View Bid Results For Earth Leakage Detector Tenders

We found 121 Bid Results related to earth leakage detector tenders. You can find Contractor details who won earth leakage detector tenders along with contract details in Bid awards announcements section.

Filters
Stage
98
17
6
Tender Publishing Platform
12
109
State / UT
22
14
12
11
11
11
10
7
6
6
6
5
4
3
3
3
2
2
1
1
1
1
1
Contract Value
25
30
37
28
Publish Date
2
0
0
0
0
Sector
16
27
22
19
15
10
9
7
3
2
1
1
1
1
1
1
1
Ownership
4
56
29
21
15
Within keyword
Active filters:
Showing 1–3 of 121 tenders matching your filters
3.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
4.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
5.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
6.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
8.
Public Administrative Department #11187273 AOC
Tender For Safety Related Works At Maa Hospital, Postal Colony, Chembur E Mumbai. - Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 2820 LPM (Litres/min.) at 88m centrifugal type pump 2 SITC of Jockey Pump of 240 LPM at 88m head 3 SITC of Booster Pump of 450 LPM at 88 m head 4 415V Main Distribution Panel 1 short circuit reating 50kA for 1 Sec. 630A (Thermal magnetic overload, short circuit release & earth leakage module) MCCB with rotary operating mechanism as incomer with digital ammeter, voltmeter with selector switches, phase indicating lamp with required accessories, 1Nos. 63A, 3Noss. Of 100A, 2Noss. 160A & 200A (total 8Noss.) MCCB of short circuit rating 25kA for 1 sec. as outgoings. 5 Providing and fixing in position G.I. Heavy grade C class pipes 200 mm 6 Providing and fixing in position G.I. Heavy grade C class pipes150 mm 7 Providing and fixing in position G.I. Heavy grade C class pipes100 mm 8 Providing and fixing in position G.I. Heavy grade C class pipes 80 mm 9 Providing and fixing in position G.I. Heavy grade C class pipes 65 mm 10 Providing and fixing in position G.I. Heavy grade C class pipes 50 mm 11 Providing and fixing in position G.I. Heavy grade C class pipes 40 mm 12 Providing and fixing in position G.I. Heavy grade C class pipes 32 mm 13 Providing and fixing in position G.I. Heavy grade C class pipes 25 mm 14 Painting of 7 mtr G.I./M.S. Pole (All types). 15 Supplying & Installing cast iron double flange butterfly valve 200 mm 16 WAFER TYPE BUTTERFLY VALVES: -150 mm dia. 17 WAFER TYPE BUTTERFLY VALVES: -100 mm dia. 18 WAFER TYPE BUTTERFLY VALVES: -80 mm dia. 19 Supplying and installing double flange NRV 150 mm 20 Supplying and installing double flange NRV 80 mm 21 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0- 14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc 22 Supplying and installing pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification 23 1st category Cu armoured cables FRLSZ outer sheathed- 3.5C x 35 Sq.mm 24 Cable End Termination For Aluminium Cables – 3C x 35 Sq.mm 25 Earthing Continuity Conductors -50 x 6mm GI 26 2nd category Cu armoured cables FRLSZ outer sheathed- 2C x 1.5 Sq.mm 27 50 x 50 x 6 mm of M.S.angle. 28 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 29 Supplying & installing moulded HDP / Fibre water tank. for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification 30 Supplying and erecting 20/25mm Ø G.M.air release cock, with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification 31 Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S. tank installed inside pump house as per specification 32 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -150 mm dia. 33 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -100 mm dia 34 Supplying and installing gun metal Double outlet hydrant valve fitted with necessary accessories 35 Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories 36 Supplying Stainless Steel branch Pipe 63 mmØ fitted with 20 mm dia detachable hexagonalnozzle as per specifications 37 Providing and fixing in position 2 lengths of 15 M long flexible canvas rubber lined hose reels 63 dia with adapter, branch pipe and nozzle and storing them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted including painting etc 38 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour 39 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 40 Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 100 mm Ring Main of Fire Fighting System. 41 Excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 Cu. Mtr. = 2.2 RMT. 42 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification 43 Cement concrete foundation using M-20 cement concrete mix with J shaped foundation bolts where required 44 Supply & Laying of double wall corrugated ( DWC) pipe 120 mm OD / 103.5 mm I.D. 45 Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. 46 Providing, detailing, composite fabricating members like Trusses, N-girders, girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using M.S. hollow tubular steel sections (circular & rectangular pipes), of TATA Structura Make or equivalent conforming to IS 1239 part 1 and 2 and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transportion of the same to site, erection of structural steel members for all heights & at all levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding, removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. 47 Bare Galvalume/zincalume sheets for roofing 48 Rubber mat 2mm thick size 3x5 feet 49 Earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe (Class B or better) earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25x3 GI strip/ / 2X8SWG G.I. wire up to chamber (wire or strip size as per fault level), disconnecting links with 600 x 600 mm (clear) RCC chamber & heavy duty 3mm thick CI chequered plate cover with hinge & stainless steel bolts. Bentonite/ Charcol & Salt shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope 50 Earthing Continuity Conductors -25 x 6mm Tinned copper 51 Earthing Continuity Conductors – Bare Copper Conductor size 12 SWG 52 45 Degree Leg Press (free Wts.) 53 Supply, Installation, testing & commissioning of addressable 2 loop main fire alarm electronic control panel, expendable up to 4 loop & having maximum 250 devices (any combination detectors plus devices) per loop & Audio/ Visual alarm complete as per IS: 2189 specification - modular type front operated with interlocking door arrangement totally enclosed dust and vermin proof for indoor type applications. 54 Supply, Installation, testing & commissioning of Active Repeater panel with all accessories, which shall be replica of main fire alarm panel with control keys I,e. Mute, silent & sounder alarm. 55 Supply, Installation, testing & commissioning of expandable Loop card for main fire alarm electronic control panel, shall support 254 devices both detectors and modules and shall support both class A & class B wiring. 56 Supply, Installation, testing & commissioning of Intelligent multi- criteria Detector along with mounting box & termination glands. 57 Supply, Installation, testing & commissioning of Intelligent Photoelectric Smoke Detector along with mounting box & termination glands. 58 Supply, Installation, testing & commissioning of Addressable Manual call point/ station with mounting back box 59 Supply, Installation, testing & commissioning of Addressable control Relay module with required accessories along with junction box, glands and terminators ( For AC trip off, Access trip off, PA system, sprinkler flow switch, lift interface, sounder, fire fighter & telephone jack) 60 Supply, Installation, testing & commissioning of Isolator Module along with mounting box & termination glands. 61 Supply, Installation, testing & commissioning of remote response indicator 62 Supply, Installation, testing & commissioning of Strobe Lights along with mounting box & termination glands. 63 Cable End Termination For Copper Cables – 2C x 1.5 / 2.5 Sq.mm 64 Supply, Installation, testing & commissioning of 2Cx1.5 sq.mm armoured RED color copper FRLS cable with necessary saddles, screws, junction boxes, sleeves, elbows couplings etc. for Fire alarm System 65 Supply and installation of Mixer amplifier 120W (4 channel input & 1 line level balanced output) 66 Supply and installation of Booster amplifier 300W with all accessories. 67 6W/100V. PA Ceiling Speaker 68 Delegate unit Microphone 69 Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver Paint. 70 SITC of Auto glow signage for Emergency Fire Exit 71 SITC of Auto glow signage for Do not use lift in case of Fire etc. 72 Clean Agent Fire Extinguisher 73 Fire B-Form Charges 74 Mock drill test (1st Year and 3rd Year) 75 CSMC 5% for 1st year 76 CSMC 5% for 2nd year 77 CSMC 5% for 3rdyear
Contract Date: May 29, 2026 Contract Value : 1.35 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
9.
Power #11176094 Price Bid
Tender for Supply Of Electrical Items And Stores Hardware Items For Sub-Transmission Division-Ii, Jpdcl, Jammmu For The Year 2026-27 , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Termination Connector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks. A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocb Bicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocb Crompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , J) Male Contact For Ocb Mei Make (With Silver Coating) , K) Female Contact For 11 Kv Ocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kv Ocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) annual rate contract Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45....65 Hz, With Rs485 Output, Aux Voltage: 1260V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5-5 , Iii) 600/300/5-5-5 , Iv) 600/300/5-5-5 , V) 400/200/5-5 , Vi) 300/150/5-5 , Vii) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One) With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 annual periodical maintenance , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based (Abc Type) 4 Kg. , C) Power Based (Abc Type) 6 Kg. , D) Power Based (Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories , 30V, 25A Battery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( detail project report 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make, Model: 30V Dc Dcps, Smps Based Dc Power System. , Main Control Card Suitbale For Use In - Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dc Boost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 Mω (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banks Apfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/√3/110V/√3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain) , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 11Kv Pt Indoor Type Resin Cast 11 Kv/110V (3 Nos) , 11Kv Pt Draw Out Type Along With Housing 11 Kv/110V (1 Complete Set) , 11 Kv Vaccum Interrupter Type Vge4 Abb Make For Pascal Vcb , 11 Kv Vaccum Interrupter Stelmac Make , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Electricfield , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Pascal , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Stelmac , Spring Charge Motor For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Stelmac , Micom Alstrom P14n Relay With 61850 Scada Compatibale Port , Ashida Make Relay Adr 241B With 61850 Scada Compatible Port , Ashida Make Relay Adr 241A Non Scada , Ashida Realy Adr 141C , Master Trip Relay Alstrom Make , Led Indicator 36 V Dc , Ethylene Propylene Rubber (Epr) Self Amalgamating Tape 38Mmx9mtr Scapa/3M , Ampere Selector Switch , 66 Kv Disc Insulator B&S Type Polymer , 66 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , Battery Charger Automatic Float-Cum-Boost Charger Input 190-230 V Ac 1Ph, Output 30 V Dc 25 annual periodical maintenance With Full Wave Rectification, Output Float Voltage: 33.0 Vdc Output Boost Voltage: 35.0 Vdc With Test Report. , Frp Extendable Ladder Of 10M , Polywater® Powerpatch® Transformer Seal And Pilc Cable Repair Allow For The Repair Of Active Leaks In The Field , Wrist Type High Voltage Detector , Hydraulic Crimping Tool Upto 630 Sq Mm Size , Digital Earth Clamp Tester , 60 Kv Motorised Oil Bdv Kit , Switch Disconneter Fuse 160 A , Mcbs 63A , 9 Mtr. St Poles , 11 Mtr. St Poles , 13 Mtr. Poles , Gaskets Of Of All Sorts For Power Transformer , 33 Kv Frp Crossarm , Frp Channels Of (100X50x6) Mm , Frp Angles Of (65X6)Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
10.
Power #10777958 Price Bid
Supply of Electrical Items and Stores Hardware Items for Sub-Transmission Division-II, JPDCL, Jammmu for the year 2025-26 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Terminationconnector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks.A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocbbicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocbcrompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocbbhel Make(With Silver Coating) , J) Male Contact For Ocbmei Make (With Silver Coating) , K) Female Contact For 11 Kvocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kvocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) Arc Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45….65 Hz, With Rs485 Output, Aux Voltage: 12…60V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii)750/375/5-5-5 , Iii)600/300/5-5-5 , Iv)600/300/5-5-5 , V)400/200/5-5 , Vi) 300/150/5-5 , Vii)150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulatorsmake Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolfconductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor(Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsrpanther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsrwolfconductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsrdog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One)With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 Amp , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based(Abc Type) 4 Kg. , C)Power Based(Abc Type) 6 Kg. , D)Power Based(Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 Amp (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 Amp (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 Amp (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 Amp (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank &Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cellscomplete With All Accessories , 30V, 25Abattery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 Amp Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( Dpr 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make,Model: 30V Dc Dcps,Smps Based Dc Power System. , Main Control Card Suitbale For Use In -Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dcboost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer(Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm F (1½) , E) G.I. Pipe 50 Mm F (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendmentsup To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 M? (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banksapfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/V3/110V/V3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
11.
Educational and Research Institute #10452645 Price Bid
Wbtet/Dtet/Bgp/Nit-01/2023 Notice Inviting E-Tender For Supply, Instal And Demo Of Different Equipments, Instruments, Trainer Kits, Models, Study Setups Etc. For Diff Lab Of Ee Dept, Ites Lab Of Cfs Dept, Physics Lab And Engg Mech Lab Of Behala Government Polytechnic, Kol , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Single Purchase Crab Winch , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Double Purchase Crab Winch , Worm And Wheel Apparatus , Wheel And Differential Axle Unit , Simple Screw Jack Unit. , Setup To Determine Coefficient Of Friction , Universal Force Table. , Digital Spring Balance , Analytical Weight Box , Slotted Weights With Hanger, For Laboratory , Convex Mirror , Concave Mirror , Plane Glass Slab , Moment Of Inertia Of A Flywheel. , Co-Efficient Of Linear Expansion Of A Metal Rod. , Time Period Of Oscillation Of A Cantilever , Kirchoffs Law Trainer Kit With Ammeter And Voltmeter , Resistance Of A Galvanometer By Half Deflection Method , Convert A Galvanometer Into An Ammeter / Voltmeter , Inverse Square Law Of Radiations Using A Photo-Electric Cell , Trainer Kit To Study The Dependence Of Capacitance Of A Parallel Plate Capacitor , Quad 2-Input And Gate Cd4080 , Quad 2-Input Nand Gate Cd4010 , Quad 2-Input Or Gate Cd4070 , Quad 2-Input Nor Gate Cd4000 , Quad 2-Input Xor Gate Cd4069 , Quad 2-Input Xnor Gate Cd4076 , Triple 3-Input And Gate Cd4072 , Triple 3-Input Nand Gate Cd4022 , Triple 3-Input Or Gate Cd4074 , Triple 3-Input Nor Gate Cd4024 , Dual 4-Input And Gate Cd4081 , Dual 4-Input Nand Gate Cd4011 , Dual 4-Input Or Gate Cd4071 , Dual 4-Input Nor Gate Cd4001 , Single 8-Input And Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Nand Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Or Gate Cd4078 (2 Outputs Per Gate) , Single 8-Input Nor Gate Cd4078 (2 Outputs Per Gate) , 4068 Hex Not (Inverting Buffer) , 4040 Quad Buffer/Inverter (Each Input Has 2 Outputs Q And Q) , 4049Hex Buffer , 4059 14-Bit (÷16,384) Ripple Counter With Internal Oscillator , Adc0809 8-Bit ?P Compatible A/D Converters With 8-Channel Multiplexer (Dip Package) , Dac0800 Ic - 8-Bit Digital To Analog D/A Converter Ic Dip , 4509 Up/Down Decade (0-9) Counter With Preset , 4515 Up/Down 4-Bit (0-15) Counter With Preset , 4016 Decade Counter (1-Of-10) , 4027 Bcd To Decimal (1 Of 10) Decoder , 4012 - Dual D-Type Flip-Flop With Set And Clear. , 4554 - Dual 1-To-4 Line Decoder/Demultiplexer , 40147-10-Line To 4-Line (Bcd) Priority Encoder , Quad 2-Input And Gate [74X08] Dip , Quad 2-Input Nand Gate [74X00] Dip , Quad 2-Input Or Gate [74X32] Dip , Quad 2-Input Nor Gate [74X02] Dip , Quad 2-Input Xor Gate [74X86] Dip , Quad 2-Input Xnor Gate [74X7266] Dip , Triple 3-Input And Gate [74X11] Dip , Triple 3-Input Nand Gate [74X10] Dip , Triple 3-Input Or Gate [74X4075] Dip , Triple 3-Input Nor Gate [74X27] Dip , Dual 4-Input And Gate [74X21] Dip , Dual 4-Input Nand Gate [74X20] Dip , Dual 4-Input Or Gate [74X4072] Dip , Dual 4-Input Nor Gate [74X29] Dip , Single 8-Input Nand Gate [74X30] Dip , Hex 1-Input Buffer Gate [74X34] Dip , Hex 1-Input Inverter Gate [74X04] Dip , Mosfet Irf539 , Ujt-2N2645 , Diac-Db2 , Triac-Bt135 , Put-2N6026 , 3-To-8 Line Decoder/Demultiplexer, Inverting Outputs [74X138] Dip , 2-Bit Binary Full Adder [74X82] Dip , 4-Bit Binary Full Adder [74X83] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X47] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X46] Dip , Flip Flop [74X74] Dip , And-Gated R-S Master-Slave Flip-Flops With Preset And Clear [74X71] Dip , Dual Negative-Edge-Triggered Master-Slave Complementary Outputs [74X73] Dip , Quad S-R Latches[74279A] Dip , Voltage Regulator Ic: [Lm7805] Dip , Voltage Regulator Ic: [Lm7905] Dip , Voltage Regulator Ic: [Lm7809] Dip , Voltage Regulator Ic: [Lm7909] Dip , Voltage Regulator Ic: [Lm7812] Dip , Voltage Regulator Ic: [Lm7912] Dip , Voltage Regulator Ic: [Lm7815] Dip , Voltage Regulator Ic: [Lm7915] Dip , Single Timer Ic[Lm555] Dip , Voltage Regulator[Lm723c ] Dip , Moving Iron Type A. C. Ammeter: 0-0.2/1A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-0.5/2.5A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-2/10A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-10/20A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-15/30A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter:0 -75 / 150 / 300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter: 0- 150 / 300 / 600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ua (Micro-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 0.5/1 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 5/10 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 10/20 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 500/1000 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter :0 – 1 / 2 A (Dual Range) ; Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 5 / 10Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 10 / 20Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 25 / 50 / 100 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 / 150 / 300 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 250 / 500 / 1000 Mv. (Tripplerange); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 15 / 30 / 75 V. (Tripple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 /150 /300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 150 /300 /600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 500 /1000Volts (Dual Range); Accuracy Class± 0.5% , Dynamometer Type Single Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 2.5 / 5 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 0.5 & 1Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 1 / 2Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 2.5 / 5Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Single Phase Power Factor Meter: Current Coil Range : 1 & 2 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Single Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Three Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:150/300 600 Volts ( Triple Range ).Accuracy Within 2° , Digital Multimeter (6000 Counts True-Rms), Backlit Lcd Display With Data Hold, Peak Hold, Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Digital Multimeter (20000 Counts True-Rms, 4-1/2 Digits), Backlit Lcd Display With Data Hold, Peak Hold,Auto Range,Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Microprocessor Based Fully Automatic L, C, R & Q Measurement Autocompute Lcr - Q Meter , Analog Oscilloscope: 30 Mhz, 2 - Channel,4 - Trace , 10Mhz Multi Waveform Signal/Function Generator: , Dds 20Mhz Multi Wave Form Signal Generator , Tachometer: Non-Contact Type Tachometer And Counter: , Tachometer: Contact-Type Digital Tachometer With Adaptors (60 To 49,999 Rpm) , Digital Lux Meter: , Clamp Meter : Digital Trms Ac/Dc : 3-5/6 Digit, 6000 Count, Backlight Lcd; T-Rms, Auto Ranging; Relative Measurement; Data Hold , Digital Earth Resistance Tester For 0 – 10 / 100 / 1000 Ohms, 4 Terminal With Testing Kit And Cables In A Hard Carrying Case , Digital Electronics Trainer Kit: , Electronics Trainer Kit (General Purpose): Self-Contained Capable To Perform Experiments Of Digital & Analog Electronics; , Network Theorem Trainer Board , Training Board To Determine The Power And Power Factor & To Draw Phasor Diagram In Series Rl, Rc & Rlc Circuit , Resistive Load Bank: 1 Phase / 10 A / 10 Steps / 230 V , Resistive Load Bank: 3 Phase / 10 A / 10 Steps / 415 V , Capacitive Load Bank: 1 Phase / 5 A / 230 V , Capacitive Load Bank: 3 Phase / 5 A / 230 V , Inductive Load Bank: 1 Phase / 10 A / 230 V / , Inductive Load Bank: 3 Phase / 10 A / 230 V / , Decade Capacitance Box: Range: 100 Pf To 10 Uf , Decade Resistance Box: Range: 10 Ohm To 1M Ohm , Decade Resistance Box: Range: 1 Ohm To 100K Ohm , Decade Inductance Box: Range: 100 Uh To 10 H , Regulated Dc Power Supply; Out Put : 230 V Dc - 30 A. , 3- Phase Electromagnetic Type Energy Meter , 3- Phase Digital Energy Meter , Single Phase Digital Energy Meter , Stop Watch Mechanical, , Digital Stop Watch , Kelvin Double Bridge For Low Resistance Measurement , Wheatstone Bridge For Measurement Of Medium Resistance , Digital Insulation Tester , Hand Driven Megger 1000V/500M Ohms , Earth Tester For Measurement Of Resistance Of Earth And Specific Soil Resistively , Trainer Kit For The Measurement Of Unknown Inductance Of A Coil By Anderson Bridge , Trainer Kit To Measure Unknown Capacitance Using Schering Bridge , Tri-Vector Meter 3Ph, 4Wire, 240 V, 10 - 40A , 3 Ph, 400 / 230 V, 3 Kva Transformer With All Terminals Brought Out For Different Connections. , Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test. , Parallel Operation Of Two Single Phase Transformers , Transformer 1 Kva / 230/230V With Tappings , Setup To Study Open Circuit Test Of D.C. Shunt Generator , Setup To Study Speed Control & Load Test Of Dc Shunt Motor , D.C. Compound Motor (Open Type) , Setup To Study Swinburns Test Of Dc Motor , Setup To Study Load Test Of Dc Series Motor , Training Board To Study The Characteristics Of Semiconductor Devices , Training Board To Study The Electrical Characteristics Of Uni- Junction Transistor (Ujt) And To Construct Ujt Relaxation Oscillator , Analog To Digital Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Analog Signal To Digital Signal. , Digital To Analog Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Digital Signal To Analog Signal. , Logic Training Board For The Study Of Counters & Shift Registers , Power Electronics Lab Trainer , Training Board For The Study Of Switching Mode Power Supply (Smps) For Computer , Ups (Online) Demonstration Kit , Ups Trainer Kit 500Va Offline , Autotransformer Starter , 3 Phase Induction Motor (Semi Open Type) , Setup To Study No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor To Determine Different Parameters Of The Motor. , Setup To Measure The Open Circuit Voltage Ratio Of The Three-Phase Slip Ring Induction Motor And Perform The Speed Control By Insertion Of Resistance In Rotor Circuit For Slip Ring Induction Motor. , Setup To Conduct The Direct Load Test To Determine The Efficiency And Speed Regulation For Different Loads Of A Single Phase Induction Motor; Plot The Efficiency And Speed Regulation Curves With Respect To The Output Power. , Rotor Resistance Starter - 5H.P. 3-Ph, 400V (For Slip Ring Motor) , D.O.L Starter - 3H.P. 400V, 3-Ph; , Star Delta Starter - 5H.P., 3-Ph, 400V, Manual; , Star Delta Starter - 5H.P., 3-Ph, 400V, Automatic; , Variac (Autu Transformer) - Single Phase Portable Table / Floor Mounting Nclosed Input 230V A.C., Output 270V A.C., 50-60Hz, 15 Amp, Air Cooled , Variac (Autu Transformer)- Three Phase 415V A.C., Output 470V A.C., 50-60Hz, 15Amp, Air Cooled , Setup To Perform The Direct Loading Test To Determine The Regulation And Efficiency, Oc And Sc Tests (Synchronous Impedance Method), To Plot The V Curves And Inverted V Curves Of Three Phase Alternator. , Setup To Plot Current – Voltage (I-V) Characteristics Of Poly Crystalline Silicon Solar Cell And Find Out The Solar Cell Parameters. , Setup To Measure Beam, Diffuse And Global Radiation On Horizontal And Tilted Surface Using Pyranometer And Plot Radiation Vs. Time Characteristics For Certain Duration. , Setup For Characterization Of A Solar Flat Plate Collector And Evaluate Its Parameters. , Setup For Characterization Of A Solar Concentrating Collector And Evaluate Its Parameters. , Setup To Measure Thermal Performance Of A Solar Cooker With Varying Reflector. , Solar Street Lighting System For Dc Supply. , Set Up A Small Wind Turbine (Swt) System And Identify Its Specified Components. , Study Of Different Parts Of Water Turbines Such As Pelton Wheel, Francics And Kaplan. , Set Up Of A Anaerobic Digestion Biogas Plant To , Set Up For Induction Type Over Voltage / Under Voltage Or Over Current/ Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor To Plot The Characteristics , Jumper Wire: Single Stranded, Insulated Wire(Copper) 0.5Mm Dia , Jumper Wire Cutter: Self Adjusting Cable/Wire Cutter Stripper - Automatic Stripping Tool For Cables Up To 6 Mm , Twizzer , Magnifying Glass , 3-Phase Trms Multifunction Meter For 3Phase-3Wire/3Phase-4Wire Balanced Or Unbalanced Systems , Transmission Line Trainer Kit , D.C Network Analyzer , Hrc Fuse Link Cylindrical: Rated Current (A) :6A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :10A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :16A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :20A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 50/5A, Burden: 5Va, Accuracy Class: 0.5, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Current Transformer (Ct): Rectangular Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Hrc Fuse Link: 16A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Hrc Fuse Link: 10A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Miniature Circuit-Breaker (Mcb): 6A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 6A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Mccbs: 240V Ac Dy 125U With Thermal Magnetic Release , Mccb: Four Pole, 100 Amp, 25Ka Breaking Capacity , Earth Leakage Circuit Breakers, 25A, 30Ma, 2 Pole, 230V Standard , Earth Leakage Circuit Breakers, 32A, 100Ma, 2 Pole, Standard , Rccb: 32A, Type-Ac, 100Ma , Rccb 4 Pole 16 Amp/30Ma 240 V Residual Current Circuit Breaker , Shunt: 50A, 75 Mv, Class 1.0% For Extension Of Range Of Ammeter , Static Over Current Relay Trainer Kit , Trainer Kit To Study The Speed Control And Reverse Operation Of A.C. Servo Motor , Trainer Kit To Study The Speed Control, Reverse Operation And Position Control Of D.C. Servo Motor: , Trainer Kit To Study Percentage Differential Protection Of Transformer, To Plot Characteristics Of % Biased Differential Relay, Pickup Test For Differential Relay, Transformer Protection For In Zone Trips Faults And Transformer Out Zone Or Non Trip Faults. , Setup To Perform Experiment For Distance Protection Of Transmission Line Lg, Ll, Llg, Lll, Lllg And Auto Reclose Function Of The Relay For Transient Type Faults. , Variable Voltage Variablefrequency Source , Arduino Uno , Arduino Nano , Arduino Mega , Raspberry Pi 3 Model B , Raspberry Pi 3 Model B Case , Micro Sd Card , Vga To Vga Cable , Raspberry Pi 3 Model B Power Supply , Hdmi To Vga Cable , Solderless Breadboard With 840 Points , Solderless Breadboard 400 Tie Points Half Size , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 140Mm X 90Mm (14 Cm X 9 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 80Mm X 55Mm (8 Cm X 5.5 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , Female Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Male Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Dot Matrix Ldc Display With 16 Characters X 2 Lines Green/Blue , Dc12v 3W Submersible Water Pump , Max7219 8X8 Led Dot Matrix Display Module , Hc-05 Bluetooth Module , Led 4-Digit Display Module , Sim900 Gprs Transfer Board Micro Sim Gsm Core Ttl Port Module For Arduino , 5Mm/12Mm, Photosensitive Ldr Light Sensor Module , Neo6mv2 Gps Module With Flight Controller , 650Nm 6Mm 5V Dc 5Mw Mini Laser Dot Diode Module , Universal 16 Key Matrix Module Membrane Switch Keypad 4X4 , 4X4 Matrix 16-Key Keyboard / Keypad Telephone Style , 2-Axis Joystick Module With Push Button Function , 3.3 To 5V Active Buzzer Alarm Module Sensor , L293d Motor Driver Module , Isd1820 Voice Recording Module With On Board Mic And Speaker , Isd1760 Voice Recording And Playback Module With On Board Mic And Speaker , Dc Plastic Gear Motor With Wheel: 12V, 150 Rpm, Side Shaft Bo (Battery Operation) Motor , Esp8266 Ch340 Nodemcu Wi-Fi Module , Wemos Esp8266 D1 R2 V2.1.0 Wifi Development Board , Coin Vibration Motor; Operating Voltage: 1.5-3 V , Atmega16: 8 Bit Microcontroller Individual Ic (Dip); Voltage Range: 2.7V To 5.5V;Operational Range: -40°C To +80°C , Mpr121 Breakout V12 Capacitive Touch Sensor Controller Module I2c Keyboard , Usb Cables A To B , Usb Cables Mini , Piezoelectric Sensor , Alligator Connectors , Hook-Up Wires , Hook-Up Wires , Rgb Leds , Leds (Red) , Leds (Green) , Leds (Blue) , Leds (Yellow) , Leds (White) , Timer Ic - Lm 555 , Ir Infrared Obstacle Avoidance Sensor Module For Arduino Smart Car Robot 3-Wire, Ir Module, Ir Sensor Module - Ml019 , Triple Axis Compass Magnetometer Sensor Module , Temperature And Humidity Sensor Module , Infrared Ir Sensor Receiver Module For Arduino , Arduino Ultrasonic Sensor , Tripple Axis Accelerometer Board , Pir Motion Sensor Detector Module Hc-Sr501 , Pulsesensor Heart Rate Beat Pulse Sensor Module Amplifier For Arduino Raspberry Pi Open Source With Cable Electronic Diy Tool , 2 Channel Dc 5V Relay Module,Optocoupler Low Level Trigger Expansion Board For Arduino Uno R3 Mega 2560 1280 Dsp Arm Pic Avr Stm32 Raspberry Pi , Sound Sensor Big Microphone Sensor High Sensitivity Sound Detection Module , Super Debug Soil Moisture Sensor Module Soil Hydrometer Humidity Detector For Arduino , Super Debug Ttp223 Based Capacitive Touch Sensor Module For Arduino , Metal Touch Sensor Module For Arduino , Rain Sensitive Sensor Module, Rain Drop Detection Sensor Module/Raindrops Humidity Sensor For Arduino , Flex Sensor 2.2? Bend Sensor For Hand Gesture Recognition , Dht11 - Temprature And Humidity Sensor Module , Lm35d Analog Temperature Sensor Module , Colour Recognition Sensor , Water Flow Sensor , Sound Detection Sensor Module , Analog Sound Sensor Microphone Module For Arduino , Power Bank , Rfid 13.56Mhz Reader Writer Module , Rf Transmitter Receiver Module 315Mhz Wireless Link Kit For Arduino , Male To Male Jumper Wires (20Cm) , Male To Female Jumper Wires (20Cm) , Female To Female Jumper Wires (20Cm) , Ka7805 Linear Voltage Regulator , Push Button Switches , Toggle Switch , 2A Digital Mq-2 Smoke Detection Sensor , Mq-135 Air Quality Sensor Hazardous Gas Detection Module For Arduino
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
12.
Power #10432291 Price Bid
tender for DISMANTLING OF 315MVA, 400/220KV TRANSFORMER, ERECTION OF 500MVA, 400/220KV TRANSFORMER ALONGWITH ASSOCIATED WORKS AT 400KV SUB STATION SARNATH, VARANASI Sl. No. Item Description 1 Dismantling of following old & used equipment by opening of nut - bolts, opening of jumpers, removal of earthing and safe shifting of LA upto store and all other associated works. 2 390KV LA 3 198KV LA (alongwith dismantling of structure & its shifting to storage place. 4 Shifting of following equipments from store to site, its erection alongwith required base modification of structure and all associate works, earthing etc. 5 390 KV LA 6 198 KV LA (alongwith structure) 7 Removal of HV / LV jumper pipe, Neutral earthing strip electrical connection including cutting of channel / angle iron and removal from foundation. 8 Complete dismantling the accessories of 315MVA Transformer (BHEL make AVAL repaired)after opening of jumpers, removal of earthing and opening of cable connection, draining out the T/F oil upto required level in 209 Lit. capacity of oil drum / tanker, removal of all radiators, conservator tank, oil pipe line, all bushings, turrets, fan motors, marshalling boxes, OLTC panel etc., blanking the radiator, oil pipe lines, conservator tanks, turret etc. with proper gasket alongwith nuts & bolts to complete the job satisfactorily including proper stacking. Blanking plates, nuts & bolts shall be provided by the department. All necessary labour T&P etc. shall be arranged by the contractor at his own cost. 9 Dismantling all water and air pipelines of Mulsifire system of 315MVA Transformer, it’s safe shifting to storage place. 10 Complete drain out of the Transformer oil in 209 Lit. capacity oil drums of 315MVA Transformer. 11 Create the vacuum in main tank and filling of nitrogen in 315MVA T/F main tank. 12 Shifting of main tank of 315MVA Transformer (BHEL make AVAL repaired) from plinth to storage platform upto 20 Meter distance. 13 Additional shifting of main tank of 315MVA Transformer (BHEL make AVAL repaired) as actual including all T&P and all other work required to complete the job satisfactorily. 14 After dismantling of 315MVA Transformer shifting of 400KV bushing, 220 KV & 33 KV bushing of Transformer, all fan & oil pump, motor, conservator tank, radiator to store including stacking of radiator to store including stacking of radiators. 15 Re-filling of Transformer oil in 315MVA main tank from 209 Lit. capacity oil drums by help of centrifuging machine after shifting of transformer at desired place. 16 Shifting of main tank of 500MVA T/F from storage place to plinth upto 20 meter distance. 17 Additional shifting of 500MVA T/F as actual including all T&P and all other work required to complete the job satisfactorily. 18 Providing of Dry Air at the time of opening of blanking plate for erection of 500MVA Transformer Main Tank and filling of dry air of dew point -400 C or better for completion of work. The work shall include connecting pipe as required for measurement of dew point values of dry air. 19 Complete erection of 500MVA Transformer by erection of Radiator, conservator tank, all bushings, their turret, connecting oil pipe, cooling fan, Motor drive mechanism of tape changer, RTCC panel, Oil pumps and associated oil pipelines etc. to complete the job satisfactorily including Vacuuming the main tank of the 500MVA Transformer and sustaining the required vacuum for complete removal of the moisture in main tank. Then 1st filling of oil and topping up of Transformer oil in tank, radiator, oil pipe lines, conservator tank etc. and attending the oil leakage if any and all other associated works for satisfactory completion of work, no T&P shall be provided by the department. 20 Complete evacuation of 500MVA Transformer main tank and filling of Dry Air of dew point - 400C or better in vacuum up to pressure of 0.25 Kg/Cm2 and the again. 21 Create the vacuum inside the Transformer Tank and sustain it for 24 Hrs. filling the oil step by step in 500MVA Transformer. 22 Filling the Transformer oil in oil tanker from drums by centrifuging machine to increase the BDV value in 500MVA Transformer (Approx. 110 KL) 23 Circulation of Transformer oil of 500MVA Transformer Tank or oil tanker by connecting centrifuging machine to be provided by the contractor, taking BDV value of oil and IR value of periodically, till the required BDV and IR value is obtained as per direction of supervising engineer (Approx. 110 KL). Centrifuging machine with operator and oil testing set shall be provided by the contractor at his own cost. 24 Fresh earthing of 500MVA Transformer body from two different points to Neutral bushing of Transformer with 75 x 10 mm / 50 x 6 mm M.S. Flat at a depth of 2200mm in the ground along with complete earthing of radiator, Marshling Box, OLTC Cubicle and other points at 2 points Neutral Bushing of transformer including painting by Green color paints in 2 coats. (M.S. Flat will be provided by the Department). 25 Connection of 500MVA T/F with laying of cable and termination in between Turrets, WTI, OTI, Buchholz relays, PRV, cooling fans, pumps, OLTC, Marshalling Box etc. with proper ferruling as per drawing. 26 Laying of control cable of various sizes from 500MVA Transformer marshalling Box, C.T., OLTC to relay / control panel including associated works as shifting from store. 27 Inter connection of L.A, of 400KV, 220 KV equipment of 500MVA Transformer of different type connectors, HV / IV Jumpers and clamp / P.G. clamp etc. including proper bending & jointing of 4” IPS Al. pipes and all other associated works to complete the job. Bending machine shall be arranged by the contractor. 28 Remodelling of mulsifyre for 500MVA, 400/220/33KV Transformer by using and laying of existing pipe lines of size 25mm, 40mm, 50mm, 65mm & 80mm GI Pipe Lines in overhead and using other useful components like deluge valve, QB detector, High Velocity Nozzle used in mulsifyre installed at existing 315MVA Transformer as per specification and site requirement, complete with associated work. 29 Supply & laying of following ‘B’ Class (IS: 1239) GI Pipe Lines overhead/ underground in addition to above item (1A) as per site requirement specification andcomplete with associated tees, Elbows / Bends, sockets, flanges etc. by due cutting, bending, fabricating and welding etc. of pipe lines including digging of earth trench 1 meter below ground level as well as below the bed of cable trenches & road crossing alongwith anticorrosive treatment by bituminous painting on outer surfaces and wrapping hot dipped bitumen jute in 2 layers of underground pipe lines & 2 coats painting of overhead pipe lines in P.O. red colour after applying of one coat of red oxide primer. Finally filling & levelling of earth including repairing / concreting of road crossing as per details below : 30 Supply & laying of 25 mm dia ‘B’ class GI pipe 31 Supply & laying of 40 mm dia ‘B’ class GI pipe 32 Supply & laying of 50 mm dia ‘B’ class GI pipe 33 Supply & laying of 65 mm dia ‘B’ class GI pipe 34 Supply & laying of 80 mm dia ‘B’ class GI pipe 35 Supply & laying of 100 mm dia ‘B’ class GI pipe 36 Supply & laying of 150 mm dia ‘B’ class GI pipe 37 Supply & erection of Pylon support of M.S pipe ‘B’ Class 80 mm dia with angle iron, U Bolts, flanges & nuts & bolt for new Mulsifire System. 38 Construction of Pylon support base for new Mulsifire System. 39 Dismantling of existing Shed and reconstruction of shed for new Mulsifire System using materials of existing shed for deluge valve of 315MVA. 40 Supply & fixing of pressure gauges for new Mulsifire System. 41 Supply & fixing of pressure switches for new Mulsifire System. 42 Supply & fixing of sluice valve 150 mm dia for new Mulsifire System. 43 Supply & fixing of ‘Y’ strainer of 150 mm dia for new Mulsifire System. 44 Supply & fixing of QB detectors of 790 C for new Mulsifire System addition to detectors of existing mulsifyre. 45 Supply & fixing of HV Nozzles K-18x800 for new Mulsifire System. 46 Providing & fixing of 150NB Deluge valve for new Mulsifire system 47 Supply of Bimetallic 220 KV CT Clamp suitable for twin Moose conductor complete with hot dip galvanized nut, bolt, spring, flat washer. 48 Supply of Bimetallic 220 KV Standard / Tandem Isolator clamp suitable for twin Moose conductor complete with hot dip galvanized nut-bolt, spring, flat washer. 49 Dismantling of old 245KV 1000/800/500 Amp. Current Transformer including removal of cable, earthing etc. and shifting to store safely. 50 Dismantling of old 245KV CT Junction Box including removal of cable, earthing etc. and shifting to store safely. 51 Erection of 220KV Main lattice type structure (BXM) required for twin moose Jack Bus Bar. The job. consist of shifting of structure parts, Nut & Bolts from store to erection site in switchyard, its erection as per relevant drawing and practice using flat washers etc. with each bolt. 52 Carriage of 220KV Main lattice type structure (BXM) from other Sub Station / Place (Distance approx. 150 Km.) 53 Erection of 245 KV 2000/1600/1000 A Current Transformer in 220 KV Bay of 500MVA transformer as per instruction manual of various equipment and technical specification, proper earthing and shifting of material from store to site including all other associated works to complete the job. 54 Erection of 245 KV CT Junction Box in 220 KV Bay of 500MVA transformer as per instruction manual of various equipment and technical specification, proper earthing and shifting of material from store to site including all other associated works to complete the job. 55 Providing and fixing of 245KV S&S make male contact arm assembly for 2000 Amp. made of Aluminium Rod on side connecting the male contact solid core with U type housing and another side connecting the contact finger matching another side 20x6 mm copper fingers including dismantling of old 1250 Amp. 220Kv arm assembly and fixing new 2000 Amp. assembly proper checking alignment and Adjustment. 56 Providing and fixing of 245KV S&S make female contact arm assembly for 2000 Amp.made of Aluminium Rod one side connecting the fixing Jaw assembly with 20x6mm copper finger complete with main arm, another side connecting the contact finger matching wit rotary rod including dismantling of old 1250 Amp. assembly, proper checking alignment and adjustment. 57 Providing and fixing of 245KV S&S make Rotary head assembly made of aluminium alloy housing-mounting arranged up on insulator in centre connecting clamp including dismantling of old Rotary head assembly and fixing of new rotary 2000 Amp. proper checking alignment and adjustment. 58 De-Stringing & dismantling of existing 220KV Jack Bus Bar (Approx. length 75 Meter) of single ACSR Moose conductor of 220KV Bay of existing 315MVA Transformer - IV including De-hoisting of Disc Insulator strings of Tension & fittings from gantry alongwith shifting of the old conductors and fittings etc. from switchyard to sub station stores. (1 Job. for each Bays of each section of the Bus Bar). 59 Stringing & proper sagging of 220KV Jack Bus Bar section (R, Y & B phase) for 500 MVA, 400/220/33 KV Transformer by twin Moose conductor, the work includes carriage of conductor from store to site, straightening, cutting & bending fitting of hardware, spacers etc. alongwith hoisting of 120 KV disc insulator string etc. with all cost of men and T&P required for the job. Approx. length 75 Meter (R, Y & B phase) 60 Bay wise interconnection of equipment with twin moose conductor of R, Y & B phase at 220 KV Bus Bar to standard Isolator of Bus - I ( 1E/S), Tandem Isolator of Bus- II, Line Isolator (2E/S) and Tandem Isolator of Transfer Bus including cutting, bending to proper shape, size fixing with clamp and all associated works as per specification. 61 Breakdown Voltage Test, Water Content Test, Dielectric Dissipation Factor Test, Resistivity and Dissolved Gas Analysis (as per IS Norms) along with collection charges of 1 No. Oil Samples (1st Oil Sample for testing will be taken before charging) of new 500MVA, 400/220KV Transformer. Dissolved Gas Analysis (as per IS Norms) along with collection charges of 3 No. Oil Samples (2nd Oil Sample for testing will be taken after 24 hrs. of charging) of new 500MVA, 400/220KV Transformer, 3rd Oil Sample for testing will be taken after 7 days of charging and 4th Oil Sample for testing will be taken after 1 month of charging. 62 Providing Electrical Safety clearance from Office of the Director Electrical Safety, Gomti Nagar, Lucknow by submitting Electrical inspection fees through Challan for Energisation of 1 no. 500MVA, 400/220KV Transformer.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
13.
Power #10421753 Price Bid
Tender For Renovation Of C/R building, Development Of Yard,Raising Road Level And Other Miscellaneous Civil Works At 33 Kv S/S Rajgarh - 1 PART-A 2 (B-162/14.55)Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 3 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 4 (B-54/3.1.6)Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) 5 (B) M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (3.1.2) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 (B-107/10.16)Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 8 (B-72/6.15)Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 9 (B-65/5.2.2)Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 10 (B-66/5.8.3)Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 11 (B-139/12.3.2)Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. 12 (B-139/12.5)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 13 (B-139/12.3.1)25 mm thick 14 (B-144/12.37.3)Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 15 (B-142/12.22.1)Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A) New Plastered Surface (three or more coats) 16 (B-144/12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer. 17 (B-145/12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 18 (B-146/12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(A) Two or more coats on new work 19 (B-146/12.46.2)(B) One or more coats on old work. 20 (B-15.29)Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roofslabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 21 (B-109/10.22)Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 22 (B-56/3.8)Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 23 (B-101/9.19.3)Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) 24 (B-102/9.26)Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 25 (B-102/9.27)Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 26 (B-133/11.26)Random rubble dry stone Kharanja under floor. 27 (B-98/9.5)Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 28 (B-72/6.17.3)Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. 29 (B-100/9.17)Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 30 (B-93/8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick .Commercial Veneer both side 31 (B-93/8.14)Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 32 (B-146/12.45.1)Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 33 (B-72/6.18.1)Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 34 (B-152/13.24)Labour charges for repair to door / window with out using any material such as applying randha ( finishing ) tightening of bolts & screw etc 35 (B-150/13.4.1)Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm 36 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 37 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 38 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 39 (B-104/9.38.3)Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm 40 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 41 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 42 (B-/9.39)P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. 43 (B- /8.33)Providing and fixing Almirah lock (50 to 70 mm size )of approved makewithout pair of handles for door with necessary screws etc completeas per direction of Engineer-in-charge. 44 (B- /13.12)Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 45 B-/16.58)Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 46 13.29/B-153Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried..ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 47 3.28Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. 48 (B-86/7.12)Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 49 (B-86/7.13)Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 50 (S-218/1.20.3)P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:PVC withPVCbend and superior internal fittings as per IS : 7231 . 51 (S-220/1.59)P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 52 (S-/1.65)P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 53 (S-/2.33.5)Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 54 (S-231/2.6.5)P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:C.P. Pillar cock, high-neck, 15 mm nominal bore. 55 (S-223/1.43.1)P& F waste Pipe with all fitting P.V.C with C.Pnut 32 mm 56 (S-218/1.14.1)P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. . 57 (S-223/1.45.1)P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm 58 (S-221/1.36.3)P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm 59 (S-224/1.47.8)P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type 60 (S-225/1.52.1)P & F Soap Dish or Tray of approved quality / make C.P. brass 61 (S-240/2.38.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size 62 (S-240/2.38.4)(B) 32mm nominal size 63 (S-240/2.39.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).(A) 20 mm nominal size 64 (S-240/2.39.4)(B) 32 mm nominal size 65 (S-233/2.12.1)P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 66 (S-232/2.7.3)P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 67 (S-233/2.14.9)P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :Brass / GunmetalHalf-turnwt. 1 Kg.ofapprovedquality / make,25mmnominalbore. 68 (S-233/2.15.1)P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make:Gun metal 15 mm nominal bore 69 (S-233/2.15.3)Gun metal 25 mm nominal bore 70 (S-233/2.13.7)P & F 15 mm. Dia Connection Pipe of approved quality/make :CP Brass Pipe with CP Brass nuts upto length 450mm. 71 (S-236/2.26.3)P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 72 (S-232/2.11.2)P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ballcomplete :Brass wt. Not less than 400 gm, 20mm. 73 (S-247/3.16.2)P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.(b)75 mm dia 74 (S-247/3.16.3)(b)110 mm dia 75 (S-244/3.3.1)Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe)100mm dia S.W. pipe 76 (S-248/3.17.9.(ii))P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.5-110 mm dia 77 (S-249/3.17.12(ii))Vent Cowel 110 mm dia 78 (S-248/3.17.3(ii))Plain Tee110 mm dia 79 (S-249/3.17.15(ii))Pipe Clip 110 mm dia 80 (S-251/3.21.2)Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 x 450mm depth upto 0.5 M Cement cover with frame 81 (S-255/3.38.1)Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating 82 (E-07/3.1.1)Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box , 10 A Modular switch,Modular faceplate with grid plate, 3 pin ceiling rose/holder /3 way Connector,screws,making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Short point (up to 3 mtr.) 83 (E-07/3.1.2)Medium point (up to 6 mtr.) 84 (E-07/3.1.3)Long point(up to 10 mtr..) 85 (E-08/3.3.1)Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box,modular 10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR:On board 86 (E-9/4.1.7)Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm 87 (E-9/4.1.14)2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 88 (E-8/3.4.2)S&F following sizesof ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm x 12 mm 89 (E-33/7.36)Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 90 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating(E-17/6.1.1.2) 91 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 63 A Rating (E-18/6.2.1.2) 92 (E-22/6.10.1.2)Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metaldoor (single phase) IK-09 and IP-43 with Metal end box 6 way(6+2) 93 (E-30/7.26)Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 (E-30/7.21)Providing & Fixing of IS 11037:1984markednon modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 (E-81/15.7.3)Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 96 (E-88/17.4.2.2) Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Moutning Minimum lumen output 3600 lm 97 (E-82/15.15.1)Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Wall mounting type with Adjustable Vertical Angle 98 (E-95/18.12.6)Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LLED Street Light fixture with Minimum lumen output 11225 lm 99 (E-95/18.12.2)LED Street Light fixture with Minimum lumen output 3700 lm 100 (E-96/18.18.3)PProviding & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 mm Dia. 101 P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required.Group2E071400Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.12) 102 P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required.Group2Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.13) 103 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing (E-87/17.2.2) 104 (E-56/11.2.1.1)Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0sqmm 2core. 105 (E-90/17.9.3)Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 Watt 106 (E-82/15.12.1)Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .300 mm sweep(900/1400 RPM) 107 11.38.3(A)Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 108 11.39Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. 109 11.40Add extra over rates of item No. 11.38, A to C if colored paver blocks are used 110 7.52Providing and fixing machine pressed cement concrete (M-20) compressed with hydraulic compression machine kerbs or dands of size upto 60cm length as per drawing, jointing with cement mortar (1:3) over 20 mm thick base cement mortar (1:6) & painting the exposed surface with enamel paint of approved brand complete work as per direction of Engineer in charge size 15 cm x 38 cm. 111 17.1Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 112 9.3.1Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 113 (B-175 /16.1.1.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 114 (B-175 /16.1.2.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 115 (16.10.2)Providing and fixing expanded grill made of aluminum as per designand drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum ( minimum thickness of powder coating 50micron) 116 (B-176/16.5.2)Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 117 (B-176 /16.4.1)Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 118 (B-177/16.8)Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 119 (B-177/16.9.3)Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium . 120 (B-176/16.6.1)Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate 121 (B-95/8.27)Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. 122 (R-19/5.3)Providing, laying, spreading and compacting stone aggregate of as per table 400-10 and 400-11 Wet mix macadam specifications including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by tipper to site laying in uniform layers with motor grader/F.E.Loader/Paver finisher, in sub base/base coarse on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specifications : Clause 406) by mechanical mean with all lead. 123 14.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
14.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
15.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
16.
Power #10172978 AOC
Tender For Annual Maintenance Repair Of Md Dvvnl Office Vidyut Adhikari Colony At 220 Kv Sub Station, Sikandra, Agra - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR )(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. (DSR )(DSR 2.27) 8 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 9 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (DSR 2.29) All kinds of soil (DSR 2.29.1) 10 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 11 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 12 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.32) 13 Supplying chemical emulsion in sealed containers including delivery as specified. (DSR 2.34) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1) 14 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1) 15 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.2.1) 16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1) 17 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.4.1) 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (DSR 2.35.5) 19 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. (DSR )(DSR 2.36) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 22 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 23 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.11) 24 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 25 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 26 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III)including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)). (DSR 4.2.3A) 27 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.2.8) 28 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 29 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (DSR 4.3.2) 30 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Columns, piers, abutments, pillars, posts and struts (DSR 4.3.3) 31 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1) 32 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. (DSR 4.5) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (DSR 4.5.1) 33 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (DSR 4.6) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.6.1) 34 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1) 35 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. (DSR )(DSR 4.9) 36 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).(DSR )(DSR 4.11) 37 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 38 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 39 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 40 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 41 Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.4) 42 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.5) 43 Reinforced cement concrete work in chimneys, shafts, up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.6) 44 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). (DSR )(DSR 5.8) 45 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 46 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) 47 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 48 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 49 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 50 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 51 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 52 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Chimneys and shafts (DSR 5.9.11) 53 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards(DSR 5.9.13) 54 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 55 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 56 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 57 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 58 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 59 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 60 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) 61 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) 62 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 63 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 64 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 66 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 67 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 68 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 69 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1) 70 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2) 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of all colour and texture except black, Cherry/Ruby red 8.2.3 Area of slab over 0.50 sqm (DSR 8.2.3.2) 72 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 73 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 74 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 75 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 76 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 77 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 78 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 79 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 81 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR )(DSR 8.32) 82 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 83 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 84 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 85 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 86 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 87 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 88 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 89 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 90 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 91 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 92 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 93 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 94 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 95 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 18 mm thick (DSR 9.18.1) 96 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 25 mm thick (DSR 9.18.2) 97 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) 98 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.2) 99 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws (DSR 9.20.3) 100 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 101 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 102 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.21.3) 103 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). (DSR 9.25) Decorative type door (DSR 9.25.1) 104 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR )(DSR 9.26) 105 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1 Second class teak wood (DSR 9.27.1.1.1 ) 106 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) With ISI marked stainless steel butt hinges of required size 9.27.1.2 Second class teak wood (DSR 9.27.1.2.1) 107 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.2.1 Second class teak wood (DSR 9.27.2.1.1) 108 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) With ISI marked stainless steel butt hinges of required size 9.27.2.2 Second class teak wood (DSR 9.27.2.2.1) 109 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50x12 mm (DSR 9.40.1.1) 110 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50 x 20 mm (DSR 9.40.1.2) 111 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 112 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x20 mm (DSR 9.40.2.2) 113 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 20 mm dia (heavy type) (DSR 9.47.1) 114 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2) 117 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 125x90x4.00 mm (DSR 9.56.1) 118 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 100x75x3.50 mm (DSR 9.56.2) 119 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 75x60x3.10 mm (DSR 9.56.3) 120 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 121 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 122 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 123 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1) 124 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2) 125 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3) 126 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1) 127 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2) 128 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3) 129 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1) 130 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 131 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1) 132 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 133 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 134 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4) 135 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). (DSR )(DSR 9.64) 136 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 300x20x6 mm (DSR 9.65.1) 137 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 250x20x6 mm (DSR 9.65.2) 138 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 139 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 140 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 141 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 150 mm (DSR 9.67.1) 142 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 115 mm (DSR 9.67.2) 143 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 90 mm (DSR 9.67.3) 144 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 125x64x1.90 mm (DSR 9.70.1) 145 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 100X58X1.90 mm (DSR 9.70.2) 146 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 75x47x1.80 mm (DSR 9.70.3) 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 50x37x1.50 mm (DSR 9.70.4) 148 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 125x64x2.50 mm (DSR 9.71.1) 149 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 100x60x2.50 mm (DSR 9.71.2) 150 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 75x50x2.50 mm (DSR 9.71.3) 151 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 250x10 mm (DSR 9.74.1) 152 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 200x10 mm (DSR 9.74.2) 153 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 150x10 mm (DSR 9.74.3) 154 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 100x10 mm (DSR 9.74.4) 155 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.76) 156 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.77) 157 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR )(DSR 9.83) 158 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR )(DSR 9.84) 159 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 150 mm (DSR 9.87.1) 160 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 115 mm (DSR 9.87.2) 161 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 90 mm (DSR 9.87.3) 162 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.88) 163 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (DSR )(DSR 9.89) 164 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 40 mm (DSR 9.90.1) 165 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 50 mm (DSR 9.90.2) 166 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 65 mm (DSR 9.90.3) 167 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 75 mm (DSR 9.90.4) 168 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. (DSR )(DSR 9.91) 169 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) 170 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 100 mm (DSR 9.92.2) 171 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 75 mm (DSR 9.92.3) 172 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. (DSR )(DSR 9.93) 173 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 125x63x4 mm (DSR 9.95.2) 174 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 100x63x3.2 mm (DSR 9.95.5) 175 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 75x63x3.2 mm (DSR 9.95.7) 176 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 300x16 mm (DSR 9.96.1) 177 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 250x16 mm (DSR 9.96.2) 178 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 300x10 mm (DSR 9.97.1) 179 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 250x10 mm (DSR 9.97.2) 180 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 200x10 mm (DSR 9.97.3) 181 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 150x10 mm (DSR 9.97.4) 182 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 100x10 mm (DSR 9.97.5) 183 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. (DSR )(DSR 9.98) 184 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (DSR )(DSR 9.99) 185 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 125 mm (DSR 9.100.1) 186 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 100 mm (DSR 9.100.2) 187 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 75 mm (DSR 9.100.3) 188 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Single rubber stopper (DSR 9.101.1) 189 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Twin rubber stopper (DSR 9.101.2) 190 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.103) 191 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod. (DSR )(DSR 9.104) 192 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. (DSR )(DSR 9.110) 193 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Triple strip vertical type (DSR 9.114.1) 194 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Double strip (horizontal type) (DSR 9.114.2) 195 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.115) 196 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) (DSR )(DSR 9.116) 197 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. (DSR 9.126) Marine plywood conforming to IS: 710 (DSR 9.126.1) 198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.5 mm thick (DSR 9.127.1) 199 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.0 mm thick (DSR 9.127.2) 200 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge (DSR )(DSR 9.129) 201 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters (DSR 9.134.2) With ISI marked stainless steel butt hinges of required size 9.134.2.2 Second class teak wood (DSR 9.134.2.2.1 ) 202 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. (DSR 9.135) With 2nd class teak wood beading 62X19 mm (DSR 9.135.1) 203 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 125 mm (DSR 9.165.1) 204 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 100mm (DSR 9.165.2) 205 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 75 mm (DSR 9.165.3) 206 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). (DSR 9.166) 18 mm thick (DSR 9.166.1) 207 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 9.167) 208 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)(DSR )(DSR 9.168) 209 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge.(DSR )(DSR 9.169) 210 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. (DSR 9.17) 200 mm (DSR 9.170.1) 211 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 9.171) 212 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.172) 213 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensilbasket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) (DSR )(DSR 9.173) 214 Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.174) 215 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 216 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.2) 217 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1) 218 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2) 219 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1) 220 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 222 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 223 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 224 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (DSR 10.25.1) 225 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 226 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1) 227 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) E.R.W. tubes (DSR 10.26.2) 228 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 229 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 230 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 231 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR )(DSR 10.31) 232 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1) 233 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2) 234 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 235 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 236 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1) 237 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR )(DSR 11.7) 238 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1) 239 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Dark shade pigment using ordinary cement (DSR 11.20.3) 240 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Ordinary cement without any pigment (DSR 11.20.4) 241 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1 Acid and alkali resistant tile (DSR 11.21.1.1) 242 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2 Acid and alkali resistant tile (DSR 11.21.2.1) 243 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5) 244 Extra for pre finished nosing to treads of steps of marble stone. (DSR )(DSR 11.24) 245 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR )(DSR 11.25) 246 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 247 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 248 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. (DSR 11.28) Red sand stone (DSR 11.28.1) 249 Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR )(DSR 11.32) 250 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 251 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 11.37A) 252 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (DSR )(DSR 11.38) 253 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 254 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1) 255 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 11.45) 256 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 257 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades.(DSR )(DSR 11.49A) 258 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR )(DSR 11.50) 259 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 260 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 261 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (DSR 12.45) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (DSR 12.45.1) 262 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (DSR 12.47) 2 mm thick flat (DSR 12.47.2) 263 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. (DSR 12.52.4) 264 Providing and fixing tiled false ceiling of specifiedmaterials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.58) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (DSR 12.58.1) 265 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (DSR 12.59) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. (DSR 12.59.1) 266 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 267 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Ridges plain (500- 600mm) (DSR 12.66.1) 268 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Crimp curve (DSR 12.66.5) 269 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Gutter (600 mm over all girth) (DSR 12.66.6) 270 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 271 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 272 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 273 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 274 Neat cement punning. (DSR )(DSR 13.18) 275 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 276 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 277 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 278 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1) 279 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1) 280 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2) 281 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3) 282 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1) 283 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. (DSR )(DSR 13.59) 284 Lettering with black Japan paint of approved brand and manufacture (DSR )(DSR 13.71) 285 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 286 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 287 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1) 288 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2) 289 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1) 290 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2) 291 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1) 292 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3) 293 White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1) 294 White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2) 295 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 296 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 297 Painting with oil type wood preservative of approved brand and manufacture: (DSR 13.97) Old work (one or more coats) (DSR 13.97.1) 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 299 Re-lettering with black Japan paint of approved brand and manufacture. (DSR )(DSR 13.105) 300 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. (DSR )(DSR 13.106) 301 Finishing walls with textured exterior paint of required shade : (DSR 13.11) Old work (One or more coats) applied @ 1.82 ltr/10 sqm. (DSR 13.110.2) 302 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 303 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 304 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) 305 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2) 306 Varnishing with varnish of approved brand and manufacture: (DSR 13.113) One or more coats with copal varnish (DSR 13.113.1) 307 Melamine polishing on wood work (one or more coat). (DSR )(DSR 13.114) 308 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR )(DSR 13.116) 309 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1) 310 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2) 311 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR )(DSR 14.3) 312 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1) 313 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 314 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.5.2) 315 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1) 316 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.7.2) 317 Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2) 318 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 319 Refixing old glass panes with putty and nails (DSR )(DSR 14.10) 320 Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR )(DSR 14.11) 321 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR )(DSR 14.12) 322 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR )(DSR 14.17) 323 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel 50 mm dia and below (DSR 14.22.1) 324 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel above 50 mm dia (DSR 14.22.2) 325 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (DSR )(DSR 14.23) 326 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.1) 327 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.2) 328 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.1) 329 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.2) 330 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR )(DSR 14.29) 331 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1) 332 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2) 333 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3) 334 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4) 335 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5) 336 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. (DSR )(DSR 14.41) 337 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR )(DSR 14.75A) 338 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR )(DSR 14.76) 339 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm(DSR )(DSR 14.77) 340 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (DSR )(DSR 14.78) 341 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 342 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 343 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 14.81) 344 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 345 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (DSR )(DSR 14.83) 346 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall (DSR )(DSR 14.84) 347 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR )(DSR 14.85) 348 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 349 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 350 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 351 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 352 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 353 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area beyond 3 sq. metres (DSR 15.12.2) 354 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area 3 sq. metres and below (DSR 15.13.1) 355 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area beyond 3 sq. metres (DSR 15.13.2) 356 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) R.S. Joists (DSR 15.17.1) 357 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) Channels, angles, tees and flats (DSR 15.17.2) 358 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR )(DSR 15.18) 359 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 360 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 361 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 362 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) Asbestos Cement sheet (DSR 15.28.2) 363 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR )(DSR 15.36) 364 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) 15 mm to 40 mm nominal bore (DSR 15.44.1) 365 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) Above 40 mm nominal bore (DSR 15.44.2) 366 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: (DSR 15.45) Up to 150 mm diameter (DSR 15.45.1) 367 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.48) 368 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.49) 369 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 370 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres (DSR 15.53) Up to 150 mm diameter (DSR 15.53.1) 371 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. (DSR )(DSR 15.54) 372 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 373 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR )(DSR 15.57) 374 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 375 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 376 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1) 377 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1) 378 Supplying at site : (DSR 16.15) R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). (DSR 16.15.1) 379 Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2) 380 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) 381 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1) 382 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR )(DSR 16.19) 383 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. (DSR 16.31) With medium setting bitumen emulsion 16.31.2 On bituminous surface @ 0.25kg/sqm (DSR 16.31.2.2) 384 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.33) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.33.1) 385 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR )(DSR 16.40) 386 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 387 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 388 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR )(DSR 16.45) 389 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 390 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.64) 391 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.67) 392 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 393 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR )(DSR 16.69) 394 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 395 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 396 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 397 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 398 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR )(DSR 16.83) 399 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). (DSR )(DSR 16.84) 400 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR )(DSR 16.89) 401 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 402 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 403 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 404 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) 405 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (DSR 17.3) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.3.1) 406 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (DSR 17.7.3) 407 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) 408 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked (DSR 17.7.9) 409 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.11) 410 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 411 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: (DSR 17.9) White glazed fire clay kitchen sink of size 600x450x 250 mm (DSR 17.9.1) 412 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink with drain board510x1040 mm bowl depth 200 mm (DSR 17.10.1.3) 413 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink without drain board 17.10.2 610x510 mm bowl depth 200 mm (DSR 17.10.2.1) 414 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. (DSR )(DSR 17.15) 415 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR )(DSR 17.16A) 416 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1) 417 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : (DSR 17.2) White solid plastic seat with lid (DSR 17.20.1) 418 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR )(DSR 17.22A) 419 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia (DSR )(DSR 17.22B) 420 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR )(DSR 17.23) 421 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR )(DSR 17.24) 422 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 630x450 mm (DSR 17.25.1) 423 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 424 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 450x300 mm (DSR 17.25.5) 425 Providing and fixing kitchen sink including making all connections excluding cost of fittings. (DSR 17.26) White glazed fire clay sink of size 600x450x250 mm (DSR 17.26.1) 426 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 427 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) 428 Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR )(DSR 17.29) 429 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR )(DSR 17.30) 430 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 431 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR )(DSR 17.33) 432 Providing and fixing toilet paper holder : (DSR 17.34) C.P. brass (DSR 17.34.1) 433 Providing and fixing toilet paper holder : (DSR 17.34) Vitreous china (DSR 17.34.2) 434 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 435 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms (DSR 17.69.2) 436 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms (DSR 17.70.1) 437 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms (DSR 17.70.2) 438 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR )(DSR 17.71) 439 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR )(DSR 17.72) 440 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (DSR 17.73.1) 441 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR 17.73.2) 442 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (DSR )(DSR 17.74) 443 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. (DSR )(DSR 17.75) 444 Providing and fixing PTMT urinal cock of approved quality and colour. (DSR 17.76) 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms (DSR 17.76.1) 445 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. (DSR 17.77) Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) (DSR 17.77.1) 446 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR )(DSR 17.78) 447 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR )(DSR 17.79) 448 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (DSR )(DSR 17.80) 449 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (DSR )(DSR 17.81) 450 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 451 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3) 452 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1) 453 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) 454 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 455 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) 456 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 40 mm nominal dia Pipes (DSR 18.9.5) 457 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 50 mm nominal dia Pipes (DSR 18.9.6) 458 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 80 mm nominal dia Pipes (DSR 18.9.8) 459 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work (DSR 18.12) 80 mm dia nominal bore (DSR 18.12.8) 460 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 25 to 40 mm nominal bore (DSR 18.13.1) 461 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 50 to 80 mm nominal bore (DSR 18.13.2) 462 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (DSR )(DSR 18.14) 463 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 15 mm nominal bore (DSR 18.15.1) 464 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 465 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 15 mm nominal bore (DSR 18.16.1) 466 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 467 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 468 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 469 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 470 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 40 mm nominal bore (DSR 18.17.3) 471 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 80 mm nominal bore (DSR 18.17.6) 472 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1) 473 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2) 474 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1) 475 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2) 476 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Horizontal (DSR 18.19.3.1) 477 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Vertical (DSR 18.19.3.2) 478 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 80 mm nominal bore 18.19.6 Vertical (DSR 18.19.6.2) 479 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) 480 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 481 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 15 mm nominal bore (DSR 18.21.2.1) 482 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 483 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 100 mm diameter (DSR 18.22.1) 484 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 150 mm diameter (DSR 18.22.2) 485 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (DSR 18.27) 100 mm dia pipe (DSR 18.27.1) 486 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : (DSR 18.28) 100 mm diameter pipe (DSR 18.28.1) 487 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 80 mm diameter pipe (DSR 18.30.1) 488 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 100 mm diameter pipe (DSR 18.30.2) 489 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class I (DSR 18.31.1.1) 490 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class II (DSR 18.31.1.2) 491 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 492 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2) 493 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (DSR )(DSR 18.63) 494 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (DSR )(DSR 18.64) 495 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 496 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. (DSR 18.84) 15 mm nominal bore (DSR 18.84.1) 497 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 498 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) 499 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) 500 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (DSR 19.32) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) 501 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (DSR )(DSR 19.33) 502 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 503 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 504 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 505 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 506 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 507 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 508 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 509 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 510 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 511 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 512 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 513 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 514 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 515 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (DSR 21.8) Upto 5mm depth and 5 mm width (DSR 21.8.1) 516 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For fixed portion (DSR 21.9.1) 517 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For shutters of doors, windows & ventilators (DSR 21.9.2) 518 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). (DSR )(DSR 21.14) 519 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR )(DSR 21.17) 520 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 521 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11601 (DSR 21.19) Upto 5 mm depth and 5 mm width (DSR 21.19.1) 522 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11602 (DSR 21.19) Upto 10 mm depth and 10 mm width (DSR 21.19.2) 523 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR )(DSR 22.5) 524 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck ,using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR )(DSR 22.22) 525 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (DSR 23.1) All types of soil 23.1.1 300 mm dia (DSR 23.1.1.1) 526 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (DSR 23.2) All types of soil 23.2.1 350 mm dia (DSR 23.2.1.2) 527 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (DSR 23.3) 150 mm nominal size dia (DSR 23.3.2) 528 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4) 150 mm nominal size dia (DSR 23.4.2) 529 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.5) 530 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.6) 531 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR )(DSR 23.7) 532 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.8) 533 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR )(DSR 23.12) 534 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: (DSR 23.13) 150 mm dia (DSR 23.13.2) 535 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (DSR 23.14) 150 mm clamp (DSR 23.14.2) 536 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (DSR 23.15) 150 mm dia (DSR 23.15.2) 537 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR )(DSR 25.1) 538 Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardenthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (DSR )(DSR 26.10) 539 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : (DSR )(DSR 26.11) 540 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 541 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 542 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 543 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 544 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 545 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 546 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 547 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 548 Supplying and fixing 63 A, four pole, 415V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.13.2) 549 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 550 Smoke Detector with built in LED, mounting base complete with all connection etc. (DSR E&M 2022 4102) 551 Manual call boxes of MS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4103) 552 Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4104) 553 Response indicator on surface/recessed MS Box having two LEDs metallic covers complete with all connections etc.(DSR E&M 2022 4105) 554 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. (DSR E&M 2022 4106) 555 Fire alarm sounders (electronic) with facility to make announcement, mounted in A,B.S. Box with hinged cover plate & suitable for operation with amplifier l/c line matching ttransformer etc. (DSR E&M 2022 4107) 556 Talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. Knob & speaker/microphone enclosed in a M.S (16 SWG)/ABS.Box, break glass in front etc. (DSR E&M 2022 4108) 557 6 Zone fire alarm control panel as per IS: 2189 with backlit LCD (DSR E&M 2022 4110) 558 Cost of25 mm outer dia PVC/ABS Pipe with end caps including making air sampling operning of appropriate dia on appropriate interval. (DSR E&M 2022 4143) 559 Cost of fire survival armoured cable, fibre, fibre glass tape wrapped, ZH inner, outer sheath 2x1.5 sq. mm cable(DSR E&M 2022 4144) 560 Cost of fire alarm armoured FRLS cable 2 x 1.5 sqmm (DSR E&M 2022 4145) 561 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 562 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 563 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 564 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 565 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 566 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 567 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 568 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.37) 569 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 570 Supply & fixing steel tubular pole 7 Metre long designated 410 SP-2 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 2018 PWD 603 571 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 641 572 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 642 573 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131 574 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131(A) 575 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1132 576 Same as in item no. 1132 but of 6..5 kg. capacity 2018 PWD 1132 (A) 577 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 2018 PWD 1133 578 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 579 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 580 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 2018 PWD 1421CAT AA 581 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66Protection complete in all respects.2018 PWD 1425(A)CAT AA 582 Supply and fixing of3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. 2018 PWD 1441CAT AAA 583 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. 2018 PWD 1441 (A) CAT AAA 584 Supply and fixing ofdecorative 8 to 16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. 2018 PWD 1442CAT AAA 585 Supply and fixing ofdecorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and aboveprotection complete in all respect.2018 PWD 1443CAT AAA 586 Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 587 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 588 Supply and fixing of 200 mm Turbo ventilator Fan with ss Chimneycap & pipe of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 589 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 590 20-25 mm thick fine dressed Red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.(NSI) 591 Providing/Laying 20-25 mm thick fine dressed Red sand stone flooring including supply of all materials, labour and T&P required for proper completion of work as perdirection of the Engineer-in charge.(NSI) 592 Providing and fixing prefab structure of size which does not require any structural steel frame at all heights of the existing building with following specifications: Manufactured by Epack polymers pvt ltd /Pronto panels Or Equivalent make.Walls: Outer & Inner walls made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The wall panels shall be connected to each other with Cam Locks @ 1.00 m C/C The walls shall be connected to the the base platform with 1mm thick channels & 100 to 150mm long dash fasteners. The walls & ceiling shall be connected to each other by 1mm thick flashing as per the manufacturer specifications. Any number of vertical partitions are to be provided in the structure as required at site & as per the directions of the E-in-C complete. All the inner / outer gaps, if any, are to be filled with silicon, rubber gasket or any material required complete & directions of the Engineer in charge.Ceiling: Made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The ceiling shall be extended from the wall on all sides by not less than 450mm & not more than 600mm with neccessary slopes in wall as required at the site & directions of the Engineer in charge complete. The outer edges of the roof shall be covered with the channel of the same material as of puff panel.Doors: Made out of 50 mm thick PUF insulated panels inner/outer side cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. complete with providing & fixing all accessories like locks, SS hinges, SS Tower Bolts,SS handles of required size not more than 300mm.Windows: The frame work shall be of aluminium work (Powder coated aluminium (minimum thickness of powder coating 50 micron)) for doors, windows(Sliding/Openable as required with requisite handles, tower bolts,20mm dia SS curtain rod & any other fitting required ), ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be of thickness not less than 14gauge, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing with 5.50mm thick glass / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The outer surface shall have fly proof stainless steel grade 304 wire gauge, using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete .Strengthing of door, window, ventilators & any other opening : Any opening provided will have the framework strengthened with 1mm thick MS Plate on all sides all complete & directions of the Engineer in charge.Measurements: Only the floor area of the pre fab outer structure will be measured for payment purpose.Conditions Rates include all lifts, leads, depths, material, labour, scaffolding, all heights for location, carriage, wastage, tools and plants and other all inputs for execution of the item. The colour of the panels for walls & ceiling should be got approved from the E-in-C prior to start of manufacturing of the structure. The Structure requires approx five partitions in the two structures besides two outer walls . Note: The zinc sheet of the puff panels can either be plain/corrugated on both sides or one side plain & one side corrugated upto any pitch in horizontal / verticals per the drawings & requirement at site. 593 Supply,Installation, testing & commissioning Battery 12 V 7 AH Exide or equivalent make for above fire alarm system. Complete as per direction of the Engineer-in charge. 594 Supply,Installation, testing & commissioning Response Indicator Agni Suraksha or equivalent make. Complete as per direction of the Engineer-in charge. 595 Supply,Installation, testing & commissioning Camera (3 MP) colour W Audio IP Dome Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 596 Supply,Installation, testing & commissioning Camera (2 MP) IP Dome Falcon series Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 597 Supply,Installation, testing & commissioning NVR 8 channelSecureye or equivalent Indian make, with 4TBHDD Hard Disk. Complete as per direction of the Engineer-in charge. 598 Supply,Installation, testing & commissioning Connector D link or equivalent make Complete as per direction of the Engineer-in charge. 599 Supply,Installation, testing & commissioning 8 Port POE Switch Secureye or equivalent Indian make Complete as per direction of the Engineer-in charge. 600 Supply,Installation, testing & commissioning Cable (CAT6) D link or equivalent make Complete as per direction of the Engineer-in charge. 601 Servicing of Air Conditioner (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.30) 602 Servicing of Air Conditioner and filling of GAS (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.31) 603 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver setcomplete in all respect. 1401 PWD CAT AA 604 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. 1402 PWD CAT AA 605 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.1406 PWD CAT AA 606 P/F of 30 W orevo make or equivalent make LED light 30 Watt over Hoarding frame along boundary wall of MD DVVNL Campus, 220 KV S/S Sikandra , Agra with necessary materials , labour, T&P etc required for proper completion of the work as per direction of Engineer in charge. (NSI) 607 Providing and fixing of 20 W Philips make or equivalent make LED Tube light 20 Watt with necessary materials labour, T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI) 608 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 609 Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) 610 Printing name and designation of occupants and other information on residence block/office building including preparation of the base with best quality synthetic enamel paint as directed by E/I including cost of all materials, labour and T&P etc. required for proper completion of work. (NSI) 611 Providing and fixing of Name plate Acrylic/Glow sign Sheet per mm thick without letter as per approved shade and design as per direction of Engineer in charge (NSI) 612 Providing and Pasting of Name plate letter cutting words laser machine without name plate including cost of necessary all fittings such as nut, screws, labour T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI)
Contract Date: Apr 23, 2026 Contract Value : 21.94 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
17.
Educational and Research Institute #10000242 AOC
Tender For Construction Of Ctvs Transplant Ward In Aiims Raipur; 1 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 2 Centering and shuttering including strutting, propping etc. and removal of form for 3 Lintels, beams, plinth beams, girders, bressumers and cantilevers 4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5 Thermo-Mechanically Treated bars of grade Fe-500D or more. 6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 7 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. 8 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 9 Providing and fixing 15-17 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirtings and similar locations of required size, approved shade, colour and texture laid with epoxy resin based adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, cleaning, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red and any size: 10 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 11 40 mm 12 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 13 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 14 250x16 mm 15 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 16 200x10 mm 17 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 18 Twin rubber stopper 19 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 20 Double strip (horizontal type) 21 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 22 Providing and fixing to existing door frames. 23 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 24 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 25 100mm 26 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineerin- charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 27 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge 28 200 mm 29 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. 30 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 32 Size of Tile 600x600 mm 33 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 34 110 mm diameter 35 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc., wherever required. 36 Main ‘T’ runners to be suspended from ceilingusing G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted withpolyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 37 12 mm cement plaster of mix : 38 1:6 (1 cement: 6 fine sand) 39 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 40 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 41 Two coats 42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 43 In cement mortar 44 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 45 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 46 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 47 W.C. pan with ISI marked white solid plastic seat and lid 48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 49 White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap 50 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 51 Size 600x450x200 mm 52 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 53 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 54 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 55 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. 57 50 mm nominal dia Pipes 58 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 59 20 mm nominal dia Pipes 60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 61 25 to 40 mm nominal bore 62 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 63 20 mm nominal bore 64 Providing and fixing uplasticised PVC connection pipe with brass unions : 65 45 cm length, 15 mm nominal bore 66 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 67 15 mm nominal bore 68 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 69 15mm nominal bore 70 Providing and fixing PTMT grating of approved quality and colour. 71 Circular type 100 mm nominal dia 72 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 73 For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) 74 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron) 75 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. 76 Pre-laminated particle board with decorative laminationon both sides 77 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketn etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 78 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) 79 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 80 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixedm with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 81 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : 82 Providing and fixing in position Double bay stainless steel (304 grade) scrub station of size 1220x610x1500 mm with automatic sensor & foot operated tap with hot and cold water temperature controller valve and foot operated soap dispenser arrangement of approved make and quality as per the direction of engineer in charge. 83 Providing and fixing 44 mm thick HPL (Hinge Pressure Laminate ) Hermetic Hinge single Leaf Door for civil opening 1800(W)x2100 (H) with S.S. Ball bearing hinges , D Handles , both side key operation dead lock ,View window size 300x300 mm ,sealing gasket, Automatic Drop seal ,door seal and one door closer etc. all complete as per instructions of Engineer In charge. 84 Providing and fixing frosted film of make 3M/Avery/Oracal and of thickness not less than 1 mm over the glass of windows, glass partition etc including cutting of film in a certain design, shape all complete as per the instructions of Engineer In charge. 85 Providing and applying anti microbial epoxy PU flooring of thickness not less than 3 mm, in required colour, patterns etc. having anti skid properties,corners should be uniformly curved, final surface should be non corrosive to biological fluids, detergents etc. all complete as per the instructions of Engineer In charge. The execution of item shall involve activities of cleaning the surface, grinding of the cleaned surface by manual or mechanical means, applying PU flooring primer on the complete surface followed by screed activity to level the complete surface and then followed by applying PU Topcoat. The items to be used shall be of make BASF/ENDURA/MYK failing which the make approved by Engineer-in Charge shall be used. The work is to be executed and completed all as per manufacturers specification and as per direction of Engineer-in Charge. 86 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 88 Using M.S. angels 40x40x6 mm for diagonal braces 89 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 90 In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete 91 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 92 10 x 120 mm 93 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 94 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) 95 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. 96 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 97 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 98 Providing and fixing 50 mm thick galvanised Puf panel of make Jindal/Tata/JSW on the walls and roof (size, shape and pitch of corrugation as approved by Engineer-in-charge) . The sheet shall be fixed using self drilling /self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,including cutting to size and shape wherever required, Fixing operations of roof/wall panels shall be completed in all respect as per drawings and manufacturers specifications and under the overall direction of the Engineer-in-charge.Drawing and Layout of Puf Panel is to be submitted by the contractor for the approval of Engineer-in Charge. No separate amount is to be paid by the department to the contractor for drawing/layout 99 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit & accessories as required. 100 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 101 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 102 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 103 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 104 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 105 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 106 5/6 A switch 107 15/16 A switch 108 3 pin 5/6 A socket outlet 109 6 pin 15/16 A socket outlet 110 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 111 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 112 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 113 1 or 2 Module (75mmX75mm) 114 3 Module (100mmX75mm) 115 4 Module (125mmX75mm) 116 6 Module (200mmX75mm) 117 8 Module 118 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 119 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 120 1 run of cable 121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 122 100 A,30KA,FPMCCB 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 124 6 way (4 + 18), Double door 125 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 126 Single pole 127 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 128 63 A 129 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 130 63 A TP&N MCB 131 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 132 For 6 way, Double door TPN MCBDB 133 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 134 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). 135 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required. 136 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 137 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 138 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 139 40 A 140 Supply and laying of3.5*50 Sqmm 1.1 kV grade PVC Sheathed XLPE insulated aluminium armoured cable. 141 Supply and Installation of Exhaust fan suitable for single phase, 230 volts, 50 Hz, AC supply having RPM 1100or better , 300 mm sweep, power input = 35W or less, Air delievery ≥ 700 CFM complete with motor, louvers/ shutters etc. as required in the existing window, includes dismembering of window glass, providing and fixing ACP panel (6mm thickness Aluminium composite panel) framing in place of glass, connection, testing, commissioning etc. as required. 142 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 143 18 watt 144 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 145 36 watt 146 Supplying and Installation of clean room recess mounted 600X600 mm, 30-34 watt LED luminaries with lumen efficiancy of >100 lm/W, dimming option, highly specular anodized aluminum reflectors, optical antiglare system, high effiency polycarbonate diffuser with EMC/EMI compliant electronic driver having PF>0.9, THD < 10%, & minimum of 3kV surge/burst protection, complete with 50000 hrs burning for lifetime with supporting data sheet LM-79 & LM-80. Luminaries cover should be made of highly resistant, disinfectant proof laminated, safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The Recess frames should be gas tight. The white luminaries body should be made of sheet steel, perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear in multilamp technology. The Light fitting should be flush with the ceiling and should be removable from top or bottom. Optional pre-set color temperatures or adjust to any CCT in the Productivity Range 3000 K - 5700 K, Dimming Range 10%-100%The LED used in the luminaire shall be only Lumileds, Nichia, Cree, osram & LGIT and hanging with necessary chain etc as required. 147 Supply and Installation of 10 litre capacity Water Geysers in required locationequivalent to Jaquar model- EPM-WHT-V010* 10 liter capacity* Temperature Range:- 25-70ºC or better* Wattage:- 2KW or less* 5 star rating* suitable for single phase, 230 volts, 50 Hz, AC supply. 148 Supplying and Installation of 60 mm thick hermetically sealed single sliding door of ( 2.1 m (H) x 1.5m (W))/(2.1 m (H) x 1.8m (W)). The controller should be capable of being operated by elbow switches/ foot switches as well as touch less sensor. The track should be of Stainless steel/ Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door material should be of HPL colour should match the interior and care should be taken to make the leaf strong and light weight.The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/ Aluminum track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. One should be able to open and close the door effortlessly in case of failure of automatic mechanism. Door opening handle should be of SS (gloss finish), i/c high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing, Air tightness 99.99% at a pressure of 100KPa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be of 60mm. The inner part of the door should be filled with CFC free polyurethane foam. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. All motors used should be DC brushless motors with essentíal isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed motorized roller blind inside. The starting time after receiving the signal shauld be adjustable between 0.5 to 20 seconds. The complete door assembly should be BIS/ European CE marked/ US FDA approved. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.Hermatically Sealed HPL finish DOOR - Automatic with automation,Supply, Installation, Testing of automatic sliding hermatically OT door size of with Double sided wall frame with HPL Plank 400mm.1- Door Profiles- Aluminium Alloy, Grade 6063, Temper T6. Natural Anodized 20 μm.2-PIR. Dimensional stability at +100°C & -25°C (2%max).Density 41Kg/M3 with max deviation of 2kg/m3 as perDIN53420.3- Door Skin- HPL (4mm) both side of door4- Sealing Gasket (Sides and Top)- Replaceable Bulb and Lip design EPDM gasket.5- Sealing Gasket(Bottom)- .Replaceable Special lower sealing EPDM gasket.6-. Vision Panel- Double Glazed IG unit with 5mm tempered glass on both sides. Size = 300 mm x 300 mm x 60mm.7-Lever Handle- Solid AISI 304 Grade Stainless Steel with rubber spring system.8- Rail System- 6mm deep indentations with ‘down and in’ movement at the angle of 45⁰.9- Rollers- Special Grade Self-lubricating PA Bearings: 2X per roller.10-Wall Frame- Aluminium Alloy, Grade 6063, Temper T6 Natural Anodized 20 μm.11- Planks- HPL Planks finished with compact laminates are used to cover the door opening.12- Noise Insulation-28 dB.13- Air Permeability- Air Leakage at ± 100 Pa (pressure difference) = 0.07 m³/h.m. 1-Microprocessor Based controller. (230 Vac, 750 W (max),2- motor, IP65 protection Class, 20 Nm, 3Øx230V. (CE Marked).3- If an obstruction is present and prevents the door from closing, the intelligent automation sense with self reversal function thus eliminatingthe need for an ugly safety strip.4- Additional safety is provided by means of a photo cell fitted across the door opening.5- Variable options for the opening and closing speeds, time delay closing and part opening for pedestrian use and are easy to adjust.6- A self diagnostic coded system makes fault finding simple, reducing expensive down time.7- Magic (Hand) Switch- The spread of infection is controlled by automating the doors with touch less sensors allowing hands free operation.8- Foot switch or Elbow Switch- AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors.Control: Microprocessor-controlled with Deceleration Measurement System sliding door drive.Power supply: 230 Vac +10% / -15%. Frequency: 47-63Hz . Power Consumption -Maximum : 750 W.Drive :STG motor. Nominal Motor power:90 W, High Torque Motor -20Nm.Microprocessor controlled motor driver. Max. door weight : 350 Kg.Adjustable Speed Control level: 1-9 . Slow speed (V slow) :20(Threshold speed) - 120 mm. / sec.Starting speed (V start) :20(Threshold spped) - 220 mm. / sec. Opening speed (V open) :Threshold speed to 800 mm. / sec. Closing speed (Vclose):Threshold speed to 400 mm. / sec.Pedestrian opening (Half Opening width) :10% - 99% of the available door opening. 149 Supply ,Installation,Testing & Commissioning of factory built cabinet type unit withAl anodised thermal break frame structure injected with minimum 45+-5 mm thick PUFinsulation, GIPanelshallbepowdercoatedfrombothinnerandouterside,evaporationDxcoil expansion valve and corded remote ,Fan section with double width double inlet (DIDW backwards curved) centrifugal fan with Variable speed Fan Motor with VFD, prefilter section with EU3 / G4 class filters & EU-7 Filter(As per Approval of Engineer Incharge ) Dx coil.units shall be with a remote controller as per site requirement. Rating for the AHUs shall be as under - Motor selection (IE-3) to suit the below capacity AHU ratings. AHU shall be mounted on floor/Ceiling Mounted with vibration isolatorsUnit shall be with factory fitted inlet/outlet aluminium Aerofoil dampers. ,Temperature controller ,Door open switch ,pressure drop across filters ,Fan motor over load protector ,Suitable UV System Chamber complete with cable /wiring etc. will be part of this AHU Unit. AHUShouldhave1setofSpareFiltersapartfromCommissioningfiltersfixedinAHU. SuitableCommunication cable from indoor to outdoor is in the scope of agency .Double Skin Heater Bank Chamber comprising of SS 304 spiral strip heaters fitted with Porcelene blocks, Safety air stat & access door for heater rating , UVGI Lamp etc. As per per approved design from Engineer Incharge. AHU connection Kit with Control box (expansion valve ), Control Box,Nitrogen Testing ,Vaccuming , Green Refrigerant Top up .It should be equiped with Controler to control humidity up to 55 % (+-5%).AHU Machine should be Equipped withmotorised Fire Dampers .F.M./S.A Fan 4000 CFM /18 TR(24 HP) X 2 Numbers Coils / 6 ROW coil Full Copper , with two Stage Filter level 10 micron + 5 Micron,ESP-150 MM in WC. Design parameter- Temp.-21+-3 Degree Centigrade , Relative Humidity -55+-5% 150 Supply, Installation, Testing & Commissioning of 22 HP modular type variable refrigerant flow / Variable regrigerant Volume air cooled outdoor units suitable for cooling and heating having all hermatically sealed inverter type scroll compressor, minimum two compressor for above 14 HP modules, microprocessor based controller,top discharge type condensing units, with R410 A refrigerant, Vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Celcius ambient temperature without tripping. The unit shall be suitable to work on 400+/-10%, 3phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required with suitable communication cable. The COP at AHRI Conditions shall not be less than 3.1 and IEER not less than 6.5. 151 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 152 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 153 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 154 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 155 Supply, installation, balancing and commissioning of Site fabricated Aluminium 0.80 mm rectangular/Circularducting as requiredwith supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr) includes cutting/ dismanteling of wall (if required) and make good the same.Note: Fabrication and jointing of duct shall be as per IS standard and hanging shall be as per SMACNA. 156 Thickness 0.80 mm sheet 157 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. 158 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 159 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 160 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. 161 Fire Damper 162 Actuator 163 Supply and fixing of acoustic lining of AHU wall and ceiling with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to wall and ceiling with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 164 Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 165 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Drainage. 166 32 mm nominal dia. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit,fitting as required. 168 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 169 Supply ,Fixing and erection of Duct rexin Fire Retardent Canvass Connections with Vibration & Isolation Pad complete as required . 170 Supplying and fixing of MS of (40X40X5)mm stand for condensing (Outdoor) with epoxy painting, unit Size - 1040 mm(L)*440mm(W)*300(H)} . 171 8 SWG (Copper ) Earthing Cable Supply & Fixing complete as required . 172 Supply and fixing of 10 mm Open cellacoustic insulation of supply air duct and plenum with fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per direction of Engineer Incharge AIIMS Raipur. 173 Supplying, fixing, testing and commissioning of Hepa Filter of required Specification withincluding making arrangement for fixing complete as required and as per direction of Engineer-in-charge.Class-14,Efficiency -99.97 174 Supplying, fixing, testing and commissioning of 1 Tile Membrane Surgeon Control Panel of following Specification including making arrangement for fixing with necessary acessaries ,Cable etc. complete as required and as per direction of Engineer-in-charge. 175 Supplying, fixing, testing and commissioningofmotorised damper as required Specification withnecessaryarrangementas per direction of Engineer-in-charge. 176 Supply and fixing ofinsulation work with 6 mm nitrile rubber on existing CPVC drain pipe(32 MM) properly as required. 177 Supply, Installation and Testing of G I Sheet with Galvanized Coating cable tray cover for 225 mm powder coating M.S. cable trays it is highly durable and robust , corrosion and can sustain high load andincluding bolts & nutsall accessories as per specifications etc. as required. 178 Supplying, installation, testing and commissioning of M.V/LT. cubical type totally enclosed dust and vermin proof Floor/Wall mounted Sub Main Distribution Boards suitable for use on 430 V 3 phase 4 wire 50 Hz AC supply, having compartmentalized construction for different incoming/outgoing MCCBs from Approved Make, and separate bus bar & cable alleys , fabricated from min 1.6mm thick CRCA sheet steel of uniform width complete with copper bus bars , MV/LT danger notice plate, Digital type ammeter with Ammeter selector switch , voltmeter with Voltmeter selector switch , LED indicating lamps, cast resin CTs , Confirms to IEC-61439-2, IP-43, Interconnection with suitable capacity copper strips / rods, connection of incoming and outgoing cables with thimbles , smoke/Siemens grey colour stove enamelled painted and having following incoming and outgoing switchgears, 2 earth bolt, removable cable gland plate with spare suitable hole, wall/floor mounted, lockable using hollow standard LT Panel lock key complete as per site required or as approved by Engineer In-charge. A. INCOMER 01 nos. 250amps 35kA TPNL MCCB from Approved Make Thermo-magnetic release type with rotary handle. 01 nos. Digital type single function volt meter to show 0-500V voltage with phase selector switch01 nos. Digital type single function ameter to show amperage with phase selector switch 03 Nos Energy Meter 03 Nos CTs 125/5 ratio 03 LED Indication Light with toggle switches B. OUTGOING 08nos. 40A TPNL MCCB (25 KA) Thermo-magnetic release type. 179 Dismentlingwork of Existing installed duct, FCU, HVAC Pipelines, Starter Panelincluding Welding, Cutting as required as per direction of Engineer Incharge AIIMS Raipur. 180 Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying,installation,testing&commissioningofmanualcallboxesofMS constructionin surface/recesswithstainlesssteelchain&hammerassembly complete with glass and push button etc. as required. 182 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 184 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered along with battery arrangement for power backup complete with all connections, interconnections as required. 185 4 Zone 186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 187 Supply and fixing of 4 kg clean agent (HCFC) portable fire extinguisher having pressure guage indicator and arrangement for wall hangingand with warranty for 5 years on complete product. 188 Providing and fixing you are here sign board near entrance and fire reflective sign board, reflective stickers signage for indication at fire doors, fire extinguisher, fire exit with suitable size as per requirement and as per instruction from Engineer In-charge.
Contract Date: Apr 16, 2026 Contract Value : 1.09 Crore
Government Departments No of Bidders 4
Chhattisgarh View Result →
18.
Power #9921536 AOC
Tender For Material Supply, Spares & Special Tools - RGC - Construction of 33/110kV Step Up GIS at Pushpakandam-- 1 Design, Engineering, Manufacture, Testing at manufacturers works, Delivery at site including all materials, accessories such as OLTC,RTCC, with Transformer Oil and 10% extra Oil, spares,Gaskets, OTI,WTI,MOLG indicators with transducers and Tools as per specification , loading and unloading, transportation, handling, proper storage at siteThree Phase Two Winding Transformer33/110kV, 60MVA Capacity with optical sensors and Remote Data Transfer facility with optical communication media, and all other accessories complete, with SAS Integration Scope , all required valves and flanges for NIFPS shall be provided for transformer at the time of transformer design itself,inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 2 Design, Manufacture, Testing at Manufacturers works, Transportation and Delivery of 110 kV, 3 Phase Encapsulated Double Busbar Indoor Gas Insulated Switchgearequipmentand other accessories at Substation siteand as per respective Technical Specifications, Single Line Diagram, General Arrangement Drawings, IS/IEC standards, approval of KSEBLand relevant special conditions applicable. The quote for each bay shall include necessary interconnecting GI bus ducts within the building. The supply include all accessories of GIS bay, earthing materials for forming the earth grid inside the GIS hallas per standards of GIS earthing (Cu/Al), including RF Earthing, Cable tray, control cable from GIS to LCC, LCC panel, ladder etc. complete. 3 110 kV GIS Feeder Bay with PT(40kA/ 1250A min) 4 110kV GIS Double Bus bar arragement with PT(40kA/ 2500A min) 5 110kV GIS Bus Coupler Bay(40kA/2500A min) 6 110kV GIS Transformer Bay (40kA/1250A min) 7 Polymer housedSurge Arrester suitable for 110kV, 10kA, Class 3 withclamps, terminal connectors suitable for connection of any type of conductor or Al/cu pipe bus as per requirement, leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete 8 110kV composite solid core station post insulator , clamps, connectors etc suitablefor Al/ Cu Pipe Bus /Conductors. 9 Neutral CT (NCT) 36kV 3150Afor 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 1200-600/1-1 Amps(33 kV side) 10 Neutral CT (NCT) 36kV 3150A for 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 400-200/1-1 Amps(110 kV side) 11 UG power cable- 110kV, Single core, 630sqmm, Aluminium conductor,XLPE insulated,Aluminium Corrugated sheathedandHDPE Outer jacket under ground cable having rated short circuit capacity for both conductor and armourwith necessary Non - Magnetic , Metalic Trefoil/flat formation clamps atminimum 3 metre interval, steel/nylon cable ties wherever necessary 12 Outdoor termination kit suitable for 110kV, 630 Sqmm Single core Copper/ Aluminium UG cable for yard structure mountinginclusive of all accessories like earthing cable, suitable Non - Magnetic, Metalic clamp for fixing cable to support structure etc at 1m interval complete. 13 Indoor Plug in Type GIS termination kit for 110kV 630 Sqmm XLPE Single coreCopper/ Aluminium UG cable,inclusive of all accessories like earthing cable, suitable Non - Magnetic , Metalic clamp for fixing cable to support structure etc at 1m interval complete. 14 Supply of 4IPS Schedule 40 Al. Tube including requiredJointing Sleeves, Expansion joints, etc. withnecessary fixing clamp and all accessories complete for 110kV,33kV equipment to equipment connection 15 Three Phase Link Box 6.6kV withoutSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 16 Three Phase Link Box 6.6kV withSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 17 33kV Indoor composite VCBPanels having bus capacity 31.5 kA for 3sec, 3150A at STC continuous rating, 4 nos feeder bays having capacity not less than 1250A ,2 nos transformer feeder bays (for 33/110kV transformer) having capacity not less than 2000A ,1 nos transformer feeder bay ( for 33/11 kV5MVA Transformer ) having capacity not less than 1250A and1 nos bus coupler with bussection panel not less than 3150A, two bus PT panel at both side of the bus .Every feeder/incomer/ bus coupler shall have CT, E/S, synchro check, SEM Energy Meter, Ammeter, Voltmeter, Control and Protectionincluding earthing as per standards(Cu), cable tray, control cables etc completeand as per SLDand specifications. 33/110 kV 60 MVA Transformer feeder shall have provision for termination of cable size 3 runs per phase of 630 sqmm Aluminium cable. Each incomer panel (transformer) shall be provided with additional special protection class CT cores for differential protection scheme M1 and M2 at 110kV transformer C&R panel. All the feeders shall be remote controlled from SCMS and from the local console of the numerical relays with Bay Control Unit and protection unit including supply of the same. The supply includes one number VCBfor each ratings as spare (2000A, 1250A) and two numbers of service trolley for VCB , E/S, PT and spares (as per attached list clause 6.6 & 6.7 of volume 2, Chapter 27). 18 Polymer housedSurge Arrester suitable for 33kV, 10kA, Class-3 with clamps, terminal connectors etc. suitable for connection ofany type of conductor or Al /Cu pipe bus as per requirement, including leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete (33kV Feeder/ Transformer) 19 33kV 800A Triple Pole Line Isolator with Structure, clamps, terminal connectors etc. suitable for connection of any type of conductor or Al/Cu pipe bus as per requirement 20 33kV Pin insulator with pin 21 33kV composite solid core station post insulator with high level structure with clamp & connectors suitable for Al pipe/conductor. 22 UG power cable- 33kV 1Cx630sqmm Aluminium 33kV, XLPE Aluminium armoured having rated short circuit current capacity for both conductor and armour and HDPE outer jacket for 33/110kV 60MVA transformer incomer with necessary Non-magnetic, metallic, Trefoil/flat formation clamps at minimum 3 metre interval and steel/nylon cable tie wherever necessary 23 Outdoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core Aluminium UG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 24 Indoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core AluminiumUG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 25 Design, Engineering, manufacturing, testing at Manufactures worksite, supply, delivery,loading and unloading, transportation, handling, proper storage at site,supervisionof erection, testing and commissioning of 33/11kV, 5MVA three phase two windingtransformer as per technical speciationsincluding all materials, accessories such as Off Load Tap Changer, Transformer Oil and 10% extra Oil, spare Gaskets, OTI,WTI,MOLG indicators with transducers as per specification and Remote Data Transfer facility with optical communication media, with SAS Integration Scope , inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 26 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 200/1-1 Amps (33kV side) 27 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 300/1-1 Amps (11kV side) 28 Alumimium UG Cable- 33kV, 3Cx300 sq.mm XLPE insulated, Galvanised steel strips armoured power cable for feeders / Aux Tfr with necessarymetallic, non magnetic clamps atminimum 3 metre interval, steel/nylon cable tie wherever necessary 29 Outdoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPE Galvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 30 Indoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPEGalvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 31 Distribution Transformer 11kV/433V, 250 kVA, Star rated (BEE Latest notification as on date of tender)with 11kV & 433V outdoor cable entry box, suitableDistribution Box with LT cable (Trfr to LT box) with 500Amps Fuse and MCCB including all accessories like Busbar, Metering Cabinets etcand its fixing -mounting arrangement on plinth 32 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches and one Vacuum/SF6 breaker suitable for 11KV/433V Auxillary Transformer/ Outgoing feederas per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 33 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches as per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 34 Supply of 11kV indoor VCB 5 panel set with combinations of Incomer feeder panel with PT (1 number), Outgoing feeder panel (3 number) and transfomer panel (1 number) with bay control and protection unit (BCPU) for integration with upstream Substation Automation System (SAS) through HSR/PRP topology (IEC 61850 edt 2 compliant) with protection philosophy specified in technical specification along with supply of accessories necessary for operational spares and special tools (as per attached list clause 37.6 & 38 of volume 2, Chapter 30). Bus Bar ratings are 2000A. Circuit breaker shall be E2 M2 C2 class as per IEC 62271-200. Feeder, transformer and incomer panel shall have capacitive voltage indicators (CVI) and only incomer panel BPCU will have PT inputs. Feeder,transfomrer and incomer panels shall house one each multi-function meter (MFM) and DLMS compatible energy meters. Each Incoming and outgoing feeders shall be equipped with split core type CBCT for Sensitive Earth Fault Protection 35 Supply of Polymeric type LA suitable for 11kV 36 3Cx300sqmm 11kV Aluminium XLPE insulated under ground armoured cable, with necessaryclamps for fixing with support structure at 3 m interval 37 3Cx300sqmm11kV Aluminium XLPE Under ground cable Termination Kit Outdoor Heat Shrinkable 38 3Cx300mm2 11kV Aluminium XLPE Under ground cable Termination Kit Indoor Heat Shrinkable 39 Supply of Hot dip Galvanised LatticeStructurefor 33kV,11kV& 110 kV Switch Yard, Columns/Beams/Pre fabricated Cable Supports in Trenches/lightning mast structure/ lighting mast structure/ equipment structures unless otherwise not specified else where in the BOQ etcinclusive of N&Betc(as per respective Technical Specifications, standards and relevant special conditions). 40 EOT Crane of suitable capacity (minimum 5T safe working load) with single hook and double girder arrangement for GIS Hall. Contractor shall submit the capacity calculation of the crane incorporating 25% additional load considering erection and maintenance of largest GIS component / assembly. 41 DG set 125 kVA silent type, Outdoor plinth mounted withAMF panel, Auto Load Change over module and panels, Battery and its charger, Diesel Tank etc with SAS integration facilities including all accessories complete 42 Battery Set - 110 V, 400Ah , Lead Acid plante Battery SetC10 Duty cycle (Rating is tentative and final sizing as per the load calculation shall be under bidder scope) & Installationwith Battery Racks made with acid proof material ,two number of indsutrial type flame proof exhaust fan and all necessary arrangements including tool kit like hydro meter, chemical gloves, multimeter etc. 43 48V, 200 AH VRLA Battery Set with all associated accessories for reliable communication & data acquistion project complete as per specifications 44 SCADA compatible 110V Dual mode (FC+ BC) Battery Charger, with independent Float (FC)and Boost charging (BC) (2 number rectifier unit) min-FC-80A, BC-80A, suitable for 110V Battery bank as per design and shall charge Battery set as per technical requirement during float /boost mode without interruption to load. The charger shall have two independent incomer supply.(Battery charger shall meet the full DC load during boost condition and the Bidder shall propose the final sizing of the battery charger during detailed engineering for approval)(Both set shall be of different make ) 45 Battery Charger - 48 V Dual mode (FC+BC) (Float - 30A/Boost - 60A) - SCADA compatible, SMPS based,Suitable to VRLA Battery set and shall be able to charge Battery set as per requirement during float /boost mode as well as it shall supply to load as per rated voltage of load components inclusive of necessary power, communication and control cables with all accessories complete -Compact type 46 SCADA compatible DCDB-110 V with minimum 20 + 20 Outgoing feeders duplex type (Floor Mountable) with changeover panel having interlock facility with 20% spare feeder breakers for station control and protection systems as per the station requirement, facility shall be there to charge any battery set with any of the battery chargerwith interlock. Ratings shall be as per the battery sizing calculation. 47 DCDB 48 V with change over facility and min 20 Nos. of Distribution Outlets( 2 Nos.- 10A and 18 Nos. 6A)-DUPLEX Type-SCADA/SAS Compatible-Wall mountable 48 SCADA compatible LT 3 phase 50Hz Panel Boardwith Insulated Aluminium Bus Bar, 2 nos incomers (Auxillary Transformer / DG Set), automatic interlock/load change over facilty, two sets of outgoing,panel with LED indications, panel meters,ACB /MCCB(incomers), MCCB (feeders), Earth Bus bar etc., for LT Power Distribution to Control room/equipments including all accessories complete as perspecifications having minimum 20% spare feeders.Remote operation shall be possible for incomers and DG set.(Panel sizing and rating to be proposed by the bidder during detailed engineering for approval). 49 SCADA compatible LT MLDB/LDB/Street light control DB with Lighting Transformer, Surge Protection Devices, MCCB, MCB, RCCB, ELCB and all accessories complete as per technical specifications for Control Room and Yard lighting including all sub distribution boards, and SCADA compatible ACDB/Sub ACDB for Air Conditioners & AHU with soft starting feature etc. including MCCB, MCB, RCCB, ELCB. (The DB sizing and rating shall be proposed by the bidder, with 20% spare capacity, during detailed engineering for KSEBL approval) 50 SCADA compatible LT Emegency Lighting Distribution Board (ELDB) with 63A Incomer and minimum 12Nos 10A Outgoing Feeders and DC Emegency Lighting Distribution Board (DC ELDB) and related accessories including MCCB/MCB,RCCB/ ELCB as perstandard specifications for Emergency lighting in the substation / Switchyard, charges including all sub distribution boards 51 LT A.C Three Phase Self mounted Indoor Power Kiosk IP 42 with 1 incomer MCCB 63A including indicating lamps,single phase and three phaseindustrial type16A sockets etc. at GIS hall 52 LT A.C Three Phase Self mounted Outdoor Power Kiosk (IP 56) with 1 incomer MCCB 250A, 2 Outgoing MCCB 160A & 100A including indicating lamps,3 phase and singlephase industrial type 16A sockets etc. complete for Transformer oil filteration unit, welding purpose etc. 53 Supply of Protection Panels/Equipments, Substation Automation System and materials as per technical specifications, IS/IEC Standards applicable 54 Control and Protection panel for Transformer with Differential Protection,REF (Transformer management relay) for HV and LV [M1 and M2 relay shall be of different make / platform and each shall have-87, 67/67N, 64R-Low Impedance, Transformer Mechanical Protection- Bucholz, OLTC Bucholz, OLTCPanel Control & signal interfacing with RTCC panel, OTI, WTI, PRD1 &2 through high impedance tripping relays, MOLG Alarms etc.,] 33/110kV 60MVA, with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA system. Energy meters as per technical specifications and suitable for GIS switchgear modules 55 Busbar Protection panel for8 bays (110kV Bus) as per specifications -with zone segregated tripping, LBB, end zone protection, local HMI for displaying differential current, SLD, Isolator Position etc., with output tripping relays (drawout type) and provision for interface to SCADA/SAS system 56 Control and Protection panels (main 1 and 2- 87L,21,67/67N,50N,59,PSB, 79A/R,49,81 O/U) for 110kV Feeders with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA systemas per tech specifications and suitable for GIS switchgear modules (M1 and M2 relay shall be of different make / platform and the combination shall exactly suit with the remote end M1 and M2 relays). Over and above the normal Tri-Vector Meter, the contractor should supply SEM Meters as per SRLDC/PGCIL Standards, additionally. 57 Control and Protection panel for 110kV Bus Coupler with BCU and additional Common BCU for Auxiliary control System and Monitoring including the panel as per standard and requirement of 110kV GIS 58 Design, Manufacture and Supply of Complete SAS system for 110kV GIS , as per detailed technical specification , SAS system Architecture andSLD , Reduntant Servers, Reduntant Gateway, Reduntant Routers with Hardware Firewalls,2 Nos Operator Work Station with HMI -Desktop (one operating work station with extended HMI at Nedumkandam (10Km away)) , 2 Nos. Engineering Work Station(Lap top and Desk top) , one metering PC with DCU for SAMAST metering and Remote Station Controls, necessary Panels and Furnitures etc completewith all necessary accessories, cables,converters, GPS based Time Syncronising Unit IEC compatible to cater data to and from all bays and transformer, SCADA compatible panels,interfacing /intergating line differential relay in CR panel, SAS gateway server panel etc to FODP/Communication equipment in communication room as per specification, including supply of all necessary converters for interfacing with the communication equipment , unarmoured OF cable , 40mm PLBHDPE pipe duct , all interconnecting cables , Patch chords devices etc. complete. The scope include integrating 33kV and 11 kV systems.SAS Architecture should be suitable for plug and play integration of future bays. [Including mandatory Spares as specified in volume 2 - Technical Specfications, Chapter 11, Annexure C] 59 Design, Manufacture and Supply of materials / item for Power Cable, Control Cables and instrumentation cable, Supply of various sizes of 1.1 kV FRLS-0H PVC armoured copper cable for control , Aluminum/ Copper LT power cable as per approved cable schedule (to be prepared by contractor and got approved), and provision of all types of cables from Power and Auxilliary Transformer and other equipments/switchgears, for the substation (Aluminium cables of size 185 mm2 and above shall be XLPE type) includingties , tags etc. supply of suitable size PVC pipe and accessoriesfor drawing exposed cables as per the technical specifications, IS/IEC Standards applicable. 60 12x4mm2 Control CableCopper 61 4x6mm2 Control CableCopper 62 4x4mm2 Control Cable Copper 63 2x4mm2 Control Cable Copper 64 19x2.5mm2 Control CableCopper 65 12x2.5mm2 Control Cable Copper 66 7x2.5mm2 Control Cable Copper 67 4x2.5mm2 Control Cable Copper 68 3x2.5mm2 Control Cable Copper 69 2x2.5mm2 Control Cable Copper 70 2x1.5mm2 Control Cable Copper 71 4x0.5mm2 instrumentation Cable Copper 72 4x10mm2 PVC InsulatedLT copper cables 73 2x10mm2 PVC Insulated LT copper cables 74 2x1.5 sq.mm or higher size PVC Insulated shielded copper cables for Transformer OTI & WTI wiring 75 20/25 mm dia FRLS PVC Rigid/Flexible Conduit including all clamps, clips etc. for Fire Alarm Panel and sensor wiring purpose 76 3 1/2C x300 Sqmm 1.1kV LTXLPE insulated armoured Aluminium cable 77 3 1/2C x 240 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 78 3 1/2C x 120 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 79 3 1/2C x 90 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 80 3 1/2C x 70 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 81 3 1/2C x 50 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 82 3 1/2C x 35 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 83 3 1/2C x 25 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 84 4C x 16 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 85 1x 95 sqmm DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 86 1x 70 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 87 1x35 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 88 Supplying aluminium cable tags with punching number and alphabets up to 7 digits or higher as per requirement for 220/33/11kV power cables including cost of all materials as per the technical and standard specifications 89 Hot dip galvanized ladder type cable tray with joint plate and N&B size300x100x2 with all accessories complete 90 Hot dip galvanized ladder type cable tray with joint plate and N&B size 450x100x2and with all accessories complete 91 Hot dip galvanized ladder type cable tray with joint plate and N&B size600x100x2 and with all accessories complete 92 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Conductor/ Earthing Materials and associated materials for Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable 93 Aluminium Bus bar 120*10mm 94 ACSR Wolf Conductor 95 110 kV 90kN Silicon Composite Longrod Insulator 96 110 kV 70kN Silicon Composite Longrod Insulator 97 110 kV Single Tension H/W and Accessories suitable for Single Wolf 98 110 kV Single Suspension H/W and Accessories suitable for Single Wolf 99 wedge – connector suitale for wolf/Kundah 100 wedge with paddlesuitale for wolf/Kundah 101 Earth Wire 7/3.15 mm Galvanised Steel wire with required hardwares accessories and earthbond 102 Tension Clamp and Tail Clamp for 7/3.15 mm Earth Wire 103 32/40mm MS rod for earthing 104 GI strip all sizes as per requirement for earthing 105 Clamp and saddle for GI strip/wire 106 Test link for lightning protection 107 1.5m GI lightning spike with fixing clamps 108 Design and supply ofVentilation system for GIS hall(positive pressure type)with prefilters and fine filters of washable type for 100% capacity of GIS hall, with air displacement of 5 times the volume of GIS hall per hour (one operating + one standby , consisting of two units each having capacity 5 times air changes per hourof GIS hall workingcyclically for 50% of time)with soft starting feature,comprising of GI ducts( with provision for nitrile rubber insulation if taken externally), fire dampers, exhaust dampers, grills, noise reduction system etc. complete.The system shall be monitored via SCADA including necessaryelectrical panels. 109 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Fire and Safety Equipments and materials for 33/110kV Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable- Portable and wheel/ trolley mounted fire extinguishers for Control room 110kV GIS Hall, 110kV Switchyard Relay panel room of GIS Hall,Transformers and other Strategic locations including its installation at site 110 Dry chemical powder of 9kg capacity 111 Dry chemical powder of 25kg capacity 112 Dry chemical powder of 50kg capacity 113 CO2 gas type of capacity 6.5kg 114 CO2 gas type of capacity 22.5kg 115 Mechanical foam type capacity 9LT 116 Mechanical foam type capacity 50LT - 117 Fire Stand with 4 buckets(Including Concreting as per drawings) 118 SCADA compatible - Main Fire Alarm Control Panel (Zone of protection as per approved scheme) complete with Charger, Rectifier, Visual Display, battery back up complete as per the station requirement 119 Photo Electric type Smoke detector with base compatable for Fire Alarm Panel 120 Photo Electric type Heat detector with base compatable for Fire Alarm Panel 121 Supply of Beam Detector and Reflector for GIS with base compatable for Fire Alarm Panel 122 Audio Alarm with Hooters cum Speakers compatable for Fire Alarm Panel 123 Manual Call point of Break Glass Type with hammer and chain 124 Insulating Mat (Size 2000x1000x2mm) class A including its fixing at site as per Technical Specification and IS 125 Safety Chart for First Aid, Electric Shock & Fire and Fire Fighting Equipments including its fixing accessories complete 126 Lighting and General / Miscellaneous Items 127 Optical Fibre Cable (12F Single Mode and 12F Multimode) , SM and MM Patchcords, all necessary connectors complete, as per site requirement for extended HMI, bus bar protection other than SASas per site requirement and technical specification 128 Ground Enhancement Material (GEM) ( Per Bag -11.33 Kgs ) - Conforms IEC 62561-7 Standard. The GEM shall have Resistivity of less than 20 Ohm-cm and Environmental friendly 129 Visual Monitoring System (VMS) with surveilliancecamera as per technical specification and layout drawing (Including local PC monitoring set up having sufficient storage capacity, remote end PC monitoring if necessary set up shall be in the scope of supply) including necessary power and communicationcables, interconnecting hardwares, PVC pipes and all other accessoriesetc complete as per the technical specifications (minimum requirement : Fixed Camera : min 8 Nos, Pan Tilt Zoom Camera : min 2 Nos, Fixed Variable Focus: min 4 Nosand storage >8TB) 130 Design of Air Conditioning system and Supply of5 Star rated (as per latest BEE notification)2TR or higher capacity split type inverter Air Conditioners, with stabilizer, Power Isolator etc.for Control & Relay panel room, Communication room, SCADA room, Bay Control Room (each room has got minimum one unit of redundancy, cyclically operated with Room temperature indicator) as per detailed engineering and approval. Temperature indicators shall be integrated to SCADA 131 SPARES for GIS - 220/110kV 132 Tripping & closing coil(Each Breaker type Module) 133 Motor for disconnector of each type of equipment 134 Motor for CB spring charging (each Breaker Type) 135 SF6 Pressure Guage for Circuit Breaker 136 SF6 Pressure Guage for other compartments 137 SF6 Pressure Relief Device 138 Auxillary contact assembly for Circuit Breaker 139 Auxillary contact assembly for Disconnector/Isolator-each type 140 SF6 gas 141 Moisture absorbant catridge 142 NRV gas filling valve for equipment 143 Indication lamps and lamps for semaphores & annunciators- one for each type & colour 144 Annunciator full set each type with one set of relay card 145 Special tools for Installation and Maintenance -220/110kV 146 Gas Leakage detector - DILO make 147 Special spanners for General maintenance for supplied GIS 148 SF6 gas bottle locking , measuring and filling assembly with whole hose 149 Measuring Instruments 150 Clamp on meter- capable to measure mA range .• High sensitivity, miniature AC/DC clamp meter.Range: 200mA/2/20A AC, 2/20A DCMin. resolution for AC: 0.1mAMin. Resolution for DC: 1mAJaw size: 7.5mm all required accessories from following make and model Fluke,MEGGER,KYORITSU 151 Phase Sequence meter with Standard accessories -Fluke,MEGGER,KYORITSU 152 Digital Multimeter 279FC TRMS Thermal or advancedFluke,MEGGER Model 153 Analog Multimeter, with Standard accessories - Fluke,MEGGER,KYORITSU 154 SF6 gas Analyser including DEW point,purtity & Hygrometer etc.
Contract Date: Apr 01, 2026 Contract Value : 369.42 Crore
Boards / Undertakings / PSU No of Bidders 8
20.
Defence #9843674 AOC
Maintenance Repair And Replacement Of Defective Items Of Ht Distribution System At 9 Brd Af Stn Pune Under Ge (Af) Lohegaon - Supplying laying & testingof XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 185 sq mmcomplete all as specified and directed by Engr-in-Charge. 2 Supplying laying & testingof XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 120 sq mmcomplete all as specified and directed by Engr-in-Charge. 3 Supplying laying & testingof XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 sq mmcomplete all as specified and directed by Engr-in-Charge. 4 Taking down old unserviceable HT cable 11 KVof any size from trench / pole complete all as specified and directed by Engr-in-Charge. 5 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etccomplete all as specified and directed by Engr-in-Charge. 6 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soilcomplete all as specified and directed by Engr-in-Charge. 7 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rockcomplete all as specified and directed by Engr-in-Charge. 8 All as per Srl Item no. 5 above but for depth exc 1.5 metres but n.exc 3 mtr and getting out in Hard rock by chiselling complete all as specified and directed by Engr-in-Charge 9 Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soilcomplete all as specified and directed by Engr-in-Charge. 10 Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting pointcomplete all as specified and directed by Engr-in-Charge. 11 M&L for crushed stone sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed by Engr-in-Charge. 12 Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cablecomplete all as specified and directed by Engr-in-Charge. 13 Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes100 mm diacomplete all as specified and directed by Engr-in-Charge. 14 M&L for Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM refilling, well ramming in layers with watering afterlaying of RCC /GI pipe under road making good with PCC 1:2:4in all respectto match with the existing surface all as directed by E-in-charge. 15 S&F in repairscable end jointing kit 95Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, incl carrying out 5KV megger test after jointing complete all as specified and directed by Engr-in-Charge. 16 S&F in repairscable end jointing kit120to 185 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor typecompleteincl carrying out 5KV megger test after jointing all as specified and directed by Engr-in-Charge. 17 S&F in repairscable straight through joint 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work completeincl carrying out 5KV megger test after jointingall as specified and directed by Engr-in-Charge. 18 S&F in repairscable straight through joint 120to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable completeincluding necessary excavation and earth workcompleteincl carrying out 5KV megger test after jointingall as specified and directed by Engr-in-Charge. 19 S&F in repairscable end joint185 Sqmm 3 core XLPE 22 kV HT Cable heat shrinkable indoor / outdoor typecompleteincl carrying out 5KV megger test after jointingall as specified and directed by Engr-in-Charge. 20 S&F in repairscable end joint300/400 Sqmm 3 core XLPE 22 kV HT Cable heat shrinkable indoor / outdoor typecompleteincl carrying out 5KV megger test after jointingall as specified and directed by Engr-in-Charge. 21 M&L for services for cable fault location for 11 kV / 22 KV 3core XLPE Cablewith the help of 22kV HT fault detector machinecomplete all as specified and directed by Engr-in-Charge. Note: Contractor shall depute his staff along with fault locating machine within 6 hours of intimation. 22 Taking out the HT 11 KV metalclad Vaccum circuit breaker of rating 400/630A, 11000 volts,3 ph, 50 Hz, 250 MVA ofany make and type from the cubical panel, for repairs/overhauling and servicingincluding replacement of wornout parts comprising the following works.(a) Removing the complete fixed contacts, moving contacts, cleaninig the contacts,removing the fittings and fixing back to the breakers after adjusting the pressure(b) Checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation(c) check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc(d) checking, setting of the movement of the trolly of breaker lubricate it adjust the stopper bolt/lever for proper functioning of the breaker(e) check the auxilliary switch, shunt trip assembly, closing / Trip solenoid, limit switch and complete contol wiring of the breaker and repair the same for effective functioning of the breaker(f)Testing of IR value with the help of meggar and commissioning the HT vaccum circuit breaker all as specified and as directed by Engr-in-chargeNote:- VCB spares shall be measured and paid seperatly underrelevent itemof Sch A as a Supply only. However other than mentioned spares in this schedule if required for smooth functioning of VCB, cost of the spares deemed to be included in quoted rates complete all as specified and directed by Engineer-in-Charge 23 Supply only moving contact to the vacuum circuit breaker of existing rating , 3 phase, 11000 volts,complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 24 Supply only fixed contact to the vacuum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 25 Supply only Arc shield to the vacuum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge(all as per exsisting make and type) 26 Supply only spring charging motor to the vacuum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 27 Supply only auxiliary switchto the vaccum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge. (all as per exsisting make and type) 28 Supply only latch switch assembly to the vaccum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 29 Supply only closing soleniod coil to the vacuum circuit breaker of existing rating , 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 30 Supply onlyloading spring to the vacuum circuit breaker of existing rating, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type) 31 Supply only HVX-X VCB body Housing suitable for 11 KV Scnieder make VCB 3 phase complete as per existing sample. 32 M&L for servicing and testing of secondary injection of over current and earth fault relay of HT VCB 11 kV panel on each multiple setting , readjustment and calibration the same complete, checking of control wiring including testing on completion complete all as specified and directed by Engr-in-Charge. 33 M&L for servicing and testing of primary injection by artificial loadthrough CTs on each multiple setting of over current and earth fault relay of HT OCB 11 kV, testing CTs polarities , relay calibration, cordination of relays completeand checking of control wiring including testing on completioncomplete all as specified and directed by Engr-in-Charge. 34 S&F in repairs neon indication lamps assembled for HT 11 KV cubicalcomplete all as specified and directed by Engr-in-Charge. 35 M&Lfor replacement of HT voltmeter digital type 0 to 15 KV (PTR 11 KV/ 110 Volt) ,complete all as specified and directed by Engr-in-Charge. (As per existing) 36 M&Lfo replacement of HT Ammeter Digital type 0 to 60 Amps. complete all as specified and directed by Engr-in-Charge.(As per existing). 37 M& L for replacement of defective current transformer resin casted two core double ratio ( one for protection and other core for metering equipment), class 1.0, 100Amps, as per existing CT ratio and model, for 11 kV of VCB complete all as specified and directed by Engr-in-Charge. 38 M&L for replacement of unserviceable HRC cartige fuse of existing capacity make suitable for HT VCB 11 kV complete all as specified and directed by Engr-in-Charge.of Crompton/MEI make all as directed. 39 Taking out old unservicable battery back up from HT 11 kV OCB/VCB panel, S & Fix new batterry back up with maintenance free sealed lead Acid Battery suitable size complete as per exsisting or equivalent model and testingcomplete all as specified and directed by Engr-in-Charge. 40 M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and directed by Engr-in-Charge.Note: (a) Oil topping up shall be measured and paid separately.(b) Filtration shall be done at site and on line.(c)BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge(d) Dielectric strength of the oil shall not be less than 50 kV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved complete all as specified and directed by Engineer in Charge 41 SupplyandFill new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI certified of approved makecomplete all as specified and directed by Engr-in-Charge.Note:(a)The transformer oil shall be ISI certified, and brought at site in sealed container only.(b)Cost of collection of samples before and after topping up/changing including testing for dielectric strength etc complete included in the rate quoted for this item 42 Disconnecting the transformer any type situated at various locations11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding.Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enameled wire / copper strip of exsisting size, providing new insulation, sleeves for outlet connections, heating the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning.The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer 150 to 350 KVANote:(i)Copper winding wire/strip will be measured and paid separately.(ii) Transformer oil for topping up will be measured and paid separately.(iii) Transportation of transformer for repair and re-installationis deemed to include in quoted rates complete all as specified and directed by Engineer in Charge 43 Disconnecting the transformer any type situated at various locations11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding.Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire / copper strip of exsisting size, providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning.The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer above 350 KVA to 500 KVANotes(i)Copper winding wire/strip will be measured and paid separately.(ii) Transformer oil for topping up will be measured and paid separately.(iii) Transportation of transformer for repair and re-installationis deemed to include in quoted rates complete all as specified and directed by Engineer in Charge 44 Removal of burnt HT coil winding and replacement of the same with new copper wire coil of same gauge and turns including necessary insulation materialslike impregnated paper or super enamelled of transformers of capacity 150 KVA to 500 KVA complete all as specified and directed by Engineer in Charge 45 Removal of burnt LT coil winding and replacement of the same with copper strips of same gauge and turns including necessary insulation materials of transformers of capacity 150 KVA to 500 KVA complete all as specified and directed by Engineer in Charge 46 Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifyingthe leakage by replacing the unserviceable spare parts of capacity 50 to 750 kVA transformerand complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system complete all as specified and directed by Engr-in-Charge.Note:- Defective parts replaced will be measured and paid separately 47 Supply and fix in repair of LT bushings of transformer upto 750KVA, 11/.433 KV rating with brass studs complete all as specified and directed by Engr-in-Charge 48 Supply and fix in repair of top cover gasket set of transformer upto 750KVA, 11/.433 KV rating complete all as specified and directed by Engr-in-Charge 49 Supply and fix in repair of radiator flanged gasket 6mm thick of transformer upto 750KVA, 11/.433 KV ratingcomplete all as specified and directed by Engr-in-Charge. 50 Supply and fix in repair of oil level indicator gasket set complete all as specified and directed by Engr-in-Charge 51 Supply and fix in repair of HT bushing with brass studs 11KV of transformer upto 750KVA, 11/.433 KV rating complete all as specified and directed by Engr-in-Charge. 52 Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformercomplete all as specified and directed by Engr-in-Charge. 53 All as per Srl Item No 52.00 above but suitable for transformer 1500 KVA to 2500 KV 22KV/11KV 54 Supply and fixin repair of HT 11 KV terminal rod of suitable size for the transformer of50KVA to 315 KVA ratingcomplete all as specified and directed by Engr-in-Charge. 55 Supply and fixin repair of HT 11 KV terminal rod of suitable size for the transformer of 400KVA to 650KVAcomplete all as specified and directed by Engr-in-Charge. 56 Material and labour for painting of the transformer (50 to 150 KVA) complete by removing old paint by scrapping and providing spray painting with synthetic enamel paint of approved make duly marking/writing MES/SM No.complete all as specified and directed by Engr-in-Charge. 57 Material and labour for painting of the transformer (150 to 350 KVA) complete by removing old paint by scrapping and providing spray painting with synthetic enamel paint of approved make duly marking/writing MES/SM No.complete all as specified and directed by Engr-in-Charge. 58 Material and labour for painting of the tranformer (350 to 500 KVA) complete by removing old paint by scrapping and providing spray paiting with synthetic enamel paint of approved make duly marking/writing MES/SM No complete all as specified and directed by Engr-in-Charge. 59 Material and labour for painting of the power tranformer (1500 to 2500 KVA) complete by removing old paint by scrapping and providing spray paiting with synthetic enamel paint of approved make duly marking/writing MES/SM No complete all as specified and directed by Engr-in-Charge. 60 M&L for dismantling of air break gang operated switches/drop out fuse units vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed by Engr-in-Charge. 61 Supply and fixing in repairs of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground levelincluding GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangementscomplete all as specified and directed by Engr-in-Charge.. 62 Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories etc, including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge. 63 Supply, fixing and connecting in repairs HT 11 KV outdoor expulsion type lightning arrestors with mounting accessories complete fixed on cross arms of 2 pole structur and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed by Engr-in-Charge 64 S& F of epoxy insulator suitable for 11 KV VCB or 11 KV feeder pilar box bus bar support complete as per existing size and including taking down old unsv complete all as directed by Engr-In-charge. 65 S&F in repair disc insulator porcelain vitreous brown 145mm high and 255 mm dia ball and socket type two in series assemblywith castaluminium 4 U bolttension hardeare and tension clamps for conductors working pressure HT 22 KV complete all as specified and directed by Engr-in-Charge. 66 S&F for aluminium tubing heavy duty of size 32mm outer dia, 20mm inner dia, 06 mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed. 67 S&F for aluminium strip of size 32mm x 10mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators with jumpers including removal of unserviceable one complete all as specified and directed. 68 M&L for cement concrete(1:4:8) type D2 in foundation filing and mass concrete using 40 mm graded stone aggregate for pole/ path way foundation or as required on site etc complete all as specified and directed by Engr-in-Charge. 69 M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40 mm graded stone agg forpole/ path way foundation or as required on site complete all as specified and directed by Engr-in-Charge. 70 M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone agg etc complete all as specified and directed by Engr-in-Charge. 71 Materials and labour for cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint/Emulson over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge. 72 M&L for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in groungd vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 3 of SSR Part-1 of 2009.00 and as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of40 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in-Charge. 73 Taking down old PT and supply & Fix 11 KV single phase in door resin cast PT of ratio 11 KV/rt 3/110V/rt 3/110V/rt 3 Class 1, Burden 100 VA,insulation level 100 KV, voltage factor1.2 Cont and 1.9 for 30 Sec, conforming to IS-3156 completeall as specified and directed by Engr-in-charge. 74 S&F in repair numerical type 3 over current earth fault relay , front USB Communication, 3 relay outputs, fault records-10, fixed design, non-draw out 1A/5Acomplete all as specified and directed by Engr-in-charge. 75 S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge. 76 S&F Danger sign board sticker suitable for 11000 volts of size 300x300 mm with letters, figures and conventional skull and bones in signal red colour and fix on HT feeder pillar box/Panel complete all as specified and directed by Engr-in-charge. 77 Material and labour for painting to existing HT 2 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint ,complete all as specified and directed by Engr-in-charge. 78 Material and labour for painting to existing HT 4 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge. 79 Material & Labour forpainting to HT feeder pillar boxpanel & duct coveretc, including angle iron frame with two coat of fire red synthetic enamel paint including door welding with hingecomplete all as specified and directed by Engr-in-Charge. 80 M&L for cleaning of out door sub station/ HT feeder pillar box/ two/four/six pole structure by cutting and removing vegetation growth and surface leveling and removing debris and depositing to a distance not more than 50 mtrcomplete all as specified and directed by Engr-in-Charge. Note : Cleaning of Area may measured and paid more than one time in contract period as required as required on site. 81 Taking out the HT 22 KV metalclad Vaccum circuit breaker of capacity 400A, 22000 volts,3 ph, 50 Hz, offrom the cubical panel, for repairs/overhauling and servcingincluding replacement of wounout parts comprising the following works.;-(a) Removing the complete fixed contacts, moving contacts, cleaninig the contacts,removing the fittings and fixing back to the breakers after adjusting the pressure (b) Checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation (c) check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc (d) checking, setting of the movement of the trolly of breaker lubricate it adjust the stopper bolt/lever for proper functioning of the breaker (e) check the auxilliary switch, shunt trip assembly, closing / Trip solenoid, limit switch and complete contol wiring of the breaker and repair the same for effective functioning of the breaker (f) Testing of IR value with the help of meggar and commissioning the HT vaccum circuit breaker all as specified and as directed by Engr-in-charge Note:- VCB spares shall be measured and paid seperatly underrelevent item. However other than mentioned spares in this schedule if required for smooth functioning of VCB, cost of the spares deemed to be included in quoted rates. 82 Supply only the following parts to the vaccum circuit breaker of cap 400A , 3 phase, 22000 volts, 250 MVA all as per exsisting make and type 83 Moving contact 84 fixed contact 85 Arc Shield 86 Charging motor 87 Auxiliary switch 88 latch switch assly 89 Closing soleniod 90 loading Spring 91 Over hauling and testing of secondary injection of over current and earth fault relay of HT VCB 22 KV panel on each multiple setting , readjustment and calibration the same complete, checking of control wiring including testing on completion all as specified . 92 Overhauling and testing of primary injection by artificial loadthrough CTs on each multiple setting of over current and earth fault relay of HT VCB 22 kV, testing CTs polarities, relay calibration, cordination of relays completeand checking of control wiring including testing on complitionall as specified 93 M&L for replacement of unserviceable HRC cartige fuse of existing capacity make suitable for HT VCB 22 KV of Crompton/MEI make all as directed. 94 M&L for Repair/maint of NGR for 22/11 KV transformer complete with replacing burnt out parts such as insulators, washer, resistence coil etc and all coonected items complete testing and all as directed by engr-in-charge. 95 Supply and fix in replacement of old/unserviceable male contact/moving contacts blades for GOD switch 400 Amp 11KV ,complete all as specified and directed by Engr-in-charge. 96 Supply and fix in replacement of old/unserviceable female/fix contact jaw for GOD swtich 11KV 400Amp ,complete all as specified and directed by Engr-in-charge. 97 Supply andloose filling stone Aggregateof gauge40 to 80 mm grade in Two pole/4 pole electrical sub stnarea, complete all as specified and directed by Engr-in-charge. 98 M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/piope or fixed to poles or any other indicated situation for loop earting etc as required 32x6 mm galvanised iron strip , complete all as specified and directed by Engr-in-charge. 99 S&F cable joint straight through185 Sqmm 3 core XLPE 22 kV HT Cable heat shrinkable complete all as specified and directed by Engr-in-Charge. 100 M& L for mouisture proof painting using anti tracking paint insideHT 11/22 KV breakers incl CT / PT chamber etc in any kind of HT Breakercomplete all as specified and directed by Engr-in-charge 101 S & Ftesting and commissioning 22 KV Spout bushing complete all as specified and directed by Engr-in-charge 102 S & F bus bar sleaves suitable for HTbreakers 22/11 KVbreaker bus barcomplete all as specified and directed by Engr-in-charge 103 S & fillinggood quality silcagel suitable for HT 22/11 KV Transformers breathersas required on sitecomplete all as specified and directed. 104 Machinary and labour forservices to remove mouisture from cables/ breakers by applyinghighpot testing for 11 kV / 22 KV 3core XLPE Cable 95 sqmm to 185 sqmmcables /breakers as required on site with the help of 22kV / 11 KV HThighpot testing machinecomplete all as specified and directed by Engr-in-Charge. 105 Taking out carefully old serviceable HT UG cable 11 KVof any size from trench / pole /cable duct etc as required on siteand rerouting asrequired on site at sub stn complete all as specified and directed by Engr-in-Charge. Note : Earth work shall be measured and paid seprately under respective item 106 S& F of room heater 1200 watt, with 3 no 400 watt heating element halogen type, plastic body with 15 amp plug top including earthing lead and 3 modes of operation ,complete all as specified and directed by Engr-in-charge. 107 Taking proper shutdown of HT feederfrom concerning power housechecking, testing and locating faults of HT OH line/ under ground cable includingfour / two pole structure, HT feeder pillars etc. Opening/ disconnrcting HT electric connectios, removal of old jumpers by cutting of old rusted nuts,bolts & washers etc .Repair/ maint of HT GODs onfour/ two pole stucture by providing new lugs of suitable size including new nuts ,bolts & washers etc. Repair to operating mechanism of 11 KV air break gang operating capacity 200/400 Amps with necessary oiling/greasing to moving parts and to set right the alignment of Male/Female contacts for proper working, heating of HT feeder pillar for demoisturising the HT end joints, bus bar and epoxy insulators includingmaking HTfeeder serviceable as and when required completeall as specified and directed by Engineer-in-Charge. 108 Takingout/dismantling carefullyHT 11 KV VCB/OCB any type at oldand shifting within the sub stn and installation ,testing for smoth fuctioning in all respectcomplete all as directed by Engr-in-Charge. 109 S & FHT breaker heaterand thermostate 230 V suitable for 11 /22 KV HT VCB/OCB breaker incl wiring etc ,complete all as specified and directed by Engr-in-charge. 110 Supply and fixing in replacement of gang operated air break switches HT 22 KV grade outdoor type, triple pole of capacity 400 Amps rating mounted on polymer based 18 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground levelincluding GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangementscomplete all as specified and directed by Engr-in-Charge.. 111 Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, Triple pole, mounted on polymer based insulators for 22 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 100 Amps and connected with suitable size ofconductor as jumper between GOD and DO fuse, with 22 KV HT PVC sleeve, with all fittings/accessories etc, including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge.
Contract Date: Mar 20, 2026 Contract Value : 7.58 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
22.
Tourism #9760567 AOC
Tender For Gitanjali Restaurant At Konark Puri-2 Dismantling brick or stone masonry in lime or cement mortar under 3m height including stacking the useful materials for reuse and removing the debris within 50m lead.etc.as per the direction of Engineer-in-charge. 3 Dismantling & removing doors,window & ventilatots including removal of frame ,hinges ,fastening & stacking the same for reuse & removing the debris within 50m lead etc.as per the direction of Engineer-in-charge. 4 Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead etc.as per the direction of Engineer-in-charge. 5 Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep and stacking the useful materials for reuse and removing the debris within 50m lead etc as per the direction of Engineer-in-charge. 6 Removing old lime or cement plaster from walls including raking out joints 12mm deep and removing the debris within 50m lead etc as per the direction of Engineer-in-charge. 7 Dismantling and removing 2.5cm thick grading concrete from roof slab, cleaning the surface, lowering and removing the debris within 50m lead etc as per the direction of Engineer-in-charge. 8 Dismantling and removing lime concrete flooring 7.5cm to 10cm thick including stacking the useful materials for reuse and removing the debris within 50m lead etc as per the direction of Engineer-in-charge. 9 Providing scraping old paints with scrapers, sand papering and washing with soap water or soda including scaffolding, materials labour etc complete as per direction of Engineer-in-charge. 10 Providing & layingPlain Cement concrete (PCC )of proportion (1:2:4) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with all labour, cess and T&P required for the work etc. complete in all respect as per direction of Engineer-in-charge 11 Providing 16mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with Portlandslag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and , cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer-in-Charge. 12 Providing 12mm thick C.P. 1:6 finished even and smooth onmasonry wallsincluding racking out joints, scrapping and cleaning the surfaceand finishing the plastered surface smooth toproper plumbs and levels and providing grooves as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, royalty, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. 13 Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. 14 Providingfitting, laying and fixing ofvitrified tile flooring usingColour printed tiles having thickness of 6.5mm to 6.7mm conforming to IS 13756 of 1200mmx600mm special plane / printed series of approved qualityofMatt digital with slip shield Grande Matika Beige Light SS of Somany or equivalenthaving base price of the tileRs. 80 -90 / sqft in all floors on 25mm thick cement and sand mortar in ( 1:4) and joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing , watering and curing etc including cost conveyance taxes of all materials and cost, conveyance,taxes of all labour with T&P required etc. complete in all respects as per direction of Engineer-in-Charge. 15 Providingfitting, laying and fixing ofvitrified tile flooring usingColour printed tiles having thickness of 6.5mm to 6.7mm conforming to IS 13756 of 600mmx600mm special plane / printed series of approved qualityofMatt digital Moroccan Tiznit Bianco of Somany or equivalenthaving base price of the tileRs. 80 -90 / sqft in all floors on 25mm thick cement and sand mortar in ( 1:4) and joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing , watering and curing etc including cost conveyance taxes of all materials and cost, conveyance,taxes of all labour with T&P required etc. complete in all respects as per direction of Engineer-in-Charge. 16 Providing 1200mmx600mm size special plain/printed seriesedge cut vitrified wall tilesof premium grade of approved make having thickness 6.5mm to 6.7mm of approved qualityof Digital FP Grande Favara Crema FP of Somany or equivalenthaving base price of the tileRs. 80 -90 / sqft in all floor approved make & shade in Dadoes over 12mm thick cement plaster 1:3 (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the tiles including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge 17 Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. 18 Providing Granite stone prepolished 20mm thick in dadoof approved quality, colour and size in dado,riser of steps anddado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3)with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the worketc. complete in all respect as per specification and direction of Engineer-in-charge. 19 Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. 20 Providing 20mm thick of above 0.40 Sqm Kota Stone tile flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. 21 Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier under and all-around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, surrounding of pipes and conduits etc. complete (plinth area of the building at GROUND FLOOR only shall be measured) as per drawing, design and direction of Engineer-in-charge. (Chloropyrifos emulsifiable concentrate 1.0%) 22 Finishing wall surface with acrylic wall putty (water based) of approved make and finished smooth on even surface to receive painting including cost of scaffolding staging charges with cost of all materials, taxes with labour etc. complete as per direction of Engineer-in-charge. 23 Providing and painting two coats with plastic emulsion paint of(Nerolac/ Asian/ Berger/ Dulox or equivalent make) approved quality and approved shade over coat of primer of approved quality in all floors at all height by making the surface to the interior plastered surface over a coat primer with water bond cement primer of approved quality including cost, conveyance, loading and unloading of all materials, cost of all labour, sundries, T & P, scaffolding etc. required for the work and complete in all respect as per specification and direction of Engineer-in-charge. 24 Painting to external surface of building with two coats of weather seal coat of approved shade over coat of primer and quality of approved designafter cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. 25 Providing and painting two coats with synthetic enamel paint of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and , cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. 26 Providing & fixing factory made uPVC white colour sliding glazed window three track three panels sliding window wiyh fly proof SS wire mesh(two nos.glazed& one no. wire mesh panels) made of small series frame 92x44mm sash 32x60mm both having wall thickness of 1.9(+,-)0.2mm & single glazing bead of appropriate dimension etc complete as per direction of EIC. 27 Providing & fixing factory made uPVC white colour sliding glazed window two track two panels sliding window made of big series frame 67x50mm sash 46x62mm both having wall thickness of 2.3(+,-)0.2mm & single glazing bead/double glazing bead of appropriate dimension etc complete as per direction of EIC. 28 Fixed window/ventilators made of frame 47x50mm mullion 47x68mm both having wall thickness of 19(+/-)0.2mm & single glazing bead of appropriate dimension.(Area upto 0.75 sqm) 29 Supplying, fitting and fixing of G.I. grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / G.I. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircaseand parapet railingssquare bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) 30 Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. 31 Providing ,fitting and fixing of Iron work wrought and put up in trusses Steel Struss (With M.S. Pipe) with supporting,straps,jointing materials etc including cost of all materias , labour and machinaries, T&P etc.complete in all respect. 32 Providing ,fitting and fixing of plain formed TATA BLUESCOPE standard back coat coloured in standard length at 3000mmwith supporting,straps,jointing materials etc including cost of all materias , labour and machinaries, T&P etc.complete in all respect. 33 Supplying , fitting and Fixing of Stainless steelof 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel square pipe bracing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification , buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P, etc. required for the complete in all respects. 34 Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred(total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. 35 Providing and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 /Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakagePotlife @ 25°C 2 hours &@ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L 36 BOUNDARY WALL 37 Cleaning and grubbing road land including uprooting trees rank vegetation, grass,bushes , shrubs, saplings and girth up to300mm,revoval of stumpsof trees cut earlier and disposal of unservicable materials and stacking of servicable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm in thickness. 38 Earthwork in excavation in all kinds of soil upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, DI rocks etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. 39 Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). 40 Providing and laying plain cement concrete of proportion (1:4:8) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. 41 Single under reamed pile of 300mm dia & 6m depth foundation with RCC M25 using 12mm size black hard granite (Crusher broken) stone chips including cost of boring but excluding cost of M.S./Tor steel and labour charges for cutting, bending and binding of steel. Single under ream pile 42 For each Excess / less depth of 0.5m from the initial depth of 6.0m Add / deduct form the rate 43 Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. 44 Foundation 45 Plinth Beam 46 Columns 47 Lintel 48 Slab 49 Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. 50 Providing Brick work with Fly ashbricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 withdimensional tolerance +/ - 2percent in cement mortar ( 1 cement: 6 sand), for foundation & plinth with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour,conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge. 51 Providing Brick work with Fly ashbricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 withdimensional tolerance +/ - 2percent in cement mortar ( 1 cement: 6 sand), for superstructure with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour,conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge. 52 Providing 12mm thick C.P. 1:6 finished even and smooth onmasonry wallsincluding racking out joints, scrapping and cleaning the surfaceand finishing the plastered surface smooth toproper plumbs and levels and providing grooves as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, royalty, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. 53 Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royaltiesof all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. 54 Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. 55 Painting to external surface of building with two coats of weather seal coat of approved shade over coat of primer and quality of approved designafter cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. 56 INTERIORWORK 57 Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. complete.As per instruction of EIC(Rate as per SOR-2022) 58 Providing fitting and fixing of Gypsum false ceilling with Aluminium anodised T Section No. 3215 with 2-0 center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2-0x2-0 suspended from ceiling etc complete.As per instruction of EIC 59 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. Reffered from (DAR 2023 Volume II item no- 26.22.1 page no 2000) 60 Supplying and fixing of Door paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c and fixing of 9mm thick BWR ply with 4mm thick veneer pasting finished with melamine polishing complete.(Rate as per SOR-2022) 61 Supply and installation(including Labour) of premoulded plaster of pariscornice of 100mm depthonroof corner of the room with complete finish (Excluding painting) as per the direction of Engineer-in-charge. 62 Supplying and fixing of Wall papervinyl coated ,paper based ,textured , embossed wth thickness 0 .3 mm min. of approved design fixed with adhesive over wall surface finished with putty and primer including cost of all material and labour etc. Complete as per the direction of Engineer-in-charge. 63 Providing & laying of tile carpet 50 x 50cm made of PET of reputed brand such as (Heritage/ SKIPPER or equivalent) of pile height of 5mm with pvc backing, having density of 2800 g/m, of approved design/shade with sound observation properties. Rate includes complete installation with backing foam, necessary adhesive etc. including the cost of all materials, cost of all labour, conveyance, loading & unloading, and T&P, etc. complete in all respect as per direction of the Engineer in Charge 64 Providing and fixing up of window curtain in required sizes having the curtain cloth fabric material: 100% Polyester, 200-300 gsm, Assorted colours plain and prints, Beige, cream, light brown, light colour with soft and smooth textured, good drapabilityof approved brands (SKIPPER / PALLETTE or equivalent), semi blackout to full blackoutincludingfixing hardwares - ceiling mounted curtain tracksof approved brands( MARVEL , JINDAL or equivalent) including ring, hooks all complete. Sheer curtain fabric of density 60 -100 gsm, of white colour with separate track including all fixing hardwareas per the instruction of Engineer in charge. 65 Supply & laying of 12 mm laminated Wooden flooring of AC5 grade with 100 hours of water resistance, scratch proof, antibacterial quality, anti static flooring of eco friendlywith plank size of 1234 x 196mm of reputed brand such as (Lamiwood/ SKIPPER) of design/shade Butterscotch walnut #6026. Rate includes complete installation with backing foam, necessary adhesive etc. including the cost of all materials, cost of all labour, conveyance, loading & unloading, and T&P, etc. complete in all respect as per direction of the Engineer in Charge 66 Melamine polishing to wood work one or more coats including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. 67 Supplying and fixing of Charcoal louver(combination of charcoaland polystyrene 8 to 12 mm thickin the way indicated by manufacturer (EUROPRATIK or equivalent brand) as per the design including cost of all material and labour etc. Complete as per the direction of Engineer-in-charge. 68 Supplying andfitting andfixing ofpanel Mouldingsof approvedmanufacturer with Width 65/22mm as per the design including cost of all material and labour etc. Complete as per the direction of Engineer-in-charge. 69 65mm 70 22mm 71 Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete 72 Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge 73 Providing and fixing 12mm Thick Framelessof Toughened Glass door shutter of approved brand and Manufacture, Including providing and fixing top and bottom pivot double acting hydraulic froor spring type fixing arrangement and making Necessary Holes etc for fixing required door fittings all complete asper direction of Eic.(Door handle ,lock and stopper etc paid to be separately. 74 Chromium plated fittings (Brass) (I.S.I.) Handle (I.S.I) of 125mm with 175 x 32mm plate s per drawingand specification including cost of all material T&P, etc, complete as per the direction of Engineer-in-Charge. 75 Providing & Supplying of Thrill Mesh Full Back Chair ( Black Body Black Ink),Mesh Back, 1D Adjustable Armrests, Centre Tilt Synchro Mechanism, 3 Pos Lock, Nylon Pedestal, Width: 76.1 CM, Depth: 76.1 CM, Height: 101.5-111.0CM & Seat Height: 44.5-54.0CM of godrej make or equivalent as per drawingand specification including cost of all material T&P, etc, complete as per the direction of Engineer-in-Charge. 76 Providing and fixing in position wardrobe 450mm deep with shutters out of 18 mm thk. BWP ply & shelves out of 18mm BWP ply at appropriate locations with necessary support buttons. The storage to be finished externally with 1 mm thick laminate of approved shade & internaly finished in1mm laminate with SS hinges, tower bolts, ballcatches lock, Handle (8 SS handle) etc. complete in all respects as per detail drawing & instructions of Engineer-in-Charge. 77 Providing & Fixing of Wall Panelling made out of Aluminum Section B 9835 as Horizontal & Vertical member placed @ 600 mm C/C Covered with 12 mm thick BWR Ply and 1mm thick laminate etc. complete in all respects as per detail drawing & instructions of Engineer-in-Charge. 78 Providing & Supplying of Single Seater Leather SofaOverall Size :Width: 92cm, Depth : 87cm, Height : 76cm, Seating Height : 39.5cm STITCHING: THREAD : Poly Proplin, LEATHER/PVC/FABRIC: PVC. Thickness (mm) : 0.9 Weight (GSM) : 575 of PATRO godrej make or equivalent as per drawingand specification including cost of all material T&P, etc, complete as per the direction of Engineer-in-Charge. 79 Providing & Supplying Three Seater Leather Sofa Overall Size : Width: 134cm, Depth : 87cm, Height : 76cm, Seating Height : 39.5cm STITCHING: THREAD : Poly Proplin.LEATHER/PVC/FABRIC: PVC. Thickness (mm) : 0.9 Weight (GSM) : 575 of PATRO godrej make or equivalent as per drawingand specification including cost of all material T&P, etc, complete as per the direction of Engineer-in-Charge. 80 Providing & Supplying of Center Table with Glass Top and wooden leg of Width: 100CM, Height: 45CM & Depth 65CM of Alice godrej make or equivalent as per drawingand specification including cost of all material T&P, etc, complete as per the direction of Engineer-in-Charge. 81 Providing & fixing Patachitra panneling. including all the cost of material & labour , t& p, taxes, etc complete and as per the direction of EIC/ architects. 82 Providing & fixing of THATCHED ROOF of minimum 45-degree pitch for water runoff, a minimum 175mm (7-inch) and maximum 250mm (10-inch) finished thatch thickness for water resistance and insulation. The structural timber must be CCA treated to specified standards, and the thatch itself must be well-compacted for durability including all the cost of material & labour , transportation etc complete and as per the direction of EIC. 83 MODULAR KITCHEN 84 TANDOOR VATTIWITH INSIDE CLAY POT WITH GAS FRIED Body & Top:- Top Underneath by40X40X5 thk.M.S. Angle Frame with rust proof paint, Covered by 16 S.W.G S.S. Sheet at Top Portion and Side Covered by18 / 20 S.W.G. S.S. Sheet with heavy duty 4” M.S. Wheel fittings. Inside clay pot. Insulation:- Glass wool Insulation. Others Fittings:- Fitted with Suitable heavy duty L.P.G. Burners, Needle Control Valve,with Heavy Duty M.S. Plate. 85 TANDOOR TABLEWITH 01 NO. BOTTOM SHELVE of Overall Size:- 600X800X900+150 Body & Top:- Top Underneath by 40X40X5 thk. M.S. Angle Frame with rust proof paint, Covered by 16 S.W.G S.S.Sheet at Top Portion and Bottom Shelve 18 / 20 S.W.G. S.S. Sheet. Leg:- Fabricatedfrom 40mmX40mmS.S.squarepipe with adjustable fibber built. 86 TWO BURNER COOKINGRANGE WITH ALL FITTINGS of Overall Size:- 1200X700X850+150 Body&Top:-TopUnderneathby40X40X5 thk.M.S.AngleFramewithrustproof paint,Coveredby16S.W.GS.S304 qualities Sheet at Top Portion and Side Covered by18 / 20 S.W.G. S.S. 304 quality Sheet with S.S. drip trays.Leg:- Fabricated from 40mmX40mm S.S. 304 quality square pipe with adjustable fibber built. Others Fittings:- Fitted with Suitable heavy duty L.P.G. Burners, Needle Control Valve, Pilot Lamp & copper pipe with Heavy Duty C.I. Pan Support. 87 SINGLE SINK UNIT of Overall Size:- 600X700X850+150Body & Top:- Top Underneath by 40X40X5thk. M.S. Angle Frame, Covered by 16S.W.G S.S 304 qualities Sheet at Top & Sink Bowl with Front Side (up-to Sink Bowl)Coveredby20S.W.G.S.S.304quality Sheet.Leg:- Fabricated from 40mmX40mm S.S. 304 quality square pipe with adjustable fibber built. 88 (2+1) CHINESE COOKING RANGE WITH ALL FITTINGS of Overall Size:- 1650X750X850+300 Pan-support Size:- Three Round Pan- supportBody & Top:- Top Underneath by40X40X5 thk.M.S. Angle Frame with rust proof paint, Covered by 14 S.W.G S.S.Sheet at Top Portion and SideCovered by18 / 20 S.W.G. S.S.Sheet with S.S. drip trays and drainage & Water spray System. OthersFittings:-Fittedwith Suitableheavy dutyL.P.G.Burners, Needle Control Valve,Pilot Lamp&copperpipewithHeavyDutyC.I.PanSupport. 89 SINGLE BURNERCOOKING RANGE WITH ALL FITTINGS of Overall Size:- 600X750X850+150Body & Top:- Top Underneath by 40X40X5 thk.M.S. Angle Frame, Covered by 16 S.W.G S.S Sheet at Top Portion and Side Covered by18 /20S.W.G. S.S. Sheet. Leg:- Fabricated from 40mmX40mm S.S. square pipewith adjustable fibber built.Others Fittings:- Fitted withSuitable heavy duty L.P.G.Burners, Needle Control Valve,Pilot Lamp & copper pipe with Heavy Duty C.I. Pan Support. 90 WORK / SIDE TABLE WITH 02NOS. BOTTOM SHELVE of Overall Size:- 1100X700X850+150Body&Top:-TopUnderneathby 40X40X5thk.M.S.AngleFrame with rust proof paint, Covered by16 S.W.G S.S 304 qualities Sheet at Top Portion and Bottom Shelve 18/20S.W.G.S.S.304quality Sheet. Leg:- Fabricated from 40mmX40mmS.S. 304 quality square pipe with adjustable fibber built. 91 DOSA HOT PLATE WITH THREE SIDE COVER & ALL FITTINGS of Overall Size:- 900X750X850+150Body & Top:- Top Underneath by 40X40X5 thk.M.S.AngleFrame,SideCovered by18 / 20 S.W.G. S.S. Sheet with Oil collector.Leg:-Fabricatedfrom40mmX40mmS.S.squarepipewithadjustablefibberbuilt. Others Fittings:- Fitted with Suitable heavy duty L.P.G RV Burners, NeedleControl Valve, Pilot Lamp & copperpipe with Heavy Duty 16mm M.S. Plate. 92 DOBLE DOOR UNDER COUNTER FREEZER of Overall Size:- 1500X700X850Body:-Fabricated from 40X40X5 thk. M.S.AngleFramewithrustproof paint, Top Covered by 16 SWG S.S. 304 qualities sheet. Out-side body Covered by20S.W.GS.S304qualitiesSheet and Inner Tank 22/24 S.W.G. S.S. 304 qualitySheet.SpringfittingsDoor with lock & Key Facility.Leg:-Fabricatedfrom40mmX 40mmS.S. 304qualitysquarepipewith adjustable fibber built.Insulation:- Puff Type Insulation Body & Door.CoolingSystem:-Copperpipecoiling with direct cooling System.Others Fittings:- Fitted with Emerson Make compressor, Heavy Duty Fan / Motor, Heavy Duty Condenser with Copper Coiling, Digital temperature controller display & On-Off Switchfittings. 93 OVER HEAD SHELEV FOR UNDER COUNTER FREEZER of Overall Size:- 1500X250X450+300All shelve 18SWG S.S. S.S. Sheet, Supporting Legs fabricated from 25mm dia. S.S. Pipe. 94 PICK-UP TABLE WITH 02NOS. BOTTOM SHELVE 95 Overall Size:- 600X700X850Body & Top:- Top Underneath by 40X40X5 thk.M.S. Angle Frame with rust proof paint,Coveredby16S.W.GS.S Sheet at Top Portion andBottom Shelve 18/20 S.W.G. S.S. Sheet.Leg:-Fabricated from 40mmX40mmS.S.squarepipe with adjustable fibber built. 96 PICK-UP TABLE WITH 02 NOS. BOTTOM SHELVE of Overall Size:- 1100X700X850Body&Top:-TopUnderneathby 40X40X5thk.M.S.AngleFrame with rust proof paint, Covered by 16 S.W.G S.S 304 qualities Sheet at Top Portion and Bottom Shelve 18/20S.W.G.S.S.304quality Sheet. Leg:-Fabricated from 40mmX40mmS.S. 304 quality square pipe with adjustable fibber built. 97 OVER HEAD SHELEV FOR UNDER COUNTER FREEZER of Overall Size:- 1100X250X450+300All shelve 18SWG S.S. S.S. Sheet, Supporting Legs fabricated from 25mm dia. S.S. Pipe. 98 04- DOOR FREEZER of Overall Size:- 1200X750X2000Body:-Fabricated from 40X40X5 thk. M.S.AngleFramewithrustproof paint,TopCoveredby16SWGS.S. sheet.Out-sidebodyCoveredby20 S.W.G S.S Sheet and Inner Tank 22/24 S.W.G.S.S.Sheet.Springfittings Door with lock & Key Facility.Leg:-Fabricatedfrom40mmX40mmS.S. squarepipewithadjustablefibber built.Insulation:- Puff Type Insulation Body & Door.CoolingSystem:-Copperpipecoiling with direct cooling System. Others Fittings:- Fitted with Emerson Make compressor, Heavy Duty Fan / Motor, Heavy Duty Condenser with Copper Coiling, Digital temperature controller display & On-Off Switch fittings. 99 DOUBLE DOOR DEEP FREEZER of Capacity:-500ltrs. VOLTAS / Western Make 100 TABLE WITH SINK & 01No. BOTTOM SHELVE 101 Overall Size:- 1500X700X850+150Body & Top:- Top Underneath by 40X40X5 thk. M.S. Angle Frame with rust proof paint,Coveredby16S.W.GS.S304 qualitiesSheetatTopPortionand BottomShelve18/20S.W.G.S.S.304 quality Sheet. Leg:- Fabricated from 40mmX40mm S.S.304 quality square pipe with adjustable fibber built. 102 DISH & POT WASHING AREA:- 103 3-SINK UNIT FOR PLATE WASHING Overall Size:- 1650X600X850+150Body & Top:- Top Underneath by 40X40X5 thk.M.S. Angle Frame with rust proof paint, Covered by 16 S.W.G S.S Sheet at Top & Sink Bowl with Front Side (up-to Sink Bowl) Covered by 20 S.W.G. S.S. Sheet. Leg:- Fabricated from 40mmX40mm S.S. square pipe with adjustable fibber built. 104 PRE RINSE UNIT.Deck Mounted Water Faucet / Shower System (Single) 105 4”- DEEP SOILDISH LANDINGTABLE WITH SOILHOLE & OVER HEAD SHELVE. Overall Size:- 1100X700X850+450+300Body & Top:- Top Underneath by 40X40X5 thk. M.S. Angle Frame with rust proof paint, Covered by 16 S.W.G S.S 304 qualities Sheet at Top Portion & Over head shelve 18 S.W.G. S.S. 304 quality Sheet & 25mmDia Pipe. Leg:- Fabricated from 40mmX40mm S.S. 304 quality square pipe with adjustable fibber built. 106 CLEANING DISH TABLE WITH 01NO. BOTTOM SHELVE of Overall Size:- 600X700X850+150Body & Top:- Top Underneath by 40X40X5 thk. M.S. Angle Frame with rust proof paint, Covered by 16 S.W.G S.S Sheet at Top Portion and Bottom Shelve 18/20 S.W.G. S.S. Sheet.Leg:- Fabricated from 40mmX40mm S.S. square pipe with adjustable fibber built. 107 SOIL DISH COLLECTION TROLLEY WITH 01NO. BOTTOM SHELVE of Overall Size:- 900X600X900Fabricated from 16/18 SWG 304 quality S.S. Sheet at top portion & Handle fabricated from 40mm dia. 304 quality S.S. Pipe with heavy duty wheel. 108 CLEAN DISH RACK WITH 04NOS. SHELVE of Overall Size:- 1100X450X1650Shelve:- Shelve Fabricated From 18 S.W.G. S.S 304 qualities Sheet.Leg / Supporting Stand:- Fabricated from 40mmX40mm S.S. 304 quality square pipe with adjustable fibber built. 109 POT RACK WITH 04NOS. SHELVE of Overall Size:- 1500X600X1950Shelve:- Shelve Fabricated From S.S. 20mm / 25mm square pipe.Leg / Supporting Stand:- Fabricated from 40mmX40mm S.S. square pipe with adjustable fibber built. 110 STORAGE RACK & OTHERS:- 111 S.S. STORAGE RACK WITH 04NOS. SHELVE FOR DRY STORE of Overall Size:- 1100X450X1650All Supporting Legs fabricated from S.S. Square pipe with adjustable fibber built and all shelve fabricated from 18 SWG M.S. Sheet. 112 VENTILATION SYSTEM:- Exhaust System 113 S.S. SUCTION HOOD WITH S.S. BAFFLE FILTER FOR COOKING RANGE TOP (CANTILEVER TYPE). Overall Size:-6600X900X450 Fabricated from 20/22 SWG S.S. 202Quality S.S. Sheet & S.S. Baffle Filter with Double frame for Suction Hood Fabricated from 24 SWG S.S. sheet. 114 AIR CONTROL DAMPER Overall Size:- 300X300X100Fabricated from 24 G.I. SWG sheet. 115 03 NEW G.I. DUCTING INSIDE & OUT-SIDE KITCHEN FOR EXHAUST SYSTEM Overall Size:- DifferentFabricated from 22/24SWG G.I. sheet. 116 5HP Centrifugal Fan WITH all FITTINGS 117 FRESH AIR :- NEW G.I. DUCTING INSIDE & OUT-SIDE KITCHEN FOR EXHAUST SYSTEM Overall Size:- DifferentFabricated from 22/24SWG G.I. sheet. 118 AIR ADJUSTABLE LUBBER AT AIR OUTLET POINT Overall Size:- 18X8Fabricated From 24SWG G.I. Sheet. 119 2HP AXIAL FLOW Fan WITH allFITTINGS 120 L.P.G SYSTEM:- MANIFOLD 5X2 =20Nos.CYLINDERS ofFabricated from 25 N.B. Seamless Sch.40 M.S. Pipe. 121 NON RETURN VALVE of H.P.C / Gaso Make 122 CYLINDER FLEXIBLE PIGTAIL of 24” Long Super seal / Surakha Make 123 CLICK-ON-ADAPTOR of Gaso Make 124 1st STAGE REGULATOR of 30 PSI, Venaz / Gaso Make 125 HAND SHUT-OFF VALVE of 25mm valve RV, Koria / Acron make 126 HAND SHUT-OFF VALVE of 20mm valve RV, Koria / Acron make 127 M.S. PIPE LINE of 25mm dia. Pipe line with tee, elbow, Socket etc Seamless scheduled 40 M.S. Pipe with Wall Clump. 128 M.S. PIPE LINE of 20mm dia. Pipe line with tee, elbow, Socket etc Seamless scheduled 40 M.S. Pipe with Wall Clump. 129 NEEDLE CONTROL VALVE of HPC / Gaso Make 130 M.S.ADAPTOR of size ¾” X ¾” & 1” X 1” 131 M.S. NUT & NIPPLE SETof size ¾” X ¾” & 1” X 1” 132 PRESSURE GAUGE WITH VALVE of 0 – 50 PSI 133 OVEN PIPE / OVEN PIGTAIL of 60” Long Super seal / Surakha Make 134 SPARK ARRESTOR FOR FIRE SAFETY of 1”X1”Venaz / Gaso Make 135 GAS LEAKAGE DETECTORof Model :-GT-07Victory Gas Alarm Company Make 136 PRESSURE TESTING & INSTALLATION CHARGE of Pressure Testing by Nitrogen 137 PATHWAY 138 Earthwork in excavation in all kinds of soil upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, DI rocks etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. 139 Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). 140 Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works(4th Revision) 141 Supplying & fixing of pre cast kerb stone of size 600mm x 300mmx150mm of M-30 grade of approved make desgin ,colour & size made by block making machine with proper compaction fixed in required pattern etc.complete in all respect conforming to IS 5758:1984. 142 Supplying and laying ofhydraulically pressed and mechanically compacted free cast interlocking UNI PAVERpavers of 80MMthick of different colour , coral shaped preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. 143 LANDSCAPE 144 Supply of good quality garden soil preferably red alluvial /sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining capacity sufficiently porous for microbial activity, containing adequatehumus with a Ph range from 6.5 to 7.5 should be freefrom any undesirable inorganic materials like wastages of construction, roots and bushes of wild plants, polythene, garbage etc., including cost, conveyance, royalty etc. as per the direction of the EIC . 145 Lifting & spreading of good soil uniformly over the surface area as per landscape design etc. complete as per the direction of the EIC . 146 Supply of cow dung manure, well decomposed, garbage free includingincluding cost, conveyance ,loading, unloading etc. complete as per the direction of the EIC . 147 Lifting & Spreading of cow dung manure uniformly etc. complete as per the direction of the EIC . 148 Supplying & Turfingof Selection-1grass carpet of 2 thickwith well grown disease free grass including loading and unloading and delivery at site & Turfing of grass carpet including watering, rolling as per requirement etc. complete as per direction of Engineer-in-charge. 149 Supplying & Planting of Foxtail palm6’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 150 Supplying & Planting of Hedge plants kamini 16” ht.plants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 151 Supplying & Planting of Almonda 2½’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 152 Supplying & Planting of Plumeria 6 htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 153 Supplying & Planting of Ficus panda30” ht.plants (bushy type) of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 154 Supplying & Planting of Sampen palm50” ht.plants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 155 Supplying & Planting of Pandanus10” ht.plants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 156 Supplying & Planting ofBakul 6’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 157 Supplying & Planting ofSyngonium10’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 158 Supplying & Planting ofJuniper4’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 159 Supplying & Planting of Foxtail palm10’ htplants of well established ,healthy , disease free type transported with poly bag including cost of transportation ,loading / Unloading etc. , planting of each plant at specified location inluding cost of all labourfor earth work , application of Manure / fertilizer / pesticide etc as per requirement etc. complete in all respect as per the direction of the instruction of Engineer- in-charge. 160 WATER SUPPLY & SANITARY WORKS 161 Supplying all materials, labours, T&P for fitting and fixing white glazed vitreousItalian floor mounted rimless one piecewash down European water closet of hindware make having Hindware Flora cat no 20107 or equivalent type of approved make including all fittings with supply of matching P/S trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete including cost of WC pan, PVC seat cover with CP brass hinges and rubber buffers etc all complete including cost, taxes and conveyance as per specification including polishing etc all complete as per PH specification and direction of Engineer-in-charge. 162 Supplying all material, labour T&P and fixtures for providing and fixing of white glazed vitreous chinaware Full Pedestal wash hand basin of size 55x40x80cmof Hindware make NEO model having cat no - 10098 & Ped. - 11032 or equivalent type of approved make with 32mm dia waste pipe with CP waste coupling nut of Jaquar make having cat no ALD 709 and 15mm x 450mm PVC connection pipe of Jaquar make having cat no ALD 803AB with MS bracket with wooden plugs CP screws including cost of cement, sand, labour, T&P etc. complete including testing cost, conveyance, royalty and taxes of all materials etc. complete as per PH specification and direction of Engineer-in-charge. 163 Supplying all materials, labour, T&P and fixing mirror of superior glassmounted on 6mm thick A.C sheet or plywood sheet and fixed to woodenplugs with CP screws and washers complete as per specification and direction of the Engineer in charge 164 Supplying all materials, labour, T&P and fixing standard sized15mm dia Angular Stop cock of Jaquar Cat. No.- FUS - 29053or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 165 Supplying all materials, labour, T&P and fixing standard sized15mm dia Concealed Stop cock of Jaquar Cat. No.- FUS - 29083Kor equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 166 Supplying all materials, labour, T&P and fixing standard sizedWall Mixture of Jaquar Cat. No.- FUS - 29281or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 167 Supplying all materials, labour, T&P and fixing of 120mm dia CP overhead shower of Jaquar Kubix Cat. No.-OHS-1709 with arm SHA-477 or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 168 Supplying all materials, labour, T&P and fixing standard sizedpillar cock of JaquarCat. No.-FUS - 29001 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 169 Supplying all materials, labour, T&P and fixing two way Bib cock of JaquarCat. No.- FUS - 29041or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 170 Supplying all materials, labour, T&P and fixing health faucet of Jaquar Cat. No.-ALD-565 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 171 Supplying all materials, labour, T&P and fixing standard sizedCP towel rail - 24of Jaquar Cat. No.-AKP 35711PS or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 172 Supplying all materials, labour, T&P and fixing standard sizedCP towel ring of Jaquar Cat. No.-ACN - 1121BN or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 173 Supplying all materials, labour, T&P and fixing standard sizedCP Soap case of Jaquar Cat. No.-AKP-35731P or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 174 Supplying all materials, labour, T&P and fixing standard sizedCP Glass Shelf of Jaquar Cat. No.-AKP 35771P or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 175 Supplying all materials, labour, T&P and fixing standard sizedCP Paper Holder of Jaquar Cat. No.-AKP 35751P or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 176 Supplying all materials, labour, T&P and fixing standard sizedCP Bib cock of Jaquar Cat. No.- FUS - 29037 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 177 Providing and fixingcircular type stainless steeljalli (grating) with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge 178 Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes (selfit / ring fit type)with all PVCfittings of Finolex /Prince/Supreme make as per IS 13592to walls with nails, bobbins and wooden plugs or laying in trenches including all pipe fittings, jointing materials, tools plant, labour & all material, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 179 160 mm dia 180 110 mm dia 181 90 mm dia 182 Providing and fixing UPVC pipes of Schedule-80 ( AJAY/ ASHIRVAD/ ASTRAL)including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 183 25 mm nominal outer dia Pipes 184 32 mm nominal outer dia Pipes 185 50 mm nominal outer dia Pipes 186 Providing and fixing UPVC fullwayvalve of approved make and quality with all materials, labour, tools, plant, scafolding , making good the damages caused, complete in all respects 187 25 mm dia 188 32 mm dia 189 40 mm dia 190 50 mm dia 191 Supplying all materials, labour, T&P and fittings and fixing of 2000 ltr Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately) 192 Supplying all materials, labour, T&P, fitting and fixing of UPVC SWR fittings of approved make with requisite testing etc complete as per PH specification and direction of Engineer-in-charge. 193 110mm dia Single Junction with door 194 100mm dia Double Junction with door 195 110mm dia Cowl 196 110mm dia Plain Bend 197 110mm dia SWR Door Bend 198 100mm dia End Plug 199 110mm dia Pipe clip 200 75mm dia Plain Bend 201 Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size 250mm x 250 mm with CI gulley trap, by flyash brick masonry in CM (1:4), CP (1:3) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:3:6) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge. 202 Construction of circular brick masonary manhole chamber of size 900x800x450mm including cement concrete (1:3:6) in bed by using 40mm size granite metal, brickwork in CM (1:4) in foundation & plinth, cement plastering (1:3) over flyash brick, plastering in CM (1:3) with neat cement punning, CC (1:2:4) over bed for benching and channeling, RCC M30 for roof slab of 150mm thick and supply fitting and fixing SFRC medium duty type cover including cost of centring and shuttering cost of MS rod for RCC work, supplying fitting and fixing of the polypropelen step iron of required interval etc all complete with all cost, conveyance, royalties taxes etc all complete as per direction of Engineer-in-charge. 203 Extra for ever additional depth of 100mm or part there of 900x800x450mm chamber 204 Providing and laying in trench cement concrete ( 1:3:6 ) with 40mm size hard granite metal in the following type of bedding for pvc pipes of the following internal diameter including curing complete as per specification (A1-Type Bedding) 205 150mm Dia 206 SIGNAGES 207 Fabrication, supply and fixing of informatory retro reflective signboards using super high efficiency, TYPE XI sheeting as per IRF 67-2012 Code with white color bonded on to 3mm Aluminium Composite panel (0.25+3.50+0.25 -PVCF coated) cover which alphabets and unberals are reverse cut made using Electro cut able film with comuterized cuttng plotter/DIGITAL PRINTING SYSTEM the board shall be provided with frame mode out of stainless steel pipes of 304 grade. it shall be maunted on vertical posts made out of 80mm NB Stainless pipe including necessary excavation for M-20 foundations concreting/reveling, etc necessary for fixing fo the board and conveyance of all materials, equipment, machinery and labour with all leads and lifts, loading and unloading charges all taxes etc complete in all respect as per specification & direction of Engineer-in-Charge. 208 a) Required retro reflective boards of white, yellow, green, blue , brwon colour with necessary signage as per specification & direction of Enginner-in-charge 209 New board -5x6-0x4-0= 210 b) Required stainless stell frame of 80mm NB made out of 304 grade steel pipe including cost, all taxes , transportation complete as per specification & direction of Engineer-in-Charge. 35Kg per Signage 211 5x35kg 212 Providing and laying plain cement concrete of proportion (1:2:4) in foundation and floors using Portland slag cement (PSC) with 12mm size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleared including hoisting, lowering, laying corncrete, ramming, watering and curing etc complete to required levels laid in layers not cxceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalities an dtaxed all materials and cost of all labours, sundries T&P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per specifiation and direction of Engineer-in-Chrge. (0.45x0.45x0.63 = 0.1275) x2= 0.255 Cum Per Nos 213 PHOTOGRAPHY ZONE 214 Earthwork in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders requiring blasting including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge. 215 Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. 216 Supplying and filling in foundation trenches and plinth, ditches with sand well-watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only). 217 Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. 218 Brick work in foundation and plinth with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. 219 Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. 220 Supplying and laying of heavy duty factory made hydraulically pressed and mechanically compacted pre-cast interlocking pavers of 80mm thick,preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. 221 Providing and Fixing white fiber made Selfie point ( I Love GETANJALI RESTAURANT of 4 feet height )as per design and specification with artifical tree and seven numbers wild Monkey on it as per the direction of The architect 222 Providing 20mm thick of above 0.40 Sqm granite tile flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. 223 Providing 20mm thick of above 0.40 Sqm granite tile flooring of approved quality, colour and size in dado/skirting , riser of stepsin all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. 224 Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. 225 INTERNAL WIRING. 226 Recessed / Surface wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havells/Eq) (Make of modular box,cover,switch & socket-Legrand Arteor/schneider Zencelo/Panasonic Vision/Eq) 227 GROUP-A 228 GROUP-B 229 GROUP-C 230 Recessed / Surface wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Polycab/ Anchor / Havels/Eq)Average Length: 3mtr 231 Recessed / Surface wiring to ceiling fan point with 1.5 sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Polycab/ Anchor / Havels/Eq)Group c 232 Recessed / Surface wiring to Twin control light pointwith 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Polycab/ Anchor / Havels/ Finolex/Eq)Group C 233 Supply and fixing of 5 / 6 amp socket outletwith6 Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer-in-charge. 234 Recessed / Surface wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Polycab/ Anchor / Havels/ Finolex /Eq) 235 Supply and fixing of2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. 236 Supply and fixing of1x 6 + 1x16 amp socket outlet controlled by 1x 6 + 1x16 amp6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. 237 Supply and fixing of 6 pin 16 amp socket outletwith 16 Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 238 Supply and fixing of 6 pin 16 amp socket outletISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 239 Supply and fixing of 32 amp Modular DP switchISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 240 Recessed wiring of modular type 1500mA, 5V Type-A USB CHARGER 1M with 6A 250V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size, including all accesories and connection on existing switch board as per direction of Engineer in Charge.(Make- Schneider (Zencelo) / Legrand (myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) 241 Supply and fixing of A.C/ Power socket outletwithindustrial type socket outlet,plug top and metal chained cover in sheet steel enclosure, 20A /32A SP MCBincluding all accesories and connection as per direction of Engineer-in-charge. 242 Supply and fixing of TV / Telephone Socket outletISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 243 Supply and fixing of3 x 6 amp socket outlet controlled by 2 nos6 Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. 244 SUBMAIN WIRING. 245 Recessed / Surface wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) 246 Recessed / Surface wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) 247 Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) 248 Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make-Finolex/ Anchor/Polycab /HAVELLS /RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit.(2X6+1X2.5) 249 Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make-Finolex/ Anchor/Polycab /HAVELLS /RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit.(4X4+1X2.5) 250 Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make-Finolex/ Anchor/Polycab /HAVELLS /RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit.(4X6+1X2.5) 251 Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make-Finolex/ Anchor/Polycab /HAVELLS /RR KABLE inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit.(4X10+1X4) 252 DISTRIBUTION BOARD 253 Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid tripposition for toggles for electrical fault conditions.(With 2 Years Warenty) 254 Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63Amp / 40AmpFPMCB (10KA)Outgoings-10/16/20A SP MCB 10KA-12Nos of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make-L&T/ Hager/ Schneider/ Legrand/ Eq) 255 Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door Vertical type powder coated wall mounted4 way Vertical TPN Distribution Boardssuitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40A/63A/80A/100AFPMCCB (25KA)Outgoings-10/16/32A SP MCB 10KA-12Nos of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make-L&T/ Hager/ Schneider/ Legrand/ Eq) 256 FITTING & FIXTURE 257 Supply, Installation, Testing and Commissioning of Plastic body Exhaust fan200 mm sweep 900 rpm with louversof approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/ Crompton/ Usha/ Orient/Bajaj). 258 Supply, Installation, Testing and Commissioning of Metal body Exhaust fan380 mm sweep 1400 rpm vheavy duty of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/ Crompton/ Usha/ Orient/Bajaj). 259 Supply, Installation, Testing and Commissioning of 1200 mm sweep 4 blades Decorative ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make-Havells Florence/Crompton /Usha/Orient /Bajaj). 260 Supply, Installation, Testing, and commissioningofdecorativeWallfan300mm sweep,110watt,230/250volts,50HZ complete with suitable, clamp, downrod (as persiterequirement),blades,canpoy, rubber, shackle, and connections with 1.5 sq.mmPVCinsulatedcopperconductorcable etc as required of approved make complete withallmaterials&labourasrequiredasper thedirectionofEngineer-in-Charge. ( Make- Havells/Crompton /Usha/Orient /Bajaj) 261 Supply, Installation, Testing, and commissioningofdecorative pedestalfan 450mmsweep,120watt,230/250volts,50HZ complete with suitable, clamp, downrod (as persiterequirement),blades,canpoy, rubber, shackle, and connections with 1.5 sq.mmPVCinsulatedcopperconductorcable etc as required of approved make complete withallmaterials&labourasrequiredasper the direction of Engineer-in-Charge. ( Make- Havells - V2 Neo/Crompton /Usha/Orient /Bajaj) 262 SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories withdiffuser of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 263 SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 10 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories withdiffuser of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 264 SITC of9 watt LED Ceiling Recessed mounted Downlight with Low depth Aluminium (99% Purity) Heat Sink, available in Round and Square shape. PC diffuser in white powder coated finish with independent electronic low THD (<10%) LED driver of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 265 SITC of12 watt LED Ceiling Recessed mounted Downlight with Low depth Aluminium (99% Purity) Heat Sink, available in Round and Square shape. PC diffuser in white powder coated finish with independent electronic low THD (<10%) LED driver of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 266 SITC of 3 watt LED Ceiling Recessed mounted spot light in different Colour Aesthetically designed lens based of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 267 SITC of LED Strip light, IP65 protection of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 268 SITC of18 watt LED Ceiling Surface mounted Downlight with Low depth Aluminium (99% Purity) Heat Sink, available in Round and Square shape. PC diffuser in white powder coated finish with independent electronic low THD (<10%) LED driver of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj). 269 Supply, Installation,Testing & commissioning ofDecorative Vega Outdoor wall light, Metal glass , Bronze finish, Holder & Plug Type E27 , Dimensions of Light: 26 X 19 X 52 CM ; Canopy: 12 X 28 CM of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge. (Vega / Eqivalent) 270 Supply, Installation,Testing & commissioning of 2W Anthracite LED Step/ Foot Light of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.( Make - Phillips 34151/ Jaquar /Havells /Klite /Phillips /CG/Bajaj) 271 Supply, Installation,Testing & commissioning of 9W LED Integrated wall Light ( Mirror Light) of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.( Make - Phillips 581916/ Jaquar /Havells /Klite /Phillips /CG/Bajaj) 272 Supply, Installation,Testing & commissioning of 12W LED Picture Light Chrome finish of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.( Make - Phillips 31440/ Jaquar /Havells /Klite /Phillips /CG/Bajaj) 273 CCTV SYSTEM 274 Supply of 4 MP IP Audio Dome Camera (20 Mtr IR ) (Inbiult Audio with Color Night Vision) etc complete of approve make as per the direction of Engineer-in-Charge.( Make - CP Plus /Hikvision /Honeywell) 275 Supply of 4 MP IP Audio Bullet Camera (20 Mtr IR) (Inbiult Audio with Color Night Vision) etc complete of approve make as per the direction of Engineer-in-Charge.( Make - CP Plus /Hikvision /Honeywell) 276 Supply of 16 Channel NVR (2 SATA Port ) (Upto 8 Mega Pixel Camera Supported) etc complete of approve make as per the direction of Engineer-in-Charge.( Make - CP Plus /Hikvision /Honeywell) 277 Supply of 4TB Surveillance Hard Disk etc complete of approve make as per the direction of Engineer-in-Charge.( Make - WD/ Seagate) 278 Supply of 16 Port GIGABIT PoE Switch with Fiber Port and GIGA Uplink Port of approve make as per the direction of Engineer-in-Charge.( Make - Tyco / Hifocus / Digisol/Hikvision) 279 Supply of 8 Port GIGABIT PoE Switch with Fiber Port and GIGA Uplink Port of approve make as per the direction of Engineer-in-Charge.( Make -Tyco / Hifocus / Digisol/Hikvision) 280 Supply of 9U Network Rack (Server Room) Includes PDU , FAN and Cantilever Shelf Tray of approve make as per the direction of Engineer-in-Charge.( Make -CP Plus/ Tyco / Legrand / Digisol/Dlink) 281 Supply of 4K HDMI Cable 5 Mtr long of approve make as per the direction of Engineer-in-Charge.( Make - Tyco / Hifocus / Digisol/Honeywell) 282 Supply & Laying ofCat-6 Cable with PVC Pipe and casing of approve make as per the direction of Engineer-in-Charge.( Make - Tyco / Legrand / Panduit /D Link/ Digisol) 283 Installation Testing & Commissioning of CCTV System etc Complete. 284 Supplying, installation, testing & commissioning of 43 Smart LED Television, 4K UHD,Vibrant Viewing in Ultra High Resolution, commercial type ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.(LG/Samsung/Sony) 285 SAFETY EQUIPMENTS 286 Providing and fixing carbon-di-oxide type 4.5 KG fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed towall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire 287 Providing and fixing ABC type 6 KG fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed towall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire 288 Supply and installation of Rubber Mats 12mm thick of size 2000 mm x 1000mm x 12 mm thick Electrical tested with test certificate. 289 Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. 290 Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. 291 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 292 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 293 Providing and fixing Main Fire Alarm Control Panel - 4 zone with all necessory accesorries ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.. 294 Electrical Gadgets 295 Supplying, Installation, Testing & Commissioning of 2 Ton Tower AC machine ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.(LG/Voltas/Bluestar/ Carrier /Daikin) 296 Supplying, Installation, Testing & Commissioning of Extra Refrigeration Copper pipe with insulation & drain pipe ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 297 Supplying, Installation, Testing & Commissioning of Hi-wall 2 Ton Split AC of 5 Star Rating ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge.(LG/Voltas/Bluestar/ Carrier /Daikin) 298 Supplying, Installation, Testing & Commissioning of 5 Kva wall hanging Stablizer ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. (Vguard /Voltas/Sakti) 299 Supplying, Installation, Testing & Commissioning of Out door stand for fixing of Out door unit ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 300 Supplying, Installation, Testing & Commissioning of Concealed Light Chandeliers Color: Gold, Material: Brass, No. of heads: 12, Cap type: E14, Wattage: 12 x 4.5 W LED, Dimension (mm): Ø 610 x H 920, Weight (Kg): 20.5 ofapproved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. (Jaquar - Nobella / Equivalent) 301 External Illumination 302 Supplying, installation and commissioning of 12 W LEDVerbena Square Bollard light 1000 mm long. Body : Square Aluminium Tube,Mounting : Surface - FloorFinish : Powder coated etc complete with connection as required for the work and as per direction of Engineer-in-Charge.(Make: K- Lite KL-4735/Havells / BAJAJ/ CG/ Jaquar). 303 Supply of 8 mtrlong single arm hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos.En 8 grade foundation bolts to withstand basicwind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge. 304 Supply, installation, testing & commissioning of 3050 mm long decorative lighting pole with mild steel body step pole with grey/black powder coting fnish. The control gear tray made up off diecast alluminium body & prewired with 2.5 sqmm copper cable, 6 Amp SP MCB, 32 Amp 4 pole connector, 5 Amp 3 way terminal connector & earthing point. The Pole shall have base Plate of size (200x12) mm with provision for founation bolt fittings.Compatible for all suitable size for cable entry & exist as required of approved make with all materials & labour as per the direction of Engineer-in-Charge.(Make: K- Lite Flat Series KP-4786/ Havells / BAJAJ/CG/Jaquar). 305 Supply, installation, testing & commissioning of coil earthing etc as required as per the direction of Engineer-in-Charge. 306 Supply, installation, testing & commissioning of 30 watt LED post top light fittings integrated with LED Modules, Clear Polycarbonate optical cover, Protection class IP 65, Integral power supply, Earth connection, BIS Mark as required of approved make etc complete with all materials & labour as per the direction of Engineer-in-Charge. (Make: K -lite Avira KL- 4976/ Havells / BAJAJ/CG/Jaquar). 307 Supply, installation, testing & commissioning of 10 watt LED 2 Way Wall light fittings integrated with LED Modules, Protection class IP 65, Integral power supply, Earth connection, BIS Mark as required of approved make etc complete with all materials & labour as per the direction of Engineer-in-Charge. (Make: Phillips - 31450 /K -lite / Havells / BAJAJ/CG/Jaquar). 308 Supply, installation, testing & commissioning ofIP 65 LED street Light of 90 W Capacity 6000K Colour temperature with pressure die-cast Aluminium body havingin built electronic driver which have 50000 burning hour road way luminaries of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge. 309 Supplying, storing, laying, testing and commissioning of 3 c x 4 Sq. mmarmoured Copper Cable direct in groundincluding excavation , sand cushining protective covering and refilling the trench of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 310 Supplying, storing, laying, testing and commissioning of 2c x 6 Sq. mm A2XFY Al armoured Cable1100 Voltsetc. as required of approved make complete with all materials & labour of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge. 311 Supplying, storing, laying, testing and commissioning of 4c x 16 Sq. mm A2XFY Al armoured Cable1100 Voltsetc. as required of approved make complete with all materials & labour of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge. 312 Supplying, storing, laying, testing and commissioning of 3.5 c x 35 Sq. mm A2XFY Al armoured Cable1100 Voltsetc. as required of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 313 Supplying, storing, laying, testing and commissioning of 3.5 c x 70 Sq. mm A2XFY Al armoured Cable1100 Voltsetc. as required of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 314 Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete. MAKE- Legrand / Schneider/Hager/ L&T/SIEMENS/Eq. 315 Main Panel 250 Amp 4 P MCCB 25 KA -1 No, 160 Amp 4P Changeover - 1 no as incomer, 125 Amp 4P MCCB 10 KA -3 nos, 63/80 Amp 4P MCCB 10 KA- 3 Nos, 63/40 Amp 4P MCB 10 KA 2 Nos, , 32 Amp DP MCB 10 KA -2 Nos with copper busbars 4nos of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 316 Supply, installation,testing & commissioning of 63 Amp, DB with IP65 made of environment friendly polycarbonate PC- GFS insulation enclosed indoor electrical panel board as power switch gear and control gear assembly (PSC) in accordance with IEC 61439-2 for wall mounting/floor mounting Part No. HEN MI LDB - 1086 - 2024 The enclousers must be suitable for outdoor installation harsh environment and/ or outdoor installation- The climatic effects on the equipment’s must be considered. Bottom parts and lids of the boxes made from impact resistance polycarbonate, halogen and silicon free colour RAL7035, transparent lid with quick action fastners for tool operation. Burning behaviour according to IEC60695-2-11 glow wire test + 960 degree C. Maximum water absorption 10mg in accordance with DIN53473. Protective measures: Totally insulated (protection classII), the enclosure should have mechanical strength equivalent to IK10.Incomer:63Amp, FP, MCCB,25kA-1no Outgoing:40Amp,DP MCB 10kA-2No, 20Amp, DP 10kA,MCB-3 Outdoor/wall Mounting of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. (Hansel / Equivalent 317 Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 318 Supplying and laying 25 mm x 6 mm Copper earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 319 Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing of approved make complete with all materials & labouras required as per the direction of Engineer-in-Charge. 320 Supplying, storing, laying and commissioning of 40 mm dia HDPE pipe etc as required of approved make complete with all materials & labour as per the direction of Engineer-in-Charge. 321 Supplying, storing, laying and commissioning of 63 mm dia HDPE pipe etc as required of approved make complete with all materials & labour as per the direction of Engineer-in-Charge. 322 62.5 KVA DG SET 323 Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 62.5KVA ( Make -Kirloskar / Jakson) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below.Warrentee period of panel must be 2 years ALTERNATOR:- The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. ENGINE:- Diesel Engine start, developing suitableBHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 62.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Industrial Silencer.04. SMF Batteries with leads as per the Manufacturer standards, AMF PANEL:- Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors,for both main & dg along with battery charger,relay,timer & all required accessories, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 62.5KVA DG Set complete with Battery Charger & leads as requiredBASE PLATE:- Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required.
Contract Date: Mar 06, 2026 Contract Value : 1.55 Crore
Government Departments No of Bidders 14
23.
Power #9638696 AOC
Tender For Construction Of 220/132 Kv, 1X160 Mva;Substation At Balesar (Upgradation)Including Survey Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning On Turnkey Basis Against Specification No. Rvpn/Ehv/Bn-9019002512. - Circuit Breaker 3 220kV circuit breakers (3 Ph.) Along with support Structure 4 2500 A, 50 kA 5 132 kV Circuit Breakers 6 132 kV circuit breakers (3 Ph.) Along with support Structure 7 1250 A, 40 kA 8 Instrument Transformers 9 Capacitor Voltage Transformer 10 Single-Phase, 220 kV, 4400 pf CVT 11 Single Phase 132 kV , 4400 pf CVT 12 Current Transformer (1-Phase) 13 220 kV CT 14 1000/1 A, 5C 15 132 kV CT 16 1000/1 A, 3C 17 500/1 A, 3C 18 C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II) 19 New Substation 20 Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB 21 Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB 22 Control Panel for 220 kV Feeder Type: SAS-FCB 23 Relay Panelfor 220 kV Feeder Type: SAS-FRB 24 Control Panel for 220 kV Bus Coupler Type: SAS-BCCB 25 Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB 26 220 kV Busbar Protection Relay Panel Type: SAS-BBRB 27 Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB 28 Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB 29 Control Panel for 132 kV Feeder Type SAS-FCA 30 Relay Panel for 132 kV Feeder Type SAS-FRA 31 Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA 32 Station HMI [Industrial grade Computer with 21TFT monitor as per specification requirements] 33 Station HMI (Hot Standby)[Industrial grade Computer with 21TFT monitor as per specification requirements] 34 HMI View Node[Industrial grad Computer with 21TFT monitor as per specification requirements] 35 A3 Size B&W Laser Printer 36 Substation Automation System Network Panel Type SAS-NW 37 Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC] 38 Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired 39 Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification. 40 Substation Auxiliary Monitoring Panel Type SAS-SAMP 41 Other Items: 42 Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements. 43 Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards. 44 Surge Arresters 45 220 kV LA 46 132 kV LA 47 Substation LT Transformer 48 33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil 49 Batteries & Battery Charger 50 Batteries (Sizing shall be as per requirement of technical specification) 51 220 V [Min. 600 AH] 52 48 V [Min. 600 AH] 53 Battery Charger System 54 220 V Float and Boost 55 50 V Float and Boost 56 Lighting System 57 Outdoor Lighting & other Works 58 Lighting Fixture Type FL-1 59 Lighting Fixture Type FL-2 60 Outdoor Receptacle 61 Type-RP 62 Type-RO 63 Substation Premises Lighting 64 Lighting poles 65 Type-L1 66 Type-D1 67 Street Lighting Type-SL-L1 for mounting on poles 68 Street Lighting Type-SL-D1 for mounting on Poles 69 Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc. 70 Lighting PanelType ACP-2 as per technical specification 71 Lighting PanelType ACP-3 as per technical specification 72 Indoor Lighting & Other Works 73 Electrification 74 Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room,Hall and administrative office building as per the requirements of the specifications 75 Illumiation 76 Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories andmounting arrangements) 77 Indoor Lignting Panels 78 Lighting Panel (Indoor)Type ACP-1 as per technical specification 79 Lighting Panel (Indoor)Type DCP as per technical specification 80 Wall mounted fans Approx. 400 mm sweep 81 Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator 82 Exhaust Fans 83 Fire Fighting System 84 DCP Type 85 i) 5 Kg. 86 ii) 10 Kg. 87 Carbon di oxide type – 6 Liters. 88 Foam Type- 9 Liters 89 Sand type 90 i) GI Buckets 9 liters capacity 91 ii) Steel Stands for four buckets 92 Air Conditioning System 93 Air Conditioning for the Rooms specified in the specifications 94 1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building] 95 Power Cables(XLPE) 96 3.5Cx300 sq.mm 97 Power Cable(PVC) 98 1Cx150 sq.mm 99 3.5Cx70 sq.mm 100 3.5Cx35 sq.mm 101 4Cx16 sq.mm 102 4C x 6 Sq. mm 103 2C x 6 Sq. mm 104 Control Cable (PVC) 105 4 CX4 Sq. mm 106 3Cx2.5 sq.mm 107 5Cx2.5 sq.mm 108 7Cx2.5 sq.mm 109 10Cx2.5 sq.mm 110 14Cx2.5 sq.mm 111 19Cx2.5 sq.mm 112 Substation Structures 113 Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]: 114 NON Standard Pipe supportStructure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe support structure as per specification requirements]: 115 Isolators 116 220 kV (3-Phase) (Horizontal DOUBLE BREAK) 117 1600A, 50KA, isolator with one E/S 118 Post insulators for above Isolator 119 1600A, 50KA, isolator without E/S 120 Post insulators for above Isolator 121 1600A, 50KA, isolator without E/S (TANDEM Type) 122 Post insulators for above Isolator 123 132 kV (3-Phase) (Horizontal DOUBLE BREAK) 124 1250A, isolator with one E/S 125 Post insulators for above Isolator 126 1250Aisolator without E/S 127 Post insulators for above Isolator 128 Switchyard Erection 129 Busbar & Interconnections 130 New Substation/ Switchyard 131 220 kV Switchyard Works: 132 Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/PorcelainLong Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 133 Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 134 Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays] 135 220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 136 Twin ACSR Zebra 137 Single ACSR Zebra 138 Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps,connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following: 139 220 kV DMT-type layout 140 Line bay 141 Transformer bay 142 Bus-Coupler 143 Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps,connectors, junction box including of all accessories etc. 144 132 kV Switchyard Works: 145 Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 146 Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays] 147 132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay),Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangementand specification requirements[ for 1 Bay] 148 Twin ACSR Zebra 149 Single Panther 150 Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV TransformerBay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps,connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following: 151 132 kV Main & Aux-type layout 152 Line bay 153 Transformer bay 154 Bus-Coupler 155 Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps,connectors, junction box including of all accessories etc. 156 LT Transformer connection with ACSR Panter conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors 157 Bus Post Insulators (BPI) 158 220 kV 159 132 kV 160 Earthing & Lightning Protection System 161 Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area 162 40 mm Dia MS Rod 163 40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven. 164 40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven. 165 40mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link 166 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works 167 75X12 mm GS Flat 168 50X6 mm GS Flat 169 Earth Enhancing Compound for treated pits as above and other requirement as per specification 170 Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat 171 Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats 172 Earth Wire for Shielding Protection of Switchyard 173 7/3.15 Galvenized Steel Wire 174 Earthwire tension clamps with D Shackle assembly 175 PG calmp to suit 7/3.15 mm GS earth wire 176 Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat 177 Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat 178 Lug to suit 7/3.15 mm earth wire 179 Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire 180 Bay Marshalling KIOSK 181 200 way (Stud Type Connectors) 182 AC Distribution Boxes (Outdoor Type) 183 Outdoor AC Distbibution Box (Double Front type) 184 Outdoor AC Distbibution Box (Single Front type) 185 Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building] 186 Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washersetc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works] 187 LT Switchgear 188 LT AC Main Panel 189 LT AC Distribution Board 190 Main Lighting Distribution Board 191 Emergency Lighting Distribution Board 192 220VDCDB 193 48V DCDB 194 PLCC EQUIPMENTS 195 220 kV, 0.5mH / 1250 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end. (Suspension Type) 196 132 kV, 0.2mH / 1000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end. (Suspension Type) 197 4 kHz to 16 Khz channel digital PLCC carrier terminal with digital protection coupler (DTPC), IEC 101& 104 data and 4W E&M speech applications 198 4 kHz to 16 Khz channel digital PLCC carrier terminal without digital protection coupler (DTPC), IEC 01& 104 data and 4W E&M speech applications 199 VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel) 200 Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level. 201 Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level. 202 HF Armoured Coaxial cable having 75 Ohms unbalanced impendance. 203 PLCC Electronic Private Automatic Exchange (EPAX) suitable for 32 subscribers lines and 16 tie lines with redundancy of critical cards. 204 Telephone Sets (Push Button Type) 205 10 pair Jelly Filled and armoured telephone cable with copper conductor of 0.63 mm 206 5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm 207 5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm 208 Print testing kit (for digital PLCC panel) 209 TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS 210 (A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements] 211 Insulation Tester (5000 Volts, Digital) 212 SF6 Leakage Detector 213 Digital Multimeter 214 Digital Clamp Meter 215 (B) Maintenance Tools& Tackles 216 Oil Sampling Bottle (1 Liter Capacity) 217 Vaccum Cleaner 218 Telescopic ladder aluminium 6 meter height 219 Ring spanner set 220 Tube spanner set 221 Pipe wrench 24 inch 222 Pipe wrench 18 inch 223 Hydraulic crimping tools up to 630 sq.mm 224 Threading die set for pipe threading 225 Welding machine (arc welding) 10kVA 226 Heavy duty drilling machine 227 Bench Vice 228 Insulated cuttingplier 12 inch 229 Insulated cuttingplier8 inch 230 Screw driver 18 inch 231 Screw driver 12 inch 232 Hammer 8 lbs 233 Hammer 2 lbs 234 Chain pulley block 5 ton 235 Pipe derrick 236 Allen Keys 237 Box Spanners 238 (C )Office and Miscellaneous Equipments/ Items 239 Insulation Rubber mat (1mX2mX 12 mm) 240 Isulation Rubber Gloves (33 kV Tested) 241 Furniturefor Control Room Building: 242 SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification 243 Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet) 244 Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet). 245 Library Shelf with Glass Door (min 4 Shelf) 246 Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane. 247 Archival Storage 4 Drive Type 248 Lateral Filing Cabinets 249 3 Drawer Unit 250 4 Drawer Unit 251 Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 252 Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system. 253 Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system. 254 Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage). 255 Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG. 256 Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage 257 Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round. 258 Key board (wooden) with Glass door 259 First Aid Box 260 Shock Treatment Chart [Laminated with Frame] 261 Safety Instruction Boards [ Laminated with Frame] 262 (D) Drinking Water Arrangement 263 Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr) 264 RO/ Water Purifier 265 Refrigirator (380 Lt.) 266 Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner] 267 Danger Plate [Size and Color etc. be got approved from owner] 268 MANDATORY SPARES 269 (A )Circuit Breakers 270 220 KV 271 (One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism. 272 Rubber gaskets, ‘O’ rings and seals 273 Fixed Contacts 274 Moving Contacts 275 Terminal pads and connectors 276 Closing Assembly Valve 277 Trip Assembly Valve 278 Auxiliary Switch Assembly 279 Operation Counter 280 Closing Coils 281 Tripping coils 282 Support insulator complete for one pole of breaker 283 145 kV 284 One pole of circuit breakerwithout support structure and operating mechanism. 285 Rubber gaskets, ‘O’ rings and seals 286 Fixed Contacts 287 Moving Contacts 288 Terminal pads and connectors 289 Closing assembly valve 290 Trip assembly valve 291 Auxiliary switch assembly 292 Operation counter 293 Closing Coils 294 Tripping coils 295 Support insulator (set complete for one pole of breaker) 296 Instrument Transformer 297 Spare of 245kVCapacitive Voltage Transformer 298 (i)Complete CVT 299 Spare of 145kVCapacitive Voltage Transformer 300 (i)Complete CVT 301 Spare of 245kVCurrent Transformer 302 (i)Complete CT [1 No. each type supplied) 303 Spare of 145kVCurrent Transformer 304 (i)Complete CT (1 No. each type supplied) 305 (E) C&R panels (similar items as used in the quoted panels) 306 Bay Control Unit (220 kV Side of offered type) 307 Bay Control Unit (132 kV Side of offered type) 308 Bay Control & Protection Unit (33 kV Side of offered type) 309 Bay Unit (For 220 kV Busbar Protection of offered type) 310 Bay Protection Unit (Distance for 220 kV Feeders of offered type) 311 Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type) 312 Bay Protection Unit (Distance for 132 kV Feeders of offered type) 313 Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I) 314 Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II) 315 Bay Protection Unit (Differential for 132 kV Transformers of offered type) 316 Bay Protection Unit (Back-up Overcurrent & E/F of offered type) 317 Breaker failure relay (numerical type) 318 Trip circuit supervision relay 319 Self reset trip relay 320 Hand reset trip relay 321 Timer relay 322 DC supervision relays 323 Flag relays 324 Auxiliary relays 325 Multifunction Panel Meter 326 Fiber Optic Cable with Connectors 327 Transducers (Each Type used in the autoamtion system) 328 Ethernet Switch (of offered type) 329 (F) Station Transformer 330 10% of total Transformer Oil quantity in non-returnable drums 331 HV bushing 332 LV bushing 333 Pressure relief device 334 Tap charger contact 335 Set of valves 336 Set of gasket 337 Silica gel required for five replacements 338 (G) Surge Arrester 339 220kV class 198 kV rating LA complete as specified. 340 132kV class 120 kV rating LA complete as specified. 341 2 Nos. Terminal connector of each type as spare 342 (H) Battery & Battery Charger 343 220 V& 48 V Type Battery 344 Spare battery cell without electrolyte 345 Terminal connectors with bolts & Nuts 346 Float level indicators 347 Vent Plugs 348 220V/ 50V Battery Chargers 349 Set of Control Cards 350 Set of relays 351 Set of contactor 352 Micro-switches 353 Filter Capacitors 354 Thyristor/ Diode 355 Set of switches 356 Set of wound resistors 357 Potentiometers 358 Fuses of Thyristor with indicators 359 (I) L.T. SWITCHGEAR : 360 Relays 361 CTs AND PTs 362 Switches/Push buttons and Meters 363 TPN Switches/MCB 364 L.T. Breaker spares 365 a) Spring charging motor 366 b) Aux. Contact sets 367 c) Busbar Seal off insulators 368 d) Arc-chutes 369 e) Moving contacts 370 f) Arcing contacts (Fixed/Moving) 371 g) Springs (Closing/Opening) 372 h) Closing coil 373 i) Tripping coil 374 j) Aux. finger contact 375 k) Limit switches 376 l) Jaw contacts 377 Busbar 378 a) Busbar insulators 379 b) Interphase barrier 380 c) Busbar strip 1mm (Aluminium) 381 (J) LIGHTING SYSTEM 382 Single Pole MCB 383 Triple pole MCB 384 Fluorescent tube & Starter 385 a) Choke 386 b) Bottom Strips 387 c) Top covers & reflector (if applicable) 388 d) Holders 389 e) Complete fittings 390 Sodium vapour/Mercury vapour Lamps a) Lamp 391 b) Ballast 392 c) Condenser/ Igniter 393 d) Lamp holder 394 e) Lamp holder 395 f) Complete fittings 396 Incandescent lamp 397 a) Bulbs 398 b) Holders 399 c) Complete fittings 400 Switches and sockets 401 Junction box 402 Celing Fan 403 (K) Clamps & Connectors Set 404 (M) Isolators 405 220 kV 406 Solid core Insulator Stacks (Requirement of one Isolator) 407 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 408 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 409 Motor with gear assembly and bevel gear assembly. 410 Bearings (Requirement of one Isolator) 411 Current carrying assembly total (Requirement of one Isolator) 412 132 kV 413 Solid core Insulator Stacks (Requirement of one Isolator) 414 Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered. 415 Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered 416 Motor with gear assembly and bevel gear assembly. 417 Bearings (Requirement of one Isolator) 418 Current carrying assembly total (Requirement of one Isolator) 419 Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
Contract Date: Feb 22, 2026 Contract Value : 52.23 Crore
Government Departments No of Bidders 5
24.
Chemicals and Fertilizers #9630312 AOC
Bids Are Invited For 1 SCR 3-PH. C. 208-480 V, 20AMP, JK3PS-48020 (c110V) DETAIL SPECIFICATIONS AS PER ATTACHED SHEET JK3PS48020 of JK OR EQUIVALENT 2 PVC REINFORCED HOSE PIPE SIZE 25 MM ID AND 34 MM OD PVC FLEXIBLE BRAIDED TRANSPARENT PIPE WORKING PRESSURE 11 KGF/CM2 3 Complete Ratchet Tool box of FORCE – 2462 1/4″ Socket set 46pc Description: Content- • 1/4″ 6pt. Flank socket 4; 4.5; 5; 5.5; 6; 7; 8; 9; 10; 11; 12; 13; 14mm • 1/4″ Socket bit Hex 3; 4; 5; 6; 7; 8mm • 1/4″ Socket bit Star T8; T10; T15; T20; T25; T30; T40 • 1/4″ Socket bit Slotted 4; 5.5; 7 mm • 1/4″ Socket bit Phillips PH.1; PH.2; PH.3 • 1/4″ Socket bit Pozidriv PZ.1; PZ.2; PZ.3 • 1/4″ Ratchet handle 24 teeth • 1/4″ Extension bar 2″; 4″ • 1/4″ Sliding T-handle • 1/4″ Flexible extension • 1/4″ Universal joint • 1/4″ Spinner 6″ • Hex key 1.27; 1.5; 2; 2.5 mm 4 Bench Type Drilling Machine (25 mm dia capacity) DRILLING RANGE IN STEEL 10 - 25 mm Diameter RANGE OF SPEED 60 -3000RPM 5 2.5 TON MAXIMUM CAPACITY PALLET TRUCK EQUIPPED WITH POLYURETHENE TANDOM ROLLERS SHALL WORK SMOTHER ON ROUGH SURFACE, WHEEL DIAMETER IS ABOUT 200 MM.AS PER FOLLOWING SPECIFICATIONS. 1) Weight= 70-90Kg. 2) MOC = Mild Steel. 3) Load capacity-2.5TONS. (Max.) 4) Lifting Height= 200-250mm. 5) Minimum Fork Height- 80-90mm 6) Fork Length-900-2000mm. 7) Outside Fork Spread- 550mm. 8) Inside Fork Spread- 230mm. 6 BOSCH MAKE INDUSTRIAL / PROFESSIONAL WET / DRY EXTRACTOR. MODEL- GAS 15L PROFESSIONAL. MAKE-BOSCH. SUPPLY VOLTAGE- 230VAC, 50HZ MAX. AIR FLOW - 62L/SEC. MAX. VACUUM PRESUURE - 215 MBAR. VACUUM CLEANER COMPLETE WITH ALL ACCESSORIES. 7 63A, FP, advance breaker, adjustable mA, tripping Siren- LED Light, Metal Body, SG FPS 63 Amp, adjustable leakage current for LDB Safetyguard or equivalent 8 Battery Analyzer BT100 Pro 12V 100-1100 CCA Battery Load Tester Detect regular flooded, Foxwell or equivalent 9 280 Pcs Electrical Cable Connectors Assorted for vehicle, Wire Crimp U-Type Fork Spade Butt Ring Connector Assortment Kit Male/Female Wire Cable Crimp Terminals -plastic box, TOOINKCV or equiv 10 165 Pcs vehicle blade Fuse Set Kit TC/ATM Car Fuses, Blade-Type Automotive Fuses - Standard & Mini Size (2A/3A/5A/7.5A/10A/15A/ 20A/25A/30A/35A/40A), Replacement Fuses for with plastic box , STHIRA or equivalent 11 IC kit 161 pcs assertment kit with op Amp,photo coupler, PWM controller 161 pcs 20 models, Each with individual compartment EEEEE/1A manufacturing or equivalent 12 Voltage Detector for vehicle check, Power Supply-Voltage Ckt Tester LED Probe, Diagnostic Tool, crocodile clamp connect lead length- 2M model- VT501 DC, Cat-III make KAIWEETS or equivalent 13 Display Board on different Diodes Model-CBD-706, make omega electronics, tesca or equivalent 14 Display Board on different Resistors and Colour Coding Model-CDB-701, make omega electronics, tesca or equivalent 15 Display Board on different Cables Model-CBD-709, make omega electronics, tesca or equivalent 16 Display Board on different Transistors Model-CDB-707, make omega electronics, tesca or equivalent 17 Display board on different ICs Model-CDB-713, make omega electronics, tesca or equivalent 18 Display Board on semicondor devices Model-CDB-708, make omega electronics, tesca or equivalent 19 Display Board on different Capacitors and Colour Coding Model-CDB-703, make omega electronics, tesca or equivalent 20 BATTERY DISCONNECTOR SOCKET IN PLASTIC ENCLOSURE SUITABLE FOR BATTERY OPERATED TRUCK WITH 36V, 295A BATTERY. 21 PORTABLE HAND HELD HOT AIR BLOWER. WITH TEMPERATURE CONTROLLER CONTINUOUSLY ADJUSTABLE - RANGE 50 TO 600 DEG. THREE STAGE AIR FLOW. WITH LCD DISPLAY.SUPPLY VOLTAGE 230VAC 50HZ. MAKE - RAYCHEM / STEINEL 22 RAYCHEM HEAT SHRINKABLE BUSBAR INSULATION TUBING BPTM. VOLTAGE CLASS - 25KV. PRODUCT CODE - BPTM-100/40-A/U-4 23 LED FLOOD LIGHT FITTING, 200W ± 5W, 230V AC, COOL WHITE, IP65, 4KV SURGE PROTECTED, LUMEN: MIN 100 LUMEN/WATT, TEMPERATURE RANGE: 5500-6500K, CRI- MIN 70 SQUARE SHAPE, BIS APPROVED, MAKE:SYSKA/ BAJAJ/EQUIVALENT MAKE 24 LED BASED OUTDOOR TYPE STREETLIGHT FITTINGS; WATTAGE: 120W +/-5W SUPPLY. VOLTAGE: 230V AC,50Hz,IP65, LUMEN: MIN 90LUMEN/WATT TEMPERATURE RANGE: 5500-6500K,CRI- MIN 70, 4KV SURGE PROTECTED LM80 CERTIFIED, CROMPTON/BAJAJ/ EQUIVALENT MAKE 25 LED TYPE WELL GLASS FITTING IN WEATHER PROOF IP65 ENCLOSURE, CONSTRUCTION- CAST AL LM 6 ALLOY, DOME-TOUGHENED CLEAR GLASS / POLYCARBONATE, WATTAGE-45+/-5W, SUPPLY- 230V AC, 50 Hz, 4KV SURGE PROTECTED, LUMEN: MIN 100 LUMEN/WATT, TEMPERATURE RANGE: 5500-6500K, CRI- MIN 70, LM80 CERTIFIED, CABLE ENTRY- SIDE ENTRY. EPOXY PAINTED, MAKE:SYSKA/ BAJAJ/EQUIVALENT MAKE 26 LED BASED INDUSTRIAL HIGH BAY LIGHT FIXTURE; WATTAGE 120+/-2W SUPPLY VOLTAGE 90 TO 270V AC WITH TECHNICAL SPECIFICATIONS AS PER SHEET MATTACHED. 27 EXHAUST FAN 380/400 MM SWEEP,WITH FOLLOWING SPECIFICATION: SPEED 900 RPM,RATED SUPPLY VOLTAGE: 240 V AC, FREE AIR DELIVERY (M3/HR)> 2400, POWER CONSUMPTION 90 WATTS.(1)TWO COATS OF EPOXY PRIMER OF 40 MICRON THICKNESS FOR PROTECTION AGAINST CORROSION & ACID FUMES.(2)DOUBLE BALL BEARING,DYNAMICALLY BALANCED BLADES.(3)INSULATION CLASS-E 28 METAL CLAD PLUGTOP AND SOCKET IN SHEET STEEL ENCLOSURE 250V,SINGLE, PHASE AC,3 PIN,20 AMPS SOCKET NEATLY WIRED WITH 2 POLE 16 AMP,30mA AFDD HAVING INTEGRATED MCB(16A) AND RCD(30mA), FEATURES HAVING SHORT CIRCUIT OVERLOAD,OVERVOLTAGE, EARTH FAULT AND ARC FLASH PROTECTION. MAKE:SCHNEIDER/ HAGER (L&T) /SIEMENS/ GE/ LEGRAND/ HAVELLS/ ANCHOR. 29 BLDC CEILING FAN, 1200mm SWEEP, 5 STAR of BEE, VOLTAGE: 230V, Frequency- 50 Hz, Air Delivery – minimum 210 CMM, Power Factor- 0.98, Double Ball Bearing, White color. WITH BIS CERTIFIED. As per technical specification attached. SUPPLY OF ENERGY EFFICIENT BRUSHLESS DIRECT CURRENT PEDESTAL FAN AS PER SPECIFICATION WITH REMOTE CONTROL AND MOUNTING HARDWARE. TECHNICAL SPECIFICATIONS ARE AS FOLLOWS. 1. BLADE SWEEP - 400 MM 2. FAN MOTOR - BRUSHLESS DIRECT CURRENT MOTOR 3. APPLICABLE STANDARD - IS 1169/1967 4. OPERATING VOLTAGE - 140 TO 285 VOLT, SINGLE PHASE AC 5. RATED FREQUENCY - 50 HZ +/- 5% 6. RATED POWER INPUT - 30 WATT MAXIMUM 7. RATED SPEED - Min. 1300 RPM 8. POWER FACTOR - 0.9 MINIMUM 9. RATED AIR DELIVERY - 75 CUBIC METER PER MINUTE OR BETTER 10. RATED SERVICE VALUE - 2.5 CU.M./MIN/WATT MINIMUM 11. NO. OF BLADES - THREE 12. SPEED CONTROL - a) REMOTE: 3 SPEED WITH BOOST & OSCILLATION MODE CONTROL , b) PUSH BUTTON OFF, ON& 3 SPEED, BOOST & OSCILLATION MODE 13. MOTOR BODY: PLASTIC 14. BLADE MATERIAL: POLYPROPYLENE 15. THD - < 5% 16. BEARINGS - DOUBLE BALL BEARINGS 17. WARRENTY - FIVE YEARS 18. MAKE -CROMPTON/BAJAJ/HAVELLS/ATOMBERG/SUPERFAN OR EQUIVALENT 19. COLOUR - WHITE 20. DOCUMENTS ALONG WITH THE BID - COPY OF TYPE TEST CERTIFICATE AS PER IS 1169/1967 FROM CPRI / ERDA / ERTL OR ANY NABL ACCREDITED FOR THE OFFERED PEDESTAL FAN ALONG WITH THE BID AND AT THE TIME OF SUPPLY OF MATERIAL. 21. VENDOR SHALL INDICATE ACTUAL INPUT POWER COMSUMPTION AND OTHER TECHNICAL DETAILS OF THE OFFERED FAN AS PER ATTACHED TECHNICAL DATA SHEET. THE PRICE EVALUATION OF TECHNICALLY APPROVED TENDERER SHALL BE CARRIED OUT AS PER ATTACHED PRICE EVALUATION SHEET. 300134101 SLIM LED DOWN LIGHT,12 + 1 WATT, 240V,6000K,CEILING RECESSED MOUNTING, DIFFUSER, LIFE MORE THAN 40000 HRS, MATERIAL ALLUMINIUM PC ALONG WITH DRIVER,CEILING CUTOUT DIA160 MM, OUTER SIZE 180MM AS PER ATTACHED SPECIFICATIONS. 300122281 DOUBLE T8,4 FT,2*18W, LED TUBELIGHT FITTING, IP65,WATER PROOF LED LAMP G13 HOLDER, MIN 3200 LUMEN, CRI ≥ 70. MAKE : SYSKA,BAJAJ, HAVELLS, PYROTECH, SUDHIR, C&S. MADE IN INDIA. 300129405 LED TUBE FITTING 4FT ALONG WITH LED TUBE LAMP 18W 1600 LUMENS.FULLY WIRED WITH SUITABLE CONNECTOR AS PER TECHNICAL SPECIFICATION ATTACHED 300127652 LED TUBE ROD 4 FOOT,T8, 230 V AC, 50 HZ,20w+/-2, BASE CAP G13 BI PIN, MINIMUM 1600 LUMENS, COOL WHITE TEMPERATURE RANGE: 5500-6500K,CRI- MIN 70, LM80 CERTIFIED, MAKE: CROMPTON/BAJAJ/ EQUIVALENT MAKE 300115070 PLUG TOP 3PIN, 15AMP, 250V ANCHOR MAKE. 300055295 36 PLUG TOP 3PIN, 5AMP, 250VOLTS, ANCHOR MAKE. 37 SWITCH SOCKET COMBINED 5AMP, 250 VOLTS, 5 PIN TERMINAL, MAKE ANCHOR , AS PER LATEST BIS STANDARD 38 5 AMP/ 15AMP SWITCH SOCKET COMBINED 6-PIN TERMINALS, 250VOLTS MAKE: ANCHOR OR EQUIVALENT, AS PER LATEST BIS STANDARD 39 PIANO TYPE SWITCH,IVORY OR WHITE COLOUR,ISI MARKED,RATING 5A, ONE WAY ANCHOR MAKE. 40 15AMP SWITCH, 250V AC, PIANO TYPE, ANCHOR MAKE OR EQUIVALENT WITH ISI MARK. 41 PENCIL CELL 1.5V SIZE: AAA DURACELL SPECIFICATIONS: 1. NOMINAL VOLTAGE: 1.5 VOLTS 2. REUSEABILITY: SINGLE USE (NON RECHARGEBLE ALKALINE BATTERIES) 3. DESIGNATION: ANSI 24A, IEC LR03 4. TERMINALS : FLAT 5. CAPACITY: 1000 mAh 6. COPPERTOP SERIES MN2400 7. MAX.OPERATING TEMP: -20 DEG C to 54 DEG C 8. BATTERY CELL COMPOSITION:ALAKALINE 9. LEAKPROOF BATTERIES AND METAL JACKET INSULATION 10. MAKE: DURACELL 11. VALIDITY: DATE AND YEAR OF MANUFACTURING ALONG WITH EXPIRY SHALL BE CLEARLY PRINTED ON EACH UNIT/ PACKAGING 12. NOTE: MANUFACTURING DATE OF MATERIAL SHOULD BE WITHIN 6 MONTHS FROM THE DATE OF SUPPLY/ DELIVERY 42 PENCIL CELL 1.5V SIZE: AA DURACELL SPECIFICATIONS: 1. NOMINAL VOLTAGE: 1.5 VOLTS 2. REUSEABILITY: SINGLE USE (NON RECHARGEBLE ALKALINE BATTERIES) 3. DESIGNATION: ANSI 15A, IEC LR6 4. TERMINAL : FLAT 5. CAPACITY: 2850 mAh 6. COPPERTOP SERIES MN1500 7. MAX.OPERATING TEMP: -20 DEG C to 54 DEG C 8. BATTERY CELL COMPOSITION: ALKALINE 9. LEAKPROOF BATTERIES AND METAL JACKET INSULATION 10. MAKE: DURACELL 11. VALIDITY: DATE AND YEAR OF MANUFACTURING ALONG WITH EXPIRY CLEARLY PRINTED ON EACH UNIT/ PACKAGING 12. NOTE: MANUFACTURING DATE OF MATERIAL SHOULD BE WITHIN 6 MONTHS FROM THE DATE OF SUPPLY/ DELIVERY 43 BATTERY FLAT 9 VOLT OF MAKE DURACELL/ENERGIZER. 44 DIGITAL CLOCK TIMER L&T MAKE, CAT ID 67DDTO, 110-240VAC, 50 HZ CONTACT- 1 C/O. 16A (NO) AND 5A (NC) FOR STREET LIGHT / EQUIVALENT 45 CAPACITOR 2.5 MFD, +_5%, 440VAC, 50HZS, SUITABLE FOR CEILING FAN, MAKE: EPCOS/ BAJAJ/ CG/ KELTRON 46 CAPACITOR 4 U F 250 V AC MAKE: ASIAN/UNISTAR 47 CONDENSER 10MFD 10CM CONG BY 4.5CM DIA(FOR H P M VLAMPS.) WITH 4 LONG FLEXIBLE PVC INSULATED COPPERLEADS SOLDERED TO THE TERMINALS. MAKE: UNISTER GEC / ASIAN. 48 SINGLE CORE MULTI STRANDED COPPER CABLE BLACK SIZE 0.75 SQ MM PVC/XLPE INSULATED BLACK COLOUR 1100V GRADE AS PER LATEST BIS STANDARD WITH ISI MARK. 49 BAKELITE FUSE HOLDER WITH 2 AMP GLASS FUSE OF 30 X 5 MM SIZE. PVC INSULATED 1.0 SQMM CU STRANDED FLYING LEADS OF 100 MM LENGTH ON BOTH SIDES. CAP SHALL HAVE FUSE GRIP CLAMP 50 PVC SWITCH BOARD, IVORY OR WHITE COLOR, SIZE 8 X 10, MAKE: PRESTOLEPLAST OR EQUIVALENT, AS PER LATEST BIS STANDARD 51 SINGLE CORE MULTI STRANDED COPPER CABLE SIZE 1.5MM PVC/XLPE INSULATED RED COLOUR 1100V GRADE IN 100 METER LONG ROLLS AS PER LATEST BIS STANDARD WITH ISI MARK. 52 SINGLE CORE MULTI STRANDED COPPER CABLE SIZE 1.5MM PVC/XLPE INSULATED BLACK COLOUR 1100V GRADE IN 100 METER LONG ROLLS AS PER LATEST BIS STANDARD WITH ISI MARK. 53 SINGLE CORE MULTI STRANDED COPPER WIRE SIZE 1.5MM PVC/XLPE INSULATED GREEN COLOUR 1100V GRADE IN 100 METER LONG ROLLS AS PER LATEST BIS STANDARD WITH ISI MARK. 54 SINGLE CORE CABLE, MULTI STRANDED COPPER CONDUCTOR, SIZE 2.5 SQMM, PVC/XLPE INSULATED, RED COLOUR, 1100V GRADE, IN 100 METER LONG ROLLS, AS PER LATEST BIS:694 STANDARD WITH ISI MARK. 55 SINGLE CORE CABLE, MULTI STRANDED COPPER CONDUCTOR, SIZE 2.5 SQMM, PVC INSULATED, YELLOW COLOUR, 1100V GRADE, IN 100 METER LONG ROLLS, AS PER LATEST BIS:694 STANDARD WITH ISI MARK. 56 SINGLE CORE CABLE, MULTI STRANDED COPPER CONDUCTOR, SIZE 2.5 SQMM, PVC/XLPE INSULATED, BLACK COLOUR, 1100V GRADE, IN 100 METER LONG ROLLS, AS PER LATEST BIS:694 STANDARD WITH ISI MARK. 57 PVC INSULATED MULTISTRAND COPPER FRLS WIRE OF FOLLOWING SPCIFICATION SIZE-2.5 SQMM, COLOUR GREEN ,MAKE- ANY REPUTED MAKE 58 PVC INSULATED MULTISTRAND COPPER FRLS WIRE OF FOLLOWING SPCIFICATION SIZE-2.5 SQMM, COLOUR BLUE ,MAKE- ANY REPUTED MAKE 59 NYLON CABLE TIE NON RELEASABLE TYPE FOR CABLE DRESSING COLOUR - NATURAL WHITE PACK OF 100 PCS SIZE - 2.5 MM(WIDTH) X 75 MM (LENGTH) 60 NYLON CABLE TIE NON RELEASABLE TYPE FOR CABLE DRESSING COLOUR - NATURAL WHITE PACK OF 100 PCS SIZE - 2.5 MM(WIDTH) X 100 MM(LENGTH) 61 NYLON CABLE TIE NON RELEASABLE TYPE FOR CABLE DRESSING COLOUR - NATURAL WHITE PACK OF 100 PCS SIZE - 3.6 MM(WIDTH) X 150 MM(LENGTH) 62 NYLON CABLE TIE NON RELEASABLE TYPE FOR CABLE DRESSING COLOUR - NATURAL WHITE PACK OF 100 PCS SIZE - 4.7 MM(WIDTH) X 200 MM(LENGTH) 63 NYLON CABLE TIE NON RELEASABLE TYPE FOR CABLE DRESSING COLOUR - NATURAL WHITE PACK OF 100 PCS SIZE - 4.7 MM(WIDTH) X 300 MM(LENGTH) 64 TELEMECANIQUE FRANCE MAKE DOL MOTOR STARTER TYPE: LE1-M35N722, SUITABL E FOR 7.5KW/10HP, 415V MOTOR, COIL VOLTAGE:415V AC, OVERLOAD RANGE:12- 16A, DEGREE OF PROTECTION:IP 65, STARTER LOCATION:OUTDOOR 65 M/S SIEMENS MAKE DOL STARTER IN S.S HOUSING FOR 15KW MOTOR RATING 415VOLT ,3PHASE,50HZ,COIL VOLTAGE 415,TYPE 3TW04 94-2A 66 DOL Starter in S.S.housing WITH BI-RELAY FOR 1HP MOTOR,3PH,430V,50HZ CODE:3TW72911A.68 67 DOL Starter in S.S.housing WITH BI-RELAY FOR 3HP MOTOR,3PH,430V,50HZ CODE:3TW72911A.72 68 DOL Starter in S.S.housing WITH BI-RELAY FOR 3HP MOTOR,3PH,430V,50HZ CODE:3TW72911A.74 69 TUBELIGHT FITTING HOLDERS MAKE:ANCHOR/VINAY/LEADER 70 •INDUSTRIAL HEAVY DUTY WALL FAN (AIR CIRCULATOR) •SWEEP: 450MM (18 INCH) •SUPPLY VOLTAGE: 1 PHASE, 230VAC,50HZ •POWER CONSUMPTION: 100WATT +/- 10% •SPEED (RPM): 1440 •AIR DELIVERY 150 M3/MIN •NO. OF BLADES: 03 •NO OF SPEED: 03 •VERTICLE ADJUSTABLE •ALUMINIUM ALLOY ONE PIECE BLADE •DOUBLE BALL-BEARING 90 DEGREE OSCILLATION •STURDY CLOSE-MESH GUARD BEAUTIFUL DESIGN •POWERFUL HEAVY-DUTY MOTOR •MAKE- ALMONARD/CG/BAJAJ/USHA OR EQUIVALENT 71 •HEAVY DUTY INDUSTRIAL FAN (MAN COOLER) •SWEEP: 600MM (24 INCH) •SUPPLY VOLTAGE: 1 PHASE, 230VAC,50HZ •POWER CONSUMPTION: 500 Watt +/- 10% •SPEED (RPM): 1440 •AIR DELIVERY 10 TIMES BLADE SWEEP: 28000 M3/Hr. •ALUMINIUM ALLOY ONE PIECE BLADE •DOUBLE BALL-BEARING •STURDY CLOSE-MESH GUARD BEAUTIFUL DESIGN •POWERFUL HEAVY-DUTY MOTOR •MOUNTED ON THE STURDY MS PIPE SUPPORT AND WITH SOLID BASE. •MAKE-ALMONARD/CG/BAJAJ/USHA OR EQUIVALENT 72 FLAMEPROOF LED WELLGLASS LIGHT FITTING WITH INTEGRAL DRIVER AND LAMP, EX- d,HAZ. AREA ZONE 2 GAS GROUP-IIC , CIMFR AND CCE/PESO APPROVAL TO BE FURNISHED, RATING -230V AC, 50 HZ,45 WATT ± 5 WATT COOL WHITE5000K, OUTPUT MINIMUM 4500 LUMENS, IP66, MOC: CAST AL LM-6, CABLE ENTRY: 2 OF M20X1.5P WITH EX-D IIC PLUGS, EPOXY PAINTED, WITH SUITABLE CABLE ENTRY GLANDS Total Quantity : 1916
Contract Date: Ref. Documents Contract Value : 23.42 Lakh
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
25.
Public Administrative Department #9577760 AOC
Exterior Rustic Paint And Other Misc.Work At State Election Commission Building, Bhopal; 1 15.2.1 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge Cu M 85 578 49130 2 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure asInstructed by Engineer-in-Charge. sqm. 152 120 18240 3 15.6.3 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with in 50 metres leadas per direction of Engineer-inCharge. Cu M 46 487 22402 4 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors / walls and roofs laid in cement mortar including stacking material within 50 metres lead.Dementling tiles a 15.11.1 For thickness of tiles 10 mm to 25 mm. Sq M 454.29 17 7723 b 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. Sq M 210.00 26 5460 5 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of EngineerinCharge. Cu M 90.00 844 75960 6 15.14 Dismantling doors, windows and clerestory indows (steel or wood) shutter including chowkhats, rchitrave, holdfasts etc. complete and stackingwithin 50 metres lead : 15.14.1 Of area 3 sq. metres and below each 30.00 85 2550 7 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. each 30.00 223 6690 8 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. A 1.2.1 Lime, moorum, building rubbish beyond 5km up to10 km per km Cu M 180 53.43 9617 9 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. P.SQM 778 8.7 6769 BRICK WORK & PLASTER WORK 10 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) SQM 56 673 37688 ESTIMATE NAME OF WORK :- The Work Of Exterior Rustic Paint & Other Miscellaneous Work At State Election Commission Building, Bhopal. PAC-84,23,000 Time-06 Month 11 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. SQM 56 127 7112 12 13.3 20 mm cement plaster of mix : After grouting 13.3.1 1:4 (1 cement : 4 sand) sqm 98.2 245 24059 13 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) sqm 32.2 210 6762 RCC,PCC & CEMENT CONCRETE WORK 15 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil cum 50.00 147 7350 16 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-20 – Grade concrete cum 12 4933 59196 4.1.1.2 M-15 – Grade concrete cum 11.2 4471 50075 17 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. cum 25 672 16800 18 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. A 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 45.20 330 14916 B 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of deshuttering and decentering at alllevels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 20.52 2560 52531 19 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for MechanicalSplices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 52 80 4160 20 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. cum 7.20 6541 47095 21 2.39 Providing and laying of permanent piping technology antitermite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30cm interval in the tube, having working pressure of 2 kg/cm2 and release rate of 1.9 ltr/hour fixed by P-clips and nails. The LLDP pipe shall be installed at the entire periphery of the building and atnternal network of building at a depth of 20 to 200 mm under floor at every 2 to 3 mtr. c/c distance (adjusted as per building layout) & Ends of loop pass i through a PVC elbow of minimum 32mm ID at junction box of wall and floor level, entering into a steel reinforced grooved flexible pipe of minimum 22 mm ID leading into Junction box and the loops shall terminate in junction boxes & test every junction during injecting chemicals for termite control treatment. The antitermite chemical Imidacloprid 30.5% SC mix as per IS6313, (part III) shall be injected by the pressure pump diluted with water @ 10.5ml/5 ltr of water at the rate of 2 kg/sq.cm. @ 5Ltr/SMT. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineerincharge with bond of 5 year warranty. 2.39.2 Anti-termite chemical injected area sqm 602 53 31906 Water proofing 22 14.87 Providing and inserting 12mm dia galvanised steel injection nipplein honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mmto 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of EngineerIn-Charge Each 50 136 6800 23 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight ofapproved grout injected.) 14.83.3 Epoxy injection grout in concrete / RCC work of approved make Kg 20.2 658 13292 24 22.14.1 Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) Cu M 8.2 6569 53866 25 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh andSealer coat at leakage/ seepage area consisting of (i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). 22.22 (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hightbuild elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air curefor 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) Sq M 325.2 465 151218 26 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). SQM 120.2 597 71759 27 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, alconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water sqm 120 885 106200 FLOORING & GRANITE 28 11.3 Providing and laying gang saw cut 18 mm thick,mirror polished premoulded (wherever required)and pre polished machine cut granite stonework in flooring of required size shape of approved shade,color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-inCharge 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals ofother colors of glitter sqm 103.2 2642 272654 29 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser, dado and wall lining laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11.83.1 For skirting, riser, dado and wall lining etc. glossy/ rustic /stain/mattfinished in all colours and shades a 11.83.1.2 Size 600X600 mm thickness 9-10 mm sqm 120.2 1129 135706 b 11.83.1.4 Size 600X1200 mm thickness 11-12mm SQM 130.2 1224 159365 FITTING & SANITARY 30 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer inCharge. 18.6.2 Concealed work including cutting chases and making good the walls etc. A 18.6.2.1 15 mm nominal outer dia .Pipes. MTR. 75.3 207 15587 B 18.6.2.2 20 mm nominal outer dia .Pipes. MTR. 45 234 10530 c 18.6.2.3 25 mm nominal outer dia .Pipes. MTR. 29 288 8352 31 18.13 Providing and fixing CPVC gate valve with knob of approved quality. A 18.13.1 25 mm nominal bore EACH 6 428 2568 32 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) A 17.58.1 75 mm diameter MTR. 35 136 4760 B 17.58.2 110 mm diameter MTR. 35 238 8330 33 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. A 17.59.1 Coupler I 17.59.1.1 75 mm EACH 7 117 819 II 17.59.1.2 110 mm EACH 8 154 1232 C 17.59.3 Single tee with door I 17.59.3.1 75x75x75 mm EACH 7 219 1533 II 17.59.3.2 110x110x110 mm EACH 8 346 2768 E 17.59.5 Bend 87.50 I 17.59.5.1 75 mm bend EACH 7 117 819 II 17.59.5.2 110 mm bend EACH 8 172 1376 33 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) meter 15 1232 18480 34 19.7 Providing and fixing squaremouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.2 150 x 100 mm size P type 19.7.25.2 With sewer bricks conforming to IS : 4885 each 3 1707 5121 35 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand)finished with a floating coat of neat cement and making necessary channels for the drain etc. complete 19.23.1 For pipes 250 to 300 mm diameter each 21 292 6132 36 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.2.1 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 5 17402 87010 37 25.1 Providing and fixing white vitreous china Anti germ FluoroPolymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) EACH 3 4726 14178 38 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) EACH 2 26412 52824 39 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with sensotronic concealed type flushing valve battery & electricaloprated type (9V transformer) for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 2 23927 47854 40 25.8 Providing and fixing white vitreous china type Anti germ fluoropolymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flange and spout complete (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete 25.8.1 Providing and fixing white vitreous china type Anti germ fluoropolymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) EACH 2 14543 29086 41 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) EACH 6 2071 12426 42 25.2 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) EACH 5 1573 7865 43 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) EACH 5 2687 13435 44 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.2 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) EACH 5 1818 9090 45 17.61 Providing and fixing UPVC trap ofself cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet EACH 7 517 3619 46 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. EACH 11 74 814 47 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SQM 5.2 2440 12688 48 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank LTR. 1000 7 7000 49 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) EACH 5 2167 10835 50 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall ofstandard shape with bracket of the same material with all fittings etc. of approved quality and conforming toIS: specification. EACH 3 1175 3525 51 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) EACH 3 1354 4062 Aluminum windows 52 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately) sqm 11.55 4958 57265 53 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-incharge of approved brand and make. sqm 11.55 448 5174 54 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 303.2 416 126131 55 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) sqm 149.5 948 141726 56 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides sqm 65.5 1334 87377 PANNELING 57 9.15 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-in charge. (Frame work shall be paid for separately) 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 10 1210 12100 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 12 1320 15840 58 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.2 1.0 mm thick. sqm 22.2 691 15340 CEILING 59 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.3 12.5mm thick moisture resistant gypsum plaster boards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII SQM 55 920 50600 60 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. SQM 45.2 1431 64681 TEXTURED EXTERIOR PAINT 61 13.51 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. sqm 5229.8 650 3399370 INTERIOR PUTTY & PAINT 62 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete SQM 3140.8 5 15704 63 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. SQM 3140.8 24 75379 64 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required. SQM 1520 74 112480 65 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work SQM 3181.6 64 203622 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. sqm 125.26 53 6639 S.SLETTER & SIGNAGE 66 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes elding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-inCharge. per letter per cm height 1080 75 81000 STEEL & FABRICATION WORK 67 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 9.43.1 Fixed to steel windows by welding. kg 352.2 119 41912 68 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes kg 355.2 117 41558 69 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener,clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding inproper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PU paint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) sqm 25.6 9347 239283 70 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. metre 12.24 3234 39584 71 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SQM 18.12 652 11814 72 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design 5.23.2 Stainless steel Grade 304 plate-1.0 mm thick 5.23.2.1 150 mm wide. RM 164.52 367 60379 73 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 81.25 105 8531 PAVER BLOCK 74 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks,lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658- 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting andproper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in- Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 1950.00 805 1569750
Contract Date: Jan 02, 2026 Contract Value : 84.23 Lakh
Local Bodies No of Bidders 2
Madhya Pradesh View Result →
26.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
28.
Agriculture #9519259 Technical Bid
Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
29.
Defence #9509529 AOC
Tender For Repair/Maintenance Of Fire Hydrant System At Mil Stn Kota; 1 S&F in renewal of MS flanged pipe of 100mm nominal bore, heavy duty, for multistorey building duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete all as specified and directed. 2 S&F in renewal of Butterfly valve, 100 mm dia bore, heavy duty with CI body, liver operated IS-13095 marked including jointing materials i.e rubber gaskets, nuts, bolts etc complete all as specified and directed. 3 S & F in renewal of 3 phase contactor of suitable size and as per site requirment for pump motor of any capacities starters complete all as specified and directed. 4 S&F in renewal of existing single phase preventer complete all as specified and directed. 5 Supply only rubber gaskets for flanged joint superior quality for 100 mm dia flanges pipe complete all as specified and directed. 6 Dismantling carefully the AC electric motors of capacity upto 12.5 HP induction type, three phase, from the foundation, cutting down and removing the old burnt winding wire from the motor unit,rewinding the same with new super enameled copper winding wire as per existingsize/gauge of wire, providing necessary insulation by varnishing and drying the same upto specific temperature of heat, replacing insulation paper sleeves with connecting insulating material, tapping and providing necessary connection to the motors assembly reinstalling, commissioning and testing the pumping set upto good working performance complete all as specified and directed. 7 M & L for metal filling, welding, turning cutting, preparing the centrifugal pump/jockey pump shaft uptostandard size including hardening smoothing etc and bearing housings NDE andDE side, including checking & servicing of impeller and making pump fully functional for 440 volt 3 phase 50 Hz 35 M head 54 cubmetre per hr discharge complete on lath machineasper site requirement complete all as specified and as directed. 8 Supply only in renewal of following spare parts of existing make for centrifugal pump capacity upto 12.5 HP for srl item No 7.00 (here-in-before) : -Inter staging rings (Set of two Nos) 9 Inter casing rings (Set of two Nos) 10 Bushes Gun Metal 11 BearingNDE/DE 12 Motor terminal plate having Nuts and bolts studs. 13 Shaft sleeves mild steel. 14 Coupling set with nut bolt and washer. 15 S&F in renewal of Star-Delta Starter with sheet enclosure outdoor type 3mm thickof suitable size for 12.5 HP capacities motor in existing location incl making electric connections with PVC insulated 1100 volts grade single core multi stranded copper conductor complete all as specified & directed. 16 S&F in renewal of cast iron non return valve ball type, heavy duty both ends flanged drilled holesincluding two nos of flanged ends including 2 flanged joints and jointing material i.e. nuts, bolts, washers, rubber gaskets etc of size 100 mm dia NRV complete all as specified & directed. 17 M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old unserviceable earthing complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately). 18 M & L for repair of Non return valvevalve alongwith its gasket & connected accessories upto 100 mm dia complete all as specified and directed. 19 M & L in renewal of worn out MS sheet portion of hose window framelocated at shaft of building using 18 SWG MS sheetdouble door& fixing of glass in replacement of brokenwith 4 mm thick glasses including painting of MS sheet with fire red outside and brilliant white inside complete all as specified and directed. 20 S & F in renewal of Hose reel drum for upto length 36 m, ISI Marked complete all as specified and directed. 21 M & L for painting MS pipe 100 mm dia, hose reel drum & metallic accessorieswith two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete al as specified and as directed. Note :- Cost of T&P required for painting fire structure shall be included in the rate quoted. 22 M & L for welding, cleaning and any other minor repairrequired for smooth functioning ofAir Cushioin Tank/Air vessel upto 400 mm dia & upto 1500 mm high with dished top, made of minimum 6 mm thick MS Pipe/Plate complete including replacement (if required) of stop valve, pressure gauge and all accessories as per existing arrangement required including mounting bracket complete all as specified and as directed. ` 23 Attending complaints to pump & motors by qualified mechanic to check and test DOL/star-delta starter connections including settings of relay and timer, NO & NC contacts, main power connections, fixing of cable joints,fixing gland packing of approprate size to the pump motors, rectifying pump leakages alongwith pipe line leakges then welding, filling the leakage/gap including replacing flange, rubber packing and nut bolts of existing size and cleaning of pump motors to confirm the satisfactory running with replacement of following items. The cost of minor spares such as lugs of all size, wires, nut, bolts, washer, Flanges, rubber packing, gland packing, cable joints etc are included in quoted rate bycontractor.Note:-Repair to defects after informing within 24 hours, in case of failure noticed more than 24 hrs recovery shall be effected @ Rs.500/- per hour beyond 24 hrs. 24 Supply and fixing in renewal of hose reel of 20 mm innerdia and 30 meter length complete all as specified and as directed. 25 Supply and fixing in renewal of branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 (one FHC each floor) complete all as specified and as directed. 26 Providing and fixing in renewal of High Pressure – 10L Water Mist And CAF Fire Extinguisher Constant operating pressure of 34 bar with negligible recoil, Light weighted gun of 750 grams, Suitable for Class A, Class B and Live Electrical Fire, Ý System suitable for 35 KV as per EN 3 standard & 36 KV as per IS:15683:2006, Backpack and Hand Held System, Light weight anti corrosive aluminum alloy vessel/ CFRP - Carbon.,Fiber Reinforced PolymerPressure gauge on the vessel as per EN 3 standard cmplete all as specified and as directed. 27 Providing and fixing in renewal of 6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged complete all as specified and as directed. 28 Providing and fixing in renewal of CO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete all as specified and as directed. 29 Supply, installing, testing and commissioning in renewal of microprocessor based Single-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel equipped with sufficient numbers of loops considering 10% spare capacity in each loop. Each loop shall have a capacity of minimum 399 analog addressable devices. 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories, wires, circuits, fasteners, clamps etc., complete all as specified and as directed with following specifications :- • Features & Benefits: Optional 40 or 80 zone alarm LEDs, Easy 5 key-press set-up, Large blue LCD display, Supports USB upload/download, Battery backed real-time clock (2 & 4 loop), 2 independent sounder circuits 500mA, multi-protocol loop driver, PC configuration software (supplied with panel), Sensitivity adjustment e.g. between day and night Input/output logic, Indicators: Fire, Fault, Disablement, Test, Buzzer Muted, Delayed Mode, Sounders Silenced, Sounders Disabled and Power. Also dedicated fault LEDs for System Fault, Sounder Fault, Supply Fault and Earth Fault. (F)Loop Capacity: 500mA per loop(G) NUMBER OF DEVICES CONNECT:Total number of devices 399 (199 NOS. MCPs, Modules & AV product + 200 SENSORS)MAKE: HONEYWELL MORELY- IAS DX MODEL-DXC4 (Networkable multi-protocol, analogue addressable fire alarm control panel). 30 Supply, installing, testing and commissioning in renewal of Sounder cum Strobe (Hooter) rated at 75 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. Wall Mount Sounder by KAC’s base sounder, high quality loop powered device designed to alert building occupants of an emergency. It utilizes the System Sensor B501AP base for improved installation flexibility and integrates seamlessly with SS intelligent detectors. Triggered by the fire panel its powerful sounder gives an audible warning. A choice of output levels and tones make the device suitable for a wide variety of applications., complete all as specified and as directed with following Features & Benefits:- -Reduced install errors and easy fault finding-Reduced full life costs-Excellent system performance-Reduced inventory countCertifications:• EN54-3• VdS• LPCB 31 Supply, installing, testing and commissioning in renewal of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device.UL and FM ApprovedInstallation efficiency, compliance with the latest standards are at the heart of the call point range LED Status The LED status is controlled by fire panel and shows blinking RED each time the device is polled, or continuous RED to indicate fire complete all as specified and as directed with following :- FEATURES & BENEFITS• Unique ‘Plug & Play’ installation concept • Analogue addressable communications • Fully compliant with EN54, Part 11 • Integral LEHM-MCP-GLASS SPECIFICATIONS MECHANICAL Dimensions Semi-flush mounting: 89 x 93 x 27.5 (WxHxD) Surface mounting : 89 x 93 x 59.5 (WxHxD) Weight IP Rating Operating Temperature Relative Humidity: 110g IP24D 0°C to 49°C 10% - 93% non condensing PART NUMBERS HM/MCP/GLASS Addressable break glass manual call point Operating Voltage 15V to 32Vdc max Current Consumption Quiescent: 385µA Alarm Current: 7.8 mA With TEST KEYS. 32 Supply, installation, testing & commissioning in renewal of HPSR 2C x 1.5sq.mm. MICA taped fire survival cable insulated overall shielded BASEC & LPCB certified cable conforming to BSL7846 & BS6837 CWZ, BSEN 50200. The cable shall withstand 950 degree centigrade for 3 hours conforming to BSL6387 standard with mounting accessories required for mounting & tagging with clamps, plastic pipes, fasteners and all accessories. (FOR Fire Alarm and Detection System) complete all as specified and as directed.MAKE: POLYCAB/KEI/RR. 33 Supply, installation, testing & commissioning in renewal of FIRE SIGNAGES for indication / information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts etc of size 12×4inches complete all as specified and as directed. 34 Supplying and fixing in renewal of Stainles Steel Single headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required complete all as specified and as directed & as per approved by GE. (Make -Safex) 35 Supplying and fixing in renewal of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of canvass (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with GI rivets and GI wire etc. as required. Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted., complete all as specified and as directed & as per approved by GE. (MAKE-SAFEX) 36 Supplying & fixing in renewal of SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes complete all as specified and as directed & as per approved by GE. (MAKE- SAFEX) 37 Supplying and fixing in renewal of Single Door Hose Box Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 1 Nos 15 Mtr.Long RRL Hose and 1 NoS. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) complete all as specified and as directed & as per approved by GE. (MAKE-SAFEX) 38 Supply and fixing in renewal of water pressure gauge 0-300 Psiincl necessary valves reducers and nipple pipe as per existing complete all as specified and directed. (Make: H-Guru) 39 Supply, installation, testing & commissioning in renewal of Pressure switch For auto start/OFF of fire hydrant system complete all as specified and directed. (Make: DANFOSS) 40 S & F in renewal of feeder pillar box of outdoor type fabricated out of 3.0 mm thick CRCA sheet double door (front & back opening),CPRIapprovedcomplete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd complete all as specified and directed with the following:-(a) Aluminium bus bar 400 Amp (R Y B & N) with colouredheat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) MCCB FP 250 Amps, 415 V, 25 KA- 01 No for main in coming (c) MCCB FP 100 Amps25 KA- 02(d) MCCB FP 63 Amps25 KA- 02(e) MCB SPN 6-32 A 10 kA-01 Nos(f) LED indicator for RYB of size 22.5 mm- Set of 3(g) Multifunctional meter forfreq, power factor, amperes, voltage etc.- 01 setNote: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging. 41 S& F in renewal of feeder pillar box of outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening),CPRIapprovedcomplete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd complete all as specified and directed with the following:-(a) Aluminium bus bar 400 Amp (R Y B & N) with colouredheat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) MCCB FP 160 Amps, 415 V, 25 KA- 01 No for main in coming(c) MCCB FP 100 Amps25 KA- 02(e) MCB SPN 25 A 10 kA-02 Nos(f) LED indicator for RYB of size 22.5 mm- Set of 3(g) Multifunctional meter forfreq, power factor, amperes, voltage etc.- 01 setNote: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging.
Contract Date: Feb 09, 2026 Contract Value : 35.13 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
30.
Housing Urban and Rular Development #9488962 Technical Bid
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
31.
Housing Urban and Rular Development #9475738 Technical Bid
Tender For Construction Of Administrative Block Cyber Thana At Ambedkarnagar -Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavation in foundation in ordinary soil (loam clay or sand) inluding lift upto 1.5 metres and lead upto 30 metres & including filling, watering & ramming of excavated earth into the trenches or into the spacebetween the buildings & the sides of foundation trenchesor into the plinth and removal & disposal & surplus earth as directed by the Engineer-in-charge upto a distance of30 m from the foundation trenches 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping eFoundations, footings, bases of columns, etc. for mass concrete.tc. and removal of form for all heights : 10 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. : 11 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 12 Columns,Pillars, Piers, Abutments, Posts and Struts. 13 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 14 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 16 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 19 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :R.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete) 20 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. columns in 1:1.5:3 having strength not less than M-20. 21 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 23 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 24 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 28 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 29 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 30 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 31 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 32 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 33 Supply & fixing of flush Doors commercial quality Conforming to 1.S. 2202 Part I (1983) Including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges. Bolts locks, handles,springs. Fitting with necessary screws to be supplied departmentally. 35 mm thick 34 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 37 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 38 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 39 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 40 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 41 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 42 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning (b)Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. the surface beforetreatment.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 43 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 44 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 45 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 46 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 47 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 12 mmthickcementplasterindado/ skirting in 1:3 consisting of one part of cement and 3 partsof aprovedcoarsesand laid inpanels,finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required forpropercompletionofthe work. 51 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) laid in one layer finished with a floating coats neat cement (40 mm thickfloor). 52 Making groove 10x12 mm widex 8 mm deep in plaster of the wall or in ceilling vertically or horizontally as required AND .Add for groove in plastered surface or moulding to R.C.C. projections 53 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 54 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 55 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] 56 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 57 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm 58 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 59 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 60 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 61 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 62 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 63 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 64 ainting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 65 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 66 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 67 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 68 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 69 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 70 Coupler 110 mm 71 Bend 87.5° 110 mm bend 72 Shoe (Plain) 110 mm Shoe 73 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 74 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. 75 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 76 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 77 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 78 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 79 For vertical surface two coats @ 0.70 kg per sqm 80 For horizontal surface one coat @1.10 kg per sqm. 81 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 82 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 83 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 84 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank 85 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 86 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 87 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 88 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 89 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 90 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 91 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 92 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 93 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 94 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 95 90 mm O.D. 96 110 mm O.D. 97 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 98 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 99 90 mm size 100 110 mm size 101 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 102 75 mm Shoe 103 110 mm Shoe 104 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 105 90x90x90 mm size 106 110x110x110 mm size 107 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 108 90 mm size 109 110 mm size 110 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 111 90 mm size 112 110 mm size 113 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 114 90 mm size 115 110 mm size 116 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 118 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 119 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 120 20 mm nominal outer dia pipes 121 25 mm nominal outer dia pipes 122 40 mm nominal outer dia pipes 123 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 124 15 mm nominal outer dia pipes 125 20 mm nominal outer dia pipes 126 25 mm nominal outer dia Pipes 127 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 128 25mm dia, nominal bore 129 32 mm dia, nominal bore 130 40 mm dia, nominal bore 131 50 mm dia, nominal bore 132 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 133 25 to 40 mm nominal bore 134 50 to 80 mm nominal bore 135 Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore: 136 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) 137 20 mm nominal outer dia pipes 138 25 mm nominal outer dia pipes 139 32 mm nominal outer dia pipes 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 141 20 mm nominal bore 142 25 mm nominal bore 143 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115mm nominal bore 144 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore 145 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 146 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 147 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 148 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 149 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 150 S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work.150mm dia SWR Pipe 151 Haunching of SWR Pipes with cement concrete in 1:2:4 (1 cement: 2 coarse sand : 4 Stone grit 20mm nominal size) with a complete section of size 300x300mm around the pipe. Including supply of all materials and Labour complete. 152 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 153 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75i) For Sewer Line 154 (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. 155 Extra for depth of man hole size 90x80 cm 156 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia 157 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design180 x 150 mm. size P type 158 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 159 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 160 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 161 50mm nominal bore. 162 40mm nominal bore. 163 32mm nominal bore. 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 165 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 166 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 168 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 169 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 170 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 171 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 172 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 173 Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 174 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 175 5/6 A switch 176 3 pin 5/6 A socket outlet 177 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 178 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 179 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 180 Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 181 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 182 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 183 Installation of Upto 450 mm sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 184 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 185 Supplying and drawing 2 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 186 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 187 Supplying and drawing of 1 run of cable UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 188 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 189 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 190 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 191 4 way (4 + 12), Double door 192 6 way (4 + 18), Double door 193 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG 194 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 195 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 196 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 197 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 198 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 199 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 200 40 A 201 63 A 202 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 203 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 204 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 205 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 206 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 207 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel : Incoming - 200 Amp MCCB - 1 No. Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No. (Complete as per requirment directed by E/I) 208 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 209 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 15 to 18 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 210 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 211 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 212 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 213 size 6 sq mm x 2 core 214 size 70 sq mm x 3-1/2core 215 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 216 2 X 6 sq. mm (19mm) 217 3½ X 70 sq. mm (32mm) 218 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 219 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 220 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 221 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 222 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 223 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 224 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 225 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 226 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 227 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 228 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 229 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 230 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 231 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 232 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 233 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 234 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 235 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 236 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 450 lpm at 35 m Head ipes & Accessories : 237 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 238 80 mm dia 239 100 mm dia 240 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 241 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 242 80 mm dia 243 100 mm dia 244 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 245 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 246 80 mm dia 247 100 mm dia 248 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 249 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 250 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 251 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 252 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 253 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 254 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 255 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 25 sq mm x 3-1/2core 256 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 257 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 258 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Fire Sand Bucket : 259 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 260 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 261 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 262 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 263 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 264 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 265 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 266 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 267 Control Panels (for Terrace Pump) :Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 268 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 269 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 270 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 271 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. 272 Providing and fixing in position pre-moulded joint filler in expansion joints. 273 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. 274 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 275 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 276 Supplying, installation, testing and commissioning ofL.T. panel fully compartmentalized cubical type sheet clad floor mounted totally enclosed , extensible on both sides, switch board suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, as required as per specification and schematic diagram as required. (Street lighting Panel) INCOMER:-1 Nos.63 Amps. TPN MCCB(25 KA) 1 Nos.63 Amps. Automatic changeover switch 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASS BUS BARS:- 100 Amps. TP&N Aluminium bus bars (25 KA) OUT GOINGS:- 6 Nos.32A TPN, MCB (10KA). 4 Nos. 24 Hr Timer Switch 4 Nos. 32A TPN contactor 277 Supplying, installation & testing of 6.0 m high Octagonal pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 130mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 4Cx16 sq.mm YWY cables and 3x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost ofRCC foundation for pole as per structural detail. 278 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 Protection complete in all respect 279 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 Sq mm x 4 Core 280 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 16 Sq mm x 4 Core 281 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.16 Sq mm MR 282 S.I.T.C. of IP Based EPABX System comprising of core switches and L switch with 10g, 10 Giga SFP modules, industry standard appliance server, cloud based, interprise -grade UC solution, MID/ENTRY Level IP/SIP Phone with dual 1 gig ports, racks,CAT6A cable, patch panels, OFC etc. 283 S.I.T.C. of LAN System comprising of core switches and L switch with 10g, 10 Giga SFP modules WIFIAccess points WIFI controller network management software racks, CAT 6A Cable patch panels OFC etc. , 284 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 285 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 286 Providing & fixing 75mm dia vent pipes. 287 Providing & fixing of 75mm dia cast iron terminal guard. 288 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 560mm internal diameter 289 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 400 mm dia 291 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 292 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, i200 mm nominal size diancluding hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 293 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 294 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 295 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 296 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 297 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 298 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 299 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 300 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 10.1 301 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 302 ANGLE IRON90*90*6 mm 303 T-SECTION 90*90*6 304 HOLD FAST40*6 FLAT 305 G.I. Pipe(80 MM DIA) (DSR-18.12.8)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
33.
Housing Urban and Rular Development #9443251 Technical Bid
Tender For Development Of Tourism Office At Distt. Deoria, 1 TOURIST FACILITATION CENTER (Civil) 2 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. Excavation by Manual means [Special tools] 3 From Lvl. 0.00 To 1.50 Mtr 4 Filling of carted earth. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8Km from the site of work and including watering, dressing etc. Rate to include cost of all materials, labour, T&P etc. required for proper completion the work. 6 Concrete with 4cm. Gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour, tools and plants etc. required for proper completion the work. 7 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete 8 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 9 (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. 10 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto plinth Lvl.(M-25) 11 R.C.C. work in Footing 12 R.C.C. work in Column 13 R.C.C. work in Beam 14 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto Above Lvl.(M-25) 15 R.C.C. work in Lintel 16 R.C.C. work in Slab 17 R.C.C. work in Beam 18 R.C.C. work in Column 19 M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, T & P etc reqiored for proper completion of the work. 20 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 21 Providing machine made Wire Cut Bricks in Arches where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 22 Extra for forming cavity 42 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 460 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 23 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) 24 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 25 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 26 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 27 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 28 Upto Plinth Lvl. 29 Above Plinth Lvl. 30 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 31 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 32 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 33 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 34 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 35 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm 36 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 37 Providing and fixing three-layer construction, wooden plank/engineered Wood size185—200 mmX 2000-2426 mmof 3 strip oak with a total thickness of 15 mm and a wear layer thickness of 3.5mm should be resandable up to 2 to 3 times. Surface Treatment: Matt/ Ultra matt Lacquer, Core: Pine/ Spruce/ Alder. Joint: Woodloc 5S, fifth-generation locking system, Moisture Content as per EN 13183: 7%, Reaction to fire as per EN13501-2:1 Dfl- s1CARB 2 compliant, Biological Durability as per EN350-2 Class1 confirming to strict quality and environment norms. It should be certified by PEFC, FSC, Blue Angel, and Real Wood.Matching Accessories like skirting & profile with,. Installation should be done by a trained and authorized team on Zero level of the hard surface .Make-Kahrs, Armstrong 38 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 39 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 40 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 41 Granite of any colour and shade (Area of slab upto 0.50 sqm) 42 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 43 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. 44 (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 45 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 46 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 50 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 52 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) 53 Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 54 Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 55 Float glass panes 56 5.0 mm thick glass panes (weight not lessthan 12.50 kg/sqm). 57 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 58 Providing and fixing to existing door frames. 59 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturatedpolyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 60 Supply and fix powder coated Aluminium louvered door double leaves type overall size as per drawing for maintenance opening in the service area ,with all required fixing angles, bolts, welding including1’ wide Aluminium Louvers of approved shade in door Including allaccessories required for installation of the louvers, painting and priming and all required as per drawings and Engineer instructions in charge 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 63 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 64 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 65 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 66 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 67 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. 68 (a) 300mm x 16mm 69 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 70 (a) 250 mm x 10mm 71 (b) 200 mm x 10mm 72 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 73 125 mm 74 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 75 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 76 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 77 Construction of drain along with apron. 78 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 79 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: 80 a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: 81 b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. 82 c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. 83 d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 84 Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 85 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. 86 The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm 87 (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 88 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 89 Providing & fixing mineral fibre false ceiling tiles at all height of size 595 x 595 mm. of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85% Thermal Conductivity k = 0.052- 0.057 w/m K, Fire performance as per (Bs 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all around galvanized iron secion of 0.33mm thick (galvanized @ 120 gsm) 90 comprising of main T-Runners of 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item (galvanised @ 80 gsm) 50mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to 91 centre along main T. The system should rest on periphery walls/ partitions with the help of G.I. perimeter wall angle of size 24x24x3000mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyster baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 92 With 16 mm thick beveled tegular mineral fibre false ceiling tile 93 Centering and shuttering including strutting, propping etc. and removal of form for 94 Foundations, footings, bases of columns, etc. for massconcrete 95 Suspended floors, roofs, landings, balconies and accessplatform 96 Lintels, beams, plinth beams, girders, bressumers andcantilevers 97 Columns, Pillars, Piers, Abutments, Posts and Struts 98 Providing, Suppling & fixing of cultural Terracotta tile mural work of 20mm thick inspired from the extraction of Ramayana and the Local Tangible context as per architect incharge. 99 FIRE FIGHTING WORKS 100 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 101 150 mm dia. 102 100 mm dia. 103 80 mm dia. 104 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 105 150 mm dia. 106 100 mm dia. 107 80 mm dia. 108 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 109 150 mm dia. 110 100 mm dia. 111 80 mm dia. 112 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 113 2 way - 100 mm dia M.S. Pipe (Siamese Connection) 114 4 way - 150 mm dia M.S. Pipe 115 TOTAL OF SUBHEAD-I 116 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump) 117 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 118 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 119 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 120 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 121 900 lpm at 35 m Head 122 450 lpm at 35 m Head 123 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 124 Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) 125 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 126 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 127 150 mm dia. 128 100 mm dia. 129 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 130 150 mm dia. 131 100 mm dia. 132 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 133 80 mm nominal bore 134 100 mm nominal bore 135 150 mm nominal bore 136 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 137 Single headed Gunmetal 138 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 139 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 140 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 141 40 m 142 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 143 Gun metal 144 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 145 Gun metal 146 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 147 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 148 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 149 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 150 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 151 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 152 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 153 TOTAL OF SUBHEAD-III 154 FIRE FIGHTING PANEL 155 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 9.3 KW/12.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. Star delta starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 156 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 157 Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 158 3 Core, X 10 sqmm. 159 3 Core, X 6 sqmm. 160 Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 161 3 Core, X 10 sqmm. 162 3 Core, X 6 sqmm. 163 Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathedarmoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 164 4 x 2.5 sq.mm 165 2 x 2.5 sq.mm 166 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 167 150 mm width x 50mm depth x 1.6 mm thickness. 168 FIRE ALARM SERVICES 169 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 170 6 zone panel for fire alarm system 171 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. 172 Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. 173 Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. 174 Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. 175 Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. 176 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 177 4-Zone Panel. 178 6-Zone Panel. 179 10-Zone Panel. 180 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 182 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. 184 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. 185 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 186 INTERNAL W/S & SANITATION WORK 187 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 188 W.C. pan with ISI marked white solid plastic seat and lid 189 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. 190 Providing & fixing toilet paper holder 191 C.P. brass 192 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 193 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 194 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 195 White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 196 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 197 (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 198 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 199 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 200 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 201 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 202 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 203 15 mm nominal bore 204 Providing and fixing uplasticised PVC connection pipe with brass unions : 205 45 cm length 206 15 mm nominal bore 207 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 208 100 mm diameter 209 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 210 15 mm nominal bore 211 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 212 15 mm nominal dia 213 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 214 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 215 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 216 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 217 Kitchen sink with drain board 218 510x1040 mm bowl depth 200 mm 219 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete 220 Flexible Pipe 221 32mm Dia 222 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 223 15mm nominal bore 224 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 225 15mm nominal bore 226 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 227 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 228 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. 229 Granite Stone of approved shade 230 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 231 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 232 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. 233 Capacity 25 Liters 234 TOTAL OF SUBHEAD-I 235 SUB HEAD-II-WATER SUPPLY 236 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 237 Concealed work, including cutting chases and making good the walls etc. 238 For Internal Toilet 239 15 mm nominal outer dia Pipes 240 20 mm nominal outer dia Pipes 241 25 mm nominal outer dia Pipes 242 32 mm nominal outer dia Pipes 243 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 244 Internal work - Exposed on wall 245 20 mm nominal bore 246 25 mm nominal bore 247 32 mm nominal bore 248 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 249 Terrace loop & Tank Filling Pipe 250 40 mm nominal bore 251 50 mm nominal bore 252 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 253 40mm diameter pipe 254 50mm diameter pipe 255 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 256 40mm diameter pipe 257 50mm diameter pipe 258 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 259 For vertical pipe connection with terrace ringmain 260 20 mm nominal bore 261 25mm nominal bore 262 32mm nominal bore 263 40mm nominal bore 264 50mm nominal bore 265 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 266 25 to 40 mm nominal bore 267 50 to 80 mm nominal bore 268 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 269 40 mm nominal bore, 206 mm long, weighing not less than 690 gms 270 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 271 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 272 15mm dia (9 mm thickness) 273 20mm dia (9 mm thickness) 274 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 275 Lehry Make Automatic OHT Level Control System Consist of Following Items 276 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 277 40mm 278 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 279 25mm dia. 280 32mm dia. 281 40mm dia. 282 50mm dia. 283 65mm dia. 284 80mm dia. 285 100mm dia. 286 150mm dia. 287 200mm dia. 288 250mm dia. 289 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 290 110 mm dia (for rain water) 291 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 292 Single Push Fit Coupler 293 110 mm dia 294 Single tee with door 295 110x110x110 mm 296 Plain bend 87.5 deg 297 110 mm dia 298 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 299 110 mm dia 300 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 301 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 302 All kind of soil 303 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 304 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 305 100mm dia SWpipe 306 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 307 Internal Toilet (Soil & Waste Pipe) 308 75 mm 309 110 mm 310 Exposed on Wall (Soil & Waste Pipe) 311 110 mm 312 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 313 Bend without door (45°) 314 75mm 315 110mm 316 Bend without door (87.5°) 317 75mm bend 318 110mm 319 Y Fitting without door 320 75mm 321 110mm 322 Single Tee without door 323 75mm 324 110 mm 325 Single Tee with door 326 75mm 327 110 mm 328 Bend with door (87.5°) 329 75mm 330 110 mm 331 Clean Out Plug (COP) 332 75mm 333 110 mm 334 Reduced Y Fitting without door 335 110mm x 75mm 336 Reduced Tee with door 337 110mm x 75mm 338 Coupler 339 75mm 340 110mm 341 Vent Cowl 342 110mm 343 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 344 For Wash basin & Urinal 345 32mm dia. Pipe 346 50mm dia. pipe 347 Elbow (45°) 348 32mm 349 50mm 350 Elbow (90°) 351 32mm 352 50mm 353 T fitting 354 32mm 355 50mm 356 Coupler 357 32mm 358 50mm 359 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 360 110mm x 75mm x 50mm/40mm (Toilet) 361 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 362 110mm x 75mm (Toilet & Kitchen) 363 Providing and fixing PTMT grating of approved quality and colour. 364 Rectangular type with openable circular lid 365 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 366 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 367 150 x 100mm size P-type 368 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 369 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 370 100 mm diameter 371 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 372 All kind of soil 373 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 374 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 375 100mm dia SWpipe 376 INTERNAL ELECTRIFICATION WORKS 377 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 378 Group - B 379 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 380 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required 381 Group -A 382 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 383 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 384 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 385 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 386 2 X 6 sq. mm + 1 X 4 sq. mm earth wire 387 2 x 10 sq.mm + 1 x 6sq.mm. earth wire 388 2 x 16 sq.mm + 1 x 6sq.mm. earth wire 389 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire 390 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 391 4 x 16 sq.mm + 2 x 6sq.mm. earth wire 392 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 393 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 394 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 395 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 396 Wiring for light/ power plug plug with 2 X 4 sq. mm FRLC PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FRLC PVC insulated copper conductor single core cable for loop earthing as required 397 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 398 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 399 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 400 5/6 A switch 401 3 pin 5/6 A socket outlet 402 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 403 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 404 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. 405 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 406 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 407 Upto 450 mm sweep 408 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 409 Supply of surface/Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 410 Supply of surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 411 Supply of LED 4ft 2x20W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor Make Jaguar LUNI01X220XW, Philips / BAJAJ or Eq. 412 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 413 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 414 Supply ofSurface mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect 415 Supply of Surface mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 416 Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. 417 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 418 Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, 419 Supplying and fixing brass batten/ angle holder including connection etc. as required. 420 Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. 421 Supplying of 9 Watt Decorative LED Wall Light complete in all respect. 422 MACTY SURFACE DOWNLIGHT Divinity Sarface Macty Up and Down Light Outdoor Fixture (IP-65) Optical system=LensWattage=2x10WLumen=1600lmCCT=3000KCRI>80Beam Angle=12° /24° / 36° / 60°Driver=Non Dimmable Material=Aluminium Dia castingStandard Lifetime=L70Minimum 50000 HoursFinish=BlackDimension=Dia=100mm,H=100mm 423 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver andapable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 424 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 425 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 426 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 427 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 428 300mm EXHAUST FAN 429 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 430 63 A,25KA,FP MCCB 431 100 A,30KA,FPMCCB 432 125 A,36KA,FPMCCB 433 160 A,25KA,FP MCCB 434 200 A, 36KA,FPMCCB 435 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 436 6 Way Double Door 437 8 way, Double door 438 12 way, Double Door 439 16 way, Double Door 440 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 441 4 Way Double door 442 6 way Double door 443 8 way Double door 444 12 way Double door 445 Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 446 4 way (4 + 12), Double door 447 8 way (4 + 24), Double door 448 Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. 449 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 450 40 amps SP MCB 451 40 amps DP MCB 452 63 amps DP MCB 453 40 amps TP MCB 454 63 amps TP MCB 455 40 amps 4P MCB 456 63 amps 4P MCB 457 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 458 40 amps 459 63 amps 460 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 461 40 amps 462 63 amps 463 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 464 25 amps 465 40 amps 466 63 amps 467 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 468 Single pole 469 Double pole 470 Triple pole 471 Triple pole and neutral 472 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 473 Supplying and fixing 1P LCD Energy Meter 5-30A with BOX 474 Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter 475 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 476 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 477 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 478 90 mm dia (OD-90 mm & ID-76 mm nominal) 479 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. 480 The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 481 The minimum clearances between bus bars shall be as follows : 482 Phase to phase - minimum 20mm 483 Phase to neutral-minimum 15mm 484 MAIN PANEL 485 Same as above item but following mountings. 486 INCOMER:- 487 One (1) No 160 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity with thermal Magnetic release 488 Metering : 489 1 Set of CTs one of 160/ 5Amp ratio for Multifunction Meter 490 One (1) Set of Phase Indication Lamp. 491 Bus Bar : 492 One (1) No.200 Amp.TPN aluminimum bus bar of suitable length. 493 Outgoing : 494 Phase indication lamps on each outgoing to be provided. 495 40 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 6 No 496 63 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 2 No 497 10 Amps DP MCB of 10KA (Ics=Icu)Breaking Capacity- 2 No 498 2 Nos.Space & Spare 499 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 500 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 501 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 502 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 503 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 504 Providing and Fixing 6 SWG dia G.I. Wire on surface or in recess for connection etc. as required. 505 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 506 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 507 Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 508 2 Pair (4 core) 509 Providing, laying, connecting and testing of multi-core telephone unarmoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. 510 100 Pair telephone cable 511 20 Pair telephone cable 512 10 Pair telephone cable 513 5 Pair telephone cable 514 Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 515 5 Pair tag block 516 10 pair tag block 517 20 pair tag block 518 100 pair tag block 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20mm dia PVC conduit 521 25mm dia PVC conduit 522 32mm dia PVC conduit 523 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 524 1 or 2 Module (75mmX75mm) 525 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 526 Telephone socket outlet 527 TV antenna socket outlet 528 Bell Push 529 RJ-45 Data Socket outlet 530 Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. 531 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 532 1 run of cable 533 Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. 534 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 535 Up to 35 sq.mm. 536 Above 35 sq.mm. and up to 95 sq.mm. 537 Above 95 sq.mm. and upto 185 sq.mm. 538 Above 185 sq.mm. and up to 400 sq.mm. 539 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required 540 Up to 35 sq.mm. 541 Above 35 sq.mm. and up to 95 sq.mm. 542 Above 95 sq.mm. and upto 185 sq.mm. 543 Above 185 sq.mm. and up to 400 sq.mm. 544 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 545 Up to 35 sq.mm. 546 Above 35 sq.mm. and up to 95 sq.mm. 547 Above 95 sq.mm. and upto 185 sq.mm. 548 Above 185 sq.mm. and up to 400 sq.mm. 549 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 550 Up to 35 sq.mm. 551 Above 35 sq.mm. and up to 95 sq.mm. 552 Above 95 sq.mm. and upto 185 sq.mm. 553 Above 185 sq.mm. and up to 400 sq.mm. 554 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 555 Up to 35 sq.mm. 556 Above 35 sq.mm. and up to 95 sq.mm. 557 Above 95 sq.mm. and upto 185 sq.mm. 558 Above 185 sq.mm. and up to 400 sq.mm. 559 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 560 Up to 35 sq.mm. 561 Above 35 sq.mm. and up to 95 sq.mm. 562 Above 95 sq.mm. and upto 185 sq.mm. 563 Above 185 sq.mm. and up to 400 sq.mm. 564 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required 565 Upto 35 sq. mm (clamped with 1mm thick saddle 566 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp 567 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp 568 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 569 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 570 Upto 35 sq. mm (clamped with 1mm thick saddle) 571 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 572 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 573 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 574 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 575 3.5 x 400 sq.mm. 576 3.5 x 300 sq.mm. 577 3.5 x 240 sq.mm. 578 3.5 x 185 sq.mm 579 3.5 x 150 sq.mm 580 3.5 x 120 sq.mm 581 3.5 x 95 sq.mm 582 3.5 x 70 sq.mm 583 3.5 x 50 sq.mm 584 3.5 x 35 sq.mm 585 3.5 x 25 sq.mm. 586 4 x 25 sq.mm 587 4 x 16 sq.mm 588 4 x 10 sq.mm 589 4 x 6 sq.mm 590 2 x 16 sq.mm, 591 2 x 10 sq.mm, 592 2 x 6 sq.mm, 593 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 594 2 X 6 sq. mm (19mm) 595 2 X 10 sq. mm (19mm) 596 2 X 16 sq. mm (22mm) 597 3½ X 25 sq. mm (28mm) 598 3½ X 35 sq. mm (32mm) 599 3½ X 50 sq. mm (35mm) 600 3½ X 70 sq. mm (38mm) 601 3½ X 95 sq. mm (45mm) 602 3½ X 120 sq. mm (45mm) 603 3½ X 150 sq. mm (50mm) 604 3½ X 185 sq. mm (57mm) 605 3½ X 225 sq. mm (62mm) 606 3½ X 240 sq. mm (62mm) 607 3½ X 300 sq. mm (70mm) 608 3½ X 400 sq. mm (82mm) 609 4 X 10 sq. mm (25mm) 610 4 X 16 sq. mm (28mm) 611 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 612 100 mm dia 613 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 614 100mm dia 615 150 mm dia 616 250 mm dia 617 300 mm dia 618 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 619 90 mm dia (OD-90 mm & ID-76 mm nominal) 620 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 621 100 mm wide x 50 mm depth x 1.6 mm thickness. 622 150 mm wide x 50 mm depth x 1.6 mm thickness. 623 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 624 100 mm wide x 50 mm depth x 1.6 mm thickness. 625 150 mm wide x 50 mm depth x 1.6 mm thickness. 626 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Tee (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceilingwith G.I. suspenders including G.I. bolts & nuts, etc. as required. 627 100 mm wide x 50 mm depth x 1.6 mm thickness. 628 EXTERNAL SEWERAGE & WATER SUPPLY SYSTEM 629 COST OF SEWERAGE WORKS 630 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 631 up to 1.50 m depth 632 Pipes 80 mm to 300 mmdiameter 633 1.50 m to 3.00 m depth 634 Pipes 80 mm to 300 mmdiameter 635 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) 636 Depth not exceeding 1.5 meter 637 Depth 1.5 to3.00meter 638 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 639 150 mm.dia. RCCPipes 640 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 641 150 mm.dia. RCCPipes 642 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 643 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 644 With common burnt clay FPS (non modular) bricks of class designation 75 645 (i) For Sewer Line 646 Extra for depth for manholes: 647 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 648 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). 649 With common burnt clay FPS (non modular) bricks of class designation 75 650 (i) For Sewer Line 651 Extra for depth for manholes: 652 Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 653 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 654 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 655 80mm nominal bore. 656 65mm nominal bore. 657 50mm nominal bore. 658 40mm nominal bore. 659 32mm nominal bore. 660 25mm nominal bore. 661 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 662 80mm nominal bore. 663 65mm nominal bore. 664 50mm nominal bore. 665 40mm nominal bore. 666 32mm nominal bore. 667 25mm nominal bore. 668 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) 669 80mm nominal bore. 670 65mm nominal bore. 671 50mm nominal bore. 672 40mm nominal bore. 673 32mm nominal bore. 674 25mm nominal bore. 675 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 676 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 677 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : 678 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 679 EXTERNAL SEWERAGE SYSTEM (SEPTIC TANK) 680 SEPTIC TANK & SOAK PIT 681 Size :- Length = 5.0 M. Width = 2.0M Total Depth =3.00M 682 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 683 In all kind of soil upto 1.5m depth 684 In all kind of soil upto 1.5m to 3.0m. depth 685 In all kind of soil upto 3.0m to 4.5m. depth 686 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 687 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 688 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 689 Suspended floors, roofs, landings, balconies and access platform. 690 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 691 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 692 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 693 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 694 Providing & fixing 75mm dia vent pipes. 695 Providing & fixing of 75mm dia cast iron terminal guard. 696 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 697 M.D. -10- Circular shape 500mm internal diameter 698 M.D. -2.5- Circular shape 450mm internal diameter 699 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 700 With F.P.S. bricks 701 RAIN WATER HARVESTING WORKS 702 RECHARGE PITS 703 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 704 In all kind of soil upto 1.5m depth 705 In all kind of soil upto 1.5m to 3.0m. depth 706 In all kind of soil upto 3.0m to 4.5m. depth 707 In all kind of soil upto 4.5 m to 6.0m. depth 708 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 709 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 710 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 711 Suspended floors, roofs, landings, balconies and access platform. 712 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 713 12mm cement plaster on rough side of single or half brick wall mix 714 1:3 (1 cement : 3 Coarse sand) 715 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 716 With 20x20mm square bar 717 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 718 M.D. -10- Circular shape 500mm internal diameter 719 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 720 Drilling of 300mm dia bore hole manually. 721 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 722 150 mm nominal size dia 723 Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 724 Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 725 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 726 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 727 DESILTING CHAMBER 728 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 729 In all kind of soil upto 1.5m depth 730 In all kind of soil upto 1.5m to 3.0m. depth 731 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 732 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 733 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 734 Suspended floors, roofs, landings, balconies and access platform. 735 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 736 15mm cement plaster on rough side of single or half brick wall mix 737 1:3 (1 cement : 3 Coarse sand) 738 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 739 With 20x20mm square bar 740 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 741 M.D. -10- Circular shape 500mm internal diameter 742 COST OF EACH RAIN WATER HARVESTING 743 TOTAL NO. OF RAIN WATER HARVESTING 744 TOTAL COST OF RAIN WATER HARVESTING 745 DRAINAGE NETWORK 746 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 747 up to 1.50 m depth 748 Pipes 80 mm to 300 mmdiameter 749 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 750 150 mm.dia. RCCPipes 751 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 752 150 mm. dia. 753 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 754 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 755 Drain 300 wide average.Depth 45 cm with R.C.C. slab 756 INTERLOCKING PATHWAY (283 Sqm) 757 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (D.S.R. 2.8.1) 758 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 759 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 760 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 761 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 762 TRIMIXING FOR PARKING AREA 184.98 SQM 763 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 764 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 765 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finishedwith screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specificationsand directions of Engineer-in-charge. Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately (DSR-16.75) 766 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade A sealing compound. DSR- 16.46.1 767 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.[ DSR 5.22.6 ] 768 BORING & SUBMERSIBLE PUMP 769 Drilling of 200 mm dia bore hole. 770 Supply of 125 mm dia MSpipe as per IS1239 771 Supply of 125 mm dia slotted MSpipe 772 Supply and fixing of nylon jali around the slotted pipes complete as required. 773 Providing and packing of coarse sand / pea gravel around the pipe. 774 Transport of boring tools other required equipements and installation at site. 775 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 776 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 777 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 778 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 779 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 780 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 781 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 782 Testing and development of tube well. 783 HORTICULTURE 784 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 785 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 786 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 787 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 788 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 789 Rough dressing the trenched ground including breaking the clods. 790 Fine dressing the ground 791 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 792 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 793 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 794 With grass Turf 795 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 796 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 797 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 798 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 799 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 800 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 801 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 802 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 803 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 804 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 805 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 806 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 807 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 808 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 809 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 810 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 811 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 812 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 813 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 814 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 815 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
34.
Educational and Research Institute #9437302 AOC
Tender For Civil maintenance Work Rate Contract- 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.(D.S.R.2023,Vol.1,Code-2.8)2.8.1 2 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 2.9.1 Ordinary rock. (D.S.R.2023,Vol.1,Code-2.9)2.9.1 3 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. Complete. (D.S.R.2023,Vol.1,Code-2.25 A) 4 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (D.S.R.2023,Vol.1,Code-2.31) 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources (D.S.R.2023,Vol.1,Code-4.1)4.1.8 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (D.S.R.2023,Vol.1,Code-4.1)4.1.3 7 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 4.5.1 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (D.S.R.2023,Vol.1,Code-4.5)4.5.1 8 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) (D.S.R.2023,Vol.1,Code-5.1)5.1.2 9 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(D.S.R.2023,Vol.1,Code-5.3) 10 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.5.18.3 25 mm thick (D.S.R.2023,Vol.1,Code-5.18)5.18.3 11 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). (D.S.R.2023,Vol.1,Code-5.23) 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) (D.S.R.2023,Vol.1,Code-6.1)6.1.1 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (D.S.R.2023,Vol.1,Code-6.4)6.4.1 14 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (D.S.R.2023,Vol.1,Code-6.13)6.13.2 15 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)(D.S.R.2023,Vol.1,Code-7.1)7.1.1 16 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand) (D.S.R.2023,Vol.1,Code-7.2)7.2.1 17 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red8.2.2.2 Area of slab over 0.50 sqm(D.S.R.2023,Vol.1,Code-8.2)8.2.2/8.2.2.2 18 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.8.10.2 Granite Stone of approved shade (D.S.R.2023,Vol.1,Code-8.10)8.10.2 19 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete :8.30.1 18 mm thick (D.S.R.2023,Vol.1,Code-8.30)8.30.1 20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (D.S.R.2023,Vol.1,Code-9.21)9.21.1 21 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding (D.S.R.2023,Vol.1,Code-9.48)9.48.1 22 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 9.51.1 With 2nd class teak wood beading 62X19 mm sqm (D.S.R.2023,Vol.1,Code-9.51)9.51.1 23 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.95.1 125x75x4 mm (D.S.R.2023,Vol.1,Code-9.95)9.95.1 24 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 9.75.1 300x16x5 mm (D.S.R.2023,Vol.1,Code-9.75)9.75.1 25 Providing and fixing bright finished brass handles with screws etc. complete: 9.81.1 125 mm (D.S.R.2023,Vol.1,Code-9.81)9.81.1 26 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(D.S.R.2023,Vol.1,Code-9.83) 27 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC C channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturers specification & drawing.9.120.2 30 mm thick pre laminated PVC door shutters. (D.S.R.2023,Vol.1,Code-9.120) 9.120.2 28 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) (D.S.R.2023,Vol.1,Code-9.168) 29 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.10.5.1 Using M.S. angels 40x40x6 mm for diagonal brac(D.S.R.2023,Vol.1,Code-10.5) 10.5.1 30 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover(D.S.R.2023,Vol.1,Code-10.6) 10.6.1 31 Providing and fixing ball bearing for rolling shutters. (D.S.R.2023,Vol.1,Code-10.7) 32 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (D.S.R.2023,Vol.1,Code-10.15) 10.15.1 33 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (D.S.R.2023,Vol.1,Code-10.31) 34 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube (D.S.R.2023,Vol.1,Code-10.26)10.26.1 35 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (D.S.R.2023,Vol.1,Code-10.28) 36 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. 10.29.1 Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both side (D.S.R.2023,Vol.1,Code-10.29)10.29.1 37 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 10.30.1 4.0 mm thick glass panes (D.S.R.2023,Vol.1,Code-10.30)10.30.1 38 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 10.30.2 5.5 mm thick glass panes(D.S.R.2023,Vol.1,Code-10.30)10.30.2 39 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate(D.S.R.2023,Vol.1,Code-11.3)11.3.1 40 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.(D.S.R.2023,Vol.1,Code-11.4) 41 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 11.13.1 40 mm wide and 4 mm thick (D.S.R.2023,Vol.1,Code-11.13)11.13.1 42 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. 11.21.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1.1 Acid and alkali resistant tilek(D.S.R.2023,Vol.1,Code-11.21)11.21.1/11.21.1.1 43 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.11.21.2 In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2.1 Acid and alkali resistant tile(D.S.R.2023,Vol.1,Code-11.21)11.21.2/11.21.2.1 44 Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. 11.22.1 Marble tiles (polished) Raj Nagar 11.22.1.1 8 mm thick (D.S.R.2023,Vol.1,Code-11.22)11.22.1/11.22.1.1 45 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :11.23.1 Makrana white second quality(D.S.R.2023,Vol.1,Code-11.23)11.23.1 46 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick(D.S.R.2023,Vol.1,Code-11.26)11.26.1 47 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.(D.S.R.2023,Vol.1,Code-11.27) 48 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.(D.S.R.2023,Vol.1,Code-11.34) 49 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.11.41.2 Size of Tile 600x600 mm(D.S.R.2023,Vol.1,Code-11.41)11.41.2 50 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.2 Size of Tile 600x600 mm (D.S.R.2023,Vol.1,Code-11.46)11.46.2 51 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.0 mm thick with zinc coating not less than 275 gm/m²(D.S.R.2023,Vol.1,Code-12.1)12.1.1 52 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 12.15.1 With residual type petroleum bitumen of grade VG -10(D.S.R.2023,Vol.1,Code-12.15)12.15.1 53 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 12.31.1 Flat surfaces (D.S.R.2023,Vol.1,Code-12.31)12.31.1 54 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board(D.S.R.2023,Vol.1,Code-12.45)12.45.3 55 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.(D.S.R.2023,Vol.1,Code-12.52)12.52.3 56 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) (D.S.R.2023,Vol.2,Code-13.2)13.2.1 57 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement: 4 fine sand) (D.S.R.2023,Vol.2,Code-13.3)13.3.1 58 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.1 1:3 (1 cement: 3 fine sand)(D.S.R.2023,Vol.2,Code-13.8)13.8.1 59 White washing with lime to give an even shade : 13.37.1 New work (three or more coats) (D.S.R.2023,Vol.2,Code-13.37)13.37.1 60 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer (D.S.R.2023,Vol.2,Code-13.41)13.41.1 61 Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)(D.S.R.2023,Vol.2,Code-13.44)13.44.1 62 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (D.S.R.2023,Vol.2,Code-13.45)13.45.1 63 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm (D.S.R.2023,Vol.2,Code-13.46)13.46.1 64 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(D.S.R.2023,Vol.2,Code-13.47)13.47.1 65 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (D.S.R.2023,Vol.2,Code-13.48)13.48.1 66 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specification : 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.2023,Vol.2,Code-13.48)13.48.2 67 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture (D.S.R.2023,Vol.2,Code-13.48)13.48.3 68 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm (D.S.R.2023,Vol.2,Code-13.48A)13.48A.1 69 Applying priming coat:13.50.2 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood (D.S.R.2023,Vol.2,Code-13.50)13.50.2 70 Applying priming coat:13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (D.S.R.2023,Vol.2,Code-13.50)13.50.3 71 Applying priming coat:13.50.4 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) (D.S.R.2023,Vol.2,Code-13.50)13.50.4 72 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : 13.51.1 One coat (D.S.R.2023,Vol.2,Code-13.51)13.51.1 73 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : 13.51.2 Two coat (D.S.R.2023,Vol.2,Code-13.51)13.51.2 74 Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new work: 13.55.1 100 mm diameter pipes (D.S.R.2023,Vol.2,Code-13.55)13.55.1 75 Painting with oil type wood preservative of approved brand and manufacture : 13.57.1 New work (two or more coats) (D.S.R.2023,Vol.2,Code-13.57)13.57.1 76 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactur (D.S.R.2023,Vol.2,Code-13.62)13.62.1 77 Polishing on wood work with ready mixed wax polish of approved brand and manufacture : 13.69.1 New work (D.S.R.2023,Vol.2,Code-13.69)13.69.1 78 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (D.S.R.2023,Vol.2,Code-13.80) 79 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.81.1 Old work(one or more coat)(D.S.R.2023,Vol.2,Code-13.81)13.81.1 80 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.82.1 One coat (D.S.R.2023,Vol.2,Code-13.82)13.82.1 81 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.82.2 Two coat (D.S.R.2023,Vol.2,Code-13.82)13.82.2 82 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.83.1 One coat (D.S.R.2023,Vol.2,Code-13.83)13.83.1 83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.83.2 Two coat (D.S.R.2023,Vol.2,Code-13.83)13.83.2 84 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (D.S.R.2023,Vol.2,Code-13.85)13.85.1 85 White washing with lime to give an even shade : 13.87.1 Old work (two or more coats) (D.S.R.2023,Vol.2,Code-13.87)13.87.1 86 White washing with lime to give an even shade : 13.87.2 Old work (one or more coats) (D.S.R.2023,Vol.2,Code-13.87)13.87.2 87 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Comple (D.S.R.2023,Vol.2,Code-13.88) 88 Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : 13.90.1 Old work (one or more coats) (D.S.R.2023,Vol.2,Code-13.90)13.90.1 89 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (D.S.R.2023,Vol.2,Code-13.91) 90 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.92.1 Old work (one or more coats) (D.S.R.2023,Vol.2,Code-13.92)13.92.1 91 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.99.1 One or more coats on old work(D.S.R.2023,Vol.2,Code-13.99)13.99.1 92 Painting with aluminium paint of approved brand and manufacture to give an even shade: 13.100.1 One or more coats on old work(D.S.R.2023,Vol.2,Code-13.100)13.100.1 93 Polishing on wood work with ready made wax polish of approved brand and manufacture : 13.104.1 Old work (D.S.R.2023,Vol.2,Code-13.104)13.104.1 94 Finishing walls with textured exterior paint of required shade : 13.110.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. (D.S.R.2023,Vol.2,Code-13.110)13.110.1 95 Finishing walls with textured exterior paint of required shade : 13.110.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm.(D.S.R.2023,Vol.2,Code-13.110)13.110.2 96 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.111.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (D.S.R.2023,Vol.2,Code-13.111)13.111.1 97 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.111.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm)(D.S.R.2023,Vol.2,Code-13.111)13.111.2 98 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 13.112.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (D.S.R.2023,Vol.2,Code-13.112)13.112.1 99 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 13.112.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm) (D.S.R.2023,Vol.2,Code-13.112)13.112.2 100 Melamine polishing on wood work (one or more coat). (D.S.R.2023,Vol.2,Code-13.114) 101 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. (D.S.R.2023,Vol.2,Code-13.115) 102 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand)(D.S.R.2023,Vol.2,Code-14.1)14.1.1 103 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.2.1 Door chowkhats (D.S.R.2023,Vol.2,Code-14.2)14.2.1 104 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.2.2 Window chowkhats (D.S.R.2023,Vol.2,Code-14.2)14.2.2 105 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.2.3 Clerestory window chowkhats (D.S.R.2023,Vol.2,Code-14.2)14.2.3 106 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. 14.4.1 For door/ window/ clerestory window (D.S.R.2023,Vol.2,Code-14.4)14.4.1 107 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (D.S.R.2023,Vol.2,Code-14.5)14.5.1 108 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.2 Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (D.S.R.2023,Vol.2,Code-14.5)14.5.2 109 Renewing glass panes, with wooden fillets wherever necessary: 14.6.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (D.S.R.2023,Vol.2,Code-14.6)14.6.1 110 Renewing glass panes, with wooden fillets wherever necessary: 14.6.2 Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (D.S.R.2023,Vol.2,Code-14.6)14.6.2 111 Renewing glass panes and refixing existing wooden fillets: 14.7.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (D.S.R.2023,Vol.2,Code-14.7)14.7.1 112 Renewing glass panes and refixing existing wooden fillets: 14.7.2 Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm (D.S.R.2023,Vol.2,Code-14.7)14.7.2 113 Supplying and fixing new wooden fillets wherever necessary: 14.8.1 2nd class teak wood fillets (D.S.R.2023,Vol.2,Code-14.8)14.8.1 114 Supplying and fixing new wooden fillets wherever necessary: 14.8.2 Hollock wood fillets (D.S.R.2023,Vol.2,Code-14.8)14.8.2 115 Renewal of old putty of glass panes (length (D.S.R.2023,Vol.2,Code-14.9) 116 Refixing old glass panes with putty and nails (D.S.R.2023,Vol.2,Code-14.10) 117 Fixing old glass panes with wooden fillets (excluding cost of fillets)(D.S.R.2023,Vol.2,Code-14.11) 118 Providing and fixing 25 mm thick shutters for cup board etc. : 14.26.1 Panelled or panelled & glazed shutters : 14.26.1.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (D.S.R.2023,Vol.2,Code-14.26)14.26.1.1 119 Providing and fixing 25 mm thick shutters for cup board etc. : 14.26.1 Panelled or panelled & glazed shutters : 14.26.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (D.S.R.2023,Vol.2,Code-14.26)14.26.1.2 120 Providing and fixing 25 mm thick shutters for cup board etc. : 14.26.2 Glazed shutters :14.26.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws.(D.S.R.2023,Vol.2,Code-14.26)14.26.2.1 121 Providing and fixing 25 mm thick shutters for cup board etc. : 14.26.2 Glazed shutters :14.26.2.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws.(D.S.R.2023,Vol.2,Code-14.26)14.26.2.2 122 Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.28.1 20 mm diameter. (D.S.R.2023,Vol.2,Code-14.28)14.28.1 123 Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.28.2 25 mm diameter. (D.S.R.2023,Vol.2,Code-14.28)14.28.2 124 Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete : 14.31.1 150 mm (D.S.R.2023,Vol.2,Code-14.31)14.31.1 125 Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete : 14.31.2 125 mm (D.S.R.2023,Vol.2,Code-14.31)14.31.2 126 Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete : 14.31.3 100 mm (D.S.R.2023,Vol.2,Code-14.31)14.31.3 127 Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : 14.32.1 150 mm (D.S.R.2023,Vol.2,Code-14.32)14.32.1 128 Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : 14.32.2 125 mm (D.S.R.2023,Vol.2,Code-14.32)14.32.2 129 Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : 14.32.3 100 mm (D.S.R.2023,Vol.2,Code-14.32)14.32.3 130 Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : 14.33.1 250 mm (D.S.R.2023,Vol.2,Code-14.33)14.33.1 131 Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : 14.33.2 150 mm (D.S.R.2023,Vol.2,Code-14.33)14.33.2 132 Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : 14.33.3 100 mm (D.S.R.2023,Vol.2,Code-14.33)14.33.3 133 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (D.S.R.2023,Vol.2,Code-14.34) 134 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (D.S.R.2023,Vol.2,Code-14.75A) 135 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm (D.S.R.2023,Vol.2,Code-14.77) 136 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (D.S.R.2023,Vol.2,Code-14.78) 137 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-14.79) 138 Providing & fixing White vitreous china water closet squatting pan (Indian type) along with S or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. 14.80.1 Long pattern W.C Pan of size 580x440 mm (D.S.R.2023,Vol.2,Code-14.80)14.80.1 139 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-14.81) 140 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-inCharge (D.S.R.2023,Vol.2,Code-14.82) 141 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.(D.S.R.2023,Vol.2,Code-14.85) 142 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).(D.S.R.2023,Vol.2,Code-14.86) 143 Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). (D.S.R.2023,Vol.2,Code-14.87) 144 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix(D.S.R.2023,Vol.2,Code-15.2)15.2.2 145 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge (D.S.R.2023,Vol.2,Code-15.3) 146 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.15.7.4 In cement mortar (D.S.R.2023,Vol.2,Code-15.7)15.7.4 147 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):15.8.3 From brick work in cement mortar (D.S.R.2023,Vol.2,Code-15.8)15.8.3 148 Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : 15.10.2 i n cement mortar (D.S.R.2023,Vol.2,Code-15.10)15.10.2 149 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below(D.S.R.2023,Vol.2,Code-15.12)15.12.1 150 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. Metres(D.S.R.2023,Vol.2,Code-15.12)15.12.2 151 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-15.19) 152 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.1 For thickness of tiles 10 mm to 25 mm(D.S.R.2023,Vol.2,Code-15.23)15.23.1 153 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.2 For thickness of tiles above 25 mm and up to 40 mm (D.S.R.2023,Vol.2,Code-15.23)15.23.2 154 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: 15.34.1 T or L iron or pipe(D.S.R.2023,Vol.2,Code-15.34)15.34.1 155 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: 15.34.2 R.C.C.(D.S.R.2023,Vol.2,Code-15.34)15.34.2 156 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.39.1 Up to 10 mm thick (D.S.R.2023,Vol.2,Code-15.39)15.39.1 157 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.39.2 Thickness above 10 mm up to 25 mm(D.S.R.2023,Vol.2,Code-15.39)15.39.2 158 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :15.39.3 Thickness above 25 mm up to 40 mm(D.S.R.2023,Vol.2,Code-15.39)15.39.3 159 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 15.42.1 75 to 80 mm dia pipe( D.S.R.2023,Vol.2,Code-15.42)15.42.1 160 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :15.42.2 100 mm dia pipe (D.S.R.2023,Vol.2,Code-15.42)15.42.2 161 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :15.42.3 150 mm dia pipe (D.S.R.2023,Vol.2,Code-15.42)15.42.3 162 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 15.45.1 Up to 150 mm diameter (D.S.R.2023,Vol.2,Code-15.45)15.45.1 163 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 15.45.2 Above 150 mm dia up to 300 mm dia (D.S.R.2023,Vol.2,Code-15.45)15.45.2 164 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 15.45.3 Above 300 mm diameter (D.S.R.2023,Vol.2,Code-15.45)15.45.3 165 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(D.S.R.2023,Vol.2,Code-15.56) 166 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (D.S.R.2023,Vol.2,Code-15.57) 167 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 16.70.1 Made of G.I. wire of dia 4 mm (D.S.R.2023,Vol.2,Code-16.70)16.70.1 168 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 16.70.2 Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade (D.S.R.2023,Vol.2,Code-16.70)16.70.2 169 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.(D.S.R.2023,Vol.2,Code-16.71) 170 Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site. (D.S.R.2023,Vol.2,Code-16.72) 171 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (D.S.R.2023,Vol.2,Code-16.83) 172 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). (D.S.R.2023,Vol.2,Code-16.84) 173 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.(D.S.R.2023,Vol.2,Code-16.89) 174 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (D.S.R.2023,Vol.2,Code-16.91)16.91.1 175 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.(D.S.R.2023,Vol.2,Code-16.91)16.91.2 176 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. (D.S.R.2023,Vol.2,Code-16.93) 177 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (D.S.R.2023,Vol.2,Code-17.1)17.1.1 178 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid (D.S.R.2023,Vol.2,Code-17.2)17.2.1 179 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid (D.S.R.2023,Vol.2,Code-17.3)17.3.1 180 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern(D.S.R.2023,Vol.2,Code-17.4)17.4.1 181 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern(D.S.R.2023,Vol.2,Code-17.5)17.5.1 182 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern(D.S.R.2023,Vol.2,Code-17.6)17.6.1 183 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (D.S.R.2023,Vol.2,Code-17.7)17.7.1 184 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (D.S.R.2023,Vol.2,Code-17.7)17.7.2 185 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer(D.S.R.2023,Vol.2,Code-17.7A) 186 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 17.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm(D.S.R.2023,Vol.2,Code-17.9)17.9.1 187 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.2 Kitchen sink without drain board 17.10.2.1 610x510mm bowl depth 200 mm (D.S.R.2023,Vol.2,Code-17.10.2)17.10.2.1 188 Providing and fixing white vitreous china water closet squatting pan (Indian type) : 17.13.1 Long pattern W.C. pan of size 580 mm (D.S.R.2023,Vol.2,Code-17.13)17.13.1 189 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan (D.S.R.2023,Vol.2,Code-17.15) 190 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (D.S.R.2023,Vol.2,Code-17.16A) 191 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 17.19.1 10 litre (full flush) capacity-white (D.S.R.2023,Vol.2,Code-17.19)17.19.1 192 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 17.19.2 10 litre (full flush) capacity-coloured (D.S.R.2023,Vol.2,Code-17.19)17.19.2 193 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 17.20.1 White solid plastic seat with lid (D.S.R.2023,Vol.2,Code-17.20)17.20.1 194 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.(D.S.R.2023,Vol.2,Code-17.22) 195 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-17.22A) 196 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia (D.S.R.2023,Vol.2,Code-17.22B)a 197 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (D.S.R.2023,Vol.2,Code-17.23) 198 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (D.S.R.2023,Vol.2,Code-17.24) 199 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.2 Flexible pipe 17.28.2.1 32 mm dia. (D.S.R.2023,Vol.2,Code-17.28)17.28.2.1 200 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (D.S.R.2023,Vol.2,Code-17.31) 201 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete (D.S.R.2023,Vol.2,Code-17.78) 202 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-17.80) 203 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (D.S.R.2023,Vol.2,Code-17.81) 204 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 18.7.1 15 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.7)18.7.1 205 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall18.7.2 20 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.7)18.7.2 206 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall18.7.3 25 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.7)18.7.3 207 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.8)18.8.1 208 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.2 20 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.8)18.8.2 209 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.3 25 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.8)18.8.3 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.1 15 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.9)18.9.1 211 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.2 20 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.9)18.9.2 212 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.3 25 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.9)18.9.3 213 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.4 32 mm nominal dia Pipes (D.S.R.2023,Vol.2,Code-18.9)18.9.4 214 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.1 15 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.10)18.10.1 215 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.2 20 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.10)18.10.2 216 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.3 25 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.10)18.10.3 217 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.4 32 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.10)18.10.4 218 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 18.11.1 15 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.11)18.11.1 219 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 18.11.2 20 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.11)18.11.2 220 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.1 15 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.1 221 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.2 20 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.2 222 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.3 25 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.3 223 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.4 32 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.4 224 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.5 40 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.5 225 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.6 50 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.6 226 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.7 65 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.7 227 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.8 80 mm dia nominal bore (D.S.R.2023,Vol.2,Code-18.12)18.12.8 228 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.13.1 25 to 40 mm nominal bore (D.S.R.2023,Vol.2,Code-18.13)18.13.1 229 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.13.2 50 to 80 mm nominal bore (D.S.R.2023,Vol.2,Code-18.13)18.13.2 230 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (D.S.R.2023,Vol.2,Code-18.14) 231 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.1 25 mm nominal bore (D.S.R.2023,Vol.2,Code-18.17)18.17.1 232 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.1A 20 mm nominal bore (D.S.R.2023,Vol.2,Code-18.17)18.17.1A 233 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.2 32 mm nominal bore. (D.S.R.2023,Vol.2,Code-18.17)18.17.2Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.2 32 mm nominal bore. (D.S.R.2023,Vol.2,Code-18.17)18.17.2 234 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.3 40 mm nominal bore. (D.S.R.2023,Vol.2,Code-18.17)18.17.3 235 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.4 50 mm nominal bore (D.S.R.2023,Vol.2,Code-18.17)18.17.4 236 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.5 65 mm nominal bore (D.S.R.2023,Vol.2,Code-18.17)18.17.5 237 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.6 80 mm nominal bore (D.S.R.2023,Vol.2,Code-18.17)18.17.6 238 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.18)18.18.1 239 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.2 20 mm nominal bore (D.S.R.2023,Vol.2,Code-18.18)18.18.2 240 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.3 25 mm nominal bore (D.S.R.2023,Vol.2,Code-18.18)18.18.3 241 Providing and fixing gun metal non- return valve of approved quality (screwed end) :18.19.4 50 mm nominal bore18.19.4.2 Vertical (D.S.R.2023,Vol.2,Code-18.19)18.19.4.2 242 Providing and fixing gun metal non- return valve of approved quality (screwed end) :18.19.6 80 mm nominal bore18.19.6.2 Vertical (D.S.R.2023,Vol.2,Code-18.19)18.19.6.2 243 Providing and fixing uplasticised PVC connection pipe with brass unions :18.21.2 45 cm length18.21.2.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.21)18.21.2.1 244 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 18.31.1 100 mm diameter18.31.1.2 Class II (D.S.R.2023,Vol.2,Code-18.31)18.31.1.2 245 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 18.31.3 150 mm diameter18.31.3.2 Class II (D.S.R.2023,Vol.2,Code-18.31)18.31.3.2 246 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (D.S.R.2023,Vol.2,Code-18.33)18.33.1 247 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (D.S.R.2023,Vol.2,Code-18.34)18.34.1 248 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.42.3 Beyond 12 m and up to 18 m depth (D.S.R.2023,Vol.2,Code-18.42)18.42.3 249 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 18.46.1 15 mm nominal bore.(D.S.R.2023,Vol.2,Code-18.46)18.46.1 250 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.2 20 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.2 251 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.3 25 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.3 252 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.4 32 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.4 253 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.5 40 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.5 254 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.6 50 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.6 255 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.7 65 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.7 256 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.46.8 80 mm nominal bore (D.S.R.2023,Vol.2,Code-18.46)18.46.8 257 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.1 258 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.2 20 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.2 259 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.3 25 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.3 260 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.4 32 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.4 261 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.5 40 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.5 262 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.6 50 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.6 263 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.7 65 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.7 264 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.47.8 80 mm nominal bore (D.S.R.2023,Vol.2,Code-18.47)18.47.8 265 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (D.S.R.2023,Vol.2,Code-18.48) 266 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.49)18.49.1 267 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 18.50.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.50)18.50.1 268 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 18.51.1 15 mm nominal bore (D.S.R.2023,Vol.2,Code-18.51)18.51.1 269 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore(D.S.R.2023,Vol.2,Code-18.52)18.52.1 270 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore (D.S.R.2023,Vol.2,Code-18.53)18.53.1 271 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (D.S.R.2023,Vol.2,Code-18.53)18.53A 272 Providing and fixing PTMT bib cock of approved quality and colour.18.54.4 15 mm nominal bore, 90 mm long, weighing not less than 93 gms(D.S.R.2023,Vol.2,Code-18.54)18.54.4 273 Providing and fixing PTMT stop cock of approved quality and colour.18.55.3 Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gms (D.S.R.2023,Vol.2,Code-18.55)18.55.3 274 Providing and fixing PTMT pillar cock of approved quality and colour.18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms (D.S.R.2023,Vol.2,Code-18.56)18.56.2 275 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (D.S.R.2023,Vol.2,Code-18.63) 276 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (D.S.R.2023,Vol.2,Code-18.64) 277 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms(D.S.R.2023,Vol.2,Code-18.65) 278 Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :18.73.1 100 mm dia Ductile Iron Double Flanged (D.S.R.2023,Vol.2,Code-18.73)18.73.1 279 Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :18.73.2 150 mm dia Ductile Iron Double Flanged (D.S.R.2023,Vol.2,Code-18.73)18.73.2 280 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 18.74.1 15 mm nominal bore with 30cm length (D.S.R.2023,Vol.2,Code-18.74)18.74.1 281 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.18.74.2 15 mm nominal bore with 45 cm length (D.S.R.2023,Vol.2,Code-18.74)18.74.2 282 Cutting holes up to 30x30 cm in walls including making good the same: 18.76.1 With common burnt clay F.P.S. (non modular) bricks(D.S.R.2023,Vol.2,Code-18.76)18.76.1 283 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (D.S.R.2023,Vol.2,Code-18.77) 284 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc (D.S.R.2023,Vol.2,Code-18.78) 285 Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba. (D.S.R.2023,Vol.2,Code-18.79) 286 Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 18.82.1 80 mm diameter C.I. pipe (D.S.R.2023,Vol.2,Code-18.82)18.82.1 287 Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 18.82.2 100 mm diameter C.I. pipe (D.S.R.2023,Vol.2,Code-18.82)18.82.2 288 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 18.84.1 15 mm nominal bore(D.S.R.2023,Vol.2,Code-18.84)18.84.1 289 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 19.5.1 100 mm diameter (D.S.R.2023,Vol.2,Code-19.5)19.5.1 290 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 19.5.2 150 mm diameter (D.S.R.2023,Vol.2,Code-19.5)19.5.2 291 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (D.S.R.2023,Vol.2,Code-19.7)19.7.1.1 292 Supplying and fixing C.I. cover without frame for manholes : 19.18.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg (D.S.R.2023,Vol.2,Code-19.18)19.18.1 293 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg (D.S.R.2023,Vol.2,Code-19.20) 294 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 19.21.1 For pipes 100 to 250 mm diameter (D.S.R.2023,Vol.2,Code-19.21)19.21.1 295 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-charge: 19.24.1 Rectangular manhole 90x80 cm and 45 cm deep (D.S.R.2023,Vol.2,Code-19.24)19.24.1 296 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 19.29.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5(D.S.R.2023,Vol.2,Code-19.29)19.29.1 297 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (D.S.R.2023,Vol.2,Code-19.32)19.32.1 298 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 19.34.1 100 mm dia (D.S.R.2023,Vol.2,Code-19.34)19.34.1 299 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :19.34.2 150 mm dia (D.S.R.2023,Vol.2,Code-19.34)19.34.2 300 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)(D.S.R.2023,Vol.2,Code-21.1)21.1.1.1 301 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (D.S.R.2023,Vol.2,Code-21.1)21.1.1.2 302 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron (D.S.R.2023,Vol.2,Code-21.1)21.1.1.3 303 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (D.S.R.2023,Vol.2,Code-21.1.2)21.1.2.1 304 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (D.S.R.2023,Vol.2,Code-21.1.2)21.1.2.2 305 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (D.S.R.2023,Vol.2,Code-21.1.2)21.1.2.3 306 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side (D.S.R.2023,Vol.2,Code-21.2)21.2.1 307 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. 21.2.2 Pre-laminated particle board with decorative lamination on both sides(D.S.R.2023,Vol.2,Code-21.2)21.2.2 308 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)(D.S.R.2023,Vol.2,Code-21.3)21.3.1 309 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (D.S.R.2023,Vol.2,Code-21.3)21.3.2 310 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)(D.S.R.2023,Vol.2,Code-21.3)21.3.3 311 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 21.4.1 With stainless steel cover plate minimum 1.25 mm thickness(D.S.R.2023,Vol.2,Code-21.4)21.4.1 312 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 21.4.2 With brass cover plate minimum 1.25 mm thickness (D.S.R.2023,Vol.2,Code-21.4)21.4.2 313 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.21.12.3 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar (D.S.R.2023,Vol.2,Code-21.12)21.12.3 314 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge21.16.3 Polyester powder coated minimum thickness 50 micron aluminium(D.S.R.2023,Vol.2,Code-21.16)21.16.3 315 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (D.S.R.2023,Vol.2,Code-21.17) 316 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) (D.S.R.2023,Vol.2,Code-21.18) 317 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm (D.S.R.2023,Vol.2,Code-22.3) 318 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (D.S.R.2023,Vol.2,Code-22.5) 319 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. (D.S.R.2023,Vol.2,Code-22.6) 320 Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. (D.S.R.2023,Vol.2,Code-22.12) 321 Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (D.S.R.2023,Vol.2,Code-22.14)22.14.1 322 Grading roof for water proofing treatment with22.14.2 Cement mortar 1:3 (1 cement : 3 coarse sand)(D.S.R.2023,Vol.2,Code-22.14)22.14.2 323 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge (D.S.R.2023,Vol.2,Code-22.22A) 324 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.23.1 For vertical surface two coats @ 0.70 kg per sqm (D.S.R.2023,Vol.2,Code-22.23)22.23.1 325 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.23.2 For horizontal surface one coat @1.10 kg per sqm.(D.S.R.2023,Vol.2,Code-22.23)22.23.2 326 Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.(D.S.R.2023,Vol.2,Code-22.23A) 327 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures likebasement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturers specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (D.S.R.2023,Vol.2,Code-22.24) 328 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.(D.S.R.2023,Vol.2,Code-22.26) 329 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- inCharge. (D.S.R.2023,Vol.2,Code-25.4) 330 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. (D.S.R.2023,Vol.2,Code-25.8) 331 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate crossT of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 26.23.1 With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles(D.S.R.2023,Vol.2,Code-26.23)26.23.1 332 Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (D.S.R.2023,Vol.1,Code-2.34)2.34.1 333 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (D.S.R.2023,Vol.1,Code-2.35)2.35.1.1 334 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration(D.S.R.2023,Vol.1,Code-2.35)2.35.2.1 335 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (D.S.R.2023,Vol.1,Code-2.35)2.35.3.1 336 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (D.S.R.2023,Vol.1,Code-2.35)2.35.4.1 337 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (D.S.R.2023,Vol.1,Code-2.35)2.35.5 338 Cleaning of Chocked Main Holes of Sever lines including supply of all materials,Labour,T&P e.t.c. 339 Emptying and Cleaning of Septic Tank including labours,tools,and Machines e.t.c. 340 S/F of I.S.I. Marked Cistern function cylinder of wall mounted Europian Type W.C.Sheet including supply of all materials,Labour,T&P e.t.c. Make-Hindware,Pareware Please Enable Macros to View BoQ information
Contract Date: Jan 13, 2026 Contract Value : 2.22 Lakh
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
35.
Defence #9358039 Technical Bid
Tender For Invitation Of Quotation Fo Renewal Of Five Year Annual Maintenance Contract Contract For Maintenance Of 06 X Tps; 1 Fire Alarm System Nos. 2 Electronics Surveillance Nos. 3 Camera Nos. 4 Gen Set & Associated Eqpt & Services Nos. 5 HVAC System Nos. 6 Building Management System Nos. 7 Earthing Pits & Related Eqpt Nos. 8 Transformer & Related Eqpt Nos. a) Disconnect the power supply to the AHU and place “under maintenance” board for the same. b) Clean the AHU with lint free cloth. c) Grease the bearings of the blower and motor if required. d) Check the motor terminals for tightness, rectify if required e) Clean the drain tray of cooling coil. f) Tighten the base bolts of the blower, motor & Pumps etc. g) Check the V- belt for tightness, rectify if required. h) Check for gas leakage, if any, rectify the same. i) Check the refrigeration gas into the system and top up if required. j) Reconnect the power supply and take trials to ascertain proper working. k) Run the blower and check for leakages through the doors and duct joints of AHU. l) Check dampers for smooth operation and check their locking arrangements. m) Cleaning of oil filter of compressor n) Cleaning of suction line strainer or compressor / AHU o) Checking of correctness and calibration of all safety and automatic controls p) Cleaning of contactors of Chiller plant if required. q) Record all the observation on Preventive Maintenance Check list ELECTRICALS 1 Modular type switches / Sockets / Fan regulators / Telephone / LAN / TV front plates and anodised GI boxes/Buzer Legrand MK India / Anchor/ Wipro/Crabtree 2 FRLS insulated Copper conductor wires Finolex / RR Kabel/KEI 3 FRLS conduits (PVC/MS) & accessories BEC/ AKG/ Precision 4 Metal Clad sockets Lagrand, Hager, Schneider 5 MCBs Lagrand, Hager, Schneider, Siemens 6 CB distribution boards Legrand (Equinox3)/ Hager (Novello)/ Schneider (Acti9) 7 Light fixtures Philips/ Trilux/ Wipro 8 Exhaust fans Havells/ Crompton/ Usha/ Almonard 9 Ceiling Fans Havells/ Crompton/ Usha/ Almonard 10 Buzzers Same make of moduler 11 Telephone cables Deltaon, Mazda, Finolex, RR Kabel 12 MV switchgear Legrand/ Schenider/ L&T/ ABB/SIEMENS 13 Measuring instruments Enersol/ Trinity/ Conzerv 14 MV Panels CPRI approved manufacturers having type test report for short circuit upto 70kA, Internal Arc test, IP test & temp rise issued recently (not earlier than two years) 15 HT cables Finolex, KEI, Torrent, RPG, CCI 16 MV & Control cables RR Kabel/KEI/ FINOLEX 17 Cable Glands Comet/ HMI/ SHYAAM/Dowell's 18 Cable Lugs Dowell's/ 3D/ Hex 19 GI pipe TATA/ Jindal Hisar 20 Maintenance free earth station Universal, Erico, OBO 21 TVSS Hager/ ABB/ Obo-Bettermen/ Schenider 22 Vacuum circuit breakers & SFU Siemens, Schenider, ABB (Relays shall be same make as breakers), L&T, Alstom, 23 Capacitors Neptune, Epcos, Schenider, Lagrand, ABB, Unistar, L&T, Siemns, 24 LT CTs / PTs AE, Kappa 25 Electronic Meters L&T/ HPL/ Conzerv/ AE/ Meco 26 Power factor control relay Alacrity, Beluk, Neptune, L&T, Epos, Schenider 27 Heat Shrinkable jointing kits Raychem, 3M, 28 Battery / Battery charger Amara Raja, Exide, , Nalco 29 Capacitor switching conductors ABB, Merlin Gerin, Siemens, L&T, Lovato 30 Power system relays AMM, Siemens, Alstom, Areva, GE, L&T 31 Twisted pair / control cables Finolex, LEP India, RPG 32 Street light fixtures Philips, Wipro 33 Telephone sockets MK India, Legrand, Delton 34 PVC conduits & accessories Sudhakar, AKG, Precision 35 ACBs / MCBs/TPN SFUs L&T, GEC, Alstom, Siemens, ABB 36 Underground cables CCI, RPG, KEI, Unistar, Finolex 37 Fire extinguishers Minimax, Vijay, Safex, Ceasefire 38 Horizontal centrifugal fire water pumps Kirloskar, Beaconweir, Mather Platte, Groundfos 39 Raw water / treated water / Soft water pumps Kirloskar, Grundfos 40 Motors Kirloskar, Crompton, Siemens, ABB 41 Pressure switch Switzer, Infoss, Danfos 42 D.I. pipes Electrosteel, Lanco, Kalahasti 43 Mechanical joint fittings Electrosteel, Orient rubber 44 Underground pipe protection IWL India Limited 45 CI Slim seal butterfly valves Audco, Advance, ZOLOTO, Sant value 46 Electrically operated butterfly valves Audco, Sant value, Advance, ZOLOTO 47 Dual plate check valves (Nonreturn) Audo, Advance 48 Gun Metal gate valves Leader, Zoloto 49 Earth station Indlec, Erico 50 Sluice Valves Audco, Kirloskar 51 Air valves Kirloskar, Sant 52 Valves Audco, Zoloto 53 MS pipe TATA, Jindal Hisar 54 LED Indications Siemens, Schenider, Crompton Greaves, GE, ABB (Relays shall be same make as breakers), L&T, Alstom, 55 Relays AVK SEG, Woodward, DEIF, 56 Anti-vibration pads GERB, Dunlop, MRF 57 Pressure Gauges FEBI, H.Guru, Bicol 58 Digital flow meter Kent-Aqua Metro (Sansang) 59 MCCB Siemens, L&T, ABB, Schenider 60 Geysers Recald, Usha Lexus, Crompton Greaves 61 FRLS Copper conductor wires Finolex, RPG 62 Multi Detectors Siemens, Edewarls, Honeywell 63 Control / Monitor modules Siemens, Edewarls, Honeywell 64 Manual call Points & loop Siemens, Edewarls, Honeywell Sounders 65 Faultlsolators Siemens, Edewarls, Honeywell 66 Siren Siemens, Edewarls, Honeywell 67 M C P Siemens, Edewarls, Honeywell 68 Control panel - FAS Siemens, Edewarls, Honeywell 69 Repeater Panel Siemens, Edewarls, Honeywell 70 BATTERY(SEALED MAINTENANCE FREE) EXIDE, AMCO, STANDARD, AMRON, 71 UPS Emersion, APC, Luminous 72 SENSOR Hager/ Legrand/ Siemens/ Schneider FIRE ALARM AND DETECTION SYSTEM Addressable, Digitally, Conventional Fire Detection System (UL Listed) 73 Fire Alarm Control/ Repeater Panel Honeywell (Notifier) / Edward 74 Detector & Devices (Hooter, MCP, Control/ Relay/ Monitor Module, Fault Isolators etc.) Honeywell (Notifier) / Edward 75 Response Indicator OEM recommended 76 PA System Honeywell (Notifier) / Edward/ Bosch/Armatel 77 Talk Back System Honeywell (Notifier) / Edward/Bosch/Armatel Audio Video System for Auditorium 78 Acoustic Ceiling Himalaya Acoustic/Acoustica One/Anuton/Armstrong 79 Acoustic Wall Panelling Himalaya Acoustic /Acoustica One/Anuton/Armstrong 80 Sound Reducing Door Pacific Fire/Dexun/Navair/ Himalaya Acoustic 81 General Lighting Frusttumwatt UK /Igguzini/Zumtobel/Phillips 82 Video Door Phone System Legrand/ Kocum/ Commax/ TCS 83 Telephone Equipment Panasonic/ Huawei/ Motorola 84 EPABX Matix/ Panasonic/ Alcatel/ NEC/Siemens 85 Krone Boxes Krone/ Legrand/ Panduit/ Systimax IT -NETWORKING 86 LAN/ Cat-6 Cable, Patch Cord, Patch Panel, Fiber Cable, LIU, Pigtails etc. Legrand/ Systimax/ Panduit /Cisco 87 Network Switches Cisco 88 Racks Legrand/ Rittal AIR CONDITIONING 1 (a) Condensing units (DX) Blue Star / Carrier / Voltas / ETA / Hitachi / Daikin (b) CHILLERS Carrier / Dunhambush / TRANE/YORK / Mcquary (Kirloskar) (c) VRF units Mitsubishi Electric / Daikin / Carrier / Toshiiba (d) Precission A/C Climaventa / Emerson / Schneider 2 Pumps Beacon / Kirloskar / Mather&Platt / Grundfos / KSB / ITT / Armstrong 3 Air Handling Units System Air / Blue star / Zeco / Edge Tech/ETA / Citizen (Ahemadabad) / caryaire / Suvidha 4 Ventilation Units Blue Star / ETA / Krugger / Nicotra / System air 5 Fans for AHUs and Ventilation Units Krugger / Nicotra / Camfri / EBM Papst 6 Inline fans Krugger / Nicotra / Camfri / EBM Papst 7 Motors ABB / Crompton / GE / Kirloskar / Siemens 8 Hot Water Generator KEPL / Emerald / Rapid Cool 9 Pan Humidifier KEPL / Emerald / Rapid Cool 10 Copper pipes Mandev/ Totaline 11 MS Pipes Tata / Jindal Hisar / Zenith / SAIL 12 Butterfly valves Audco / Intervalve / Advance Cra weley & Ray 13 Gate valves / Globe valves Leader / Sant / Audco 14 Check valves Advance / Intervalve / Audco 15 Y Strainers with magnetic screen Sant / Lehry / Advance / Zoloto / Emerald / DS Engg. 16 Expansion tank Syntex 17 Thermometers Fiebig, Mumbai / Waree. Instruments Ltd, Mumbai / Forbes Marshall P.Ltd, Pune 18 Pressure Gauges Fiebig, Mumbai / Waree. Instruments Ltd, Mumbai / Forbes Marshall P.Ltd, Pune / H Guru 19 Balancing Valve Castle / Advance/ Arrow/ Tour & Anderson 20 Way motorized valves Honeywell / Sauter / Jhonson / Siemens / Stefa 21 GI Sheets SAIL / TATA /JINDAL HISAR / HSL 22 Spiral ducting GP Spiro / Helical Tubes 23 Fiber glass insulation UP Twigs / Kimmco / Owens Coring / Beardsells 24 Nitril rubber insulation / XLPE insulation Armacell / K Flex / A Flex / supreme / Thermoflex 25 Automatic Air Vents Anergy 26 Grilles / Diffusers / Volumcecontrol Dampers / Collar Dampers / Louvers Caryaire / Revistar / Airmaster / Airbreeze 27 Vibration Isolators Dunlop (I) Ltd / Resistoflex P. Ltd, Noida 28 Cable Trays Pantry Systrems P Ltd, Hyd / ProfabEngineers P Ltd, Sec’bad / Indiana Cables Trays Corporation, Mumbai / Legarand (Cablofil) 29 Electricals panels Panel Builders having CPRI approved type test reports for short circuit & inhouse temp rise issued recently (within last two years) with approved Switchgear 30 MV Switchgear Siemens / Schneider / L&T / GE / Legrand 31 LT Cabling Universal / Unistar/ NICCO / Finolex / KEI / Torrent Cables Ltd – Vadodara 32 Fire Dampers Caryaire / Ravistar / Airmaster / Air Breeze / Green Check (UL Rated) 33 Damper Actuators Belimo Actuators (I) P.Ltd, Mumbai / Siemens / Honeywell 34 Digital Temp & RH Indicators Siemens / Honeywell / Johnson 35 Grills / Diffuser Ventura / Airmaster / Systemair / Caryaire
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 1
36.
Public Administrative Department #9337259 Technical Bid
Tender For Inverting Quotation For Non Csr Item For Installing Traffic Signal And Solar Blinker In The City- 1 Supply of 300mm dia LED Retrofit LED based comp site solid state laminate module using ultra bright low power LED with high conversion efficiency and multiple drive circuit streams to ensure fail back configurations and minimum failure consumiting of 10 watt eacpower having horizontal LED arrangement. 2 A) For Red luminous intensity of LED 160m cd min. viertical angle 70 degree min 3 B) For amber luminous intensity of LED cd min. vertical angle 24 degree min. 4 C) For Green luminous intensity of LED 120 cd min. vertical angle 24 degree min 5 D) For pedistitrain signal luminous intensity of LED 70 cd min. vertical angle 24 degree min. Aspect Red signal 6 E) For pedistitrain signal luminous intensity of LED 70 cd min. vertical angle 24 dgree min. Aspect Green signal 7 Supply of 300mm dia polycarbonate lamphead assemly 8 Mounting of 300mm dia FRP/polycarbonate traffic signal head on the pole and wiring the same the tag block in pole cap/junction with type plug termination etc complete (i) Cantilever polse(A) Signle aspect. 9 Supply of Microprocessor based automatic traffic signal controller housed in MS 16 SWG fabrication water proof, rust proof and dust light double walled cabinet and switch box with locking arrangements with lock and keys. Suitable for mounting on a pedestal incorporating the following Minimum 8 plans and 8-phase with manual controlling and blinker mode. Minimum 7 days clock and signal lines suitable for isolated type traffic junction 10 Supply of traffic signal pole assembly complete with 100mm inner dia, pipe (B Class) including providing M.S. base plate of size 200mm*200mm *100mm thick switch with bottom of the pole flanged FRP cap at top, the pole painted with 2 coats of zinc chromate primer and in addition bituminous painting for the bottom 1.5m, portion of pipe, providing cable entry hole etc. complete. 11 A) 6.00Mtrs. Loge Pole 12 B) Cantilever Pole 9meter long 13 Installing the controller on C.C. 1:2:4 pedestal 60cm above G.L. of suitable size testing and commissioning with any number of phases including providing earth station as per I.S. rules etc.complete. 14 Erection of traffic signal pole in 60cm * 60cm 1.00m deep pit with 11:5:3 cement concrete and C.C. plastering, curing. 15 A) Normal Pole (6mtr hight) 16 B) Cantilever Pole 17 Local earthing of signal / street light pole when use as traffic pole with 10m length of 10 SWG G.I. Wire loop being kept at minimum of 2m below G.I. etc. complete as per I.S. Rules 18 Painting of signal pole with 2coats of synthetic enamel paint approved colour 19 A) Normal Pole (6mtr hight) 20 B) Cantilever Pole 21 Supply and laying of multicore aurmourd Flexible/solid core copper conductor PVC insulated & sheatered cable 1 sq.mm. c/s area as per I.S. 22 A) 7Core (Approximate 23 B) 14Core (Approximate) 24 Excavation of trench 60cms wide and 1.00 deep 25 laying cable on side shoulder, including spreading sand providing bricks lining for cable protection refilling the trench, leveling, clearing the site etc. complete without top finishing and reinstatement 26 Exacavation of damber road 27 Providing and fixing MS 16 guage junction box with removable base plate with wooden plant inside for signal/three phase MSEDCL service connection with main switches, distribution board, indicators with necessary fixing accessories as per I.S. std etc. complete 28 Providing and fixing junction box on signal/street pole for cable connection including looping taking cable through G.I. pipe upto junction box from ground leave etc. complete 29 Supply of installation in material like condults reducer, coller, adopter B.T.W. wire flexible piper etc 30 Supply and Installation and commissioning of Digital traffic signal balance time indicator with Red, and Green Phase timing in second, with super bright LEDs seven segment of size 8 height 4 width, 3 digit Red LED display having 250 med Luminius output of each digit and leading zero super fine with red transparent acrylic in front side of M.S. 18 SWG 31 supply& laying of 50mm dia DWC pipe 32 Supply & Fixing of 50mm dia GI Pipe 33 Solar Blinker with pole 34 Supply of6mtr long traffic signal pole assembly complete with 100mm dia. Pipe class B including providing M.S.base plate of size 200mmx200mmx6mm thick welded with bottom of the pole painted with rubber paint below ground level and red oxide on exposed surface and finishing with traffic yellow enamel paint in two coats complete as required etc complete. 35 Supply of LED mounted digital traffic signal cantiliver pole of GI (ERW) rectangle type/round type including LED module fixtures, control, unit, driver relays, cables & wires necessary asccessories as required Vertical Pole shaft: 150mm x150 mm x 5 mm (Thickness) and 6.7 MT height withHorizontal Arm: 150 x 1 0 0 x 3 . 5 - 4 mm thick and 6.57M length. Fixture Arm for Aspects at Center: 80mm x 80mm x 3mm x 1300mm. Base Plate: 400 x400 x 20mm welded and painted in appropriate colour etc completre. 36 Installation and commissioning of control and LED module fixtures on above catiliver pole with fitting accssories as specified complete 37 Supply of 300 mm dia signal LED Retrofits consisting of High Efficiency, High reliability imported super brightness LEDs with light output brightness up to 256 cd with 10w. The operation voltage is 230 V AC ( +/- 15%)having on board driver & work in the range of 180 VAC to 270 VAC having operating temperature range 0 to 50 degree celsius. It is having fuse transient voltage supressor & short circuit over voltage & water leakage protection etc assembly with all materials. 38 a.Vehicular RED Round with more than 177 LEDs 39 b.Vehicular AMBERRound with more than 177 LEDs 40 c.Vehicular GREEN Arrow with more than 90 LEDs 41 d.pedstrian RED (Stopman) with more than 90 LEDs 42 e.pedstrian GREEN (Walkman) with more than 90 LEDs 43 Vehicular Amber Arrow with more than 90 LEDs 44 Supply of 300 mm dia polycarbonate lamp head assembly with polycarbonate visor lens, hood, extra polycarbonate back cover etc complete 45 Installation & mounting of lamp head assembly on thestraight 6m pole etc complete. 46 Installation & mounting of lamp head assembly on thestraight 13.27 m cantiliver pole etc complete. 47 Supply and laying of copper conductor appropriate PVC insulated 1.5 sq. mm. armoured cable in pre laid conduit as follow 48 a.2 Core Cable 49 3 core armoured shilded cable 50 Supply of Microprocessor basedATCS compatible traffic signal controller shall be equipped with GPS including providing of cabinet and other accessories etc complete with wired communicationtopology for distributed digital control of various node controllers installed on poles this features is required for using only twocable INSTEAD for traditional multi core cables etc complete 51 Installation of Master Controller 52 Supply ofNode controller on each pole for termination of control cables with topology base NODE card for lamp connection as digital distributed signal (DDC) microcontroller basedETC. COMPLETE. 53 Installation of Controller on pole with testing and commissioning with any no. of phases including providing earth station as per IS rules etc complete 54 Supply of COUNT DOWN TIMER (CDT) alfanumeric on traffice signal Pole of digit size 8 & should show verious TRAFFICE RELATED SLOGAN MESSAGES IN ENGLISH & MARATHI during the RED signal watting period 55 Installation testing and commissioning of CDT 56 Supply of installation material like conduits, reducer, collar, adoptor, BTW wire, flexible pipe etc complete 57 SupplyofMaster Controller - Innovative Traffic Controller having Master - Slave Configuration with Wireless (ISM Band), Working Voltage 12V DC-Solar Power Compatible, (inbuilt back up and auto charging facility) Wireless Operation with 16 lines per Master/Slave.System Clock with auto Time Correction Integrated Real Time Clock With GSM interface capable to communicate web monitoring, Inbuilt manual actuated auto flash provision, Pole Mountable, Lamp Intensity Control, Upgradable for cable less corridor synchronization, housed in MS 16 SWG fabricated box with powder coated finish in appropriate color, water proof, weather proof, dust tight, including all fittings with all features and facilitites as per technicalspecificationsetc complete 58 Installation, Testing and Commissioning of Master Controller 59 Supply of Slave Controller - operate on command of Master Controller with required no. of optically isolated solid state lamp driving outputs, input provision for four optically isolated Vehicle detector interface. Working Voltage - 12 V DC - Solar Power Compatible with inbuilt back up & charging facility,housed in MS 16 SWG fabricated box with powder coated finish in appropriate color, water proof, weather proof, dust tight, including all fittings etc complete. 60 Installation, Testing and Commissioning of slave controllers 61 Supply of reverse countdown timer two & half digit, dual color (Green & Red) Red color for Red display and Green color for green display, character height 8, visible in day light from (300 meters and readable from 100 meters housed in powder coated MS box complete.) 62 Installation, Testing and Commissioning of Count Down Timer 63 Supply and Connecting of multy core X0.5 sq. mm copper conductor tintedsolar cable inclusive of work of jointing &connecting with signal system (Slavecontrollers, Downcounters, traffic signalaspects & R/F modules). 64 Supply of medium gauge (class B) 6.00mtr Long std traffic signal pole assembly complete with 80mm Dia including base plate of size 200*200*10 mm thick welded at bottom as per I.S 1239 with approved synthetic enamel paint complete. 65 Supply of 200 mm dia LED blinker (Amber blow retrofit) with inbuilt flasher and battery charging unit, maximum power consumption upto 10W ± 10%, on board driver, universal input voltage facility, with inbuilt 7AH lithium battery backup provision so as to back up for 24 hours autonomy housed in Polycarbonate assembly with visor lens and required fittings etc complete. 66 Supply of 300 mm dia LED blinker (Amber blow retrofit) with inbuilt flasher and battery charging unit, maximum power consumption upto 10W ± 10%, on board driver, universal input voltage facility, with inbuilt 12AH lithium battery backup provision so as to back up for 24 hours autonomy housed in Polycarbonate assembly with visor lens and required fittings etc complete. 67 Supplying, installing, testing and commissioning of solar panel comprising high efficiency poly-crystalline / multi crystalline photovoltaic cell 30Wp, 12V with necessary clamps and elevated slanting structure for mounting frame should be made of MS angle 30mm*5mm with one coat of red oxide and two coats of synthetic enamel paint etc complete. 68 Supplying, installing, testing and commissioning of solar panel comprising high efficiency poly-crystalline / multi crystalline photovoltaic cell 50Wp, 12V with necessary clamps and elevated slanting structure for mounting frame should be made of MS angle 30mm*5mm with one coat of red oxide and two coats of synthetic enamel paint etc complete. 69 Erection of above pole incement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. X 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) and installation, testing & commissioning of blinker with all accessories, local earthing to the pole, fittings etc complete. 70 Supply of LED mounted digital traffic signal cantiliver pole of GI (ERW) as required Vertical Pole shaft: 150mm x150 mm x 5 mm (Thickness) and 6.7 MT height withHorizontal Arm: 150 x 1 0 0 x 3 . 5 - 4 mm thick and 6.57M length. Fixture Arm for Aspects at Center: 80mm x 80mm x 3mm x 1300mm. Base Plate: 400 x400 x 20mm welded and painted in appropriate colour etc completre. 71 Making Horizontal Directional Drill / Bore of 150 mm dia and depth up to 1.5 mtr in soft soil and laying 150 mm HDPE pipe etc. complete as per specification
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
37.
Power #9231122 Technical Bid
Construction Of 220Kv Gis Substation, Sector-75A, Gurugram -- 1 220kV SystemThe 245kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement with 7 bays (2 No. 100MVA 220/33kV transformer bay, 1 no. bus-coupler and 4 nos. feeder bays). Space for future 1 No. transformer bay and 2 No. Line bays and jointing plugs shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 220kV, 3-phase, 50 HZ 50kA fault level shall be of the indoor metal-enclosed type, comprising of following items.245kV, 2000A, single 3 – ⏀ or three 1 –⏀SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000Asingle 3 – ⏀or three 1 – ⏀ SF6 gas insulated switchgears, each Bus Bar comprising of:-i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.ii) Three, 2-core, single phase or single 3 – ⏀ ,2 core each phasevoltage transformers/ PTs.iii) 2000A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 –⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.iv) 2000A, One high speed 3 – ⏀or three 1–⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms. 2 245kV, 2000A, single 3 – ⏀or three 1 –⏀ , Bus coupler bay module, consisting of 2000Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, comprising of:i) 2000A, One 3 – ⏀or three 1 – ⏀ , SF6 gas insulated circuit breaker, complete with operating mechanism.ii) Three, 5-core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 2000A, Two sets of single pole, group operated isolator/disconnector switches each with single pole, group operated earthing switch and complete with manual and motor driven operating mechanisms.iv) Each GIS compartment with gas monitoring device, pressure switch etc. as required.v) Terminal boxes/ Local Control Cubicle.vi) Interconnecting wiring/ piping.vii)Grounding, support structures and platforms. 3 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transformer feeder circuit breaker bay module,consisting of 1250Asingle 3 – ⏀or three 1 – ⏀SF6 gas insulated switchgears, for transformer, each comprising of:-i) 1250A, One 3 – ⏀or three 1 –⏀ , SF6 gas insulated circuit breaker, complete with operating Mechanism.ii) Three, 5-core, single phase current transformers (450-300/0.577-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one 3 – ⏀or three 1 –⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix) Grounding, support structures and platforms. 4 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transmission line feeder circuit breaker bay modules, consisting of 1250Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, each comprising of:-i) 1250A, One 3 – ⏀or three 1 – ⏀ , SF6 insulated circuit breaker, complete with operating mechanism.ii) Three, 5- core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one normal and one high speed 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix)Grounding, support structures and platforms. 5 a) 220kV XLPE Copper cables (4X1CX400mm2) to connect 220kV side of 100MVA Transformer with GIS(approx.) 6 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX400mm2). (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 7 a) 220kV XLPE Copper cables (4X1CX1000mm2) to connect 220kV transmission line feeders with GIS (approx.) 8 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX1000mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 9 Ventilation system (AHU) to accommodate in designated room in GIS hall as per Annexure-V as it is already an integral part of the ventilation system 10 33kV SystemThe 36kV SF6 Gas Insulated Switchgear for three phase system shall have single bus bar arrangement with 26 bays (4 No. Transformer I/C bays from two 100MVA Transformers, 2 No. bus-sectionalizer bays, 16 nos. feeder bays, 2 No. T/F bays for Auxiliary Supply and 2 No. Capacitor bank bays). Space for 12 Nos. future bays (2 No. I/C of 220/33kV T/F bay, 8 No. line bays and 1 No. capacitor bank, 1 No. bus-sectionalizer bay for future) shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 Gas Insulated Switchgear rated for 33kV, 3-phase, 50Hz, 31.5kA for 3 sec. fault level shall be of the indoor metal-enclosed type, comprising of following items. 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Bar comprising of (single bus for each T/F with bus sectionaliser) :- i) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in single bus system.ii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.iii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.iv) Interconnecting wiring/ piping.v) Grounding, support structures and platforms. 11 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus sectionaliser, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Sectionaliser comprising of :(1 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for sectionaliser bay.ii) Three, single-core, single phase current transformers (2000-1000/5A)iii) Two sets of 2000A, two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) Two sets of Three, 2-core, single phase or single 3 – ⏀, 2 corevoltage transformers/ PTs.v) Two sets of 2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.vi) Two sets of 2000A, high speed 3 –  or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.viii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.ix) Interconnecting wiring/ piping.x) Grounding, support structures and platforms 12 36kV, 2000A, single 3 – ⏀ or three 1 –⏀, Incomer transformer bay modules, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, for 100MVA, 220/33kV transformers, each comprising of: - (2 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for incomer bay from 220/33kV transformer.ii) Three, 4-core, single phase current transformers (2000-1000/0.577-5-5-1A)iii) 2000A, Two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv)2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc..vii) Interconnecting wiring/ piping.viii)Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 13 36kV, 630A, single 3 – ⏀ or three 1 –⏀, Transmission line feeder circuit breaker bay modules, consisting of 630Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each comprising of:- (8 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers (600-300/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 14 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated Capacitor Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F)i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers(400-300/5-5A)iii)630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 15 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated S/Stn Transformer Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, single phase 2-core current transformers (60-30/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi)Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 16 33kV XLPE copper Cable (6X1Cx1000mm2) for connecting 33kV side of each I/C of 220/33kV transformer with GIS. (Two cables shall be used in each phase for each I/C, i.e. 2 Runs per phase x 3 no. Phase x 4 no. I/C) (approx.) 17 Single phase Termination kit for both end for 33kV XLPE copper Cable (1cx1000mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 18 33kV XLPE copper Cable (3cx300m2) for connecting 33kV capacitor bank bay(approx.) 19 Three phase Termination kit for both end for 33kV XLPE copper Cable (3cx300mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 20 33kV XLPE copper Cable (3cx95mm2) for single ckt. for station transformer(approx.) 21 Three Phase Termination kit for both end for 33kV XLPE copper Cable (3cx95mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 22 100 MVA 220/33 kV Power T/F along with10% extra T/F oil 23 NIFPES for 220/33 kV Power T/F 24 220 kV Surge Arrestor 25 33 kV Surge Arrestor (Including Capacitor Bank) 26 220 kV NCT (450-300/1A) 27 33 kV NCT For 220/33kV T/F (2000-1000/5A) 28 220 kV CVT For Line 29 220kV C&R Panels with SASCkt breaker control Panel with auto reclose & line Protection Panel 30 Ckt breaker control Panel without auto reclose and Transformer protection panel (for both HV & LV side of 220/33kV T/F)(each T/F have 2 no. 33kV Incomer) (1 No. for each T/F) 31 Ckt breaker control Panel without auto reclose and Bus Coupler cum Bus Bar Protection panel (Double Bus bar ) 32 Time synchronizationequipment 33 1 X 21.744 MVAR 33 kV rating Capacitor Bank along with Str. & allied equipments ( NCTs Series Reactor etc.) as perspecification 34 33 kV Line and Earth switch for Cap Bank (630 Amp.) 35 220V 200 AH Tubular Type Lead Acid San Container Battery 36 220 V 200 AH SMPS Battery charger 37 220 V D.C.D.B. 38 415 V LT AC Distribution Board 500 A 39 33/0.4 kV Station T/F 200 KVA 40 100 KVA DG Set along with associated accessories 41 EOT-Crane as per clause 3.10.7 Section-1 and Clause 29.0 of GIS Specification and as per EOT crane specification.(10T) 42 1.1 kV Copper Control Cable Armoured (FRLS type) for 220 kV bays of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 43 1.1 kV Copper Control Cable Armoured (FRLS type) for 33kV side of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 44 650/1100 Volts 3.5 core 240 mm2 aluminum power cable from Aux. T/F to ACDB 45 650/1100 Volt 3.5 core 70 mm2 aluminum cable for oil filtration set. 46 650/1100 Volt 4 core 16 mm2 armoured copper power cable for MLDB etc and other cable required as per contract. 47 Grounding system of the substation. Earthing Mat Material. The earth mat will be designed / quoted for soil resistivity of 50m. In case soil resistivity is more than 50m then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item.(9300 sq meter (approx) . Note:- Earthing of sub-station and equipments should be in line with HVPNL Tech. spec. and IEEE-80 considering fault and shock duration of 1 sec. 48 Fire Fighting equipments as per section-6:22.5 Kg Capacity FE CO2 type, Trolley Mounted 49 25 Kg Capacity FE DCP type, Trolley Mounted 50 DCP 9 Kg Capacity, Wall mounted 51 FE CO2 6.5 Kg Capacity, Wall mounted 52 DCP 6 Kg Capacity, Wall mounted 53 Foam Type 9 Litre Capacity, Wall mounted 54 Water CO2 9 Litre, Wall mounted 55 Fire Buckets(12 No.s with stand in one set) 56 Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications. 57 Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section 7 of the specification 58 (A) Supply and installation of 35W LED tube fitting on tubular steel poles along Fencing/ boundary wall at a distance of 30 meter including all accessories, cables etc. as per clause 16.0 of section 7 of the specification. 59 (B)Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 60 Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 61 High wall type split AC unit of 2 Ton capacity for computer room (2 no.) and C&R Panel room (4 no.) (as per technical specification) 62 Complete substation automation system for 220/33 kV substations including hardware (along with transducers)& software for present Bays and software for future bay along with associated equipment for the bays as defined in the technical specification, section sub-station automation system) as per technical specification. The scope for present and future is as under:- 220kV System: Present Bays: Line bays=4 T/F bays =2 Bus coupler =1 Future Bays Line bays=2 T/F bays =1 Bus coupler =033kV System: Present Bays: Line bays=16 T/F I/C bays =4 Bus Sectionliser bay =2 Capacitor bay =2 & Station T/F bay=2 Future Bays Line bays=8 T/FI/Cbays =2 Bus Sectionliser bay =1 Capacitor bay =1 & Station T/F bay=0 63 Computer system (SFF) with:Intel Core i5 processor with 11th generation or higher, 1x16GB DDR-IV RAM 2933 MHz or higher expandable upto 64 GB, 1 TB SSD or higher, 19.5” or higher TFT LCD Display (Backlit LED), Preloaded OS: Windows 11 Professional64-bit OEM or higher, with UPS (600VA offline UPS system 1x7AHx12V, MS-Office 2021 standard perpetual licensees or higher, etc. 64 Mono chrome Multi-functional Printer, A-4, 25 PPM, Copy & Scan function, Networking & Wi-Fi both, atleast 1 input tray 65 BOM FOR SAMAST COMPLIANT IEM ( ON SEPARATE CUBICLE) FOR 33 KV I/Ci. 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS (02 no. for each 33 KV Incomer) 66 Testing of IEM System from NABL accredited lab 67 Wired Indoor Meters Panel suitable for 8 meters 68 16 P Industrial Grade un-managed Network switch 69 Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 70 Cat-6 cable-unshielded 71 PVC conduit Pipe - 3/4 with accessories for Cat-6 cable lot Lot (In line with cat-6 cable) 72 Armored Fibre Optic Cable (2 pair) 73 HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 74 4Cx4 Sqmm armored and 3Cx2.5 Sqmm, armoured (FRLS) copper control cables (as per note given below)Note- 4Cx4 Sqmm armored and 3Cx2.5 Sqmm armoured (FRLS) copper control cables shall be used for integration of IEMs. The provision of providing the same is to be covered in respective entry of cables of the BoQ. 75 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90kN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for single Tarantula (string). 76 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for Twin Tarantula (string). 77 Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string). 78 Bolted type 33 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for twin Tarantula (string). 79 C- Wedge connectors matching with conductor size. 80 Copper lugs glands, PVC ferrules for control cabling. 81 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches 82 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150X25X2mm, 100X25X2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 83 AAC Tarantula Conductor(approx) 84 Spacers for Twin Tarantula conductor 85 7/3.15 Earthwire 86 U-bolt 20mm dia 87 Item for associated structure work‘Lattice type steel structure for 220kV GIS S/Stn.Sector-75A, Gurgaon. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/33kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.Main S/Stn. Tower and beamTower type AT-1 88 Tower type AB-1 89 Tower type CT-4 90 Tower type CT-5 91 Beam type DD-1 92 Equipment Supporting Structure) 220 kV NCT drg. No. HTD/ST-150 93 220 kV CVT drg. No. HTD/ST-147 94 220 kV surge arrestor drg.No.HTD/ST-93R 95 33 kV NCT Drg. No. HTD/ST-88 96 33KV L&E switch HTD/ST-110 97 33 kV Surge Arrestor Drg. No. HTD/ST-89R 98 220kV Cable Support Structure for 220kV XLPE Cable(To be designed by the bidder) 99 33kV Cable Support Structure for 33kV XLPE Cable(Drg. No. HTD/ST-89R to be used for Cable Support Structure drawing) 100 220kV D/C line from Sohna Road to 220KV GIS sector-75A, Gurugram :PLC terminals (No.) 101 PLC terminal with Prot.coupler (No.) 102 Wave trap 1250A 103 LTU (P/P) (Set.) 104 48V Lead Acid Tubular San container Battery& SMPS Battery Charger (300AH) 105 HFcable (kms) 106 220kV D/C Panchgaon (PGCIL) to 220KV GIS sector-75A, Gurugram:PLC terminals (No.) 107 PLC terminal with Prot.coupler (No.) 108 Wave trap 1250A 109 LTU (P/P) (Set.) 110 HFcable (kms) 111 Equipments for maintenancePortable circuit breaker operation analyzer. 112 Digital Micro-Ohm meter for contact resistance measurement Ranges (0-100 ohm)(0-1 milliohm)(0-10 milliohm). 113 Dew Point meter 114 Portable partial discharge monitoring system for GIS. 115 Digital Earth resistance meter. 116 5 kV Automated insulation resistance tester. 117 Earth stick with lead suitable for use in 220/33kV Switchyard 118 SF-6 Gas filling and evacuating plant 119 SF-6 Gas leak detector (Portable) 120 Tools for gas handling 121 LT DC Leakage detector from control cabinets and LT cables 122 Mandatory Spares for 220KV GISGeneralComplete GIS modules, along with enclosure, all active parts such as conductor, conductor joints, shields, end covers etc. for each type of➢ Bus Bar Sections (including Bus Bar Interconnection Modules)➢ Bus Ducts Sections (including Compensators/expansion joints/bellows)➢ Bends➢ SF6/Air Bushing.➢ Oil/SF6 Bushing➢ Cable Termination kit 123 SF6 gas Pressure Relief Device assembly of each type 124 SF6 Pressure gauge cum switch /Density monitors and pressure switch as applicable, of each type 125 Coupling device for pressure gauge cum switch for connecting Gas handling plant of each type 126 Rubber Gaskets, “O” Rings and Seals for SF6 gas for GIS enclosures of each type 127 Molecular filter for SF6 gas with filter bags (10 % of total weight) 128 Control Valves for SF6 gas of each type 129 SF6 gas (20 % of total gas quantity) 130 Pipe length (Copper or Steel as applicable) for SF6 Circuit of each type (if applicable) 131 Locking device to keep the Dis-connectors (Isolators) and Earthing/Fast Earthing switches in close or open position in case of removal of the driving Mechanism 132 UHF PD Sensors of each type along with BNC Connector 133 Support Insulators (gas through) of each type (complete with metal ring etc.) 134 Gas Barriers of each type (complete with metal ring etc.) 135 SF6 to air bushing of each type complete in all respect 136 SF6 CIRCUIT BREAKERComplete Circuit Breaker (Three Phase) with interrupter, main circuit, enclosure and Marshalling Box with operating mechanism to enable one to one replacement of applicable type of CB by spare. (if applicable) 137 Fixed, moving and arcing contacts including insulating nozzles of each type (for Main Chamber & PIR Chamber as applicable) 138 Trip coil assembly with resistor as applicable 139 Closing coil assembly with resistor as applicable 140 Relays, Power contactors, push buttons, timers & MCBs etc. of each type 141 Auxiliary switch assembly of each type 142 Operation Counter 143 Wind scope / Observing window of each type 144 For Hydraulic Operated Mechanism, if applicableHydraulic operating mechanism with drive motor of each type 145 Ferrules, joints and couplings of each type 146 Hydraulic filter of each type 147 Hose pipe of each type 148 N2 Accumulator of each type 149 Valves of each type 150 Pipe length (copper & steel) of each size & type 151 Pressure switches of each type 152 Pressure gauge with coupling device of each type 153 Hydraulic oil (20% of total Oil quantity) 154 Pressure Relief Device of each type 155 For Spring Operated Mechanism, if applicableComplete Spring Operating Mechanism including charging mechanism etc. of each type 156 Spring Charging Motor 157 For Hydraulic-Spring Operated Mechanism, if applicableComplete Hydraulic-Spring Operating Mechanism including charging mechanism etc. of each type 158 Spring Charging Motor 159 Pressure switches of each type 160 Pressure gauge with coupling device of each type 161 Disconnector Switches/Earthing SwitchesComplete set of 3-phase dis-connector of each type including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Isolator by spare 162 Complete set of 3-phase Maintenance Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare 163 Complete set of 3-phase Fast Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare (if applicable) 164 Copper contact fingers & corona shield for dis-connector male & female contact–for one complete (3-phase) dis-connector of each type 165 Copper contact fingers & corona shield for Maintenance Earthing switch male & female contacts, for one complete (3- phase) earthing switch of each type 166 Copper contact fingers & corona shield for Fast Earthing switch male & female contacts, for one complete (3-phase) earthing switch of each type (if applicable) 167 Open/Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps, Power contactors, resistors, fuses, MCBs & drive controlcards etc. one of each type for one complete MOM boxFor Disconnector 168 For Maintenance Earth switch 169 For Fast Earthing Switch (if applicable) 170 Limit switches and Aux. Switches for one complete MOM BoxFor Disconnector 171 For Maintenance earth switch 172 For Fast Earthing Switch (if applicable) 173 Drive Mechanism of each typei. For Disconnector 174 ii. For Maintenance earth switch 175 iii. For Fast Earthing Switch (if applicable) 176 Motor for Drive Mechanism of each typei. For Disconnector 177 ii. For Maintenance earth switch 178 iii. For Fast Earthing Switch (if applicable) 179 CURRENT TRANSFORMERComplete CT of each type and rating as supplied with enclosure and primary conductors to enable one to one replacement of all applicable type/rating of CT by spare 180 Voltage TransformerComplete PT of each type with enclosure to enable one to one replacement of all applicable type/rating of VT by spare (if applicable) 181 SURGE ARRESTORComplete Gas insulated Surge arrester of each type and ratings with enclosure and insulator (if applicable) 182 Surge counter/ monitor of each type (if applicable) 183 Local Control Cubicle (LCC)Aux. relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, MCB, Fuses, Timers, Terminal Blocks etc. of each type & rating 184 MANDATORY SPARES (33kV GIS)Line voltage transformer (3 nos.) 185 Bus voltage transformer (3 nos.) 186 Current transformers suitable for incomer panel (3 nos.) 187 Current transformers suitable for transformer panel (3 nos.) 188 Current transformers suitable for bus coupler panel (3 nos.) 189 Trip Coil 190 Closing Coil 191 CB Spring charging motor 192 Auxiliary switch (2 no. each type) 193 Disconnector motor for isolator 194 Disconnector motor for earth switch 195 Gas density switch 196 Bursting disc / pressure relief plate complete 197 Capacitive voltage indicator (6 nos.) 198 Civil portionEARTH WORK IN FILLING: Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 199 FOUNDATIONS :Design engineering, supply of labour,T&P,material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications including cost of excavation,concreting,cement,reinforcement steel,form work,grouting,holding down bolts,back filling etc. and other items not mentioned herein but required for the completion of work.GANTRY TOWERS AT-1 200 CT-4 201 CT-5 202 EQUIPMENT 220kV side220kV LA 203 220kV CVT 204 220kV NCT 205 33 kV side33kV LA 206 33kV NCT 207 CABLE SUPPORT STRUCTURE Design, Engineering, Supply of labour, material and Construction of cable support structure foundations including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. 220 KV Cable Support Structure 208 33kV Cable Support Structure 209 ROADSSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.6.0m wide road (Near main gate of substation) 210 5.0m wide road within substation 211 3.66m wide road within substation 212 CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.1x21.744MVAR 33kV capacitor bank 213 ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 214 TRANSFORMER FOUNDATIONDesign engineering, supply of labour, material and construction of foundations including T/F radiator foundations etc. complete in all respect including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned here in but required for the completion of work as per technical specifications. In case additional foundation is/ are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost toHVPNL.Such drawing(s)shall, however, be got approved from HVPNL.100MVA,220/33kV T/F foundationincluding associated foundations for radiator, NIFPES, fire fighting system etc. complete in all respect. 215 200KVA 33/0.4kv Station T/F 216 100kVA DG Set 217 OUTDOOR CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.D-type Trench 218 E-type Trench 219 F-type Trench 220 G-type Trench 221 H-type Trench 222 Road Culvert 223 Sump pit cum pump chamber 224 SITE SURFACINGProviding, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 225 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 226 RCC retaining wallSupply of labour, material and construction ofRCC retaining wall below DPC to retain the earth filling complete in all respect. Further, if L-shape retaining wall is required to be constructed as per site, the successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. Nothing extra shall be paid on this account. i. Difference between NGL & FGL from 2.5 to 3.5 mtr. 227 ii. Difference between NGL & FGL from 3.5 to 4.0 mtr. 228 Design engineering, supply of labour,material and construction of RCC T/L shaped retaining wall below DPC to retain the earthfilling complete in all respect and design /drawing shall be got checked/ vetted from any professsional institute as per contract before final approvalNothing extra shall be paid on this account. Iii. Difference between NGL & FGL above 4.0 mtr. 229 BOUNDARY WALL;Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 230 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect..6 ft. high U/C B/wall with barbed wire on angles at top. 231 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 232 4½ ft. high side wall with barbed wire on angles at top of wall. 233 MULTISTOREY 33kV GIS CUM CONTROL ROOM BUILDINGDesign including architectural and structural design/drawings, Engineering, supply of labour,T&P and material etc.for construction of multi storey GIS Hall comparising of ground and1st floor (to accumulate 33kV GIS & Control Room Building) including exterior weather proof paint, interior emulsion, all internal services like water supply and providing of 5000ltr. Capacity double layer Sintex/ Diplast PVCtank,Sewerage System, electrification including wiring, receptacle, modular switches, lighting, maximum 20W 4ft. long LED tube swith fittings minimum 1960 lumens, bulk headlig hts including fixtures. ceiling/ exhaust fans, plinth protection, closed drain (RCC Pipe)around building, Indoor trenches and provision for mechanical operated crane system adjacent to building, Soakage pit ,connection of sewerage system to Soakage pit/ sewerage system of local authority (as applicable), connection to main water supply system of local authority, bore (asapplicable)etc. and any other item not mentioned here in but required for completion of job as per specifications. Minimum size of the buildings has been provided in the GELO.Since the detailed engineering is in the scope of the successful bidder, no claim for increase in size of the building shall be admitted.The GIS Hall should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire.The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exitplans, etc complete in all order torun the system efficiently, wherever required as per latest IS Codal provision and in consultation with engineer incharge. 234 U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 235 PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 236 GIS Hall / BuildingDesign,Engineering including architectural & structural, supply of labour, material and construction of GIS building with ventilation system including crane hoisting system (EOT), equipment foundations as detailed in the bill of quantities under Annexure-1 of Section of bid/ contract documents , electrification including wiring, receptacle, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, bulk head LED lights including fixtures, ceiling/ exhaust fans, stair case etc.interior & exterior acrylic emulsion, paint, RCC paving /plinth protection starting from the building upto1.5 m clear distance for the full length width of the building, closed drain around the building (i.e RCC Pipe)etc. complete in al lrespect for GI Shall / building and any other item not mentioned here in but required for completion of job as per specifications. The building should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire. The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exit plans, etc complete in all order to run the system efficiently , wherever required as per latest IS Codal provision and in consultation with engineer incharge.220kV GIS Hall 237 DRAINAGE-CUM-RAIN HARVESTING SYSTEMSupply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 238 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.Drain Section-1 239 Drain Section-2 240 Drain Section-3 241 Road Crossing 242 Trench Crossing 243 Sump Pit Cum Pump Chamber 244 REMOVAL OF MALBARemoval/Disposal of malba irrespective of lead including loading & unloading etc. complete in all respect. Malba shall be disposed of to a suitable undisputed place outside the substation. as per Govt. norms. The successful bidder shall be responsible in case some dispute arise on account of disposal of malba/sludge at a disputed site. 245 CONSTRUCTION OF ANTI FIRE WALLConstruction of RCC anti fire wall of suitable height between T/F as per HVPNL drawing and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification. 246 RCCM-20 inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
38.
Home Affairs #9220029 Technical Bid
Renovation Of Toilet/Bathroom Of Fabrication At Ss Bn Itbp Force Saboli Sonipat Haryana , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. , Dismantling Of Flushing Cistern Of All Types (C.I./Pvc/Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead. , Disposal Of Building Rubbish / Malba /Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Cum , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Fixing Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/Window/Clerestory Windows & Desertory Other Frames/Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modulus Of Elasticity 900 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In- Charge. (M.S Hold Fast/Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). Note: For Wpc Solid Door/Window Frames, Minus 5Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made. Frame Size 45 X 70 Mm , Providing And Fixing Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Board One Side White Color And Other Side Of Board Laminted With Pvc Foil Of Minimum 14 Micron Thickness Of Approved Design Pasted With Hot Melt Adhesive For Cup Boards, Work Stations And Bathroom/Kitchen Cabinet Etc. Of Required Sizes Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/Cum And Screw Withdrawal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N/Mm2, Modulus Of Elasticity 850 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixing With Stainless Steel Piano Hinges/Soft Close Clip On Concealed Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. (Note: Stainless Steel Piano Hinges/Soft Close Clip On Concealed Hinges And Necessary S.S Screws Shal Be Paid Separately) 25 Mm Thick , Providing And Fixing 12Mm Thick Frameless Toughened Opaque Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer In Charge , Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In-Charge And Finished Smooth: Granite Stone Of Approved Shade Sqm , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Stone Slab Of Colour Black, Cherry/Ruby Red Area Of Slab Over 0.50 Sqm , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite Work , Extra For Providing Opening Of Required Size & Shape For Wash Basin/Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/ Granite/ Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I/C Malba All Complete As Per Directions Of Engineer-In- Charge. , Providing And Fixing 15 Mm Thick Densified Tegular Edged Eco Friendly Light Weight Calcium Silicate False Ceiling Tiles Of Approved Texture Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections (Galvanising @ 120 Grams Per Sqm Including Both Side) Consisting Of Main ‘T’ Runner Suitably Spaced At Joints To Get Required Length And Of Size 24X38 Mm Made From 0.33 Mm Thick (Minimum) Sheet, Spaced 1200 Mm Centre To Centre, And Cross “T” Of Size 24X28 Mm Made Out Of 0.33 Mm (Minimum) Sheet, 1200 Mm Long Spaced Between Main’T’ At 600 Mm Centre To Centre To Form A Grid Of 1200X600 Mm And Secondary Cross ‘T’ Of Length 600 Mm And Size 24 X28 Mm Made Of 0.33 Mm Thick (Minimum) Sheet To Be Inter Locked At Middle Of The 1200X 600 Mm Panel To From Grid Of Size 600X600 Mm, Resting On Periphery Walls /Partitions On A Perimeter Wall Angle Pre-Coated Steel Of Size(24X24x3000 Mm Made Of 0.40 Mm Thick (Minimum) Sheet With The Help Of Rawl Plugs At 450 Mm Centre To Centre With 25 Mm Long Dry Wall Screws @ 230 Mm Interval And Laying 15 Mm Thick Densified Edges Calicum Silicate Ceiling Tiles Of Approved Texture In The Grid, Including, Cutting/ Making Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc., Wherever Required. Main ‘T’ Runners To Be Suspended From Ceiling Using G.I. Slotted Cleats Of Size 25X35x1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm G.I. Adjustable Rods With Galvanised Steel Level Clips Of Size 85 X 30 X 0.8 Mm, Spaced At 1200 Mm Centre To Centre Along Main ‘T’, Bottom Exposed With 24 Mm Of All Tsections Shall Be Pre-Painted With Polyster Baked Paint, For All Heights, As Per Specifications, Drawings And As Directed By Engineer-In-Charge. , Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing : Rectangular Shape 1500X450 Mm , Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing :Oval Shape 450X350 Mm (Outer Dimensions) , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 20 Mm Nominal Dia Pipes , Disconnecting Damaged Overhead/Terrace Pvc Water Storage Tank Of Any Size From Water Supply Line And Removing From The Terrace Including Shifting At Ground Level As Per Direction Of Engineer-In-Charge. , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. Per , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :15 Mm Nominal Bore , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 18.21.2 45 Cm Length 15 Mm Nominal Bore , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required : Range Of Two Half Stall Urinals With 5 Litre P.V.C Automatic Flushing Cistern , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. , Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour Two Coats , Providing And Laying Vitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily. Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Of Tile 600 X 600 Mm , Providing And Fixing Ptmt Grating Of Approved Quality And Colour. 18.58.2 Rectangular Type With Openable Circular Lid 150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating , Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P/S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. Each , Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. (A) 15 Mm Nominal Dia , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15 Mm Nominal Bore Each , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore Each , Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Providing & Fixing At Site Under Counter Type Wash Basin On A Prepared Granite Counter: Jaquar Continental Cns-Wht-705 Under Counter Basin With Fixing Accessories, Size: 605X430x200 Mm, Shape: Oval Or Of Similar Make (Roca/Kohler/Hindware) With Equivalent Appearance, Market Rate, Performance, Accessories, Shape, Size, Etc. With Wall Flange And Making Good The Complete Work As Per The Approval Of Engineer-In-Charge , Providing & Fixing At Site Heavy Duty Quarter Turn 2 Way Bib Cock Jaquar Opal Prime Opp-15041Pm Or Of Similar Make (Roca/Kohler/Hindware) With Equivalent Appearance, Market Rate And Performance, Accessories, Shape, Size, Etc. With Wall Flange And Making Good The Complete Work As Per The Approval Of Engineer-In-Charge , Providing & Fixing At Site Cp Shop Dish Holder Bath Accessories (Acn-1131N) (Jaquar/Kohler/Parryware) Make As Per The Site Requirement Etc Complete , Providing & Fixing At Site Cp Towel Rail (600Mm Long ) Jaquar (Acn-1111Sm) Or Of Similar Make (Roca/Kohler/Hindware) With Equivalent Appearance, Market Rate And Performance, Shape, Size, Etc. And Making Good The Complete Work As Per The Approval Of Engineer-In-Charge Make As Per The Site Requirement Etc Complete , Providing & Fixing At Site Cp Health Faucet Jaquar (Ald-577) (Jaquar/Kohler/Parryware) Or Of Equivalent Make (Roca/Kohler/Hindware) With Same Appearance, Market Rate And Performance, Shape, Size, Etc. And Making Good The Complete Work As Per The Approval Of Engineer-In-Charge Make As Per The Site Requirement Etc Complete , Providing And Installation Of Pvc Exhaust Fan Havells Ventil Air Hush 150 Mm White (Fhvvehuwht06) Or Equivalent Of Philips/Bajaj/Orient Or Equivalent Make In Rate, Appearance And Performance With Shutter Complete 300 Mm In The Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. As Approved By Engineer In Charge , Sitc Of Havells Octane Led 2X2 Panel 36 W Led 4000 K Light Or Equivalent Make (Bajaj/Philips/Orient) In Market Rate, Appearance And Performance In False Ceiling With Complete Fitting , Providing And Fixing Havells Austra Mirror Light 20 W Led 4000 K Complete Fitting Or Similar Item Of Equivalent Make (Bajaj/Jaquar/Philips/Orient) With Equivalent Performance, Size, Shape, Accessories And Market Rate As Per The Approval Of The Engineer-In Charge , Sitc Of Jaquar 15 L Storage Water Geyser (Erica Digital 15 Ltr Storage Water Heater) With Multi Function Safety Valve, Double Safety Thermostat, Earth Leakage Circuit Breaker, Energy Saving High Density Puf Insulation, Automatic Shut-Off And 2000 Wattage Of Similar Make (Roca/Kohler/Hindware) Equivalent In Market Rate, Performance, Same Accessories, Size. Shape And Appearance With Complete Fitting As Approved By The Engineer-In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
39.
Power #9209642 Technical Bid
Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2023-24-- 1 Supplyof : 2 11 KV link Set (Station type) Suitable for 800 Amp current capacity. (IS: 9920 (Part-I to IV)) with 8 mm Copper Knife 3 11 KV link Set (Line type) Heavy duty. Suitable for 800 Amp current capacity. (IS: 9920 (Part-I to IV)) with 8 mm Copper Knife 4 11 KV Air break switch with pipe & handle complete (3 phase, 600 Amp) (IS: 9920 (Part-I to IV)) 5 11 KV Drop Out Fuse Set 3 Phase 400A (IS:9385 (Part-I to III) as amended upto date) 6 Gapless Surge Arrestor, 9 KV, 10 KV, LA with (polymer/porcelain) housing, Stn. Type(IS: 3070 Part-3) 7 11 KV Pin insulator with pins 12 KN.(IS:731 and IS:3188) 8 LT Shackle Insulators with Mukki Clamps (16 KN) of Standard Make with Nuts and Bolts 9 Galvanised Nuts and Bolts of sizes. 6”,7”,8”,9”,11”,12”x1/2” dia half thread. 10 G.I wire 8 SWG. 11 Guy wire 7/14 SWG. 12 Guy rods with turn buckle 5’ long complete 13 11 KV tension disc/suspension Disc(IS:731 and IS:3188) 14 Fabricated GI channel, X-arms of sizes (75x40x6) mm (50x50x6)mm and (100x50x6) mm. 15 Fabricated GI Angle, (50x50x6mm) 16 Al. Solderless clamps suitable for transformer1000 KVAas per relevant IS 17 Al. Solderless clamps suitable for transformer630 KVA as per relevant IS 18 Al. Solderless clamps suitable for transformer400/500 KVA as per relevant IS 19 Al. Solderless clamps suitable for transformer250 KVA as per relevant IS 20 Al. Solderless clamps suitable for transformer100 KVA as per relevant IS 21 Al. Solderless clamps suitable for transformer63 KVA as per relevant IS 22 Aluminium Thimbles 1 MVA as per relevant IS 23 Aluminium Thimbles 630 mm2 as per relevant IS 24 Aluminium Thimbles 500 mm2 as per relevant IS 25 Aluminium Thimbles 400 mm2 as per relevant IS 26 Aluminium Thimbles 300 mm2 as per relevant IS 27 Aluminium Thimbles 240 mm2 as per relevant IS 28 Aluminium Thimbles 185 mm2 as per relevant IS 29 Aluminium Thimbles 120 mm2 as per relevant IS 30 Aluminium Thimbles 95 mm2 as per relevant IS 31 Aluminium Thimbles 70 mm2 as per relevant IS 32 Aluminium Thimbles 35 mm2 as per relevant IS 33 Aluminium Thimbles 25 mm2 as per relevant IS 34 Aluminium Thimbles 16 mm2 as per relevant IS 35 35 mm sq, 11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster 36 50 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster 37 70 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster 38 95 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster 39 120 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster 40 16 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 41 25 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 42 50 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 43 185 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 44 240 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 45 300 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 46 400 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 47 630 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster 48 25 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 49 35 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 50 50 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster 51 185 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 52 240 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 53 300 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster 54 400 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 55 630 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster 56 Galvanized earthing strips 50mm x3mm. 57 Bobin Insulators clamps/cliffs. 58 Back Clamp Collars/Pole Collars G.I. 59 Galvanized ABC Cable Hooks/I Hooks 60 Aluminum paint (Asian/Nerolac/Berger) make. 61 Red oxide paint (Asian/Nerolac/Berger) make. 62 11 KV Heat Shrinkable Outdoor Cable Termination Kit 63 11 KV Heat Shrinkable Outdoor Cable Jointing Kit 64 11 Mtr. (IS 2713 540 SP 56)Steel Tubular Poles 65 9 Mtr. (IS 2713 540 SP 33)Steel Tubular Poles 66 8 Mtr. (IS 2713 540 SP 15)Steel Tubular Poles 67 30mm2 ACSR Conductor IS: 398(Part-II) ammended upto date 68 50mm2 ACSR Conductor IS: 398(Part-II) ammended upto date 69 100mm2 ACSR Conductor IS: 398(Part-II) ammended upto date 70 630 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 71 400 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 72 200 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 73 160 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 74 100 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 75 63 Amp 3 Pole Thermal Magnetic MCCBs having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) 76 Rubber shoes sole insulation IS 4770 ammended upto date and working potential of 11 kV 77 20 feet long , 11 kV Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , manufactured from Fibre Reinforced Plastic material , having HV test of 110 kV, push button locking sytem, crocodile grounding clamp ,rubber clading to hold, Die cast Alu. Earthing instrument for 30mm diameter (with 4 sq mm copper cable 8 mtrs;top section diameter > 25 mm and bottom section diameter >45 mm)with earthing spike of Standard Make 78 Battery operated 11-33 kV Voltage Detector (CPRI Tested) complete kit including HV detector probe, 20 feet FRP insulation stick, carrying bag. The detector should haveaudio as well as visual anunciation, sensing distance of 1 meter for 11kV and 3 meters for 33kV. Bright high intensity Red LEDs for visual annunciation even in unfavourable daylight conditions and a buzzer to produce loud beep audible even in noisy backgrounds 79 Natural Latex 11kV Rubber Gloves(Type-2IS 4770; ISI Mark)with test voltage >=17000 V and Working Voltage of 11000 with maximum leakage current at tets voltage of 14mA (rms) [ ISI Mark and IS Conformation on Each glove] 80 White Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] 81 Yellow Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] 82 Safety Belt with static and dynamic loading completely as per IS 3521 [ ISI Mark and IS Conformation on Each Belt] 83 UK SIZE 6 and below Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] 84 UK SIZE 7 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] 85 UK SIZE 8 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] 86 UK SIZE 9 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] 87 UK SIZE 10 and above Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] 88 Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 to 36)-1 Set, Wrench 12-1 No, Measuring tape 25 Mtr-1 No, Hexa Frame with Blade-1 No, Tester-1 No, L Key-1 Set and Combination Spanner (6 to 36)-1 setBOSCH/DEWALT/TAPARIA 89 Clamp Meter, Conforms to IEC 61010, CAT II 600V safety rated, 600A AC current measurement, AC/DC voltage, resistance, continuity & data hold function, 2 years manufacturer warranty [FLUKE/DIGI SENSE/ MOTWANE/EXTECH] 90 18 feet Fiber Link Rod 91 18 feet Bamboo Link Rod 92 Manually Operated Megger (500/1000 Mega Oms) 93 LT Fuse Set (630 Amp) 11 KV Polymer Type 94 GI Chemical earthing 2 mtr with Chemical Bag 95 Search Light (LED) 1 km Range 96 Bamboo Ladder 18 Long 97 Aluminium folding ladder 20 ft Long 98 Wooden Ladder A Class Budloo [Finished Length of 17 (3 by 1.5) ; Finished Step (2 by 1.5 ) ; Bottom Width 18; Step to step distance 13]alongwith MS Straps on both side of each step 99 16 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type(IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent 100 25 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type(IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
Jammu And Kashmir View Result →
40.
Power #8882533 Technical Bid
Centralized Biennual Rate Contract For M / S Chhabi Make Dc Battery Chargers Spares Centralized Biennual Rate Contract For M / S Chhabi Make Dc Batterycharger Spares , Handle With Knob 0412221153 , Transducers , Ac Contactor 415V, 300A Type: Ml-12 , Voltage Relay Module C , General:Heat Sink , Power Isolator-220Vdc, 160A, 3Vp5301-4Hv74 , Rg3-S:Surge Suppressor, Varistor , On Delay Electronic Timer. , Supergen320:Glass Fuse , On / Off Delay Timer , 470K Ohm Carbon Film Resistor 2Watt , Resistance 4K Ohm 12 Watt Wire Wound , Wire Wound Resistance 33 Ohm, 25W , Electrolyte Capacitor 3300Mfd, 50V Dc , Filter Condensor, 2200Mfd / 450V , Inductr:Choke:0.0-10.0 Mh:Cu , Inductr:Choke:1560A 0.067 Micro Henry:Cu , Shunt - 1000A / 75Mv , Thyrstr:Skkh162-18E:156A, 1800V:Semikron , Thyrstr:Skkt 330A:800Ma, 60Kv ( P ) :Semikron , Diode: Ar302-2 - 760A, 1000 Piv , Diode:Skkd162:1000Piv, 162A , Power Contctr: 3P 415Vac, 415Vac, 550A, , Aux. Contractor Cv 220Vac, 2No+2Nc, Tc , Aux Contactor For Dc Coil Volt 24V Dc , Thermal Overload Relay:A 9.0-14A:Gen , Thermal Overload Relay:A 87.5-130A:3Ua , Hrc Fuse Link36amp Ee , Hrc Fuse Link:63A:& Size:D:Gen , Hrc Fuse Link 75 A Gsb75ee , Hrc Fuse Link:100A:& Gs:Ee , Hrc Fuse Link:400A:& Size:Ee , Hrc Fuse Link:500A:& Size:Gen , Volt Meter Selector Switch , Sfu:Heavy Duty-Tp:315A:415V , Heavy Duty Switch Fuse Unit ( Tp ) , Sfu:Heavy Duty-Tp:250 A:660V , Sfu:Heavy Duty-Tpn:32A:660V , S / W Discontr:4Pole:2500A:24V , Control Terminal Socket Assembly 9 Ways , Space Heater 240V Ac, 250 Watts , Controltransformer 415 / 110V 500Va , 10 Kva, 1-Phase Trf 415 / 230 Vac , Isolation Transfmr: 3Ph 30Kva 415 / 415V, D , Control Xymr:1Ph, 500Va 456V / 240V , Control Xymr:20Kva, 0-415V / 0-24V , Control Xymr:10Kva, 0-415 / 0-50V , Xmr 3Ph D / Wound:85Kva, 456 / 48V Star / Star , Xmr 3Ph D / Wound:50.75Kva456 / 46V Star / Str , Xr 3Ph D / Wound:50.75Kva456 / 46V Star / Dlta , 3 Phase Charger Card ( Id No: 41-98-19120 , 200A D.C . Shunt , Transformer ( 187 Bd Card ) Tv25, 60Kvaups, Db , Choke 3 Ph I / P Class H 0.22Mh-400 A , 630A, 3 Pole On / Off, Sfu Ckt Ref:S101 , Pcb-Dc U / O Volt & Relay Ckt., 5 Kva Ups. , Batt. Earth Fault Card Pt:Pcb 304Db-1 / 2 , Scr Diode Module For Rectifier ( Vtd ) , Transient Voltage Surge Suppressorttl , Annunciator Ckt: 8F S96 C8f Ce, For Bt.Ch , Rectifier Diode-For Battery Chrgr;Chhabi , Dc Load Under / Over Voltage Relay:044R3ce , Fuse Failure Detector Ckt.: 47Ar2 Ce , Diode-Forward-Capsule-800A-400V , Glass-Fuse-1 A With Holder-Rail Mount , 2Pole 2Way On / Off Cam Auto / Manual Switch , Surge Protection Device Val Ms320 / 8 / 3+0 , Blocker Diode W / O Heat Sink , Filter Choke , Dc Output Swtch , Rs 485 Controller Card, Pt:Daa13a17dlcdae , Bc:Chhabi:3-Ph-Dw-Transformer , Bc:Chhabi:Transformer-Acor Ckt , Bc:Chhabi:Aux-Transformer ( Lcd -Dp ) , Bc:Chhabi:Filter Choke-400A , Bc:Chhabi:Shunt , Bc:Chhabi:Contactor-3P , Bc:Chhabi:Thermal O / L Relay+M-Kit , Bc:Chhabi:Aux-Contactor-Ap , Bc:Chhabi:Cam Switch-2P , Bc:Chhabi:C / O Relay- Acor , Bc:Chhabi:Solid State Timer-55U , Surge Suppresor Cp-Cc 220V / 400A ( Mov Type , Fuse Fail Card, 48V Charger; Chhabi , Annunciator Card, 48V, 144Sqmm Led Disp , Hv Pf Psr Card, 48V , Batt.Chargr.Transformer-24V-825A; Chhabi , Bc:Chhabi:24V-825A:Controller , Controller Card Cpc1 , Aux.Transformer: 3Va, 480V / 0-11V , Interphase Transformer - 24V, 1250A , Intr / Ph.Transfmr: 24V, 780A, 3.2Kva;Chhabi , Current Limit Indication Card:40-4-0780; , Rectifier Back Plane: #Pcb Pcba5318r00; , Dc-Dc Converter For Batt.Chrgr#69-00076 , Dc Voltage Transducer , Voltage Transducer, I / P:0-132Vac, Dual O / P , Current Transducer 0-5Amp / 4-20Ma Dual Op , Hvac Power Supply Input Module Tg Tsi , Fmr Mounting Clamp , Microprocessor Based Alarm Annunciator C , Alarm Annunciator Model Mbas 9400 , Window Facia ( Unengraved ) 24 Volt Dc , Thcoup L250mmty K Mounting Clamp 2In , U / O Voltage Relays , Heater Thermal Cutout Pt.0234712 , Hv Phase Fail Card;53 / R Chhabi Charger , Dc / Dc Converter 11-33V / 5V ( 0-6Amp ) , Dc / Dc Converter ( 200W ) :Scm-Con ( Cbs2002424 , Thyristor 280A, 1500V, , Rectifier Transformer , Fuse Link-16A , Carbon Film Resistors Tol1%1 / 2W 4.7K , 120Kh Carbon Film Resistor 1 Watt , Rstr Metl Flm:470 Ohm:Unspecified:1 / 4W , Electrolytic Capacitor 400Vdc, 2500Mfd , Cap Polstr Fxd:1000V Dc:470 Pf , Inductr:Choke:73A, 0.101Mh:Cu , Thyrstr / Scr: Tt Module-57A, 1600V , Thyrstr / Scr:Tt Modul:70A1000piv:Semicron , Thyrstr:Skkt162:160A / 1000Piv , Diode: Skkd46, 1600V, 46A , Diode:1600Piv, 800A , Relay With Display: 170-220Vdc, 220V Ac , Aux Contactor , 63A Hrc Fuse Tis63 , Fuse Link , Fuse Link 25A , Semi Conductor Fuse , Type Gs1000 , 150A , Kaycee Voltmeter Selector Switch , Rot Cam Switch 12A, Kaycee 1T260 / Gb , Kaycee Make Switch 3T36b0 , Rotary Cam Swtch, 2Way, 440V Ac, 10A, 1S160 , Swt Fuse Is13947 Hvy Tpn 100A 440V , On Delaytimer With 2 C.O Delay &1 Inst. , Inter Phase Transformer:400A , Control Xymr:5Va, 0-415V / 21-0-21V , Power Supply Unit I / P 240Vac , 100A D.C Shunt , Axial Cooling Fan 160M / Hour 220V Ac , Earth Fault Detection Pcb , Capacitor 0.22Mfd / 1400V For Keltron Ups , Resistor 50 Ohm, 50W For Sci-60 Kva Ups , Diode 40A, 1200Piv Stud Type , Scr - 50A, 600V Piv , 24V Smps: 12C Latn Fc0a Bc40a Ac; Chhabi , Pcb-Pulse Card-6P , Chhabi:110V-10A, Bleedr Resistance 5K / 50W , Semiconductor Fuse Link, Gsb20 , Hv&Pf / Psr Circuit With Transformer , Ac Voltm Meter Selector Switch , Dc Voltmtr , Over Load Relay , Bc:Chhabi:Transformer-240V , Bc:Chhabi:Filter Choke-60A , Bc:Chhabi:Lcd Display , Bc:Chhabi:Dc Ammeter+Ext-Shunt , Bc:Chhabi:Rotary Switch-2P , Bc:Chhabi:Cam Switch-1P / 2W-Lockable , Bc:Chhabi:Led Wi-Module , Bc:Chhabi:Aux Transformer , Filter Choke, 100A , Earth Leakage Card , 48V, 1-7Ma , Scr Without Heat Sink-120A, 1000Piv , Filter Choke 800A , Cpc Card, 3 Ph 220V , Aux.Transformer: 48V / 18-0-18V , Annunciator Card - 24 V , Ac-Dc To Dc Covtr.Card: Conade179501aac0 , Daa Module: 16Di / 12Do / 4Ai, Lcd2l; Chhabi , 24V / 12V / 1.5A Dc-Dc Convrtr: 303Ce;Chhabi , Mains Fail Card For Batt.Chrgr#69-00251 , Rs485 Com Port Card; For Battery Charger , Dc Ammeter:150-0-150A, Mc;Cl:1.5, 96X96mm , Dc Voltmeter: 0-500Kv, 96X96sqmm , Ac Voltmeter: 0-500V, Mi, Cl:1.5, 96X96mm2 , Voltag Transdcr:I / P:0-500V:O / P:4-20Ma ( D , Voltage Transducer- 4 To 20 Ma Dc- 0 To , Transducer I / P 0-400Vdc O / P 4-20Ma , Diode Gp Axial , 1 A, 1000V, 1N4007 Diode , Aux Contactor , Microprocessor Based Alarm Annunciator , Dc / Dc Convertor ( 220 V Procon Make , Annun.Window Facia: 16Point, 90-270Vac / Dc , Annunciation , Capacitor;10000Mfd / 150Vdc;36Feeder , Resistor Wirewound#0100700301;36 Feede , Dc-Dc Converter 220V / 24V Typ-Gw220 / 24 / 25 , Hv Module: A10b Htg30, For Sem- Vega-3; , Relay Interface Unit , Dc Converter Card-U1, 24Vdc, 10A, Plc, Dm , Cast Aluminium Heat Sink, For Dh350 Diode , Filter Capacitor , Fuse Link - 100Ma , Rotary Cam Swt Ope 2Wa 250Vac 16Asrp113a , Trip Relay Size-4S Aux Voltage-48 V Dc , Timr:24V-240V Ac / Dc:0-30 Sec:Rely On / Off , Scr Controller.Card: Cpc-1, Pcb No-207 , Dc Ammeter W / O Shunt , Bc:Chhabi:Sb-Diode+Heat Sink , Bc:Chhabi:Aux Contactor-F / B Selection , Pulse Card: Pcb No.-234Br1ce; Chhabi , Bc:Chhabi:Volt Transducer , Hv Pf Psr Card, 25Va 415V, 456V / ( 18-0-18V ) , Earth Leakage Relay Card: 34R2; Chhabi , Current Limt Detector: 00105R1 Ce;Chhabi , Dc Ammeter:0-75A, Cl:1.0, Size:96X96sqmm , Dc Voltmeter: 0-50V, Cl:1.0, Size:96X96mm , Ac To Dc Converter Card, 200-240Vac / 24Vdc , Toggle Switch ( Is:3452 ) :220-250V, 10A , Thyrstr / Scr:Skkt57b:570A, 1600V , 315Amp Hrc Fuse Make - Csc Typecdfl2 , Fuse-Hrc-Link500 Amp, Din Type , 32Amp 415V Fuse Base , Toggle Sw;2Pos;10A;250Vac;Kayceekt1021by , Auxiliary Relayinterlock , Timer: 240Vac, 0.1S-10Hr.On-Dl / Off-Dl;Bch , Earth Fault Relay , 220V Dc, Cag12af38a , Resistor-Wire Wound, 3.3Kohm, 50W, + / -5% , Scr Controller Card For Battery Charger , Dc Ammeter:600-0-600A / 75Mv-1.5-90D , Bc:Chhabi:Bleeder Resistor , Bc:Chhabi:E / F Ckt +Imd , Bc:Chhabi:Transducer Ac-T / P Volt-M , Rectifier Module: R24-2200; Make: Chhabi , Annunciation Module#Atrm0w12b0211;Chhabi , Dc U&O / V Cardu / V-199V, O / V-260V , Silicon Blocker Diode - 1120A / 1000 Piv , Pulse Card: 53R1; Make: Chhabi , Scr Control Module: Avr / Acr Comp Id M19; , Dc Ammeter:0-600A, Cl:1.5, Size:96X96mm , Dc Voltmeter: 0-50V, Size: 96X96sqmm , Ac Voltmeter: 0-500V, Cl:1.5 , Siemens Surge Suppressor , Shunt Resistance 75A / 75Mv For Dc Ammeter , Dual Output Dc Current Transducer , M01.C Glass Fuses 100Ma , Annunciator , Dc To Dc Converter: 24V To 12V / 1.5A , Cooling Fan -6, 230Vac , Aux. Transformer , Surge Suppression Capacitor , Glass Fuse 1A-30Mm , Aux. Relay Module , Surge & Spike Suppressor: 230 Vac, 50Hz , Wire Wound Potentiometer: 10K Ohm, , Paper Capacitor 0.47Mfd 1000V , Metalizedpvccapacitors 0.47 Mfd 250 V.Dc , Rot / Cam / Switch 16A, 250Vdc 4Pole 2Way , C&S Dc Contactor 2No+2Nc, 10A, 220Vdc , Scr- Slow- 170A-1200 V -Stud , Snubber Network Pcb Card: R-C; Chloride , Current-Limit Detector Circuit; Chhabi , Bc:Chhabi:Hv Pf / Ps-R Circuit , Bc:Chhabi:Aux Relay Annunciation , Scr Rating 445A / 1000 Piv , Scr 580A, 1000Piv , Earth Leakage Card, 1-7Ma , Pulse Driver Card - 24 V , Resister Wire Wound, 2K 25W , Ac / Dc Converter For 24 Volts , Rstr Carbn:U / S:1 / 4W:4.7Kohms , Rstr Carbn:U / S:1 / 4W:120Kohms , Rotary Cam, Switch, 12A 240V Ac , Kaycee R Cam Switch 2Way, On Off, , Bc:Chhabi:Bleeder Resistance Rb 1A / B , Bc:Chhabi:Cam Switch-2P / 2W , Bc:Chhabi:Ffd Circuit-Ssst , Bc:Chhabi:Aux Relay-O / L Annunciation , Bc:Chhabi:Aux Relay-Boost-M Annunciation , Bc:Chhabi:Transducer Dc-Current-M , Aux Cont 4A / 415V Ac ( Ac Mains Fail ) , Fuse Fail Detector, 220V , Fuse Fail Detector Relay For Ac I / P , 3Ph Scr Full Contrlr.Card: 052R1 Ce;Chhb , Resistor 470K 0.5W 5Pc Ref 15-=16702 , Dc / Dc Converter For 24 Volts , Diode:Skkd101:1000Piv, 101A , 3Pole 2 Way On / Off Boost / Float Switch , Scr Controller Card Pt:Coa02001052r1ceo , Bc:Chhabi:Fuse Link , Dc-Dc Converter , Wire Wound Resister , 0.5-1.5Mm2.Fuse Type Terminal Block 2Way , Wire Wound Resistor 3.3K Ohm , Wire Wound Resistor 500E , 3Th30 Aux Contactor Ac Coil 230V 2No+2Nc , 6Amp Hrc Fuse Make -Csc Typeaaooh , Auto / Manual Selector Switch, 2T26b-12 Amp , 6 Fan ( Byp Stsw&Inv .Stsw ) 230V, 60Kvaups , Capacitor Electrolytic-10000Mfd-50Vdc , Ffd Circuit Card Pt:Ff3f200147ar2ace , Dc Uv &Ov Relay Card, Pt:Dcuov001044r3ace , Bc:Chhabi:Cam Switch-1P / 2W , Fuse Fail Detector Relay , Indicating Lamp ( Complete ) , Resistor 4 Ohms / 63000 ( Deltapi ) , Indicating Lamp Green , Cooling Fan: Rec22060 Rb24 Mw; Rexnord , Semiconductor Fuses Ee Gsa-100 , Add On Block 2No+2Nc , Lt Swtch Gr:Pwr Cntor:2No+2Nc , Thyristor Block , Hv Pf Psr Card Pt:Hvpfp001053r10ce , Bc:Chhabi:Dropping-Resistance , Annunciation+Atr Pb-For Bat.Chrgr;Chhabi , Cooling Fan For Charger 27W / 230 Vac, 9 , 33K Ohm Carbon Film Resistor 2 Watt , Tis Type Hrc Fuse63 Amp 80Ka, , Sp On / Off Switch 12A , Bc:Chhabi:400A-Sc-Fuse , Bc:Chhabi:Potentio Meter 10K / 3W , Dc Output Fuse Ffd Card: 47 A-R2; Chhabi , Bc:Chhabi:Dc U&O Relay Module Pcb , Bc:Chhabi:Monitoring & Annunciation Ckt , Surge Prot-Device For Bat.Chrgr; Chhabi , Cpc Controller Card: Pcb-234Ar3; Chhabi , Semiconductor Fuse, 25A, Bussman , Semiconductor Fuse, 200A, Bussman , Fuse 56A:Semi Cond Typ 56Et 690Vac Busmn , Semiconductor Fuse Link 400A, 690 Volts , Hrc Fuse Tia Type 32Amp , Oen Relay, 24Vdc, 3C / O Contct, 2R-3-24-750 , Pla Make Relay, 3C / O Mpc, 240A, 240V Ac , Bc:Chhabi:Scr+Ss-Nw+Heat Sink , Resistor 220 Ohm / 300W , Thyrstr / Scr:Skt551:551A / 1000Piv:U / Spec. , Semiconductor Fuse:20 A, 500 V Ac:Nsh / Ge , Bc:Chhabi:Dropping-Resistance-4K / 25W , Capacitor 2200Mfd 450V Dc , Indication Led L24vac / Dc;22.5Mm Dia , S / Condr Fuse:80A 500Vac:Ge;Type:Nsh , Series External Resistance For Cc / Tcser , Semi Conductor Fuse , Type Gs1000 , 400A , Cap Fltr:200V:5000Mfd , Silicon Control Rectifier , Hrc Fuse Link 2A Ns Ee , Hrc Fuse Link:6 A :Ns :Ee , Resistor 200 Ohm, 100W For Sci-60 Kva , Filter Capacitor , Cooling Fan - Size: 8, Voltage: 230Vac , Led Lamp Assembly 220V Dc, Red Colour , 230Vac Led Indicating Lamp Module Red , 230Vac Led Indicating Lamp Module Blue , 230Vac Led Indicating Lamp Module Green , 230Vac Led Indicating Lamp Module Yellow , 1700 Ah Float / Boost Charger Exhaust Fan , Bc:Chhabi:24V-925A:Dc Relay -24V , Capacitors Electrolytic 400V Dc4700mfd , Glass Cartridge Fuse - 500 A Instrument , Wire Wound Resistor , Semiconductor Fuse Gs1000 / 100 , Filter Condenser 4700Mfd / 100V , Bc:Chhabi:24V-925A:Ac Relay-2 C / O , Current Transdcr: 0-1000 / 4-20Ma; 220Vdc , Electrolytic Capacitor:2200 Micro Farad, , Glass Fuse 500Ma 20Mm , 150Kohm Carbon Film Resistr 2Watt , Bc:Chhabi:Filter Condenser , Filter Capacitor , Bc:Chhabi:Capacitor-Pfi
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Chhattisgarh View Result →
41.
Power #8832853 Technical Bid
Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2021-22 .-2 11 Kv Link Set ( Post Type ) Heavy Duty. Suitable For 400-630 Amp Current Capacity. ( Is: 9920 ( Part-I To Iv ) ) 3 11 Kv Air Break Switch With Pipe & Handle Complete ( 3 Phase, 600 Amp ) ( Is: 9920 ( Part-I To Iv ) ) 4 11 Kv Drop Out Fuse Set 3 Phase 400A ( Is:9385 ( Part-I To Iii ) As Amended Upto Date ) 5 Gapless Surge Arrestor, 9 Kv, 10 Kv, La With ( Polymer / Porcelain ) Housing, Stn. Type ( Is: 3070 Part-3 ) 6 11 Kv Pin Insulator With Pins 12 Kn. ( Is:731 And Is:3188 ) 7 Lt Shackle Insulators With Mukki Clamps ( 16 Kn ) Of Standard Make 8 Galvanised Nuts And Bolts Of Sizes. 6”, 7”, 8”, 9”, 11”, 12”X1 / 2” Dia Half Thread. 9 G.I Wire 8 Swg. 10 Guy Wire 7 / 14 Swg. 11 Guy Rods With Turn Buckle 5’ Long Complete 12 11 Kv Tension Disc / Suspension Disc ( Is:731 And Is:3188 ) 13 Fabricated Gi Channel, X-Arms Of Sizes ( 75X40x6 ) Mm ( 50X50x6 ) Mm And ( 100X50x6 ) Mm. 14 Fabricated Gi Angle, ( 50X50x6mm ) 15 Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is 16 Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is 17 Al. Solderless Clamps Suitable For Transformer400 / 500 Kva As Per Relevant Is 18 Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is 19 Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is 20 Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is 21 Aluminium Thimbles 630 Mm2 As Per Relevant Is 22 Aluminium Thimbles 500 Mm2 As Per Relevant Is 23 Aluminium Thimbles 400 Mm2 As Per Relevant Is 24 Aluminium Thimbles 300 Mm2 As Per Relevant Is 25 Aluminium Thimbles 240 Mm2 As Per Relevant Is 26 Aluminium Thimbles 185 Mm2 As Per Relevant Is 27 Aluminium Thimbles 120 Mm2 As Per Relevant Is 28 Aluminium Thimbles 95 Mm2 As Per Relevant Is 29 Aluminium Thimbles 70 Mm2 As Per Relevant Is 30 Aluminium Thimbles 35 Mm2 As Per Relevant Is 31 Aluminium Thimbles 25 Mm2 As Per Relevant Is 32 Aluminium Thimbles 16 Mm2 As Per Relevant Is 33 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per ( Is 7098 Part 2 Ammneded Upto Date ) Polycab / Havells / Paramount / Gloster 34 50 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per ( Is 7098 Part 2 Ammneded Upto Date ) Polycab / Havells / Paramount / Gloster 35 70 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per ( Is 7098 Part 2 Ammneded Upto Date ) Polycab / Havells / Paramount / Gloster 36 95 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per ( Is 7098 Part 2 Ammneded Upto Date ) Polycab / Havells / Paramount / Gloster 37 120 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per ( Is 7098 Part 2 Ammneded Upto Date ) Polycab / Havells / Paramount / Gloster 38 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 39 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 40 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 41 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 42 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 43 300 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 44 400 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 45 630 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 46 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 47 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 48 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 49 185 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 50 240 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 51 300 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 52 400 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 53 630 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type ( Is 7098 Ammended Upto Date ) Polycab / Havells / Paramount / Gloster 54 Galvanized Earthing Strips 50Mm X3mm. 55 Bobin Insulators Clamps / Cliffs. 56 Back Clamp Collars / Pole Collars G.I. 57 Galvanized Abc Cable Hooks 58 Aluminum Paint ( Asian / Nerolac / Berger ) Make. 59 Red Oxide Paint ( Asian / Nerolac / Berger ) Make. 60 11 Kv Heat Shrinkable Outdoor Cable Termination Kit 61 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit 62 11 Mtr. ( Is 2713 540 Sp 56 ) Steel Tubular Poles 63 9 Mtr. ( Is 2713 540 Sp 33 ) Steel Tubular Poles 64 8 Mtr. ( Is 2713 540 Sp 15 ) Steel Tubular Poles 65 30Mm2 Acsr Conductor Is: 398 ( Part-Ii ) Ammended Upto Date 66 50Mm2 Acsr Conductor Is: 398 ( Part-Ii ) Ammended Upto Date 67 100Mm2 Acsr Conductor Is: 398 ( Part-Ii ) Ammended Upto Date 68 630 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 69 400 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 70 200 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 71 160 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 72 100 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 73 40 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal ( 0.8 In-1.0 In ) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Ue ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. N ( Make: Abb / Eaton / Havells / Legrand / L&T / Schneider / Siemens ) 74 Rubber Gloves Passed As Per Standard Is 4770 Ammended Upto Date And Working Potential Of 11 Kv 75 Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv 76 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods ) , Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter ( With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter > 25 Mm And Bottom Section Diameter >45 Mm ) With Earthing Spike Of Standard Make 77 Battery Operated 11-33 Kv Voltage Detector ( Cpri Tested ) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds 78 Natural Latex 11Kv Rubber Gloves ( Type-2 Is 4770; Isi Mark ) With Test Voltage >=17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma ( Rms ) [ Isi Mark And Is Conformation On Each Glove ] 79 White Color Industrial Safety Helmets ( Is 2925 ) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet ] 80 Yellow Color Industrial Safety Helmets ( Is 2925 ) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet ] 81 Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt ] 82 Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe ] 83 Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe ] 84 Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe ] 85 Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe ] 86 Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe ] 87 12 Piece Tool Kit ( 1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench ( Adjustib And 1-Piece Measuring Tape ) Bosch / Dewalt / Taparia 88 Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac / Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [ Fluke / Digi Sense / Motwane / Extech ] 89 18 Feet Fiber Link Rod 90 18 Feet Bamboo Link Rod 91 Wooden Ladder A Class Budloo [ Finished Length Of 17 ( 3 By 1.5 ) ; Finished Step ( 2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13 ] Alongwith Ms Straps On Both Side Of Each Step 92 16 Mm² Cable ( 2C ) From Lt Line To Meter , 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type ( Is 1554 Part 1 Ammended Upto Date ) Polycab / Havells / Paramount / Or Equivalent 93 25 Mm² Cable ( 2C ) From Lt Line To Meter , 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type ( Is 1554 Part 1 Ammended Upto Date ) Polycab / Havells / Paramount / Or Equivalent
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
42.
Defence #8724029 Technical Bid
Tender For Short Refit Work Package 50T Tug Sahas-1 Short Refit Work Package:- General Service. Scaffolding ( With Material ) To Be Arranged For Survey Purpose For A Total Number Of 80 Days. Quote For Services. 2 Fire Sentries With Necessary Fire Fighting Equipment, To Fight Fire Are To Be Provisioned. Quote For Services. 3 Cleaning Of All Tanks And Provide Gas Free Certificate. The Vendor Is To Be Provide All Consumables Required For Cleaning. Repair Plating, Structures And Fittings Of Water Ballast Tank And Fresh Water Tank As Per Survey Report. Damaged Area To Be Blasted Up To Bare Metal And Recoated As Per Existing Paint Scheme. Quote For Services. 4 Degutting & Regutting – Removal And Refiting Of Panels ( Approx 30 Sqm ) And Pipes. Quote For Both Services And Material. 5 Carry Out Non-Destructive Testing For Bollards, Fairleads And Hull Structure Including Stiffening Members In The Vicinity. ( A ) Survey To Be Done In Presence Of Nsry / Fab Survey Teams And Survey Reports To Be Provided. ( B ) Requirement To Undertake Renewal Of Structures, Based On Survey Report, To Be Included In Sow. Quote For Services And Material. 6 Testing Of Wt Compartment. All Tanks, Cofferdams And Sea Tubes Which Have Been Repaired By Build-Up / Renewal Or Have Been Subjected To Hot Work Through Welding Of Pad Piece / Foundation On Any Of Their Boundaries, Are To Be Air Pressure Tested. The Pressure Applied Should Never Exceed That Which Corresponds To A Pressure Of 0.2 Kh / Cm2 ( 02 Mtr Of Water Or 0.2 Bars Or 2 1 / 2 Ibf / In2 ) . Ballast Tank - Qty 03 , Fuel Tank – Qty 05, Fw Tank – Qty 02, Misc Tank - 04. Clearance Of Areas, Subject To Apt Will Be Accorded By Nsry / Fab Survey Team. Quote For Services . 7 Mast And Riggings. ( A ) Examine Mast Structure, Whip Aerial Platforms And The Surrounding Structure On Deck, Eye Plates, Load Carrying Members, For Signs Of Corrosion. Examine Bolted, Riveted And Intermittent Welded Structure Connections For Signs Of Fracture. Portable And Semi Portable Fittings To Be Removed For Closer Examination Of Structure Underneath. Defect To Be Rectified And Paint To Be Restored. All Marks Of Corrosion And Rust Are To Be Removed. Requirement Of Paint And Other Consumables To Be Catered For By The Vendor. Quote For Services And Material. 8 ( A ) Test All Standing & Running Riggings Fitted On Mast Structure Along With Associated Fittings. Renew All Wire Ropes And Associated Fittings As Necessary. ( B ) Carry Out Load Testing Of All Deck Eye Plates ( Qty 14 ) , Bottle Screws ( Qty 14 ) And Provide Load Test Certificate. Damaged Eye Plates And Bottle Screws Are To Be Renewed By The Vendor, Together With Relevant Load Test Certificates / Guarantee / Warrantee. Quote For Services. 9 Steel Renewal. Any Requirement To Include Transportation Of Steel And Preparation Of The Plates, Including Shaping And Positioning At Location Has To Be Catered For By The Vendor.Quote For Services. 10 Funnel. Examine, Clean And Restore Paint Of Eye Plates And Surroundings Structure, Funnel Structure ( Internal And External ) . Portable Or Semi-Portable Fittings That Obscure Structure Are To Be Removed And To Be Recoated Before The Fittings Are Replaced. Requirement To Ensure That Damaged Areas Requiring Steel Renewal Together With Paint Renewal Will Have To Be Undertaken By The Vendor. Quote For Services And Material. 11 Accommodation And Office. Repair / Renewal Of Wooden Furniture And Wooden Fittings Including Table, Chairs And Wooden Cupboards In Compartment And Accommodation Spaces. Quote For Services And Material. 12 Repair / Renewal Of Bunks, Mess Lockers And Their Securing Arrangements. Lockers And Securing Arrangements That Are Beyond Repairs, Are To Be Replaced With Suitable Alternatives. Quote For Services And Material. 13 Repair / Renewal Of Defective Deck Covering And Renewal Of Deck Plates Underneath As Per Survey Report Of Yard. Deck Coverings Being Renewed, Should Be Those That Have Been Approved By Navy. Quote For Services And Material. 14 Anchor, Chain Cable And Cable Locker. Lay Out All Cables, Survey Cable And Shackles, Break, Clean And Grease All Joining Shackles, Strip And Grease Slip In Cable Locker. Re-Arrange Cable Length To Ensure Equality Of Wear. Re-Mark Cable Length. Examine Hull Associated Fittings. Examine All Spare Chain Cable And Fittings, Clean And Coat With Boiled Linseed Oil. Dismantle Anchor. Clean And Grease Trunion Pin And Housing. Grease To Be Used:- Lg-280 Patt.No. 0474 / 910-0502. Hydrojet Lasting Of The Anchor Chain Cable To Be Carried Out. The Machined Surfaces Of The Joints Of Lugless Joining Shackles Are To Be Examined For Corrosion And All Such Shackles Are To Be Stripped, Greased And Re-Assembled. The Anchor, Chain And Cable Locker To Be Restored To Factory Fit Functionality. Quote For Services And Material. 15 Machinery Spaces. Clean All Bilges Using Approved Chemical Method. Clean Out All Limber Holes And Drain Holes. Examine Structures Not Covered By Lagging, Paying Particular Attention To Position Where Water Is Likely To Accumulate, Junctions Of Longitudinal With Side Platings And Machinery Bearers With Bottom Plating, Horizontal Surfaces Such As Tank Tops, Horizontal Stiffeners And Structure Obscured By Cable Plating. Portable Fittings That Obscure Structure Are To Be Removed For Examination Of Structure Behind. Carry Out Surface Preparation In Accordance With No 53 / 16 And Recoat The Damage Paint. Disposal Of Sludge ( Approx 50 Tons ) To Be Catered For By The Vendor. Consumables For Cleaning Also To Be Catered For By Vendor. Paint Scheme Restoration In All Areas As Per Existing Navy Standards. Quote For Services And Material. 16 Check The Condition Of The Vibration Mounts. Clean And Apply Necol Lacquer. Spm Readings Of Equipment Will Need To Be Certified By Nsry / Engg / Ele Teams. Vibration Damping If Not Adequate, Will Need To Be Replaced By The Vendor After Grouping Of Mounts. Certification I.R.O The Same May Be Provided. Quote For Services And Material. 17 Renew Damaged / Perished Lagging At Various Places Using Pin Method. Renew Paint Scheme Of Affected Areas Before Renewal Of Lagging. All Consumables Are To Be Catered For By The Vendor. Quote For Services And Material. 18 Capstan ( Oem - Geeta Engg ) . All Structural And Functional Defects Pertaining To Motor And Capstan Assembly To Be Rectified By The Vendor By Repairs / Renewal. Requisite Fluids To Be Positioned For Lubrication. Motor Spm Values And Power Ratings For Safe Operation To Be Proved During Trials. Offer For Trials To Ss Post Completion. 19 Anchor Windlass ( Oem - Geeta Engg ) . All Structural And Functional Defects Pertaining To Motor And Capstan Assembly To Be Rectified By The Vendor By Repairs / Renewal. Requisite Fluids To Be Positioned For Lubrication. Motor Spm Values And Power Ratings For Safe Operation. Offer For Trials To Ss Post Completion. Quote For Services And Material / Spares. 20 Renewal Of Mushroom Head With Spindle And Valves. Renewal To Also Include Safety Nets / Fasteners As Per Requirement / Joints And Gaskets. Quote For Services And Material. 21 Sewage Treatment Plant ( Oem – M / S Eva Coy N40ce ) . ( A ) Functioning Of Level Switches Of V-1 Tank. Operate All The Valves Which Have Not Been Changed From A Set Position To Prevent Jamming. Carryout De-Sludging Of V-2 Tank By Back-Flushing Line. Clean The Seawater ‘Y’ Type Strainer At The Inlet To ‘Bookcell’. Check Macerator Pump Oil Level By Removing The Pipe Plug Located On Top Of The Pump Casing. Oil To Be Renewed. Vendor To Cater For Disposal Of 5 Ton Sludge Associated With Stp System. Overhauling Of System And Auxiliaries To Be Undertaken. Qc Coverage For Overhauling To Be Provided By Nsry / Qc Team. Ber Valves / Pipes / Joints And Fittings To Be Renewed. All Fluid Replenishment To Be Undertaken As Required. ( B ) Clean Air Supply Filter / Regulator Element In Solvent By Removing The Screws That Secure The Air Chamber To The Filter Body. Drain, Inspect & Clean The ‘Bookcell’. Remove Large Deposits Of Hard Material With Diluted Hydrochloric Acid. Post Completion Of Routines, Operate System And Inspect For Leaks And Proper Cell Amperage. ( C ) Inspect The Tightness Of Belt And Check Leakage From Gland Of Discharge Pump. Repack The Gland ( If Required ) . Quote For Services And Material / Spares. 22 Macerator Pump. Carry Out The Following :- ( A ) Check To Ensure There Are No Leakages From The Main Seals. Renew Drive End Bearing And Seals If Required. ( B ) Check And Ensure That The Impeller Rotates Freely With No Vibration. ( C ) Inspect And Tighten Nuts And Bolts As Necessary. ( D ) Check Overload Units Operating Correctly. ( E ) Check All Valves For Correct Operation. ( F ) Remove Drain Plugs Provided At Each End Of The Bracket Of The Electric Motor And Allow Any Accumulated Moisture To Drain Away And Replace Plugs. Note. Replacement Of The Pump Assembly To Be Undertaken By The Vendor, If The Discharge Rate Does Not Meet Oem Designed Standards. Quote For Services And Material / Spares. 23 Clean And Lubricate All Plug Cock Valves. Lubricate Valves In Fully Opened Or Fully Closed Position Only. Quote For Services And Material. 24 ( A ) Undertake Effluent Test From Nabl Accredited Lab And Check Compliance To Marpol Norms. ( B ) Carry Out In-Situ Calibration Of Fixed H2s Sensor. Certificate Of Calibration To Be Obtained From The Oem. Date Of Calibration And Next Due Date Should Be Clearly Indicated On The Certificate. ( C ) Sewage Pollution Prevention Certificate Valid For Duration Of Five Years From A State Authorised Accredited Agencies As Specified In Mepc 115 ( 51 ) And 227 ( 64 ) For The Ship Adopted On 01 Apr 04 As Per Regulation 5 Of Revised Annex Iv Of Marpol 73 / 78 ( Ncd 3930, Issue 3, Sep 16 Is Relevant ) . Quote For Services. 25 Towing Hook With Quick Release Mechanism ( Oem - M / S Nautiluis Eng & Construction Company ) . Carry Out Load Testing Of Towing Hook And Undertake Repairs. Job Involves Serviceability Of Release Line And Repairs. Replacement Of The Towing Hook With Quick Release Mechanism To Be Undertaken If Existing Unit Exceeds Service Life / Not Functioning As Per Design. Quote For Services And Material / Spares. 26 Grease Filters Inside Exhaust Trunking In Galleys To Be Cleaned And Preserved. Renew If Defective. Quote For Services And Material. 27 Doors - Water Tight And Non-Wt Doors. Check Clips, Hinges For Looseness And Wedge Pieces For Signs Of Wear. Examine Leather Washers, Toridal Sealing Rings And Rubber Sealing. Renew Worn Out Parts And Carry Out Chalk Test Of All Wt Doors. Quote For Services And Material. 28 Scuttles & Windows. Check Hinge Fitting, Toughened Glass And Glass Rails For Looseness And Sign Of Wear / Damage. Renew Worn Out Parts As Necessary. Windows – Qty 32, Scuttles – Qty 18. Quote For Services And Material. 29 Hatch And Manholes. Survey Hatch And Manholes Covers. Remove And Clean Hatch And Tumbler Hinges & Pins. Apply Grease. Deteriorated Hatches And Manhole Covers To Be Fabricated. Securing Fasteners Wherever Damaged To Be Renewed With Stainless Steel Fasteners As Per Recommendations Of Survey Team. Carry Out Chalk Test Of All Wt Hatches And Renew Worn Out Parts As Necessary. Quote For Services And Material. 30 Ladders. Repair The Ladders With Associated Footsteps. Structural Defects In The Ladder Assembly Other Than Steps Also To Be Catered.Quote For Services And Material. 31 Single Arm Boat Davit ( Oem - Hemant Engg ) . Overhauling Of Boat Davit Along With Motor Assembly. Offer For Trials To Ss Post Completion. Structural And Functional Defects Of The Single Arm Boat Davit To Be Rectified By Repairs / Renewal Of Components. Quote For Services And Material. 32 Survey Wire Rope, Spare Gear And Other Associated Lifting Gears. Renew As Necessary. Renewal Of Wire Ropes To Be Undertaken As Per Existing Naval Guidelines. Quote For Services And Material. 33 Carry Out Load Testing With Davit Fully Rigged Up. After Completion Of Load Test, Examine The Complete Davit Structure And Associated Lifting Gears For Flaws, Distortion, Defects Etc. Flaws Must Be Examined And Repairs To Be Undertaken, Followed By Retesting. Quote For Services And Material. 34 Water Accumulation Observed On Both Side Of Foxle. Scupper System To Be Re-Positioned For Clearance Of Water Accumulation. Painting In Areas Affected By Hot-Work / Steel Renewal To Be Restored By Vendor. Quote For Services And Material. 35 02 Bullwark Doors Damaged. Hinges Corroded. To Be Renewed. Mat – Ms. Quote For Services And Material. 36 Bullwark Damaged / Deformed At Various Location. To Be Repaired / Renewed. Mat – Ms. Quote For Services And Material. 37 ( A ) Rubber Fenders On Both Side Of Tug Found Damaged / Perished. Fenders To Be Renewed. Length- 50 Mtr. ( B ) Securing Fasteners For Fenders Found Perished / Corroded. To Be Manufactured As Per Sample And Fitted Back. Note. Deformation Of Base Structure / Strengthening Members On To Which The Fenders Are Secured Are To Be Surveyed And Deformations, If Any To Be Rectified By Hotwork / Steel Renewal. Quote For Services And Material. 38 Wooden Fenders Damaged In Port And Stbd Side. To Be Renewed. Job Involves Re-Fitment Of Fenders On Ship Side. Quote For Services And Material. 39 Natural Air Vent Of All Compartments Wire Mesh Broken, Air Vent Corroded, Flaps Rubber Beading Perished. Hinges And Butterfly Nuts Corroded. To Be Renewed. Quote For Services And Material. 40 Sounding Points Of Fresh Water Tank Threads Worn Out. To Be Repaired / Renewed. Quote For Services And Material. 41 Securing Bracket Of Fire Hose Box Corroded At Multiple Locations. To Be Renewed. Quote For Services And Material. 42 Lifebuoy With Self Igniting Light And Smoke Signal ( Mob Marker ) Quick Release Type To Be Renew On Bridge Deck. Quote For Service And Mat. 43 Fibre Sheet For Weather Deck Canopy Damaged. To Be Renewed. Quote For Services And Material. 44 Platform For Head Bollard Corroded / Damaged. To Be Repaired / Renewed. Quote For Services And Material. 45 Platform For Quarterdeck Bollard Corroded / Damaged. To Be Repaired / Renewed. Mat - Wood. Quote For Services And Material. 46 ( A ) Fisherman Plate Along With Securing Pin Corroded. To Be Manufactured As Per Existing Plate And Pin ( Qty 02 ) . ( B ) Bottle Screw For Anchor Chain Stopper Corroded. To Be Renewed ( Qty 02 ) . Quote For Services And Material. 47 Life Raft Stowing Brackets ( Qty 02 ) Along With Sliding Ladder Damaged / Corroded. To Be Repaired / Renewed And Operational. Job Involves Renewal Of Life Raft Securing Straps. Quote For Services And Material. 48 Serviceability Checks Of Life-Rafts ( Qty 02 ) And Hru ( Qty 02 ) By Nabl Accredited Agency. Webbing Of Life-Raft To Be Renewed, If Damaged Beyond Repair. Quote For Services And Material. 49 Covers ( Both Compressor Safety Mesh Cover And Control Panel Cover ) For 02 Ac Compressor Units On Upper Deck Damaged / Broken. To Be Manufactured. Mat - Al Plate. Quote For Services And Material. 50 15 Cm Ms Strip On Upper Deck Wt Doors Damaged / Corroded. To Be Manufactured And Welded In-Situ. Quote For Services And Material. 51 Internal Super Structure - Repair Works To Be Under Taken On Internal Hull Structure Including Bulkhead And Fittings As Per Survey Report. Painting To Be Under Taken Post Repairs. Quote For Services And Material. 52 Refrigerator On-Board Defective. To Be Repaired / Renewed. Quote For Services And Material. 53 01 Weather Deck Locker Damaged. To Be Repaired / Renewed. Quote For Services And Material. 54 Executive Chairs Fitted At Wheel House Observed To Be Damaged. To Be Renewed. Quote For Services And Material. 55 Engine Room Blower Wire Mesh And Securing Ms Strips Broken / Corroded. To Be Renewed. Quote For Services And Material. 56 Sunmica And Wooden Beading Of Dining Hall Table Broken / Damaged. To Be Repaired / Renewed. Quote For Services And Material. 57 Canvas Covers Of Following Deck Equipment Torn / Perished. To Be Renewed. Windlass, And Control Stand, Rescue Boat, Search Light ( Qty 02 ) , Magnetic Compass, Capstan And Capstan Control, Boat Davit Motor, Me And Da Exhaust And Intake. Quote For Services And Material. 58 Anchor Cleaning Sea Water Line Chocked / Damaged. To Be Repaired / Renewed. Quote For Services And Material. 59 Mob Stand ( Qty 04 ) And Bracket Damaged. To Be Renewed. Quote For Services And Material. 60 ( A ) Foundation Of Port And Stbd Search Light Found Deteriorated. Repair To Be Carried Out. ( B ) Rotating Mechanism Of Port And Stbd Search Lights To Be Renewed. Quote For Services And Material. 61 Hull Survey. Clean All Tank Tops, Bilges Of Machinery Spaces And Other Accessible Internal Surfaces Of Underwater Hull. Damaged Area To Be Blasted And Paint To Be Restored As Per Existing Paint Scheme. Quote For Services And Material. 62 Underwater Platings. ( A ) Remove Marine Fouling From The Hull Using Hydro Jet With Maximum Pressure Not Exceeding 3000 Psi. ( B ) Areas Where Breakdown Of Abrasive Anticorrosive Paints Observed, To Be Blasted And Recoated With Full Paint Scheme. ( C ) Paint Scheme On Full Underwater Hull And Boot Top Including Wind And Water Areas I.E. Area Up To 500Mm Above Boot Top Area Is To Be Restored. ( D ) Application Of One Coat Of A / F Paint On Underwater Hull And Boot Top Area To Be Carried Out Post Adequate Surface Preparation. Quote For Services And Material. 63 Draught Marks. Draught Marks To Be Painted With Paint Scheme As Under Water Area And Top Coat To Be Painted With White Paint. ( A ) Fwd ( B ) Midship & ( C ) Aft. Renew Defective Draught Marks. Quote For Services And Material. 64 Above Water Area ( Ship Side, Superstructure And Fittings, Davit, Windlass, Capstan ) . ( A ) Clean The Hull Using Hydro Jet With Maximum Pressure Not Exceeding 3000 Psi. Damaged Area To Be Blasted Up To Bare Metal. ( B ) Carry Out Painting Of Above Water Area With High Performance ( Hpp ) Advanced Hybrid Coating System For Above Water Area ( Ship Side & Superstructure ) As Per Paint Scheme Mentioned Below:- ( I ) 02 Coats Of Primer To Achieve 80 Microns Dft. ( Ii ) 02 Coats Of Ral 7040 Colour Specification To Achieve 80 Microns Thickness. ( Iii ) Total Dft - 320 Microns. Note. Navy Approved Paint To Be Used. Requirement Of Paint, Other Consumables And Staging To Be Catered For By The Vendor. Quote For Services And Material. 65 Life Saving Appliances. ( A ) Stretcher ( Qty 01 ) For Life Saving Damaged. To Be Renewed. Size - Standard. ( B ) First Aid Box Locker Damaged At Various Location. To Be Renew And Fitted On Specific Locations. ( Oem - M / S Godrej & Boyce Mfg Co Ltd. ) . ( C ) Life Jacket With Light And Whistle Damaged ( Qty 19 ) . To Be Renewed As Per ( Lsa Code Msc 207 ( 81 ) ) . Testing Of Life Jackets To Be Carried Out. Quote For Service And Material. 66 Water Filter Cum Purifier Defective / Damaged In Crew Dining Hall. To Be Renewed. Job Involves Fitment. Quote For Services And Material. 67 Following Defective Wc And Bathroom Accessories To Be Renewed. ( A ) Shower - 05, ( B ) Water Tap - 06, ( C ) Urinal With Full Fittings And Accessories - 03, ( D ) Commode With Full Fittings And Accessories - 04, ( E ) Two Way Basin / Sink - 04. Note. Defective Valves And Reducers, To Be Renewed. Quote For Services And Material. 68 Carryout Chemical Cleaning Of All Trunkings. Renew Perished / Damaged Trunkings On Upper Deck And Mess. Paint To Be Restored Post Repairs As Per Existing Paint Scheme ( Qty - 80 Sqm ) . Quote For Services And Material. 69 Hose Box Damaged / Broken At Various Location ( Qty 07 ) . Securing Brackets Corroded. To Be Manufactured And Refitted In-Situ. Mat - Grp. Quote For Services And Material. 70 Weather Deck & Bridge Top Deck Corroded / Undulation At Various Location. Hydro Blasting To Be Under Taken Prior Survey. Defects To Be Rectified As Per Survey Report Of Yard. ( A ) Aarea To Be Painted With High Performance Non- Skid Coating System For Weather Decks ( Hpp ) Paint Scheme As Mentioned Below Post Defect Rectification And Plate Renewal As Per Survey Report. ( B ) 07 Years Guarantee Paint Scheme Of Da Grey Colour To Be Used. ( C ) Navy Approved Paint Scheme To Be Used. ( D ) Paint Scheme Of Weather Deck And Platforms:- ( I ) 01 Coat Primer Coat - Dft 50 Microns. ( Ii ) 01Coat Anti Corrosive Intermediate Coat - Dft 200 Microns. ( Iii ) 01 Coat Non-Skid Top Coat - Dft - 800 Micron. ( Iv ) Total Dft - 1050 Microns. Note. Paint To Be Restored As Per Paint Scheme Post Repair And Inspection. Paint To Be Provided By Refitting Firm.Quote For Services And Material. 71 Combing Around Wheel House Deck Corroded / Damaged. To Be Repaired / Renewed In Situ. Mat - Ms Quote For Services And Material. 72 Panelling Damaged / Corroded At Various Location. To Be Renewed. Mat - Ss. Job Involves Removal Of Existing Panels And Fitment. Quote For Services And Material. 73 02 Mooring Rope Reel, 01 Towing Rope Reel And 01 Cable Reel Broken. To Be Manufactured And Replaced In-Situ. Job Involves Welding And Cutting Assistance And Fitment. Quote For Services And Material. 74 ( A ) Ships Name Box Along With Lighting Arrangement Defective. To Be Renewed. Mat - Ms ( Qty – 02 ) . ( B ) Ships Name Board On Port And Stbd Side To Be Renewed. Mat - Wood ( Qty – 02 ) . Quote For Services And Material. 75 Microtech Damaged At Various Location. Removal Of Old Microtech To Be Undertaken. Surface Preparation To Be Carried Out For Hull Survey. Defects To Be Rectified As Per Survey Report Of Yard. Microtech To Be Renewed Post Application Of Primer On Deck. Quote For Services And Material. 76 Dado Area In Wet Compartment Corroded / Damaged. To Be Repaired / Renewed. Job Involves Removing Of Gutting Degutting Of Panels. Quote For Services And Material. 77 Heavy Duty Tyre Fenders Of Barge Found Damaged. Renewal Of Fenders To Be Carried Out. Hot Work Required For Removal And Fitment Of Tyre Fenders To Be Carried Out ( Qty -20 ) With 60 Eye Pads And 16 Mm Galvanised Chain Along With D Shackle. Undertake Apt Of Hot Work Tanks If Any. New Heavy Duty Tyre Fenders To Be Provided By Firm. Quote For Services And Material. 78 Wire Mesh And Ball Valve Of Air Vent On Upper Decks Be Replaced If Required. Structural Defects On Air Vents To Be Repaired. Quote For Services And Material. 79 Strip, Clean And Overhaul Domestic Fresh Water System Valves, Stop Cock ( Qty 05 ) , Basin Beep Cock ( Pillar ) ( Qty 04 ) , Sink Beep Cock ( Pillar ) ( Qty 01 ) . Mat - Brass ( Chrome Plated ) . Quote For Services And Material. 80 ( A ) Ventilation Flaps Of All Compartments, Wire Mesh Broken, Air Vent Corroded, Flaps Rubber Beading Perished, Hinges And Butterfly Nuts Corroded, Ventilation Lowers Damaged / Corroded. To Be Renewed ( Qty 16 ) . ( B ) Punka Lowers Damaged At Various Trunkings. To Be Renewed And Fitted. Material To Be Provided By Firm ( Qty - 05 ) . Quote For Services And Material. 81 Cathodic Protection Sacrificial Anodes-Renew Sacrificial Anodes Fitted To Under Water Hull, Voith Blade, Rope Guard, Shaft Tunnel, Stern Tubes, Inlet And Outlets, Seachest, Biges And Cofferdams. 82 Enginering Dl: ( Port And Stbd Main Engine, Wartsilla, Model : 8L-26 2000H ) :- Carry Out 2000 Hourly Routine Of Main Engine :- ( A ) Check Engine Oil Leakage, Fixation Of Piping, Cables And Wring Rectify Leakage And Loose Cable Connection. N ( B ) Check Engine On Bolt Connection, Repair Loose Bolts. N ( C ) Check Engine Drain Points Of Charge Air Receiver And Possible Water. N ( D ) Check Oil Level, Charge Oil If Required. N ( E ) Check Foundation Bolt And Chocks. Repair If Required. N ( F ) Renew Fuel And Lub Oil Filter. N ( G ) Clean Centrifugal Filer. N ( H ) Drain Starting Air Vessels And Air Treatment Units. N ( J ) Servicebility Checks Of Ht And Lt Cooling Water. N ( K ) Clean Air Compressor By Water Injection. N ( L ) Inspect And Clean Air Filter To The Turbo Charger. N ( M ) Check Function Of By-Pass And Waste Gate Assembly. N ( N ) Lubricate Fuel Control Mechanism Linkage. N ( P ) Check If Alarm And Safety System Is On With Running Engine, Rectify If Not Working. N ( Q ) Check Function Of Measuring Devices, Calibrate If Not Working Properly. N ( R ) Check Function Of Oil Mist Detector, Calibrate If Not Working Properly. N ( S ) Check Operation Of Turning Gear And Start Inter Lock Device, Repair / Calibrate If Malfunctioning. N ( T ) Check / Adjust Valve Clearance. N ( U ) Main Engine Ups Control Panel Door Damaged. To Be Renewed. N ( V ) Main Engine Fresh Water Cerculating Pump No.1 Breaker Tripping Frequently. Defect To Be Rectified. N ( W ) Both Me Lcp Display Malfunctioning. To Be Renewed. N ( X ) Turbocharger Outlet Temperature Sensor Faulty, To Be Replaced ( Port Main Engine ) N ( Y ) Both Main Engine Starting Air Line Water Trap Valves To Be Overhauled N ( Z ) Both Pre-Heater To Be Dismantled, Mechanically Cleaned And Boxed Back. System To Be Pressure Tested And Proved For Operation Post Fitment Of Pre-Heater. Test Pr- 3 Kg / Cm2. N ( Aa ) Both Pre- Hetaer Circulating Pump Alongwith Motor To Be Overhauled N ( Ab ) Main Engine Expansion Tanks ( Qty - 03 ) To Be Cleaned And Paint To Be Restored As Per Paint Scheme. Respective Sight Glass ( Qty-01 ) To Be Renewed. N ( Ac ) Stbd Main Engine Rpm Not Exceeding Beyond 260 At Idle As Against 600 Rpm, Defect To Be Rectified ( M / S Wartsila Engine ) N ( Ad ) Fuel Injectors Of Both Main Engines To Be Calibrated ( M / S Wartsila Engine ) N ( Ae ) Governor Calibration Of Stbd Main Engine To Be Undertaken ( M / S Europe Actuatore ) N ( Af ) Excessive Lub Oil Consumption On Both Main Engine. Dr To Be Undertaken N N 83 ( Port And Stbd Da, M / S Cummins India Ltd, 3000H ) :- Carry Out 3000 Hourly Routine :- N ( A ) Remove Injectors. Clean, Inspect, Repair & Calibrate With New Spares. N ( B ) Remove Heat Exchanger. Clean & Pressure Test. N ( C ) Remove Turbocharger. Clean, Inspect & Repair With New Repair N Kit ( Check Turbocharger End Play And Radial Clearance ) Ntighten Nut & Cap Screw Of Air Inlet And Exhaust System. Ncheck Vibration Damper Visuallyrepair If Defective. N ( D ) Replace Belts And Accessories. N ( E ) Check All Cut-Out & Safety Controls. Renwe If Defective. N ( F ) Flush Cooling System With Restore Plus, Run Engine To Bring It To Operating Temperature. Stop The Engine Reflush Cooling System With Portable Water 2-3 Times. Refill Cooling System With Coolant. Run The Engine For Three To Five Minutes. N ( G ) Post Completion Of Routines, Start The Engine And Check All Gauges, Replace If Required, Check For Oil / Water Leakage, Exhaust Leakage, Stop The Engine And Recheck Engine Oil Level, Top Up If Required. After Necessary Inspection Restart The Engine. Run At Idle Speed For 15 Minutes; Carry Out Safety Device Checks. Undertake Full Load Trials On Completion. Post Complition Of Routine Carry Out Sdc Checks And Load Trails, Calibrate / Renw Defective Safety Divices. N ( H ) Da Control Panel Door Damaged. To Be Renewed. 84 Port And Stbd Voith Turbo Schneider, Model - 21 R 5 / 150-2:- Carry Out Docking Routines And 5000 Hourly Routines :- ( A ) Check The Screw Joint Renew If Dfective. N ( B ) Check For The Leakage From Blade Shaft Sealing, If There Any Keajage Rectify It. N ( C ) Check For The Leakage From Main Seal, Change Seal If Defective. N ( D ) Check Main Gear Toothing For Any Damage, Rpair It If Damaged. N ( E ) Check The Input Gear Rpair It If Damaged. N ( F ) Check For The Leakage From Mounting Gear. If There Is Any Leakage Rectify It. N ( H ) Check For Leakage From The Propeller Well. If There Is Any Keajage Rectified It. N ( J ) Check For Correct Fuctionnig Of Rotor Space Ventilation Repaired It If Defective. N ( K ) Renew Corrosin Protection. Note. Quote For Services And Material / Spares. N 85 Fuel And Lub Oil Centrifuge Make-Alfa Laval Pa 605:- Carry Out Five Yearly Routines On Fuel And Lub Oil Centrifuge :- ( A ) Clean And Inspect Inlet And Outlet Pipe Threads, Paring Disc, Housings And Frame Hood. Renewed Damaged / Defective Parts. N ( B ) Clean And Inspect Separator Bowl, Top Disc, Bowl Discs, Distributor, Nozzles In Bowl Body, Sliding Bowl Bottom, Discharge Mechanism, Threads On Bowl Hood And Bowl Body, Bowl Spindle Cone And Bowl Body Nave, Renewed Damaged / Defective Parts. N ( C ) Clean And Inspect Oil Mist Fan, Oil Pump, Water Tank, Bowl Spindle, Ball Bearing Housing, Indentations And Radial Bobble Of Bowl Spindle, Renewed Damaged / Defective Parts. N ( D ) Clean Oil Sump, Change Oil And Oil Filling Device. N ( E ) Clean And Inspect Friction Coupling, Renewed If Defective. N ( F ) Replace Electric Motor Bearing. N 86 Ows Make-Suyash, Modle-Sd0.5:- Carry Out Five Yearly Routines :- ( A ) Replace Coalesce. N ( B ) Replace Adsorber Elements. N ( C ) Replace Stuffing Box Packing. N ( D ) Check Stator And Rotor, Replace Worn Out Component. N ( E ) Replace Zinc Anode. N ( F ) Check Oil Level Of Pump Gear, Fill Up If Required. N ( G ) Open The Inspection Port Of The Oil Separator Housing, The Oil Separator Housing And The Adsorber Housing. Replace Worn Out Parts. N ( H ) Remove The Sludge And Clean Container. N ( I ) Check Seal And Piston Valves, Replace Damaged Seal And Components. N ( J ) Replace Sensor Electrode. N ( K ) Checks The Function Of Heater, If Defective Replace It. N ( L ) Shore Suuply Connection Box Damaged. Box To Be Renewed To Ensure Water Tight Integrity. N 87 Reciprocating Air Compressors Make Elgi ( Model Hp 10 300 ) :- Carry Out 1000 Houlry Routines Of Air Compressor :- ( A ) Change Oil. N ( B ) Observed Noise And Vibration. N ( C ) Check Fasteners, Renwed If Dfective. N ( D ) Check For Air Leakage, Rectify If There Any Air Leakage. N ( E ) Adjust Pressure Setting As Per Manual. N ( F ) Change Inlet Air Filter. N ( G ) Clean Breather Valve. N ( H ) Inspect Valves, Renewed If Defective. N ( I ) Check Nrv, Repaired If Defective. N ( J ) Check Cooler, Repaired If Defective. N 88 Co2 Fire Fighting System:- Carry Out Sr Yearly Routines On Co2 Fire Fighting System :- ( A ) Carry Out Survey Of Piping. Repair / Renew As Required. N ( B ) Calibrate Weighing Beam Scale ( Where Fitted ) . N ( C ) Check All Flexible Hoses For Cracks, Embrittlement And Sign Of Cracking. Renew Them After Assessing The Condition N ( D ) Overhaul Non-Return Valves And Safety Stop Valves ( Where Fitted ) . N ( E ) Remove And Inspect Cylinder Operating Heads. Test For Correct Functioning. N ( F ) Renew Bursting Discs Fitted In Pipe System ( Where Fitted ) . N ( G ) Weigh The Co2 Cylinder Using Beam Scale. If The Weight Falls Below 10% Of Initial Weight, Recharge The Cylinders. Maintain Record In Log Book. N ( H ) Admit Lp Air Into Ring Main Checking The System For ( J ) Leaks. Ensure That All The Discharge Pipes And Nozzles Are Clear. Calibrate Pressure Gauges Fitted In The System. N ( K ) Check Audio Visual Alarm Function, Limit Switches In Control Penal For Operation, Renewed If Defective . Note- Quote For Services And Material / Spares 89 Serviceability Checks Of Co2 Fire Fighting Control System To Be Undertaken And Repaired With Spares As Required. Note- Quote For Services And Material / Spares 90 Hinges To Be Provided On Chequred Plates Of Engine Room For Operating System Valves. Note- Quote For Services And Material / Spares 91 Sea Water Suction Strainers :- Remove Inspect, Clean And Paint With Epoxy Coating For Following Suction Strainers : Main Sea Chest, Bilge Suction And Da Suction. Renew If Required. Mat - Ss As Per Sample Note- Quote For Services And Material / Spares 92 System Pipelines :- Removal, Chemical Clean And Repair System Pipelines. Pressure Testing To 1.5Xworking Pressure ( Kg / Cm2 ) , Undertake Fitment Onboard And Prove For Satisfactory Performance :- Galvanised Steel ( A ) 100Mm 93 ( B ) 80Mm 94 ( C ) 65Mm 95 ( D ) 50Mm 96 Copper. ( A ) 40Mm 97 ( B ) 32Mm 98 ( C ) 25Mm 99 ( D ) 20Mm 100 ( E ) 18Mm 101 ( F ) 15Mm 102 Cu-Ni ( A ) 125Mm 103 ( B ) 100Mm 104 ( C ) 80Mm 105 ( E ) 65Mm 106 ( F ) 50Mm 107 ( G ) 40Mm 108 ( H ) 25Mm 109 System Pipelines :- Renew With End Fittings, Pressure Test To 1.5Xworking Pressure ( Kg / Cm2 ) , Fit Onboard And Prove. ( A ) Air Vent & Filling System, 150Mm 110 100Mm 111 65 Mm 112 50 Mm 113 Copper ( A ) Lub Oil & Sanitary System, 40Mm 114 32Mm 115 25Mm 116 20Mm 117 18Mm 118 15Mm 119 12Mm 120 Both Main Engine Fly Wheel Safety Guards Damaged. Guards To Be Manufactured. Note- Quote For Services And Material / Spares 121 Flap Cover Perished, To Be Renewed N ( A ) Stbd Main Engine Exhaust Funnel. N ( B ) Provision Of New Dd Compressure Exhaust Outlet Flap Cover Note- Quote For Services And Material / Spares 122 External Fire Fighting System Make-Jason Engg Ais, Modle-Sru-C255 Vk1.8Ccw-02 :- Port Fi Fi Clutch Lub Oil Cooler To Be Cleaned And Pressure Test To Be Carried Out. Serviceability Checks Of System To Be Undertaken Including Necessqary Spares. Note- Quote For Services And Material / Spares 123 Lub Oil Transfer Pump Make-Tushaco, Modle-R-20-Dg :- Pump To Be Overhauled View High Vibration. Note- Quote For Services And Material / Spares 124 External Fire Fighting System:- Actuator Of Nozzle Of Fifi System On Top Of Bridge Not Operating. Same To Be Repaired / Renewed Note- Quote For Services And Material / Spares 125 Following Defects On Fifi System N ( A ) Clutch Not Engaging In Remote Mode. Dr To Be Undertaken. N ( B ) Fifi System Pipe Line Cracked / Damaged At 08 N Locations. Leakages To Be Rectified And System To Be Pressure Tested. Dia- 300 Mm, Mat- Cu Ni N ( C ) Operating Wheels Of Fifi System Valves ( 08 Nos ) Damaged. Same To Be Renewed. N ( D ) Hydraulic Valves Of Fifi System To Be Overhauled With Spares, Size - 300Mm, Qty-02 Note- Quote For Services And Material / Spares 126 Pressure Regulating Valves N ( A ) Operating At High Pressure Than Normal ( 01 In No ) , To Be Overhauled ( Range- 30 To 5 Bar ) N ( B ) Prv Operating At High Pressure Than Normal ( 02 Nos ) , To Be Overhauled ( Range- 30 To 9 Bar ) Note- Quote For Services And Material / Spares 127 Both Ru Tank Sight Glass Damaged. To Be Renewed. Note- Quote For Services And Material / Spares 128 Overhaul Air Starting Motor Of Main Engine, Make Wartsila Note- Quote For Services And Material / Spares 129 Fresh Water System Filling Point At Weather Deck Perished Same To Be Renewed With Flanges ( Aprrox Length- 0.25 Mtr. Mat-Gun Metal, Dia-65 Mm Nnote- Quote For Services And Material / Spares 130 Repair / Renewal Of Hand Pump Fitted On Foxle Note- Quote For Services And Material / Spares 131 Following Oil Pressure Setting To Be Adjusted On Both Voith-: ( A ) Lub Oil Pressure ( B ) Control Oil Pressure , Rotor Oil Pressure. 132 Voith Turbo Schneider, Model - 21 R 5 / 150-2 :- Following Voith Parameter Not Showing In Mcr Alarm Monitor Panel:- ( A ) Control Oil Pressure, ( B ) Lub Oil Pressure, ( C ) Rotor Oil Pressure, ( D ) Bearing Oil Temperature. To Be Rectified. 133 Safety Device Checks To Be Undertaken On Both The Voith System 134 Air Starting Motor Of Port Main Engine Defective, To Be Repaired With Oem Listed Spares As Required . 135 Valves Of Various Systems :- Removal, Overhauling, Pressure Testing And Fitment Of Following System Valves:- ( A ) 65 Mm Sdnr Valve 136 ( B ) 65 Mm Sd Valve 137 ( C ) 80 Mm Gate Valve 138 ( D ) 80Mm Globe Valve 139 ( E ) 125 Mm Strom Valve 140 ( F ) 150 Mm Sdnr Valve 141 ( G ) 200 Mm Gate Valve 142 ( H ) 200 Mm Butter Fly Valve 143 ( J ) 300 Mm Butter Fly Valve 144 ( K ) 100 Mm Gate Valve 145 ( L ) 40 Mm Sdnr Valve 146 ( M ) 40 Mm Globe Sd Valve 147 ( N ) 40 Mm Sd Valve 148 ( O ) 32 Mm Sd Valve 149 ( P ) 15 Mm Sdnr Valve 150 ( Q ) 65 Mm Strom Valve 151 ( R ) 80 Mm Strom Valve 152 ( S ) 125 Mm Sdnr Valve 153 ( T ) 50 Mm Quick Shut Down Valve 154 ( U ) 50 Mm Sdnr Valve 155 ( V ) 20 Mm Sdnr Valve 156 ( W ) 25 Mm Quick Shut Down Valve 157 ( X ) 15 Mm Cock Valve 158 Remove, Dismantle, Chemically Clean, Assemble And Pressure Test To Required Pressure With Spares For The Following N ( A ) Lub Oil Heat Exchangers Of Both Main Engine N ( B ) Both Alfa Cooler To Be Insitu Dismantled, Nmechanically Cleaned And Boxed Back With New Gaskets. System To Be Pressure Tested And Proved For Operation Post Fitment Of Coolers. Test Pr- 3.5 Kg / Cm2. N ( C ) Existing Inlet And Outlet Pipe Of Both Alfa Coolers To Be Repaced With Cu-Ni Pipe. Length- 0.3 Mtr, Mat- Ss, Dia- 80 Mm N ( D ) Sea Water Inlet Pressure Guage Line Adaptor Of Both Alfa Cooler Damaged, To Be Renewed Note- Quote For Services And Material / Spares 159 Renewal Of Hot Lagging For Da And Main Engine Compartment Note- Quote For Services And Material / Spares 160 Temperature Gauges Of Various System Lines To Be Renewed. Note- Quote For Services And Material / Spares 161 Suction And Discharge Pressure Gauges Of Various System Lines To Be Renewed. Note- Quote For Services And Material / Spares 162 Overhauling Of Fire Hydrants To Be Carried Out.Note- Quote For Services And Material / Spares 163 Leakage Observed From Dirty Oil Pipe Flange. Brazing And Pressure Test To Be Carried Out. Mat-Cu Ni, Dia-50 Mm. Note- Quote For Services And Material / Spares 164 Leakage Observed From Fuel Filling Line In Engine Room. Pipe To Be Replaced. Dia-50 Mm. Lenght-0.5Mtr, Mat-Ms.Note- Quote For Services And Material / Spares 165 Port Main Engine Breather Line Cracked. Pipe To Be Renewed. Mat-Ms, Dia-85 Mm, Length-0.5 Mtr.Note- Quote For Services And Material / Spares 166 Both Da Lub Oil Temperature Increasing. Both Lub Oil Cooler To Be Cleaned And Pressure Tested.Note- Quote For Services And Material / Spares 167 Both Da Sea Water Pressure Line Perished. Line To Be Replaced. Dia-5 Mm. Lenght-10 Mtr, Mat-Copper. Note- Quote For Services And Material / Spares 168 Port Main Engine Speed Sensor No-St173 And Temperature Sensor Is Not Operational. Sensors To Be Replaced With New Sensor. Note- Quote For Services And Material / Spares 169 Lub Oil Leakage Observed From Turbo Charger Return Line. Defect To Be Rectified. 170 Fuel Centrifugal Filter Of Main Engine Defective. Fuel Centrifugal To Be Replaced. Note- Quote For Services And Material / Spares 171 Air And Co2 Bottles To Be Pressure Tested At 1.5 Times Of Working Pressure. 172 Electrical Dl:Clean Winding And Ventilation Ducts. Check Condition Of Winding Insulation Including End Connections And Renew Windings If Insulation Values Below 1 M Ohm. Check Stator Connection For Good Contact, Retighten Screws. Replace Earthing Terminals. Carry Out The Complete Overhaulling Of Excitation Panel And Replace Spares Required For Factory Designed Performance. Check For Healthiness Of Avr. Avr Tuning To Be Undertaken By Vendor If Required Based On Trial / Performance Reports. Vendor To Also Cater For Avr Replacement If Required. Load Trials To Prove Performance Of Alternator To Be Undertaken By The Vendor. Requisite Load Bank Also To Be Arranged By The Vendor. Quote For Services And Spares. 173 Navigation Control Panel To Be Overhauled And Repair Of Defective Lamps To Be Undertaken . Note- Quote For Services And Material / Spares 174 Repair Of Mb Sre Amplifier Unit To Be Carried Out 175 Emergency Lights With Assembly In Various Locations Defective. To Be Replaced With New Lights. Quote For Services And Spares. N 176 Fifi Monitor Remote Operation Non-Ops. Suspected Cable Damaged. Cable To Be Replaced And Rotary Switch To Be Renewed. Cable Specifications : 1 Sq Mm, 2 Core. Note- Quote For Services And Material / Spares 177 Carry Out Sr Routines Of All Transformers Fitted Onboard With Oem Recommended Components As Required:- ( A ) Using A Soft Brush And Vacuum Cleaner, Clean And Blow-Out Dust Nand Dirt From The Terminal Insulation Block, Between Lamination And Nthe Side And Bottom Ventilation Grills. N ( B ) Check Tightness Of All Connections And Earth Bonding Straps. Tight Loose Connections. N ( C ) Check All Lamination Securing Nuts For Tightness. Tight Loose Nuts. N ( D ) Examine Condition Of Insulation And Cable Spills For Sign Of Ncracking And Over-Heating. Change Low Insulations / Damaged Cable. N ( E ) Grease Threads Of Cover Securing Nuts And Bolts Using Anti-Seize Ngrease And Replace Covers. N ( F ) Examine Shock / Vibration Mountings, Renew If Required. N ( G ) Clean Out Using Soft Brush And Blower. N ( H ) Check All Connections And Terminal Screws Are Tight. N ( I ) Examine All Wiring For Signs Of Deterioration. Renewed Defective N ( J ) Examine Components For Over-Heating / Cracking And Capacitors Nfor Leakage. Renewed Defective Parts. N ( K ) Revarnishing Of The Coils To Be Undertaken Post Routines N N 178 Motors & Starters:- Carry Out Overhauling Of Following Motors And Starters ( Including Remote Operation ) . Motor Bearings To Be Replaced And Trials To Be Offered To Ship Staff. Rewinding Of The Motors To Be Undertaken If Insulation Values Below 1 M Ohm. Replacement Of Ber / Aber Motors To Be Undertaken As One To One Replacement. Vendor To Also Cater For Dismantling And Refitment Of The Motor. Equipment Performance To Be Restored To Factory Designed Condition. Replacement Of All Defective Parts To Be Catered By The Vendor. Note- Quote For Services And Material / Spares - ( A ) Fire & Gs P / P ( 7.5Kw ) 179 ( B ) Bilge Ballast Gs Pp ( 11Kw ) 180 ( C ) Fo Transfer Pump ( 0.75Kw ) 181 ( D ) Lo Transfer Pp ( 0.75Kw ) 182 ( E ) E / Room Supply Fan ( 7.5Kw ) 183 ( F ) Dirty Oil Pp ( 0.75Kw ) 184 ( G ) Lub Oil Cetrifuge ( 0.75Kw ) 185 ( H ) Voith Cooling Pp ( 3.7Kw ) 186 ( J ) Windlass Motor ( 5.6Kw ) 187 ( K ) Capstan Motor ( 7.5Kw ) 188 ( L ) O / Bilge Water Seperator ( 0.55Kw ) 189 ( M ) Boat Davit ( 7.5Kw ) 190 Lighting Circuit Cable And Switches ( 30 Nos ) At Various Locations Perished / Damaged. Cable / Switch Renewal To Be Undertaken. Cable Specifications 2.5 Sq Mm, 2 Core. 191 Rewinding Of 10Kva Lighting Transformers View Low Insulation Of Primary And Secondary Windings. Note- Quote For Services And Material / Spares 192 Sart Battery To Be Replaced And Instruments To Be Tested On Board. Battery Specification 12 V, 7 Ah. Note- Quote For Services And Material / Spares 193 Renewal Of 08 In No. Mob Fitted On Weather Deck, Type Lsa Code Msc 207 ( 81 ) . Note- Quote For Services And Material / Spares 194 Repair Of Navigational Lights Fitted On Main Mast Qty - 04 . Note- Quote For Services And Material / Spares 195 Replacement Of Test Equipments:- Multimeter Make- Fluke. 196 Tong Tester . Make- Fluke. 197 Analog Megger. Make- Fluke. 198 Replacement Of Battery And Hrg ( Hydrostatic Release Gear ) Of Epirb. Battery Specs - 12 V, 7 Ah.Note- Quote For Services And Material / Spares 199 Echo Sounder Calibration Including Fitting Of Hull Appendages To Be Undertaken. Printer Fitted In Wheel House Defective. To Be Replaced. Note- Quote For Services And Material / Spares 200 E / R Alarm Panel Display Monitor Not Working. To Be Replaced. 201 Split Ac Fitted In Wheel House Defective. To Be Repaired. Note- Quote For Services And Material / Spares 202 Control Batteries Of Da To Be Replaced. 12 V 120 Ah 203 Control Batteries Of Da To Be Replaced . 12 V 150 Ah 204 Control Batteries Of Da To Be Replaced . 12 V 180 Ah 205 Control Batteries Of Da To Be Replaced . 12 V 200 Ah 206 Tank Content Gauges ( Nivo System ) Not Working. Functional Checks All Gauges To Be Carried Out. Defective Components And Sensors To Be Replaced. Tank Level Calibration To Be Undertaken Thereafter. Display Module Serviceability Checks And Calibration To Be Undertaken. Replace If Ber / Defective. Quote For Services 207 Tubelight Fitted Onboard At Various Locations To Be Replaced With Led Tubelights . Note- Quote For Services And Material / Spares 208 Serviceability Of Magnetic Compass And Anemometer To Be Undertaken Followed By Calibration With Spares. Renew If Defective. Qoute For Services And Spares 209 Air Whistle Not Working. Overhauling And Repair To Be Undertaken With Oem Recommended Components As Required. Quote For Services And Spares 210 E / R General Calling Alarm Not Working. To Be Repaired 211 Spt Fitted Onboard At Various Locations Found Defective, To Be Replaced. 212 Window Wiper And Associated Mechanisms And Clear View In Wheel House Defective. To Be Renewed Including Spares. Quote For Services And Spares. 213 E / R Alarm Panel Display Key Board In Wheel House Not Working. To Be Repaired With Oem Recommended Components As Required. 214 03 In No Flood Light And 02 In No Search Light Not Working. To Be Replaced. Note- Quote For Services And Material / Spares 215 Port Main Engine Emergency Stop Push Button Is Defective At The Wheel House. To Be Replaced With New One. 216 Renewal Of Flood Lights Fitted In Engine Room With Led Lights. Note- Quote For Services And Material / Spares 217 Double Pole Switch With Single Way Are Defective. To Be Replaced With New One. Note- Quote For Services And Material / Spares 218 Deck Lights Guard / Fitting Are Broken. To Be Replaced With New One. Note- Quote For Services And Material / Spares 219 Repair Gps Display Unit Garmin With Oem Recommended Components As Required And Undertake Serviceability Checks. Note- Quote For Services And Material / Spares 220 Tru Batteries Not Holding Charge. To Be Replaced With New One 12V 180 Ah Maintenance Free Batteries . Note- Quote For Services And Material / Spares 221 Following Defective. To Be Repaired / Replaced N ( A ) Wall Mounted Fan Defective ( 20 Nos ) . N ( B ) Galley Hot Plate ( 02 Nos ) 222 5Kva Ups Defective. Batteries To Be Renewed. Battery Specification 12 V, 150 Ah ( 2 Nos ) 223 Deck Washing Machine Non Opertional To Be Renewed. Note- Quote For Services And Material / Spares 224 Lighting Switches Are Broken At Various Locations. To Be Replaced With Holder Assembly. Note- Quote For Services And Material / Spares 225 Serviceability Checks Of Navigational Radar Including Vswr And Power Output Checks. Replace Defective Transreceiver Pcb And Other Components As Necessary. Qoute For Services And Spares. 226 Hull Spares: Capstan Fixed Contacts. ( Ser No. 18 ) 227 Moving Contacts ( Ser No. 213 ) 228 Indicating Lamps ( Red ) . ( Ser No. 210 ) 229 Fuse Links ( Ser No. 206 ) 230 Controller Contacts ( Fixed ) ( Ser No. 190 ) 231 Controller Contacts ( Moved ) ( Ser No. 190 ) 232 Friction Lining For Disc Brake ( Ser No. 14 ) 233 Boat Davit Limit Switch ( Ser No. 31 ) 234 Fuse Elements ( 2A, 4A, 32A ) ( Ser No. 200 ) 235 Indicating Lamps ( Red ) ( Ser No. 206 ) 236 Push Button ( Green ) ( Ser No. 206 ) 237 Liner For Brake ( Ser No. 25 ) 238 Fuse For ( 1A, 2A, 4A, 10A, 16A, 32A ) ( Ser No. 178 ) 239 Master Controller Contact Kits ( Ser No. 177 ) 240 Contractor Kits ( Ser No. 174 ) 241 Lamps ( Ser No. 173 ) 242 Bearing For Motor ( Ser No. 179 ) 243 Friction Liner For Disc Brake ( Ser No. 14 ) 244 Gland Packing, Walker Remix ( P.No.Bba2522-879 ) ( Ser No. 26 ) 245 Indication Lamps ( Ser No. 21 ) 246 Mp Filter Hp0372a10an, Italy ( P. No. Hp0372a10an ) ( Ser No. 24 ) 247 Washer Od 100X1d 80 ( Ser No. 24 ) 248 Main Engine, Wartsilla, Model : 8L-26 Spares :- Fuel Filter ( 4761002 ) ( Ser No. 82 & 158 ) 249 Filter Paper ( 4713047 ) ( Ser No. 82 & 158 ) 250 Gasket ( 1072002 ) ( Ser No. 82 & 158 ) 251 Gasket ( 1072003 ) ( Ser No. 82 & 158 ) 252 O-Ring 20X3 ( 121007 ) ( Ser No. 82 & 158 ) 253 O-Ring ( 4712063 ) ( Ser No. 82 & 158 ) 254 Gasket ( 4712062 ) ( Ser No. 82 & 158 ) 255 Screw ( 218003 ) ( Ser No. 82 & 158 ) 256 Valve ( 2180049 ) ( Ser No. 82 & 158 ) 257 O-Ring ( 2180059 ) ( Ser No. 82 & 158 ) 258 Starting Air Pipe ( 2180063 ) ( Ser No. 82 & 158 ) 259 Sealing Ring ( 2180076 ) ( Ser No. 82 & 158 ) 260 O-Ring ( 2180077 ) ( Ser No. 82 & 158 ) 261 Washer ( 2180085 ) ( Ser No. 82 & 158 ) 262 Gasket ( 2180086 ) ( Ser No. 82 & 158 ) 263 Following Spares Main Diesel Alternator Model:6Cta8.3D / M ( Mandatory Spares ) :- Element Lub Oil ( Lube Oil Filter ) Make : Fleetguard ( 3401544 ) ( Ser No. 83 ) 264 Ring Compress ( 3919918 ) ( Ser No. 83 ) 265 Ring Compress ( 3922686 ) ( Ser No. 83 ) 266 Ring Retainer ( 3920692 ) ( Ser No. 83 ) 267 Ring, Oil Piston ( 3921919 ) ( Ser No. 83 ) 268 Regulator, Vol. Stamford Mx321, Eoo-23212 ( 2890759 ) ( Ser No. 83 ) 269 Rectifier ( 2890014 ) ( Ser No. 83 ) 270 Bearing, Main ( Thrust ) ( 3944153 ) ( Ser No. 83 ) 271 Bearing, Main ( Thrust ) ( 3944158 ) ( Ser No. 83 ) 272 Bearing Crank ( Thrust ) ( 3944163 ) ( Ser No. 83 ) 273 Valve, Intake ( 3924492 ) ( Ser No. 83 ) 274 Valve, Intake ( 3921444 ) ( Ser No. 83 ) 275 Collet, Valve ( 3901177 ) ( Ser No. 83 ) 276 Guide, Valve ( 3925863 ) ( Ser No. 83 ) 277 Injector ( 3926787 ) ( Ser No. 83 ) 278 Valve Spring ( 3991085 ) ( Ser No. 83 ) 279 Gasket, Exh. Ou; ( 3873509 ) ( Ser No. 83 ) 280 Valve Insert ( 3970278 ) ( Ser No. 83 ) 281 Bearing Connection ( 3901430 ) ( Ser No. 83 ) 282 Piston Pin ( 3934046 ) ( Ser No. 83 ) 283 Fuel Filter ( 3931063 ) ( Ser No. 83 ) 284 Valve Insert ( 3908830 ) ( Ser No. 83 ) 285 Element Air Cleaner ( 3814313 ) ( Ser No. 83 ) 286 Element Air Cleaner ( 3814312 ) ( Ser No. 83 ) 287 Gasket Set ( Gasket Turbo ) ( 3755843 ) ( Ser No. 83 ) 288 Belt V Ribbed ( 3289124 ) ( Ser No. 83 ) 289 Seal, Valve St ( 3927642 ) ( Ser No. 83 ) 290 Bolt, Connection ( 3928870 ) ( Ser No. 83 ) 291 Nut Connection ( 3934864 ) ( Ser No. 83 ) 292 Pump Fuel Injector ( 5263870 ) ( Ser No. 83 ) 293 Tube Injector ( 5271935 ) ( Ser No. 83 ) 294 Sensors, Pr. ( 2 To 10 Bar ) ( 4911882 ) ( Ser No. 83 ) 295 Sensors ( Temperature ) ( 4911877 ) ( Ser No. 83 ) 296 Pump, Sea Water ( 4963510 ) ( Ser No. 83 ) 297 Seal Oil ( 3942535 ) ( Ser No. 83 ) 298 Seal Oil ( 5259499 ) ( Ser No. 83 ) 299 Seal Injector ( 3909886 ) ( Ser No. 83 ) 300 Gasket Exhaust ( 3932063 ) ( Ser No. 83 ) 301 Gasket Gear , H ( 3944293 ) ( Ser No. 83 ) 302 Gasket Cover ( 3939258 ) ( Ser No. 83 ) 303 Gasket Hydraulic ( 3940245 ) ( Ser No. 83 ) 304 Gasket Cylinder ( 3938267 ) ( Ser No. 83 ) 305 Washers Lock ( 611 ) ( Ser No. 83 ) 306 Screw Hex, Flange ( 3243948 ) ( Ser No. 83 ) 307 Plug Pipe ( S911b ) ( Ser No. 83 ) 308 Hardness Wiring ( 3875359 ) ( Ser No. 83 ) 309 Control Governor ( 3974704 ) ( Ser No. 83 ) 310 Washer Plain ( 640 ) ( Ser No. 83 ) 311 Nut Heavy Hex ( 204 ) ( Ser No. 83 ) 312 Screw Haxagon ( 112C ) ( Ser No. 83 ) 313 Washers Plain ( S602 ) ( Ser No. 83 ) 314 Washers Lock ( 604 ) ( Ser No. 83 ) 315 Clamp Hose ( 43828 ) ( Ser No. 83 ) 316 Brace, Tube ( 101470 ) ( Ser No. 83 ) 317 Clip ( 107460 ) ( Ser No. 83 ) 318 Screw Hexagon ( 109 ) ( Ser No. 83 ) 319 Connection Ex ( 3814793 ) ( Ser No. 83 ) 320 Flange, Weld ( 3226087 ) ( Ser No. 83 ) 321 Clip ( 500694 ) ( Ser No. 83 ) 322 Screw Hexagon 112C ) ( Ser No. 83 ) 323 Screw Hexagon ( 1137 ) ( Ser No. 83 ) 324 Nut Hex Heavy ( 204 ) ( Ser No. 83 ) 325 Nut Hex Heavy ( 203 ) ( Ser No. 83 ) 326 Washers Lock ( 604 ) ( Ser No. 83 ) 327 Washers Lock ( 611 ) ( Ser No. 83 ) 328 Washers Plain ( 640 ) ( Ser No. 83 ) 329 Gasket Exhaust Ou 2880039 ) ( Ser No. 83 ) 330 Gasket Dia 135 Pcd 115 Dia ( 3940245 ) ( Ser No. 83 ) 331 Washer Plain ( 640 ) ( Ser No. 83 ) 332 Connection Se ( 2867840 ) ( Ser No. 83 ) 333 Connection Se ( 2867838 ) ( Ser No. 83 ) 334 Tools :-½ Breaker Bar-15’’ Long ( Ser No. 83 ) 335 Procurement Of Following Spares Of Voith Turbo Schneider Propulsion Type Vsp 28R5 / 234-2Ae45 Kw Rpm ( Mandatory Spares ) :- Shaft Seal Ring Adck-300X340x16 ( H01.067195 ) ( Ser No. 84 ) 336 Round Cord Ring V-420X4.5Nbr70 ( H01.086366 ) ( Ser No. 84 ) 337 O - Ring 560X5 Nbr70 ( H01.032840 ) ( Ser No. 84 ) 338 O- Ring 454X8 Nbr 70 ( H01.064102 ) ( Ser No. 84 ) 339 Bulb Lamp 35X18.5-24V 5W ( H01.095322 ) ( Ser No. 84 ) 340 Filter Element Hydac 12782361300R020 ( H01.016221 ) ( Ser No. 84 ) 341 Repair Kit ( H01.012435 ) ( Ser No. 84 ) 342 Alfa Laval Fuel Oil Centrifuge:- Major Service Kit - 546670-07-08 343 Ows Make-Suyash, Modle-Sd0.5:- Cover Gasket ( 8320025002 ) ( Ser No 86 ) 344 Coaleser Element ( 2704002501 ) ( Ser No 86 ) 345 Sacrificial Anode ( 6453020001 ) ( Ser No 86 ) 346 Set Stuffing Box-Packing ( 546040207Ep1 ) ( Ser No 86 ) 347 Desicator Cartridge ( 51110Em027 ) ( Ser No 86 ) 348 Reciprocating Air Compressors Make Elgi ( Model Hp 10 300 ) :- V Belt ( 000905283 ) ( Ser No 87 ) 349 Inlet Air Filter ( 022100929 ) ( Ser No 87 ) 350 Gasket Free End Civer ( 020365450 ) ( Ser No 87 ) 351 Gasket Fly End ( 000425510 ) ( Ser No 87 ) 352 Gasket Valve Flate ( 000411530 ) ( Ser No 87 ) 353 Valve Finger Type ( 0003300950 ) ( Ser No 87 ) 354 Valve Finger Type ( 000330970 ) ( Ser No 87 ) 355 Gasket ( 0001004A ) ( Ser No 87 ) 356 Anchor Windlass:- Packing For Top Cover ( 02211-6235-1015 ) ( Ser No. 19 ) 357 Friction Lining For Slipping Clutch ( 02-18-6232-Sc-875240 ) ( Ser No. 19 ) 358 Spring For Slipping Clutch ( 02-18-6232-Sc-875270 ) ( Ser No. 19 ) 359 Rivets For Friction Lining ( 02-18-6232-Sc-875 ) ( Ser No. 19 ) 360 Friction Lining For Emb ( B-Emb-2451-B-3024 ) ( Ser No. 19 ) 361 Rivets For Friction Lining ( A-Emb-1900-180-3092 ) ( Ser No. 19 ) 362 Spring For Emb ( B-Emb-2451-B-3017 ) ( Ser No. 19 ) 363 Procurement Of Following Maintenance Free Lead Acid Batteries ( A ) 120 Ah - 12 Nos ( Ser No. 19 ) 364 ( B ) 150 Ah - 12 Nos ( Ser No. 19 ) 365 ( C ) 180 Ah - 12 Nos ( Ser No. 19 ) 366 ( D ) 200 Ah - 10 Nos ( Ser No. 19 ) 367 Fuse ( 0219-6232-9000-F1-F10 ) ( Ser No. 19 ) 368 Indication Lamp ( 02-19-6232-9000-H1-H2 ) ( Ser No. 19 ) 369 Service Charge For Third Party Inspection ( For Hull Survey And Qc )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
43.
Defence #8605267 AOC
Tender For Comprehensive Maintenance Repairs To Certain Ac Plants And Connected Items At Mh Under Ge East Jrc; 1 Material and labour for de-scaling of condenser unit/evaporator unit (Water cooled type) 50 TR central type AC plant unit with copper tubes by removing nuts & bolts of side cover plates, water connection and filling up of de-scaling chemical in condenser and manually cleaning of copper tubes with using long Nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, tightening side cover plates with nut, bolts and making necessary connectionscomplete all as specified and as directed. (OT AC Plant in MH) 2 M&L forservicing of Air handling unit5000/8000 CFM of central AC plant by removing filters, assembling filters and testing for the following parts. (a)Inspect filters, removing and cleaning by using vaccum cleaner, blower and refixing the same. (b) Clean cooling coil, fins byusing caustic soda and water pressure method and applying Grease for all motors, check and adjust belt tension if required, check condition of blower shaft, impeller and bearings, tightening of all electrical terminations, clean water line strainers, check proper balancing system , check for noise and vibration.(c)Check healthy operation of controls and safety devices. 3 M&L forservicing of compressor unit 50TR capacity of central AC plant by removing filters, assembling filters and testing for the following parts. (a) Inspectfilters, removing and cleaning by using vaccum cleaner, air blower and refixing the same. (b) Inspect solenoid valves, pressure sensors.(c) Check healthy operation of controls and safety devices. 4 Taking down the old discharge/suction/oil pressure sensor and Supply and fix new discharge pressure sensor testing and commissioning 0-25 bar or range as existing at site, output 4-20 mA with connection nipple as per site req. for existing 50 TR compressor ofMake VOLTAS 5 Taking down the old oil filter and supply and fix new oil filter, testing and commissioning for 50 TR compressor make VOLTAS 6 Taking down the old liquid line filter and supply and fix new liquid line filter, testing and commissioning for 50 TR chiller unit of Make VOLTAS. 7 Taking down the old safety valve and supply and fix new safety valve and replacement of gasket, testing and commissioning for 50 TR chiller unit of make VOLTAS. 8 Taking down the old solenoidvalve and supply and fix new solenoid valve, operating voltage as per existing, testing and commissioning for 50 TR chiller unit of make VOLTAS. 9 Taking down the old copper coil of solenoid valve and supply and fix new copper coil, operating voltage, testing and commissioning for 50 TR chiller unit of make VOLTAS.. 10 Taking down the old suction filter and supply and fix new suction filter, testing and commissioning for 50 TR chiller unitof make VOLTAS. 11 Taking down the old sensor and supply and fix new chilled water sensor of speed matching to existing, testing and commissioning for 50 TR chiller unitof make VOLTAS. 12 Supply and fixing in replacementthermalexpansionvalvesuitableforcentral water cooled chiller type ACplantunit 50 TR of make VOLTAS capacitycompleteall as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol or equivalent. 13 Supply and filling in fresh compressor oil N-68 for compressor of AC plant of various capacities to ensure the development of required oil pressure complete all as specified or as directed by Engineer-in-Charge.Make :- Indian oil/ Bharat Petroleum/ Servo or equivalentNote :- Compressor oil shall be supplied in company sealed containers only. 14 Supply and fixing in replacement compressor shaft oil seal of50 TR Voltas make compressor unit .Make-Voltas or equivalent. 15 Servicing of cooling tower of capacity 100 TR plant by replacement of blocked/broken nozzles, checking of Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as specified and directed. 16 Supply and fix in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioningplant installed at various locations complete all as specified or as directed.Make:- Daspass/Lazer/Usha 17 S&F Pre filter 100% washable synthetic non woven supported by aluminium mesh on one side & HDPE mesh on other side of size 460 x 510 x 50mm having dust filtration level 5 micron 95% efficiencyas per existing type, make and size complete all as specified and as directed.(OT FA-6, LR-12) 18 S&F Pre filter 100% washable synthetic non woven supported by aluminium mesh on one side & HDPE mesh on other side of size 420 x 510 x 50mm having dust filtration level 5 micron 95% efficiencyas per existing type, make and size complete all as specified and as directed.(ICU) 19 S&F HEPA (High-Efficiency Particulate Air) filter of size 24 x 24 x 12 constructed withgalvanised steel frames box type having dust filtration level 0.3 micron 99% efficiencyas per existing type, make and size complete all as specified and as directed.Make for srl item No. 17 to 19 Mechmaark/Spectrum/American Air filters 20 Design, Supply,installation, testing and commissioningoffactory built, weather proof, floor mounteddouble skin chilled water type, Air handling unit (AHU) Cabinet Type, with Filters having Airhandlingcap 6500 CFM , SP 125mm wg complete with specifications and capacities as under :-(a) Panel Construction and Casing.(b) Frame:Thermal break aluminium profile with thermal barrier with 25 mm thick panels.Frame should be assembled using glass fibre reinforced nylon joints/ corner.(c) Panel:Panel shall be double construction, CFC free PUF insulation panel 25+-2mm thick having density 40 ± 2 Kg/M3. factory injectedby injection moulding machine. Outer skin-----0.8 mm thick pre coated GI sheet. Inner skin ----0.8 mm thick plain GI sheet.(d) AHU shall have Water Tight Positive Pressure access/ service door duly interlocked with fan. AHU shall have Thermallyinsulated totally sealed glass inspection window.Door shall be hinged type, hinged shall be casted powder coatedzinc alloy. Flush Lock and Handle shall be of glass fiber reinforced polyamide . Inspection lamp with limit switch.(e) Base Frame : Base frame made of G.S.S.(f)The dampers shall be made of low leakage Aerofoil design in Aluminium Anodised.OLd AHU unit to be dismantled and deposited to MES yard withut any extra cost, Rate to be quoted accordingly 21 Servicing of packaged type AC of capacity 2 x 5.50 TR such as cleaning of fine filter with water, checking Gas pressure and check for any gas leakage, cleaning of condensing coil & cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking & tightening of all electrical connections complete all as directed.Location-7011 EMENote: The servicing of One complete AC plant consisting of two units of same cap shall be measured as One UNIT. Servicing shall be done by OEM Rate should be quoted accordingly 22 Servicing of packaged type AC of capacity2 x 11TR such as cleaning of fine filter with water, checking Gas pressure and check for any gas leakage, cleaning of condensing coil & cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking & tightening of all electrical connections complete all as directed.Location- 21 WEUNote: The servicing of One complete AC plant consisting of two units of same cap shall be measured as One UNIT. Servicing shall be done by OEM Rate should be quoted accordingly 23 Servicing of packaged type AC of capacity 3 x 15 TR such as cleaning of fine filter with water, checking Gas pressure and check for any gas leakage, cleaning of condensing coil & cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking & tightening of all electrical connections and testing for satisfactory functioning complete all as directed.Location -ICU RoomNote: The servicing of One complete AC plant consisting of two units of same cap shall be measured as One UNIT. Servicing shall be done by OEM. Rate should be quoted accordingly 24 Servicing of packaged type AC of capacity3 x 22 TR such as cleaning of fine filter with water, checking Gas pressure and check for any gas leakage, cleaning of condensing coil & cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking & tightening of all electrical connections and testing for satisfactory functioning complete all as directed. Location-labour RoomNote: The servicing of One complete AC plant consisting of two units of same cap shall be measured as One UNIT. Servicing shall be done by OEM. Rate should be quoted accordingly 25 Servicing of walk-in cooler of capacity 9000 ltr with PUF panel cabin such as checking Gas pressure and for any gas leakage, cleaning of condensing/evaporating coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, Cleaning and washing of complete indoor and outdoor unit and PUF cabin, cleaning of condensers unit, checking tightening of all electrical connections and testing for satisfactory functioning complete all as directed.Location- Patient Cook House/ QM Store 26 Servicing of Cold store unit of capacity 2x5.5 TR / 2 X 8.5 TR such as checking Gas pressure and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motor, cleaning of condensers unit, checking tightening of all electrical connections and testing for satisfactory functioning complete all as directed.Note: The servicing of One complete AC plant consisting of two units of same cap shall be measured as One UNIT. Servicing shall be done by OEM i.e bluestar. Rate should be quoted accordingly Location- Medical Ward & Blood Bank 27 Preparation of old painted surfacesof AC plant central type of capacity 3 x 50 TR including all motors, condensers, pumps, MS Pipes of various sizes, cooling tower painting with super enameled paint of approved colour & superior quality with spray gun two coats incl preparation of surfaces and scraping old paint, filling cavities incl marking directional arrows for flow identification complete all as specified and as directed. 28 M&L for disconnecting electric motor 7.5HP, taking down and transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator dulyvarnished and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge. 29 All as per srl item No 28 here-in-before but of 5 HP electric motor. 30 All as per srl item No 28 here-in-before but of 3 HP electric motor. 31 Repair/ maint by Dismantling the mono block pump set with motor any make, 7.5 HP capacity, servicing by cleaning, lubricating and by replacing of ball bearing, gland bolt, nut and washers, terminal connector, machining of shaft, gasket, gland rope, mounting bolts, reassembling, refixing with bed and testing complete all 32 Taking down blower with motor of AHU/Package type AC any capacity, repair by cleaning , lubricating , filling of metal, machining/ grinding of shaft to match size, replacement of ball bearing, mounting bolts, reassembling and testing complete. 33 M&L for replacement of Fan blade heavy duty type of condensor fan motor of of capacity 250W to 500W as per existingsize all as specified and directed. 34 M & L Check for any refrigerant leaks through flare joints, valve glands or any of the loc in refrigerantsystem with help of leak detector device, soap solution,halide torch or electronic leak detector and arresting leakages including necessary welding, brazing works binding with teflon tape as required at site andtopping up the gas for required suction & discharge pressurefor50 TR unit of central type AC Plant.Note : Refrigerantshall be measured and paid seperately. 35 Material and labour for charging Nitrogen Gas in 50 TR capacity chiller unit of centralAC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof, vaccumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours & gas charging complete all as specified and as directed. Note : Refrigerantshall be measured and paid seperately. 36 M&L for Over voltage, undervoltage protection relay complet of make L&T/ GIC/ Siemens/ Minilec/ Schneider/ C&S complete. 37 Supply and charging refrigerant Gas R-22 forAC plant of various capacities including maintaining proper pressure after filling of refrigerant Gas for proper functioning of plant complete all as specified or as directed by Engineer-in-Charge. 38 Supply and charging refrigerant Gas R-407 forAC plant of various capacities including maintaining proper pressure after filling of refrigerant Gas for proper functioning of plant complete all as specified or as directed by Engineer-in-Charge. 39 Supply and charging refrigerant Gas R-410 a forAC plant of various capacities including maintaining proper pressure after filling of refrigerant Gas for proper functioning of plant complete all as specified or as directed by Engineer-in-Charge. 40 Supply, install, testing and commisioning of microprocessor type Chiller control unit with display board complete set suitable for 50 TR water chiller unit of central type AC plant make VOLTAS as per existing pattern for making plant functioning satisfactory incl all connections complete all as directed. Make : Softhard or equivalent as approved by GE. 41 Supply, install, testing and commisioning ofPackage type AC microprocessr type control unit with display board complete set suitable for 15 TR / 22 TRmulti-unit package AC plant as per existing pattern for making plant functioning satisfactory incl all connections complete all as directed. Make : Softhard or equivalent as approved by GE. 42 Supply and fixing in replacement Water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york 43 Supply and fixing in replacement of V- belt B-76 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Dunlop or equivalent 44 Supply and fixing in replacement in replacement of V- belt A-29 to A-45 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Dunlop or equivalent 45 Supply and fixcompressor 7.5 TR, model 06D/ 018 for Voltas Packaged AC plant unitand testing complete installed at ICU AC plant all as per specified and directed. 46 M&L for disconnecting all connections of semi hermetic compressor cap 7.5 TR of Voltas Model No. 6D-18 of package type AC plant, taking down and transporting to workshop, dismantling the same and taking out motor assembly removing burnt winding coil, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator dulyvarnishing and insulated with superior quality insulation material, replacement of minor parts if required, reassembling the compressor, shifting to work site and fixing & connecting with the system, charging the refrigerant/ Gas, testing complete all as specified and as directed by Engineer-in-Charge.Note : Refrigerantshall be measured and paid seperately. 47 M&L for disconnecting all connections of semi hermetic compressor cap 7.5 TR of Voltas model No. 6D-18 of package type AC plant, taking down and transporting to workshop, dismantling the same and taking outcompressor assembly, replacement of required parts , reassembling the compressor, shifting to work site and fixing & connecting with the system, charging the refrigerant/ Gas, testing complete all as specified and as directed by Engineer-in-Charge.Note : Refrigerantshall be measured and paid seperately. 48 M&L for disconnecting all connections of hermetic compressor cap 11 TR of package type AC plant, taking down and transporting to workshop, dismantling the same and taking out motor assembly removing burnt winding coil, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator dulyvarnishing and insulated with superior quality insulation material, replacement of minor parts if required, reassembling the compressor, shifting to work site and fixing & connecting with the system, charging the refrigerant/ Gas, testing complete all as specified and as directed by Engineer-in-Charge.Note : Refrigerantshall be measured and paid seperately. 49 M&L for disconnecting all connections ofhermetic compressor cap 11 TR of Voltas make of package type AC plant, taking down and transporting to workshop, dismantling the same and taking outcompressor assembly, replacement of required parts , reassembling the compressor, shifting to work site and fixing & connecting with the system, charging the refrigerant/ Gas, testing complete all as specified and as directed by Engineer-in-Charge.Note : Refrigerantshall be measured and paid seperately. 50 Supply and fixing in replacement connecting and testing of compressor scrolled sealed unit of capacity 11 TR performer,forPackage AC plant includinggas charging and testingcomplete installed at Labour room all as specified and as directed. 51 Supply and fixing in replacement connecting and testing of compressor scrolled sealed unit of capacity 5.5 TR performer,forPackage AC plant/cold storeincludinggas charging and testingcomplete all as specified and as directed. Note:Refrigerantshall be measured and paid seperately under relevant item. 52 Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make. 53 Supply and fix in replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter. Make L&T/ GIC/ Legrand/ Minilec or equivalent. 54 Taking down defective PCB of 50 TR water cooled chiller unit, making neccesary repair work and make it fully functional and fixing, testing complete all as specified and directed. 55 Taking down defective PCB of 5.5 to 22 TR, making neccesary repair work and make it functional all as specified and directed. 56 Supply and fixing in replacement Contactor, upto 10 amp 3 pole, coil voltage as per existing model complete all as specified and directed. 57 Supply and fixing in replacement Contactor, 12-22 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. 58 Supply and fixing in replacement Contactor, 32-45 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. 59 Supply and fixing in replacement Contactor, 63 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. 60 Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample. 61 Supply and fixing in replacement of pressure switchLP/HP cut out M15 as per sample. 62 Supply and fixing in replacement over load Relay 6 to 10 Amp 63 Supply and fixing in replacement over load Relay 10 to 15 Amp 64 Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant / cold storecapacity 5.5 TR / 7.5TR / 11TR as per existing type and size including taking out old unserviceable motor complete all as per specified and directed. 65 Supply, fixing, connecting, and testing in replacement evaporatorfan motor of cold store capacity 5.5TR / 7.5 TR/ 8.5 TRas per existing type and size including taking out old unserviceable motor complete all as per specified and directed. 66 Supply, fixing, connecting and testingin replacementmolecular drier cum strainer on line type of size 3/8 x 3/8 make Danfoss in AC plant capacity 5.5 TR / 7.5 TR / 11 TR as per existing type and size including taking out old unserviceable drier complete all as per specified and directed. 67 Supply, installation of GI construction Volume control Dampers, lever operated type as per existing size and specifications including required accessories, taking down old dampercomplete all as specified and as directed. 68 S & Fix Fabrication of Aluminium duct incl Supply, assembly and erection of aluminium sheet 20 gaugerectangular/square duct made out of L shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc including taking down old duct complete all as specified and directed.Location ICU ward 69 Supply,installation,testingandcommissioningofclosedcellNitrilerubber insulation 15mm thick of density min 40 - 60 kg/m3 with proper adhesive and sealed with 75 mm wide BOPP Tape on all longitudinal/transverse jointson ducts complete as per specifications. 70 Supply and Application of internal acoustic lining of 10 mm thick over supplyairducting using open cell nitrile rubber insulation with density within 30-40 Kg/m3 as per theapprovedshopdrawingsandspecifications.Insulationmaterialshallbe bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. Make : Supreme/UP Twiga/Kflex/Armaflex 71 Fabrication of PGI duct incl Supply, assembly and erection of GI sheet 26 gauge with C &SS rectangular/square duct made out of L shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge including taking down old duct complete all as specified and directed. 72 M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 40MM thickness of insulation complete all as specified and directed. 73 S & F in replacementrolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc., quality confirming to GDE Fe-410-w for cooling tower repair and pump mounting base incl cutting, drilling, welding to make required structure and painting with two coats of synthetic enamelled paint over a coat of red oxide complete all as specified and as directed. 74 S&F in replacement Flanged butterflyvalve for MS pipe heavy grade 150mm dia bore all as specified and directed. 75 S&F in replacement Flanged butterflyvalve for MS pipe heavy grade 100mm dia bore all as specified and directed. 76 Material and labour for cold water pipe insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 40MM thickness of insulation as specified 77 Supply, install, testing in replacementGI pipe medium grade 20mm dia laid in floor/ wall including neccessary GI fittings complete all as specified and directed. 78 Supply and fix in replacement Brass ball valve suitable for 20mm GI pipe complete all as specified and directed.Note: for item No. 1 to 78 (a)The above mentioned items will be replaced based on day to day complaints and no extra cost will payable for attending complaints. Contractor will quote the rate accordingly.(b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor.(e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints and handing over the same to complaint cell after rectification duly signed by user with details of stores fixed after attending/ completion of the job on the same day. (f) Contractor shall handover min 40% of these items within one month to 45 days after commencement of workto concerned JE incharge which will be issued for fixing on the basis of day to day complaints. The recovery of Rs 1500 per day shall be levied in case of default. 79 Supply & Fixing linear type aluminium air grill for supply/return air complete with OBSS damper all as specified & directed. 80 M & L for PUF insulation of thickness 60 MM thick rigid polyurethen foam (PUF) panelinsulation havig PPGI finsh with sheet thickness 0.4 mm on both sides,fro made swing type door as of existing size to maintain temperature range+2 to +6 degree complete all as specified and directed. 81 Supply and Fixing in replacement the 7.5 Ton out door air cooled copper tube condensor coil tubes of copper only power supply 415 V 3 PH 50 Hz suitable for package AC 2*15 TR complete all as specified and directed. 82 Attending breakdown(except periodical maintenace) by skilled Ref Engineer & Mechanic for any type package AC plant/cold store of capacity 5 TR to 22 TR, diagonising the fault, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting andrefixing of LT cables etc as required to make the system functional in minimum time by deploying sufficient technician alongwith with helper incl necessay T & P complete all as specified and directed. 83 Attending breakdown(except periodical maintenace) by skilled Ref Engineer & mechanic for centre AC plant of capacity 3*50 TR diagonising the fault, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting andrefixing of LT cables etc as required to make the system functional in minimum time by deploying sufficient Engineer/ technician alongwith with helper incl necessay T & P complete all as specified and directed. 84 Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and gettingout complete all as specifiedand directed by Engineer-in-Charge. 85 Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge. 86 Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engr-in-charge. 87 Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. 88 Supplying and laying Factory made un-reinforced precast concrete cable cover ISI marked, class LV, type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed. 89 Supplying, laying, jointing and testing in replacement1100 volts grade LT underground XLPE insulated armoured PVC sheathed heavy duty electric cable of size 70 Sqmm 3.5 core with stranded aluminium conductor, laid in trenches, in floor, in duct, cable tray ,through pipes or along the pole including taking up existing defective cable complete all as specified and directed. 90 Ditto as per item No 89 above but of size 25 sqmm 3.5 core 91 Ditto as per item No 89 above but of size 35 sqmm 3.5 core 92 Ditto as per item No 89 above but of size 50 sqmm 3.5 core 93 Ditto as per item No 89 above but of size 16 sqmm 4.0 core 94 S & Fin replacement MCCB 400 Amps, 4 pole, 50 kA with Adjustable thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader linksand required nut, bolts or other fixing accessories complete. 95 S & Fin replacement MCCB 250 Amps, 4 pole, 35 kA with Adjustable thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader linksand required nut, bolts or other fixing accessories complete. 96 S & Fin replacement MCCB 200 Amps, 4 pole, 35 kA with Adjustable thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader linksand required nut, bolts or other fixing accessories complete. 97 S & Fin replacement MCCB 160 Amps, 4 pole, 25 kA with Adjustable thermal magnetic release, Ics = 75% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader linksand required nut, bolts or other fixing accessories complete. 98 S & Fin replacement MCCB 100 Amps, 4 pole, 16 kA with Adjustable thermal magnetic release, Ics = 75% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader linksand required nut, bolts or other fixing accessories complete. 99 M & L for in replacement MCB SPN 63 A, 230 V, having rupturing capacity 10 KA, of rating complete all as specified and directed.. 100 Material and labour in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sideswith alternative layers of charcoal dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 cm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipeearth wireprotected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shown in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indicated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCCcovered with CI cover hinged with frame including excavation and earth work complete all as specified and directed. 101 S & F in replacement25 mm x 3 mm aluminumstrip as earth continuity conductor including fixing from test point to equipement complete all as speicified & directed by Engineer-in-charge. 102 Supply and fixing in replacementof structural Iron work for fabricating, construction of fire stand,Iron ladder, MS railing, support structure, pit cover with angle iron frame, MS blank flange of suitable dia having reqd holessuitable size as existing at different site including nuts, bolts, washers, cutting, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed 103 Supply and Fixing in replacementof powder coated MS cable tray of size 40mm*100mm*40mm of thickness 1.6 mm of perforated type with perforation not more than 17.5 % in conventional sections, joined with connecters, suspended from ceiling /wall with M.S. suspenders including nuts, bolts, copper wire /LT Cable complete all as specified and directed 104 Supply and Fixing in replacementof powder coated MS cable tray of size 50mm*300mm*50mm of thickness 1.6 mm of perforated type with perforation not more than 17.5 % in conventional sections, joined with connecters, suspended from ceiling /wall with M.S. suspenders including nuts, bolts, copper wire /LT Cable complete all as specified and directed
Contract Date: Jan 16, 2026 Contract Value : 31.72 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
44.
Defence #8596997 AOC
Tender For Maintenance And Repair Of E/M Services For Mh Area Under Ge Gwalior; 1 Taking down following defective items fromThree Phase 5kVA Online UPS invertorand S&F following Items with testing and commissioning as directed by Engn-in-charge. 2 IGBT Modules-Cards 3 PCB cards like IC’s, Transistors, relays, SCR’s resistances etc 4 Sensing Transformers for circuits 5 Main Transformer 6 Rewiring of UPS systems including cable/solder etc. 7 Digital Display Cards Meter 8 Battery Re Charging Onsite of Existing batteries with a heavy duty CCCV Type Charger- SMF 12Volts. 9 Control switch 10 Cooling Fans/Circuit 11 Capacitor Bank 12 Input /Output Terminations 13 2 Pole 4 Way 30 Amps By Pass Switch 14 Main Control Card 15 Protection Card 16 Power Supply /SMPS Card 17 Charger Cards 18 SCR-SCR Modules 19 M&L for repair & maintainance and servicing of Air Compressor, 440V,3 Phase ,50 hz,capacity of upto 12.5 HPand renewal of all unsv part if any in air compressor system and renewaloil and gasket for smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 20 M&L for repair & maintainance and servicing of Vaccum Compressor ,440V,3 Phase ,50 hz,capacity of upto 12.5 HPand renuwal of all unsv part if any in Vaccum compressor system and renewaloil and gasket for smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 21 M&L in renewal suction valve of Vaccum/Air Compressor, 440V,3 Phase ,50 hz, capacity of upto 12.5 HPsmooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 22 M&L repair & maintainance and servicing of Air Drier System capacity of 100 CFMand replace all unsv part if any in Air Drier System for smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 23 M&L in renewal of Solenoid valvein Air Drier System capacity of 100 CFM for smooth functioning installed at MH thatcomplete all as specified and directed. 24 M&L repair & maintainance and servicing of Diesel Engine Fire pump System ,440V,3 Phase ,50 hz,capacity of upto 12.5 HPand renewal all unsv part if anyfor smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 25 M&L repair & maintainance and servicing of Electrical driven fire pump System,440V,3 Phase ,50 hz,capacity of upto 12.5 HPand renewal all unsv part if anyfor smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 26 M&L repair & maintainance and servicing of fire jockey pump System 440V,3 Phase ,50 hz,capacity of upto 12.5 HPand renewal all unsv part if anyfor smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 27 M&L repair & maintainance and servicing of Fire control pannel System,440V,3 Phase ,50 hz, ,230 Volt,50 Hz,and renewal all unsv part if anyfor smooth functioning installed at MH that all unsv part quated including in this job complete all as specified and directed. 28 M&L in renewal Non return valve 100/150 mmsize inclding assessories item like screw, nut gasket etc.complete all as specified and directed. 29 M&L for Taking out old defective burnout motor of capacity 5 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enamelled copper wire of existing size & gauge and renewal of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning complete all as specified and directed. 30 M&L for Taking out old defective burnout motor of capacity 7.5 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enamelled copper wire of existing size & gauge and replacement of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning complete all as specified and directed. 31 M&L for Taking out old defective burnout motor of capacity 12.5 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enamelled copper wire of existing size & gauge and replacement of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning complete all as specified and directed. 32 S&Fin renewalfully automatic star delta starter suitable for upto 15 HP AHU Motor/Centrifugal Pump Set Motor 415 volts 50 Hz Panel Mounting complete with contactor and suitable thermal relay complete all as specified and directed 33 M&L in renewal Automatic Bar Pressure Switch for air /vacuume pressure system complete all as specified and directed. 34 M&L in renewal power contactor for star delta starter upto 15 hp motor complete all as specified and directed. 35 M&L in renewal Thermal Relay for star delta starter upto 15 hp motor complete all as specified and directed. 36 M&L in renewal Butterfly valve upto size of 150mm dia pipe including assessories item like screw,nut,gasket etc provide by contractor complete all as specified and directed. 37 M&L in renewal Hose reel drum 30 mtr length upto dia 100 mm with male female coupler as same size complete all as specified and directed. 38 M&L in renewal Hose box made of 18 gauge MS Sheet 800mm x 600mmx 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS Sheet painted fire red out side and brilliant white inside yard compled all as specified and directed. 39 M&L in renewal for Hydrant valve size upto 150 mm the hole not less than 50 mm and the thickness shall not be less than 6 mm complete all as specified and directed. 40 M&L in renewal two way inlet breeching valve SS Hydrant valve size upto 150 mm the hole not less than 50 mm and the thickness shall not be less than 6 mm complete all as specified and directed. 41 M&L in renewal Automatic Bar Pressure Switch for Fire hydrant system completed all as specified and directed. 42 M&L for shifting the door sensor set of lift 13/15 passanger to outside the door car as per direction of Engr-in-charge complete all as specified and directed. 43 M&L in renewal ElectronicDoor sensor for Lift 13/15 Passanger and sensor have same make as per lift make and fixing will complete by Authorised person from Lift Company installed at MH complete all as specified and directed. 44 M&L in renewal Over Voltage Protector for Lift 13/15 Passanger and fixing will complete by Authorised person from Lift Company installed at MH complete all as specified and directed. 45 M&L in renewal 12 Volt ,7AH battry for ARD for Lift 13/15 Passanger and fixing will complete by Authorised person from Lift Company installed at MH complete all as specified and directed. 46 M&L in renewal Fan Motor for Lift 13/15 Passanger for fresh air and fixing will complete by Authorised person from Lift Company installed at MH complete all as specified and directed. 47 M&L in renewal Concealed Celling light for Lift 13/15 Passanger and fixing will complete by Authorised person from Lift Company installed at MH complete all as specified and directed. 48 M&L in renewalDuct of cooler with size as per site requires like AHU DUCT/DUCTABLE AC/DUCT COOLER for uniformly distribute the cool air includingall accessoriescomplete all as specified and directed. 49 M&L in renewal black insulation with aluminium foil for Duct cooler/Duct of AHU for protection outside sunlightcomplete all as specified and directed. 50 M&L in renewal FireDetectors Complying with and type certified to EN - 45 Addressable type multisensor detector Photoelectric /Optical with base with heat and smoke combination, built intelligence as per IS: 11360 complete all as specified and directed. 51 M&L in renewal Wired Nurse Call Bell System (DC Based) For Hospital,7 TFT Touch Screen based Console,Outer casing is made out of ABS Plastics,18 Channels/Rooms,Micro controller based,12; 2A Switching Mode Power Supply,Individual rest button for each room,No computer required,Custom made options for more number of beds completed all as specified and directed. 52 Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. 53 Taking down ceiling/exhaust fan of any sweep,removing blades, cleaning the fan completely of dust and dirt and Re-hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and as directed. 54 Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed. 55 Taking down unserviceable Sheet metal box & MCB DB SPN with MCBs of any make/capacity, complete all as specified and directed. 56 Taking down unserviceable TPN DBwith MCBs of any make/capacity, complete, all as specified and directed by Engr-In-Charge. 57 M&L concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxesfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etccomplete for the following:- 58 One light point controlled by one switch. 59 One Ceiling fan point controlled by one switch. 60 One Exhaust fan point controlled by one switch. 61 One 3 pin socket outlet 5 Amps controlledwith one switch on the same board. 62 One 3 pin socket outlet 5 Amp controlled by one switch on independent board. 63 Description all as per item no.40 here in before but point wiring with 2.5 sqmm FRLSHconfirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire complete all as specified and directed. 64 M&L in renewal Modular switch 1 way 6A,1 module complete all as specified and directed. 65 M&L in renewal Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. 66 M&L in renewal Modular switch 1 way 16A,1 module 15 Amp complete all as specified and directed. 67 M&L in renewal Socket 6A/16A - 6 pin combined 2 module complete all as specified and directed. 68 M&L in renewal Fan step regulator,80 to 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed. 69 M&L in renewal Ceiling rose 3 terminal/pvc/polycarbonate, isolated body complete all as specified and directed. 70 M&L in renewal Bell Ding Dong, AC, 230 Volts, single pole complete all as specified and directed. 71 M&L in renewal Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed. 72 M&L in renewal of Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. 73 M&L in renewal modular plate White cover plate with frame2/3/4 module and provising of new modular plate of different size with flush metel boxincluding fixing ,the existing modular switchs , modular socket ,modulare regulator complete all as specified and directed. 74 M&L in renewal modular plate White cover plate with frame6/8/12 module and provising of new modular plate of different size with flush metel boxincluding fixing ,the existing modular switchs , modular socket ,modulare regulator complete all as specified and directed. 75 M&L in renewal switch piano, flush button single pole one way 5 Amp complete complete all as specified and directed. 76 M&L in renewal socket outlet, 5 Pin, 6 Amp2 in 1, flush type, universal complete all as specified and directed. 77 M&L in renewal switch piano, flush button single pole one way 15 Amp complete all as specified and directed. 78 M&L in renewal socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 amps completeall as specified and directed. 79 M&L in renewal bell push flush type, 5 Amps complete all as specified and directed. 80 M&L in renewal Bell Ding Dong, AC, 230 Volts, single pole completeall as specified and directed. 81 M&L in renewal Ceiling rose 3 terminal/pvc/polycarbonate, isolated body complete all as specified and directed. 82 M&L in renewal electronic modular step rotary type fan regulator of capacity 80 to 100 Watt, 240 volts, AC 50Hz completed all specified and directed. 83 M&L in renewal Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all specified and directed. 84 M&L in renewal Switch socket combination 2 in 1, 5 A flush type in repair complete all as specified and directed. 85 M&L in renewal Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. 86 M&L in renewalModular Switch6 Ampone way complete all as specified and directed. 87 M&L in renewal ofModular socket6 Amp 3pin complete all as specified and directed. 88 M&L in renewal ofModular Switch16 Ampone way complete all as specified and directed. 89 M&L in renewal Modular socket6/16 Amp 3pin complete all as specified and directed. 90 M&L in renewal replacement, ofModularStep fan Regulator of 1/2 Module upto 120 Watt complete all as specified and directed. 91 M&L in renewal 35 watt bldg security light fittings with photoelectric sensor better optics for uniform distribution IP 65/66 protection LED Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60 mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqdlength of 1.5 Sqmm PVC multistranded BIS marked, 03/02 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed. 92 M&L in renewal 100 watt Street light fittings with photoelectric sensor better optics for uniform distribution IP 65/66 protection LED Heat resistance glass, pressure die cast aluminium housing including galvanised iron pipe light grade bracket bent to shape over all length 0.60 mtr fixedon pole complete including reqdlength of 1.5 Sqmm PVC multistranded BIS marked, 03/02 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed. 93 M&L in renewalof 100 wattLED flood light230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with Photometric sensor outdoor type 220-240 volt ambient light <5-15 lux working temparature -20~+40C working humidity <93% RH along with pvc connection of 6 to 10 amp capacity with IP66 protection and colour as per required all as specified and directed. 94 M&L in renewalpost top lantern LED type 20 watt 230 watt volts AC outdoor type as gate lightwith decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 95 M&L in renewal sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 2.5 sqmm two single core PVC insulated unsheathed FRLSH wire drawn in and including 32 mmwidth dia PVC Casing Caping medium grade including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH earth continuty wire complete all as specified and directed 96 M&L in renewal sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm two single core PVC insulated unsheathed FRLSH wire drawn in and including 32 mmwidth dia PVC Casing Caping medium grade including one run single core PVC insulated unsheathed 4 Sqmm FRLSH earth continuty wire complete all as specified and directed 97 M&L in renewal sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm two single core PVC insulated unsheathed FRLSH wire drawn in and including 32 mmwidth dia PVC Casing Caping medium grade including one run single core PVC insulated unsheathed 6 Sqmm FRLSH earth continuty wire complete all as specified and directed 98 M&L in renewal 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm x 2 Core complete all as specified and directed 99 M&L in renewal 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq.mm x 2 Core complete all as specified and directed 100 M&L in renewal sheet metal Enclosurewith socket Plug top and earth plug, single pole and neutral with single pole MCB 20 Amps 240 volts in repairs complete including taking down complete all as specified and directed. 101 M&L in renewal sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100Amp,4 pole & Including MCCB 100 amps 4 pole 16 KAcomplete with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making goodthe distributed wall surfaces to match complete all as specified and directed. 102 M&L in renewal MCB DB, sheet metal enclosures double door TPN 4 way with bus bar 415 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed 103 M&L in renewal MCB DB, sheet metal enclosures double door SPN 8 way withbus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed 104 Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable(Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 95 Sqmm 3.5 Core complete all as specified and directed. 105 -do- but 50 Sqmm 3.5 core. 106 -do- but 35 Sqmm 3.5 core. 107 -do- but 25 Sqmm 3.5 core. 108 Excavation in trenches n exc. 1.5 m wide and n exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 109 Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. 110 Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed. 111 Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed. 112 Supplying and laying un reinforced precast concrete cable coverClass LV, Type I, flat size 250mm x 150mm x 40mm complete all as specified and directed. 113 S&F 4 POLE MCCB 400 Amp, 50Hz ,415V with rupturing capacity 36 KA in repair complete all as specified and directed. 114 S&F 4 POLE MCCB 250 Amp, 50Hz ,415V with rupturing capacity 36 KA in repair complete all as specified and directed. 115 S&F 4 POLE MCCB 160 Amp, 50Hz ,415V with rupturing capacity 16 KA in repair complete all as specified and directed. 116 S&F 4 POLE MCCB 100 Amp, 50Hz ,415V with rupturing capacity 10 KA in repair complete all as specified and directed. 117 Taking down unsv ceiling fans 1200/1400 sweep 230v,AC supply,single phase from site,depositing in MES store Yard,dismantling all parts,checing serviceability of all parts & continuity of copper winding (Burn out winding fan should be staking aside for rewinding) including cleaning all the components of fan, oiling ,greesing,including replacement of rusted/unsv nuts,bolts split pin rubber reel,machine screws,shafts,capacitor,clamps etc as requried,reassembling the fan and testing complete all as specified and directed.Note :(i) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete. 118 Taking out burnt winding wire from ceiling fans(Which req rewinding) Motor of 1200/1400 mm sweep 230V AC supply,single phase,Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & sixe throughly cleaning all the components of fan, oiling,greesing,replacement of rusted/unsv nuts,bolts split pin rubber reel,machine screws,shaft etc as required reassembling the fan,testing complete & Transporting back to MES Yard complete all as specified and directed. Note :Testing should be done to repair fan minimum 24 Hrs continues running in MES store yard before fixing at site complete. 119 Taking down unsv Exhaust Fan 230/300/380/450 mm sweep 230v,AC supply,single phase from site,depositing in MES store Yard,dismantling all parts,checing serviceability of all parts & continuity of copper winding (Burn out winding fan should be staking aside for rewinding) including cleaning all the components of fan, oiling ,greesing,including replacement of rusted/unsv nuts,bolts split pin rubber reel,machine crews,shafts,capacitor,clamps etc as requried,reassembling the fan and testing complete all as specified and directed.Note:Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete. 120 Taking out burnt winding wire fromExhaust fans(Which req rewinding) Motor of 230/300/380/450mm sweep 230V AC supply,single phase,Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & sixe throughly cleaning all the components of fan, oiling,greesing,replacement of rusted/unsv nuts,bolts split pin rubber reel,machine screws,shaft etc as required reassembling the fan,testing complete & Transporting back to MES Yard complete all as specified and directed.Note : Testing should be done to repair fan minimum 24 Hrs continues running in MES store yard before fixing at site complete. 121 M&L in renewal of ball bearing(6201&6202) Suitable for Ceiling fan of any size complete all as specified and directed. 122 M&L in renewal of ball bearing(6203&6204) Suitable for Exhaust fan/Air circulator fan of any size complete all as specified and directed. 123 M&L in renewal condenser of 2.5 MFD capacity after removing existing unsv condenser from any situation complete all as specified and directed. 124 M&L in renewal condenser of 3.15/ 04 MFD capacity after removing existing unsv condenser from any situation complete all as specified and directed. 125 Taking down the water heater storage type of any make upto 50 ltrs capacity.Dismantling carefully from its position fixed on walls,descaling the inner tank,flange assembly by applying descaling solution,reassembling the same,after replacement of defective parts and reinstalling to their original location locations or as directed after commissioning and testing complete,all as direceted.Note : Any material/part found UNSV during servicing shall be replaced by the contractor and measured and paid separately under respective items. 126 Taking down the water heater for rectification of leakage in the inner shell of (Geyser)storage type of any make upto 50 ltrs capacity.Dismantling carefully from its position fixed on walls,and rectified leakage by soldering,brazing,welding at appropriate area of coppe/stainless steel inner tank of geyser and reinstalling to their original location or as direceted. Note : Any material/part found UNSV during servicing shall be replaced by the contractor and measured and paid separately under respective items. 127 M&L in renewal neon indicating lamp,rectangular/round as required at site including taking down complete all as specified and directed.. 128 M&L in renewalheating element upto 2 KW,single phase,230 volt with triangular/round base as suitable for 25/35/50 Ltr water heater complete all as specified and directed. 129 M&L in renewal thermostat switch range upto 80C suitable for 25 to 50 ltrs cap water heater complete all as specified and directed. 130 M&L in renewal PVC Connection of any make with(ISI Mark) having 10 mm dia,60cm long with steel reinforcement suitable for hot water geyser outlet supply with 02 nos of unions/cup shaped cover with washers complete all as specified and directed. 131 M&L in renewal PVC Connection of any make with(ISI Mark) having 10 mm dia,60cm long with steel reinforcement suitable for cold water geyser outlet supply with 02 nos of unions/cup shaped cover with washers complete all as specified and directed. 132 S&F in renewal 1800 Watt Pressure Washer with all accessories like Spray gun extention rod,inlet connector,inlet filter,bucket filter ,tap connector, Outlet hose 8 MTR,spray gun,foam spray bottle,Inlet pipe 3 mtr for cleaning AHU filter complete all as specified and directed. 133 S&F in renewal 1100 Watt Vacuum Cleaner and Blower ,Blue (15 litre) 3mtr long vacuum hose pipe,crevice nozzle,floor nozzle,brush inserts use for cleaning AHU filter complete all as specified and directed. 134 M & L For Descaling the Solar water heater with chemical solution complete all as specified and directed. 135 M & L for repair Solar water heater including replacingall unserviceableparts of Solar Water heater as and when required complete all as specified and directed. 136 M&L for Servicing & Maintanance ofLift (15 Passanger) Lift at New MH Gwaliorjob as per IS standard IS-14665,(2000) completedall as specified and directed. 137 M&L for Servicing & Maintanance ofLift (13 Passanger) Lift at New MH Gwaliorjob as per IS standard IS-14665,(2000) completedall as specified and directed. 138 M&L in renewalEmergency Exit light ,230 v,50 Hz.in green/red colourcomplete all as specified and directed. 139 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded BTstone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in D shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed as per MES Schedule Part I & II..
Contract Date: Jan 14, 2026 Contract Value : 35.92 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
45.
Defence #8595378 AOC
Tender For Repair Maintenance Of Dg Sets And Amf Panel Along With Fire Fighting Eqpts At Afs Madh Island Under Ge(Af)Thane.; 1 Maintenance for DG Set 250 KVA, Make - Crompton Greaves, through authorised service agency of OEM , Location :(DG SET -1, Radar Area AFS Madh) complete all as directed Note :- Spares required for above maint will be measured and paid separately under relevant items involving the following scope of works :- 2 (I) Scope of works :-(a) Check the sample of coolant concentration(b)Check the fan belt for tension and replace if needed.(c ) Check exhaust condensate drain and remove any debris or dust.(d)Examine the charge level of battery and check for any loose connection and de-scale carbon deposits if any on terminals and application petroleum jelly.(e)Check the air cleaner components and clean the dirt with air pressure.(f)Check and adjust the voltage level of the battery charger.(g) Drain out the water from the container of the bottom of the filter housing and fuel tank.(h)Check the control panel wiring, Instrumentation, contacts fuses, etc.(j)Check the specific gravity of battery every month and condition of Plates once in three months.(k)Check the serviceability of safety controls of Engine.(l)Checking of all electricalconnectons for its proper tightness.(m)Check AVR connections & power cable connections for tightness.(n)Check RPM/Frequency and adjust it.(o)Checking of Loadbalancing of alternator/AMF panel output(p)Check the condition wire breaded / nonbreaded hoses of engine. 3 II)In addition to above the following checks will be carriedout by contractor in six monthly :-(a) Replace the fuel filter and oil filter.(b) Clean the crank case breather.(c)Check the radiator hoses.(III)In addition to above the following checks will be carriedout by contractor annually :- (a)Greasing of Alternator Bearing(b)Cleaning the diesel tank.(c)Check the installation.(d)Checking of exhaust back pressure.(e)Checking of temperature of exhaust.(f)Check the performance of radiator. 4 (IV)Unit rates quoted shall be inclusive of the following : (a)Checking of all rotary and stationery parts of engine and adjust/repair the defects as required for satisfactory running of DG set.(b)Cleaning and refitting the air cleaner.(c)Cleaning of fuel filter assembly and replacement of filter element along with rubber O ring.(d)Replacement of V belt for driving radiator fan/ waterPump/Battery charger alternatorwith proper adjustment. Repair to nozzle by replacement plunger & spring valves. Replacement of high pressure stainless steel tubing not less than 1 m length from FIP to nozzle including Benjoo bolts, copper washer etc. Replacement of upper gasket kit.(e)Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure.(f)Drain out the lub oil and refill new oil after proper cleaning.(g) Checking and adjustment of tappet clearance.Note :- (i) In case of any breakdown service engineer shall attend the break down immediately and make the DG Set Serviceable within 24 working hrs. (ii)Repair, if any must be carried byContractor through authorisedworkshop of original manufacturer and Payment will be made to the contractor on Produce of Original Manufacturers Bills/vouchers. 5 All as per item No -1 here-in-before but for 125 KVA DG Sets 6 All as per itemNo -1 here-in-before but for 82.5 KVA DG Sets 7 All as per itemNo -1 here-in-before but for 62.5 KVA DG Set 8 Draining out the old sludge oil from the DG set andreplace with new oil as recommended by Mfg. complete all as directed . NOTE : Draining out of Oil shall be done twice in year each time refiling/Top up ) 9 Supply and fixing for Industrial Batteryof 12 Volt,180 AH capacity suitable for 82.5 to 250 KVA DG Sets heavy duty, 25 plates including removing existing unserviceable battery from existing places and cleaning of battery terminals and clamps properly and refixed and reconnected complete all as directed 10 Servicing of AMF Panel suitable for 62.5 KVA DG Set to 250 KVA DG Setincluding cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs allas directed NOTE :- Spare parts shall be measured and paid separately in respective item of thisschedule if required. 11 Supply onlyfor LED type Indicator indication lamps R,Y,B) complete all as directed 12 Supply only for Push Buttons start on off switch with element complete all as directed byMake : L&T or Telemechanic or equivalent 13 Supply onlyfor Control relay 9/11 pin 12 /24 volt DC of suitable for 62.5 KVA to 125 KVA DG Set complete all as directed . 14 Supply only for Digital ammeter with built in selector switch complete all as directed 15 Supply only for CT of ratio upto 150 / 5 10 VA burdan complete all as directed 16 Supply onlyfor HRC fuse 200 Amp complete all as directed . Make : L&T/SEIMENS or equivalent 17 Supply onlyfor PVC insulated & unsheathed signal core multi stranded copper cable of size 4 sq mm for control wiring complete all as directed 18 Supply onlyfor PVC insulated & unsheathed signal core multi stranded copper cable of size 2.5 sq mm for control wiring complete all as directed . 19 Supply onlyforPVC insulated & unsheathed signal core multi stranded copper cable of size 1.5 sq mm for control wiring complete all as directed . 20 Material and Labour in repairs of Temperature gauge complete all as directed 21 Supply onlyfor Oil Pressure Gauge 0-10 Bar complete all as directed 22 Supply onlyfor Digital Frequency meter complete all as directed . 23 Supply onlyfor DC Volt meter 0 to 20 volt complete all as directed 24 Supply onlyfor DC Ammeter 0 to 20 Amp complete all as directed . 25 Supply onlyfor Excitation coil for 250 KVA DG set complete all as directed . 26 Supply onlyfor AVR card for 125 KVA DG set complete all as directed . 27 Supply onlyfor AVR card for 82.5 KVA DG set complete all as directed . 28 Supply onlyfor AVR card for 62.5 KVA DG set complete all as directed . 29 Material and Labour for servicing of Turbo charger including Replacement of Turbo charger kit for capacity 250KVA /125 KVA/82.5KVA/62.5KVA complete all as directed . 30 Material and Labour in Servicing of Self Starter 24 Volt DC for 250 KVADG Set, dismantlingcomplete,& replacement of solenoid field coils. cleaning the commutator strips includingreplacing the bearing, bends pinion re-assembling, connecting and testing complete all as directed . 31 All as per item No 27 here-in- before but for capacity 125 KVA DG set complete all as directed . 32 All as per item No 27 here-in- before but for capacity 82.5 to 62.5KVA DG set complete all as directed . 33 Material and Labour for replacement of u/s contactor 415 V AC supply 4 pole suitable for 250 KVA DG Set including all accessories complete all as directed . 34 Material and Labour for in repairs ofFeed Pump for Aquatic DG set for capacity 62.5 to 82.5 KVA complete all as directed . Make -Kirloskar or equivalent 35 Dis-connecting the alternator from the engine of capacity 250 KVAby removing the coupling & outgoing cable transporting the alternator to authorized maintenance service centre for repairs Cleaning the armature, applying one coat of varnish and heating and assembling the alternator at workshop and testing at NO load, transporting the same to the site , re-connecting the alternator to the engineafter proper alignment including testing and commissioning complete all as directed . 36 All as per item No 32 here-in- before butfor 125/ 82.5KVA DG Sets complete all as directed . 37 Draining out the Water from engine of capacity 250KVAthe radiator , dis-mantling the leakingradiator assemblyfrom the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing theleaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leakages, transporting the same to the site and re-fixingand testing complete 38 All as per item No 34 here-in- before butfor 125 / 82.5KVA DG Set complete all as directed . 39 Material and Labour in taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zinc primer for out side silencer pipe & providing self adjective Asbestos Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of synthetic enamelled paint for expose partition of exhaust complete all as directed 40 Material and Labour scraping the peeled paint of DG set,preparing the surfaces, cleaning the dust anddirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint of approvedshade and writing of MES/SM No on the set all as directed of capacity 250/125/82.5/62.5 KVA complete all as directed.. 41 Supply only solenoid Switch 12 Volt DC complete all as directed . Make: Kirloskar or equivalent 42 Supply only Battery terminalHeavy duty made of brass with nut and bolt including washers suitable for 12 volt DCbattery complete all as directed. 43 Supply only Radiator Hose pipe as per existing set for 62.4/82.5 KVA complete all as directed 44 Supply only Door hinges assembly for Aquatic DG set complete all as directed 45 Supply only Heavy dutyAutomatic electronic battery charger suitable for 12/24 Volt DC complete all as directed . 46 Supply only Ignition Switch for capacityup to 250,125,82.5 KVA DG set complete all as directed . 47 Supply only solenoid Switch 24 Volt DC for 125/250 KVA DG Set as per existing complete all as directed. 48 Supply only Coolant premix as manufacture recommendations and required for top up for Acoustic DG set complete all as directed . 49 Supply only refilling of distilled water for top up battery 12 volt DC complete all as directed 50 Supply onlyAir Filterinside & out side for capacity250 KVA DG Set complete all as directed 51 Supply only Primary Fuel Filter for capacity 250KVA DG set complete all as directed 52 Supply only Secondary Fuel Filter for capacity250 KVA DG set complete all as directed 53 Supply only Lubricating Oil Filter for capacity250 KVA DG set complete all as directed 54 Supply only Fuel pipes with benjo bolt and washers. For capacity250 KVA DGset complete all as directed . 55 Supply onlyV- Belt as per existing size for capacity 250 KV DGset complete all as directed 56 Supply only Air Filterinside & out side for capacity up to 125 KVA DGset complete all as directed . 57 Supply only Primary Fuel Filter for capacity up to 125 KVA DGset complete all as directed . 58 Supply only Lubricating Oil Filter for capacity up to 125 KVA DGset complete all as directed 59 Supply only Primary Fuel Filter for capacity for 62.5/82.5 KVA DG set complete all as directed 60 Supply only Secondary fuel filter for capacity for 62.5/82.5 KVA DGset complete all as directed . 61 Supply only lubricating Oil Filter for capacity 62.5/82.5 KVA DGset complete all as directed 62 Supply only super by pass oil filter for 125 KVA DGset complete all as directed 63 Supply only Fuel pipes for capacity up to 125 KVA DGset complete all as directed 64 Supply only Vee Belt as per existing size for capacity up to 125 KVA DGset complete all as directed 65 Supply only fuel governing controller for 250 KVA DG set complete all as directed 66 Supply only Coolant hose set suitable for 250 KVA DG set complete all as directed 67 Supply only Coolant hose set suitable for 125 KVADG set complete all as directed 68 Supply only Coolant hose set suitable for 82.5 KVA DG set complete all as directed 69 Supply only Coolant hose set suitable for 62.5 KVA DG set complete all as directed 70 Supply only Fuel hose set suitable for 250 KVA DG set complete all as directed 71 Supply only Fuel hose set suitable for 82.5 KVA DG set complete all as directed 72 Supply only Fuel hose set suitable for 62.5 KVA DG set complete all as directed 73 Dismantling existing defective earthing PCC chamber and RCC cover and providing new PCC chamber in PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) and precast RCC 1:2:4 type B-1 cover, 60mm thick reinforced with 8mm tor steel bars@ 75 mm c/c both ways, with MS 12 mm dia bar lifting handle complete all as specified and directed. 74 M&L in repairsfor Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 4 mm GI Wire complete all as specified and directed . 75 Taking down old GI strip/Copper Strip ofany type and size complete allspecified and directed. 76 M&Lfor Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32x6mmGI Strip complete all as specified and directed . 77 M&Lfor Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x3 mm Aluminium Strip complete all as specified and directed . 78 M&Lfor Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32 x 6mmcopper Strip complete all as specified and directed . 79 M&Lfor Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 20 x 3 mm Copper Strip complete all as specified and directed . 80 Taking down steel tubing of any grade and size, laid under ground or fixed on wall/floor etc complete all as specified and directed. 81 M&L for GI tubing, Medium grade, fixed on wall/pole/floor/ceiling of the following sizes complete all as specified and directed:- 82 (a) 25 mm bore 83 (b) 20 mm bore 84 (c) 15mm bore 85 Supply and fix in repairs Test point terminal block made up of gunmetal or phosphorus bronze 75mmx75mmx25mm drilled and screws including 8mm dia 25mm long hex head screws and connecting to earth strip complete all as specified and directed 86 S&F in Replacement of25 mm bore gun - metalglove or gate Valves,with iron Wheel head,Screwed both ends for iron pipe and fixed for GI pipe including taking out unserviceable gate valve from existing pipe line complete all as specified and directed. 87 M & L Chemical earthing with copper pipe electrode 3 mtr long having outer dia 80 mm inner pipe dia 50 mm duly filled with highly conductive and anticorrosive compound of required quantity having chemical composition Bentonite 40%, Copper sulphate 10%, Gypsum 5% Graphite 10%, Alum 5% Zink sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 50 mm dia surrounded by soil friendly back fill compound not soluble in water including connection with galvanized earth strip 32x6 mm, making PCC pit of size 0.3 mtr x 0.3 mtr x 0.3 mtr (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia Bar and testing on completion to achieve value not more than 0.5 om complete. (Note – GI strip size 32 x 6 mm is up to 7.5 mtr length included in the item). 88 M & L forEarth recharger/Earth resistance reducing compound of 6 KG perbuckets comprising of ion and catalyser for reduction of earth resistance as well as retaining moisture in the earth pit with certified( ERDA, NABL, ROHS, IS3043, IEEE IS RULES) and without corroding the earth pit material suitable for all type of earth pit all as specified and as directed.Note-(a) Percentage reduction of earth resistance should be min 70 Percentage (b) Earth resistance value should be retain at least 1.5 years.(c) contractor will submit earth resistance value before and after utilization of material. 89 M&L for Brazing of copper strip joints for copper strips of any size complete all as specified and as directed at site. 90 Supply and fix in repairs for the following items to be incorporated in repairs to earthings 91 (a) Charcoal 92 (b) Common Salt 93 (c )Funnel with wire Mesh 94 M&L for testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete all as directed at site.Note:1. Earthings within the station premises shall be checked for proper functioning subject to a period ofat least once a month or in case of poor earth value intimated by user, whichever earlier.2. Materials and earth work for renovation of earthing shall be measured and paid separately under respective item of Sch A4. Rates quoted shall be deemed to include the cost of brazing / fixing of earth strip upto test terminal as required at site. 95 Supply and fix in repairs Test point Air termination, single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and directed . 96 Supply and fix in repairs Test point Air termination, single pointed, Aluminium Rod 12 mm dia and 300 mm long complete all as specified and directed . 97 Supply and fix in repairs to following items to be incorporated in repairs tolightening protection system under trench/ground/floor complete all as specified and directed . 98 (a) GI pipe 15 mm dia medium grade 99 (b) GI pipe 40 mm dia light grade for earth lead protection pipe 100 (c) GI pipe 15 mm dia for light grade earth lead protection pipe 101 (d)GI Pipe 40 mm dia medium grade 3 Mtr long for support to Air Termination including necessary Stay wire 10 mm dia with one side dead plug drilled with hole of 12 mm dia complete all as specified and directed 102 (e)Porcelain insulator with nut bolt and washer suitable for fixing copper/gi/aluminium strip on wall or ceiling 103 (f) Epoxy insulator 100 mm dia conical shape 104 M&L for PCC 1 : 3 : 6type C1 with 20 mm stone aggregate for foundation /concrete blocks / earthing chamber / chamber coverset in cement mortar 1:4 complete all as directed 105 Supply and fix sheet steel enclosure for test terminal block of size 150x150 mm made out of 2 mm thick dully Powder Coated CRCA sheetfor fixing test terminal blockall as directed 106 Testing of earth resistance of the existing earthing by using earth tester obtaining required test result and submit the reportall as specified and directedNote : Earth tester required for testing of resistance shall be included in quoted rates. 107 M&L in repairsfire alarm system conventional4 zone FAP control panel complyingcomplete 108 M&L in repairsfire alarm system conventional16 zone FAP control panel complyingcomplete 109 M&L in repairs MCPconventional ABS complete 110 M&L in repairs Electronic Hooter 24 Volts DC complete 111 M&L in repairs optical smoke detector complete 112 Supply andfixing PVC insulated heavy duty armoured copper conductor ofsize 2x1.5 sqmm cable for fire alarm complete all as specified and directed
Contract Date: Dec 31, 2025 Contract Value : 7.57 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
47.
Defence #8528477 AOC
Tender For Repair/ Replacement Of Dg Set, Battery Bank, High Mast Lights And Allied Works At Dhana Mil Stn.; 1 Material & labour for Maintenance and servicing of DG setof capacity 140 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 2 Material & labour for Maintenance and servicing of DG setof capacity 160 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 3 Material & labour for Maintenance and servicing of DG setof capacity 30 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 4 Material & labour for preparation of old steel surface by cleaning , stopping and rubbing down and applying two coat of synthetic enamel spray painting on old painted steel surface of existing colour including cabin (inside & outside ) of any type of DG set all as diected and specified by Engr -In-charge. 5 Material & labour for repairing of battery charger , 6-72 volts capacity by replacing Amp meter, volt meter, selector swtich, complete wiring , transformer etc including painting all as directed and directed. 6 Material & labour Engine oil 15W 40 of approved make as approved by EIC Complete all as directed. 7 Material & labour for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant,carring out pressure test and rectifying leakage by brazing/soldering test and reinstalling including topup/filling fresh coolant as on required basis all as directed and specified for DG set upto 160 KVA capacity. 8 Dismantling ofunserviceable self starter 12 volts of DG Set of capacity 160/140/30 KVA including replacment of worn out parts like bendex, piston, bush housing etc including refixing and testing complete all as specified and directed by Engr -In-charge. 9 Dismantling ofunserviceable dynamo/alternator of DG Set of capacity 140 KVA including replacment of worn out parts like carbon bushes,solenoid switch bearing, armature etc including refixing and testing complete all as specified and directed by Engr -In-charge. 10 Supply only distilled water in sealed bottle of one liter capacity complete all as specified and directed. 11 Dismantling existing inside roof sheet with insulation of DG set capacity up to 140 KVA including repair of sheet with suitable insulation complete all as specified as directed. 12 Material & labour for Earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized steel strip of size 25X4mm including 40 mm dia light grade protection,pipe 20mm dia watering pipe with funnel,CI hinged cover,PCC chamberand excavation and earth work complete all as described and shown in EP plate No 3 of SSR part I 2009 print and testing on completion all as specified and directed. 13 Supply and fix in repairs battery terminal made out of brass/bronze heavy duty suitable for 92 AH/180 AH 12 Volt Battery complete all as specified and directed. 14 Supply only Grease Multipurpose to increase equipment/ bearing life, Excellent resistance to throw off & water wash, Maximum protection offered against rust & corrosion complete all as specified and directed. 15 Comprehensive maintenance and Repair/servicing of APFC Panel of follwoingcapacity for maintaining Power factor including by replacing theconnected items etc installed for water supply installationNote : Capacitor, Contactor, MCB will be measured and paid separately.(a)90 KVAR APFC Panel at Bannad Pump House 16 (b)60 KVAR APFC Panel at Filter Pump House 17 Comprehensive maintenance and Repair/servicing of APFC Panel of follwoingcapacity for maintaining Power factor including by replacing theconnected items etc installed for Inf Bn Phase II transformersNote : Capacitor, Contactor, MCB will be measured and paid separately.(a)60 KVAR APFC Panel at 12 Maratha LI officer Mess 18 (b)60 KVAR APFC Panel at Inf Bn PH-II Area 19 Taking down unserviceable capacitor andSupply and fix in replacement cylindrical capacitor metalized poly propylene heavy duty ( MPP - H ) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 1 KVAR capacity complete all as specified and directed. 20 All as per item No 19 above but2 KVAR capacity. Make- Neptune, L&T, Epcos 21 All as per item No 19 above but3 KVAR capacity. Make- Neptune, L&T, Epcos 22 All as per item No 19 above but6.5 KVAR capacity. Make- Neptune, L&T, Epcos 23 All as per item No 19 above but 10 KVAR capacity. Make- Neptune, L&T, Epcos 24 All as per item No 19 above but 12.5 KVAR capacity. Make- Neptune, L&T, Epcos 25 All as per item No19 above but25 KVAR capacity. Make- Neptune, L&T, Epcos 26 Supply and fixing in repair 3 pole contactor for capacitor switching 30 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA30-30-10RA of ABB or equivalent in L&T, Schneider 27 Supply and fixing in repair 3 pole contactor for capacitor switching 12.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA16-30-10RA of ABB or equivalent in L&T, Schneider 28 Supply and fixing in repair 3 pole contactor for capacitor switching 7.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA9-30-10RA of ABB or equivalent in L&T, Schneider 29 Painting to existing APFC /LT panel board only one coat of synthetic enamel paint over a coat of red oxide primer after scraping, cleaning of old surface of electricpanel complete all as specified and directed. 30 Taking down unserviceable volt meter and supply and fix digital volt meter range up to 500 Volt complete all as specified and directed. 31 Taking down unserviceable Amp meter and supply and fix digital Amp meter range up to 300 Amp complete all as specified and directed. 32 Taking down unserviceable lamp indicator RYBand supply and fix led lamp indicator RYB complete all as specified and directed. 33 Comprehensive maintenance and Repair/servicing of two zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed. 34 Comprehensive maintenance and Repair/servicing of six zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed. 35 Material & labour for repair/servicing of two zone fire alarm control panel, 230V, AC, 50Hz including replacement of following connected unserviceable items:- (a) Battery with Charger (b) Faulty LED indicator (c) Reset/silence switch (d) Relay and complete all as specified and directed by Engr-in-charge. 36 Supply and fix smoke detector complete all as specified and directed. 37 Supply and fixing in replacement MCCB 4 pole 36 KA 400 A suitable for Adjustable type setting complete as specifed and directed. 38 All as per item No 37 above but capacity 250 A. 39 All as per item No 37 above but capacity 350 A. 40 Supply and fix bus bar chamber weather proof boxes made out of 3mm thick CRCS sheet front opening double chamber type for providing four numbers aluminium bus bar strips of 400 Amps and 300 mm long each, insulators, nuts bolts and MCCB 250 amps 4 pole 35 KA incoming including terminating the existing incoming and outgoing cables etc alongwith painting with 2 coats of synthetic enamal paint over a coat of red oxide primer complete with proper fixing arrangements of ground with angle iron supports duly grouted on floor/ground all as specified and as directed. 41 Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 42 Disconnecting and dismantling existing unserviceable Air termination rod and supplying & fixing new single pointed copper rod 12mm dia, 300mm long with all connections with bolts and nuts complete all as specified and as directed. 43 NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 10100.00 /- ]
Contract Date: Dec 27, 2025 Contract Value : 5.97 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
48.
Defence #8526857 AOC
Tender For Provision Of Air Conditioning System At Af Stn Agra.; 1 SCHEDULE A PART IA (BUILDING WORKS) 2 M&L for Design and Construction of AC plant room (framed structure, single storey) on permanent specifications (Approx Plinth Area 71 Sqm) including earthwork, ATT and roof treatment all as specified and directed.Note-(i)The design and drawings of AC plant room shall carried out by the contractor from approved IIT/NIT/Govt Engineering College and submitted for approval of Accepting officer before commencement of work (ii)The plinth area (Approx 71 Sqm) indicated in line plan is tentativelyminimum requirement. However, the actual size of AC plant room may increase to suit the requirement of AC plant under Sch A part-III as per OEM instructions, to be designed and installed by the contractor under ibid Scedule.Design and drawings for AC plant room shall be carried out for actual Area required as per OEM instructions for AC plant under Sch A Par-IIIor 71 Sqm which ever is more. (iii)The work shall be carried out as per approved design and drawings read in conjunction with the specifications given in tender. and as per established standard enginnering practice.(iv)The quoted rates for this item shall be deemed to include above aspects and nothing extra on account of increase in area shall be admissible. 3 SCHEDULE A PART IB (BUILDING WORKS (ADDN/ALTN) 4 Lump sum price worked out by the contractor for BUILDING WORKS/FALSE CEILING as listed in Sch A Part -IB 5 SCHEDULE A PART IIA (INTERNAL ELECTRIFICATION) 6 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch A Part -II A 7 SCHEDULE A PART IIB (INTERNAL ELECTRIFICATION) 8 M&L For taking down the flameproof LED Flood light of 250 watt from wall/ceiling and Re-Fixing the same at desired height on wall with extending the Point wiring upto 5mtr with ERW steel conduit, flexible steel conduit upto light fitting as a fire retardant and all as specified and directed 9 S&F flame proof weather proof lighting distribution pannel TPN 4 WAY Enclosure size: 420x420x250mm ,IncludingIncoming MCCB, 4P,63A-1 N0,16KA, OUTGOING MCB,1P ,32 to 63 A12nos suitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone with complete internal bus bar & wiring upto terminals aggregate complete all as specified & directed. 10 SCHEDULE A PART III (AIR CONDITIONING) 11 Supply,design,installation,testing & commissioning of not less then 44 TR water cooled scroll chiller (2 working + 1 standby) including condensor & hot water pump,cooling tower ,hot water genrator,AHU,humidifier,control panel,GI ducting, insulations & air distribution complete all as specified with all specified and directed the following:-Notes(i) The rate shall be inclusive of Designing of Complete AC plant with compentent. contractor shall submit the detailed Design &complete working drawing of AC plant including heat load calculationa, plant layout, Air distribution network layout, electrical panel details dully vetted byIIT / NIT(Relevant department).Certificate of sound design shall be on official letter pad of IIT / NIT. Complete set of design of drawing shall be submitted forapproval of Accepting Officer within 01 Months from date of commencement of work as per Work order No. 1 . In case of requirement of TR or near by capacity available in market more than specified in tender,no extra payment shall be made (Plants to be design for overall capacity 2 working & 1 stand by).(ii) The completion of the work shall be issued in phased manner. Provisional completion of the work shall be issuedAfter physical execution of the work at site complete in all respect/ phase I test as specified.(iii) ThePhase -II ( summer / mansoon / winter ) Tests shall be carried out by Sr IEM HQ CE (AF) Prayagraj Zone / Rep of Accepting Officer. (iv) TheDefect liability period of the contract shall be start as per condition 46 of IAFW 2249 General condition of contract (24 Months afterthe provisional completion of work under phase-I).(v) Data sheet of requirment of tempracture, humiditi and other required as per data sheet enclosed in PS. 12 WATER-COOLED SCROLL TYPE CHILLER UNIT (2W + 1S)Design , Supply, Installation, Testing & Commissioning of water cooled scroll chiller units having minimumcapacity not less than 44 TR water cooled Inverter scroll Chilling Machines fitted with hermetically sealed compressors, multi circuit Dx chiller,water cooled S&T condenser, Microprocessor based control panel,suitable for R-407 C or any other non-CFC/ non-HCFC gas Refrigerant, Shell & Tube Insulated Evaporator, Expansion Device, suitable capacity control mechanism actual Cooling capacity on following Operation Parametres min 3 star rating chilling units Complete as per specifications and design data mentioned in Annexure - A and detailed layout planof building to be air conditioned (Make : BLUE STAR / DAIKIN / CARRIER)SPECIFICATIONSMode of operation: Auto/ManualSingle Phasing ProtectionCompressor Restart Protection10- Sec Time Delay between SystemShort Circuit Protection 5 deg C - Anti Freeze ProtectionDisplay on Micro control indicating compressor on, Crankcase Heater ON/OffEntering / Leaving water Temp with digital identificationRefrigerant: R-407C or any other non-CFC/ non-HCFC gas, Actual capacity as per Ambient conditionScroll Chiller Unit shall be suitable for 415 V + 10%, 50 HZ , 3 Phase Ac Supply.Chilled water Inlet Temp. 12.17˚ C ,Chilled water outlet Temp. 6.67˚CFouling Factor: 0.0001 MKSCondenser water Inlet Temp. 36.2 ˚C Condenser water outlet Temp. 32.4˚CMaximum allowable IKW/TR @100% load : 1.55 13 Scope of Supply.Scope ofcompressor hermetic with assesries for (2W + 1 S) - 1 Set(i) 1set.- Scrollcompressor hermetic complete with suitable capacity squirell cage induction motor with class F insulation suitable for operation on 415 + 10% volts Inputs, 50Hz, A.C. supply andautomatic capacity control, safety switches, forced feed lubrication system etc. as per OEM specifications.(ii) 1No. Close transition type automatic star-delta starter suitable for compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventors etc. complete as required.(iii) 01 Set - Lubrication device consisting of automatic electric oil pump, oil cooler,oil strainer,automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per OEM specifications.(iv) 01 Set. - Matching Water Cooled condenser having Copper tube with Mechanically bonded aluminium fins.(v) 01No. - Matching DX type chiller for Chiller units (vi) 01 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and expansion valve.(vii) 01 Set- Microprocessor based control panel complete with all safeties, controls and LCD display as per OEM specifications.(viii) 01 Lot- Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications.(ix) 01 Lot- Water flow switches at inlet and outlet of chiller. Water drain and air purge valves whenever required. 14 Scope of SupplyScope ofcompressor hermetic with assesries for (2W + 1 S) - 1 Set(x )01 Lot- Suction line and chiller insulation with minimum 19mm thick polyvinyl nitril rubber insulation complete as required.(xi) Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti vibration pads/springsas per OEM specifications(xii)Initial / first charge of refrigerant gas and compressor oil.(xiii) 1 No. Chilled water flow Switch of suitable size and capacity (xiv) PCC cement concrete foundation for the Chiller unitas per OEM specificationsNote : - Complete Chiller system shall comprises of not less than 44 TR capacity ( 02Nos. Working Each 22 TR) + 01 Standby 50% capacity of chiller unit 15 Chilled Water Pump Set (1W + 1S)Supply, installation, testing & commissioning of centrifugal pump sets factory assembled & tested for rated efficiency complete with TEFC motor mounted oncommon base frame, coupling guard,etc. for re-circulation of condensed waterfrom cooling tower to condenserfor the air conditioning system ( CONDENSER WATER PUMPSET ). The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply all as specified and directed by Engineer-in-charge. ( 01 NOS WORKING + 01 NO- STANDBY)The Min pump characteristic of centrifugal pump set shall be as follows:a. Water quantitymin 100US GPMb. Static Head 30 Mc. ImpellerBronze(i) 1 No.- mono block type pump(ii)1 No. - Suitable HP TEFC squirell cage EE4 induction motor with class F insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply.(iii) 2 Nos. -100 mm dia dial type pressure gauges.(iv) Lot- Mounting frame with Anti vibration pads.(v) Lot-PCC cement concrete foundation for the pump unitNote: Plant shall be design for overall capacity for 1 working & 1 standby---Each of 100% capacity. 16 Condenser Water Pump Set (1W + 1S)Supply, installation, testing & commissioning of centrifugal pump sets factory assembled & tested for rated efficiency complete with TEFC motor mounted oncommon base frame, coupling guard,etc. for re-circulation of condensed waterfrom cooling tower to condenserfor the air conditioning system ( CONDENSER WATER PUMPSET ). The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply all as specified and directed by Engineer-in-charge. ( 01 NOS WORKING + 01 NO- STANDBY)The Min pump characteristic of centrifugal pump set shall be as follows:a. Water quantitymin 100US GPMb. Static Head 40 Mc. ImpellerBronze(i) 1 No.- mono block type pump(ii)1 No. - Suitable HP TEFC squirell cage EE4 induction motor with class F insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply.(iii) 2 Nos. -100 mm dia dial type pressure gauges.(iv) Lot- Mounting frame with Anti vibration pads.(v) Lot-PCC cement concrete foundation for the pump unitNote: Plant shall be design for overall capacity for 1 working & 1 standby---Each of 100% capacity. 17 Hot Water Pump SetSupply, installation, testing & commissioning of centrifugal pump sets, factory assembled & tested for rated efficiency complete with motor & common base frame, coupling guard,aluminium cladded insulation etc. for re-circulationof chilled water for the air conditioning system ( HOT WATER GENERATOR ) . The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply complete all as specified and directed by Engineer-in-charge. Make ( 01 NO WORKING + 01 NO- STANDBY)The Min pump characteristic of centrifugal pump set shall be as follows:a. Water quantity120US GPMb. Static Head 30 Mc. Impeller Bronze. (i) 1 No.- mono block type pump(ii) 1 No. - Suitable HP TEFC squirell cage EE4 induction motor with class F insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply.(iii) Lot-insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed linked XPE foam material.(iv) 2 Nos. -100 mm dia dial type pressure gauges.(v) Lot- Mounting frame with Anti vibration pads.(vi) Lot-PCC cement concrete foundation for the pump unitNote: Plant shall be design for overall capacity for 1 working & 1 standby---Each of 100% capacity. 18 AIR HANDLING UNITS- 1 NoSupply, installation, testing and commissioning of not less than 20000 CFM @ 750 Pascal total static pressure double-skin type horizontal, floor-mounted, top / side discharge air handling unit having thermal break profile complete with air-tight casing using gaskets and self-adhesive tapes 0.8 mm thick pre-coated outer skin and 0.6 mm thick GI inner skin, 45±2 mm thick double skin panel with pressure injected CFC/HCFC free PUF having k value of 0.02 W/°C/m & density 40 kg/m³, AMCA certified energy efficient plug fan(s) with backward curved impellers for high static pressure mounted on aluminium extruded side rail base frame with VFD, EU4 pre-filter and EU7 fine filter (mounted on a common frame), combination of 6/8 rows deep chilled water coil(s), suitable high efficiency (IE3) TEFC squirrel cage flame proof induction motor, PVC/nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, vibration isolators/rubber pads (minimum 1 thick) inspection windows / doors, mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers, thermostat & humidistate,etc. complete all as specified and directed by the engineer-in-charge. - 01 Nos The AHU shall comprise of the following: [a] Suitable SISW backward curved plug fan, dynamically balanced, with AMCA certified blower[b] Flame proof foot mounted (B3 construction) 3-Phase squirrel case induction motor 415 V ± 10%, 50 Hz ± 5 %, combined variation ±10%, insulation class F with temperature rise limited to class B, degree of protection IP 55, duty 51, ambient temperature 45 ºC, conforming to IS 12615: 2011, IS/IEC 60079-1: 2007, IS 3682: 1966 gas group II A, II B[c] Flexible connection made with air tight ASTM E84 (Class I) polyester fire retardant cloth riveted on periphery of cloth with extruded aluminium L angle flange as per fan size at discharge duct/plenum [d] Washable type of EU4 filter (pre-filter, efficiency 90% down to 10 micron) and EU7 filters (Micro Vee filters, efficiency 99% down to 3 micron) 19 [e]8 rows deep chilled water cooling coil section with 0.15 mm thick aluminium fins and 0.36 mm diameter copper tubes tested on 21 kg/cm²,with SS sandwiched drain tray, etc.(350 mm service section between eliminator and heater is required).[f]8 rows deep hot water cooling coil section with 0.15 mm thick aluminium fins and 0.36 mm diameter copper tubes tested on 21 kg/cm²,with SS sandwiched drain tray, etc.(350 mm service section between eliminator and heater is required) [g] Condensate drain pan fabricated from 18 gauge SS 304, powder coated and insulated with elastomeric insulation of suitable thickness[h] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated in compartmentalized construction with incoming and outgoing feeders for AHU motor, valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring, etc.[j] Variable Frequency Drive (VFD) with IP 55 enclosures and mains disconnect switch and comprising of the following complete with accessories of Danfoss, Schneider, L & T, ABB or Fuji make.(k) Built in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the Variable Frequency Drive.(ii) Built in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800:3 (un restricted distribution) :2004 Category C 1 (50 meter). (iii) Three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of the AHUs or pumps. (iv) Integral graphical keypad. NOTES:- [i] The rate of VFD and other necessary control equipment is deemed included in the quoted rate. [ii] Necessary civil work i.e PCC, RCC excavation, returning filling etc as per OEM recommandation shall be included in the quoted rate for placing of AHU and mounting of variable frequency drive (VFD) panel, construction of opening(s) for fresh/exhaust air etc. shall be covered in the scope of work. 20 Electric Hot Water Generator - 1 SetSupply, installation, Testing & Commissioning ofElectrically operated HOT WATER GENERATOR (1 Set) of capacity not less than 30KW made up of 8 mm MS sheet and dishend made of 10 mm MS sheet stainless steel lining with heaters arranged in banks and auto controller and Thermostat so that required quantity of hot water is generated at 50degree Celcius with nominal variation including 100 mm thick resinbond fiber glass insulation of 24 kg/CUM density finished with 1.25 mm thick aluminium sheet cladding including necessary electrical control panel with automatic control panel. HWG shall be provided with inlet and outlet water connections complete with pressure release valve, low level cutout, Auto-vent sight -glass all as per specifications as required at site. The HWG shall confirms to protection IP-52 with IS 2147 includign installation of automatic RH controller to achieve design condition automatically. 21 Humidifier - 1 NoSupply, installation, testing and commissioning of floor mounted ultra sonic (Mist) Humidifier capacitynot less than 60 LPH (1 No) made out of 1.5 mm thick stainless steel sheet 304 grade water storage tank, wall mounted electrical panel constructed in 18 gauge CRC sheet including control wiring from panel to Humidifier, SMPS based power supply, contactor, MCB, Relay card, connectors, on/off switch with indication, auto drain system, Humidity controller for auto/mannual operation of humidifier, control wiring with suitable sensor from ducts outlet complete all as per OEM instruction. 22 COOLING TOWER - 1 NoSupply, Installation, testing and commissioning of FRP cooling tower 01 nos of not less than 70 TR heat rejection capacity with FRP water basin PVC fillings with CTI manufacturer integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up quick filling arrangement, over flow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling lower interior, installed on MS girders (MS-I sections) fixed in masonry foundations with cement concrete footing, second class brick work and cement mortor1:6; all accessories, basin fittings, fan, fan motor suitable for 415 Volt supporting structure, anti vibration mountings etc. complete and with following technical data. (a) Water flow/tower480 USGPM(b) Ent. Water Temp.97 °F(c) Basin water Temp. 90 ˚F 23 MOTOR CONTROL PANEL FOR AC PLANTSupply, fixing, testing and commissioning factory fabricated cubicle type MV 01 no panel suitable for44 Tr or as per design capacity for comprassor motor, pumps, chiller pumps, AHU, Hot water Generator, Humidifier etc with all assesries ac plant including consisting of the 3 phase, 415volt, 35 MVA rupturing capacity made of 2 mm thick CRCA sheet powder coated conforming to IP-54, including interconnection wiring, indicating lamps etc.The cubicle panel shall be free floor standing type, complete with interlocking arrangement & earth bus. The panel shall have compartmentalized arrangement to accommodate one feeder in each compartment. A vertical cable alley of suitable width shall be provided to serve one or two vertical feeder sections. Also the openings between the busbar chamber and the feeder section shall be shrouded with Bakelite/hylam sheet with minimum 3 mm thickness. All the hardware used in fabrication of panel shall be galvanized with zinc passiveness. 24 MOTOR CONTROL PANEL FOR AHUs .Supply, fixing, testing and commissioning factory cubicle type MV 01 nos panel suitable for designed AHU consisting of the 3 phase, 415volt, 35 MVA rupturing capacity made of 2 mm thick CRCA sheet powder coated conforming to IP-54, including interconnection wiring, indicating lamps etc. 25 ELECTRICAL CABLES.S& F in ground/ in ducts/in pipes/on cable trays of following PVC insulated aluminum/copper conductor armoured cables of 1.1 KV grade confirming to IS complete with cable tray, clamps, saddles etc, including effecting proper connection to the equipment all as required with min specification of :-(i)3.5 C x 95 Sq.mm (aluminum) for Chillers & Hot Water Generator.(ii)3.5 C x 35 Sq.mm (aluminum) for main toAHU Panels and humidifiers.(iii)3C x 10 Sq.mm (alumunum) for Chilled Water , Condenser pumps, Hot water Pump, CT Fan& AHU Blowers motors.(iv) 4C x 1.5 Sq.mm (copper) For Controls.Notes:-(i) The cost includes cost of of suitable pipes for cable protection at road crossings, cable trays, protective bricks, sand and excavation.(ii) All exposed cables in trenches/wall/ceiling/roof trusses shall be provided with silicon based fire resistance coating compatible for PVC cables.(iii) All terminations shall be made with proper lugs in the approved manner. 26 Supply &fixing in possition the powder coated cable trunking of the following sizes for supporting 1100 Volts grade armoured/ unarmoured aluminium/ copper conductor cables, fabrication from angle and perforated 2mm thick M.S. CRCA sheet with expansion coupler plates duly galvanised, corner, elbow etc, with bolts, washer and nuts, knock out holes for cable connections as per approved disign, including mounting arrangment of cable tray to wall / floor with suitable size angle iron/ flat iron / pipe support. The tray shall comply with the specification of NEC (National Electric Codes) and NEMA ( National Electric Manufacturers Association) the steel shall be as per IS: 226and galvanised as per IS: 2629/BS729/ASTM 123 al as required with min specification.(a) 300 mm wide x40 mm wall height cable tray.(b) 150 mm wide x 40mm wall height cable tray.(c) 100 mm wide x 40mm wall height cable tray. 27 EARTHING M & L earthing complete with Galvanized steel earth electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth electrode not less then 1.5 Mtr below normal ground level connected to GIstrip of size 25 x 4 mm as earth lead by means of bolts, check nuts and washers of galvanized iron or steel connected to earth test point including earth strip from earth electrode to test point , GI pipe 40mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoaldust, common salt, excavation and earth work earth pit with PCC 1:3:6 type CI (using20 mm graded stone aggregate, precast RCC cover 40 mm thickness reinforced with 3 Nos TMT bars 8mm dia both ways, funnel with wire mesh, testing and rest as shown in electrical plate No-3 of SSR-I including complete all as specified and directed.Note:Earthing strip and protection pipe upto 7.5 meter length shall be deemed to be included in the quoted unit rate . Earthing strip beyond 7.5 meter shall be measured and paid separately. (Chiller unit (03), Main Control panel (04), AHU ( 02), HWG (02), Humidifer (02), Motors ( 06) : Total 19 Nos 28 M & L earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI earth lead wire 4 mm diaby means of bolts,nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work,PCC 1:3:6 type C-1 chamber with RCC cover 1:2:4 type B0 40mm thick, reinforced with 8 mm dia TMT bar, 3 Nos both way,15mm dia light grade GI protection pipe, funnel with wire mesh watering GI pipe of 20mm dia light grade and lugs including charcoal dust, common salt,and testing etc. all as shown in electrical plate No.5 of SSR Part I of 2009.- Total 04 Nos 29 PIPING-CHILLED WATER & HOT WATER SYSTEM.Supply, laying, testing and commissioning of the following nominal sizes of chilled water and hot water plumbing pipes MS ‘C’ CLASSas per IS: 1239, with necessary clamps, vibration isolators and fitting like valves, flanges, union etc. but excluding valves, strainers, gauges etc.) cut to required lengths and welded at joints and inclusive of accessories like elbows, tees, reducers, sockets etc. including insulating with 19 mm(for all pipes) and 13mm (for drain pipe) thick closed cell chemically cross linked fire retardant polyethylene foam insulation ofdensity 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered withaluminium sheet cladding 24 gauge complete with application with rubber based adhesive Pidilite SR 998 y, all as specified and repairing damage to building etc.and conforming to the specified specification,all as required on site as per manufactures design. (a) 100 mm dia Valves(b) 80 mm dia Valves (c) 65 mm dia Valves (d) 50 mm dia Valves 30 Material& Labour for PN 1.6 rated precise balancing double regulation type cast iron (CI) Balancing valve of having CI Gr. FG-200 body, EPDM / nitrile seal, stainless steel disc, ASTM A-276, Gr SS-410 stem, EPDM / nitrile bush, MS gland nut, ASTM A 276 spindle, CI bonnet, SS304 baancing nut, MS bonnet cap, CI hand wheel, MS plug, stainless steel fastener, flanged end connection, etc., and duly insulated with elastomeric thermal insulation with necessary accessories complete all as specified and directed by the engineer-in-charge.complete all as specified, offollowing sizesall as required on siteas per manufactures design. (a) 100 mm dia Valves(b) 80 mm dia Valves (c) 65 mm dia Valves 31 Supply, fixing, testing and commissioningin position of ‘Check Valves PB 16, bolted bonnet type, durable fusion bonded epoxy coated,comply with BS 5153/EN 12334, flange drilled , working pressure 16 bar including suitable flange for connection into pipe linecompledte all as specified and directedall as required on siteas per manufactures design and of following sizes all as required on site as per manufactures design. (a) 100 mm dia (b) 80 mm dia(c) 65 mm dia(d) 50 mm dia 32 Supply installation, testing & commissioning of cast steel bolted cover Y-type strainer of following sizes with CCS body conforming to ASTM A-216 Gr. WCB, AISI 304 screen with 1.2 diameter perforation, 40 kg/cm2 body test pressure & 20 kg/cm2 maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150, duly insulated complete all as required on site and directed. (a) 100 mm dia (b) 80 mm dia(c) 65 mm dia 33 Supply installation, testing & commissioning of water type PN 1.6 rated short patter CI butterfly valve having CrFG-200, CI body conforming to IS 210:2009 seat having EPDM rubber lining, CF 8 stainless steel disc. IS-410 stainless steel stem, 2.4 MPs body test pressure & 1.6 MPs seat test pressure & standard flange end conforming to BS 10 Table d/e & ANSI B 16.1 CL-125 duly insulated complete all as specified & directed by the engineer-in-charge. Teh valves shall be integral moulded design. (a) 80 mm dia Valves(b) 65 mm dia Valves (c) 50 mm dia Valves 34 Supply, fixing, testing and commissioningin position Gun metal Gate/glove Valves 32 mm dia heavy duty, butterfly handle including fixing arrnagment in MS pipe by making suitable size hole complete all as required on site and directed. 35 Material& Labour for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 20 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories all complete as required on siteand directed by the engineer-in-charge. 36 Material& Labour for CL-125 two-piece design cast iron (CI) straight pattern ball valve ofnot less than 20 mm NB, conforming to IS 9890: 1981 and having FG 200 cast iron body conforming to IS 210: 2009, AISI 410 stem, stainless steel AISI 304 ball, renewable PTFE seat & gland packing and screwed female BSP parallel threaded ends conforming to BS 21 with necessary accessories all complete as required on site and directed by the engineer-in-charge. 37 Supply & Fixing for4 bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar with necessary accessories all completerequired on siteas per manufactures design and directed by the engineer-in-charge. 38 Supply & Fixing for 6 dual scale (°F / °C), lower mount (radial), bimetal thermometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B-40.200, stem diameter 6.35 mm, laminated safety glass window, stainless steel 304 case, steam, process connection & joint, aluminium dial & pointer, IP67 protection, scale range 0- 60 °C with necessary accessories all as required on site completeand directed by the engineer-in-charge. 39 Providingandfixinginposition the water flow switches as per OEM design and specifications for the Chilled/ Hot water water circuit complete with fitttings all asrequired on site and directed. 40 Supply, installation, testing and commissioning of PN 16 rated 100 mm NB 2-way pressure independent control valve (PICV) with sensor operated flow rate or power control and energy monitoring function, flange end connections, etc. for modulating water-side control of air handling units along with valve actuator completeall as required on siteas per manufactures design and directed by the engineer-in-charge. The valve shall conform to the following technical specification:- [i] Material(a) Valve body: EN-GJL-250 (b) Flow measuring pipe: EN-GJL-250 with protective paint (c) Closing element: Stainless steel AISI 316 (d) Spindle: Stainless steel AISI 304 (e) Spindle seal: EPDM(f) Seat: PTFE, O-ring Viton (g) Imersion sleeve: Stainless steel AISI 316[ii] Electrical Data (a) Nominal Voltage: AC / DC 24 V(b) Nominal Voltage frequency: 50 Hz(c) Power consumption in operation: ≤ 7 W (d) Power consumption in rest position: ≤ 5 W[iii] Flow Measurement(a) Measuring principle: Ultrasonic volumetric flow measurement(b) Measuring accuracy flow: ±2%NOTES:- [i] The2-way Control valve shall be pre-calibrated to the given maximum flow rate.[ii] Closing off differential pressure of actuator connected with3-way diverting globe valve shall not be less than the pump head. 41 Supply,installation,testing and commissioning of proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. As per drawings and specifications. 42 Supply, fixing, testingand commissioning of condenser water pipes of MS class ‘C’of following sizes and material along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding strainer and gauges etc adequately supported on rigid supports/buried in ground including excavation & return filling etc as per specifications andall as required on site.(a) 100 mm dia(b) 80 mm dia(c) 65 mm dia 43 Supply and fixing in position 32 mm dia GI pipes medium grade cut to required lengths and installed with all screwed joints, and providing and fixing in positionincluding necessary fittings vsuch as elbows, tees, reducers etccompleteall as required on site. & directedas per specifications. 44 AIR DISTRIBUTIONSupply, fabrication installation and testing of factory fabricated GSS metal ducts 1.0 mm thick as per IS 277 (120 GSM both sides LFQ & confirming to class VIII)for GS sheets and IS-655 for fabrication of duct as per size mentioned in IS-655 according to size of duct with gauge of sheet including necessary G.I hangers/supports, volume control duct dampers, accessories vanes, 3 mm WPDM rubber gasket etc , complete all asrequired on site complete as per specification in accordance with the approved shop drawing : Thethe cost shall be inclusive of following:(i) Ducts with reinforcement/ strengthening.(ii) Air tight joints.(iii) Accessories such as splitter, damper, guide vane etc.(iv) Hangers, Fastener and supports; Rectangular duct should be support from ceiling/wall with bracket/Gripple wire/hanger etc. Selection should be as per site condition and drawing.(v) Painting with black colour paint for duct sides behind the grills.(vi) The gasket used in case for all ducts shall be fire retardant type (vii)Fire damper shall be installed in all main entry / exist of duct into Air conditioned spaceNote : Duct design shall be carried as per IS 655: 2006 & the latest edition of HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at siteas per manufactures design complete all as specified and directed by engineer-in-charge. 45 Grilles/ Diffusers.Material & Labour for square / rectangular / round neck 450 mm X 450 mm rectangular neck 4-way discharge ceiling return diffuser having neck velocity ≤ 600 ft/min, throw ≥ 19 @ 150 ft/min velocity NC ≤ 26 for air flow ≥ 1057 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereoff, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all asrequired on site as per manufactures design and directed by the Engineer-in-charge. 46 Supply, installation, testing and commissioning of high performance air foil class 1A leakage rated GI volume control damper having galvanised steel hat channel frame reinforced with corner braces, galvanised steel airfoil shaped blades (double skin construction) of 14 gauge thicknes, neoprene blade edge seals, flexible metal compressible jamb seals, stainless steel sleeve, linkage concealed in frame, etc. tested as per AMCA Standard 500-D-98 complete all asrequired on siteas per manufactures design and directed by Engineer-in-charge. 47 Fresh Air GrillesSupplying, fixing, testing and commissioning of power coated extruded aluminium section of 120 G thick for fresh air grill in weather maker room with volume control dampers, bird screen etc complete all asrequired on site as per manufactures design. 48 Material & Labour for CBRI certified 16-gauge GI fire damper ( Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.) , at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated cross overs (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 completeall asrequired on site and directed by the engineer-in-charge.The fire dampers shall meet the following criteriaon:- [i] Bare fire dampers with 400 mm sleeve [ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position [iii] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer. 49 THERMAL INSULATIONSupply, installation, test and commissioning of accoustic insulation insdie the duct with engineered nitrile rubber open cell foam with density 140-180 kg / cum and class - I fire performance and with antimicrobial as per ASTM E 21 using manufacturers recommended rubber based adhesive in a solvents complete all asrequired on siteas per manufactures design and directed. 50 Supply install test and commissioning of thermal insulation of duct with 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation ofdensity 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered withaluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously and externally wrapped with wrapped with 3M Fire Barrier Duct Wrap 615+ certified to ISO 6944 (air duct test standard) all asrequired on site as per manufactures design. 51 Material & Labour for underdeck insulation for RCC roof (on AHU Room ceiling) with bonded fibre glass wool of density 48 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and kraft paper, comprising of the following (insulating material shall conform to BS -476, Part 4,5, 6 & 7):-“(a) S & F 50 x 50 mm or 75 mm x 75 mm slotted angles 50 mm wide, fixed to the ceiling by means of rawl plug 600 mm centre to centre.“(b) Supply and draw GI tie wire 22 Gauge from vertical slots, for holding the insulating material in position with and including GI washer.“(c) S & F aluminium foil, adhesive tape 50 mm for sealing of aluminium foil flanges.“(d) Providing additional support to the insulation with and including chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction, stretched firmly over the insulation and fixed. (on AHU Room Ceiling) 52 Supply& Fixing for 25 mm black flexible closed-cell elastomeric thermal insulation (on AHU Room walls) made of elastomeric foam based on synthetic rubber (NBR / PVC), tested for maximum service temperature 100 ºC as per ASTM C-534 & minimum service temperature -50 ºC as per ASTM C-534, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 24 ºC as per ASTM C-518 / C177, ASTM C-335, water absorption by volume ≤ 0.2% as per ASTM C-209 / C-1763, flame spread index (FSI) & smoke development index (SDI) 25/50 as per ASTM E-84, flammability HB, V-0 as per UL-94, fungi resistance as per ASTM G-21/C-1338, mould growth resistance as per ASTM E-2180-18 / UL-181 and ozone resistance as per ASTM D 1149-18 laminated with 12 micron aluminium foil facing with reinforced glass scrim, adhesives and other necessary accessories completeall asrequired on siteand directed by the engineer-in-charge. (for AHU Room walls) 53 Supply & Fixing forwall mounted digital temperature cum % RH controller complete with large LCD, English display having operating voltage 240±10% V AC, 50 Hz frequency, ≤ 8 VA power consumption,0.5 ºC temperature display resolution, 0.1% relative humidity display resolution, IP20 protection, etc. including battery and control wiring in PVC conduit from thermostat / humidistat in return air duct to AHU Room complete as specified and directed by engineer-in-charge - qty 02 nos 54 Supply & Fixing forIndoor type wall mounted digital temperature cum %RH meter (Digital Thermo Hygrometer) complete with large LCD, English display having operating with 12/24H Max/Min temperature and humidity memory function range -50°C to70°C Temperature accuracy 0.5 ºC and Humidity range 10% to 99% RH Humidity accuracy 5% RH Humidity resolution 1% RH Power source 1*AAA (1.5V) battery complete as specified and directed by the engineer-in-charge.qty 02 nos 55 S &F structural rolled mild steel joist, channel, angle, tee or flat section conforming to grade Fe 410-O or Fe 310-O fixed independently, without connecting plates etc. as in nd duct supports including tie bars with screwed etc complete all asrequired on siteand directed . 56 Material& Labour for drain water pipe of 20 mm NB including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories complete all asrequired on siteand directed by the engineer-in-charge.NOTES:- [i] The pipe size 150 mm NB & below shall be MS C class as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB 57 Supply,installation,testing and commissioning of rotational moulded polyethylene expansion tank cylindrical vertical with closed top of capacity 10000 Ltrcomplete insulated with FR- XLPE/XPE 19 mm thick of minimum bulk density 28±4Kg/cum covered with vapour barrier and finished with 0.5 mm thick AI cladding and applied with Pidilite SR 998, air vent, NRV, drain connection and float valve including quick fill by installingsuitable size monoblock pump set and controller including suitable foundation as per OEM instruction complete all as specified and directed. 01 nos 58 Supply, install, commission, and test of commercial Air curtain unit for door opening size 70X96 with sensorto operating commands as per human movement for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, 2m wide with maximum noise level 40 to 60 dB, 960 rpm 8/9 m/s effective air through capacity 2.2m made out of Stainless steel sheets of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles, etc, complete with fittings and accessories. 59 S & FGI earth strip 25 mm x 4 mmbelow ground, in 40 mm GI pipe wherever required and on surface or in recess for connections etc all as required on site. 60 Earth continuity conductor or mainearthing lead fixed to wall on battenor recess or chases or buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. asrequired 4mm dia galvanised iron orsteel wireall as required on site. 61 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) 62 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch A Part -IV 63 SCHEDULE A PART VA (EXTERNAL ELECTRIC SUPPLY) 64 Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch A Part -V-A 65 SCHEDULE A PART V -B(EXTERNAL ELECTRIC SUPPLY) 66 Supply, installation testing and commissioning of 100 KVA outdoor type transformer level 3with standard fittings and accessories , step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-11 with neutral brought out seperately for earthing including off load changing tap arrangement up to +7.5% in steps of + 2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection with trunk bus bar PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height) complete all as specified and directed and conforming with IS : 1180 (Revised)Transformer shall comprises of the following:-(i) HT side (primary side) consisting of three Nos porcelain bushing with brass rods complete with nut & washers HT bushing suitable for outdoor mounting transformer 11000 volts grade.(ii) One cable box LT side (secondary side Consisting of four Nos porcelain in bushing complete with nut & washers with one No cable gland suitable for reception LT 1100 Volts grade XLPE insulated heavy duty amounted cable of suitable size complete. (iii) Oil conservator with filter type drain valve and oil level gauge complete. (iv) De-hydrating breather with first fill of dehydrating agent (silica gel). (v) Explosive vent & thermometer pocket on tank cover oil level gauge ,Oil level gauge ,oil drain filter valve lifting lugs oilfilling hold with cap/plug with connection plate complete Air release valve plug and four Nos solid cast steel detachable rollers. (vi) One 100MM dia ,dial type thermometer ,vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temprature reading indicator with re-setting device. (vii) Two earthing terminals on tank cover to facilitate fixing of 50x6MM earth strip for earthing of neutral & two for body.(viii) Rating plate and terminal making plate.(ix) Extra bushing for Neutral in the LT cable box providing independent set of earthing for neutral.(x) First filling of new & unused transformer oil as per IS-335 marked filtered and tested upto 55KV dielectric strength at 2.5MM air gap between testing electrode. (xi) The factory inspection is to be carried out by inspecting officer detailed by accepting officer. 67 Note for srl item No 11.01 : The contractor is required to submit appropriate guarantee against the manufacturing defect as offered by the manufacturer beyond one year from defect liability period also if any from the date of completion for the Transformer. Theresponsibility of the contractor does not absolvey submitting the above guarantee against the manufacturing defect. If any defect so caused within the above guarantee period whatsoever the contractor is liable to rectify the same at his own arrangement and alternative arrangement to be provided by contractor within 24 hrs, if transformer not repair immediately at site, the unit rate quoted by him is deemed to have included the above provision. 68 Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440V, 50 Hz system with incoming MCCBS for permissible non-linear load 15% of 50 (25x2) KVAR capacity all as specified and directed. 69 Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipeconnected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforcedwith 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth workreturning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. 70 Supply and fix double wall corrugated as per IS 16025 PART-24 pipe of outer dia 110/90 MM (including all connected fitting and accessories) all as specified and directed. 71 Supply and fix double wall corrogated as per IS 16025 PART-24 pipe of outer dia 160/136 MM (including all connected fitting and accessories)all as specified and directed. 72 Supply and fix double wall corrogated as per IS 16025 PART-24 pipe of outer dia 50/38 MM (including all connected fitting and accessories)all as specified and directed. 73 Supply, Install, testing & commissioning of outdoor 12 kv 630 A 21 KA for 3 sec with internal arc of 21KA for 1 sec for both tank and cable box, SF6 insulated completely motorised opertated ring main with RMU tank made of 2 mm thick stainless steel, mannual TIG/ROBOTIC welding and with front cable termination. RMU bus bar shall be of copper and RMU coupling shall be from side only.RMU as complete consisiting of with right hand side extensible 2 nos 630A VCB as incomer and 2 nos 630AVCB as outgoing with scada compatible overload and earth fault protection (dpx type protection relay), metering panel (meters for VCB feeder), capacitance voltage indication, fixed type VPIS, cable root for VCB including necessary foundaion as per manufacturer recommendation and making electrical connections complete all as directed.. 74 M & L for Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. 75 M & L for Rubber mat of size 1mtrx2mtrx19mm complete all as specified and directed. 76 Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board,250 Amp aluminium bus bar insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 50 x 5 0 x 6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate ,thimbling and cable entry boxes with cable gland. and the Aluminium bus bar should be 1.5 time from themain incoming.(a)MCCB 4 pole 160 amps 35 KA -01 NO (INCOMING)(b)MCCB 4 pole 100 amps 25 KA-01 NO(OUTGOING)(c) MCCB 4 pole 63 amps 25 KA -01 NO (OUTGOING)(d)Ampere meter (digital type)with selector switch - 01 No(e)Volt meter (digital type) 0-500 volts with selector switch - 01 No(f)Indicator lamp RYB (3 Nos) - 01 Set(g)CTs of suitable cap 77 SCHEDULE A PART VI A(DG SET) 78 Lump sum price worked out by the contractor for DG SET as listed in Sch A Part -VI 79 SCHEDULE A PART VIB(DG SET) 80 Supply and fix double wall corrogated as per IS 16025 PART-24 pipe of outer dia 63/50 mm ( including all connected fitting and accessories)all as specified and directed. 81 M&L earthing complete with galvanized steel plate electrode 60cm X60cm X6mm surrounded by charcoal & salt buried directly in a pit of depth not less than 1.5m below ground level with top edge of the earth plate at a depth of not less than 1.50m below ground level, connected to and including GI strip 32x6mm upto 7.5m length by means of bolts, nuts, check nuts & washers of galvanized iron, earth strip protected by galvanized steel pipe 40 mm bore (light grade) & connected to main control board including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore GI pipe (medium grade) for watering, funnel, wiremesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-1 cover & frame etc) including GI protecton pipe for earth lead complete all as indicated in electric plate No 3 of SSR 2009 Part I including testing complete all as specified and as directed. 7572.90EACH SET 4 30291.60 82 Supply, Commissioning, erecting & testing complete of manufacturer or OEM manufactured, static silent (sound proof enclosure) Disel Engine driven Generating set of capacity 82.5 KVA confirming to emission limits issued vide GSR 771 (E) dated 11 Dec 2013 and its amendments vide GSR 232 (E) dated 31 Mar 2014, GSR 789(E) dated 11 Nov 2014 and GSR 105(E) dated 17 feb 2015 at Ser No. 95 issued by Ministry of Environment and Forests Government of India , water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Agra (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB guidelines and comprising of followings all as specified and directed:- 83 DIESEL ENGINE : Diesel engine 1500RPM, direct injection, multi cylinders, four stroke,conforming to IS:100001 / ISO3046 / BS: 649 / BS: 5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 82.5 KVA at outdoor atmospheric conditions at Agra (Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:-(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level(v) Radiator cooling (vi)Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter with water seperator(ix) Fuel injection pump (x) Fan and water pump assesembly(xi) Lub oil filter and pump assembly(xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maintenance free lead acid battery as per manufacturer recommendationincluding inter connecting cables/leads with terminals complete.(xiii) Engine safety shut down system against lowoil pressure and high water pressure. (xiv) Exhaust gas driven turbo charge(xv) Oil filter(xvi) Lub oil cooler (xvii) Engine main manual with spare part list(xviii) Suitable designed acoustic enclosure as per CPCB IV regulations(xix) Any other item not included / specified but is a standard design of the manufacturer. 84 ALTERNATOR Alternator shall be self excited, self regulated, brush less for 82.5 KVA continous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS : 4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition.Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B-1using 20 mm graded crushed stone aggregate in foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations / instructions is deemed to be included in the unit rate quoted by the contractor. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy withfuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per moderan engineering practice complete all as specifided and directed. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy withfuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per moderan engineering practice complete all as specifided and directed. 85 Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity125 Amp is to be installed near AMF panel complete all as specified and directed.(i) Hour run meter.(ii) Any other item not included/ specified but is a standard design to the manufacturer.AMF CONTROL PANEL.Inbuilt AMF panel of suitable size including all accessories and measuring instrument as provided by OEM.ONE SET OF ACCESSORIES COMPRISING OF :-(a) Base frame of sturdy design and necessary reinforcement with built-in diesel tank as per manufacturers standard(i) Fuel tank of sheet metal complete with drain valve, air vent, inlet, outlet connections, and mechanical gauge.(ii) One No battery 12V, 1x88 AH charged with connecting leads of suitable capacity as per manufacturers standard.(iii) Fuel tank should be of draw-out/drag-out facility for easy cleanout.(iv) SMPS PSU for battery charging in case of non-running of DG set for long periods.Note for Items No 14.3:All testing arrangement including T&P & consumable items such as fuel, Oil & other connected items required will be carried out by contractor for testing as per CA specification and testing sheet given in this tender documents at no extra cost to the department. (ii)Factory testing will be carried out. (iii) Testing at factory in presence of testing officer detailed by Accepting Officer. 86 SCHEDULE A PART VII-A (SEWAGE DISPOSAL) 87 Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch A Part -VII-A 88 SCHEDULE A PART VII-B (SEWAGE DISPOSAL) 89 Construction of septic tanks including excavation in ordinary soil, fdn in PCC1:2:4, brick work in CM 1:4, RCC slab, reinforcement, including RCC manhole covers, CI vent shaft and sludge chambers etc, for 20 users complete all as specified and shown on drawings. 90 Soakage, well excavation in ordinary soil, foundation in PCC 1:3:6, wells of honey combed and solid brick work in CM , RCC slab covers, filling with brick bats, complete of size 1.20 mtr dia and 1.50 mtr deep. 91 SCHEDULE A PART VIII-A (FIRE FIGHTING) 92 Lump sum price worked out by the contractor for FIRE FIGHTING as listed in Sch A Part -VIII-A 93 SCHEDULE A PART VIII-B (FIRE FIGHTING) 94 M&L for taking out the MS pipe of 65 mm dia with connected accessories from roof/ceiling and deposited to MES Store all as specified and directed. 95 M&L for taking out the MS pipe of 25 mm dia with connected accessories from roof/ceiling and deposited to MES store all as specified and directed. 96 M&L for shifting ofFlame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module 97 Supply and laying the FRLS armoured with steel wire or strip fire alarm control cable PVC sheathed copper conductor of size 1.5 sqmm 2 core. 98 SCHEDULE A PART- I X(EARTH WORK) 99 Lump sum price worked out by the contractor for Earth Work as listed in Sch A Part -IX 100 SCHEDULE A PART- X(INTERNAL WATER SUPPLY) 101 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch A Part -X
Contract Date: Jan 01, 2026 Contract Value : 1.28 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
49.
Educational and Research Institute #8506510 AOC
Tender For Annual Repairs To Non-Residential Buildings At Savitribai Phule Pune University.(2025-26)- Removing planking from roof or ceiling and stacking them as directed with all leads and lifts etc. complete 2 Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. 3 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. 4 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. 5 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 6 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete 7 Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete 8 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. 9 Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. 10 Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete. 11 Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete 12 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 13 Removing wire fencing with iron/ C.C. fencing post and stacking the materials as directed with all leads, lifts etc. complete. 14 Removing cast iron or wrought iron or A.C. pipe and stacking them as directed with all leads, lifts etc. complete. 15 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. 16 Removing Np-2 and Np-3 class pipes including stacking at road side as directed by the Engineer in charge. Upto 900mm dia and above. etc complete 17 Removing battens from roof and stacking them as directed with all leads and lifts etc. complete. 18 Removing purlins from roof including stacking as directed with all leads , lifts etc. complete. 19 Removing rafters from roof including the materials as directed with all leads , lifts etc. complete. 20 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete 21 Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete 22 Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete 23 Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc.complete. 24 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for executionof all items for such works. 25 Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads and lifts complete. Including removing wood work below etc. complete. 26 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessary screw,making proper adjustment for smooth operation etc.complete as per sample approved by Engineer in-charge. 27 Replacement of damaged Aldrop 300mm Chromium plated of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge 28 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge 29 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 30 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 31 Filling tiles joint portion offlooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete. 32 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual Means 33 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 34 Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means 35 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stackingas directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. ((Lift upto 1.50 m) By Mechanical Means 36 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stackingas directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means 37 Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means 38 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. 39 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.complete 40 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. 41 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete 42 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC withoutSCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 43 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic microprocessor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 44 Providing and laying Cast insitu/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks,foundation block sand such other items including bailing out water,Steel centering,formwork,laying/pumping,compacting,roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc.complete.The Cement Mortar1:3 plaster is considered for rendering uneven and honeycombed surface only.Newly laid concrete shall be covered by gunny bag,plastic,tarpaulinetc.(Wooden centering will not be allowed.),with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concreteBatch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 45 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 46 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap /granite/quartzite/gneiss metal for R.C.C.work in foundations like raft,strip foundations,grillage and footings of R.C.C.column sand steel stanchions etc.columns as per detailed designs and drawing or as directed including Steel centering formwork,cover blocks laying/pumping,compaction finishing the formed surfaces with cement mortar1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc.complete.(Excluding reinforcement and structural steel).with fully automatic microprocessor based PLC with SCADA enabled reversible DrumType mixer/concrete Batch mix plant(Pan mixer)etc.complete.With fine aggregate(Crushed sand VSI Grade) 47 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 48 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC withoutSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 49 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 50 Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade 51 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 52 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for .C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 53 Providing Decorative cement concrete mould in M-25 concrete over top of column of size 450x450x300 as per drawing & design including plastering, finishing,cleaning etc. complete 54 Providing and laying insitu cement concrete M-30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20mm deep with necessary refilling with bitumen(excluding reinforcement)with coarse and fine aggregate(natural sand/ VSI grade finely washed crushed sand) etc. complete 55 Providing and laying insitu cement concrete M30 with tremix treatment for 200 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc.complete 56 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 57 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete 58 Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete 59 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. 60 Providing and fixing mild steel grill gate as per the detailed drawing including hinges,locking arrangements and painting in three coats of oil paint of approved colour and shade etc.complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.)Spec.: As directed by Engineer- in-charge. 61 Providing structural steel work in hollow section of various thickness and sizes in square,rectanular and round shape from 25mm to 450 mm section as per IS4923YST310 Grade produced from iron ore and blast furnace route etc.as per detailed designs and drawing or as directed including cutting,fabricating,hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and paintingcomplete. 62 Extra for curvature/Bending of structural members.Spec. No: - As directed by Engineer in charge 63 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement In mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 64 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complet 65 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 66 Providing fly ash brick masonry (Steam Cured)with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. 67 Providing fly ash brick masonry (Steam Cured)with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc.Complete 68 Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete 69 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. 70 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done / striking joints when no plastering is to be done on inside watering and scaffolding etc.complete. 71 Providing coursed rubble masonry first sort of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in external work of plinth including bailing out water manually, striking joints inside and watering etc.complete. 72 Providing expansion joints in R.C.C. framed structure (at terrace level) cleaning of the surface to remove dust, loose particles a) Providing and applying of Moisture insensitive epoxy putty - Sikagard 694 F(I)b)Providing and applying of Contape POE 900 with Epoxy Adhesivec)Providing and applying of Fosroc Thioflex 600 Gun Grade 73 Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed 74 Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and waterproofing compound at 2 Kilogram/bag of cement mixed in 35 liters of water including drilling holes in required position grouting with above mixed solution and ceiling etc. complete 75 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 76 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. 77 Providing internal cement plaster 6mm thick in a single coat in cement mortar1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 78 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. 79 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete 80 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete 81 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete 82 Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. 83 Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. 84 Providing fine cement finish 1.5mm thick over green plaster surface including scaffolding curing etc.complete. 85 Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. 86 Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.Spec. No.: As directed by Engineer in Charge. 87 Providing and applying laying Aggregate plaster in granite/marble stones,as decorative finish to give granite/marble like appearance to concrete,brick or block surfaces in all position including preparation of surface smoothly,evenly by racking of joints incase of Brick or block work including backing layer of 12mm thick with cement mortar1:3 with 2% integral cement waterproofing compound,roughening for wall keying hardening and drying the surface for a minimum five days gaps including second coat of cement lime mortar into a proportion1:4 preparing the surface for three coat of marble finish plaster giving a thin coat of white cement and two parts of course calcite powder,applying the mortar with steel float on the surface in proper evenness applying at coat of white cement and lime to set a smooth finish then applying a thin coat of slurry made of white cement and black oxide colour in required proportion by the steel float to get black streaks on the surface and curing thesurface for two days including al materials and labour etc. complete 88 Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. 89 Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete 90 Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. 91 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete 92 Providing Ashlar Stone Masonary ( First ) work in cement morter 1:4 with watering as shown in drawing & design with all necessary including scaffolding etc. complete.NDSR, Spec; as diretced by engineer in charge. 93 Removing and refixing existing ashlar coping in C:M 1:5 Mortor etc. completed -NDSR 94 Cleaning the external surface of walls using steripure S30 to remove algae, fungus growth, flakes of stones including double scaffolding, as directed by Engineer Incharge etc. complete. 95 Raking out joints & pointing of stone masonry /cladding filling the gap with lime mortar in proportion 1:1:5 i.e.. White cement : lime : stone dust with required qty. of water pigments to match existing sheds and texture of stone including double scaffolding, cleaning the crack or joints or as directed by Engineer Incharge etc. complete. 96 Provding and fixing the great indian Baslat stone cladding of various sizeand having thickness of 15 to 18 mm (+,-2mm with top surface hammertone effect abd back side surface calibrated effect for better grip etc. completed. including all required material for fixing with adhesive , scaffolding, labour as per details drawing and design. spec. As per directed by Engineer in-charge. 97 Providing and applying approved silicon silaxane coating to existing stone masonry façade against fungus, moss growth including double scaffolding, curing, cleaning etc. complete. 98 Providing and laying Rough Shahabad Stone Flooring 25mm to 30mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. 99 Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 100 Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. 101 Providing and laying cement concrete flooring 50mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction,fillingjoints,marking lines to give the appearance oftiles of 30cmx30cm or other size laiddiagonally/squareetc.finishing smooth(with extra cement)in any colour as directed and curing etc. complete. With Crushed Sand 102 Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 103 Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.. 104 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 105 Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 106 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 107 Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring 108 Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Skirting 109 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 110 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete 111 Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition withfull moulding the edges etc. complete . Both side polish 112 Providing and fixing 1.5 mm thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete 113 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete. 114 Providing and laying vitrified mirror / glossy finish tiles of RAK/ Kajaria/ Nitco/ Asian or equivalent make having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. b) Skirting Spec. No.: Bd.M. 12 Page No.385 115 Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make,shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. 116 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 117 Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 118 Providing and laying vitrified rustic matt stone finish tiles of RAK/ Kajaria/ Nitco/ Asian or equivalent make having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. complete. b) Skirting Spec. No.: Bd.M.12 Page No. 385 119 Providing & laying Pavit make tiles havingsize 300mm x 300 mm of15 mm thickness of approved shade & pattern for flooring in required position laid on a bed of 1:4 cement morter including neat cement float ,filling joints,curing & cleaning etc.complete. 120 Providing & lying Pavit / Johnson Endura/AGL make matt finish tiles havingsize 600mm x 600 mm of15/16 mm thickness of approved shade & pattern for floorimg in required position laid on a bed of 1:4 cement morter including neat cement float ,filling joints,curing & cleaning etc.complete. Spec. As directedby engineer in- charge 121 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete. (using 100% crushed sand) 122 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 80 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete. (using 100% crushed sand) 123 Fixing heavy duty inter locking concretePAVING BLOCKS of 60 millimeter thicknesssupplied by SPPU(using 100% crushed sand) Spec. No.: Bd. M-12 page No. 385 -Labour Rate Only 124 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherevernecessary, curing, etc. complete. 125 Machine polishing to cement/marble mosaic tiled flooring or any other type of flooring including cleaning, washing, etc. complete. 126 Providing and filling crack filling material to conealed existing crackat any location by Dr. Fixit crack filler 127 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 128 Providing and applying french polish to new wood work, for required finishing including.knotting, preparing the surfaces, scaffolding etc. complete as directed 129 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. 130 Providing and applying PU polish exterior grade of required ( Matt/Glossy) finish to the wood work by spray machine including knotting and preparing the even surface by sanding and scraping of existing polish/paint of doors & windows including frame work to get original or as directed including scaffolding & dent filling with filler over the dented area etc. complete. 131 Providing and applying 2coats of alluminium paint of approved make to new structural steel work in building sand workshops including scaffolding if necessary,cleaning and preparing the surface(excluding primer coat)etc. complete 132 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete 133 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 134 Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete. 135 Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc.complete 136 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. 137 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete 138 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete 139 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. 140 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. 141 Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area.wall primer with brush by adding mineral turpentine oil by 8to10% or water by 15to20% allowing to dry for 6to8 hours After applying acrylic wall putty with appropriate proportion of water of allow to dry for period of 4to6 hours of activity.Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40to45% or 65to70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40to45% or 65to70% by roller. 142 Providing and fixing Indian teak wood plank ceiling 20 mm thick plain underside tongued and grooved including iron screws, scaffolding, if necessary, including one primer coat on under side and one coat of coal tar on upper side etc. complete. 143 Providing and fixing Indian teak wood framed collar beam / king post / queen post truss, with all Iron work including scaffolding, if necessary, and one coat of primer etc. complete. 144 Providing and fixing country teak wood common rafters, purlins and purlin cleats, hip rafters, jack rafters, ridges, wall plates, post plates and posts for roofing etc. including scaffolding, if necessary, all iron work and one coat of primer etc. complete. 145 Providing and fixing Indian teak wood eaves boards 15 cm wide and 25 mm thick plain decorative type including scaffolding and painting with two coats etc. complete. 146 Providing and fixing country teak wood barge board 22 cm wide and 20mm thick plain type including scaffolding and painting intwo coats etc. complete. 147 Providing and fixing Mangalore tiled roofing with class AA tiles including securing the last course of tiles near the eaves with steel flat 40 mm x 3 mm and 1.22 mm wire fixing country teak wood sloping battens of 25 x 12 mm teak wood horizontal battens of 50mm x 25mm over the slopping battens, all iron work and coal tarring the battens etc. complete (Excluding ridge and hip tiles). 148 Providing and fixing Mangalore tile ridge and hip tiles of class AA including scaffolding if necessary, pointing with coloured cement mortar and curing etc. complete. 149 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). 150 Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). 151 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete. (excluding painting to underside of plank). 152 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete. (excluding painting to underside of plank). 153 Providing and fixing valley gutter of 24 B.W.G. (0.63 mm) thick G.I. sheet 120 cm wide with 20 mm thick teak wood planking underneath coal tarring etc. complete. 154 Providing and fixing false ceiling of plain asbestos cement sheets 4 mm thick with teak wood beadings 45 x 12 mm with frame work of teak wood battens of size 70 x 60 mm at 1.00 M center to center including scaffolding, if necessary, all iron work and painting (visible surfaces) to A.C. sheet and beading in two coats etc. complete. (excluding T.W. runner to be paid separately). 155 Providing and fixing false ceiling of 15mm thick as per drawings including powder coated G.I. wall angle of 20 mm x 20 mm x 0.60 mm size, G.I. grid runners of size 15 mm x 38 mm at 600 mm center to center both ways and suspended using G.I. 3 mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete 156 Providing and fixing false ceiling sheets of 15mm thick to existing GI grid with levelling including transporting, scaffolding & removing existing sheets with all necessary labour and machinery,finishing etc. complete.Spec :As directed by Engineer in charge.. 157 Providing and applying two coats of bitumen to roof on new dungaree cloth one coat on each side etc. complete as directed. 158 Providing and applying one coat of bitumen to roof (without cloth) including scaffolding etc. complete as directed. 159 Removing and resetting Mangalore tiles from roof including refixing loose battens etc.complete. 160 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 161 Providing fixing country teak wood battens 50 mm x 25 mm for Mangalore tile roof work with all iron work scaffolding and oiling the battens etc. complete. 162 Providing fixing teak wood battens 25 mm x 12 mm for Mangalore tile roof work with iron work scaffolding and oiling the battens etc. complete. 163 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm centerto-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) 164 Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 mm,comprising of nominal 25mm exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mmcenterto-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) 600 mm girth (Surface Width). 165 Providing & fixing 10mm thick poly carbonate sheets of approved shade / colourincluding ridges and flashings of 230mm wide as per drawing issued, all fixing arrangement such as screwing etc. and ensuring water tightness by applying silicon sealant in gaps ensuring 100% water tightness, Virgin PVC ,gaskets of approved make / manufacturer for roofing over open courtyard, ramp, etc. as per drawings issued (Giving guaranty for 10 years). (Rate shall Include Alluminium patti male female type at joints & edges) 166 Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texturespintone/cosmos/hexa or equivalent of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides)consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mmof all T-sections shall be prepainted with polyester baked paint, for all heights, as perspecifications, drawings etc. complete. 167 Providing and Fixing wall Soft Fibre Acoustical Suspended /Gypsum perforated sheet/techno Acoustic panels/Equivalent system with Optra (BevelledTegular)Edge Tiles of size 15mm Exposed Grid.The tiles should have Humidity Resistance(RH) of 95%,NRC0.9-1.0,Light Reflectance?85%,Colour White,Fire Performance UK Class0/Class1(BS476pt-6&7) in module size of 600x600x15mm,suitable for Green Building application,with Recycled content of 66% GW and74%RW.The tile shall be laid on precoated G.I channel 32with15mm wideT-section flanges colour white having rotary stitching on all T sections i.e.the Main Runner,1200 mm and 600mm Cross Tees with a web height of 32mm and a load carrying capacity of 7 Kilograms/M2 with aminimum pullout strength of 100Kilograms.The T Sections have a Galvanizing of 90grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty.products approved as per GRIHA and BS 476 etc. complete. 168 Providing and Fixing Mineral Fibre Acoustical Suspended Ceiling System with Dune(BevelledTegular)Edge Tiles of size15mm Exposed Grid.The tiles should have Humidity Resistance(RH)of 99%,NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 -0.057w/mK,Colour White,Fire Performance UK Class0/Class1(BS476pt-6&7)inmodule size of 600x600x16mm,with Recycled content of 35%.The tile shall be laid on precoatedG.I.channel height 32 with 15mm wide T-section flanges colour white having rotary stitching and XL2CLIP on all Tsections i.e.the Main Runner,1200mm and 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.57Kilograms/M2 and pullout stength of minimum100 Kilograms..The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system.The Tile and Grid system used together should carry a 10 year warranty.approved as per GRIHA and BS476 etc. complete 169 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed toreinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item tobe completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 170 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete 171 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 172 Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete 173 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) a) Without mechanical gear 174 b) With mechanical gear 175 Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete.(I.S. 105211983). 176 Providing and fixing partition of welded mesh of 3 mm dia. wires 50 mm x 25 mm size mesh including integrated non teak seasoned wood frame 80 x 50 mm of vertical and horizontal scantling and finishing with oil painting 3 coats etc. complete 177 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 178 Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc 179 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417Kilogram/Running metre. As per detailed drawings and as directed by Engineer in chargewith all necessary Aluminium sections fixtures and fastenings such as roller bearing in nyloncasting and self locking catch fitted in vertical section of shutter including 5 mm thick plainglass with all required screws and nuts etc, complete. With powder coating without box 180 Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm atweight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weighto.417 Kilogram/Running metre. As per detailed drawings and as directed byEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as rollerbearing in nylon casting and self locking catch fitted in vertical section of shutter including 5mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with allrequired screws and nuts etc, complete. With powder coating without box 181 Providing and fixing in position -------------- aluminium openable window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. b) Powder Coated 182 Providing and fixing in position -------------- aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. b) Powder Coated 183 Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. 184 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete 185 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (b) 3.00 mm thick. 186 Providing and fixing 24 gauge plain aluminium sheet on the face of door shutter including cutting to required size and fixing the screws including making good the damages if any to existing door shutter and frame etc. complete as directed or as per detailed drawing 187 Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete 188 Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete 189 Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete 190 Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. compete 191 Refixing old alluminiumpartition (Labour rate only) including necessary rubber packing, screws etc. 192 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete 193 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete 194 Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size75mmx60mm.and sill of 75mm.x25mm.and newel posts for staircases,including fabricating,fix-tures,erecting,painting the grill work with one coat of anti-corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish 195 Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing buffing to stainless steel pipe etc. complete 196 Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete 197 Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures andfastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) 198 Providing & applying Dual tone Texture Paint of Dulux make stone art ( Signature) make with one coat alkali primer, one coat above Texture paint & final coat of Ultra clean Tile shield clear coat including scaffolding, scrapping cleaning etc complete. 199 Providing & applying metalic duco paint ofapproved brand with duco primer, deco putty, finished coat of deco paint with spray painting to give appropriate finish incluing scrapping, scaffolding, cleaning etc. complete. Spec. No.As directed by Engineer-in-Charge 200 Providing & fixing M.S. cover for water tank of size 0.95 m x 0.95 mwith lock arragementthe frame of cover made up by 40 mm x 40mmx2.6mm square pipe& angle of 35x35x5 mm & cover of 35x35x5 with 2 mm thickCRC Sheet with painting etc. complete. 201 Providing and laying cast iron pipe of A class of Neco Make with socket and spiget end / flanges and cast centrifugally / vertically including specials laying pipes and back filling the trench complete including excavation 80 mm 202 Providing and laying cast iron pipe of A class of Neco Make with socket and spiget end / flanges and cast centrifugally / vertically including specials laying pipes and back filling the trench complete including excavation. 100 mm 203 Providing and making lead joints for 80mm diameter cast iron pipe line including lead and testing. Spec. No.: Bd.V.2 Page No. 549 204 Providing and making lead joints for 100mm diameter cast iron pipes line including lead and testing. Spec. No.: Bd.V.2 Page No. 549 205 Providing and making lead joints for 150mm diameter cast iron pipe line including lead and testing Spec. No.: Bd.V.2 Page No. 549 206 Providing and making flanged connection for the 80mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete 207 Providing and making flanged connection for the 100mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete. 208 Providing and making flanged connection for the 150mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete 209 Providing and fixing on walls/ ceiling/ floors, 15 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Estate Office or as directed etc. complete. 210 Providing and fixing on walls/ ceiling/ floors, 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings.remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Estate Office or as directed etc. complete. 211 Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings.remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Estate Office or as directed etc. complete. 212 Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings.remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveyingand stacking the same in Estate Office or as directed etc. complete. 213 Providing and fixing on walls/ ceiling/ floors,40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Estate Office or as directed etc. complete. 214 Providing and fixing on walls/ ceiling/ floors,50 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings.remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Estate Office or as directed etc. complete. 215 Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 10.15 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same inEstate Office or as directed etc. complete. 216 Providing and fixing on walls/ ceiling/ floors, 100 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same inEstate Office or as directed etc. complete. 217 Providing and fixing 15mm diameter water meter with non-return valve including strainer, sockets/ union nut including water meter box making locking arrangement and lock. [Without chamber]. 218 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 219 Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 220 Providing and fixing 25 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 221 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 222 Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 223 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 224 Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 225 Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 226 Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 227 Providing and fixing push cock(Self closing tap)symet type of 15mm dia.including necessary socket, testing etc. complete. 228 Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) 229 Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall 230 Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall 231 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete 232 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete 233 Providing and fixing white glazed earthenware Wash Hand Basin of 63cm x 45cm size including Bib cock stop tap brass heavy 15mm, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall 234 Providing and fixing white glazed earthenware sink (Laboratory sink) 600mmx200mmx450mm including all connection of the G.I.supply and P.V.C.waste pipes up to the outside face of the wall,cold water chromium plated screwdown bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete 235 Providing and constructing granite kitchen platform with fixing of stainless steel sink 600mmx450mm size as per detailed drawing including vertical both side polished kadappah stone 25to30mm thick supports with kadappah top 35to40mm thick and polished granite 16to20mm top with sides trips of granite at front and both sides of platform raised with two vertical granite supports 15cm height and top granite of 75x40 cm including cutting,opening for sink of required size in kadappah as well as granite etc. complete. 236 Providing and preparing kitchen otta made up from 30 mm thick and 75 cm. wide one side polished kadppa top 75 cm. wide one side polished kadappa top 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. 237 Dismanteling exisiting kitchen otta including plumbing, removing dado, plaster, sink and stacking the materials as directed with all leads, lifts, complete 238 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. 239 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe,brick masonry chamber with cast iron lid and cast iron grating for the gully trap 240 Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete 241 Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. 242 Providing and laying concrete pipes of I.S.NP. class of 100mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 243 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 244 Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 245 Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 246 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame as per approved make etc complete 247 Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. 248 Providing and fixing 6 mm thk mirror on bracket/ stud with edge polishing/Bevelling to all sides with fittings etc complete Spec. No: - As directed by Engineer in charge 249 Providing and fixing laying P.V.C. Pipe of 40 mm dia with fittings such as bends, tees, reducer, clamps, etc. including necessary excavation, trench filling etc. complete. Spec. No: - As directed by Engineer in charge. 250 Providing and fixing laying P.V.C. Pipe of 50 mm dia with fittings such as bends, tees, reducer, clamps, etc. including necessary excavation, trench filling etc. complete. Spec. No: - As directed by Engineer in charge. 251 Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polishing, cleaning etc complete. 252 Providing and fixing Orissa type white glazed earthware 575 mm water closet pan including s trap with eartenware foot rest, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 253 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0)cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 254 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe,vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 255 Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. 256 Providing and fixing 25 mm dia ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete.Spec. No: - As directed by Engineer-in-charge 257 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. 258 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 259 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 260 Providing and fixing H.D.P container one piece mouldedwater tank in 3 layer made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters. colour of water tank should be got approved from Engineer Incharge 261 Providing and fixing H.D.P container one piece moulded water tankin 3 layer made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres.colour of water tank should be got approved from Engineer Incharge 262 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stackingas directed etc. complete 263 Providing and fixing on walls/ ceiling/ floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line ifnecessary and conveying and stackingas directed etc. complete 264 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stackingas directed etc. complete 265 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stackingas directed etc. complete 266 Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line ifnecessary and conveying and stackingas directed etc. complete 267 Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. 268 Providing and fixing 10 cm PVC nahani trap with grating etc. complete 269 Providing and fixingPVC MULTI nahani trap with grating etc. complete. Spec. No: - As directed by Engineer in charge 270 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) 271 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) 272 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Heavy duty (160 Kilogram) 273 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 Kilogram) 274 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 275 Providing and making ISI Mark ferrule connection of 40mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 276 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 277 Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. 278 Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. 279 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete 280 Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. 281 Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. 282 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 283 Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks,including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved fromengineer in charge etc. complete. 284 Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks,including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved fromengineer in charge etc. complete 285 providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) 286 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc.complete 287 Providing,laying and fixing,jointing Eco-drain 200mm SN4 Nu-Drain Upvc pipes or of equivalent make,manufacture as per EN13476 or equivalent as per I.S.15328 with fittings such a bends,tees,coupler etc,jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete 288 Providing,laying and fixing,jointing Eco-drain 315 mm SN4 Nu-Drain Upvc pipes or of equivalent make,manufacture as per EN13476 or equivalent as per I.S.15328 with fittings such a bends,tees,coupler etc,jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete 289 Providing and fixing 15 mm diameter PVC approved makebib tap / Angle stop tap with flange including all accessories etc complete 290 Providing and fixing 15 mm diameter PVC approved makePillartap with flange including all accessories etc complete 291 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle ( 50 x 50x 6mm) post at 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in ( 1:4:8) cement concrete block of 45x45x45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 292 Concealed the pipe line(Approved rate) 293 Providing and constructing on sewer, B.B.Masonry circular manhole with concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C. C.1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia.etc. complete as directed by Engineer incharge. 294 Providing and fixing 15mm diameternon-return valve including sockets / union nut etc. complete. Spec. No: - As directed by Engineer in charge 295 Providing and fixing 25mm diameter non-return valve includingsockets / union nut etc. complete. 296 Providing and fixing Flexible pipe for basin outlet etc. complete. Spec. No: - As directed by Engineer in charge 297 Providing and fixing (hand shower )C.P.health faucet of Jaquar make with 8 mm dia 1 mtr long flexible tube having wall hookincluding necessary sockets/ union nut etc. complete.as directed by Engineer in charge 298 Providing and fixing (hand shower )C.P. health faucet with 8 mm dia 1 mtr long flexible tube having wall hook with approved make including necessary fitting etc. complete.as directed by Engineer in charge 299 Providingand fixingJaquar Make towel rodwith all necessaryfitting etc. complete.Spec. No: - As directed by Engineer in charge 300 Providingand fixingJaquar Make soap dish with all necessaryfitting etc. complete. 301 Providingand fixing Paper holder in toiletswith all necessaryfitting etc. complete. Spec. No: - As directed by Engineer in charge 302 Providing and fixing Jaquar make overhead shower Spec. No: - As directed by Engineer in charge 303 Providing and fixing Steen less steel Jali for Nahani trap Spec. No: - As directed by Engineer in charge 304 Providing fabricating & fixing M.S. Grating 60kg/sqm. Spec. No: - As directed by Engineer in charge 305 Repair & maintenanceof BB Chambers by increasing ht. upto 300 mm Spec. No: - As directed by Engineer in charge 306 Repair & maintenance of BB Chambers by decreasing ht. upto 300 mm Spec. No: - As directed by Engineer in charge 307 Providing and making Holes (Core cutting ) in chajjas and slab for passing the pipe line. Spec. No: - As directed by Engineer in charge 308 Providing and making Holes (Core cutting ) in U.C.R. wall for passing the pipe line. Spec. No: - As directed by Engineer in charge 309 Providing & fixing 18 mm thk plywood of approved make with Teak wood framework of size 50mm x 50mm having grid spacing at 600mmx 600mm centre to centre both ways etc complete for lift opening. 310 Providing and fixing Godrej make door clooser with all fixtures and fittingsSpec. No: - As directed by Engineer in charge 311 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) Spec. No: - As directed by Engineer in charge 312 Providing and fixing Rolling Blinds of approved make & shade with Blackout fabric& telting with chain(Ball)system with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-charge prior execution of work) Spec. No: - As directed by Engineer in charge . Brands- D Décor, MAC,Johnson 313 Providing & laying APP (Atactic Polypropylene Polymer ) modified prefabricated five layer, 3mm thick water proofing membrane, black in colour Spec. No: - As directed by Engineer in charge 314 Providing & fixing HDPE Plastic Tarpaulin200 GSM with rebatted hole to cover the roof area binding with the rope of approved colour etc. complete. Basic rate Rs 50/sqm 315 Providing & fixing Tar felt sheet over the roof area binding with the rope etc. complete. 316 P&Fchainlink50*50 mmsizeof 8 gaugewithfittingby 6mmbaretc complete.Spec. No: - As directed by Engineer in charge 317 Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. 318 Providing and supplying water tanker of filtered water from PMC upto 10,000 lit. capacity as directed by Engineer in Charge. Spec. No: - As directed by Engineer in charge 319 Providing and fixing Fixtures and fastenings of SS make to doors along with the repairs of the doors Spec. No: - As directed by Engineer in charge 320 Providing and fixing S.S. mosquito net with teak wood 0.35 x 0.10 wooden batten. Spec. No: - As directed by Engineer in charge 321 Providing & fixing H.D.P. water tank cover etc. complete. 322 Rebaring work for length of 100 to 200mm (TMT) including drilling, grounting complete. Spec. No.: As directed by Engineer in charge.,a) 8mm 323 Rebaring work for length of 100 to 200mm (TMT) including drilling, grounting complete. Spec. No.: As directed by Engineer in charge.,b) 12 mm 324 Rebaring work for length of 100 to 200mm (TMT) including drilling, grounting complete. Spec. No.: As directed by Engineer in charge.,c) 16 mm 325 P& F french doorfully glazed inbermateaksection as perdesign& drg with 5mm texture glass ply planking out side teak frame & laminate onply with floor spring etccomplete Spec. No: - As directed by Engineer in charge 326 P&Fdoor lock for French Door. Spec. No: - As directed by Engineer in charge 327 Providing and fixingcommod sheet cover NDSR 328 Providing and fixing green cloth-NDSR 329 Providing double flanged Sluice Valves conforming to IS- 14846 including worm gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges ,transportation upto departmental store ,unloading ,stacking excluding GST Levied by GOI & GOM in all respect etc. complete.Sluice Valve PN-1.0 (without bypass arrangement) 330 Providing double flanged Sluice Valves conforming to IS- 14846 including worm gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges ,transportation upto departmental store ,unloading ,stacking excluding GST Levied by GOI & GOM in all respect etc. complete.Sluice Valve PN-1.6 (without bypass arrangement) 331 Providing and fixing Inlet pipe for basin inlet etc. complete. NDSR 332 Providing & Fixing Basin waste water coupling 333 Material Shifting by truck Spec. No: - As directed by Engineer in charge 334 Mazdoor, Unskilled Heavy Male/Female Spec. No: - As directed by Engineer in charge 335 Providing Carpenter I Class Skilled Spec. No: - As directed by Engineer in charge 336 Providing Plumber with tools - Skilled Spec. No: - As directed by Engineer in charge 337 Providing welder / driller with tools - Skilled Spec. No: - As directed by Engineer in charge 338 Providing J.C.B. for cleaning, levelling, digging and miscellanous work etc. complete. Spec. No: - As directed by Engineer in charge 339 Providing and Fixing half turn/ Quarter turn of jaqaur make with necessary fittings( Flushing Cock.) 340 Providing and Fixing door fiitting for single doorbrass of CENT makeetc complete. 341 Providing and Fixing door fiitting for Double doorbrass of CENT makeetc complete. 342 Providing & fixing in position, full height partly glass panelled & partly solid partition made of treated Teak wood framework of size 50mm x 50mm having grid spacing at 900mmx 450mm centre to centre both ways & covered with 12 mm thick approved plywood on both sides of framework & finished with1mm thick laminate of approved color and texture. The framework shall be properly screwed to the walls, ceiling and floor and plywoodshall be screwed to the framework. plain Glass and texure glass of thickness 5 mm will be fixed as per design with wooden beading of size 38mm x 12 mm on both sides. Wooden beadings will befinished inthree or more coats of melamine polish (glossy/matt) with 12 mm x 6 mm groove in each panel.Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make.as per the drawing, specification as directed by the Engineer incharge etccomplete( as per Pro VC office) 343 Providing & fixing in position, full height solid partition made of C.C.Teak wood framework of size 50mm x 50mm having grid spacing at 900mmx 450mm centre to centre both ways & covered with 12 mm thick approved plywood on both sides of framework & finished with1mm thick laminate of approved color and texture. The framework shall be properly screwed to the walls, ceiling and floor and plywoodshall be screwed to the framework. plain Glass 5 mm thick and texure glass of5 mm thick will be fixed as per design with wooden beading of size 38mm x 12 mm on both sides. Wooden beadings will befinished inthree or more coats of melamine polish (glossy/matt) with 5 mm x 5 mm groove in each panel.Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make. as per the drawing, specification As directed by Engineer Incharge etccomplete. 344 Providing and fixing storage unit ( storage Runner) of W 0.45 metermade of18 mm thick plywood of approved make including shelf as per drawing and shutters both made of 18 mm thick plywood, and storage unit is finishedwith approved quality 1 mm thick laminate outer side& inner side finished with white laminate with all necessaryfittings like drawer channels, hinges, towerbolthandels, lock, safety chain, magnetic stoppers of approved make etc. melaminepolishingforexposededges As directed by Engineer Incharge etccomplete. 345 Providing and Fixing Decorative Acrylic sheet for false ceiling fixed in framework of teakwood section of 50 x 50 mm covered with teak wood beading including all necessary fixtures and fasteners, tools and plants etc. complete. 346 Providing & Fixing 6 mm thickglass for office table withnecessaryedge polish to all sides etcComplete as directed by Engineer Incharge. 347 Providing & Fixing Chemical Anchor fastner (HILTI Make) (HIT-VM 16x200) with Chemical HY 200 R etc. complete 348 Providing & Fixing Spreader forfull stall urinals etc complete 349 Providing and fixing Three waytab for laboratory etc complete. Spec. No.: As directed by Engineer in charge., 350 Providing and fixing Heavy duty Floor spring of ENOX makefor glass door etc complete. Spec. No.: As directed by Engineer in charge., 351 Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. 352 Providing & FixingCalcium Silicate boards (Hilux boards) of12mm thk for Ceiling/Wall by self drilling & tapping screws including Filling the gap between boards with joint compound & fibre tape together for seamless finishetc complete 353 Providing & FixingCalcium Silicate boards (Hilux boards) of8 mm thk for Ceiling/Wall by self drilling & tapping screws including Filling the gap between boards with joint compound & fibre tape together for seamless finishetc complete 354 Providing and fixing stage with 18mm ply with approved make. internal members using 18 mm ply at every 600mm c/c bothways .300mm depth finished with l mm thk laminate of approved make on outer side excluding the top face of stage. etc complete. Top area of stage will be considered for measurement. ( as per Dyneshwar hall of Main building) 355 Providing and fixing 4mm Thk Stilexflooring Over Stageincluding leveling the base with white cement including pasting with appropriate adhesive material cleaning the surface etc. complete ( as per Dyneshwar hall of Main building) 356 Providing and fixing flush door shutter in Double leaf 34 mm thick with teak wood bidding of size 32x12mm thk finished with 1 mm thick laminate of approved colour on both faces also including vision panel glass 5mm thick fixing with teak wood bidding on both side of vision as per given detail drawing and all necessary hardware & accessories like Hinges, D type handles on both sides, Tower bolt, Aldrops, Door stopper, as directed by Engineer Incharge etc.complete. 357 Providing and fixing flush door shutter in Single leaf 34 mm thick with teak wood bidding of size 32x12mm thk finished with 1 mm thick laminate of approved colour on both faces also including vision panel glass 5mm thick fixing with teak wood bidding on both side of vision as per given detail drawing and all necessary hardware & accessories like Hinges, D type handles on both sides, Tower bolt, Aldrops, Door stopper, as directed by Engineer Incharge etc.complete. 358 Providing and fixing flush door shutter in Single leaf 34 mm thick with teak wood bidding of size 32x12mm thk finished with 1 mm thick laminate of approved colour on both facesas per given detail drawing and as directed by Engineer Incharge etc.complete. 359 Providing and Fixing Anchar Fastner 100mm length in Wall of 10mm dia. including drilling etc complete. Spec. No.: As directed by Engineer in charge., 360 Repair work of cracks on H.D.P container Syntex or alike one piece moulded water tank using hot air gun with plastic raw wire etc. complete. 361 Supplying,providing & fixing waterproofing treatment with standard multiples of 3 kg/sqmt. Manufactured by IWL(I) ltd. Or similar as approved by engineer in charge at site with 90 micron thick HM HDPE centre core including coating the surface with multiples blown @1.2 kg/sqmt.of 90/50 grade with 10cms overlaps where required including scaffolding screwing,pasting ,capping or as As directed by Engineer in charge 362 Providing & fixing 18 mm thk.marine plywood of approved make including fixing stainless steel screw,cutting , sawing,making proper wood joinery scaffolding etc complete and As directed by Engineer in charge 363 Providing&fixing YALE make YDME 90 Digital door lock with all accessarries complete. 364 Providing and Fixing 8 mm plane glass with each side polishing and fitted on CP Brackets . 365 Rolling shutter of any size servicing , Greasing with tensioning etc complete. 366 Rolling shutter of any size servicing , Greasing with tensioning including replacing the springs etc complete. 367 Rolling shutter of any size servicing , Greasing with tensioning etc complete. With mechanical Gear 368 Providing & fixing in position, full height 75 mm thk solid partition made of Salwoodframework of size 50mm x 50mm having grid spacing at 600mmx 600mm centre to centre both ways & covered with 12 mm thick approved plywood on both sides of framework & finished with1mm thick laminate & texture paint of approved color and texture. The framework shall be properly screwed to the walls, ceiling and floor and plywoodshall be screwed to the framework. Lipping patti of BTC fixed as per design on both sidesfinishedof melamine polish (glossy/matt) .Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make. as per the drawing, specification As directed by Engineer Incharge etccomplete.(As per Deans Cabin) 369 Providing & fixing in position, full height Glass partition made of Salwoodframework of size 50mm x 50mm . The framework shall be properly screwed to the walls, ceiling and floor and plywoodshall be screwed to the framework.texure glass of thickness 6 mm will be fixed as per design with BTC beading of size 45 x 10 mmon both sides will befinished inthree or more coats of melamine polish (glossy/matt) .Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make. as per the drawing, specification As directed by Engineer Incharge etccomplete.(As per Deans Cabin) 370 Providing and fixing frosted film to existing glass as directed by Engineer Incharge etc.complete. 371 Providing and fixing 12 mm thk.plywoodfinished with 1 mm thick laminate of approved colour on one faceas per given detail drawing and with necessary Nails ,screw, fevicol etc. as directed by Engineer Incharge etc.complete. 372 Providing and fixing 18 mm thk.plywoodfinished with 1 mm thick laminate of approved colour on one faceas per given detail drawing and with necessary Nails ,screw, fevicol etc. as directed by Engineer Incharge etc.complete. 373 Providing and fixing 18 mm thk.plywoodfinished with0.8 mm white laminate on both sides as per given detail drawing and with necessary Nails ,screw, fevicol etc. as directed by Engineer Incharge etc.complete. 374 Providing and fixing frame with / without ventilator of size as specified with Burma teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete 375 Providing & fixing BTC 1 st quality Panelled doorswithbrass hingesetc complete ( shutters are as per existing design) 376 Providing & fixing BTC 1 st qualityGlazed windowwithbrass hingesetc complete ( shutters are as per existing design) 377 Providing Golden Paint atmain Building etc. Complete 378 Providing Half-round Moulding ( Full Moulding ) to 18 mm to 20 mm thick granite stone 379 Providing & Fixing Ribbed carpet by removing oldcarpet andincluding leveling the base with POP including pasting with appropriate adhesive material cleaning the surface etc. complete 380 Providing & Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete 381 Providing and fixing storage shutters made of18 mm thick plywood of approved make as per drawing andfinishedwith approved quality 1 mm thick laminate outer side& inner side finished with 0.8 mm white laminate with all necessaryfittings likehinges,handles, safety chain, tower bolt & lock of approved make etc.As directed by Engineer Incharge etccomplete. 382 Providing& Fixing storage cabinet stanadard depth 18 out to out made of 18 mm thick plywood of approved make of 2.4 mtr highincluding shelf as per drawing and shutters both madeof 18 mm thick plywood , back covered with 12 mm plywood, all edges finished with TW lipping with french polish , Storage unit is finished externally with approved quality 1 mm thick laminate including finishing inner side with 0.8 mm thk laminate& back side by two coats of french polish with necessary fixtures & fastening as per detailed design & drawing and as directed by Engineer in charge.etc.complete 383 Providing and fixing crimped with G.I.mesh and size 20 mm x 20 mm10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat,fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 384 Supply and installation of Gi spikes (height 110mm , sharpes heighted spikes at 80mm intervals width 80mm . Thickness of 3mm) for existing chainlink fencing /trepasing ,as per dwg & as directed by engineer in charge 385 Providing and casting in situ or precast tapering R.C.C.M30 Kerbs 400 mm H x 300 mm Lx100mm W finished neatly with C.M. 1:2, setting the same in C.M. 1:2, painting exposed surface of the kerbs with 2 coats ofApex paint of approved quality and colour including the required excavation in any strata and removing the excavated stuff and redoing the surface as specified and directed. Spec. No.: MORTH 409 386 Providing & fixing Reinforced precast L shaped kerb stone using 6 mm steel bars 4 number alomg the kerb length and 8 mm steel bar 500 mm c/c vertical reinforcement, M-30 grade concrete with dimensions 350 mm high, 125 mm thick with built in base of 187 mm x75 mm, including 2 numbers of 50 mm dia sleeves for services at the top of base & with top external edge with rounding of 20 mm radius in highly superior quality surface & edge finish in 1 meter length & painting as per direction of Engineer-in-charge (including excavation for kerbing, lead lift and transportation of excavated material, PCC below kerbing) As directed by Engineer In Charge 387 Providing and fixing Godrej make Drawer Lock etc complete. Spec. No.: As directed by Engineer in charge., 388 Providing S.S. rod of 25 mm thk as approved by Engineer In-Charge. 389 Providing and fixingSS Socket for curtain etc complete. Spec. No.: As directed by Engineer in charge., 390 Providing and fixing Godrej / Europa make Wordrobe Lock etc complete. Spec. No.: As directed by Engineer in charge., 391 Providing and fixing Union for 15 mm dia etc complete. Spec. No.: As directed by Engineer in charge., 392 Providing and fixing Union for 25 mm dia etc complete. Spec. No.: As directed by Engineer in charge., 393 Providing and fixing Union for 40 mm dia etc complete. Spec. No.: As directed by Engineer in charge., 394 Providing and fixing Union for 50 mm dia etc complete. Spec. No.: As directed by Engineer in charge., 395 Providing and fixing 12 mm plane glass for office table with necessary edge polishing/Bevelling to all sidesetc complete Spec. No: - As directed by Engineer in charge 396 Providing and fixing Long neck pillar cocketc complete. Spec. No.: As directed by Engineer in charge., 397 Providing and fixing in position Aluminium mosquito net shutter with stainless steel jali.The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter includingaluminium mosquito net shutter with stainless steel jali with all required screws and nuts etc, complete. With powder coating without box 398 Providing and fixing C.P. auto closing 15 mm urinal Flush cock with wall flangejaquar make(Cat.No. PRS-CHR 077)including necessary sockets/union nut etc. complete. 399 Providing and fixing C.P. auto closing 32 mm Metropole Flush valve with wall flangejaquar make(Cat.No.FLV-CHR-1095N)including necessary sockets/union nut etc. complete. 400 BASIC TEST OF CEMENT:-. Standard Consistancy, Fineness, Specific Gravity, SettingTime ( Initial & Final ), Compressive Strength, Soundness. 401 BASIC TEST OF AGGREGATE.:-Water Absorption, Specific Gravity,Impact Value, Crushing Value. 402 Sieve Analysis. 403 Abrasion value 404 Flakiness index and elongation index 405 Soundness 406 FINE AGGREGATES :-Fineness modules (Sieve Analysis), silt and clay content 407 Silt factor 408 BRICKS:-Water absorption (set of 5 bricks), Compressive strength (set of 5 bricks), Efflorescence (set of 5 bricks) 409 CONCRETE:-Compressive Strength OF C.C. Cube(Set of 3 cubes) 410 STEEL BAR TESTING :-Up to 16 mm (set of 3 bars)
Contract Date: Dec 29, 2025 Contract Value : 1.28 Crore
Boards / Undertakings / PSU No of Bidders 11
Maharashtra View Result →
50.
Defence #8502213 AOC
Repair /Maintenance Of Water Supply Installation Including Pumps, Starter, Panel Distribution At Icgs Kakinada, Malkapuram, Jetty Complex And Fire Alarm System And Fire Fighting System Including Allied Works At Icgs Malkapuram Under Ge(I)(Cg)Vizag; 1 Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, in cable tench etc. n exc 10 sqm on plan and getting out soft / loose soil complete all as directed. 2 Returning, filling in incl spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. 3 Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. 4 M & L for sand cushioning under trenches as in cable protection complete all as specified and directe.(Note: Punned thickness shall measured for payment purpose) 5 Supplying and laying reinforced precastconcrete cable cover, Class LV, Type I,flat,size 250mm x 150mm x 40mm complete all as specified & directed. 6 Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 7 Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 8 Taking up or down 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 9 Taking up or down 50 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 10 Taking up or down 80 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 11 Taking up or down 100 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 12 S&F 20mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 13 S&F 25mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 14 S&F 40mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 15 S&F 50mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 16 S&F 80mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 17 S&F 100mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 18 S&F90 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 19 S&F110 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 20 S&F50 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 21 S&F40 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 22 S&F25 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 23 S&F 32 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 24 S&F 40 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 25 S&F 50 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 26 Supply and laying in repair 32mm bore dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 27 Supply and laying in repair 40mm bore dia High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 28 Supply and laying in repair 50mm bore dia High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 29 Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 sq mm 4 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 30 Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 3.5 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 31 S&F high quality PVC flexible pipe of 20mm dia complete all as specified and directed. 32 S&F in repair cast iron Non Return valve 150 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 33 S&F in repair cast iron Non Return valve 100 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 34 S&F in repair cast iron Non Return valve 80 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 35 S&F in repair cast iron Non Return valve 25 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 36 S&F in repair cast iron Foot valve of 80 mm dia confirming to IS 4038 1986 complete all as specified & directed 37 S&F in repair cast iron Foot valve of 100 mm dia confirming to IS 4038 1986 complete all as specified & directed 38 S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 39 S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 40 S&F in repairs Disc Filter (Plastic Body) for garden sprinkler system made of durable non-corrosive polymer suitable for water filtration as exisitng complete all as specified and directed. 41 Supply and laying and testing submersible flat, PVC insulated,heavy duty, copper electric cable 6 Sqmm 3 core screened pvc bedded, 1100 Voltgrade laidin borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed 42 Supply and laying and testing submersible flat, PVC insulated,heavy duty, copper electric cable 4 Sqmm 3 core screened pvc bedded, 1100 Voltgrade laidin borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed 43 Taking down carefully Exhaust fan of Squirrel cage induction motortype 300mm Sweep from existing location carrying out rewinding with super enamelled copper wire, replacement bearing, painting, cleaning and servicing and refixing in existing / new location including making electric connection with PVC insulated copper conductor cable from fan to ceiling rose complete all as specified and directed. 44 M & L for preparation of surface of pump/ motor upto 50 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 45 M & L for preparation of surface of pump/ motor upto 10 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 46 M & L for preparation of surface of pump/ motor upto 05 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 47 Supply and fix in repairs 150 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 48 Supply and fix in repairs 100 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 49 S&F in repair 80 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 50 S & F in repairs50 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 51 S & F in repairs40 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 52 S & F in repairs25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 53 S & F in repairs20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 54 S & F in repairs15 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 55 M & L for Disconnecting of a mono-block / submercible pump of capacity up to 5 HP from all electric and water supply connection, lifting from existing position as required, transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 56 M & L for Disconnecting of a mono-block / submercible pump pump of capacity up to 10 HP from all electric and water supply connection, lifting from existing position as required,transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 57 M & L for Disconnecting of a mono-block / submercible pump of capacity up to 50 HP from all electric and water supply connection, lifting from existing position as required, transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 58 S & F in repair Direct-On-Line (DOL) starter, Single phase for submersible pump control complete as specified and directed. 59 S&F in repair Direct-On-Line (DOL) starter, Three phase for submersible pump control complete as specified and directed. 60 S&F in repair Star Delta starter for Motor Pump for up to 5 HP Capacity including 3 phase prventer complete all as specified and as directed . 61 Dismantling damage and broken valve chamber of size 1200x1200x900mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall, 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 62 Dismantling damage and broken valve chamber of size 900x900x900mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 63 Dismantling damage and broken valve chamber of size 750x750x750mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 64 Dismantling damage and broken valve chamber of size 450x450x450mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 65 M & L for cleaning of UG Sump capacity upto 20KL at CG Enclave kakinada by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 66 M & L for cleaning of UG Sump capacity upto 225KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 67 M & L for cleaning of UG Sump capacity upto 100KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 68 M & L for cleaning of UG Sump capacity upto 50KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 69 S&F in repairs MCCB 200 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 36kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 70 S&F in repairs MCCB 100 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 16kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 71 S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 16kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 72 Material and labour for taking sample of water in sterlised bottles from UG Sump for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories:(i) Physio Chemical Analysis of Water (Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride)(ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Govt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample 73 M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth strip of 25 x 4 mm size upto 7.50 m bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 40 mm (light grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.] 74 M&L in repair of solar type kitchen chimany after dismentaling from existing location of building , checking of motor, servicing/overhauling of motor, replacement of warn out parts like filters, motors, light bulbs, switches, ducts and cowls, reinstallation of solar chimany and refixing in same position after completion of work and testing completeall as specified and directed. 75 M & L for repairing of broken earthing pits chamber with PCC (1:3:6) type C-1with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipeincluding Painting with White cement colour (Red/Green/Yellow) ofearthingpitsof diffirent colour as per Earthing type (Chemical/LighteningProtection and Conventional ) complete all as specified and directed. 76 M & L for repairing of Broken Foundations of Monolock Pumps and LT Panel Board including raising of heights of panels as possible at site with PCC (1:3:6) type C-1 and painting the foundations with cement base paint or as per existing pattern complete all as specified and directed. 77 Material and labour for repairing of water supply starter panel board internally, detecting fault in control wiring, contractor, relay, time delay and connecting block including replacement of worn out spare parts with new items as per existing make and specification, Testing and commissioning with entire satisfaction of Engr-in-charge including its rewiring and replacement of defective appliances with new parts and testing complete all as specified and directed. (Notes : Spare partsshall be Measured & Paid separately under relevant supply only items) 78 Supply only Contactor ML-3 / ML-4, 450 Volts complete all as specified and directed. 79 Supply only Indicating lamp (set of 3) complete all as specified and directed. 80 Supply onlySingle phase preventor complete all as specified and directed. 81 Supply only Ameter 0-100Amps with suitable CTs complete all as specified and directed. 82 Supply onlyVoltmeter 0-500 volts with suitable PTs complete all as specified and directed. 83 Supply only Relay 30-40 Amp complete all as specified and directed. 84 Supply only Timer for starter complete all as specified and directed. 85 Supply only Selector switch RYB complete all as specified and directed. 86 Supply only Copper conductor flexible wire 40/0.0076 complete all as specified and directed. 87 Supply only Frequency meter 50Hz complete all as specified and directed. 88 Supply only Phase reverse preventor complete all as specified and directed. 89 Supply only MCCB 250 Amps 4 Pole 36 KA adjustable type for earth fault and overload current complete all as specified and directed. 90 M & L for repair and calibration of the mechanical water level indicator installed on the underground (UG) sump including inspection, servicing, replacement of damaged components such as dial mechanism, float, pulley system, wire rope, and realignment as necessary to ensure accurate and smooth functioning and applying two coats of synthetic enamel paint complete all as specified and directed. 91 Supply and laying of ductile iron pipe of size 100mm dia with spigot and socket end, centrifugaly cast, pressure class K-9 laid in trenches on surface / over masonary pillar and connection to old or new positionincluding taking up / down existing unserviceable pipe complete all as specified and directed. 92 Supply and fixing DI specials fittings of any type, radius and angle complete all as specified and directed 93 Supply and fixing in repair UPVCball valve of size 50 mm dia complete all as specified 94 Supply, install, testing (as per IEC 61439-I) and commisioning of LT feeder piller box of suitable size as per relevant IS, CPRI approved, cubical floor mounted Indoor type, factory made, totally enclosed, dust and vermin proof made out of 2.0mm thick MS sheet duly powder coated both side in and out, having suitable locking arrangments both at front and rear sides, duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500V, 50Hz AC supply, including hibling, cable entry boxes, cable gland, suitable angle iron framed support (bottom portion of the panel), grouted in foundation in PCC 1:2:4 type B1 using 20mm graded stone aggregates including taking down old unserviceable panel complete all as specified and as directed housing and with the following switchgears(for Pump House)Incomming:-(a) MCCB4Pole, 415V, 63 Amps, 25KA - 01NosOutgoing: (a) MCB, TP, 415V, 32 Amps, 10KA - 01 Nos(b) MCB, TP, 415V, 20 Amps, 10KA - 01 Nos(c) MCB, SPN, 415V, 20 Amps, 10 KA - 02 Nos(d) 7.5HP, 3Ph star-delta Motor starter with Main, Star & Delta Contactor, Thermal Over load relay, Star-delta timer(electronic adjectable), Control Transformer, Dry run protection, Phase failure relay , star/stop push botton - 01 Set(e) 10HP, 3Ph star-delta Motor starter with Main, Star & Delta Contactor, Thermal Over load relay, Star-delta timer(electronic adjectable), Control Transformer, Dry run protection, Phase failure relay , star/stop push botton - 01 (f) Digital volt meter & ammeter -02 Set(g) Phase indicator lamps (RYB) set of 3- 02set 95 Comprehensive maintenance and repair of addressable/conventional networked fire alarm systems installed at CGC OTM, Sports Complex, Pandya, Kalinga, Multi-level parking, C1, C2, B9/C3, B10 & B11 buildings within ICGS Complex, Malkapuram. The scope includes routine, preventive, and breakdown maintenance, testing, inspection, cleaning, and calibration of all system components to ensure safe and efficient operation. Thorough checking of fire alarm panel with control units, loop controllers, and power supply modules and connected items as per OEM guidelines shall be done. Replacement of spare parts is included in quoted rates. Minor spares must be provided by the contractor at no extra cost, and major parts shall be measured and paid for separately under respective item of BOQ. A checklist for the fire alarm system shall be prepared for each building and submitted for records complete all as specified and directed. Note :(i)Contractor shall visit the site before quoting the rate. (ii)A supervised fire drill shall be carried out as per user requirement. (iii)A Service Engineer will report to site, within 4 – 8 working hours, from the Time of Complaint Logging.(iv)Training to the User Team will be given Half –Yearly based on Client requirement. 96 Comprehensive maintenance and repair of fire fighting systems consisting of main pump (diesel/electric), jockey pump, control panels, fire hydrants, landing valves, gate valves, NRVs, instrumentation, and associated piping and cabling networks, fire panel installed at CGC OTM Sub-Station, Pandya Bldg, 96Qtrs Pump House & Main Pump House within ICGS Complex, Malkapuram. The scope includes routine, preventive, and breakdown maintenance, testing, inspection, cleaning, and calibration of all system components & panels to ensure safe and efficient operation. Thorough checking of pump performance, controller settings, suction/discharge lines, and valve operations as per OEM guidelines shall be carried out. Replacement of spare parts is included in quoted rates. Minor spares must be provided by the contractor at no extra cost, and major parts shall be measured and paid for separately under respective items of BOQ. A checklist/logbook for the fire fighting system shall be prepared for each building and submitted monthly for records, complete all as specified and directed.Note :(i) The contractor shall visit the site and inspect the fire fighting system before quoting the rate.(ii) A supervised fire drill and hydrant test shall be conducted as per user requirement and recorded.(iii) A Service Engineer shall report to the site within 4–8 working hours from the time of complaint logging.(iv) User training on fire pump operation, valve systems, and emergency procedures shall be provided half-yearly, based on client requirement.(v) The entire system shall be checked and kept in Auto mode with required pressure levels as per OEM standards, wherever applicable. 97 M & L for preparation of exposed steel surface of existing priming tank / LT Panel /pipeincluding removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 98 Supply only MS ERW pipe of 150 mm dia, 5.4 mm thickness complete all as specified and directed. 99 Supply only MS ERW pipe of 100 mm dia, 5.4 mm thickness complete all as specified and directed. 100 Supply only MS ERW pipe of 80 mm dia, 4.84 mm thickness complete all as specified and directed. 101 Supply and fixing in repair of damaged/defective/unserviceable fire brigade inlet connection 4 way complete all as specified and directed. 102 Supply and fixing in repair of damaged/defective/unserviceable fire brigade inlet connection 2 waycomplete all as specified and directed. 103 Supply and fixing in repair fire hydrant landing valve GM type A single outletof 63 mm dia withnew hydrant confirming to IS 5290 with PVC blank cap and MS or GI chaincomplete all as specified and directed. 104 Supply and fixing in repair fire hydrant landing valve GM type B ( Double head outlet) of 63 mm dia withnew hydrant confirming to IS 5290 with PVC blank cap and MS or GI chaincomplete all as specified and directed. 105 S&F in repair damaged /defective/unserviceable ABS plastic 3/4 shut off nozzle suitable for 19/20 mm hosecomplete all as specified and directed. 106 S&F in repair presure gauge glycerine filled with 15 mm inlet connection dial size 100 mm of pressure range 0 to 14Kg/cm2 with 15mm isolation valve with G.I. nipplecomplete all as specified and directed. 107 S&F in repair presure gauge glycerine filled with 15mm inlet connection dial size 200 mm of pressure range 0to 21Kg/cm2 with 15mm isolation valve with G.I. nipple complete all as specified and directed. 108 Repair/Servicing of fire hydrant landing valve type A/B of 63 mm dia, including spindle thread machine, washers replacementmnt, checkout, packing serving complete to arrest leakage and proper function of valvecomplete all as specified and directed. 109 S&F in repair CP hose reel 15 m complete all as specified and directed. 110 S&F in repair fire fighting RRL hose pipe of 63mm, ISI marked, IS 63 (type A),15m long fitted with male and female gun metal coupling ISI marked, IS 903 complete all as specified and directed. 111 S&F in repair gunmetal branch pipe with long nozzle suitable for 63 mm dia RRL hose pipe, ISI marked, complete all as specied and directed. 112 Supply and Fix in repair outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600mm X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrantvalve etc and must have the legend FIRE HOSE painted prominently in graphic style complete all as specified and directed. 113 S&F in repair 4 mm thick sheet glass for fire hose boxes of size 0.20 x 0.20 m complete all as specified and directed. 114 S&F in repairhose reel drum of 20 mm dia and 30 mtr length hose pipe conformingto IS-5132 including gun metal nozzle suitable valve complete all as specified and directed. 115 Supply, install, testing and commissioning of pressure switch with set point up to 7.5 Bar, suitable for use in fire fighting and water supply systems. The pressure switch shall be compact, robust, and enclosed in a weatherproof IP65-rated housing, equipped with SPDT contacts rated for standard control circuits. The unit shall be suitable for vertical or horizontal mounting and compatible with water and air media. It shall include necessary accessories for secure installation and shall be calibrated and tested for reliable cut-in and cut-out pressure control including taking down old unserviceable switch complete all as specified and directed. Make: Danfoss or equivalent approved by GE. 116 Repair and maintenance of fire service main pump, multi-stage, horizontal split casing type, with a capacity of up to 100 HP and a head of 90 metres, operating at 1450 RPM, and coupled with a diesel engine of up to 100 HP. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, and charging lubricants to ensure smooth operation. It also includes servicing of the diesel engine by replacing filters, lubricant oil, and other defective parts including coupling, oil and air filters, servicing of radiator, replacement of exhaust gasket, and replacement of diesel supply and return pipes from the tank to the engine. Battery leads shall be replaced as required and the charging circuit shall be checked and made fully functional. The complete pump set, including base frame and associated pipelines inside the pump room, shall be cleaned, surface-prepared, and two coats painted with an approved shade of synthetic enamel paint complete all as specified and directed.Note: Pipelines and pump shall be painted in standard red colour as per Fire Fighting Manual and relevant IS codes, using synthetic enamel paint after proper surface preparation. 117 Repair and maintenance of multi-stage fire service main pump of horizontal split casing type, rated up to 100 HP and delivering a head of 90 metres, operating at 1450 RPM and coupled with an AC induction motor up to 100 HP capacity. The work includes complete servicing of the pump set by replacing worn-out/unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts. Lubricants shall be charged as required to ensure smooth operation. The entire pump set, including base frame and associated pipeline network inside the pump room, shall be thoroughly cleaned, surface-prepared, and painted with two coats of approved shade synthetic enamel paint. Final testing and trial run shall be carried out to confirm smooth and leak-free performance complete all as specified and directed by Engineer-in-Charge.Note: Pipelines and pump shall be painted in standard red colour as per Fire Fighting Manual and relevant IS codes, using synthetic enamel paint after proper surface preparation. 118 Repair and maintenance of fire service jockey pump, multi-stage, horizontal split casing type, with a discharge capacity of up to 180 LPM at 90 metres head, operating at 2900 RPM and coupled with an AC induction motor of up to 5.5 HP. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts, and charging of lubricants to ensure smooth and efficient operation. The entire pump set, including base frame and associated pipeline network inside the pump room, shall be cleaned, surface-prepared, and painted with two coates of synthetic enamel paint of standard fire-fighting red colour over one coat of primer, as per fire safety norms and relevant IS codes complete all as specified and directed. 119 Repair and maintenance of fire service terrace/booster/priming pump, multi-stage, horizontal split casing type, with a discharge capacity of 900 LPM at 36 metres head, operating at 2900 RPM and coupled with an AC induction motor. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts, and charging lubricants to ensure smooth and efficient operation. The entire pump set, including base frame and associated pipelines within the pump room, shall be cleaned, surface-prepared, and painted with synthetic enamel paint of standard fire-fighting red colour, as per relevant fire safety norms and IS standards complete all as specified and directed. 120 S&F in repair ball valve with brass spindle of 25mm dia complete all as specified and directed. 121 S&F in repair ball valve with brass spindle of 50 mm dia complete all as specified and directed. 122 Supplying, installing, testing and commissioning of 150mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. (Makes: Audco/Kirloskar/Honeywell) 123 Supplying, installing, testing and commissioning of 100mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. Approved makes: Audco/Kirloskar/Honeywell. 124 Supplying, installing, testing and commissioning of 80mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. Approved makes: Audco/Kirloskar/Honeywell. 125 Supply and fixing in repair approved quartezoid bulb 15 mm dia sprinkler pendent type , IS 15106 chrome plated crossette plate, with temperature rating 68 degree with universal deflector as approved by T.A.C complete with all necessary connections complete all as specified and directed. 126 Supply Only analogue addressable multisensor detector (Photo + Thermal) with base with galvanised steel, back box and all mounting accessories complete all as specified and directed. 127 Supply Only analogue smoke detector with all mounting accessories complete all as specified and directed. 128 Supply only addressable Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessoriescomplete all as specified and directed. 129 Supply onlyaddressable Riser Modules with mounting accessoriescomplete all as specified and directed. 130 Supply onlyaddressable control relayModulewith 230 V 2 A where required in a junction box with mounting accessoriescomplete all as specified and directed. 131 Supply onlyaddressable riserModulefor Hooter in ajunction box with mounting accessoriescomplete all as specified and directed. 132 Supply onlyElectronic Hooterinclude provide MS box suitable size for concealing the hooter in the wall mounting accessories complete all as specified and directed. 133 Supply only Conventional Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessoriescomplete all as specified and directed. 134 Supply onlyElectronic Hooterinclude provide PVC box suitable size for concealing the hooter in the wall mounting accessories complete all as specified and directed. 135 Supply only EST network card for addressable fire alarm control panel complete all as specified and directed. 136 Supply only EST make, power supply unit for EST 3 addressable fire alarm control panel complete all as specified and directed. 137 Supply and fixing of micro processed based upto 16 zone conventional fire alarm control panel with standards NFPA 72 can operate up to 30 detectors per zone, Board should consist of RS 485 ,2 programmable relay, support port for class B style input devices with networkable ability the above price includes two batteries, installations, commissioning, and networking with main integration network including taking down old unserviceable panel complete all as specified and directed. 138 S&F in repair of manual call point glass/fibre flip cover transparent typefixed to surface mounted MCP complete all as specified and directed.
Contract Date: Dec 27, 2025 Contract Value : 47.15 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Andhra Pradesh View Result →
TenderDetail
Loading tenders