View Bid Results For Earth Leakage Relay Tenders

We found 1141 Bid Results related to earth leakage relay tenders. You can find Contractor details who won earth leakage relay tenders along with contract details in Bid awards announcements section.

Filters
Stage
1009
86
46
Tender Publishing Platform
452
689
State / UT
30
238
151
138
112
104
89
42
41
33
31
28
18
15
14
13
12
11
8
7
6
6
6
5
4
3
2
1
1
1
1
Contract Value
183
502
394
59
Publish Date
1
0
0
0
0
Sector
23
697
162
60
46
44
24
23
17
16
9
8
7
7
5
4
3
2
2
1
1
1
1
1
Ownership
5
593
255
242
50
1
Within keyword
Active filters:
Showing 1–23 of 1141 tenders matching your filters
1.
Coal and Mines #11484435 AOC
Tender for A) Kilburn Make 100Amp, 550V, Ocb Sl. No. 9471 Start Delta Starter At Manberia Filter Plant, Victoria West Colliery , New Supply Of Earth Leakage Relay With Cbt And Ct , Supply Of Fixed Contacts With Holder , Sply Of Main Contacts & Finger Contacts , Supply Of Isolator Unit Complete Set , Ammeter, Voltmeter, Amps Selector, Volt Selector, Fuse Carrier, Push Switch Lamp Etc. , Supply Of Moving Contacts With Holder , Supply Of Copper Make Busbar , Copper Stud With 70Sqmm Lead , Overload Coil With Plunger , Supply Of Wiring Wire, Denting, Paint, Painting, Missing And Damaged Nut-Bolt, Washer Etc. , Labour Charges For Complete Overhauling, Fittings Of All Parts Cleaning And Testing. , A) Kilburn Make 100Amp, 550V, Ocb Sl. No. 9471 Start Delta Starter At Manberia Filter Plant, Victoria West Colliery , Supply & Fitting Of Ammeter, Volt Meter, A/S, V/Selector Switch, Push Switch, T.T. Etc. , New Supply & Fixing Of Earth Leakage Relay With Cbt , Supply & Fitting Of Fixed Holder , Supply & Fitting Of Fixed Contacts , Supply & Fitting Of Moving Contacts , Supply & Fitting Of Ct , Supply & Fitting Of Pilour Copper Busbar 3 Pcs. With Insulating , Supply & Fitting Of Bakelite Board , Supply & Fitting Of O/L Set , Supply & Fitting Of No Volt Set , Supply & Fitting Of Short Jumper , Supply & Fitting Of Auxiliary Pin Socket , Supply & Fitting Of Hrc Fush Carrier And completion Wiring Of Safety Circuit With Supply Of 2.5 Sqmm Pvc Wire Ferrule Tapes, Etc. , Labour Charges For Complete Overhauling, Testing & Fittings Of All Parts , Total Impact Of Gst For The Purpose Of Ctc
Contract Date: Jul 02, 2026 Contract Value : 1.02 Lakh
Boards / Undertakings / PSU No of Bidders 3
West Bengal View Result →
3.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
7.
Power #11308380 Technical Bid
procurement of electrical spares and consumables for 220 kv & 33kv switch yard at khodri power station, khodri , 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge. , 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 µs) 100 ka, rated lightning impulse withstand voltage 1.2/50µs - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge. , auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker. , surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd. , 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge. , 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge , control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker. , auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker. , auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator. , 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker. , rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator , mcb (2 pole,3a, 220v, dc ) , over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker. , 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample) , epoxy bushing/ fixed contact of r,y &b phase bottom side for 33kv cgl make panel (as per sample) , epoxy bushing/ fixed contact r,y &b phase top side for 33kv cgl make panel (as per sample) , ratech wheel of 33kv sf6 breaker, cgl make , flexible contact of 33kv sf6 breaker finger, cgl make (as per sample) , silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton , heat shrinkable cable terminal kit for 3-ø 400mm² ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons). , heat shrinkable cable terminal kit for 3-ø 400mm² ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons). , heat shrinkable cable terminal kit for 3-ø 185 mm² 33 kv xlpe cable for indoor application (make 3m/raychem/ densons). , heat shrinkable cable terminal kit for 3-ø, 185 mm² 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons). , p g clamp deer/panther for 220 kv conductor , p g tclamp deer/ zebra, for 220 kv conductor , p g clamp deer/ trantulla for 220 kv conductor , p g clamp tarantula/ trantulla for 220 kv conductor , p g clamp deer/deer for 220 kv conductor , p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - nut, 20 cm slot, up to 128 gb, ir range 30 meters, ip 66 & poe, (2 megapixel ir night vision bullet camera)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
8.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
9.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Jun 24, 2026 Contract Value : 16.78 Lakh
Government Departments No of Bidders 1
11.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
13.
Power #11237449 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Residential; 2755929; Service Provider - Operation And Maintenance Of Water Treatment Plant Having One Flash Mixer With Agitator And Clarification Tank Having Rotating Bridge, Two Filter Beds, One Chemical House Having Two Alum Solution Tanks With Agitator, 132 Kl Overhead Tank, One Sump Well And Its Pumps Motor Filter Water Sump And 1To 3 Nos Pumps And Motor Upto 30 Hp, 2 Nos Pumps And Motor Upto 60Hp, And All Other Accessories Including Cleaning Of Clarification Tank , Filter Water Reservoir Tank 2 Nos With Site Pit And Out Side Back Wash Pit Including Cost Of All Labour T&P , Cost Of All Consumables Such As Grease, Lubricating Oil, Mobil Oil, Gear Oil, Packing Seat, Coupling Of Gear Box , Gland Dori Etc. Required For Proper Completion Of Work. Work Includes The Up Keeping And Cleaning Of Surrounding Area Of Filteration Plant, Daily Collection Of Treated Water S Le From Filteration Plant And Submitting The Same To Chemistry Lab Of 2X210mw For Testing And Collection Of Report And Maintaning The Test Register. Work Also Includes The Watch & Ward Of The Filtration Plant Complax Round The Clock And Daily Cleaning/Dusting Of All Equipments Fixed At Filteration Plant As Pump, Motors, Main Switches, Starters Etc. And Disposal Of Debries Out Side The Periphery Of Filtration Plant. , Operation Of Tube Well Daily By A Suitable Experienced Operator Continuously Or In Different Intervals As Per Program Fixed By Engineer-In-Charge Including Opening And Closing Of Valves, Greasing Of Motor, Changing Of Fuse Wire Etc. As Required For Proper Running Of Tube Well/Pump Set Of 15 Hp Inside Power House Area (Store Area). , Operation Of Over Head Tank 190 Kl And Pump House Near Type-Ii Area (Near Ministrial Club) As Required Including All Valves, Indicator And Cleaning Of Stairs, Structure And Area Inside Boundary Wall And Its Watch And Ward 24 Hrs. Daily. , Operation Of Pump Set Of 15 Hp And Tubewell Near Inter College Area (Type Iii) As Required Three Times Daily , Re-Winding Of Ac Mono Block, 3 Phase Motor, With Best Quality Insulating Material, Including All Charges Of Dismantling Of Motor And Its Pertaining Items Such As Suction And Delivery Pipes If Required And Stacking In Departmental Store And Including All Charges For Re Fixing Of Motor And Also Fixing Of Motor At Any Tube Well/ Pump House As Per Direction Of Engineer- In -Charge, Including Supply And Fixing Of All Material Like Nut, Bolt, Washer Packing Welding Grinding Of Shaft Etc. And Testing Of Motor Etc. All Complete . All Waste Material Like Burnt Wire Shall Be The Property Of The Contractor.3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Same As Item No 5 But Rewinding Of Submersible Motor Of Following Pump.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Repairing Of Following Submersible Pump Including All Charges Of Dismantling Pump And Its Purchasing Item Such As T&P Etc.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Providing & Fixing Of Bearings S.K.F. Or Nbc (From Main Distributor Produced With Orignal Cash Memo) Equivalent Make Including Removing Of Bearing From Pump/Motor Including Cost Of All Labours Material, T&P Etc. All Complete, 3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Supply & Filling Of 16/30 Gauge Approved Ram Nager Betwa Sand In Filter Bed Of Filtration Plant Situated In Colony Area Of Parichha Thermal Project, Parichha. , Taking Out Of Gear Box Fixed A Colony Water Treatment Plant Rotating Bridge, Opening Its Nut & Bolts, Replacement Of Gear Oil Big Oil Seal No. (Kds/1335/P25 Die 175.3), Small Oil Seal No. Kds-2705, Including Packing , Oiling, Tightening Of Nut & Bolts And Assembling , Reerecting , Repairing The Same On Bridge With Flocculate Or Rotating Bridge Including Making Proper Alignment With All Required Arrangements Including The Cost Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Warm Shaft And Gear Of Gearbox Of Suitable Make By Filling Of Required Type Of Material Over Gear And Shaft (Warm Shaft) And Cutting Grove, Thread Etc. Over If On The Lathe Machine As Per Specification. Including The Cost Of All Material, T&P, Carriage Etc. Required For Proper Completion Of Work. , Same As In Item No 17 Above But For Providing And Fixing Of Rotating Shaft , Providing Fixing Of Thrust Bearings S.K.F. Or Nbc Make Of Approved Quality For Reduction Gearbox Of Approved Make And Including Removal Of Old Bearing, Checking Of Bore Size Inner And Outer And Fixing It In Proper Alignment Including Cost Of All Labours Material, T&P Etc. All Complete, For Warm Shaft (Gear Shaft) , For Rotating Shaft. , Opening Out Complete Assembly Of 25 Hp Pump And Column Pipes Fitted Of The Pump House Near 450 Kl Over Head Take, Repairing And Re-Fixing Including Other Cost Of All Material Such As Rubber Bush Bearing, Nut Bolts And Gland Plate Etc. Machinery Work, Grinding, Cutting Threading, Transportations Etc. If Required And General Over Hauling Of Complete Pumps For Proper Completion Of Work. , Same As In No. 21 Above But For 30 Hp Pups Installed At Colony Filtration Plant. , Supply And Fixing Of The Following Starter L&T Or Other Equivalent Approved Make For Following Motors., 5 Hp Ml-1 , (7.5 Hp-10) Ml-2 , (15 Hp-20 Hp) Ml-2 , Above 20 To 25 Hp Ml-2 , Providing And Fixing Of Bush Of Approved Quality For 5 Hp To 15 Hp Pumps Including The Cost Of All Labour Involved For Opening Out & Re Fixing Of Bush In Pumps And T&P Etc. For Proper Completion Of Work. , Cleaning Of Over Head Tank 450 Kl Capacity Of 28 Meter Staging, Removing & Cleaning Of Silt Mud Sludge Etc, And Its Disposal At Ground With In 30 M Lead And Washing Inside The Tank Disinfecting The Bottom Surface And Walls Of The Tank With Water, Containing Bleaching Powder Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Same As Above In Items No.28 But For 100 Kl To 190 Kl Capacity Over Head Tank Of 15 To 20 Meter Staging , Same As Above In Items No.28 But For 50 Kl To 150 Kl Capacity Under Ground Water Tank. , Supply And Fixing Of Gland Plate For Upto 10 Hp Water Pump Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Starter For Electric Motor, Opening Out , Choking , Changing Its Oil, Minor Parts Such As Nut, Bolts, Washer, Damaged Contacts And Other Parts Required Including Of All Material, T&P Etc. Required For Proper Completion Of Work.(Cost Of Relay Sale Be Paid Extra As Per Actual) , Providing And Fixing (150 Mm Dia To 200 Mm Dia) Non Return Value (Nrv) Isi Make Of Approved Quality Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work.(With Minimum 6 Months Guarantee.) , Providing And Fixing Brass/Gunmetal Impeller For 30 Hp Vlt/Turbine Pump Installed At Filtration Plant In Colony Area As Per Details Given Below And As Per S Le. Including Supply Of All Material Like Seal Ring Lock Vollet , Bearing Coupling , Bush Packing, Nut, Bolt And All Other Material, T&P Etc. Required For Proper Completion Of Work. Make Warthanth/ Jonston /Jyoti, Capacity 180 M3 /Hr , Speed 1460 Rpm Head , 30 M) , Providing And Fixing Of Impeller For The Following A.C. Mono Block Pumps Of Kirloskar Or Other Approved Make Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. 5 Hp To 7.50 Hp , 10 Hp To 15 Hp , Providing And Fitting The Following Items Upto 15 Hp Ac Mono Block Pumping Set All Material, T&P Etc. Required For Proper Completion Of Work With Pvc Cooling Fan Of Approved Quality. , P/F Key Way Of Coupling , Re-Metallising Of Bearing Seat On Rotarshaft And Machining , P/F Terminal Plate. , P/F Cooling Fan Cover Of Motor. , P/F Terminal Box Of Motor. , Replacing Of Set Of Main Contact Of Starter (L&T) Make Of Isi Mark Including The Cost Of All Labour, Material And T&P Etc. Required For Proper Completion Of Work. , P/F Of Condenser Of 45 Mfd Isi Mark For 2 H.P. Single Phase 230 V.A.C. Starter. , Repairing Of Following Sluice Valve Including Opening Out And Refixing Of Sluice Valve Accessories Such As Nut, Bolt, Glane, Repaired Spendil Etc. Including The Cost Of Machinery Arrangement, Nut, Bolt, Packing Etc. All Complete.(Min. Three Months Guaranty) Filling Required Type Of Metal Over Spindle And Gutka For Spindle And Machining Cutting Threading Over Spindle Its Clearing Of Rod On Lath Machine And Gutka Fixing In Spendil Etc. Or Replacement With New One (Old Material Will Be Property Of Contractor) And Re-Fixing Of All Accessories Including All Cost And Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm Dia , 150 Mm Dia , 200 Mm Dia , 250 Mm Dia , 300 Mm Dia To 400 Mm Dia , Filling Required Type Of Metal Over Sluice Valve Seat Both Sides Including Cutting , Grinding, Welding , Fixing , Of Nut , Bolt, Washer In Sluevalve If Required Including Of Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm To 125 Mm Dia , 150 Mm Dia To 250 Mm Dia , 300 Mm To 400 Mm Dia , Providing Cotton Mosquito Proof Net Covers To Water Beds Of Filter Plant Of Size Approximate 6.20X4.0X0.90 M Doubly Stitched From Inside And Outside With Minimum 25 Mm Wide Cotton Strip Including Cost Of Material Labour, Cartage, Taxes T&P Etc. Complete. , Hiring Charges Of Breaker Including Cost Of Tractor,Operator Deisel ,Lead Upto 50 Meter And All T&P Required For Execution Of Work. , Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 25 To 40 Mm Nominal Bore , 50 To 80 Mm Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc External Work, 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , 125 Mm Dia , 150 Mm Dia , Same As Above In Item No. 5 But Without Excavation, 15 Mm Dia , 20 Mm Dia , Providing & Fixing Of G.I. Reducing Socket For ‘B Class Pipe Of Following Dia Including Supply Of All Material, Labour T&P Etc. Complete. 20 X 15 Mm Dia , 25 X 20 Mm Dia , 50 Mm To Any Smaller Size , 65 Mm To Any Smaller Size , 80 Mm To Any Smaller Size , 100 Mm To Any Smaller Size , Dismantling G.I. Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer-In-Charge, 15 Mm To 40 Mm Nominal Bore , Above 40 Mm Nominal Bore , Supply And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Supply And Fixing G.I. Bend/Elbow Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;75 Mm Diameter , Same As Above But 110 Mproviding And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;110 Mm Diameterm Outer Dia , Providing And Fixing 110X25 Mm Outer Dia Pvc Saddle Or 110 Mm Outer Dia Pvc Including Rubber Ring Including All Excavation, Refilling The Trenches Including Cost Of All Material Labour T&P Etc. , Providing And Fixing Pvc Flange Tail Piece For 110/90 Mm Outer Dia Pvc Pipe Line , Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertions Etc. (The Tail Pieces If Required Will Be Paid Separately) :100 Mm Diameter Class I , 150 Mm Diameter Class I , Providing And Fixing G.I. Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required : 15 Mm Nominal Bore. , 20 Mm Nominal Bore. , 25 Mm Nominal Bore. , 50 Mm Nominal Bore. , Repair Of Leakage In G.I./C.I./M.S./Pvc Pipe Line Of 20 Mm Dia To 200 Mm Dia Including Necessary Excavation Dismentalling And Relaying Of Pipe And Refilling Of Trenches Also Including Supply And Replacement Of Nuts/Bolts Washes Socket Flange Tail Piece, Spun Yard Safeda Welding Etc. Complete. 20 Mm Dia To 40 Mm Dia Pipe Line , 50 To 125 Mm Dia , 150 To 200 Mm Dia , Repair Of Reflex Valve By Removing It From Pipe Line Or Section And Of Pumping Set From Any Tube Well Opening Its Nuts And Bolts Replacing The Rubber/Leather Washer Making It Water Tight By Lightening Of Nuts And Bolts Reerecting/Refixing The Same In Pipe Line On In Tube Well Suction And Including Cost Of Job For Diameter Ranging From 100 Mm To 200 Mm Dia Including Taking Out Suction Pipe Of Required. , Supplying And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete.40X40x15/20 Mm Dia , 50X50x15/20 Mm Dia , Providing And Fixing 100 Mm Dia C.I. N.R.V. I.S.I. Marked Approved Quality Including Cost Of Al Labour, T&P Etc. Required For Proper Completion Of Work , Supply Of D Joint Of Following Dia Including Cost, Cartage Etc. Complete. 65Mm To 80 Mm Dia , 100 Mm Dia , 150 Mm Dia , Dismantling Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50Metres Lead As Per Direction Of Engineer-In-Charge : Water Bound Macadam Road , Bituminous Road , Cleaning Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : 25 Mm Nominal Bore , 50 Mm Nominal Bore , 65 Mm Nominal Bore , 80 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete,15 Mm Nominal Bore , 20 Mm Nominal Bore , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5M, Disposed Earth To Be Levelled And Neatly Dressed. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Fixing Brass Stop Cock Of Approved Quality Weight Not Less Than 400 Gram. 15 Mm Nominal Bore. , Attending To Petty Maintenance Services Like Plumbing, Welding, Carpenting, Mason With One Carpenter Plumber Or Mason And One Helper Per Hour , Dewatering By Pump Of Capacity 5/7.5 Hp With 4 Meter Sump And 50 Meter Pump Length Including Installation, Operator/Helper, Desiel/Fuel Etc As Per Direction Of Engineer In Charge.
Contract Date: Ref. Documents Contract Value : 36.48 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
14.
Water Resources and Irrigation #11223260 Price Bid
Tender for Repair Of Control Panel And Providing/Fitting Of Foot Valve Of Priming Pump Along With Allied Works At Lis Khawas Khan. , Repair And Reconditioning Of Existing 125 annual periodical maintenance Lt Control Panel Of 415 Volts, Ac 3 Phase, 50 Hz At Lift Irrigation Station Khawas Khan Serving 2 Nos. Motors Of 20 Hp Each By Way Of Replacement Of Faulty/Non-Functional Multispan Mpd 192 (Or Equivalent Isi Standard Make) Motor Protection Device/Fault Analyzer After Extracting The Old Damaged One By Way Of Disconnecting All The Existing Wiring Connections At Its Terminals And Removing It From The Panel Enclosure. providing and Fixing Of New Multispan Mpd 192 Or Equivalent Protection Relay In Its Place And Reconnecting All The Control Wiring As Per The Original Wiring Scheme. Setting/Configuration Of The New Protection Device For 20 Hp Motor Parameters Including Overload Threshold, Underload/Dry Run Detection Level, Over/Under Voltage Limits, Phase Unbalance And Earth Leakage Settings As Per Motor Nameplate Data. Replacement Of 3 Nos. Existing L&T Mnx 25 (25 Amp) Air Break Contactors Of The Star Delta Starter Of Motor No. 1 Which Are Undersized For 20 Hp Motor Rating With 3 Nos. New L&T Mnx 40 (40 Amp) Or Equivalent Isi Standard Make Air Break Contactors Comprising Of 2 Nos. 40 annual periodical maintenance Contactors For Main And Delta Duty And 01 No. 40 Contactor For Star Duty After Extracting The Old Undersized Contactors By Way Of Disconnecting The Power Cables And Control Wiring And Removing The Old Contactors From Their Mounting Arrangement. Reconnecting All Power Cables Of Adequate Current Carrying Capacity And Control Wiring To Appropriate Terminals Of The New Contactors As Per The Star Delta Circuit Including Interlocking Connections Between Star And Delta Contactors To Complete The Star Delta Starting Circuit Of Motor No. 01. Replacement Of Any Faulty Led Indicator With A New Led Indicator Of Equivalent Rating, Colour Coding And Size After Extracting The Old One By Way Of Disconnecting The Existing Wiring Connections And Making Proper Connections To The New Indicator. providing and Fixing Of 1 No. New Reset/Selector Switch In Place Of The Existing Faulty Small Black Reset Switch After Extracting The Old Damaged Switch By Way Of Disconnecting The Existing Wiring Connections, Removing The Old Switch Fitting The New Switch Of Equivalent Type Its Place. Reconnecting The Control Wiring To The New Switch To Restore The Manual Reset Function Of The Motor Protection Relay After A Protection Trip Event. Complete Inspection Of All Internal Control Wiring Of The Panel By Way Of Checking The Insulation Condition Of Flexible Copper Cables, Tightness Of All Crimp/Ferrule Terminations At Terminal Blocks, Contactor Coil Terminals, Push Button Terminals, Indicator Lamp Terminals And Protection Relay Terminals. Replacement Of Any Damaged Or Deteriorated Wiring As Per Actual Site Requirement. Verification Of Correct Phase Sequence Of Incoming Supply Using Phase Sequence Meter Before Energization Of The Panel. Testing And Commissioning Of The Repaired/Upgraded Panel On Full Load By Way Of Energizing The Panel After Completion Of All Repair Works, Verifying Healthiness Of All Three Phase Indicator Lamps At Incoming Section, Checking Voltmeter And Ammeter Readings On All Phases Using Selector Switches, Testing Start/Stop Operation Of Both Motors, Verifying Correct Star To Delta Changeover Of Motor No. 1 Starter, Verifying Display And Protection Functions Of The Motor Protection Devices On All Phases And Recording The Full Load Running Current Of Both Motors. Underground Laying Of Aluminum Cable From From Pump Room To The 100 Kva Distribution Transformer Approximately 20 Feet Apart, By Way Of Excavation Of A Trench Of 9 To 12 Inches Depth And 20 Feet In Length Using Manual Labour With Tools And Tackles. Inspection Of Cable And Insulation Of All Joints And Any Other Locations Found Requiring Insulation During Inspection By Way Of Proper Wrapping With Good Quality Pvc Insulation Tape In Multiple Overlapping Layers So As To Ensure A Moisture Proof And Mechanically Sound Insulation At All Such Points Along The Cable Run. Laying Of The Cable In The Excavated Trench In A Neat And Orderly Manner With Adequate Slack Provided At Both Ends To Facilitate Making Of Electrical Connections. The Cable To Be Laid Without Kinks, Twists Or Sharp Bends So As To Avoid Mechanical Damage To The Cable Insulation. Filling Of The Trench With Excavated Earth With Proper Compaction Using Manual Labour Along With Requisite Tools And Tackles. Removal Of The Old/Damaged Foot Valve Of Priming Pump Of 2 Hp From The Suction Pipe By Way Of Cutting The Rust Nuts And Bolts. providing and Fixing Of 01 No. New 2.5 Inch Foot Valve Of Standard Make With Appropriate Size Of Flange, New Nuts And Bolts Of Appropriate Size Along With Rubber Gaskets/Packing Of Suitable Thickness So As To Ensure A Leak Proof Joint. The Job Also Involves Cutting Of Rusted/Damaged Flange From The Suction Pipe Piece End And Providing And Welding Of New Flange Of Requisite Size To The End Of Suction Pipe Piece. Lowering Of The Suction Pipe Assembly Along With The Newly Fitted Foot Valve Back Into The Canal To Its Original Position Using And Manual Labour. Securing Of The Pipe In Its Correct Position As Per Original Installation. Testing And Commissioning Of The Priming Pump With The New Foot Valve By Way Of Priming The Pump And Running It On Full Load To Verify Proper Suction, Absence Of Air Leakage At The Foot Valve And Correct Pumping Action. Rewinding Of 2 Hp, 3-Phase, 415V, 50 Hz Priming Pump Motor At Lis Khawas Khan By Way Of Dismantling Of Motor Assembly From Pump Set Using Tools And Tackles And Carriage To Workshop. Stripping Of Old Burnt/Damaged Stator Winding From Stator Slots And Cleaning Of Stator Core And Slots. Rewinding Of Stator With New Standard Copper Winding Wire Of Appropriate Gauge In Same Winding Configuration As Original With New Slot Insulation Liner Paper Of Appropriate Class. providing and Fixing Of New Connecting Leads And Terminal Connections Of Appropriate Size. Impregnation Of Completed Winding With Class B/F Insulating Varnish By Way Of Dipping And Oven Baking. Reassembly Of Motor And Replacement Of Bearings If Found Defective. Fabrication And providing and Fixing Of New Terminal Plate In Place Of Existing Worn Out/Damaged Terminal Plate Of Priming Pump Motor By Way Of Removal Of Old Terminal Plate And Fabrication Of New Terminal Plate From Bakelite Sheet Of Appropriate Size And Thickness. providing and Fixing Of New Isi Standard Brass Terminal Studs, Nuts And Washers Of Appropriate Size And Current Rating. Proper Insulation Of Terminal Connections By Way Of Pvc Sleeving And Ferrules Of Appropriate Size. Reconnecting Motor Winding Leads To New Terminals And Testing For Proper Insulation Resistance And Contact Continuity Using Megger. Back Shifting Of Rewound Motor To Site, Fitment And Testing On Full Load. Complete Job Includes Cost Of All Materials, Consumables Including Rebate On Old/Damaged Components, Carriage Of Material To Site, Labour Charges Of Skilled As Well As Semi-Skilled Labour, Testing And Commissioning Charges At Lis Khawas Khan. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
15.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
16.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
17.
Coal and Mines #11189769 AOC
Bids Are invited for Spares Of Meditron Make Ht Switchgears And Vaccum Circuit Breakers Vaccum Bottle - Vaccum Bottle Part No Me4531 , Spring Charging Motor - Spring Charging Motor Part No Me4540 , Potential Transformer Epoxy Resin Cast - Potential Transformer Epoxy Resin Cast Part No Med2120 , H D Resin Cast Ct Part No Md2231 , Trip Coil - Trip Coil Part No Me4537 , Closing Coil - Closing Coil Part No Me4538 , Single Phase Rectifioer Or Power Pack - Single Phase Rectifioer Or Power Pack Part No Mer5340 , Complete Manually Operated Mechanism - Complete Manually Operated Mechanism Part No Mev4222 , Complete Vaccum Circuit Breaker Truck - Complete Vaccum Circuit Breaker Truck Part No Medv6191 , Resin Cast Bottle Housing - Resin Cast Bottle Housing Part No Mv3305 , Limit Switch - Limit Switch Part No Me4539 , Indicating L - Indicating L Part No Me4543 , Hv Fuse Link - Hv Fuse Link Part No Med332443 , H D Resin Cast Ct Part No Md2214 , H D Resin Cast Ct Part No Md2217 , Earth Leakage Relay - Earth Leakage Relay Part No Mer5310 , 4P Non Directional Idmt Static Relat - 4P Non Directional Idmt Static Relat Part No Mer5510 , Master Trip Relay - Master Trip Relay Part No Mer5530 , Multifunctional Ai Energy Meter - Multifunctional Ai Energy Meter Part No Mer335560 , Digital Energy Meter 3Ph 3 Wire - Digital Energy Meter 3Ph 3 Wire Part No Mer5570 , Auxillary Contactor - Auxillary Contactor Part No Mer5605 , Ammeter - Ammeter Part No Mes4701 , Voltmeter - Voltmeter Part No Mes4702 , Voltmeter Selector Switch - Voltmeter Selector Switch Part No Mes4704 , Hrc Fuse Link - Hrc Fuse Link Part No Mes4710 , Digital Earth Leakage Relay Door Mntd 110V - Digital Earth Leakage Relay Door Mntd 110V Part No Mes4715 , Breaking Charging Handle - Breaking Charging Handle Part No Mv3302 Total Quantity : 278
Contract Date: Ref. Documents Contract Value : 42.60 Lakh
Boards / Undertakings / PSU No of Bidders 1
18.
Public Administrative Department #11187273 AOC
Tender For Safety Related Works At Maa Hospital, Postal Colony, Chembur E Mumbai. - Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 2820 LPM (Litres/min.) at 88m centrifugal type pump 2 SITC of Jockey Pump of 240 LPM at 88m head 3 SITC of Booster Pump of 450 LPM at 88 m head 4 415V Main Distribution Panel 1 short circuit reating 50kA for 1 Sec. 630A (Thermal magnetic overload, short circuit release & earth leakage module) MCCB with rotary operating mechanism as incomer with digital ammeter, voltmeter with selector switches, phase indicating lamp with required accessories, 1Nos. 63A, 3Noss. Of 100A, 2Noss. 160A & 200A (total 8Noss.) MCCB of short circuit rating 25kA for 1 sec. as outgoings. 5 Providing and fixing in position G.I. Heavy grade C class pipes 200 mm 6 Providing and fixing in position G.I. Heavy grade C class pipes150 mm 7 Providing and fixing in position G.I. Heavy grade C class pipes100 mm 8 Providing and fixing in position G.I. Heavy grade C class pipes 80 mm 9 Providing and fixing in position G.I. Heavy grade C class pipes 65 mm 10 Providing and fixing in position G.I. Heavy grade C class pipes 50 mm 11 Providing and fixing in position G.I. Heavy grade C class pipes 40 mm 12 Providing and fixing in position G.I. Heavy grade C class pipes 32 mm 13 Providing and fixing in position G.I. Heavy grade C class pipes 25 mm 14 Painting of 7 mtr G.I./M.S. Pole (All types). 15 Supplying & Installing cast iron double flange butterfly valve 200 mm 16 WAFER TYPE BUTTERFLY VALVES: -150 mm dia. 17 WAFER TYPE BUTTERFLY VALVES: -100 mm dia. 18 WAFER TYPE BUTTERFLY VALVES: -80 mm dia. 19 Supplying and installing double flange NRV 150 mm 20 Supplying and installing double flange NRV 80 mm 21 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0- 14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc 22 Supplying and installing pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification 23 1st category Cu armoured cables FRLSZ outer sheathed- 3.5C x 35 Sq.mm 24 Cable End Termination For Aluminium Cables – 3C x 35 Sq.mm 25 Earthing Continuity Conductors -50 x 6mm GI 26 2nd category Cu armoured cables FRLSZ outer sheathed- 2C x 1.5 Sq.mm 27 50 x 50 x 6 mm of M.S.angle. 28 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 29 Supplying & installing moulded HDP / Fibre water tank. for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification 30 Supplying and erecting 20/25mm Ø G.M.air release cock, with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification 31 Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S. tank installed inside pump house as per specification 32 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -150 mm dia. 33 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -100 mm dia 34 Supplying and installing gun metal Double outlet hydrant valve fitted with necessary accessories 35 Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories 36 Supplying Stainless Steel branch Pipe 63 mmØ fitted with 20 mm dia detachable hexagonalnozzle as per specifications 37 Providing and fixing in position 2 lengths of 15 M long flexible canvas rubber lined hose reels 63 dia with adapter, branch pipe and nozzle and storing them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted including painting etc 38 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour 39 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 40 Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 100 mm Ring Main of Fire Fighting System. 41 Excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 Cu. Mtr. = 2.2 RMT. 42 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification 43 Cement concrete foundation using M-20 cement concrete mix with J shaped foundation bolts where required 44 Supply & Laying of double wall corrugated ( DWC) pipe 120 mm OD / 103.5 mm I.D. 45 Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. 46 Providing, detailing, composite fabricating members like Trusses, N-girders, girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using M.S. hollow tubular steel sections (circular & rectangular pipes), of TATA Structura Make or equivalent conforming to IS 1239 part 1 and 2 and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transportion of the same to site, erection of structural steel members for all heights & at all levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding, removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. 47 Bare Galvalume/zincalume sheets for roofing 48 Rubber mat 2mm thick size 3x5 feet 49 Earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe (Class B or better) earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25x3 GI strip/ / 2X8SWG G.I. wire up to chamber (wire or strip size as per fault level), disconnecting links with 600 x 600 mm (clear) RCC chamber & heavy duty 3mm thick CI chequered plate cover with hinge & stainless steel bolts. Bentonite/ Charcol & Salt shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope 50 Earthing Continuity Conductors -25 x 6mm Tinned copper 51 Earthing Continuity Conductors – Bare Copper Conductor size 12 SWG 52 45 Degree Leg Press (free Wts.) 53 Supply, Installation, testing & commissioning of addressable 2 loop main fire alarm electronic control panel, expendable up to 4 loop & having maximum 250 devices (any combination detectors plus devices) per loop & Audio/ Visual alarm complete as per IS: 2189 specification - modular type front operated with interlocking door arrangement totally enclosed dust and vermin proof for indoor type applications. 54 Supply, Installation, testing & commissioning of Active Repeater panel with all accessories, which shall be replica of main fire alarm panel with control keys I,e. Mute, silent & sounder alarm. 55 Supply, Installation, testing & commissioning of expandable Loop card for main fire alarm electronic control panel, shall support 254 devices both detectors and modules and shall support both class A & class B wiring. 56 Supply, Installation, testing & commissioning of Intelligent multi- criteria Detector along with mounting box & termination glands. 57 Supply, Installation, testing & commissioning of Intelligent Photoelectric Smoke Detector along with mounting box & termination glands. 58 Supply, Installation, testing & commissioning of Addressable Manual call point/ station with mounting back box 59 Supply, Installation, testing & commissioning of Addressable control Relay module with required accessories along with junction box, glands and terminators ( For AC trip off, Access trip off, PA system, sprinkler flow switch, lift interface, sounder, fire fighter & telephone jack) 60 Supply, Installation, testing & commissioning of Isolator Module along with mounting box & termination glands. 61 Supply, Installation, testing & commissioning of remote response indicator 62 Supply, Installation, testing & commissioning of Strobe Lights along with mounting box & termination glands. 63 Cable End Termination For Copper Cables – 2C x 1.5 / 2.5 Sq.mm 64 Supply, Installation, testing & commissioning of 2Cx1.5 sq.mm armoured RED color copper FRLS cable with necessary saddles, screws, junction boxes, sleeves, elbows couplings etc. for Fire alarm System 65 Supply and installation of Mixer amplifier 120W (4 channel input & 1 line level balanced output) 66 Supply and installation of Booster amplifier 300W with all accessories. 67 6W/100V. PA Ceiling Speaker 68 Delegate unit Microphone 69 Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver Paint. 70 SITC of Auto glow signage for Emergency Fire Exit 71 SITC of Auto glow signage for Do not use lift in case of Fire etc. 72 Clean Agent Fire Extinguisher 73 Fire B-Form Charges 74 Mock drill test (1st Year and 3rd Year) 75 CSMC 5% for 1st year 76 CSMC 5% for 2nd year 77 CSMC 5% for 3rdyear
Contract Date: May 29, 2026 Contract Value : 1.35 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
20.
Power #11176094 Price Bid
Tender for Supply Of Electrical Items And Stores Hardware Items For Sub-Transmission Division-Ii, Jpdcl, Jammmu For The Year 2026-27 , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Termination Connector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks. A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocb Bicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocb Crompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , J) Male Contact For Ocb Mei Make (With Silver Coating) , K) Female Contact For 11 Kv Ocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kv Ocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) annual rate contract Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45....65 Hz, With Rs485 Output, Aux Voltage: 1260V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5-5 , Iii) 600/300/5-5-5 , Iv) 600/300/5-5-5 , V) 400/200/5-5 , Vi) 300/150/5-5 , Vii) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One) With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 annual periodical maintenance , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based (Abc Type) 4 Kg. , C) Power Based (Abc Type) 6 Kg. , D) Power Based (Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories , 30V, 25A Battery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( detail project report 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make, Model: 30V Dc Dcps, Smps Based Dc Power System. , Main Control Card Suitbale For Use In - Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dc Boost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 Mω (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banks Apfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/√3/110V/√3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain) , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 11Kv Pt Indoor Type Resin Cast 11 Kv/110V (3 Nos) , 11Kv Pt Draw Out Type Along With Housing 11 Kv/110V (1 Complete Set) , 11 Kv Vaccum Interrupter Type Vge4 Abb Make For Pascal Vcb , 11 Kv Vaccum Interrupter Stelmac Make , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Electricfield , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Pascal , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Stelmac , Spring Charge Motor For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Stelmac , Micom Alstrom P14n Relay With 61850 Scada Compatibale Port , Ashida Make Relay Adr 241B With 61850 Scada Compatible Port , Ashida Make Relay Adr 241A Non Scada , Ashida Realy Adr 141C , Master Trip Relay Alstrom Make , Led Indicator 36 V Dc , Ethylene Propylene Rubber (Epr) Self Amalgamating Tape 38Mmx9mtr Scapa/3M , Ampere Selector Switch , 66 Kv Disc Insulator B&S Type Polymer , 66 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , Battery Charger Automatic Float-Cum-Boost Charger Input 190-230 V Ac 1Ph, Output 30 V Dc 25 annual periodical maintenance With Full Wave Rectification, Output Float Voltage: 33.0 Vdc Output Boost Voltage: 35.0 Vdc With Test Report. , Frp Extendable Ladder Of 10M , Polywater® Powerpatch® Transformer Seal And Pilc Cable Repair Allow For The Repair Of Active Leaks In The Field , Wrist Type High Voltage Detector , Hydraulic Crimping Tool Upto 630 Sq Mm Size , Digital Earth Clamp Tester , 60 Kv Motorised Oil Bdv Kit , Switch Disconneter Fuse 160 A , Mcbs 63A , 9 Mtr. St Poles , 11 Mtr. St Poles , 13 Mtr. Poles , Gaskets Of Of All Sorts For Power Transformer , 33 Kv Frp Crossarm , Frp Channels Of (100X50x6) Mm , Frp Angles Of (65X6)Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
21.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
23.
Chemicals and Fertilizers #11136161 AOC
Bids Are Invited For Spares For 220V Battery Charger Total Quantity : 107; 1 M7304080100 ELECTRO CAP, SCREW, 2200MFD/400VDC PG6D ELECTRO CAP, SCREW, 63mm 2200MFD/400VDC PG6DI -ALCON, Part No -EA76033130000AL0, for chhabi make battery charger (Model no- CE3962/2011/161) NO 6 2 M7304080101 ACONT MINI TCA3-M22 MD,10A-NO+NC 220V DC ACONT MINI TCA3-M22 MD,10A-2NO+2NC 220V DC, C&S, Part No -BM110A0PG40000CS, for chhabi make battery charger (Model no- CE3962/2011/161) NO 2 3 M7304080102 ACONT MINI TCA3-M22 BD, 10A-NO+NC 24V DC ACONT MINI TCA3-M22 BD, 10A-2NO+2NC 24V DC, C&S, Part No -BM110A0PG80000CS, for chhabi make battery charger (Model no- CE3962/2011/161) NO 2 4 M7304080103 PCONT TC1-D1810 U5, 18A3PAC 1NO 240V AC PCONT T RANGE TC1-D1810 U5, 18A3PAC 1NO 240V AC, C&S, Part No - AC318A0CB60000CS, for chhabi make battery charger (Model no- CE3962/2011/161) NO 2 5 M7304080104 CONV DC/DC IP90-270VAC OR 90-350VDC CONV DC/DC IP90-270VAC OR 90-350VDC, O/P 24V 2.5A AS464-104 (OPEN TYPE) SH, Part No -CON18035024V25SV, for chhabi make battery charger (Model no- CE3962/2011/161) NO 2 6 M7304080105 CAPACITOR POLY, 0.22 MFD/ 630VCT CAPACITOR POLY, 0.22 MFD/ 630VCT, Part No - CAP5120845CT0000, for chhabi make battry charger (Model no- CE3962/2011/161) NO 10 7 M7304080106 WIRE WOUND SI-COTED 33E-RADIAL 10W, OT WIRE WOUND SI-COTED 33E-RADIAL 10W, OT, Part No -WW033E000R0100OT, for chhabi make battry charger (Model no- CE3962/2011/161) NO 10 8 M7304080107 3 PH FWFC SCR CONT MODULE PCB NO 52/R1 3 PH FWFC SCR CONT MODULE PCB NO 52/R1 CE, Part No -CON02052R1000CE0, for chhabi make battry charger (Model no- CE3962/2011/161) NO 1 9 M7304080108 AUTOMATIC CHANGEOVER RELAY MODULE PCB NO 1 AUTOMATIC CHANGEOVER RELAY MODULE PCB NO 80R1 CE, Part No -ACOR1A010080R1CE, for chhabi make battry charger (Model no- CE3962/2011/161) 10 M7304080109 24V TO 12V / 1.5A DCDC CONVERTER MODULE 24V to 12V / 1.5A DCDC Converter Module PCB No 303 CE, Part No -DCDC2412P303M0CE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 11 M7304080110 DC OVER LOAD RELAY 24V DC MODULE PCB DC OVER LOAD RELAY 24V DC MODULE PCB NO. 046R4 75mV CE, Part No - DCOLA0146R424VCE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 12 M7304080111 DC U & O VOLTAGE RELAY CARD MODULE PCB DC U & O VOLTAGE RELAY CARD AS MODULE PCB NO 44RA7 CE, Part No -DCUOVA01044R7ACE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 13 M7304080112 EARTH LEAKAGE RELAY CARD AS MODULE PCB EARTH LEAKAGE RELAY CARD AS MODULE PCB NO 34R4 CE, Part No -EALE1A01034R4ACE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 14 M7304080113 FFD 3 FS W RELAY CARD AS MODULE PCB FFD 3 FS W RELAY CARD AS MODULE PCB NO 47AR4 CE, Part No -FF3F2A0147AR4ACE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 15 M7304080114 FFD 6FS W RELAY CARD AS MODULE 2IN1 PCB FFD 6FS W RELAY CARD AS MODULE 2IN1 PCB NO 47AR4-2 CE, Part No -FF6FW302047AR4CE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 16 M7304080115 HV PF PSR PST MODULE PCB NO 53R1 415V HV PF PSR PST MODULE PCB NO 53R1 415V CE, Part No -HVPFPA01053R1OCE, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 17 M7304080116 MODULE 52RA4 SUPPORTING TO MODULE 52R1 MODULE 52RA4 SUPPORTING TO MODULE 52R1 (POT MODULE), Part No - MOD52RA4SPMD52R1, for chhabi make battry charger (Model no- CE3962/2011/161) NO 2 18 M7304080117 MILIVOLT AMPLIFIER R1 MODULE PCB MILIVOLT AMPLIFIER R1 MODULE PCB NO 0106 75mV CE, Part No -MVAM1A010106ABCE, for chhabi make NO 2 battry charger (Model no- CE3962/2011/161) 19 M7304080118 500MAFUSE LINK,230V, SMALL, GLASS, OT 500mAFUSE LINK,230V, SMALL, GLASS, OT, Part No - OA4031SMLGOTOOOO, for chhabi make battry charger (Model no - CE3962/2011/161) NO 20 20 M7304080119 SEMICOND FUSE LINK 35A 690VAC Type 35ET SEMICOND FUSE LINK 35A 690VAC Type 35ET, Part No -SFSL35ETGSB000BS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 6 21 M7304080120 CL LED IN RED RCB7 IVL74 240VAC 22.5 CL LED IN RED RCB7 IVL74 240VAC 22.5, Part No - CLIRERCI74240VCS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 22 M7304080121 CL LED IN YEL RCB7 IVL78 240VAC 22.5 CL LED IN YEL RCB7 IVL78 240VAC 22.5, Part No - CLIYERCI78240VCS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 23 M7304080122 CL LED IN BLU RCB7 IVL76 240VAC 22.5 CL LED IN BLU RCB7 IVL76 240VAC 22.5, Part No - CLIBLRCI76240VCS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 24 M7304080123 CL LED IN GRE RCB7 IVL73 24VDC 22.5 CL LED IN GRE RCB7 IVL73 24VDC 22.5, Part No - CLIGRERCI7324VCS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 25 M7304080124 CL LED IN RED RCB7 IVL74 24VDC 22.5 CL LED IN RED RCB7 IVL74 24VDC 22.5, Part No - CLIRERCI74024VCS, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 26 M7304080125 DD MODULE SKKD46 46A 1600PIV DD MODULE SKKD46 46A 1600PIV, Part No - DDMD1600A046SK00, for chhabi make battry charger (Model no- CE3962/2011/161) NO 1 27 M7304080126 TT MODULE SKKT27 25A 1600PIV TT MODULE SKKT27 25A 1600PIV, Part No - TTMD25202510SK00, for chhabi make battry charger (Model no- CE3962/2011/161) NO 1 28 M7304080127 WIRE WOUND SI-COTED 1K-RADIAL 50W, OT NO 5 WIRE WOUND SI-COTED 1K-RADIAL 50W, OT, Part No - WW001K000R0500OT, for chhabi make battry charger (Model no - CE3962/2011/161) 29 M7304080128 WIRE WOUND SI-COTED 4K-RADIAL 25W, OT WIRE WOUND SI-COTED 4K-RADIAL 25W,OT, Part No - WW004K000R0250OT, for chhabi make battry charger (Model no - CE3962/2011/161) NO 5 30 M7304080129 WIRE WOUND SI-COTED 4K-RADIAL 50W, OT WIRE WOUND SI-COTED 4K-RADIAL 50W, OT, Part No - WW004K000R0500OT, for chhabi make battry charger (Model no - CE3962/2011/161) NO 5 31 M7304080130 CAM12A 1P2W NO-OF 380VAC KNOB HNDL PNL CAM12A 1P2W NO-OF 380VAC KNOB HNDL PNLMTG 1T16B -KC, Part No - SWC00012A1AC10KC, for chhabi make battry charger (Model no- CE3962/2011/161) NO 1 32 M7304080131 CAM12A 2P2W NO-OF 380VAC KNOB HNDL PNL CAM12A 2P2W NO-OF 380VAC KNOB HNDL PNLMTG 2T26B -KC, Part No - SWC00012B1AC10KC, for chhabi make battry charger (Model no- CE3962/2011/161) NO 1 33 M7304080132 TIMER ETX, 1CO, 240VAC/24VDC, ON-OFF DLY TIMER ETX, 1CO, 240VAC/24VDC, 30HMS, ON-OFF DLY, 12ODT4 SERIES 175, Part No - TME106C030F01LT0, for chhabi make battry charger (Model no - CE3962/2011/161) NO 1 34 M7304080133 AUX XMER 1-PH AC 270V/2X18-0-18V 20VA NO 2
Contract Date: Ref. Documents Contract Value : 3.90 Lakh
Government Departments No of Bidders 1
24.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
25.
Housing Urban and Rular Development #11066672 Price Bid
Tender For Annual Repair, Maintenance Operation Armo Works Of Civil Electrical Including The Repair And Camc Of Em Equipments At Esis Hospital, Branch Office, Dispensary And Residential Quarters At Margao, Goa, - Epoxy, Grouting Mortar/Admixtures Waterproofing Chemicals Aluminum Sections Float Glass/Mirror Aluminum Composite panels Tile Joint Filler Silicone Sealants Paints Texture Paints Something Polish Melamine Stainless Steel Railings Vitrified Tile Ceramic Tile Cement Gypsum Ceiling Mineral Fibre Tiles Door Accessories C CLASS PIPES (MS/GI) PIPE FITTINGS WELDING RODS RUBBER GASKETS ENAMEL PAINTS PAINT PRIMER ELECTRICAL MCBS/ MCB ISOLATORS/RCCBS/ ELCBS/ RCBOS/ MCB DISTRIBUTION BOARDS/ PRE-WIRED DBS- SINGLE/ THREE-PHASE (VERTICAL & HORIZONTAL- SINGLE/DOUBLE DOOR POLY CARBONATE MCBDB MCCBS CHANGE OVER SWITCH (OFF LOAD/ON LOAD) METAL CLAD SHEET STEEL ENCLOUSER SOCKET/PLUG BOX SFU/PSU HRC/HBC FUSES & BASES AUTOMATIC SWITCHES( BASED) TRANSFER SOLONOID LOAD BREAK SWITCHES FR/FRLS/ FIRE SURVIVAL PVC INSULATED COPPER WIRES/ CABLES (SECURED OR OTHERWISE) MODULAR PLATE SWITCHES AND SOCKETS ELECTRONIC ENERGY METERS SINGLE/ THREE PHASE & TRIVECTOR LUMINARIES PVC CONDUIT (ISI MARKED) STEEL CONDUCT (ERW) (ISI MARKED) FLEXIBLE CONDUIT BAKELITE SHEET TELECOMMUNICATION CABLE TV COAXIAL CABLE CONTROL & INSTRUMENTATION CABLE COMPUTER/DATA CABLE VOLTAGE TRANSFORMERS CURRENT TRANSFORMER MEASURING INSTRUMENTS CEILING FAN EXHAUST FAN/AXIAL FLOW FAN/VENTILATION FAN TAG BLOCK VCB/ HT SWITCHGEAR (11/33KV) ACB (3/4POLE) MV/LV SWITVHGEAR HT/LT CABLE (PVC/ XPLE/ FIRE SURVIVAL) AUTOMATION POWER FACTOR CONTROL RELAY CAPACITORS CABLE GLANDS (DOUBLE COMPRESSION EARTHING LINKS) WITH BI-METALLIC CABLES LUGS/ PVC GLANDS CABLE JOINTING KITS CABLE TRAYS (FACTORY FABRICATED)/RACEWAYS BATTERY (SEALED MAINTENANCE FREE) BATTERY CHARGER DG SET EARTH LEAKAGE RELAY SINGLE PAHSING DEVICE PUSH BUTTONS TIME RELAY DEVICE SELECTOR SWITCHES ROTARY SWITCHES INDICATING LIGHTS TERMINALS STREET LIGHT FIXTURES (HALOGEN/ PL/ METAL. HALIDE/MV/5V) MS SWAGED TUBLAR POLE STREET LIGHT POLES TELEPHONE OUTLETS MOTORS EPBAX SYSTEM & TELEPHONE LIGHTING UNIT UIS PROTECTION STARTERS (SOFT/ DOL/ AUTOMATIC STAR DELTA/ SUBMERSIBLE PUMPS BUTTERFLY VALVES DUAL VALUES PLATE CHECK BALANCING VALVES GLOBE VALVES TEMP/PRESSURE GAUGE WITH ISOLATING VALVE CONTROL INSTRUMENTATION CABLE ACB (3/4 POLE) MCCB MCB MEASURING INSTRUMENTS HRC FUSE & FITTINGS CURRENT TRANSFORMERS CONTACTORS STARTER OVERLOAD RELAYS INDICATING LIGHTS SELECTOR/ TOGGLE/ROTTARY SWITCHES CHANGE OVER SWITCH TIME DELAY DEVICE SINGLE PHASE DEVICE FUSE SWITCHES/SWITCH FUSES/ SWITCHES ISOLATING ELECTRICAL PANEL/ SUB- PANEL AHU PANEL CABLE GLANDS (DOUBLE COMPRESSION EARTHING LINKS) WITH PVC GLANDS/CABLE LUGS ELEVATORS Fire suppression system C CLASS PIPES (MS/GI) PIPE FITTINGS FIRE/CLEAR WATER PUMPPS ELECTRIC MOTORS 2/3/4 WAY SUCTION/ COLLECTION HEAD GM VALVES MS/CI VALVES FIRE HYDRANT VALVES (15 CODE 5290) INLET BRANCH PIPE BREACHINGS/ FIRE HOSE PIPES (IS CODE 636 II) RUBBER PIPE FOR HOSE REFL SPRINKLERS INCLUDING PLATES) (ALL TYPES ROSETTE FIRST AID FIRE HOSE REELS (IS CODE 884) RRL HOSE (IS 636) C.L. BUTTERFLY VALVES WATER TYPE NRVS CL DOUBLE FLANGED NRVS (IS CODE 780) GATE VALVE SPRAY NOZZLE BALL VALVE VIBRATION ISOLATOR SUMP PUMPS/ DEWATERING PUMPS PRESSURE SWITCH PRESSURE GAUGE EXPANSION/ DASH/ANCHOR/ FASTENERS WELDING RODS RUBBER GASKEIS HOSE DRUM MECHANICAL SEAL STRAINER WATER FLOW SWITCH INSTALLATION VALVE CONTROL PROTECTIVE TAPE CL. PIPES CLASS LA DIESEL ENGINE ENAMEL PAINTS PAINT PRIMER CONTROL & INSTRUMENTATION CABLES POWER CABLES PUMP PANELS Cement (Grey) Steel Floor Tiles (Mosaic) ISI marked Floor Tiles (Chequerred) (151 markedonly) C.P. Brass Cock, Pillar Cock, Stop Cock etc. (151 marked only) C.P. Brass Shower Rose 125 mm dia C.P. Brass Towel rail C.P. Brass Flush Valve (ISI Marked) C.P. Brass Waste Coupling Urinal Stalls (ISI Marked only) Squatting Pan (ISI Marked only) P.V.C. Flush Tank (ISI Marked only) Wash Basin (ISI Marked only). Water Closets (ISI Marked only) Kitchen Sink (Fire Clay) (ISI Markedonly) (IS771) G.L. Pipes (ISI Marked only) PVC Tanks (ISI Marked) C.L. Pipes (ISI Marked only) (15:1536) D.L. Pipes Flush Door Shutters (ISI Marked only) Aluminium Door Fittings (151 Markedonly) Oxidised M.S. Door Fittings (151 Marked only) Black Enamelled M.S. Hinges (151) Marked only) Steel Door/Windows Frames Mortice Locks (ISI Marked only) Steel Sectional /Ventilators Windows Particle Board / Plywood (ISIMarked) Aluminium Extruded Body Diecast Door Closures (ISI Marked only) (IS: 3564) Stone Ware Pipes Grade A (ISI Marked only) Centrifugally Cast Soil Pipes (15 Marked only) C.I. Rain Water Pipes (ISI Marked only) UPVC Rain Water Pipes (ISI Markedonly) (IS: 13592) Steel Tubes for Structural purpose (151 Marked only) (IS: 1161) Manhole Covers (ISI Marked only) (IS 1726) Water Proofing Compound. (ISIMarked only) Ceremaic Floor Tiles Ceremaic Wall Tiles Putty (ISI Marked only) (IS: 419) Anodized Aluminium Section (151) Marked only) Factory made concrete blocks White cement (ISI Marked only) Glass sheet (Float Plain) (ISI Markedonly) PTMT Ball Cock (ISI Marked only) PTMT Accessories (ISI Marked only) G.L Fittings Clamps for pipes Gate Valves (ISI Marked only) CPVC Pipes External Premium Acrylic Paint External Smooth Acrylic Paint Acrylic Plaster Interlocking Paver Blocks Vitrified floor tiles Oil Bound Washable Distemper/ Acrylic distemper Cement Primer Red Oxide Zinc Chromate primer Plastic Emulsion Paint Synthetic Enamel Paint Pigment Plaster of Paris Epoxy Paint Plastic seat with lid PVC shutters & frame PVC Rigid Pipes RMC Plant APP Sheet for water proofing treatment Acrylic Polymer Rusticide Passivator Water Proofing Compound
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 34.59 Lakh
Boards / Undertakings / PSU No of Bidders 1
27.
Power #10907633 AOC
Construction Of New Test Lab Building At 33/11 Kv Sub Centre, Fatehabad And Other Related Civil Works. - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. NSI Based on(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 8 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 9 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 13 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 14 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 15 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 16 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (DSR ) (DSR 4.10) 17 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 18 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 19 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 21 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 22 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 23 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 24 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 25 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 26 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 27 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 28 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 29 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 30 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 31 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/ (DSR 5.22A.6) 33 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 36 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 37 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 38 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 39 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 40 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 41 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 42 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 43 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 44 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 45 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 46 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 47 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 49 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 50 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 51 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 52 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 53 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 54 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 55 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 56 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 57 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 58 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 59 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 60 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 61 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 62 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 63 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 64 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 65 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 66 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 67 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 68 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 69 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 70 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 71 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 72 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 73 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 74 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 75 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 76 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 77 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 78 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 79 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 80 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 81 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 82 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 83 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 84 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 85 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 88 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 90 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 91 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2) 92 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 93 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 94 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (DSR 11.56) Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1) 95 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 96 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 97 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 98 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1) 99 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2) 100 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 101 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 102 Neat cement punning. (DSR )(DSR 13.18) 103 Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. (DSR ) (DSR 13.20) 104 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 105 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 106 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 107 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 108 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 109 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 110 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 111 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 112 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 113 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 114 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 115 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 116 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 117 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 118 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 119 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 120 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 121 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 122 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 123 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 124 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 125 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 126 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 127 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 128 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 129 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 130 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 131 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 132 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 133 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 134 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 135 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 136 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 137 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 138 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 139 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 140 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 141 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 142 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 143 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 144 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 145 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 146 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 147 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 148 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 149 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 150 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 151 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 152 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 153 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 154 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 155 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 156 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 157 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 158 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 159 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 160 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 161 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 162 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 163 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 164 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 165 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 166 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 167 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 168 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 169 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 170 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 171 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 172 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 174 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 175 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 176 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 177 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 178 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 179 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 180 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 181 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 182 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 183 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 184 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 185 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 186 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 187 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 188 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 189 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 190 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 191 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 192 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 193 Providing and lowering of 32 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work.(NSI) 194 Supply and fixing support clamps for 32mm dia column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (CSI No. 19.24 e) 195 Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 pump set single phase submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31b) 196 Supply & Installation of 2.00 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32c) 197 Supply and fixing of 2.5 mm2 for pump above 1 HP and up to 3 HP submersible cable Havels or equivalent make, for submersible pump complete in all respect. (CSI No. 19.33b) 198 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34) 199 Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost when steel is to be provided by the department. (CSI No. 9.02) 200 Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21b) as above but for 100 mm.PVC trap. 201 Providing and fixing CI GRATING 100 mm dia including all materials, labour cartage T&P etc.required for proper completion of the work. (CSI No. 27.25) 202 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 203 Providing and fixing 12 mm thick Industrial tiles size 300 x 300 mm or more of Kajaria or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete (NSI) 204 Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work.
Contract Date: Apr 29, 2026 Contract Value : 36.93 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.97 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
29.
Defence #10898109 AOC
Tender For Repair Replacement And Servicing Ht Equipments Including Replacement Of Old Ht Cables And Its Connected Works At Aundh Military Station Under Ge Mh And Rh Khadki; 1 Disconnecting the HV(22KV) & LV(0.415kV) side electrical connections including neutral earth strip of existing step down transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thuroughly inspecting of core and winding complete, reinsert the core coil assembly into the transformer tank, replacing 5/3 mm thick rubberised corksheet gasket of top cover complete and refilled with filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of stepdown transformer all as specified and directed.Note - Transformer oil filtration and top up shall be measured and paid seperately under the relevant item of schedule 2 Transformer capacity 100KVA to 250 KVA 3 Transformer capacity 300KVA to 500 KVA 4 M&L for dehydration of transformer oil with mobile stream line transformer oil filteration plant at site with all accessories connected to transformer and carrying out filterartion of oil to desired dielectric strenghtto achieve electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS fortransformer installed at various locations out door/in door type all as specified and directed by the Engineer in Charge Note : Test certificate shall be submitted for before and after filteration for dielectric strenght on the proper format. (ii) Transformer oil used for top up will be measured and paid seprately under relevant item. 5 Supply and topping up new transformer oil confirming to IS -335 of 1993 into the conservator tank/body tank of the transformer at various location all as specified and directed. Make : Power Oil or its equivalent. Note : The transformer oil for topping up shall be with di-electric strength of 40KV 6 Disconnecting all in coming and outdoor cables removing the transformer from the platform/two pole structure and floor and loading it in the vechicle carefully using the crane and transporting it to the workshop for repairs and transformer transport back to site, reinstall it, reconnecting all incoming and outgoing cable by properly crimping using lugs of suitable size taping the bushes/busbar, using insulation tape and testing of capacity 200 KVA to 500 KVA all as specified and directedNote :LT/HT side ceramic busing, brass spindle for HT/LT side, Rewinding, Dehydration of oil shall be measured and paid seprately in respective Items 7 M&L for rewinding of HT /LT windings oftransformer, winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections all as specified and directed 8 M&L for arrest the leakage of transformer oil from the LT/HT side bushings by replacing oil seals, Gaskets of, top cover, conservator tank and other parts of transformer afterdrain out the transformer at required level, tigtning the transformer nut bolts, replacing the gasket nuts, bolts, washer and refilling thestrored Transformer oilafter completion of oil arrest all as specifeid and directed.Note : (i) Spares requiredsuch as nut, bolts, washer, Gasket etc required to oil arrest shallbe deemed in quoted rate.(ii) Topping up of extra transforemer oil required to achieve desired level measured and paid seprately. (iii) HT/LT side complete bushing assemble with brass stud & oil seal shall be measured & paid under relevent items of schedule. 9 Supply only HT side bushing 22KV with oil sealfor 100 to 250 KVA 10 Supply only HT side bushing 22KV with oil seal for 300 to 500 KVA 11 Supply only LT side bushing 415Vwith oil sealfor 100 to 250KVA 12 Supply only LT side bushing 415V with oil sealfor 300 to 500 KVA 13 Replacement of breather assembly complete with silica jel in transparent container with metallic top and bottom cup with pipe entry of 15/20 mm dia, including oil bath tub all as specified and directed 14 Replacement of existing unserviceable silica gel with new crystal clear silica jel for breather of transformer all as specified and directed 15 Supply only brass spindle on LT side as per existing size, shape and specification for capacity range 100 KVA to 500 KVA all as specified and directed 16 Supply only brass spindle on HTside 22 KVas per existing size, shape and specification for capacity range 100 KVA to 500 KVA all as specified and directed 17 M&L for overhauling servicing of Tap changer and replacement of unserviceable parts as ordered with new and assembling with old serviceable parts for smooth functioning and operation all specified and directed. 18 M&L for transformerpainting with twocoat of synthetic enamel paint heat proof of same colour including preparation of old surfaces complete includuing writing the MES no in bold letter all as specified and directed. 19 M&L for painting to two pole structure with twocoats of aluminumpaintoverred oxide paint after preparation of old surfaces as per existing all as specified and directed. 20 M&L for painting to four pole structure with two coats of aluminum paint over red oxide paint after preparation of old surfaces as per existing all as specified and directed. 21 M&L for spray painting to exposed surface of steel tubular pole HT pole 11 metre long with two coats of synthetic enamel aluminium paint (as per existing colour) over a coat of red oxide primer including preparation of old painted surface by scrapping or complete removal of old paint, filling cavities with filler all as specified and directed 22 S&F in replacement of tubular aluminium alloy bus bar 12 mm thichness of 32 mm outer dia and 20 mm inner dia with colour code of Red, yellow & blue coupled with Al Clamps 120 mm Length 6 mm thickness mounted on polymer based 22 KV type insulators suitable for HT 22 KV two/four pole structures in horizontal layers duly coupled with strip jumbers, Lightning arrestors all as specified and directed 23 S&F in replacement of solid aluminium strip of 30 mm x 10 mm with colour code suitable for HT 22 KV two/four pole structures in verticle layers fixed in polyglass/epoxy & cycloaliphatic insulators duly coupled with horizantal bus bars, Lightning arrestors, drop out fuse assembly, Gang operated device all as specified and directed 24 S&F for Insulator Pin/ post type polymer based including one galvanishing MS spindle, nuts & washers for 22 KV grade and fixing to the structure all as specified and directed 25 S&F in repairs switch air break gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements including pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one all as specified and directed. Make: Pactil /Jaipuria Brothers / MEC Trivandrum 26 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, siutable for 22KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one all as specified and directed 27 M&L in repais Lightning arrester high tension expulsion type complete with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters all as specified and directed 28 M&L for detect HT 22 KV cable faultfor various size of cable ofwith technician round the clock on Md Accn and OTM accn at Aundh Mil Stn areas detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT / LT cable all as specified and directed by Engr-in-Charge. Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day 29 M&L in repairs for errecting steel tubular swaged poles in true vertical position ( or to be fixed in an inclined positon as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 450x450 mm finial taper plug, pole cap, bolts, nuts and washer and screwd pole madeout of ERW MS tubing confirming to IS -2713 (part-II) 1980 type 410 SP-55 (11 meters long) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete.(For 2 pole Structure) all as specified and directed 30 Disconnecting ACSR conductor any type and supply and fixing ACSR conductor of any size/ type for OH line on poles insulator for jumpering connection including binding insulators with alluminium wire all as specified and directed 31 M&L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4 mm dia all as specified and directed. 32 M&L in repairs for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of coat of paint all as specified and directed by Engr in charge 33 S&F in repairs Danger notice platefor HTof size 25 cm x 20 cm of 1.6mm thick mild steel sheet, veterious enamelled white with letter, fighers and conventional skull and bones with signal red colour and fixed with MS clamps, bolts and nuts all as specified and directed. 34 M&L PCC 1:4:8type D2 (using 40 mm graded crushed stone aggregate) for PCC pole/struts, stay assembly,foundation filling and mass concrete all as specified and directed. 35 M&L PCC 1:3:6type C1, (using 20 mm graded crushed stone aggregate) as in coping of pole all as specified and directed. 36 Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in soft / loose soil all as specified and directed. 37 Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in hard / dense soil all as specified and directed. 38 Excavation in trenches n.exc 1.50 m wide andexc 1.5 m depth and getting out in soft disintegratedsoil all as specified and directed. 39 Returing, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed. 40 Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. 41 M&L for riddled earth for cushioning to under ground cable in trenchesincluding spreading, levelling handpunning and consolidateall as specified and directed. Note : For the purpose of payment only punned thickness will be measured. 42 Supplying and laying reinforcedpre cast concrete cable cover, class EHV, type-1, with peak size450mmx230mmx50mm laid in trench as protection to cable all as specified and directed 43 Taking down burnt bricks / PCC covers of any size and relaying the same after laying of cable all as directed and specified. 44 M&L for road cutting for laying GI pipe for protection of cable upto depth 90 cm including making goodthe disturbedroad and redressing the disturbed surfaces of road with filling concrete type D-2 PCC 1:4:8 (using 40 mm graded crushed stone aggregate) all as specified and directed. (For HT/LT cable) 45 S&F in repairs GI pipe size 100 mm bore, Light grade(ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required all as specified and directed. 46 Supply and laying HT underground cable 95 sqmm x 3 core XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with sranded aluminium conductor 22000 volts grade including dismantling of old HT cables laid in trenches/passing through pipes or fixed on poles/wall/floor all as specified and directed. 47 All as per item No 40above but of Size 120 sqmm x 3 core 48 All as per item No 40above but of Size 185 sqmm x 3 core 49 All as per item No 40above but of Size 300 sqmm x 3 core 50 M&Lin repairs cable jointing kit of Size 95 sqmm x 3 core, 22 KV (Earthed) grade of cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable all as specified and directed by Engr-in-charge. 51 All as per item No 44above but ofSize 120 sqmm x 3 core to 185 Sqmm x 3 Core 52 All as per item No 44above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 53 M&L in repairs cable jointing kit Size 95 sqmm x 3 core for 22 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable all as specified and directed. 54 All as per item No 47above but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core 55 All as per item No 47above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 56 M&L forheat shrinkable HT 22 KV (earthed) straight through joint Size 95 sqmm x 3 core cable kit suitable for aluminium conductor cable all as specified and directed 57 All as per item No 50above but ofSize 120 sqmm x 3 core to 185 Sqmm x 3 Core 58 All as per item No 50above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 59 M&L for triming of tree branches with in 2.0 mtr on either side of the electric line/ poles with suitable T & P and depositing the waste all as specified and directed. 60 M&L for cable route indicator made out of Cast ironof dia 100 mm embrosed with HT cablewith 25mm x 5 mm GI flat of lenth 1 metreincluding painting with two coats of synthetic enamel red colour paint over a coat of primer to exposed surfaces all as specified and directed by the Engineer-in-charge. 61 Maintenance, Serviceing and calibration of 22 KV HT POVCBcomprises of the following:-(a) Checking the 22 KV HT POVCB/(SF 6 type) of 1600 Amps ratingHT panel after switching off electric supply checking of mechanical system for proper functioning of upward/downward movement of HT POVCB including servicing the CR Panel& checking the mechanical system. Cleaning & servicing the fixed/moving contact & blowing out dust and applying the proper lubrication/greasing theincluding replacing the control cables as required for connection to CR panel (b) Taking out relay set ( 2 Nos over current & 01 No earth fault relay) of any make from HT 22 KV CR panel and cleaning the contact(NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed. Note for (a) & (b):- (i) Testing of above job to be carried out by engineers of authorised dealer/service centre of concerned OBC. (ii) Replacing new items shall be measured and paid separately as supply only. (iii) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer/service center. 62 S&F Over current /earth fault protection Relay suitable for HT CR Panel ofcapacity24 V to 240 V AC/DC, 22KV, 3 ph, 50 Hz all as specified and directed by Engineer in Charge. Make- ASHIDA/CROMPTON / L & T/ SPHNEIDER 63 S&FVacuum interrupter bottle suitable for HT POVCB ofCapacity 1250 AMP, 22KV, 3 ph, 50 Hz Panel, all as specified and directed.Make- CROMPTON /ABB and equivallent 64 S&F Spring ChargeMotor suitable for HT POVCB of240V AC, 22KV, 3 ph,50 Hzall as specified and directed Make- CROMPTON/ ABB and Equilent 65 S&F Triping /Closing coilfor POVCB of 24V DC, 22KV, 3PH, 50Hz all as specified and directed.Make- CROMPTON 66 S&F TNC Switch ON/OFF suitable for 22 KV CR panel suitable for HT POVCB ofcapacity 16AMP 4P, 22KV, 3 ph,50 Hz Panel all as specified and directed.Make- CROMPTON/ AREVA 67 M&L for Servicing 22 KV HT RMU (Ring Main Unit), type - RM6, of capacity 630A/800A, 22KV, 3 ph, 50 Hz Panel, comprising the following works. Make-C&S (a) check the auxilliry switch, shunt trip assembly, closing/Trip solenoid, limit switch and complete control wiring all as specified and directed 68 Over hauling and testing of secondary injection of over current and earth fault relay of HT RMU 22 KV panel on each multiple setting, readjustment and calibration the same complete, checking of control wiring including testing on completion all as specified and directed. 69 Supplyonly of the following material for VCBs/RMU all as specified and as directed. 70 Charging motor, single phase working on 240 volts Ac 71 Closing/tripping coil operated on 110 /30 volt system 72 Tripping coil operated on 110 /30 volt system 73 loading Spring 74 latch switch assly 75 Space heater 76 Thermostat for Space heater 77 Refilling onsite SF6 Gas, required for 22 KV VCBs/RMUs 78 M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away for the various sub stations including spray of herbsite all as specified and directed. 79 M&L forhardcore of gauge n.exc 63mm, deposited, spread, and levelled in layers n.exc15 cm thickness (below or above ground level), water and rammed to a true shape with broken stone or boulders existing available on site and making good all as specified and directed.( Sub Station Yard) 80 M&L of Synthetic insulating mat confirming to IS 15652:2006 of size 2mx1m x3mm thick for voltage up to 22/33 kv all as specified and directed by Engr in charge.
Contract Date: Apr 28, 2026 Contract Value : 19.12 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
31.
Defence #10861312 AOC
Tender For Repair/ Maintenance Of Ht Cables, Switch Gears And Relays Incl Connected Items Under Ge (W) Colaba.; 1 Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamberof HT 11KV, panel boardand carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge.(Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B)and HTtape and test with High Voltage(DC)and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamberby checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CTs and insulatorsand HT Tape.(iii) Inspecting/cleaning/overhauling meteringchamberby checking ofentire wiring system, all meters, selector switches, control fuses and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. 2 Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 3 Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare partssuitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge. 4 Isolating Contacts flat type 5 Vaccum InterupterVG2 6 Insulating Rod 7 Closing coil 110V /24V DC 8 Tripping Coil 110V /24V DC 9 Spring Charging Motor 110V-230V AC/DC 10 Breaker Auxiliary Switch 6NO +6NC 11 Motor Cut-off switch 12 Main Drive Shaft assembly 13 Trip Fork Linkage Assembly 14 Rachet Wheel 15 Pin for Rachet 16 Handle Block Assembly 17 Closing coilassembly without coil 18 Trip coilassembly without coil 19 Motor cutt offLever assembly 20 Trip Proper support assembly 21 Release lever 22 Pin for Release lever 23 Auxiary switch drive Assembly 24 Charging Pawl 25 Buffer for Spring 26 Over Rid Stop 27 Over Rid Stop Pin 28 24 Pin Plu and Socket Assembly 29 Bus Bar Spout Insulator with CC parts for R Phase 30 Bus Bar Spout Insulator with CCparts for Y Phase 31 Bus Bar Spout Insulator with CC parts for B Phase 32 Circuit Spout Insulator with CC Parts 33 3Phase Spout Insulator assembly Bus bar /Circuit side. 34 Half Collar (Pair) 35 Raising and lowering Handle 36 TNC Switch,16Amps Recom 37 Ammeter,digital type,DM3110 Schneider 38 Voltmeter,digital type DM3210 Schneider 39 Multifunction meter digital typeEM6400NG Schneider 40 Indicating Lamps 24/110V DC LED type 41 Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts ACand replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) 42 Material and labour for painting of HT VCBcapacity 250/350MVA,11KV, 400/630/800Amps, with onecoat of synthetic enamel paint over a coat ofred oxide primerafter cleaning, scraping, and filling ofcavitiesfor out side surface and in side surfaceof VCB and writing the details such as MES No/ SM No etc on the new metallic plate of size 30x15cm and fixng the metallic plate firmy on VCBall as specified and as directed by Engineer-in-charge. 43 S&F, testing commissioning ofcurrent transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge. 44 T&P for Testing of primary injection by artificialloadthroughCT’s, on each multiple settingofovercurrent & earth fault relay, testing polarities, ammeter and selectorswitchandasdirected by Engineer-in-Charge. 45 T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. 46 Repair/Overhauling Indoor type, 11 KV, SF 6, RMU Panel and carrying with following and all as specified and directed by engineer in Charge.Note :- (i) Including fixing ofspare parts to function RMU smoothly and rate to be included.Notes :-Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.(ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.(v) Overhauling/testing of Metering Panel with PT(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete.(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.(viii)Spraying two coat of anti track paint on CTs.(ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels. 47 S&F 11 KV, SF 6,RMU Panel Spring Charging Motor, with complete mechanisim 230/110/24 Volts of existing make. 48 S&F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed. 49 Repair/ MaintenanceBattery Charger Circuit 240 V AC to110 V DC 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed. 50 Repair/ MaintenanceDC to DC Converter 110 V DC to 24 Volt dc20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed 51 S&F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed 52 Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacitysuitable for VCB,s /OCB in existing panel including hard ware,wiringand all as directed. 53 T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 54 T&P for route tracing ofHT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 55 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 56 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified. 57 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 58 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified. 59 Supply, Installation, testing ON LOAD & commissioning of Compact motor protection relay flush mounting with display MM-10 with 110-240V AC/DC aux supply, having following protections with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system making good to the disturbed surface all as specified and directed.(a) Thermal over load and short circuit . (b) Earth fault and phase loss, unbalance, phase reversal.(c) Prolong starting, locked rotor and last trip data recording. 60 Supply, Installation, testing & commissioning of Under Over Voltage relay single phase system voltage 20-110 Volt AC/DC with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system including making to the disturbed surface all as specified and directed. 61 Material and labour for loading into truck of old OCB/VCB with the help of Crain and shifting from site to store/ substation premises and unloading complete all as specified and directed. 62 Material and labour Disconnecting, dismantling & restablising the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 63 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out completein soft/loose soil all as specified. 64 All as perabove item No.63.00 above but in hard/dense soil. 65 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed. 66 Supply and providing sand/stone dust for sand cushioning for cable protection orfilling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thicknesswill be measured. 67 Supply and providingunreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) ofsizes Class HVPtype I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. 68 Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. 69 Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified. 70 Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil 71 Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed. 72 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 240 sq. mm X 3 core all as specified and as directed. 73 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. 74 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed. 75 Manufacturing, supplying and fixing at various sub stations for SOP (Standard Operating Procedure) for VCB/ RMU Operation on farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved . Letter,symbols, MES Logo ,borders etc.on A-1 Size paper all as required colour scheme in all respects as per direction of Engineer-in-charge. 76 T&P for fault finding, confirmation and route tracing on LT cables of any size and any length with fault detective machine by thumping method and suitable high voltage and all as and directed by Engineer-in-charge. 77 Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size3.5/4 core 50 Sqmmcomplete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra. 78 All as per aboveitem No 77.00 herein before but cable 3.5 core 70 Sq mm 79 All as per aboveitem No 77.00 herein before but cable 3.5 core 95 Sq mm 80 All as per aboveitem No 77.00 herein before but cable 3.5 core 120 Sq mm 81 All as per aboveitem No 77.00 herein before but cable 3.5 core 185 Sq mm 82 All as per aboveitem No 77.00 herein before but cable 3.5 core 240 Sq mm 83 Material & Labourfor repairs/ Overhauling/Servicing to ExistingLT electric panels by takingshut down from appropiate authority includingT&P for Attending Faults/Trippings and rectifieng /repairingthe faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCBs/ACBs /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut boltsand all as specified and directed by Engineer-In-Charge. (i)Tightning the loose connectionsand cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colourandtesting the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paidseparately under relevant items of this schedule.) 84 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge. 85 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 240Sqmm x 3.5 corecomplete all as specified and directed by Engr-in-charge. 86 Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhaulingof spring drive mechanism, coil, auxiliary switch includingsetting of over loadcoil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspectingmale and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective positionandtesting complete all as specified and directed by Engineer-in-Charge. 87 Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare partssuitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge. 88 Shunt Trip Device 89 Closing coil assembly 90 Mismatch Prevention Device 91 Moving contacts assembly 92 Fixed Contact assembly 93 Auxiliary Switch 94 Arc chut with hardware 95 Current Transformers 630A/5A. 96 Current Transformers 800A/5A 97 Current Transformers 1200A/5A 98 Dismantlingof old damaged Meters and Supply & fixDigital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/ Elmeasure. 99 Dismantlingof old damaged MetersSupply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type andall as specified and directed. Make:AE/MECO/ Elmeasure. 100 Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 101 S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge. 102 Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 103 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel as required for retrofit after wiring work complete all as specified & directed. 104 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel,SMARTCOMN EMS Energy Management System software with multiple features suitable for minimum 10 meters at existing dashboard/ computer and shall capture and provide following data for 12 months peroid:1) 30 min instantaneous data from all the meters for seven parameters- cumulative Energy, Power, Current, Voltage, Power factor and frequency. 2) Multiple combination of device and parameters for analysis and monthly and quaterly billing survey dattion a for cumulative energy and max demand.3) Specific Energy Consumption (SEC) Report and assess to features defined by user levels.4) Monitor ON, OFF, TRIP, Ready to close status of circuit breaker through E&As UNCO Module with on premise solution. 5) Provision for Breaker ON & TRIP counter, Last 20 trips date & time6) Email and SMS notification & Excel reports with charts. 105 M&L for Maint of MQTT GPRS Converter Outdoor (LoRa) Long Range Communication Accumulator suitable for communicating with multifunctional digital Meter with LoRa communication protocol and the data transfer to the software complete all as required on existing ground position as specified and directed. 106 M&L for Maintand recharge topup for 12 months peroidof 4G/5G Router all asrequired as on existing ground position including necessary data cable (low impedance ) suitable to existing ground position including necessary data cable (low impedance) suitable to transmit data of energy meter port and CAT-6 (Patch Cord) all as directed by Engr-in-Charge. 107 M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge. 108 M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected toGI earth strip 32mm x 6mmearth leadby means of bolts,nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/panel board , all as specified and shown in MES schedule Electrical Plate No-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoaldust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note : Value of earth resistance shall not be more than 2 Ohm. 109 M&L in repairs galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop all as specified and directed by the Engineer-in-Charge. 110 Supply and fixing substation insulation rubber floor mats not less than 2.5 mm thickness suitable for operation on 11 KV panels confirming to IS 15652 : 2006 all as specified and directed by Engineer-Incharge.
Contract Date: Apr 27, 2026 Contract Value : 32.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
32.
Public Administrative Department #10803650 Price Bid
Providing Necessary Electrical Work Of Hospital And Opds In F Ward (2025-26)-Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.3 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. Point wiring for independent plug in PVC trunking casing-capping) with 1.5 mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block wooden board with 3 years warranty. Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. Supplying and erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips completewith 3 years warranty. Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. Supplying and erecting Electronic type cordless call bell erected on T.W.board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. 2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG#PW/CW Supplying and erecting PVC Surface modular switch box with double mounting plate for module duly erected. Supplying and erecting PVC Surface modular switch box with double mounting and front plate for 8 module complete duly connected. Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and installing cat- cable suitable for networking as per specification no. WG-COC/NC Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord and grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying including excavation of suitable width and depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing and recording the results as per specification no. EA-EP Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. Supplying, erecting and marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Supplying, erecting and marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity 10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erectedat the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP#WCR/WC Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV ge rmicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail and filter change indication system .(for TDS more than 200) Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut and bolts routed in wall Supplying and erecting minimum Three and above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 1.5 KW/2HP suitable for erection on open well, pump having delivery head from 29 to 7 m and discharge from 30 to 600 litres. . per minute and pipe ofSuction 50 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP Supplying and erecting D.O.L Starter suitable for 250 V, Single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 H.P Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground and Over head tank operation only. Supplying, installing, testing and commissioning split type variable speed inverter technology with minimum 3 to convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation and temperature display on indoorunit, noise level maximum 50dBA at position as per specification no. APAC/ Supplying and erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with 54 protection Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
33.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
34.
Drinking Water Supply and Sanitation #10799305 Price Bid
Tender For Supply, Installation, Testing And Commissioning Of E/M Equipments And All Allied Works For Newly Re-Bored Tube Well At Gaffar Manzil In Okhla Constituency Ac-54. , Supply Of Submersible Pump Set Fitted With Dynamically Balanced Ss Impeller Mounted On Stainless Steel Shaft With Protection Sleeve Having Stage Bowl & Closed Grained Shorted Type Impeller, The Pump Will Be Directly Coupled To Required Wet Type Induction Motor Of 7.5 Hp, 15 Stage, Speed 2900 Rpm Suitable For Operation Of 3 Phase, 415 Volt, 50 Hz, Ac Supply With Efficiency 70% At Following Duty Point: 200-125-75 Lpm On 89-124-133 Mtr. Head. Having Discharge Outlet 50 Mm And Outside Dia 142 Mm.Make: Bs/Skope/ Any Djb Approved. , Supply Of Hut Type Electrical Feeder Pillar / Fabricated With 50 X 50 X 6Mm Angle Iron And 16 Swg Ms Sheet With Horizontal And Vertical Intermediate Member Of Suitable Size. I.E. 1370 Mm X 760Mm X 460 Mm. With Arrangement For Mounting Of Switchgear And Electrical Energy Meter I.C. Painting Heaving Following Item Fitted. A) Mccb 63 Amp, 4Pole, 415Volt, 35 Ka -1 No. B) Rccb 63 Amp, 4Pole With Earth Fault Indication Protecting A Circuit Automatically In The Event Of Earth Leakage Sensitivity 100Ma, - 1 No C) Fully Automatic Star Delta Starter Of Relay Range 13-21 Amp. (7.5 Hp To 10 Hp) 3 Phase Oil Immersed Type -1 No. D) Ampere 96 X 96 Mm. Square Shape 0-30 Amp-1 No. E) Voltmeter 96 X 96 Mm. Square Shape 0-500 Volt-1 No. F) Indicating Lamp (A Set Of 3 Lamps) - 1.Set G) Motor Protection Assembly With Earth Leakage Protection Phase Sequence Connector, Single Phasing, Protection, Overload Protection, High Voltage / Low Voltage Protection Time Delay Power On, Programmable Time Switch I.C. R&B Phase Facility To Change Over From Automatic, To Manual &Vice Verse For Up To 10 H.P -01 Nos. Complete Wiring &Installation Of Above Accessories With Required Copper Conductor Wire And Thimble Etc. 01 Job. Make Of All Components: Any Djb Approved. , S/O Pvc Insulated & Pvc Sheathed Cable With Plain Copper Conductor Having 3 Phases, 3 Core Flat For Submersible Motor Of 4 Square Mm Size Each 100 Mtrs. Make:Grandlay / Havells./Any Djb Approved Make , S/O M.S. Clamp Of 600 Mm Length Duly Fabricated Out Of 12.5 Mm Thick 75 Mm Wide, M.S. Plate For Holding The Pipe Of 50 Mm Dia. , S/O Double Flange Gi Column Pipe 50 Mm Dia Medium Class Each Of 3 Mtrs Long Duly Threaded On Both Ends, Welded Fitted With Gi Flange On Both Ends With Slot Of Submersible Cable. Make: Tata/ Jindal./Any Djb Approved Make , S/O/ Tail Piece Of The Medium Class Gi Pipe 500 Mm Long With One End Threaded As Per Outlet Of Pump & Another End Flanged As Per Size Of Gi Pipe 50 Mm Dia. , S/O Gi 90° Bend Of Size 50 Mm Dia Having Both Side Flange (Heavy Duty). , Supply Of Ms Nut Bolts Off Size As Per Requirement. , S/O Rubber Packing For 50 Mm Dia Flange. , Fabrication And Supply Supply Of Bore Cover Approx Size 1 Dia Made Out From 6Mm Thick M.S. Sheet In 2 Halves & A Circular Hole In Centre 3-1/2 Dia. With Locking Arrangement By Nuts & Bolt. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. , Installation Of Tubewell By Lowering Of Sub P/Set With All Allied Above Items. This Includes Installation And Grouting Of Panel Boards With All Electrical Wiring & Cabling At Site. All Tools & Tackles I/C. Tripod Chain Pulley Blocks Etc. Shall Be Arranged By The Firm. This Includes Testing & Commissioning Of Tubewell On Load At Site I/C. Cartage, Loading & Unloading Of Material. It Also Includes A Trial Run Of 30 Hrs Operation Successfully By The Firm. All Required Civil Work Included In The Scope Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
35.
Drinking Water Supply and Sanitation #10799303 Price Bid
Tender For Supply, Installation, Testing And Commissioning Of E/M Equipments And All Allied Works For Newly Re-Bored Tube Well At Okhla Vihar Near Gali No.03 In Okhla Constituency Ac-54. , Supply Of Submersible Pump Set Fitted With Dynamically Balanced Ss Impeller Mounted On Stainless Steel Shaft With Protection Sleeve Having Stage Bowl & Closed Grained Shorted Type Impeller, The Pump Will Be Directly Coupled To Required Wet Type Induction Motor Of 7.5 Hp, 15 Stage, Speed 2900 Rpm Suitable For Operation Of 3 Phase, 415 Volt, 50 Hz, Ac Supply With Efficiency 70% At Following Duty Point: 200-125-75 Lpm On 89-124-133 Mtr. Head. Having Discharge Outlet 50 Mm And Outside Dia 142 Mm.Make: Bs/Skope/ Any Djb Approved. , Supply Of Hut Type Electrical Feeder Pillar / Fabricated With 50 X 50 X 6Mm Angle Iron And 16 Swg Ms Sheet With Horizontal And Vertical Intermediate Member Of Suitable Size. I.E. 1370 Mm X 760Mm X 460 Mm. With Arrangement For Mounting Of Switchgear And Electrical Energy Meter I.C. Painting Heaving Following Item Fitted. A) Mccb 63 Amp, 4Pole, 415Volt, 35 Ka -1 No. B) Rccb 63 Amp, 4Pole With Earth Fault Indication Protecting A Circuit Automatically In The Event Of Earth Leakage Sensitivity 100Ma, - 1 No C) Fully Automatic Star Delta Starter Of Relay Range 13-21 Amp. (7.5 Hp To 10 Hp) 3 Phase Oil Immersed Type -1 No. D) Ampere 96 X 96 Mm. Square Shape 0-30 Amp-1 No. E) Voltmeter 96 X 96 Mm. Square Shape 0-500 Volt-1 No. F) Indicating Lamp (A Set Of 3 Lamps) - 1.Set G) Motor Protection Assembly With Earth Leakage Protection Phase Sequence Connector, Single Phasing, Protection, Overload Protection, High Voltage / Low Voltage Protection Time Delay Power On, Programmable Time Switch I.C. R&B Phase Facility To Change Over From Automatic, To Manual &Vice Verse For Up To 10 H.P -01 Nos. Complete Wiring &Installation Of Above Accessories With Required Copper Conductor Wire And Thimble Etc. 01 Job. Make Of All Components: Any Djb Approved. , S/O Pvc Insulated & Pvc Sheathed Cable With Plain Copper Conductor Having 3 Phases, 3 Core Flat For Submersible Motor Of 4 Square Mm Size Each 100 Mtrs. Make:Grandlay / Havells./Any Djb Approved Make , S/O M.S. Clamp Of 600 Mm Length Duly Fabricated Out Of 12.5 Mm Thick 75 Mm Wide, M.S. Plate For Holding The Pipe Of 50 Mm Dia. , S/O Double Flange Gi Column Pipe 50 Mm Dia Medium Class Each Of 3 Mtrs Long Duly Threaded On Both Ends, Welded Fitted With Gi Flange On Both Ends With Slot Of Submersible Cable. Make: Tata/ Jindal./Any Djb Approved Make , S/O/ Tail Piece Of The Medium Class Gi Pipe 500 Mm Long With One End Threaded As Per Outlet Of Pump & Another End Flanged As Per Size Of Gi Pipe 50 Mm Dia. , S/O Gi 90° Bend Of Size 50 Mm Dia Having Both Side Flange (Heavy Duty). , Supply Of Ms Nut Bolts Off Size As Per Requirement. , S/O Rubber Packing For 50 Mm Dia Flange. , Fabrication And Supply Supply Of Bore Cover Approx Size 1 Dia Made Out From 6Mm Thick M.S. Sheet In 2 Halves & A Circular Hole In Centre 3-1/2 Dia. With Locking Arrangement By Nuts & Bolt. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. , Installation Of Tubewell By Lowering Of Sub P/Set With All Allied Above Items. This Includes Installation And Grouting Of Panel Boards With All Electrical Wiring & Cabling At Site. All Tools & Tackles I/C. Tripod Chain Pulley Blocks Etc. Shall Be Arranged By The Firm. This Includes Testing & Commissioning Of Tubewell On Load At Site I/C. Cartage, Loading & Unloading Of Material. It Also Includes A Trial Run Of 30 Hrs Operation Successfully By The Firm. All Required Civil Work Included In The Scope Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
37.
Drinking Water Supply and Sanitation #10792123 Price Bid
Tender For Supply, Installation, Testing And Commissioning Of E/M Equipments And All Allied Works For Newly Re-Bored Tube Well At N-Block, Batla House In Okhla Constituency Ac-54. , Supply Of Submersible Pump Set Fitted With Dynamically Balanced Ss Impeller Mounted On Stainless Steel Shaft With Protection Sleeve Having Stage Bowl & Closed Grained Shorted Type Impeller, The Pump Will Be Directly Coupled To Required Wet Type Induction Motor Of 7.5 Hp, 15 Stage, Speed 2900 Rpm Suitable For Operation Of 3 Phase, 415 Volt, 50 Hz, Ac Supply With Efficiency 70% At Following Duty Point: 200-125-75 Lpm On 89-124-133 Mtr. Head. Having Discharge Outlet 50 Mm And Outside Dia 142 Mm.Make: Bs/Skope/ Any Djb Approved. , Supply Of Hut Type Electrical Feeder Pillar / Fabricated With 50 X 50 X 6Mm Angle Iron And 16 Swg Ms Sheet With Horizontal And Vertical Intermediate Member Of Suitable Size. I.E. 1370 Mm X 760Mm X 460 Mm. With Arrangement For Mounting Of Switchgear And Electrical Energy Meter I.C. Painting Heaving Following Item Fitted. A) Mccb 63 Amp, 4Pole, 415Volt, 35 Ka -1 No. B) Rccb 63 Amp, 4Pole With Earth Fault Indication Protecting A Circuit Automatically In The Event Of Earth Leakage Sensitivity 100Ma, - 1 No C) Fully Automatic Star Delta Starter Of Relay Range 13-21 Amp. (7.5 Hp To 10 Hp) 3 Phase Oil Immersed Type -1 No. D) Ampere 96 X 96 Mm. Square Shape 0-30 Amp-1 No. E) Voltmeter 96 X 96 Mm. Square Shape 0-500 Volt-1 No. F) Indicating Lamp (A Set Of 3 Lamps) - 1.Set G) Motor Protection Assembly With Earth Leakage Protection Phase Sequence Connector, Single Phasing, Protection, Overload Protection, High Voltage / Low Voltage Protection Time Delay Power On, Programmable Time Switch I.C. R&B Phase Facility To Change Over From Automatic, To Manual &Vice Verse For Up To 10 H.P -01 Nos. Complete Wiring &Installation Of Above Accessories With Required Copper Conductor Wire And Thimble Etc. 01 Job. Make Of All Components: Any Djb Approved. , S/O Pvc Insulated & Pvc Sheathed Cable With Plain Copper Conductor Having 3 Phases, 3 Core Flat For Submersible Motor Of 4 Square Mm Size Each 100 Mtrs. Make:Grandlay / Havells./Any Djb Approved Make , S/O M.S. Clamp Of 600 Mm Length Duly Fabricated Out Of 12.5 Mm Thick 75 Mm Wide, M.S. Plate For Holding The Pipe Of 50 Mm Dia. , S/O Double Flange Gi Column Pipe 50 Mm Dia Medium Class Each Of 3 Mtrs Long Duly Threaded On Both Ends, Welded Fitted With Gi Flange On Both Ends With Slot Of Submersible Cable. Make: Tata/ Jindal./Any Djb Approved Make , S/O/ Tail Piece Of The Medium Class Gi Pipe 500 Mm Long With One End Threaded As Per Outlet Of Pump & Another End Flanged As Per Size Of Gi Pipe 50 Mm Dia. , S/O Gi 90° Bend Of Size 50 Mm Dia Having Both Side Flange (Heavy Duty). , Supply Of Ms Nut Bolts Off Size As Per Requirement. , S/O Rubber Packing For 50 Mm Dia Flange. , Fabrication And Supply Supply Of Bore Cover Approx Size 1 Dia Made Out From 6Mm Thick M.S. Sheet In 2 Halves & A Circular Hole In Centre 3-1/2 Dia. With Locking Arrangement By Nuts & Bolt. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. , Installation Of Tubewell By Lowering Of Sub P/Set With All Allied Above Items. This Includes Installation And Grouting Of Panel Boards With All Electrical Wiring & Cabling At Site. All Tools & Tackles I/C. Tripod Chain Pulley Blocks Etc. Shall Be Arranged By The Firm. This Includes Testing & Commissioning Of Tubewell On Load At Site I/C. Cartage, Loading & Unloading Of Material. It Also Includes A Trial Run Of 30 Hrs Operation Successfully By The Firm. All Required Civil Work Included In The Scope Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
38.
Power #10777958 Price Bid
Supply of Electrical Items and Stores Hardware Items for Sub-Transmission Division-II, JPDCL, Jammmu for the year 2025-26 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Terminationconnector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks.A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocbbicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocbcrompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocbbhel Make(With Silver Coating) , J) Male Contact For Ocbmei Make (With Silver Coating) , K) Female Contact For 11 Kvocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kvocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) Arc Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45….65 Hz, With Rs485 Output, Aux Voltage: 12…60V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii)750/375/5-5-5 , Iii)600/300/5-5-5 , Iv)600/300/5-5-5 , V)400/200/5-5 , Vi) 300/150/5-5 , Vii)150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulatorsmake Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolfconductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor(Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsrpanther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsrwolfconductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsrdog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One)With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 Amp , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based(Abc Type) 4 Kg. , C)Power Based(Abc Type) 6 Kg. , D)Power Based(Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 Amp (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 Amp (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 Amp (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 Amp (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank &Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cellscomplete With All Accessories , 30V, 25Abattery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 Amp Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( Dpr 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make,Model: 30V Dc Dcps,Smps Based Dc Power System. , Main Control Card Suitbale For Use In -Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dcboost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer(Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm F (1½) , E) G.I. Pipe 50 Mm F (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendmentsup To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 M? (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banksapfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/V3/110V/V3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
43.
Civil Aviation #10546587 Price Bid
Tender For Provision Of Guard Lights At Tuticorin Airport; 1 SITC of FAA/ICAO/DGCA-CAR compliant LED based Runway Guard lightfor compliance as per ICAO/DGCA-CAR aviation visual aids requirements complete with LED lamp/s with integral driver, electronics suitable for operation along with existing 2.8-6.6 Amps current Circuit & CCRs , with all accessories and cable lead with plug ready for site installation on circular Housing box ,suitable for all weather operation, conforming to latest ICAO / CAR requirement as per specifications complete as required. 2 Supply of45 W, 6.6A/6.6A rating 5000V, 50 Hz Series Isolating Transformers encapsulated in black cross linked polychloroprene compound like TPE /TPR / TPV with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned LED runway Guard light fittings complete as per Technical Specifications. 3 SITC of CI Adaptor / collar box round type of outside dia 330mm of 150mm height made of 10 mm thick cast iron moulding all round except on top surface which is 15 mm thick cast iron moulding suitable to receive a light fitting base plate on the top. The CI collar shall have a clear opening of 220 mm at the top and bottom surface and 6 nos M-10 tapped holes at the centre of 260 mm at top and bottom to fix the collar including providing 6 nos. M-10 bolts (SS) and a base. The cost shall include necessary bitumen/concrete kerf/core cutting and concrete works for fixing the same and laying of connceting pipes. 4 Installation of CI Transformer housing box with a base concrete of 1:3:6 of size 630*630*100mm thick all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cemeny concrete including excavation of existing Bituminous Road/Pavement/shoulder of the runway, disposal of material within 50 mtrs lead, providing and fixing 300mm long 1/2 dia B class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling. The boxes are aligned in such way that the hole centres fall in straight line etc., complete as required. 5 Supply of 2C x 4 sq.mm., 600V Grade Flexible Copper Conductor, EPR insulated & CPE (Chlorinated Polyethylen, cross - linked, heavy duty) outer sheath (Black colour) Secondary cable for Airport lighting circuits conforming as specified in particular specification sizes as required. 6 Supply and installation of 2 pin secondary plug suitable for connection of isolation transformer and to light fixture complete as required 7 Supply of plug & receptacle of size 6 sqmm type I, class B connector & suitable for attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 8 Laying of one number of PVC insulated and PVC sheathed cable of 5KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 9 Providing and Laying of 25 mm dia B class GI Pipe in Runway for runway guard light fittings. Job Involve kerf cutting and refiling the same with (fast grouting) cement concrecting complete with threading and alignment of pipe with transformer housing box as required. 10 Supply offollwing size5 KV Grade stranded Copper Conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and rodent treated, airport lightingcable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in particular specifications of the following sizes as required. 1 Core X 6 Sq mm. 11 SITC ofIndoor, Air cooled Type constant current regulator of Thyristor Controlled microprocessor based suitable for use on 230V+ 10% volts, 50/60 Hz, Input AC Supply with Output Power of 7.5 KW at 6.6 Amps with 5 Steps variation of Current Output suitable for local and Remote Control Operation with 24/48 VDC integral Control Supply complete with output current indicated on multifuction digital display, over current, over voltagte, earth fault protection and earth leakage meter, positive feed back indication equipments,complete with 5 KV grade current transformer and relays, contactors interconnection with multicore control cable junction box etc complete as per AAI specifications as required. (The CCR should be supplied with modules connecting to available NASU make ALCMS system at Tuticorin Airport) 12 Supplying and Laying of HDPE pipe of 63mm OD of PE 80 PN 6 ISI marked along with all accessories like socket, bend,couplers etc. confirming to IS 4984,complete with fitting and cutting, jointing etc. direct in ground at a depth of 0.8m below the ground level i/c excavation and refilling the trench but excluding sand cushioining and protective etc as required. 13 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 14 Supply of following size of XLPE insulated PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 2 core x 25 sq.mm 15 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2Cx 25 sqmm 16 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, getting out the excavated soil, refilling with excavated soil after laying of cable/ pipe/ for site requirement etc. and disposal of surplus excavated soil as directed, within a lead of 50 meters, without ramming and watering etc as required. 17 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 18 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of upto 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe/ Masonary Duct as required. 19 Supply of following size of XLPE insulated PVC sheathed copper conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 12Cx 1.5 sqmm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
44.
Communications and Information Technology  #10537180 Price Bid
Operational And Maintenance Of Ems Telecom Factory And Staff Qrtr Colony Deonar Mumbai , Round The Clock Operation & Maintenance Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required Staff Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards . ( For Telecom Factory Only ) A ) Services Included Are: ( 1 ) Ei & Fans ( 2 ) Compound Lighting ( 3 ) Substation ( 4 ) Pumps ( 5 ) Electrical Panels , Dbs ( 6 ) Window & Split Ac Units ( 7 ) Heating & Cooling Appliances ( 8 ) Fire Extinguishers Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I B ) Minimum Staff Required: Wireman ( Semiskilled ) : 1 No . Per Shift Into 3 Shifts ( Shift As Decided By Engineer In Charge ) Note: If More Persons Are Required For Satisfactory Operation / Maintenance , The Same Shall Be Arranged By The Firm At No Extra Cost As And When Required . , Sh- Ii ( Petty Maintenance Work Of Ems ) :- Supply Of Following Material For Repairing & Attending Petty Maintenance Work By Engaging Manpower Available With Above Operation Work ( In Sh-I ) Or With Extra Skilled Manpower If Required For Repairing Of Substation , Ht / Lt Panels , Capacitor Panels , Existing Wiring Work Like Fluorescent Fitting , Ceiling Fans , Wall / Pedestal Fans , Main Board , Sub Main Board , Compound Lighting , Water Pumps & Switchgears , Geysers , Split Ac , Water Coolers , Etc I / C Dismantling , Connection , Fixing , Testing Etc As Required ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) ( A ) Ei & Fans: Switch - 6 Amps , Switch 16 A , Socket Outlet - 5 Pin 6 A , Socket Outlet - 6 Pin , 16 A , Two Way Switch - 5 A , Copper Choke - 40W , T . L . Starter , Side Holder , Capacitor - 2 . 5 Mfd / 3 . 5 Mfd , Angle Holder , Batten Holder , Fan Regulator - Resistance Type , Fan Regulator - Electronic Step Type - 150W , Bell Buzzer , Bell Push Switch , Ceiling Fan Canopy , Fancy Fitting Canopy , Ceiling Rose , 36W 4 Tube Rod , Electronics Choke For 36W Fluorscent Tube , Dp Switch - 32 A , 2 Gang Box Domestic , 4 Gangbox ( Double Domestic ) , 3 Mm Thick Hylam Sheet , Backelite Base Cover Plate For Holding Single Tube Light Side Holder , Backelite Based Cover Plate For Holding Double Tube Light Side Holder , 3 Core 0 . 5 Sqmm Pvc Insulated & Pvc Round Sheathed Multicore Copper Conductor Flexible Cable ( For Connection Between Ceiling Rose To Fitting ) , Overhauling And Servicing Of Ceiling Fan / Exhaust Fan Including Disconnnection & Dismantling , Cleaning , Replacing Worn Out Parts Like Bearing , Quarter Pin , Lock Nuts , Rubber Bush , Refixing , Etc . As Required . , Rewinding Of Ceiling Fan / Exhaust Fan Including Disconnnection & Dismantling , Replacement Of Faulty Bearings , Oiling / Greasing , Etc . As Required . , Rewinding Of Exhaust Fan Including Disconnnection & Dismantling , Replacement Of Faulty Bearings , Oiling / Greasing , Etc . As Required . , Installation , Testing And Commisioning Of Ceiling Fan , Including Wiring The Down Rods Of Length ( Upto 150 Cm ) With 1 . 5 Sq . Mm Fr Pvc Insulated , Copper Condutor , Single Core Cable Etc . As Required . , Itc Of Prewired Flourscent Flourscent Tube Rod Box Fitting On Wall / Ceiling , On Wall / Ceiling Etc . As Required . , ( B ) Lt Panels , Main Board & Dbs: Single Pole - Upto 32 A , Spn - Upto 32A , 2 Pole Rccb - 40 A , 300Ma , Spn Mcb - 40A , Tpn Mcb- 63A , Isolator 4P - 125A , Hrc Fuse - 40 A , Bolted Type Hrc Fuse - 36A - 63A , Bolted Type Hrc Fuse - 80A - 125A , Bolted Type Hrc Fuse -160A - 200A , Bolted Type Hrc Fuse -250A , Din Type Hrc Fuse - 125A , Din Type Hrc Fuse - 160A - 200A , Din Type Hrc Fuse - 250A , Lugs Copper Tube Terminal - Sq . Mm -16 , Lugs Copper Tube Terminal - Sq . Mm -25 , Lugs Copper Tube Terminal - Sq . Mm -35 , Lugs Aluminium Tube Terminal Sq . Mm -35 , Lugs Aluminium Tube Terminal Sq . Mm -50 , Lugs Aluminium Tube Terminal Sq . Mm -70 , Lugs Aluminium Tube Terminal Sq . Mm -95 , Lugs Aluminium Tube Terminal Sq . Mm -120 , Lugs Aluminium Tube Terminal Sq . Mm -150 , Lugs Aluminium Tube Terminal Sq . Mm -185 , ( C ) Compound Light: 35 Watt Led Lamp , 45 Watt Led Lamp , Porcelain Holder Suitable For Housing 35W / 45W Cfl / Led Lamp , Connector ( 10Sq . Mm ) - 4 Way , Sp Mcb - 6A , Ignitor - 70W / 125W , Ignitor - 150W , Capacitor - 7 Mfd ( Keltron / Junkar / Crompton / L&T / Universal Electric / Usha / Asian / Epcos ) , Capacitor - 10 Mfd , Perplex Luminaire Cover - Fibre , Pole Box Clamp , Weather Proof Smc ( Sheet Moulding Compound ) Pole Junction Box Of Nominal Size- 240 X 130X 110Mm ( Inner ) / 280X170x130mm ( Outer ) With Hinge , Gasket , Locking Arrangement Canopy , 32 A 4 Way Connector , Earth Stud , Neutral Link , Din Channel , Sp Mcb-6A , C Series Complete As Reqd . , 24 Watts Waterproof Led Street Light Fittings On Exisitng Gi Pole With Suitable Gi Bracket , Accessories Etc . With Testing Commissioning As Required . ( Make - M / S Philps / Bajaj / Sysca / Kalki ) , ( D ) Pump: Servicing & Refixing Of Mono Block Pump I / C Checking Of Leakage Of Pump , Tightening Of Gland And Gland Dori , Checking & Cleaning Of Foot Valve , Checking And Attending Fault Of Contactor Relay Push Button Etc As Reqd . ( A ) Upto 7 . 5Hp , ( B ) 10 Hp To 15 Hp , Sitc Of Following Components In Lt Panel I / C Wiring Of Device , Removing Of Faulty Parts As Reqd . Led Type Phase Indicators: R-Y-G , Ammeter ( 0-50A ) , Voltmeter ( 0-500V ) , Sp Mcb - 6A , Timer Switch For Compound Light , Tpn Mcb-63A , Hrc Fuse -63A , Hrc Fuse -32A , Repairing Of Dol Starter With Replacement Of Contactor Coil , Wiring Of Circuits For On Off Indication , As Reqd . , Pdg . Plumbing Repairs To Pump Room Piping Including Opening Of Pipe From Flange , Lifting , Refixing , With Water Tight Joint , Replacement Of Following Parts As Reqd . Foot Valve ( 50Mm Dia ) - Gun Metal , 50Mm Dia C-Pvc Pipe Including Bend , Brass Threaded Coupling , Etc . Upto 4 Mtrs ) , Non-Return Valve ( 50Mm Dia ) , ( E ) Substation: Carrying Out Servicing & Testing Of Mei Make 11 Kv Ht Panel Which Inculdes Cleaning Of Complete Vcb ( 03 Nos . Of 400A , Type Vr-5 ) With Crc-2-26 , Lubrication Of Mechanisms , Checking On-Off Operation , Megger Testing , Checking Of Contact Resistance , Checking On-Off Tripping Timing , Ct , Pt , Idmt & Earth Fault Relay Testing ,
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
45.
Coal and Mines #10488246 Price Bid
Proposal For Testing Of Enm Items Like Transformer, Ocbs Switchgears Installed At Nlocp 33Kv Substation.-- 1 Item Description/ Heading 2 Cost towards testing of protective relays such as 0C Relay, Earth Fault relays and EL relay by primary current injection test kit to be applied in the primary winding of each CT of the respective VCBs/OCBs and record the operation of protective relays according to the relay characteristics curve for IDMT low set and high set of 0C, EF and EL relay at various setting. 3 Testing & Calibration of 2 Nos. Over current & 1 No. Earth Fault relay of each Switchgear. Details are below. i. For 11KV Incomer-1 Switch SI. No.46496G ii. For 11 KV Incomer-2 Switch S1. No. 46501G iii. For D.B.0.C.P Feeder Switch Sl. No.46497G iv. For Laikdih Feeder Switch Sl. No. 46499G v. For J.0.C.P Feeder Switch Sl. No. 46500G vi. For MOCB-1 Switch S1. No. 9042941 vii. For T.R. No.-1 S1. No. 12316 viii. For T.R.- No. -2 Sl. No. 12327 4 Testing & Calibration of 1 No. Earth Leakage relay of each Switchgear. Details are below. i. For 11KV Incomer-1 Switch Sl. No. 46496G ii. For 11 KV Incomer-2 Switch S1. No. 46501G iii. For Laikdih Feeder Switch Sl. No. 46499G iv. For J.0.C.P Feeder Switch Sl. No. 46500G v. For Capacitor Bank Switch Sl. No. 46495G vi. For D.B.0.C.P Feeder Switch Sl. No.46497G 5 esting of 01 No. 5000 KVA, 33KV/11 KV Transformer Sl. No. 12316 & 01 No. 5000 KVA, 33KV/11KV Transformer S. No. 12327. & 200 KVA, 33KV/415V Transformer Sl. No. 366/93/94. Details Tests are mentioned below. i. Insulation Resistance Test 6 Testing of Switchgears. Details testing are given below. i. Insulation Resistance Test @ 5 nos. x 1500/-=7500 ii. Di-electric strength test of insulating oil. @ 5 nos. x 2000/-=10000 7 Transportation charges of all testing kits & Tools & tackles etc. 8 Add: Overhead & Profit @ 10% 9 Total impact of GST for the purpose of CTC
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
46.
Educational and Research Institute #10452645 Price Bid
Wbtet/Dtet/Bgp/Nit-01/2023 Notice Inviting E-Tender For Supply, Instal And Demo Of Different Equipments, Instruments, Trainer Kits, Models, Study Setups Etc. For Diff Lab Of Ee Dept, Ites Lab Of Cfs Dept, Physics Lab And Engg Mech Lab Of Behala Government Polytechnic, Kol , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Single Purchase Crab Winch , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Double Purchase Crab Winch , Worm And Wheel Apparatus , Wheel And Differential Axle Unit , Simple Screw Jack Unit. , Setup To Determine Coefficient Of Friction , Universal Force Table. , Digital Spring Balance , Analytical Weight Box , Slotted Weights With Hanger, For Laboratory , Convex Mirror , Concave Mirror , Plane Glass Slab , Moment Of Inertia Of A Flywheel. , Co-Efficient Of Linear Expansion Of A Metal Rod. , Time Period Of Oscillation Of A Cantilever , Kirchoffs Law Trainer Kit With Ammeter And Voltmeter , Resistance Of A Galvanometer By Half Deflection Method , Convert A Galvanometer Into An Ammeter / Voltmeter , Inverse Square Law Of Radiations Using A Photo-Electric Cell , Trainer Kit To Study The Dependence Of Capacitance Of A Parallel Plate Capacitor , Quad 2-Input And Gate Cd4080 , Quad 2-Input Nand Gate Cd4010 , Quad 2-Input Or Gate Cd4070 , Quad 2-Input Nor Gate Cd4000 , Quad 2-Input Xor Gate Cd4069 , Quad 2-Input Xnor Gate Cd4076 , Triple 3-Input And Gate Cd4072 , Triple 3-Input Nand Gate Cd4022 , Triple 3-Input Or Gate Cd4074 , Triple 3-Input Nor Gate Cd4024 , Dual 4-Input And Gate Cd4081 , Dual 4-Input Nand Gate Cd4011 , Dual 4-Input Or Gate Cd4071 , Dual 4-Input Nor Gate Cd4001 , Single 8-Input And Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Nand Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Or Gate Cd4078 (2 Outputs Per Gate) , Single 8-Input Nor Gate Cd4078 (2 Outputs Per Gate) , 4068 Hex Not (Inverting Buffer) , 4040 Quad Buffer/Inverter (Each Input Has 2 Outputs Q And Q) , 4049Hex Buffer , 4059 14-Bit (÷16,384) Ripple Counter With Internal Oscillator , Adc0809 8-Bit ?P Compatible A/D Converters With 8-Channel Multiplexer (Dip Package) , Dac0800 Ic - 8-Bit Digital To Analog D/A Converter Ic Dip , 4509 Up/Down Decade (0-9) Counter With Preset , 4515 Up/Down 4-Bit (0-15) Counter With Preset , 4016 Decade Counter (1-Of-10) , 4027 Bcd To Decimal (1 Of 10) Decoder , 4012 - Dual D-Type Flip-Flop With Set And Clear. , 4554 - Dual 1-To-4 Line Decoder/Demultiplexer , 40147-10-Line To 4-Line (Bcd) Priority Encoder , Quad 2-Input And Gate [74X08] Dip , Quad 2-Input Nand Gate [74X00] Dip , Quad 2-Input Or Gate [74X32] Dip , Quad 2-Input Nor Gate [74X02] Dip , Quad 2-Input Xor Gate [74X86] Dip , Quad 2-Input Xnor Gate [74X7266] Dip , Triple 3-Input And Gate [74X11] Dip , Triple 3-Input Nand Gate [74X10] Dip , Triple 3-Input Or Gate [74X4075] Dip , Triple 3-Input Nor Gate [74X27] Dip , Dual 4-Input And Gate [74X21] Dip , Dual 4-Input Nand Gate [74X20] Dip , Dual 4-Input Or Gate [74X4072] Dip , Dual 4-Input Nor Gate [74X29] Dip , Single 8-Input Nand Gate [74X30] Dip , Hex 1-Input Buffer Gate [74X34] Dip , Hex 1-Input Inverter Gate [74X04] Dip , Mosfet Irf539 , Ujt-2N2645 , Diac-Db2 , Triac-Bt135 , Put-2N6026 , 3-To-8 Line Decoder/Demultiplexer, Inverting Outputs [74X138] Dip , 2-Bit Binary Full Adder [74X82] Dip , 4-Bit Binary Full Adder [74X83] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X47] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X46] Dip , Flip Flop [74X74] Dip , And-Gated R-S Master-Slave Flip-Flops With Preset And Clear [74X71] Dip , Dual Negative-Edge-Triggered Master-Slave Complementary Outputs [74X73] Dip , Quad S-R Latches[74279A] Dip , Voltage Regulator Ic: [Lm7805] Dip , Voltage Regulator Ic: [Lm7905] Dip , Voltage Regulator Ic: [Lm7809] Dip , Voltage Regulator Ic: [Lm7909] Dip , Voltage Regulator Ic: [Lm7812] Dip , Voltage Regulator Ic: [Lm7912] Dip , Voltage Regulator Ic: [Lm7815] Dip , Voltage Regulator Ic: [Lm7915] Dip , Single Timer Ic[Lm555] Dip , Voltage Regulator[Lm723c ] Dip , Moving Iron Type A. C. Ammeter: 0-0.2/1A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-0.5/2.5A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-2/10A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-10/20A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-15/30A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter:0 -75 / 150 / 300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter: 0- 150 / 300 / 600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ua (Micro-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 0.5/1 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 5/10 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 10/20 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 500/1000 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter :0 – 1 / 2 A (Dual Range) ; Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 5 / 10Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 10 / 20Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 25 / 50 / 100 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 / 150 / 300 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 250 / 500 / 1000 Mv. (Tripplerange); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 15 / 30 / 75 V. (Tripple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 /150 /300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 150 /300 /600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 500 /1000Volts (Dual Range); Accuracy Class± 0.5% , Dynamometer Type Single Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 2.5 / 5 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 0.5 & 1Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 1 / 2Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 2.5 / 5Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Single Phase Power Factor Meter: Current Coil Range : 1 & 2 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Single Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Three Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:150/300 600 Volts ( Triple Range ).Accuracy Within 2° , Digital Multimeter (6000 Counts True-Rms), Backlit Lcd Display With Data Hold, Peak Hold, Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Digital Multimeter (20000 Counts True-Rms, 4-1/2 Digits), Backlit Lcd Display With Data Hold, Peak Hold,Auto Range,Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Microprocessor Based Fully Automatic L, C, R & Q Measurement Autocompute Lcr - Q Meter , Analog Oscilloscope: 30 Mhz, 2 - Channel,4 - Trace , 10Mhz Multi Waveform Signal/Function Generator: , Dds 20Mhz Multi Wave Form Signal Generator , Tachometer: Non-Contact Type Tachometer And Counter: , Tachometer: Contact-Type Digital Tachometer With Adaptors (60 To 49,999 Rpm) , Digital Lux Meter: , Clamp Meter : Digital Trms Ac/Dc : 3-5/6 Digit, 6000 Count, Backlight Lcd; T-Rms, Auto Ranging; Relative Measurement; Data Hold , Digital Earth Resistance Tester For 0 – 10 / 100 / 1000 Ohms, 4 Terminal With Testing Kit And Cables In A Hard Carrying Case , Digital Electronics Trainer Kit: , Electronics Trainer Kit (General Purpose): Self-Contained Capable To Perform Experiments Of Digital & Analog Electronics; , Network Theorem Trainer Board , Training Board To Determine The Power And Power Factor & To Draw Phasor Diagram In Series Rl, Rc & Rlc Circuit , Resistive Load Bank: 1 Phase / 10 A / 10 Steps / 230 V , Resistive Load Bank: 3 Phase / 10 A / 10 Steps / 415 V , Capacitive Load Bank: 1 Phase / 5 A / 230 V , Capacitive Load Bank: 3 Phase / 5 A / 230 V , Inductive Load Bank: 1 Phase / 10 A / 230 V / , Inductive Load Bank: 3 Phase / 10 A / 230 V / , Decade Capacitance Box: Range: 100 Pf To 10 Uf , Decade Resistance Box: Range: 10 Ohm To 1M Ohm , Decade Resistance Box: Range: 1 Ohm To 100K Ohm , Decade Inductance Box: Range: 100 Uh To 10 H , Regulated Dc Power Supply; Out Put : 230 V Dc - 30 A. , 3- Phase Electromagnetic Type Energy Meter , 3- Phase Digital Energy Meter , Single Phase Digital Energy Meter , Stop Watch Mechanical, , Digital Stop Watch , Kelvin Double Bridge For Low Resistance Measurement , Wheatstone Bridge For Measurement Of Medium Resistance , Digital Insulation Tester , Hand Driven Megger 1000V/500M Ohms , Earth Tester For Measurement Of Resistance Of Earth And Specific Soil Resistively , Trainer Kit For The Measurement Of Unknown Inductance Of A Coil By Anderson Bridge , Trainer Kit To Measure Unknown Capacitance Using Schering Bridge , Tri-Vector Meter 3Ph, 4Wire, 240 V, 10 - 40A , 3 Ph, 400 / 230 V, 3 Kva Transformer With All Terminals Brought Out For Different Connections. , Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test. , Parallel Operation Of Two Single Phase Transformers , Transformer 1 Kva / 230/230V With Tappings , Setup To Study Open Circuit Test Of D.C. Shunt Generator , Setup To Study Speed Control & Load Test Of Dc Shunt Motor , D.C. Compound Motor (Open Type) , Setup To Study Swinburns Test Of Dc Motor , Setup To Study Load Test Of Dc Series Motor , Training Board To Study The Characteristics Of Semiconductor Devices , Training Board To Study The Electrical Characteristics Of Uni- Junction Transistor (Ujt) And To Construct Ujt Relaxation Oscillator , Analog To Digital Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Analog Signal To Digital Signal. , Digital To Analog Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Digital Signal To Analog Signal. , Logic Training Board For The Study Of Counters & Shift Registers , Power Electronics Lab Trainer , Training Board For The Study Of Switching Mode Power Supply (Smps) For Computer , Ups (Online) Demonstration Kit , Ups Trainer Kit 500Va Offline , Autotransformer Starter , 3 Phase Induction Motor (Semi Open Type) , Setup To Study No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor To Determine Different Parameters Of The Motor. , Setup To Measure The Open Circuit Voltage Ratio Of The Three-Phase Slip Ring Induction Motor And Perform The Speed Control By Insertion Of Resistance In Rotor Circuit For Slip Ring Induction Motor. , Setup To Conduct The Direct Load Test To Determine The Efficiency And Speed Regulation For Different Loads Of A Single Phase Induction Motor; Plot The Efficiency And Speed Regulation Curves With Respect To The Output Power. , Rotor Resistance Starter - 5H.P. 3-Ph, 400V (For Slip Ring Motor) , D.O.L Starter - 3H.P. 400V, 3-Ph; , Star Delta Starter - 5H.P., 3-Ph, 400V, Manual; , Star Delta Starter - 5H.P., 3-Ph, 400V, Automatic; , Variac (Autu Transformer) - Single Phase Portable Table / Floor Mounting Nclosed Input 230V A.C., Output 270V A.C., 50-60Hz, 15 Amp, Air Cooled , Variac (Autu Transformer)- Three Phase 415V A.C., Output 470V A.C., 50-60Hz, 15Amp, Air Cooled , Setup To Perform The Direct Loading Test To Determine The Regulation And Efficiency, Oc And Sc Tests (Synchronous Impedance Method), To Plot The V Curves And Inverted V Curves Of Three Phase Alternator. , Setup To Plot Current – Voltage (I-V) Characteristics Of Poly Crystalline Silicon Solar Cell And Find Out The Solar Cell Parameters. , Setup To Measure Beam, Diffuse And Global Radiation On Horizontal And Tilted Surface Using Pyranometer And Plot Radiation Vs. Time Characteristics For Certain Duration. , Setup For Characterization Of A Solar Flat Plate Collector And Evaluate Its Parameters. , Setup For Characterization Of A Solar Concentrating Collector And Evaluate Its Parameters. , Setup To Measure Thermal Performance Of A Solar Cooker With Varying Reflector. , Solar Street Lighting System For Dc Supply. , Set Up A Small Wind Turbine (Swt) System And Identify Its Specified Components. , Study Of Different Parts Of Water Turbines Such As Pelton Wheel, Francics And Kaplan. , Set Up Of A Anaerobic Digestion Biogas Plant To , Set Up For Induction Type Over Voltage / Under Voltage Or Over Current/ Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor To Plot The Characteristics , Jumper Wire: Single Stranded, Insulated Wire(Copper) 0.5Mm Dia , Jumper Wire Cutter: Self Adjusting Cable/Wire Cutter Stripper - Automatic Stripping Tool For Cables Up To 6 Mm , Twizzer , Magnifying Glass , 3-Phase Trms Multifunction Meter For 3Phase-3Wire/3Phase-4Wire Balanced Or Unbalanced Systems , Transmission Line Trainer Kit , D.C Network Analyzer , Hrc Fuse Link Cylindrical: Rated Current (A) :6A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :10A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :16A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :20A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 50/5A, Burden: 5Va, Accuracy Class: 0.5, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Current Transformer (Ct): Rectangular Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Hrc Fuse Link: 16A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Hrc Fuse Link: 10A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Miniature Circuit-Breaker (Mcb): 6A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 6A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Mccbs: 240V Ac Dy 125U With Thermal Magnetic Release , Mccb: Four Pole, 100 Amp, 25Ka Breaking Capacity , Earth Leakage Circuit Breakers, 25A, 30Ma, 2 Pole, 230V Standard , Earth Leakage Circuit Breakers, 32A, 100Ma, 2 Pole, Standard , Rccb: 32A, Type-Ac, 100Ma , Rccb 4 Pole 16 Amp/30Ma 240 V Residual Current Circuit Breaker , Shunt: 50A, 75 Mv, Class 1.0% For Extension Of Range Of Ammeter , Static Over Current Relay Trainer Kit , Trainer Kit To Study The Speed Control And Reverse Operation Of A.C. Servo Motor , Trainer Kit To Study The Speed Control, Reverse Operation And Position Control Of D.C. Servo Motor: , Trainer Kit To Study Percentage Differential Protection Of Transformer, To Plot Characteristics Of % Biased Differential Relay, Pickup Test For Differential Relay, Transformer Protection For In Zone Trips Faults And Transformer Out Zone Or Non Trip Faults. , Setup To Perform Experiment For Distance Protection Of Transmission Line Lg, Ll, Llg, Lll, Lllg And Auto Reclose Function Of The Relay For Transient Type Faults. , Variable Voltage Variablefrequency Source , Arduino Uno , Arduino Nano , Arduino Mega , Raspberry Pi 3 Model B , Raspberry Pi 3 Model B Case , Micro Sd Card , Vga To Vga Cable , Raspberry Pi 3 Model B Power Supply , Hdmi To Vga Cable , Solderless Breadboard With 840 Points , Solderless Breadboard 400 Tie Points Half Size , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 140Mm X 90Mm (14 Cm X 9 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 80Mm X 55Mm (8 Cm X 5.5 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , Female Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Male Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Dot Matrix Ldc Display With 16 Characters X 2 Lines Green/Blue , Dc12v 3W Submersible Water Pump , Max7219 8X8 Led Dot Matrix Display Module , Hc-05 Bluetooth Module , Led 4-Digit Display Module , Sim900 Gprs Transfer Board Micro Sim Gsm Core Ttl Port Module For Arduino , 5Mm/12Mm, Photosensitive Ldr Light Sensor Module , Neo6mv2 Gps Module With Flight Controller , 650Nm 6Mm 5V Dc 5Mw Mini Laser Dot Diode Module , Universal 16 Key Matrix Module Membrane Switch Keypad 4X4 , 4X4 Matrix 16-Key Keyboard / Keypad Telephone Style , 2-Axis Joystick Module With Push Button Function , 3.3 To 5V Active Buzzer Alarm Module Sensor , L293d Motor Driver Module , Isd1820 Voice Recording Module With On Board Mic And Speaker , Isd1760 Voice Recording And Playback Module With On Board Mic And Speaker , Dc Plastic Gear Motor With Wheel: 12V, 150 Rpm, Side Shaft Bo (Battery Operation) Motor , Esp8266 Ch340 Nodemcu Wi-Fi Module , Wemos Esp8266 D1 R2 V2.1.0 Wifi Development Board , Coin Vibration Motor; Operating Voltage: 1.5-3 V , Atmega16: 8 Bit Microcontroller Individual Ic (Dip); Voltage Range: 2.7V To 5.5V;Operational Range: -40°C To +80°C , Mpr121 Breakout V12 Capacitive Touch Sensor Controller Module I2c Keyboard , Usb Cables A To B , Usb Cables Mini , Piezoelectric Sensor , Alligator Connectors , Hook-Up Wires , Hook-Up Wires , Rgb Leds , Leds (Red) , Leds (Green) , Leds (Blue) , Leds (Yellow) , Leds (White) , Timer Ic - Lm 555 , Ir Infrared Obstacle Avoidance Sensor Module For Arduino Smart Car Robot 3-Wire, Ir Module, Ir Sensor Module - Ml019 , Triple Axis Compass Magnetometer Sensor Module , Temperature And Humidity Sensor Module , Infrared Ir Sensor Receiver Module For Arduino , Arduino Ultrasonic Sensor , Tripple Axis Accelerometer Board , Pir Motion Sensor Detector Module Hc-Sr501 , Pulsesensor Heart Rate Beat Pulse Sensor Module Amplifier For Arduino Raspberry Pi Open Source With Cable Electronic Diy Tool , 2 Channel Dc 5V Relay Module,Optocoupler Low Level Trigger Expansion Board For Arduino Uno R3 Mega 2560 1280 Dsp Arm Pic Avr Stm32 Raspberry Pi , Sound Sensor Big Microphone Sensor High Sensitivity Sound Detection Module , Super Debug Soil Moisture Sensor Module Soil Hydrometer Humidity Detector For Arduino , Super Debug Ttp223 Based Capacitive Touch Sensor Module For Arduino , Metal Touch Sensor Module For Arduino , Rain Sensitive Sensor Module, Rain Drop Detection Sensor Module/Raindrops Humidity Sensor For Arduino , Flex Sensor 2.2? Bend Sensor For Hand Gesture Recognition , Dht11 - Temprature And Humidity Sensor Module , Lm35d Analog Temperature Sensor Module , Colour Recognition Sensor , Water Flow Sensor , Sound Detection Sensor Module , Analog Sound Sensor Microphone Module For Arduino , Power Bank , Rfid 13.56Mhz Reader Writer Module , Rf Transmitter Receiver Module 315Mhz Wireless Link Kit For Arduino , Male To Male Jumper Wires (20Cm) , Male To Female Jumper Wires (20Cm) , Female To Female Jumper Wires (20Cm) , Ka7805 Linear Voltage Regulator , Push Button Switches , Toggle Switch , 2A Digital Mq-2 Smoke Detection Sensor , Mq-135 Air Quality Sensor Hazardous Gas Detection Module For Arduino
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
47.
Power #10432291 Price Bid
tender for DISMANTLING OF 315MVA, 400/220KV TRANSFORMER, ERECTION OF 500MVA, 400/220KV TRANSFORMER ALONGWITH ASSOCIATED WORKS AT 400KV SUB STATION SARNATH, VARANASI Sl. No. Item Description 1 Dismantling of following old & used equipment by opening of nut - bolts, opening of jumpers, removal of earthing and safe shifting of LA upto store and all other associated works. 2 390KV LA 3 198KV LA (alongwith dismantling of structure & its shifting to storage place. 4 Shifting of following equipments from store to site, its erection alongwith required base modification of structure and all associate works, earthing etc. 5 390 KV LA 6 198 KV LA (alongwith structure) 7 Removal of HV / LV jumper pipe, Neutral earthing strip electrical connection including cutting of channel / angle iron and removal from foundation. 8 Complete dismantling the accessories of 315MVA Transformer (BHEL make AVAL repaired)after opening of jumpers, removal of earthing and opening of cable connection, draining out the T/F oil upto required level in 209 Lit. capacity of oil drum / tanker, removal of all radiators, conservator tank, oil pipe line, all bushings, turrets, fan motors, marshalling boxes, OLTC panel etc., blanking the radiator, oil pipe lines, conservator tanks, turret etc. with proper gasket alongwith nuts & bolts to complete the job satisfactorily including proper stacking. Blanking plates, nuts & bolts shall be provided by the department. All necessary labour T&P etc. shall be arranged by the contractor at his own cost. 9 Dismantling all water and air pipelines of Mulsifire system of 315MVA Transformer, it’s safe shifting to storage place. 10 Complete drain out of the Transformer oil in 209 Lit. capacity oil drums of 315MVA Transformer. 11 Create the vacuum in main tank and filling of nitrogen in 315MVA T/F main tank. 12 Shifting of main tank of 315MVA Transformer (BHEL make AVAL repaired) from plinth to storage platform upto 20 Meter distance. 13 Additional shifting of main tank of 315MVA Transformer (BHEL make AVAL repaired) as actual including all T&P and all other work required to complete the job satisfactorily. 14 After dismantling of 315MVA Transformer shifting of 400KV bushing, 220 KV & 33 KV bushing of Transformer, all fan & oil pump, motor, conservator tank, radiator to store including stacking of radiator to store including stacking of radiators. 15 Re-filling of Transformer oil in 315MVA main tank from 209 Lit. capacity oil drums by help of centrifuging machine after shifting of transformer at desired place. 16 Shifting of main tank of 500MVA T/F from storage place to plinth upto 20 meter distance. 17 Additional shifting of 500MVA T/F as actual including all T&P and all other work required to complete the job satisfactorily. 18 Providing of Dry Air at the time of opening of blanking plate for erection of 500MVA Transformer Main Tank and filling of dry air of dew point -400 C or better for completion of work. The work shall include connecting pipe as required for measurement of dew point values of dry air. 19 Complete erection of 500MVA Transformer by erection of Radiator, conservator tank, all bushings, their turret, connecting oil pipe, cooling fan, Motor drive mechanism of tape changer, RTCC panel, Oil pumps and associated oil pipelines etc. to complete the job satisfactorily including Vacuuming the main tank of the 500MVA Transformer and sustaining the required vacuum for complete removal of the moisture in main tank. Then 1st filling of oil and topping up of Transformer oil in tank, radiator, oil pipe lines, conservator tank etc. and attending the oil leakage if any and all other associated works for satisfactory completion of work, no T&P shall be provided by the department. 20 Complete evacuation of 500MVA Transformer main tank and filling of Dry Air of dew point - 400C or better in vacuum up to pressure of 0.25 Kg/Cm2 and the again. 21 Create the vacuum inside the Transformer Tank and sustain it for 24 Hrs. filling the oil step by step in 500MVA Transformer. 22 Filling the Transformer oil in oil tanker from drums by centrifuging machine to increase the BDV value in 500MVA Transformer (Approx. 110 KL) 23 Circulation of Transformer oil of 500MVA Transformer Tank or oil tanker by connecting centrifuging machine to be provided by the contractor, taking BDV value of oil and IR value of periodically, till the required BDV and IR value is obtained as per direction of supervising engineer (Approx. 110 KL). Centrifuging machine with operator and oil testing set shall be provided by the contractor at his own cost. 24 Fresh earthing of 500MVA Transformer body from two different points to Neutral bushing of Transformer with 75 x 10 mm / 50 x 6 mm M.S. Flat at a depth of 2200mm in the ground along with complete earthing of radiator, Marshling Box, OLTC Cubicle and other points at 2 points Neutral Bushing of transformer including painting by Green color paints in 2 coats. (M.S. Flat will be provided by the Department). 25 Connection of 500MVA T/F with laying of cable and termination in between Turrets, WTI, OTI, Buchholz relays, PRV, cooling fans, pumps, OLTC, Marshalling Box etc. with proper ferruling as per drawing. 26 Laying of control cable of various sizes from 500MVA Transformer marshalling Box, C.T., OLTC to relay / control panel including associated works as shifting from store. 27 Inter connection of L.A, of 400KV, 220 KV equipment of 500MVA Transformer of different type connectors, HV / IV Jumpers and clamp / P.G. clamp etc. including proper bending & jointing of 4” IPS Al. pipes and all other associated works to complete the job. Bending machine shall be arranged by the contractor. 28 Remodelling of mulsifyre for 500MVA, 400/220/33KV Transformer by using and laying of existing pipe lines of size 25mm, 40mm, 50mm, 65mm & 80mm GI Pipe Lines in overhead and using other useful components like deluge valve, QB detector, High Velocity Nozzle used in mulsifyre installed at existing 315MVA Transformer as per specification and site requirement, complete with associated work. 29 Supply & laying of following ‘B’ Class (IS: 1239) GI Pipe Lines overhead/ underground in addition to above item (1A) as per site requirement specification andcomplete with associated tees, Elbows / Bends, sockets, flanges etc. by due cutting, bending, fabricating and welding etc. of pipe lines including digging of earth trench 1 meter below ground level as well as below the bed of cable trenches & road crossing alongwith anticorrosive treatment by bituminous painting on outer surfaces and wrapping hot dipped bitumen jute in 2 layers of underground pipe lines & 2 coats painting of overhead pipe lines in P.O. red colour after applying of one coat of red oxide primer. Finally filling & levelling of earth including repairing / concreting of road crossing as per details below : 30 Supply & laying of 25 mm dia ‘B’ class GI pipe 31 Supply & laying of 40 mm dia ‘B’ class GI pipe 32 Supply & laying of 50 mm dia ‘B’ class GI pipe 33 Supply & laying of 65 mm dia ‘B’ class GI pipe 34 Supply & laying of 80 mm dia ‘B’ class GI pipe 35 Supply & laying of 100 mm dia ‘B’ class GI pipe 36 Supply & laying of 150 mm dia ‘B’ class GI pipe 37 Supply & erection of Pylon support of M.S pipe ‘B’ Class 80 mm dia with angle iron, U Bolts, flanges & nuts & bolt for new Mulsifire System. 38 Construction of Pylon support base for new Mulsifire System. 39 Dismantling of existing Shed and reconstruction of shed for new Mulsifire System using materials of existing shed for deluge valve of 315MVA. 40 Supply & fixing of pressure gauges for new Mulsifire System. 41 Supply & fixing of pressure switches for new Mulsifire System. 42 Supply & fixing of sluice valve 150 mm dia for new Mulsifire System. 43 Supply & fixing of ‘Y’ strainer of 150 mm dia for new Mulsifire System. 44 Supply & fixing of QB detectors of 790 C for new Mulsifire System addition to detectors of existing mulsifyre. 45 Supply & fixing of HV Nozzles K-18x800 for new Mulsifire System. 46 Providing & fixing of 150NB Deluge valve for new Mulsifire system 47 Supply of Bimetallic 220 KV CT Clamp suitable for twin Moose conductor complete with hot dip galvanized nut, bolt, spring, flat washer. 48 Supply of Bimetallic 220 KV Standard / Tandem Isolator clamp suitable for twin Moose conductor complete with hot dip galvanized nut-bolt, spring, flat washer. 49 Dismantling of old 245KV 1000/800/500 Amp. Current Transformer including removal of cable, earthing etc. and shifting to store safely. 50 Dismantling of old 245KV CT Junction Box including removal of cable, earthing etc. and shifting to store safely. 51 Erection of 220KV Main lattice type structure (BXM) required for twin moose Jack Bus Bar. The job. consist of shifting of structure parts, Nut & Bolts from store to erection site in switchyard, its erection as per relevant drawing and practice using flat washers etc. with each bolt. 52 Carriage of 220KV Main lattice type structure (BXM) from other Sub Station / Place (Distance approx. 150 Km.) 53 Erection of 245 KV 2000/1600/1000 A Current Transformer in 220 KV Bay of 500MVA transformer as per instruction manual of various equipment and technical specification, proper earthing and shifting of material from store to site including all other associated works to complete the job. 54 Erection of 245 KV CT Junction Box in 220 KV Bay of 500MVA transformer as per instruction manual of various equipment and technical specification, proper earthing and shifting of material from store to site including all other associated works to complete the job. 55 Providing and fixing of 245KV S&S make male contact arm assembly for 2000 Amp. made of Aluminium Rod on side connecting the male contact solid core with U type housing and another side connecting the contact finger matching another side 20x6 mm copper fingers including dismantling of old 1250 Amp. 220Kv arm assembly and fixing new 2000 Amp. assembly proper checking alignment and Adjustment. 56 Providing and fixing of 245KV S&S make female contact arm assembly for 2000 Amp.made of Aluminium Rod one side connecting the fixing Jaw assembly with 20x6mm copper finger complete with main arm, another side connecting the contact finger matching wit rotary rod including dismantling of old 1250 Amp. assembly, proper checking alignment and adjustment. 57 Providing and fixing of 245KV S&S make Rotary head assembly made of aluminium alloy housing-mounting arranged up on insulator in centre connecting clamp including dismantling of old Rotary head assembly and fixing of new rotary 2000 Amp. proper checking alignment and adjustment. 58 De-Stringing & dismantling of existing 220KV Jack Bus Bar (Approx. length 75 Meter) of single ACSR Moose conductor of 220KV Bay of existing 315MVA Transformer - IV including De-hoisting of Disc Insulator strings of Tension & fittings from gantry alongwith shifting of the old conductors and fittings etc. from switchyard to sub station stores. (1 Job. for each Bays of each section of the Bus Bar). 59 Stringing & proper sagging of 220KV Jack Bus Bar section (R, Y & B phase) for 500 MVA, 400/220/33 KV Transformer by twin Moose conductor, the work includes carriage of conductor from store to site, straightening, cutting & bending fitting of hardware, spacers etc. alongwith hoisting of 120 KV disc insulator string etc. with all cost of men and T&P required for the job. Approx. length 75 Meter (R, Y & B phase) 60 Bay wise interconnection of equipment with twin moose conductor of R, Y & B phase at 220 KV Bus Bar to standard Isolator of Bus - I ( 1E/S), Tandem Isolator of Bus- II, Line Isolator (2E/S) and Tandem Isolator of Transfer Bus including cutting, bending to proper shape, size fixing with clamp and all associated works as per specification. 61 Breakdown Voltage Test, Water Content Test, Dielectric Dissipation Factor Test, Resistivity and Dissolved Gas Analysis (as per IS Norms) along with collection charges of 1 No. Oil Samples (1st Oil Sample for testing will be taken before charging) of new 500MVA, 400/220KV Transformer. Dissolved Gas Analysis (as per IS Norms) along with collection charges of 3 No. Oil Samples (2nd Oil Sample for testing will be taken after 24 hrs. of charging) of new 500MVA, 400/220KV Transformer, 3rd Oil Sample for testing will be taken after 7 days of charging and 4th Oil Sample for testing will be taken after 1 month of charging. 62 Providing Electrical Safety clearance from Office of the Director Electrical Safety, Gomti Nagar, Lucknow by submitting Electrical inspection fees through Challan for Energisation of 1 no. 500MVA, 400/220KV Transformer.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
48.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
49.
Public Administrative Department #10386948 Price Bid
Tender For Annual Operation And Maintenance Of Existing Infrastructure Comprising Of Electromechanical Equipments Internal External Electrical System In Jksidco Managed Industrial Complexes Of Jammu Division-- 1 Complete rewinding of following submersible Motors including rebate of old material. 2 5 HP Capacity 3 7.5 HP Capacity 4 10 HP Capacity 5 12.5HP Capacity 6 15 HP Capacity 7 17.5 HP Capacity 8 20 HP Capacity 9 22.5 HP Capacity 10 25 HP Capacity 11 Complete rewinding of horizontal Squirrel Cage Motors High Speedtype including rebate of old material 12 5 HP Capacity 13 7.5 HP Capacity 14 10 HP Capacity 15 Repair to 5/7.5HP/10HP capacity motor by way of replacement of bearing at DE and NDE and assembling of motor. 16 Repair to 5/7.5HP/10HP capacity motor by way of welding, turning, polishingof shaft , sleeve to end covers and assembling of motor etc. 17 Disconnecting the electrical connection, disengaging the pump motor set from base frame , making alignment, all electrical connection and testing therof. 18 Loading of motor pump set into mechanical transport and carriage to workshop and unloading thereof. Loading the motor pump set into mechanical transport and carriage to site and unloading thereof by using skilled/unskilled labour and other tools and tackles 19 Up to 10 Km 20 Above 10Km upto 15Km 21 Loading of damaged Submersible Motor (V4) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 22 Loading of damaged Submersible Motor (V6) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 23 Submersible Pump V4 to V8 24 Disconnecting of power supply and testingof pump at site 25 Dismantling of submersible pump set at workshop and checking for its replacement of damaged parts. 26 Providing and fitting of new pump shaft 27 Reconditioning of pump shaft by way of welding, turning and polishing to actual size, making of key way 28 Providing and fitting of new cast iron impeller. 29 Reconditioning of impeller by way of welding, turning and polishing to the actual size. 30 Providing and fitting of new Neck Ring. 31 Providing and fitting of Shaft Sleeve. 32 Providing and fitting of Coupling with key 33 Providing and fitting of Bowl Bush 34 Providing and fitting of NRV Bowl. 35 Providing and fitting of Tee Bolts/per piece 36 Providing and fitting of Stud fasting ring with studs upper and lower and circlip lock. 37 Providing and fitting of Diffuser. 38 Providing and fitting of thrust bearing / thrust pad set 39 Assembling of Pump and then coupling with motor with proper alignment. Testing in test pit at workshop. 40 Providing and fitting of copper submersible cable 3 core along with thimbles 41 2.5 Sqmm 42 4Sqmm 43 6Sqmm 44 10Sqmm 45 16Sqmm 46 Extraction out of Submersible Motor pump set 47 Extraction out2.5 inch dia to 4 inch dia column pipes from tube by way of Disconnecting of Power connections from starter panel, disengaging from delivery bend and extracting out Submersible Pump Set complete along with column pipes by hoisting chain pulley block at Tube well, stacking of column pipes and Submersible cable properly. 48 Column pipes 0 to 10 Nos 49 Column pipes 10 to 20 Nos 50 Loweringof Submersible Motor pump set 51 Lowering of2.5 inch dia to 4 inch dia column pipes in Tube well byMaking of cable connection of motor with Submersible cable after dressing cable ends properly. Making of each joint water proof. Lowering of Submersible Pump Set complete along with column pipes and submersible cable with providing & fitting of jointing material and nuts and bolts. Making of connections to the starter panel 52 Column pipes 0 to 10 Nos 53 Column pipes 10 to 20 Nos 54 Star Delta control panels for Submersible pump set 55 Disconnection ofincomingPowerconnectionfrommainswitch /MCCB/Voltage Stabilizer and checking of fault. Making of temporary arrangement for running of pumpingmachinery 56 Providing and fittingof Damaged Contactor of following ratings 57 MNX 25 Amp 58 MNX 45 Amp 59 MNX 50 Amp 60 MNX 70 Amp 61 MNX 95 Amp 62 MNX 110 Amp 63 Providing and fittingof Damaged Kit of following rating contactors 64 MNX 25 Amp. 65 MNX 45 Amp. 66 MNX 50 Amp. 67 MNX 70 Amp. 68 MNX 95 Amp. 69 MNX 110 Amp. 70 Providing and fittingof Damaged coil of following rating contactors 71 MNX 25 Amp. 72 MNX 45 Amp. 73 MNX 50 Amp. 74 MNX 70 Amp. 75 MNX 95 Amp. 76 MNX 110 Amp. 77 Providing & Fitting of Auxiliary block 78 Providing & Fitting of Aluminum Bus Bar 79 Providing & Fitting of damaged over load relay & P/F new overload Relay 80 Providing & Fitting of damagedundervolt relay&P/Fnew relay 81 Providing & Fitting of single phase preventer ( L&T) 82 Providing & Fittingof DamagedMCCB 83 63 Amp 4pole 16KA 84 100 Amp 4pole 16KA 85 160Amp 4pole 16KA 86 200 Amp 4pole 36KA 87 250 Amp 4pole 36KA 88 400 Amp 4pole 50KA 89 630 Amp 4pole 50KA 90 Making of incomingPowerconnectiontomainswitch/MCCB/Servo Stabilizer and checking on full load at site 91 Control Star delta panel up 15 to 100 Amp. 92 Chargesforminorrepair/servicingofLTControlPanel including minorparts like meters, indicators , timers etc 93 Providing /fitting of circuit wiring 94 Providing /fitting of voltmeter Analog 95 Providing /fitting of amp meter Analog 96 Providing /fitting of Amp selector switch 97 Providing/ Fitting ofdigital Volt meter 98 Providing / Fitting of digital Amper meterCT operated 99 Providing /fitting of volt selector switch 100 Providing /fitting of Push Button on/off 101 Providing /fitting of indicator lamps R/4/B 102 Providing /fitting of star delta timer 103 Providing /fitting of terminal plate 104 Providing /fitting of quartz timer 105 Providing /fitting of delay timerProviding /fitting of delay timer 106 Providing /fitting of power wiring 107 Providing /fitting of thermal overload relay 108 Providing /fitting of bus bar 109 Providing /fitting of fuse link 110 Providing /fitting of fuse holder suitable for bolted fuse link 111 Servo Stabilizer 25 to 50 KVA Capacity 112 Rewinding of copper Coil & fitting etc at site. 113 Providing & Fitting of Dimmer coil 60Amp. 114 Providing & Fitting of Change Over Switch 100 ampere 115 Providing & Fitting of Change Over Switch 100 ampere 116 Providing & Fitting of digital Control card 117 Providing & Fitting of carbon brushes 118 Providing & Fitting of moving arm 119 Providing & Fitting of RC circuit 120 Providing & Fitting of toggle switch for auto /manual 121 Providing & Fitting of CT 100/5A 122 Providing & Fitting of limit switch 123 Providing & Fitting of gear wheel 124 Providing & Fitting of Indicator 125 Providing & Fitting of Selector Switch 126 Providing & Fitting of Ampere meter 127 Providing & Fitting of Voltmeter 128 Fresh Transformer Oil per litre 129 Providing & Fitting of Nut Bolts 130 Complete power wiringwith thimbling 131 Complete top panel wiringwith thimbling 132 Disconnecting of power connection of the servo Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour. 133 Distribution Transformers 134 63KVA Capacity Transformer 135 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 136 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 137 Reconditioning of LV Aluminium coilper kg 138 Providing and fitting of HV leg coil Aluminium SE (per Kg) 139 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 140 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 141 Providing & fitting of HV bushing 142 Providing& fitting of LV bushing 143 Providing& fitting of HV bush rod (metal part)per rod 144 Providing& fitting of LV bush rod (metal part) per rod 145 Providing& fitting of gasket set 146 Providing& fitting of tapping switch with handle 147 Providing & fitting of LT terminal plate 148 Providing & fitting of Oil drain valve 149 Providing & fitting of core laminations per Kg 150 Providing& fitting of sundry items 151 Heat treatment of repaired transformer 152 Arresting of oil leakages if any by way of welding etc. 153 Painting of transformer body 154 Silica Gel breather 155 Providing & Fitting of fresh T-oil 156 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 157 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 158 100KVA Capacity Transformer 159 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 160 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 161 Reconditioning of LV Aluminum coilper kg 162 Providing and fitting of HV leg coil Aluminium SE (per Kg) 163 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 164 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 165 Providing & fitting of HV bushing 166 Providing& fitting of LV bushing 167 Providing& fitting of HV bush rod (metal part)per rod 168 Providing& fitting of LV bush rod (metal part) per rod 169 Providing& fitting of gasket set 170 Providing& fitting of tapping switch with handle 171 Providing & fitting of LT terminal plate 172 Providing & fitting of Oil drain valve 173 Providing & fitting of core laminations per Kg 174 Providing& fitting of sundry items 175 Heat treatment of repaired transformer 176 Arresting of oil leakages if any by way of welding etc. 177 Painting of transformer body 178 Silica Gel breather 179 Providing & Fitting of fresh T-oil 180 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 181 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 182 250KVA Capacity Transformer 183 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 184 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 185 Reconditioning of LV Aluminum coilper kg 186 Providing and fitting of HV leg coil Aluminium SE (per Kg) 187 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 188 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 189 Providing & fitting of HV bushing 190 Providing& fitting of LV bushing 191 Providing& fitting of HV bush rod (metal part)per rod 192 Providing& fitting of LV bush rod (metal part) per rod 193 Providing& fitting of gasket set 194 Providing& fitting of tapping switch with handle 195 Providing & fitting of LT terminal plate 196 Providing & fitting of Oil drain valve 197 Providing & fitting of core laminations per Kg 198 Providing& fitting of sundry items 199 Heat treatment of repaired transformer 200 Arresting of oil leakages if any by way of welding etc. 201 Painting of transformer body 202 Silica Gel breather 203 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 204 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 205 Making of LT side cable connections as well as HT side cable connections and charging the transformer on no load conditions and thereafter checking on full load conditions. 206 Providing and filling of transformer oil for topping (per litre) 207 Providing & fitting of Lighting arrestor station type 208 Providing & fitting of Lighting disc insulator with accessory polymer type 209 Providing & fitting of Lighting pininsulator with pin polymer type 210 Providing & fitting of Lighting AB switch 400Amp with handle operated. 211 Providing & fitting of Lighting AB switch 200Amp with handle operated. 212 Providing & fitting of horn gap DO switch 213 Providing & fitting of Prodigy meter 214 Providing & fitting of chemical earthing 215 Providing & Fixing of Aluminum unarmored cable 1x120 Sq.mm 216 Providing & Fixing of Aluminum narmoured cable 1x185 Sq.mm 217 Road lighting network 218 Providing & fitting with LED fitting 60/65 Watt along with allied Nipple for fixing of LED Fitting with wiremesh protection etc. 219 Providing and fitting of MCB/ SPN installed for controlling of Road lighting Network of following 220 SPN 32Amp 221 TPN MCB 32Amp. 222 Supply and fixing of dust and weather proof gasketted 250mm x 250mm x 200 mm deep cable looping box (nominal) size made out of 18 SWG fitted with pole with the help of 2 Nos. MS clamp (25x3mm) thick flat strip of suitable size with nuts and bolts. Complete with hinged cover locking L-Key/Nut Bolts type, earth studs suitable for poles mounted including supply and fixing of 6A MCB SP, MCB carrier and 4-way 63A terminal block fixed on suitable size and suitable for receiving PVC armoured cable complete with connections and painting etc. 223 Providing and fittingof connection strip 63Amp 4pole heavy duty 224 Providing & Fixing of prodigy meter 225 Providing and fitting of SP MCB 6Amp. in existing connection box 226 Repairingof existing 150/160 Watt LED light 227 Providing and fitting of connection wire 2x1.5 sq mm in steel tubular pole. 228 Fabrication, Supplying and fixing of 40mm dia MS pipe (Medium Class) bracket for mounting LED Street light fitting on pole at appropriate place including bending to required shape at 105 degree, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting to clamps with primer and finish paint etc as required complete Job. 229 Providing and fitting of contractor MNX 9Amp. For timer 230 Providing and fitting Solar/Quartz timer 231 Cables of following sizes 232 Providing & laying of Aluminum armored in ground 2.5feet below the ground level along with HDPC pipe 40mm Dia of Following sizes:- 233 2x10 Sq.mm 234 4x10Sqmm 235 4x16Sqmm 236 4x25 Sqmm 237 4x35 Sqmm 238 3.5x50Sqmm 239 Internal Electrification 240 Providing & fixing fall ceiling light 6/7 watt 241 Providing & fixing fall ceiling light 9/10 watt 242 Providing & fixing fall ceiling light 12 watt 243 Providing & fixing LED tube light complete fitting 20 watt 244 Providing & fixing LED bulb 9 watt 245 Providing & fixingmodular switch 5/6Amp 246 Providing & fixingmodular switch 15/16Amp 247 Providing & fixingmodular socket 5/6Amp 248 Providing & fixing modular socket 15/16Amp 249 Providing & fixingmodular bell push 250 Providing & fixingFan dimmer 251 Providing & fixing modular plate 2 module 252 Providing & fixing modular plate 3 module 253 Providing & fixingmodular plate4module 254 Providing & fixingmodular plate 6 module 255 Providing & fixingmodular plate 12 module 256 Providing & fixingSPN 32 amp in existing DB 257 Providing & fixingSP 6 to 32 amp in existing DB 258 Providing & fixingTPN 32 amp in existing DB 259 Providing & fixingmodular plate 6 module 260 Providing & fixingof following size single core copper wire in existing conduit. 261 1x1.5 sqmm 262 1x2.5 sqmm 263 1x4 sqmm 264 1x6 sqmm 265 Providing & fixingCeiling fan 1200mmbase model 266 Providing & fixingexhaust fan 300mm 267 Providing & fixingInverter 1000VA 268 Providing & fixingInverter 2000VA 269 Invertor Battery 160 AH 270 Servicing of window/spilt AC 271 Water distribution system 272 Providing & laying of GI pipe, complete with fitting in ground including trench & refilling the same. 273 40mm Dia 274 50mm Dia 275 65mm Dia 276 80mm Dia 277 100mm Dia 278 Providing & laying of GI Elbow of following sizes:- 279 40mm Dia 280 50mm Dia 281 65mm Dia 282 80mm Dia 283 Providing & laying of GI Socket of following sizes:- 284 40mm Dia 285 50mm Dia 286 65mm Dia 287 100mm Dia 288 Providing & fixing of MS flange of following sizes:- 289 2 inch 290 2.5 inch 291 3 inch 292 4 inch 293 5 inch 294 Providing & fixing Sluice Valvecast Iron (Heavy Duty) 295 50mmǾ 296 65mmǾ 297 80mmǾ 298 100mmǾ 299 125mmǾ 300 150mmǾ 301 Providing & fixing NRV cast Iron (Heavy Duty) 302 50mmǾ 303 65mmǾ 304 80mmǾ 305 100mmǾ 306 125mmǾ 307 150mmǾ 308 Repairing of cast Iron valve with finishing and polishing 309 50mmǾ 310 65mmǾ 311 80mmǾ 312 100mmǾ 313 125mmǾ 314 150mmǾ 315 Jointing of MS/GI pipe 50mmdia to make leak proof 316 50mmǾ 317 65mmǾ 318 80mmǾ 319 100mmǾ 320 125mmǾ 321 150mmǾ 322 Providing and fittingof short bend of following sizes 323 80mmǾ 324 100mm 325 150mm 326 Providing and fittingof Long bend of following sizes 327 80mm 328 100mm 329 150mm 330 Providing and fittingPuncher Roll to make leak proof connection 331 Adhesive Tape
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
50.
Public Administrative Department #10348518 Price Bid
Tender For Maintenance Of Rajkot Circle Office Building Rajkot For Year 2025-26; 1 Execution of work under following items 2 Laying & fixing of conduit, cutting, glueing/jointing, fixing saddles/spacers, making good wall/ceiling penetrations, testing continuity and final inspection — per meter (includes testing) as per instruction of engineer in-charge. (complete SITC) 3 Removing dry/oil bound distemper and waterproof paint by scrapping, sand papering & preparing surface smooth (Interior walls – long & partition walls). 4 Supply of PVC conduit pipes (ISI marked, BEC / AKG / Precision / Pressfit / Steel Craft) and fittings (elbows, couplers, bends, boxes) — per meter. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. (complete SITC) 5 Applying one coat of ready-mixed red-oxide zinc chromate primer on steel/galvanized iron work (surface prep by wire-brushing included). 6 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead (for 10–25 mm thick tiles) 7 Removal of existing tiles and excavation of protruding tree roots, filling void with compacted sand/aggregate and repairing base with cement mortar. 8 Exterior painting for boundary wall with synthetic enamel paint of approved brand to give even shade. 9 Consumables & minor items per point: screws, PVC clips, tapes, cable ties, sealing compounds, short patch cords, final cleaning 10 Silver painting over existing partitions (aluminium paint) to give even shade. 11 Spray painting over existing almirahs (steel work) with deluxe multi-surface paint; two coats @ 0.9 L/10 sqm over undercoat of primer @ 0.8 L/10 sqm. 12 Waterproof cement paint above dado (2.1 m to 2.5 m height) + Acrylic emulsion on ceiling incl. edges 13 Interior walls finishing with deluxe multi-surface waterproof paint system using primer as per manufacturer’s specification (two or more coats). 14 Finishing walls with water proof cement paint (two coats) of approved brand and shade. 15 Finishing with epoxy paint (two or more coats) on steel work (over primer) for window grills and MS gates, including surface prep and scaffolding. 16 Supply, Fixing & wiring: mounting plate, connection to point wiring, ferruling, testing & cleaning (per unit) (Labour and testing included) 17 Providing and fixing CPVC distribution pipe (20/25 mm dia) for outlet and internal distribution: Supply and fix CPVC pipe with fittings (tees, elbows, bends, reducers, clamps) from rooftop tanks to toilet blocks, wash basins & taps; include wall drilling, sealing, testing, flushing, and making good disturbed surfaces with cement mortar; pressure tested to 10 kg/cm². Material should be of approved brand by engineer in-charge. 18 P&F CPVC pipe 20/25 mm dia (supply) — ISI/approved CPVC pipe, per meter supply -inclusive of all fittings such as elbows, tees, unions, couplers, sockets, angle valves, stop valves, bib taps, outlet taps (chrome plated), pipe support and all fittings complete 19 Applying 12 mm cement plaster (single coat) on both faces of partition up to 3.5 m height, including hacking/keys where required, on walls, partition walls etc as per direction of engineer in-charge 20 Supply and fixing Coat / robe hooks (SS) — 2 nos. 21 Supply and fixing of switches & sockets (Anchor Roma / Legrand Myrius / Schneider Livia / GM / Havells Crabtree), with modular plates and mounting boxes. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 22 Installation: Conduit routing, pulling & laying of wires, fixing boxes, switch & socket fixing, terminations, ferruling, earthing connection at point; including testing & commissioning of points (insulation/continuity) 23 Supply and fixing of Coat hooks / robe hooks (stainless) — supply & fixing of 2-hook stainless robe/coat hook set. - Two hooks per door/near entrance; SS finish; fixing with screws & plugs. 24 Supply and fixing of CPVC pipe 32 mm dia (supply) — ISI/approved CPVC pipe, per meter supply - inclusive of all fittings such as elbows, tees, unions, couplers, sockets, angle valves, stop valves, bib taps, outlet taps (chrome plated), pipe support and all fittings complete 25 Providing and fixing CPVC supply pipe (32 mm dia) for inlet lines: Concealed / open fixing on walls, floors or ceilings with CPVC fittings (elbows, tees, unions, reducers, bends, clamps, supports @1.5 m intervals), testing for leakage at 10 kg/cm² and flushing complete. Lines connect UG tank → booster pump → 500 L & 2000 L tanks and other locations as required. Material should be of approved brand by engineer in-charge. 26 Main circuit connection from DB to sub-circuit — Supplying and laying 3-core × 2.5 sq.mm FRLS copper wire in 25 mm PVC heavy-duty conduit (ISI-marked), with saddles and fittings, from main DB to lighting/exhaust/hand dryer circuit - inlcusive of Earthing & continuity connection — Providing 2-core × 2.5 sq.mm green FRLS copper wire from DB to all metallic fixtures (fans, lights, hand dryer), complete with earthing links, screws, and testing for continuity as per IS:3043. 27 Polymer-modified cementitious waterproof coating over floor and 300 mm skirting as per direction of engineer in-charge 28 Repair of loose plaster, cracks, and honeycombs: Raking out weak mortar and repairing surface defects with cement mortar 1:3 (1 cement : 3 coarse sand); applying bonding coat and finishing smooth; curing for minimum 48 hours. (including arrangement for water) 29 Repairs to plaster 12–20 mm thick in patches under 2.5 sqm using 1:4 mortar, cutting, raking joints and finishing smooth. 30 Suction & Delivery GI/HDPE Pipe with Fittings (50 mm dia): Supply, cutting, threading, jointing, laying and supporting suction (≈10 m) & delivery (≈15 m) pipes from UG tank to rising main including bends, elbows, reducers, flanges, painting with red oxide primer and two coats enamel. Material should be of approved brand by engineer in-charge. 31 Fixing, connection to point wiring, testing, commissioning, leveling and final cleaning per unit (complete installation and testing as per instruction of engineer in-charge) 32 Towel rail / ring (stainless steel) — supply & fixing of SS towel rail / ring (chrome finish), heavy duty brackets and plugs. - SS 304 finish; mounting on tile with rubber grommet. 33 Supply of materials for point wiring — FRLS PVC insulated copper wire (Finolex / Polycab / RR Kabel / Havells / KEI), rigid PVC conduit & accessories (BEC / AKG / Precision / Pressfit), modular switch plates (Anchor / Schneider / Legrand / GM). Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 34 Fixing, point wiring, balancing, testing & commissioning per fan (Installation & commissioning included) 35 SS dustbin (pedal / lid) — supply & fixing — stainless steel (SS 304), 12–15 L capacity, wall bracket or floor standing. - One dustbin per cluster; provide anti-corrosion polish & mounting. 36 Construction of Brick wall of 230 mm thick — providing & laying F.P.S. bricks in cement mortar up to 3.5 m height, as per directions of engineer in-charge 37 Glazed ceramic wall tiles up to 2.1 m height — supply & fixing in 1:4 cement mortar, pointing as per direction of engineer in-charge 38 Anti-skid ceramic floor tiles 300×300 mm — supply & fixing in 20 mm CM 1:4, jointing & grouting; . - (Tiles as per approved makes (Kajaria / Somany / Nitco / Johnson / Asian or equivalent as approved by engineer-incharge). Adhesive, joints & cutting included. 39 Point wiring for lighting/exhaust/hand dryer (6 points) — PVC conduit, FRLS Cu wire, modular switches, ceiling rose, termination, testing. 40 False ceiling — suspended grid (GI channels / hangers) with 595×595 mm PVC ceiling panels or equivalent PVC/GI panels, complete with edge trims and cut-outs for fixtures. For area ≈ 5.0 m². Approved makes: Armstrong / Gyproc / USG Boral (ceiling systems) or approved PVC panel. - Includes hangers, wires, screws, grilles & fixing; drop ~300 mm. 41 Relaying new tiles using 40% old tiles — double charge vitrified polished finish (600×600 mm). 42 Glass replacement in windows with 5 mm float glass panes, including removal of damaged panes, cleaning rebates, fixing with putty/clips and finishing. 43 Supply and fixing of LED fixtures (36W) (Philips / Wipro / Havells / Bajaj / Crompton) including drivers, mounting brackets and wiring accessories — per unit. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 44 Silicone sealant, making good & final cleaning (LS) — sealant at all junctions, touch-up paint, final cleaning & disinfection prior to handover. - Includes consumables and labour for final handover. 45 Disposal of silt, debris, and foreign matter: Collection, loading, and removal of all dirt, silt, sludge, and waste materials from tank and surroundings within 50 m lead as directed by Engineer-in-Charge. (includes loading/unloading labour, and tools) 46 Final washing, drying, and refilling for test: Rinsing with clean water twice, drying for 6 hours, and refilling tank partially to check for leakage or seepage. (include water and labour) 47 SS dustbin (small) + grab rail / grab bar (stainless steel) supply & fixing (accessibility requirement). - SS 304 48 Soap dispenser (wall mounted, stainless / ABS pump) — supply & fixing, refillable type, anti-vandal. - Installed at basin height; includes adhesive & screws, sealing. 49 Disinfection using bleaching powder solution: Preparing and applying fresh solution (0.5 g/litre concentration) of bleaching powder (30% available chlorine); brushing and spraying entire surface uniformly as per instuction of engineer in-charge 50 Pressure Gauge Assembly & Accessories: Bourdon-type 0–10 kg/cm² with isolation valve mounted on delivery line, including brass fittings, air-release valve (15 mm), reducers and testing. The material should be IS:3624 compliant. 51 Supply of 1200 mm ceiling fan (Bajaj / Usha / Crompton / Havells / Orient) with accessories (downrod upto 3 m length wherever required, canopy, capacitor) — per fan - Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 52 Pumping out stagnated water and sludge removal: Dewatering the underground tank (approx. 5m × 3m × 2.5m) using 3–5 HP portable submersible pump; bailing out accumulated water, sludge, and silt; manual scooping of residues and transferring to containers for safe disposal within 50 m. (Includes dewatering pump operation and labour.) 53 Installation: wiring from distribution, fixing isolator & point, earthing, testing & commissioning per AC point (includes switchgear mounting) (final testing to be done) 54 Mirror (600×450 mm) supply & fixing — bevelled or framed as approved. - Mirror fixed to wall with concealed hangers & silicone seal. 55 Soap dispenser + towel ring + toilet roll holder — supply & fixing; chrome plated brass/ABS as approved. - Includes adhesives, screws & wall plugs. 56 Grab rails / handrail & signage / coat hook — additional small fittings & SS hardware. 57 aluminium ventilators — 3 no. powder-coated aluminium louvre ventilators (400×400 mm) with insect mesh; including frames, SS hinges, locksets & sealing. 58 Electrical wiring & lighting installation — Supply, installation and wiring of 6 nos. light / exhaust / switch points including modular switches, MCB protection, PVC concealed conduit (20 mm), copper FRLS wire (1.5 sq.mm), ceiling rose, junction box, and accessories. 59 LED light fittings — Supply & fixing of 3 nos. LED ceiling lights 18 W, surface / recess mounted type, with necessary wiring and testing. Approved makes: Havells / Crompton / Philips / Bajaj / Wipro. includes fixing accessories, ceiling cutting, and finishing. 60 Commissioning verification (included within installation): continuity, polarity, insulation tests; corrective adjustments and handing over (per DB) 61 Granite counter for basins (3 nos) — supply & fixing of granite top (approx. 1.8 m length × 0.5 m width total area ≈0.9 m²) with cutouts for 3 basins, edge polishing, pedestal support & fixing. 62 Scaffolding, lighting, safety & PPE for confined space: Providing ladder, safety harness, safety rope, blower fan for ventilation, hand gloves, boots, masks, and site supervision for labour working inside tank. 63 Exhaust fan installation — Supply, fixing and connection of 2 nos. 200 mm dia exhaust fans with louvre and PVC frame, including 1.5 sq.mm wire, 2-pole MCB, and mounting. Approved makes: Crompton / Havells / Bajaj / Almonard / Usha. Includes making opening in wall / false ceiling and making good. 64 Installation: excavation for earthing pit, supply & compaction of back-fill, connection to main earthing conductor, testing (earth resistance), backfilling & reinstatement ( includes labour, testing & reinstatement) 65 Supply of isolator, modular accessories, switches, enclosure/housing & associated materials per AC point (all standard materials required per AC power point and as per instructions of engineer in-charge) - Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 66 Tools, consumables: Supply and use of wire brushes, buckets, cleaning agents, safety gear, and minor hand tools. 67 Cold water supply distribution — Supply & fixing CPVC pipes (32/25 mm main + 20 mm branches), fittings, tees, unions, clamps & supports up to fixtures; includes angle valves (brass) and bib taps. Approved makes: Astral / Finolex / Supreme / Havmor (pipes & fittings), Jaquar / Cera (valves). - Includes joints, supports, wall chases & making good. Pressure test to 10 kg/cm². 68 Providing and fixing factory-made solid-core PVC doors suitable for toilet applications, comprising 30 mm thick PVC shutters made from multi-chambered extruded rigid PVC sections with integral stiles and rails, filled with solid PVC core, termite-proof, moisture-resistant, and fire-retardant, including smooth matt/semi-gloss finish in approved shade. The door frame shall be of PVC hollow sections 50×47×2 mm, mitre-jointed and solvent-welded, fixed in position with stainless steel screws, fasteners, and polymer sealant. Shutters shall be hung on three stainless steel (SS 304) hinges, fitted with SS mortice lock with two keys, tower bolt, rubber gasket/edge seal, door stopper, and necessary hardware. All joints shall be solvent welded, sealed watertight, and finished smooth. Size - 0.75 m × 2.00 m (clear opening) with outward swing and 20 mm bottom clearance from finished floor level. 69 Ventilation & lighting — Supply & fixing of 1 no. exhaust fan (200–250 mm), 1 no. LED ceiling light (18 W), wiring from nearest DB up to 5 m including modular switch & connection. Approved makes: Crompton / Havells / Philips / Bajaj or equivalent make. - Includes mounting, short conduit & testing. 70 Providing & fixing glazed wooden doors / shutters (30 mm thick wood) with 4 mm float glass panes, ISI MS pressed butt hinges & fittings, polished finish. 71 Provision & fixing of factory-made PVC door (30 mm thick solid-core) — supply, frame, SS hinges (3 nos.), mortice lockset with 2 keys, tower bolt, rubber gasket/seal, setting & making good. Standard size assumed 900×2100 mm. 72 Urinal partitions — supply & fixing (granite / high-density PVC panel) — panel size each 0.60 m × 1.20 m = 0.72 sqm; supply, template cutting, SS clamp supports, edge polishing, grout/sealant, and fixing in masonry opening. Qty = 5 nos (total 3.6 sqm). Approved: granite local / Bharat / Johnson or PVC from approved make. 73 Cleaning internal surfaces with wire and coconut brushes: thorough scrubbing and cleaning of walls, ceiling, and floor surfaces to remove algae, scales, and microbial growth; washing with clean water under pressure; collecting and removing sludge. (Complete surface cleaning up to 4–5 m tank depth). 74 Valves & Fittings Set: Includes 1 no. 50 mm NRV, 2 nos. 50 mm gate valves, 1 no. 50 mm foot valve with strainer, and all gaskets, nuts, bolts & washers; installation and testing complete as per IS:778 & IS:13095. 75 Main Entry Door (PVC solid core, 30 mm thick) with SS hinges, lockset, tower bolt, rubber seal, aluminium threshold – size 1.0×2.1 m complete with frame of approved brand and direction of engineer in-charge. - All doors shall be installed true to plumb, tested for smooth operation, and properly sealed to prevent ingress of moisture. Approved makes: Syntex / Wintech / Greenply / Rajshri or equivalent as approved by Engineer-in-Charge. 76 Supply of earthing materials per set: opper plate 600×600×3 mm (IS 3043) / Copper strip 25×3 mm (Havells / Ravin / CCI / Polycab / JEF), GI pipe for electrode, salt/charcoal back-fill, GI clamp, copper conductor to DB etc. (all materials required for earthing set complete and brand as approved by Engineer in-charge) 77 CP fittings, valves & accessories — bib cocks, angle valves, bottle traps, stop cocks, etc. (supply & fixing, leak test). 78 Supply, installation & connection of PVC Water Storage Tank (500 L): ISI-marked rotational moulded tank (Sintex/Plasto or approved), cylindrical vertical type with closed top; inlet, outlet, overflow & drain arrangements with ball valve; mounted on steel/concrete pedestal; connected to SA’s chamber toilet via 25 mm CPVC pipe; testing & disinfection complete. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 79 Minor Civil & Finishing Works: Includes repairing of disturbed plaster, floor making, cutting & sealing pipe openings, applying waterproof sealant at pipe entries, touch-up paint and cleanup of site along with Testing, Commissioning & Trial Run: Includes hydraulic testing of suction and delivery line, electrical testing for insulation resistance, earthing continuity, 48-hour trial run with load, demonstration to departmental staff, and submission of test report and warranty documents (minimum 1-year) 80 Foundation & Base Plate: MS base frame (10 mm thick) with foundation bolts and vibration pads, anchored on RCC pedestal (1.2 m × 0.6 m × 0.3 m), including painting and finishing around base. 81 Installation of DBs: Mounting on wall/stand, internal connections, earthing, MCB ferruling, interconnection to main incomer cable and proper labeling; testing for tightness and operation, labeling and dressing (including functional checks) 82 Sub-MCB protection & labeling — Supply, fixing & wiring of 6-way SPN MCB box (sheet steel, IP-65, powder-coated) with 32A incomer MCB and 6 outgoing circuits (6A–10A rating). Includes ferruling, labeling, and load marking. Approved makes: Legrand / Schneider / Siemens / Havells / L&T. (including plaster and paint patch work repair) 83 Sub-DB / MCB box & final connection — 6-way SPN with 32A incomer, ferruling, labelling & earthing. 84 Soil & waste discharge and septic tie-in — UPVC/SWR soil pipe 110 mm from pan to septic tank including inspection chamber connection, excavation (small), bedding, socket joints, gradient formation, backfill & making good. (Includes connection to existing septic tank / inspection chamber and leak test.) 85 CP fittings, valves, and accessories – including bib cocks, angle valves, stop cocks, health faucets, bottle traps, wall flange, and all required brass fittings. Approved makes: Jaquar / Kohler / Hindware / Parryware. (Complete with fixing, polishing, sealing and leak testing of all joints.) 86 Control Switch & Protection Panel: Wall-mounted IP-55 rated control box with ON/OFF selector, indicator lamps, thermal overload relay, voltmeter, ammeter, digital hour meter, and labeling. Material should be of approved brand by engineer in-charge. 87 Electrical Cabling & Panel Connection: Supply and lay 3-core × 6 sq.mm Cu flexible cable from nearest panel to starter, with MCB (32 A), DOL/Star-Delta starter, glands, lugs & terminations; approx. 15 m. Includes cable, switchgear, and terminations 88 Supply of DB enclosures and components — powder-coated metallic SPN/TPN type (MDS / Legrand / L&T / Schneider / Siemens), with neutral link, earth bar, incoming MCCB/MCB and outgoing MCBs (10 kA, C-curve). Material shall be of approved make as above or equivalent approved by Engineer-in-Charge. 89 Urinals with partitions – 5 nos. (wall hung type, vitreous china, with CP spreader, flush valve, waste pipe, trap and divider partitions in granite or FRP). Approved makes: Parryware / Hindware / Kohler / Jaquar / Cera. (Includes fixing with CP screws, sealant, flushing connections and making good.) 90 Basins with CP single lever mixer & bottle traps — 3 nos (counter / pedestal as required); supply & fixing. 91 Wash basins with CP fittings – 3 nos. (pedestal/half pedestal type with single lever pillar cock, bottle trap, waste coupling, brackets and all accessories). Approved makes: Jaquar / Kohler / Parryware / Hindware / Cera. (Includes water supply and waste connection, proper leveling, testing and polishing of granite counter if applicable.) 92 Providing & fixing MS rungs (20 mm dia) in underground RCC water tank at 300 mm c/c (approx. 9 rungs) and providing RCC manhole cover (M20) 1.2 m² × 100 mm thick with MS frame, hinges, locking arrangement, finishing and all incidental works, testing & curing 93 Hand dryer installation — Supply & fixing of 1 no. automatic hand dryer (1200–1600 W, IP44 rated) complete with wall plug, electrical connection and testing. Approved makes: Dyson / Crompton / Bobrick / Mitsubishi / Havells. (Includes switch plate, MCB, testing & demonstration.) 94 Laying, termination, testing & commissioning of above power cable with necessary accessories, GI saddles, trenching/ducting, tagging & identification, complete. (4 runs × 25 m = 100 Rmt) 95 Supply, installation & connection of PVC Water Storage Tank (2000 L): ISI-marked triple-layer with all fittings (inlet, outlet, overflow, drain cock, valves & supports), plumbing connections to staff toilets, testing and disinfection complete as per manufacturer’s recommendations and Engineer-in-Charge. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 96 Re-fabrication of main gate (raising height from 1.2 m to 2.1 m; width 3.75 m) including welding, repairs, alignment, priming & painting and supply/fixing of necessary fittings, complete (measured as one job). 97 Supply & fixing of sanitary fixtures (EWC dual-flush + WC seat, 1 urinal) — vitreous china, wall/floor mounted as applicable; includes seat, cistern, flush fittings, urinal trap. Approved makes: Parryware / Hindware / Cera / Jaquar / Kohler. - Supply, transport, setting, sealing & testing; warranty documents. 98 Supply of power cables (AL / Cu) (Polycab / KEI / Havells / Finolex / RR Kabel) & accessories (copper/aluminium cable, glands, lugs, saddles) — supply portion includes Supply of 1.1 kV grade 3½-core 25 sq mm aluminium armoured PVC insulated power cable with glands, lugs & saddles, complete. (4 runs × 25 m = 100 Rmt)- Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 99 SITC of Centrifugal Monoblock Pump (4–5 HP, 3-phase): ISI-marked horizontal end-suction type; delivery head 45–55 m; discharge 300–400 LPM; CI body, bronze impeller, SS shaft, mechanical seal, flanged connections. Make: Kirloskar / Crompton / KSB / Texmo / Lubi. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
TenderDetail
Loading tenders