View Bid Results For Earth Moving Machinery Tenders

We found 366 Bid Results related to earth moving machinery tenders. You can find Contractor details who won earth moving machinery tenders along with contract details in Bid awards announcements section.

Filters
Stage
320
30
16
Tender Publishing Platform
138
228
State / UT
28
131
53
50
20
17
13
8
8
7
7
7
6
4
4
4
4
4
3
3
3
3
1
1
1
1
1
1
1
Contract Value
138
88
115
24
Publish Date
2
0
0
0
0
Sector
17
128
91
61
35
9
9
6
5
5
5
4
3
1
1
1
1
1
Ownership
4
136
125
85
20
Within keyword
Active filters:
Showing 1–8 of 366 tenders matching your filters
1.
Water Resources and Irrigation #11491318 AOC
Repairs To Electro- Mechanical Items And Civil Works In Gandhinagar L.I.Scheme On Tungapadu Vagu Near Gandhinagar (V), Damaracherla(M), Nalgonda District (5Th Call).-Excavation for Structures- Mechanical Means ( Data adopted from MORTH) Earth work in excavation in all kinds of soils of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material Depth upto 3 m Excavation in ordnary rock (including HDR) without blasting including boulders above 0.3 m upto 0.60 m dia. for foundations of canal cross drainage and other appurtenant structures and placing the excavated stuff neatly in specified dump area or disposing off the same as directed etc.,complete with initial lead upto 50m and initial lift upto 3m. Providing & constructing Sand filling below foudation including cost of all materials,machinery, labour, watering, ramming etc., complete with initial lead upto 50 m and all lifts. Providing and laying insitu vibrated M-10 ( 28 days cube compressive strength not less than 10 N / sq mm ) grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates for piers and abutments including cost of all materials, labour, machinery, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.Note: If water is to be brought from other place add only lead charges @ 500 ltr / cum. (Cement content: 220 kg / cum with use of super plasticiser(0.4% by wt. of cement), CA : 0.90cum, Blending Ratio of CA--50:30:20, FA : 0.40 cum) Providing and laying insitu vibrated M-15 ( 28 days cube compressive strength not less than 15 N / sq mm ) grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates for sub-structure / super- structure works including cost of all materials,machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position,levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.(Cement content: 280 kg / cum with use of super plasticiser(0.4% by wt. of cement),CA : 0.80cum, Blending Ratio of CA--65:35, FA : 0.45 cum) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (500 mm Dia) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (400 mm Dia) Supply and fixing of Mild Steel works including all materials and labour charges like cutting, welding , bending etc for finished item of wok Supply and fixing of Structural Steel including all materials and labour charges like cutting, welding , bending etc for finished item of wok Surface cleaning of metal surfaces by chemical cleaners and then by hand and power tool cleaners and removing dust. After cleaning,applying primary coat with one coat of Zinc rich epoxy primer to a thickness of 40 microns ,followed by finishing coats 2 coats with Solventless Coal tar epoxy with material, labour and all accessories with all leads and lifts CRS Masonry in CM (1:3) 1st Sort Hot dipped Galvanized Iron Chain link mesh 8 gauge - (4.0 mm) as per IS:2721-1979: 2 x 2 (50 mm x 50 mm) - 8 Gauge Supply and erection of 0-500V Digital Volt meter on exisiting panel boardincluding connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS. Supply and erection of 0-100 / 200 / 400 / 600 /1000 Digital Ammeter of size 96x96mm on existing panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMEN Supply and fixing of Three phase Electronic energy meter, 240 V AC, 50 Hz as per IS 13010 upto 40 A range with 200% overload capacity complete with connections etc., complete on the existing board.MAKES : CONZERVE / ELMEASURE/ MECO/HPL/ HAVELLS Supply and erection of LED indication lamps on the existing panel board,including connections etc., complete.Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms. Filteration of transformer oil as per ISS specifications filters to di electric strength above 40 KV at site. Transformer oil tested as per IS-335 - 1972 (per Ltr) Supply of heavy duty long barrel aluminium lugs confirming to I.S specifications suitable for 400 Sq.mm cable etc complete with nuts,bolts and washers.Makes: DMI / Jainson / Dowels or equivalent make as approved by the department Supply of heavy duty long barrel Aluminium lugs confirming to I.S specifications suitable for 240 Sq.mm cable etc complete with nuts, bolts and washers.Makes: DMI / Jainson / Dowels Supply and erecting approved make 11KV, 5KA metal oxide lightning arrestors suitable for 11 KV supply with necessary materials on existing cross arm. Supply of 400A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Supply and fixing of 250A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL /Havells / Siemens / Indo Asian Supply & Fixing of D.O.L Starter 250V, Single phase, 50Hz. With SS enclouser comprising of contactor with bi-metallic relay with necessary push buttons, etc.complete suitable for 5 HP Motor Makes: Siemens / Crompton / L&T / BCH. Supply of 32A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Carryout routine maintenance, servicing and testing of 630A to 1000A L.T. ACB by cleaning fixed contacts ,moving contacts and arc chutes including servicing and putting the ACB in perfect working condition after getting all relay and ON ,OFF mechanism etc done with only manufacturing companies Supply and erection of approved make 11 kV Outdoor type gang operated Air break switch of 400 A capacity with 3 post pin type insulator per phase, mounted in Horizontal/Vertical position with necessary channels on cross arms with necessary channels on cross arms with adequate length of C class GI pipe for operating handle provided with Lock & Key at suitable height from ground level with necessary clamps. Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). Carryout routine maintenance and servicing of LT.Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power brower and servicing the contacts, tightening the connection of incoming and outgoing cables, and clicking the operating.machanism for smooth functioning of switches and putting them in smooth working condition. Supply and fixing of 15.0 KVAR rating capacitor duty Contactor Supply and fixing of 25.0 KVAR rating capacitor duty Contactor Supply and Run of 50 mm x 6mm G.I. strip including cost of all accessories and labour charges etc., complete Supply and erection of Panel mounting cubical type 32A TPN 415V, 50 Hz. switch disconnector fuse unit complete with front drive mechanism with door inter lock,padlocking arrangement etc., complete with fuse links on existing control panel.Makes : L&T / SCHNEIDER / C&S / ABB / SIEMENS Supply,fixing and transportation of 43 / 45 W +/-10% (>=4500 Lumens) LED Street light Body made of high grade pressure die – cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >100 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor must furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM / Panasonic / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Supply of 240 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply of 400 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply and erection of LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing panel including connections etc., complete. MAKE : KAPPA Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II) Supply of 11 KV/22 KV Hand gloves S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 40 mm NB Size. S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size. S & F GI Union 40 mm nominal size 1st Quality S & F GI Union 25 mm nominal size 1st Quality Supply of Grease Supply of Packing Rope to the work site. Supply of Grease gun of 1 kg capacity. Complete dismantling of DV 40x40 vacuum pump, over hauling with replacement of pump bearings-2 Nos. Pump shaft gun metal bushes , pump glands, reconditiong of port plates, impeller lock nuts , studs, wheel bearing grease assembling of pump erection on base plate, correct alignment of pump and motor, successful trial run at site including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incidental charges etc. complete Supply and fixing of PH316 UNIQUE make coupler made of rubber Supply and fixing of Packing Studs to the work site including labour charges, etc., as directed by Engineer- in- Charge. Supply and fixing of Star and Delta Contactor in panel board, L&T MNX 265 Complete dismantling of (300mm-500mm dia) NRV. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges from scheme to workshop and vice versa and all other incidental charges etc. complete Complete dismantling of (300mm-500mm dia) Sluice Valves. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incedental charges etc. complete Complete repairs to 100mm dia Aircushion Valve and fixing including all other incidental charges etc. complete Complete repairs to 600mm dia Zero velocity valves and all other incidental charges etc. complete Complete repairs to 200mm dia Air Valves and all other incidental charges etc. complete Repair of 600mm Dia Expansion joint in Pressure main Complete Dismantling,Overhauling of WPIL make HCF pump run by 210 HP by replacing with new sleeves, bearings,impeller rings, chucknuts etc and aligning the pump true to the alignment of motor and successful trial run at site including transportation charges from site to work shop and vice versa Rewinding of Electric motor of 210 HP, 3Phase up to 1485 RPM squirrel cage induction motor with copper wire, for required IR values including minor repairs, hot air blowing lubrication of ball bearings, bush bearings and erection on base plate, correct allignment of pump and motor, testing of motor for original speed etc. trail run at site,including cost of materials, labour charges transportation charges of motor from scheme to workshop, workshop to scheme and all other incidental charges etc. aas directed by Engineer in charge. Supply and fixing of new Terminal Plate for 210 HP Motor ABB make Supply and fixing of 6316 C3 - 6319 C3 bearings set to the motor Supply and fixing of Thermal Overload Relay- CT ratio set (Make: L&T) MN12 9-15 Amps Supply of Timer ET 100 (L&T) Complete Servicing of 11 KV, 630 A, 25kA Outdor type Load Break switch replacing of damaged outgoing/incoming insulators, servicing the spring charge mechanism, Tighten the bus bar connections, Replacement of Indicator lamps and putting the Load Break Switch in perfect working condition after getting all relay and ON,OFF mechanism etc done with only manufaturing companies Painting to Transformer Yard pole structure after duly cleaning existing metal surfaces Supply and fixing Panel board lock Internal wiring inside Pump House 6 mm rubber flange for packing
Contract Date: Ref. Documents Contract Value : 23.60 Lakh
Government Departments No of Bidders 1
Contract Date: Jun 29, 2026 Contract Value : 22.51 Lakh
Government Departments No of Bidders 25
maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 56,000
Statutory Bodies & Commissions/Committees No of Bidders 2
Contract Date: Ref. Documents Contract Value : 1.35 Lakh
Government Departments No of Bidders 3
Andaman And Nicobar Islands View Result →
6.
Public Administrative Department #11055239 AOC
Flood Prepardness During North East Monsoon At Ward No.32, 33, 49, 50 In Zone No.4- Hire Charges of Genset for Flood Relief Centres including cost of Hire charges, Fuel charges,Operating chargesand conveyances of all charges etc complete as per the standard specifications 2 GENERATOR - Starting and Ending Day 62.5 KVA 3 GENERATOR - Starting and Ending Day 125 KVA 4 GENERATOR - Intermediate Days 62.5 KVA 5 GENERATOR - Intermediate Days 125 KVA 6 Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete. 7 JCB 8 Poclain 9 Dewatering using diesel Engine pumpset including Hire charges,cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc complete 10 3 HP 11 5 HP 12 10 HP 13 15 HP 14 20 HP 15 40 HP 16 Cutting for Fallen tree on the roads during Rainy Season and operating to dewatering of pump ( Due to Wind) only Labour charges for Cutting etc complete as per standarrd specifications (Mazdoor category I ) 17 Hire Charges for Light commercial Vehiche for transport charges for Municipal Oil Engine withincluding hire charges Fuel charges transit charges, loading,unloading andoperator wages etc complete 18 Hire Charges ofHigh commercial Vehiche for transport charges for Cutting Treeswithincluding hire charges Fuel charges transit charges, loading,unloading andoperator wages etc complete 19 Hire Charges of40HP tractor with trailer for transport charges for removing of Trees with including hire charges Fuel charges transit charges, loading,unloading andoperator wages etc complete 20 Hire Charges for 40HP tractor breaker in dismandiling RCC/PCC Works including Hire charges, cost of Diesel, Engine oil,operater, labour charges, conveyance ofand fuel to site and back, loading, unloading and any other incidental charges etc complete
Contract Date: May 11, 2026 Contract Value : 18.33 Lakh
Local Bodies No of Bidders 2
Contract Date: May 08, 2026 Contract Value : 1.16 Lakh
Local Bodies No of Bidders 2
8.
Public Administrative Department #10714170 Price Bid
Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan EARTH WORKClearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. 2 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil. Upto 3.0 m depth. 3 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m. 4 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 In ordinary rock. Depth upto 1.5 M. 6 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Upto 1 Km 8 Stone, boulders, gravelly materia 9 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of IRC:78 and clause 2200 of MoRT&H specification. 12 CONCRETE WORK 13 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 REINFORCED CEMENT CONCRETE 16 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix). 17 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 19 Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 Providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Suspended floors, roofs, landings, balconies and access platform. 25 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 Columns, Pillars, Piers, Abutments, Posts and Struts.22.1.5 27 Stairs, (excluding landings) except spiral-staircases. 28 Extra for shuttering in circular work (20% of respective centring and shuttering items). 29 Edges of slabs and breaks in floors and walls. Under 20 cm wide. 30 Weather shade, Chajjas, corbels etc., including edges. 31 Add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 33 BRICK / STONE MASONERY WORK 34 Brick work with FPS bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 35 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand). 36 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:3 (1 cement :3 coarse sand). 37 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 38 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Above 3601 Cm2 Slabs. 40 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Moulding. 41 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles 44 Providing and fixing Motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. Size 200 x 300mm. 45 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm. 46 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm. 47 Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). Size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone. 51 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 52 ROOFING 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase. 54 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 60 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). Design on outer plaster. 62 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 64 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. 66 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8193, density 16kg/m3 , 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 68 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. 70 Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H Specification including all material, labour, machinary etc. 71 Fillar joint with 20m thick compressible fibre board. 72 Fillar joint with Joint sealing compound with coarse sand and 6 %bitumen by weight. 73 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: Hot finished seamless type tubes. 74 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 76 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. 77 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure A : 30 mm thick Decorative teak veneer both side. 79 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). Decorative teak veneer both side. 80 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Rectangular or square. 81 Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area ofthe shutter to be measured). 82 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long. 83 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded Pre-laminated PVC C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing (for W.C. and bathroom door shutter). 85 ALUMINIUM WORK 86 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). 87 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron). 88 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basicitem) : With float glass panes of 5.50 mm thickness. 90 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. 91 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. 355 X 19 mm. 92 INTERIOR WORK 93 FALSE CEILING 94 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, 95 Sanitary Items 96 Plumbing 97 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 101 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 106 25 mm nominal bore Horizontal 107 25 mm nominal bore Vertical 108 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 Sanitary 110 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : Upto 300 mm dia. 111 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 Supplying pig lead at site of work. 118 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 121 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With bricks class designation 75 122 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With bricks class designation 75. 123 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design With bricks. 124 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design With bricks 125 Fixtures 126 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. 127 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers. 128 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 Rectangular shape 453x357mm 131 Rectangular shape 1500x450 mm 132 Providing and fixing 100 mm sand cast Iron grating for gully trap 133 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 136 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 137 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade 138 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 140 Internal work - Exposed on wall 15 mm dia. nominal bore 141 Internal work - Exposed on wall 20 mm dia. nominal bore 142 Internal work - Exposed on wall 25 mm dia. nominal bore 143 Internal work - Exposed on wall 32 mm dia. nominal bore 144 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 WATER HARVESTING SYSTEM 166 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia Nominal bore 167 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia 168 Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 Providing & lowering of G.I. flange pipe B Class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 ELECTRICAL G-SCHEDULE 172 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 Short point (up to 3 mtr.) 174 Medium point (up to 6 mtr.) 175 Long point(up to 10 mtr..) 176 Wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its accessories, round tles,18 SWG M.S. box with earth terminal, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 Short point (up to 3 mtr.) 178 Medium point (up to 6 mtr.) 179 Long point(up to 10 mtr..) 180 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 On board 182 Short point (up to 3 mtr.) 183 Medium point (up to 6 mtr.) 184 Long point(up to 10 mtr..) 185 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 RG - 6 198 RG -11 199 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS-112C &113 C of approved make in existing surface or recessed conduit/casing capping. 200 Unarmoured 2 pair 201 Unarmoured 10 pair 202 Unarmoured 20 pair 203 Unarmoured 50 pair 204 Jelly filled armoured (PIJF) 5 pair 205 Jelly filled armoured (PIJF) 10 pair 206 Jelly filled armoured (PIJF) 20 pair 207 Jelly filled armoured (PIJF) 50 pair 208 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (Three phase) Per phase isolation 209 2+8 Way 210 2+12 Way 211 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 Sq. mm 4 core 213 4.0 Sq.mm 4 core 214 6.0 Sq.mm 4 core 215 10.0 Sq.mm 4 core 216 16.0 Sq.mm 4 core 217 25.0 Sq.mm 3.5 core 218 35.0 Sq.mm 3.5 core 219 50.0 Sq.mm 3.5 core 220 70.0 Sq,mm 3.5 core 221 95.0 Sq.mm 3.5 core 222 120.0 Sq.mm 3.5 core 223 150.0 Sq.mm 3.5 core 224 240.0 Sq.mm 3.5 core 225 300.0 Sq.mm 3.5 core 226 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. Hot Dipped Galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating With pipe in pipe technology with 80-100 micron G.I. coating G.I. pipe 3000 mm long , 80/40 mm , terminal 14 mm G.I. strip 247 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 SWG copper Wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm G.I. ( Hot Dipped) Strip 252 25mm x 6mm G.I. ( Hot Dipped) Strip 253 P & F of IP20 LED Recessed/ Surface Mounted Round/ sqaure Non Dimmable Downlight with die-cast aluminum housing & Heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. ( supplied together with luminaire) Power consumption of =< 7w/10w/8w/12w/15w/18W with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / Watt or 100 lm / Watt output suitable to replace 1x18W/ 2x18w/2x26w CFL downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE Compliance. 254 Recessed mounting LED Downlight 18/20W 255 Surface Mounting LED Downlight 18/20W 256 P & F of IP20 LED Ceiling/ Recessed/ suspended mounting light fixture made form CRCA sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards.(integral driver). Power consumption of 40 W/50W/60W, 3000/3300/4200 lumens, system lumen efficiency of 70-80 lm / Watt output suitable for 2x36W FTL/ 2x36w CFL/3x36w CFL light fixtures, life time of 50000 burning Hours with 70% intial Lumens maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE compliance. Surface Mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover 257 P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K& 6000°K. 4 LED Tube shape fixture 18W. 258 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries LED street light fixture 150 watt 259 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 Mtr. 260 Supply, Installation, Testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformers described as above and as per the following continuous rating. 315KVA 261 Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25KA/3 and IAC A-FLR for 25kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. 262 SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged 250 KVA at 0.8 pf 415V 50Hz 3-?. 263 Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. 264 Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 FIRE ALARM G-SCHEDULE 266 SITC of microprocessor based 2 - wire loop (each loop accessing 90 addressable units ) Fire Alarm Control Panel. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. The Panel shall also be able to give voice announcement to individualized speakers. The Panel shall have built in sounder, Maintenance Free Batteries of minimum 15 Ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. Loop cards, LCD unit to indicate Fire / Fault Signal of individual unit, built in-built / external printer, to log all incoming data etc complete in all respect. 2-LOOP. 267 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: Analogue addressable type 268 SITC Automatic commendable Control Switches for shutting downAC Plant, Power Supply, Gas Supply etc. Response Indicators. 269 SITC Fault Isolators for isolating shorted, dead wire and loose circuits between two successive Fault Isolators with automatic resetting arrangement. Analogue addressable type. 270 FIRE FIGHTING G-SCHEDULE 271 Sub Head - I - (Wet Riser System - Pumping Equipments)SITC of electric driven Sprinkler / Hydrant pump Suitable for automatic Operation consisting of the following-(A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. (C) Common bed plate fabricated from mild steel channel or cast iron type1620 LPM at 70 Mtr Head ( 50 HP Motor) 272 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge:(A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate, Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump setC) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 LPM at 70 Mtr Head ( 50 HP Engine) 273 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 180 LPM at 70 Mtr (15 HP). 274 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 275 Providing & fixing 100mm dia pressure Gauge on Pump DeliveryLine complete with shut off cock. 276 SITC of pressure switches for Main, Jockey, and standby pumps,including necessary wiring UPTO control panel and stop valve. 277 Sub Head - II - (Hydrants System) 278 Providing and fixing single headed hydrant valves with flanged inletISI marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to IS : 5290 279 Providing . 63 mm dia 15 M long reinforced rubber hose pipeconforming to IS : 636-1962, Part –A & ISI marked with Gun Metalmale & female coupling wire wound with the pipe. 280 Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSECABINET suitable for accommodating hydrants made of not lessthan 16 swg. M. S. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 Nobranch pipe. 281 Providing and fixing Swinging Drum type hose reel ISI marked 30M(L) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 Providing and fixing ISI marked Three Way fire Brigade Inlet to wetRiser with non return valve complete in all respects 283 Providing, fixing, jointing and testing of Heavy Gauge (C class ) MSPipe ISI marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. Complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of Red Oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 Sub Head - III - (Piping, Valves and Accessories) 288 MS (Medium duty B class) pipe with cleaning,wrapping and coatingof the pipe as per IS; 10221 in all kind of soil at 1.0 M depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Discand Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 Providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : Pendant type with quartziod bulb, operating temperature at 68 deg Cas per specifications. 302 Providing & fixing 10 SWG chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofSprinkler piping with the false ceiling. 303 Sub Head - III - (Piping, Valves and Accessories) 304 Sub Head - IV (Fire Electrical Control Panel) 305 Supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, PVC tape etc of followingsize 306 1.5 Sq.mm 307 10.0 Sq.mm 308 35.0 Sq.mm 309 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 BOUNDARY WALL G-SCHEDULE 311 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 312 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 315 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 316 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 317 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 319 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing. 320 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) 321 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 EARTH WORK 323 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil Upto 3.0 m depth. 325 EXTERNAL DEVELOPMENT 326 Compacting original ground 327 Loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8-10 tonne to meet requirement of table 300-2 for subgrade construction as per MoRT&H specification clause 305.3.4. 328 Loosening and recompacting original ground below embankment including Loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling by vibratory roller 8-10 tonne so as to achieve minimum dry density as given in table 300-2 for embankment construction as per MoRT&H specification clause 305.3.4. 329 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 CEMENT CONCRETE PAVEMENTS 331 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30. 333 Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer. 334 Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. 335 Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 336 Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. 300 mm internal diameter. 337 Horticulture Work 338 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction. 339 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 Ficus panda 341 Tecoma capensis ( Ratanjot) 342 Clerodendron inermii ( Choti Aari) 343 Tabernaemontana variegated ( Chandni) 344 Hamelia patens ( Firebush, Thal Kamal) 345 Hibiscus variegated ( Guddal) 346 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 Wedelia trilobata ( SunFlower Family) 348 Alternathera green (Parrot Leaf) 349 Iresine herbstii (Blood Leaf) 350 Ophiopogon Black ( Lily Turf, Mondograss) 351 Asparagus myerii (Fox Tail) 352 Lantana sellowiana 353 Rhoeo spathacea Compacta‘ ( Oyster, Boat Lily) 354 Golden duranta 355 Pennisetum setaceum (Fountain Grass)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
14.
Housing Urban and Rular Development #10411374 Price Bid
Tender For Rejuvenation Of 2 Mi Tanks At Kallakurichi Block In Kallakurichi District; 1 Rejuvenation of MI Tank Melur Eri in Melur Panchayat 2 Clearing the Scrub jungle 3 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete 4 Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete.having width up to 3m (W0087) 5 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete 6 Providing Boundry Stone 7 Provision for Name Board 8 Rejuvenation of MI Tank Katteri in Varadhappanur Panchayat 9 Clearing the Scrub jungle 10 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete 11 Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete.having width up to 3m (W0087) 12 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete 13 Providing Boundry Stone 14 Provision for Name Board 15 GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column BB for all works in this package}(Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
15.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
16.
Drinking Water Supply and Sanitation #10331064 Price Bid
tender for Withdrawing damaged p/m set from defunct tube well and Supply & Installation of submersible pumping machinery for T.W. No.-I (Replacement tube well) and different electro-mechanical works for P.H No.-I & II at BARWA w/s scheme under CMD, PHE Dte., Dist.- Purba-Bardhaman. Sl. No. Item Description 1 Withdrawing of damaged 10 HP submersible pump motor set from defunct tube well (T.W No.-1) along with 80 mm dia M.S column pipes by necy. arrangement & skilled labour after disconnection of power line & delivery pipe line as per direction of EIC& kept at site. 2 Work at T.W No.-I (Replacement tube well) 3 Supply and delivery at site submersible pumping machinery directly coupled with wet winding type submersible motor having the following specification pump.Duty Condition : 54 m3 /hr. Head : 52 mtr. Motor : Submersible type 3 Ph. 50 Hz. 400V + 10%, Star DeltaImpeller : GM /SS /CromesteelShaft : Stainless SteelMotor winding : Wet Type.Pump outlet - 75/100 mm.RPM - 2900(+1%) Suitable for size of tubewell : 250mm x 150mm.Pump set should be energy efficient and equivalent BEE standard energy star rating (3-5) as per IS – 8034:2002Make : KSB / Texmo / PLUGA / BG / PHED approved make(Test certificate, warranty certificate along with characteristic curve should be submitted at the time of delivery.) 4 Supply & delivery of following materials - 5 80mm. dia uPVC column pipe 7.1mm. thick having 70mm. long 8TPI threaded both side with heavy type one socket & O ring biax technology with wiring lock system non corrosive, high tensile having I.S.O. 9001 standard. (Make : Ashirbad/ Oriplast/ Raksha/ Approved Make). 6 i) 10ft. long (3 mtrs) 7 ii) 5ft. long (1.5 mtrs) 8 iii) 80mm. dia. top & bottom adaptor 9 iv) 3 dia. X 5 ft long M.S. (7.1 mm Thick) Column pipe having both side 11 TPI Thread and Socket. 10 4 sq. mm. 3 core copper 1.1 KV grade PVC insulated water proof flat submersible cable.(Make : Finolex/ Gloster/ Mescab/ Currency/ Netco/ Polycab/ Approved Make) 11 Heavy type suitable dia M.S. suspension clamp for above column pipe along with nuts, bolts and washers etc 12 Split type M.S. fabricated tube well cover for suitable dia. tube well housing pipe with necessary fitting arrangement along with of column pipe, Air pipe, rope of anti snapping device & cable entry gland etc. 13 Pressure gauge 102 mm. dia and 7 kg. /cm2 range, brass cocks and fitting complete (Make- H.Guru) 14 Making safety device for above pump by supplying 3 nos. suitable size MS clamp/ MS Cage and 1 dia nylon rope of required length including supplying nuts, bolts, and other materials as per direction. 15 80 mm dia CIDF non rising Sluice Valve (PN-1.0) with flange ends drilled (Make : IVI/ IVC/ Cair/ Hazra/ Upadhya/ Jupitor Engg co.) as per relavant I.S. 16 80 mm dia CIDF single door swing type Non-return Valve (PN-1.0) with flange ends drilled (Make : IVI / IVC /Cair/ Hazra/ Upadhya/ Jupitor Engg co.) 17 Ø3 X 1.0 mtr CIDF Pipe 18 Ø 3 X 2 ft CIDF Pipe 19 Ø 3CIDF Bend 20 Ø 3 M. S. Cross 21 Steel Plug, M. S. Nipple, Flange, Nuts, Bolts etc 22 32 mm dia uPVC Pipe (Sch-40) (Make- Ashirvad/ Oriplast/ Supreme/ apprvd make) 23 32 mm dia uPVC Union (Make- Ashirvad/ Oriplast/ Supreme/ apprvd make) 24 32 mm dia uPVC Elbow (Make- Ashirvad/ Oriplast/ Supreme /apprvd make) 25 32 mm dia uPVC Coupler (Make- Ashirvad/ Oriplast/ Supreme /apprvd make) 26 Installation of above pump motor, valves, CIDF, specials for making delivery & washout pipe line and power line connection to the existing panel etc as required to complete the jobsincluding supply of cable gland, sockets as required for the work as per direction of EIC. 27 Making brick pillar (size- 0.25 x 0.25 x 1 Mtr/Suitable hight) for supporting of valves and pipes with plaster & neat cement finish as per direction of EIC. 28 Making of tubewell foundation (size- 3x 3x 3.5 approx) as per site situation including supply of necessary materials as bricks, sand, cement, stone chips etc. with plastering & neat cement finishing to complete as per direction. 29 Work at P.H No.-I & II 30 Labour charges for dismantling the damaged main switch, starter, busbar cum panel box, MS angel frame, chlorine machine, 220 volt & 440 volt wiring, internal & outside lighting set, other usable accessories from damaged pump house and manual carrying to PHE civil room by engaging skilled and unskilled labour as per direction of EIC for P.H No.-I & II 31 Supply and delivery at site following items- 32 100 Amp. 440 V, 50 Hz. TPN Main switch with rewireable type porcelein fuse unit (Make: Havells/ Standard/ PHED approved) (1 no for each P.H No.-I & II) 33 63 Amp. 440 V, 50 Hz. TPN Main switch with rewireable type porcelein fuse unit (Make: Havells/ Standard/ PHED approved)(for P.H No.- II) 34 Star-delta submersible pump starter with 3-position selection (with auto switch) with MCB (short circuit protection), 25Amp. contactor & overload relay range: 13-20 Amp. [Make : BCH (Model- Citation)/ PHED approved ] (for P.H No.- I) 35 25 sq. mm.1.1 KV grade. 3.5 core Al Armoured XLPE cable conform to IS 1554/7098(part-I) 1998(Make : Gloster/ Havells/ Mescab/ Currency/ Polycab/ Crystal/ Approved Make) (for P.H No.- II) 36 10 sq. mm FR PVC insulated (Usheathed) single core multi strand cable with copper conductor upto 1.1 KV grade, IS: 694[Make- Mescab/ Finolex / Havells] (for P.H No.- I) 37 TP MCB 16Amp, 10KA for chlorination (Make: ABB/ Siemens/ L&T/ PHE approved make) (1 no for each P.H No.-I & II) 38 Phase Indicating Lamp 39 Ammeter selector switch, 10 Amp (Make : Kaycee/ Approved make) 40 Installation of above supply items (Sl no.-11) & usable busbar, main switch etc. and S&F 32 mm dia PVC Rigid Conduit FR [Precision Make] on wall with saddles and other accessories as required and mending good damages to building works from kit kat to main switch,busbar, starter etc (approx 10 mtr length) for protection existing 440 volt copper cable line & making all electrical connection with testing of the whole installation as per entire satisfaction of EIC 41 Makingearthing arrangement(for P.H No.-I & II) 42 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 43 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 44 Extra for treatment of soil by using salt & charcoal or coke forplate electrode. 45 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 46 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 47 Distribution wiring in 1.1KV. Grade, (2X1.5mm2) single core stranded FR PVC insulated & unsheathed copper wire (approved make) in suitable size PVC casing capping (Precision make) with (1.5 Sqmm) single core stranded FR PVC insulted & unsheathed copper wire for ECC, including necessary PVC clips, fittings etc. to light/fan point with piano key type switch (anchor make) fixed on pvc/sheet steel fabricated switch board with Perspex/bakelite top cover on wall including necessary connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] 48 a) average run 4. 5 mtr. - 49 Supply and delivery of following materials- 50 16A DP MCB with enclosure (Make- Havells/ Siemens/ ABB/ L&T) 51 4 long 20 watt LED tube light set white colour (Make -Philips/ Havells) 52 9 watt LED lamp (Make- Philips/ Havells) 53 14 watt LED lamp (Make- Philips/ Havells) 54 Bulkhead light fittings on wall (Make- Bajaj/ Havells/ approvedmake) 55 Supply and fitting fixing of Ceiling fan (Make: Usha /C.G / Havells/ approvedmake) 1200mm. sweep complete with rubber bush, nut, bolt etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. (for P.H No.-I ) 56 Supply and fitting fixing of 90 watt. LED light fixture set[Make: Philips (Type- BRP033)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. (for P.H No.-I ) 57 Supply and fitting fixing of 45 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. (for P.H No.-II ) 58 Supply & delivery at site following spares for repair & reorientation of chlorine machine for P.H No.-I : 59 15 mm dia braided hose pipe 60 Tail Piece (200 mm long) 61 15 mm Short Piece (100 mm) 62 15 mm dia GI Tee 63 15 mm dia NRV 64 15 mm uPVC Pipe (Sch 40) (Make- approved make) 65 15 mm dia uPVC Male Adaptor plastic threaded (Make- approved make) 66 15 mm dia uPVC Female Adaptor plastic threaded (Make- approved make) 67 15 mm uPVC Ball Valve (Make- approved make) 68 uPVC Blue Medium Solvent Cement (59 ml) 69 Mobil oil 70 Reassemble the above chlorine dozing pump part by part with newly supplied materials (from sl no.-17) including old servicable spares with supply of fast moving spares parts such as gland packing, clamp, nut, bolts etc. as required and testing complete as per direction of EIC. 71 Add. GST@18% 72 Add. Cess@1%
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
17.
Tourism #10301450 AOC
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. All Kinds Of Soil , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer In Charge. , Carriage Of Debris From The Site Of Work Like Excavated Earth,Demolished Stones, Rock Boulders,Vegetation Etc, And Disposing The Same To A Distance Of 1.00Kms.Including All Lead And Lifts Etc. Complete By Means Of Tipper Truck( Contractor To Indentify The Site Of Disposal At His Own Cost And Risk). , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg/ Cm2 (Wire Cut Bricks). In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Exposed Decorative Laterite Masonary Of Stones As Specified And Laid As Directed By Architect In Cement Mortar 1: 4 (1Cement: 4 Coarse Sand ) , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) Above Plinth Upto Level V. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing .All Works Upto Plinth Level , Providing & Laying Cement Concrete 1:3:6 (1 Cement: 3 Coarse Sand: 6 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In:All Works Upto Plinth Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) All Works Upto Plinth Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) ..In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Structs Etc. Upto Floor Five Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) ..In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases Upto Floor Five Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates I) Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only + Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) Where Inclination To The Horizontal Exceeds 30° Requiring Shuttering On The Underside & Upperside If Required (Only Area Of Underside Shall Be Measured For Payment) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) )(Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing Woodwork In Frames Of Doors, Windows, Clerestory Windows Trusses & Other Frames Wrought Framed And Fixed In Positon.:Second Class Indian Teak Wood , Providing And Fixing 38 Mm Thick Panelled Glazed Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Window Including Black Enamelled Iron Butt Hinges With Necessary Screws: Second Class Indian Teak Wood , Providing And Fixing Louvers 50 Mm Wide In Grooves In Clerestory Window Frames Excluding The Cost Of Frames.:Second Class Indian Teak Wood 12 Mm Thick , Providing Flat Iron Hold Fast 40 Cm Including Fixing To Frame With 10 Mm Dia Bolts, Nuts And Wooden Plugs And Embeded In Cement Concrete Block 30 X 10 X 15 Cm 1:3:6 Mix (1 Cement: 3 Coarse Sand: 6 Stone Aggregate 20 Mm Nominal Size.: 40 X 3 Mm Flat Iron Hold Fast, 15 Cm Long , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws.:Plain Grill , Providing And Fixing Bright Finished Brass Butt Hinges With Necessary Screws Etc Complete: 125 X 70 X 4 Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete: 200 X 10 Mm , Providing And Fixing Bright Finished Brass Handles With Necessary Screws Etc Complete: 125Mm , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete:250 X 16 X 5 Mm , Providing & Fixing Bright Finished Brass 100 Mm. Mortice Latch & Lock & A Pair Of Levers, Handles With Necessary Screws Etc. Complete (Indian Make Of Approved Quality). , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Brass Hydraulic Door Closer Of Make Everest Universal 68 Or Equivalent With Necessary Screws And Fittings Complete. , Providing And Fixing Factory Made Panelled Door Shutter Fabricated Out Of Second Class Teak Wood With Styles Top And Middle Rail, Lock And Bottom Rail With Navopan Or Equivalent Weather Resistant Melamine Faced Prelaminated Twin Particle Board - Bonded With Bwp/Bwr Exterior Grade Synthetic Resin As Per Is - 3087 (1985)Type I Including Anodised Aluminium Butt Hinges With Necessary Screws Etc. Complete.: 12 Mm Thick Panel (Iii) 30 Mm Thick , Providing And Fixing Flush Door Shutter Of Solid Core Melamine Face Three Layered, Prelaminated Wood Based Particle Board Exterior Grade Having Shade Of Choice On Both Sides (Ptx) Or Having Shade Of Choice On One Side And Balancing Lamination On The Other Side (Plx) As Per Is 3087 (1985) Type I On The Edge Of Novopan Or Equivalent Bonded With Bwr/Bwp Synthetic Resin With Second Class Teak Wood, Lipping Of Section Of Size 12 Mm X 30 Mm Flange And 18 Mm X 10 Mm Web (18 Mm Deep) Fixed Into 18 X 10 Mm Groves Of Shutter With Water Resistant Adhesive And Fully Threaded G.I. Screws 50 Mm Not More Than 450 Mm Centre To Centre Including Anodized Aluminium Butt Hinges With Necessary Screws Etc. Complete.:Natural Teak On Both Faces:2) 30Mm Thick , Frp (Fiber Reinforced Polymer) Frames With Wood Finish Manufacture, Supply And Installation (With Anchor Fastener) Of Epee Or Equivalent Goan Make Frp (Fiber Reinforced Polymer) Frame Of Cross Section As Per Options Below With Right Angle Joint And Frp (Fiber Reinforced Polymer) Laminate Made From 450 Grams Per Sq.Mts (Gsm) Chop Strand Glass Fiber (Matt) And Unsaturated Polyester Resin With Viscosity Range Of 400/450 Centipoises Per Second (Cps). The Core Of Frame Would Be Filled With Seasoned Wood As Infill Material. The Slot Of Frame For Door Resting Will Be Of Suitable Width So As To Take Specified Thickness Door. The Frame Will Be Water Proof As Well As Mild Acid/ Alkali Resistant Manufactured In An Iso 9001- 2015 Certified Company. Accessories:I) S. S. Hinges 4 - 3 Nos Ii) S. S. Latch - 1 No Iii) Tower Bolt 5 - 2 Nos Iv) Handle 5 - 2 Nos Shutter Thickness: A) 30Mm , Providing And Fixing Anodized Aluminium Shutters In Accordance With The Specification Annexed With Goa Schedule Of Rates (2004) Vol & Ii Including All Taxes, Transportation, Scaffolding And Handling Etc. Complete As Per Direction Of The Engineer-In-Charge: Windows With Two Sliding Shutters Using 18 Mm Series Shutters Section.:Figured Glass , Providing And Fixing Anodized Aluminium Shutters In Accordance With The Specification Annexed With Goa Schedule Of Rates (2004) Vol & Ii Including All Taxes, Transportation, Scaffolding And Handling Etc. Complete As Per Direction Of The Engineer-In-Charge: Adjustable Louvered Windows.:Plain Glass , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand): 20 Mm Thick. , Kotah Stone Slab Flooring Over 25 Mm Thick In Risers Of Steps, Skirtings, Dado & Pillars Laid On 12Mm (Average) Thick Cement Mortor 1:3 (1 Cement : 3 Coarse Sand) & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Polishing Complete. , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete :600X 600 Mm Light Shades , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.:60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.:60 Mm Thick In Grey Colour (M35 Grade) , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Elite Brown , Providing And Fixing 18 Mm Thick Gang Saw Cut,Mirror Polished, Premoulded And Prepolished,Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade,Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand),Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm:Cherry Red , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete.-180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Joint Bracket With 2 Clamps For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr 90 Deg. Elbow With/Without Outlet With 2 Clamps For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing & Fixing Of Metal Tile Ceiling System Comprising Of Tile Of 600Mm Wide And 600Mm Long Manufactured Of 0.6Mm Thick Aluminium Clip-In Perforated 2.5Mm Dia 5.5Mm C/C. The Tile Shall Be Manufactured On Advanced Equipment, Which Includes Several Levelling Stages In The Manufacturing Process. Tile Ends Shall Be Raised With Pips And Stops To Ensure Positive Engagement Into The Spring To Enable For De-Mounting Of Individual Panels. The Tile Sides Shall Be Sufficiently High To Ensure A Minimum Deflection Across The Length Of Tile. All Tiles Shall Be Bevelled Edged. The Tile Shall Be Polyester Based, Powder Coated In White Colour. Tile Shall Be Clipped Into Clip In Profile Of 0.5Mm Thick G.I. The Clip In Profile Shall Be Supported From Slab By Means Of Rigid Suspension Of 4Mm G.I. Rod, Hold On Clamp With Clip. Acoustic Felt: Non-Woven Felt Made Of Glass-Reinforced Fibreglued Over The Perforation For Sound Absorption. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , 20Mm Cement Plaster 1: 3 (1 Cement : 3 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , Neat Cement Punning , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) Extra For Plastering Spherical Ceiling , 20Mm Cement Plaster 1: 3 (1 Cement : 3 Fine Sand) Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level.In One Coat , 12Mm Thick Moulded Cement Mortar Bands In Cement Mortar 1:4 (1 Cement : 4 Fine Sand) Cm Per Meter , Painting One/ Two More Coats With Ordinary Ready Mixed Paint Of Approved Brand & Manufacture In All Shades Except White Or Green On Old Work To Give An Even Shade. , Painting Two Or More Coats (Excluding Priming Coat) With Superior Quality Ready Mixed Paint For Steel Work Of Approved Brand & Manufacture In All Shades On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Wall Painting (One Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On Old Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture(Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting One Or More Coats Of Acryllic Exterior Paint Of Approved Brand And Manufacture(Such As Dulex/ Asian Paints/ Sherwin Willians) On Old Work Including Cleaning The Surface With Water Etc. Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge:110 Mm Dia , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , 1) Grassing With Doob Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms Of Thick Lawn Free From Weeds And Fit For Moving, Including Supplying Good Earth If Needed. (Cost Of Doob Grass Not Included ) 2) In Rows 15 Cm Apart In Either Direction. , Digging Holes In Ordinary Soil And Refilling The Same With The Excavated Earth Mixed With Manure Or Sludge In Ratio Of 2: 1 By Volume (2 Parts Or Stacked Volume Of Earth After Reduction By 20% And 1 Part Of Stacked Volume Of Manure After Reduction By 40%) Flooding With Water, Dressing Including Removal Of Rubbish & Surplus Earth If Any With All Leads & Lifts (Cost Of Manure Or Sludge Of Extra Good Earth If Needed To Be Paid For Separately) Holes 1.2M Dia And 1.2M Deep , Providing And Fixing M.S. Flat Iron Tree Guard 60Cm Dia & 2 M High Above Ground Level, Formed Of 4 Nos. 25 X 6Mm And 8 Nos. 25 X 3Mm Vertical M.S. Flat Iron Rings In Two Halves, Bolted Together With 8Mm Dia And 30 Mm Long Bolts Including Painting Two Coats With Paint Of Approved Brand And Manufacture Over A Coat Of Priming, Complete In All Respects. , Proving And Fixing White Vitreous China Water Closet Squating (European Type W.C. Pan) With Seat And Lid, C.P. Brass Hinges And Rubber Buffers 10 Lts. High Level P.V.C.. Flushing Cistern (Of Approved Make ) With Fittings, Rack Bolts 32 Mm Diameter P.V.C. Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C.. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon. Chain And Pull Complete, Cutting And Making Good The Walls Ad Floors Where Required.:W.C. Pan With White Plastic Seat And Lid. , Providing And Fixing Vitreous China Wash Basin With R Sor C.I.Brackets Painted White,15Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required.:Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing & Fixing (4) 100 Mm Sand Cast Iron Grating For Gully Floor Or Nahni Trap. , Providing And Fixing 600 X 450 Mm Bevelled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Asbestos Sheet Ground Fixed To Wooden Cleats With C. P. Brass Screws And Washers. , Providing And Fixing Toilet Paper Holder :C.P. Brass , Providing & Fixing Liquid Soap Container With C.P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws A)Glass Container , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Flush Valve Nelson/ Similar) Fully Chromium Plated With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vaccu.M Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality :15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality : A)15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality :B)20 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality : C)25 Mm Nominal Bore . , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality :D)32 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality :A)15 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality :B)20 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) Of Approved Quality :A) High Pressure With P.V.C. Floats: 25Mm Nominal Bore , Providing And Fixing Non-Return Valve Of Approved Quality :A)25 Mm Nominal Bore , Providing And Fixing Non-Return Valve Of Approved Quality : B)32 Mm Nominal Bore , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996. C) 1000 Lit. Capacity , Providing And Fixing Square-Mouth S.W. Gully Trap Grade ‘A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of Cover To Be Not Less Than 4.53 Kg). And Frame To Be Not Less Than 2.72 Kg As Per Standard Design : A)100 X 100 Mm Size P Type , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. : D)Inside Size 60 X 60Cm And 60Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610mm Internal Diameter Total Weight Of Cover And Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg). , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. , Providing And Fixing Rigid Pvc S.W.R. (Soil, Waste & Rain Water) Drainage Pipes Of Approved Including Lubricant Etc. Complete (Single/Double) Socketed: A)110 Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating Etc Complete Bend With Door :A)100 Mm Dia , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door: A)110 Mm Dia , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door :A)110 Mm Dia , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110 Dia A)110Mm Dia , Providing And Fixing R.P.V.C. Vent Cowl: A)110 Mm Dia , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bib Cock Short Body Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flance Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Concealed Stop Cock With Slinding Flance 15 Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5 Pipe). A)15 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5 Pipe). B) 20 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. A)15 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. B)20 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. C)25 Mm Dia Nominal Outer Dia Pipes. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Confirming To Is: 15778 Having Thermal Stability For Hot And Cold Water Supply Includng All Cpvc Plain And Brass Threaded Fittings Cpvc Solvent Cement, Trenching, Refilling And Testing Of Joints Complete As Per Firectionof The Engineer In Charge.(External Work (Heavy Duty Sdr 11 Pipe) C)25 Mm Nominal Outer Dia Pipes. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Confirming To Is: 15778 Having Thermal Stability For Hot And Cold Water Supply Includng All Cpvc Plain And Brass Threaded Fittings Cpvc Solvent Cement, Trenching, Refilling And Testing Of Joints Complete As Per Firectionof The Engineer In Charge.(External Work (Heavy Duty Sdr 11 Pipe) D)32 Mm Nominal Outer Dia Pipes. , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. A)Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainles Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. I)Sch-80(Blue)/(White) A)20Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. I) Sch-40(Blue)/(White) A)20Mm Outer Dia. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bib Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 A)15Mm Nominal Bore , Providing Anti - Termite Treatment To Buildings Conforming To I.S.S. 6113 Part Ii 1971 (Revised) Including Adopting Precautions For Health Hazards And Safety Measures As Required Therein With The Cost Of All Materials, Chemicals, Plants, Equipments Required For The Treatment And Furnishing A Guarantee For A Minimum Period Of 10 Years From The Date Of Completion Including Eradicating Any Infestation Of Termite Free Of Cost During The Guaranty Period Complete. (Thepayment Will Be Made On Plinth Of The Building). A)Pre-Construction , Providing Anti - Termite Treatment To Buildings Conforming To I.S.S. 6113 Part Ii 1971 (Revised) Including Adopting Precautions For Health Hazards And Safety Measures As Required Therein With The Cost Of All Materials, Chemicals, Plants, Equipments Required For The Treatment And Furnishing A Guarantee For A Minimum Period Of 10 Years From The Date Of Completion Including Eradicating Any Infestation Of Termite Free Of Cost During The Guaranty Period Complete. (Thepayment Will Be Made On Plinth Of The Building). B)Post Construction , Pvc False Ceiling Grid Type : Providing And Fixing Pvc False Ceiling Consisting Of 600Mm X 600Mm, 5Mm(±0.25) Thick Plain Pvc Sheet Of 600 Kg/Cbm Density Manufactured By An Iso- 9000 Certified Company, Used As Panel Insert In A Frame Work Made Using Anodized Aluminum T- Section Of Sizes 1 X1 (25X25mm, 19 Gauge Or 1Mm Thick) In Square Pattern Of Grid Sizes Of 2X2(600X600mm). The Aluminum Frame Work Is Supported From The Ceiling With The Help Of J Hook And G.I. Wire / 6Mm M.S. Rods Of Required Sizes To Maintain Proper Level Etc. The Aluminum Framework Is Supported On Side Wall With The Use Of Aluminum L-Section Of Size 1X1 (25X25mm) Angles Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing. , Fabrication And Fixing Of Aluminium Composite Panel Cladding With Thick 3Mm/ 0.25Mm Acp Sheets, Aluminium Framework, With 50 X 25 X1.2 Mm Thick Sections. Silicon Sealants Etc. Including Accessories Complete. , Providing And Laying Laterite Flooring 160Mm Thick With Hard Laterite Stone As Shown In The Drawings, Layed Over Bed Earth, Filling The Joints With Grass, Including As Approved By The Engineer, Etc Complete.Crushing Strength Of Patradevi/Hard Laterite Stone Not Less Than 70Kg/Sqcm , Providing And Fixing Statues (Lion Statue 3D View) Made Up Of Pop Of Size 3.45Ft X 4Ft Including All Fitting Fixtures , Finish Should Be Similar To The Photo Features References,Concepts Of Historic Eras Including All Tools, Plants, Labour And Materials, Leads, Lifts Etc Complete. As Directed By Engineer-In-Charge. , Fabricating, Providing & Fixing Signages Using 304 Grade Stainless Steel 1.5Mm Thick Brushed Steel Finish Plate With Eched Lettering . Ss Plate Of Required Size As Shown In Drawing Will Be Fixed To The Wall/ Door/Wooden Partition With Ss Studs, Complete. Refer Drawing Scspl/Diet/Sign , Supply And Installation Of Dustbin Of Size 15 Dia.And 30Ht. Ndc Or Equivalent,Brown Wood Slated Finish With Pastel Blue Green Lids (Refer Image) Made Up Of Frp Consisting Of Binani Matt Fibres With Gp Resin And Hardener Having A Minimum Of 600 Gsm For Small Size Products Upto 2400 Gsm For Large Size Products For Stability And Durability.Dustbin Must Be Paint By Duco Nc Base Paint Of Choice As Per Ral Code/Duco Catalogue For Good Quality Surface Finish.The Surface Of Dustbin Must Be Smooth Matt Finish. All Tools, Plants, Labour And Materials, Leads, Lifts, Etc Complete. As Directed By Engineer-In-Charge. , Providing And Fixing Of Cast Iron & Frp Benches Made Up Of Cast Iron Powder Coated Frames And Frp Strips Connected To The Frames With Gi Nut Bolt And Gi Clamps Etc. Complete Fitting Length 5 Feet Standard In Size. All Tools Plants, Machinery, Lifts, Transportation Complete. , Supply, Installation,Testing And Commissioning Of 50 Mm X 40 Mm Horizontal Openwell Submersible Pump Having Cast Iron Casing With Cast Iron Impeller, Aisi 410 Shaft. Pump With 5 Hp 2880 Rpm 415 Volts, 50 Hz Ac 3 Phase Electric Motor. Capacity: 270 / 220 Lpm @ 32 / 36 Mtr. Total Head And Digital Control Panel With Float Switch For 2 X 5 Hp Submersible Pumpsets Comprising Of Under Volts / Over Volts Protection, Reversal Phase Protection,Dry Running Protection. , Providing, Installing And Commmissioning Of Aquaguard Eureka Forbes Or Equivalent, Commericial & Industrial Water Treatment Plants Skid Mounted Type Ro Plant Of 500 Litres/Hr Capacity. The Plant Shall House Pressure Sand Filter (Psf) And Activated Carbon Filter (Acf) With The Capacity Providing Fixing 1300 Lph, Reverse Osmosis System With Capacity Of 250Lph, Antiscalant Dosing Sysytem, Micron Cartridge Filter, High Pressure Pump With The Capacity Of 1300 Lph, Uv System And Other Required Accessories Excluding The Cost Of Raw And Clear Storage Tank. All Plants, Equipments, Tools, Machinery, Leads, Lifts Complete. , Providing, Installing And Commissioning Of Water Cooler Of Bluestar Make Or Equivalent With Partial Stainless Steel Material Of 80 Litre Capacity. All Plants, Equipments, Tools, Machinery, Leads, Lifts Complete. , Preparation And Surface Treatment Of Formation. (Preparation And Surface Treatment Of Formation By Removing Mud And Slurry, Watering To The Extent Needed To Maintain The Desired Moisture Content, Trimming To The Required Line, Grade, Profile And Rolling With 8-10 Tonne Smooth Wheeled Roller, Complete As Per Clause 310.) , Scarifying Existing Bituminous Surface To A Depth Of 50 Mm By Mechanical Means (Scarifying The Existing Bituminous Road Surface To A Depth Of 50 Mm And Disposal Of Scarified Material With In All Lifts And Lead Upto 1000 Metres.) , Bituminous Macadam (Providing And Laying Bituminous Macadam With 100-120 Tph Hot Mix Plant Producing Anaverage Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site, Laid Over A Previously Prepared Surface With Paver Finisher To The Required Grade, Level And Alignment And Rolled As Per Mort& H Specifications, Fifth Edition For Grading I ( 40 Mm Nominal Size ) , Excavation For Roadway In Soil By Mechanical Means Including Cutting And Pushing The Earth To Site Of Embankement Lead 50 Metres), Including Trimming Bottom And Side Slopes In Accordance With Requirements Of Lines, Grades And Cross Sections.As Per Morth Specification 301 , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.(A) Size 30 Cm L X 50 Cm H X 15 Cm T , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. A)Size 900 X 400 X 150 Mm With Steel Reinforcement Not Less Than 7 Kg Per Unit -30 T Capacity , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. B)Size 700 X 500 X 75 Mm With Steel Reinforcemnt Not Less Than 3.0 Kgs Per Unit , Supplying And Stacking Laterite Stones Of Size 150-200 Mm(Contractors Stone) For Soling At Site , Laying Stone Soiling Including Packing With Smaller Stones And Consolidation With Road Roller Including Spreading, Watering And Consolidating Of Binding Material Murrum Or Earth Etc.(Payment To Be Made For Quantity Of Only Soling Stone Used Excluding Binding Material) , Providing And Applying Tack Coat With Bitumen Grade Of 80/100 Or Bitumen Emulsion Using Pressure Distributor On The Prepared Bituminous/Granular Surface Cleaned With Mechanical Broom As Per Mort&H Specifications Clause 503. , Providing And Laying Bituminious Concrete With 40-60 Tph Drum Mix Type Hhot Mix Plant Producing An Average Output Of 50 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminious Binder To Mix With Filler, Transporting The Hotmix To Work Site, With All Leads Laying With A Mechanical Paver Finisher To The Required Grade, Level And Alignment, Using Antistripping Agent Rolling With Smooth Wheeled, Vibratory Or Tandem Rollers To Achieve The Desired Compaction Complete As Per Mort& Specifications Clause 509 Grade-Ii (13Mm Nominal Size) @ 6.5% Bitumen Of Grade 60/70 Antistripping Agent @ 0.5% Of Bitumen Content , Providing And Laying 30 Mm Thick Bituminious/Asphaltic Concrete With 40-60 Batch Type Hmp Producing An Average Output Of 50 Tonnes Per Hour Using Crushed Aggregates Of Specified Gradings Premixed With Bituminious Binder At 6.5 % By Weight Of Total Mix And Fillerusing Antistripping Agent Transpoting The Hotmix To Work Site With All Leads And Applying A Tack Coat @F 2.00 Kg/10Sq.M. With Hot Bitumen Of 80/100 And Laying With Mechanical Paver Finisher To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory Or Tandem Rollers To Achieve The Desired Compaction As Per Mort&H Specifications Clause 509 And 503 A) Antistripping Agent @ 0.5% Of Bitumen Content , Providing And Laying Of Hot Applied Thermoplastic Compound 2.5 Mm Thick Including Reflectorising Glass Beads @ 250 Gms Per Sqm Area, Thickness Of 2.5 Mm Isexclusive Of Surface Applied Glass Beads As Per Irc : 35. The Finished Surface To Be Level Uniform And Free From Streaks And Holes As Per Morth Specification 803 , Electrical Works , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panels Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 63A Tpn Mcb As Incommer And 8 Nos 16 A Tpn Mcb As Outgoing With Microcontoller Based Programmable Digital Almac Timer With Voltage Stabilizer, Outdoor Body Should Be Powder Coated. As Shown In Sld. , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. A) 4 Core 10 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.A) 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. A)3 Core 2.5 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 4 X 10 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed /Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 3 X 1.5/2.5 Sq. Mm. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge, Sand Cushioning With Screened Sand Bed Of 20Mm Thick, Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(B) In Rocky Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run (The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(B) In Rocky Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 400 Sq.Mm In The Existing Reinforced Cement Concrete /Hume / Stoneware Metal Pipe, Etc. Complete As Required , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs. D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G) Watering Arrangement(B) In Rocky Strata , Providing And Fixing 6 Swg Dia Gi Wire On Surface Or In Recess For Loop Arthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supply And Erection Of 8 Mtrs Octoganal Pappeared H.D.G.I Pole Made Out Of 4 M.M. Thick Plate And Heavy Provision For Cable Entry, Having Weight Not Less Than 97Kg. 4 Nos Of J Type M24x 750Mm Long Foundation Bolts Of Grade En 8 As Specified By Ged. Along With Suitable Arm And Led Fixture Of Inled Make Specified By Ged Of 80 W , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (A) Sp, Cat A , Laying And Fixing With Collars Light Duty Non-Pressure Np 2 Class Reinforced Cement Concrete Pipes With Cement Mortar In Proportion 1:2 (1 Cement : 2 Fine Sand) In Joints Including Cost Of Jointing Material Etc. Complete.A) 300 Mm Dia Pipe , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Independent Surface/ Recessed Frls Pvc Conduit Of Appropriate Size As Required.(B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Independent Surface/ Recessed Frls Pvc Conduit Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.(C) Group C -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/16 A Modular Switch Connection Painting Etc. As Required.(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 6 Pin 15/16 A And 5/6 A Modular Socket Outlet Modular Socket Outlet And 15/16 A Modular Switch Connection Painting Etc. As Required.A) Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required (A) Cat A , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Supply And Erecting Fan Hook Box (100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supply And Erecting Of 56 Inch (1400 Mm Sweep) Ceiling Fan, Double Ball Bearing Type, Complete With All Accessories. (A) Cat A , Supplying And Erecting Led Surface Lights Of 5 To 8 W, 230V Intergral Type With Required Driver And All The Required Accessories Of Legro, Wipro, Crompton, Bajaj, Havels Make Or Equivalet Approved By Engineer - In - Charge Complete As Required. , Supply, Erection,Testing & Commissioning Of 20 - 24 W Led Tubelight Luminaire.With Required Driver And Other Accessories Of Legro, Wipro, Crompton, Bajaj, Havels Or Equivalent Make Approved By Engineer - In - Charge Complete As Required. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 12 Way Single Door Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supply And Erecting Meter Box Suitable For Three Phase Energy Meter And Incoming Sp/Dp Mcb, Fabricated Out Of 16 Swg Sheet Steel, Powder Coated, Complete As Required And Conforming To The Requirements Of Goa Electricity Deaprtment. , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only.(B) 10 To 40 A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required
Contract Date: Jun 12, 2026 Contract Value : 3.82 Crore
Government Departments No of Bidders 2
18.
Public Administrative Department #10281693 Price Bid
Tender For 13. Development Of Garden In Ambika Colony In Nagar Palika Sheoganj. - 1 Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km). 2 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. 4.10.1 In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar,etc.4.10.1.1 Depth upto 1.5 m. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :1:4:8 (1 Cement : 5 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size) 4 Random rubble masonry with hard stone in foundation and plinth 25.1.1 : Cement mortar 1:4 (1 cement : 4 coarse sand) 5 Brick work with FPS bricks of class designation 75 in foundationand plinth in: 24.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm. 7 Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 32.1.2 1:6 (1 cement : 6 fine/ coarse sand). 8 Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade. 9 Providing and fixing precast cement concrete M-20 grade (Using mechanical Concrete Mixer) kerb stone top and bottom width 115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 10 Providing and fixing of 60mm thick precast cement concreteinterlocking paver block casted with rubber moulds in approvedreflective colour and design having minimum compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mmthick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined.Complete job is to be executed as per the instruction of Engineer in-charge. Therates to be inclusive of all lead & Lifts etc. complete as per specifications. 11 Supplying, erecting and fixing in position specified precast RCC bench made of RCC grade M-30 consisting of 2 Nos. “L” shaped base support of thickness 100 mm back height 1000mm, front height 450 mm, base width 420mm and 5 Nos. RCC planks of size of 1500x100 x 50 mm and 1 Nos RCC planks of 150x200x50mm including joining all parts with galvanised nuts and bolts of suitable size. All bolts to be sealed after assembly with nice finish and appearance and level complete in all respect as per direction of engineer in charge. Every bench should have a manufacture‘s logo of appropriate size Engraved at suitable place. 12 Supply and fixing different type of steel pre-fabricated garden bench/ jhula/ slides and other children play items made of steel duly painted as per approved design and specifications by engineer in charge made of MS pipe, Flates, rectangular hollow section or other steelsections duly welded and or nut bolted where ever required, rubbing and buffing welded joints to make safe for use of children and painted in approved pattern complete as required. 13 Edging with 2nd class bricks, laid dry lengthwise, including excavation, refilling, consolidation, with a hand packing and spreading nearly surplus earth within a lead of 50 metres. 14 Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart. 15 Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead. 2) Earth measured in stacks will be reduced by 20% foe payment. 16 39.11 Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately). 17 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. 39.12.1 In rows 15 cm apart in either direction. 18 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 29.26.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 19 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 32.50.1 Two or more coats on new work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
19.
Housing Urban and Rular Development #10230546 Price Bid
Improvement At Ganapathiyenthal Oorani At Ganapathiyenthal Village In Keelanettur Panchayat-- 1 Improvements of GanapathiyenthalOorani and Bhathing Ghat at Ganapathiyenthal Village inkeelanettur Panchayat 2 Clearing light jungles and clearing away carefully and burning it including all labour charges etc..m 3 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods,sectioning etc., complete (based on standard schedule of rates vid., S.no 86 Item no.1) 4 Construction of Step 5 Earth work excavating and depositing on bank with an initial lead of 10M and initial lift of 2m in hard stiff clay stiff block cotton, hard red earth shales, murrams, gravel, stoneyearth and earth mixed with small size boulders and hard gravelly soil SS 20B for foundation 6 Collection and supply of M.sandand filling in to the basement including cost and conveyanceto the siteand all labour charges for filling 7 Cement concrete 1:4:8 using 40mm HBGS jelly including all incidental charges such as bailing out water finishing curing complete complying with standard specification 8 Providing Centering charges for C.C works including material all labour charges etc.,completed. 9 Reinforced cement concrete 1:1.5:3 mix using 20mmISS metal labour charges for mixing, laying, and curing etc complete for 10 cum labour charges for mixing, laying, and curing etc complete for 10 cum 10 Supplying and fabrication of steel including cost and conveyance of steel to site and all labour charges for straightening, cutting to length, bending to shape and tying in position and forming grills for all R.C.C works 11 Cement concrete 1:3:6 using 40mm HBGS jelly including all incidental charges such as bailing out water finishing curing complete complying with standard specification 12 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
22.
Housing Urban and Rular Development #10104415 Price Bid
Tender For Rejuvenation Of Agamt Oorani ( Desilting Of Pond ( 50M X 50M ) & Construction Of Retaining Wall 33.50M ) At N.Muthusamypuram Panchayat Of Sattur Blockin Virudhunagar District Under Agamt Ii 2023-2024. 1 Rejuvenation Of Oorani 2 Earth Work In All Soils Except Hard Rock Requiring Blasting And Conveying For Formation Of Bund With Lead Of 0 To 100 Metre Deploying Earth Moving Machinery And Tippers Including Benching, Formation Of Bunds, Breaking Clods, Sectioning Etc., Complete 3 Earth Work Excavating And Depositing On Bank With Initial Lead Of 10 M & Initial Lift Of 2M In Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Murram, Gravel, Stoney Earth And Earth Mixed With Small Size Boulders Ss.20 4 Cement Concrete 1:4:8 Mix Using 40Mm Iss Metal Including Cost And Conveyance Of All Materials To Site And All Labour Charges For Mixing, Laying And Curing Etc Complete 5 Centering Charges For All Concerete Works Including All Labour Charges Etc., Complete As Per Standared Specification 6 Cement Concrete 1:3:6 Mix Using 40Mm Iss Metal Including Cost And Conveyance Of All Materials To Site And All Labour Charges For Mixing, Laying And Curing Etc Complete 7 Cement Concrete 1:2:4 Mix Using 20Mm Iss Metal Including Cost And Conveyance Of All Materials To Site And All Labour Charges For Mixing, Laying And Curing Etc Complete 8 Gst Amount For Providing Service To Government Contract Works For The Above Construction Works. { Gst Amount Is The Total Gst Amount For Total Overall Quoted Amount Above This Row In Column Bb For All Works In This Package }
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
23.
Tourism #10027930 AOC
Proposed Conservation And Repair Work To Naroshankar Temple, At.Panchvati,Tq.Dist.Nashik - Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.SSR 2022-23 Page No.157 Item No. 21.34 2 Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide Glycel(iso proplamine salt of glyphosate) or other chemical as specified by the Engineer incharge etc. complete.SSR 2022-23 Page No.301 Item No. 46.58 3 Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. SSR 2022-23Page No. 224 Item No. 35.18 4 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR 2022-23Page No. 297 Item No. 46.19 5 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete S.S.R. 2022 - 23 Page No.296,Item No.46.12 6 Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete. SSR 2022-23Page No.296 Item No.46.14 7 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.S.S.R. 2022 - 23 Page No.211,Item No.32.33 8 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etcS.S.R. 2022 - 23 Page No.296,Item No.46.09 9 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete S.S.R. 2022 - 23 Page No.296,Item No.46.15 10 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directedinthe compound including scaffolding etc. complete.S.S.R. 2022 - 23 Page No.235,Item No.38.26 11 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.SSR 2022-23Page No.297 Item No.46.29 12 Removing wooden or A.C.partition including frame work and stack-ing the materials as with all leads, lifts etc. complete.SSR 2022-23Page No.296 Item No.46.17 13 Dismantling flat wooden orA.C. Sheet ceiling with framework including stacking the materials as directed with all leads, lifts etc. complete..SSR 2022-23Page No.296 Item No.46.06 14 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.SSR 2022-23Page No.299 Item No.46.42 15 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.SSR 2022-23Page No.298 Item No.46.38 16 Specialised Stone cleaning to remove oil or emulsion paint,stains or dark patches,layers of impervious coatings,cementious layers,rust stains from surface of stone with chemicals ,thinners,solvents or soft teepol type soap solution or by pressure jet machine (As specified by consulting architect),A gentle use of air abrasive tools may be permitted as long as no damage to the original surface is ensured.it may include usage of mechanical tapping ,chemical surfactant or solvant,patent cleaning product or use of pressurised micro abrasive as necessary.test patches would need to be undertaken to asses efficeincy of technique prior to work.Removal to be followed by water washing.The surface shall finally be cleaned by hand rubbing and rinsing with clean water to obtain nearly original surface,colour and textureNON SSR R.A.34 17 Gently cleaning the surface of stone masonary with specialised water misting technique employing air water jet usinga fine nossle sprinkling system calibrated to sprey fine mist along the stone surface without over wetting followed up by gentle brushing with soft nylon brushesand removing dirt,dist,bird dropping,grease,oil,algae,fungus,monkey beats,vegetable growth,etc as specified.gentle surface cleaning using water misting and mild pH balanced surfactants as specified for indicated areas to remove the surface dirt,grit accretion by means of water misting and cleaning etc.complete as directed by engineer in chargeBMC -USOR-R3-CS-CH-1,2023 18 Removing pointing and other epoxy-based hard material from joints and surface area of Basalt stone masonary manually with chisel and hammer or with the help of electric grinders wherever directed by Engineer In charge. Proper care should be taken not to damage the stone during removal. 19 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc.complete.NON SSR R.A No.203 20 Lowering down carefully existing stone masonry of the monument manually in proper order including shifting the stone elements up to a distance of 50 meter beyond the monument area and stacking them as directed by Engineer in-charge, removing building rubbish and cleaning the site etc. complete .NON SSR R.A No.204 21 Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete Non - S.S.R. Item From Rate Analysis No. 136 of Deapartment Rate Abstract 22 Providing Lime Pointing to brick work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwise specified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sand shall not be ground fine but sand should be finer, the joints of the pointed work shall be neatly defined by the pointing, the lines shall be regular and uniform in breadth and the joints shall be raised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple (Belfruit) per cubic metre of lime mortar as a bonding material, scaffolding, watering and all work when handed over to be perfectly clean and free from all mortar stains etc. complete.Non - S.S.R.Item From Rate Analysis No. 138 of Deapartment Rate Abstract 23 Providing injection grouting with lime and fine screened sand slurry in proporation of (1 : 1) with a proper jet pump pressure including cleaning and washing and packing the existing crack / holes in the brick or stone masnory with lime and finesand paste in proporation of (1:1) properly from down side, filling the slurry in cracks or holes including all necessary actions and required tools and machineries, scaffolding, curing etc. complete. for soil stabilizationNon S.S.R. 24 Excavation for foundation in earth, soils of all types sand, gravel and soft murum,Including removing the excavated matreial upto a distance of 50 M beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling ,ramming, watering Including shoring and strutting etc.complete ( Lift upto 1.50m ) SSR 2022-23Page No.153 Item No. 21.01(By manual Means) 25 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. SSR 2022-23Page No.157 Item No. 21.40 26 Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete.SSR 2022-23Page No.346 Item No. 50.60 27 Providing and laying cast in situ 1:2:4 Lime Concrete of Trap stone metal for foundation and bedding as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer, bailing out water, watering etc. complete.NON SSR R.A. No. 4 28 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete..(NON SSR R.A No.87) 29 Providing Block In Course Masonry of trap / granite stones in lime mortar 1:1½ with size of stone 0.60m. x 0.45m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the face of stones shall be rough-tooled, rustic (with or without chisel draft, except at quoins), or chamfered as specified, the beds and joints of all ashlar stones to be dressed perfectly true, square and full, headers shall not be less in length than breadth of ashlar stone plus 45 cm. (1ꞌ6″), the stones shall be set in mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 17.5 cm. (7″) in height, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.NON SSR 39 30 Providing/Re-setting Stone Paving, Second Sort of reuse-stones in lime mortar 1:1½, per detailed specifications and drawings or as directed including the joints running true, the stones to be laid with joints not exceeding 8 mm. (5/16″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to beperfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.152 31 Providing and fixing Stone Paving, SecondSort in lime 1:1/2 mortar, with average size of stone 0.45 m. x 0.30 m. x 0.15m. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete.flooring for ghat and parking NON SSR R.A. No.151 32 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with size of stone 0.45 m. x 0.30 m. x 0.15 m., as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stones to be laid with joints not exceeding 6 mm. (¼″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.149 33 Providing/Re-setting Ashlar Rough tooled Masonry of reuse-stones in lime mortar 1:1 in superstructure as per detailed specifications and drawings or as directed including the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.16 34 Providing Ashlar Rough Tooled Masonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No15 35 Providing/Re-setting Ashlar Fine Masonry of reuse-stones in lime mortar 1:1 in superstructure as per detailed specifications and drawings or as directed including the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.12 36 Providing Ashlar FineMasonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No11 37 Providing/Re-setting Ashlar Fine Stone Steps of reuse-stones in lime mortar 1:1 as per detailed specifications and drawings or as directed including each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.62 38 Providing Ashlar Fine Stone Steps of trap / granite stones in lime mortar 1:1with size of stone 0.6m. x 0.400 m. x 0.220 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be fine dressed on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.61 39 Providing Ashlar Fine Masonry of trap / granite stones for GAUMUKH in lime mortar 1:1 with average size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 40 Providing Ashlar Fine Masonry of trap / granite stones for TADKHADA(BASESTONE) in lime mortar 1:1 with average size of stone 0.60 m. x 0.60 m. x 0.60 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 41 Providing Ashlar Fine Masonry of trap / granite stones for Columns/Ganesh Patti/Lintel/Chandrashila/Ardha-Chandrashila in lime mortar 1:1 with average size of stone 0.6 m. x 0.6 m. x 2.70 m in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 11 42 Providing Ashlar Fine Masonry of trap / granite stones for Beams/Ganesh Patti/Lintel/Chandrashila/Ardha-Chandrashila in lime mortar 1:1 with average size of stone 0.51 m. x 0.51 m. x 2.70 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 43 Providing Ashlar Fine Masonry of trap / granite stones for CIRCULAR BRACKET in lime mortar 1:1 with average size of stone 0.70m. x 0.70 m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 44 Providing Ashlar Fine Masonry of trap / granite stones for FOURWAY BRACKET/RECTANGULAR BRACKET in lime mortar 1:1 with average size of stone 0.70m. x 0.70 m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 45 Providing Ashlar Fine Masonry of trap / granite stones for KARNSHILA CAP,KARNSHILA STONES in lime mortar 1:1 with average size of stone 1.85m. x 0.90m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 46 Providing Ashlar Fine Masonry of trap / granite stones for SLAB in lime mortar 1:1 with average size of stone 0.6m. x 0.60 m. x 0.508 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 47 Providing Ashlar Fine Masonry of trap / granite stones for CHAJJA STONES in lime mortar 1:1 with average size of stone 0.9m. x 0.60m. x 0.216 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 48 Providing Ashlar Fine Masonry of trap / granite stones for KAKSHASHAN in lime mortar 1:1 with average size of stone1.85m. x 0.90m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 49 Providing Ashlar Fine Masonry of trap / granite stones for Galtha in lime mortar 1:1 with average size of stone 0.70m. x 0.70m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 50 Providing Ashlar Fine Masonry of trap / granite stones for Parapet in lime mortar 1:1 with average size of stone 0.60m. x 0.45m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 51 Providing Ashlar Fine Masonry of trap / granite stones for Shikhar Urshringe block in lime mortar 1:1 with average size of stone 0.40m. x 0.40m. x 0.81 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 52 Providing Ashlar Arching of trap / granite stones in lime mortar 1:1, with size of stone 60 cm. x 45 cm. x 30 cm. as per detailed specifications and drawings or as directed including the arch stones be of approved quality, colour, hard and free from defect of any kind, the arch stones in all cases of the entire thickness, the arch stones shall be dressed full and true to their proper shapes with the necessary summering, twist or winding and be set in fine mortar, the intrados, joints and beds to fair tooled and left full, the cast or keying course to be accurately fitted, at all horizontal joints the intrados to have a 2 cm. (¾″) chamfer, the face stone may be tooled or rock-faced with or without chamfer as directed, in arches up to 60 cm. (2ꞌ) in depth all stones shall be of the full thickness of the ring, arches to be built on proper centring, the bed joints shall be radial and the side joints shall be at right angles to the bed joints and the thickness of the joints shall not exceed 5 mm. (3/16″) preparing the lime mortar in lime miller, cantering/scaffolding, watering and all archwork when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No125 53 Providing Brick Arching Second Class of second class bricks of size 9″ x 4½″ x 2½″ in lime mortar 1:1½ as per detailed specifications and drawings or as directed including the bricks to be of uniform size, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks to be laid in concentric half-brick ring, the joints are to be properly summered and not to exceed 17 mm. (⅔″) in thickness, the joints to be truly radial to the curve at all points, great care to be taken that the rings are bonded together properly,whenever the joints of any of the rings come to a summering or plane face, all arches to be turned on centrings, preparing the lime mortar in lime miller, cantering/scaffolding, watering and all arch work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 133 54 Providing Brick Masonry Second Class in superstructure with size of brick9″ x 4½″ x 2½″ in lime mortar 1:1½, as per detailed specifications and drawings or as directed including the bricks to be of uniform size, moulded ground, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks are to be laid flush in mortar in suchbond as directed, as far as possible, bricks of uniform colour are to be selected for theface work when it is not to be plastered, the joints are not to exceed12.5 mm. (½″), no bats or half brick to be usedin the work, racking out joints where pointing or plastering tobe done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 119 55 Carving ornamental work including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. The charges for chisscling & dressing on stone surface for govering at the stone surface after chisling a fine surface rate for as per market rate. 56 Caving ornamental work on surface including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete.The charges for chiseling & dressing on stone surface for ornamental carving work surface etc. as per existing design. pattern and form as directed by engineer in chargeRates as per R.A. No. 29 57 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.For Lowering Down NONSSR206 58 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.For Restoring NONSSR206 59 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete. NON S.S.R. R.A.6 60 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete SSR 2022 - 23Page No.245 Item No.39.01 61 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete SSR 2022 - 23Page No.246 Item No.39.08 62 Providing and applying melamine polish of required finish to the wood work byspray machine including knotting and preparing the even surface by scraping,applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.SSR 2022 - 23Page No.222 Item No.34.09 63 Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.SSR 2022 - 23Page No.294 Item No.44.10 64 Providing12 mm. thick Rough Cast Lime Plaster and 10 mm thick in doublecoat in lime mortar 1:1/2 and 1:1(22 mm) lime putty fine coat on last layer in plinth, as perdetailedspecificationsanddrawingsorasdirectedincludingalljointsinmasonryandbrick work are to be racked out to a depth of at least 20 mm. and the wall to be washed with fresh water andthoroughlywettedforsixhoursbeforeplastering,theplastertobeappliedinanevenand uniform coat well pressed in to the joints and to be well beaten for 1½ days with hand tappers, the plaster should also be well sprinkle during the proses of beating with a mixture of 1.10 jaggary and 640grampulpofwoodapple(Belfruit)in90to135litreofwater,theplasterbeingwetted occasionally with fresh water while the beating is in progress, all exposed angles and junctions with door frame to be carefully finished, all mouldings shall be worked true to template and drawn neat, clean and level, soffits of arches must true arch of circle, preparing the lime mortar in lime miller with 1.60 kg Gugal (a kind of fragrant gum) and 960 gram chopped hemp (fibre of bhendi or tag ) per cubic metre of lime mortar as a bonding material, of lime as a bonding material, watering and allwork when handed over to be perfectly clean and free from all mortar stains etc. complete.NONSSR RA142 65 Stucco work in lime, surkhi and sand (1:1:1) as per traditional practices and design, the mortar should be prepared by grinding mill only. The thickness varies from 10mm to 100mm as per design.NON SSR 2022 - 23 66 Providing and applying integral fine coat, with addition of colour pigments, as paint to the plainlime stucco plaster in 2 layers, including scaffolding, curing, all leads and lifts, etc. complete. 1) The first coat to be laid is a mixture of fine lime and white washing lime in proportion of 2:1,made smooth with wooden rubbers and very lightly beaten. 2)The finishing coat consisting of fine lime, white washing lime, mixed with the appropriate pigment in 1:2:1 proportion is to be applied and well polished with trowels. .NON SSR 2022 - 23 67 Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in- charge, of approved brand and manufacture, diluted withsolventmineral Turpentineoil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sandstonemasonry surfacewith two or more coats to give uniform application of chemical onthe surface, all completeas per direction of Engineer-In-charge (The rate is inclusive of allmaterials& labours involved except scaffolding).Non - S.S.R. 68 Disposing of dismantling materials of R.C.C./ stone / brick masonry / derbies, excavated material / soil / murum / rubbish material or vegetation / grass / shrubs etc., from work site beyond the 5km. SSR 2023-24STATEMENT C1 PG NO.459 69 Providing and fixing of retro-reflectorised informatory sign board rectangular /Square in shape having area greater than 0.9 square meter made out of 2mm aluminum sheet bonded withwhite retroreflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive / heat activated adhesive retoreflective specified background, border and backside reto reflctive symbols,letters, numerals, arrowasper IRC:67-2012TableNo8.3, supported with back support frame25mmx25mmx3mm,duly painted on back side with two coats of grey stove enamel paint and supported on one Number mild steel angle iron post 75mmx75mmx6mm,3.5mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45cmx45cmx60cm,60cm below ground level asper approveddrawingTheangle ironpost shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paint having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. The nut bolts of board with angle iron post / supportingstructureafter fixingat sitehas tobeelectrically welded.ClassB(TypeIVHighintensitymicro-prismaticgrade sheeting-HIP) sheeting shall have7 yearswrittenwarranty fromthemanufacturerandauthoriseddistributor / convertor issued for field performance including the screen printed areasandcut-out sheetingandcut-out durable transparent overlay film and this warrantySSR 2022 - 23Page No.58 Item No.6.34 70 Providing and fixing Required Size Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete SSR 2022-23Page No.294 Item No.44.12 71 Public Seating Chair. - 3 Seater Providing and Fixing 3seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.SSR 2022-23Page No.359 Item No.51.44 72 Supplying and erecting Solar Street Light Non SSR 73 Preparing and carrying out videography, Documentary & Shooting of still photographs of Extra copies - 5 X 7 Sizeoutdoor and indoor of roads, bridges, other structures and programme, including preliminarys survey, still shots moving shooting, necessary board for video shooting hiring of vehicle, equipment for video shoot­ing, transportation of all equipment, persons, required for shooting, lighting arrangement as may be necessary, editing, mixing, titling, lettering, sounding including cost of coloured cassette of approved quality etc. completeNON SSR 74 Book Designing, Publishing and Printing: The work involves printing of a book / guidebook on the fort / monuments and its various aspects, which would provide authentic and precise tourism oriented information. This work involves important photographsof the site, art objects, antiquities, inscriptions etc., which would be useful for educating the masses of the rich cultural heritage of the site, region and state. providing 100 pages coloured books as directed by engineer in charge / ADA Non SSR 75 Preparation of Photogrammetric and LiDAR Survey Plan of the Monuments/Sites to delineate Protected & Controlled Areas. Scope Photogrammetry, LiDAR, UAV/drone-based surveying, geo-tagging monuments. Non SSR 76 Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line , encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New AlignmentSSR 2022-23 Page No.17 Item No. 1.41
Contract Date: Apr 20, 2026 Contract Value : 2.89 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
24.
Tourism #10023424 AOC
Proposed Conservation And Repair Work To Kot Wall In Precinct From Ekmukhi Datta Mandir To Balaji Kot, At.Panchvati, Tq.Dist.Nashik- 1 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.SSR 2022-23Page No.299 Item No.46.42 2 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.SSR 2022-23Page No.298 Item No.46.38 3 G.I sheet (Patra) Partition: As per Instruction erect the vertical poles at a distance of 8 to 10 feet & on that provide the horizontal poles & prepare the square, on that fix the GI sheet (patra) .Provide the opening in patra where required. Instructions:- 1) In this work Excavation in any type of road, soil, loose or hard rock should be done and after the work Excavated pits should be refill. 2) The rate of the above work is for 3 days and because of if any reason days exceed beyond 3 days Rate as perfollowing will be given a) for 4th day to 30 th day- 3% of original rate.PMC(BHAVAN)DSR 2022-23, Item No.2998,AG 65.14 4 Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) SSR 2022-23Page No.85 Item No. 12.22 5 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.SSR 2022-23 Page No.157 Item No. 21.34 6 Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide Glycel(iso proplamine salt of glyphosate) or other chemical as specified by the Engineer incharge etc. complete.SSR 2022-23 Page No.301 Item No. 46.58 7 Specialised Stone cleaning to remove oil or emulsion paint,stains or dark patches,layers of impervious coatings,cementious layers,rust stains from surface of stone with chemicals ,thinners,solvents or soft teepol type soap solution or by pressure jet machine (As specified by consulting architect),A gentle use of air abrasive tools may be permitted as long as no damage to the original surface is ensured.it may include usage of mechanical tapping ,chemical surfactant or solvant,patent cleaning product or use of pressurised micro abrasive as necessary.test patches would need to be undertaken to asses efficeincy of technique prior to work.Removal to be followed by water washing.The surface shall finally be cleaned by hand rubbing and rinsing with clean water to obtain nearly original surface,colour and textureNON SSR R.A.34 8 Gently cleaning the surface of stone masonary with specialised water misting technique employing air water jet usinga fine nossle sprinkling system calibrated to sprey fine mist along the stone surface without over wetting followed up by gentle brushing with soft nylon brushesand removing dirt,dist,bird dropping,grease,oil,algae,fungus,monkey beats,vegetable growth,etc as specified.gentle surface cleaning using water misting and mild pH balanced surfactants as specified for indicated areas to remove the surface dirt,grit accretion by means of water misting and cleaning etc.complete as directed by engineer in chargeBMC -USOR-R3-CS-CH-1,2023 9 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR 2022-23Page No. 297 Item No. 46.19 10 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directedinthe compound including scaffolding etc. complete.S.S.R. 2022 - 23 Page No.235,Item No.38.26 11 Removing wooden or A.C.partition including frame work and stack-ing the materials as with all leads, lifts etc. complete.SSR 2022-23Page No.296 Item No.46.17 12 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete S.S.R. 2022 - 23 Page No.296,Item No.46.12 13 Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete.SSR 2022-23Page No.296 Item No.46.14 14 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.S.S.R. 2022 - 23 Page No.211,Item No.32.33 15 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc S.S.R. 2022 - 23 Page No.296,Item No.46.09 16 Removing pointing and other epoxy-based hard material from joints and surface area of Basalt stone masonary manually with chisel and hammer or with the help of electric grinders wherever directed by Engineer In charge. Proper care should be taken not to damage the stone during removal. 17 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc SSR 2022-23Page No.296 Item No.46.11 18 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.SSR 2022-23Page No.297 Item No.46.29 19 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc.complete.NON SSR R.A No.203 20 Lowering down carefully existing stone masonry of the monument manually in proper order including shifting the stone elements up to a distance of 50 meter beyond the monument area and stacking them as directed by Engineer in-charge, removing building rubbish and cleaning the site etc. complete .NON SSR R.A No.204 21 Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete Non - S.S.R. Item From Rate Analysis No. 136 of Deapartment Rate Abstract 22 Providing injectiongrouting with aslurryof lime and fine screened sand in proporation of (1 : 1) with a proper jet pump pressure including cleaning and washing and packing the existing crack / holes in the brick or stone masnoryproperly upward with slurry,scaffolding,curing etc. complete and machineries, scaffolding, curing etc. complete.Non S.S.R. 23 Excavation for foundation in earth, soils of all types sand, gravel and soft murum,Including removing the excavated matreial upto a distance of 50 M beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling ,ramming, watering Including shoring and strutting etc.complete ( Lift upto 1.50m ) SSR 2022-23Page No.153 Item No. 21.01 24 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. SSR 2022-23Page No.157 Item No. 21.40 25 Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete.SSR 2022-23Page No.346 Item No. 50.60 26 Providing and laying cast in situ 1:2:4 Lime Concrete of Trap stone metal for foundation and bedding as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer, bailing out water, watering etc. complete.NON SSR R.A. No. 4 27 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete..(NON SSR R.A No.87) 28 Providing and fixing Stone Paving, SecondSort in lime 1:1/2 mortar, with average size of stone 0.45 m. x 0.60 m. x 0.15m. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete.flooring for ghat and parking NON SSR R.A. No.151 29 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with size of stone 0.45 m. x 0.60 m. x 0.15 m., as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stones to be laid with joints not exceeding 6 mm. (¼″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.149 30 Providing Ashlar Rough Tooled Masonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No15 31 Providing Brick Masonry Second Class in superstructure with size of brick9″ x 4½″ x 2½″ in lime mortar 1:1½, as per detailed specifications and drawings or as directed including the bricks to be of uniform size, moulded ground, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks are to be laid flush in mortar in suchbond as directed, as far as possible, bricks of uniform colour are to be selected for the face work when it is not to be plastered, the joints are not to exceed12.5 mm. (½″), no bats or half brick to be usedin the work, racking out joints where pointing or plastering tobe done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 119 32 Providing Ashlar Arching of trap / granite stones in lime mortar 1:1, with size of stone 60 cm. x 45 cm. x 30 cm. as per detailed specifications and drawings or as directed including the arch stones be of approved quality, colour, hard and free from defect of any kind, the arch stones in all cases of the entire thickness, the arch stones shall be dressed full and true to their proper shapes with the necessary summering, twist or winding and be set in fine mortar, the intrados, joints and beds to fair tooled and left full, the cast or keying course to be accurately fitted, at all horizontal joints the intrados to have a 2 cm. (¾″) chamfer, the face stone may be tooled or rock-faced with or without chamfer as directed, in arches up to 60 cm. (2ꞌ) in depth all stones shall be of the full thickness of the ring, arches to be built on proper centring, the bed joints shall be radial and the side joints shall be at right angles to the bed joints and the thickness of the joints shall not exceed 5 mm. (3/16″) preparing the lime mortar in lime miller, cantering/scaffolding, watering and all archwork when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No125 33 Providing/Re-setting Ashlar Fine Stone Steps of reuse-stones in lime mortar 1:1 as per detailed specifications and drawings or as directed including each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.62 34 Providing Ashlar Fine Stone Steps of trap / granite stones in lime mortar 1:1with size of stone 0.6m. x 0.400 m. x 0.220 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be fine dressed on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.61 35 Providing Semi-circular Coping Cut-stone Second Sort, 22.5 cm. (9″) height and 52.5 cm. (1ꞌ9″) wide of trap / granite stones in lime mortar 1:1½ with size of stone0.60 m. x 0.60m. x 0.200 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stone shall be dressed full or to template, exposed face of the stones shall be fine rough tooled, semi-circular and all joints shall be in line and close and not more than 3 mm. (⅛″) thick, preparing the lime mortar in lime miller, scaffolding, watering and all coping work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 59 36 Providing and fixing 50mm diameter and 1.5 mm thick vertical and top Stainless steel hand railing in S.S.304 Grade with Stainless steel square / circular pipe bracing of size 32mm x32mm x1.5 mm in 3 rows including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete SSR 2022-23Page No.379 Item No. 51.111 37 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.NONSSR206 38 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete. NON S.S.R. R.A.6 39 Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical: 12 Part of Turpentine oil), on the existing Basalt stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 40 Providing12 mm. thick Rough Cast Lime Plaster and 10 mm thick in doublecoat in lime mortar 1:1/2in plinth, as perdetailedspecificationsanddrawingsorasdirectedincludingalljointsinmasonryandbrick work are to be racked out to a depth of at least 20 mm. and the wall to be washed with fresh water andthoroughlywettedforsixhoursbeforeplastering,theplastertobeappliedinanevenand uniform coat well pressed in to the joints and to be well beaten for 1½ days with hand tappers, the plaster should also be well sprinkle during the proses of beating with a mixture of 1.10 jaggary and 640grampulpofwoodapple(Belfruit)in90to135litreofwater,theplasterbeingwetted occasionally with fresh water while the beating is in progress, all exposed angles and junctions with door frame to be carefully finished, all mouldings shall be worked true to template and drawn neat, clean and level, soffits of arches must true arch of circle, preparing the lime mortar in lime miller with 1.60 kg Gugal (a kind of fragrant gum) and 960 gram chopped hemp (fibre of bhendi or tag ) per cubic metre of lime mortar as a bonding material, of lime as a bonding material, watering and allwork when handed over to be perfectly clean and free from all mortar stains etc. complete.NONSSR RA142 41 Stucco work in lime, surkhi and sand (1:1:1) as per traditional practices and design, the mortar should be prepared by grinding mill only. The thickness varies from 10mm to 100mm as per design.NON SSR 2022 - 23 42 Providing and applying integral fine coat, with addition of colour pigments, as paint to the plainlime stucco plaster in 2 layers, including scaffolding, curing, all leads and lifts, etc. complete. 1) The first coat to be laid is a mixture of fine lime and white washing lime in proportion of 2:1,made smooth with wooden rubbers and very lightly beaten. 2)The finishing coat consisting of fine lime, white washing lime, mixed with the appropriate pigment in 1:2:1 proportion is to be applied and well polished with trowels. .NON SSR 2022 - 23 43 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailingout water, Steel centering formwork, laying/pumping cover blocks, compaction andcuring roughening the surface if special finish is to be provided (Excluding reinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade)SSR 2022 - 23Page No.178 Item No.25.11 44 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap /granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing oras directed including steel centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness togive a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)SSR 2022 - 23Page No.179 Item No.25.31 45 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, complete.SSR-2022-23 Item.No.26.33 Pg. No.188 46 Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.SSR 2022 - 23Page No.294 Item No.44.10 47 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. SSR 2022-23Item No. 32.12,Page No.209 48 Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge). S.S.R. 2022 - 23 Page No. 409,Item No.51.192 49 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete SSR 2022 - 23Page No.245 Item No.39.01 50 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete SSR 2022 - 23Page No.246 Item No.39.08 51 Providing and applying melamine polish of required finish to the wood work byspray machine including knotting and preparing the even surface by scraping,applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.SSR 2022 - 23Page No.222 Item No.34.09 52 Disposing of dismantling materials of R.C.C./ stone / brick masonry / derbies, excavated material / soil / murum / rubbish material or vegetation / grass / shrubs etc., from work site beyond the 5km. SSR 2023-24STATEMENT C1 PG NO.459 53 Public Seating Chair. - 3 Seater Providing and Fixing 3seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.SSR 2022-23Page No.359 Item No.51.44 54 Preparing and carrying out videography, Documentary & Shooting of still photographs of Extra copies - 5 X 7 Sizeoutdoor and indoor of roads, bridges, other structures and programme, including preliminarys survey, still shots moving shooting, necessary board for video shooting hiring of vehicle, equipment for video shoot­ing, transportation of all equipment, persons, required for shooting, lighting arrangement as may be necessary, editing, mixing, titling, lettering, sounding including cost of coloured cassette of approved quality etc. completeNON SSR 55 Book Designing, Publishing and Printing: The work involves printing of a book / guidebook on the fort / monuments and its various aspects, which would provide authentic and precise tourism oriented information. This work involves important photographsof the site, art objects, antiquities, inscriptions etc., which would be useful for educating the masses of the rich cultural heritage of the site, region and state. providing 100 pages coloured books as directed by engineer in charge / ADA Non SSR 56 Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line , encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New Alignment SSR 2022-23Page No.17 Item No.1.41 57 Providing and fixing of retro-reflectorised informatory sign board rectangular /Square in shape having area greater than 0.9 square meter made out of 2mm aluminum sheet bonded withwhite retroreflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive / heat activated adhesive retoreflective specified background, border and backside reto reflctive symbols,letters, numerals, arrowasper IRC:67-2012TableNo8.3, supported with back support frame25mmx25mmx3mm,duly painted on back side with two coats of grey stove enamel paint and supported on one Number mild steel angle iron post 75mmx75mmx6mm,3.5mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45cmx45cmx60cm,60cm below ground level asper approveddrawingTheangle ironpost shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paint having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. The nut bolts of board with angle iron post / supportingstructureafter fixingat sitehas tobeelectrically welded.ClassB(TypeIVHighintensitymicro-prismaticgrade sheeting-HIP) sheeting shall have7 yearswrittenwarranty fromthemanufacturerandauthoriseddistributor / convertor issued for field performance including the screen printed areasandcut-out sheetingandcut-out durable transparent overlay film and this warrantySSR 2022 - 23Page No.58 Item No.6.34
Contract Date: Apr 20, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
25.
Defence #9980227 AOC
Bids Are Invited For Goods Transport Service – Per Km Based Service - Machinery Equipment, Vehicles, Heavyweight/Over Dimensional Cargo, Valuable Goods Requiring High Security, Construction Material; Open Body Lcv Truck; 17 Ft Lcv , Goods Transport Service – Per Km Based Service - Machinery Equipment, Vehicles, Heavyweight/Over Dimensional Cargo, Valuable Goods Requiring High Security, Construction Material; Open Body Taurus; 16 Ft Truck , Goods Transport Service – Per Km Based Service - Machinery Equipment, Vehicles, Heavyweight/Over Dimensional Cargo, Valuable Goods Requiring High Security, Construction Material; Open Body Taurus; 21 Ft Truck , Goods Transport Service – Per Trip Based Service - Heavyweight/Over Dimensional Cargo, Machinery Equipment, Construction Material, Vehicles; Flatbed Truck; 40 To 80 Ft Double Excel , Goods Transport Service – Per Km Based Service - Construction Material, Vehicles, Machinery Equipment; Flatbed Truck; 40 To 80 Ft Double Excel , Goods Transport Service – Per Trip Based Service - Construction Material, Vehicles, Machinery Equipment, Heavyweight/Over Dimensional Cargo, Tk T-72, Tk T-90, Arv Mbt Arjun; Low Bed 60 Ton Truck With Trailer; 10 Ft And Above , Goods Transport Service – Per Km Based Service - Vehicles, Construction Material, Machinery Equipment, Heavyweight/Over Dimensional Cargo, T-72, T-90, Arv Mbt Arjun; Low Bed; 60 Ton Truck With Tlr , Goods Transport Service – Per Trip Based Service - Construction Material; Tipper/Dump Truck; Medium Tipper , Goods Transport Service – Per Trip Based Service - Construction Material; Jcb / Dozer; Tracked And Wheeled Machine For Hy Earth Moving (20 / 21 Ton) , Goods Transport Service – Per Trip Based Service - Construction Material; 20 Ton Crane Hy Duty; 20 Ton Capacity
Contract Date: Ref. Documents Contract Value : 65.86 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 4.15 Lakh
Boards / Undertakings / PSU No of Bidders 6
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 13,520
Statutory Bodies & Commissions/Committees No of Bidders 3
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 27,120
Statutory Bodies & Commissions/Committees No of Bidders 3
Madhya Pradesh View Result →
29.
Drinking Water Supply and Sanitation #9914759 AOC
Tender For Front Entrance Beautification Of Mgr Market In Hosur City Municipal Corporation- 1 Cutting road portion 300mm width and 150mm depth and depositing in bank with initial lead of 10 m & initial lift of 2m . 2 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete 3 Plain Cement Concrete 1:4:8 (one cement, four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification 4 Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 5 Suppling and layingand compacting Wet mix 6 Manufacturing, supplying and fixing in position plain cement concrete precast kerb slab of size 300mm x 600mm x 100mm in Cement Concrete 1:1.5:3 (One cement, Two M - sand and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of slab etc., complete complying with standard specification and as directed 7 Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of63mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, sand cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. 8 Supply and fixing of 1 Metre Length 100mm dia Road Bollard pipe SS 304 withSS Chain @ 2.00mc/c averagewith two rows chain.
Contract Date: Mar 30, 2026 Contract Value : 3.87 Lakh
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 1.43 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 52.12 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 6.00 Lakh
Government Departments No of Bidders 1
33.
Defence #9857154 Technical Bid
Tender For Provision Of Or Md Accommodation At Clement Town Dehradun.; 2 Construction ofORs Md Accn (G+6 storey),(RCC Framed Structure) ,including RCC over head tank of capacity 25KLoverterrace, with permanent specification all as shown on drawings and as specified. 3 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder 4 SCHEDULE A PART II-B (Internal Water Supply) 5 S&F Brass Chromium Plated Wall Mixerfor mixing hot and cold waterwith L bend including shower of size 125 mm and shower arm , screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 6 S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 7 S&F Brass Chromium Plated Angle Valve, fancy typescrewed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 8 S&F Health faucet with hose & hook ( complete set) fixed to angle / stop cock 15 mm dia complete all specified and directed. 9 S&F 15 mm bore CP pillar tap fancy type screwed down for iron pipe complete all specified and directed. 10 S&F 15 mm bore brass chromium platedsink mixer fancy type with swinging spout (wall mounted type) for mixing hot and cold water screwed downfor iron pipe complete all as specifed and directed 11 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder 12 SCHEDULE A PART III-B (Internal Electrification) 13 M & L forpoint wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modularswitch / socketsincl cover plate with frameincluding one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly inclcutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - 14 Note: (i) Also includes inverter wiringwith one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate. 15 (a) One light point/ bulb/ security light /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch. 16 (b) One three pin 5 Amp socket on same board with other switches. 17 (c) One three pin 5 Amp socket on independent board 18 (d) All as per item No 5.01 above but for two way wiring 19 (e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm. 20 All as per item No- 5.01 above but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm. 21 Supply & fixing decorative wall mounted LED tube light 1 x 20 watt with polycarbonate housing and integrated electronic driver with all acessories and fixing materialcomplete all as specified and directed. 22 Supply & fix decorativeLED tube light 1 x 10 watt wall mounted with extruded polycarbonate, integrated lamp & driver with opel diffuser and decorative end plates complete with all acessories and fixing materialcomplete all as specified and directed. 23 Supply & fix LED lamp 9 watt with suitable for batten / angular holder complete all as specified and directed. 24 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 08 way, with 200Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB 160 Amps Capacity and 24 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. Note : MCCB and MCBs shall be provided inside the verticle DBs alongwith suitable size of copper wiring. 25 Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep,min air delivery 210 CFMfive star rated with BLDC motor, super energy efficient, including provision of flexible cable 3 core of suitable size from ceiling rose to fancomplete all as specified and directed. 26 Supply and fixinglight duty Exhaust fan 300 mm sweep metal body with sturdy steel bird cage,double ball bearing and heavy duty motor copper winding, metal blades and fixing accessories 230 Volt, 28 Watt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 27 Supply and fixing light duty Exhaust fan 230 mm sweepmade of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, Rpm 1200, copper windingand fixing accessories 230 Volt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 28 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder 29 SCHEDULE A PART V (Road, Path and Hardatanding) for details refer pdf folder 30 SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder 31 SCHEDULE A PART VI B (Sewage Disposal) 32 M & L for construction of septic tank 100 users withclass B brick masonry wall, PCC in foundation floor, M 30 Design Mix RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7as directed. 33 M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M effective depthall as specified and shown in drawing TD-309, sheet No 1/4 to 4/4 34 SCHEDULE A PART VII (Area Drainage) for details refer pdf folder 35 SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder 36 SCHEDULE A PART IX A(Rain Water Harvesting) for details refer pdf folder 37 SCHEDULE A PART IX B (Rain Water Harvesting) 38 Supply andfilling of sand of size 1.50 mm to 2.00 mm in rain water harvesting pit complete all as specified & directed. 39 Supply andfilling of pea gravel of size 5.0 mm to 10.0 mm in rain water harvesting pit complete all as specified & directed. 40 Supply andfilling of stone grit of size 40.0 mm in rain water harvesting pit complete all as specified & directed. 41 Supply andfilling of brick ballast (half burnt ) in rain water harvesting pit complete all as specified & directed. 42 Boring for rain water harvesting 150 mm diameter boring from level to first water tablecomplete all as specified & directed. 43 SCHEDULE A PART X A (External Water Supply) for details refer pdf folder 44 SCHEDULE A PART X B (External Water Supply) 45 M&Lfor Ductile iron pipe, centrifugally cast spun with socket and spigot ends, class K7 suitable for push on joint (rubber gasket D-jointing), 100mm dia, conforming to IS-8329 (2000), in standard length with cement mortar lining inside the pipe without side zinc coating, laid in trenches complete all as specified and as directed. 46 M&L for road cutting 0.75m width and 1.2m depth for laying and dismantling of DI/GI pipes and making good the disturbed surfaces including returning fillingwith and including and PCC (1:3:6) upto depth 20cm from road surface and removing of soil upto 50m complete all as specified and directed . 47 M&L for construction of masonry Pit of size 750 mm x 750 mm x 750 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 48 M&L for construction of masonry Pit of size 900 mm x 900 mm x 900 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 49 Supply and fixing Air realese valve cast iron,double rubber ball type,body fabricated with cast iron,including high & low pressure cover,cowl as per IS 210 FG 200 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed for size 100mm bore of pipe line complete all as specified and directed. 50 SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 51 SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY) 52 Supplying, installing, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 160 KVA, copper wound, Energy Efficiency Level-III type, with offload changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5 % including suitable cable entry boxes on LT side and HT Bushing on primary side complete in all respects with standard accessories and fitments confirming to IS-1180 (Part-I & II):2014 as specified and as directed including the following- 53 (a) Earthing terminal and rating diagram plate(b) Air release device(c) Oil filling inlet pipe with plug(d) Drain outlet pipe with brass gate valve with dummy plug(e) Conservator with level gauge(f) Silica gel with breather(g) First oil fill up to the recommended level by the manufacturer with new oil confirming to IS 335(h) Type of connection - Delta/Star(j) Type cooling- ONAN(k) Vector group - DYN 11 54 (l) Type of connecting arrangement - ACSR conductor connection on HT Side and cable connection box on LT Side(m) Provision of thermometer with pocket(n)(o) Oil and winding alarm and trip relay including marshal box(p) Platform of Size 3.0x 3.0 x 1.2m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc. and deemed included unit rate quoted by contractor against this item of transformer. 55 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole Number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 56 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 57 M & L including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors and an advances micro controller suitable for outdoor use having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, High voltage trip and auto reset having specification 415 Volts, 50 Hz, 04 Nos incomer MCBs of suitable ratign with auto and manual arrangement including 03 Nos contactor and suitable rating outgoing MCBs single pole type complete with all connected accessories of rating 12 KW 3 phase, current range 40 Amps all as specified. Make- KAKTIYA ENERGY SYSTEM Model No- SWADEEP-02EC12KWP3P or eqvt 58 Material and Labour for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1200X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, 59 with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically grade copper shrouded bus bar of capacity 400 Amps for each phase and 400 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. 60 Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work-INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set. 61 (iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three).(vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. 62 Outgoing:Outgoing with one compartment each comparment will consist the following :(i) MCCB 160 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 01 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos 63 Supply and fixing polycarbonate kiosks box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one NoMCB 16 Amps, SP having size 300X200X150 mm complete including making fixing arrangement on 9 mtr long swaged pole with flat iron clamp including connection from light fitting to junction box with 1.0 sq mm, 3 core wire all as specified and directed by Engr-in-charge. 64 Supply fabricated and fixing street light bracket made out of GI pipe 1.2 mtr long 40/50mm dia medium grade bent to shape including clamps made out of 40 x60 mm flat iron for steel tabular pole, nuts, bolts including painting all as specified 65 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid. 66 SCHEDULE A PART XII A (LIFTS)for details refer pdf folder 67 SCHEDULE A PART XII B (LIFTS) 68 Design, supply, install, testing & commissioning of lift carry 8 passengers , cap 554 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door)including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 69 Design, supply, install, testing & commissioning of lift carry 13 passengers , cap 884 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 70 Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core. 71 Providing manpower & operation of 4 x pessenger lifts at Clement town military station by providing manpower 01 x Un-skilled lift operator per shift in a day for 8 hrs including Sunday & holiday and carrying out minor regular / periodical repairs and regular servicing for upkeep the passenger lift serviceable in all respect, checking of oil levels, thorough checking of lift, make the machinery /equipment dust free, including thorough cleaning up of battery terminals of ARD unit, greasing/oiling of moving parts, leak testing etc all as specified and directed by the Engineer-in-charge. (Note:- (i)The duration of work will be carried out in three shifts from 0600 hrs to 1400 hrs (First Shift), 1400 hrs to 2200 hrs 72 (Second Shift) and 2200 hrs to 0600 hrs ( Third Shift). (ii)The duration of work will be carried out in three shifts of 08 hrs of each shift by deploying the manpower 02 x Un-skilled lift operator in each shift (Total 06 operators in one day) to operate the 04 Nos automatic lift ( 02 x 08 passengers & 02 x 13 Passenger) in high rise towers of G+6 storey). [24 months for DLP & 36 Months after DLP] 73 Comprehensive maintenance of all mechnical & electrical components & conduct a thorough inspection of the fully automatic 04 x passenger lifts ( 02 x 08 passengers & 02 x 13 Passenger) in two high rise tower of G+6 storey) with mechnical & electrical systems, including motor, cables, brakes, control panels & wiring. Identify any signs of wear, drainage or carring out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair / maintenance of unserviceable parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door sills, 74 door locks, control cards and its contacts, hall push buttons and its spares, connector / links, welding of crack/broken and MS parts,kanding operating panel of any size & capacity, repair / maint of u/s damaged door safety edge & sensor mechnical safety locks, megnatic lock of contact, car position indicator & all connected accessories, necessary wiring of hall push button assembly, repair/ mantenance of broken COP/LOP buttons & 75 display including cover, fire alarm, firemen button glass, intercom, alarm/hooters, maintenance of damged hand rail shaft, light / switches , complete with illuminated push button & direction indicator with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors & safe operation of lifts, fixing of loose rail brackets if any, cabin mirror light & minor repair of cabin fan, ensure safe & smooth functioning of lift & complete maintenance of car top, binding of loose wire at control panel & rust painting at car top and door, dewatering of lift well in case of any emergency arise all as directed by Engineer-in-charge. [ 36 Months after DLP] 76 SCHEDULE A PART XIII A (DG SETS)for details refer pdf folder 77 SCHEDULE A PART XIII (DG SETS) 78 Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CPC B-IV approved ),static type Diesel Engine driven,Generating set of 40 KVAcapacity confirming to BS-5514/IS -13018:1990(Engine) & IS-13364/IS-4722 (Alternator), 4 wire 50 HZ415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . 79 The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. 80 (A) Alternator:- Alternator shall be of capacity of 40 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .85,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-13364/IS-4722 complete all as specified . 81 ( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work siteand as per relevant IS code having provision of coupling shaft to drive the above Alternator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):- 82 (i) Fly wheel with housing .(ii) Air cleaner dry type(iii) Corrosion resisiters.(iv) fuel filter, Oil filter (v) FIP system including pump injectors solenoid controls , nozzles, govenors etc(vi) Radiiator including water pump with fan (vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside theDG Set building. 83 (a) Lead acid battery 12 volts , 90/100AH = 01Nos. initially chargedMake :- Exide/Prestolite/ AMCO ( Maintenance free type)(b) Self Starter.(c)Alternator12 volts DC complete with holding clamp. (d) Start / Stop push button ,ignition switch with key system.(e) Battery charging system including regulator and generator / alternator 84 (viii) Engine shallbe with turbo charger.(ix) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.(x) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc. 85 (C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable of 40 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minralrock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- 86 (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section .(ii) Structure heavy duty rectangular MS box channel .(iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks .(iv) Out side cover: Made out of CRCA sheet 2 mm thick.(v)Accustic insulation ( side &Top )sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material .(vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated .(vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel . 87 (D)AMF CONTROL PANEL:- As per manufacturers design with the following equipments. (a) 2 Nos. , 3 pole, suitable ratingcontactor -L&T,Crompton, C&S,GE.(b) 02 Nos MCCB of sutable type and rating for DG/Mains incoming-L&T/GE/ C&S(LG ).© Frequency meter -Enercon/Caddle/ AE/ C&S(LG).(d) Ammmeter with suitable CT,s with selector switch-Enercon/Caddle/AE.(e)Voltmeter with suitable switch-Enercon/Caddle/AE.(f) Frequency meter -Enercon/Caddle/AE. 88 AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:-(a) Start/ stop settings including delay and timing setting duly programmable.(b) programmable timing for idle running .(c) Auto/ manual option for each contractor .(d) Self starting kiks for three times or as per programme .(e) Alarm for any fault with buzzer and indicating lamp .(f) One main supply voltage monitor .(g) One alternator supply voltage monitor .(h) One set of DC control relays and timers.(j) One set of control relays for the automatic control system . 89 (E) RCC FOUNDATION:- RCC FuoundationM 20(as per manufacturer design) ,450 mm overall height, 300mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves.(Make of Alternator:-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti . 90 (F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts. 91 (G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:-(i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil.(iii) fuel strainer.(iv) Pipe for fuel.(v) Air vent.(vi) Mannually operated one no. fuel pump. 92 (H) INSPECTION PORT :-Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.(J) VENTILATION :- Forced with suitable fan. 93 (K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB.(a) Earthing panel (Neutral body).(b) Control Panel .© Cable leads for batteries.(d) Power cable to euipment.(e) Self StarterNOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted .(b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted . 94 SCHEDULE A PART XIV A (Fire Alarm & Fire Fighting) 95 SCHEDULE A PART XIV B (Fire Alarm & Fire Fighting) 96 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade 97 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade 98 Supplying installation testing and commissioning of addressable electronic Hooter with audioable range of 25 to 30 mtr with suitable output wattage.These Hooter should be such that they are capable of public announcement as well as used for fault as requried. 99 S & F active repeater ,silence ,mute, reset,accept,evacute and test controls, DX control panels require a 24 V dc supply and an RS485 card required when used with ZX control panel. 100 Fire pump electric driven engine horizontal end suction cetrifugal type as per relevant IS with CI casing bronze impeller and stainless steel shaftmounted on heavy duty bearings suitable continuous operation 0-150% of rated capacity for 415 Volt 3 Phase 50m Hz AC supply for discharge head 900 LPM at 36 m Head complete with automatic start system in case electric supply failure and mannual Start off having battery of appropriate rating, self starter,foundationcomplete all as directed by Engineer-in-Charge. makes: shakti pumps india ltd/Kirloskar/CG 101 Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 3.15 mm thick CRCA sheet and MS angle of suitable size on PCC 1:2:4 type B-1 platform frame factory fabricated with front and back open able double door systemlouvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, factory fabricated (Factory approved from CPRI)having modern fabrication and followed by powder coat painting comprising of the following:- (Main Elect Panel ) 102 (a) MCCB 415 volts .4P ,200 Amps 16 KA(incoming)-01 No(b) MCCB 415 volts .4P,63Amps 16 KA(O/G)-03 Nos (for Fire pump & lift)(c) MCCB 415 volts .4P,63 Amps 16 KA(O/G)-01 Nos (for Fire alarm Panel)(d) MCCB 415 volts .4P,100Amps 25 KA(O/G)-01 Nos (for bldg)(e) Space for starter - 01 No(f) Bus bar chamber with and including Aluminium strips (set 4 nos) suitable for 300 ampsduly mounted on porcelain insulators-01 Set(g) DigitalAmp meter 3 phprogrammebale type with suitable CTs -01 Set(h) Digitalvolt meter 3 phprogrammebale type suitable for 500 Volt -01 Set (j)LED Phase indicator R, Y & B-01 Set 103 S&F water type extinguisher(IS: 15683) 9kg capacity 104 S& F light weight squeenze grip type CO2 Extinguisher(IS: 15683) 4.5 kg capacity 105 S&F Dry power (ABC) extinguisher(IS: 15683) 9 kg capacity 106 S&F Dry Mechanical foam extinguisher (IS: 15683) 9 ltr capacity 107 S&F Fire buckets(Dry sand) (IS:2546) 108 S&FFire bucket stand post 109 SCHEDULE A PART XV (Heating Appliances) 110 SCHEDULE A PART XVI (Lightening Conductor) 111 SCHEDULE A PART XVII (Dismantling / Demolition)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 14
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 49,150
Statutory Bodies & Commissions/Committees No of Bidders 3
35.
Agriculture #9749058 Technical Bid
Supply Of Tools, Instruments, Safety Equipment And Workshop Accessories To The Office Of The Assistant Executive Engineer (Agri), Wayanad , List Of Tools And Machineries , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr- V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance. , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars. , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection. , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles. , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop- Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use. , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance. , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip. , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300–500 Gm, Handle Made Of Fiberglass , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation. , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58–60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End. , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust- Resistant Finish 230 Mm Length 1.5 Kg. , Adjustable Torque Wrench With Working Range 25–135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick- Release Mechanism. , Heavy-Duty Adjustable Torque Wrench, Range 70–340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate. , High-Capacity Torque Wrench, Range 135–540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate. , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish. , Vernier Calipers Made Of Stainless Steel, Precision- Ground And Finished, With A Measuring Range Of 0–200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case. , Outside Micrometer (0–25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards. , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits. , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20–170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards. , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations. , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875. , Portable True-Rms Digital Multimeter Of High- Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data- Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate. , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40–60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate. , Handheld Vibration Meter Shall Be Capable Of Measuring Vibration Velocity, Displacement, And Acceleration Within A Frequency Range Of 10 Hz To 1 Khz Or Higher Complying Iso 2954. The Instrument Shall Display Rms Or Peak Values In Standard Engineering Units (Mm/S, Μm, M/S²). It Shall Feature A Detachable Accelerometer Probe, Communicate With Pc Computer For Statistics And Printing By The Optional Cable And The Software. The Device Shall Be Compact, Battery-Operated, And Suitable For Predictive Maintenance Of Rotating Machinery. It Shall Be Supplied With Transducer, Magnetic Base, Extension Cable, And Carrying Case. , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards , Clamp-On Earth Leakage Meter Shall Measure Ac Leakage Current In Grounding And Neutral Conductors Without Disconnection, Within A Range Of 0.1 Ma To 100 A Or Higher. The Clamp Jaw Shall Accommodate Conductors Up To 50 Mm Diameter. The Instrument Shall Comply With Cat Iii 600 V Safety Category, Have A Back-Lit Display, And Be Supplied With Batteries, Manual, And Calibration Certificate. , Infrared Thermometer (Ir Gun) Shall Measure From - 50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate. , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2–200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use. , Digital Motor Checker Equipped With A Backlit Lcd Display, To Provide Accurate Measurements Of Key Electrical Parameters Including Insulation Resistance (0–200 M?) And Inductance (0–200 Mh), Operates On Alkaline Batteries, Featuring Low Battery Indication For Reliable Field Use, Precise Readings With An Accuracy Of ±2%. Complies With Iec 61010-1: Safety Requirements For Electrical Equipment For Measurement. , Smart Battery Charger Shall Provide Automatic Multi- Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal. , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards. , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360- Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. , 10Pcs Carburetor Adjusting Tool Kit Including: 21- Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use. , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double- Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment – Spark Plug Testers, Or Equivalent International Standards , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220–230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 , Soldering Station Operating On A 220–240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances – Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices . , Compact, Durable, And Easy To Operate Portable High- Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections. , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½”) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12–M22) And High-Strength Bolts (M12–M16) In Vehicle And Machinery Maintenance Applications , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220–240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual. , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350–550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances – Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. , Bench Vice Of Heavy-Duty Engineer’S Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard. , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold- Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8–1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3–4 Ventilated Shelves With Acid- Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm. , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3–5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm. , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220–240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion- Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety. , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle , Industrial Locker Cabinet (24-Door Type), Fabricated From 22-Gauge Mild Steel Sheet Pre-Treated And Powder-Coated For Corrosion Resistance And Smooth Finish With A Rigid Frame Structure, Each Locker Compartment With Individual Mechanical Key Locks Shall Measure Approximately 18 (D) × 12 (W) × 12 (H), With A Total Cabinet Size Of About 18 (D) × 48 (W) × 78 (H). A Load Capacity Of Minimum 10 Kg Including Ventilation Slots And Numbering Provision For Each Compartment , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory- Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression. , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1–3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask). , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592. , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865. , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules. , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields. , Ppe Industrial Gloves: For Mechanical Work—Leather Or Nitrile (Is 6994); For Chemical Work—Pvc/Neoprene (En 374); For Electrical Insulation—Rubber Class 0 (Is 4770). , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic. , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471. , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date. , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops. , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat- Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme- Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use. , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 5 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti- Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service. , The Hydraulic Bottle Jack Of 10-Ton Rated Capacity, Suitable For Lifting Tractors, Vehicles, Or Heavy Structures. The Jack Body Shall Be Made Of High-Tensile Steel With Precision Machining For Durability And Stability. It Shall Have A Lifting Range From Approximately 200 Mm To 400 Mm, Incorporating A Screw Extension On The Ram For Height Adjustment. The Hydraulic System Shall Be Fitted With A Built-In Safety Overload Valve And High-Quality Seals To Prevent Leakage. The Operating Handle Shall Be Detachable And Designed For Easy Pumping Action. The Base Shall Be Wide And Stable To Ensure Safety During Lifting Operations. The Jack Shall Conform To Is 10672 / Asme B30.1 Or Equivalent Standards, And Finished With Corrosion-Resistant Paint. Supplied Fully Assembled, Tested, And Filled With Hydraulic Oil. , The Jack Stands Shall Be Of Heavy-Duty Ratchet Or Pin- Lock Type, Designed To Support Loads Up To 3 Tons Per Pair. Each Stand Shall Be Fabricated From High-Grade Steel With A Broad, Stable Base And A Ratcheting Support Column Providing Positive Load Engagement. The Height Adjustment Range Shall Be Approximately 290 Mm To 430 Mm, With Fine-Tooth Ratchet Mechanism Or Pin-Lock System Ensuring Secure Positioning. Each Stand Shall Include A Safety Locking Mechanism To Prevent Accidental Lowering Under Load. The Saddle Shall Have A Contoured Top For Stable Seating Under Vehicle Lifting Points. All Structural Components Shall Be Fully Welded And Finished With Corrosion-Resistant Powder Coating. The Stands Shall Meet Asme-Pase / Ansi Pald Or Equivalent Safety Standards. Supplied As A Matched Pair, Factory-Tested For Load Stability And Mechanical Integrity. , The Hydraulic Engine Hoist Shall Be A Foldable, Mobile Workshop Crane With A 2 Ton Rated Lifting Capacity, Suitable For Lifting, Removing, And Installing Vehicle Engines Or Heavy Assemblies. The Frame Shall Be Made Of High-Strength Steel Sections With A Reinforced Boom, Hydraulic Lifting Ram, And Heavy-Duty Castor Wheels For Mobility. The Boom Shall Have Adjustable Reach Positions (E.G., 500 Kg, 1000 Kg, 1500 Kg, 2000 Kg) With A Lifting Range Of Approximately 0 – 2300 Mm. The Hydraulic Ram Shall Be Operated Via A Detachable Handle And Equipped With A Safety Overload Valve To Prevent Overloading. The Hoist Shall Feature A Folding Design For Space-Saving Storage, And A 360° Swivel Hook With Safety Latch For Secure Load Handling. The Finish Shall Be Industrial Enamel Or Powder-Coated For Corrosion Protection. The Equipment Shall Comply With Is 7631 / Asme B30.20 / Ce Standards And Supplied Ready For Operation. , The Transmission Jack Shall Be A Hydraulic Telescopic Type Suitable For Removing And Installing Vehicle Transmissions Or Gearboxes From Underneath The Lift. The Rated Load Capacity Shall Be 0.5 Ton, With A Lifting Range Of Approximately 1100 Mm To 1900 Mm. The Lifting Mechanism Shall Be Actuated By A Foot-Operated Hydraulic Pump For Hands-Free Operation. The Tilting Head Plate Shall Provide Front, Rear, And Side Adjustment Through Fine-Thread Screws To Aid Alignment During Installation. The Base Shall Be Wide And Equipped With Four Swivel Castor Wheels For Stability And Maneuverability. The Unit Shall Have A Safety Overload Valve, Heavy-Duty Hydraulic Seals, And A Controlled Lowering Valve. It Shall Conform To Asme Pase / En 1494 Standards And Be Supplied Fully Assembled And Oil-Filled. , The Chain Block Shall Be A Manual, Hand-Operated Lifting Device Of 2 Ton Rated Capacity, Suitable For Workshop And Field Lifting Applications. It Shall Have A Mechanical Gear System Enclosed In A Steel Casing, Operating A Load Chain Made Of Grade 80 Alloy Steel With High Tensile Strength. The Standard Lift Height Shall Be 3 M – 6 M, With An Option For Extended Lift Lengths. The Mechanism Shall Incorporate A Load Brake With Dual Pawls For Positive Load Holding And Safety Hooks With Safety Latches At Both Ends. The Hand Chain Shall Run Smoothly On Precision-Machined Sprockets. The Unit Shall Conform To Is 3832 / Asme B30.16 / En 13157, With Load Testing Certificates And Corrosion- Resistant Paint Finish.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
36.
Drinking Water Supply and Sanitation #9738328 Technical Bid
Tender for Reclamation Of Existing Dumpsite Through Bio-Mining Process By Excavating The Existing Mixed Compacted Garbage Which Underwent Biological Degradation In Land Portion Earmarked By Municipality And Loosening The Garbage, Spraying Consortium Of Micro Organizing To Sanitize And Stabilize The Loosened Material And Helping Them For Stabilization Controlling Malodors By Spraying Of Suitable Microbial In Column, Sieving Them After Stabilization By Using Mechanical Sieving Machine Or Any Other Equipment At The Cost Of Bidder Adopting Eco Friendly And Nan Polluting Process In Order To Reduce The Impact Of Dumping Site In The Adjacent Area. Further Segregating The Excavated Garbage Into As Categories As Possible For The Cost Of Bidder Include Cost Of Bidders Risk And Cost For Sieving The Excavated Garbage Storing The Segregated Materials. Deployment Of Necessary Man Power Materials Equipment Tool And Construction Of Plant And Sheds And Creation Of Facilities For Handing Separation, Segregating And Storing For The Operation Of The Plant. Leveling The Earth Surfaces By Bull Dozer Or Any Other Earth Moving Equipment. Providing Security Arrangements For The Plan Project. Site, Machineries Equipment Etc. At The Cost Of Bidder Competing The Work Within The Contract Period A Directed By The Departmental Officers. The Entire Segregated Materials All Be Sold/Disposed Within Fifteen Days. The Bidder Should Maintain The Ambient Air Quality Within The Standard Prescribed And The Activities Should Not Attract Any Public Complaints Provision For Man Hole Raising And New Frc Frame Cover Fixing Work .The Rate Inclusive Of All Charges Etc, Complete As Per Standard Specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 32,201
Statutory Bodies & Commissions/Committees No of Bidders 3
West Bengal View Result →
39.
Agriculture #9685449 Price Bid
Tender For Annual Plan 2025-26- Support To Farm Mechanisation Establishment Of Farm Machinery Clinic- Purchase Of Tools And Equipments For Agri Clinic At Chc Kozha , Hand Tools , A) Screwdriver Bits (26 Pcs, 25 Mm Length, S2 Steel) B) Phillips (Ph): Ph0, Ph1, Ph2, Ph3 C) Pozidriv (Pz): Pz0, Pz1, Pz2, Pz3 D) Slotted (Sl): Sl4, Sl5.5, Sl7 E) Hex (H): H2, H3, H4, H5, H6, H7, H8, H10 F) Torx (T): T10h, T15h, T20h, T25h, T27h, T30h, T40h G) Bit Holder (1 Pc) - 1/4 Hex H) Hexagonal Sockets (9 Pcs) - Sizes: 4, 4.5, 5, 5.5, 6, 7, 8, 9, 10 Mm I) Star Sockets (5 Pcs) - Sizes: E4, E5, E6, E7, E8 J) Ratchet Wrench (1 Pc) - 1/4 Drive, 45 Teeth (Reversible) K) Extension Bars (3 Pcs) - Lengths: 50 Mm (2), 100 Mm (4), 150 Mm (6) L) Universal Joint (1 Pc) - 1/4 Drive M) Three-Way Adaptor (1 Pc) - 3/8 Female × 1/4 Male N) Spinner Handle (1 Pc) - 1/4 × 150 Mm O) Flexible Extension Bar (1 Pc) - 1/4 × 150 Mm 4. Combination Spanners (17 Pcs) - Sizes: 6, To 24 Mm 5. Flare Nut Spanners (5 Pcs) - Sizes: 8×10, 10×12, 11×13, 12×14, 17×19 Mm 6. Hex Key Set (10 Pcs) - Sizes: 2.5, 3, 4, 5, 6, 7, 8, 10, 12, 14 Mm 7. Machinist Hammer (1 Pc) - 300 G With Fiberglass Or Wooden Handle 8. Combination Pliers (1 Pc) - 7 9. Locking Pliers (1 Pc) - 10 Curved Jaw Lock Wrench 10. Slotted Screwdrivers (2 Pcs) - Sl6.5 × 100 Mm And Sl6.5 × 150 Mm 11. Phillips Screwdrivers (2 Pcs) - Ph2 × 100 Mm And Ph2 × 150 Mm 12. Stubby Screwdrivers (2 Pcs) - Ph2 × 38 Mm And Sl6.5 × 38 Mm All Sockets, Spanners, And Ratchets Shall Be Made From Chrome Vanadium Steel (Cr-V), Heat-Treated, And Chrome-Plated For Corrosion Resistance. Screwdriver Bits Shall Be Of S2 Alloy Steel For High Torque Resistance. Ratchets Shall Have A Minimum Of 45 Teeth With A Quick-Release And Reversible Mechanism. All Tools Shall Conform To Din / Iso Standards Or Equivalent. Suitcase Colour Should Be Standard Industrial Colour (Black / Blue / Grey Or Similar) , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr-V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance. , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars. , Combination Plier 6 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety. , Combination Plier 8 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety. , Circlip Plier Internal 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated. , Circlip Plier External 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated. , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection. , Diagonal Cutting Pliers, 6, Made Of Forged Alloy Steel, With Induction-Hardened Cutting Edges And Insulated Handles Suitable For Cutting Wires And Small Metal Parts. , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles. , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 40 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use. , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance. , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip. , Ball Pein Hammer With 300 Gm Forged Steel Head, Hardened And Tempered. Fitted With A Strong Fiberglass Handle Suitable For Riveting, Striking, And Metal Forming. , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300-500 Gm, Handle Made Of Fiberglass , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation. , Sledge Hammer With 500 Gm (2 Lb) Drop-Forged Steel Head, Hardened And Tempered. Handle Of Strong Wooden Or Fiberglass Construction, Securely Fixed To Head. , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58-60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End. , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust-Resistant Finish 230 Mm Length 1.5 Kg. , Adjustable Torque Wrench With Working Range 25-135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick-Release Mechanism. , Heavy-Duty Adjustable Torque Wrench, Range 70-340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate. , High-Capacity Torque Wrench, Range 135-540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate. , Measuring Tools , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish. , Vernier Calipers Made Of Stainless Steel, Precision-Ground And Finished, With A Measuring Range Of 0-200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case. , Outside Micrometer (0-25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards. , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits. , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20-170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards. , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations. , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875. , Auto Electrial And Pump , Portable True-Rms Digital Multimeter Of High-Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data-Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate. , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40-60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate. , Handheld Vibration Meter Shall Be Capable Of Measuring Vibration Velocity, Displacement, And Acceleration Within A Frequency Range Of 10 Hz To 1 Khz Or Higher Complying Iso 2954. The Instrument Shall Display Rms Or Peak Values In Standard Engineering Units (Mm/S, ?M, M/S²). It Shall Feature A Detachable Accelerometer Probe, Communicate With Pc Computer For Statistics And Printing By The Optional Cable And The Software. The Device Shall Be Compact, Battery-Operated, And Suitable For Predictive Maintenance Of Rotating Machinery. It Shall Be Supplied With Transducer, Magnetic Base, Extension Cable, And Carrying Case. , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards , Infrared Thermometer (Ir Gun) Shall Measure From -50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate. , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2-200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use. , Smart Battery Charger Shall Provide Automatic Multi-Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal. , Tractor And Automobile , Manual Engine Stand Fabricated From High-Strength Heavy-Duty Mild Steel Tubular Sections, Finished With Powder Coating For Corrosion Resistance And Durability With A Lifting Capacity Of 2000 Lbs (Approximately 900 Kg), A Manual Locking Mechanism For Secure Positioning, And Four Swivel Casters For Easy Mobility And Stability. The Equipment Shall Conform To The General Safety And Design Provisions Of Is 8610:1977 (Automobile Service Equipment - Engine Stand) Or Equivalent International Standards, Ensuring Mechanical Stability, Ease Of Rotation, And Operator Safety. , Spring Compressor - Head Valve Type, Of Reputed Make Made Of High-Strength Carbon Steel With A Corrosion-Resistant Finish, Having An Overall Length Of Approximately 750 Mm And Weight Around 700 G Conforming To Relevant Standards For Hand Tools Such As Is 5781 / Is 6131 / Iso 6787 Or Equivalent. , Piston Ring Compressor (Set Of 3) Of Reputed Make, Made Of Hardened And Tempered Alloy Or Carbon Steel With A Polished Or Chrome-Plated Corrosion-Resistant Finish, And Provided With A Ratchet Or Key-Type Locking Mechanism For Uniform Compression And Easy Releasewith An Adjustable Diameter Range Suitable For Standard Engine Pistons (50 Mm To 125 Mm With 75 Mm Height, 90 Mm To 175 Mm With 100 Mm Height, And 90 Mm To 175 Mm With 150 Mm Height), Conforming To Relevant Standards Such As Is 7347 / Iso 1174 To Be Supplied Complete With Necessary Tightening Wrench Or Handle. , Portable Diesel Injector Nozzle Pop Tester, With A Dual-Scale Pressure Gauge (0-400 Bar / 0-6000 Psi), A Manual Hydraulic System With An Oil Cup Capacity Of 0.8 Litres, Constructed From High-Grade Plastic, And A Rugged Metallic Pump Body, Approximate Weight Of 4.25 Kg, Conforms To Iso 4113 (Calibration Fluid For Diesel Injection Equipment) And Iso 4008-1 / Iso 4008-2 (Diesel Fuel Injection Test Equipment - Testing Of Injection Pumps And Injectors). , Injector Puller Set (8 Pcs), Including Eight Precision-Engineered Oxidized Carbon Steel Components Comprising An Inertia Hammer, A Joint For Accessing Hard-To-Reach Areas, And Six Threaded Adapters With Sizes M12×1.75, M17×1, And M27×1, Ensuring Compatibility With Injectors From Major Manufacturers, Hammer Length Of 350 Mm All Conforms To Iso 6789:2017 (Torque Tools - Requirements And Test Methods) And Din 3122 (Hand-Operated Tools For Mechanical Drive). , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Clutch Alignment Tool Of Reputed Make, Made Of Durable Carbon Steel, Resistant To Wear And Corrosion, And Capable Of Withstanding Repeated Workshop Use. The Tool Shall Be Adjustable Or Provided In A Set To Suit Various Pilot Bearing And Clutch Plate Diameters (Approximately 14 Mm To 28 Mm Or Equivalent Range), Conforming To Is 7347 / Iso 1174 Or Equivalent For Hand Tools, , Valve Seat & Face Cutter Set Of Seat Cutters, Face Cutters, Arbors, And Pilots (20 Nos) Of High-Grade Alloy Steel With Precision-Ground Cutting Edges, Hardened And Tempered To Maintain Cutting Efficiency, Conforms To Is 5517:1993 (Specification For Cutting Tools - General Requirements) And Iso 513 (Classification And Application Of Cutting Tool Materials) , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360-Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. , 10Pcs Carburetor Adjusting Tool Kit Including: 21-Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use. , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double-Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment - Spark Plug Testers, Or Equivalent International Standards , Portable Fuel And Vacuum Gauge Tester Kit For Testing Fuel Pump Pressure, Fuel Pump Vacuum, Carburettor Intake, And Manifold Vacuum Systems In Petrol Engines With Dual Gauges - A Pressure Gauge Ranging From 0 To 10 Psi (0-0.7 Kg/Cm²) And A Vacuum Gauge Ranging From 0 To 28 In-Hg (0-70 Cm-Hg) - For Accurate Measurement Of Engine Fuel And Air System Performance, With Standard Automotive Fittings For Quick Connection To Various Fuel And Vacuum Lines And Conforming To Is 1446: Automotive Test Equipment - Pressure And Vacuum Gauges Or Equivalent International Standards Like Sae J1812 For Fuel System Testing Instruments. , Petrol Engine Compression Tester Kit (400 Mm) Including Threaded Adaptors In Sizes M10, M12, M14, And M18, Along With Two Rubber Cone Ends For Both Threaded And Non-Threaded Testing, Equipped With Straight And Angled Push-On Connectors And A 400 Mm Flexible Hose, To Diagnose Issues Related To Piston Rings, Valves, Or Head Gaskets, Suitable For Cars, Motorcycles, And Small Petrol Engines. , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220-230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 , Soldering Station Operating On A 220-240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices . , Compact, Durable, And Easy To Operate Portable High-Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections. , Double Piston Lever Grease Gun Delivering Up To 2.4 Grams Of Grease Per Stroke, Pressures Up To 6000 Psi, With A Double-Piston Mechanism, Compact And Lightweight (Approx. 2 Kg). , Durable And Easy-To-Use Steel Lubrication Oil Dispenser Can For Smooth And Controlled Lubrication With A 500 Ml Capacity, Made From High-Quality Steel With A Powder-Coated Finish, The Can Is Lightweight (Approx. 200 G), Waterproof, And Ergonomically Designed For Comfortable Handling And Precise Oil Flow. , Power Tools And Equipment , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12-M22) And High-Strength Bolts (M12-M16) In Vehicle And Machinery Maintenance Applications , Heavy-Duty Angle Grinder, Of Reputed Make, Single Phase 220-240 V, 50/60 Hz Ac Supply, Input Power 2200 W No-Load Speed 8500 Rpm To Use With 180 Mm (7) Diameter Abrasive Wheels, And Equipped With Side Handle, Wheel Guard, And Spindle Lock A 2.0 M Power Supply Cord And Conforming To Is 7554 / Iec 60745-2-3 / Iso 11148-7 Or Equivalent Standards (Low Vibration Level (=6.5 M/S²), Sound Pressure Level Not Exceeding 91 Db(A)). , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual. , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350-550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. , Portable Air Compressor, Of Reputed Make, Single Phase 230 V, 50 Hz Ac Supply, Fitted With An Electric Motor Of 2.0 Hp (1.5 Kw) A Maximum Working Pressure Of 8 Bar, Free Air Delivery Not Less Than 200 Lpm (7.2 Cfm), And A Motor Speed Of 2850 Rpm. Air Receiver Tank Of 50 Liters Capacity, Conforming To Is 5456 / Is 2825 Standards And The Compressor Shall Conform To Is 10437 / Iso 1217, And Fitted With Pressure Gauge, Safety Valve, Drain Valve, And Automatic Pressure Switch. The Complete Unit Shall Be Portable, Vibration-Damped, And Equipped With Wheels And Handle For Easy Movement. , Single Phase Annual Rate Contract Welding Machine Of Reputed Make, With Inverter-Based Igbt Technology To Be Operated On Ac 220V ±15%, 50/60 Hz Single Phase Supply And Deliver A Welding Output Current Up To 400 Annual Periodical Maintenance With A Duty Cycle Of Not Less Than 60%, An Efficiency Of Minimum 80% And Power Factor Not Less Than 0.73, With Insulation Class F And Protection Grade Ip21 As Per Is 2879 / Is 3024 Or Equivalent International Standards. And Necessary Accessories Such As Welding Cable, Electrode Holder, And Earth Clamp Etc. Should Be Included. , Mig (Metal Inert Gas) Welding Machine Of Reputed Make, Operate On Single Phase Ac 220V ±15%, 50/60 Hz Having An Output Current Range Of 20-300 Annual Periodical Maintenance With A Duty Cycle Not Less Than 60%, No-Load Voltage Of Approximately 60 V Rated Input Current Of About 19.8 A, Power Factor Not Less Than 0.93, Efficiency Of At Least 85%, Housing Protection Shall Be Minimum Ip21 Conforming To Class F, And, As Per Is 10178 / Is 2879 / Is 3024 , Bench Grinder, Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply Equipped With A 350 W Induction Motor Of 2950 Rpm. Two 200 Mm Diameter Grinding Wheels Each Provided With Eye Shields And Wheel Guards, Heavy-Duty Aluminum Base With Tool Rest, Tool Storage Box, And Safety Accessories Etc. Complete Conforming To Is 302 / Is 6932 / Iec 61029 Or Equivalent. , Furniture And General , Bench Vice Of Heavy-Duty Engineers Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard. , Removable And Corrosion-Resistant Drip Tray Of Size 1200 Mm (L) × 600 Mm (W) × 40 Mm (H) Fabricated From Galvanized Steel Sheet Of Minimum 1.6 Mm Thickness Or 304-Grade Stainless Steel, Ensuring Long Service Life And Resistance To Rust And Chemical Attack, Suitable To Collect Oil, Fuel, And Coolant Spills During Small Engine Maintenance Operations. The Edges Should Be Folded And Reinforced To Prevent Deformation And Improve Rigidity, The Corners Shall Be Welded And Leak-Proof, And The Base Shall Be Slightly Inclined (1-2° Slope) To Facilitate Drainage. It Should Include A Removable Drain Plug Or Outlet Provision (½ Bsp) For Easy Cleaning And Disposal Of Collected Fluids. The Surface Shall Be Smooth, Easy To Clean, And Oil-Resistant, Suitable For Workshop Environments Handling Petrol And Diesel Engines. , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold-Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8-1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 8 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3-4 Ventilated Shelves With Acid-Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm. , Rack For Lubricants Constructed From Treated Wood Or Plywood Frame With Raised-Edge Shelves To Contain Spills. Each Shelf Shall Carry At Least 100 Kg And Be Coated With Oil-Resistant Paint. Suitable For 1-20 L Containers. Approx. Size: 1800 Mm × 1200 Mm × 450 Mm. , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3-5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm. , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220-240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion-Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety. , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle , Industrial Locker Cabinet (24-Door Type), Fabricated From 22-Gauge Mild Steel Sheet Pre-Treated And Powder-Coated For Corrosion Resistance And Smooth Finish With A Rigid Frame Structure, Each Locker Compartment With Individual Mechanical Key Locks Shall Measure Approximately 18 (D) × 12 (W) × 12 (H), With A Total Cabinet Size Of About 18 (D) × 48 (W) × 78 (H). A Load Capacity Of Minimum 10 Kg Including Ventilation Slots And Numbering Provision For Each Compartment , Safety , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression. , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1-3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask). , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592. , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865. , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules. , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields. , Ppe Industrial Gloves: For Mechanical Work-Leather Or Nitrile (Is 6994); For Chemical Work-Pvc/Neoprene (En 374); For Electrical Insulation-Rubber Class 0 (Is 4770). , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic. , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471. , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date. , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops. , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat-Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial Environments. The Pair Shall Be Supplied In Standard Size (Large/Universal Fit) And Shall Bear Proper Labeling Indicating Brand, Size, And Conformity To Relevant Standards. , Lifting And Hoisting , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme-Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use. , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 5 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti-Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service. , The Hydraulic Bottle Jack Of 10-Ton Rated Capacity, Suitable For Lifting Tractors, Vehicles, Or Heavy Structures. The Jack Body Shall Be Made Of High-Tensile Steel With Precision Machining For Durability And Stability. It Shall Have A Lifting Range From Approximately 200 Mm To 400 Mm, Incorporating A Screw Extension On The Ram For Height Adjustment. The Hydraulic System Shall Be Fitted With A Built-In Safety Overload Valve And High-Quality Seals To Prevent Leakage. The Operating Handle Shall Be Detachable And Designed For Easy Pumping Action. The Base Shall Be Wide And Stable To Ensure Safety During Lifting Operations. The Jack Shall Conform To Is 10672 / Asme B30.1 Or Equivalent Standards, And Finished With Corrosion-Resistant Paint. Supplied Fully Assembled, Tested, And Filled With Hydraulic Oil. , The Jack Stands Shall Be Of Heavy-Duty Ratchet Or Pin-Lock Type, Designed To Support Loads Up To 3 Tons Per Pair. Each Stand Shall Be Fabricated From High-Grade Steel With A Broad, Stable Base And A Ratcheting Support Column Providing Positive Load Engagement. The Height Adjustment Range Shall Be Approximately 290 Mm To 430 Mm, With Fine-Tooth Ratchet Mechanism Or Pin-Lock System Ensuring Secure Positioning. Each Stand Shall Include A Safety Locking Mechanism To Prevent Accidental Lowering Under Load. The Saddle Shall Have A Contoured Top For Stable Seating Under Vehicle Lifting Points. All Structural Components Shall Be Fully Welded And Finished With Corrosion-Resistant Powder Coating. The Stands Shall Meet Asme-Pase / Ansi Pald Or Equivalent Safety Standards. Supplied As A Matched Pair, Factory-Tested For Load Stability And Mechanical Integrity. , The Hydraulic Engine Hoist Shall Be A Foldable, Mobile Workshop Crane With A 2 Ton Rated Lifting Capacity, Suitable For Lifting, Removing, And Installing Vehicle Engines Or Heavy Assemblies. The Frame Shall Be Made Of High-Strength Steel Sections With A Reinforced Boom, Hydraulic Lifting Ram, And Heavy-Duty Castor Wheels For Mobility. The Boom Shall Have Adjustable Reach Positions (E.G., 500 Kg, 1000 Kg, 1500 Kg, 2000 Kg) With A Lifting Range Of Approximately 0 - 2300 Mm. The Hydraulic Ram Shall Be Operated Via A Detachable Handle And Equipped With A Safety Overload Valve To Prevent Overloading. The Hoist Shall Feature A Folding Design For Space-Saving Storage, And A 360° Swivel Hook With Safety Latch For Secure Load Handling. The Finish Shall Be Industrial Enamel Or Powder-Coated For Corrosion Protection. The Equipment Shall Comply With Is 7631 / Asme B30.20 / Ce Standards And Supplied Ready For Operation. , The Tractor Splitting Stand Shall Be Designed For Safe Splitting And Assembly Of Tractors During Clutch Or Transmission Repairs. The Unit Shall Consist Of Two Independent Rolling Stands, One Front And One Rear, Each With Adjustable Height And Wheel-Mounted Base To Facilitate Easy Alignment And Movement Of Tractor Halves. The Front Cradle Shall Support The Clutch Housing Or Engine Section, While The Rear Stand Supports The Transmission Or Rear Axle Section. Both Stands Shall Be Constructed From Heavy-Duty Fabricated Steel Sections With Mechanical Screw Or Hydraulic Lifting Arrangements Providing A Height Range Of 400 Mm - 800 Mm. The Stands Shall Be Fitted With Locking Pins, Adjustable Supports, And Safety Chains To Prevent Accidental Movement. Load Capacity Shall Be Minimum 2 Tons Per Pair. The Entire Unit Shall Be Powder-Coated For Durability And Conform To Workshop Safety Standards For Agricultural Machinery Maintenance. , The Transmission Jack Shall Be A Hydraulic Telescopic Type Suitable For Removing And Installing Vehicle Transmissions Or Gearboxes From Underneath The Lift. The Rated Load Capacity Shall Be 0.5 Ton, With A Lifting Range Of Approximately 1100 Mm To 1900 Mm. The Lifting Mechanism Shall Be Actuated By A Foot-Operated Hydraulic Pump For Hands-Free Operation. The Tilting Head Plate Shall Provide Front, Rear, And Side Adjustment Through Fine-Thread Screws To Aid Alignment During Installation. The Base Shall Be Wide And Equipped With Four Swivel Castor Wheels For Stability And Maneuverability. The Unit Shall Have A Safety Overload Valve, Heavy-Duty Hydraulic Seals, And A Controlled Lowering Valve. It Shall Conform To Asme Pase / En 1494 Standards And Be Supplied Fully Assembled And Oil-Filled. , The Chain Block Shall Be A Manual, Hand-Operated Lifting Device Of 2 Ton Rated Capacity, Suitable For Workshop And Field Lifting Applications. It Shall Have A Mechanical Gear System Enclosed In A Steel Casing, Operating A Load Chain Made Of Grade 80 Alloy Steel With High Tensile Strength. The Standard Lift Height Shall Be 3 M - 6 M, With An Option For Extended Lift Lengths. The Mechanism Shall Incorporate A Load Brake With Dual Pawls For Positive Load Holding And Safety Hooks With Safety Latches At Both Ends. The Hand Chain Shall Run Smoothly On Precision-Machined Sprockets. The Unit Shall Conform To Is 3832 / Asme B30.16 / En 13157, With Load Testing Certificates And Corrosion-Resistant Paint Finish.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 8,900
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
41.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
42.
Agriculture #9567643 Technical Bid
Tender For Supply Of Tools/ Diagnostic Devices/ Workshop Equipments/ Spare Parts To Farm Machinery Clinic, Kollam. (Annual Plan 2025-26 - Support To Farm Mechanization) , Part 1-Hand Tools , Mechanic Tool Set Supplying A Comprehensive Professional-Grade The Mechanics Tool Kit With A Durable, Impact-Resistant Moulded Suitcase (Bmc Case) With Designated Compartments For Each Component, Ensuring Easy Portability And Organization And Includes The Chrome-Vanadium Tools And Accessories Listed As Appendix 1 1. 1/2 Drive Set A) Hexagonal Socket (19 Pcs) - Sizes: 8, To 32 Mm B) Star Socket (5 Pcs) - Sizes: E10, E12, E14, E16, E20 C) Flex Handle (1 Pc) - Length: 375 Mm D) Ratchet Wrench (1 Pc) - 1/2 Drive, 45 Teeth (Reversible) E) Extension Bars (2 Pcs) - Lengths: 75 Mm (3), 250 Mm (10) F) Universal Joint (1 Pc) - 1/2 Drive G) Three-Way Adaptor (1 Pc) - 1/2 Female × 3/8 Male H) Spark Plug Sockets (2 Pcs) - Sizes: 16 Mm And 21 Mm I) L-Handle (1 Pc) - 1/2 × 10 2. 3/8 Drive Set A) 12-Point Socket (15 Pcs) - Sizes: 6, To 22 Mm B) Ratchet Wrench (1 Pc) - 3/8 Drive, 45 Teeth (Reversible) C) Extension Bars (2 Pcs) - Lengths: 75 Mm (3), 150 Mm (6) D) Universal Joint (1 Pc) - 3/8 Drive 3. 1/4 Drive Set A) Screwdriver Bits (26 Pcs, 25 Mm Length, S2 Steel) B) Phillips (Ph): Ph0, Ph1, Ph2, Ph3 C) Pozidriv (Pz): Pz0, Pz1, Pz2, Pz3 D) Slotted (Sl): Sl4, Sl5.5, Sl7 E) Hex (H): H2, H3, H4, H5, H6, H7, H8, H10 F) Torx (T): T10h, T15h, T20h, T25h, T27h, T30h, T40h G) Bit Holder (1 Pc) - 1/4 Hex H) Hexagonal Sockets (9 Pcs) - Sizes: 4, 4.5, 5, 5.5, 6, 7, 8, 9, 10 Mm I) Star Sockets (5 Pcs) - Sizes: E4, E5, E6, E7, E8 J) Ratchet Wrench (1 Pc) - 1/4 Drive, 45 Teeth (Reversible) K) Extension Bars (3 Pcs) - Lengths: 50 Mm (2), 100 Mm (4), 150 Mm (6) L) Universal Joint (1 Pc) - 1/4 Drive M) Three-Way Adaptor (1 Pc) - 3/8 Female × 1/4 Male N) Spinner Handle (1 Pc) - 1/4 × 150 Mm O) Flexible Extension Bar (1 Pc) - 1/4 × 150 Mm 4. Combination Spanners (17 Pcs) - Sizes: 6, To 24 Mm 5. Flare Nut Spanners (5 Pcs) - Sizes: 8×10, 10×12, 11×13, 12×14, 17×19 Mm 6. Hex Key Set (10 Pcs) - Sizes: 2.5, 3, 4, 5, 6, 7, 8, 10, 12, 14 Mm 7. Machinist Hammer (1 Pc) - 300 G With Fiberglass Or Wooden Handle 8. Combination Pliers (1 Pc) - 7 9. Locking Pliers (1 Pc) - 10 Curved Jaw Lock Wrench 10. Slotted Screwdrivers (2 Pcs) - Sl6.5 × 100 Mm And Sl6.5 × 150 Mm 11. Phillips Screwdrivers (2 Pcs) - Ph2 × 100 Mm And Ph2 × 150 Mm 12. Stubby Screwdrivers (2 Pcs) - Ph2 × 38 Mm And Sl6.5 × 38 Mm All Sockets, Spanners, And Ratchets Shall Be Made From Chrome Vanadium Steel (Cr-V), Heat-Treated, And Chrome-Plated For Corrosion Resistance. Screwdriver Bits Shall Be Of S2 Alloy Steel For High Torque Resistance. Ratchets Shall Have A Minimum Of 45 Teeth With A Quick-Release And Reversible Mechanism. All Tools Shall Conform To Din / Iso Standards Or Equivalent. Suitcase Colour Should Be Standard Industrial Colour (Black / Blue / Grey Or Similar)- Preferably Tapariya Or Eastman , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr-V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance.Preferably Tapariya Or Eastman , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars.Preferably Tapariya Or Eastman , Combination Plier 6 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety.Preferably Tapariya Or Eastman , Combination Plier 8 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety.Preferably Tapariya Or Eastman , Circlip Plier Internal 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated.Preferably Tapariya Or Eastman , Circlip Plier External 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated.Preferably Tapariya Or Eastman , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection.Preferably Tapariya Or Eastman , Diagonal Cutting Pliers, 6, Made Of Forged Alloy Steel, With Induction-Hardened Cutting Edges And Insulated Handles Suitable For Cutting Wires And Small Metal Parts.Preferably Tapariya Or Eastman , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles.Preferably Tapariya Or Eastman , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles.Preferably Tapariya Or Eastman , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 40 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated.Preferably Tapariya Or Eastman , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated.Preferably Tapariya Or Eastman , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use.Preferably Tapariya Or Eastman , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance.Preferably Tapariya Or Eastman , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip.Preferably Tapariya Or Eastman , Ball Pein Hammer With 300 Gm Forged Steel Head, Hardened And Tempered. Fitted With A Strong Fiberglass Handle Suitable For Riveting, Striking, And Metal Forming.Preferably Tapariya Or Eastman , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300-500 Gm, Handle Made Of Fiberglass Preferably Tapariya Or Eastman , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation.Preferably Tapariya Or Eastman , Sledge Hammer With 500 Gm (2 Lb) Drop-Forged Steel Head, Hardened And Tempered. Handle Of Strong Wooden Or Fiberglass Construction, Securely Fixed To Head.Preferably Tapariya Or Eastman , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58-60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End.Preferably Tapariya Or Eastman , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust-Resistant Finish 230 Mm Length 1.5 Kg.Preferably Tapariya Or Eastman , Adjustable Torque Wrench With Working Range 25-135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick-Release Mechanism.Preferably Tapariya Or Eastman , Heavy-Duty Adjustable Torque Wrench, Range 70-340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate.Preferably Tapariya Or Eastman , High-Capacity Torque Wrench, Range 135-540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate.Preferably Tapariya Or Eastman , Part 2- Description ( Measuring Tools ) , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish.Preferably Mitutoyo Or Bosch , Vernier Calipers Made Of Stainless Steel, Precision-Ground And Finished, With A Measuring Range Of 0-200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case.Preferably Mitutoyo Or Bosch , Outside Micrometer (0-25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate.Preferably Mitutoyo Or Bosch , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate.Preferably Mitutoyo Or Bosch , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards.Preferably Mitutoyo Or Bosch , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits.Preferably Mitutoyo Or Bosch , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20-170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards.Preferably Mitutoyo Or Bosch , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size Preferably Mitutoyo Or Bosch , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations.Preferably Mitutoyo Or Bosch , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875.Preferably Mitutoyo Or Bosch , Part 3- Description ( Auto Electrical And Pump) , Portable True-Rms Digital Multimeter Of High-Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data-Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate.Preferably Continental Or Bosch , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40-60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate.Preferably Continental Or Bosch , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² Preferably Continental Or Bosch , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered Preferably Continental Or Bosch , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² Preferably Continental Or Bosch , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards Preferably Continental Or Bosch , Infrared Thermometer (Ir Gun) Shall Measure From -50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate.Preferably Continental Or Bosch , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2-200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use.Preferably Continental Or Bosch , Smart Battery Charger Shall Provide Automatic Multi-Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal.Preferably Continental Or Bosch , Part 4- Description ( Tractor & Auto Mobile) , Spring Compressor - Head Valve Type, Of Reputed Make Made Of High-Strength Carbon Steel With A Corrosion-Resistant Finish, Having An Overall Length Of Approximately 750 Mm And Weight Around 700 G Conforming To Relevant Standards For Hand Tools Such As Is 5781 / Is 6131 / Iso 6787 Or Equivalent. Preferably Tapariya Or Bosch , Piston Ring Compressor (Set Of 3) Of Reputed Make, Made Of Hardened And Tempered Alloy Or Carbon Steel With A Polished Or Chrome-Plated Corrosion-Resistant Finish, And Provided With A Ratchet Or Key-Type Locking Mechanism For Uniform Compression And Easy Releasewith An Adjustable Diameter Range Suitable For Standard Engine Pistons (50 Mm To 125 Mm With 75 Mm Height, 90 Mm To 175 Mm With 100 Mm Height, And 90 Mm To 175 Mm With 150 Mm Height), Conforming To Relevant Standards Such As Is 7347 / Iso 1174 To Be Supplied Complete With Necessary Tightening Wrench Or Handle.Preferably Tapariya Or Bosch , Portable Diesel Injector Nozzle Pop Tester, With A Dual-Scale Pressure Gauge (0-400 Bar / 0-6000 Psi), A Manual Hydraulic System With An Oil Cup Capacity Of 0.8 Litres, Constructed From High-Grade Plastic, And A Rugged Metallic Pump Body, Approximate Weight Of 4.25 Kg, Conforms To Iso 4113 (Calibration Fluid For Diesel Injection Equipment) And Iso 4008-1 / Iso 4008-2 (Diesel Fuel Injection Test Equipment - Testing Of Injection Pumps And Injectors).Preferably Tapariya Or Bosch , Injector Puller Set (8 Pcs), Including Eight Precision-Engineered Oxidized Carbon Steel Components Comprising An Inertia Hammer, A Joint For Accessing Hard-To-Reach Areas, And Six Threaded Adapters With Sizes M12×1.75, M17×1, And M27×1, Ensuring Compatibility With Injectors From Major Manufacturers, Hammer Length Of 350 Mm All Conforms To Iso 6789:2017 (Torque Tools - Requirements And Test Methods) And Din 3122 (Hand-Operated Tools For Mechanical Drive). , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. Preferably Tapariya Or Bosch , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards.Preferably Tapariya Or Bosch , Valve Seat & Face Cutter Set Of Seat Cutters, Face Cutters, Arbors, And Pilots (20 Nos) Of High-Grade Alloy Steel With Precision-Ground Cutting Edges, Hardened And Tempered To Maintain Cutting Efficiency, Conforms To Is 5517:1993 (Specification For Cutting Tools - General Requirements) And Iso 513 (Classification And Application Of Cutting Tool Materials) Preferably Tapariya Or Bosch , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360-Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. Preferably Tapariya Or Bosch , 10Pcs Carburetor Adjusting Tool Kit Including: 21-Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use.Preferably Tapariya Or Bosch , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double-Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment - Spark Plug Testers, Or Equivalent International Standards Preferably Tapariya Or Bosch , Portable Fuel And Vacuum Gauge Tester Kit For Testing Fuel Pump Pressure, Fuel Pump Vacuum, Carburettor Intake, And Manifold Vacuum Systems In Petrol Engines With Dual Gauges - A Pressure Gauge Ranging From 0 To 10 Psi (0-0.7 Kg/Cm²) And A Vacuum Gauge Ranging From 0 To 28 In-Hg (0-70 Cm-Hg) - For Accurate Measurement Of Engine Fuel And Air System Performance, With Standard Automotive Fittings For Quick Connection To Various Fuel And Vacuum Lines And Conforming To Is 1446: Automotive Test Equipment - Pressure And Vacuum Gauges Or Equivalent International Standards Like Sae J1812 For Fuel System Testing Instruments.Preferably Tapariya Or Bosch , Petrol Engine Compression Tester Kit (400 Mm) Including Threaded Adaptors In Sizes M10, M12, M14, And M18, Along With Two Rubber Cone Ends For Both Threaded And Non-Threaded Testing, Equipped With Straight And Angled Push-On Connectors And A 400 Mm Flexible Hose, To Diagnose Issues Related To Piston Rings, Valves, Or Head Gaskets, Suitable For Cars, Motorcycles, And Small Petrol Engines.Preferably Tapariya Or Bosch , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel Preferably Tapariya Or Bosch , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220-230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 Preferably Tapariya Or Bosch , Soldering Station Operating On A 220-240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices .Preferably Tapariya Or Bosch , Compact, Durable, And Easy To Operate Portable High-Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections.Preferably Tapariya Or Bosch , Double Piston Lever Grease Gun Delivering Up To 2.4 Grams Of Grease Per Stroke, Pressures Up To 6000 Psi, With A Double-Piston Mechanism, Compact And Lightweight (Approx. 2 Kg).Preferably Tapariya Or Bosch , Durable And Easy-To-Use Steel Lubrication Oil Dispenser Can For Smooth And Controlled Lubrication With A 500 Ml Capacity, Made From High-Quality Steel With A Powder-Coated Finish, The Can Is Lightweight (Approx. 200 G), Waterproof, And Ergonomically Designed For Comfortable Handling And Precise Oil Flow. Preferably Tapariya Or Bosch , Part 5- Power Tools & Equipments , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12-M22) And High-Strength Bolts (M12-M16) In Vehicle And Machinery Maintenance Applications Preferably Makita Or Bosch , Heavy-Duty Angle Grinder, Of Reputed Make, Single Phase 220-240 V, 50/60 Hz Ac Supply, Input Power 2200 W No-Load Speed 8500 Rpm To Use With 180 Mm (7) Diameter Abrasive Wheels, And Equipped With Side Handle, Wheel Guard, And Spindle Lock A 2.0 M Power Supply Cord And Conforming To Is 7554 / Iec 60745-2-3 / Iso 11148-7 Or Equivalent Standards (Low Vibration Level (=6.5 M/S²), Sound Pressure Level Not Exceeding 91 Db(A)). Preferably Makita Or Bosch , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual.Preferably Makita Or Bosch , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350-550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. Preferably Makita Or Bosch , Portable Air Compressor, Of Reputed Make, Single Phase 230 V, 50 Hz Ac Supply, Fitted With An Electric Motor Of 2.0 Hp (1.5 Kw) A Maximum Working Pressure Of 8 Bar, Free Air Delivery Not Less Than 200 Lpm (7.2 Cfm), And A Motor Speed Of 2850 Rpm. Air Receiver Tank Of 50 Liters Capacity, Conforming To Is 5456 / Is 2825 Standards And The Compressor Shall Conform To Is 10437 / Iso 1217, And Fitted With Pressure Gauge, Safety Valve, Drain Valve, And Automatic Pressure Switch. The Complete Unit Shall Be Portable, Vibration-Damped, And Equipped With Wheels And Handle For Easy Movement. Preferably Makita Or Bosch , Single Phase Annual Rate Contract Welding Machine Of Reputed Make, With Inverter-Based Igbt Technology To Be Operated On Ac 220V ±15%, 50/60 Hz Single Phase Supply And Deliver A Welding Output Current Up To 400 Annual Periodical Maintenance With A Duty Cycle Of Not Less Than 60%, An Efficiency Of Minimum 80% And Power Factor Not Less Than 0.73, With Insulation Class F And Protection Grade Ip21 As Per Is 2879 / Is 3024 Or Equivalent International Standards. And Necessary Accessories Such As Welding Cable, Electrode Holder, And Earth Clamp Etc. Should Be Included.Preferably Makita Or Bosch , Bench Grinder, Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply Equipped With A 350 W Induction Motor Of 2950 Rpm. Two 200 Mm Diameter Grinding Wheels Each Provided With Eye Shields And Wheel Guards, Heavy-Duty Aluminum Base With Tool Rest, Tool Storage Box, And Safety Accessories Etc. Complete Conforming To Is 302 / Is 6932 / Iec 61029 Or Equivalent.Preferably Makita Or Bosch , Bench Drill Press, Of Reputed Make, Single Phase 120 V Ac, 50/60 Hz Fitted With Electric Motor Of Approximately 1/3 Hp Rating, Manually Adjustable Work Table With Depth Stop For Accurate Drilling. Chuck Guard, Power Switch With Overload Protection, And Belt Or Gear-Driven Spindle System Conforming To Applicable Safety And Performance Standards Such As Is 2425 / Iso 16089 / Iec 61029 Or Equivalent Supplied Complete With Drill Chuck, Key, And Instruction Manual.Preferably Makita Or Bosch , Part -6 Furniture And General , Bench Vice Of Heavy-Duty Engineers Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard.Preferably Goderej Or Dewalt , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold-Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8-1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. Preferably Goderej Or Dewalt , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants.Preferably Goderej Or Dewalt , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 8 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants.Preferably Goderej Or Dewalt , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3-4 Ventilated Shelves With Acid-Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm.Preferably Goderej Or Dewalt , Rack For Lubricants Constructed From Treated Wood Or Plywood Frame With Raised-Edge Shelves To Contain Spills. Each Shelf Shall Carry At Least 100 Kg And Be Coated With Oil-Resistant Paint. Suitable For 1-20 L Containers. Approx. Size: 1800 Mm × 1200 Mm × 450 Mm.Preferably Goderej Or Dewalt , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3-5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm.Preferably Goderej Or Dewalt , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220-240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion-Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety.Preferably Goderej Or Dewalt , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle Preferably Goderej Or Dewalt , Part 7-Safety Tools , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression.Preferably Honeywell Or Karam , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1-3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask).Preferably Honeywell Or Karam , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592.Preferably Honeywell Or Karam , Emergency Safety Shower Shall Deliver A Minimum Of 75 L/Min At Operating Pressure Of 2-6 Bar, With Pull-Rod Activation And Stay-Open Valve Ss Stay Open Ball Valve With Push Plate, Material Of Construction Gi And Abs Plastic. Preferably Honeywell Or Karam , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865.Preferably Honeywell Or Karam , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules.Preferably Honeywell Or Karam , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields.Preferably Honeywell Or Karam , Ppe Industrial Gloves: For Mechanical Work-Leather Or Nitrile (Is 6994); For Chemical Work-Pvc/Neoprene (En 374); For Electrical Insulation-Rubber Class 0 (Is 4770).Preferably Honeywell Or Karam , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic.Preferably Honeywell Or Karam , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471.Preferably Honeywell Or Karam , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date.Preferably Honeywell Or Karam , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops.Preferably Honeywell Or Karam , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat-Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial Environments. The Pair Shall Be Supplied In Standard Size (Large/Universal Fit) And Shall Bear Proper Labeling Indicating Brand, Size, And Conformity To Relevant Standards.Preferably Honeywell Or Karam , Part 8 -Lifting And Hoisting , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme-Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use.Preferably Ravaglioli Or Atselgi , Floor-Mounted Electro-Hydraulic Two Post Lift Of 4,000 Kg Capacity With Symmetric Lifting Arms (Front And Rear Adjustable) And Double Hydraulic Cylinders, Made Of High-Strength Steel Columns With A Minimum Inside Column Clearance Of Approximately 2799 Mm And A Bay Width Of About 3419 Mm, Operates On Single-Phase Or Three-Phase Power Supply, 50 Hz Frequency, Power Rating Of Approximately 3.0 Hp. Full Height Achieved In Less Than 45 Seconds, With An Overall Height Around 2844 Mm Including Automatic Arm Locks, Mechanical Safety Latches, And Overload Protection Etc. All Conforming To Is/Iso 13849 Standards.Preferably Ravaglioli Or Atselgi , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 10 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti-Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service.Preferably Ravaglioli Or Atselgi
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
43.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
44.
Defence #9416178 AOC
Tender For Provision Of Oh Tanks Ug Sumps And External Services For Map Ph-Ii Under Ge S Pune And Ge N Pune.; 1 SCH A PART-I TO VII:Note: These schedules are pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structure) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch A Part-IV (Sewage Disposal) 6 Total amount of Sch A Part-V (External Water Supply) 7 Total amount of Sch A Part-VI (External Electric Supply) 8 Total amount of Sch A Part-VII ( LIGHTNING PROTECTION ) 9 Total amount of Sch A Part-VIII (Excavation and Earthwork) 10 SCHEDULE A PART-IX (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only. 11 MISC ITEMS E/M WORKS OF INTERNAL & EXTERNALELECTRICAL SUPPLY 12 S&FLEDstreet light luminaire 25 W with pressure die castaluminium housing LED street light luminaries with IP66 with 25 W high power LED, maintenance free system and connecting up with cable, including 1.5 m long GI bracket of required dia, bent to shape, clamp and nut bolts of suitabler size complete all as specified and all as directed. 13 S&F solar powered aviation obstructionlamp complete sysytem make: Altos model AOL-Q-3 SP or equivalent model in philips / Crompton Greaves / bajaj consisting of : (a)LED based avitation obstruction lamp fitting (b) solar panel (c)Battery unit (d) Mounting structure for all above with inter connecting wiring complete all as specified and ditected. 14 Testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 100 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV, 3 PH, LT-433 Vand making compete connection of HT and LT Sidewith glands, lugs complete all as specified and directed.(Note- Transformer already installed /mounted on platform at site , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item. 15 All as per item No- 11.003above but capacity22 KV 200 KVA. 16 Installation, testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 300 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV,LT-433 V and making connection on HT & LT side with gland and lugs , The transformer will mount on platform as per manufacturer instruction 0r Typical drawing or of size of size 2.00 M x 2.00 M x 3.50 M deep (1.00 m below GL) withPCC (1:3:6) type C2 and15 cm thick RCC (1:2:4) type B1 for top, reinforced with 10 mm dia TMT bars @ 150 mm C/C complete including excavation & earthwork in any type of strata viz soft/loose/hard/dense/Rock, frame work all as specified and directed(Note- Transformer shall be issued under Sch B free for fixing , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item.The rate quoted by the contractor shall deemed to be included the cost offoundationa and transportation of transformer from MES yard to work site.No extra payment shall be made on this account.) 17 All as per item No- 11.005above but capacity 11 KV100 KVA. 18 All as per item No- 11.005 above but capacity 22 KV 400 KVA. 19 Servicing of existing LT electrical distribution/control panel of any size and capacity including cleaning of dust and debris, tightening of all connections, checking of contactors/relays, testing of insulation resistance, repair/replacement of defective control wiring (upto 1.5 sqmm copper) and faulty indicators (LED type), Testing and replacement of defective control MCBs upto 63A andensuring full operational status. Complete in all respects as per standard practice and directed by engineer-in-charge 20 Supply, jointing and testing outdoor cable end termination joint (heat shrinkable) suitable for 3 core 185 sqmm 22 KV XLPE cable suitable for earth system complete all as specified and directed. 21 Supply & fix heat shrinkable straight through joint 22 KV XLPE cable suitable for earth system of size 185 sqmm 3 core complete all as specified and directed. 22 M&L Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge or the plate at a depth of not less than 1.5 m below ground level, connected to and including galvanised eath strip 32 mm x 6 mm by means of bolts,nuts and check nuts and washers of galvanised steel. Gl pipe 40 mm dia light grade pipe for protection of G.l. earth strip both to be provided to the extent of 7.5 meters as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per elctrical plate No. 3 of SSR Part 1·2009 including PCC chamber made up of PCC 1:3 :6 type C1 & RCC Chamer cover of size 540x540x100 mm made with 1:2:4 Type B1 using 6 mm round MS bar & 8 mm MS bar for handle , 20 mm dia medium grade G.I. Watering pipe from top edge of the earth plate upto M.S funnel with wire mesh provided inside the concrete earth pit for watering arrangement including excavation and earth work in any type of soil and testing complete all as specified and directed. 23 Installation testing and commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installation on cable trench housing cubicle Type, free standing Panel CPRI approved working on 440 V 3 phase 50 Hz, AC supply with aluminium bus bar suitable for 800 Amps fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted asper the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams GE/1668/901:(a) Volt meter 0 – 500 Volt with selector switch – 01 (b) Ammeter 0.1000 Amps with CTs and selector switch – 01. (c) Indication Lamp assembly – RYB LED – 01 set.Incomer : 630 A 4 pole, ACB-02 Nos. Bus coupler : 630 A 4 Pole, ACB -01 No. Outgoing feeders :3 Pole, 315 A MCCB, 50 KA -05 Nos, 4 Pole, 250 A MCCB,35 KA-03, 3 Pole, 200 A MCCB, 35 KA -02Nos, 4 Pole, 100 A MCCB, 25 KA-01 Nos. Panel fabrication & Bus bar for above feeders. (Note- LT Panel with components as above shall be issued under Sch B free for fixing ) 24 Installation, testing & commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installationon cable trench housing cubicle type, free standing, panel CPRI approved 3 phase, 50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per specifications and having the following details and as shown in single line diagrams GE/1968/901 : (Note- LT Panel with components as above shall be issued under Sch B free for fixing )Incomer:160A, 4 pole 25 KA, MCCB with S/C adjustable, O/L & E/F thermal magnetic releases - 01 eachOutgoing Feeders:160A, TP, 25 KA, 415 VoltMCCB withS/C & adj. O/L& E/F thermal magnetic releases - 05 Nos25 KVAR APFC Compartment80A, TPN, 25KA - 1 No, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic release 01 Each8 Stage APFC Relay16A, TPN, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 5 KVAR Capacitor) 01 Each32A, TP, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 10 KVAR Capacitor) - 02 NosCapacitor MD - XL 25 Installation testing and commissioning diesel engine/driven generating set of capacity 30 KVA (24 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories :(Note- DG Setwith components as above shall be issued under Sch B free for fixing ) (a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling 26 (f) Toggles switch for idle running(g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 30 KVA/24 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 MAKE: Kirloskar C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 30 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 27 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS: (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 30 KVA DG Set per CPCB Norms 28 Installation testing and Commissioning of INDOOR TYPE ENCLOSURE with angle iron pedestal frame & including steel structure required for installation on cable trench housing cubicle type, free standing, panel CPRI Approved working on 440 V, 3 Phase50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams Ge/1968/905 (Note- LT Panel with components as above shall be issued under Sch B free for fixing )INCOMERFP pole MCCB 250 Amps 35 KA – 02 NosOut Going feeders:TPN pole 16A MCCB, 25 KA – 02 NosTPN pole 20A MCCB, 25 KA – 02 NosTPN pole 63A MCCB, 25 KA – 02 NosTPN pole 100A MCCB, 25 KA – 02 NosTPN pole 125A MCCB, 30 KA – 02 Nos3 KVAR capacitor duty contractor – 02 Nos5 KVAR capacitor duty contractor -02 Nos20 KVAR capacitor duty contractor -02 Nos30 KVAR capacitor duty contractor -02 Nos40 KVAR capacitor duty contractor -02 Nos8 stage APFC relay – 02Nos 29 Installation testing and commissioning diesel engine/driven generating set of capacity 160 KVA (128 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories : (Note- DG Set with components as above shall be issued under Sch B free for fixing ) complete all as specified and directed.(a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling(f) Toggles switch for idle running 30 (g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 160 KVA/128 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 160 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 31 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS:(i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.(E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 160 KVA DG Set per CPCB Norms 32 Installationtesting & commissioning of indoor cubic type, free standing floor mounted including of steel structure required for installation on cable trench with base frame, AMF panel CPRI approved on 440 V 3 phase 50 HZ, AC supply. It shall be extendible at both ends, with aluminium bus bars 200 amps capacity fully compartmentalized dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank procress & suitable for IP-52 protection, as per section and having the following details and as shown in single line diagrams GE/1968/094 , complete all as specified and directed.( Note - AMF panel with components shall be issued under Sch B free for fixing ).Incomer100A 4 pole, 25 KA motorized MCCB – 01 NoOutgoingTPN 63 A MCCB, 25 KA – 02 NoTPN 32 A MCCB, 25 KA, 32 A MCCB, 25 KA – 2 NoPanel Fabrication & Busbar for above feeder 33 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 315 A MCCB,50 KA- 01 NoOutgoingTPN 63A MCCB, 25 KA – 08 NosPanel Fabrication & Busbar for above feeder 34 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 250 A MCCB,35 KA- 01 NoOutgoingTPN 63A MCCB, 35 KA – 08 NosPanel Fabrication & Busbar for above feeder 35 Supply, Install, testing, and commissioning of outdoor type, enclosure double door with angle iron pedestal frame & including steel structure required for installation on cable trenches, housing cubical type free standing,panel working on 440 volts, 3 phase 50 hz, AC supply with aluminium bus bar,full compartmentalised dust proof and vermin proof 3.15 thcik CRCA sheets steel enclosure, painted as per the 7-tank process & suitable as per IP-56 protection as per specification and having the following details and as shown in single line diagrams GE/1968/901 (Panel for 3 Alexander Road) complete all as specified and directed.a)MCCB 160 amps 4 pole, 25 KAbreaking capacity with short circuit adjustable overload& earth fault thermal magnetic release-8 Nos, CTs, ammeter with selector switch, voltmeterwith selector switch(Incomer)-01 Nos Bus bars: 250 A TPN aluminium Busbars suitable for 25kA for 1 Sec Outgoing Feeders :a) MCB TP 40 Amps 25 KA breaking capacity with short circuit adj overload and B/F thermal magnetic releaseb) Suitable enclose IE panel fabrication and bus bars for above MCB feeders. c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job 36 Supply, installation, testing and commissioning of readymade 08 way TPN DB metal doorwith 200A rated busbar with following (CAT Part NoDBTPN008DDS of L& T or equivalent in Siemens/Legrand/C&S)Incomer: (a) MCB 4 Pole 60 Amps, 415 Volts breaking capacity 10kA 02 Nos (BB30630C of L &T)Outgoing feeders:(a) MCB TP 25 Amps, 415 Volts breaking capacity 10kA 04 Nos (BB30250C of L &T)(b)MCB SP 10 Amps, 230 Volts breaking capacity 10KA 04 Nos (BB10100C of L &T) 37 Supply, installation, testing and commissioning of outdoor line up of 11 KV RMU type compact panels, consisting of following :-11 KV 630 Amps 20KA for 3 sec. air/gas insulated RMU panel with 1 No incommingmanullay operated VCB and 02 Nos outgoing load break switches,CTs for protection as per detils given in specification complete in all respect inverse time over, current, short circuit & earth fault with instantaneous elements relay.Indication : ON, Off, Trip, R.Y.B. with facility for transformer buchholz relay trip with terminals for 230V AC supply aluminium Busbars 630 Amps, 11KV, TP busbars for 20 KA for 1 sec with PCC foundation all as per required & as per manufacturer instructions. complete all as specified and directed. 38 Supply, installation, testing and commissioning of 11KV 50/5 Amps ratio oil immersed vacume impragnated single phase current transformer with VA burden of 15 for class 0.5 class SP 10 with 25 KA short circuit rating for 1 second complete with all structure base and mounting arrangement as indicated and also as per specification and technical particulars. 39 Supply,Installation , testing and commissioning of outdoor line-up of 22 KV RMU type compact panels, consisting of : 22 KV 630A, 20KA for3 sec Air/Gas insulated RMU panel with 1 No Incomer & 2 Nos outgoing: 22 kV, 16 kA for 1 second, 630A HT VCB with 3 nos. resin cast 22000V/ sqrt. 3/ 110V/ sqrt. 3 withdraw-able PTs, HT and LT fuses ffor PTs, In comer 3 nos 50/1A & in outgoing 9 Nos. 20/1A CTs-core-1: class 0.5 CTs for metering, Core 2 : class 5 P10 for protection, inverse time over current, short circuit & each fault with intantenous elements relay, master trip, R.Y.B spring charge, trip circuit healthy. ON-OFF Push buttons illumination lamp, hooter, industrial socket with switch, space heater with thermostat, control MCB & control terminals etc complete all as specified and directed. 40 Laying only in trenches or fixing on wall or pole LT XLPE UG cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (Heavy duty) with standard aluminium conductor 1100 volt grade of the follwing size including provision of necessyar lugs and glands as under : (Note- LT under ground cablementioned below at sl No (a) to (i) shall be issued under Sch Bfor laying/fixing ) 41 a) 300 sqmm 3.5 core 42 b) 240 Sqmm 3.5 core 43 c) 185 sqmm 3.5 core 44 d) 150 Sqmm 3.5 core 45 e) 120 Sqmm 3.5 Core 46 f) 50 Sqmm 3.5 Core 47 g) 35 Sqmm 3.5 core 48 h) 25 Sqmm 4 core 49 i)16 Sqmm 4 core 50 Supply and fixing and installation of fire extinguisher CO2 Map cap of 4.5 Kg as per IS 2878 Complete all as specified andas directed. 51 MS fire bucket 13 Ltr Cap of fire approved quality painted red filled with sand Complete all as specified andas directed. 52 Supply only hand gloves for safety,suitable for 22 KV grade. Complete all as specified andas directed. 53 Supply only hand gloves for safety,suitable for 11 KV grade. Complete all as specified andas directed. 54 MS padestal stand duly painted for suspending fire buckets 55 M&Lfor shock treatment chart in different languages (english, Hindi, Marathi) 56 Supply and placing of first aid box as per specification 57 Cable route marker made of galvanised iron supporting with GI angle for HT/LT cable root marking 58 M&L for Road cuttingby core cutting machine not less than 0.6 mtr wide and .45 mtr depthfor laying RCC and GI Pipe for the the HT/LT cable and making good surface with PCC 1:4:8 type D-2 using 40 mm graded stone aggergatecomplete all as specified and directed. 59 Supply and erect steel tubular poles swaged welded poles complete for two pole structure with MS base plate, MS pole cap, bolts nuts, and screws as per IS 2723 ( part II ) 1980 made out MS tyubing duly painted with metal primer and two coats of aluminium paint over exposed surface and Making 4 Nos of strips of 30 cm wide in alternate black and yellow colourup to 1.5 mtr hight, Writing pole number and voltage level encompassed by circle of suitable diausing two coats of synthetic enamel paint over a coat of red oxide zinc chrome primerbottomand one coat of red oxide and two coats of bituminous paint for embedded portion as specified type 410 SP - 31 of 9 mtrs long complete all as specified and as directed. ( Note- Excavation / earth work , PCC will be measured and paid separately ) 60 S&F FRP box,MCB SP 6 Amp-01 No and clamps made out of FI 32x6mm and GI nut bolts. Complete all as specified andas directed. make-syntex Model GSJB-3020 with 4 connectors or eqvt 61 S&Ftimer switch box fabricatedout of 16 SWG CRCA sheet with mounting arrangement duly powder coated consisting of the following :-a) Timmer astronomical-1, b) Power contactor 63 Amps make- -01 Noc) connector 100 Amps 230 Volts - 03 Nosd) MCB TPN 63 Amps 415 V - 01 Noe) Control fuse 2 Amps -01 NoComplete all as specified andas directed. 62 S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for suitable for 22 KV working pressure. Complete all as specified andas directed. 63 S&F Disc type porcelain, vitreous, white, brown or green i nsulator includingone galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 145 mm height, 255 mm dia ball and socket type Two-in-assembly for tension with tension clamps for conductor suitable for 22 KV working pressure. Complete all as specified andas directed. 64 Supply and lay rubber mat 2 mtr x 1 mtr,10mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 65 Supply and lay rubber mat 2mtr x 1 mtr,30mm thick 22 KV grade AC elect supply. Complete all as specified andas directed. 66 Supply and lay rubber mat 2mtr x 1 mtr, 19mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 67 Supply, jointing and testing Outdoor type cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 68 Supply, jointing and testing Outdoor type cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 69 Supply, jointing and testing indoor typeCable jointing kit for 11 KV (Earthed)grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size ofsize 150 sqmm 70 M & L for discharge rod PVC coated suitable for 22KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 71 M & L for discharge rod PVC coated suitable for 11KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 72 Supply onlyEngine oil, multi grade premium Genuine oil 15W40 as per manufacturer recommendations in DG sets complete all as specified.Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 73 Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 74 Supply and fill for genuine coolant in 5 litres plastic sealed containerfor topping up in Radiator of DG set located at different locations complete all as specified and as directed. 75 Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed. 76 Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed. 77 Maintenance and servicing for Comprehensive C Check maintenance service for DG Set of capacity 160 KVAincluding dismantling, cleaning, filter & oil replacement, fuel system overhauling, radiator inspection, valve clearance adjustment, load testing, FIP Caliberation, checking and repair of radiator for leakage,and detailed service report submission as per OEM recommendation to DG setincluding replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 100 KVA DG set installed at Southern Command Signal Centrecomplete all as directed by Engr- in- Charge.Note:- (i)Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii)The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v)Work shall be carried out at site at different location Work to be carried out by OEM certified technician or approved equivalent. Service reports to be submitted post-maintenance 78 All as per item no. 11.066here-in-above but of capacity 100 KVA. 79 All as per item no. 11.066here-in-above but of capacity 30 KVA. 80 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 160 KVA. compete all as specified and as directed. 81 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 100 KVA. compete all as specified and as directed. 82 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 30 KVA compete all as specified and as directed. 83 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 160 KVA compete all as specified and as directed. 84 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 100 KVA compete all as specified and as directed. 85 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 30 KVA compete all as specified and as directed. 86 S & F air filter element suitable for capacities ofD. G . Set 160 KVAcompete all as specified and as directed. 87 S & F air filter element suitable for capacities ofD. G . Set 100 KVAcompete all as specified and as directed. 88 S & Fair filter element suitable for capacities ofD. G . Set 30 KVAcompete all as specified and as directed. 89 S & F by-pass filter element with O ring suitable for 160KVA DG set compete all as specified and as directed. 90 S & F by-pass filter element with O ring suitable for 100KVA DG set compete all as specified and as directed. 91 S & F by-pass filter element with O ring suitable for 30KVA DG set compete all as specified and as directed. 92 S & Ffan beltcomplete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 93 S & F belt for battery charging alternator complete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 94 S & F rubber hose pipe set for water circuit with clamps complete suitable for 100KVA DG set complete all as specified. 95 M & L for carrying out repairs to AMF panel of 100 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measuredand paid seperately under relevant items. 96 S & Ffor digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent. 97 S & Ffor digital type Ammeter 0-200 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent 98 S & Ffor digital type Voltmeter 0-500 Volts 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent. 99 S & F for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified. Make: Rishab/ L&T/AE/ Legrand or equivalent 100 S & F for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron. 101 S & F for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol 102 Supply and fix for lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and as directedMake- Exide/Amaron. 103 Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacementup to desired level of transformer oil capacity and Oil circuit brekar complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] 104 Supply only breather assembly as per existing size, shape and specification complete for capacity 315 KVA , 11/0.433 Voltstransformers including fresh blue silica gel 105 Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of snthetic enamel paintby spray paint incl writing SM No/MES No , capacity of transformer of 315KVA capacity all as directed by Engr-in-Charge 106 Supply and fix for switch air break gang operated HT 11 KV Volt grade out door type, triple poleof capacity 200 amps rating mounted on Polymer based 09 insulator with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame horizontally mechanicallyoperated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed. (Universal/Pactil) 107 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulatorswith steel frame 200 Amps capacity, siutable for 11KV, HT system,out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed. Make : Universal/National or its equivalant.Note for Item No 11.094 & 11.095 : The work to be carried out in existing structure. Hence continues shut down will not be available. According to the availabity of shut down timing the contractor shall manage the work in quoated rate only. 108 M&L for Painting of HTpoles including cross arms complete with synthetic enamel paint including filling cavities with filler one coat after cleaning all dust/rust including writing the pole No. and all as directed by Engr-in-Charge 109 M & L for Servicing of Molded Case Circuit Breakers (MCCBs)/ACB in existing panelsincluding cleaning, tightening of connections, checking of mechanical operation, insulation resistance testing, functional testing, lubrication of moving parts, and recording of test results. All tools, materials, labor, and consumables to be included for following capacity:- 110 630 Amps ACB 4 pole,415 volt manual drawout type with micro processor release 111 3 Pole 350A MCCB, 36 kA 112 3 Pole 250A MCCB, 36 kA 113 3 Pole 160A MCCB, 36 kA 114 3 Pole 125A MCCB, 36 kA 115 3 Pole 100A MCCB, 36 kA 116 3 Pole 63A MCCB, 36 kA 117 3 Pole 32A MCCB, 16 kA 118 S & F in repairs ACB 4 Pole, current rating 630 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of(Make : L & T Cat No CM96111OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as directed. 119 S & F for 4 pole MCCB400 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 120 S & F for4 pole MCCB 250 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 121 S & F for4 pole MCCB 200 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 122 S & F for 4 pole MCCB 160 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand/ Schenedier)complete all as specified and as directed. 123 S & F for 4 pole MCCB 100 /125 A, having breaking capacity 36 kA (Make :L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 124 S & F for 4 pole MCCB 63 A, having breaking capacity 10 kA, (Make : L & Tor equivalent in Legrand / Scheneider) complete all as specified and as directed. 125 M&Lfor switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and MS galvanized steel frame with operating mechnizing worked from ground level including operating rod of size 32 mm dia / 25 mm dia as reqd GI medium grade for current rating upto 200 Amps 22000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified complete all as specified and as directed. 126 S&F for drop out fuse assy single pole 22KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures complete all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 127 S&F fordrop out fuse assy single pole 11KV , 25 Amps rating complete expulsion fuse element mounted on four / two pole structuresincluding dismanteling old existing UNSV all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 128 S&F for pin type insulator, HT Polymer/porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 22000 volts including dismantling insulator any type / any sizecomplete all as specified and as directed. 129 S&F for insulator disc type single disc assembly, ISI marked working pressure 22000 volts, porcelain vitreous white, brown, or green size 145 mm high and 255 mm dia ball and socket with tension clamp to suit the size of conductor (ACSR)including dismantling insulator any type / any size complete all as specified and directed. 130 M&L for aluminium strip 25 x 4 mm of required lengthwith color sleeves for jumpering purpose in 11 /22 KV DP/FPincluding taking down existing aluminium conductor etc complete all as per the direction of Engineer-in-charge. 131 S & Ffor gasket set of 22/11 KV 100 KVA to 400 KVA transformer complete all as specified and directed. 132 S& F for silicagel breather complete all as specified and directed. 133 M&L for Testing of exisiting earthing resistance with suitable digital Earth tester complete all as specified and directed 134 S&Fepoxy based insulator with screw, nuts and bolts fixed on OH reservior roof top and on shaft surfaces not more than 2.00 m apart from fixing aluminium or GI strip complete with fixing arragnment complete all as specified and directed. 135 Supply, laying,testing and commissioning or passing through pipe,XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area of size 3 core 150 Sqmm 136 Laying in trenches and testing cable XLPE insulated screen PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 22000 volts grade of size 3 core X 185 sq mm suitable for earthed system etc complete.(Note-HTcablewill be issued under Sch B free for fixing/laying). 137 Supply, installation and testing complete electronic digital type water level indicator devicesuitable for operating at 230V +/- 10%, 50 Hz sysytem having 150mm size digital display and alarm at low/high level of OHT / sump.The complete unit fitted in MS sheet base in two boxes, one box to be installes at sump/OHR and second at pump house bothunit to be connected with flrxible copper cable of .5 sqmm 8 pair and length from sensor to pump house building or OH reservoirs of 21 mtr and 15 mtr staging,All enclosed in sheet metal enclosures of 02mm thick with hinged door and locking arrangement and support GI wire/PVC pipe etc properly laid or fixed on wall / surface all as directed by Eingr-in-charge.Make- SECO type DDS-6 or equivalent model in Schneider/ Havels/ L&T. 138 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 40 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 139 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 50 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 140 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 75 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 141 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 90 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 142 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 110 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 143 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 120 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 144 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 160 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 145 MISC ITEMS OFEXTERNAL WATER SUPPLY 146 Laying and testing ductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 150 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 150mm bore will be issued under Sch B for fixing only. (Rates of DI fitting required for sch B items will be included in the quoted rates) 147 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 200 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 200mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 148 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 100 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 100mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 149 Supply, fix and testing dual type non return valve of 100 mm bore, cast iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent IS. Complete all as specified andas directed. 150 Supply, fix andtesting gun metal dual type non return valve of25mm bore,iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent ISComplete all as specified andas directed. 151 M& L for DI fittings & specials such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end taperingbellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for run lead joints ofsize from 80 to 200 mm bore. Complete all as specified andas directed. 152 Supply, fix and testing GM gate/globe valves heavy duty conforming to IS 778 with iron wheel head screwed both ends suitable forfollowing sizes ofbore:-Complete all as specified andas directed. 153 25 mm bore 154 40 mm bore 155 50mm bore 156 80 mm bore 157 Install,testingand commissioning of LT distribution outdoor typepanel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 3.15 mm thick with MS angle iron of size 50x50x6 mmto be mounted on floor / wall suitable to accommodate common bus bar and the following accessories:(a) MCCB TPN 100 Amp 25 KA 415 Volt thermal adjustable- 1 No. (b) Copper bus bar 400 Amps. 4 runs duly coloured PVC sleeve (c) Fully automatic star delta starter suitable for 7.5 HP pump set 440 V Model MK-1 Make L and T with electric connection - 02 No. (d) MCCB TP 10 KA 63 Amp - 02 N os (e) MCB DP 32 Amps - 02 Amps(f) Ammete 0-200 amps with CT & selector switch - 01 No (g) Voltmeter 0-500 V with selector switch - 01 No(h) lndiating lamp - LED type RYB ) Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 158 Install test and commissioning of LT distribution panel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 Wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 2 mm thick with MS angle iron of size 50x50x6 mm to be mounted on floor / wall suitable to accommodate common bus bar and the following accessories :- (a) MCCB TPN 63 Amp 25 KV 415 Volt - 1 No.(b) Copper bus bar 400 amp - 4 runs duly coloured PVC sleeve (c) DOL starter suitable for 3.0 HP pump set 440 V Model MK-1 make L&T with electric connection :- 2 No. (d) MCCB TP 40 Amp 10 KA 415 Volt-2 No (e) MCB DP32 Amp - 2 No.(f) Ammeter 0-100 Amp with CT and selector switches – 1 No(g) voltmeter 0-500 V with selector switch 01 No (h) Indicating lamp LED type RYB – 01 Set.Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 159 Install, Test, Commissioning of open well submersible pump set 80x80mm for pumping clear water at ambient temperature from UG sump for delivering 25 m3/hours at a total head of 40 mtr complete with suitable electric motor 7.5 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 80 mm dia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection.Complete all as specified andas directed. ( Note- submersible pump setshall be issued under Sch B free for fixing ) 160 Install, Test, commissioning of open well submersible pump set 25x25 mm for pumping clear water at ambient temperature from UG sump for delivering 165 LPM at a total head of 25 mtr complete with suitable electric motor 3.0 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 50 mmdia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection .Complete all as specified andas directed.( Note- submersible pump set shall be issued under Sch B free for fixing ) 161 Installation, testing and commissioning of 750 LPM capacity head105 M end suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 ± 10% 50 Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller includsive of suitable star delta starter inclding cable from starter to motor drawn through flexible metallic conduit pipe starter and suitable PCC foundation etc complete as per manufacturers recommendation. Complete all as specified andas directed. ( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 162 Installation, testingend suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 Volt + 10%, 50Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller inclusive of suitable star delta starter inlcuding cable from starter to motor drawn through flexible metallic conduit pipe following capacity inclusive of starter and PCC suitable foundation as per manufacturers recommendations. Capacity 1460 LPM, Head-100M. Complete all as specified andas directed.( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 163 Supply,install,testing & commissioning of end suction type centrifugal pump set, multistage,bronze impellor,water supply, assembled and tested for rated efficiancy complete with energy efficient motor conforming to IS 12615 common base frame,coupling guard and mechanical seal suitable for operation on 415 volts+/- 10%, 50HZ AC supply of capacity 1500 RPM, 700 LPM, head 70mtr inclusive of PCC foundation ,suction & discharge of pipes as per manufactures instruction.Complete all as specified andas directed.Note:- Cost of suction and discharge pipes upto 7.50 RM long each shall be deemed to be included in the rate quoted. 164 Supply installation,commissioning and testing ofDOSING SYSTEM ( MODEL: ADS-I of ALTOCH) consisting of 40 liter - 100 liter PE/FRP LID & leval gauge along with agitator with shaft and blade in plastic. mounted on tank Complete all as specified andas directed.. (Make : ALTOCH or Equvivalent as approved by Accepting officer) 165 S&F Cast iron body foot valve of size 150 mm bore flanged as per IS 4038 , including nuts, bolts, washers and rubber gaskets, complete all as specified & as directed. 166 Supply installation,commissioning and testing ofdosing pump model 96NGQ51 of Decrain,high presser single head gear motored adjustable dosing pump of following specification:-.(a) Adjustable high presser -0 to 100 PSI (b) Power-230v, 50HZ (c) RPM-44(d) HP 1/10 fractional(e) Out put -2 U.S GPD to 40 USGPDComplete all as specified andas directed.(Make : Decrainor Equvivalent as approved by Accepting officer) 167 S & F Cast iron air release valves with two air outlets of 50mm bore and fixing of cast iron pipe including necessary fittings. Complete all as specified andas directed. 168 Supply,Laying and jointing & testing DI pipe with socket & spigot ends, class K 7 with cement morter lining in side the pipe and zinc coatedout side asper IS 18329/2000 in standard length suitable for push onwith rubber gasket joints(tyton joints) laidintrenchesof size 150 mm bore. Complete all as specified andas directed. 169 Supply, laying, jointing and testing Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9 conforming to IS-8329of following sizes, in any length, laid in trenches/ pipe supports etc, pressure testing after laying complete a per IS-12288 including styrene butadiene rubber gasket joints, complete all as specified and as directed.NOTE: Tyton joints required are deemed to be included in the unit rate quoted. 170 100 mm bore pipe 171 200 mm bore pipe 172 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne 60 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set 173 (f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set(h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 174 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne39 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set(f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set 175 (h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 176 MISC ITEMS B/RWORKS 177 S&F factory made Steel fibre reinforced manhole frame and cover 100mm thick of size 1.20m x 0.60m complete all as specified and directed. 178 M & L for recharging of normal earth pits by excavating the earth at a radius of 600mm from the centre from the earth pit and at a depth of 900mm after removing the earth chambers and accessories carefully and keeping aside for reuse including adding and spreading chemicals as given below in 75mm layers each as ground level and watering, refixing the earth chambers and accessories after allowing the soil to settle down complete all as specified and directed by Engr-in charge.(a) Charcoal 10 kg. (b) Salt 10KgNote :- Excavation , refillingis included in quoated rate 179 Supply and fix for repairs earth chambers by demolishing unserviceable earth chambers and fixing new chambers ofPCC 1:3:6 type C1bed and chamber RCC 1:2:4 type B1of size (600X600X200)mm and thickness 120 mm andand CI cover 10mm thick hinged to CIframe duly groted with PCC, complete all as specified and directed. 180 Construction of valve chamber with PCC solid block masonry grade C-5, 200mm thick having 150mm thick hard core and PCC (1:4:8) type D-2 (using 40mm graded stone aggregate in foundation, including excavation & earth work in any type of soil, internal & external plaster to walls in cement morter 1:6, 15mm thick complete all asspecified and shownon drg No CEPZ/93/TD/20M Sht No 1/1 of following internal dimension:- 181 0.60mtr x 0.60mtr x 0.60mtr 182 1mtr x1mtr x1mtr 183 1.2mtr x1.2mtr x1.2mtr 184 Cutting the existing water line 300 mm dia for inserting Tee Reducer bend, coller etc complete ( Note : CI specials, lead joints excavation and earth work shall be measured and paid separately under relevant item of this schedule ) 185 Moblization of necessary equipment & manpower at site of work to carry out plate load test for determination of K Value (Modules of subgrade reaction) of Soil in the field in accordance to IS 9214-1979, complete in all respect, as specified & directed with & including following operations.(a) Digging out Pit of desired size & depth.(b) Placing & arranging Poclain, as per requirement & recording the settlement data with 03 Nos of dial Gauge in Horizontal Plain Placed at 120 degree, using Hydraulic Jack with proving ring & dial gauze of least count 0.002 mm & submission of report in sixtulicate determining modulus of subgrade reaction K Value.
Contract Date: Feb 06, 2026 Contract Value : 8.36 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
Maharashtra View Result →
45.
Drinking Water Supply and Sanitation #9410938 AOC
Tender For Reconstruction Of Anandhacauvery Head Sluice At Rb Of Vennar At Ls 36.260Km & Anandhacauvery Syphonat Katchamangalam Village Of Budhalur Taluk In Thanjavur District.; 1 Dismantling clearing away and carefully stacking materials useful for reuse for any thickness of walls of Brick or stone masonry in cement mortarunder 3m heightetc., complete complying with standard specification andas directed by the departmental officers. 2 Dismantling clearing away and carefully stacking materials useful for re-use for any thickness of Plain Cement Concrete etc.,complete complying with standard specification and as directed by the departmental officers. 3 Earth work excavating for foundation in all kinds of soils and sub soils and depositing on bank with initial lead of 10 m and initial lift of 2 m except hard rock requiring blasting to full depth as may be directed inclusive of shoring strutting, bailing out water wherever necessary and refilling the sides of foundation with excavated earth as per standard specification and as directed by the departmental officers. 4 Earth work open excavating forfoundation in all kinds of soils and sub soils and depositing on bank with initial lead of 10 m and initial lift of 2m except hard rock requiring blasting to full depth as may be directed inclusive of shoring strutting, bailing out water wherever necessary and refilling the sides of foundation with excavated earth as per standard specification and as directed by the departmental officers. 5 Earth work excavating and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel, stoney earth and earth mixed with small size boulders etc.,complete complying with standard specifications and as directed by the departmental officers. 6 Supplying and filling with M.sand for foundation and basement in layers of not more than 15 cm thick including watering, consolidation etc., complete complying with standard specification and as directed by the departmental officers. 7 Providing and placing Plain Cement Concrete M10 grade using crusher broken hard granite course aggregate (well graded) of nominal maximum size of 40mm to I.S specified grading (To achieve the specified characteristic strength of 10N/mm2 in 28 days) and mixing the ingredients in approved mixer including dewatering of the placement site by baling / pumping and diverting wherever necessary placing in layers and vibrating, water curing, finishing the surface with all leads and lifts etc., complete complying with standard specification and as directed by the departmental officers. 8 Providing and placing Plain Cement Concrete M15 grade using crusher broken hard granite course aggregate (well graded) of nominal maximum size of 20mm down graded to I.S specified grading (To achieve the specified characteristic strength of 15N/mm2 in 28 days) and mixing the ingredients in approved mixerof the placement site by baling / pumping and diverting wherever necessary placing in layers and vibrating, water curing, finishing the surface with all leads and lifts etc., complete in all respects so as to attain the profile and strength specified in the approved drawing and specifications, etc., complete complying with standard specification and as directed by the departmental officers. 9 ProvidingandlayinginpositionReadymixedPlain CementConcreteofM20using20mmsize downgraded (HBGS) hard broken granite stone jelly to attain the specified characteristic strength not less than 20N/mm2 at 28 days and manufactured in fully automaticbatchingplantandtransportedtositeof workintransmitmixerincludingpumpingRMCfrom transmit mixer for all leads, having continuous agitatedmixer,includingpumpingRMCfromtransitmixerto siteoflayingadmixturesinrecommended proportions as per IS 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in chargeincludingproductioncostofconcretebymixer plant including batching, mixing, hire charges for machineriessuchasbatchingplant,Generator,and carriage of concrete by transporting the concrete from batchingplantto thesitebyusingtransitmixer including charges for operator and helpers and pumping of concrete from site to the required location including hire charges of pump, piping work and accessories etc., labour for pouring, consolidating and etc., complete complying with standard specifications and as directed by the departmental officers. 10 Providingandlayinginposition,StandardisedConcrèteMix M-25Gradeinaccordancewith IS:456- 2000, using 20mm and down graded hard brokengranite stone jellyfor all RCC items of workswith minimumcement contentof350 kg/m3andmaximumwatercementratioof0.50including admixture(plasticiser, ‘super plasticiser)inrecommended proportionsasperIS:9103toaccelerate,retardsettingofconcrète,improve workabilitywithout impairing strengthand durabilitywith about (5.0 cu.m.)7730 kg. of 20mm machine crushed stone jelly and withabout(3.30 cu.m.) 5156 kg.of 10 -12mm machinecrushedstonejelly andwithabout(4.79 cu.m.) 7670kg.ofsand,butexcluding costofreinforcementgrillandfabricatingcharges,centeringand shutterlngandalsoincludinglaying,vibratingwithmechanicalvibrators,finishing,curing,etc.andproviding fixtureslike fan clamps inthe RCCfloor/roof slabswherevernecessarywithoutclaimingextra, etc., complete complyingwithstandardspecification andasdirectedbythedepartmentalofficers. Thecoarseandfine aggregatestobe usedshouldcomplywiththerequirementsofISStandards. (Noseparatepaymentwillbe made by the Department for the excess usage of materials). 11 ProvidingandlayinginpositionReadymixedReinforced CementConcreteofM 30grade in accordance with IS 456-2000 using 20mm size (HBGS) hard broken granite stone jelly for RCC works to attain the specified characteristic strength not less than 30N/mm2 at 28 days and manufactured in fully automatic batching plant and transported to site of work in transmit mixer including pumping RMC from transmit mixer for all leads, having continuous agitated mixer, including pumping RMC from transit mixer to site of laying admixtures in recommended proportions as per IS 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in charge including production cost of concrete by mixer plant including batching, mixing, hire charges for machineries such as batching plant, Generator, and carriage of concrete by transporting the concrete from batching plant to the site by using transit mixer including charges for operator and helpers and pumping of concrete from site to the required location including hire charges of pump, piping work and accessories etc., labour for pouring, consolidating and etc., complete complying with standard specifications and as directed by the departmental officers. 12 Supplying and fabrication and placing in position of Mild Steel / Ribbed Tor steel for all RCC works including cost of steel and G.I. binding wire etc., complete complying with standard specification and as directed by the departmental officers. 13 Supplying and erecting steel centering for sides and soffits without strutting for plain surface with all cross bracings using Mild steel sheets of size 90cm x 60cm. Thickness ofB.G. 10 stiffened with welded Mild steel angles of size 25 x 25 x 3mm for boarding laid over country wood joists of size 10cm x 6.5cm spaced at 90cm. Center to centeretc., complete complying with standard specification and as directed by the departmental officers. 14 Supplying and erecting steel centering for sides and soffits with strutting upto 3m height for plain surface with all cross bracings using Mild steel sheets of size 90cm x 60cm. Thickness ofB.G. 10 stiffened with welded Mild steel angles of size 25 x 25 x 3mm for boarding. laid over country wood joists of size 10cm x 6.5cm spaced at 90cm. Center to center and supported by Casuarina props of 10 to 13cm dia. (spaced at 75cm) center to center etc., complete complying with standard specification and as directed by the departmental officers. 15 Fabricating, Supplying and erection of Screw gearing steel shutters of size above 2.00 m and upto 3.00m width consist of skin plate made out of 10mm thick mild steel plate and horizontally stiffened with 150x75mmISMB 150 at an intervalnot more than 0.50m and vertical stiffeners made out of 100x50mm mild steel channel ISMCat an interval not more than 0.60m and provided with 10mm thick mild steel gusset plate of required size on both sides fastened with rust free bolts and nuts etc. Conveying the fabricated shutter by using lorries including loading, unloading and leading the shutter to the vent. Dismantling the eroded shutter and shuttering arrangements by using necessary gas cutting equipment. Erecting the new shutter and the shuttering arrangements in the vent in proper position by using necessary hoisting equipment. The shutter shall be painted with two coats of Anticorrosive black paint over one coat ofRed Oxide Primer. The rate including cost of materials consumables, labours power charges, conveyance charges for all equipment required conveying the dismantled materials to the section stores, cost of petty civil works, trial operation of shutter and warranty for 5 years etc.,complete complying with standard specification and as directed by the departmental officers. 16 Fabricating supplying and fixing of shutter Groove Angle made up of65 x 65 x 6 mm Mild Steel angle for required height including welding hold fast of size 25 x 25 x 6 mm Mild steel angle 2 Nos on both sides,conveying and leading the groove angle to the vents. Fixing the angle to the grooves in proper alignment including dismantling the existing damaged groove angles, conveying and stacking at section store. The Groove angle should be painted with two coatsof Anticorrosiveblack paint over one coat of red oxide primer. The rate including cost of materials, consumables, labours, charges for all fabricating and hoisting equipments, conveyance, petty civil worksand warrantyfor5 yearsetc., completecomplying with standard specification and as directed by the departmental officers. 17 Fabricating, supplying and fixing of 63mm dia Screw Rod made up of Mild Steel duly machined and fully threaded to suit the Head set Assembly and provided with required holes. Conveying and leading the screw rod to the worksite. Fixing the screw rod to the shutter gusset plate with required bolt and nut in proper alignment to the head set including dismantling the existing damaged screw rod, conveying and stacking at section store. The Screw rod should be painted with two coats of AC black paint over one coat of red oxide primer. The rate including cost of materials, labours, charges for all fabricating and hoisting equipments, conveyance charges for labours and materials and warranty for 5 years etc., complete complying with standard specification and as directed by the departmental officers. 18 Fabricating, Supplying and fixing of Top Beam made up of 150x75mm (ISMB 150) duly drilled to suit the Head Set Assembly with required bed boltmade out of 25mm mild steel round rod duly threaded with suitable anchorage arrangements to a height of 0.60m with necessary Fish plate made out of 12mm mild steel plate of size 0.30x 0.15m 2 Nos with required holes.Conveying and leading the top beam arrangements to the work site. Fixing the top beam arrangements at the top of the vent in correct position including dismantling the existing eroded top beam, conveying and stacking and the section stores. The top beam should be painted with two coats of AC black paint over one coat of Red Oxide primer. The Rate including cost of materials, labours, charges for all fabricating and hoisting equipments, cost of petty civil works conveyance charges for labours and materials and warranty for 5 years etc.., complete complying with standard specification and as directed by the departmental officers. 19 Supplying and fixing of Head Set Assemblyheavy duty with hexagonal nut (approximate 120 Kg) made up of cast iron including moulding, machining and the hexagonal nut threaded to suit the Screw Rod provided with thrust bearingsfor smooth operation. Conveying and leading the head set assembly to the work site. Fixing the head set assembly to the top beam by using required rust free bolts and nuts in proper alignment including dismantling the existing damaged Head set assembly, conveying and stacking at section store. The Head set assembly supplied with operating key and the both should be painted with two coats of AC black paint over one coat of red oxide primer. The rate including cost of materials, labours, charges for wooden pattern, moulding and charges for all machining equipments, conveyance charges for labours and materials and warranty for 5 years etc., complete complying with standard specifications, and as directed by the departmental officers. 20 Dewatering using 7.5 HP Diesel Engine pumpset including Hire charges, cost of Diesel Engine oil, Pump operator, labour charges,conveyance of pumpset and fuel to site and back,loading, unloading and any other incidentialcharges etc.,complete complying with standard specification and as directed by the departmental officers. 21 Earth work excavation deploying earth moving machinery for desilting channel having a width of more than10m and forming bund on either side and depositing the earth on banks including jungle clearance etc complete complying with standard specifications and as directed by the departmental officers.
Contract Date: Jan 08, 2026 Contract Value : 4.91 Crore
Government Departments No of Bidders 3
46.
Educational and Research Institute #9392647 Technical Bid
Supply Of Printed Books As Per Tender Document , Supply Of Printed Books , Heat Transfer/Binay K. Dutta/Phi Learning Private Limited/978-81-203-1625-6 , Stoichiometry And Process Calculations/K.V.Narayanan And B.Lakshmikutty/Phi Learning Private Limited/978-8120352896 , Elements Of Chemical Reaction Engineering/H. Scott Fogler/Phi Learning Private Limited/978-7502741006 , Chemical Reaction Engineering/Octave Levenspiel/Wiley/978-8126510009 , Mass Transfer Operations/Robert Treybal/Mcgraw Hill Education/N/A , Transport Processes And Separation Process Principles/Chistie John Geankoplis/Pearson Education India/N/A , Principles Of Mass Transfer And Separation Processes/Binay K. Dutta/Phi Learning Private Limited/N/A , Chemical Process Safety: Fundamentals With Applications /Daniel Crowl , Joseph Louvar/Pearson Education India/N/A , Transport Phenomena/R. Byron Bird, Warren E. Stewart, Edwin N. Lightfoot/Wiley/N/A , Chemical Process Control: An Introduction To Theory And Practice/George Stephanopoulos/Pearson/N/A , Process Systems Analysis And Control/Steven E Leblanc Donald R. Coughanowr/Mcgraw Hill Education/N/A , Chemical Engineering Design: Principles, Practice And Economics Of Plant And Process Design/Gavin Towler, Ray Sinnott/Butterworth-Heinemann Ltd/N/A , Plant Design And Economics For Chemical Engineers/Max Peters, Klaus Timmerhaus, Ronald West, Max Peters/Mcgraw Hill/N/A , Unit Operations Of Chemical Engineering/Warren Mccabe/Mcgraw Hill Education/N/A , Process Plant Simulation/B.V Babu/Oxford University Press/N/A , A Textbook Of Machine Design/R.S.Khurmi/S Chand/N/A , Mechanical Operations Fundamental Principles And Applications/Dr. Kiran D. Patil/Nirali Prakashan/N/A , Unit Operation -1/K. A. Gavhane/Nirali Prakashan/N/A , A Textbook Of Heat And Mass Transfer/Rk Rajput/S Chand/N/A , Numerical Methods For Engineers/Steven Chapra Raymond Canale/Mcgraw Hill Education/N/A , A Text Book Of Railway Engineering/Saxena S.C /Dhanpat Rai Publication/N/A , Adsorption Analysis: Equilibria And Kinetics (With Cd Containing Computer Matlab Programs): 2 (Series On Chemical Engineering)/ Duong D Do/Imperial College Press/978-1860941375 , Advanced Concrete Technology/Zongjin Li/John Wiley & Sons Ltd/978-0470437438 , Advanced Mechanics Of Solids/Srinath, L.S./Tata Mcgraw-Hill/978-0070139886 , Advanced Reinforced Concrete Design/Krishnaraju N/Cbs Publishers/978-8123929606 , Alkali-Aggregate Reaction And Structural Damage To Concrete /Geoffrey E Blight/Crc Press/978-1138073036 , An Introduction To The Finite Element Method/Reddy, J.N./Mcgraw Hill/978-9390385270 , Basic Structural Analysis/Reddy, C. S./Tata Mcgraw Hill/978-0070702769 , Classical And Computational Solid Mechanics/Fung,Tong And Chen/World Scientific Publishing Co Pte Ltd/978-0000988508 , Concrete Structures/Bhattacharjee J/Cbs Publishers/978-9385915901 , Concrete Structures Subjected To Impact And Blast Loadings And Their Combinations/Zhang Chunwei/Taylor & Francis Ltd/978-1032200514 , Concrete Technology/A M Neville/Pearson Education/978-8131705360 , Construction Materials Their Nature And Behaviour/Marios Soutsos, Peter Domone/Crc Press/978-1498741101864 , Design Of Reinforced Concrete Structures/Subramanian N/Oup India/978-0198086949 , Dynamics Of Structures/Clough,R.W. And Penzien, J/Mcgraw Hil/978-8123926636 , Elasticity And Plasticity: The Mathematical Theory Of Elasticity And The Mathematical Theory Of Plasticity/J.N. Goodier/Dover Publications Inc./ 978-0486806044 , Elements Of Strength Of Materials/Timosenko, S. P., And Young, D.H./Affiliated Eastwestpress Pvt. Ltd/978-8176710190 , Engineering Mechanics Of Solids/Popov, E.P./Pearson Education India/9332550216 , Environmental Engineering/Howard S Peavy, Donald R Rowe/Mcgraw Hill Education/978-9351340263 , Environmental Engineering (Vol. I) Water Supply Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174091208 , Environmental Engineering (Vol. Ii) Sewage Waste Disposal And Air Pollution Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174092304 , Finite Element Analysis: Theory And Programming/C. S. Krishnamurthy/Mcgraw Hill/978-0074622100 , Foundations Of The Theory Of Elasticity, Plasticity, And Viscoelasticity /Eduard Starovoitov And Faig Bakhman Ogli Naghiyev/Apple Academic Press Inc./978-1774631997 , Handbook Of Solid Waste Management/George Tchobanoglous, Frank Kreith /Mcgraw Hill Education/978-0071356237 , Highway Engineering/Khanna & Justo/Nemchand Publisher/8185240930 , Industrial Water Pollution Control/W Wesley Eckenfelder/Mcgraw Hill Education/978-9339220433 , Integrated Design And Environmental Issues In Concrete Technology/K Sakai/Crc Press/978-0367864620 , Intermediate Structural Analysis/Wang, C.K./Mcgraw Hill Education/978-0070702493 , Introduction To Solid Mechanics/Shames, H/Phi/978-9332549906 , Introduction To Traffic Engineering/R Srinivasa Kumar/The Orient Blackswan; South Asian Edition/9386235471 , Matrix And Finite Element Analysis Of Structures/Madhujit Mukhopadhay And Abdul Hamid Sheikh/Anebooks Pvt. Ltd./978-81-8052-075-4 , Microwave-Assisted Concrete Technology/Ong K.C. Gary/Crc Press/978-1138748897 , Prestressed Concrete /Krishnaraju N/Mcgraw Hill Education India/978-9387886209 , Principles Of Adsorption And Adsorption Processes/ Douglas M. Ruthven/Wiley-Interscience/978-0471866060 , Properties Of Concrete/A M Neville/Pearson Education/978-0273755807 , Random Vibrations Of Elastic Systems/Bolotin, V. V./Springer/978-9048182800 , Recent Trends In Solid Waste Management (Advances In Pollution Research)/Balasubramani Ravindran,Sanjay Kumar Gupta/Elsevier - Health Sciences Division/978-0443152061 , Reinforced Concrete: Mechanics And Design, Global Edition /Wight James/Pearson Education Limited/978-1292106007 , Soil Mechanics And Foundation Engineering - Geotechnical Engineering/K.R.Arora/Standard Publisher Dist/8180141128 , Solid Mechanics /Kazimi, S. M.A/Tata Mcgraw-Hill/978-0074517154: ? , Sprayed Concrete Technology/Simon Austin/Crc Press/978-0367865412 , Standard Methods For The Examination Of Water And Wastewater/William C. Lipps, Ellen Burton Braun-Howland, Terry E. Baxter/American Public Health Association/978-0875532998 , Statically Indeterminate Structures/Wang, C.K./Mcgraw Hill Book Company/978-9352604722 , Strength Of Materials/Srinath, L.S, Desayi./Macmillan Publishers India/978-0333923924 , Strength Of Materials, Part 1/Timoshenko, S/Mcgraw Hill/978-8123910307 , Strength Of Materials, Part 2/Timoshenko, S/Mcgraw Hill/978-8123910772 , Structural Dynamics/Mario Paz/Cbs Publications/978-8181287724 , Structural Dynamics- Theory And Application To Earthquake Engg/Anil K Chopra/Pearson Education/978-9353945251 , Structural Dynamics: Vibrations And Systems/Mukhopadhyaya, M./Ane Books /978-8180520907 , Sulfate Attack On Concrete/Jan Sklany/Taylor & Francis Ltd/978-0367447144 , Textbook Of Highway And Traffic Engineering/Saxena S.C /Cbs /978-8123924175 , The Finite Element Method Its Basis & Fundamentals/Zienkiewicz, Taylor And Zhu/Elsevier/978—81-312-118-2 , Theory Of Elasticstability/Timoshenko, S.P. And Gere, J. M./Tata Mcgraw Hill./978-0-07-0702417 , Theory Of Elasticity/Timoshenko And Goodier/Mcgraw Hill/978-0070701229 , Theory Of Elasticity And Plasticity: A Textbook Of Solid Body Mechanics/Antonina Molotnikova And Valentin Molotnikov /Springer Nature/978-3030666248 , Theory Of Plates And Shells/Timoshenko And Kriger/Tata Mcgraw Hill/978-0-07-070125-0 , Traffic & Highway Engineering/Nicholas J. Garber/Cengage India Private Limited/978-8131529430 , Traffic Engineering/R P. Roess (Author), Elena S. Prassas (Author), William R. Mcshane (Author)/Pearson Education/9353434858 , Wastewater To Water: Principles, Technologies And Engineering Design/Makarand M. Ghangrekar/Springer Verlag, Singapore/978-9811940507 , Soil Dynamics And Machine Foundations/Swami Saran/Galgotia Publication S Pvt. Ltd./978-8175157279 , Soil Mechanics And Foundation Engineering/K. R. Arora/Standard Publishers/978-8180141126 , Basic And Applied Soil Mechanics/Gopal Ranjan, Asr Rao/New Age International/9788122440393, , Design Of Steel Structures/N. Subramanian/Oxford University Press/978-0199460915 , Fundamental Concepts Of Earthquake Engineering /Roberto Villaverde/Crc Press/1420064959 , Civil Engineering Drawing /M Chakraborti// , Data Mining Concepts And Techniques /Jiawei Han, Jian Pei,Hanghang Tong/Elsevier/9788131267660 , Data Science In Practice/Tom Alby/Chapman & Hall/9781032505268 , Introduction To Data Science: Practical Approach With R And Python/B. Uma Maheswari, R. Sujatha/Wiley/9789354640506 , Transformers For Natural Language Processing And Computer Vision - Third Edition/Denis Rothman/Packt Publishing/9781805128724 , Generative Deep Learning/ David Foster/Oreilly Media/9781098134181 , Introduction To Machine Learning /Ethem Alpayd?N/Mit Press/9780262043793 , Data Mining With R/Luis Torgo/Taylor And Francis/9780367372453 , Bioinformatics And Functional Genomics/Jonathan Pevsner/Wiley Blackwell Pub/978-1118581780 , Bioinformatics Basics: Applications In Biological Science And Medicine/ Lukas K. Buehler/Crc Press/978-0367392598 , What Is The Name Of This Book?/Raymond M. Smullyan/Dover Publications Inc./978-0486481982 , The Lady Or The Tiger?/Raymond M. Smullyan/Dover Publications Inc./978-0486470276 , The Riddle Of Scheherazade: And Other Amazing Puzzles, Ancient And Modern./Raymond M. Smullyan/Knopf/978-0679446347 , Convex Optimization/Stephen Boyd, Lieven Vandenberghe/Cambridge University Press/978-0521833783 , Genetic Algorithms In Search, Optimization And Machine Learning/David E. Goldberg/Pearson/978-8131709931 , Steganography In Digital Media: Principles, Algorithms, And Applications/Jessica Fridrich/Cambridge/978-0521190190 , Deep Learning From Scratch: Building With Python From First Principles/Seth Weidman/Shroff/Oreilly/978-9352139026 , Wireless Communication Systems /Rajeshwar Dass./Wiley/978-9389583687 , Semiconductor Materials, Devices, And Fabrication, As Per Aicte/Parasuraman Swaminathan/Wiley/978-8126508624 , Introduction To 4G Mobile Communications/Juha Korhonen/Artech House Publishers/978-1608076994 , An Introduction To Lte/Cox Christopher/Wiley/978-1118818039 , Fourth Generation Mobile Communication/Curwen Peter/Springer International Publishing Ag/978-3319022093 , Advanced Wireless Communications: 4G Technologies/Savo G. Glisic/Wiley–Blackwell/978-0470867761 , 4G Wireless Communication Networks: Design Planning And Applications/Johnson I. Agbinya, Mari Carmen Aguayo-Torres, Ryszard Klempous/River Publishers/978-8792982711 , Fundamentals Of Lte/Rews, Rias Muhamed, Arunabha Ghosh, Jun Zhang, Jeffrey G./Pearson/978-9353062392 , 5G Mobile Communications/Wei Xiang, Kan Zheng, Xuemin (Sherman) Shen/Springer International Publishing Ag/978-3319342061 , 5G Mobile Core Network: Design, Deployment, Automation, And Testing Strategies/Rajaneesh Sudhakar Shetty/Springer India/978-1484283288 , 5G Mobile And Wireless Communications Technology/Afif Osseiran, Jose F. Monserrat, Patrick Marsch, Mischa Dohler, Takehiro Nakamura/Cambridge University Press/978-1107130098 , Towards 5G: Applications, Requirements And Candidate Technologies/Rath Vannithamby, Shilpa Talwar/Wiley/978-1118979839 , Fundamentals Of 5G Mobile Networks/Jonathan Rodriguez/Wiley/978-1118867525 , A Course In Electrical And Electronic Measurements And Instrumentation/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited;/978-8177001006 , A Course In Electrical Machine Design/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited /978-8177001013 , A Course In Electrical Technology (Basic Electrical Engineering Volume I)/J.B.Gupta/S.K. Kataria & Sons/81-85749-29-9 , A First Course On Electrical Drives/S.K.Pillai/New Age International Publishers/978-8122433616 , A Text Book Of Electrical Technology (Vol.1)/B.L.Theraja, A.K.Theraja/S.Chand Technical/9788121924405 , A Textbook Of Electrical Technology Volume Ii : Ac And Dc Machines/B.L.Theraja, A.K.Theraja/S Chand/978-8121924375 , Advanced Electrical Technology/H. Cotton/Reem Publications Pvt. Ltd. /978-8190630719 , An Integrated Course In Electrical Engineering/J.B.Gupta/S.K. Kataria & Sons/9-789350143681 , An Introduction To Analog And Digital Communication Systems/ Simon Haykin, Michael Moher /Wiley/978-8126536535 , An Introduction To The Principles Of Digital Communications/N.B.Chakraborti, A.K.Datta/New Age International Publishers/978-8122420838 , Analog Communication Systems/Sanjoy Sharma/S.K. Kataria & Sons/978-9350143797 , Artificial Intelligence And Intelligent Systems/N.P. Padhy/Oxford University Press/978-0195671544 , Artificial Neural Networks/B. Yegnanarayan/Prentice-Hall Of India Pvt. Ltd., New Delhi/ 978-8120312531 , Automatic Control System/ B. C. Kuo/ Prentice Hall Of India/9788120309685 , Automatic Control Systems (With Matlab Programs)/S. Hasan Saeed/Arihant Publisher/978-8190691925 , Basic Electrical Engg./D.P. Kothari & I.J. Nagrath/Mcgraw-Hill/9780070146112 , Basic Electrical Engg./V.K.Mehta, Rohit Mehta/S.Chand /978-8121908719 , Basic Electrical Engineering/A.E Fitzgerald, David E. Higginbotham, Arvin Grabel/ Mcgraw Hill Education/978-0070682566 , Circuit Theory (Analysis & Synthesis)/A.Chakraborti/Dhanpat Rai & Co./9788177000009 , Circuit Theory & Network/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9780071329040 , Communication Systems/Sekar, V. Chandra//978-0198078050 , Control System Engineering (Student Edition)/Norman Nise/John Wiley & Sons/978-8126537280 , Control Systems - I /S. Hasan Saeed/S.K. Kataria & Sons/978-9350141335 , Control Systems Engineering/I.J. Nagrath &M.Gopal/New Age International Pvt Ltd Publishers/9789386070111 , Design And Applications Of Analog Integrated Circuits/Soclof/Phi Learning Private Limited/978-81-203-2552-4 , Digital Communications/Sanjoy Sharma/S.K. Kataria & Sons/978-9350142684 , Digital Control Engineering/M. Gopal/New Age International Publishers/978-8122436617 , Digital Control Systems/B.C.Kuo/Oxford University Press/978-0198083542 , Digital Design/M. Morris Mano/Prentice Hall/978-0132774208 , Digital Electronics /G.K.Kharate/Oxford University Press/9-780198061830 , Digital Integrated Electronics/H. Taub And D. L. Schilling/Mcgraw Hill Education/978-0070265080 , Digital Signal Processing/Monson H Hayes/Tata Mcgraw - Hill Education/978-0070153868 , Digital Signal Processing/P.Ramesh Babu/Scitech Publications/978-8183710817 , Digital Signal Processing/B. Kumar/New Age International Publishers/978-8122436099 , Digital Signal Processing: A Computer Based Approach/S. K. Mitra/Mcgraw Hill Education/978-1259098581 , Direct Energy Conversion/Kettani, M. Ali/Addison-Wesley/ 97-80201036633 , Direct Energy Conversion/Stanley W. Angrist/Allyn And Bacon/978-0205077588 , Distributed Generation: Induction And Permanent Magnet Generators/Loi Lei Lai, Tze Fun Chan/Wiley/978-0470062081 , Distributed Generation: The Power Paradigm For The New Millennium/Anne-Marie Borbely, Jan F. Kreide/Crc Press/978-1420042399 , Electric And Hybrid Vehicles/Tom Denton/Routledge/9781138842373 , Electric Circuits /David. A. Bell/Oxford University Press/9780195694284 , Electric Energy Systems Theory-An Introduction/Olle I. Elgerd/Tata Mcgraw Hill/9780070992863 , Electric Machines/ I. J. Nagrath And D. P. Kothari/Tata Mcgraw Hill/978-0070699670 , Electrical Circuit Analysis (Including Passive Network Synthesis)/C.L.Wadhwa/New Age International Publishers/978-8122418521 , Electrical Engineering Fundamentals/Vincent Del Toro/Phi Learning Private Limited/978-8120305991 , Electrical Engineering Materials/T.K.Basak/New Age International Publishers/978-8122427738 , Electrical Machinery/Dr. P.S.Bimbhra/Khanna Publishers/978-8174091734 , Electrical Machinery /S. K. Sen/Khanna Publishers /978-8174091529 , Electrical Machines/R.K.Rajput/Laxmi Publications(P) Ltd./978-8131804469 , Electrical Machines /S.K.Bhattacharya/Tata Mcgraw-Hill Education/978-9332902855 , Electrical Measurements And Measuring Instruments/ E.W Golding, F.C Widdis/Reem Publications Pvt. Ltd/978-8190630726 , Electrical Power System Quality/R.C.Dugan/Tata Mcgraw-Hill Education, 2003/978-1259005572 , Electrical Power Systems/Ashfaq Husain/Cbs Publishers & Distributors/978-8123914480 , Electromagnetic Fields & Waves96/Sarwate V.V./New Age/81-224-0468-5 , Electromagnetic With Application/J. D. Krauss/Tata Mcgraw Hill/9780070702400 , Electromagnetics/B.B.Laud/New Age International Publishers/978-8122430554 , Electromagnetism – Theory And Applications/Ashutosh Pramanik/Prentice-Hall Of India/978-8120319578 , Electronic Devices And Circuit Theory/R. Boylestad And L. Nashelsky/Prentice Hall Publishing Co/978-0132504577 , Electronic Devices And Circuits/J. Millman And C. C. Halkias/Mcgraw Hill Education/978-0070423800 , Electronic Instrumentation/H.S.Kalsi/Mcgraw Hill Education/978-0070702066 , Elements Of Advanced Quantum Theory/J.M. Ziman/Camridge University Press/521-07458-4 , Elements Of Electrical Power Station Design/M.V.Deshpande/Prentice Hall India Learning Private Limited /978-8120336476 , Elements Of Photonics Vol-1 /Keigo Lizuka/Wiley-Interscince/0-471-83938-8 , Elements Of Power System Analysis/W.D. Stevenson/Mcgraw Hill Higher Education/978-0070665842 , Energy Economics: Concepts, Issues, Markets And Governance/Subhes C. Bhattacharyya/ Springer/978-1447174707 , Energy Science Principles, Technologies And Impact/J. Andrews, N. Jelley/Oxford University Press/978-0198755814 , Energy Technology - Nonconventional, Renewable & Conventional/S.Rao, Dr. B.B.Parulekar/Khanna Publishers/97-88174090401 , Energy Technology (Non Conventional, Renewable And Conventional)/Prof. Sunil S. Rao And Dr. B.B. Parulekar/Khanna Publishers/978-81-7409-040-9 , Engineering Circuit Analysis/W. H. Hayt , J. Kemmerly /Mcgraw Hill Education/978-1259098635 , Engineering Electromagnetic/W. H. Hayt & J. A. Buck/Mcgraw-Hill/978-9353169725 , Engineering Electromagnetics/Hayat/Tmh/0-07-061223-4 , Engineering Optimization Theory And Practice/Singiresu S. Rao/New Age International Publishers/978-8122427233 , Engineering Thermodynamics/P.K.Nag/ Mcgraw Hill Education/978-9352606429 , Explanations / Solutions To An Integrated Course In Electrical Engineering (With About 15,000 Objective Type Questions & Answers) /J.B.Gupta/S.K. Kataria & Sons/978-9350146668 , Facts Controllers In Power Transmission And Distribution/K.R. Padiyar/New Age International Publishers/978-8122421422 , Fiber Optics Essentials/K. Thyagarajan & Ajoy Ghatak/Wiley-Interscince/978-0-470-09742-7 , Fiber Optics Through Experiments Paperback – 2011/Ajoy Ghatak, M. R. Shenoy /Viva Books (2011)/978-8130918112 , Fiber-Optic Communication Systems/Govind P. Agrawal/Wiley/978-8126513864 , Fibre Optics And Optoelectronics/R.P.Khare/Oxford University Press/9-780195669305 , Flexible Ac Transmission Systems/Yong Hua Song, Allan T. Johns/ Laxmi Publications /978-8190858809 , Fundamentals Of Digital Circuits/A. Anand Kumar/Prentice-Hall Of India Pvt. Limited/978-8120352681 , Fundamentals Of Electric Circuits/Charles K. Alexander, Matthew N. O. Sadiku/Mcgraw Hill Education (India) Private Limited/978-9355320162 , Fundamentals Of Microprocessors And Microcontrollers/B. Ram/Dhanpat Rai Publications (P) Ltd/978-9383182107 , Fundamentals Of Optical Wave Guides/Katsunari Okamoto/Elsevier/978-0-12-525-096-2 , Fundamentals Of Photonics /Bahaa E. A. Saleh, Malvin Carl Teich/ John Wiley & Sons, Inc./0-471-2-1374-8 , Fundamentals Of Power Electronics/Robert W. Erickson, Dragan Maksimovic/Springer Us/978-1-4757-0559-1 , Generation Distribution And Utilization Of Electrical Energy/C.L. Wadhwa/New Age International Publishers/978-8122428216 , Getting Started With Matlab/Rudra Pratap/Oxford University Press/978-0198069195 , Goldings Electrical Measurements And Measuring Instruments/Golding & Widdis/Medtech Publishers/978-9387210349 , Handbook Of Energy Conservation, Vol. 1/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912066 , Handbook Of Energy Conservation, Vol. 2/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912073 , High Voltage Engineering/C.L.Wadhwa/New Age International Publishers/978-8122430905 , High Voltage Engineering/M.S Naidu & V Kamaraju/Mcgraw Hill Education/978-1259062896 , High Voltage Engineering: Problems & Solutions/R.D. Begamudre/New Age International Publishers/978-8122426182 , Hvdc Power Transmission Systems/K.R. Padiyar/New Age International Publishers/978-8122437850 , Industrial Energy Conservation Techniques : Concepts, Applications And Case Studies /K. Nagabhushan Raju/Atlantic Publishers And Distributors (P) Ltd/978-8126907748 , Industrial Instrumentation/Donald P. Eckman/Cbs Publisher/978-8123908106 , Industrial Instrumentation/K.Krishnaswamy, S. Vijayachitra/New Age International Publishers/978-8122427509 , Industrial Instrumentation, Control And Automation/Mukhopadhay, Sen & Deb/Jaico Publishing House/978-8184954098 , Instrumentation And Control/Patranabis/Phi Learning Private Limited/978-81-203-4246-0 , Introduction To Digital Signal Processing/J.R. Johnson/ Prentice Hall India Learning Private Limited /978-8120307605 , Introduction To Fiber Optics (English) 1St Edition/Ajoy Ghatak , K. Thyagarajan/Cambridge University Press-New Delhi/97-88175960626 , Introduction To Quantum Mechanics/David J. Griffiths/Prentice Hall/0-13-124405-1 , Introduction To Quantum Mechanics/A.C. Philips/John Wiley & Sons, Inc./0-470-85323-9 , Introduction To Solid State Physics/ Charles Kittel /Wiley & Sons/978-8126535187 , Lasers And Non-Linear Optics/B.B.Laud/New Age International Publishers/978-8122430561 , Linear Integrated Circuits/D. Roy Choudhury, Shail B. Jain/New Age International Publishers/978-8122430981 , Matrix Analysis Of Electrical Machines/Ashoke Kumar Mukhopadyhay/New Age International Publishers/978-8122432398 , Microcomputer Systems: The 8086/8088 Family/I. Liu, G. A. Gibson/ Prentice Hall India Learning Private Limited/978-8120304093 , Microelectronic Circuits: Theory And Applications/A.S. Sedra And K.C. Smith/Oxford University Press/978-0199476299 , Microelectronics/J. Millman And A. Grabel/Mcgraw Hill Education/978-0074637364 , Microprocessor Architecture, Programming And Applications With The 8085A/8080A/Ramesh S. Gaonkar/Wiley Eastern Ltd./978-0852262979 , Microprocessors Interfacing/Douglas Hall/Mcgraw Hill Education/978-1259006159 , Modern Digital And Analog Communication Systems/B.P.Lathi/Oxford University Press/978-0198073802 , Modern Electronic Instrumentation And Measurement Techniques /A D Helfrick; W D Cooper/ Prentice Hall India Learning Private Limited/?978-9332556065 , Modern Power System Analysis/I.J. Nagrath And D.P. Kothari/Mcgraw Hill Education/978-0071077750 , Modern Quantum Mechanics /J.J.Sakurai/Addison -Wesley Publishing Company/0-201-53929-2 , Network Analysis And Synthesis/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9781259081422 , Network Analysis And Synthesis/Franklin F. Kuo /Wiley/978-8126510016 , Network Analysis And Synthesis (Including Linear System Analysis)/C.L.Wadhwa/New Age International Publishers/978-8122420364 , Networks And Systems/D. Roy Choudhury/New Age International Publishers/978-8122427677 , Neural Networks In Computer Intelligence /F. Limin/Mcgraw Hill Education/978-0070532823 , Neural Networks, Fuzzy Logic And Genetic Algorithms: Synthesis And Applications/S. Rajasekaran And G.A. Vijaylakshmi Pai,/Prentice-Hall Of India Pvt. Ltd., New Delhi/978-8120321861 , Non Conventional Energy Resources/D.S. Chauhan, S.K.Srivastava/New Age Int.(P) Ltd/978-81-224-3399-9 , Non-Conventional Energy Resources/B.H. Khan/Tata Mcgraw Hill/978-0070142763 , Non-Conventional Energy Resources/D.S. Chauhan/New Age International Publishers/978-8122433999 , Non-Conventional Energy Sources/G.D. Rai/Khanna Publishers/9-788174090737 , Nonlinear Fiber Optics/Govind P. Agrawal/Optics And Photonics/N/A , Nonlinear Optics /Robert W. Boyd/Academic Press/0-12-121682-9 , Objective Electrical Technology/V.K.Mehta, Rohit Mehta/S. Chand Publishing/978-9355014467 , Op-Amps And Linear Integrated Circuits/Gayakwad/Phi Learning Private Limited/978-81-203-2058-1 , Operational Amplifiers And Linear Ics/David. A. Bell/Oxford University Press/978-0195696134 , Optical Electronics /A.K.Ghatak & K.Thyagarajan/Camridge University Press/0-521-30643-4 , Optical Waves In Crystals/Amnon Yariv & Pochi Yeh/Wiley-Interscince/0-471-09142-1 , Optimization Of Power System Operation/Jizhong Zhu/Wiley/978-1-118-85415-0 , Parker Smiths 500 Solutions Of Problems In Electrical Engineering (Part 1)/V.C Nateshan/Cbs /N/A , Performance And Design Of Ac Machines/M. G. Say/Cbs Publishers/978-8123910277 , Photonics/Amnon Yariv & Pochi Yeh/Oxford University Press/978-0-19-517946-0 , Power Electronics/Dr. P. S. Bhimbra/Khanna Publisher/978-81-7409-279-3 , Power Electronics: Converters, Applications, And Design/Ned Mohan, Tore M. Undeland, William P. Robbins/Wiley India/978-8126510900 , Power Electronics: Devices, Circuits And Applications/Muhammad H Rashid/Pearson Education/978-9332584587 , Power Electronics: Essentials & Applications/L. Umanand/Wiley/978-8126519453 , Power Generation, Operation, And Control/Allen J. Wood, Bruce F. Wollenberg/John Wiley & Sons/978-8126508389 , Power Plant Engineering/Arora & Domkundwar/Dhanpat Rai & Co. (P) Limited/978-8177001952 , Power Plant Engineering/A.K.Raja, Amit Prakash Srivastava, Manish Dwivedi/New Age International Publishers/978-8122418316 , Power Plant Technology/M.M.El-Wakil/Mcgraw Hill Education/978-0070702448 , Power System Analysis/J.J.Grainger, W.D.Stevenson/Tata Mcgraw-Hill/978-0070612938 , Power System Analysis: Operation And Control/ Abhijit Chakrabarti, Sunita Halder/Phi Learning Pvt. Ltd./ 978-8120340152 , Power System Optimization: Stability And Control/K. R. Padiyar/Anshan Ltd./978-1904798019 , Power System Optimization/D .P. Kothari And J.S Dhillon/Prentice Hall India Learning Private Limited/?978-8120340855 , Power System Prorection And Switchgear/B. Ravindranath And M. Chander/New Age International Publishers/978-8122430325 , Power System Protection/S. P. Patra, S. K. Basu, S. Choudhuri/Oxford & Ibh Publishing Co./N/A , Power System Protection And Communications/Akhter Kalam/New Age International Publishers/978-8122427417 , Power System Protection And Swichgear/B. Ravindranath, M. Chander/New Age International Publishers/978-8122430325 , Power System Restructuring And Deregulation/Loi Lei Lai/John Wiley & Sons Ltd /978-8126547234 , Power System Stability Vol-I/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power System Stability And Control/Prabha Kundur/Tata Mcgraw-Hill Education Private Limited/978-0070635159 , Power System Stability Vol-Ii/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power Systems Analysis/ Arthur Bergen, Vijay Vittal / Pearson/978-0136919902 , Principles Of Electromagnetics/Matthew N.O. Sadiku/Oxford University Press/9780198062295 , Principles Of Electronic Instrumentation/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Principles Of Industrial Instrumentation/D. Patranabis/Mcgraw Hill Education/978-0070699717 , Principles Of Power Systems/V.K.Mehta, Rohit Mehta/S.Chand & Co./978-8121924962 , Principles Of Process Control/ D. Patranabis/Tata Mcgraw Hill/978-0071333252 , Principles Of Signal Processing And Linear Systems/B.P.Lathi/Oxford University Press/978-0198062288 , Problems And Solutions In Power Systems/Abhijit Chakrabarti /Abhijit Chakrabarti /978-9334032581 , Problems In Electrical Engineering(Power Engineering And Electronics With Answers Partly Solved In S.I. Units)/N. N. Parker Smith/Cbs Publisher/978-8123908588 , Process Control (Concepts, Dynamics & Applications)/S.K.Singh/Phi Learning Private Ltd./978-8120336780 , Process Control (Principles & Applications)/Surekha Bhanot/Oxford University Press/978-0195693348 , Process Dynamics And Control/D.E. Seborg, T.F. Edgar And D.A. Mellichamp/Wiley/978-8126541263 , Process Systems Analysis And Control/D.R. Coughanowr And L.B. Koppel/Mcgraw-Hill/978-0070851122 , Pulse Width Modulation For Power Converters: Principles And Practice/D. Grahame Holmes, Thomas A. Lipo/Wiley Ieee Press/978-0-471-20814-3 , Quantum Optics/Harry Paul/Camridge University Press/978-0-511-19475-7 , Reliability And Life Estimation Of Power Equipment/T.S.Ramu And Chakradhar Reddy/New Age International Publishers/978-8122426113 , Renewable Energy For Sustainable Future/Godfrey Boyle/Oxford University Press/978-0199681273 , Research Insights: A Handbook On Grant Writing And Program Management/ Rajiv K. Tayal/Atlantic Publishers And Distributors Pvt Ltd./978-8126935451 , Semiconductor-Laser Fundamentals/Weng W. Chow & Stephen W. Koch/Springer/3-540-64166-1 , Sensors And Transducers/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Signals And Systems/H. P. Hsu/Mcgraw Hill Education (India) Private Limited/978-0070669185 , Signals And Systems/A.V. Oppenheim, Schafer, R. W, A.S. Willsky And I.T. Young/ Pearson Education India/9332550239 , Smart Grid Technology And Application/Janaka Ekanayake, Kithsiri Liyanage, Jianzhong Wu, Akihiko Yokoyama And Nick Jenkins/Wiley Publications/978-0-470-97409-4 , Smart Grid: Concepts To Design/K. S. Manoj/Notion Press/9781646780006 , Smart Grid: Fundamental Of Design And Analysis/James Momoh/Wiley Publication/978-8126558124 , Solar Cell Device Physics/Stephen Fonash/Academic Press/978-0080912271 , Solar Cells: Operating Principles, Technology, And Systemapplications/Martin A. Green/Prentice-Hall/978-0138222703 , Solar Electricity Generation/S. Bhattacharjee/ Narosa Publishing House/97-88184874044 , Solar Energy/S.P. Sukhatme, J K Nayak/Tata Mcgraw Hill/978-9352607112 , Solar Photovoltaics: Fundamentals, Technologies And Applications/Chetan Singh Solanki/Phi Learning/978-8120351110 , Solid State Physics/A.J. Dekker/ Macmillan/978-0333106235 , Solid State Physics/ S.O. Pillai /New Age International Private Limited/978-9389802313 , Sustainable Energy Management/Mirjana Radovanovi? (Golusin),Stevan Popov,Sinisa Dodic /Elsevier/978-0124159785 , Taubs Principles Of Communication Systems /H. Taub And D.L. Shilling/Mcgraw Hill Education/978-0070648111 , The 8051 Microcontroller And Embedded Systems/Muhammed Ali Mazidi And Janice Gillispie Mazidi/Pearson Education India/978-0138610227 , The Theory Of Optics/Paul Drude/Longmans, Green & Co./N/A , Theory & Performance Of Electrical Machines/J.B.Gupta/S.K. Kataria & Sons/978-9350142776 , Thermal Engineering/R.K.Rajput/ Laxmi Publications/978-8131808047 , Understanding Facts: Concepts And Technology Of Flexible Ac Transmission Systems/Narain G. Hingorani, Laszlo Gyugyi/Wiley India Pvt Ltd./978-8126530403 , Signals And Systems /Ramesh Babu/Scitech Publications/978-81-8371-288-0 , Fundamentals Of Industrial Instrumentation /Barua/Wiley India/9788126528820 , Bioinstrumentation /Fulekar/Wiley India/9789389520286 , Wileys Gate Instrumentation Engineering Chapter-Wise Solved Papers (2000-2020)/Gupta/Wiley India/9788126558698 , Electronic Measurement & Instrumentation /Imam/Wiley India/9789389583021 , Electrical Measurements And Measuring Instruments/Kamakshaiah/Wiley India/9789389447521 , A Treatise On Instrumentation Engineering /Padmanabhan/Wiley India/9789389633832 , Instrumentation And Process Control /Prasad/Wiley India/9789389307191 , Biomedical Electronics And Instrumentation Made Easy /Sawhney/Wiley India/9789389795943 , Medical Instrumentation 5Ed: Application And Design, An Indian Adaptation /Webster/Wiley India/9789354249150 , Lasers And Optical Instrumentation /Nagabhushana/Wiley India/9789389698756 , Automatic Control Engineering /Gupta/Wiley India/9789389583748 , Power System Analysis: Operation And Control, 2Ed/Jena/Wiley India/9789389520415 , Process Control Engineering /Krishna/Wiley India/9789389633429 , Quality Control/Kulkarni/Wiley India/9788126519071 , Control Engineering/Kuttan/Wiley India/9789389520064 , Digital Control, W/Cd /Moudgalya/Wiley India/9788126522064 , Nises Control Systems Engineering, Wiley India Ed/Nise/Wiley India/9788126571833 , Control Systems /Padmanabhan/Wiley India/9789389633375 , Control Engineering/Ramachandran/Wiley India/9788126522880 , Power System: Operation & Control/Rao/Wiley India/9788126534418 , Matlab With Control System, Signal Processing And Image Processing Toolboxes, W/Cd /Sivanandam/Wiley India/9788126554751 , Statistical Quality Control: A Modern Introduction, 6Ed /Montgomery/Wiley India/9788126525065 , Robotics /Appu/Wiley India/9789389583281 , Fuzzy Sets And Fuzzy Logic With Engineering Applications, 4Ed, An Indian Adaptation /Rose/Wiley India/9788126502608 , Natural Language Processing/Kumar/Wiley India/9789389307597 , Optimization Techniques /Malik/Wiley India/9789389698725 , Artificial Intelligence For Dummies/Mueller/Wiley India/9788126576104 , Big Data Analytics Using Artificial Intelligence Technologies /Dixit/Wiley India/9789391029685 , Artificial Intelligence: Concepts And Applications /Goel/Wiley India/9788126519934 , Artificial Intelligence: Making A System Intelligent /Jain/Wiley India/9788126579945 , Artificial Intelligence/Kumar/Wiley India/9789389795134 , Process Dynamics And Control, 4Edan Indian Adaptation /Seborg/Wiley India/9789354248429 , Digital Control/Moudgalya/Wiley India/9788126522064 , An Advanced Approach To Data Interpretation For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9358702330 , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9355012326 , Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9355011534 , Objective General English/R.S. Aggarwal/S Chand Publishing/978-9355015075 , The Magic Of The Lost Temple/Sudha Murty/Penguin Books India/978-0143333166 , Samsara: Enter The Valley Of The Gods/Saksham Garg/Penguin/978-0143458289 , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery/Brianna Wiest/Amaryllis/978-9355434142 , I Dont Love You Anymore: Moving On And Living Your Best Life/Rithvik Singh/Ebury Press/978-0143469131 , Ancient India/Rs Sharma/Old Ncert/N/A , History Of Medieval India/Satish Chandra/Old Ncert/N/A , A Brief History Of Modern India/Spectrum Publications/Spectrum/N/A , India’S Struggle For Independence/Bipan Chandra/Penguin/N/A , Certificate Physical And Human Geography/G.C. Leong/Oxford University Press/N/A , India: A Comprehensive Geography/D.R. Khullar/Kalyani Publishers/N/A , Indian Polity/M. Laxmikanth/Mcgraw Hill/N/A , Indian Economy/Ramesh Singh/Mcgraw Hill/N/A , Environment/Shankar Ias/Shankar Ias Academy/N/A , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/N/A , Disaster Management/R. Subramanian/Vikas Publishing/N/A , Internal Security/M.Karthikeyan/Tata Mcgraw Hill/N/A , Lexicon For Ethics, Integrity & Aptitude/Niraj Kumar/Pearson/N/A , Ethics, Integrity, And Aptitude/Subba Rao And P.N. Roy Chowdhury/Access Publishing/N/A , Principles Of Mathematical Analysis/Walter Rudin/Mcgraw-Hill Education/978-0070856134 , Real And Complex Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619876 , Functional Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619883 , Mathematical Analysis/Tom M. Apostol /Narosa/978-8185015668 , Real Analysis/Royden/Pearson Education India/978-9332551589 , Analysis I/Terence Tao/Hindustan Book Agency/978-9380250649 , Complex Analysis/Ahlfors L V/Mcgraw Hill/978-1259064821 , Complex Variables And Applications/James Ward Brown, Ruel V. Churchill/Mcgraw Hill/978-9354600364 , Functions Of One Complex Variable I/John B. Conway/Springer/978-0387903286 , Algebraic Topology/Allen Hatcher /Cambridge University Press/978-0521795401 , Topology/James Munkres/Pearson Education/978-9353432775 , Introduction To Topology And Modern Analysis /George Simmons/Mcgraw Hill Education/978-0070597846 , Introduction To Analytic Number Theory/Tom M. Apostol /Springer/978-1-4419-2805-4 , Topology Of Metric Spaces/S. Kumaresan/Narosa/978-81848705 , Topics In Algebra/I.N. Herstein/Wiley/978-8126510184 , Algebra/M Artin/Pearson Education India/978-9332549838 , Abstract Algebra/David S. Dummit, Richard M. Foote/Wiley/978-8126532285 , A First Course In Abstract Algebra/J.B. Fraleigh/Narosa Publishing House Pvt Ltd/978-8185015705 , Contemporary Abstract Algebra/Joseph A Gallian/Cengage India Private Limited/978-9353502522 , Linear Algebra/Kenneth M Hoffman And Ray Kunze/Prentice Hall India Learning Private Limited/978-9332550070 , Matrix Analysis/Roger A. Horn, Charles R. Johnson/Cambridge University Press/978-0521548236 , Topics In Matrix Analysis/Charles R. Johnson, Roger A. Horn/Cambridge University Press/978-0521467131 , Matrix Analysis/Rajendra Bhatia/Springer/978-0387948461 , Introduction To Linear Algebra/Gilbert Strang /Wellesley-Cambridge Press/978-09802327-7-6 , Linear Algebra And Learning From Data/Gilbert Strang/Wellesley-Cambridge Press/978-06921963-8-0 , Linear Algebra: A Geometric Approach/S. Kumaresan/Prentice Hall India Learning Private Limited/978-8120316287 , Differential Equations/Shepley L. Ross /Wiley/978-8126515370 , Theory Of Ordinary Differential Equations/Earl Coddington, Norman Levinson/Mcgraw Hill Education/978-0070992566 , Differential Equations: Theory - Technique And Practice /George Simmons/Mcgraw Hill Education/978-0070616097 , Introduction To Graph Theory/West/Pearson Education India/978-9332549654 , Graph Theory/Frank Harary/Narosa Publishing House/978-8185015552 , Spectral Graph Theory/Fan R. K. Chung/American Mathematical Society/978-0821803158 , Graphs And Matrices/Ravindra B. Bapat/Springer London Ltd/978-1848829800 , Spectra Of Graphs/Andries E. Brouwer, Willem H. Haemers/Springer/978-1489994332 , The Feynman Lectures On Physics Vol 3/Richard P. Feynman/Addison-Wesley/978-8185015842 , Quantum Computation And Quantum Information/M. A. Nielsen And I. L. Chuagn/Cambridge University Press/978-1107619197 , Principles Of Quantum Computation And Information: A Comprehensive Textbook/Giuliano Benenti, Giulio Casati/World Scientific Publishing Co Pte Ltd/978-9813279995 , Quantum Computing Explained/David Mcmahon/Wiley-Ieee Computer Society Pr/978-0470096994 , Coding Theory: A First Course/San Ling/Cambridge English/978-1108717540 , Elements Of Information Theory/Joy A. Thomas Thomas M. Cover/Wiley/978-8126541942 , First Course In Information Theory/Raymond W. Yeung/Springer Low Price Edition/978-8184897036 , Machine Learning: A Probabilistic Perspective/Kevin P. Murphy /The Mit Press/978-0262018029 , Introduction To Data Mining/Pang-Ning Tan Michael Steinbach Anuj Karpatne Vipin Kumar/Pearson/978-9354491047 , Data Warehousing: Fundamentals For It Professionals/Paulraj Ponniah/Wiley/978-8126537297 , An Introduction To Probability Theory And Its Applications Vol I/William Feller/Wiley/978-8126518050 , An Introduction To Probability Theory And Its Applications Vol Ii/William Feller/John Wiley & Sons Inc/978-8126518067 , A Textbook Of Algebra/Sudesh K Shah, Subhash Chand Garg/S.Chand/978-9352710829 , Introduction To Differential Geometry Of Space Curves And Surfaces/Taha Sochi/Create Space/1546735895 , Differential Geometry Of Manifolds/U. C. De, A. A. Shaiks/Narosa Publisher/ 978-8173197772 , Differential Geometry Of Manifolds/Lovett Stephen/Taylor & Francis Ltd/978-0367180461 , Adventures In Stochastic Processes/Sidney I. Resnick/Springer Science & Business Media/978-1461203872 , Statistical Methods/Kapil Sharma/Oxford Book Co./978-9350304693 , Statistics For Business And Economics/Dr. G.P. Yadav/Oxford Book Co./8185771545 , Statistics For Management /Ashish J. Dave/Oxford Book Co./978-9350300732 , Statistics For Management And Economics/Dr. G.P. Yadav/Oxford Book Co./978-8183765688 , Strategic Methods And Concepts Of Statistics/R.K. Jacob/Oxford Book Co./978-8183765800 , Vector Calculus/Dr. Rakesh Kumar Pandey/Oxford Book Co./978-9350304716 , A Course Of Mathematical Analysis/P K Mittal & /S.Chand/978-8121904728 , A Textbook Of Algebra/Subhash Chand Garg /S.Chand/978-9352710829 , A Textbook Of Discrete Mathematics/Dr. Swapan Kumar Sarkar/S.Chand/9788121922326 , A Textbook Of Vector Analysis/P K Mittal & /S.Chand/9788121922432 , A Textbook On Dynamics/M Ray & G C Sharma/S.Chand/9788121903424 , Advanced Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908931 , Analytical Solid Geometry/P K Mittal & Shanti Narayan/S.Chand/9788121926614 , Applied Mathematics/N C Srinivas & Ch V Ramana Murthy/S.Chand/9788121920827 , Differential Calculus/Shanti Narayan & P K Mittal/S.Chand/9788121904711 , Differential Calculus For Competetions/Shanti Narayan/S.Chand/978-8121925136 , Dynamics/Dr. M.D. Raisinghania/S.Chand/978-8121926492 , Elementary Statistics/H C Saxena/S.Chand/978-8121909259 , Elements Of Real Analysis/Dr. M.D. Raisinghania & Shanti Narayan/S.Chand/9788121903066 , Experimental Statistics/Dr. K. Balaji/S.Chand/9788121935661 , Fourier Series And Integral Transforms/Dr. V. Ramesh Babu & S. Ranganatham/S.Chand/9789384319090 , Integral Calculus/P K Mittal & Shanti Narayan/S.Chand/9788121906814 , Integral Calculus For Competetion/P K Mittal & Shanti Narayan/S.Chand/9788121925358 , Integral Equations And Boundary Value Problems/Dr. M.D. Raisinghania/S.Chand/9788121928052 , Mathematical Statistics/J. N. Kapur & H.C. Saxena/S.Chand/9788121912464 , Mathematics For Degree Students/Dr. U.S. Rana/S.Chand/9788121941013 , Algebraic Topology: An Introduction/Naseer Khan/Oxford Book Co./978-9350303344 , Analysis On Manifolds: A Modern Approach To Mathematics & Physics/V.G. Gupta/Oxford Book Co./978-9350304242 , Applied Combinatorics /Luis J. Green/Oxford Book Co./978-9350304556 , Applied Partial Differential Equations/Dr. F.D. Wade/Oxford Book Co./978-8189473433 , Applied Statistics For Economics And Business/G.P. Gupta/Oxford Book Co./978-9350303825 , Basics Of Bioinformatics/Narayan Dubey/Oxford Book Co./978-9383096893 , Business Statistics For International Trade/Ashish J. Dave/Oxford Book Co./978-9383101030 , Calculus For Computer Graphics/Gopal Narayan/Oxford Book Co./978-9383096916 , Calculus With Vectors/Luis J. Green/Oxford Book Co./978-9383096053 , Computing Fundamentals/Gopal Narayan/Oxford Book Co./978-9350304624 , Elementary Bioinformatics/Dr. Satish Kumar Sinha/Oxford Book Co./978-9350304266 , Environmental Statistics With R/Dr. Manendra Kumar/Oxford Book Co./978-9350301333 , Essential Statistics For Business And Economics/Ashish J. Dave/Oxford Book Co./978-9383096176 , Essentials Of Bioinformatics/Dr. Ashish Gulwe/Oxford Book Co./978-9350303603 , Fuzzy Logic, Neural Network And Genetic Algorithms Handbook/Jan Bundschuh/Oxford Book Co./978-9383096039 , Handbook Of Bioinformatics/S.G. Sandhu/Oxford Book Co./978-8193470404 , Mathematical Logic/Dr. Savita Mishra/Oxford Book Co./978-9350304532 , Mathematical Modelling/Naseer Khan/Oxford Book Co./978-9382629733 , Mathematical Physics/Hilary D. Brewster/Oxford Book Co./978-9350303412 , Optimization Theory: Techniques Of Operation Research/V.G. Gupta/Oxford Book Co./978-9350304334 , Mechanics/Muthamizh Jayapragasam, Laxmi Duraipandian/S.Chand/9788121902724 , Ordinary And Partial Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908924 , Probability And Quening Theory/P Kandasamy & /S.Chand/9788121923569 , Theory Of Functions Of A Complex Variable/P K Mittal & Shanti Narayan/S.Chand/9788121906395 , Vector Algebra/P K Mittal & Shanti Narayan/S.Chand/9788121909525 , Vector Analysis/Kayalal Pachaiyappa & P Duraipandian/S.Chand/9789384319694 , Statics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173810275 , Rigid Dynamics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173812248 , Higher Algebra[Classical And Modern]/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173811043 , Numerical Analysis With Elements Of Computer Science/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173817557 , Mathematical Analysis/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./978-8173817809 , Numerical Analysis/Kalyan Mukherjee/New Central Book Agency Pvt. Ltd./978-8173815201 , Linear Programming And Theory Of Games/Pyari Mohan Karak/New Central Book Agency Pvt. Ltd./978-8173814051 , Analytical Geometry And Vector Algebra/Ratan Mohan Khan/New Central Book Agency Pvt. Ltd./9788-173810169 , Analytical Dynamics Of A Particle Including Elements Of Statics/Shambhunath Ganguly/New Central Book Agency Pvt. Ltd./9788-173811630 , Differential Equations With Introduction To Laplace Transform/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173816635 , Numerical Methods Practical/Shyamapada Dutta/New Central Book Agency Pvt. Ltd./978-8173815645 , A First Course On Operations Research And Information Theory/Sanat Kumar Mazumder/New Central Book Agency Pvt. Ltd./978-8173818844 , Advanced Business Mathematics And Statistics/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173816741 , Engineering Mathematics/Rajkumar Roychoudhury/New Central Book Agency Pvt. Ltd./978-8173810909 , Analytical Dynamics Of A Particle/Sambhunath Ganguly/New Central Book Agency Pvt. Ltd./978-8173810497 , Integral Calculus/Kantish Ch Maity/New Central Book Agency Pvt. Ltd./97-88173817328 , Introduction To Number Theory/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97881-73815867 , Mathematics And Statistics/Suranjan Saha/New Central Book Agency Pvt. Ltd./97881-73811838 , Mathematical Probability/Kartick Chandra Pal/New Central Book Agency Pvt. Ltd./978-8173817816 , Differential Geometry/Fr F Goreux/New Central Book Agency Pvt. Ltd./978-8173815669 , Introduction To Tensor Calculus/Fr F Goreux/New Central Book Agency Pvt. Ltd./9788-173818516 , Vector Analysis Tensor Analysis And Linear Vector Space/S P Kuila/New Central Book Agency Pvt. Ltd./9789-352550333 , Introduction To Discrete Mathematics/M K Sen/New Central Book Agency Pvt. Ltd./97881-87134886 , Topics In Mathematics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134466 , Advanced Linear Programming & Game/A Mukherjee/New Central Book Agency Pvt. Ltd./97893-84294083 , Application Of Calculus/Debasish Sengupta/New Central Book Agency Pvt. Ltd./97881-87134626 , Analytical Statics/S A Mollah/New Central Book Agency Pvt. Ltd./97893-84294427 , Basic Concepts Of Numerical Methods, Probability And Statistics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134947 , Numerical Analysis And Computational Procedures/S A Mollah/New Central Book Agency Pvt. Ltd./97881-87134107 , An Introduction To Probability And Probability Distributions/Rajeshwar Singh/New Central Book Agency Pvt. Ltd./978938-4294175 , Dynamics Of Rigid Bodies/S A Mollah/New Central Book Agency Pvt. Ltd./978818-7134985 , Differential Geometry/M Majumdar/New Central Book Agency Pvt. Ltd./978938-4294144 , Advanced Higher Algebra/A N Das/New Central Book Agency Pvt. Ltd./978938-4294021 , Introduction To Abstract And Linear Algebra/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97893-52550586 , Design Of Experiments And Sampling Methods/K C Bhuyan/New Central Book Agency Pvt. Ltd./97893-52550234 , Engineering Mathematics/T Veerarajan/Mcgraw Hill Education/ 97-0071328777 , Engineering Mathematics Ii/T Veerarajan/Mcgraw Hill Education/978-9387432345 , Advanced Engineering Mathematics/Ravish R. Singh/Mcgraw Hill Education/97-89353161033 , Discrete Mathematics/T Veerarajan/Mcgraw Hill Education/978-9353161606 , Business Mathematics And Statistics/N G Das, J. K. Das/Mcgraw Hill Education/978-0071333399 , A First Course In Mathematics For Management/M. Raghavachari/Mcgraw Hill Education/978-0070965706 , Fundamentals Of Mathematical Analysis/G. Das, S. Pattanayak/Mcgraw Hill Education/978-0074515730 , Introduction To Linear Algebra With Applications/James Defranza, Daniel Gagliardi/Mcgraw Hill Education/978-1259025587 , Numerical Methods With Programs In C/T Veerarajan, T Ramachandran/Mcgraw Hill Education/978-0070601611 , Ordinary And Partial Differential Equations With Laplace Transforms, Fourier Series And Applications/V. Sundarapandian/Khanna Publishers/978-1259004568 , Higher Engineering Mathematics/B.S. Grewal/Khanna Publishers/978-81-933284-9-1 , Discrete Mathematics And Its Applications/A. Tamilarasi And A.M. Natarajan/Khanna Publishers/978-81-7409-151-2 , Functions Of Complex Variables/A.K. Mukhopadhyay/Khanna Publishers/N/A , Numerical Methods In Engineering & Science With Programs In C, C++ & Matlab/B.S. Grewal/Khanna Publishers/978-81-7409-248-9 , An Introduction To The Calculus Of Variation For Engineers And Economics/A.K. Mukhopadhyay/Khanna Publishers/978-81-7409-186-4 , Engineering Mathematics/Mukul Bhatt/Mcgraw Hill Education India Pvt. Ltd/9789390000000 , Convective Heat And Mass Transfer/Adrian Bejan/John Wiley And Sons/978-0-470-90037-6 , Perspective In Environmental Studies/Anubha Kaushik And C P Kaushik/New Age International Publishers/978-93-86418-63-0 , Engineering Mechanics (Statics And Dynamics)/Dr D S Kumar/S K Karatia And Sons/978-93-5014-292-9 , Fundamentals Of Acoustics/Lawrence E. Kinsler, Austin R. Frey, Alan B. Coppens, James V. Sanders/Wiley/978-0-471-84789-2 , Foundations Of Engineering Acoustics/Frank Fahy/Academic Press/Elsevier/978-0122476655 , The Theory Of Sound, Volume I/Lord Rayleigh & Robert B. Lindsay/Dover Publications Inc./978-0486602929 , Mechanical Vibration/S.S. Rao/Pearson Education India/978-8177588743 , Vector Mechanics For Engineers: Statics And Dynamics/Beer, Johnston, Cornw Ell& Sanghi/Mcgraw Hill Education/978-1259062919 , Entrepreneurship Development And Small Business Enterprises/Charantimath Poornima M./Pearson/9353066263 , Entrepreneurial Development/Khanka S.S./S Chand/8121918014 , Mechanical Vibrations/Debabrata Nag/Wiley/978-8126530908 , Design Of Machine Elements/Dr.G.K.Vijayaraghav An&Dr.S.Vishnupriyan/Laxmi Publications/8192048535 , Introduction To Dynamics/Amitabha Ghosh/Springer/978-981-10-6094-6 , Mechanics Of Laminated Composite Plates And Shells – Theory And Analysis/J.N. Reddy/Crc Press/978-0203502808 , Composites: Science And Technology/Dr. R. C. Prasad, Dr. P. Ramakrishnan/New Age International (P) Ltd., Publishers/978-8122412512 , Product Design And Development/Karl Ulrich, Steven Eppinger And Maria C. Yang/Mc Graw Hill/978-1260043655 , Mechatronics: Integrated Mechanical Electronic Systems/K.P. Ramachandran, G.K. Vijayaraghavan, M.S.Balasundaram/Wiley India/978-8126518371 , Groovers Principles Of Modern Manufacturing Si Version/Mikell P. Groover/Wiley India/978-8126573059 , Manufacturing Science : Metal Cutting, Conventional And Non-Conventional Machine, Welding, Volume - Ii/G.S. Sawhney/Wiley India/97-89389520408 , Project Planning And Control With Pert And Cpm/Dr. B.C. Punmia, K.K. Khandelwal/Laxmi Publications (P) Ltd/978-8131806982 , Cad/Cam Theory And Practice/Ibrahim Zeid, R Sivasubramanian/Mcgraw Hill Education/978-0070151345 , Optimization For Engineering Design/Kalyanmoy Deb/Prentice Hall India Learning Private Limited/978-8120346789 , Mechanical Vibrations /G Kgrover/Nem Chand And Brothers /978-81-85240-56-5 , Tribology: Friction And Wear Of Engineering Materials /Ian Hutchings And Philip Shipway/Elsevier/978-0-08-100910-9 , Business Statistics: Text And Problems - With Introduction To Business Analytics/Nd Vohra/?Mcgraw Hill Education /978-9390727063 , Statistics For Management/Richard I. Levin, Masood H. Siddiqui, David S. Rubin, Sanjay Rastogi, /?Pearson Education/978-8184957495 , Financial Accounting/Sn Maheshwari, Suneel K Maheshwari,Sharad K Maheswari/?Vikas Publishing House/978-9352718535 , Management Accounting Principles & Practice/Shashi K. Gupta , R.K. Sharma, Neeti Gupta /Kalyani Publishers/N/A , Organizational Behaviour /Stephen P. Robbins, Timothy A. Judge , Neharika Vohra/?Pearson Education/978-9356064270 , Organisational Behaviour: Text, Cases & Games/K. Aswathappa/Himalaya Publishing House/978-93-5693-187-9 , Modern Microeconomics /A. Koustsoyiannis/?Palgrave Macmillan;/978-0333253496 , Business Law /Nd Kapoor /?Sultan Chand And Sons /978-9389174106 , Marketing Management /Phillip Kotler /?Pearson Education/978-9356062665 , Dominic Salvatore International Economics /Chandan Sharma /Wiley /978- 9354247170 , International Business /Charles W .L .Hill/?Mcgraw Hill/978-9355324771 , Strategic Management ( Concept & Cases )/Fred R David , Forest R David/Pearson Education/978-9332548930 , Production And Operations Management/Sn Chary/Mcgraw Hill/978-9353164812 , Production And Operations Management/E Anil Kumar , N Suresh/New Age International/978-8122421774 , E Commerce /Kenneth C. Laudon , Carol Guercio Traver/?Pearson Education/978-9356060647 , Entrepreneurship /Arya Kumar/Pearson Education /978-8131765784 , Corporate Finance /Ross , Westerfield ,Jaffe , Jordan /Mcgraw Hill /978-9390727926 , Security Analysis And Portfolio Management /Donald E. Fisher, Ronald J. Jordan, A.K . Pradhan /Pearson Education /978-9353066284 , Investment Analysis And Portfolio Management |/Prasanna Chandra /Mcgraw Hill /978-9354600074 , Advertising And Sales Promotion/Shh Kazmi, Satish Batra/Excel Books/978-8174466396 , Advertising And Sales Promotion ( An Integrated Marketing Communications Perspective)/George E Belch, , Michael A Belch, Keyoor Purani/Mcgraw Hill /978-9354600807 , Strategic Brand Management/Kevin Lane Keller , Vanitha Swaminathan, Ambi Mg Parameswaran , Issac C Jacob /Pearson Education /978-9353946135 , Human Resource Management: Text And Cases/ K. Aswathappa , Sadhna Dash/Mcgraw Hill /978-9355323675 , Managerial Economics And Business Strategy/Micheal R. Baye , Jeffery T . Prince/Mcgraw Hill/978-9354600203 , Intellectual Property Law/Avtar Singh/Eastern Book Company/978-9350289853 , Law Relating To Intellectual Property Rights/V K Ahuja/Lexis Nexis/978-8131251652 , Intellectual Property Rights Manual/Sumeet Malik/Eastern Book Company/978-9351452300 , Law Relating To Intellectual Property/Dr. B.L. Wadehra/Universal Law Publishing/978-9350350300 , Consumer Behavior/Kumar Leon G., Schiffman;Joe, Wisenblit;S. Ramesh/Pearson Education/978-9353069834 , Purchasing And Inventory Control/K S Menon And Sarita Kulkarni/ Shroff Publishers/978-8184047066 , Production Systems: Planning, Analysis, And Control/James L. Riggs /? John Wiley & Sons/? 978-0471847939 , A Textbook Ofmanufacturing Technology (Manufacturing Processes)/R K Rajput/ Laxmi Publications/? 978-8131802441 , A Textbook Of Material Science And Metallurgy /O P Khanna/Dhanpat Rai /978-8189928315 , Atomic Physics/Max Born (Author) , J. M. Radcliffe (Translated) R. J. B-. Stoyle (Translated)/Dover Publications/978-0486659848 , Concepts Of Atomic Physics/S P Kuila /New Central Book Agency (Ncba)/978-9352550838 , Fundamentals Of Molecular Spectroscopy/Banwell/Mcgraw Hill Education/978-9352601738 , Introduction To Nuclear And Particle Physics/V.K. Mittal, R.C. Verma, S.C. Gupta /Phi Learning/978-9387472617 , Concepts Ofnuclear Physics/Bernard Cohen/Mcgraw Hill Education/978-0070992498 , Nuclear And Particle Physics: An Introduction/B.R. Martin/Wiley/978-8126565078 , Introduction To Elementary Particle Physics/Alessandro Bettini/Cambridge University Press/978-1107050402 , Solid State Physics/Ashcroft, Mermin/Cengage Learning/978-8131500521 , Physics Of Semiconductor Devices/S.M. Sze, Kwok K. Ng /Wiley/978-8126517022 , Semiconductor Physics And Devices (Sie)/Donald Neamen (Author), Dhrubes Biswas/Mcgraw Hill Education/978-0071070102 , Liquid Crystal Sensors/Albert Schenning (Editor), Gregory P. Crawford (Editor), Dirk J. Broer (Editor)/Crc Press/978-1498729727 , Liquid Crystals: Experimental Study Of Physical Properties And Phase Transitions/Satyendra Kumar/Cambridge University Press/978-0521187947 , Liquid Crystals I/M.A. Athanassopoulou, M.A. Bates, Et Al./Springer/978-3662147160 , Dielectric Effect In The Isotropic Phase Of Liquid Crystal Materials/Mukherjee Prabir,Drozd-Rzoska Aleksandra,Rzoska Sylwester/Lambert Academic Publishing,/9783660000000 , Nanoscience With Liquid Crystals: From Self-Organized Nanostructures To Application/Quan Li/Springer/978-3319377124 , Fundamentals Of Mathematical Physics/A. B. Gupta/Books & Allied (P) Ltd/81-87134-23-2 , Higher Mathematical Physics/H. K. Das And Dr Rama Verma/S. Chand & Company Pvt. Ltd/978-93-83746-77-4 , Head Thermodynamics And Statistical Physics/Brij Lal, N. Subrahmanyam And P. S. Hemne/S. Chand & Company Pvt. Ltd/81-219-2813-3 , The Physics Of Solar Cells : Perovskites, Organics, And Photovoltaic Fundamentals/Juan Bisquert/Crc Press/9781138099968 , Nanomaterials And Nanocomposites: Synthesis, Properties, Characterization Techniques, And Applications/Rajendra Kumar Goyal/Crc Press/9781498761666 , Callisters Materials Science And Engineering./Balasubramaniam/Wiley India/9788126541607 , Introduction To Physics /Cutnell/Wiley India/9788126556021 , Physics, Vol 1, 5Ed , An Indian Adaptation /Halliday/Wiley India/9789354640384 , Physics, Vol 2, 5Ed, An Indian Adaptation /Halliday/Wiley India/9789354640438 , Principles Of Physics, 10Ed/Halliday/Wiley India/9788126552566 , Statistical Mechanics, 2Ed, An Indian Adaptation/Huang/Wiley India/9789354247736 , Classical Electrodynamics, An Indian Adaptation /Jackson/Wiley India/9789388991070 , Kittels Introduction To Solid State Physics, Wiley India Edition/Kittel/Wiley India/9788126578436 , Modern Physics, 4Ed, An Indian Adaptation /Krane/Wiley India/9789354244681 , Material Science: Nanotechnology And Applications /Kumar/Wiley India/9789390455317 , Introduction To Nanoscience And Nanotechnology, An Indian Adaptation /Poole/Wiley India/9789354240201 , Applied Solid State Physics/Rajnikant/Wiley India/9789354643309 , A Textbook Of Astronomy And Astrophysics /Sharma/Wiley India/9789389520903 , Tensors: Concepts And Applications With Scilab Programs/Soni /Wiley India/9789389633207 , Engineering Physics, As Per Aicte /Wiley Editorial Team/Wiley India/9788126521418 , A Textbook Of Applied Physics, Vol I/Jha/Wiley India/9789389307405 , A Textbook Of Applied Physics, Vol Ii/Jha/Wiley India/9789389520453 , Mathematical Methods In The Physical Sciences, 3Ed, An Indian Adaptation /Boas/Wiley India/9789354644252 , Fundamentals Of Fluid Mechanics/Sawhney/Wiley India/9789389698008 , Quantum Mechanics Concepts And Applications/Nouredine Zettili/Wiley India/978-0-470-02678-6 , Introductory Nuclear Physics/S. Krane Kenneth/Wiley India/978-8126517855 , Principles And Applications Of Ferroelectrics And Related Materials/M. E. Lines And A. M. Glass/Oxford University Press/978-0198507789 , A Modern Introduction To Quantum Field Theory/Michele Maggiore/Oxford University Press/978-0198520740 , The Physics Of Solids/J. B. Ketterson/Oxford University Press/978-0198742906 , Introduction To Spintronics/Supriyo Bandyopadhyay/Routledge/978-0367656447 , Perovskite Metal Oxide/Moharana/Elsevier/9780320000000 , Materials Characterization Techniques/Lin Li, Sam Zhang,Ashok Kumar/Crc Press/?978-1032064208 , Magnetic Measurement Techniques For Materials Characterization/Victorino Franco/Springer/978-3030704452 , Indentation Techniques In Ceramic Materials Characterization: Theory And Practice/Ahmad G.Solomah/Ceramics Transaction/978-1574982121 , Element Of X-Ray Diffraction/B D Cullity/Pearson Education India/9789332535169 , Introduction To Magnetic Materials/B D Cullity/Wiley-Ieee Press/978-0471477419 , Symmetry And Spectroscopy: An Introduction To Vibrational And Electronic Spectroscopy/Daniel C Harris/Dover Pubns/978-0486661445 , The Spectra And Structures Of Simple Free Radicals: Introduction To Molecular Spectroscopy/Gerhard Herzberg/Dover Pubns/978-0486658216 , An Introduction To Practical Infra-Red Spectroscopy/A D Cross/Dover Pubns/978-1489962744 , Handbook On The Physics And Chemistry Of Rare Earths: Optical Spectroscopy/Karl A.Gschneidner/North-Holland/978-0444521446 , Molecular Spectroscopy/Jackd.Graybeal/Mcgraw-Hill Education(Ise Edition)/978-0070243910 , Fundamentals Of Statistical And Thermal Physics/Frederick Reif/Sarat Book Distributors/9789380663142 , Thermodynamics And An Introduction To Thermostatistics/H. B. Callen/John Wiley & Sons Inc/9780471862567 , Introduction To Phase Transitions And Critical Phenomenon (International Series Of Monographs On Physics)/H. E. Stanley/Oxford University Press/9780195053166 , A Guide To Monte Carlo Simulations In Statistical Physics/David P. Landau And Kurt Binder/? Cambridge University Press;/9781139696463 , Statistical Mechanics/R. K. Pathria/Elsevier/9789351073970 , Computational Methods In Physics And Engineering/Samuel S M Wong/World Scientific/9810230435 , Mathematical Methods Of Physics/Jon Mathews And Robert L. Walker/?Pearson Addison-Wesley/805370021 , A Text Book Of Integrated Engineering Physics /Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-81-906486-1-5 , A Text Book Of Basic Engineering Physics/Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-8190648615
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
47.
Public Administrative Department #9331376 Price Bid
Tender For Biomining At Ward No.9, Burial Groundarea In Othakkalmandapam Town Panchayat.; (a) Excavation the existing mixed compacted Garbage which underwent biological degradation in the land portion allocated / earmarked by Sarkarsamakulam Town Panchayat Compost Yard and spraying with microbial innoculam for sanitizing and stabilizing the excavated mass sieving them using Mechanical Seiving machine or any other equipment at the cost of the Bidder(b) Control of mal odour using Deodorizing agent and stabilizing the waste using Bio Culture for aerobic composting using industrial sprayer Eco friendly and non pollution process in order to reduce the impact of dumping site in the adjacent areasSegregate the excavated garbage in the land portion earmarked, into as many kind and categories as possible at the cost of the Bidder including cost of any power or fuel consumptionSelling, diverting for recycling marketing and recycling the excavated materialsCleanly rehanded over the site including clean removal of any residue from the site including conveyance away from the Sarkarsamakulam Town Panchayat limit and handling ovet the earmarked site by the Town Panchayat including cost and conveyance and handling labour charges etc completeCreation and maintenance of infrastructure facilities and amenities at Bidder’s risk and cost, for sieving, the excavated garbage, storing the segregation materials Deployment of necessary manpower, materials, equipments tools and construction of plants and sheds and creation of facilities for handling, separating, segregation and storing for the operation of the plantLeveling the earth surface by bull-dozer or any other earth moving equipmentProviding security arrangement for the plan project site, machineries, equipment etc, at the cost of the Bidder
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
49.
Housing Urban and Rular Development #9320996 Technical Bid
Tender For Deepening & Strengthening Of Mandaikulamoorani With Construction Of Bathing Ghat At Mettupattipanchayat H/O Mettupatti.; 2 Cleaning light Jungle (based on standardschedule of rates vid., S.no W0002 3 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete W 0085 4 Main pond 5 Baby pond 6 Lead Channel 7 CIVIL WORK 8 Earth work excavating and depositing on bank with an initial lead of 10M and initial lift of 2m in hard stiff clay stiff block cotton, hard red earth shales, murrams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil SS 20B for foundation 9 Supplying and filling with Sand for foundation and basement layers of not more than 15 cm thick well rammed andwatering Complying with standard specification 10 Cement concrete for foundation 1:4:8 using 40mm HBGS jelly including all incidental charges such as bailing out waterfinishing curing complete complying with standard specification 11 Supplying and erecting centering shuttering including necessary supports for plane surface in foundation andbasement and in all floors for RCC column footing column plinth beam, beams, roof slabs, staircase steps, bed blocks,critical pier etc 12 Cement concrete for Bathing ghat inner portion 1:2:4 using 20mm HBGS jelly including all incidental charges such asbailing out water finishing curing complete complying with standard specificatio 13 Supplying & Fabrication laying in position of mild steel TOR grils for RCC works including cost and conveyance etc., 14 Reinforced Cement concrete for Bathing ghat OUTER BEAM reinforcement portion 1:2:4 using 20mm HBGS jellyincluding all incidental charges such as bailing out water finishing curing complete complying with standardspecification 15 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package} 16 2. Deepening of Karuppakoundar Thaottakulam at Chinnaiyagoundenpudur H/OMettupatti.Estimate Amount Rs.3.10 Lakhs 17 Cleaning light Jungle (based on standardschedule of rates vid., S.no W0002 18 Earth work in all soils except hard rock requiring blasting and conveying for formation of bund with lead of 0 to 100 metre deploying earth moving machinery and tippers including benching, formation of bunds, breaking clods, sectioning etc., complete W 0085 19 Main pond 20 Baby pond 21 Lead Channel 22 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package} 23 3.Construction of Threshing floor at Chinnaiyagoundenpudur H/O Mettupatty . Estimate Amount Rs.9.21 Lakhs 24 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 25 Cement Concrete 1:4:8 (One Cement, Four sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 26 Supplying and erecting centering for sides & soffits including supports and strutting up to 3.29m height for plane surfaces in all floors with all cross bracing using mild steel sheets of size 90cm x 60cm and 10 gauge stiffened welded with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over country wood poists of size 10cm x 6.5cm dia spaced at about 90cm center to center etc., complete 27 Cement Concrete 1:3:6 (One Cement, Three sand and six hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 28 Brick work in Cement Mortar1:5 (one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4for foundation and basement including curing, etc., complete complying with standard specifiction. 29 Reilling the excavated earth other than sand including cost,conveyance and filling charges etc.,as per standard specifications 30 Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 31 Cement Concrete 1:2:4 (One Cement, Two sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 32 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 33 Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. 34 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and approved colour over a priming coat including through scrapping, clean removal of dirt and including necessary plaster of pairs putty, wherever required etc complete complying with standard specification 35 Supplying and fixing of 0.47mm thick Gulvalume sheetfor roofing including all labour charges for fixing neccesary bolt, nuts, screws, J or U bolts etc, 36 Rafter - 25 mm x 25 mm M.S. Square Tubular Hollow pipe of 2.60 mm thick 37 Supply and fixing of Bitumen pad including cost and conveyance and all labour charges etc.complete 38 Towards the cost of Providing Name boardincluding cost and conveyance of all materials and all labour charges etc.,complete 39 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package} 40 4.Construction of Threshing floor at Perumalnaickenvalasu H/O Mettupatty .Estimate Amount Rs.9.21 Lakhs 41 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 42 Cement Concrete 1:4:8 (One Cement, Four sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 43 Supplying and erecting centering for sides & soffits including supports and strutting up to 3.29m height for plane surfaces in all floors with all cross bracing using mild steel sheets of size 90cm x 60cm and 10 gauge stiffened welded with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over country wood poists of size 10cm x 6.5cm dia spaced at about 90cm center to center etc., complete 44 Cement Concrete 1:3:6 (One Cement, Three sand and six hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 45 Brick work in Cement Mortar1:5 (one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4for foundation and basement including curing, etc., complete complying with standard specifiction. 46 Reilling the excavated earth other than sand including cost,conveyance and filling charges etc.,as per standard specifications 47 Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 48 Cement Concrete 1:2:4 (One Cement, Two sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 49 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 50 Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. 51 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and approved colour over a priming coat including through scrapping, clean removal of dirt and including necessary plaster of pairs putty, wherever required etc complete complying with standard specification 52 Supplying and fixing of 0.47mm thick Gulvalume sheetfor roofing including all labour charges for fixing neccesary bolt, nuts, screws, J or U bolts etc, 53 Rafter - 25 mm x 25 mm M.S. Square Tubular Hollow pipe of 2.60 mm thick 54 Supply and fixing of Bitumen pad including cost and conveyance and all labour charges etc.complete 55 Towards the cost of Providing Name boardincluding cost and conveyance of all materials and all labour charges etc.,complete 56 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package} 57 5.Construction of Threshing floor at Mettupatty AD Colony H/O Mettupatty.Estimate Amount Rs.9.21 Lakhs 58 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 59 Cement Concrete 1:4:8 (One Cement, Four sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 60 Supplying and erecting centering for sides & soffits including supports and strutting up to 3.29m height for plane surfaces in all floors with all cross bracing using mild steel sheets of size 90cm x 60cm and 10 gauge stiffened welded with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over country wood poists of size 10cm x 6.5cm dia spaced at about 90cm center to center etc., complete 61 Cement Concrete 1:3:6 (One Cement, Three sand and six hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 62 Brick work in Cement Mortar1:5 (one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4for foundation and basement including curing, etc., complete complying with standard specifiction. 63 Reilling the excavated earth other than sand including cost,conveyance and filling charges etc.,as per standard specifications 64 Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 65 Cement Concrete 1:2:4 (One Cement, Two sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 66 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 67 Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. 68 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and approved colour over a priming coat including through scrapping, clean removal of dirt and including necessary plaster of pairs putty, wherever required etc complete complying with standard specification 69 Supplying and fixing of 0.47mm thick Gulvalume sheetfor roofing including all labour charges for fixing neccesary bolt, nuts, screws, J or U bolts etc, 70 Rafter - 25 mm x 25 mm M.S. Square Tubular Hollow pipe of 2.60 mm thick 71 Supply and fixing of Bitumen pad including cost and conveyance and all labour charges etc.complete 72 Towards the cost of Providing Name boardincluding cost and conveyance of all materials and all labour charges etc.,complete 73 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
50.
Heavy Industries and Public Enterprises #9237762 AOC
Tender For Periodical Services To General Assembly Shop-I And Hull Shop-I At New Facility At Hvf Avadi.; 1 Trimming of Tree branches all around the building and disposing the cutted branches without damaging existing roof, wall etc., to a lead exceeding 1 km from the site and dumping the same including clearing the cutted site from any cutted branch/ tree debris. The cost also includes use of safety aspects required at site. 2 Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting outin hard / dense soil for a width of 3 m from the shop wall to remove all the earth on the wall portion to ensure the full painting of the wall including spreading and levelling the excavated earth in the nearny sorrounding low lying areas 3 Hacking out plastering 15 cm vide on either side of the crack cutting of 6mm V groove by inserting chicken mesh in the gaps of wall and applying pressure grouting the cracks withPU filler material of reputed companies such as Master Builder solution, Fosroc, Alchemica, Dr Fixit, or equivalent make and finishing to the original shape as directed. The Crack filling shall be carried out as per the OEM specifcations specified by the OEM and the materialto be used shall be of freshly manufactured having a miminum life span of six months when brought ot site. 4 Taking down plastering on cement or cement lime plaster any description as directed. 5 Demolition of Reinforced Cement Concrete structure of any description. 6 Supply and fixing of Wire netting of galvanised steel wire 0.91mm dia fixed with tinned tacks of wire staplessize of mesh will be 12mm. 7 M & L for Dubbing in CM 1:6. 10mm thick on faces of old brick work and concrete surfaces. 8 Material and labour for plastering in cm 1:4 15 mm thick on fair faces of brick work and cement concrete surfaces. 9 Material and labour for plastering in cm 1:3 for 12 mm thick on fair faces of cement concreteceiling surfaces. 10 Forming jambs using CM 1:4to openings (to foregoing item), including cutting,toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete. 11 Material and labour for Providing, cement concreteType B 0 1:2:4 using 12.5 mm graded aggregate in lintels, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly roundedor chamfered angles and throating, as directed 12 Material and labour for Reinforced cement concrete (nominal mix) Type B0 1:2:4 (12.5mm graded) in Chajjas 13 Material and labour for Formwork to chullah hoods, chajjas, troughs and similar items including edge including fair flat finished surface. 14 M & L for Brick work built inCM.1:6 using Sub-Class “B” Bricks. 15 Supply and fixing of TMT MS Bars 10mm dia and over, cut to length bent to shape required including cranking, bending, spiraling for hoping for columns, hooking ends and binding with MS Wire not less than 0.9mm dia or securing with clips. 16 Material and labour for TMT mild steel bars 8 mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securing with clips 17 Complete removal of existing any type of treatment ( White wash / OBD /Cement paint / Synthetic enamel paint/ Aluminium paint/ polish) from walls surface till the complete exposure of old plastering surfaces are exposed. The contractor shall only use mechanized equipment while complete removal inside the office room and shop walls. The dust enamating while complete removal shall be cleaned on daily basis so that no hindarence to production shall happen in shop floor and office area. The surface shall be fully scrubbed to have a uniform and levelled surfaces, The safety equipments requirements for the worker working shall be the responsiblity of the contractor.The rate is inclusive of covering of alltheequipments in the office floor to protect from the dust particles using new taurpaulin sheets wherever required. 18 Material and labour for applying one coat of wall primer forexterior / Interior as required at site all complete Including preparation ofcomplete removal surfaces and new puttysurfaces. The primer to be used shall be seperate for the interior walls and exterior walls. The primer to be used will depend on the recommendation by the manufacturer for the type of interior emulsion and exterior emulsion to be used as specifiedin the item No: 20 and 24 The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC. 19 M & L for applying 3mm thick wall care putty on wall surfaces the putty to be applied in layers as recommended by the manufacturer and aslo as per the SSR part - 1 specifcations all as specified and directed by EIC. The putty to be used shall be of Asian paints ( Truecare wall putty), Berger paints (Bison wall putty). Nerolac paints (Nerolac cement putty), Birla wall care putty, JK wall putty or suitably equivalent. 20 M& L for applying two coats of white washing on ceilings surfaces including preparation of old ceiling surfaces complete all as specifiedand directedby EIC. 21 M&L for applying two coats of plastic emulsionon internal wall surfaces including preparaition of old wall surfaces complete all as directed. The interior Emulsion shall be of premium interior emulsionmanufacurured by reputed companies such as Asian paints (premium emulsion or apcolite supremapremium Emulsion) , Berger paints (Rangoli) Nerolac paints (Beauty Gold) or suitably equivalent. The brands shall be got approved by EIC. 22 Material and Labour for painting of steel surfaces with two coats of synethic enamel paintinculding preparation of oldsteel painted surfaces. The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 23 Material and Labour for painting of wooden surfaces with two coats of synethic enamel paintinculding preparation of oldwoodensurfaces The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC. 24 M & L for french polishing one or more coat on old surfaces of any description , width or girth including cleaning and preparing the old polshed surface to receive the new coats.The Material tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 25 Material and labour for applying two coats of exterior emulsion on external wall surfaces all complete Including preparation of old untreated surfaces. The Exterior emulsion to be used shall be ofAsian paints (Apex Ultima supreme or Apex ultima) Berger paints (weather coat all guard) Nerolac paints (Excel total) or suitably equivalent. The brands shall be got approved by EIC The Contractor shall give the guarantee as specified by the paint companies for their above exterior emulsion product. 26 Material and labour for painting surfaces of any description, over 10cm in width or girth, on structural steel surfaces like purlin trusses, open gantry girders and stanchions etc.,with one coat of aluminium paint including prepartation of old surfaces as specified and as directed. Protective measure (As per MES Part-I spec point 15.10.3) Surfaces of doors, windows, floors, articles of furniture, machineries etc., and such other parts of the building not to be treated shall be protected by using new taurpaulin sheets to avoid the paint drops , dust on the machines and shop floor from being splashed upon. Such surfaces shall be cleaned of splashes of white wash, colour wash, distemper, aluminium/synthetic enamel paint etc. The contractor shall be responsible for any damage to the fittings, fixture and furniture etc., The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 27 Material and labour for painting surfaces of any description, n exc 10cm in width or girth, on structural steel surfaces like purlin trusses, open gantry girders and stanchions etc.,with one coat of aluminium paint including prepartation of old surfaces as specified and as directed Protective measure (As per MES Part-I spec point 15.10.3) Surfaces of doors, windows, floors, articles of furniture, machineries etc., and such other parts of the building not to be treated shall be protected by using new taurpaulin sheets to avoid the paint drops , dust on the machines and shop floor from being splashed upon. Such surfaces shall be cleaned of splashes of white wash, colour wash, distemper, aluminium/synthetic enamel paint etc. The contractor shall be responsible for any damage to the fittings, fixture and furniture etc., The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 28 Supply ofarticulating hydraulicboom lift which can reach up to the height of15 to 25 metres height self moving type including necessary diesel for operating the articulated boom liftincluding a operator who will operate the articulated boom lift.The boomlift shall be used only for ensuring safety aspects at site like tying of net ,tying of life line, boom lift timings hour shall be counted from srart of the safety related work at site to completion of the safety related work for a particular day. 29 Repairing of existing steel windows shutter of any size and any no of shutterswhich are hanging from position by cutting the old ones and refabricatingthe hinges to suit the existing frame including repairing of window frame / sash bars if any required 30 Repairing of existing Aluminiumwindows shutter of any size and any number of shutterswhich are hanging from position by cutting the old ones and refabricatingthe hinges to suit the existing frame including repairing of window frame / sash bars if any required 31 Material and labour for paintingtwo coats of White Emulsion paint on old false ceiling board by removing all the board from the position without disturbing any of the Aluminium section and stacking neatly, cleaning the board from dustand painting two coats of white permium emulsion after giving recommended interval for curing as suggested by the Manufacturer and allowing to dry completely and refixing the boards tot he false ceiling and securing as required. 32 Material and labour for paintingtwo coats of White Synthetic enamel paint on old false ceiling board by removing all the board from the position without disturbing any of the Aluminium section and stacking neatly, cleaning the board from dustand painting two coats of white permium emulsion after giving recommended interval for curing as suggested by the Manufacturer and allowing to dry completely and refixing the boards tot he false ceiling and securing as required. 33 Supply and fixing of structuralmild steelsuch as ISA MS plates of Fe 410 W (grade E 250) - A Quality of any sizefor the damaged door welding and making good 34 Material and labour for painting red oxide primer / zinc chromate primer on new/ old steel surfaces including preparaiton of new steel surfaces not exceeding 10CM in width or girth. The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 35 Material and labour for painting red oxide primer / zinc chromite primer on new/ old steel surfaces including preparaiton of new steel surfaces over 10CM in width.The paint tobe used shall be ofAsian paints, Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC 36 Supply and fixing sheet glass ordinary quality of 4.00mm thick and glazing with oil putty in square not exc. 0.5 Sq.m in each paneincluding removal of damaged glass from position and refixing the aluminium clamps / beading, the rate is inclusive of replacement of damaged aluminum beading if any and making good. 37 Supply and fixing of rough cast wired glass 6.4 mm thick and glazing with oil putty by removing the aluminium beading and refixing after the fixing of new glass in square not exc 0.5 Sq.m in each pane . 38 Material and labour for one coat of damp block paint on wall surfacesto arrest dampness on the wall srfaces after preparing the old wall surfaces. The paint tobe used shall be ofAsian paints , Berger paints, Nerolac paints or suitably equivalent. The brands shall be got approved by EIC. 39 Removal of demolished debris / rocks to a lead exceeding 1.50 km but not exceeding 5 km and depositing where directed. 40 Material and labour for Writing letters/stencil writing (Building Nos) or letters, Figures (of any type and not exceeding 30 cm high with fluorescent paint complete all as directed by EIC.The Contractor shall note down all the letters before painting and shall rewrite the same in the old locations.
Contract Date: Feb 04, 2026 Contract Value : 2.32 Crore
Government Departments No of Bidders 3
TenderDetail
Loading tenders