View Bid Results For Elastromeric Pipe Tenders

We found 4 Bid Results related to elastromeric pipe tenders. You can find Contractor details who won elastromeric pipe tenders along with contract details in Bid awards announcements section.

Filters
Stage
4
Tender Publishing Platform
1
3
State / UT
3
2
1
1
Contract Value
3
1
Publish Date
0
0
0
0
0
Sector
4
1
1
1
1
Ownership
4
1
1
1
1
Within keyword
Active filters:
Showing 1–1 of 4 tenders matching your filters
1.
Public Administrative Department #8451874 AOC
Tender For General-Delampady Gp-Mcf Wiring-General Electrical Work- 1 Electrification 2 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 3 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 4 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 5 90.3.21.3:Supply & installation of light fittings on C/U shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. C/U brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture 6 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 7 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 8 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 9 OD79560/2024-2025:Supply and fixing of 10 W LED bulk head fittings IP65 die cast aluminum Poly carbonate front cover directly on wall including drilling necessary holes, giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring making good the damages, colour washing etc as required.(Philips/Bajaj/Havells/Wipro 10 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. 11 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 12 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 13 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 14 1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm 15 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 16 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 17 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 18 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) 19 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 20 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 21 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 22 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 23 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 24 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 25 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket 26 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 27 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 28 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 29 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) 30 90.11.1.18:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 31 90.11.1.10:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 32 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 33 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 34 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 35 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 36 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 37 OD137010/2024-2025:Supply and providing and fixing 63A TPNdisconnector fuse switch unit in sheet steel enclosure with ISI marked HRC fuses on wall/angle iron frame including drilling holes in frame, making connections, etc. as required 38 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL 39 90.14.24.43:Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor. 40 90.14.28.6:S & F Motor starters of the following ratingsFully automatic star delta starter for 15HP motor 41 OD79572/2024-2025:Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet 42 OD79573/2024-2025:supply and providing 4.5 Kg Dry Chemical Powder Type fire Extinguisher with hose and clamps including fixing it to wall as required. 43 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 44 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 45 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 46 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 47 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 48 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 49 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 50 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 51 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 52 OD79574/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required 53 OD79575/2024-2025:Supply and providing 12x3mm brass nut and bolt etc. as required 54 OD79576/2024-2025:Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board( GS-MB-6535) and to fix KSEB LT meters, TVM with CTs/DHD and fuse cut out etc as required including fixing it on wall, making good the damages colour washing etc. as required. 650*350*250mm 55 OD79568/2024-2025:Supply and fixing 100 A , 415V , TPN SDF with HRC fuse link in SS Enclosure making connections, etc. as required. 56 OD79577/2024-2025: S & F 100 A Fuse bases with for 100 A cylindrical HRC Fuse link in the existing meter board and giving connections etc. 57 OD79578/2024-2025:Supply and fixing of Neutral link 100 A, 2 Way neutral links mounted on DMC/SMC base- 58 OD79579/2024-2025: Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main 59 OD80009/2024-2025:Charges towards preparation of documents required for availing Service connection including Plan, scheme etc. of EI and submitting the same to concerned KSEB section office including all laison charges, transportation, AF, stamp etc. (Excluding CD, OYEC, service connection charges etc.)
Contract Date: Dec 18, 2025 Contract Value : 2.72 Lakh
Government Departments No of Bidders 1
2.
Rural Development #7180566 AOC
Tender For Electrification Of Puliyilappara Public Toilet- 1 Electrification 2 90.2.2.1:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point 3 90.2.2.3:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light point without ceiling rose - Short point 4 90.2.2.4:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point 5 90.2.2.6:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. 6 90.2.2.7:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Independent plug - Short point 7 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. 8 OD148302/2024-2025:Supply and providing the following types and power rated lamps in the existing fittings as required.Normal size 5/7 W LED lamp 9 90.3.21.3:Supply & installation of light fittings on C/U shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. C/U brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture 10 OD168295/2024-2025:Supplying and fixing Recess mounted Down lights with pressure die cast aluminium heat shrink & PC diffuser in white powder coated for low glare illumination BGLO sleek surface 18W WH SQ LED,6500K preferably Bajaj product 11 OD168296/2024-2025:Supply and fixing20 W LED flood light fitting on wall/ceiling and giving connections etc as required. (Luker LFLSL20 OR equivalent make) 12 OD168294/2024-2025:Supply, Providing and fixing 7Watts Indoor Wall Bracket and giving connection etc.as required. ( LUKER LWL 111-1 or equivalent make ) 13 90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat 14 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 15 OD148303/2024-2025:Supply and providing 1200mm efficiencia DX BLDC Ceiling fan , 5star rated double ball bearing (w/o remote) preferred Havells or equivaient reputed make. 16 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 17 OD168143/2024-2025:Supply, Conveyance Testing and commissioning decorative post top lantern27W, LED light fitting in the existing poleand giving connection as required 18 OD168144/2024-2025:Supply Conveyance, Installation and commissioning of 3mt decorative pole including connector ,foudation bolt and fixing in the existing RCC foudation etc as required make : KP 6005 of K Liteor equivalent make 19 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 20 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 21 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 22 90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket 23 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 24 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 25 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket 26 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator 27 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 28 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 29 OD148304/2024-2025:Supply , installation of 200mm sweep light duty exhaust fan in plastic body with self opening lowers working on 230 V single phase AC in the existing opening, fixing necessary anchor bolts/ bolt and nuts etc. as required including giving connections with the supplied wire along with the exhaust fan. 30 OD148305/2024-2025:Supply , installation of 305 mm sweep ,1400 rpm heavy duty exhaust fan in metal frame working on 230 V single phase AC in the existing opening, fixing necessary anchor bolts/ bolt and nuts etc. as required including giving connections with the supplied wire along with the exhaust fan. 31 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm 32 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 33 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 34 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 35 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm 36 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm 37 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 38 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 39 6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 40 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 41 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 42 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 43 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 44 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 45 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 46 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 47 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 48 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door 49 OD148307/2024-2025:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 25x3mm brass nut and bolt . 50 OD148308/2024-2025:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 25x6mm brass nut and bolt . 51 90.16.2.1:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) 52 90.11.1.15:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 53 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 54 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm 55 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid 56 90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree 57 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.End cap 58 90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Joint cover 59 OD148311/2024-2025:Supply and laying bare earthing conductors of 3.15 mm copper conductor (10 SWG) laid 0.6 mtr below ground level including excavating trench of suitable size and refilling etc. as required ( in ordinary soil). 60 OD148312/2024-2025:Painting letters or figures of the sizes 2.5 cm, 4 cm, 5cm height with enamel paint as identification mark to SB, DB, Panel board etc. as required 61 OD148313/2024-2025:S&FDanger notice board of size 100x75 mm with inception both in English and Malayalam and convention skull and bone in red. 62 OD148314/2024-2025:Supply and providing 2.00 mm thick 3.3 KV synthetic elastromeric fire retardant insulating sheet. 63 OD148315/2024-2025:Supply and installation of ABC Powder Type (Stored Pressure) Fire Extinguisher 4Kg. Capacity ISI Mark IS: 15683 consisting of M.S cylindrical body, squeeze leve,r discharge valve fitted with pressure indicating gauge, 30cm long, high pressure discharge hose, nozzle etc. with MAP Powder forA,B & C class fire, fixing on wall with wallhook etc as required. 64 OD148319/2024-2025:Supply and providing M8 eye bolt hook in wall / parapet for binding support for KSEB service main. 65 OD148320/2024-2025:Supply and providing 9L capacityGI fire bucket in post office RED with primer coat of red oxide and written with white paint FIRE mounted on MS angle frame work /wall bracket filled with fine sand painted the bracket/ floor stand including making good the damagescolour washing etc. as required as per IS2546. 66 OD148322/2024-2025:Supply and providing 18 W, LED, out door bulk head fittings on wall/ceiling and giving connections with required length of 16/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire etc as required. ( LUKER eco LBKOVSL18 or equivalent make) 67 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 68 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 69 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 70 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 71 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 72 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 73 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 74 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 75 OD148327/2024-2025:Supply ,Conveyance, installationTesting and Commissioning of 4KVA voltage stabiliser ( V-Guard ) with input voltage 170 to 270V, and output voltade range 210 to 270 V,with over load protection protection,(cut- off ), time delay, indicators etc. as required 76 OD148328/2024-2025:Supply of wall mounting 1.5 TR split type InverterA/C unit fitted with hermetically sealed compressor operating on sinle phase AC supply including non CFC refrigerant copper piping 3m with insulation ,control cable upto 5meter drain piping 3meter , condenser stand ,micro processor control with cordless remote control etc, with 1 year warrenty for machine and one year 4nos free servicepreferred DAIKIN or equivalent. 77 OD148329/2024-2025:Installation Testing and commissioning Charges of the supplied A/C unit including copper tubing ,sealing , insulating ,packing and making good the damages ,colour washing etc. as required. 78 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm 79 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm 80 90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp 81 9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) 82 OD163590/2024-2025:Supply and installation of 40A, 415V, 50Hz AC 23A4 pole on load changeover switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement on existing angle iron frame work or directly to wall using necessary bolts and nuts, fixing the unit to wall making good the damages colour washing etc. including giving necessary connections as required. 83 OD163594/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32 A, 415 V 2 way neutral Link mounted on DMC/SMC base) 84 OD163595/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32 A, HRC Fuse Base with HRC Fuse link) 85 OD148331/2024-2025:Supply, Conveyance, Installing BatterySafety Steel Stand with Door having ventilation and lock Length 100cm, Width 35cm, Heigth 90cm 86 OD166015/2024-2025:Supply, Conveyance and , Installation of150AH PREMIER TUBULARBATTERY- 5 yearsguarantee . 87 OD166016/2024-2025:Supply, Conveyance, Installing and commissioning 2KVA,24 V, premier DSP Sinewave UPS -2 years guarantee. 88 OD163592/2024-2025:Supply and providingGS-MB 3750 (inside350X481X210 mm) meter box for fixing KSEB meter with hinged door and vision panel etc, fixed on wall and giving connections as required.(Sintexor equivalent make) 89 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 90 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). 91 OD170334/2024-2025:Supply and providing tor steel for reinforced cement concrete including cutting bending and tying in shape as required. 92 OD148334/2024-2025:Charge for preparing test certificate and completion certificate for KSEB connection.
Contract Date: Mar 30, 2025 Contract Value : 6.43 Lakh
Local Bodies No of Bidders 3
3.
Power #6258771 AOC
Bids Are Invited For Kishanganga Power Station Mse Title 1 Wall Mounting Combination Tap assembly 2 Title 2 PILLAR COCK MIXTURE 3 Title 3 Vitreous China Sinks / Wash Basins Flat Back and Rectangle 4 Title 4 BIB COCK 20 MM 5 Title 5 CP BIB COCK 15MM WITH FLANGE (Long Body) 6 Title 6 CP Angle Stop Valve 20 MM 7 Title 7 CP Angle Stop Valve 15 MM 8 Title 8 Brass Solid Wedge Gate Valve 20 MM 9 Title 9 Connection pipe with Nuts 15 MM (Nylon Thread Braided PVC Pipe) 450 MM Long 10 Title 10 Connection pipe with Nuts 15 MM (Nylon Thread Braided PVC Pipe) 600 MM Long 11 Title 11 Polypropylene Collapsable Waste Pipe 12 Title 12 Box Rim Type European Pattern Toilet Seat 13 Title 13 Indian Style Squatting Pan with Orissa Pattern Squating Pan (Size 580 x440 mm ) 14 Title 14 Lever Type Flushing Cistern Dual Flush System 10 LTR 15 Title 15 Grade 1 Polypropylene Plastic Seats And Covers For Water-Closets 16 Title 16 Low Pressure Float Valve for pressure below 0.175, Mpa 100 MM Size 17 Title 17 Pattern-1 Box Rim Type European Pattern Toilet Seat (European Type WC Seat with Cistern complete) 18 Title 18 Bathroom Hand Shower Cast Brass Grade 19 Title 19 Aluminium Wall Supporting Ladders, Height 14 foot 20 Title 20 20 MM Hot-Finished Seamless(HFS) Barrel Nipples Steel Pipes Fitting 21 Title 21 Tubular Type Universal Closer (suitable for both anti-clockwise and clockwise doors without any change in the parts of closer) (Hydraulic) 22 Title 22 20 MM Hand Welded Elbow Equal Steel Pipes Fitting 23 Title 23 25 MM Hot-Finished Seamless(HFS) Elbow Equal Steel Pipes Fitting 24 Title 24 20 MM Hot-Finished Seamless(HFS) Steel Sockets Steel Pipes Fitting (Hexagon Socket) 25 Title 25 20 MM Hot-Finished Seamless(HFS) Pipe Union Steel Pipes Fitting 26 Title 26 40 MM Hot-Finished Seamless(HFS) Socket Union Steel Pipes Fitting 27 Title 27 40 MM to 25 MM High Frequency Induction Welded(HFIW) Reducing Socket Steel Pipes Fitting 28 Title 28 20 MM Brass Fancy Tap (CP Sink Mixer) 29 Title 29 Urinal Bowls (Flat Back) without Flushing RimSize 1 (410 x 265 x 305) mm 30 Title 30 20 MM Brass Fancy Tap (Single Lever CP Brass Basin Mixer) 31 Title 31 25 MM Hot-Finished Seamless(HFS) Pipe Union Steel Pipes Fitting 32 Title 32 GI UNION 32 MM 33 Title 33 Plain Toughened Window Glass (1200mm x 600mm) 34 Title 34 Access Controlled Handle Door Lock Only RFID card based Access Control 35 Title 35 Pin Tumbler Padlock(PTP) Grade-III 50 MM 36 Title 36 Socket pipe for elastromeric sealing ring jointing Unplasticized PVC Pipes For Potable Water Supplies, 75 MM (3 Inch) Dia and Length 3 Meter 37 Title 37 Plain ended pipe Unplasticized PVC Pipes For Potable Water Supplies, 20 MM Dia and Length 3 Meter Length 38 Title 38 Boiling Water Resistant or BWR Grade Plywood Size- 6 X 3 Foot, 12 MM Thick 39 Title 39 Bathroom Or Toilet Mirror with Clamp Support 40 Title 40 M-SEAL Grade 1 41 Title 41 Pipe For Gardening Purpose (25 MM Dia) 3
Contract Date: Ref. Documents Contract Value : 2.94 Lakh
Boards / Undertakings / PSU No of Bidders 6
Jammu And Kashmir View Result →
4.
Defence #3712606 AOC
Tender For Addition Alteration To Khetrapal Auditorium At Ima Dehradun; 1 Designing And Installing, Commissioning & Testing Micro Processor Controlled Central Air Conditioning Twin Screw Horizontal Type Water Chilling Machine With Vfd ( Ahri / Eurovent Certified ) Having Minimum Capacity Of 250 Tr Screw Typechilling Systemfor Khetrapal Auditorieum Ima Having Size As Attached In Layout Plan, To Maintain Inside Desire Design Condition Oftemperature 24ºc ± 2ºc Through Out The Year And Humidity 55 ± 5% And Suitable Dust Filtration Up To 5 Micron 97% Efficiency Filter At Suction And Using R134aenvironment Friendly Cfc / Hcfc Free Refrigerant, With The Following Accessories :- 2 ( A ) Chiller Machine With Vfd :- Twin Screw Horizontal Type Water Chilling Machine With Vfd Having Minimumcapacity Of 125 Tr Eachcomplete With Tefc Squirrel Cage Induction Motor Suitable For 415 +10% Volts , 3 Phase, 50Hz Ac With Automatic Starter, Micro Processorbased Panel ( Compatible With Built In Resident Communication Card To Interface Chiller, Water Cooled Condenser, Economiser, Controls ( Including Pressure Differential Switch To Control Water Flow, Electronic Expansion Valve Etc. ) , Instruments, Suction Line Andchiller Insulation, Vibration Isolators, Charge Of Refrigerant And Compressor Oil And Complete With Automatic Capacity Control System, Safety Switches, Speed Increasing Gears, Forced Feed Lubrication System Etc. Each Of The Chiling Machine Having Minimum 125 Tr Capacity , Power Cosumption Maximum Ikw / Ton At Full Load: 0.65 Kw / Tr *** Chiller Described Above.The Chiller Manufacturing Is Shell And Tube Water Cooled Condenser Of M.S. Shell And Integrally Finned Copper Tubes, Min. 2 Pass Heat Exchanger Having Maximum Pressure Drop = 3 M. Andcondensor Shell And Tube Flooded Type Chiller Consisting Of Ms Shell And Copper Tubes, 2 Pass Heat Exchanger, Duly Insulated At Factory. Evaporator Shall Have Refrigerant Sight Glass Or Automatic Refrigerent Leak Detection And Alarm System, Complete As Per Specifications And As Required. The Maximum Pressure Drop Across The Heat Exchanger Shall Be = 4M. Qty-- 02 Nos. 3 The Chiller Shall Be Meeting Following Technical Parameters :- ( I ) Chilled Water Inlet Temperature- 13.5 0 C ( Ii ) Chilled Water Outlet Temperature- 6.7 0 C ( Iii ) Cooling Water Inlet Temp - 32 0 C ( Iv ) Cooling Water Inlet Temp - 37.5 0 C ( V ) Chiller Fouling Factor - 0.000048 M20c / W ( V ) Condenser Fouling Factor - 0.000048 M20c / W ( Vi ) Minimum Cop ->6.5 ( Vii ) Minimum Ipl->9.5 ( Viii ) Refrigerant- Hfc ( Ix ) Max Pressure Drop - 4M ( Max ) 4 ( B ) Chilled Water Pump : Secondary Chilled Water End Suction Back Pull Out Chilled Water Pumps Complete With Base Frame, Cast Iron Casingclose Coupled With Spdp Squirrel Cage Induction Drive Motor, Impeller Shall Be Bronzestatically And Dynamically Balanced .Shaft Shall Beas Per ManufacturerS Recommended Specification With Machanical Seal. The Pump Shall Be Suitable To Match The Delivery / Discharge And Head Required For Above Chiller Of Capacity Not Less Than To Meet The Requirement Of Water Flow Rate Not Less Than 375 Usgpm At Head Of 30 M Wg.Qty-- 02 Nos. ( C ) Chilled Water Pump : Primary Chilled Water End Suction Back Pull Out Chilled Water Pumps Complete With Base Frame, Cast Iron Casingclose Coupled With Spdp Squirrel Cage Induction Drive Motor, Impeller Shall Be Bronzestatically And Dynamically Balanced .Shaft Shall Beas Per ManufacturerS Recommended Specification With Mechanical Seal. The Pump Shall Be Suitable To Match The Delivery / Discharge And Head Required For Above Chillerof Capacity Not Less Than To Meet The Requirement Of Water Flow Rate Not Less Than 375 Usgpm At Head Of 15 M Wg.Qty-- 02 Nos. 5 ( D ) Open Expansion Water Tank Of Minimum Capacity 500 Litrefor Chilled Water Openexpansion Tank Along With 32 Mm Elastomeric Nitrile Rubber Foam Insulation With Adhesive Wrapped With Aluminum Foil Cladding All Around The Tank Suitablefor The Chilled Water System Of Above Capacity Chilling System.- Qty-- 02 Nos. ( E ) Condenser Water Circulation Pumps End Suction Back Pull Out Chilled Water Pumps Complete With Base Frame, Cast Iron Casingclose Coupled Withsquirrel Cage Induction Motor, Impeller Shall Be Bronze Statically And Dynamically Balanced .Shaft Shall Be As Per ManufacturerS Recommended Specification With Mechanical Seal.The Motor Shall Be Tefc Squirel Cage Suitable For 415 + / - 10 % Volts.The Minimum Capacity Of Pump Shall Be Suitable To Match The Delivery / Discharge And Head Not Less Than 550 Usgpm At Total Head 15 Mwc Required For Above Chiller Plant .Qty-- 02 Nos. ( F ) Cooling Tower Cti Certified Supply Of Induced Draft Counter Flow Rectangular Type Frp Cooling Tower Suitablecomplete With Direct Drive Tefc Induction Motor, Fan, Makeup, Quickfill And Drain, Float Valve, Ladder, Fill, Drift Eliminator And Bird Protector. The Tower Shalll Have Frp Basin.Anti Water Spillage Louvers Shall Be Provided At Air Intake Sections Of The Tower. Ct Suitable For 2 X125 Tr =250 Tr Ac Plant But Not Less Than 300 Tr Capacity Or Higher As Per The Design. Following Parameters As Per Designed And Approved Conditions : Water Flow Rate Not Less Than 1040 Usgpm , Condenser Water In & Out32 Deg C & 36 Deg C Respectivelywet Bulb Temp. 28.3 Deg. Qty - 01 Nos 6 ( G ) Air Handler Unit ( I ) Design, Supply, Installation, Testing, Commissioning And Validation Of Double Skin Ahu In Thermal Break Profile With Internal Coving Constructed On 40±2 Mm Thick Cfc Free Puf Injected ( Minimum Density: 40±2 Kg / Cu. M. ) Al Profile Minimum 0.6 Mm Thick With Duly Sandwitchedpanel. Every Section Shall Have Service Window ( Openable ) And Led Light For Proper Illumination. Every Door Shall Be Controlled With Emergency As Safety. ( Ii ) Mixing Chamber : Complete With Gl Extruded Gear Operated Volume Control Damper For Fresh Air And Return Air With 20 Micron Both Suitable For Manual. ( Iii ) Prefilter : 50 Mm Thick Prefilter Of Efficiency 95 % Down To 10 Micron ( Eu- 4 ) Duly Epoxy Sealed , Made Out In Al Construction Box Type . ( Iv ) Fan Section : Fan Section Complete With Arrangement Of Fixing Of Fan And Motor Drive Unit. ( V ) Motor : Motorof2 / 4Poleandtopterminal Assembly Of Suitable Capacity. Drive Set : Pulley For Fan And Motor Bothv- Belts Shall Be Used In Drive Set. Protection Mesh Shall Be Also Supplied For This Area Wherever Required. ( Vi ) Mounting Arrangement : Al Extruded Section Shall Be Provided Below Fan And Motor . Prefabricated Slidingrail Arrangement Shall Beprovidedbelowmotor Forproper Allignment. Spring Mounted Rubber Pads Shall Be Provided Below This Section To Avoid Any Vibration. Flexible Connection At Out Let Of Fan To Discharge Section Made Out With Fire Retardant Canvas Cloth. ( Vii ) Cooling Coil : 6 No Of Chw Coil Fabricated In Copper Tubes Of Thickness Min 0.45Mm With 11 - 13 Fpialfinnesin Shine Wavesdesign.Ss Drain Tray : Ss Drain Tray Duly Insulated With 10 Mm Thick Closed Cell Nitrile Rubber Insulation 7 ( Viii ) Header : Coil Header Shall Be Of Suitable Size Ms Pipe Along With Air Purging Arrangement. ( Ix ) Micro Vee Filter :Micro Vee Filter Of Efficiency 95% Down To 5 Micron Capacity Filter Frame Shall Be In Al Anodised Sheet Construction . ( X ) Supply Air Damper : Air Discharge Section Complete With Gl Extruded Volume Control Damper At The Out Let Of Ahu Suitable For Manual Operation. ( Xi ) The Ahu Should Include Suitable Variable Frequency Drive ( Vfd ) Along With Outer Box ( Powder Coated ) And Wall Or Floor Mounting Stand ( Ms Painted ) Hvac Seriesmotor - Suitable But Minimum 15 Kw. The Ahu Of Following Discharge Capacity And Design As Per Specification Mentioned In 1.7 ( I ) To ( Xi ) :- ( 1 ) Ahu 40000 Cfm @ S.P. 90 Mmwc Suitable Cooling Capacity - 02 Nos ( 2 ) Ahu 5000 Cfm @S.P 65 Mmwc Suitable Cooling Capacity-04 Nosnote For Ahu Item No. G ( 1 ) & ( 2 ) : The Item Comprises Of Fixing Of Ahu At Desired Position By Whatever Means I.E, Pcc Work , Ms Work ( Fabrication , Welding, Brazing , Soldering Etc ) Is Deemed To Be Included In This Item. Also The Contractor Will Repair And Matchup The Surface Disturbed During Fixing Of Equipments. 8 Condenser Water Valves & Accessories Supplyand Fixingbutterfly Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washer ( Pn-10 ) Of The Size 150 Mm Dia Complete All As Specified And Directred. 9 Supply And Fixing Butterfly Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washer ( Pn-10 ) Of The Size 125 Mm Dia Complete All As Specified And Directred. 10 Supply And Fixing Butterfly Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washer ( Pn-10 ) Of The Size 40 Mm Dia Complete All As Specified And Directred. 11 Supply And Fixing Balancing Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washers ( Pn-10 ) 150Mm Dia Complete All As Specified And Directred. 12 Supply And Fixing Balancing Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washers ( Pn-10 ) 125Mm Dia Complete All As Specified And Directred. 13 Supply And Fixing Balancing Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washers ( Pn-10 ) 40Mm Dia Complete All As Specified And Directred. 14 Supply And Fixing Non Return Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washer ( Pn-10 ) Of The Size 150 Mm Dia Complete All As Specified And Directred. 15 Supply And Fixing Non Return Valve Complete With Necessary Fitting Like Flanges, Gasket And Hardware Like Nut, Bolts And Washer ( Pn-10 ) Of The Size 125 Mm Dia Complete All As Specified And Directred. 16 Supply And Fixing Pot Strainers / Y Strainers In Position Of The Size ( Pn-10 ) 200 Mm Diacomplete All As Specified And Directred. 17 Supply And Fixing Pot Strainers / Y Strainers In Position Of The Size ( Pn-10 ) 150 Mm Dia Complete All As Specified And Directred. 18 Supply And Fixing Pot Strainers / Y Strainers In Position Of The Size ( Pn-10 ) 125 Mm Dia Complete All As Specified And Directred. 19 Supply And Fixing Pot Strainers / Y Strainers In Position Of The Size ( Pn-10 ) 40 Mm Dia Complete All As Specified And Directred. 20 Supply And Fixing Industrial Type Pressure Gauges Of 100 Mm Dia With Gun Metal Valves For Isolation And Necessary Fittings, For The Ease Of Maintenance And Operation Complete All As Specified And Directred. 21 Supply And Fixing Temperature Gauges Industrial Type Temperature Gauges Of 100 Mm Dia With Thermo Well And Necessary Fittings, For The Ease Of Maintenance And Operation Complete All As Specified And Directred. 22 Supply And Fixing Auto Airvent Automatic Type Of The Sizes 15 Mm Dia Complete All As Specified And Directred. 23 Supply And Fixing Of Ms Class C Pipes Confirming To Is 1239 For Pipe Of Following Size Diacomplete With All Necessary Fittings Such As Bends, Tees, Reducers, Flanges Etc. And Supports Such As Clamps, Anti-Vibration Hangers Etc. Complete As Per Specifications & Drawings. Note:All Pipings Shall Beinsulated With 25 Mm Thick Elastomeric Nitrile Rubber Foam Insulation With Adhesive All Around And Then It Should Be Wrapped With Aluminium Foil Cladding For Whole Length Complete All As Specified And Directred. 24 200 Mm Dia Ms Pipe 25 150 Mm Dia Ms Pipes 26 125 Mm Dia Ms Pipes 27 100 Mm Dia Ms Pipes 28 65 Mm Dia Ms Pipes 29 Material And Labourfor Fabrication , Welding, Soldering, Brazing , Painting One Coat Of Enamel Paint And Painting With Two Coat Of Weather Proof Paint Overms Structural Works For Supports / Caging / Casing Of Cooling Towerarea With Ms Angles , Ms Channels, Wire Mesh Net , Ms Strips As Required At Site Complete All As Specified And Directred. 30 Fresh Air / Exhaust Air Louverssupply, Installation, Testing And Commissioning Of Extruded Aluminium Louvres With Frame Bird Screeen 60 Mm X 60 Mm Pre-Filter And Microfilter Of 10 Microns With Frame, Mounting Arrangement Etc All As Specified. 31 Chw Manifoldsupply, Installation, Testing And Commissioning Of Chilledwater Manifold With Piping Of M.S. Class C Pipe ( Consider 6 Rmt Pipe Length ) Completewith Fittings Like Elbows, Tees, Reducers, Flanges Gasket, Nut-Bolts Etc, Valves ( 5No Butterfly Valve For 50Mm Dia & Above / 5No Ball Valve Below 50Mm Dia ) , Y Type Strainer 1 No Each Manifold, 3-Way Motorized Modulating Valve, 2 No. Pressure Gauges With Isolation Ball Valve, 2 No Pg Type Analog With Dial Size 100Mm Of Range 0 To 10 Kg / Cm², Temperature Gauges With 100 Mm Dial Size With Thermowell Etc As Required Of Range -10 °C To 50°C, Automatic Air Purge Valve 1 No, 20Mm Dia Drain Valve, Cold Insulated With Site Glued, Closed Cell Fire Rated ( Fm Approved ) Nitrile Rubber Insulation Of Suitable Density ( 40-60Kg / M3 ) , Class O Insulation Of 25Mm Thick, Covered With Gc Cloth.Modulatingshall Be Compatable With Actuator Operating Voltage 24V Ac & Feed Back Signal Output. O.1 Ahu 01 :100 Mm 32 Chw Manifoldsupply, Installation, Testing And Commissioning Of Chilledwater Manifold With Piping Of M.S. Class C Pipe ( Consider 6 Rmt Pipe Length ) Completewith Fittings Like Elbows, Tees, Reducers, Flanges Gasket, Nut-Bolts Etc, Valves ( 5No Butterfly Valve For 50Mm Dia & Above / 5No Ball Valve Below 50Mm Dia ) , Y Type Strainer 1 No Each Manifold, 3-Way Motorized Modulating Valve, 2 No. Pressure Gauges With Isolation Ball Valve, 2 No Pg Type Analog With Dial Size 100Mm Of Range 0 To 10 Kg / Cm², Temperature Gauges With 100 Mm Dial Size With Thermowell Etc As Required Of Range -10 °C To 50°C, Automatic Air Purge Valve 1 No, 20Mm Dia Drain Valve, Cold Insulated With Site Glued, Closed Cell Fire Rated ( Fm Approved ) Nitrile Rubber Insulation Of Suitable Density ( 40-60Kg / M3 ) , Class O Insulation Of 25Mm Thick, Covered With Gc Cloth.Modulatingshall Be Compatable With Actuator Operating Voltage 24V Ac & Feed Back Signal Output. O.1 Ahu 01 :50 Mm 33 Motorized Fire And Smoke Dampers Supply, Installation, Testing And Commissioning Of Motorized Combination Fire And Smoke Damper ( Spring Return Type ) Of Approved Make Of Atleast 120 Minute Fire Rating And All As Specified.The Fire Damper Shall Be Complete With Electronic Temperature Sensor And Electrically Operated Actuator .The Fire Dampers Shall Be Located In The Supply / Return Air Ducts, At All Fire Rated Crossovers ( Shafts / Walls Etc. ) The Control Panel Will Be Such Located That The Reset Can Be Easily Done These Combination Smoke And Fire Dampers Shall Be Interlocked With The Building Management System For Fire Detection / Hvac And Shall Trip / Close In The Event Of Fire / Smoke In The Respective Zone Withthe Bare Fire Dampers With 400 Mm Sleeve. The Fire Damper Should Include Compatible And Suitable Fusible Link, Limit Switch And Actuator. 34 Supply And Fixing Of Electrical Gisheathedtubeelectricheaters Of 3.0 Kw Completewiththyristercontrolfor Temperatureorhumidity Control; Activated Bysingle / Multi Stepthermostat / Humidistat Asrequired.The Electricheaters Enclosure Should Be Complete In All Respect With Electric Terminal Boxes ( Isolated From Air Path ) , Heaters, Insulated Access Hatches Etc, Electrical Cabling With Glass Sleeve And With Earthing, Suitable For Installation In Ahu.All The Other Accessories For Functioning Of Heater Should Be Included In The Cost. 35 Supply And Fixing Of Electrical Gisheathedtubeelectricheaters Of 5.0 Kw Completewiththyristercontrolfor Temperatureorhumidity Control; Activated Bysingle / Multi Stepthermostat / Humidistat Asrequired.The Electricheaters Enclosure Should Be Complete In All Respect With Electric Terminal Boxes ( Isolated From Air Path ) , Heaters, Insulated Access Hatches Etc, Electrical Cabling With Glass Sleeve And With Earthing, Suitable For Installation In Ahu.All The Other Accessories For Functioning Of Heater Should Be Included In The Cost. 36 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminiumconductor Of Following Sizes Alongwith With End Termination Joint / Chiller, Cooling Tower 37 6 Sq Mm 4 Core Alxlpe 38 10 Sq Mm 4 Coreal Xlpe 39 16 Sq Mm 4 Core Al Xlpe 40 25 Sq Mm 4 Core Al Xlpe 41 70 Sq Mm 3.5 Coreal Xlpe 42 240 Sq Mm 3.5 Core Al Xlpe 43 Supplyand Fixing Of Hot Dip Galvanised Cablofil ( 300 Mm Width ) Wire Mesh Cable Trays, Manufactured With A Longitudinal T- Welded Safety Edge.Trays Shall Be Constructed With 50 X 100 Mm Mesh Configuration.All Accessories Including Couplers ( Ce25 + Ce30 + Btrcc Screw-Based Combination System Or Edrn Fast Coupling ) And Mounting Accessories Are Required Of Same Finish As Per Site Requirement..The Deflection Of Cable Tray Must Be No More Than 1 / 200Th Of The Distance Between Two Supports And Tested In Accordance With The Standard Iec 61537. Wire Mesh Cable Trays Must Be Designed With An Optimum Span Of 1.5 M, Taking Into Account The Maximum Carrying Capacity Authorised By The Manufacturer. Assemblies With Specific Fire Resistant Properties Must Have An E30-E90 Certificate. Supports, Brackets Or Hangers Designed, Mechanically Tested And Supplied By The Wire Cable Tray Manufacturer To Be Used And All As Specified And Directed. 44 Dismantling Of Old Unsv Existing Central Air Conditioningplantcomprising Ahu, Cooling Towers Chillers, Condenser Pumps, Ducts , Grills And Related Items And Deposited To E / M Store Yard Of Ge Ima. 45 Supply, Installing, Commissioning And Testing Lt Main Panel Board For Ac Plant ( Indoor Type ) Cubical Type Made Out Of Crca Sheet 2Mm Thick Dust And Vermin Proof And Angle Iron Of Size 50 X 50 X 6Mm, Pedestal Frame Grouted In Pcc ( 1:2:4 ) Type B-1, 20Mm Graded Stone Aggregated Thimble And Cable Entry Boxes With Cable Glands. Panel Should Covered From All Sides With Front And Back Lockable Door And Hinges Complete With Copper Bus Bar Of Capacity 1200 Amps, Tpn, Including Internal Power & Control Wiring With Pvc Insulated Copper Wireall As Required. ( In Separate Chamber ) Including Painting With Two Coats Synthetic Enameled Paint Over A Coat Of Red Oxide Primer And Consisting Of The Following :- 46 ( A ) Incoming ( I ) Acb800 Amp, 4Pole, 415 Volts 35 Ka Microprocesser Based-01 No. ( Ii ) Digital Voltmeter 0-500 Volts - 01 No ( Iii ) Digital Ammeter0-800 Amps With Suitable Ratio Of Cts - 01 No. ( Iv ) Indicating Lamp Set Ryb, Led Type - 01 No. ( B ) Outgoing ( I ) Mccb 4 Pole 250Amps, 415 Volts , 25 Ka . With Microprocessor Release.– 02 Nos ( For Chiller ) ( Ii ) Mccb 4 Pole 400Amps, 415 Volts , 25 Ka With Microprocessor Release– 02 Nos ( Ahu Panel ) ( Iii ) Mccb 4 Pole 63 Amps, 415 Volts , 25 Ka With Microprocessor Release– 06 Nos ( Condenser Pump -2 Chiller Pump-4 ) ( Iv ) Mccb 4 Pole 100 A, 415 Volts , 25 Ka With Microprocessor Release- 01 Nos ( Cooling Tower ) ( V ) Fully Automatic Star Delta Starter, Three Phase, 415 Volts, 50 Hz Ac Supply Of Suitable Capacity Hp / Kw For Chill Water Pump With Overload Earth Fault Relay Including On / Off Indicator Lamp And Suitable Ampere Meter With Necessary Ct, Selector Swicth. - 04 Nos. ( Vi ) Fully Automatic Star Delta Starter, Three Phase, 415 Volts, 50 Hz Ac Supply Of Suitable Capacity Hp / Kw For Condensor Water Pumpwith Overload Earth Fault Relayincluding On / Off Indicator Lamp And Suitable Ampere Meter With Necessary Ct, Selector Swicth. - 02 Nos. ( Vii ) Fully Automatic Star Delta Starter, Three Phase, 415 Volts, 50 Hz Ac Supply Of Suitable Capacity Hp / Kw With Overload Earth Fault Relay For Cooling Tower Including On / Off Indicator Lamp And Suitable Ampere Meter With Necessary Ct, Selector Swicth. - 01 Nos. ( Ix ) Mccb 4 Pole 100 A, 415 Volts , 25 Ka With Microprocessor Release- 01 Nos ( Spare ) 47 Supply, Installing, Commissioning And Testing Lt Panel Board For Ahu ( Indoor Type ) Cubical Type Made Out Of Crca Sheet 2Mm Thick Dust And Vermin Proof And Angle Iron Of Size 50 X 50 X 6Mm, Pedestal Frame Grouted In Pcc ( 1:2:4 ) Type B-1, 20Mm Graded Stone Aggregated Thimble And Cable Entry Boxes With Cable Glands. Panel Should Covered From All Sides With Front And Back Lockable Door And Hinges Complete With Copper Bush Bar Of Capacity 300 Amps, Tpn, Rate Chamber, Includinginternal Power & Controle Wiring With Pvc Insulated Copper Wirepe All As Required , Including Painting With Two Coats Synthetic Enameled Paint Over A Coat Of Red Oxide Primer And Consisting Of The Following :- 48 ( A ) Incoming ( I ) Mccb 400 Amp, 4Pole, 415 Volts 35 Ka Microprocesser Based-01 No ( Ii ) Digital Voltmeter 0-500 Volts - 01 No ( Iii ) Digital Ammeter0-400 Amps With Suitable Ratio Of Cts - 01 No. ( Iv ) Indicating Lamp Set Ryb, Led Type - 01 No. ( B ) Outgoing ( I ) Mccb 4 Pole 63 Amps, 415 Volts , 25 Ka . With Microprocessor Release.– 02 Nos ( 2 Ahu Motor ) ( Ii ) Mccb 4 Pole 100 Amps, 415 Volts , 25 Ka . With Microprocessor Release.– 02 Nos ( 2 Heater Bank ) ( Iii ) Mccb 4 Pole 32 Amps, 415 Volts , 10 Ka With– 02 Nos ( 02 Small AhuS 5000 Cfm ) ( Iv ) Mccb 4 Pole 40 A, 415 Volts , 25 Ka With Microprocessor Release- 02 Nos ( Heater Of 5000 Cfm Ahu ) ( V ) Fully Automatic Star Delta Starter, Three Phase, 415 Volts, 50 Hz Ac Supply Of Suitable Capacity Hp / Kw, With Overload Earth Fault Relay For Ahu 40000 Cfm Including On / Off Indicator Lamp And Suitable Ampere Meter With Necessary Ct, Selector Swicth. - 02 Nos. ( Vi ) Fully Automatic Star Delta Starter, Three Phase, 415 Volts, 50 Hz Ac Supply Of Suitable Capacity Hp / Kw With Overload Earth Fault Relayfor Ahu 5000 Cfm Including On / Off Indicator Lamp And Suitable Ampere Meter With Necessary Ct, Selector Swicth. - 04 Nos. ( Ix ) Mccb 4 Pole 100 A, 415 Volts , 25 Ka With Microprocessor Release- 01 Nos ( Spare ) 49 Note For Item No.Lt Panels : ( I ) Interlock Wiring Of Complete Ac Plant So That It Can Trip Whenever There Is Any Fault As Per Standard Safety Norms. ( Ii ) Chw Flow Control Actuated Valve And Heater To Be Worked Based On Required Temperature And Rh Setpoint, ( Ii ) Heater Should Not Be Started Unless And Until Desired Temperature Not Achieved In Side The Room ( Iii ) Motor Should Not Start If Ahu Door Is Open ( Iv ) Call Light On And Motor Stop If Ahu Door Is Open ( V ) Heater Should Start Only If Ahu Motor Is In Running Condition ( Vi ) Ahu Motor Must Be Stopped If Ahu Door Is Open, Fire Damper Link Brocken, Incomer Power Supply Controlswitch / Mccb ( Vii ) Indicator For Ryb Power Supply, Indicator For Heater Bank On / Off, Indicator For Motor Tripping, On / Off Push Buttons With In-Built Led Lamps Be Provided. ( Viii ) Heater Bank Power Supply & Interlocking With Blower, Chw Pibcv Actuator Unit Power Supply &Interlocking Etc As Per Safety Norms And Standard Sequence.. ( Ix ) Interlocking Like - Marine Lamp, Limit Switches Etc As Required Auto / Manual Control And Status 50 Material And Labour For Earthing With Galvanised Steel Earth Plate Electrode60cmx60cmx 6Mm Thick Burried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level Connected To 4Mm Thick Gi Wire By Means Of Nuts, Bolts, Check Nuts & Washers Of Galvanized Iron Or Steel, Protected By 15Mm Bore Light Grade Galvanised Iron Pipe And Connected To Main Switch Board, Including All Necessary Excavation & Earth Work In Hard Dense Soill Including Funnel With Wire Mesh And Watering Pipe 20 Mm Bore Medium Grade Galvanised Iron Pipe With Charcoal And Common Salt In Alternate Layers Of 15 Cm Thickness All Around The Gi Plate Electrode With Concrete Pit In Pcc 1:3:6 Type C-1 With Cast Iron Frame Including Cast Iron Cover10mm Thick Hinged To Ci Frame And 6Mm Ms Rod For Handle And Necessary Testing Complete All As Shown In Electrical Plate No 3 Of Ssr Part-I All As Specified And Directed. ( Earthing For Pumps ) 51 Supply And Fix Galvanised Iron Wire 4 Mm On Porcelain Saddle On Wall / Floor / Roofs / Buried In Groundincluding Taking Down Old Unsv Strip Of Any All As Directed. 52 Material And Labour For Earthing With Galvanised Steel Earth Plate Electrode60cmx60cmx 6Mm Thick Burried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level Connected To 32 X 6 Mmthick Gi Strip By Means Of Nuts, Bolts, Check Nuts & Washers Of Galvanized Iron Or Steel, Protected By 15Mm Bore Light Grade Galvanised Iron Pipe And Connected To Main Switch Board, Including All Necessary Excavation & Earth Work In Hard Dense Soill Including Funnel With Wire Mesh And Watering Pipe 20 Mm Bore Medium Grade Galvanised Iron Pipe With Charcoal And Common Salt In Alternate Layers Of 15 Cm Thickness All Around The Gi Plate Electrode With Concrete Pit In Pcc 1:3:6 Type C-1 With Cast Iron Frame Including Cast Iron Cover10mm Thick Hinged To Ci Frame And 6Mm Ms Rod For Handle And Necessary Testing Complete All As Shown In Electrical Plate No 3 Of Ssr Part-I All As Specified And Directed. ( Earthing For Pumps ) 53 Supply And Fix Galvanised Iron Strip 32Mm X6mm On Porcelain Saddle On Wall / Floor / Roofs / Buried In Groundincluding Taking Down Old Unsv Strip Of Any All As Directed. 54 Supply, Fabrication, Installation And Testing Sheet Metal Ducts Exposed Round Or Rectangular In Accordance With Approved Shop Drawing. All Supports And Flange Joints To Be Painted. All Ducts To Be Joined With Ms Fabricated Flange, Fixing With Gi Nut Bolt And 3X25 Mm Neoprene Rubber Gasket To Be Used For Flange Joint, Duct Final Joint Fixing With Non Acidic Grad Silicone, Main Duct Leak Test By Soap Solution, Pressure Test On 150 Mm Wc, Gi Threaded Rod And Painted Ms Angle To Be Used For Duct Support, Duct Measurement Will Be At Actual Duct Surface Area, Insulation Measurement Will Be At Actual Surface Area After Insulation, All Insulation Joint Overlap By Matching Colour One Side Adhesive Pp Tap And Aluminul Claddingnote : All Duct Banding To Be Done By Machine Only, Required Fabrication Support Or Provision For Duct Hanging Or Mounting Is In Contractor Scope, Proper Silicon To Be Applied For All Joints Sealing Up To 400 Mm Duct Size 25 X 25 X 3 Mm Ms Angle To Be Used For Duct Flange Above 400 To 750 Duct Size 40 X 40 X 3 Mm Ms Angle To Be Used For Duct Flange Above 750 To 1000 Duct Size 40 X 40 X 5 Mm Ms Angel To Be Used Fir Duct Flange Above 1000 Mm Duct Size 50 X 50X 5 Mm Ms Angle To Be Used For Duct Flange Of 18 Gauge 55 Testing Of Complete Existing Airconditioning Duct ( Pressure ) Whose Surface Area Is Approx550 Sq M And Cleaning And Repairing Of Duct Wherever Required. 56 Supply And Installation Of ( Accoustic ) Duct Liner ( Insulation ) Of 19 Mm Thickness Of Elastromeric Rubber Insulation Manafactured As Per Astm E 84 Test & Which Should Also Meet Nfpa 90A Supplementary Materials For Air Distribution System Which Should Not Absorbs Less 0.2% Water By Volume ( Astm C 209 ) , Should Not Support Microbial Growth ( Astm C1071, G21, G22 ) And Should Emit Objectionable Odors ( Astm C 665 ) And Should Have Thermal Conductivity Of 0.27 ( R - 2.78 In 3.4 Thickness ) And Water Vapor Permeance Of 0.10. - Class 1 57 Fiberglass Wool Insulation Max Temperature Resistance 0-200 Degree Celsius, Moisture Rate Less Than 2%, Water Content Less Than 2%, Density 12 Kg / M3 - 48 Kg / M3, Thermal Conductivity 0.030 - 0.041 At 25 Degree Celsius. 25 Mm Thick Including Aluminium Perforated Net.
Contract Date: May 01, 2024 Contract Value : 1.92 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
TenderDetail
Loading tenders