mm sweep , led down lighter (cob type) (system lumen efficacy ≥120 lm/watt ) supplying, installation, testing & commissioning of led recessed/surface down lighter (round / square/ rectangular) cob type of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency 85%, operating voltage ac 140-270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10%, p. f.≥0.95, ip20, cri 80 , ugr (unified glare rating) 19, flicker free (flicker should be below 5 %), life time (led, driver & electrical circuitry), life time of minimum 50000 burning hours with, 70% of initial lumen maintained till life ends , cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted shape size and cct shall be as approved by engineer-in- charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). powder coated die cast /extruded aluminium body including trim with aluminium reflector(make- havells, philips or equivalent) , 12 -15 watt , led batten light (system lumen efficacy ≥120 135 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency 85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f.≥0.95, ip20, cri 80, flicker free (flicker should be below 5 %), life time (led,driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000°k / 4000°k / 5700°k /6500°k 46 delhi schedule of rates (e&m)-2025(as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c).powder coated die cast /extruded aluminium body (thickness 1.20 mm)(make- havells, philips or equivalent) , 18- 22 watt , led strip light (make- philips, wipro or equivalent) , automatic hand dryer (make- dolphy, euronics or equivalent) , automatic touchless toilet urinal sensor alongwith solenoid valve, flexible hose, etc(make- parryware, jaquar or equivalent) total sch b total total (sch a+schb) 0.0 say rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
4.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
5.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
7.
Civil Aviation #11360570 AOC
Bids Are invited for E1 - Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at Salem Airport comprising of LT Panels, DG Sets, CCR Panels, Runway Lighting, High Masts, Perimeter Lighting, Indoor and Outdoor Light Fittings, Power Points, Circuit/Submain Wiring, DBs, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signages etc., (As per Annexure-3 to 5 - List of Inventories ) on duty basis by deputing sufficient number of manpower as per Annexure-1 (8 Hours of Duty of Time as decided by Engineer-In-Charge), Monitoring, Control and General Maintenance for 100% Serviceability and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books (as per Annexure-6 to 20) and reporting as and when required, complete Upkeeping of the Installations etc., on all days as specified and as directed by Engineer-In-Charge as required. , E2 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For First Year (Terminal Building & technical Block (Make- Edwards, Model-IO-1000)) , E3 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For First Year (NDB Room (Make- Edwards, Model-IO-64)) , E4 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For Second Year (Terminal Building & technical Block (Make- Edwards, Model-IO-1000)) , E5 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For Second Year (NDB Room (Make- Edwards, Model-IO-64)) , E6 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (1.5 TR Wallmounted split AC) , E7 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (2 TR Wallmounted split AC) , E8 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (3 TR Tower type split AC) , E9 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (4 TR Cassette type split AC) , E10 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (1.5 TR Wallmounted split AC) , E11 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (2 TR Wallmounted split AC) , E12 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (3 TR Tower type split AC) , E13 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (4 TR Cassette type split AC) , E14 - CMC of 50LPH, 80 ltr tank capacity, Water dispensers of Normal, Cool and Hot mode with inbuilt RO & UV at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. First Year , E15 - CMC of 50LPH, 80 ltr tank capacity, Water dispensers of Normal, Cool and Hot mode with inbuilt RO & UV at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. Secound Year , E16 - Decorating the Airport Terminal building with LED Decorative serial light of 250 coils each coil of minimum 40 LED lamps, running design dispaly, running serial belt of 05 coils preferably in tri colour pattern on the occasion of Independence day / Republic day each time for 3 days including prefix & suffix to the actual day of function etc.as required. , E17 - Providing decorative illumination with multicolour LED colour wash flood light of minimum 10 nos for Independence day / Republic day with required cables and all accessories to illuminate the facia of the buildings each time for 3 days including prefix & suffix to the actual day of function etc.as required as directed by the Engineer -In- Charge. , E18 - Lifting of Submersible Pumps of various capacities from the existing Bore well/Well and reinstalling the Submersible Pumps in the existing bore well / well (After servicing / repairing both are exclusive) complete as required. , E19 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. Upto 3 HP , E20 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 5 to 6 HP , E21 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 10 HP , E22 - Repair & Rewinding of 1400 / 1200 mm Sweep Ceiling fan i/c replacement of spares as required. , E23 - Repair & Rewinding of all capacities of exhaust fan i/c replacement of spares as required. , E24 - Painting of electrical panels, CCR Panels, GLF Fixtures, DGs and street light poles etc., installations with two coats of synthetic enamel paint of approved shade quality and brand after applying two coats of redoxide i/c scrapping and cleaning, providing putty wherever required and inscription etc., as required. , E25 - Execution of items of schedule of rates CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/Terminal Building/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs.2,36,000/- (Inclusive of GST) in INR only and percentage above / below shall be calculated by AAI and paid accordingly. Note- The rate provided in DSR 2022 is inclusive of GST at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For First Year , E26 - Execution of items of schedule of rates CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/Terminal Building/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs. 2,36,000/- (Inclusive of GST) in INR only and percentage above / below shall be calculated by AAI and paid accordingly. Note- The rate provided in DSR 2022 is inclusive of GST at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For Second Year Total Quantity : 312
Contract Date: Ref. Documents Contract Value : 1.14 Crore
Boards / Undertakings / PSU No of Bidders 5
8.
Housing Urban and Rular Development #11346479 Technical Bid
Tender for Construction Of Modular Ot Eye Under Old Sadar Hospital At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
9.
Housing Urban and Rular Development #11346477 Technical Bid
Tender for Construction Of Modular Ot (Eye) Under Sub Divisional Hospital At Madhupur Dist Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
10.
Housing Urban and Rular Development #11346476 Technical Bid
Tender for Construction Of Modular Ot (General & Gynae) At Chc Under Sarwan Block At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Multi Purpose Ot Table With C - Arm Compitable , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro-Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
11.
Housing Urban and Rular Development #11333527 Technical Bid
Tender For Rate Contract For Tentage Work Like Safe House, Dome, Stage Etc. Construction Including Barricating And Miscellaneous Works And Electric Work While Vip Visits Under Pwd Division Dungarpur Distt Dungarpur= 1 Hire Charges Includes Transporatation At Site Within Division Boundary, Loading, Unloading, Placing And Removing Complete. For Any Place With In Division Boundary. Hire Charges For 3 Days.Chairs : Pvc Chair 2 Plastic Cane Chair Of Aluminium Pipe With Arms. Steel Pipe Pedded Chair 3 Tables :Tables : Wooden Table 6 X 3 (Babool). 4 Tables : Centre Table Glass Top 2X4 5 Floor Covering :Cotton Durry (Old). 6 Cotton Durry (New). 7 Non Woven Synthtic Carpet (Red/Green) (New) 8 Woolen Carpet (New). 9 White Cotton Chader (Sheet) (Washed) 10 Pipe Pandal With Covering Ht From To 12 To 18 Ft 11 Curtain Cloth (View Cutter ) Made Out Of Steel Pipe Frame Covering With Good Quality White Cloth To Cut View Including Making Holes And Made Necessary Strengthening Support Against Wind Pressure Complete . 12 Kanat Fixed With Tent. (15X6) 13 Kanat Fixed Without Tent. (15X6) 14 5Mm Galvanised Iron (G.I) Pipe 6 Mtr. Long With New Silk Flag. 15 Water Proof Tripal. 16 Wooden Stage Height 60Cm.With Steps Complete 17 Wooden Stage Height 120 To 180 Cm.With Steps Made Of 50 Mm Dia Iron Pipe Frame With Adjustable Height System And Having Smooth Top Wooden Board Complete . 18 Cotton Mattress With White Sheet (Chader). 19 Dunlop Mattress With White Chadar Size 6X3. 20 Massand With White Cover. 21 Speech Stand Having Sunmica Top. 22 White Cotton Cloth Cover For Padded Chair Inculding Ribbon 23 Barricading With Sal Ballies As Per Design Including Tying With Vertical Post By Coconut Strings Including Digging Out Holes In All Types Of Soil Complete In All Respect With Two Horizontal Members Height 1.2 M Upto 1.5M Above Ground Level And Vertical Supports Upto 2.5 Centre And Upto 3 Days Period Including Removal And Cleaning The Site Complete In All Respect & Including Dressing Of Sides And Providing Retro Reflective Tapes For Traffic Safety As Per Direction Of Engineer-In Charge In All Types Of Soil. 24 Barricading With M.S. Pipe As Per Design Including Tying With Vertical Post Including Digging Out Holes In All Types Of Soil Complete In All Respect With Two Horizontal Members Height 1.2 M Upto 1.5M Above Ground Level And Vertical Supports Upto 2.5 Centre And Upto 3 Days Period Including Removal And Cleaning The Site Complete In All Respect & Including Dressing Of Sides And Providing Retro Reflective Tapes For Traffic Safety As Per Direction Of Engineer-In Charge In All Types Of Soil. 25 Making Of Holes In Cement Concrete/ Bitumenous Road By Power Driven Hammer For Barricating Work As Per Direction Of Engineer In Charge 26 Hire Charges For Folded Type Two Seater Sofa Set (Cum Bed) With Good Quality White Cloth Cover 27 Vip Chair With Cushion 28 Add Extra For Hire Charge For Providing Welded Mesh Size 25X25 Mm (16Swg) Over Barricating (Excluding Hire Charge Of Barricating) 29 Water Proof Tent With Pipe Pandal Supported With Bamboo/Balli /Ms Pipe Frame. 30 Water Proofing Canopy With Ornamental Frill, Inner Ceiling & Curtains Above Size 20X20 31 Three Seater 32 Chemical Toilet With House Keeping Arrangement And Providing Liquid Soap, Tissues, Comb, Freshener Etc. 33 Water Proof Dome With Truss Steel Strcture, Inner Ceiling & Curtains 90 Span 34 Aluminium German Hanger Tent Roof Made Up Of Waterproof, Fire Resistant Synthetic Rubber Fabric Of 885 Gsm. 35 Hire Charges For Led Flood Light Luminaire ( White Or Warm White As Required )For 90- 150 Watt With The Standard Housing ,Pole & Mounting Accessories With Wiring, Connection With Skilled Operator To Operate System Etc. As And When Required. With Suitable Pole For 1St Day 36 For 2Nd / 3Rd Day 37 Without Suitable Polefor 1St Day 38 For 2Nd / 3Rd Day 39 Hire Charges For Led Screen Day Light Type (P3.9) Of Suitable Size For Display Complete With Mounting Arrangement/Scaffolding, Masking Of Mounting Stand, Signal Booster, Network Switch /Splitter, Data And Power Cables And Sound System Arrangement Etc. With Skilled Operator To Operate System Etc. As And When Required. For 1St Day 40 For 2Nd / 3Rd Day 41 Hire Charges For Hd Video Camera Suitable For Sdi/Hdmi Output, Recording In Dvd/Hard Disk Fuction Complete With Two Operator As And When Etc As Required. For 1St Day 42 For 2Nd / 3Rd Day 43 Hire Charges For Video Projection Arrangement (Excluding Screens) With 3 Nos. Video Camera (Pwm 120 Sony Nx 5Z7/Equivalent) Including Mixer (Pansonix Mx70/Data Video Mx500/ Equivalent) Complete With Required Hdmi/Sdi Etc. Wiring Vtr, Switchers, With Skilled Operator To Operate System Etc As And When Required. For 1St Day 44 For 2Nd / 3Rd Day 45 Hire Charges Of Crane With Operators For Video Camera For 360° Movement Complete Arrangement With Skilled Operator To Operate System As And When Etc As Required. For 1St Day 46 For 2Nd / 3Rd Day 47 Hire Charges For 42\ Hd Led/Plazma Tv Complete With Mounting Arrangement , Connections, Testing Etc. With Skilled Operator To Operate System Etc As And When Required. For 1St Day 48 For 2Nd / 3Rd Day 49 Hire Charges For 50/52\/Higher Sizes Hd Led/Plazma Tv Complete With Mounting Arrangement , Connections, Testing Etc.With Skilled Operator To Operate System Etc As And When Required. For 1St Day 50 For 2Nd / 3Rd Day 51 Hire Charges For Equipments Required For Public Address & Sound System For A Very Important Public Function/ Vvip Visits Including Transportation,T&P,Scafolding, Testing And Connections With Trial Etc. With Skilled Operator To Operate System Etc As And When Required. 15 Inch 3 Way Line Array Speaker Adamson E15/L Acoustics -K1/D&B Gsl Or Equivalent Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 52 For 2Nd / 3Rd Day 53 12 Inch 3 Way Line Array Speaker Adamson E12/L Acoustics -K2/D&B Gsl/Jbl A-12 Or Equivalent Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 54 For 2Nd / 3Rd Day 55 Pentium -Iv Laptop With Hdmi Cable & Stereo Sound Output Make-Hp/Dell/Lenovo Or Equivalent As Approved By Engineer In Charge.For 1St Day 56 For 2Nd / 3Rd Day 57 Cross Overs For The Speakers Distributions Make- Dbx Or Equivalent As Approved By Engineer In Charge.For 1St Day 58 For 2Nd / 3Rd Day 59 Amplifier Suitable For The Installed Speakers/Sound System As Required.For 1St Day 60 For 2Nd / 3Rd Day 61 Suspension Kits With Suitable Stand For The 3-Way Speakers As Required.For 1St Day 62 For 2Nd / 3Rd Day 63 Required Necessary Snake Cables,Audio Connection Cables, Speakers Cables,Electrical Wiring, Boards, Connector Etc For Speakers/Horns Etc. As Required For 1St Day 64 For 2Nd / 3Rd Day 65 Top Speakers Jbl/Rcf Or Equivalent. As Approved By Engineer In Charge.For 1St Day 66 For 2Nd / 3Rd Day 67 Monitor Speakers Jbl/Rcf Or Equivalent. (For Stage) As Approved By Engineer In Charge.For 1St Day 68 For 2Nd / 3Rd Day 69 Cordless Mike Hi -End(For Vvip Visit)With Antenna Combiner Etc.Make:-Shure .Ad4D/Sennheiser 6000 Or Equivalent.Reputed Make/Model As Approved By Engineer In Charge..For 1St Day 70 For 2Nd / 3Rd Day 71 Digital Mixer (128+48) Digico Sd10/Avid S6L 24C/Dlive 7000 Or Equivalent..Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 72 For 2Nd / 3Rd Day 73 Channel Mixer Digital (32+16) Midas M32/Sq7/ Sound Craft S1 Or Equivalent.Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 74 For 2Nd / 3Rd Day 75 Effect Processors. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 76 For 2Nd / 3Rd Day 77 Compressors. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 78 For 2Nd / 3Rd Day 79 Amplifiers 700 Watt Rms At 100 Ohm.For Horns Make:-Ahuja/Qsc Or Equivalent As Approved By Engineer In Charge.For 1St Day 80 For 2Nd / 3Rd Day 81 Mikes With Big Stand. Make:-Shure/Akg/Sennheiser Or Equivalent As Approved By Engineer In Charge.For 1St Day 82 For 2Nd / 3Rd Day 83 32 Band Equalizer. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 84 For 2Nd / 3Rd Day 85 Snake Cable/Audio Cable/ Bnc Cable /Cat 6 Cable (100 Mtr) Including Accessories, Connection, Testing Etc. As Required.For 2Nd / 3Rd Day 86 For 2Nd / 3Rd Day 87 Hire Charges For Light Point Complete With Lamp,Holder,Wiring In Casing Or In Pvc Conduit , Controlling Switch And Circuit Protection McbS With Skilled Operator To Operate System As And When Etc As Required. For Shops/ Stalls Etc. For 1St Day 88 For 2Nd / 3Rd Day 89 Hire Charges For Power/Light Plug On Board Including Wiring In Pvc Casing Or In Pvc Conduit , Controlling Switch And Circuit Protection McbS With Skilled Operator To Operate System As And When Etc As Required. For Shops/ Stalls Etc. For 1St Day 90 For 2Nd / 3Rd Day 91 Hire Charges For Led Tube Light Fixture With 18/20 Watt With Skilled Operator To Operate System As And When Etc As Required.For 1St Day 92 For 2Nd / 3Rd Day 93 Hire Charges For Silent Type D.G. Set, Including Change Over Switch. Control Panel, 2 No. Pipe Earthing Etc. And Excluding Pol With Skilled Operator To Operate System As And When Etc As Required. Of Following Capacity:62.5 Kva 94 From 2Nd Day Onwards 95 125 Kvafor 1St Day 96 From 2Nd Day Onwards 97 Hire Charges Of Main Service Line For 3 Phase Connection Upto 50 Mtr. Length (Without Any Joint) Including Meter Board, Panel/Distribution Board And Supports With Skilled Operator To Operate System As And When Etc As Required. Upto 25.0 Sq.Mm Size Pvc Insulated And Sheathed Cable( Aluminium Armoured Or Un-Armoured As Required.) For 1St Week 98 For 2Nd / 3Rd Day 99 Above 25.0 Sq.Mm & Upto 95 Sq.Mm Pvc Insulated And Sheathed Cable Aluminium Armoured Or Un-Armoured As Required.)For 1St Week 100 For 2Nd / 3Rd Day 101 Above95.0 Sq.Mm Pvc Insulated And Sheathed Cable Aluminium Armoured Or Un-Armoured As Required.)For 1St Week 102 For 2Nd / 3Rd Day 103 Supply And Filling Of Pol For Dg Sets 104 Hire Charges Of Sub Service Line For Single/ Three Phase Connection Upto 30 Mtr. Length Including Dist. Board And Supports With Skilled Operator To Operate System As And When Etc As Required. Single Phase Upto 6 Sqmm Pvc Insulated And Sheathed Aluminium Cablefor 1St Week 105 For 2Nd / 3Rd Day 106 Three Phase & Neutral Upto 10 Sqmmpvc Insulated And Sheathed Aluminium Cablefor 1St Week 107 For 2Nd / 3Rd Day 108 Hire Charges For Jumbo Polycarbonate/Fiber Body Moveable Desert Cooler Complete With Water Filling And Operator With Skilled Operator To Operate System As And When Etc As Required. For 1St Day 109 For 2Nd / 3Rd Day 110 Hire Charges For Following Type Of Airconditioners Including Copper Piping , Drain Piping And Electrical Connections With Skilled Operator To Operate System As And When Etc As Required. 3.0 /4.0 Tr Tower Type Split Acfor 1St Day 111 2Nd Day Onwards 112 Hire Charges Of 1 Kva Online Ups With Battery (Backup Of 1 Hour At Full Load) With Wiring,Connection With Skilled Operator To Operate System As And When Required.. For 1St Day 113 For 2Nd / 3Rd Day 114 Hire Charges Of Public Address System For A Important Public Function With 5/ 6 No. Of Microphones With Following Nos Of Stand Hi Fi Box, Speakers/ Horns, Stand By Amplifiers , Battery Backup Complete Including Transportation Etc. With Skilled Operator To Operate System As And When Etc As Required. : 4 Nos 3 Way Big Box Speakers And Upto 20 Horn(5000 Audiences)For 1St Day 115 For 2Nd / 3Rd Day 116 Pipe Earthing As Per Is:3043- 1987 With 3.0 Mtr. Long, 40 Mm Dia. B Class G.I. Pipe Is: 1239 (Part-1) 2004, Equivalent To Bs : 1387 With Perforated Holes Of 12 Mm Dia ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, Heavy Duty Weather Proof Poly-Propylene Earth Inspection Chamber As Per Requirement Of Is/Iec 62305 And Tested As Per Iec 62561-5 With Lockable Jam Free Lid Suitable For Safe Working Load 60 Kn Of Round / Square Size 250 Mm, And Height 250 To 300 Mm And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required. 117 Hire Charges For Following Type Of Airconditioners Including Copper Piping , Drain Piping And Electrical Connections With Skilled Operator To Operate System As And When Etc As Required. 8.5 Tr Ductable Type Split Acfor 1St Day
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
12.
Defence #11328000 AOC
Bids Are Invited For Superstructure Of Fiber Glass Hut Frp Shelter 8 To 10 Men Of Size 6 Point 00 M X 4 Point 80 M X 2 Point 70 M Height As Per Ce Comma Hq 4 Corps Drawing No Ce 4 Corps , Cement 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt Conform To Is 8112 1989 , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40Mm Graded , Coarse Aggregate 40 To 63Mm Graded , Stone For Rr Messonry Less Than 6 Inch , Mild Steel Bars Of Size 6 To 8Mm Dia Conforming To Is 432 Part I 1982 , Mild Steel Bars Of Size 10Mm And Above Dia Conforming To Is 432 Part I 1982 , Water Proofing Compound Conform To Is 2645 2003 , Ms Binding Wire , Quick Setting Compound , Bricks Sub Class B , Brick Bats , Pvc Pipe 110 Mm Dia 3 M Long , Pvc Bend 110 Mm Dia , Pvc Socket 110 Mm Dia , Water Storage Tank Triple Layer 500 Ltrs Confirming To Is 12701 1996 , Fabrication From Structural Steel Section For Staging Of Water Storage Tank Made Of Capacity 500 Oblique 1000 Ltrs , Chromium Plated Piller Cock Swan Neck With Aerator And Butter Fly Handle Weight Not Less Than 450 Gm , Stop Cock L Type Chromium Plated Brass 15 Mm Weight Not Less Than 330 Gm , Bib Cock Long Spout Brass Chromium Plated 15 Mm Weight Not Less Than 330 Gm , Pvc Connection 45 Cm Long 15 Mm , Soap Dish Ss Comma Flat Back Complete With Screw , 2000 Ltrs Anaerobic Frp Oblique Ldpe Septic Tank , Pvc Air Pipe 25 Mm Dia , Ppr Elbow 90 Degree 20 Mm Dia , Ppr Female Thread Socket 20 Mm Dia , Ppr Male Thread Socket 20 Mm Dia , Ppr Female Thread 90 Degree Elbow 20 Mm , Ppr Female Thread Tee 20 Mm , Ppr Plain T 20 Mm Dia , Ppr Elbow 90 Degree 32 Mm , Ppr Plain T 32 Mm , Pvc Wall Clamp 32 Mm , Pvc Wall Clamp 20 Mm Dia , Gate Valve 32 Mm , Gate Valve 20 Mm Dia , Ppr Pipe 32 Mm Dia , Ppr Pipe 20 Mm Dia , Ppr Socket 32 Mm , Ppr Socket 20 Mm Dia , Tank Connector 32 Mm , M Seal 150 Gm Pkt , Taflon Tape Roll Isi Marked , Solvent Cement 150 Gm Tube , Pvc Waste Pipe 32 Mm And 1M Long , Pvc Waste Pipe Cp Coupling 32 Mm Dia , Pvc Pipe 110 Mm Dia Each 3 Mtr Length , Pvc Bend110 Mm Dia , P Trap Vitreous China , Cp Grating 100 Mm Dia , S Trap Vitreous China , Distribution Box 6 Way Double Door Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud Conforming To Is 13032 And Is 8623 Double Door Type Comprises With The Mcb , Mcb Spn 240 Volts 32 Amps , Mcb Sp 6 To 32 Amps , Pvc Tape 19Mm Wide 5 M Long , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 1 Point 5 Sqmm Single Core Frls Confirming To Is 1554 Part 1 1988 , Cable Pvc Insulated Elecric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 2 Point 5 Sqmm Single Core Frls Confirming To Is 1554 Part1 1988 , Pvc Casing Capping 1 Inch X 6 Feet Long Medium Grade Snow White , Pvc Casing Capping 3 Oblique 4 Inch X 6 Feet Long Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White , Led Tube Light Fittings 20W Rechargable Type 230V Box Type 2 Feets With Crca Body Pre Coated White And Prewired For Led Tube Complete , Screw Full Thread 6 X 19 Mm Isi Marked Comma 200 Nos Pkt , Pvc Switch Board Snow White Size 7Inch X 4 Inch For Sockets And Switches , Pvc Switch Board Snow White Size 8 Inch X 10 Inch For Main Switches Db , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15 Amp 230 Volts , Switch Socket Combination Snow White 5 Amp 230 Volts , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5 Mtr Long , Service Cable Pvc Insulated Aluminium Conductor Comma 1100 Volt Grade Heavy Duty Served With Inner Sheathing Of Pvc Tap And Overall Pvc Sheathed In Service Connection 10 Sqmm 2 Core , Ceiling Rose Three Terminal Snow White , Led Bulk Head Fitting High Pressure Die Cast Aluminum Front Cover With Glass Cover With Specially Design Gasket With Led Lamp 10 Watts Rechargable Type , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Oblique 76 , Pvc Flexible Conduit Pipe 15 Mm Dia , Pvc Round Oblique Square Block , Pvc L Bend And T Junction Joint For Pvc Casing And Capping , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings Comma Drilled With 2 Nos Holes For 6 Mm Dia Near One Side , Ci Earth Pit Cover Of Size 300 X 300 X 6 Mm With Angle Iron Of Size 20X20Mm Comma 3 Mm Thick With Ms Frame , Funnel Fitted With 20 Mm Diameter Gi Pipe 1 Point 5 M Long Pipe , Gi Wire 4 Mm Diameter For Earthing , Charcoal , Salt Normal , Air Termination Single Pointed Aluminium Rod 12 Mm Dia And 300 Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronze Size 75 X 75 X 25 Mm Drilled And Screwed Including 3 Nos 8 Mm Dia 25 Mm Long Hexagonal Head Screw , Aluminium Strips 25 X 3 Point 0 Mm , Galvanized Iron Strip 32 X 6 Mm , Funnel Fitted With 20 Mm Diameter Gi Pipe 1 Point 5 M Long , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings Comma Drilled With 2 Nos Holes For 6 Mm Dia Near One Side , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Double Sleeping Bunk Alongwith Ply Wood And Mattress , Portable Indoor Type High Quality Kero Heater Metal Body Ignites Type Of Continues Heating Duration Min 8 Hrs And Above With Capacity 4 Ltrs Above Min Output 7000 Btu Per Hrs Incl All Accessories , Kassi With Handle , Black Steel Sr Shovel Spade Belcha , Plaster Trowel With Wooden Handle , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm , Plumb Bob Iron , Crow Bar 1 Point 5 Inch Dia 4 Feet Long , Hammer 1 Kg With Wooden Handle Durmut , Hammer 0 Point 5 Kg With Wooden Handle Durmut , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 Inch 305Mm , Sprit Level , Measuring Tape 30 Mtr Steel , Water Bucket Steel 13 Inch Dia , Picks Axes With Chisel And Point Ends Kudali 14 Cp Nominal Weight 3 Point 0 Kg , Lime Brush Best Quality , Painting Brush 100Mm , Hacksaw Frame Large With Blade 05 Nos , Galvanised Iron Pan Mortar Tasla Comma 18 Gauge 20 Inch Dia , Wooden Waterproof Plywood Thickness 12Mm , Nails Various Sizes , Rammer Earth With Handle Minimum Weight 5 Kg Without Handle , Tester For Electrician With Plastic Handle 150Mm , Electric Drill Machine Heavy Duty 500 Watt Electrical Backup With Battery And Charger , Drill Bits Hss 5Mm Comma 8Mm And 10Mm Dia For Electric Drill Machine , Electric Tile Cutting Machine With Interchangable Blades 05 Nos , Electrical Sheet Cutter Machine With Blade , Puf Rivet Machine , Centre Punch 8Mm Dia Best Quality Total Quantity : 3056
Contract Date: Ref. Documents Contract Value : 11.40 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
13.
Petroleum and Natural Gas #11322090 AOC
Bids Are invited for Custom Bid For Services - Construction Of Compressor Shed With Associated Civil And Electrical Works For Operation Of Two Nos Screw Type Air Compressor At Ihb Mithirohar Pumping Station In Gujarat - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas Including Dressing Of Sides And Ramming Of Bottoms Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil, All Works Up To Any Lead And Lift, As Directed By The Engineer-In Charge : In All Kinds Of Soil. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of The Engineer-In-Charge. [Notes: (1) Dismantling Shall Be Allowed During Day Shift Only & Prior Permission For The Same Shall Be Obtained. (2) Providing Of Necessary Covers/ Barricades Around The Work Area Shall Be Done Prior To Dismantling Operations.]Nominal Concrete 1:4:8 Or Leaner Mix. , Supplying & Fixing Welded Wire Mesh Door Made From Steel Wire Fabric Of Rectangular Mesh 75 X 25 Mm Size, Weight Not Less Than 7.75 Kg/Sqm Fixed On Angle Iron Frame By Welding, Fixing Of Holdfast, Hinges, Door Handles, Tower Bolts, Aldrops (2 Nos.), Wheels, Painting With Two Coats Of Synthetic Enamel Paint Of Over A Coat Of Red Oxide Zinc Chrome Primer, Excluding Frame Etc. Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Drawings, Specifications And Directions Of The Engineer-In-Charge. (Note: Angle Iron Frame Shall Be Paid Separately). , Providing And Laying In Position Cement Concrete Of Specified Grade Including The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cementconcrete For Reinforced Cement Concrete Work;Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources,Portland Pozzolana /Ordinary Portland/Portland Slag Cement,Admixtures In Recommended Proportions As Per Is:9103 To Accelerate /Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, The Cost Of Centering, Shuttering,Finishing, Curing,Carriage For All Leads,As Per Direction Of The Engineer-In-Charge,For The Following Grades Of Concrete.:Note: 1. Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. Incase The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bearthe Cost Of Extracement. 2.Payment For Reinforcement Shall Be Made As Per Relevant Item Of Sor. ;All Works Upto Plinth Level ; Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg /Cum , Supplying, Cutting,Bending, Hoisting,Placing In Position Withproper Pre-Castconcrete Block Coverand Binding By Pvc Coated (Extrusion Process) 18 Guage Swgwire, High Yield Strengthdeformed Bars Of Grade Fe500 Conforming To Is:1786 With Protectivefusion Epoxy Coating Asper Is:13620 For All R.C.C Works Including All Necessary Handling At All Heights And Depths Complete In All Respects As Per Specifications And Directions Of The Engineer-In-Charge. , Brick Work With Common Burnt Clay F.P.S. (Non Modular)Bricks Of Class Designation 7.5 Infoundation And Plinth In : Cement Mortar 1:6 (1Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brickwall Of Mix : 1:6 (1 Cement : 6 Fine Sand) , 6 Mm Cement Plaster Of Mix 1:3 (1 Cement : 3 Fine Sand) , Supplying, Fabricating, Erecting, Placing And Fixing In Position M.S. Structural Works Using Rolled/ Built Up Sections For Truss, Claddings, Bracings, Purlins, Supporting Frames Made Of Joists, Tubes, Pipes, Channels, Angles, Plates, Flats, Bars Etc. Including Cutting To Required Size Welding Of Joints, Fixing Anchor Plates, Including Bolts, Theading, Nuts, Washers, Sleeves Etc. Including Preparation Of Detailed Fabrication Drawings & Submission To The Engineer-In-Charge For Approval Before Start Of Fabrication, Supplying & Applying Painting With Two Coats Of Epoxy Paint Epilux 155 High Build Enamel Over A Coat Of Epilux 610 Primer Of M/S Berger Or Any Other Approved Equivalent Make As Per Manufacturers Recommendation, Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Drawings, Specifications And Directions Of The Engineer-In-Charge. (Excluding The Cost Of Concrete Work). , Providing And Laying 52 Mm Thick Cement Concrete Flooring With Metallic Hardner, Under Layer Of 37 Mm Thick Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) And Top Layer Of 15 Mm Thick Metallic Concrete Hardner Consis Ting Of Mix 1:2 (1 Cement : 2 Stone Aggregate 6 Mm Nominal Size) By Volume With Which Metallic Hardening Compound Such As Ironite No . 1 Of Ironite Co. Of India Ltd. Or Aproved Equivalent Mixed In The Ratio 4:1 (4 Parts Of Cement : 1 Part Of Metallic Floor Hardenin G Compound Of Approval Quality) By Weight, Inclusive Of Cost Of Finishing, Labour, Material, Equipment, Etc. As Per Specifications A Nd Directions Of The Engineer-In-Charge. , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) : 6 Graded Stone Aggregate 40 Mm Nominal Size) , Supplying And Layingflat Brick Soling Infoundation Trench, Infloors, Garages, Sumps,Etc., With Bricks Of Classdesignation 50 Laid Toproper Slope, Level Andgrade Etc. Filling Of Thejoints With Sand Etc.Complete In All Respectsinclusive Of Cost Of Alllabour, Materials, Tools,Tackles Etc. As Perdrawings, Specificationsand Directions Of Theengineer-
Contract Date: Ref. Documents Contract Value : 24.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
14.
Tourism #11320518 Technical Bid
Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.-1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil Dsr-2.6.1 170.25 Cum 133.12 127.80 21757.52 In All Kind Of Soil Upto 1.5M To 3.0M. Depth 2.6.1+2.26.1 18.74 Cum 228.22 219.09 4106.24 In All Kind Of Soil Upto 3.0M To 4.5M. Depth 2.6.1+(2.26.1* 2) 6.37 Cum 323.31 310.38 1977.88 2 Excavation Of Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. Dsr-2.1.1 35.61 Cum 97.38 93.49 3329.14 3 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. Dsr-2.25 8.70 Cum 147.00 141.12 1227.84 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete Dsr-2.25(A) 55.60 Cum 525.36 504.34 28041.40 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) Dsr-4.1.8 70.78 Cum 5108.83 4904.47 347162.56 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr-2.27 26.31 Cum 1592.76 1529.05 40229.27 7 Diluting And Injecting Chemical Emulsion For Postonstructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration Dsr-2.35.3.1 194.47 Sqm 232.53 223.23 43411.24 8 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Dsr-5.3 82.66 Cum 8628.83 8283.68 684729.10 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) Footing Dsr-5.1.2 21.98 Cum 6784.08 6512.72 143149.60 10 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Dsr-5.2.2 22.97 Cum 8139.44 7813.86 179484.39 Abstract Of Cost Delhi Schedule Of Rate Effective From 12/07/2023 X (0.735X106/107X1.03) Has Been Followed. Proposed Tourism Development Of Ramjanki Temple At Kotawari, Tilhar, Sahjahanpur, U.P. 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr-5.9.5 257.49 Sqm 552.28 530.19 136518.66 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr-5.9.3 407.10 Sqm 695.41 667.60 271778.96 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Dsr-5.9.1 63.96 Sqm 294.10 282.34 18058.37 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts Dsr-5.9.6 208.86 Sqm 720.95 692.11 144554.66 15 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr-6.1.1 16.84 Cum 5527.80 5306.69 89341.45 16 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.1.2 51.30 Cum 5349.01 5135.05 263427.92 17 Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). Dsr-4.11 2.14 Sqm 371.80 356.93 763.83 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. Dsr-4.13 44.55 Sqm 109.61 105.22 4687.75 19 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.4.2 80.04 Cum 6829.23 6556.06 524747.32 20 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Dsr-6.13.2 60.18 Sqm 842.82 809.11 48692.17 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More Dsr-5.22A.6 186.64 Qtl 8088.48 7764.94 1449250.34 22 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Coarse Sand) Dsr-13.5.1 65.74 Sqm 308.80 296.45 19488.62 23 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.5.2 252.10 Sqm 296.50 284.64 71758.35 24 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.4.2 609.85 Sqm 257.73 247.42 150888.63 25 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. Dsr-5.30 315.01 Rm 58.80 56.45 17781.09 26 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr-11.3.1 29.40 Sqm 460.63 442.21 13000.95 27 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement.18 Mm Thick Dsr-11.6.1 3.35 Sqm 496.52 476.66 1596.81 26 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr-11.41.2 137.75 Sqm 1165.05 1118.45 154065.99 27 Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To |.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm Dsr-11.46.2 10.17 Sqm 1217.25 1168.56 11884.22 28 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr-11.37A 148.53 Sqm 812.00 779.52 115781.77 29 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Dsr-11.39 4.40 Sqm 997.47 957.57 4213.30 30 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Ordinary Cement Without Any Pigment 11.20.4 6.12 Sqm 792.24 760.55 4654.54 31 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 35 Mm Thick Dsr-9.5.1.1 6.30 Sqm 3083.86 2960.50 18651.18 32 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Dsr-9.5.1.2 83.22 Sqm 2810.38 2697.97 224524.67 33 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws Dsr-9.21.1 15.33 Sqm 1794.43 1722.65 26408.23 34 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10X15Cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). Dsr-9.53 128.00 Nos 171.63 164.77 21090.11 35 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding Dsr-9.48.1 937.05 Kg 164.32 157.75 147816.54 36 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). Dsr-10.13.1 100.80 Kg 106.27 102.02 10283.67 37 Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35X5 Mm, Joints Mitred And Welded By Angle Iron 35X35X5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer-In-Charge. Dsr-10.31 125.00 Kg 97.87 93.96 11744.60 38 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Dsr 10.28 133.33 Kg 579.28 556.11 74146.05 39 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).(Sal Wood) Dsr-9.1.2 1.61 Cum 87387.28 83891.79 135065.79 40 Fixing Of Door, Windows/Ventilators Chaukhats In Position. (A) Door Chaukhats Above 1.5 Sqm To 5.0Sqm Mr 19.00 Nos 150.00 144.00 2736.00 (B) Window Chaukhats Above 1.5 Sqm 12.00 Nos 100.00 96.00 1152.00 (C) Ventilator Chaukhats 7.00 Nos 50.00 48.00 336.00 41 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) Dsr-13.47.1 407.00 Sqm 128.32 123.19 50137.46 42 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr-13.41.1 434.15 Sqm 139.23 133.66 58030.01 43 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Dsr-13.80 841.15 Sqm 117.03 112.35 94505.07 44 Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm Dsr-9.62.2 11.00 Nos 145.27 139.46 1534.05 45 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm Dsr-9.63.1 21.00 Nos 62.92 60.41 1268.53 200X10 Mm Dsr-9.63.2 65.00 Nos 52.05 49.97 3247.81 46 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :100 Mm Dsr-9.66.2 54.00 Nos 24.41 23.44 1265.50 47 Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete Dsr-9.82 1.00 Nos 91.23 87.59 87.59 48 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm Dsr-22.7.1 198.55 Sqm 1263.41 1212.87 240815.58 49 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture Dsr-13.48.3 144.65 Sqm 128.02 122.90 17777.47 50 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture Dsr-13.48.2 209.70 Sqm 132.18 126.90 26610.03 51 Providing & Fixing Panes Of Glass With Equal Or Equivalent I.S.I Marked Quality Putty. Brads And Springs And Including Supply Of All Materials And Labour Etc Complete . 3.8 To 4.7 Mm Thick Dsr-10.30.1 44.76 Sqm 805.96 773.72 34631.80 52 Supply And Fixing Of Drop Down Rail / Grab Bars Mr 4.00 Nos. 4400.00 4224.00 16896.00 53 Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap) : 400 Mm Dia Piles Dsr-20.1.1 48.00 Rm 2075.18 1992.17 95624.30 54 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 30 Mm Thick Dsr-8.14.1.5 50.74 Sqm 3971.79 3812.92 193478.98 55 Stone Work In Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Including Pointing With Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade Both Face Dressed Red Sand Stone Dsr-7.12.1.1 3.56 Cum 51218.78 49170.03 175241.97 56 Extra For Stone Work Ashlar Sunk Or Moulded Or Sunk And Moulded Or Carved In : Triangular Or Square Or Rectangular Pillars Dsr-7.21.1 3.56 Cum 2834.15 2720.79 9696.89 57 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr-8.15 99.58 Kg. 535.78 514.35 51219.04 58 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 50Mm Dsr 8.14.1.3 37.80 Sqm. 4342.28 4168.59 157572.62 59 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 30.00 Nos. 32.92 31.61 948.21 60 Providing And Fixing Stone Jali 40 Mm Thick Throughout In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc. Red Sand Stone Dsr 7.33.1 4.50 Sqm. 11198.29 10750.35 48376.59 61 Stone Work, Plain In Copings, Cornices, String Courses And Plinth Courses, Upto 75 Mm Thick In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade.: Red Sand Stone Dsr 7.32.1 0.47 Cum. 70303.46 67491.32 31720.92 62 Carving & Engraving Work On Red Sand Stone (Labour Only) M.R. 9.73 Sqm. 15615.00 14990.40 145856.59 63 Manufacturing, Supplying And Fixing Retro Reflective Overhead Signage Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineerincharge.( Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage Dsr 16.60.1 8.64 Sqm. 4409.78 4233.39 36576.45 64 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Dsr 8.2.2.2 34.45 Sqm 3852.10 3698.01 127396.50 65 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Dsr-4.17 6.00 Sqm 561.96 539.48 3236.87 66 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50 Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-35 Grade With Approved Colour Design And Pattern Dsr-16.91.2 207.07 Sqm 818.60 785.85 162723.31 1 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fitting And Fixtures Completed Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests 17.1.1 2.00 Nos. 5075.38 4872.36 9744.73 2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Isi Marked White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required. W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 17.2.1 3.00 Nos. 4886.50 4691.04 14073.11 3 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require A) White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 17.7.4 4.00 Nos. 1409.35 1352.98 5411.91 4 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required A) One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 17.4.1 3.00 Nos. 4918.90 4722.14 14166.42 5 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete. Flexible Pipe 17.28.2 A) 32Mm Dia 17.28.2.1 4.00 Nos. 89.66 86.07 344.29 B) 40Mm Dia 17.28.2.2 2.00 Nos. 89.66 86.07 172.15 6 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 17.31 4.00 No. 1205.92 1157.69 4630.74 7 Providing And Fixing Cp Brass Single Lever Lelephonic Wall Mixture Of Quality & Make And As Per Thedirection Of Enginer-Incharge. A) 15Mm Dia Nominal Dia. 17.22B 2.00 Each 5205.39 4997.17 9994.34 8 Providing And Fixing 8 Mm Dia C.P./S.S. Jet With Flexible Tube Upto 1 Meter Long With S.S. Triangular Plate For Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 15Mm Nominal Bore 17.16A 2.00 Each 261.85 251.38 502.76 Sanitary Fixtures & Accessories : I 9 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. Dsr-17.73.2 1.00 Each 531.69 510.43 510.43 10 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. Dsr-18.65 1.00 Each 83.58 80.24 80.24 11 Providing And Fixing C.P. Brass Ablution Health Faucet Assembly With 1.0 M Long Braided Pvc Hose With Mounting Bracket Fixed On Wall Complete.[For Ewc]-Make-Jaquar Ald565 Mr 2.00 Each 1705.00 1636.80 3273.60 12 Providing And Fixing C.P. Brass Two-Way Angle Valve For Ewc Points & For Fixing Ablution Health Faucet Of Approved Quality Conforming To Is:8931. 15 Mm Nominal Bore-Essco Sqt 526A Mr 2.00 Each 1335.00 1281.60 2563.20 1 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion . (I) Single Socketed Pipes. A) 110Mm Diameter 12.41.2 31.30 Mtr 283.04 271.72 8504.80 2 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement,Punning,Rounding The Edges And Making And Finishing The Outlet Complete. A) 110Mm 12.22 7.00 Nos. 223.68 214.73 1503.13 3 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. A) 110Mm 12.43.2 20.00 Nos. 278.47 267.33 5346.54 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I)Single Socketed Pipes. 110 Mm Diameter 12.41.2 Rm. 283.04 271.72 5 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Dsr-12.44 8.00 Nos. 41.02 39.38 315.06 6 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Nsr 20.00 Rm. 485.00 465.60 9312.00 B) 90Mm Dia P.V.C. Pipe Nsr 25.00 Rm. 390.00 374.40 9360.00 6 Providing & Fixing Upvc Floor Trap Of Self Cleansing Design With Cp Jali Complete In All Respects. (Make : Supreme / Finolex / Prince) P-Trap Type Floor Trap 110 X 90 Mm Nsr 12.00 No. 195.00 187.20 2246.40 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110X110X110 Mm Nsr 2.00 No. 280.00 268.80 537.60 110X110X90 Mm Nsr 2.00 No. 200.00 192.00 384.00 Bend 110 Mm Nsr 2.00 No. 170.00 163.20 326.40 Soil Waste & Vent Pipes And Fittings - Ii 90 Mm Nsr 2.00 No. 160.00 153.60 307.20 1 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.Lls Etc. (Internal Work) I) Exposed On Wall A) 32Mm Nominal Dia Pipe 18.9.4 30.00 Rm. 328.94 315.78 9473.44 3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Outer Dia Pipes 18.7.3 20.00 Rm. 301.15 289.11 5782.13 4 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work Including Cutting Chases And Making Good The Walls Etc. A) 15Mm Dia Nominal Outer Dia Pipes 18.8.1 70.00 Rm. 373.34 358.40 25088.28 B) 20Mm Dia Nominal Outer Dia Pipes 18.8.2 20.00 Rm. 403.19 387.06 7741.18 C) 25Mm Dia Nominal Outer Dia Pipes 18.8.3 Rm. 470.42 451.60 5 Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps Including Cutting & Making Good The Walls Etc. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Bore (Medium Duty) Dsr-18.10.3 20.00 Rm. 413.76 397.21 7944.21 Ii) Concealed Pipe Including Painting With Anticorrosive Bitumatic Paint, Cutting Chases And Making Good The Wall. A) 15Mm Dia Nominal Bore Dsr-18.11.1 15.00 Rm. 435.32 417.91 6268.65 2 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. A) 15Mm Dia Nominal Bore. Dsr-18.38.1 15.00 Rm. 14.55 13.97 209.51 B) 25Mm Dia Nominal Bore. Dsr-18.38.3 10.00 Rm. 22.69 21.78 217.79 2 Providing And Fixing 45 Cm Long Unplasticised Pvc Connection Pipe With Brass Unions. A) 15Mm Nominal Bore Dsr18.21.2.1 4.00 Nos. 73.31 70.38 281.51 5 Providing & Fixing Cp Brass Bib Cock Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.49.1 7.00 Nos. 380.09 364.88 2554.19 6 Providing & Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. A) 15Mm Nominal Bore 18.51.1 7.00 Nos. 599.19 575.22 4026.57 7 Providing & Fixing C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.53.1 14.00 Nos. 430.71 413.48 5788.75 8 Providing And Fixing Gun Metal Gate Valve With Wheel Of Approved Quality. A) 25Mm Dia Nominal Bore 18.17.1 2.00 Each 466.78 448.11 896.23 B) 32Mm Dia Nominal Bore 18.17.2 1.00 Each 517.18 496.50 496.50 C) 50Mm Dia Nominal Bore 18.17.4 Each 769.96 739.16 Water Supply Pipes And Fittings - Iii 9 Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 20Mm Dia Nominal Bore 18.18.2 1.00 Each 346.86 332.99 332.99 A) 25 Mm Nominal Bore 18.18.3 2.00 Nos. 348.03 334.10 668.21 10 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 18.48 A) Circular Tank 18.48 2500.00 Ltrs 8.25 7.92 19799.33 11 Providing And Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50Cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size) As Per Direction Of Engineerin-Charge And Finished Smooth. 8.10 Granite Stone Of Approved Shade Dsr-8.10.2 1.08 Sqm. 3038.79 2917.23 3150.61 1 Providing & Fixing Soil, Waste And Vent Pipes. A) 100Mm Dia Centrifugally Cast Iron S & S Pipe. Dsr17.35.1.2 6.00 Rm. 885.53 850.11 5100.67 2 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes & Fitting Of Diameters. A) 100Mm Dsr-17.58.1 2.00 Each 466.86 448.18 896.37 3 Providing & Fixing M.S. Holder Bat Clamps Of Approved Design To Sand Cast Iron/Centrifugally Cast (Spun) Iron S & S Pipe Embeded In & Including Cement Concrete Blocks 10X10X10Cm. Of 1:2:4 Mix (1 Cement : 2 Coarse : 4 Graded Stone Aggregate 20Mm Nominal Size). Including Cost Of Cutting Holes & Making Good The Walls Etc. A) For 100Mm Dia Pipe. Dsr-17.37.1 2.00 Each 272.13 261.24 522.49 4 Providing & Fixing Cast Iron Trap Of Self Cleansing Design With Or Without Ventarm Complete, Including Cost Of Cutting & Making Good The Walls & Floors. A) 100Mm Inlet & 75Mm Outlet. Dsr17.60.2.1 1.00 No. 1481.31 1422.06 1422.06 5 Providing & Fixing Cast Iron Coller. A) 100Mm Dia. Dsr17.57.1.2 2.00 No. 384.85 369.46 738.91 6 Providing And Fixing Plain Cast Iron S & S Sanitary Bend. A) 100Mm Dsr17.39.1.2 2.00 Nos. 427.52 410.42 820.84 1 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Mr 7.50 M 485.00 465.60 3492.00 2 Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber With F.P.S. Bricks Of Class Designation 75 And Water Tight C.I. Cover With Frame Of 300 X 300Mm. Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design. A) 150 X 100 Mm. Size P Type With Sewer Bricks Conforming To Is : 4885 Dsr-19.4.2.1 1.00 Nos 2050.58 1968.56 1968.56 Soil Waste & Vent Pipes And Fittings - Ii Schedule Of Quantities For Internal Sewerage System - Iv 3 Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Rcc Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size) Inside Plastering 12Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design 19.7 Inside Size 90X80Cms And 45Cms Deep Including Ci Cover With Frame (Light Duty) 455X610Mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15Kg). 19.7.1 With Fps Bricks Of Class Designation 150 Dsr-19.7.1.1 1.00 Each 9577.59 9194.49 9194.49 External Sewerage Works 1 Excavating Trenches In All Kind Of Soil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mm Diameter 2.10.1.2 20.00 Rm 264.10 253.54 5070.79 2 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. 160Mm Dia Under Floor (For External Sewer) Nsr 20.00 Metre 1190.00 1142.40 22848.00 3 Constructing Brick Masonry Manhole With F.P.S. Bricks In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Rcc Top Slab With 1 : 2 : 4 Mix (1 Cement : 2 Coarse Sand : 4 Grade Stone Aggregate 20Mm Nominal Size); Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1Cement 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Finishd With A Floating Coat Of Neat Cement Complete As Per Standard Design Inside Size 90 X 80 Cm & 45 Cm Deep Including Ci Cover With Frame (Light Duty) 455 X 610 Mm Internal Dimension Total Wt. Of Cover & Frame To Be Not Less Than 38 Kg (Wt. Of Cover 23 Kg And Wt. Of Frame 15 Kg) 19.7.1.1 3.00 Nos 9577.59 9194.49 27583.46 4 Extra For Depth For Manhole With F.P.S. Bricks Size 90 X 80 Cm 19.8.1.1 0.30 Rm 6618.83 6354.07 1906.22 5 Providing M.S. Foot Rests Including Fixing In Manholes With 20*20*10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20 X 20 Mm Square Bar 19.15.1 3.00 Nos 408.51 392.17 1176.51 6 Providing And Fixing Square Mouth S.W. Gully Trap Grade `A Complete With C.I. Grating Brick Masonry Chamber With F.P.S Bricks And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 180 X 150 Mm. Size P Type 19.4.3.1 2.00 Nos 2101.54 2017.48 4034.96 7 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 19.32.1 1.00 Nos 20145.75 19339.92 19339.92 8 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr-19.15.1 8.00 Nos. 408.51 392.17 3137.37 9 Providing And Fixing S.C.I. Tee 150 Mm At The Inlet And Outlet Of Septic Tank. Dsr-7087 2.00 Nos. 621.00 596.16 1192.32 10 Providing And Fixing Soil, Waste And Vent Pipes:75 Mm Diameter Sand Cast Iron S&S Pipe As Per Is: 1729 Dsr17.35.2.1 3.00 Rmt. 783.54 752.19 2256.58 11 Providing & Fixing Of 75Mm Dia Sand Cast Iron S&S As Per Is - 1729 Terminal Guard. Dsr17.56.2.1 2.00 Nos. 255.52 245.30 490.59 12 Providing & Fixing 75Mm Plane Sand Cast Iron S&S Bend Of Required Drgtee. Dsr17.39.2.1 2.00 Nos. 282.18 270.89 541.78 13 Providing Lead Caulked Joints To Sand Cast Iron/ Cetrifugally Cast (Squn) Irons Pipes & Fitting Of 50 Mm Dia Dsr-17.58.2 2.00 Nos. 394.67 378.89 757.77 14 Providing And Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality.M.D. -10- Circular Shape 500Mm Internal Diameter Dsr19.19.2.2 2.00 Nos. 879.42 844.24 1688.49 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.10.3 51.00 Each 1115.37 1070.76 54608.68 2 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.11 4.00 Each 1187.60 1140.10 4560.39 3 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Dsr 1.21.1 17.00 Metre 97.32 93.43 1588.26 4 Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Dsr 1.14.1 650.00 Metre 177.15 170.07 110542.86 5 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Dsr 1.14.2 188.00 Metre 285.12 273.71 51457.72 6 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Dsr 1.14.3 202.00 Metre 253.94 243.79 49244.67 7 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Dsr 1.14.4 105.00 Metre 333.78 320.42 33644.59 8 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required Dsr 1.32 22.00 Each 445.54 427.72 9409.83 9 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required Dsr 1.34 15.00 Each 99.60 95.62 1434.25 Electrical Works 10 Installation ,Testing, Commissioning Of Wall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Ls/Cfl/Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. Dsr 1.35 1.00 Each 90.48 86.86 86.86 11 Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Smd Type Of Following Body Material With Pmma And Prismatic Diffuser And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -50C To 400C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.≥0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K /4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Colour Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminium Body Including Trim 18 Watt Mr 19.00 Each 700.00 672.00 12768.00 12 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required Dsr-5.4 3.00 Each 5681.03 5453.79 16361.37 13 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 55.00 Metre 109.48 105.11 5780.78 14 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A) Single Pole Dsr-2.10.1 9.00 Each 194.64 186.85 1681.68 15 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 6 Way (4 + 12), Double Door Dsr-2.3.1 2.00 Each 1677.24 1610.15 3220.30 16 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 4 Way (4 + 12), Double Door Dsr-2.4.1 1.00 Each 3110.42 2986.01 2986.01 17 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Dsr-2.10.3 2.00 Each 498.76 478.81 957.62 16 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required Dsr 1.45 10.00 Each 257.74 247.43 2474.35 17 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 10.00 Each 280.55 269.33 2693.32 18 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep Dsr-1.50.1 7.00 Each 342.14 328.45 2299.17 19 Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes Dsr-1.51 7.00 Each 157.38 151.09 1057.62 20 Supply, Installation, Testing And Commissioning Of Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Metal( Aluminium Alloy) Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Steel/Al Body Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum As Below, 350 Rpm (Tolerance As Per Is : 374-2019), Thd (Total Harmonic Distortion) Less Than 10%, Suitable For Operation With Regulator For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 0C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Ceiling Fan Compliant To Is 374:2019 Fan I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. 9.2.3 10.00 Each 2075.64 1992.62 19926.18 21 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed By The Engineer-Incharge ,Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size 10 Sqmm X 2 Core Mr 164.00 Rm 410.34 393.93 64603.77 22 Supply & Fixing Of 225/230Mm Sweep Ventilating (Light Duty) Exhaust Fan Complete With Metallic Blade (Steel Bird Guard Protector /Copper Motor For High Air Suction Performance /Capacitor Etc.), Noise Level : (45 - 50) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. Mr 7.00 Each 1665.00 1598.40 11188.80 23 Cost For Murals Work 32.40 Sqm 5850.00 5616.00 181958.40 24 Cost For Solar Street Light With 7M Pole Complete 15.00 Nos 22600.00 21696.00 325440.00 25 Cost For C.C. Bench 12.00 Nos 10000.00 9600.00 115200.00 26 Cost For Dustbin 6.00 Nos 4500.00 4320.00 25920.00 1. Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Levelling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or / And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure).. (Horti) 2.1 159.24 Cum 74.51 71.53 11389.98 2 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 5 Km Lead Complete (Earth Measured In Stacks Will Be Reduced By 20% For Payment). (Horti) 2.2 79.62 Cum 491.88 472.21 37597.13 Horticulture 3 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Upto 5 Km Lead Complete (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 20 Mm (Horti) 2.4.1 106.16 Cum 242.46 232.76 24709.88 4 Spreading Of Sludge, Dump Manure And / Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And / Or Good Earth To Be Paid Separately). (Horti) 2.8 159.24 Cum 49.94 47.94 7634.64 5 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge (Horti) 2.9 159.24 Cum 34.87 33.47 5330.39 6 Grassing With Selection No.1 Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms A Thick Lawn, Free From Weeds And Fit For Mowing Including Supplying Good Earth, If Needed (The Good Earth Shall Be Paid For Separately). In Rows 5 Cm Apart In Both Directions. (Horti) 2.10.1 530.80 Sqm 16.89 16.21 8604.46 7 Providing And Displaying Of Aglaonema Silver Queen Having 30 Cm To 45 Cm. Ht. With 12 To 15 Leaves, Multi Suckers, Fresh And Healthy Leaves, Well Developed In 25 Cm Dia Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.8 60.00 Each 154.50 148.32 8899.22 (Horti) Dsr 3.8 8 Providing And Displaying Of Aglaonema Dove Variety Having Ht. 30 Cm To 45 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.4 75.00 Each 77.42 74.32 5574.03 (Horti) Dsr 3.4 9 Providing And Displaying Of Aglaonema Marentifolium Variety Having Ht. 23 Cm To 30 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy With Colorful Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.10 50.00 Each 64.54 61.96 3097.83 (Horti) Dsr 3.10 10 Providing And Displaying Of Chamaedorea Elegans Palm Having Ht. 60 Cm To 75 Cm, Well Developed With Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.26 50.00 Each 102.70 98.59 4929.51 (Horti) Dsr 3.26 11 Providing And Displaying Of Croton Baby Golden Variety Having Ht.30 Cm And Above, Well Developed With Full Of Fresh And Healthy Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.28 150.00 Each 39.11 37.55 5632.42 (Horti) Dsr 3.28 12 Providing And Displaying Of Croton Golden (Broad Leaves) Having Ht. 60 Cm To 75 Cm With 3 To 4 Branches, Well Developed, Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.32 150.00 Each 53.81 51.65 7748.01 (Horti) Dsr 3.32 13 Providing And Displaying Of Dieffenbachia Tropic-Snow Having Ht. 60 Cm & Above With 8 - 10 Leaves, Well Developed, Fresh & Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.40 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.40 14 Providing And Displaying Of Dieffenbachia Mosaic Having Ht. 30Cm To 45 Cm With 10-12 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.41 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.41 15 Providing And Displaying Dianthus In Different Colour Well Developed With Fresh & Healthy Foliage 30 Cm Ht., In Full Bloom With Stacking In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.29 50.00 Each 51.79 49.72 2486.05 (Horti) Dsr 4.29 16 Providing And Displaying Gazania Hybrid In Different Colour Well Developed With Fresh & Healthy Foliage With Full Bloom In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-Incharge. (Horti) 4.31 150.00 Each 61.63 59.16 8874.49 (Horti) Dsr 4.31 17 Providing And Displaying Gaillardia Double Hybrid Variety Well Developed 30 To 45 Cm Ht 20 To 30 Fresh & Healthy Flower With Green Painted Bamboo Stick In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.75 120.00 Each 51.85 49.78 5973.11 (Horti) Dsr 4.75 18 Providing And Stacking Of Plant Mogra Of Height 25 To 30 Cm., 2 To 3 Branch In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.88 100.00 Each 44.03 42.27 4226.60 (Horti) Dsr 4.88 19 Providing And Stacking Of Plant Canna Dwarf Of Height 25 To 30 Cm., 2 To 3 Suckers In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.89 100.00 Each 34.25 32.88 3287.87 (Horti) Dsr 4.89 20 Bush Rose In Different Colour 2 To 3 Healthy Branch 30 Cm And Above Ht. Well Developed With 8 Or More Flowers / Flower Buds In 20 Cm Earthen Pot /Plastic Pot As Per Direction Of The Officer-Incharge. (Horti) 4.90 100.00 Each 24.47 23.49 2349.13 (Horti) Dsr 4.90 21 Providing And Displaying Budded Rose (H.T. Variety) 3 To 4 Healthy Branch 30 Cm And Above Ht. Well Developed With One And Above Flower Plant In 20 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.91 100.00 Each 31.29 30.04 3003.96 (Horti) Dsr 4.91 22 Providing And Displaying Standard Rose (H.T. Variety) 3 To 4 Healthy Branch 90 Cm And Above Ht. Well Developed With One And Above Flowers In 25 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.93 75.00 Each 143.77 138.02 10351.28 (Horti) Dsr 4.93 23 Providing And Stacking Of Plumeria Rubra Of Height 120-150 Cm. With 3-4 Branches And Thick Stem In Big Size Hdpe Bags As Per Direction Of The Officer-In-Charge. (Horti) 7.72 75.00 Each 381.60 366.34 27475.20 (Horti) Dsr 7.72 24 Providing And Stacking Of Polyalthia Longifolia (Ashok) Of Height 180-195 Cm. In Gunny Bag Of Size 30 Cm As Per Direction Of The Officer-Incharge. (Horti) 7.75 75.00 Each 95.40 91.58 6868.80 (Horti) Dsr 7.75 25 Providing And Stacking Of Saraca Indica (Sita Ashok) Of Height 105-120 Cm. In Big Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge. (Horti) 7.80 75.00 Each 76.32 73.27 5495.04 (Horti) Dsr 7.80 26 Providing And Stacking Of Terminalia Arjuna Of Height 150-165 Cm. In Big Polybags Of Size 25 Cm As Per Direction Of The Officerin-Charge. (Horti) 7.88 75.00 Each 57.24 54.95 4121.28 (Horti) Dsr 7.88 27 Providing And Stacking Of Calliandra, Emarginata Of Height 45-60 Cm. In Earthen Pot Of Size 20 Cm As Per Direction Of The Officer-Incharge. (Horti) 8.5 150.00 Each 33.39 32.05 4808.16 (Horti) Dsr 8.5 28 Providing And Stacking Of Nerium Oleander (Kaner) Of Height 60- 75 Cm. With 5-6 Branches In Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
15.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
16.
Educational and Research Institute #11316829 AOC
Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Construction; Construction; Comprehensive Maintenance Contract (Cmc); Not Applicable; Yes - Providing And Laying Of Rcc Platform To Raised Flooring With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Aggregate : 4 Aggregate ) With Specific Area As Per Required And As Per Direction Of Site In Charge , Supplying, Fitting And Fixing 8Mm Thick Laminated Wooden Flooring Work Conforming To En13329:2006 With Plank Size Not Iess Than 1200 Mm X 190 Mm (With Unilin/Tongue-Groove Locking Arrangement) Having 0.2Mm Thick Top Abrasive Layer Over A Decorative Layer Followed By A High-Density Fibreboard (Hdf) Having Density > 850 Kg/M3 Substrate Core Over A Resin Saturated Backing Layer And Installing Through Unilin Or Tongue- Groove System (Having Locking Strength Not Less Than 1000 Kg/M) Over A 2 Mm Thick Under Layer Polyurethane Foam On Polythene Sheet 250 Micron, Over A Smooth, Flat, Hard Subfloor Free From Moisture (< 8%), Grease Etc. Complete In All Respect With Requisite Accessories Like End Profile, Transition Profile, Reducer T Profile Etc. Wherever Required And Preparation Of Base Including All Other Incidental Works As Per Direction & Satisfaction Of Engineer In Charge. Cost Of Laminate Floor Accessories Only (Skirting ,End Edge, T- Moulding, Reducer) Shall Have To Be Added Separately, Wherever Required As Directed By Engineer In Charge In Approved Shade & Colour As Per Drawing Specification ( Including All Lead And Lift )(Basic Rate :-Rs 180/- Per Sft) , Supplying Laminate Floor Accessories (Skirting, End Edge, T Moulding Reducer ) To 8Mm Thick Laminated Wooden Flooring Work Conforming To En13329:2006 With Plank Size Not Iess Than 1200Mmx 190 Mm (With Unilin/Tongue-Groove Locking Arrangement) Having 0.2Mm Thick Top Abrasive Layer Over A Decorative Layer Followed By A High-Density Fiberboard (Hdf) Having Density > 840 Kg/M3 Substrate Core Over A Rasin Saturated Backing Layer And Installing Through Unilin Or Tongue- Groove System (Having Locking Strength Not Less Than 1000 Kg/M) Over A 2 Mm Thk Under Layer Polyurethane Foam On Polythene Sheet 250 , Providing And Fixing Wall Panelling With Wpc Luvar Or Fluter Panel With 12 Mm Thick , Approved Colour , Pattern , Design , Shade, Fixing With Required 12 Mm Ply For Support As Per Required Area And As Per Direction Of Site In Charge , Providing And Fixing 15 Mm Thick Densified Tegular Edged Eco Friendly Light Weight Calcium Silicate False Ceiling Tiles Of Approved Texture Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections (Galvanising @ 120 Grams Per Sqm Including Both Side) Consisting Of Main T Runner Suitably Spaced At Joints To Get Required Length And Of Size 24X38 Mm Made From 0.33 Mm Thick (Minimum) Sheet, Spaced 1200 Mm Centre To Centre, And Cross T Of Size 24X28 Mm Made Out Of 0.33 Mm (Minimum) Sheet, 1200 Mm Long Spaced Between Maint At 600 Mm Centre To Centre To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24 X28 Mm Made Of 0.33 Mm Thick (Minimum) Sheet To Be Inter Locked At Middle Of The 1200X 600 Mm Panel To From Grid Of Size 600X600 Mm, Resting On Periphery Walls /Partitions On A Perimeter Wall Angle Pre-Coated Steel Of Size(24X24x3000 Mm Made Of 0.40 Mm Thick (Minimum) Sheet With The Help Of Rawl Plugs At 450 Mm Centre To Centre With 25 Mm Long Dry Wall Screws @ 230 Mm Interval And Laying 15 Mm Thick Densified Edges Calcium Silicate Ceiling Tiles Of Approved Texture In The Grid, Including, Cutting/ Making Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc., Wherever Required. , Providing And Fixing Electrical Work For Conference Room Including Wiring Inside Room Floor And Provision For Ac And Celling Light 600 X 600 Roof 36 Watt With Switches And Socket Power , And Underground Wiring With In Room As Per Required Including 2.5 To 6Mm Copper Wire As Where Required , Modular Switches And Power Socket With 4 Nos Wall Fan , Electrical Wiring With Room Complete As Per Direction Of Site In Charge , Providing And Fixing Cupboard Shutter With 19 Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2 Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges (Hydraulic Type) Etc. Complete As Per Direction Of Engineer-In-Charge. (Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately) , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. , Providing And Fixing 18 Mm Thick Plywood For Extended Floor Area As Per Required Size With Proper Fixing With Nails And Fastner On Floor Or Wall As Per Direction , Providing And Fixing Computer Table For Lab Using 19 Mm Thick Hdmr Board With 1 Mm Thick Top Laminate With Required Lenth 5X.075X0.9 Mtr With Partiton Every 900 Mm Both Side 1Mm Laminate , With Wooden Stand For Foot Rest, And Fixing With Fastner, Nail , Edge Bending 19Mm Tape Matching Colour , Rawl,Plug, Stright With Proper Fixing As Per Direction Of Site In Charge, , Removing And Re Fixing Wooden Door As Per Required Size With Change Of Ss Hinges Fixing 35Mm Thick Screw With Fixig Margin As Per Required Area As Per Direction Of Site In Charge , Any Other Work Paid As Per Civil 2023 Dsr Actual Rate .. And As Per Cpwd Rule,Note: The Payment Of Dsr23 Items (Which Are Inclusive Of Gst) Shall Beregulated As Below:Rate Of Dsr23 Items & 27.0 Additional Miscellaneousitems I/C Gst = X
Contract Date: Ref. Documents Contract Value : 39.65 Lakh
Boards / Undertakings / PSU No of Bidders 3
18.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
19.
Railways #11302167 AOC
Supply Of supply of cnc led machine lights. , supply of cnc led machine lights heavy-duty type for cnc machine area illumination, specif cally designed for reliable operation in harsh industrial environments involving continuous exposure to cool ant, oil mist, metal chips, dust, humidity, and high vibration, ensuring consistent illumination, durability, an d long service life. the make & model shall be similar to model no: cr-gmll-24-d-30w of craftech, phoenix , rittal or equivalent. construction: 1.enclosure material: borosilicate glass (minimum 4.2 mm thick). 2.ip r ating: minimum ip67 (ip68 preferred) as per is/iec 60529 for the model or design. electrical: 1.rated power 30w (+/-10%). 2.input voltage: direct 24 v dc & suitable to operate through external smps adapter/driver 3.polarity protection: reverse polarity safe. 4. cable length: minimum 2 meter oil resistant flexible cable . o ptical: 1.led type: lm-80 approved, high-quality industrial leds (e.g., osram / equivalent). 2.colour tempe rature: 6500 k +/- 500 k. 3.cri: ≥ 80. 4.luminaire efficacy: ≥ 110 lm/w (system efficacy, not led chip only ). 5.glare-free . 6.operating temperature: -20 degree c to +65 degree c. document & test report: 1.ip67/i p68 test certificate- shall be furnished along with offer . 2.technical datasheet shall be furnished along with offer. 3.manufacturers routine test certificate covering optical & electrical shall be furnished along with th e material. authorization: oem or oem authorized dealers only shall quote & shall submit authorized dealer ship certificate in case of dealer from oem. [ warranty period: 12 months after the date of delivery ] ]
Contract Date: Jun 17, 2026 Contract Value : 1.69 Lakh
Government Departments No of Bidders 1
20.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Contract Date: Ref. Documents Contract Value : 78.40 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
22.
Housing Urban and Rular Development #11286216 AOC
Tender For Construction Of New Primary Health Center (Phc New Bldg) At Perumalmalai H/O Adukkam, Kodaikanal Block.; 2 Clearing lightjungle vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. 4 Supplying and filling in foundations and basement with fillingM sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications. 5 Plain Cement Concrete 1 : 4 :8 ( one part of cement, four parts of sand and eight parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. 6 Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. 7 Supplying and filling of good earth filling locally available earth transported from the outside including consolidation,leveling specifiedin layers of not exceeding 200 mm thick., etc. complete. 8 Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification.(Payment for centering shall be given after the concrete is laid). 9 Upto Basement 10 Ground Floor 11 First Floor 12 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1m3 13 Foundation & Basement 14 Ground Floor 15 First Floor 16 Steel - Fe 500D : Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers. 17 Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 83/4 x 41/4 X2 3/4 for foundation and basement including curing etc., complete complying with standard specification. Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge. 18 Foundation basement 19 Ground floor 20 First floor 21 Brick partition walls of 11.50cm thickness using best quality Country bricks of size 83/4 x 41/4 X2 3/4in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 22 Ground Floor 23 First Floor 24 PLASTERING WORK 25 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The Surface shall then be allowed to dry for atleast 48 hours.It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface.Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete].The Putty shoule be got approved by the Executive Engineer before use on work. 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and ThreeM.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent andas directed. 28 FLOORING AND DADOOING 29 Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic Cost-Rs.776/sq.m 30 Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic cost-Rs.464/sq.m 31 Dadooing the walls with colouredDadooing Ceramic tiles of size 150mm x 150mm x 6mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surfacein all floors at the rate of 0.40 Kg /Sqm etc. complete. 32 Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 33 Providing, fabricating and fixing M.S. grillsWindows,and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer. 34 S.S Handrail 35 Manufacturing,supplying and fixing of stainless steel handrails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete. 36 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 37 Supply and Fabrication of UPVC doorincluding cost and conveyance of all charges etc complete. 38 Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. 39 UPVC Windowsupplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sectionwith wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plainglass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and shouldhave key lockable action, security protective hinges, strong lockingsystems and as per sizefor arrestingnoise and energy loss. 40 UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free , the profile are multi chambered sections withwall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work. 41 PAINTING WORK 42 Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications. 43 Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). 44 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 45 Weathering Course Concrete using best quality broken brick jelly of 20 mm uniform gauge in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jiggery water etc. complete complying with standard specifications and as directed 46 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 47 Plumbing Work 48 Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap withseat cover, supplyingnon corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L -brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, groutingwith cement concrete 1:2:4 mix, using 20mm size stone jelly,restoring the damaged portion to their original condition using required materials,fixing the water closet to perfect level,alignment,testingetc.complete. 49 Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofwhite coloured vitreous china under counterRegular rectangular wash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors- toilets. Wash Basin 50 Supply & Fixingat sitein position 15mm dia C.P brass BIB COCKS long body with wall flangeincludingcuttingandmakinggoodthe wallswhereverrequired 51 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 52 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 53 Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D) 54 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 55 a) 40mm dia. 6kg class PVC pipes. 56 b) 50mm dia. 6kg class PVC pipes. 57 c) 75mm dia. 6kg class PVC pipes. 58 d) 110mm dia. 6kg class PVC pipes. 59 Supplying and fixing in position cost iron Nahini / Floor trap with Stainless steel grating / PVC nahini / Floor Trap with PVC Grating type of size 100 x 75 / 75 x 50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1;2;5 (One lime two sand and five aggregate ) brick jelly 40mm and finishing with cm 1;3(One cement and three sand) including dismantling masonary wherever found necessary and making good to the original condition and giving connections to the cast iron pipe etc, complete complying with standard specififcation and as directed by the departmental Officers. 60 Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc.,complete. 61 b).110mm dia. 4kg class pipes. 62 Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and varietyof various size confirming to ISS andincluding necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 63 110mm dia 64 Supplying and fixing in position of the following dia PVC specials such asPVC vent Cowl etc.,of approved quality and varietyof various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 65 a)75mm Dia 66 b)110mm Dia 67 PART-C - EXTERNAL DRAINAGE 68 Soil/ Waste Pipes 69 Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and varietyof various size confirminghaving ISI mark and providing leak proof joints including erection of below groundwith excavation and refilling etc.,and making connection to Manholes /Gully trap,wherever necessary and making chipping good portion to the original condition,complying with standard specification etc., complete. 70 160mm dia. 6kg class III-pipes. 71 Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface withProviding and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std.specification. 72 Supplying and Erection and construction of sewer chambers of required internal dimensions 600x600 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 600x600mm (clear opening)complete complying with standard specifications etc., 73 Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings,including all types of excavation, occur for pipe,filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing. 74 Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid ofcapacity of 2000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work)(TWAD- Pano:173) 75 provision for rainwater harvesting structure 76 Electrification 77 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) 78 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End 79 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End 80 Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.) 81 Supply and fixing of fancy glass shade and 7W / 9W LED bulb 82 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting 83 Supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch 84 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down 85 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall 86 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 87 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 88 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) 89 Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 24 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 90 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 91 Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipeconcealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of theconcealed portion with suitable colour 92 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. 93 Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitablecolour 94 Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitablecolour 95 Supply and run of 1 of No.8 SWG GI wire for earth connection 96 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earthconnection 97 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm 98 Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection with earth connection complete 99 Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only 100 Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing 101 Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection 102 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 103 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 104 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 105 Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 106 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 107 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 108 Septic Tank 109 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 110 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 111 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 112 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 113 REINFORCED CEMENT CONCRETE M25 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. 114 Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4 x 4-1/4 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 115 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed. 116 Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete. 117 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost). 118 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 119 Under Ground Sump 120 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 121 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 122 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 123 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 124 Reinforced Cement Concrete 1:11/2:3 (One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers 125 Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of Sand ),to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams,and Sun shades etc.to correct plane and l 126 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of 25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost) 127 Supplying and fixing in position C.I.Manhole covers (heavy duty) of various sizes of best approved quality and as per standard specificationsetc.,complete.0.6X0.6M Size etc., complete. 128 PVC mould CI steps for sump 129 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 130 Aluminium ladder for maintenance over the Roof top 131 Provision for lab interior 132 Tactile Flooring and Braille Sign Board 133 Provision for Sitting bench and Cubboard Arrangements 134 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Jun 13, 2026 Contract Value : 1.68 Crore
Local Bodies No of Bidders 2
23.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
24.
Law and Justice #11279308 AOC
Bids Are invited for Turnkey Project For Skill Development Lab At Various Place In Sws Chandrapur Providing Or Supplying Ceiling Tile For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Ceiling Lights For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Wall Painting For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Carpet For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Electrical Work For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Windows Curtain Work For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Vinyl Display Board For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Electric Fan For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Lifier With Sound System Set For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Mini Pottery Wheel Machine For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Diya Making Mould For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Student Chair For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Computer Table For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Disktop Computer With Graphic Desing And Cereartive Media For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Activity Work Table For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Furniture And Glass With Play Partition Or Acp Partition As Per Skill Lab Requirement For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Plumbing Zone For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Video And Photography Camera For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Beauty And Wellness For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Electric And Electronics Work Station For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Mobile And Computer Repairing Zone For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Tailoring Unit For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Carpentry And Woodcraft Workplace For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Screen Printing And Fabric Design Unit For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Food Production And Food Making Skills For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Agriculture And Organic Farming For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Communication And Public Speaking For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying 3D Printer For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Awareness Program And Demonstration Board For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Record Book System Set For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Trainer Service For 2 Years For Skill Development Lab At Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing Or Supplying Foldable Wheel Chair For Skill Development Lab At Nivasi School Bhivkund And Nivasi School Chimur Dist. Chandrapur - Sepcification Givenin Specification Documents , Providing And Installing Sliding Shutter Machinism For Protecting Of Interactive Panal At Bhivkund Dist Chandrapur - Sepcification Given In Specification Documents , Providing And Installing Sliding Shutter Machinism For Protecting Of Interactive Panal At Chimur Dist Chandrapur - Sepcification Given In Specification Documents , Providing And Installing Lifier With Sound System At Nivasi School Chimur Dist Chandrapur - Sepcification Givenin Specification Documents , Providing And Installing Lifier With Sound System At Nivasi School Bhivkund Dist Chandrapur - Sepcification Givenin Specification Documents , Providing And Installation Of 8 Tb Hdd Disk Drive For Cctv Survelance System At Nivasi School Chimur 1 Nivasi School Bhivkund 2 Rajura 1 Sindevahi 1 - Sepcification Givenin Specification Documents , Providing And Installation Of 32 Port Channel Nvr Video Recorder For Cctv Survelance System At Nivashi Bhivkund 2 Qty And Chimur 1 Qty - Sepcification Givenin Specification Documents , Providing And Installation Of 16 Port Channel Nvr Video Recorder For Cctv Survelance System At Sindevahi 1 Qty And Rajura 1 Qty - Sepcification Givenin Specification Documents , Providing And Installation Of 2 Mp Dome Camera For Cctv Survelance System At Chimur 4 Chimur 5 Sindewahi 12 - Sepcification Givenin Specification Documents , Providing And Installation Of 2 Mp Bullet Camera For Cctv Survelance System At Hostel Chimur 6 Nivshi School Chimur 17 Brahmpuri 8 Sindewahi 4 Chandrapur 8 Bhivkund 18 Rajura 16 - Sepcification Givenin Specification Documents , Providing And Installation Of Cable 305 Mt. Per Bundle For Cctv Survelance System At Chimur 2 Chimur 3 Brahmpuri 1 Sindewahi 3 Chandrapur 1 Bhivkund 3 Rajura 2 - Sepcification Givenin Specification Documents , Providing And Installation Of Hdmi Cable For Cctv Survelance System At Chimur 1 Chimur 2 Brahmpuri 1 Sindewahi 1 Chandrapur 1 Bhivkund 1 Rajura 1 - Sepcification Givenin Specification Documents , Providing And Installation Of Spike Guard For Cctv Survelance System At Chimur 1 Chimur 2 Brahmpuri 1 Sindewahi 1 Chandrapur 1 Bhivkund 1 Rajura 1 - Sepcification Givenin Specification Documents , Providing And Installation Of Wireless Mouse For Cctv Survelance System At Chimur 1 Chimur 2 Brahmpuri 1 Sindewahi 1 Chandrapur 1 Bhivkund 1 Rajura 1 - Sepcification Givenin Specification Documents , Providing And Installation Of Poe Switch 8 Port For Cctv Survelance System At Chimur 1 Chimur 3 Brahmpuri 1 Sindewahi 2 Chandrapur 1 Bhivkund 2 Rajura 2 - Sepcification Givenin Specification Documents , Providing And Installation Of Poe Switch 4 Port For Cctv Survelance System At Chimur 2 Bhivkund 2 - Sepcification Givenin Specification Documents , Providing And Installation Of 4U Rack Enclosure Networking Server Rack For Cctv Survelance System At Chimur 1 Chimur 2 Brahmpuri 1 Sindewahi 1 Chandrapur 1 Bhivkund - Sepcification Givenin Specification Documents , Providing And Installation Of 2U Rack Enclosure Networking Server Rack For Cctv Survelance System At Chimur 2 Bhivkund 2 - Sepcification Givenin Specification Documents , Providing And Installation Of Pvc Box For Cctv Survelance System At Chimur 8 Chimur 23 Brahmpuri 8 Sindewahi 16 Chandrapur 8 Bhivkund 19 Rajura 16 - Sepcification Givenin Specification Documents , Providing And Installation Of Television 32 Inch For Cctv Survelance System At Chimur 1 Brahmpuri 1 Sindewahi 1 Chandrapur 1 Rajura 1 Bhivkund 1 - Sepcification Givenin Specification Documents , Providing And Installation Of Television 55 Inch For Cctv Survelance System At Nivasi Bhivkund 1 - Sepcification Givenin Specification Documents Total Quantity : 2901
Contract Date: Ref. Documents Contract Value : 1.77 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
26.
Educational and Research Institute #11273270 Technical Bid
Tender For Civil Work At Mgsss, Ratanpura Block Rajgarh- 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 P.C.C. In Foundation Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:4 Coarse Sand :8 Gradeed Stone Aggregate 40 Mm Nominal Size). 4 Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Foundation And Plinth With Bricks Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) 5 Dpc:-Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required Excluding The Cost Of Centering, Shuttering And Reinforcement . M20 Grade Nominal Mix/Design Mix. 6 Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc. Good Soil Of Earth 7 Brick Work In Super Structure Upto Five Storey With Selected Bricks Of Class Designation 75 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10Mm. Wide 12Mm. Deep Complete In Cement Mortar 1:6. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Add Extra Over Item Of Brick Work With Class Designation 100 In Substitution Of Class Designation 75 : 8 Pillar Masonary :-Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And All Sides Are Free 9 Stone Kharanja: Rr Dry Stone Kharanja Under Floor 10 Lintel Beams:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 11 Slab & Beam:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 12 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. 13 Steel Reinforcement:-P/F Reinforcement For Rcc Work Including Straightening,Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Upto Floor Five Leve Tmt Bars (Conforming Of Relevent Is Code). 14 Door Frames:- Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M), Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Angle Iron (40X40X5Mm. @ 3 Kg/M) 15 Doors:-Providing And Fixing M.S. Sheet 1 Mm Thick Double Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint. Add Extra For Double Leaf Shutters 16 Glazed Window:Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13X3Mm, 10Cm. Long Embedded In Cement Concrete Block 15X10X10Cm. Of 1:3:6 (1Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :Partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] 17 Wire Gauge Supplying & Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150 Mm Distance. 18 Guard Bars: P&F Square Bars Or Other Flat Welded To Window/Ventilators Etc. 19 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 20 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab From 2001 To 5000 Sqcm 21 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish : 12Mm Thick. 22 External Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 20 Mm Thick 23 Plaster(Ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1 Cement: 3 Fine Sand) 24 Black Board : Plaster On New Surface On Wall In Cement Sand Mortar 1:3 Including Raking Of Joints Etc. Complete Fine Finish: 12 Mm Thick 25 Grading Roof For Water Proofing Treatment With Water Proffing Compound: Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) 26 Gola:- Providing Gola 75Mm X 75Mm In Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Stone Aggregate 10 Mm And Down Gauge) Including Finished With Cement Mortar 1:3(1 Cement: 2 Fine Sand) As Per Standard Design. 27 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: New Work (Two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. 28 Inernal Finishing: Distempering With Dry Distemper Of Approved Brand Shade ( Two Or More Coats ) Of Required Shade New Work , Over And Including Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 29 Exterior Finishing: Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 30 Painting On Doors, Windows & Ramp Raling :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). 31 Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 32 For Rain Water-P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 33 For Rain Water-P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110Mm Dia 34 Pipe Clip 110 Mm Dia 35 Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300Mm Confirming To Code Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). 36 Part B Electrical Work 37 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Short Point (Up To 3 Mtr.) 39 Medium Point (Up To 6 Mtr) 40 Long Point (Up To 10 Mtr) 41 Fan Point 42 Short Point (Up To 3 Mtr.) 43 Medium Point (Up To 6 Mtr) 44 Long Point (Up To 10 Mtr) 45 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsron Board 46 S&F Following Sizes (Dia.) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along With Isi Marked (Is:14768 P-Ii 2003) Accessories In Recessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Including Cutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 25 Mm 47 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 48 1 X 1.5 Sq. Mm 49 2 X 1.5 Sq. Mm 50 2 X 2.5 Sq. Mm 51 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6 A To 32 A Rating 52 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Metal Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 8 Way (8+2) 53 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Minimum Lumen Output 1300 Lm 54 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity >99.7 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6.0 Sq. Mm 4 Core 55 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 3 Star Rated (Service Value >=5.0 To 56 Providing & Fixing Of Isi Marked (Is:371) 6 Amp Surface Type 3 Pin Ceiling Rose With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screws Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 57 Providing & Fixing Of Isi Marked (Is:1258) Batten/Angle Lamp Holder With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 59 P & F 1.2 Mm Thick G. I. / M .S. Sheet Boxes Duly Finished With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes (Nominal Size) In Recessed/Surface As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 175Mm X 100Mm X 60Mm 60 P & F Paper Phenolic Resin Bonded Laminates Confirming To Is : 2036 - 1995 For Boxes/ Frames Including Making Holes For Switches Etc, With Brass Screws, Washers/ Zinc Plated Nut And Bolts As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3.0 Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
27.
Defence #11261891 AOC
Bids Are Invited For Superstructure Medium Living Shelter Mls Of Size 10 Point 44M X 6 Point 10M X 4 Point 75M Height With 1 Point 50M Wide Verandah At Front And Rear Side , Cement Opc 43 Grade Packed In Hdpe Bag Each 50 Kg Wt , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40Mm Graded , Coarse Aggregate 40 Comma 63 Mm Graded , Stone For Rr Masonry Less Than 6 Inch , Water Proofing Compound , Mild Steel Bars Of Size 10 Mm And Above Dia , Mild Steel Bars Of Size 6 To 8Mm Dia , Ms Binding Wire , Stone For Rr Masonry Less Than 9 Inch To 12 Inch , Pvc Pipes 75Mm Each 3 Mtr Long , Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick , White Cement , Peg Set Of Six Fitted With Galvanised Screws Along The Internal Surface Of The Walls In The Rooms , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long Comma Pre Coated Ms Pipe With Fancy Type Ends , Ceiling Rose Three Terminal Snow White , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Obliquw 76 , Pvc Flexible Conduit Pipe 15Mm Dia , Pvc Round Oblique Square Block , Exhaust Fan 230 Volts 300 Mm Sweep Plastic Body Alongwith Louvers And Complete Fittings , Fire Exitingusher Of 1Kg Capacity Of Dry Powder Type , Distribution Box 8 Way Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud , Mcb Spn 240 Volts 63 Amps , Mcb Sp 6 To 32 Amps , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 1 Point 5 Sqmm Single Core , Pvc Tape 19Mm Wide 5M Long , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 4 Sqmm Single Core , Pvc Casing Capping 1 Inch Medium Grade Snow White , Pvc Casing Capping Of Size 3 Oblique 4 Inch Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White ,Screw Full Thread 6X19 Mm , Pvc Switch Board Snow White Of Size 7 Inch X4 Inch For Socket And Switches , Pvc Switch Board Snow White Of Size 8 Inch X10 Inch For Main Switch Oblique Db , Pvc L Bend And T Junction Joint For Pvc Casing And Caping , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15A Comma 230V , Switch Socket Combination Snow White 5A Comma 230V , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5M Long , Service Cable Pvc Insulated Aluminium Conductor Comma 1100 Volt Grade Heavy Duty , Led Tuble Light Fittings 15W 230V Box Type 4 Feets With Crca Body Pre Coated White And Prewired For Led Tuble Complete , Led Bulk Head Fitting High Pressure Die Cast Aluminum Front Cover With Glass Cover With Specially Design Gasket With Led Lamp 10 Watts , Earthing Plate 600X600X6Mm Galvanised Steel Suitable For Gi Strip Fittings Comma Drilled With Two Nos Holes For 6 Mm Dia Near One Side , Ci Earthing Pit Cover Of Size 300X300X6Mm With Angle Iron Isa 20X20X3Mm Thick Ms Frame , Funnel Fitted With 20Mm Dia Gi Pipe 1 Point 5M Long , Gi Wire 4Mm Diameter , Charcoal , Salt Normal , Air Terminal Single Pointed Aluminium Rod 12Mm Dia And 300Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronzesize 75X75X25Mm Drilled And Screwed Including 3 Nos 8Mm Dia 25Mm Long Hexagonal Head Screw , Aluminium Strips 25X3Mm , Galvanised Iron Strip 32X6Mm , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Individual Standalone Plastic Body Smoke Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Individual Standalone Plastic Body Heat Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Fire Ball Extinguisher 1 Point 3 Kg With Suitable Provision For Wall Mounting And Capable Of Self Activating On Contact With Flames , Double Sleeping Bunk Dsb Complete All As Per Technical Specification Along With Foam Cum Coir Matress , Steel Bed Side Locker Of Size 1000Mm X 1520Mm X 450Mm Complete All As Per Technical Specification , Study Chair Of Size Length 56 Cm Comma Height 82 Cm And Width 56 Cm Comma Lacquered Finish With Arm Comma Seat And Back Cushion Comma Velvet Upholstery , Study Table Of Size 4 Ft X 2 Ft Wooden Top On Round Tube Structure With Three Drawers Unit , Looking Mirror Of Size Of Selected Quality Frameless Of Size 600 X 450 X 5 Mm , Water Dispenser Of 230 V 500 Watts Without Refrigerator With Normal Cold And Heating Capacity Of 5 Lts Oblique Hour With Storage Compartment And Auto Shut Off Facility , Portable Indoor Type High Quality Kero Heater Metal Body Ignites Type Of Continues Heating , Kassi With Handle , Black Steel Sr Shovel Spade Belcha , Plaster Trowel With Wooden Handle , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm , Plumb Bob Iron , Crow Bar 1 Point 5 Inch Dia 4 Feet Long , Hammer 1 Kg With Wooden Handle Durmut , Hammer 0 Point 5 Kg With Wooden Handle Durmut , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 Inch 305Mm , Sprit Level , Measuring Tape 30 Mtr Steel , Water Bucket Steel 13 Inch Dia , Picks Axes With Chisel And Point Ends Kudali 14 Cp Nominal Weight 3 Point 0 Kg , Lime Brush Best Quality , Painting Brush 100Mm , Hacksaw Frame Large With Blade 05 Nos , Galvanised Iron Pan Mortar Tasla Comma 18 Gauge 20 Inch Dia , Wooden Waterproof Plywood Thickness 12Mm , Nails Various Sizes , Rammer Earth With Handle Minimum Weight 5 Kg Without Handle , Tester For Electrician With Plastic Handle 150Mm , Electric Drill Machine Heavy Duty 500 Watt Electrical Backup With Battery And Charger , Drill Bits Hss 5Mm Comma 8Mm And 10Mm Dia For Electric Drill Machine , Electric Tile Cutting Machine With Interchangable Blades 05 Nos , Electrical Sheet Cutter Total Quantity : 4940
Contract Date: Ref. Documents Contract Value : 31.90 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 17
28.
Defence #11260970 AOC
Bids Are Invited For Supertructure Small Living Shelter Of Size 5 Point 22M X 6 Point 12M X 4 Point 75M Height With 1 Point 50M Wide Verandah At Front And Rear Side , Cement Opc 43 Grade Packed In Hdpe Bag Each 50 Kg , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40Mm Graded , Coarse Aggregate 40 To 63 Mm Graded , Stone For Rr Masonry Less Than 6 , Water Proofing Compound , Mild Steel Bars Of Size 10 Mm And Above Dia Conforming To Is 432 , Mild Steel Bars Of Size 6 To 8Mm Dia , Ms Binding Wire , Pvc Pipes 75 Mm Each 3 Mtr Long , Non Skit Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick , White Cement , Peg Set Of Six Fitted With Galvanised Screws Along The Internal Surface Of The Walls In The Rooms , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long Pre Coated Ms Pipe With Fancy Type End , Distribution Box 8 Way Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud , Mcb Spn 240 Volts 32 Amps , Mcb Sp 6 To 32 Amps , Pvc Tape 19Mm Wide 5M Long , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 1 Point 5 Sqmm Single Core Frls , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 2 Point 5 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 4 Sqmm Single Core , Pvc Casing Capping 1 Inch Medium Grade Snow White , Pvc Casing Capping Of Size 3 Oblique 4 Inch Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White , Led Tuble Light Fittings 15W 230V Box Type 4 Feets With Crca Body Pre Coated White And Prewired For Led Tuble Complete , Steel Screw Full Thread With Rawl Plug Plug Of Size 1 1Oblique 2 Inch Size , Pvc Switch Board Snow White Of Size 7 X 4 Inch For Socket And Switches , Pvc Switch Board Snow White Of Size 8 X1 Inch For Main Switch , Pvc L Bend And T Junction Joint For Pvc Casing And Caping , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15A Comma 230V , Switch Socket Combination Snow White 5A Comma 230V , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5M Long , Service Cable Pvc Insulated Aluminium Conductor 1100 Volt Grade Heavy Duty Served With Inner Sheathing Of Pvc Tap And Overall Pvc Sheathed In Service Connection 10 Sqmm 2 Core , Ceiling Rose Three Terminal Snow White , Led Bulk Head Fitting High Pressure Die Cast Aluminum Front Cover With Glass Cover With Specially Design Gasket With Led Lamp 10 Watts , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Oblique 76 , Pvc Flexible Conduit Pipe 15Mm Dia , Pvc Round Oblique Square Block , Exhaust Fan 230 Volts 300 Mm Sweep Plastic Body Alongwith Louvers And Complete Fittings , Fire Exitingusher Of 1Kg Capacity Of Dry Powder , Earthing Plate 600X600X6Mm Galvanised Steel Suitable For Gi Strip Fittings Drilled With Two Nos Holes For 6 Mm Dia Near One Side , Ci Earthing Pit Cover Of Size 300X300X6Mm With Angle Iron Isa 20X20X3Mm Thick Ms Frame , Funnel Fitted With 20Mm Dia Gi Pipe 1Point 5M Long , Gi Wire 4Mm Diameter , Charcoal , Salt Normal , Air Terminal Single Pointed Aluminium Rod 12Mm Dia And 300Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronzesize 75X75X25Mm Drilled And Screwed Including 3 Nos 8Mm Dia 25Mm Long Hexagonal Head Screw , Aluminium Strips 25X3Mm , Galvanised Iron Strip 32X6Mm , Funnel Fitted With 20Mm Dia Gi Pipe 1 Point 5M Long , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Individual Standalone Plastic Body Smoke Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Individual Standalone Plastic Body Heat Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Fire Ball Extinguisher 1 Point 3 Kg With Suitable Provision For Wall Mounting And Capable Of Self Activating On Contact With Flames , Double Sleeping Bunk Dsb Complete All As Per Technical Specification Along With Foam Cum Coir Matress , Steel Bed Side Locker Of Size 1000Mm X 1520Mm X 450Mm Complete All As Per Technical Specification , Study Chair Of Size Length 56 Cm Comma Height 82 Cm And Width 56 Cm Comma Lacquered Finish With Arm Comma Seat And Back Cushion , Study Table Of Size 900Mm X 600Mm X 760Mm Wih 18 Mm Thick Prelaminated Particle , Looking Mirror Of Size 18 X 4 Inch Fixed With 4 Mm Thick Ply Incl Fixing Arrangement , Water Dispenser Of 230 V 500 Watts Without Refrigerator With Normal Cold And Heating Capacity Of 5 Lts Oblique Hour With Storage Compartment And Auto Shut Off Facilit Toyotomi Automatic Kero Room Heater Comma Omni 230 , Plastic Dustbin Of Capacity 40 Ltrs , Kassi With Handle , Black Steel Sr Shovel Spade Belcha , Plaster Trowel With Wooden Handle , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm , Plumb Bob Iron , Crow Bar 1 Point 5 Inch Dia 4 Feet Long , Hammer 1 Kg With Wooden Handle Durmut , Hammer 0 Point 5 Kg With Wooden Handle Durmut , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 Inch 305Mm , Sprit Level , Measuring Tape 30 Mtr Steel , Water Bucket Steel 13 Inch Dia , Picks Axes With Chisel And Point Ends Kudali 14 Cp Nominal Weight 3 Point 0 Kg , Lime Brush Best Quality , Painting Brush 100Mm , Hacksaw Frame Large With Blade 05 Nos , Galvanised Iron Pan Mortar Tasla Comma 18 Gauge 20 Inch Dia , Wooden Waterproof Plywood Thickness 12Mm , Nails Various Sizes , Rammer Earth With Handle Minimum Weight 5 Kg Without Handle , Tester For Electrician With Plastic Handle 150Mm , Electric Drill Machine Heavy Duty 500 Watt Electrical Backup With Battery And Charger , Drill Bits Hss 5Mm Comma 8Mm And 10Mm Dia For Electric Drill Machine , Electric Tile Cutting Machine With Interchangable Blades 05 Nos , Electrical Sheet Cutter Machine With Blade , Puf Rivet Machine , Centre Punch 8Mm Dia Best Quality , Plumbing Tool Kit , Water Level Pipe 30 Mtr Lon Total Quantity : 1742
Contract Date: Ref. Documents Contract Value : 9.97 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 10
29.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
30.
Health and Family Welfare #11254887 AOC
Bids Are Invited For Condenser Blade - Material In Plastic Suitable For Split Ac 2 Ton Size 17Point5 , 4 Mfd Capacitor - Capacity Type 4 Mfd Material Type Copper Shape Type Round Connection Type Wired , Samsung Timer - Body Material In Plastic Voltage 120V In Refrigerator Samsung Timing Approx 9 Hours 40 Min Comp 12 Min Heater Product Capacity Above 250 Litres Of Double Door Refrigerator , White Wrapping Tape - Adhesive - Rubber Base Material - Pvc Type - Non Adhesive Suitable For Copper Clubbing Each Nos 15 Meters , Teflon Tapes - Material Poly Tetra Fluoro Ethylene Features Heat Resistance Each Nos 10 Meters , Cello Tape 2 Black - Colour Black Material Biaxially Oriented Polypropylene Uses Wrapping Of Ac Copper Pipes And Packing Purpose , Cotton Waste - Colour White , Danfoss Relay Set 20 Deep Freezer - Connector Type Through Hole Contact Type Normally Open Mounting Type Din Rail Mount Operation Mode Automatic , 80 By 100 Mfd Capacitor - Capacity 80 By 100 Mfd Voltage 275 Vac 50 Hz , Minus 20 Deep Freezer Square Type - Fan Type Square Voltage 220 V, 50 Hz Wattage 65 Watts Heat Sink Material Copper , Pin Remover Charging - Item Is Valve Core Remover Installer Material Type Copper Service Ports Is 1 By 4Inch And 5 By 16 Inch Sae Female Bypass Ports Is 1 By 4 Inch Sae Male , Thermostat Minus20 - Model Wpf 20 250 V 4 Of 6A 50 Or 60 Hz Suitable For Minus20 Deep Freezer Vertical , Relay Danfoss - 103N0021 25Ohm 463 220V 240V , Capacitor 4 Mfd - Capacity 4Mfd 280 V Ac 10000H Ki 8 50 Or 60 Hz Material Shape Round Type , Condenser Fan Blade For 2 Ton Llyod Ac - Material Plastic Suitable For Split Ac 2 Ton Size 17 Point 5 , Pinch Pliers - Color Multicolor Primary Material Ss , T Handle 10Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber , T Handle 12Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber , Sand Paper - Color Brown 80 Grit , 1 By 4Inch Ratchet - 3 By 16 Inch And 1By4 Inch Square X 1By2 Inch And 9By16 Inch Hex Ratcheting Refrigeration Wrench , Refrigerant Recovery Plier - 1By4 Sae Interface Material Ss , Allen Key Set In Inches - Item 10 Pack Of Allen Key Material High Grade Alloy , Cold Room Evaporator Fans - Make Hi Cool Model 4E 450S 230 V 50 Hz 1Point15a 155 Or 250W 1350 R By Min Axial Fan Motor Warranty 1 Year , 8 Mfd Capacitor - Body Material Metal, Connection Type Wired Voltage 440 Vac 50 Hz , Nose Pliers - Make Taparia Material Carbon Steel Handle Material Plastic Rubber Steel , Wire Cutter - Harden 7Inch Professional Electric Wire Cutter Stripper Made Of Zinc Alloy And Supports Wire Diameter Range 4 Mm Features Cut And Stripping Line Two-In-One Product Combined With Cut Line And Stripping Two-In-One Powerful And Durable Ergonomic Designed Handle Multipurpose Wire Stripper Under The Tangent Mouth Design Tangent Convenient Sharp And Durable Save Labor Force Spring Design Mached With A Length Of 47Mm Gun Mouth Convenient And Quick Efficient Adjustable Knob Wire Stripping Force Can Be Adjusted By The Knob Size To Avoid Excessive Damage To The Wire And Cable Ergonomic Handle According To The Human Body Design Feel Comfortable And Durable , Charging Line R32 - Make Value Material Brass 3Pc Charging Hose Suitable For R32 Gas Charging , Two Way Manifold Gauge With Box And Hose - Make Value Model No Vmg2 R410a 02 Pressure Range 30 500Psi Low 0 800Psi High Hose Red And Blue And Yellow 1By4inch 1By4inch 3X1pc , 46 Pcs Set - Make Stanly 46Pcs 1By4 Inch Drive Box End Socket Set Metric Ratchet Wrench Set With 4 To 14Mm Cr V Sockets S2 Bits Extension Bars Material Ss , Cylinder Key - Material Ss , Tourch For Butane Gas Cylinder - Make Clix Nozel Single , Swaging Tools - Swage For 1By4inch 5By16inch 3By8inch 1Byinch 5By8inch 3By4inch 7By8inch , Rough File With Handle - Make J K Thickness 3 Mm Material High Carbon Steel Width 12 Mm Length 100 Mm , Double End Spanner Set 6X32 Mm - Make Taparia Size 6Mm To 32 Mm Type End Type , T Set 13Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber , T Set 14Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber , Drain Line Spring - Length 30 Meters Material Steel Color Silver Packaging Size 30 Meters , Single Gauge High Side - Make Value Model Vmg 1S H Pressure 0To800 Psig Material Brass , Measuring Tape 5 Meters - Make Stanly Coating Tylon Blade Lengh 5 Meters Body Material Rugged Rubber , Expansion Valve For Cold Room - Make Model Erse 4C Body Machined Brass Bar Seat Brass Port Machined In Body Pin Stainless Steel Pushrod Stainless Steel Type Of Joints Knife Edge To Metal Connections Odf Copper Fittings Silver Soldered To Body Inlet Strainer No Strainer Suitable For R 22 Refrigerant , Condenser Motor - Make Llyod Model Ydk68 6Bl Kw68b Rpm 900 Rotation Ccw , Condenser Blade - Material Plastic Suitable For Split Ac 1Point5 Ton Size 16Inch , Capacitor 3 Mfd - Body Material Plastick Connection Type Wired Voltage 440 Vac 50 Hz Capacity 3Mfd Shape Round , Digital Temp Meter - Make Hitcahi Model No Hd 306 Humidity Range 0 To 100 Rh Temperature Range Minus20c To Plus200c) Warranty 1 Year , Samsung Heater - Uses Refrigerator Heater Size 14 , Timer - Model Td20 Csa Power 220V 50 Hz Number Of Terminals 4 , Condenser Fan Blade - Material Plastic Suitable For Split Ac 2 Ton Size 17Point5inch , Valve 3By8inch Hand Shut Off - One Side 1By4inch Male Flare Other Side 3By8inch Male Flare Material Fully Brass With Handle , Cylinder Valves - Model Cga 320 Type Handle Material Brass Outlet 1/4Inch , Condenser Motor - Ge Motor Cpn 2Az0 10To 090Coma 920 Rpm Cwse 1By5 Hp , Fan Blade - Material Aluminum Suitable For The Ge Motor Cpnto2az0 To10to090 Size 19Inch , Hand Cutter Blade Iron - Size 4Inch 107X1point0x16 Mm 4Inchx3by64inchx5by8inch 15300 Rpm Double Net Max Speed 80 Ms Metal Cutting Wheels , Adjustable Wrench 6Inch - Make Taparia With Rubber Grip Size 6Inch , Adjustable Wrench 8Inch - Make Taparia With Rubber Grip Size 8Inch , Adjustable Wrench 12Inch - Make Taparia With Rubber Grip Size 12Inch , Allenkey Set Mm - Item 10 Pack Of Allen Key Set Material High Grade Alloy , Flaring Tools Set With Box - 1 X Flaring Tool 1 X Inch Pipe Clamp 1 Xmetric Pipe Clamp 1 X Pipe Cutter 1 X Pipe Deburring Tool Material Ss , Smooth File With Handle - Make J K Size 10Inch Width 25 Mm Thickness 5Point8 Mm , R22 Charging Line - Make Value Material Brass 3Pc Charging Hose Suitable For R22 Gas Charging , T Handle Only 1By4inch - Handle Length 12Inch Material Ss , Multitec Screw Driver - Ph1 And S5 Ph0 And S3 In Reversible Configuration Chrome Plated Finish , T Handle 8Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber Size 8Inch , T Handle 11Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber Size 11Inch , T Handle 13Inch - Type T Socket Spanner Length 300 Mm Socket Type Hexagon Material Steel Grip Rubber Size 13Inch , Tube Cutter - Make Value Model Vtc-42 Tube Diameter 1By4inch 1 5By8inch 6 To42 Mm , Flare Nut 3By4inch - Material Brass Size 3By4inch , Square Type Condenser Fan Motor - Power 230 V Watts 36W Rpm 1500 Rpm With Stand And Blade , Tong Tester With Probes And Leather Cover - Make Fluke Model 302 Type Digital Ac Clamp Meter Jaw Opening Size 30 Mm Voltage Range Dc 0To600v Current Range Ac 0To400 A Voltage Range Ac 0To600 V Power 2 Aa Batteries 1Point5v Resistance Range 4000 Ohm Warranty 1 Year , Screw Driver Long - Make Taparia Model 931 Type Long Handle Tip Type Phillips Usage Household Product Type Screwdriver , Hammer With Wooden Handle - Make Taparia Made From High Grade Chrome Vanadium Steel Is 841 1983 Weight 500 G Type Ball Pein , Cutting Plier - Maketaparia Model 1621To8or1621to8n Combination Pliers , Tube Cutter Small - Cutter Size 1By8inch To 5By8inch Material Ss , Hexa Frame With Blade - Make Stanly , Evaporator Fan Motor For Lg Refrigerator - Make Lg Electronics Model Rda082e03 Rohs Pno Eau41681402 Ac230v Or 50 Hz 0 Point 20 By 1300T Refrigerator Model No Gl 365Yvqg5 Dsuzebn , Condenser Copper Coil Make Llyod - Copper Condenser Coil For The Llyod 1Point5 Ton Ac Size 20X30 Inch , Filter - Material Copper Type 2 Way , Single Pressure Gauge High Side500psi - Make Wikai Pressure Range 0To800 Psig Material Brass , Gauge Value - Make Value Model Vmg1slr32 Pressure 0To350 Psig Material Brass , Danfos 20 Relay Olp Set - Connector Type Through Hole Contact Type Normally Open Mounting Type Din Rail Mount Operation Mode Automatic , Try Square Set - Size 6Coma8coma10 Inch Material Carbon Steel Blade 90 Degree Heavy Duty Right Angle Ruler , Valve Core Removal Tool - Item Valve Core Remover Installer Material Copper Service Ports 1By4 Inch And 5By16inch Sae Female Bypass Ports 1By4inch Sae Male , Digital Vernier Callipers With Batteries - Material Stainless Steel Measurement Accuracy Plus Or Minus 1Percent , Siron Soldering Iron Set - Make Siron Model Dss60 Voltage 24V Power 60W Temperature Range 150 To 480 Degree Centigrade , Soldering Wire - Package Spool Type Wire Solder Wire Gauge 24 And 25 Awg Process Leaded Weight 500G , Compressor Cable Kit - Cable Feature Heat Resistance Features Both Side Clips Each Wire 2Point 5 Sq Mm Copper Cable , Handset Valve 1By4inch - One End 1By4inch Sae Female Flare The Other End 1By2 Acme Male , Cuppler - Size 1By4inch And 3By16inch Material Ss , 24 Socket Wrench Set Ratchet - Make Stanley Piece 1By2 Inch Drive Sliding Tee 1 Piece 1By2 Inch Drive Universal Joint 18 Pieces 1By2 Inch Drive 6 Point Sockets 10 Mm 11 Mm 12 Mm 13 Mm 14 Mm 15 Mm 16 Mm 17 Mm 18 Mm 19 Mm 20 Mm 21 Mm 22 Mm 23 Mm 24 Mm 27 Mm 30 Mm 32 Mm Box Included 1 Piece 1By2 Inch P9 Ratchet 2 Pieces 1By2 Inch Drive Extensions 130 Mm And 250 Mm 1 Piece 12 Inch Drive Spark Plug Socket 21 Mm , Pin Valve - Valve Type Pin Valve Exterior Finish Copper Outlet Connection Flange Material Copper 1 Packet 10 Nos , Charging Line Handle - Air Conditioner Refrigerant Angled Ball Valve 1By4inch Sae For R410a R134a R12 R22 Ac Hvac With R410a Adapter R134a Refrigerant Adapter Valve Core Thimble Remover For Mini Split System Material Brass Inlet Connection Size 0Point25 Inches Inlet Connection Type Npt Outlet Connection Type Sae Number Of Ports 3 Outlet Connection Size 0Point25 Inches Valve Type Ball Valve , Capacitor 50 Mfd - Capacity 50 Mfd Material Non Pcb Shape Round Mounting Type Internal , 3 Way 30 Amps Connector - Current Ratings 30 Amps Connector Type Screw Material Bakelite High Current Capacity , Ss Tank Nipple 1By2inch - Material Brass Thread Size 15 Mm Item Dimension Lxwxh 15 X10 X 5 Cm , Pvc Connection Pipe 1 By 2 Inch - 24 Long Brasstail Nut Connection Pipe With White Pvc 15Mm 1By2 Inch Hosepipe 60Cm , Ro Water Purifier T Type Tap - Colour Blue For The Ro Water And Material In Plastick , Ro Water Purifier Tap Tank Kent Type - Color Blue Material Plastick , Charging Line Rubber - High Quality Grade Rubber 1 Packet Equalto 50 Nos , Pipe Wrench 16Inch - Make Taparia Model 1273To12 , Bearings - 6201Z , Oil Seal - 25 47 7 A 1 Oil Seal Rajson Enterprises , Ss Breazing Roads - World Class Welding Electrodes Super Stainless Steel 308L Size 3Point15 X 350 Mm , Bluestar Indoor Blower For 1Point5 Ton Sac - Length 25Point3 Inch , Line Tester - Make Taparia Model 813 , Screwdriver Small - Make Multitec Model R6100i Type Insulated Shank Size Hexagon 6 Mm Length Of Bit 150Mm , Screwdriver Large - Make Multitec Model R6250i Type Insulated Shank Size Hexagon 6 Mm Length Of Bit 300Mm , Handle T - Make Taparia Model Takm9 , Jet Pump Handle Small - Hoselength 8M And Waterflow Rateof 8 Lperh Portable Maxium Pressure 300Bar , Araldite 500Gms - Weight For 180G The Each , Double Ended Ring Spanner Set - Make For The Taparia Size 6Mm To 32 Mm Type Ring Type , Single Guage Low Pressure For Vaccume - Make Value Model Vmg 1 S L Pressure 0To350 Psig Material Brass Suitable For R22 Refrigerant , T Type Handle Spanner Set - This Set Includes Seven Metric Sizes 8 10 12 13 14 17 And 19 Mm T Handles , Continuity Tester Compressor Check - Power Source Battery Style Digital Sound Yes Beep , Servicing Covers - Material Polyvinyl Chloride Color Blue Or Black Water Resistant Yes , Compressor For 345 Liters Refrigerator - Make Samsung Or Equivalent Model Number Mk172k S1u Refrigerant R134a Phase Single Type Rotary Warranty 1 Year , Electrical Relay - Relay With 5 Mfd Capacitor , Compressor For Minus20 Deep Freezer 320 Liters - Make Voltas Or Equivalent Model Number F60nl Refrigerant R290 Phase Single Warranty 1 Year , Compressor For 165 Liters Bpl Make Refrigerator - Makebpl Or Equivalent Model Number Sl19j-5 Refrigerant R12r134a Phase Single Warranty 1 Year , Compressor For Minus20 Deep Freezer 350 Liters - Make Danfoss Or Equi Model Nl9f And Refrigerant R134a Phasesingle And Warranty 1 Year , Filter Drier Pencil Type - Material Copper Type 2 Way For 134A Refrigerant For Minus20 Deep Freezer , Compressor For -20 Deep Freezer 500 Liters - Make Danfos Or Equivalent Model Numbersc12g Refrigerant R134a Phase Single Warranty 1 Year , Compressor For 1Point5 Tr Split Ac Rotary Type - Make Sci Or Equivalent Model Number- Rh313vamt Refrigerant R22 Phase Single Type Rotary Warranty 1 Year , Side Dummy Nuts 5By8inch - Material Brass Suitable For Outdoor Unit Service Valve Color Yellow Brass Size 5By8inch , Side Dummy Nuts 1By2inch - Material Brass Suitable For Outdoor Unit Service Valve Color Yellow Brass Size 1By2inch , Side Dummy Nuts 1By4inch - Material Brass Suitable For Outdoor Unit Service Valve Color Yellow Brass Size 1By4inch , Side Dummy Nuts 3By8inch - Material Brass Suitable For Outdoor Unit Service Valve Color Yellow Brass Size 3By8inch , Dummy Nuts 1By4inch - Hexagonal Brass Forged 1By4inch Flare Dead Nut , Ductable Split Ac Indoor Blower - Size 226X155 Suitable For 5Point5 Tr Duct Able Ac , Rubber Bushes - Type Star , Minus20 Deep Freezer Compressor - Make Embraco Or Equivalent Model Nek2150gk Warranty 1 Year , Drier Cum Filter - Make Danfoss Model 023Z5004 Size 1By4inch Brazing Type , Refrigerant R 600A - Make Godrej Of Skf Specific Name R600a Gas Type Hydrocarbon Packaging Size 200G , Hand Shut Valve For R600a Portable Cylinder - Material Brass R600a Gas Can Tap Valve With Handle Uses For Portable Gas Cylinder , Water Pipe Pvc - Flexible Water Pipe Pvc Durable Flexible Ant Kink , Acetylene Cylinder Regulator - P1 Equalto 30 Bar P2 Equalto 4 Bar Q1 Equalto 1Point9 M Per H Two Stage Gas Regulator Pressure , Oxygen Cylinder Regulator - P1 Equalto 100 Bar P2 Equalto12 Bar Q1 Equalto 30 M Per H Two Stage Gas Regulator Pressure , Hose Pipe For Acetylene - Color Red Material Rubber Brass Iso Standards , Hose Pipe For Oxygen - Color Red Material Rubber Brass Iso Standards , Torch For Oxygen Acetylene Cylinder - Uses Brazing Of R And Abyc Equipments With Iso Standards , Clamps For Hose Pipes - Size 1By2 Inchs Material Brass Uses For Hose Pipe Clamping , Hand Hacksaw Bladed - 14Inchx1inch 0 Point 050 , Axial Fan Motor For Hitachi 16Point5 Ton Ac - Make Hicool Model 4D 630S Size 25Inch 630Mm Voltage 415 Vac Power 815 Watt Current 1Point6 Amps Speed 1320 Rpm Air Direction Suction Warranty 1 Year , Compressor For Ice Machine 120 Kg Per Hr Production - Make Cubigel Or Equivalent Model No Gp14tb Refrigerant R134a Power 3By8 Hp , Filter Cum Drier - Type Brazing Size 1 By 4Inch , Compressor For Bluestar Split Ac 1Point5 Ton - Make Mistubishi Ics Or Equivalent Model Rh313vadt Refrigerant R22 Capacity 1Point5 Ton , Capacitor 45 Mfd - Capacity 45 Mfd Material Non Pcb Shape Round Mounting Type Internal , Capillary Tube Gauge - Make Refco For Measuring Capillary Inside Diameters , Soldering Liquid Flux - Uses For Stainless Steel & Multi Metals Soldering Packaging Size 100Gm , Blower For Lloyd Make Split Ac 1Point5 Ton - Size 34 1By4inch Or 87 1By2inch Cm Suitable For 1Point5 Ton Lloyd Split Abyc , Pvc Pipe 3By4inch - Size 3By4inch Material Pvc Conduit Color Grey , Pvc Bends 3By4inch - Size 3By4inch Material Pvc Conduit Color Grey , Pvc Pipe 1Inch - Size 1 Inch Material Pvc Conduit Color Grey , Pvc Bend 1Inch - Size 1Inch Material Pvc Conduit Color Grey , Clamps 3By4inch - Material Upvc Size 3Byinch 1 Packet 100 Nos , Clamps 1Inch - Material Upvc Size 3By4inch 1 Packet Equalto 100 Nos , Pvc T Joint 3By4inch - Size 3By4inch Material Pvc Conduit Color Grey , Pvc Solvent - Hp 901 Pvc 50 Ml Packaging Size 50 Ml , Cutting Machine Blade - 105 Mm 105X1x16 , Vc T Joint 1Inch - Psize 1 Inch Material Pvc Conduit Color Grey Total Quantity : 655
Contract Date: Ref. Documents Contract Value : 10.10 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
32.
Housing Urban and Rular Development #11223252 Technical Bid
Tender for Supply Of 1 Loop Analogue Addressable Fire Alarm Control Panel Expandable Up To 4 Loop, Loop Current 500Ma Maximum Per Loop, Dual Flash Based Microprocessor, Supports To Connect 240 Addressable Devices One Each Loop Via Fully Digital Communication Protocol, Equipped With A White Backlit Display (240X64 Pixel Resolution) Graphical Lcd Display With At Least 6 Lines Of Information, 200 Fire Zones (Soft Zones), Fully Programmable Via Alphanumeric Keypad Or Configuration Software, Dedicated Usb And Rs-232 Serial Port For Direct Or Pc Connection. 5500 Events Storage, Loop Current 500 Ma, Panel Shall Be Equipped With In-Built Millimeter For Live Monitoring Of Loop Current, Earth Voltage, Loop Voltage Etc., Installers Logo Application, Can Be Networked To Compatible Addressable Panels And Repeater Panels By Adding A Network Card, Features Battery Charger Status And Temperature, Supports Programmable Cause / Effect On Outputs, Panel Housing Meets Ip30 Ingress Protection Classification. , Supply Of Intelligent Analogue Optical Smoke Detector With Advanced Optical Chamber And Smoke Inlet Design To Provide Resistance To Entry Of Dust To Provide Immunity To False Alarms, Programmable Multiple Smoke Sensitivity Level Setting, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bi-Color Leds With 360O View Of Status, Auto-Addressable/Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-7 & En 54-17 Standard. , Supply Of Intelligent Analogue Class-P Heat Detector With Two Thermal Sensitivity Level, The Two Level Corresponds To Rate-Of-Rise (Ror) A1r Class (Most Sensitive) And Class Bs (Least Sensitive), Thermal Alarm Threshold For Ror A1r Class 58Oc And Bs Class 78Oc, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5 & En 54-17 Standard. , Supply Of Standard Detector Base For Mounting The Compatible Addressable Detectors. , Supply Of Intelligent Sounder Interface Module Allows Connecting Conventional Sounder Or Sounder Beacon To Addressable Loop, With In-Built Short Circuit Isolator, Allows For Two Stage Alarm Capability, Addressed Through Auto And Manual Options. Approved By Lpcb For En 54-17 & En 54-18 Standard. , Supply Of Conventional Wall Sounder With Beacon For Providing Audible And Visual Alarms In Response To The Output Signal From The Control Panel, 32 Selectable Tone And Adjustable Sound Level, Maximum Output Volume @ 1M Distance 100 Db(A), Output Tone Frequency Range 440 Hz To 2900 Hz, Visual Alarm Device Output Frequency 0.5 Hz, Approved By Lpcb For En 54-3 Standard. , Supply Of Intelligent Analogue Multi-Criteria (Combination Of Smoke And Heat) Detector With Special Algorithms To Utilize Information From Both Smoke And Heat Sensing Elements To Ensure High Level Of Immunity To False Alarms Without Compromising Genuine Alarm Sensing Performance, Programmable Multiple Smoke Sensitivity Level And 9 Modes Of Operation, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5, En 54-7, & En 54-17 Standard. , Supply Of Single Loop Driver Card Designed For Use With Compatible Analogue Addressable Panels, Provides Control And Connection/Communication To Maximum 240 Addressable Device Per Loop. , Supply Of Intelligent Analogue Manual Call Point With Resettable Operating Element, With In-Built Bidirectional Short Circuit Isolator. Bi-Color Led For Local Indication Of Device Status, Single Action Operation, Reset To Normal Condition Using Special Reset Key, Clearly Visible Alarm Flag In The Activated State. Approved By Lcpb For En 54-11 Standard. , Supply Of Mounting Accessories Like Back Box For Detectors, Devices & Cable Glands, Etc. , Supplying And Laying Of 2C X 1.5 Sq.Mm Pvc Insulated Copper Conductor Armoured Cable Encased Inside (By Providing And Laying) 1.5 Dia Pvc Insulated Conduit/Pipe Along With Fittings And Fixtures. Complete Job Includes Cost Of Material (Pvc Conduit, Cu Cable). Labour And Transportation. , providing and Fixing Of Wall Mounted Automatic Fire Extinguishers Abc Type Of Capacity 6 Kg Using Two Heat Sensing Quartzoid Bulb With Valves For Detection & Extinguishing Of Fires, Wall Mounted Automatic Fire Extinguisher Powder Based (As Per Is 4308) Automatic, Mild Steel, Hose Length 500 Millimeter, Quartzoid Bulbs Temperature Rating 68 Degree Celsius, Pressure Testing-Ped Certificate/ Ce Marking To Ped 2014/68/Eu, Annexure 3 (Module H) From Eu Notified Body. , providing and Fixing Of Stored Pressure Water Mist Based Fire Extinguishers 6 Liter Capacity. Bs En Standard Based Portable Fire Extinguishers, Conformity To Standard En 3-7 + A1: 2007 & En 3-8;2006 With Latest Amendment, Weight Of Filled Portable Fire Extinguisher (Kg) 10.438, Suitable For Class -A Fire Ratings As Per En 3-7 13A, Fire Rating For Class -F 75F,Operating Temperature (-30° C≤ N =60° C ), Warranty For The Complete Product 5 Year, Operating Temperature (+5° C To + 60° C), Service Pressure 15 Bar, Burst Pressure 112 Bar, Minimum Discharge Time (Seconds) Required As Per En Standard 12 Second, Shelf Life (Life Cycle) Of The Fire Extinguisher 10 Years, Marine Equipment Directive (Med) Approved Ce Certification From Eu Notified Body, Ce Identification Number Of The Notified Body (Must Declare),Ce 1128, Availability Of Test Report From Central Govt./Nabl/Ilac Accredited Lab To Prove Conformity To Specification Test Report No 1329B, Issue: 04, Test Report Date 20.07.2018 Name Of The Lab Bre Global Ltd. , providing and Fixing Water Mist & Caf High Pressure 50 Ltrs. Trolley (As Per En 1866-1:2007-08), Working Pressure 31 Bar, Air Bottle Capacity 6 Litre 300 Bar Pressure, Approved By Peso (Petroleum And Explosive Safety Organization),Fire Extinction - Suitability With Standard Afff 6% Confirming To Is 4989 Or Ul 162 Standards Class - A Fires, Class - B Fires, Class - B Polar Solvent Fires, Live Electrical Fires - 1000 V As Per En 3-7:2004+A1:2007 Tested For 35 Kv, Certification From Nabl Accredited Lab And Any Central Govt. Lab. (Tested In Indian Condition) As Per En 1866-1:2007-08. Test Report Shall Be Enclosed Along With The Offer, The Product Should Be Ped Certified To Ped 2014/68/Eu, Annexiii (Module H), The Supplier Should Have A License From Peso For Refilling & Storage Of High Pressure Gas Cylinders.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
33.
Housing Urban and Rular Development #11223251 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical &-Hospital Division , Jammu Supply, Installation, Testing & Commissioning Of Medical Grade Online Double Pass Reverse Osmosis(Ro) Plant Of 500 Lph Capacity For Dialysis Along With Allied Works On Turnkey Basis At Sdh Jagti Mhdj/E-Nit 10 Of 2026-27 Dated: 20.04.2026 Due : 29.04.2026 Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. 0.0 Item Code / Make Quantity Units Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rates Inclusive All Taxes Excise Duty Gst Rs. P Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Without Taxes In Rs. P Total Amount With Taxes Total Amount In Words , Medical Grade Double Pass Reverse Osmosis System Of 500 Litre Per Hour Capacity For Dialysis Unit, Along With Allied Works In Sub District Hospital Jagti, Jammu On Turnkey Basis. Complete Job As Per Site Condition In All Respect (A Turnkey Job) As Per Technical Specifications/Scope Of Work Mentioned In E-Nit At Serial No. 1 , Provided And Fixing Of Civil & Structural Works-Rooftop Shed (15Ft X 12Ft) The Civil Works Will Comprise Design, Fabrication, And Execution Of A Structurally Sound Rooftop Shed Engineered To Withstand Environmental Loads And Ensure Long-Term Service Life. Job Includes Providing And Fixing Of Elevated Reinforced Cement Concrete Base Slab: Height: 6 To 8 Inches (150-200 Mm) Above Rooftop Level. Material: M25 Grade Reinforced Cement Concrete (Rcc) With Fe-500 Tmt Bars, Conforming To Is 456:2000.Slope: 1:100 Slope Towards Drainage Points For Effective Water Runoff. Drainage System: 4-Inch Diameter Pvc Pipes (Reputed Brand), Integrated With The BuildingS Rainwater Disposal Network. Boundary Walls Construction: 230 Mm Thick Brickwork (Masonry Parapet Walls) On All Four Sides, Fixed At 2 Feet (600 Mm) Height. Plaster: Interior: Cement Mortar Plaster (1:4 Ratio) With Waterproofing Additives Exterior: Cement Mortar Plaster (1:4 Ratio) With Waterproofing Additives. Tiling Interior: 100% Vitrified Tiles (Is-Compliant) With 100 Mm High Skirting. Roofing & Cladding Material: Color-Coated Corrugated Galvanized Iron (Cgi) Sheets, 0.40 Mm Thick, For Both Roofing And Wall Cladding. Support Structure: Mild Steel (Ms) Angle Posts (50X50x5 Mm), Conforming To Is 2062 Grade, Finished With Red Oxide Primer And Synthetic Enamel Paint. Fixing: Secured With Galvanized J-Hooks And Epdm Washers. Roof Slope: Cgi Sheets On The Roof Installed With A 1:100 Slope To Align With The Drainage System, Ensuring Proper Water Runoff. All Steel Members Conforming To Is 2062 Grade, Red Oxide Primer + Synthetic Enamel Paint Finish. Secured With Galvanized J-Hooks + Epdm Washers. Access Door 1.2 M (4 Feet) Wide Ms Framed Powder-Coated Door With Heavy-Duty Lock System. Interior Finishing 100% Vitrified Tiles, Reputed Make, Is-Compliant. Skirting Up To 100 Mm Height. Electrical Works • Wiring & Distribution Concealed Wiring With Frlsh Copper Cables As Per Is 694. 10 Sq.Mm Copper Cable Dedicated To Ro Plant. Job Includes Fixtures & Accessories Ceiling Fan, Exhaust Fan, Switchboards, Lighting. 16A & 6A Sockets Of Reputed Make. Double Pole Mcbs For Safety. , Supply, Installation, Testing And Commissioning Of 5Kva Online Ups With In Build Isolation Ups/Inverter System & Stabilizer (If Required) For Power Back Up Of Ro Plant At Dialysis Centre Of Sdh Jagtifor Uninterrupted Power Supply With Maximum Battery Backup Of Load To The System Along With 2-Years Warranty. Description Of Technical Specifications: • Power Backup • 5 Kva Online Ups, Reputed Make, 4-5 Hours Backup. • Directly Connected To Ro Plant. • Range 160 - 280Vac • Pwm Technology & Igbt Based • Pure Sine Wave Output With Thd 3% • Power Factor 0.8 • Large Input Operating Range, Eliminates Unnecessary Battery • D I S C H A R G E • Ups Startup Without Battery • Multi-Functional Lcd/Led Display • In-Built Galvanic Isolation • Automatic Battery Charge In Ups Off Mode • Static Bypass And Cold Start • Emi/Rfi And Noise Filter • Generator And Solar Compatible • Auto-Restart Function • Extended Backup Time Suitable Charger • Protection: Output Short Circuit, Low Voltage Of Battery, Over Or • Lack Of Input Voltage, Overload And So On • Standard: Iec/En62040-1, 62040-2, 62040-3, Complying To Ce, Bis, Rohs, • Iso:9001, Iso:14001 • Battery Rack Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
34.
Power #11209663 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 3995405; 3995405; Service Provider-Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work. 15 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work20 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 25 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 32 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 40 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 50 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 15 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 20 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 25 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 32 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 40 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 50 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 15 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 20 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 25 Mm Dia. Nominal Bore Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :15 Mm Nominal Bore Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore Providing And Fixing Unplasticised P.V.C. Connection Pipe With Ptmt Nuts, Collar And Bush Of Approved Quality And Colour. 15 Mm Nominal Bore With 45 Cm Length. Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore Supply And Fixing Of 15Mm Dia Ci/P.V.C. Bib Cock Including Replacing Of Old Bib Cock Complete. Providing & Fixing Of 110 Mm P.V.C. Pipe 6 Kg/Cm2 Specials Such As Tee, Bend, Socket, Elbow Etc. Including Cutting Excavation Of Trenches Its Back Filling After Testing The Pipe Line, Watering, Ramming Etc. Complete Including Disposal Of Surplus Earth From The Site Up To 100 Metre As Per Direction Of Engineer-In-Charge As Required For Proper Completion Of Work. Providing & Fixing 15 Mm Dia C.P. Pillar Cock Of Approved Make Including Cost Of All Materials, Labours T&P Etc. Required For Proper Completion Of Work. Providing & Fixing Suitable P.V.C. Washer In Bib/Stop/Pillar Cock, Including Cost Of Washer, Labour T&P Etc. Providing And Fixing G.I. Union 15 Mm Nominal Bore Each Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required :15 Mm Nominal Bore. Same As Above But For G.I. Tee, Socket, Elbow, Bend Etc. Upto 50Mm Dia Providing And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type) But Orissa Pattern W.C. Pan Of Size 580X440 Mm Providing And Fixing White Vitreous China Squatting Plate Urinal With Integral Rim Longitudinal Flush Pipe. Providing And Fixing White Vitreous China Wash Basin Including Making All Connections But Excluding The Cost Of Fittings :Flat Back Wash Basin Of Size 550X400Mm. Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour.Waste Coupling 38 Mm Dia Of 83 Mm Length And 77Mm Breadth, Weighing Not Less Than 60Gms. Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. Providing & Fixing :100 Mm Sand Cast Iron Grating For Gully Trap. Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 20 Mm To 40 Mm Dia Pipe Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 50 Mm To125 Mm Dia Pipe Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level .1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). Same As Above But C.C.1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) In Superstructure For Closing Cavity 5 To 7.5 Cm Wide In Cavity Wall Complete With 10 Cm / 11.4 Cm Wide Bitumen Felt Type 3 Grade 1. Brick Work With Non Modular Fly Ash Lime Bricks (Falg Bricks) Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 12 Mm Cement Plaster In Fine Sand Of Mix With 1:6 (1 Cement: 6 Fine Sand) Cement Concrete Flooring 1:2:4. With 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. Attending Of Petty Maintenance Service Like Plumbing, Welder, Mason And Carpenter Services With One No. Plumber/Welder/Mason/Carpenter With One No. Helper Per Hour. Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore.Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main.15 Mm Nominal Bore Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931.15 Mm Nominal Bore. Providing & Fixing Bottle Trap Of C.P. Brass Including Cost Of All Materials, Labour, T&P Etc. All Complete. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required .White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm. Providing And Fixing Soil, Waste And Vent Pipes Of 100 Mm Dia. Centrifugally Cast (Spun) Iron Socket & Spigot (S&S) Pipe As Per Is: 3989. Same As Item Above Above But For 75 Mm Dia. Centrifugally Cast (Spun) Iron Socketed Supply & Fixing C.P. Brass Bib Cock Heavy Quality 15 Mm Dia (400 Gms) Isi Mark Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of Work. Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete Of 100 Mm Dia. With Sand Cast Iron S&S As Per Is 3989 Same As Item Above Above But For 75 Mm Dia And .Sand Cast Iron S&S As Per Is- 3989 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Fittings Of Diameter Of 100 Mm. Same As Item Above Above But For 75 Mm Dia. Same As Item Above Above But For 50 Mm Dia. Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors .100 Mm Inlet And 100 Mm Outlet.Sand Cast Iron S&S As Per Is: 1729. Cleaning Of Septic Tank Including Disposal Of Waste Outside The Area As Per Direction Of The Engineer Incharge Including Cost Of Removing Septic Tank Cover And Replacing Cover In Its Position Including Cost Of All Labour T&P Etc. Required For Proper Completion Of Work. Same As Above Item But For Inspection Chamber. Repair & Adustment Of Aluminum Doors And Windows For Proper Functioning By Skilled Mechanic Including All Labour T&P Etc. Required For Proper Completion Work. Supply & Fixing Of Brass Polised Hydraulic Door Closure Of Standar Size And Approved Quality In Door Shutter Including Cost Of All Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg., For Doors, Including Cost Of Cutting Floors , Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge.With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty:Float Glass Panes Of Thickness 5.5 Mm Same As Item Above But 4 Mm Thich Float Glass Panes. Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Completeupto 5Mm Depth And 5 Mm Width. Providing & Fixing Fully Glazed Anodized Aluminum Fixed Glazing With Hindalco Or Equivalent Extruded Standard Sections Of Various Thickness Show In Extruded Standard Sections Of Various Thickness Shown In Drawing Joints Mitered And Jointed As Shown In Drawing Including Providing And Fixed Of 5.5 Mm Thick Glass With Neoprene Beading All Round. The Minimum Thickness Of Anodizing On All Aluminum Sections Should Be 20 Micron With A (+) 2 Microns Tolerance. The Rate Should Include The Cost Of Fixing Of All Frame To Teak Wood Frame Or With Masonry/Rb/Rcc Structure By There Of Starting From 100 Mm Above The Bottom In Vertical Member Excluding Cost Of Teak Wood Frame. But Including Cost Of All Other Materials, Labour T&P Etc. Complete Required For Proper Completion Of Work. Same As Item Above But For Openable Window Portion As Shown In Drawings, Including Providing & Fixing Aluminum Hinges Of Heavy Quality And All Other Fitting Like Concealed Tower Bolts Handles Etc. As Per Direction Of Engineer-In-Charge Required For Proper Completion Of Work. Same As Item Above But For Openable Gate/Doors Portion As Shown In Drawings Including Providing And Fixing Pivots Of Heavy Quality And All Other Fittings Like Concealed Approved Tower Bolts, Bush Plate (As Shown In Drawing) And Approved Standard Brass Body With Brass Components 6 Levers Heavy Duly Concealed Lock Etc. Required For Proper Completion Of Work. Providing & Fixing Top Cover Of Rolling Shutters Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Providing And Laying Ceramic Glazed Floor Tiles 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown Laid On 20Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigments Etc Complete. Providing Corrugated G.S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.1.00Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J. Or L Hooks, Bolts And Nuts 8 Mm Dia. G.I. Limpet And Bitumen Washers Complete. 0.80Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Non-Asbestos High Impact Polypropylene Reinforced Cement 6Mm Thick Corrugated Sheets (As Per Is: 14871) Roofing Up To Any Pitch And Fixing With Polymer Coated J, Or L Hooks, Bolts And Nuts 8Mm Dia. G.I. Plain And Bitumen Washers Or With Self Drilling Fastener And Epdm Washers Etc. Complete (Excluding The Cost Of Purlins, Rafters And Trusses), Including Cutting Sheets To Size And Shape Wherever Required. Providing Jack Hammer With Compressor Its Lead And Operator For Making Hole In Slab And Breaking R.C.C. And Exposing Existing Reinforcement And J.C.B Machine With Driver/Operator Fuel Hire Etc. Complete. Providing And Fixing 3Mm Thick Translucent White Acrylic Plastic Sheets Of Approved Quality In False Ceiling Or Window Pan Up To Any Elevation. Providing And Fixing 6 Mm. Thick Gympsum Board In False Ceiling With Beading And All Including Fixture Where Ever As Required Including Supply All Materials, Labours, T&P Etc. Required For Proper Completion Of Work. Reinforcement For R.C.C Work Including Straightening, Cutting Bending, Placing In Position And Binding All Complete (Cold Twisted Bars). Providing And Grouting With Convextra G.P.- 2 Of Standard Quality Approved By Engineer In - Charge Including Chipping Of Rcc And Including All Labors, T&P Etc. Complete. Installation & Running Of 5 Hp /7.5 Hp Elctric/Diesel Engine Motor Pump Set With Suction Of 5 Meter Depth & Delivery Pipe Up To The Distance Of 70 Meter In Near By Pit Including Cost Of All Hire Charges Of Motor Pump Set, Operator And Fuel Etc. Complete As Pr Direction Of Engineer In Charge. Cartage Of Grass/Malwa By Tractor Trally Upto A Distance Of 1 Km From Periphery Of Area Cleared, Including Cost Of All Labour, T&P Etc. Such As Loading Unloading & Cartage, Tractor Trally, Driver, Fuel Required For Proper Comlplletion Of Work. Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level Excluding Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 15 Mm To 20 Mm Dia. Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 40 Mm To 80 Mm Dia. Providing And Fixing Bright Finished Brass/Aluminium Hanging Type Floor Door Stopper With Necessary Screws Of Approved Brand , Etc. Complete. Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For All Type Of Work Upto 52 Mts Floor As Per Specification. Providing And Fixing 110X25 Mm Outer Dia. Pvc Saddle Or 110Mm Outer Dia Pvc Including Rubber Ring. Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete For Semi Regid Or Flexibel Upto 40 Mm Dia. Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood Or Teak Wood(As Per Direction Of Engineer In Charge). Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed/ Roll Form G.I. Sheet With Zinc Coating Of 120 Gms/Sqm(Both Side Inclusive), Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corner (25 Mm X 25 Mm X 0.5 Mm), Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. As Per Specification Of Dsr. Providing And Fixing 40 Mm Thickacid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement Also Includs The Cost Of 10 Mm Thick Acid Proof Base/Lining As Per Is : 4457, Complete As Per The Direction Of Engineer-In- Charge.In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile. Supply Of 100 Mm Long 15 Mm G.I. Nozzle Including Cutting Holes In Rcc Slab, Column,Floor And Beam Including Its Fixing With Cement Mortar Including All Labour, T&P And Material Etc Complete As Per Direction Of Engineer-In-Charge. Pressure Grouting Of Crackes Honey Comb In Concrete Surface Expansion Joints Or Where Ever Required With Cement Grout Of Ratio One Part Of Cement, Four Parts Of Water And 3% Water Proofing Cicco No.3 Compound (Liquids) With The Help Of Grout Pump Of Appropriate Pressure Excluding Cost Of Fixing G.I. Nozzles Complete. As Per Engineer-In- Charge . Epoxy Adhesive Providing And Fixing Aluminum U Beading Of Required Size To Pre-Laminated/ Flush Door Shutter, Including Fixing Etc. Complete As Per Direction Of Engineer-In-Charge. Kg 435.10 Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete. On Concrete Work 12 Mm Thick Marine Plywood Conforming To Is: 710 Providing And Fixing 10 Mm Thick Acid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement As Per , Complete As Per The Direction Of Engineer-In- Charge In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile Sqm 1607.70 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete Size Of Tile 600X600 Mm Sqm Providing And Fixing G.I. Union In Existing G.I. Union 50 Mm Nominal Bore Each Providing And Fixing G.I. Union In Existingg.I. Union 25 Mm Nominal Bore Each Providing And Fixing White Vitreous China Pedestal Type (European Type/ Wash Down Type) Water Closet Pan. Each 2276.95 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. Each 297.55 12.5 Mm Thick Fully Perforated Gypsum Board Tile Made From Plasterboard Having Glass Fibre Conforming To Is: 2095 Part I, Of Size 595X595 Mm, Having Perforation Of 9.7X9.7 Mm At 19.4 Mm C/C With Center Borders Of 48 Mm And The Side Borders Of 30 Mm, Backed With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.79, With 50 Mm Resin Bonded Glass Wool Backing. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: White Glazed Fire Clay Kitchen Sink Of Size 600X450X 250 Mm Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98 Mm Long, Weighing Not Less Than 75 Gms Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Of Any Colour And Shade 8.2.2.2 Area Of Slab Over Providing And Fixing Plastic Seat Cover With Lid For Pedestal Type W.C.Pan Complete : White Plastic Seat With Lid Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5° 110 Mm Bend Neat Cement Punning Fencing With Angle Iron Post Placed At Required Distance Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With Horizontal Lines And Two Diagonals Interwoven With Horizontal Wires, Of Barbed Wire Weighing 9.38 Kg Per 100 M (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples, Turn Buckles Etc. Complete. (Cost Of Posts, Struts, Earth Work And Concrete Work To Be Paid For Separately). Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. 16.18.1 With G.I. Barbed Wire Metre Providing And Fixing G.I. Union In Existingg.I. Union 15 Mm Nominal Bore Each Dismantaling By Electrical Hilti Including Cost Of Gst 18% Pr 1100069168 Rfq 6000011061
Contract Date: Ref. Documents Contract Value : 44.22 Lakh
Government Departments No of Bidders 5
Uttar Pradesh View Result →
35.
Educational and Research Institute #11209017 AOC
Bids Are invited for Boq Iteam Double Beam Uv Visible Spectrophotometer - Variable Bandwidth 1Nm 2Nm 4Nm 8 Cell Holder , Ph Meter Basic - Range 0 To 14.00 Ph Ph Resolution 0.1 Ph To0.01 Ph Accuracy 0.01Ph Calibration Points Up To 3 Points Ph Buffer Options Usa Ph 4.01 7.00 10.01 Automatic Memory Up To 25 Readingstemperature Compensation Atc , Conductivity Tds Meter - Conductivity Range 0 To 200Mscmbig Screen Large Lcd Display With White Backlight Memory Upto 100 Readings Usb Interface 0.001 Resolution 3 Points Calibration , Uv Transilluminator - Na , Double Distillation Plant - Output 4 Ltr And Hr Cooling Water Consumption Ltr Or Hr 150 Ltr Or Hr Power Rating Kw 6 Kw , Multi Tube Vortex Mixer - Operation Mode Run And Touch Operation Speed Range 500 To 3000Rpm Litude 4Mm Horizontal Swing Timing Function Led Display Maximum Load 4Kg Process Upto 50 S Les At A Time , Orbital Shaker Digital Display - Bushless Motor Speed Range 40 200Rpm Plate Size 250 Into 250 Into 50Mm Maximum Load 2Kg Timing Function Universal Tray Platform Operation Mode 20Mm , Mini Thermostatic Incubator - High Precision Controller, Precise Temperature Control, Over Temperature Alarm,Inner Chamber Surround Heating, Uniform And Stable Temperature,Compact Design, Light Weight, Small Volume Energy Saving And Power Saving, Equipped With Handle,Easy To Carry & Clean, Mirror Finishing Stainless Steel Inner Design,Unique Geometric Cavity Clean Design. , Multiposition Magnetic Stirrer - Heating And Stirring Facility Asynchronous Control Lcd Display Brushless Motor Ss304 Stainless Steel Plate Corrosion Resistance No Of Stirring Point 4 Into 500Ml Rpm 50 1200 Time Setting Function Plate Temp 120C , Water Bath - 2 Hole 4 Hole 6 Hole 8 Hole Temperature Range Rt 5C100c Time Function Ss304 Stainless Steel Tank Human Body Movement Sensor,Automatic Temperature Control Program Ultra Small Empty Dry Burning Sensor , Digital Ultrasonic Cleaner - Temperature Range Rt 7 C To 80 C Blue Led Display Normal And Soft Power Control For The Cleaning Spots Degas Function Available Time Setting Tank Ss304 , Portable Do Meter - Polarographic Dissolved Oxygen Electrode Lcd Display With White Back Light Long Battery Life 1 Or 2 Points Calibration Auto Power Off Memory Stores Or Recalls Up To 100 Data Sets Usb Communication Interface Carrying Case Easy To Carry For Field Use , Four Probe Method Apparatus - Four Probe Arrangement For Ge Crystal S Le Ge Crystal Mounted Oven Upto 300C Thermometer 0 To 300C Constant Current Power Supply Digital Accuracy 1Percent Load Regulation 0.03 For No Load To Full Load Digital 200Mv And 20Ma , Hall S Effect Apparatus - Consists Of 7 Point 5 Kg Electromagnet Power Supply For Electromagnet 0 To 100V 6A Mp Germanium Crystal Mounted And Digital Constant Current Power Supply With Two Meters 0 200Mv And 0 20Ma Halls Voltage And Crystal Current Gauss Meter Digital 0 20K Gauss With Hall Probe And Two Wooden Stands , Fume Hood - Fume Hood Fume Hood Is An Enclosure Which Is Used To Remove Fumes And Air Borne Parti Cles At The Contaminate On Source It Is A Kind Of Fume Venti Lati On System Which Prime Work Is To Remove Smoke Dust Mist And Chemical Fumes And Restrict Their Entry Into Laboratory Environment A Laboratory Fume Hood Comprises Of Metallic Sheet Enclosure Steel Or Marble Stone Work Bench Service Fixture And Electrical Points For Fume Exhaust Heavy Duty Blowers Are Fi Tt Ed And Remotely Connected To The Duct Chemical Fume Hood Fume Cupboard And Fume Closet Are Similar Names Of Fume Hood Outer Body Made Of Ms Powder Coated Or Stainless Steel 304 Grade For Suction On In Fume Hood We Provide Centrifugal Blower Assemble Made Of Direct Drive Motor Fitted With Fluorescent Light And A Gas Cock For Gas And Air Supply Power 220 230Volts Ac Supply Working Table Size 3 Inch Into 2 Inch Into 2 Inch Whole Cabinet Made Of Cold Rolled Steel Duly Powder Coated And Inner Frp , S Le Vials 30Ml - Each Pkt Containing 100 Units , S Le Vials 50Ml - 1Pkt, Respectively Each Pkt Containing 100 Units , High Temperature Controlled Furnace - High Temp Controller Furnace 1200 Degree 9 Into 4 Into 4 Microprocessor Pid Digital Temp Indicator Cum Controller Instead Of Energy Regular Pyrometer , Micro Oven - 18 Into 18 Into 18 Temp Upto 250 Deg Double Walled Inner Chamber Of Andoized Stainless Steel Digital Temp Indicator Cup Controller Pid Temp Digital , Weighing Balance - Kab5l 220G 0.1Mg Internal Calibration Lcd Display Emfc Technology Underhook Piece Counting , Micropipettes 1Ml - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 10 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 20 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 100 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 200 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration,Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Laboratory Autoclave Vertical - Vertical Double Wall 98 Ltr Load 5Kw Size 450Mm Into 600Mm Inner And Outer Ss Radial Lock Digital Temp Indicator Fitted With Vaccum Breaker As A Safety Device 220 Volt Ac Supply , Multimeter - A Multimeter Range Instrument For Measure Of Voltage Current And Resistance Moving Coil Meter Having Red Pointers Over Two Colour Scale Complete With Test Leads Probez And Internal Battery , Current Ammeter - Dc Mounted In Beautiful Bakelite Acrylic Stand With Accuracy 2.0Percent F S D With Lock Type Terminal Packed In Card Box All Common Ranges Available , High Speed Centrifuge Remi Rpm 17300 In R 24 - Stepless Speed Regulator With Zero Speed Indicator Digital Speed Indicator.Dynamic Brake 0 To 99 Minutes Digital Count Down Timer Imbalance Detector With Cutoff Safety Lid Interlock , Celestron Handheld Digital Microscope Pro - Magnification Range 20 Into To 200 Into Ring Illuminator 8 Led Adjustable Cmos Sensor In Lieu Of Eyepiece Total Quantity : 36
Contract Date: Ref. Documents Contract Value : 63.08 Lakh
Government Departments No of Bidders 10
36.
Public Administrative Department #11202909 Technical Bid
Tender for Supply And Fixing Of Sanitary Napkin Vending Machine And Incinerators For Various Schools, Colleges, Hospitals, Sulabh Complex, Public Places Etc , Supply And Fixing Of Sanitary Napkin Vending Machine And Incinerators For Various Schools, Colleges, Hospitals, Sulabh Complex, Public Places Etc Technical Specification Of Sanitary Napkin Vending Machines: 1 Machine Type :Fully Automated, Electronic Model, Programmable,Customizable, Electronic Data Retrievable 2 Mounting Method : Wall Mounting 3 No. Of Product Columns : Two Vertical Spiral 4 Product Storage Capacity : Total 50 Napkins Packed In A Pack Of 1S 5 Dimensions (Wxdxh) Mm : 750 X 175 X 450 Mm 6 Weight : 18 Kgs 7 Construction : Made Out Of 1.1 Mm Thick Crc Anti-Corrosive Powder Coated 8 Design : Aesthetically Well Designed With Sleek Cabinet 9 Electrical : 220V /50 Hz / 15 annual periodical maintenance ,All Motors And Boards Operate On Dc 10 Vending Mechanism : Vends One Products, Upon Selecting A Product And Inserting The Required Coins Fully Electronic Coin Acceptor 11 Coin Acceptance : Accepts Six Different Variants Of Coins, Accepts Multiple Coins To Reach The Desired Value, Easily Programmable For Any New Coins In Field 12 Programming Feature : Pricing - Programmable In Field 13 Stock Out : No Stock - Lock Out Provision, If User Presses The Button, And There Is No Stock Then Display Will Show No Stock And Even If Any User Puts In Money, It Will Be Refunded 14 Customizable : Mechanically Customizable For Any Product Dimension- Easily In Field 15 Sales Data Collection : Complete Sales Data Can Be Collected In Micro- Sd Card And Can Be Viewed In Ms Excel On Computer 16 Additional Built-In Features Available : Gsm Based Online Connectivity - Optional 17 Accessibility For Free Vending Utility Service : Token / Without Token Technical Specification Of Incinerators: 1 Type Of Machine Fully Automatic 2 Purpose To Burn Scientifically Used Napkin Pads 3 Type Of Fitting Wall Mountable 4 Operation Mode Electrical / Electronic 5 Width(Mm) 300 Mm 6 Depth(Mm) 250 Mm , 7 Height(Mm) 625 Mm 8 Weight(Kg) 20Kg 9 Material Of Housing Cabinet Mild Steel (Crca Steel) 10 Operating Power Source Electrical 11 Input Power Supply 220V+/-10%, 50Hz, Ac-15 annual periodical maintenance 12 Power Consumption(Watt) 1200 13 Warranty (Years) 1 Year 14 Iso 9001 For Manufacturing Premises Yes 15 Ce Certification Yes 16 Emission Conformity To Solid Waste Management Act Yes 17 Thick Of Thermal Insulation Material 25-40 Mm 18 Flexible Emission Outlet Pipe Dia Mm 50 19 Material Of Thermal Insulation High Density Ceramic Board 20 Burning Capacity /Day(No.Of Napkins) 150-200 21 Burning Capacity/Cycle(N0.Ofnapkins) 15-20 22 Burning Time Of Full Capacity Napkins/ 40 Minutes 23 Loading Type Front Loading 24 Number Of Chambers Two 25 Temperature Display Lcd 26 Temperature Of Both Chambers Yes, Displayed 27 Detachable Ash Tray Yes 28 Emission Outlet Pipe Location Top Of Machine 29 Means Of Connecting The Unit Outlet Clamped With Usage Emission Pipe 30 Type Of Door Lock Provided Latch Type 31 Auto Cut-Of- Temperature Display Yes 32 Auto Start Yes 33 Min Burning Temperature (Degree C) Below 500 Degree 34 Min Flue Gas Treatment Temp ( C) 950 Degree 35 Residue Ash Per Napkin (Gms) 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
38.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
39.
Public Administrative Department #11199744 AOC
Carrying Out Civil Work At Required Places At Water Treatment Plant Sector 23.-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Excavation for foundation in earth, soils of all types, sand ,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed forthe foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up. Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. 25.000 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. 15.000 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. 15.000 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor 106,936.20 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape 124,729.50 as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs anddrawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing Gas or Electrical welding for structural steel section, plates as per detailed drawing. For less than 10 mm thick section. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Gound Floor Removing the tar or coba and disposing of the material as directed etc. complete. Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Providing and Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete. Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1: line and level including neat finishing scaffolding curing etc. complete. Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete. Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface applying primer coat scaffolding if necessary, and etc
Contract Date: Jun 01, 2026 Contract Value : 44.85 Lakh
Local Bodies No of Bidders 7
Maharashtra View Result →
40.
Public Administrative Department #11199742 AOC
Carrying Out Civil Maintenance Work For The Phase 1,2,3,4 At Ravet Pumping Station.-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Excavation for foundation in earth, soils of all types, sand ,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed forthe foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up. Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs anddrawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing Gas or Electrical welding for structural steel section, plates as per detailed drawing. For less than 10 mm thick section. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing Second class fly ash brick masonry with conventional / I.S. type bricks cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Gound Floor Removing the tar or coba and disposing of the material as directed etc. complete. Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Providing and Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of to 15 mm thick in C.M. 1:4 rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete. Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. line and level including neat finishing scaffolding curing etc. complete. Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete. Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface applying primer coat scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. excluding the primer coat.) etc. complete. Lift 0.0 to 3.8 M Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. Providing and fixing false ceiling of 15mm thick as per drawings including powder coated G.I. wall angle of 20 mm x 20 mm x 0.60 mm size, G.I. grid runners of size 15 mm x 38 mm at 600 mm center to center both ways and suspended using G.I. 3 mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Providing and fixing factory made panelled door shutter in single leaf 35 mm thick style and rail without ventilator with CCTW panels 12 mm thick including wrought iron hold fast and stainless steel fixtures with oil painting 3 coats etc. complete. Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One RunningMetre. Inter locking section 40 x 18 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass withall required screws and nuts etc, complete. With colour Anodising with box. etc
Contract Date: Jun 01, 2026 Contract Value : 44.74 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
41.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
42.
Educational and Research Institute #11191898 Price Bid
Tender for Civil Work , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site Ne , 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.7 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , 5.22.6 Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or Moree , 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 22.5 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 50.13.1 9 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete , 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , 11.49.2 Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tiles 600X600 Mm , 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.20.1 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Light Shade Pigment Using White Cement , 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , 5.30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 9.117.1 Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm , 9.118.2 Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece , 22.23.2 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete , 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm , 13.48.3 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Od398633/2025-2026 Supplying And Fixing Steel Pressed Single Panelled Door Of Size 120*205Cm With Steel Frames Using Superior Quality Gi Sections Made Of Tata Steel , Od398630/2025-2026 Providing And Fixing Roller Blinds Curtains Using Good Quality Materials, Fitted To The Wall With Necessary Fittings. All Complete As Per Direction Of Engineer In-Charge , Od398632/2025-2026 Providing And Fixing Of Acrylic Name Board With Printed Acrylic Board .All Work As Per The Direction Of Engineer In Charge , Od398631/2025-2026 Supply And Fixing Of Name Board Of Size 3.60*0.60M Made Of Acp Panels Supported Over Gi Frame Work , Furnishing Work , Od398627/2025-2026 Providing And Fixing Staff Table Of Size 2.00X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete.. , Od398625/2025-2026 Providing And Fixing Staff Table Of Size 1.80X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete. , Od398626/2025-2026 Providing And Supplying Staff Revolving Chair , Od398629/2025-2026 Supplying High Back Executive Chair Nylon Base Multi-Function Mechanism, With Cushion And Leather Finish, Including Transporting Charges And All Other Loading And Handling Charges. , Od398628/2025-2026 Supplying Of Public / Waiting Seating: Three Seater. ( 35 Kg - Gw ) Gauge : 14 &Rdquo;, Dimension: 173Cm * 64Cm * 89Cm. Seat Dimension : 43Cm * 51Cm * 49Cm. Seat &Amp; Back: 1.5Mm Perforated Powder Coated. Beam: 2.0Mm Mild Steel Powder Coated , Od398624/2025-2026 Supply Of Godrej Steel Shelf Of Size 1.00 X 0.50 X2.10M, 16 Gauge , Made Of Good Quality Sheet Applying Suitable Paints All Complete As Per The Direction Of Engineer-In Charge , Plumbing And Sanitary Fittings , 17.3.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.7.8 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend. , 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee , 50.18.9.13.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 12 Kgf/ Cm2- External Work- Exposed On Wall Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mml Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.17.1 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.20.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63 Mm Dia Bendl , 50.18.9.20.5 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement - 63X63x63 Mm Dia Tee , 18.54.4 Providing And Fixing Ptmt Bib Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 90 Mm Long, Weighing Not Less Than 93 Gms , Electrical Works , 90.1.1.1 Supply And Laying Medium Gauge Pvc Conduit Of The Following Sizes Conforming To Is 9537/1983 Part Iii In Roof Slab, Jointing The Pipes With Pvc Solvent Cement, Tying & Fixing The Conduit Firmly With The Re-Inforcement Etc. As Required.20 Mm , 90.2.2.1 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 1.10.2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B , 90.2.2.3 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.2.4 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.5 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Call Bell Point With 6 A Bell Push At One End And 6 A, 3 Plate Ceiling Rose At Other End - Short Point , 90.2.2.6 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points , 90.2.2.7 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Points , 90.3.18.2 Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 90.5.1.3 Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650/1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.10.3.15 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )32A Dp Switch With Indicator) , 90.10.3.14 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A Sp Switch With Indicator , 90.10.3.32 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3 Pin Plug Top With Indicator , 90.10.3.33 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3Pin Shuttered Socket , 90.15.4.2 Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.3 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.1 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.3 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 6 Way, Double Door , 2.3.4 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door , 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.10.3 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Commissioning Etc. As Required. 40 Amps Amps , 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And , 1.17.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 1.17.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 1.5 Sq. Mm , 1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 2.5 Sq. Mm , 1.17.13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 2.5 Sq. Mm , 1.17.20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 4 Sq. Mm , 1.17.29 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 6 Sq. Mm , 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 annual periodical maintenance Switch , 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 annual periodical maintenance Socket Outlet , 1.26 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.56 Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5/6 A Modular Socket Outlets And 2 Nos. 5/6 A Modular Switches, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , 1.58 Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Od398610/2025-2026 Supply ,Installation Of 32 A Kit Cat Fuse Unit Made By Porcelain/ Ceramic , Od398618/2025-2026 Providing And Fixing Of Service Pipe (32 Mm) , Od398612/2025-2026 Supply And Fixing 200Mm Plastic Shade On Existing Batten/Angle/Pendant/Bracket Fittings As Required , Od398615/2025-2026 Supply And Fixing 9 W Led Bulb On Existing Lamp Holder B22 , Od398613/2025-2026 Supply And Providing Suitable Iron Hook Grouted On The Ceiling For Hooking The Ceiling Fan , Od398622/2025-2026 Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. -200 Mm, Single Phase Light Duty Exhaust Fan In Plastic Frame ( Light Duty Exhaust Fan) , Od398616/2025-2026 Fabrication, Supply And Installation Of Wall Mounting Powder Coated Open Type Gi Meter Box Of Following Size Suitable For Fixing Single Phase Energy Meter, Kit Cat Fuse, Neutral Link Etc. Hinged Door Construction, Knock Out For Cable Entry Etc. As Required , 90.6.6.2 Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm , Od398614/2025-2026 Supply Installation Testing And Commissioning Of Single Phase Dol Starters For 0.25 To 3 Hp Motor , Od398617/2025-2026 Supply Installation Testing And Commissioning Of Water Purifier Wit The Following Specifications (12 L Ro + Uv + Tds + Controller) , Od398619/2025-2026 Supply Installation Testing And Commissioning Of Iso / Bis Certified Igbt Technology Based 2.5Kv Online Ups/Inverter With Minimum 3 Years On-Site Waaranty And Having The Following Minimum Specifications. 1. Output:230V+1% 50Hz Sine Wave Single Phase. 2. Input: 170V To 270V Hz Ac 3. Rating: 2.5Kva, 4. Backup Time: Minimum 2 Hrs, On Full Load, 5. Efficiency: 90% Or Higher. 6. Battery Bank: 150Vah/Above(2Nos) Or Higher Tubular Battery With Minimum 3 Years Warranty With Suitable Battery Rack. 7. Protection: Over Load, Short Circuit, Battery Reverse Polarity, Input Voltage Below Or Above The Specified Range Over Discharge Or Charge Of Battery, Accepted Model: Hykon Or Equivalent Brand With Better Specification. , Od398620/2025-2026 Supply, Conveyance, Installation And Testing Of 80Cm(32 Inch) Hd Ready Led Tv Of The Following Sizesusing Standard Accessories Including And Providing Wall Mounting Stands. Screen Resolution 1366X768- Hd And 2 Hdmi &Amp; 1 Usb Ports, Working On 230V/240V Single Phase A/C As Required , Od398611/2025-2026 Supply And Installation Of Set Top Box , Od398623/2025-2026 Earthing With G.I. Earth Pipe 2.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal/ Coke And Salt) As Required , Od398621/2025-2026 Supply &Amp; Installation Of 1200Mm, 20W Led Tube And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire . , Network Wiring And Installation , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 1.27.1 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.53.1 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od398643/2025-2026 Providing And Fixing Of 16-Port Gigabit Unmanaged Switch.( D-Link Dgs-1016A Or Equivalent ) , Od398639/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398644/2025-2026 Supply Installation Testing And Commissioning Of Following Sizes Of Wall Mount Network Rack. 4U 350D( But Without Server, Switches Cooling Fans Etc.) , Od398636/2025-2026 Supply Installation Testing And Commissioning Of Cat6 Utp 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port Laded Patch Panel (D-Link Or Equivalent) As Required. , Od398634/2025-2026 Supply Installation Testing And Commissioning Of Wireless Ac1200, Dual-Band And Ceiling Mount Gigabit Access Point (Tp-Link Eap225 Ac1200 Wireless Mu-Mimo Gigabit Indoor/Outdoor Access Point/ Equivalent) , Od398637/2025-2026 Supply And Stackingg Of Cat-6 Patch Cord -2M , Od398640/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable-1Mtr , Od398642/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable- 0.5 Mtr , Od398641/2025-2026 Supply, Conveyance, Installation And Testing Of Cooling Fan For Incubator, Fan For Computer Server 120 * 120 * 38Mm, 4.7 Inch Black , Od398638/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398635/2025-2026 Supply Conveyance And Installation Of Poe Injector. (Tenda Te-Poe30g-At Gigabit Poe Injector Or Equivalent) N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
43.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
44.
Tourism #11175186 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Supplying And Filling In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. Moorum , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-30 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. I.Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing And Fixing Exposed Laterite Stone Of 100 Mm Thk For Dado ,Laid On Cement Mortar Paste 1:4 (1 Cement : 4 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Stone Including Rubbing Including Applying Acrylic Varnish Etc Complete. As Per Designs And The Directions Of The Engineer-In-Charge. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete. 600X 600 Mm Dark Shades , Providing And Laying Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Lakha Red , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid . Plain White Makrana Slab 25Mm Thick , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : White Makrana Marble , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete). , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 30 Cm Lx 40 Cm H X 15 Cm T , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Steel Bars & Disposal Of Unserviceable Within 50 , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. 12 Mm Cement Plaster 1 :3 ( 1 Cement : 3 Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surfaces Etc. 50 X 12 Mm , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 250 X 16X 5Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete , Providing And Applying Decorative Plastering For A Window Sorrounding, Using 1:4 Morter Mixture With Bricks Chips,Featuring A 300Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer. (The Job Involves Applying A Decorative Finish Over Underlying Structure, Incorporation Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Double Piller At The Corner (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center For Hall(Ht 2.10 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 200Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Arch Of Span Of 3Mt., Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering Ofr Cornice At Ceiling In Hall Of Ht 0.40Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Construction And Installation 6Mt Height Replica Of Shree Suptakoteswar Stumb Using Sadhahalli Grey Granite Stone With Intricate Carvings, Moulding As Per Drawing. The Structure Should Have 6Mt Ht. With 2.5 X2.5X0.70 Mt Ht At Base And Stumb Of 1.50X1.50X5.25 Mt Height At Top As Per Details Drawings And Direction By The Engineer. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A 150Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Padma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Cornice ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Adhopadma For Sajja), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Electrical Works , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 1/2 Core 70Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 70 Sq. Mm. , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(K) 12 Way (8+36), Double Door, Horizontal Type Cat B , Supplying And Fixing 40 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C -- With Cat B Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.A) 20 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.B) 25 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Requiredd) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Requireda) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredb) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(C) 6 Module (200Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredsitc Of Wall Fan,600 Mm Sweep, With All Accessories. , Supply Installation Testing And Commissioning Of 8-10 W Spot Light Cob Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supply Installation Testing And Commissioning Of W 80W Flood Light Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =600X1500(H),Lamp Base- G9, Wattage- 7X42w Max, Complete With All Accessories. , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =1200X1500(H),Lamp Base- G9, Wattage- 12X42w Max, Complete With All Accessories. , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineerincharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately). , Supply Installation Testing and Commissioning of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 400Mm. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo Separate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip65, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of Aluminium Profile For Neon Flex , Supply Installation Testing and Commissioning of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv , Supply Installation Testing and Commissioning of High Quality Dmx Decoder, Power Input : Dc 24V , Supply Installation Testing and Commissioning of Pvc Insulated Multi Core Electrical Un Armoured Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete For Both Power And Dmx. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of Ip65 I Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System Quick Lock High Impact Materials - Long-Lasting And Reliable , Supply Installation Testing and Commissioning of Ip65 I Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Female Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options. - 12 Nos Of 6/10A Sp Outgoing Mcbs. - 1No Of 32A Tpn Incoming Mcb. , Supply Installation Testing and Commissioning of Ip Driver Box Made Up Of Pvc / Upvc And Ivory Connectors For The Internal Terminations And External Outgoing Connecting Points, Fiber / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. , Supply Installation Testing and Commissioning of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. , Supply Installation Testing and Commissioning of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. , Supply Installation Testing and Commissioning of Programming Charges , Supply Installation Testing and Commissioning of Additional Accessories For Installing The Lights As Per The Final Drawing/Site Condition Consisting Of Clamps, Brackets, Angles, Conduits, Joints, Hardwares Like Fasteners, Nut & Bolts Etc., , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 100A Tpn Mcb As Incommer And 11 Nos Of Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based Programmable Digital Almac Timer As Directed By Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
45.
Power #11168099 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
46.
Civil Aviation #11142964 AOC
Tender For Supply, Installation, Testing & Commissioning Of 350 Tr Horizontal Twin Screw Type Water-Cooled Chiller: Factory-Assembled Water-Cooled Chiller Unit Consisting Of A Semi-Hermetic Twin Screw Compressor Directly Coupled To An Energy-Efficient Minimum Ie4 Motor, Vfd-Driven With Active Harmonics Filter, Suitable For 3-Phase, 50 Hz Power Supply. The Chiller Shall Be Complete With A Shell And Tube Flooded/Falling Film Evaporator And A Water-Cooled Shell And Tube Condenser. Chiller Evaporator And Condenser Shall Have Even Pass Connections To Suit The Existing Plant Room Layout. Refrigerant Used Shall Be R-513A/R-134A, Factory Charged With Refrigerant And Oil. The Unit Shall Be Mounted On A Rigid, Fabricated Steel Frame With Anti-Vibration Isolators And An Inertia Base Suitable For Indoor Installation. The Chiller Shall Have A Maximum Sound Level Of 85 Db(A) Measured At A Distance Of 1 Meter From The Unit Under All Operating Conditions. Chiller Evaporator And Condenser Shall Be Asme Certified And U-Stamped. The Chiller Shall Be Complete With Flow Switches, Temperature Sensors, Internal Refrigerant Piping, Power And Control Wiring, And 38 Mm Thick Nitrile Rubber Insulation. The Control System Shall Be Microprocessor-Based With Lcd/Touchscreen Hmi, Supporting Full Automation, Real-Time Monitoring, Diagnostics, Alarm History And Data Logging. The Chiller Shall Support Native Bacnet/Ip Communication Protocol For Seamless Integration With The Building Management System. The Unit Shall Include All Required Safety Protections Such As High And Low Pressure Cut-Outs, Anti-Freeze Protection, Oil Pressure Monitoring, Motor Current Protection, Overload Protection, Single-Phase Preventer, Phase Reversal Protection, Earth Fault Trip And Vfd Protections. Design Conditions Shall Be: Chilled Water Inlet 55°F, Chilled Water Outlet 45°F, And Condenser Water Inlet 90°F And Condenser Water Outlet 100°F. Performance Requirements Shall Be 350 Tr Capacity With A Chilled Water Flow Rate Of 840 Gpm And A Condenser Water Flow Rate Of 1050 Gpm. At Ahri 550/590 Standard Rating Conditions, The Chiller Shall Have A Cop ≥ 6.2 (≤ 0.567 Kw/Tr) And An Iplv ≥ 8.1 (≤ 0.434 Kw/Tr). The Iseer Shall Be ≥ 7.9, Meeting Bee 4 Star Rating Or Above. At The Specified Project Design Conditions, The Chiller Shall Have A Cop ≥ 5.2 (≤ 0.676 Kw/Tr) And An Nplv ≥ 5.8 (≤ 0.606 Kw/Tr). Fouling Factors Shall Be 0.0005 Ft²·°F·Hr/Btu For The Evaporator And 0.001 Ft²·°F·Hr/Btu For The Condenser. The Chiller Shall Be Ahri Certified In Accordance With Ahri Standard 550/590 (I-P). All Civil Works Related To Reinforced Cement Concrete Foundation, Vibration Isolators, Grouting And Alignment Of The Chiller Shall Be Under The Contractors Scope. All Electrical Works, Including Supply And Installation Of Cable From The Nearest Panel To The Chiller Vfd, Termination, Earthing And Necessary Adapters For Cu/Al Cables, Shall Be Under The Contractors Scope. The Installation Shall Comply With Kerala Electrical Inspectorate Rules And Applicable Statutory Regulations. , Supply Installation Testing And Commissioning Of End Suction Top Discharge Centrifugal Pump-Set For Rated Continuousduty And Efficiency, With Necessary, Y-D Starter Placed Inside The Existing Panel If Possible, Power & Control Cabling From Starter Panel To Equipment Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, Suitable Adapter Box If Required And Earthing Of Pump, Power Cable, Bronze Impeller, Common Base Frame & Necessary, Motor, Coupling, Inertial Bases (Pedestal), Andvibration Isolators, Mechanical Seal For Recirculation Of Chilled Water. The Pumpmotor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Pump Set Shall Be Complete In All Respects As Required By The Standard Specification And Shall Suit The Following Minimum Capacities: Primary Water Pump Set Of Capacity 840 Gpm At 18M Of Wg Head , Supply Installation Testing And Commissioning Of Horizontal Split Case Centrifugal Pump-Set For Rated Continuous Duty And Efficiency, Complete With Supply And Installation Of Vfd, Along With On/Off Push Button For Local Isolation As Per Ksei Regulation Earthing, Along With Required Control Cabling, Motor, Bronze Impeller, Common Base Frame, Coupling, Inertia Bases And Vibration Isolators, Earthing Of Pump, Power Cable, And Mechanical Seal For Recirculation Of Chilled Water. The Pump Motor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Motor Speed Not To Exceed 1450 Rpm/2900Rpm. Pump Set Shall Be Complete In All Respects As Per The Technical Specifications And Shall Suit The Following Capacities: Secondary Water Pump Set Of Capacity 900 Gpm At 50 M Of Wg Head Note: Existing Power Cable From Vfd To The Pump Can Be Used , Supply Installation Testing And Commissioning Of Horizontal Split Case Centrifugal Pump-Set For Rated Continuous Duty And Efficiency, With Necessary Y-D Starter Placed Inside The Existing Panel If Possible, Power & Control Cabling From Starter Panel To Equipment Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, Suitable Adapter Box If Required, Earthing Of Pump, Power Cable, And Bronze Impeller, Common Base Frame & Necessary, Motor Coupling, Inertia Bases And Vibration Isolators, Mechanical Seal For Recirculation Of Chilled Water. The Pump Motor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Pump Set Shall Be Complete In All Respects As Per The Technical Specifications And Shall Suit The Following Capacities- Condenser Water Pump Set Of Capacity 1050 Gpm At 30 M Of Wg Head , Supply Installation Testing And Commissioning Of Frp Vertical Induced Draft Counter/Cross Flow Type Single Cell Cooling Towers (Cti Certified) Complete With Frp Basin, Frp Body, Vfd Compatible Ip55 Motor Fan, Motor Shall Be Min Ie3, Tefc And Class F Insulation, Fill Media, Distribution Basin Pipe Connections, With Drift Eliminator, Ladder, Supply And Installation Of Y-D Starter In The Existing Panel, Suitably Rated Cabling From Starter Panel To Cooling Tower Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, All Nuts And Bolts Of Ss316, Plain Cement Concrete /Rcc Foundation As Required Etc. And The Equipment Shall Be Compatible Withbacnet/ Ip Complete In All Respects As Per The Technical Specifications. The Noise Level From The Cooling Tower Shall Be Less Than 68 Db(A) At A 10-Meter Distance From The Air Inlet Side Of The Cooling Tower. Delta T - 10 °F Approach Less Than- 5 °F Fan Efficiency Less Than - 0.35Kw/L/S Wet Bulb Temperature- 83 Deg F Water Flow Rate-1050 Usgpm , Supply, Installation, Testing And Commissioning Of Condenser Water Piping Of 250 Mm Dia Pipes Of Minimum 1.2Mm Thickness Frp Coated Ms C Class Heavy Duty Pipes Laid Between Cooling Tower Pumps ,Condenser Shells And Cooling Tower Complete With All Fittings And Accessories Like Bends, Tees, Reducers, Supports, Clamps, Etc, Pipes Shall Be Applied With Bituminous Primer And Painted To Colour Codes. The Item Shall Be Complete In All Respects As Per Technical Specifications. Note : The Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From A Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. , Supply, Installation, Testing And Commissioning Of 200Mm Dia Pipes, 50Mm Puf Insulation With Hdpe Jacket Of 2Mm Thickness Factory Fabricated, Of Ms C Class Heavy Duty Pipes Complete With All Fittings And Accessories Like Bends, Tees, Reducers, Expansion Joints, Rubber Support Inserts, Clamps, Insulated With 50 Mm Thick Puf Insulation Of 36 Kg/M3 Density Confirming To Standard Specification And Repairing Of Damage To Building Etc. The Item Shall Be Complete In All Respects As Per The Technical Specifications , Supply Installation Testing And Commissioning Of 250 Mm Dia Ci Wafer/Lug Type Butterfly Valves In Condenser Water Lines, Complete In All Respects As Per Technical Specifications. The Material Of Butterfly Valves Shall Be As Body- Cast Iron, Disc- Cast Bronze Or Stainless Steel, Seat-Epdm Rubber, O-Ring-Epdm. All Butterfly Valves Shall Be Designed, Manufactured, And Tested Strictly In Accordance With Is 13095:2020 - Butterfly Valves For General Purposes. , Supply Installation Testing And Commissioning Of 200 Mm Dia Ci Wafer/Lug Type Butterfly Valves In Condenser Water Lines, Complete In All Respects As Per Technical Specifications. The Material Of Butterfly Valves Shall Be As Body- Cast Iron, Disc- Cast Bronze Or Stainless Steel, Seat-Epdm Rubber, O-Ring- Epdm. All Butterfly Valves Shall Be Designed, Manufactured, And Tested Strictly In Accordance With Is 13095:2020 - Butterfly Valves For General Purposes. , Supply Installation Testing And Commissioning Of 250 Mm Epdm Rubber Flexible Connectors (Expansion Bellows) In Condenser Water Lines, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Epdm Rubber Flexible Connectors (Expansion Bellows) In Chilled Water Lines, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 250 Mm Dia Ci Dual Plate, Wafer-Type, Spring-Loaded Non-Return Valves In Condenser Water Lines. Complete In All Respects As Per The Technical Specifications. The Valve Shall Be Of Bronze Or Gun Metal, The Body Being Of Cast Iron; Flanged Ends Shall Be Provided. , Supply Installation Testing And Commissioning Of 200 Mm Dia Ci Dual Plate, Wafer-Type, Spring-Loaded Non-Return Valves In Condenser Water Lines. Complete In All Respects As Per The Technical Specifications. The Valve Shall Be Of Bronze Or Gun Metal, The Body Being Of Cast Iron; Flanged Ends Shall Be Provided. , Supply Installation Testing And Commissioning Of 250 Mm Dia Y-Strainer Cast Iron Body, And Ss 304 Strainer In Condenser Water Piping, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Dia Y-Strainer Cast Iron Body, And Ss 304 Strainer In Chilled Water Lines, Duly Insulated In The Same Manner And Same Thickness As Chilled Water Piping, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Dia Manual Double Regulating Balancing Valve (Drv), Flanged Pn16 Construction, Cast Iron Body With Epdm-Coated Sg Iron Disc. Valve Shall Include Built-In Pressure Test Cocks With Extended Lengths For Insulation. Balancing Valves In Chilled Water Lines, Duly Insulated In The Same Manner And Same Thickness As Chilled Water Piping, Complete In All Respects As Per Technical Specifications. , Supply Installation Testing And Commissioning Of Bourdon Type Pressure Gauge, 100Mm Dial, Glycerine Filled. Case Made Of Ss 304. Range: 0-10 Bar. Complete With Ss 316 U Type Siphon And A Heavy-Duty Forged Brass/Ss Service Cock , Supply Installation Testing And Commissioning Of Stem-Type Thermometers Complete In All Respects As Per Technical Specifications. , Dismantling And Buyback , Dismantling And Buyback Of 200Tr Chiller (Including Concrete Pedestals) , Dismantling And Buyback Of 100Tr Chiller (Including Concrete Pedestals) , Dismantling And Buyback Of 200Tr Cooling Towers (Including Concrete Pedestals) , Dismantling And Buyback Of 100 Tr Cooling Towers (Including Concrete Pedestals) , Dismantling And Buyback Of Primary Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Secondary Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Condenser Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Condenser Water Lines , Dismantling And Buyback Of Chilled Water Lines With Insulation , Camc For The Chiller Through Oem Only, 1St Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 2Nd Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 3Rd Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 4Th Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 5Th Year After 2-Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 1St Year After 2-Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller,2Nd Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 3Rd Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 4Th Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 5Th Year After 2-Year Dlp
Contract Date: May 22, 2026 Contract Value : 2.01 Crore
Boards / Undertakings / PSU No of Bidders 2
47.
Defence #11122150 AOC
Bids Are invited for Supertructure Small living shelter of size 5 point 22m x 6 point 12m x 4 point 75m height with 1 point 50m wide Verandah at front and rear side , Cement OPC 43 Grade packed in HDPE bag each 50 Kg , Coarse Sand free from vegetation , Coarse aggregate 20mm graded , Coarse aggregate 40mm graded , Coarse aggregate 40 to 63 mm graded , Stone for RR Masonry less than 6 , Water Proofing Compound , Mild Steel Bars of size 10 mm and above dia conforming to IS 432 , Mild Steel Bars of size 6 to 8mm dia , MS Binding Wire , Cement OPC 43 Grade packed in HDPE bag each 50 Kg , Coarse Sand free from vegetation , Coarse aggregate 20mm graded , Coarse aggregate 40mm graded , Stone for RR Masonry less than 6 , PVC Pipes 75 mm each 3 mtr long , Non Skit Ceramic tiles of size 600 mm x 600 mm for floor thickness between 9 to 10 mm thick , White cement , Peg set of six fitted with galvanised screws along the internal surface of the walls in the rooms , Curtain Arrangement Drapery and rod made of 25 mm dia and 1600 mm long pre coated MS pipe with fancy type end , Distribution box 8 way SPN comma 240 volts copper bus bar and neutral link earthing stud , MCB SPN 240 Volts 32 Amps , MCB SP 6 to 32 Amps , PVC tape 19mm wide 5m long , Cable PVC insulated electric cables heavy duty 1100 volts grade multi stranded copper conductor of size 1 point 5 Sqmm single core FRLS , Cable PVC insulated electric cables heavy duty 1100 volts grade multi stranded copper conductor of size 2 point 5 Sqmm single core , Cable PVC insulated electric cables heavy duty 1100 volts grade multi stranded copper conductor of size 4 Sqmm single core , PVC casing capping 1 inch Medium Grade Snow white , PVC casing capping of size 3 oblique 4 inch Medium Grade snow white , Switch Piano 5 Amp 230 Volts Flush type one way snow white , LED Tuble light fittings 15W 230V box type 4 feets with CRCA body Pre coated white and Prewired for LED tuble complete , Steel screw full thread with rawl plug plug of size 1 1oblique 2 inch size , PVC switch board Snow white of size 7 x 4 inch for socket and switches , PVC switch board Snow white of size 8 x1 inch for main switch , PVC L bend and T junction joint for PVC casing and caping , Switch socket combination Snow white multipurpose 2 in 1 comma 15A comma 230V , Switch socket combination Snow white 5A comma 230V , Service bracket 40mm dia GI tubing medium grade 1 point 5m long , Service cable PVC insulated aluminium conductor 1100 volt grade Heavy duty served with inner sheathing of PVC tap and overall PVC sheathed in service connection 10 Sqmm 2 core , Ceiling rose three terminal Snow white , LED Bulk head fitting high pressure die cast aluminum front cover with glass cover with specially design gasket with LED lamp 10 watts , PVC flexible wire copper conductor multi stranded 0 point 0016 oblique 76 , PVC flexible conduit pipe 15mm dia , PVC round oblique square block , Exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers and complete fittings , Fire exitingusher of 1Kg capacity of dry powder , Earthing Plate 600x600x6mm galvanised steel suitable for GI strip fittings drilled with two nos holes for 6 mm dia near one side , CI earthing pit cover of size 300x300x6mm with angle iron ISA 20x20x3mm thick MS frame , Funnel fitted with 20mm dia GI Pipe 1point 5m long , GI Wire 4mm diameter , Charcoal , Salt normal , Air terminal single pointed aluminium rod 12mm dia and 300mm long , Testing point terminal block make of Gun metal and phosphorus bronzesize 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw , Aluminium strips 25x3mm , Galvanised iron strip 32x6mm , Funnel fitted with 20mm dia GI Pipe 1 point 5m long , Earthing Plate 600x600x6mm galvanised steel suitable for GI strip fittings drilled with two nos holes for 6 mm dia near one side , CI earthing pit cover of size 300x300x6mm with angle iron ISA 20x20x3mm thick MS frame , Insulating PVC block 75x75x30 mm with insulating clamp nut and bolt , Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof , Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique Ceiling oblique Roof , Fire ball extinguisher 1 point 3 kg with suitable provision for wall mounting and capable of self activating on contact with flames , Double Sleeping Bunk DSB complete all as per Technical Specification along with foam cum coir matress , Steel Bed Side Locker of size 1000mm x 1520mm x 450mm complete all as per Technical Specification , Study Chair of size length 56 Cm comma Height 82 Cm and Width 56 Cm comma Lacquered finish with arm comma seat and back cushion , Study Table of Size 900mm x 600mm x 760mm wih 18 mm thick prelaminated particle , Looking Mirror of size 18 x 4 inch fixed with 4 MM thick ply incl fixing arrangement , Water Dispenser of 230 V 500 Watts without refrigerator with normal cold and heating capacity of 5 lts oblique hour with storage compartment and auto shut off facility , Toyotomi Automatic Kero Room Heater comma Omni 230 , Plastic dustbin of capacity 40 ltrs , Kassi with handle , Black Steel SR Shovel Spade Belcha , Plaster trowel with wooden handle , Showel Square Nose 14 Gauge blade size 310 x 245 mm , Plumb Bob Iron , Crow Bar 1 point 5 inch dia 4 feet long , Hammer 1 Kg with Wooden Handle Durmut , Hammer 0 point 5 Kg with Wooden Handle Durmut , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 inch 305mm , Sprit Level , Measuring tape 30 Mtr Steel , Water bucket steel 13 inch dia , Picks Axes with Chisel and Point Ends Kudali 14 CP nominal weight 3 point 0 Kg , Lime brush Best quality , Painting Brush 100mm , Hacksaw frame large with blade 05 Nos , Galvanised Iron Pan Mortar Tasla comma 18 Gauge 20 inch dia , Wooden Waterproof Plywood Thickness 12mm , Nails various sizes , Rammer Earth with Handle Minimum weight 5 Kg without handle , Tester for Electrician with plastic handle 150mm , Electric Drill Machine heavy duty 500 Watt electrical backup with battery and charger , Drill bits HSS 5mm comma 8mm and 10mm dia for electric drill machine , Electric tile cutting machine with interchangable blades 05 Nos , Electrical Sheet cutter machine with blade , PUF Rivet Machine , Centre punch 8mm dia best quality , Plumbing Tool Kit , Water Level pipe 30 mtr long Total Quantity : 1742
Contract Date: Ref. Documents Contract Value : 9.75 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
48.
Communications and Information Technology  #11104473 AOC
Civil And Interior Works For Setting Up Of Igr Office At 6Th Floor Stp Ii Building- 1 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete, including primer & painting. 2 Lock & key for Drawers (Supplying, fitting and fixing Godrej Multi Lock or equivallent) . 3 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing film,Natural white . 4 For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M. 5 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. 6 Dismantling aluminium/ Gypsum partitions, doors, windows,taking out glass from fixed glazing/window and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin- charge. 7 Supplying and erecting half height or full height partition I.e. upto soffit of the ceiling, beam, false ceiling, bulk head etc made of aluminium hollow tube (50 x 50 x 2) mm frame work for both vertical and horizontal members @ 600mm bothways linked horizontally and vertically,top runners bottom skirting end trims, corner posts both horizontal as per drawing and direction with all labour and materials. Allow for cutting chase to wall, floors and mending good damages. Partition which are to be terminated at false ceiling level, the end & intermediate vertical members are to be extended upto ceiling/beam and frames are to be fitted properly by means of approved metal (Brass) expansion fastener. (measurement for ply fixing area will be cosnidered for payment) 8 Rate should include necessary hardware fittings and fixtures, adhesive, roof/height adjuster etc and arrangement shall be made to both vertical and horizontal members by cutting slots for drawing of raw power, UPS power, LAN connection, telephone etc and also making provisions for fixing of power outlets. Special cover plates, pierced for fittings of switch board should be fitted on the frame work as per drawing and direction. The rates should also include to cover the end trims by 75 mm x 25 mm (approx) Indian best quality moulded teak wood bead duly polished and malamine finish as per drawing / direction of EIC wherever applicable complete with all labour and materials. 9 to be provided glass wool of 50mm thick having density of 48 Kg per cum. to be inserted into the pre - fabricated slot covered the glass wool by marking cloths treated with Naptha @ 0.07 Ltr.per Sq.m. of cloths for acoustic purpose. complete as per directions of Engineer-in-Charge. 10 for Full height partition 11 for half height partition 12 Supplying and erecting wall panelling as per drawing and conforming to the following specification. Basic Framework:- Full height Solid partition with kapur wood frame of C.S size 2 x 2 at required spacing but not exceeding than 2-0 x 2-0. The framework shall be treated with two coats of wood preservative and fire retardant material Skin Membrane:- The skin shall comprise of a covering of 6mm thick Marine grade plywood Finishing:- 1mm thick decorative teak veneer of prescribed shade on open sides. The groove between two veneer joint shall not exceed 1.0 mm as or otherwise specified by the architect. Polish of teak veneer is included in the cost. The rate for wooden cladding will include for making out outlets of appropriate size for electrical, telephone and computer terminals wherever required 13 Providing, fitting and fixing in position frameless toughened 12 mm glazed wall fixed to the lintel/AL section/glass and floor fitted with necessary SS Patch fittings including all necessary fitting fixture. 14 Supplying and erecting wall panelling as per drawing and conforming to the following specification. Basic Framework:- Full height Solid partition with kapur wood frame of C.S size 2 x 2 at required spacing but not exceeding than 2-0 x 2-0. The framework shall be treated with two coats of wood preservative and fire retardant material Skin Membrane:- The skin shall comprise of a covering of 6mm thick Marine grade plywood Finishing:- 1mm thick decorative teak veneer of prescribed shade on open sides. The groove between two veneer joint shall not exceed 1.0 mm as or otherwise specified by the architect. Polish of teak veneer is included in the cost. The rate for wooden cladding will include for making out outlets of appropriate size for electrical, telephone and computer terminals wherever required 15 Providing and fixing Decorative frosted film (Like as: Matte, colour, texture, nature, pattern, gradient approved by the client) of approved make over glass surfaces. The film thickness is 0.1mm to 0.5mm. The film made of Polyester or Vinyl. These films have frosted and translucent finishes that ensure privacy without sacrificing natural light. They are ideal for commercial interior glazing applications such as office partitions or to meet interior design. Samples: For each type of decorative film specified, two (2) samples, 300mm square. The adhesive is activated by pressure and water. It is characterized by its permanently tacky nature and its installation ease. Film Install with no gaps or overlaps and remove air bubbles, blisters, and other defects. Be careful to remove “fingers” to eliminate any contamination or excess water pockets. It is crucial to remove as much water as possible during installation. The above modular partition should be as per specification and sample approved by client. The rate shall include all design, Engineering, 3d view and shop drawing(cad & hard copy) including approval from client, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary. services all fitting fixers complete in all respect 16 Manager/Officer/Conference chair--Supplying and installation of high back chair of dimensions approx 1200mm-1350mm (h) x 700mm-720mm (d) x 650mm-720mm (w), with nylon revolving base having heavy duty 5 nos castors, abs seat and back,height adjustable arm rest, pu molded seat and back uphoistered with leatherette, with push back locking and pneumatic gas lift mechanism, the handles will be soft pu moulded complete in all respect. 17 Work station & Visitor chair-Supplying and installation of medium back chair of dimensions approx 850mm-1000mm (h) x 630mm-720mm (d) x 650mm-720mm (w), with nylon revolving base having heavy duty 5 nos castors, abs seat and back,height adjustable arm rest, pu molded seat and back uphoistered with leatherette, with push back locking and pneumatic gas lift mechanism, the handles will be soft pu moulded complete in all respect 18 Supplying & installation of Center & Tea table of high polished SS section of AISI 304-8 grade frame work with 12mm thick tinted glass top with bevelled edge of approved quality all complete as per drawing and direction with all labour and materials including nylon sides & vacum pads 19 Supply & installation high back chair with head rest for IGR chamber --- having Leather upho;strey,pneumatic seat height adjustment , adjustable arm rest , back height adjustment , synconous tilt mechanism, multi position locking , 5 nos heavy duty castor. chair dimensions approx 1200mm-1350mm (h) x 750mm-720mm (d) x 650mm-720mm (w) . 20 Supply & Installation sofa sette 400mm seat height from floor, made of 25mm dia 1.5mm thick SS pipe legs, 3nos horizontal member of 25mm dia 1.5mm thick SS pipe (all SS are 304 grade) with internal frame made of capoor wood finished with 75mm wide elastic belt, and 100mm seat and 75mm to back high density 50 grade foam respectively 21 cladded with approved quality markin and upholstery of leather foam of approved shade & quality ( Skipper/Steller/Times etc) complete as per design and drawing with all labour and materials 22 i) 2 seater (Size: 1350mm length, 760mm width,760mm back height ) 23 Supplying & installation of Center & Tea table of high polished SS section of AISI 304-8 grade frame work with 12mm thick tinted glass top with bevelled edge of approved quality all complete as per drawing and direction with all labour and materials including nylon sides & vacum pads 24 Supply fitting fixing rollar blinds as per deirection of E-I-C. 25 Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in Charge.This item is considered for making of officer/manager/PA/reception table/storage unit etc. 26 19mm 27 12mm 28 9mm 29 Supplying, fitting and fixing boiling water proof block board conforming to IS:1659-1990 conforming to IS:848-1974 of approved make and brand, fitted and fixed as per design as per direction of Engineer-in-charge. This item is considered for making furniture items like storage unit etc. 30 19mm 31 Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-in charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. This item is considered only for furniture item like table, storage unit etc. 32 1mm thk 33 French polishing to wood work including preparing surface (ordinarygloss) 34 Supply fitting fixing SS Handle 35 Supply fitting fixingAuto Hinge 36 Supply fitting fixingTelescopic Channel 37 Supply fitting fixingkey board tray 38 Supply fitting fixingWire Manager 39 Supply fitting fixing Lock 40 Supply fitting fixingMagnatic Door Lock 41 Supply & fitting fixing Black & Gold 2 colour acrlic sheet laser cutting ,Size: 9 inch x 5inch 42 Supply & fabrication 8 mm Black acrylic lazer cutting board pasting on individual 3D letter make ( Tanishq Gold palted) with govt. logo. as per your requement . size : 3ft x5 ft. 43 Supply & fitting fixing clear acrlic sheet laser cutting pasting on 2 clour plotter vinyl other plate .15”x4” 44 Supply & fitting fixing clear & Black acrlic sheet laser cutting pasting on 2 clour plotter vinyl name plate .Size: 15 inch x8 inch =120 sq.inch 45 Supply & for 8 mm clear acrylic sheet pasting on Translite film with S.S star nut. Size: 4 ft x2 ft. 46 M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) 47 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement,lock and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge 48 Supplying, fitting & fixing Stainless Steel D or H type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in Charge fitted and fixed complete including all incidental charges. 49 Supplying Godrej mortice lock chromium plated with keys 6 levers including fitting & fixing complete 50 Supply fitting & fixing Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixedcomplete 51 Supplying and laying true to line and level vitrified tiles (size Iess than 600mmX 600 mm X 9.5 mm thick)of approved brand. Including cost of taking out /dismantling existing floor finish. 52 Applying Interior grade Acrylic Primer of approved quality and brand… 53 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) 54 Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Contract Date: May 17, 2026 Contract Value : 18.12 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
49.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
50.
Public Administrative Department #11099960 AOC
To Carry Out Various Development Works Related To Electricity At Raje Ch. Shivaji Maharaj Udyan, Vadgaonsheri.-ITEM NO : 1 GRP Pole 7 mtr Height conical shape made by Computer Numerical Controlled Filament Winding Machine using thermoset Resin (with Fire retardant and UV properties) having 62-65% glass content in one-piece, Top OD-101?1, Bottom OD-194+-1 , Avg. Pole thk: 8mm +-0.5mm. Specific Gravity (Ref Spec ASTM D 792): 1.5-1.8 gm/cm^3, Water absorption(Ref Spec ASTM D 570): <0.5%, Tensile Strength(Ref Spec ASTM D 4923): 250?50 MPa, Flextural Strength(Ref Spec ASTM D 790): 250?50 MPa, Deflection max 10% (Ref Spec ASTM D 4923) @50 kg load, Paint film thk 80-100 Micron. Two coats of UV PU Paint is must .colour as per Engineer in charge instructions.GRP Base Plate Round-350 mm Thk 18mm, PCD 270?1, Slot hole 4-18(mm)+-0.05(mm) and GRP cylindrical insert part 350 mm +-1 fitted with Pole by 8 Nos SS 304 Bolts at time of Filament winding process. Internal Junction Box (1 no. 1-1.5A SP MCB & 1 no 4 Way Connector fitted on Din rail) @ height 1000mm.Cover to be provided with Neoprene Rubber. Provision for overhead service cable - 15 mm Two round holes 180 Degree apart to be provided at 700 mm from top of pole. Rubber Grommet to be provided for both holes to avoid water ingress (if required) ( SSR Item No : 5.05 ) (PMC NON-DSR ) Unique No (03052304) Rate List Year (2023-2024) ITEM NO : 2 FRP Single arm 1/1.5 MtrBracket with SS Nut Bolts. (As per Attached Specifications) ( SSR Item No : 3 ) (PMC NON-DSR ) Unique No (06042304) Rate List Year (2023-2024) ITEM NO : 3 Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). ( SSR Item No : 16.03-09 ) (PMC Electrical ) Unique No (5465) Rate List Year (2023-2024) ITEM NO : 4 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV ( SSR Item No : 1.03-14 ) (PMC Electrical ) Unique No (3549) Rate List Year (2023-2024) ITEM NO : 5 Erecting departmentally supplied LED street light/ flood light fitting above 80 to 150W . ( SSR Item No : 2.04-25 ) (PMC Electrical ) Unique No (3886) Rate List Year (2023-2024) ITEM NO : 6 Supplying, erecting & terminating armoured cable 4 core 6 sq. mm complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( SSR Item No : 7.13 ) (PMC Electrical ) Unique No (4682) Rate List Year (2023-2024) ITEM NO : 7 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. ( SSR Item No : 7.06-09 ) (PMC Electrical ) Unique No (6909) Rate List Year (2023-2024) ITEM NO : 8 For 7m / 8m Pole: - Disconnecting cable / service wore, removing of junction box and fitting with bracket safely on ground and removal of pole. ( SSR Item No : 23.04 ) (PMC Electrical ) Unique No (6781) Rate List Year (2023-2024) ITEM NO : 9 For 9m / 10m Pole: - Disconnecting cable / service wore, removing of junction box and fitting with bracket safely on ground and removal of pole. ( SSR Item No : 23.05 ) (PMC Electrical ) Unique No (6782) Rate List Year (2023-2024) ITEM NO : 10 Transporting pole from one place to other as per instructions. ( SSR Item No : 23.02 ) (PMC Electrical ) Unique No (6779) Rate List Year (2023-2024) ITEM NO : 11 Supplying and erecting blanking plate of suitable size on MCBDB. ( SSR Item No : 5.04-14 ) (PMC Electrical ) Unique No (4385) Rate List Year (2023-2024) ITEM NO : 12 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB ( SSR Item No : 5.03-01 ) (PMC Electrical ) Unique No (4346) Rate List Year (2023-2024) ITEM NO : 13 Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( SSR Item No : 2.01-05 ) (PMC Electrical ) Unique No (3818) Rate List Year (2023-2024) ITEM NO : 14 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/ FLS2. ( SSR Item No : 2.04-06 ) (PMC Electrical ) Unique No (3867) Rate List Year (2023-2024) ITEM NO : 15 Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FGODF/ FLS2. ( SSR Item No : 2.04-16 ) (PMC Electrical ) Unique No (3877) Rate List Year (2023-2024)
Contract Date: May 15, 2026 Contract Value : 7.61 Lakh
Local Bodies No of Bidders 2
Maharashtra View Result →
TenderDetail
Loading tenders